BMCH2018-0074f..
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type/Subtype:
Application Number:
Property Address: .
APN:
Application Description
Property Zoning:
Application Valuation:
Applicant:
IE INC
31225 LA BAYA
WESTLAKE VILLAGE, CA 91362
4
DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
MECHANICAL/
BMC0074
549600 SHOAL CREEK PH�
775141060
STEARNS RESIDENCE / HVACOUT AR 2 0 2018
$12,875.00
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Owner:
SHERMAN STEAP.NS
4960 SHOAL CREEK
QU INTA, CA 52253
Date: 3/20/2018
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENISSER SERVICES NC DBA ESSER AIR CONDITI
P O BOX 1636 •
CATHEDRAL.CITY, CA 92235
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of. perjury that 1 am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C20 License No.: 489046
�.. o
�—Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5•by any applicant for a
permit subjects the applicant to a civil penalty, of not more than five hundred dollars
($500).:
(1 I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(1 I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(=) I am exempt under Sec. . B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
(760)324-0550
Llc. No.a 489046
WORKER'S COMPENSA7ION DECLARATION
I hereby affirm under penalty of perjury one cf the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 370] of the Labor Code; for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code,'for the perfoamance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD5030167
I certify.that in the performance ofthe work for which this permit is issued, I
shall not employ any person in any manner so -as to become subject to the workers'
compensation laws of California, and agree th at, if I should become subject to the
workers' compensation provisions of Section 2700 of the Labor Code, I shall forthwith
comply with those provisions.
c
Oar to Zn Ig e--Applicant:,�vcarz
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMIIIAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOt IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this: application.
1. Each person upon whose behalf this appli:ation is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of ssuance of such permit, or cessation of
work for 180 days will subject permit to canceflation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representacives of this city to enter upon the
above-mentioned property for inspection purfmses.
®MIM
u
Date: 3/20/2018
Application Number: BMCH2018-0074
Owner:
Property Address: 54960 SHOAL CREEK
SHERMAN STEARNS
APN: 775141060
54960 SHOAL CREEK
Application,Description: STEARNS RESIDENCE/ HVAC CHANGE OUT
LA QUINTA, CA 52253
Property Zoning:
Application Valuation: $12,875.00
Applicant:
Contractor:
IE INC
ESSER SERVICES NC DBA ESSER AIR CONDITI
31225 LA BAYA
P 0 BOX 1636
WESTLAKE VILLAGE, CA 91362
CATHEDRAL CITY, CA 92235
(760)324-0550
r Llc. No.: 489046
Detail: HVAC CHANGE OUT - 14 SEER/80 AFUE SPLIT.SYSTEM: CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TOS FINAL INSPECTION. PER 2016
CALIFORNIA BUILDING CODES.
FINANCIAL INFORMATION'
DESCRIPTION ACCOUNT CITY AMOUNT
BSAS SB1473 FEE 101-0000-20306 0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM
101-0000-42402
0
$39.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM PC
11 101-0000-42600
0
$78.02
Total Paid for CHANCEOUT: $117.03
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PERMIT ISSUANCE
101-0000-42404.
0
$98.83
Total Paid for PERMIT ISSUANCE: $98.83.
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $S.00
Contractor Name: Esser Services Inc.
PERMIT #
PLAN LOCATION: ,
Project Address•Project
54960 Shoal Creek
Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #:
Replace 4 ton / 100,000 BTU complete H`/AC system
Patio/Porch SF
Email:
Applicant Name: Steven Schnierer.
State Lic: 489046 City *Bus Lic:
Address: 31225 -La Baya Drive Suite 213
State Lic:City Bus Lic:
City, ST, Zip: Westlake Village, CA 91362
Telephone: 818-735-7876
Email:
swschnierer@roadrunner.com
Valuation of Project $ 12,875.00
Contractor Name: Esser Services Inc.
New SFD Construction:
Address: FO Box 1636
Conditioned Space SF'
City, St, Zip Cathedral City, CA 92235
Garage SF
Telephone: 760-324-0550
Patio/Porch SF
Email:
Fire Sprinklers SF
State Lic: 489046 City *Bus Lic:
Arch/Eng Name:
Construction Type: Occupancy:
Address:
Grading:
City, St, Zip
Construction Type: Occupancy:
Telephone:
Bedrooms:
Stories:
# Units:
Email:
State Lic:City Bus Lic:
Property Owner's Name: Sherman Stearns
New Commercial /Tenant Improveme ats:
Address: 54960 Shoal Creek
Total Building SF
City, ST, Zip La Quinta, CA 92253
Construction Type: Occupancy:
Telephone: 160-771-8496
Email:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
OFFICE USE ONLY
#
Submittal
Req'd
Rec'd'
Plan Sets
Structural Calcs
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM 10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License .
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) '(Page 1 of 3)
Project Name: SHERMAN STEARNS Date Prepared: 2018-03-20
A. General Information
CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF1R-ALT-02 document for each dwelling unit.
01
Project Name
SHERMAN STEARNS
02
Date Prepared
2018-03-20
03
Project Location
54960 SHOAL CREEK
04
Building Type
Single family
05
CA City
LA QUINTA r.<'}�y
:06
Dwelling Unit Name
SHERMAN STEARNS
SC System
SC System
CFA served
system a
refrigerant
07
Zip Code
92253 w
Installing:
Dwelling Unit Conditioned
-
1918
Location or Area
by this SC
3
X08
y .
2
floor Area (ft)
more than 40
entirely new
entirely new
, r
Served
System (ft2)
system?
component?
components?
feet of ducts?
Number of Space
SC system?
09
Climate Zone
15
10'
Conditioning (SC) Systems in
1
Yes
No
No
r..
this Dwelling Unit:
B. Space Conditioning (SC) System Information
jL n i F ? M
01
02
03
04 '
0 OS LU
LL.w 6"
07
08
09
10
Is the SC
Installing a
SC System
SC System
CFA served
system a
refrigerant
Installing new SC
Installing
Installing
Installing:
Identification or
Location or Area
by this SC
ducted
containing
system
more than 40
entirely new
entirely new
Name
Served
System (ft2)
system?
component?
components?
feet of ducts?
duct system?
SC system?
Alteration Type
SYSTEM 1
WHOLEHOUSE
1918
Yes
Yes
Yes
No
No
No
Altered space
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib)
This section does not apply to this, project.
Registration Number: 418-A020016953A-000-000-0000000-0000 Registration bate/time: 2018-03-20 08:56:02 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2018-03-20 08:56:04
Schema Version: rev 10/16
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)1E and F)
01
02
03
04'
0S
06
07
08
09
10
11
12
Heating
Cooling
System
Heating
Altered
Heating
Minimum
Altered
Cooling
Minimum
Required
New or
Identification
System
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct
or Name
Type
Components
Type
Value
System Type
Components
Type
Value
Type
Duct Length
R -Value
All new
All new
This field or
This field or
SYSTEM 1
Central gas
heating
AFUE
80
Central split
cooling
SEER
14
Setback
section is not
section is not
furnace
components
AC
components
applicable
applicable
Required Documentation:
CF2R-MCH-01-E Space Conditioning
- Systems
- Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums. `R6.(CZ•1-10 12 and13) and R8 (CZ 11 and 14-16)
CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in d'Ucted systems, or when more than 40 ft of dud length is replaced
-Leakage rate compliance: <= 15% or <=10% leakage to outside, or seal all accessible leaks. -- -'t (-
CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing coinponents:are Installed or altered (applicable In CZ 2, 8-15).
CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH -25 is required.
Exceptions:
Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing requirements.
Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MCH -25.
-Existing duct systems constructed,.insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements.
Ar— i if -ill 11 9(M i U-1) : K7
E. EntirelyNew or Complete Replacement Duct System, with orfwithout Eui ent Chan a ut Sections 150.2 b lDiia and 150.2 b lE F)
P p Y q p g ( () O,
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C)
This section does not apply to this project.
Registration Number: 418-A020016953A-000-000-0000000-0000 Registration bate/Time: 2018-03-20 08:56:02 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2018-03-20 08:56:04
Schema Version: rev 10/16
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-lR-ALT-HVAC) (Page 3 of 3)
Documentation Author's Declaration Statement
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Shantel Faugno
Sha.ntr,Li`augno-
Company:
Signature Date:
Esser Services, Inc.
2018-03-20
Address:
CEA/ HERS Certification Identification (if applicable):
PO Box 1636
City/State/Zip: r
Phone:
Cathedral City CA 92235 ,.j
760 324-0550
Responsible Person's Declaration statement
r
I certify the following under penalty of perjury, under the laws of the State of California: i
1. The information provided on this Certificate of Compliance is true and correct. .L --'
r
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility.for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for -approval with this building application.
permit
5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building-permit(s) issued for the building, and made available to the enforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate ofCompliance pliance is required to be nciuded with�the do uc mentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Responsible Designer Signature:
Shantel Faugno
ShantxLFa.ugno-.
Company:
Date Signed:
Esser Services, Inc.
2018-03-20
Address:
License:
PO Box 1636
489046
city/State/Zio;
Phone; -
Cathedral City CA 92235
760-324-0550
Digitally signed by CHEERS'". This digital signature is provided in order to secure the content of this registered
document, and in no way implies Registration Provider responsibility for the accuracy of the Information.
Registration Number: 418-A020016953A-000-000-0000000-0000
Registration Date/Time: 2018-03-20 08:56:02
HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2018-03-20 08:56:04
Schema Version: rev 10/16