Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
07-2524 (SFD)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: C�0-7-=00002524 Property Address: 4-53.5'56—ROSS—AVE APN: 767-200-998-46 -330761- Application description: DWELLING - SINGLE FAMILY Property Zoning: ' LOW DENSITY RESIDENTIAL Application valuation: • 812655 Applicant: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: ROBERT SPALETTO . 53-556 ROSS AVENUE DETACHED LA QUINTA; CA 92253 Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Cl ss: BLicense No.: 410408 ��r. acto X 'fj, %0exempt DER DECLARATION I hereby affirm under penalty of perjury that I am the Contractor's State License law for the following reason (Sec. 7031.5, Business and Pe: Any city or county that requires a permit to construct, alter, improve, demolish, or repair anior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 155001.: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ' 1 _ I I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the. work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address - LQPERAIIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/06/07 Contractor: 'd ' JEHA CONSTRUCTION, MICHAEL 3089 SANDSTONE ROAD ALAMO, CA 94507 Q� (925)250-4038 Lic. No.: 410408 ---------------------------------- ---- WORKER'S COMPENSATION DECLARATION I hereby.affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 238-0002300-06 I certify that, in the performance of the work for which this permit is issued, I shall not employ any . person in any mann o as be 'ect to the workers' compensation laws of California, and agree that, if should bec me bject t the workers' compensation provisions of Section 3700 of the Labr Code, I sha thwith co ly with those provisions. ate: A 'rte WARN( G: 'AIL RE TO SECURE WORKERS' COM ANSA ON COVERAGE IS UNLAWFUL, AND SHALL SUBJECT A EMPLOYER TO CRIMINAL PENALTIES IVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each,person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and a �ui ove information is correct. I agree to comply with all city and county ordinances and slat relatingco tion, and hereby authorize representatives of this cry torenter upon [he ov -mentioned r ' specti purooses. (Applicant or Agent): Application Number . . 07-00002524 ------ Structure Information 9,509SF DWELLING/V-NR/RES-3/CLASS A -FR ----- Other struct info . . . . . CODE EDITION 2001/2005 $# BEDROOMS 4.00 FIRE SPRINKLERS .NO GARAGE SQ FTG 1680.00 PATIO SQ FTG 766.00 NUMBER OF UNITS 1.00 ------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 9509.00 Permit . . . . . . BUILDING PERMIT Additional desc . Permit -Fee . . . . 2978.50 Plan Check Fee 1936.03 Issue Date . . . . Valuation . . . . 812655 Expiration Date 5/04/08 Qty Unit.Charge Per Extension BASE FEE 2039.50 313.00 3.0000 ---------------------------------------------------------------------------- THOU BLDG 500,001-1,000,000 939.00 Permit MECHANICAL Additional desc . Permit Fee . . . . 274.50 Plan Check Fee 68.63 Issue Date Valuation . . . . 0 Expiration Date 5/04/08 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36.00 5.00 11.0000 EA MECH FURNACE >100K 55.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 4.00 9.0000 EA MECH B/C,<=3HP/100K BTU 36.00 5.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU "82.50 .6.00 6.5000 EA MECH VENT FAN 39.00 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 396.42 Plan Check Fee 99.11 Issue Date . . . . Valuation" 0 Expiration Date-. 5/04/08 Qty Unit Charge Per Extension BASE FEE 15:00 - 9509.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 332.82 LQPEn11T LQPERAtIT Application Number . . . . . 07-00002524 Permit . . . . . . ELEC-NEW RESIDENTIAL Qty Unit Charge Per Extension 1680.00• .0200 ELEC GARAGE OR NON-RESIDENTIAL 33.60 1.00. 15.0000 EA . ELEC TEMPORARY POWER POLE ---------------------------------------------------------------------------- 15.00 Permit . . . PLUMBING Additional desc . Pprml r FPP -A4 C; %1i Plan, check Fag 905 , 114. Issue Date . . . . Valuation . . . . 0 Expiration Date 5/04/08 Qty Unit Charge Per Extension -BASE FEE 15.00 32.00 6.0000 EA PLB FIXTURE 192.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 10.00 6.0000 EA PLB ROOF DRAIN 60.00 3.00 7.5000 EA PLB WATER HEATER/VENT 22.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 19.00 .7500 EA PLB GAS PIPE >=5 14.25 1.00 15.0000 EA PLB GAS METER ---------------------------------------------------------------------------- 15.00 Permit . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation 0 Expiration Date 5/04/08 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments .9,509SF DWELLING/V-NR/RES-3/CLASS A -FR THIS PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL AND SPA OR DRIVEWAY APPROACH. 2001 CBC, CPC, CMC, 2004 CEC 2005 ENERGY. November 6, 2007 8:25:09 AM AORTEGA --------------------- ------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 1531.63 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 193.60 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE 22.50 LQPERAtIT Application Number . . . . 07-00002524 ----------------------- Other Fees . . . ------------ . . . . . -------------------- DIF LIBRARIES - RES ------ --------------- 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES B1.26. DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid Credited Due --------------- Permit Fee Total ------- 4010.17 .00 .00 4010.17 Plan Check Total 2190.21 1000.00 .00 1190.21 Other Fee Total 6303.99 .00 .00 6303.99 Grand Total 12504.37 1000.00 .00 11504.37 LQPERA11T t. . 1 c P.O. BOX 1504 Bi3ilding , ` 1?�C>S 78-495 CALLE TAMPICO Address ,U P�p'���%R��� �V�• LA QUINTA, CALIFORNIA 92253 Owner L/ b 1`—d a, T BUILDING: TYPE CONST. 06C. GRP. 1�_� A.P. Number —7 APPLICATION ONLY Mailing Address Address ZS 6y6i 73G'1 (Legal Description ZS - & Classif. I Lic. # miull., r-nyr., Designer �a NIA01 rJ %MZ4�7 Address Tel. G 45 OL�ND �—T�. `ZGo 3Ze> = G FCity Zipq/f�� State p AM Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason WORKER'S COMPENSATION DECLARATION hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip Project 10 6 l_F. FA rl I Ft. S�--1 No Ri7 Sipa i Rtr 2 No. Dw. Units Newt' Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. a00 0A Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure CITY TOTAL -t1.A_fA1VC_FWUtJV REMARKS ZONE: BY: Minimum Setback Distances: Front Setback frorn Center Line Rear Setback from Rear Prop. Line Side Street Setbacx from Center Line Side Setback from IProperty Line FINAL DATE Issued by: Validated by: Validation: INSPECTOR Date Permit WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINAOCE Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: A %4OUNT LEVELONEAMOUNT: LEVEL TWO AMOUNT: NUTIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: C;-1ECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Residence is af. e.,N4 dison Club Date: November 5, 2007 Owner's Name: Robert Spaletto Phone No. Project Address: 53-556 Ross Avenue La Quinta, CA Project Description: Single family dwelling APN: 767-680-051 Tract #: Type of Development: Residential I i Commercial Total Square Feet of Building Area: 9,509 Sq. Ft. Lot #'s: Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized,te-sigu\on beha�f the owner/developer. Dated: November 5, 2007 Signature: ******************************************/*******1k******4************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJE T HAVE BEIEN OR ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing 17620 65995 Approval Prior to 1/1/87 Number of Sq.Ft. 9,509 Amount per Sq.Ft. 3.48 Amount Collected 33,019.32 Building Permit Application Completed: Yes/No BE SATISFIED IN Not Subject to Fee Requirement By: Carey M. Carlson, Asst. Supt., Support Services Certificate issued by: Elvira Mattson, Secretary III Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment cf the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as kcrein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as det:rmined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been i;sued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. MV:c/mydocs/devfees/certificate ofcomp] iance form updated 3-2007 3/9/07 Nov -06'-07 09:07A bb 3143291 P.01 FIDELITY NATIONAL TITLE COMPANY SUBDIVk%ON DEPARTMENT WHEN RECORDED MAII. TO, R. 1). Spaletto Enterprises, Inc. 100 Railruad Ave Danville, CA 94526 MAILTAX TAX STATF.MFNT TO: SAME. AS ABOVE DOC # 2005-0951994 11/16/2005 w oop Fee:16.00 Page 1 of 4 Doc T Tax Paid Recorded in Official Records County of Riverside Larry W. Ward Assessor, County Clerk & Recorder I IIIIII IIIIIII III IIIIII 11111111111111111111111111111111 M S U MAC*- SI2C DA Pf;f)H NOCOR SMF 1 MItiC: R L Cor'Y RCrUND NCHG PXA A _ LU.G I)OCUMENT TRANSFF.It WAX $ 1,925.00 XX Computed on the consideration or value of property conveyed; OR O Computed on the consideration or value less liens or encumbrances remaining at the time of ~ale. inn 0 Signature of Declarant or Agent determining tax •• F irnl Natne GRANT DEED FOR A VALUART.F. C ONSIDLRATION, receipt al' which is hereby acknowledged, FAST OF MADISON. LLC, a Delaware limited liability company ("Grantor"), hereby GRANT($) to R.D. Spaletto Enterprises, Inc., a.California Corporation ("Grantee"), the real property located in the City of La Quinta, County of Riverside, State ol'C'alilomia, described as: See Legal Description attached hereto and incorporated herein as IINhibit "A" til_ BJECT TO all matters o('record including, without limitation, the covenants and agreements described in Fxhibit "A" attached hereto. Dated: 9/19/05 FAST OF MADISON. LLC, a Delaware limited liability company liy: 120 Acre Partners, LLC, a Delaware limited liability company Its: Managing Member By: Discovery La Quinta Investors, LLC, a Delaware limited liability company its Authorize cprc nt nvc By. Jo. eph T.. Arenson Its: Authorized Representative Nov -06-07 09:07A bb 3143291 P_02 STATF.OF � ) ss. COUNTY Ur7)V'5&- t ) On _149 ,2005, before me, the undersigned, a nctary public in and for said State, personally app , reel Joseph L. Arenson, Authorized Representative of Discovery La Quinta Tnvestors, I.I.C:., (whose identity was proved to me on the basis ol'satis('actory evidence) to be the person whose name is subscribed to the within instrument and acknowledged to me that he executed the same in his authorized capacity, and that by his signature on the instrument the person, or the entity upon behall'of'which the person acted, executed the instrument. WITNESS MY HAND ANIS OFFICIAL SEAL. .. ,�CONNIE CONCETTO Nilo COMM. #1417229 �/ 2Z� rSF.A1,� y r� xMy.%tuc - caatr.or. mv_-r=E c.XMIT Signature — , E mor 11. M7 Nov -06-07 09:07A bb EXHIBIT "A" Legal Description Parcel No. 1: 3143291 P.03 Lot -..-.46 (the -`I.ot"') of Tract No. 33076-1 as shown on Subdivision Map tithe "Map") recorded on September 7, 2005, in Book 388, Pages 57 to 79, inclusive, of Maps, in the Of] .cc of the Riverside County Recorder. EXCFPTTNG AND RESERVING THF.RF.FROM TO GRANTOR, and its successors, assigns, invitees, licensees and employees, together with the right to grant and transfer Ell or a portion of'the same, all easements and rights for access, ingress, egress, encroachment, maintenance, drainage, support, and for other purposes over the Association Maintenance Areas and of. -ler portion of the Lot, reserved to Grantor in the following instruments: 1. The Declaration of Covenants. Conditions and Restrictions and Reservation of'F.asements lbr The Madison Club Owners Association (the "Declaration"), recorded on September 13, 2005, as Instrument No. 2005-754387, of Official Records of Riverside County, California (the "Official Records"); FURT11F.R REST{RVIW T[IL.REFROM, the right to enter the Lot for a term of twelve (12) months following the recordation of, this CTrant reed, to complete and repair any improvements or landscaping located thereon as determined necessary by Grantor, in its sole discretion, in order to comply with requirements for the recordation of the Final 'Tract Map, the grading ol'said Tract and/or in compliance with the requirements of applicable governmental agencies. Such entry by Grantor shall be preceded by reasonable notice to Grantee before such entry. if this reservation of right of entry is not complied with by Orantee. Urantor may enforce this right of entry in a court oflaw. Grantee shall be responsible liar all damages arising out of said breach including attorneys' fees and court costs. This reservation ol'righl ol'cntry shall automatically expire twelve (12) months from the recordation of this Grant Teed, Parcel No. 2: Nonexclusive casements for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as described in the Declaration. Nov -06-07 09:08A bb 3143291 P.04 S1.113J1G'1' '1'U: 1. Non delinquent general, special and supplemental real property taxes and assessments. 2. All other covenants, conditions, restrictions, reservations, casements, rights and rights-of- way of record including, without imitation, the Declaration and the Map for 'Tract No. 33076-1. Grantee, by acceptance and recordation of this Grant Deed, hereby (a) E,ccepts and approves all of the foregoing in this (Irani Deed, (b) grants to Grantor and The Madison Club Owncrs Association such powers and rights as are set iorth in the Declaration, and (c) accepts, covmunts and agrees to be bound by and assume performance of all of the applicable provisions and requirements set forth in the Declaration, including Section 13.15 establishing the procedure for resolving disputes with Grantor, and the notice, which provisions and requirements are acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to he performed by Grantee under the Declaration. The restrictions on use and occupancy of the Lot are set forth in the i')eclaration to which this Grant Deed is specifically and expressly made subject. GRAN'1'I-.I; I lERL,'BY ACCEPTS AND APPROVES T1TP. FOREGOING. granting unto Grantor and The Madison Club Owners ASso iation such powers and rights which are set forth in the Declaration defippd above, on /jij. � , 2005. R.D. S terprises,•Inc., a C o _C Dra0 on Roberx/D. Spal etto, President STATE OF ss. COUNTY 01,e"� On 1�� a �;I, 2005, before me, the undersigned, a notary public in and (irr said State, personally appeared , —'ZO, j ., personally known to me (or proved to me on the basis of satisfactory evidence) to bd the persons whose names arc subscribed to the within instrument and acknowledged tome that they executed the same in their authorized capacities, and that by their signature on the; instrument the personsti or the entity upon behalf of which the persons acted, executed the instrument. WI'I'Nl?SS MY I lANr) AND OFFTC:TAT. SF.AI.. 2C�4 .... — `.:. - FSFALj Signature 4CONNiE CONCEM COMM. #1417229 w)TARY PueuC - CAUFORNIA om v► RNETIME COUNTY Commhslon Ophn Mov 11.2oG cMNle T' W", *14112,2,, 1Ouurrareuc-rMFMIF Aomrris*m e0se Uw 11.4007 Apr 11„08 12:13p Antonio 7607766582 p.1 R F STRUCTURAL CONSULTANTS. INC. 41-865 BOARDWALK, STE. 208, PALM DESERT, CA 92211 PHONE (760) 836-1000 FAX (760) 836-0856 APRIL 11; 2008 MICHEAL JEHA CONSTRUCTION 3089 SANDSTONE ROAD ALAMO, CA. 94507 ATTN.: Mr. MICHEAL JEHA Re.: MADISON, LOT # 46-A 53-556 ROSS AVE. LA QUINTA, CA. 92253 JOB NO.: 4724 DEAR IvIICHEAL THIS LETTER ADVISED THAT WE HAVE OBSERVED THE STRUCTURAL REQUIREMENTS THAT ARE VISIBLE DURING CONSTRUCTION AT THE TIME OF OUR SITE VISIT. WE BELIEVED THAT THE AS -BUILT CONSTRUCTION AT THE TIME OF OUR VISIT IS IN GENERAL CONFORMANCE WITH OUR STRUCTURAL PLANS AND RELEVANT CORRESPONDENCE ISSUED BY OUR OFFICE. WE OBSERVED THE BUILDING IN ITS FRAMED CONDITION PRIOR TO INSTALLATION OF DRYWALL AND STUCCO. WE OBSERVED THE VISUAL AND ACCESSIBLE STRUCTURAL REQUIREMENTS. (EXCLUSIONS ARE ITEMS SUCH AS FOOTING SIZES AND REINFORCEMENT, TOP PLATE SPLICES, ROOF SHEATHING, AND HARDWARE ABOBE THE TOP PLATE OR THE ROOF SHEATHING). RESPECTFULLY SUBMITTED �✓'�QROFESs�Qir M. � ti pay y� 4 NO. 57958 rn Exp. 06-3ao 8' Cfvi I- Zeyad Faqih P.E. OF C.A. NOV-24-2008 07:35 AM "CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTI Project Address 53� 6fd 3 3 Builder or I taller Contact Tolephcite — 2221 AL MRS Rater ��-- /Telephor A7,&)).7/c►-r177 �1 Date Firm zr Street Address: or or P. 02 CF -4R HERS RATER CPLIANCE STATEMENT The house was: J Jig Tested ✓ E3 Approved as part of sample testing, but was not tested As the HEM rater providing diagnostic testing and field venfcstiok I oergfjr that the house identified on this form complies with the diagnostic tested compliance requuementa as checked ✓ on this form. The HERS rater must check and ver that the new distribution system i8 fully ducted and comd tape is used before a CP -4R may, be released on every tegted build' The HERS rater must not release the CF -4R until a properly completed and signed CF -6X has been received for tE0-5aample and tested The installer has provided a copy of CF -6R (Installation Certificate). New duds are fully ducted (i,e,, does not was building cavities as plenums or platform returns in lieu of ducts). New ducts with cloth backed, rubber adhesive duet tape is installed, mastic and draw bands are used in cornbination with clot backed, tubba adhesive duct Up to meal looks at duct connections.). v firMINIMUM REQUIREM)Er.NTB FOR DUCT L1I:AKAGE R,EDVCnoN CONVIUANCE CREDIT Procedures for field verification and diagnosticof air distribution systems are available in RAWAppendix RC4.3. Duct Diagnostic Leakage Testing RaWtA Wpxe. vAiLi � NEW CONSTRUCTION: ' Duct Pressurintion Test Results (CFM (@25 Pa) Measured Values 1 Enter Tested Leakage Flow in CFM; I n -2 2 . _• . •.......�.�r.a�� �,.ar Im" - L4 ';00108 v u rieatrng� or + JF1Vleasured Enter Total Fen Plow in CIrM; 3 Pass if Leakage percentage < 6% j 100 x/ Z ne # 1 (� ) (Line # 2)j ALTERATIONS:. Duct System and/orrAC 1Iui went Chitn t 4 Enter Tested Leakage Flow in CFM from CF.Qt pre -Test of Existing Au System F Dud System Alteration and/or Equipment Change -Out 5 Enter Tested Leakage Flow in CFM: Final Tent of New Duct S at or Allred Duct fm bunt System Alteration and/or Eauiument Ch t. Enter Reduction in Leakage for Altered Duct System j� , , ire #) us I 6 (Only if Applicable) 7 Entr Tested Leakage Blow in CFM to Outside (Only if App)' blo) 8 Entire New Duct System - Pass if Leakage Percentage < 6% 100 x(Line it S / Line # 2)11 PEST OR VERIFICATION — . — -- -- STANDARDS: For Alt rr..-- ered Duet System and/or IEiVAC 19 ..o.�_.�_..- - 9 I §and f Leakage Percentage < 15% [ 100 x (�—(bine # 5) / Line # 2j]] 10 f Leakage to Outside Percentage r 101/0 [100 x L.__(Line # / ine # 11 f Leakage Reduction Percentages 6044 [1 oo x [,„_(Line # erification by Smoke Test and Visual rn�r.~t,.... Psas If One of Lines # 9 through # 12 to R a�In7lq Ron ✓ V, 0 Paas O Fail O Pass O Fail aP q Q Foss 17 Fail 0 Pass 0 Fail ..-.irunrrnarcfM►�lgQpCE�/'Ul1NR��" L,IC/— / )b jP6 D�e 03-gg.X�a_ y y�D �7 nrberdlJOS 1P5 6 a 4.1" --3. f to r NOV-24-2008 07:35 AM P. 03 CERTIFICATE OF FIELD VERIFICATION $ DIAGNOSTIC TESTING CF4R Project Address . Bui1dwN� s Builder Contact Tele0wim Plan Number KMS Rater//� V / 11 ge a 76'2 Telephone 'r -7. Sample Grow Number ✓ Compliance Method a 17 No Climate Zone S' Certifying Siouture / D Date Sample House Nmb,_— Firm installation of thefre equipment shall be verified. HERS providar Street Address: J / City is Zip: &),nr4, Uopm go: BU1LDLR, liLKS PKUVWLR AND HULL UNG DWARTM ENT ITERS RATER OMPLIANCE STATEMENT The house was: ✓ Tested ✓ ( Approved as put of sample testing, but was not tented As the H1BitS rater providing dis►gnoatie t�dng and Geld v�r�o�on, I certify that the house identified on this form complies with rho� osk tested compliance requirements as checked an tht'a form. ✓ X ne installer has provided a copy of CF -GR (Installation Certificate), ✓XTHERMOSTATIC EXPANSION VALVE (am►)� ��, hwedurm fv ield uer(f Icatiax of *rm w&hc eaipmts t re aWat IgM in )UCU ✓ 0 REmG=ANT CHARGE A E 49URII1WW Verification for Required Refri cram Char a for Split System Sincooling SvItimm WiWout Tiontmontasic Expansion Valves Outdoor Unit Serial # Location Outdoor Unit Make Outdoor Unit Modd Cooling Capacity hv'hr Date of Verification Date of Refrigerant Gauge Calibration (must be checked monthly) Date of Thermocouple Calibration (owd be checked mourt<tly) Note: The system should be installed and charged in arxordance shall be documented on CF -611 before starting this procedure. If Charge Measure Procedure rocedures for Determining Refrigere 0 Yea O No A copy of air ns and installer verification rater shag use the Altettutive charh e Residrr►dal Compliance Forma 40612005 ✓ ✓ Access is provided fat' inspection. The procedure shall consist of ✓ os 17 No visual verification that the TXV is installed an dw system and [� installation of thefre equipment shall be verified. Yea is a gum Pass Fail ✓ 0 REmG=ANT CHARGE A E 49URII1WW Verification for Required Refri cram Char a for Split System Sincooling SvItimm WiWout Tiontmontasic Expansion Valves Outdoor Unit Serial # Location Outdoor Unit Make Outdoor Unit Modd Cooling Capacity hv'hr Date of Verification Date of Refrigerant Gauge Calibration (must be checked monthly) Date of Thermocouple Calibration (owd be checked mourt<tly) Note: The system should be installed and charged in arxordance shall be documented on CF -611 before starting this procedure. If Charge Measure Procedure rocedures for Determining Refrigere 0 Yea O No A copy of air ns and installer verification rater shag use the Altettutive charh e Residrr►dal Compliance Forma 40612005 FROM SLADDEN PALM DESERT (THUN AN 10 2008 8:22/ST. 8:22 No.6802770786 P 1. Sladden Engineering 77-725 Enta4d Lane, Suite 100, Palm Desert, CA 92211 (760) 7TI-3893 Fax (760) 772-3895 6782 Stanton Ave., Suite A, Sucna Park, CA 90621 (714) 523.0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223.(951) 845-7743 Fax (951) 845.8863 January 7, 2(W Mr. Mike Jeha 3089 Sandstone Road Alamo, California 94507 Project: Subterranean Theater Room 46 Ross Avenue 554 Madison Club La Quinta, California Subject: Compaction Report — Subterranean Theater Room Backfill Project No. 522-07302 08-01-005 Summarized in this report are the results of in-place density tests performed at the s)bject site during the backfilling of the subterranean theater room of the subject residence. The project site Is located 46 Rods Avenue within the Madison Club Development in the City of Im Quinta, California. Field testing was performed from November 30, 2007 through December 3, W. Testing indicates that a minimum of 90 percent relative compaction was attained in the areas tested. The passing test results indicate compliance with the project specifications at the tested locations and depths but are no guarantee or warranty of the contractors work. field Tests: In-place moisture/density tests were performed using a nuclear density gauge in accordance with test methods ASTM D 2922 and ASTM D 3017. A total of 8 density rests were performed. The test results are summarized on the attached data sheet. Laboratory Teats: The molsture-density relationships for the tested materials were determined in the laboratory in accordance with test rt,i.-shod ASTM D 1557-91. If there are any questions regarding this report or the testing summarized herein, please contact the undersigned. Respectfully Brett L-�M"n Principal Engineer E,tp• 9-ao•2oo8 ,P Com action/ 1 Copies 4 /Mr. Mike Jeha FROM SLADDEN PALM DESERT PROJECT NAME, -46- Ross Avenue LOCATION: U Quinta, California (THU)JAN 10 2008 8:23/$T. 8:22"No.6802770786 P 2 TEST RESULTS PROJECT M. 522-07302 REPORT NO: 08-01-005 Toss no Date Testald LOW" j I .W"son In pbw In pLaw ^ a'tlky 1 2 3 4 5 6 7 21/30/2007 11/30/2007 12/3/20071, 12/3/2007 12/3/2007 12/3/2007' DaCKTIII Basement (E) Basement (N) Basement (W) Basement (S) Basement (S) Basement (E) Basement (N) Basement (W) PG - Pad Grade BPG = Below Pad Grade 4' BPG 4' BPG 6' BPG 3' BPG PG PG PG PG 104.0 103.2 102.6 105.3 104.7 99.1 101.5 100.6 16.0 16.4 13.5 14.7 16.4 13.0 15.5 15.1 95 94 93 96 95 90 92 92 110.0 110.0 110.0 110.0 110.0 110.0 110.0 110.0 January 7, 2008 sbddenEngkm t 1 NOV-24-2008 07:36 AM P.04 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING CF4R Project Address Builder Ne e I yt� Builder Canted Telephone Plan Number 1V 1 iJ, 2 HERS RaterTelephone sl�Coir .,,;/ l�7�r^/�- 3 Sam le Grow Number 0 No Certifyi ignature Date Sample House Number FirmERS T HProvider CLQ -3 V, 6, 4: c Duct soakage reduction credit verified Street Address; City tatelzip: Cooier to; HUH.DER. HER$ PROVIDER AND BUMMING DEPARTM>taNT HERS RATER C PLIANCE STATEMENT The house was, ✓ cited ✓ ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the house identified on this form complies with the dOostic tested compliance requirements as checked on this form. ✓ 0 The installer has provided a copy of CF -6R (lnstallatim Certificate). _ ✓ ❑ ADEQUATE AIRFLOW VlI+ MCATION O Yes 1 0 No I Duct design exiats on plans .3 are afwilable In PA (W. Appen&y Rls,.1. ad I I r M F a �t cwt of I CFM tl ToursI I cfm/ton ✓ I C7 Yes r C3 No Measured airflow is greater than the criteria in Table AE -2 © ❑ ✓ CI MAXIMUM COOLING CAPACITY Praeedurar &r doierminino marimum eaalino lied eaaecity aria amilable in RAM Ammn&r M. i 1 ✓ 1 O Yes ❑ No Adequate airflow verified (see adequate airflow credit) 2 ✓ C) Yes 0 No Refrigerant charge or TXV 3 ✓ O Yea D No Duct soakage reduction credit verified 4 ✓ O Yea O No Cooling capacities of inatalled systemse s maxim cooli1c�aw indicated on the Performance's MIR d RF 5 ✓ d Yes C7 No If the cooling capacities of installed Otems arehdda maxim cooling capacity in the CF -IR, then the electrjW input for the installed systems must be 5 to electrical igo. in the CNIR and RF 4, ✓ ✓ ❑ ❑ Yes to 1 2 and 3, and Yes to either 4 or S is a pass Paas Fail ✓RIGH EER AIR CONDITIONER 1'roceduree for verifivation are available in RAC 1 41 1 21yes 1 Cl No '):.Fr.R values of i 2 ✓ Yes 1 CI No For split system 3 ✓ Yea 1 ❑ No I Time Delav Rel '44 Uhifi W// wendix N. ad systems match the CF -1 Verified J Residential Comph(mve Fon"s _ Uerember 2003 Mar 27 08 04:42p Antonio . 7607766582 p.1 d R F STRUCTURAL CONSULTANTS, INC 75-153 MERLE DRIVE, STE. B, PALM DESERT, CA 92211 PHONE (760) 836-1000 FAX (760) 836-0856 I, MAIL RAYMOND RFSTRUCTURAL.COM I MARCH 27, 2008 MICHEAL JEHA CONSTRUCTION 3089 SANDSTONE ROAD ° ALAMO, CA. 94507 ' Attn.: Mr. MICHEAL JEHA Re.: MADISON, LOT # 46-A 53-556 ROSS AVE. LA QUINTA, CA. 92253 FOLLOW-UP TO STRUCTURAL OBSERVATION JOB NO.: 4724, CASITA AND VALLET SHACK ONLY DEAR MICHEAL THIS LETTER ADVISES THAT WE HAVE OBSERVED THE STRUCTURAL REQUIREMENTS THAT ARE VISIBLE DURING CONSTRUCTION AT THE TIME OF OUR SITE VISIT. WE BELIEVE THAT THE AS -BUILT CONSTRUCTION AT THE TIME OF OUR VISIT IS IN GENERAL CONFORMANCE WITH OUR STRUCTURAL PLANS AND RELEVANT CORRESPONDENCE ISSUED BY OUR OFFICE. WE OBSERVED THE STRUCTURAL DETAILS PRIOR TO INSTALLATION OF DRYWALL AND STUCCO. WE OBSERVED THE VISUAL AND ACCESSIBLE STRUCTURAL REQUIREMENTS. RESPECTFULLY SUBMITTED ZEYAD FAQIR, PE �OQROFESSib, yip M. r c No. 57958 i * Exp. 0630-0 C l i - ` ��- F OF CAO1 WEDDLE SURVEYING MAPPING, INC. Boundary •Construction •Topographic •Aerial Sui —ya n.,.n ✓u. vcyu v• u a v..........6 January 4,,2008 -Mr. Timothy R. Jonasson Public Works Director / City Engineer City of La Quinta 78-495 Calle Tampico La Quinta; CA 92253-1504 Re: Pad/Form-Grade Verification City of La Quinta JEHA RESIDENCE Lot 46A Lot 46 Tract No. 33076-1 Ross Avenue HIDEWAY APN 767-680-051 ' Dear Mr. Jonasson: We have performed a field survey to determine the vertical`location of the Building Pad and Building Form for the above referenced project. The elevations observed are as follows: PAD (DESIGN) - PAD (AS-BUILT) 998.7 998.7 FORM (DESIGN) FORM (AS-BUILT) 999.20 999.20 These field observations are in substantial conformance with the Precise Grading Plan prepared by ESSI SHAHANDEH, CIVIL ENGINEER, dated 10/17/07, approved by the City of La Quinta Building & Safety Department and the building horizontal location substantially conforms to the required setbacks and site layout as shown on the approved site plan. Sincerely, WEDDLE SURVEYING MAPPING, INC. David L. Weddle, President L.S. 5570, exp 09/30/09 P.O. Box 10418 • Palm Desert, CA 92255-0418 73-960 Hwy. -114, Ste. 6 • Palm Desert, CA 92260 • 760.346.3748 E-Mail:-WedSury@aol.com • Fax 760.346.3 749 Bin # City of La Quinta Building u Safety Division 45 0.$ D t' P.O. Box 1504, 78-495 Calle Tampico cjQs ��6,,,pp pa La Quinta, CA 92253 - (760) 777-7012 izcwicv-kr .., Building Permit Application and Tracking Sheet Permit # O�-2SZ Project Address: 5 3 .oI5s p,k,jrl—" Owner's Name: s�'TTb A. P. Number: Address: Legal Des 1 n: City, ST, Zip: Contract M a Telephone: Address: C: `7� Project Description: .� City, ST, Zip. L s S b' S i R -u Telephone: J State Lic. # : City Lic. #: Arch., Engr., Designer: —I uS 400 Gtpt�,T i!< t.,& Address: Ci -S O k,.jr 4 r-r--�enr't— -t:, p � Z-6 Ci� ftltA City, ST, Zip: p Lt"`S PN\ �65 � C17-2-&q'f T r&JNP pGprl's Or -i 13 . Telephone:l G o -3 33. 91,1 —n Construction Type: Occupancy': Project type (circle one): New Add'a Alter Repair Demo State Lic. #: D Name of Contact Person �.! I. ��� Sq. Ft.: #Stories: #Units: Telephone # of Contact Person: 0>3 Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rcc'd TRACKING. PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cates. Called Contact Person Plan Check Balance Energy Calcs. Plans picked up 1 v Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"d Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''" Review, ready for corrections/issue Developer Irapact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees T Certificate of-Occupancy 4:4 OF Building & Safety Departmen t This Certificate is issued pursuant to the requirements of Section 109 of the California Building r Code, certifying that, at the time of issuance, this structure was in compliance with the,. s provisions of the Building Code and the various ordinances. of the City regulating building construction and/or use. - BUILDING ADDRESS: 53-556 ROSS AVE Use classification: SINGLE FAMILY DWELLING- Building Permit No.: 07-2524 Occupancy Group: R-3 Type of Construction: VN Land Use Zone: RL l Owner of Building: ROBERT SPALETTO Address: 53-556 ROSS AVE City; ST, ZIP: LA QUINTA, CA 92253 a By: STEVE TRAXEL Date: DECEMBER 30, 2008 Building Official '. - { ! POST IN A CONSPICUOUS PLACE .-: TITLE 24 REPORT f Title 24 Report for: Villa At Madison Main Residence" Lot 46A, The Madison Club La Quinta, CA 92253 Project Designer: Benjamin Hertz, Architect 645 Oleander Road - Palm Springs, CA 92264 760-320-1644 Report Prepared By: Dave Bricker Energy Driven Solutions Inc P. O. Box 6705 La Quinta, CA 92248 .(760) 774-3676 Job Number: CITY OF lA QUINTA 08092007A BUILDING & SAFETY DEPT.) APPROVED FOR CONSTRUCTION Date: k4!�L gY 8/14/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: 08092007A , User Number: 6168 TABLE OF CONTENTS 19 , Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 15 Form WS -5R Residential Kitchen Lighting 17 HVAC System Heating and Cooling Loads Summary 18 I , \ r J r EnergyPro 4.3 by EnergySoft Job Number: 08092007A User Number: 6168 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R Villa At Madison Main Residence 8/14/2007 Project Title , Date I nt 46A The Madison Club I a Quinta Project Address Building Permit # Fnerav Driven Solutions Inc (760) 774-3676 Docurneffifation Author Telephone Plan Check/Date FneravPrn Compli ce Method CA Climate 7nne 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.71 3.40 0.31 Space Cooling 57.52 49.77 7.75 Fans 8.24 9.15 -0.91 Domestic Hot Water 2.76 4.25 -1.49 Pumps 0.00 0.18 -0.18 Totals 72.23 66.76 Building Type: W Single Family ❑ Addition ❑ Multi Family ❑ Existing + Add/Alt Building Front Orientation: (W) 270 deg Fuel Type: Natural Gas Fenestration: Area: 1,770 ft2 Avg. U: 0.41 Ratio: 20.2% Avg. SHGC: 0.46 BUILDING ZONE INFORMATION Zone Name Floor Area Volume Zone 4 HVAC System 1 _43�07 a Zone 6 HVAC System 761 R 9 Zone 7 HVAC System 1 717 18.3 Zone 8 HVAC System 763 72 OPAQUE SURFACES Insulation Act. ' Type Frame Area U -Fac. Cay. Cont. Azm. Tilt nnf Wnnd 1 436 n n?� R_3R R_n 0 925 17 Wall Wnnd 34n n n74 R-19 R o n _gn gn wall Wnnd 308 n n74 R_19 RR -fl 0 180 gn Wall wood 11x2 _Q_Q74 R_1QR-Q()?7n so Wall Wnnd 32nn74 R-19 R 0.0 1An An FinnrRr, None 761 n 73o Nnne R-0 0 n 1A0 WaIIRG Npne 837 n 650 Nnne R_n n n g0 nnf Wnnd 1717 n 125 R -3R R_n n 225 17 Wall Wnnd 105 0 074 R-19 R-0 0 41; gn Wall Wnnd A7 n 074 R-19 R-0 0 135 An Wall Wnnd 58 n 074 R_19 R_n n 4.5 gn Wall Wnnd 1n3 n Q74 R-19 R -n n 135 gn Wall Wnnd 66 n_o7a R_1q R -o n 225 An Wall Wnnd 80 0 074 R-19 R_n n 135 An Wall Wnnd 2n n_074 R_19 R-0 0 999; An Wall Wnnd 132 a n74 R_19 R -n_0 315 An Wall wand RR p Q7d R_19 R_n n 4!; An Wall ` wood 65 _0 074_ R_19 R_n 0 315 -90 Wall Wnnd 33 0074 R_19_ R_n 0 97f; _gn ' Wall Wnnd 168 1.074 R-19 R_0 0 315 _9Il Wall Wnnd Al 1174 R_19 R-11 315 qQ Wall Wnnd 64 1174 R_19 R-1.0 4S An Wall Wnnd 93 0 074 R-19 R-1.0 135 gn Wall Wnnd 64 0 074 R_19 R_1 n 225 go Rnnf wood 763 X10295 R-38 R-1 n 225 17 5.47 7.6% Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: # of Thermostat Units Zone Type Type 016 Conditioned Setback - 0 Oq Cnnditinned Setback 0_20 Conditioned Setback n.n9 Conditioned Setback 8,760 nla 565 8,195 12.3 1.00 2 ft2 ft2 ft2 ft2. ft Vent Hgt. Area -8 n/a B n/a $ n/a 8 n/a Gains Condition Y / N Status JA IV Reference Location / Comments EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 08092007A Page:3 of 25 1 Certificate Of Compliance: Residential (Part 1 of 4) CF-1 R v Villa At Madison Main Resedence 8/14/2007 Project Title Date I of 46A The Madison ('h lb IQuinta Project Address Building Permit # .Fnerav nriyen Solutions Inr. (760) 774-3676 Docume�i tai ion Author Telephone plan Check/Date EneraVPro Comp�ce Method • CA (:Iimatt-70ne15 Climate Zone I Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.71 3.40 0.31 Space Cooling 57.52 49.77 7.75 Fans 8.24 9.15 -0.91 Domestic Hot Water 2.76 4.25 -1.49 Pumps 0.00 0.18 -0.18 Totals 72.23 66.76 5.47 Percent better than Standard: 7.6% Building Type: W Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: Area: 1,770 ft2 Ratio: 20.2% ❑ Addition ❑ Existing + Add/Alt (W) 270 deg Natural Gas Avg. U: Avg. SHGC: BUILDING ZONE INFORMATION Zone Name 0.41 0.46 Floor Area Volume OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Wnnd 72 0 074 R_1g R_n n 135 _go Wall Wnnd 20 0074 R_19 R-0_0 22F; PQ Wall Wnnd 209 n 074 R_19 R-0_0 180 An Wall Wnnd 2n4 n n74 R_19 R -n n 27n An Door None 24 n Snn None R-0.0 27n An Wall Wnnd 152 n n74 R-19 R_n a x_90 Wall Wood 5n n n74 R_19 R -n o _22580 wall wood 56 _0074 R-19 R-0 d-315 go Rnnf Wnnd 1,554 n 025 R_38 R -n n 225 14 Wall Wnnd 124 a n74 R_19 R -n 0 22SgQ Wall wood 2n n n74 R_19 R -n n iso An Wall Wnnd 123 p 074 R-19 R -o o 27n An Wall Wnnd 9A n n74 R-19 R_n a 18n An Wall Wnnd 131 n n74 R-19 R -n 0 _0 An Wall Wnnd 15 n n74 R_19 R -o o 27n _990 Wall Wnnd ins n_n74 R-19 R_n n 0 An Wall Wnnd 30 p 074 R_19 R_0 n gn gp Wall Wnnd 191 o 074 R_19 R -n n _0 90 noon NnnP 24 0500 Incid R_n 0 _D 90 Rnnf Wnnd 1-134 _n 025 R --1A R -n n 225 14 Wall Wnnd 343 n n74 R_1A R_0 n n An Wall Wood 26 n n74 R_19 R -n n An _g0 Wall Wnnd 174 n n74 R_ A R-0 n n An Wall Wnnd 111 p n74 R_1A R -n n go g0 Wall Wnnd 173 0 074 R_19 R -n n 18n An Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: # of Units Thermostat Zone Type Type Conditioned Setback CnnditinnPd Sethack Conditioned Setback 8,760 ft2 n/a ft2 565 ft2 8,195 ft2 12.3 ft 1.00 2 Vent Hgt. Area -H n/a S n/a n/a Gains Condition Y / N Status JA IV Reference Location / Comments EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 08092007A Page:4 of 25 1 Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R v Total Conditioned Floor Area: Villa At Madison Main Residence ❑ Multi Family 8/14/2007 Project Title n/a ft2 Building Front Orientation: Date I ntA6AThe Madisonsltih I a Quinta ft2 Fuel Type: Project Address Slab on Grade Area: 8,195 ft2 Building Permit # Enerav Driven Snlutinns Inr Average Ceiling Height: (760) 774-3676 ft Docume tion Author 1,770 ft2 Avg. U: 0.41 Telephone plan Check/Date EneravPrn Compll ce Method Ratio: (.A Climate 7nne 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance Vent (kBtu/sf-yr) Design Design Margin Hgt. Space Heating 3.71 3.40 0.31 Space Cooling 57.52 49.77 7.75 Fans 8.24 9.15 -0.91 Domestic Hot Water 2.76 4.25 -1.49 Pumps 0.00 0.18 -0.18 Totals 72.23 66.76 5.47 Percent better than Standard: 7.6% Building Type: Single Family ❑ Addition Total Conditioned Floor Area: 8,760 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (W) 270 deg Raised Floor Area: 565 ft2 Fuel Type: Natural Gas Slab on Grade Area: 8,195 ft2 Fenestration: Average Ceiling Height: 12.3 ft Area: 1,770 ft2 Avg. U: 0.41 Number of Dwelling Units: 1.00 Ratio: 20.2% Avg. SHGC: 0.46 Number of Stories: 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Wnnd 78 n n74 R_19 R -n n n go Wall Wnnd 748 n n74 R-19 R-n_n An An Rnnf Wnnd 1 195 n n2f R_38 R -n o 92f; 17 Floor Wood 5ri5 n n34 R_ -An R -n n _aigQ Wall Wnnd an n n74 R_ A R -n n 315 _go Wall Wnnd so n n74 R_19 R -o n 775 gn wall Wood_ 17x1 _n 074 R-19 R -n o 97n gn r)0pr None 41; _o Soil Nnne R_n n?7n An Wall Wnnd r,0 n n74 R-19 R -n n 315 _go Wall Wnnd 7n n n74 R_19 R -n n 92,9i An Wall wood 994 n n74 X19 R_n n 11.9; —gn Lyall WOOd g7 n (174 R-19 R-0 0 Ori -9Q Wall Wnnd R8 n n74 R_19 R_n n 135 _go Wall Wnnd RS 0 074 R-19 R-n_n _9;) -Si Wall Wnnd 141 n n74 R_19 R_n o 135 _qr) Wall Wnnd 198 n n74 R-19 R -o o 975 An Wall Wnnd 139 n n74 R_19 R -n n 315 go Wall Wnnd 198 o n74 R_19 R -n o cin g0 Wall Wnnd 93n 0 074 R_19 R -o n n gn Gains Condition Y / N Status JA IV Reference Location / Comments ® ❑New ng -AS Zone 3 IN New M -AS Zone 3 IN ❑New 01-AlR Znne 5 ❑ New 91-A7 Znne 5 IN ❑New ng -AS Znne 5 ® ❑New OA -AS Znne 5 ® ❑New 09_AS 7nne 5 ® F-1 New 98-A4 Znne 5 ® ❑New 09 -AS Znne 5 ® ❑New 09-A5 Znne 5 ® New n9 -A5 7nne 5 IN New 09-A5 Zone.'; IN ❑New ng -AS Znne 5 ® ❑New 09 -AS Znne 5 IN ❑Mew n9 -AS Znne 5 ® ❑New Ilg-AS Znne 5 IN ❑New 09-A5 Znne 5 DQ [—]New 09-A5 Znne 5 ® ❑New ng -A5 7nne 5 EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 08092007A Paae:5 of 25 1 31ab Perimeter 112 None No Insulation 26-A1 New Zone 3 Run Initiation Time: 08/14/07 09.54.55 Run Code,• 1187110495 EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 08092007A Page:6 of 25 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R 1` Villa AiMadison Main Residence 8/14/2007 Project Title Date ' FENESTRATION SURFACES True Cond. Location/ # • Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments ]_ Window Rear (E) inn (L n 4A0 116-A J10 11Fi-B Pin __qD_ New Weiland Sliding Panelc DuI/Ln F Zone 4 ' 2 Window Right (S) 140.0 0.480 116-A 0_65 116-B 180 90 New Weiland Sliding Panels Dual/Lo E Zone 4 5 Window Right (S) 37.4 0.340 NFRC ' 0 28 NFRC 180 90 New Loewen DbIM/d Mticlad Low -E Zone 4 4 Window Left (NE) 15.0 0.340 NFRC 0_28 NFRC 45 90 New Loewen Dbl/Wd Mticlad Low -E Zone 7 5 Window Left (NE) 15.0 0.340 NFRC 0_28 NFRC 45 90 New Loewen Dbl/Wd Mticlad Low -E Zone 7 ' 5 Window Rear (SE) 24.0 0_340 NFRC 0_28 NFRC 135 90 New Loewen MAW Mticlad Low -E Zone 7 L Window Rear (SE) 20.0 0=340 NFRC 0_28 NFRC 135 __9_Q New Loewen Dbl/Wd Mticlad Low -E Zone 7 8 Window Rear (SE) 24.0 0.340 NFRC 0_28 NFRC 135 90 New Loewen Dbl/Wd Mticlad Low -E Zone 7 5 Window Left _(NE) 63.3 0=480 116-A _0.65 116-B 45 -9Q New Weiland Sliding Panels Dual/Lo E Zone 7 1Q Window Rear (SE) 150.0 0_480 116-A 0=65 116-6 135 __cKL New Weiland Sliding Panels Dual/Lo E Zone 7 ' 11 Window Rear (SE) 90.0 0_340 NFRC 0_28 NFRC 135 90 New Loewen DblANd Mticlad Low -E Zone 7 ' 12 Window Front (NW) 1.5 0.340 NFRC 0_28 NFRC 315 90 New Loewen Dbl/Wd Mticlad Low -E Zone 7 Aa Window Front (NW) 1.5 0_340 NFRC 0_28 NFRC 315 _g.0_ New Loewen DbIM/d Mticlad Low -E Zone 7 14 Window Front (NW) 1.5 0.340 NFRC 0_28 NFRC 315 90 New Loewen Dbl/Wd Mticlad Low -E Zone 7 ' 15 Window Front (NW) 1.5 0.340 NFRC 0_28 NFRC 315 90 New Loewen Dbl/Wd Mticlad Low -E Zone 7 6 Window Front (NW) 1.5 0.340 NFRC 0_28 NFRC 315 90 New Loewen Dbl/Wd Mticlad Low -E Zone 7 1 Window Left (NE) 12.0 0.340 NFRC 0_28 NFRr 45 90 New Loewen Dbl/Wd Mticlad Low -E Zone 7 r I JA Window Right (SW) 24.0 0.340 NFRC 0_28 NFRC 225 90 New Loewen Dbl/Wd Mticlad Low -E Zone 7 J1 Window Front (NW) 8.0 0_340 NFRC 0_28 NFRC 315 -9Q New Loewen Dbl/Wd Mticlad Low -E Zone 7 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1166. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type ` SHGC Hgt. Wd. Len. Hgt. LExt. REM. Dist. Len. Hgt. Dist Len Hgt. 1 Bug Screen 0.76 10.0 30.0 10.0 0.1 10.0 10.0 2 Bug Screen 0.76 10.0 14.0 10.0 0.1 10.0 10.0 3 Bug Screen 0.76 8.0 4.7 10.0 0.1 10.0 10.0 ' 4 Bug Screen 0.76 ' 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 .' 8 Bug Screen 0.76 8.0 3.0 10.0 0.1 10.0 10.0 9 Bug Screen 0.76 10.0 6.3 10.0 0.1 10.0 10.0 10 Bug Screen 0.76 10.0 15.0 10.0 0.1 10.0 10.0 11 Bug Screen 0.76 ' 12 Bug Screen 0.76 1.5 1.0 10.0 0.1 10.0 10.0 13 Bug Screen 0.76 1.5 1.0 10.0 0.1 10.0 10.0 14 Bug Screen 0.76 1.5 1.0 10.0 0.1 10.0 10.0 15 Bug Screen 0.76 1.5 1.0 - 10.0 0.1 10.0 10.0 16 Bug Screen 0.76 1.5 1.0 10.0 0.1 10.0 10.0 ' 17 Bug Screen 0.76 4.0 3.0 10.0 c 0.1 10.0 10.0 18 Bug Screen 0.76 8.0 3.0 10.0 0.1 10.0 10.0 19' Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type ' (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Masonry, Block Infil 837 6.00 17 0_36 2 12-A9 New Zone 6 / Exterior Mass - PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments ' ' Slab Perimeter - 86 None No Insulation 26-A1 New Zone 4 Slab Perimeter 145 None No Insulation 26-A1 New Zone 7 Slab Perimeter 64 None No Insulation 26-A1 New Zone 8 ri Slab Perimeter 77 None No Insulation 26-A1 New Zone 2 31ab Perimeter 112 None No Insulation 26-A1 New Zone 3 Run Initiation Time: 08/14/07 09.54.55 Run Code,• 1187110495 EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 08092007A Page:6 of 25 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Villa At Madison Main Residence 8/14/2007 Project Title Date Insulation ' FENESTRATION SURFACES Location/ Type Length R -Val. Location JA IV Reference True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments 2a Window Front (NW) R_0 n 34DNFRr 0_28 NF$r 315 __q()_ NPw I oewen r)hl=d Mtlrlari I nw-F Znn, 7 ' 21 Window Front (NW) 8.0 0.340 NFRC 0_28 NFRC 315 90 New Loewen DbIANd Mticlad Low -E Zone 7 22 Window Front (NW) 8.0 0.340 NFRC 0_28 NFRC 315 90 New Loewen DbIM/d Mticlad Low -E Zone 7 23 Window Front (NW) 4.0 0.340 NFRC 0_28 NFRC 315 90 New Loewen DbIANd Mticlad Low -E Zone 7 34 Window Front (NW) 4.0 0.340 NFRC 0_28 NFRC 315 90 New Loewen Dbl/Wd Mticlad Low -E Zone 7 ' 2d Window Front (NW) 4.0 0_340 NFRC 0_28 _NFRC 315 90 New Loewen DbIANd Mticlad Low -E Zone 7 2fi Window Left (NE) 4.0 0=340 NFRC _U8 NFRC 45 9Q New Loewen DbIM/d Mticlad Low -E Zone 7 27 Window Rear (SE) 4.0 0.340 NFRC 0_28 NFRC 135 90 New Loewen Dbl/Wd Mticlad Low -E Zone 7 2$ Window Rear (SE) 4.0 0_340 NFRC -0-28 NFRC 135 _9Q New Loewen DbIM/d Mticlad Low -F Zone 7 2;3 Window Rear (SE) 4.0 0_340 NFRC 0_28 NFRC 135 --cQ New Loewen Dbl/Wd Mticlad Low -E Zone 7 ' _Q Window Right (SW) 4.0 0_340 NFRC 0_28 NFRC 225 90 New Loewen DbIANd Mticlad Low -E Zone 7 31 Window Rear (SE) 8.0 0.340 NFRC 0_28 NFRC 135 90 New Loewen DbIANd Mticlad Low -E Zone 8 22 Window Front (NW) 4.0 0=340 NFRC J128 NFRC 315 __qD- New Loewen DhlMld Mticlad Low -F Zone 8 33 Window Right (SW) 11.0 0.340 NFRC 0_28 NFRC 225 90 New Loewen Dbl/Wd Mticlad Low -E Zone 2 ' 34 Window Front (W) 120.0 0.340 NFRC 0_28 NFRC 270 90 New Loewen DbIANd Mticlad Low -E Zone 2 35 Window Left (N) 72.0 0.340 NFRC 0_28 NFRC 0 90 New Loewen DbIANd Mticlad Low -E Zone 2 36 Window Left (N) 8.0 0.340 NFRC 0_28 NFRC 0 90 New Loewen DbIAA1d Mticlad Low -E Zone 2 37 Window Left (N) 18.0 0.340 NFRC 0_28 NFRC 0 90 New Loewen DbIANd Mticlad Low -E Zone 2 ' 2$ Window Left (N) 21.4 0_340 NFRC _0_28 NFRC 0 _9Q New Loewen DbIANd Mticlad Low -E lone 2 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. 'INTERIOR AND EXTERIOR SHADING window Overhang Left Fin Right Fin ' # Exterior Shade Type SHGC Hgt. Wd. Len. H t. LExt. REA Dist Len H t Dist Len Hgt 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 ' 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 ' 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 ' 31 Bug Screen 0.76 32 Bug Screen 0.76 2.0 2.0 10.0 0.1 10.0 10.0 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 ' 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Type Area Thick. Heat Inside (sf) (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 42 None No Insulation 26-A1 New Zone 5 Run Initiation Time: 08/14/07 09.54:55 Run Code: 1187110495 EnergyPro 4.3 by Energysoft User Number: 6168 Job Number: 08092007A Page:7 of 25 1 - Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R '-Villa At Madison Main Residence 8/14/2007 Project Title Date ' FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazinq Type Comments � I � I 39. 40 Window Window Left Left (N) 71 00n 34 NFRC 0_28 NFRC n Qf New Loewen r)hl=fi Mticlad Low -F (N) 21.0 0.340 NFRC 0_28 NFRC 0 90 New Loewen Dbl/Wd Mticlad Low -E Zone 3 Zone 3 41 Window Left (N) 86.0 0_340 NFRC 0_28 NFRC 0 90 New Loewen Dbl/Wd Mticlad Low -E Zone 3 42 Window Rear (E) 90.0 0.480 116-A 0_65 116-8 90 90 New Weiland Sliding Panels Dual/Lo E Zone 3 43 Window Right (S) 48.0 0.480 116-A 0_65 116-8 180 90 New Weiland Sliding Panels Dual/Lo E Zone 3 44 Window Rear (E) 72.0 0_480 11" _0_65 116_B 90 90 New Weiland Sliding Panels Dual/Lo E Zone 3 AS Window Front (YV) 5.0 0_340 NFRC 0_28 NFRC 270 ,9Q New Loewen Dbl/Wd Mticlad Low -E Zone 5 46 Window Front (W) 12.5 0.340 NFRC 0_28 NFRC 270 90 New Loewen Dbl/Wd Mticlad Low -E Zone 5 AZ g$. Window Window Front Front (VV) 12.5 0_340 NFRC _U8 NFRC 270 qQ New Loewen Dbl/Wd Mticlad Low -E (W) 5.0 0_340 NFRC 028 NFRC 270 __qQ New Loewen Dbl/Wd Mticlad Low -E Zone 5 Zone 5 A9 Window Rear (SE) 7.5 0_340 NFRC 0_28 NFRC 135 90 New Loewen Dbl/Wd Mticlad Low -E Zone -5 50 Window Rear (SE) 7.5 0.340 NFRC 0_28 NFRC 135 90 New Loewen DbIM/d Mticlad Low -E Zone 5 F.1 52 Window Window Rear Rear (SE) 3.8 0_340 NFRC 0_28 NFRC 135 __q0_ New Loewen Dbl/Wd Mticlad Low -F (SE) 3.8 0.340 NFRC 0_28 NFRC 135 90 New Loewen DbIM/d Mticlad Low -E Zone 5 Zone 5 53 Window Left (NE) 24.0 0.340 NFRC 0_28 NFRC 45 90 New Loewen Dbl/Wd Mticlad Low -E Zone 5 54 Window Rear (SE) 15.0 0.340 NFRC 0_28 NFRC 135 90 New Loewen DbIANd Mticlad Low -E Zone 5 55 Window Rear (SE) 20.0 0.340 NFRC 0_28 NFRC: 135 90 New Loewen DbIN11d Mticlad Low -E Zone 5 56 Window Rear (SE) 15.0 0.340 NFRC 0_28 NFRC 135 90 New Loewen Dbl/Wd Mticlad Low -E Zone 5 _5Z Window Rear (SF). 2.0 0_340 NFRC 0_28 NFRC 135 _9Q New Loewen Dbl/Wd Mticlad Low -E Zone 5 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin ' Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 39 Bug Screen 0.76 40 Bug Screen 0.76 41 ' Buq Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 8.0 6.0 10.0 0. 10.0 10.0 44 Bug Screen 0.76 8.0 9.0 10.0 0. 10- 10-0 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 Bug Screen 0.76 49 Bug Screen 0.76 5.0 1.5 8.0 0.1 8.0 8.0 50 Bug Screen 0.76 5.0 1.5 8.0 0.1 8.0 8.0 51 Bug Screen 0.76 52 Bug Screen 0.76 53 Bug Screen 0.76 _ 54 Bug Screen 0.76 _ 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Buq Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation TvDe Length R -Val. Location JA IV Reference Condition Location/ Status Comments Run Initiation Time: 08/14/07 09.54.55 Run Code: 1187110495 EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 08092007A Page:8 of 25 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Villa At Madison Main Residence Project Title Date ' 8/14/2007 FENESTRATION SURFACES True Cond. # Type Area LI -Factor" SHGC2 Azm. Tilt Stat. Glazing Type Location/ Comments �$ Window Rear (,SF) 2 a X340 NFRC 0 .8 NFRC 135 _2Q New Lnewen DbIANd Mtlr nd I nw-F 59 Window Front (NW) 8.0 0.340 NFRC 0_28 NFRC 315 90 New Loewen Dbl/Wd Mticlad Low -E Znne 5 Zone 5 60 Window Front (NW) 8.0 0.340 NFRC 0_28 NFRC 315 90 New Loewen Dbl/Wd Mticlad Low -E Zone 5 61 Window Front (NW) 8.0 0.340 NFRC 0_28 NFRC 315 90 New Loewen Dbl/Wd Mticlad Low -E Zone 5 §� Window Front (NW) 8.0 0.340 NFRC 0_28 NFRC .315 90 New Loewen Dbl/Wd Mticlad Low -E Zone 5 Window Front (NW) 8.0 0_340 NFRC 0_28 _NFRC 315 gQ New Loewen MAN Mticlad Low -E Zone 5 _64 Window Left (N) 3.8 0_340 NFRC 0_28 NFRC — 0 —9D- New Loewen DbIANd Mticlad Low -E Zone 5 65 Window Left (N) 3.8 0.340 NFRC 0_28 NFRC 0 90 New Loewen Dbl/Wd Mticlad Low -E Zone 5 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist Len Hgt. 58 Bug Screen 0.76 59 Bug Screen 0.76 60 Bug Screen 0.76 61 Bug Screen 0.76 62 Bug Screen 0.76 63 Bug Screen 0.76 64 Bug Screen 0.76 65 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside a Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Condition Insulation Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 08/14/07 09.54.55 Run Code: 1187110495 EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 08092007A Page: 9 of 25 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R Villa At Madison Main Residence 8/14/2007 Project Title Energy Tank Insul. Water Heater Date Cap. Condition Factor HVAC SYSTEMS System Name Type Distribution Syst. (Btu/hr) (al) Status or RE Loss (%) Ext A O Smith Water Products CTG -50- Small Gas Recirc/Time+Temp Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Zone 4 HVAC System Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER New Setback Zone 6 HVAC System Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER New Setback Zone 7 HVAC System Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Zone 4 HVAC System Ducted Ducted Attic 8.0 New Yes Zone 6 HVAC System Ducted - Ducted Conditioned 8.0 New Yes Zone 7 HVAC System Ducted Ducted Attic 8.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (al) Status or RE Loss (%) Ext A O Smith Water Products CTG -50- Small Gas Recirc/Time+Temp 1 37,000 50 New 0.62 n/a n/a Smith Water Products FPSH-75 Large Gas Recirc/Time+Temp I 80 000 74 New 0.78 1.91% 0.0 A O Smith Water Products CTG -5D- Small Gas Recirc/Time+Temp 1 37 000 50 New 0.62 n/a n/a AWti-Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS copyright Contents 2007 Energy Driven Solutions COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Benjamin Hertz, Architect Address: 645 Oleander Road Palm Springs, CA 92264 Telepho e:�76�0-320-1�644. C D (signatur) • (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Dave Bricker Title/Firm: Enerqy Driven Solutions Inc Address: P. O. Box 6705 La Quinta CA 92248 Telephone: 760 774-3676 ` (signature) (date) r Cr.- rr A -B -E c C;ffxl 8W.--IrlEmrgyCms uk* CERTIFIED ENERGY ANALYST DAVE BRICKER EnergyPro 4.3 by EnergySoft User Number: 6168 Jnh Numher• nAnQ9nn7A . o-- In -f ')C I Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Villa At Madison Main Residence Ducts Location Heating 8/14/2007 Project Title R -Value Status Tested? Date Ducted Ducted HVAC SYSTEMS Heating Location Type Minimum Eff Cooling Type Minimum Eff Condition Status Thermostat Type Zone 8 HVAC System Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER New Setback Zone 2 HVAC System Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER New Setback Zone 3 HVAC System Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER New Setback HVAC DISTRIBUTION Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated 'Tank Energy Tank Insul. ' Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (al) Status or RE Loss (%) Ext Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS Copyri ght Contents 2007 Energy Driven Solutions COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. ' The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Dave Bricker ' Title/Firm: Benjamin Hertz, Architect Title/Firm: Energy Driven Solutions Inc Address: 645 Oleander Road Address: P. O. Box 6705 Palm Springs, CA 92264 La Quinta CA 92248 ' Telephone: 760-320-1644 Lic. #: Telephone: 760 774-3676 (signature)/ (date) (signature) (date) r^ Enforcement Agency r r Name: C ,(� rc Title/Firm: A ,j/�� ' Address: CaAI lAssocla�crt�Btrr gEnertb►t�ar�Ub* Telephone: CERTIFIED ENERGY ANALYST DAVE BRICKER ' (signature) (date) Run I *tiat*on Time* 08114107 09:54:55 Run Code- 1187110495 Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Zone 8 HVAC System Ducted Ducted Attic 8.0 New Yes Zone 2 HVAC System Ducted Ducted Attic 8.0 New, Yes Zone 3 HVAC System Ducted Ducted Attic 8.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated 'Tank Energy Tank Insul. ' Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (al) Status or RE Loss (%) Ext Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS Copyri ght Contents 2007 Energy Driven Solutions COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. ' The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Dave Bricker ' Title/Firm: Benjamin Hertz, Architect Title/Firm: Energy Driven Solutions Inc Address: 645 Oleander Road Address: P. O. Box 6705 Palm Springs, CA 92264 La Quinta CA 92248 ' Telephone: 760-320-1644 Lic. #: Telephone: 760 774-3676 (signature)/ (date) (signature) (date) r^ Enforcement Agency r r Name: C ,(� rc Title/Firm: A ,j/�� ' Address: CaAI lAssocla�crt�Btrr gEnertb►t�ar�Ub* Telephone: CERTIFIED ENERGY ANALYST DAVE BRICKER ' (signature) (date) Run I *tiat*on Time* 08114107 09:54:55 Run Code- 1187110495 Certificate Of Compliance: Residential - (Part 3 of 4) CF -1 R Villa At Madison Main Residence 8/14/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Zone 5 HVAC System Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Zone 5 HVAC System Ducted Ducted Attic 8.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (al) Status or RE Loss (%) Ext ' Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS Copyright Contents 2007 Energy Driven Solutions COMPLIANCE STATEMENT This certificate of compliance lists the building features. and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Benjamin Hertz, Architect Address: 645 Oleander Road Palm Springs, CA 92264 Telephone: 760-320-1644 Lic. #: C -L$06 -C, S o� (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: I(signature) (date) Run Initiation Time: 08114/07 09 Documentation Author Name: Dave Bricker Title/Firm: Energy Driven Solutions Inc Address: P. O. Box 6705 La Quinta CA 92248 Telephone: 760 774-3676 (signature) (date) r rr CA BE C l��rrrta_ bnot LuVngE!lO nsuhift CERTIFIED ENERGY ANALYST DAVE BRICKER Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Villa At Madison Main Residence 8/14/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan Field The DHW Svstem "A O Smith Water Products FPSH-75" is a Large Gas water heater with Pilot Loss = 0 btuh. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field The HVAC System "Zone 4 HVAC System" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The Cooling System "York CZE048/PV8C20/G1 FA060" includes credit for a 12.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "Zone 6 HVAC System" has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System "Zone 6 HVAC System" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The Cooling System "York CZE24/PV8A12080/G1 FA30 " includes credit for a 13.1 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "Zone 7 HVAC System" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The Cooling System "York CZE048/PV8C20/G1 FA060" includes credit for a 12.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "Zone 8 HVAC System" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The Cooling System "York CZE24/PV8A12080/G1 FA30 " includes credit for a 13.1 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "Zone 2 HVAC System" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The Cooling System "York CZE036/PV8B16/G1 FA048" includes credit for a 12.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "Zone 3 HVAC System" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The Cooling System "York CZE48/PV8C20100/G1 FA60 " includes credit for a 12.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "Zone 5 HVAC System" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 08092007A Page:13 of 25 1 Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R ' Villa At Madison Main Residence 8/14/2007 Project Title Date ' Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local, enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies ' HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS rov'der s' d t t' Al 'f h p i u mg approve es mg an or ver ;91. 6'. met ods. Plan Field The Cooling System "York CZE36/PV8B16100/G1 FA48 " includes credit for a 12.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. ' r ( I Run Initiation Time: 08/14/07 09:54:55 Run Code: 1187110495 EnergyPro 4.3 by, EnergySoft User Number: 6168 Job Number: 08092007A Page: 14 of 25 I 1 J Mandatory Measures Summary: Residential (Page 19f 2) MF -1 R NOTE:' Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures *§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑' ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: ) a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ` ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X - ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑ ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ' ❑ ❑X ❑ § 150(h): Heating. and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. J 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal 'resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external /^ ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. _ 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to. Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between.heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind. _6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑� entirely in conditioned space. L J 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 08092007A Page: 15 of 25 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ 0 ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 1818 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. `2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than❑ X❑ ❑ sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. i 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ 2 ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ 2 ❑ f 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ` ❑ - dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ 2 ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ® ' ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ X❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ 2 ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ 2 ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ X❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are❑ X❑ ❑ controlled by an occupant sensor that complies with Section ll 19(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are❑ X❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ © ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 08092007A Page:16 of 25 Residen+tial Kitchen Lighting Worksheet WS -5R tVilla At Madison Main Residence 8/14/2007 Project Title ' Date ' At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. ' Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts ' L) 26w Compact. Fluorescent Triple 4 Pin Yes X No F 28.0 x 14 Yes No _ 392 or ` Elec x or Yes No x = or Yes No x = or ' Yes No x or Yes No x or Yes No x = or Yes No x _ or ' Yes No x _ or. Yes No x or Yes No- x - or Yes No x = or ' ' Yes No x = or Yes No x or Yes No x = or Yes No x = or + i. Yes No x or ' Yes No x or Yes No x or Yes No (x = or 1 Total A: 392- B: 0 I COMPLIES IF A;-,. B YES ® NO ❑ f 1 1 + (A", 1 � ' i 1 � 1 EnergyPro 4.3 by Energysoft User Number: 6168 Job Number: 08092007A Page: 17 of 25 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Villa At Madison Main Residence 8/14/2007 SYSTEM NAME FLOOR AREA Zone 4 HVAC System 1,436 Number of Systems 1 Heating System Output per System 80,000 Total Output (Btuh) 80,000 Output (Btuh/sgft) 55.7 Cooling System Output per System 47,100 Total Output (Btuh) 47,100 Total Output (Tons) 3.9 Total Output (Btuh/sgft) 32.8 Total Output (sgft/Ton) 365.9 Air System CFM per System 1,610 Airflow (cfm) 1,610 Airflow (cfm/sgft) 1.12 Airflow (cfm/Ton) 410.2 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 of 69.2 of Outside Air 0 0 cfm Supply Fan 1610 cfm 69.2 of 11.0/77.60F >--- J Outside Air 0 cfm 77.3/62.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 1,232 27,153 2,107 482 23,107 0 2,303 1,412 0 0 0 0 0 0 0 0 0 2,3031 1 11412 31,75:9=2 107 =i;30 York CZE048/PV8C20/G 1 FA060 40,085 0 80,000 Total Adjusted System Output ao,085 0 80,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am RICS (Airstream Tei 69.2 OF n 115.90F Heating Coil h Return Air Ducts `i 77.3 / 62.0 of 77.3 / 62.0 of M 53.9/52.70F Supply Fan 1610 cfm Cooling Coil h Return Air Ducts "I Supply Air Ducts 115.0 of ROOMS 70.0 of Supply Air Ducts 55.3/53 . 3 of 43.9% R.H. ROOMS 76.0 / 61.5 of I EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 08092007A . Page: 18 of 25-1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Villa At Madison Main Residence 8/14/2007 SYSTEM NAME FLOOR AREA Zone 6 HVAC Svstem 7A1 Number of Systems 1 Heating System Output per System 64,000 Total Output (Btuh) 64,000 Output (Btuh/sqft) 84.1 Cooling System Output per System 23,600 Total Output (Btuh) 23,600 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 31.0 Total Output (sgft/Ton) 386.9 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sqft) 1.05 Airflow (cfm/Ton) 406.8 Outside Air (%) 0.0 Outside Air (cfm/sgftj 0.00 Note: values above given at ARI conditions .ATING SYSTE 26.0 of Outside Air 0 cfm 67.7 of 11.0 / 77.6 of )� Outside Air 0 cfm 76.2/61.8 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK I CFM Sensible Latent CFM Sensible 4 80 1,1171 53 841 York CZE24/PV8A12080/G1FA30 20,245 0 64,000 Total Adjusted System Output 20,245 0 64,000 (Adjusted for Peak Design Conditions) 67.7 of 69.7 of 144.8 of 0 Supply Fan Heating Coil 800 cfm TIME OF SYSTEM PEAK I Aug 2 pm I I Jan 12 am of H Return Air Ducts ROMETRICS (Airstream Temperatures at Time of Cc 76.2/61.8OF 78.2/62.5OF 54.4/53.1OF Supply Fan Cooling Coil 800 cfm Return Air Ducts 4.3 by EnergySoft User Number: 6168 Job Number: 08092007A Supply Air Ducts 142.5 of ROOMS 70.0 of Supply Air Ducts 54.6 / 53.2 of 44.6% R.H. ROOMS 76.0 / 61.7 of 19 of 25 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Villa At Madison Main Residence 8/14/2007 SYSTEM NAME FLOOR AREA Zone 7 HVAC Svstem 1 717 Number of Systems 1 Heating System Output per System 80,000 Total Output (Btuh) 80,000 Output (Btuh/sqft) 46.6 Cooling System Output per System '47,100 Total Output (Btuh) 47,100 Total Output (Tons) 3.9 Total Output (Btuh/sgft) 27.4 Total Output (sgft/Ton) 437.5 Air System CFM per System 1,610 Airflow (cfm) 1,610 Airflow (cfm/sgft) 0.94 Airflow (cfm/Ton) 410.2 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note:. values above JEATING SYSTE 26.0 OF Outside Air 0 cfm 69.0 of COOLING S 111.0 / 77.6 of )� Outside Air 0 cfm 77.4/62.10F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFMJSensibIe1 Latent CFMI Sensible 31.9 , 2 684 30,33i York CZE048/PV8C20/G I FA060 40,156 0 80,000 Total Adjusted System Output ao,156 o So,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am n at ARI conditions SYCHROMETRICS (Airstream Temperatures at 69.0 of 69.0 of 115.70F no Supply Fan Heating Coil 1610 cfm 77.4 / 62.1 OF 77.4 / 62.1 of h Return Air Ducts � kratures at Tim 53.9 / 52.7 of Supply Fan Cooling Coil 1610 cfm h Return Air Ducts 4 Supply Air Ducts 114.8 of ROOMS 70.0 of Supply Air Ducts 55.3 / 53.2 of 44.2% R.H. ROOMS 76.0 / 61.6 of EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number 08092007A Page: 20 of 25 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Villa At Madison Main Residence 8/14/2007 SYSTEM NAME FLOOR AREA Zone 8 HVAC Svstem 7F� Number of Systems 1 Heating System Output per System 64,000 Total Output (Btuh) 64,000 Output (Btuh/sgft) 83.9 Cooling System Output per System 23,600 Total Output (Btuh) 23,600 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 30.9 Total Output (sgft/Ton) 388.0 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.05 Airflow (cfm/Ton) 406.8 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions .ATING SYSTEM PSYCHROME 26.0 of 69.3 -OF Outside Air 0 0 cfm Supply Fan 800 cfm 69.3 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent I Sensible 280 6,174 1,120 115 9,315 0 524 569 0 0 0 0 0 0 0 1,675 -1,675 524 569 8 896 1 120 8 778 York CZE24/PV8A12080/G1 FA30 20,337 0 64,000 Total Adjusted System Output 20,337 0 64,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am RICS (Airstream Tem 71.30F r 146.5 OF • ISI Heating Coil h Return Air Ducts 'I Supply Air Ducts 145.8 of ROOMS 70.0 of V.UU.LiNG 5Y5TEM P5YCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6OF 76.6/62.1OF 78.6/62.8OF 54.7/53.4OF O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 55.3 / 53.7 of 800 cfm 45.1% R.H. ROOMS 76.6/62.10F 76.0/61.9OF h Return Air Ducts `i EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 08092007A Page:21 of 25 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY ' PROJECT NAME DATE Villa At Madison Main Residence 8/14/2007 SYSTEM NAME FLOOR AREA ' Zone 2 HVAC System 1,554 [ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 80,000 Total Output (Btuh) 80,000 Output (Btuh/sgft) 51.5 Cooling System Output per System 35,500 Total Output (Btuh) 35,500 Total Output (Tons) 3.0 Total Output (Btuh/sgft) 22.8 Total Output (sgft/Ton) 525.3 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sgft) 0.77 Airflow (cfm/Ton) 405.6 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts COIL COOLING PEAKCOIL HTG. PEAK CFM Sensible Latent CFM Sensible 779 16,389 2,449 274 17,755 0 1,390 1,085 0 0 0 0 0 0 0 0 0 1,390 1,085 TOTAL SYSTEM LOAD 19170 2 44s 1s 924 HVAC EQUIPMENT SELECTION York CZE036/PV8B16/G1 FA048 28,040 2,567 80,000 Total Adjusted System Output 28040 25671So,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.2 OF 69.20 131.8 OF Supply Air Ducts Outside Air O 0 cfm ' 130.9 OF Supply Fan Heating Coil 1200 cfm ROOMS 69.2 °F 70.0 OF 1 Return Air Ducts ' DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 OF 77.1 / 62.8 OF 77.1 / 62.8 OF 55.1 / 54.0 OF ' O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 56.2 / 54.4 OF ' 1200 cfm 46.9% R.H. ROOMS 77.1/62.8 °F 76.0 / 62.4 OF do - Return Air Ducts EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number 08092007A Page:22 of 25 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Villa At Madison Main Residence 8/14/2007 SYSTEM NAME FLOOR AREA ' Zone 3 HVAC System 1,334 [ENGINEERING CHECKS ISYSTEM LOAD Number of Systems 1 Heating System Output per System 80,000 Total Output (Btuh) 80,000 Output (Btuh/sgft) 60.0 Cooling System Output per System 47,100 Total Output (Btuh) 47,100 Total Output (Tons) 3.9 Total Output (Btuh/sgft) 35.3 Total Output (sgft/Ton) 339.9 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sgft) 1.20 Airflow (cfm/Ton) 407.6 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 ' Note: values above given at ARI conditions EATING S ' 26.0 OF 0 Outs 0 cfm 1 69.3 OF ' OOLING S 111.0 / 77.6 OF 'Outside Air 0 cfm ' 77.4 / 62.5 °F EnergyPrc COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible Total Room Loads 1,314 Return Vented Lighting Return Air Ducts Return Fan Ventilation o Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 27,198 1,958 0 2,307 0 .0 0 3,086 2,307 34 898 1 958 York CZE48/PV8C20100/G1 FA60 40,822 0 80,000 Total Adjusted System Output ao,822 o so,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I Jan 12 am 69.3°F 71.10F 118.0°F Supply Fan Heating Coil 1600 cfm h Retum Air Ducts 4 r<um� ii rtws(Airstream i emperatures at emperatures at 77.4 / 62.5 OF 79.2/63.10F M 55.2/53.90F Supply Fan Cooling Coil 1600 cfm 4.3 by EnergySoft User Number: 6168 h Return Air Ducts �1 Job Number: 08092007A Supply Air Ducts 117.30F ROOMS 70.0 OF Supply Air Ducts 56.5 / 54.4 OF 45.6% R.H. ROOMS 76.0 / 62.0 OF of 25 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY - PROJECT NAME DATE Villa At Madison Main Residence 8/14/2007 SYSTEM NAME Zone 9 HVAC Svstem FLOOR AREA Zone 26.0 of 70.0 of Outside Air 0 0 cfm Supply Fan 766 cfm 70.0 of 71.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 16,9561 0 1 17,4651 Fujitsu 12CQ ductless split 20,530 0 0 Total Adjusted System Output 20,530 0 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 1110.00F Heating Coil h Return Air Ducts 'I Supply Air Ducts 110.0 of ROOMS 70.0 of UUiunta sTb I tM P bTUMKUMt I KicS Airstream Temperatures at Time of Coolin Peak 111.0/77.6 OF 76.0/60.2 OF 77.5/60.8 OF 52.3/51.0 OF O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 52.3 / 51.0 of 766 cfm 39.5% R.H. ROOMS 76.0/60.2 of 76.0 / 60.2 of h Return Air Ducts `i EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 08092007A i Page: 24 of 25 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY -PROJECT NAME DATE Villa At Madison Main Residence 8/14/2007 SYSTEM NAME FLOOR AREA 'Zone 5 HVAC System 1 195 [ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 80,000 Total Output (Btuh) 80,000 Output (Btuh/sqft) 66.9 Cooling System Output per System 35,500 Total Output (Btuh) 35,500 Total Output (Tons) 3.0 Total Output (Btuh/sgft) 29.7 Total Output (sgftfTon) 403.9 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sqft) 1.00 Airflow (cfm/Ton) 405.6 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 ' I Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 26.0°F 69.2°F 71.1°F ' Outside Air 0 cfm Supply Fan ' 1200 cfm 69.2 of ' OO LING SYSTEM 111.0 / 77.6 OF ' Outside Air 0 cfm 77.0/63.1 °F EnergyPro 4.3 by En Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 20,8851 1 929 CZE36/PV8B16100/G1FA48 28,948 2,164 80,000 Total Adjusted System Output 28 948 2 164 80,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm I I Jan 12 am 133.7 of Heating Coil 77.0/63.1°F 79.0/63.8°F 56.3/55.1°F Supply Fan Cooling Coil 1200 cfm User Number: 6168 Return Air Ducts `S' Job Number: 08092007A Supply Air Ducts 132.9 of ROOMS 70.0 OF I Supply Air Ducts 57.4 / 55.5 of 48.2% R.H. ROOMS 76.0 / 62.8 OF ui ca 77 TITLE 24 REPORT Title 24 Report for: Villa at Madison Detached Guest Suite Lot 46A, The Madison Club La Quinta, CA 92253 Project Designer: Benjamin Hertz, Architect 645 Oleander Palm Springs, CA 92264 i 760-320-1644 Report Prepared By: Dave Bricker Energy Driven Solutions Inc P. O. Box 6705 `La Quinta, CA 92248 (760) 774-3676 Job Number: 07272007A Date: 8/14/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: 07272007A User Number: 6168 TABLE OF CONTENTS r Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance .3 Form MF -1 R Mandatory Measures Summary 7 Form WS -5R Residential Kitchen Lighting g HVAC System Heating and Cooling Loads Summary 10 r _ 5 , EnergyPro 4.3 by EnergySoft Job Number: 07272007A User Number: 6168 Building Type: (Z Single Family ❑ Addition Total Conditioned Floor Area: ❑ Multi Family Certificate Of Compliance :.Residential (Part 1 of 4) CF -1 R Voila at Madison Detachedsuest Suite Project Title (S) 180 deg Raised Floor Area: 8/14/2007 Date of 4FA, The Madisonslub I a Quinta Natural Gas Slab on Grade Area: Fenestration: _I Project Address Average Ceiling Height: Building Permit # Fnerav Driven Solutions Inc Avg. U: 0.34 (760) 774-3676 Ratio: Docume tion Author Number of Stories: Telephone plan Check/Date ' -EneravPro CompliNrice Method CA C10mafe?one1 -5 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin ISpace Heating 2.29 2.48 -0.19 Space Cooling 81.92 90.95 -9.03 Fans 11.71 13.25 -1.54 Domestic Hot Water 22.54 10.07 12.47 Pumps 0.00 0.00 0.00 Totals 118.47 116.76 1.71 Percent better than Standard: 1.4% BUILDING COMPLIES - HERS VERIFICATION RFOUIRM Building Type: (Z Single Family ❑ Addition Total Conditioned Floor Area: ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: Building Front Orientation: (S) 180 deg Raised Floor Area: Fuel Type: Natural Gas Slab on Grade Area: Fenestration: Average Ceiling Height: Area: 218 ft2 Avg. U: 0.34 Number of Dwelling Units: Ratio: 29.2% Avg. SHGC: 0.28 Number of Stories: BUILDING ZONE INFORMATION # of Thermostat Zone Name Floor Area Volume 747 7�Rdd Units Zone Type Type 1 nn Conditioned Setback Zone 1H\/AC ';VSfpm OPAQUE SURFACES. Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rnnf Wand 747 n 075 R-38 R-0 0 775 14 Wall Wnnd 96 0 074 R_19 R-0 0 180 An Wall Wnnd R3 n p7-4 R_19 R-0.0 An 90 Wall Wnnd 19R 0 074 _19 R-0 0 n An Wall Wnnd 134 0 074 R_19 R-0.0 770 _$0 Wall Wnnd 44 0.074 R-19 R-0 0 0 g0 Wall Wood RS 0 074 R_19 R-0 0 77n gQ Wall Wood 349 _0 074 R-19 R -n 0 —0 ga Wall Wnnd 48 n 074 R_19 R_0 0 An An Wall Wnnd 110 n_074 R-19 R-0 0 0 _$0 Wall Wood 46 p n74 R_19 R -n n _gn g0 747 ft2 n/a ft2 0 ft2 747 ft2 10.5 ft 1.00 Vent Hgt. Area —� n/a Gains Condition Y / N Status JA IV Reference Location / Comments ® ❑New 01 -AIR Whnle HOUSP ®❑New 09-A5 Whnle House IN ::]New 09-A5 Whnle House ®❑New 109 -AS Whole House ® ❑New 09-A5 Whnle House ® ❑New 09-A5 Whnle Hnuse ® ❑New 09-A$ Whole House ® ❑New 119 -AS Whole House ® ❑Blew 119-A5 Whnle Hnuse ® ❑New 09-A5 Whnle Hnuse ® ONew 09-A5 Whole Houses EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 07272007A Paw:3 of 10 1 Certificate Of Compliance': Residential (Part 2 of 4) CF -1 R Villa at Madison Detached Guest Suite Project Title Date 8/14/2007 FENESTRATION SURFACES True Cond. # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Location/ Comments I Window Front (S) 24 0 n 34Q NFRC nn 9 NFRr 180 _gQ_ New Loewen MIAMI Mtlrlad I ow -F 2 Window Rear (N) 48.0 0.340 NFRC 0_28 NFRC 0 90 New Loewen Dbl/Wd Mticlad Low -E Whole House Whole House 5 Window Left (W) 21.0 0.340 NFRC 0_28 NFRC 270 90 New Loewen MAW Mticlad Low -E Whole House 4 Window Left (W) 21.0 0.340 NFRC 0_28 NFRC 270 90 New Loewen Dbl/Wd Mticlad Low -E Whole House 5 Window Left (W) 40.0 0.340 NFRC 0_28 NFRC 270 90 New Loewen Dbl/Wd Mticlad Low -E Whole House 5 Window Rear (N1 18.0 0_340 NFRC 0_28 NFRC 0 90New Loewen DbIANd Mticlad Low -E Whole House Z Window R(ght Oa 22.0 0_340 _NFRC 0_28 NFRC 90 --Q New Loewen DbIM/d Mticlad Low -E Whole House 8 Window Right (E) 24.0 0.340 NFRC 0_28 NFRC 90 90 New Loewen Dbl/Wd Mticlad Low -E Whole House 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Buq Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Type Area Thick. Heat Inside (sf) (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 234 None No Insulation 26-A1 New Whole House Run Initiation Time: 08/14/07 10.08.03 Run Code: 1187111283 EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 07272007A Page•4 of 10 r Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R Villa at Madison Detached Guest Suite 8/14/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Zone 1 HVAC System Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER New Setback HVAC DISTRIBUTION Duct - Duct Condition Ducts Location Heating—r Cooling Location - R -Value Status Tested? Zone 1 HVAC System Ducted Ducted Attic 8.0 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank. Energy Tank Insul. ' Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (al) Status or RE Loss (%) Ext Rheem RTG-42PVN Instant Gas Point of Use 1 118,000 0 New 0.84 0 n/a Multi -Family Central Water Heating Details Hot Water Pump - Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS Copyright Contents 2007 Energy Driven Solutions Inc COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design ' responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) t Name: Title/Firm: Benjamin Hertz, Architect Address: 645 Oleander Palm Springs, CA 92264 Telephone: 760-320-J644 Lic. #: <ZQ ' � 5•b (signature) (date) ' Enforcement Agency Name: Title/Firm: ' Address: Telephoner Documentation Author Name: Dave Bricker Title/Firm: Energy Driven Solutions Inc Address: P. O. Box 6705 La Quinta CA 92248 Telephone: 760 774-3676 (signature) (date) r rr CABEc CAffomlaAssoWft 0f9'J1VM, Lft r 0 CERTIFIED ENERGY ANALYST DAVE BRICKER (signature) (date) 0 nn na-Q7e Certificate Of Compliance .'Residential (Part 4 of 4) CF -1 R, Villa at Madison Detached Guest Suite 8/14/2007 Project Title Date - Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies ' HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS 'd prove er using approved testing and/or verification methods. Plan Field The HVAC System "Zone 1 HVAC System" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. i Run Initiation Time: 08/14/07 10:08:03 Run Code: 1187111283 ` EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 07272007A Page:6 of 10 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. , § 150(b): Loose fill insulation manufacturer's labeled R -Value: f§ 150(.): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls). ❑ o ❑ ❑ 0 ❑ ❑ ❑x ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑X ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ ❑ ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑ ❑ CF -6R Form: ` ❑ ❑ I ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/ExFltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. ' ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ' ❑ ❑ • having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1506. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ I ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must,be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 07272007A Page:7 of 10 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. n NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) J § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑X❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ X❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ® ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ I ® ❑ § 114: Pool and Spa Heating Systems and Equipment ` 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ X❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate.from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ X❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms ' shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section 1� 9(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ X❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6.' Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ X❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑' ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 07272007A Page:8 of 10 iY 1 • 1 Residential Kitchen Lighting Worksheet WS -5R Villa at Madison Detached Guest Suite 8/14/2007 Project Title ` Date ' At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts ' (1) 26w Compact Fluorescent Triple 4 Pin Yes X No 28.0 x' 3 _ 84 or Alec Yes No x or Yes No x = or Yes No x = or ' Yes No x or Yes No x or Yes No x = or Yes No x = or ' Yes No x or Yes No x or Yes No x = or Yes No x = or ' Yes No x or Yes No x or Yes No x = or Yes I No x = or ' Yes No x or Yes No x or Yes No x or Yes No x = or Total 'A: 84 B: 0 EnergyPro 4.3 by Energysoft User Number: 6168 COMPLIES IF A Z B YES ® NO ❑ Job Number: 07272007A Paw:9 of 10 1 � " HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY J PROJECT NAME DATE Villa at Madison Detached Guest Suite 8/14/2007 SYSTEM NAME FLOOR AREA Zone 1 HVAC Svstem 747 26.0 OF 67.7 OF Outside Air 0 cfm Supply Fan 800 cfm 67.7 of 69.6 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent I I CFM I Sensible 73 13,597 1,389 236 18,167 0 2,115 1,990 - 0 0 0 0 0 0 0 1,675 -1,675 2,115 1,990 19,5021 1 389 20 471 York CZE24/PV8A1 2080/G 1 FA30 20,779 0 64,000 Total Adjusted System Output 20,779 0 64,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 144.8 of Heating Coil K Return Air Ducts `i Supply Air Ducts 142.5 of ROOMS 70.0 of COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6OF 78.5/63.4OF 80.5/64.1OF 56.0/54.7OF O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 58.5 / 55.7 of 800 cfm 47.6% R.H. ROOMS 78.5/63.4 of 76.0 / 62.6 of h Return Air Ducts `S I EnergyPro 4.3 by EnergySoft User Number: 6168 Job Number: 07272007A Paae:10 of 10 1