Loading...
BPOL2017-016678-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: POOL/PRIVATE T4,tr44QurRrw DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BPOL2017-0166 Property Address: ' 52340 ROSS AVE APN: 767670025 Application Description: MADISON / SAFI / (4) WATER FEATURES Property Zoning: Application Valuation:' $8,700.00 Applicant: DESERT MIRAGE POOLS & SPAS P 0 BOX 10050 INDIO, CA 92202 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 12/27/2017 Owner: SAFI 52340 ROSS AVENUE LA QUINTA, CA 92253 Contractor: DESERT MIRAGE POOLS & SPAS P 0 BOX 10050 INDIO, CA 92202 (760)702-9222 Lic. No.: 999928 ------------------------------ -- -1a------------- ------------------------------- LICENSED CONTRACTOR'S DECLA TION I hereby affirm under penalty of perjury that I am license under ro isions of Chapter 9 (commencing with Section 70001 of Division 3 of the B iness a d rofessions Code, and my License is in full force and effect. 11 License Class: C53 License No.: 999928 Il Date: L !Z -V-17 , Contractor: OWNER -BUILDER ECI fA ON I hereby affirm.under penalty of perjury that I m exem t from the Contractor's State License Law for the following reason (Sec. 7031\., Busin ss and Professions Cade: Any city or county that requires a permit to construct, Iter,)mprove, demolish, or repair any structure, prior to its issuance, also requires th licant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of, the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption..Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: l (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury thatthere is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificat= of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. - I have and will maintain workers' compensation insurance,'as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy numbe are: Carrier: STATE COMPENSATION INSURANCE FUND Policy Numb 125416 I certify that in the performance of rhe work fo hffto is issued, I shall not employ any person in any manner so as to beco a suorkers' compensation laws of California, and agree thi t, if I sho beo the workers' compensation provisions of Section 3700 of th aboforthwith comply with those provisions. Date: .- -Applicant: WARNING: FAILURE TO SECURE WORKERS' ,APE ATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRI IhAL P NALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,[100).. PADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED F I ECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT . IMPORTANT: Application Is hereby made to tha Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit Issued as a result of this application , the owner-, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the :ity of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit,of cessatiop of work for 180 days will subject permit to cancellation. ' ' // I. I certify that I have read this application and state thatthe above info I agree to comply with all city and county ordirances and state laws a construction, and hereby authorize representa5ves of this city to en u above-mentioned property for inspection purposes. Date: .12-77-17 Signature (Applicant or Agent): Date: 12/27/2017• Application Number: BPOL2017-0166 Owner: Property Address: S2340 ROSS AVE SAFI APN: 761670025 52340 ROSS AVENUE Application Description: MADISON / SAFI / (4) WATER FEATURES LA QUI NTA, CA 92253 Property Zoning: Application Valuation: $8,700.00 Applicant: Contractor: DESERT MIRAGE POOLS & SPAS DESERT MIRAGE POOLS & SPAS P 0 BOX 10050 P O BOX 10050 INDIO, CA 92202 INDIO, CA 9220 (760)702-9222 ---------------------.------------------------------------------------------------------------ Llc. No.: 999921= Detail: (4) WATER FEATURES THROUGHOUT HOME + ASSOCIATED LIGHTING AND SANITATION EQUIPMENT. (2) AT FRONT ENTRY, (1) AT SOUTH SIDE YARD, AND (1) AT FRONT YARD NEAR DRIVEWAY. WORK COMPLETED WITHOUT PERMIT OR INSPECTION. SEE POOL/SPA PERMIT [BPOL2017-0014] FOR INFORMATION AND NOTES PERTAINING TO THIS PERMIT. [JHA ENGINEERING] 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT DETACHED SPA/WATER FEATURE/OTHER 101-0000-42404 0 $195.05 DESCRIPTION ACCOUNT QTY AMOUNT SWIMMING POOL/SPA 101-0000-42404 0 $195.05 DESCRIPTION ACCOUNT QTY AMOUNT WATER FEATURE PC 101-0000-42600 0 .$98.83 Total Paid for POOL / SPA: $488.93 . DESCRIPTION ACCOUNT. QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00, DESCRIPTION ACCOUNTQTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 TOTALS: $i'n #City of La Quin'ta Building 8t Safety Division �l i06 78-495 Calle Tampico ' La Quinta, CA 92253 - (760) 777-701.2 Building Permit Application and Tracking Sheet Permit- pp(, Zp Project Address: 5 L -3 40 dS U Owner's Name: A. P. Number. Address: .,S-2-3 Q Legal Description: P f G Ur e 3 Contractor. a City, ST, Zip: Telephone: Address:_ C -84 Project Description: City, ST, Zip: Ovoch& PAZZ3 V 01 Lf Telephone / «( State Lic. # : City Lic. #.- , 7 Arch.,Engr., Designer. l / 2 ' e Address: S , , _ IYCAJm City, ST, Zip: 1/ O e Tel hone: epse�:Y::�r�:yy,.....,.. State Lic. #: •«'_ ..:. «�:,�` c^`« -.. ' `<"' '' '" a �" Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: '��Pere Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: 0 70L 9,72ZEstimated coc- Value of Project: APPLICANT: DO' NOT WRITE BELOW THIS UNE # Submittal Req -d Recd TRACKING PERMIT FEES Plan Sets Pian Check submitted Item Amount Structural Caics. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance. Title 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2`' Review, ready for correctionsfissue Electrical Subcontaetor Ust Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. I-LO.A.'Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for correctionsfissue Developer Impact Fee Planning Approval Called Contact Person A.I-P.P. Pub. Wks. Appr Date of permit issue School Fees, Total Permit Fces OFFiGac � • • , -cve►- REt;EIVEL) DEC 2 0.2017 CITY OF ISA OUINTA COMMUNITY DEVELOPMENT Bit o .50L -to C:,V�ou-T f ` I 4,3„ 30, —t--- `5 Ue ve E-9 _ - \ \f f , - ;' E-3 Cir :� � I •�- , � �) �� , � --- ' � � � 9- til►, All • .� � T il A , -7..r' E-10 - 'f J RECEIVED DEC 2 6 2017 CITY OF LA OWNTA COMMUNITY REVEL OPYMMT Gw Gaudet Design Group Landscape Architecture 2109 Stoner Avenue West Los Angeles, California 90025 310.828,4908 310.828.4906 Fax SC w 0 3970 E-5 ` November2017 Nerera3ah U•T 11-02-16\P SOF r.Ati�Eo CONNECTIONS DESIGN FOR DIRECT BURIAL, ORAPPROVED EQUIVALENT. ONLY FULLY ENCAS ULATED WATERPROOF CONNECTORS RATED FOR DIRECT BURIAL WILL BE WIRES ON THE BACK OF POSTS, TREES AND OTHERELEMENTS AVAILABLEFOR THIS PURPOSE. CABLE MOUNTED TO TREES SHALL BE THE SMALLEST GAUGE WIRE POSSIBLE DIAGRAMMATIC AND IS INTENDED TO SHOW GENERAL FIXTURE LOCATION AND UTILITIES. THE CONTRACTOR ISRESPONSIBLETHE FOR NECESSARY LINEHOWVOLT) AND LOW 00 a yx , E 2 E5 MOUNTING TO TREES SINCE THE STAPLE WILL CUT THE WIRE AS THE TREE GROWS. LEAVE A SLIGHT SLACK IN THE CABLE TO ALLOW FOR TREE GROWTH. MAKE STANDARDS: LOAD SHALL NOT EXCEED 80% OF THE TRANSFORMER RATING 240 -WATTS ON A CONNECTIONSIN MINI -J -BOXES WITH WIRE NUTS PROVIDED BY THE MANUFACTURER. I- 300 -WATT TRANSFORMER). LOAD IS DETERMINED BY FWTURE LAMP LOAD AND DISTANCE TO THE TRANSFORMER, •\ � E 5 KRYLON PRIMER GREY OR BLACK TO MATCH THE TREE COLOR IS RECOMMEMDED. i r'""` y •N GUARANTEE: UPON COMPLETION AND ACCEPTANCE OF THE WORK, THE CONTRACTOR SHALL PROVIDE , IRRIGATION WATER. INSTALL TRANSFORMERS 12' ABOVE FINISH GRADE AND LEVEL. ALL A GUARANTEE FOR ALL WORKMANSHIP AND EQUIPMENT FURNISHED AND INSTALLED BY , THE CONTRACTOR FOR A PERIOD OF ONE YEARFROM THE DATE OF ACCEPTANCE. INSTALLATION: FIRMLY AFFIXED TO MOUNTING SURFACE. ALL JUNCTION BOXES AND OTHER WARRANTY WORK SHALL BE PERFORMED AT NO COST TO THE OWNER AND SHALL BE THE CONTRACTOR IS TO VERIFY THE SITE, WALKWAYS, STAIRS, PLANTINGS, BUILDINGS, AND OTHER ELEMENTS, M NTS, WHICH AFFECT THE INSTALLATION. THE CONTRACTOR SHALL EQUIPMENT SHALL BE UL APPROVED FOR WET LOCATIONS. INSTALL TRANSFORMERS SHALL BE INSTALLED IN COMPLIANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND , VERIFY THE EXISTING ELECTRICAL SERVICE, DISTRIBUTING AND PANEL LOCATIONS. tHE CONTRACTOR SHALL DETERMINE THE NECESSARY PANELS, BREAKERS, CONDUIT, WIRE, APPLICABLE CODES. ALL TRANSFORMERS SHALL BE CONNECTED TO GFI RATED DUPLEX OUTLETS IN WET LOCATION RATED ELECTRICAL OXES. TRANSFORMERS (EXCEPT 4 WIRING DEVICES INVOLVED WITH THIS INSTALLATION AS DESIGNED. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY COMPONENTS AND ACCESSORIES TO COMPLETE THE STAINLESS STEEL) CAN BE PAINTED TO MATCH THE BURRO UNDING SURFACES. TRANSFORMERSSHALL BE CLEARLY AND NEATLY MARKED WITH WATER PROOF MARKING INSTALLATION AS DESIGNED. INDICATING THE TRANSFORMER NUMBER, CIRCUIT TO WHICH THE TRANSFORMER IS 1 LUMINATE ADDRESS MBERS d 27 LIGHTING FIXTURES.THE MINIMUM ALLOWABLE CABLE SIZE FOR DIRECT BURIAL IS AND FOCUS ALL EQUIPMENT TO THE SATISFACTION OF THE LANDSCAPE ARCHITECT AND OWNER. h` iy f 12 -GAUGE MULTI -STRANDS. INSTALL CABLE ALONG THE EDGE OF HARDSCAPE AND MOW i t' STRIPS WHENEVER POSSIBLE. MINIMUM CABLE DEPTH IS 12 -GAUGE MUL TISTRANDS. FDOL RE LOCATIONS: HK USA LIGHTING GROUP INSTALL CABLE ALONG THE EDGE OF HARDSCAPE AND MOW STRIPS WHENEVER POSSIBLE. MINIMUM CABLE DEPTH IS 8'. THE CONTRACTOR SHALL INSTALL 1' PVC VERIFY EXACT LOCATION WITH THE LANDSCAPE ARCHITECT, OR THE OWNER BEFORE STARTING THE WORK. ALL FIXTURES SHALL BE NEW, UNUSED CONDITION. EQUIPMENT DARK BRONZE CHASE LINE SLEEVES WITH SWEEP CORNERS FOR ANY CABLE RUN UNDER HARDSCAPE OR DIFFICULT TO ACCESS AREAS SUCH AS AT GRADE AND HIGH IMPACT AREAS SUCH AS RECEIVED DEC 2 6 2017 CITY OF LA OWNTA COMMUNITY REVEL OPYMMT Gw Gaudet Design Group Landscape Architecture 2109 Stoner Avenue West Los Angeles, California 90025 310.828,4908 310.828.4906 Fax SC w 0 3970 E-5 ` November2017 Nerera3ah U•T 11-02-16\P SOF r.Ati�Eo CONNECTIONS DESIGN FOR DIRECT BURIAL, ORAPPROVED EQUIVALENT. ONLY FULLY ENCAS ULATED WATERPROOF CONNECTORS RATED FOR DIRECT BURIAL WILL BE WIRES ON THE BACK OF POSTS, TREES AND OTHERELEMENTS AVAILABLEFOR THIS PURPOSE. CABLE MOUNTED TO TREES SHALL BE THE SMALLEST GAUGE WIRE POSSIBLE DIAGRAMMATIC AND IS INTENDED TO SHOW GENERAL FIXTURE LOCATION AND UTILITIES. THE CONTRACTOR ISRESPONSIBLETHE FOR NECESSARY LINEHOWVOLT) AND LOW 00 a yx , (12 -VOLT) WORK 70 COMPLETE THE LIGHTING DESIGN AS SHOWN. E5 MOUNTING TO TREES SINCE THE STAPLE WILL CUT THE WIRE AS THE TREE GROWS. LEAVE A SLIGHT SLACK IN THE CABLE TO ALLOW FOR TREE GROWTH. MAKE STANDARDS: LOAD SHALL NOT EXCEED 80% OF THE TRANSFORMER RATING 240 -WATTS ON A CONNECTIONSIN MINI -J -BOXES WITH WIRE NUTS PROVIDED BY THE MANUFACTURER. I- 300 -WATT TRANSFORMER). LOAD IS DETERMINED BY FWTURE LAMP LOAD AND DISTANCE TO THE TRANSFORMER, •\ iL r S TRANSFORMERS SHALL BE LOCATED IN INCONSPICUOUS LOCATIONS USING PLANT KRYLON PRIMER GREY OR BLACK TO MATCH THE TREE COLOR IS RECOMMEMDED. ,y IEA 11'i.115 GUARANTEE: UPON COMPLETION AND ACCEPTANCE OF THE WORK, THE CONTRACTOR SHALL PROVIDE , RECEIVED DEC 2 6 2017 CITY OF LA OWNTA COMMUNITY REVEL OPYMMT Gw Gaudet Design Group Landscape Architecture 2109 Stoner Avenue West Los Angeles, California 90025 310.828,4908 310.828.4906 Fax SC w .. 0 3970 ^� November2017 Nerera3ah U•T 11-02-16\P SOF r.Ati�Eo .. N63d 2'4 91 WELL AS THE INSTALLATION OF LOW VOLTAGE TRANSFORMERS AND DIRECT BURIAL CABLE NECESSARY TO COMP COMPLETE THE PLAN AS SHOWN. THIS LIGHTING PLAN IS CONNECTIONS DESIGN FOR DIRECT BURIAL, ORAPPROVED EQUIVALENT. ONLY FULLY ENCAS ULATED WATERPROOF CONNECTORS RATED FOR DIRECT BURIAL WILL BE WIRES ON THE BACK OF POSTS, TREES AND OTHERELEMENTS AVAILABLEFOR THIS PURPOSE. CABLE MOUNTED TO TREES SHALL BE THE SMALLEST GAUGE WIRE POSSIBLE DIAGRAMMATIC AND IS INTENDED TO SHOW GENERAL FIXTURE LOCATION AND UTILITIES. THE CONTRACTOR ISRESPONSIBLETHE FOR NECESSARY LINEHOWVOLT) AND LOW ACCEPTED. TAPED CONNECTIONS ARE NOT ACCEPTABLE. - TO MAINTAINII.SVOLTS AT THE FIXTURE. USE NYLON C -CLIPS WITH A SINGLE STAINLESS STELL CREW WHEN ATTACHING CABLE TO TREES. DO NOT USE STAPLES WHEN (12 -VOLT) WORK 70 COMPLETE THE LIGHTING DESIGN AS SHOWN. TRANSFORMERS: TRANSFORMERS SHALL BE SPJ, VISTA, FX, OR OTHER APPROVED EQUIVALENT. MAXIMUM MOUNTING TO TREES SINCE THE STAPLE WILL CUT THE WIRE AS THE TREE GROWS. LEAVE A SLIGHT SLACK IN THE CABLE TO ALLOW FOR TREE GROWTH. MAKE STANDARDS: LOAD SHALL NOT EXCEED 80% OF THE TRANSFORMER RATING 240 -WATTS ON A CONNECTIONSIN MINI -J -BOXES WITH WIRE NUTS PROVIDED BY THE MANUFACTURER. ALL WORK PERFORMED IS TO COMPLY WITH THE UNIFORM BUILDING CODE, CALIFORNIA ELECTRICAL CODE TITLE 8, AND ALL APPLICABLE LOCAL CODES AND ORDINANCES. THE 300 -WATT TRANSFORMER). LOAD IS DETERMINED BY FWTURE LAMP LOAD AND DISTANCE TO THE TRANSFORMER, WHEN A.LBOX IS NOT USED, MOUNT THE CONNECTION SO THE WIRE NUTS ARE POINTING UP TO PREVENT ANY WATER FROM COLLECTING IN THEM. PAINTING THE WIRE WITH iL r S TRANSFORMERS SHALL BE LOCATED IN INCONSPICUOUS LOCATIONS USING PLANT KRYLON PRIMER GREY OR BLACK TO MATCH THE TREE COLOR IS RECOMMEMDED. t i MATERIAL OR SITE FEATURES TO OBSCURE A DIRECT VIEW OF THEIR LOCATIONS. AVOID LOCATIONS THAT ARE EASILY ACCESIBLE TO CHILDREN OR ARE IN A DIRECT PATH OF GUARANTEE: UPON COMPLETION AND ACCEPTANCE OF THE WORK, THE CONTRACTOR SHALL PROVIDE - INSTALLATION AS DESIGNED. IRRIGATION WATER. INSTALL TRANSFORMERS 12' ABOVE FINISH GRADE AND LEVEL. ALL A GUARANTEE FOR ALL WORKMANSHIP AND EQUIPMENT FURNISHED AND INSTALLED BY WIRES LEADING TO OR FROM THE TRANSFORMER SHALL BE IN CONDUIT SLEEVE THAT IS THE CONTRACTOR FOR A PERIOD OF ONE YEARFROM THE DATE OF ACCEPTANCE. INSTALLATION: FIRMLY AFFIXED TO MOUNTING SURFACE. ALL JUNCTION BOXES AND OTHER WARRANTY WORK SHALL BE PERFORMED AT NO COST TO THE OWNER AND SHALL BE THE CONTRACTOR IS TO VERIFY THE SITE, WALKWAYS, STAIRS, PLANTINGS, BUILDINGS, AND OTHER ELEMENTS, M NTS, WHICH AFFECT THE INSTALLATION. THE CONTRACTOR SHALL EQUIPMENT SHALL BE UL APPROVED FOR WET LOCATIONS. INSTALL TRANSFORMERS SHALL BE INSTALLED IN COMPLIANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND DONE ON A TIMELY BASIS. VERIFY THE EXISTING ELECTRICAL SERVICE, DISTRIBUTING AND PANEL LOCATIONS. tHE CONTRACTOR SHALL DETERMINE THE NECESSARY PANELS, BREAKERS, CONDUIT, WIRE, APPLICABLE CODES. ALL TRANSFORMERS SHALL BE CONNECTED TO GFI RATED DUPLEX OUTLETS IN WET LOCATION RATED ELECTRICAL OXES. TRANSFORMERS (EXCEPT 4 WIRING DEVICES INVOLVED WITH THIS INSTALLATION AS DESIGNED. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY COMPONENTS AND ACCESSORIES TO COMPLETE THE STAINLESS STEEL) CAN BE PAINTED TO MATCH THE BURRO UNDING SURFACES. TRANSFORMERSSHALL BE CLEARLY AND NEATLY MARKED WITH WATER PROOF MARKING INSTALLATION AS DESIGNED. INDICATING THE TRANSFORMER NUMBER, CIRCUIT TO WHICH THE TRANSFORMER IS LUMINATE ADDRESS MBERS d 27 LIGHTING FIXTURES.THE MINIMUM ALLOWABLE CABLE SIZE FOR DIRECT BURIAL IS AND FOCUS ALL EQUIPMENT TO THE SATISFACTION OF THE LANDSCAPE ARCHITECT AND OWNER. h` iy f 12 -GAUGE MULTI -STRANDS. INSTALL CABLE ALONG THE EDGE OF HARDSCAPE AND MOW TBD BY LIGHTING DESIGNER t' STRIPS WHENEVER POSSIBLE. MINIMUM CABLE DEPTH IS 12 -GAUGE MUL TISTRANDS. FDOL RE LOCATIONS: HK USA LIGHTING GROUP INSTALL CABLE ALONG THE EDGE OF HARDSCAPE AND MOW STRIPS WHENEVER POSSIBLE. MINIMUM CABLE DEPTH IS 8'. THE CONTRACTOR SHALL INSTALL 1' PVC VERIFY EXACT LOCATION WITH THE LANDSCAPE ARCHITECT, OR THE OWNER BEFORE STARTING THE WORK. ALL FIXTURES SHALL BE NEW, UNUSED CONDITION. EQUIPMENT DARK BRONZE CHASE LINE SLEEVES WITH SWEEP CORNERS FOR ANY CABLE RUN UNDER HARDSCAPE OR DIFFICULT TO ACCESS AREAS SUCH AS AT GRADE AND HIGH IMPACT AREAS SUCH AS SHALL BE THE TYPE SPECIFIED. SUBSTITUTIONS SHALL BE APPROVED PRIOR TO INSTALLATION OR ARE INSTALLED AT THE CONTRACTOR'S RISK LIGHTING FUTURES — -: _ II x ij y E - Al SEE BBQ DETAIL R+ FOR �`' % t 1, OUTLET REQUIREMENTS It - - - - tl \ a __. - E�3 a C,,/ (UNDER B f I AR. �I � - IN SLOT) - - I E-8 _ 4, E r: r- _----- ® FEAT E® LAWN i -: - — : , ^ F y r - - - —- DATE ?BY T u 0 � E-2 N � d 31 2 / - I ,I W EXISTING E C� 1Jva't' �A"CU12ES LIGHTING NOTES LOW VOLTAGE LANDSCAPE LIGHTING INSTALLATION NOTES 8 SPECS' - 4 LIGHTING LEGEND vJ1A'5,S060erC-0 LIjj4WNy GENERAL FIXTURE SVM. DESCRIPTION SCOPE OF WORK: THE SUPPLY AND INSTALLATION OF A 12 -VOLT LANDSCAPE LIGHTING SYSTEM WHICH INCLUDES THE FIXTURES SPECIFIED ON THE FIXTURE SCHEDULE AS FIXTURE LOCATIONS FOR FINAL ADJUSTMENT. ALL WIRE JUNCTIONS SHALL BE WATERPROOF WITH CAULK FILLED WIRE NUTS OR MANUFACTURER APPROVED WIRING TO FIXTURES SHALL BE CONCEALED FROM THE PRIMARY VIEW BY ROUTING THE WELL AS THE INSTALLATION OF LOW VOLTAGE TRANSFORMERS AND DIRECT BURIAL CABLE NECESSARY TO COMP COMPLETE THE PLAN AS SHOWN. THIS LIGHTING PLAN IS CONNECTIONS DESIGN FOR DIRECT BURIAL, ORAPPROVED EQUIVALENT. ONLY FULLY ENCAS ULATED WATERPROOF CONNECTORS RATED FOR DIRECT BURIAL WILL BE WIRES ON THE BACK OF POSTS, TREES AND OTHERELEMENTS AVAILABLEFOR THIS PURPOSE. CABLE MOUNTED TO TREES SHALL BE THE SMALLEST GAUGE WIRE POSSIBLE DIAGRAMMATIC AND IS INTENDED TO SHOW GENERAL FIXTURE LOCATION AND UTILITIES. THE CONTRACTOR ISRESPONSIBLETHE FOR NECESSARY LINEHOWVOLT) AND LOW ACCEPTED. TAPED CONNECTIONS ARE NOT ACCEPTABLE. - TO MAINTAINII.SVOLTS AT THE FIXTURE. USE NYLON C -CLIPS WITH A SINGLE STAINLESS STELL CREW WHEN ATTACHING CABLE TO TREES. DO NOT USE STAPLES WHEN (12 -VOLT) WORK 70 COMPLETE THE LIGHTING DESIGN AS SHOWN. TRANSFORMERS: TRANSFORMERS SHALL BE SPJ, VISTA, FX, OR OTHER APPROVED EQUIVALENT. MAXIMUM MOUNTING TO TREES SINCE THE STAPLE WILL CUT THE WIRE AS THE TREE GROWS. LEAVE A SLIGHT SLACK IN THE CABLE TO ALLOW FOR TREE GROWTH. MAKE STANDARDS: LOAD SHALL NOT EXCEED 80% OF THE TRANSFORMER RATING 240 -WATTS ON A CONNECTIONSIN MINI -J -BOXES WITH WIRE NUTS PROVIDED BY THE MANUFACTURER. ALL WORK PERFORMED IS TO COMPLY WITH THE UNIFORM BUILDING CODE, CALIFORNIA ELECTRICAL CODE TITLE 8, AND ALL APPLICABLE LOCAL CODES AND ORDINANCES. THE 300 -WATT TRANSFORMER). LOAD IS DETERMINED BY FWTURE LAMP LOAD AND DISTANCE TO THE TRANSFORMER, WHEN A.LBOX IS NOT USED, MOUNT THE CONNECTION SO THE WIRE NUTS ARE POINTING UP TO PREVENT ANY WATER FROM COLLECTING IN THEM. PAINTING THE WIRE WITH CONTRACTOR SHALL POSSES ALL NECESSARY LICENSES TO COMPLETE THE DESCRIBED WORK AND SHALL DETERMINE THE NECESSARY PANELS, BREAKERS, CONDUIT, WIRE, TRANSFORMERS SHALL BE LOCATED IN INCONSPICUOUS LOCATIONS USING PLANT KRYLON PRIMER GREY OR BLACK TO MATCH THE TREE COLOR IS RECOMMEMDED. WIRING DEVICES, INVOLVED WITH THIS INSTALLATION. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY COMPONENTS AND ACCESORIES TO COMPLETE THE MATERIAL OR SITE FEATURES TO OBSCURE A DIRECT VIEW OF THEIR LOCATIONS. AVOID LOCATIONS THAT ARE EASILY ACCESIBLE TO CHILDREN OR ARE IN A DIRECT PATH OF GUARANTEE: UPON COMPLETION AND ACCEPTANCE OF THE WORK, THE CONTRACTOR SHALL PROVIDE - INSTALLATION AS DESIGNED. IRRIGATION WATER. INSTALL TRANSFORMERS 12' ABOVE FINISH GRADE AND LEVEL. ALL A GUARANTEE FOR ALL WORKMANSHIP AND EQUIPMENT FURNISHED AND INSTALLED BY WIRES LEADING TO OR FROM THE TRANSFORMER SHALL BE IN CONDUIT SLEEVE THAT IS THE CONTRACTOR FOR A PERIOD OF ONE YEARFROM THE DATE OF ACCEPTANCE. INSTALLATION: FIRMLY AFFIXED TO MOUNTING SURFACE. ALL JUNCTION BOXES AND OTHER WARRANTY WORK SHALL BE PERFORMED AT NO COST TO THE OWNER AND SHALL BE THE CONTRACTOR IS TO VERIFY THE SITE, WALKWAYS, STAIRS, PLANTINGS, BUILDINGS, AND OTHER ELEMENTS, M NTS, WHICH AFFECT THE INSTALLATION. THE CONTRACTOR SHALL EQUIPMENT SHALL BE UL APPROVED FOR WET LOCATIONS. INSTALL TRANSFORMERS SHALL BE INSTALLED IN COMPLIANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND DONE ON A TIMELY BASIS. VERIFY THE EXISTING ELECTRICAL SERVICE, DISTRIBUTING AND PANEL LOCATIONS. tHE CONTRACTOR SHALL DETERMINE THE NECESSARY PANELS, BREAKERS, CONDUIT, WIRE, APPLICABLE CODES. ALL TRANSFORMERS SHALL BE CONNECTED TO GFI RATED DUPLEX OUTLETS IN WET LOCATION RATED ELECTRICAL OXES. TRANSFORMERS (EXCEPT 4 WIRING DEVICES INVOLVED WITH THIS INSTALLATION AS DESIGNED. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY COMPONENTS AND ACCESSORIES TO COMPLETE THE STAINLESS STEEL) CAN BE PAINTED TO MATCH THE BURRO UNDING SURFACES. TRANSFORMERSSHALL BE CLEARLY AND NEATLY MARKED WITH WATER PROOF MARKING INSTALLATION AS DESIGNED. INDICATING THE TRANSFORMER NUMBER, CIRCUIT TO WHICH THE TRANSFORMER IS CONNECTED AND THE FIXTURE GROUP BEING POWERED BY THE TRANSFORMER. DIRECT BURIAL CABI F: CABLING SHOWN ON THE PLANS IS FOR GROUPING ONLY. CABLE TO BE CIRCUITED AND SIZED TO PROVIDE A MINIMUM OF 10.5 VOLTS AND A MAXIMUM OF 12 -VOLTS TO ALL TESTING: THE CONTRACTOR SHALL COORDINATE A CONVENIENT TIME IN THE EVENING TO TEST LIGHTING FIXTURES.THE MINIMUM ALLOWABLE CABLE SIZE FOR DIRECT BURIAL IS AND FOCUS ALL EQUIPMENT TO THE SATISFACTION OF THE LANDSCAPE ARCHITECT AND OWNER. 12 -GAUGE MULTI -STRANDS. INSTALL CABLE ALONG THE EDGE OF HARDSCAPE AND MOW TBD BY LIGHTING DESIGNER E- 5 STRIPS WHENEVER POSSIBLE. MINIMUM CABLE DEPTH IS 12 -GAUGE MUL TISTRANDS. FDOL RE LOCATIONS: HK USA LIGHTING GROUP INSTALL CABLE ALONG THE EDGE OF HARDSCAPE AND MOW STRIPS WHENEVER POSSIBLE. MINIMUM CABLE DEPTH IS 8'. THE CONTRACTOR SHALL INSTALL 1' PVC VERIFY EXACT LOCATION WITH THE LANDSCAPE ARCHITECT, OR THE OWNER BEFORE STARTING THE WORK. ALL FIXTURES SHALL BE NEW, UNUSED CONDITION. EQUIPMENT DARK BRONZE CHASE LINE SLEEVES WITH SWEEP CORNERS FOR ANY CABLE RUN UNDER HARDSCAPE OR DIFFICULT TO ACCESS AREAS SUCH AS AT GRADE AND HIGH IMPACT AREAS SUCH AS SHALL BE THE TYPE SPECIFIED. SUBSTITUTIONS SHALL BE APPROVED PRIOR TO INSTALLATION OR ARE INSTALLED AT THE CONTRACTOR'S RISK LIGHTING FUTURES COLOR PLANTERS THAT RECEIVE SEASONAL COLOR CHANGES. LEAVE 24' LOOPS ATALL SHALL RE INSTALLED AS SPECIFIED BY THE MANUFACTURER. E-1 AREA DOWNLIGHT HK USA LIGHTING GROUP ZXL4-0. 57' REFLECTOR HKLED 15 WATT DARK BRONZE 15 .5 M MOUNT ON MHVL SPIKE W/GSA ANGLED GLARE SHIELD E- 2 AREA DOWNLIGHT HK USA LIGHTING GROUP ZXL4-0. 33' REFLECTOR HK LED 15 WATT DARK BRONZE 19 3.5 K COLOR TEMP MOUNT ON MHVL SPIKE E- 3 AREA DOWNLIGHT HK USA W/ GSA ANGLED GLARE SHIELD 3.5 -K C LOR T P LIGHTING GROUP ZXLF HK LED 8 WATT DARK BRONZE 16E- MOUNT ON MHVL SPIKE 4 Q SUBMERSIBLE W/ GSA ANGLED GLARE SHIELD LED LIGHT 8 TBD BY LIGHTING DESIGNER E- 5 Q BOLLARD LIGHT HK USA LIGHTING GROUP CMBL-150. - 3W LED 120 V DARK BRONZE 20 LINE VOLTAGE W/ GFI OUTLET MOUNT IN 12' CONC. FOOTING (2.7K COLOR TEMP) E- 6 AREA DOWNLIGHT HK USA LIGHTING GROUP ZXL4-0. 57' REFLECTOR HK LED DARK 15 WATT BRONZE 3 3.5 K COLOR TEMP, C1355 DIRECT SWITCH TO ADJ. WALL WALL MOUNT 120 V W/ GSA ANGLED GLARE SHIELD LED LISTED TAPE LIGHT LIG SI ENV RONMENTAL 6468-43 WARM WHITE MOUNT UNDERSIDE OF LIGHT WP-CT3528-120-10-REEL 12 LF BAR TOP -E--81 ' %` BBQ LIGHT TEKA ILLUMINATION HLP LED B 12 VOLT 3WATT BRONZE 4 DECK MOUNT ON BBQ COUNTER E- 9 POOLISPA LIGHT PENTAIR GIOBRITE LED 12 VOLT COLOR (602053) LED 12 E-_1 01 T# TRANSFORMER SPJ LIGHTING Tt: MTP600-SS 2 PHOTO CELL & TIMER E- 11 UPLIGHT GRADE AURORA LIGHT LWL1 TERRA COTTA 2 WATT DARK 6 3.5 K COLOR TEMP LED BRONZE WIDE FLOOD E-12 �� LED WET LISTED TAPE LIGHT MAXIM LIGHTING RAINBOW AQUA 24' WARM WHITE 120 LF MOUNT INSIDE EDGE OF WATER FEATURE LOW VOLT WIRE 12 GUAGE DIRECT BURIAL }C WALL MOUNTED SWITCH AsW 1> SAan1 ` rAnum I lewhoMep-m- C 15AV4lNEEy¢t"�. I SV%� fl — ALE: 1/8 9 0 IF 8' 4' 0' 4' 8' 16' GRAPHIC SCALE LOT 5A 52340 ROSS AVENUE THE MADISON CLUB LA QUINTA, CALIFORNIA LIGHTING PLAN Landscape Construction Documents: 100% ORIGIN DATE 03-30-16 PLOT DATE 11.02.16 DRAWN BY: TP CHECKED BY: DG - �=111w 13 of 13 L®4.0 =2 fjr�