Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2017-0005
78-495 CALLE TAMPICO 4 VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN &DEVELOPMENT DEPARTMENT FAX (760).777-7153 i BUILDING PERMIT Date: 3/1/2017 Application Number,: BSOL2017-0005 Owner: Property Address: 81335 THUNDER GULCH WY BRADSHAW APN: 767790063 81335 THUNDER GULCH Application Description: BRADSHAW / SOLAR FO P00 �q� LA QUINTA, CA 92253 'Property Zoning: ® L0/L_"�\, Application Valuation: $5,000.00 Applicant: MAR 012017 Contractor: TESERRA TESERRA P 0 Box 1280 CITY OF LA QUINTA P 0 BOX 1280 COACHELLA, CA 92236 DESIGN AND DEVELOPMENT DEPARTMENT COACHELLA, CA 92236 (760)389-9222 Llc. No.: 656128 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class- C-8 C10 C29 C53 C27 D12 o.: 656128 Date: 1 Contractor: OWNER=BUILDER DECLA N I hereby affirm under penalty of perjury that I am a pt from the Contractor's State License Law for the following reason (Sec. 7031.5, usiness and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file_ a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more.than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: STARSTONE NATIONAL INSURANCE COMPANY Policy Number: T10170317 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of Labor Code, I shall forthwith comply wit those rovisions. Dat Applicant - WARNING: WARNING: FAILURE TO SECURE WORKERS' COMPENSAWN COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PfiffALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is hot commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentione property for inspection purposes., �1 Date Signature (Applicant or Age f Y-- Date: 3/1/2017 Application Number: BSOL2017-0005 Owner: Property Address: 81335 THUNDER GULCH WY BRADSHAW APN: 767790063 81335 THUNDER 3ULCH Application Description: BRADSHAW / SOLAR FOR POOL LA QUINTA; CA 92.253 Property Zoning: Application Valuation: $5,000.00 Applicant: Contractor: TESERRA TESERRA P 0 BOX 1280 P 0 BOX 1280 COACHELLA, CA 92236 COACHELLA, CA 92236 (760)389-9222 Llc. No.: 656128 -------------------- ------------------------------------------------------------------------ Detail: ROOF MOUNTED SOLAR POOL WATER HEATING SYSTEM - 600 SF COLLECTOR, ELECTRICAL CONTROL AND PIPING TO EXISTING POOL PLUMBING. THIS PERMIT DOES NOT INCLUDE ADDITIONAL OR ALTERATION TO EXISTING POOL PUMP. 2016 CALIFORNIA BUILDING CDDES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $96.27 Total Paid for PERMIT ISSUANCE: $96.27 DESCRIPTION ACCOUNT QTY AMOUNT SOLAR THERMAL 101-0000-42401 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT SOLAR THERMAL PC 101-0000-42600. 0 $25.33 Total Paid for PLUMBING FEES: $50.66 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 Bin ># Permit # AoQW-_ Project Address: /— S 3-5 Qty of La Q C. in to Building & Safety Division 787495 Cafle Tampico La Quinta, CA 92253 - (760) 777-701,2 Building Permit Application and Tracking Sheet owner's Name: A. P. Number: Address: — Legal Description: City, ST, Zip: - ntra Co tr• co. h ne: Telephone: P Address:Project Description:��S�� City -_ST, Zip: L �a © ele hone: Telephone- p 7 State State Lic. # : City Lic. #: Arch., Engr., Designer: Address: City, ST, Zip: Telephone: OEM aneY n Type: Occupancy: Constructiontrueti P • State Lic. Project ecttYP (circle one): New Add'n Alter Repair. Demo, Name of Contact Person: Sq. Ft.: # Stories: #[nits: Telephone # of Contact Person: _a 7 Estimated Value of Project: r5 OpO� QQ APPLICANT: DO. NOT WRITE BELOW THIS LINE N Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cafes. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance. Tit!e 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready forcorrcctions/issue Electrical . Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''d Revicw, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. \Vks. Appr Date of permit issue school Fees, Total Pcrmit tees SITE LOCATION m TRUE NORTH VICINITY MAP 1 TRUE NORTH BRADSHAW RESIDENCE 81335 THUNDER GULCH WAY LA QUINTA, 92253 1 SOLAR POOL HEATING SYSTEM SCOPE OF WORK 1. THE DESIGN BUILD CONTRACTORS SHALL FURNISH AND INSTALL SWIMMING POOL SOLAR HEATING SYSTEM, INCLUDING, BUT NOT LIMITED TO: SOLAR COLLECTORS, ASSOCIATED MANIFOLDS, SOLAR COLLECTOR CONNECTION HARDWARE, SOLAR COLLECTOR MOUNTING/INSTALLATION HARDWARE, DIGITAL SOLAR CONTROL SYSTEM, AND ALL APPURTENANCES. 2. FURNISH AND INSTALL DIGITAL SOLAR CONTROLLER AC POWER AND ROOF TOP SENSOR SHALL BE LOCATED ON THE POOL EQUIPMENT BUILDING ROOF. 3. FURNISH AND INSTALL ROOF SUPPORTS AND COLLECTOR ANCHORS. 4. FURNISH AND INSTALL PIPE FASTENERS, MOUNTING HARDWARE, AND RIGID PIPE CLAMPS FOR PIPING UP THE WALL. STANDARDS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE APPLIC EDITIONS OF ALL NATIONAL, STATE, AND LOCAL CODES, LAWS, REGU AND ORDINANCES, INCLUDING THE FOLLOWING: AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) AMERICAN SOCIETY OF TESTING MATERIALS (ASTM) 2016 CALIFORNIA ELECTRICAL CODE (CEC) 2016 CALIFORNIA BUILDING, RESIDENTIAL, ELECTRICAL, PLUMBING ENERGY CODES WITH LOCAL AMENDMENTS 2016 GREEN CODE 2016 COUNTY FIRE CODE SHEETINDEX P-1 VICINITY MAP AND PROJECT LOCATION/ COVER PAGE P-2 SITE PLAN PT -1 POOL SOLAR SYSTEM FLOW DIAGRAM PT -2 POOL SOLAR ATTACHMENT DETAIL PT -3 POOL SOLAR CONTROL SPEC SHEET PT -4 POOL SOLAR COLLECTOR ,SCITY OF LA QUINTA BUILDING & SAFETY DEPT APPROVED FOR CONSTRUCTION DAT rt ! Zd I % BY DELIVERY, STORAGE, AND INSTALLATION SHALL COMPLY WITH SPECIFICATION SECTION 13563. ALL PIPING SHALL BE SCHEDULE 40 PVC -ASTM FITTINGS, SOLVENT WELDED. CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INSTALLED IN EXISTING DWELLING UNITS OR SLEEPING UNITS WITH A FOSSIL FUEL BURNING HEATER OR APPLIANCE, FIREPLACE, ATTACHED GARAGE. CARBON MONOXIDE ALARM SHALL BE LOCATED IN EACH AREA GIVING ACCESS TO A SLEEPING ROOM AND ON EACH STORY DWELLINGS WITH MORE THAN ONE STORY CARBON MONOXIDE ALARMS ARE PERMITTED TO BE SOLELY BATTERY OPERATED WHERE NO CONSTRUCTION IS TAKING PLACE. SAFETY SIGNAGE PRESENT IN COMPLIANCE WITH CA BUILD. CODE TITLE 24 S(707 �__ UNTREIC Y- mp.7 SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C-46 LIC .#859460 (949)348-9276 PROJECT POOLTHERMAU SHW SYSTEM CONSTRUCTION HOURS: 7AM-8PM, M -F; 8AM-8PM, SATURDAY; NO SUNDAY OR LEGAL HOLIDAYS.THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOLID WASTE, PETROLEUM BYPRODUCTS, SOILPARTICULATE, CONSTRUCTION WASTE MATERIALS,OR WASTEWATER GENERATED ON CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED,CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM. v" DESIGNER A. HILL COVER PAGE REVISIONS OCCUPANCY GROUP: R-2 CONSTRUCTION TYPE: V/B SHEET NO. P-1 gl - 3� 3 s-rhun1f)6P_ Cz uV-H 65-dl,,2W176Vc�- SUNTREK SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C-46 LIC. #859460 (949)348-9276 PROJECT DETAIL PAGE 1. SOLAR POOL HEATING ARRAY A 2. ROOF MOUNT/CONNECTION DETAIL A PT -2 3. WALL MOUNT/CONNECTION DETAIL B PT -2 4. POOL EQUIPMENT B PT -1 5.2" SCH. 40 PVC SUPPLY & RETURN PIPING TO POOL EQUIPMENT AREA, ASTM FITTINGS, SOLVENT WELDED SUNTREK SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C-46 LIC. #859460 (949)348-9276 PROJECT OOLTHERMAU PSHW 3 - SYSTEM GENERALNOTES U • LOCATION (9POOLl W POOL SYSTEM SIZE: 600 SQFT w o. OPTIMUM FLOW RATE: 60-90 GPM U g j DESIGN FLOW RATE: 70 GPM w Z 2 POOL H W } UI J U-) Z i W C" Q ' • Lj- W9W ` W Z J.. Z� -I Q = C1 O _ g DRIVEWAY Cl a OF LJ� QUINTA `� " g BU MING &SAFETY DEPT. 0 In PPR®VE® ' m - •' � • ' 4 • - OR CONSTRUCTION ' ' - PROPERTY LINE 5 4 � DATEj1124BY >-e- � • _ 3 DESIGNER a Z8G@ vi�i��Yeide HILL 1. OCCUPANCY GROUP: R-2 SITE PLAN y NUMBER OF STORIES A STORY ROOF PLAN SOLAR PANELS LOCATED ON CONCRETE STILE ROOF REVISIONS - 2. COMPLY WITH ALL MANUFACTURERS LISTINGS AND PLAN - POOL THERMAL SOLAR SYSTEM 'NSTALL2016NINRNATIO AL ; 2016 INTERNATIONAL BUILDING CODE - 2016 NATIONAL ELECTRICAL CODE SHEET NO, 2016 INTERNATIONAL ENERGY CONSERVATION CODE P-2.2 ' 20161CC/ANSI r NOTES: A c '® 1O CONTROL WIRING CONNECTS TO LINE SUS SIDE OF EXISTING.POOL PUMP TIME PT -4 rw.s",".s—Va—p—y CLOCK. 120V/240VAC SOLAR COLLECTOR (N) SUNTREK INDUSTRIES VACUUM RELIEF & MANIFOLD ON 5 HOLLAND #215 2O ALL ROOF PIPING SHALL BE BLACK SCH. 40 PVC VALVE (TYP) ROOF IRVINE, CA 92618 ASTM FITTINGS, SOLVENT WELDED C-46 LIC. #859460 (949) 348-9276 . SOLAR O TEMPERATURE PRodECT ALL PIPING -FROM EQUIPMENT TO ROOF SHALL BE SCH 40 PVC SENSOR —�- —�► ASTM FITTINGS, SOLVENT WELDED POOLTHERMAU B TS SHW SYSTEM O4 N=NEW PT -3 E=EXISTING LOCATION (N)SOLAR DIGITAL CONTROLPANEL 12V� w POOL 1 . 120V/240V POOL SYSTEM SIZE: 600 SQFT z LU OPTIMUM FLOW RATE: 60-90 GPM _ _ DESIGN FLOW RATE: 70 GPM _ �� W Q } w CITY OF LA QUINTP1 I N)2.5"PVC �/ �¢ W . BUILDING & SAFETY DEPT. 12� E Q = v o A���OVEI� 12� f 2 �gIL FOR CONSTRUCTION CHECK 0 °° O DATE 31 /�� Y I -(N)CHECK` VALVE(N) 9 As—� —VALVE — — I"-- m a. 3 -WAY !% POOL (N)ACTUATOR POOL FILTER GAS DESIGNER : 2" PVC � I (E) - (E) 2" PVC HEATER a HILL i (E)VS CIRCULATION SYSTEM FLOW POOL PUMP u DIAGRAM NOTE: REVISIONS FROM POOL ALL PIPING SHALL BE 2" SCH. 40 PVC TO POOL B POOL - SOLAR COLLECTOR FLOW / INSTALLATION DIAGRAM SHEET NO, PT -1 CLAMP 2' SCH. 40 PVC SUPPLY 8 RETURN PIPING TO POOL— EQUIPMENT AERA ASTM FITTINGS, SOLVENT WELDED 1/4' DIA x 2• f LAG SCREW CEMENT WALL PLASTY ANCHOR SOLAR Q0LLEQT0RBfl2Mg 0 U! N WALL MOUNT BUILDING & SAFETY DE FOR CONSTRUCTION DATE 3/112*17BY"�C— TITEBONDOALLW EATHER DESIGNER A HILL co EDTOR SUEK . WNIFCM SEE Y�So�— PHYSICAL DETML'A', SM. Phi ' EUSTdAER DEF -1. SM. PTJ INDIA. aS LAOSCREW FAe,aCamD sniAP (r W. AT EApIMMOFOID) WATER TUBaaO, SEE EPDN ELASTOMER 1N' x 13S STADIIES9 W ' IRVINE, CA 92618 APPLICATION Pl/3TICANGIOR fANCRETE OR CIAYTDE C46 LIC. #859460 (949) 348-9276 GUIDELINES Method of application:Cartridge%ulkin gun RDOF ADNESNE Coverage (maximum): Approximate length of bead according to bead diameter. PROJECT PTG`-2 Container 1/8" bead 1/4" bead 3/8" bead SOLAR COLLECTOR MOUNTING DETAIL . ROOF MOUNT SHW SYSTEM CLAMP 2' SCH. 40 PVC SUPPLY 8 RETURN PIPING TO POOL— EQUIPMENT AERA ASTM FITTINGS, SOLVENT WELDED 1/4' DIA x 2• f LAG SCREW CEMENT WALL PLASTY ANCHOR SOLAR Q0LLEQT0RBfl2Mg 0 U! N WALL MOUNT BUILDING & SAFETY DE FOR CONSTRUCTION DATE 3/112*17BY"�C— TITEBONDOALLW EATHER DESIGNER A HILL SUNTREK BOND ROOFING SEALANT SUEK REVISIONS �>� 0D�4I-9 °' Franklin International TECH SERVICE 1 -80D -347 -GLUE www.titebond.com CM Franklin International. All rights Y�So�— PHYSICAL Type: Synthet c elastomeric polymer Calculated VOC (less water): 389 g/L SUNTREK INDUSTRIES 5 HOLLAND #215 Weir�!I'Igallon:9.ellbs. State: Lig tan PROPERTIES Color. L ght tan Flashpolnh Less than OeP. PT -2 Solids: 6 Freeze/thaw stability: Will not freeze Viscosity: 130,000 cps Storage life: 12 months in tightly dosed containers at 75°F. IRVINE, CA 92618 APPLICATION Application temperature:0•F. to 100•F. Service temperatures: -20eF. to 120•F. C46 LIC. #859460 (949) 348-9276 GUIDELINES Method of application:Cartridge%ulkin gun Coverage (maximum): Approximate length of bead according to bead diameter. PROJECT Container 1/8" bead 1/4" bead 3/8" bead POOL THERMAU . OZ. Cartridge1294h. 29 oz Cartridge 355 ft. 89 N. 39 H. SHW SYSTEM Working lime: Approximately 1420 minutes fora 1/4" bead Working surfaces: Surfaces to be bonded should be dean and free from excessive oil, grease, water, dirt or any other material that may deter adhesion. Apply adhesive to each piece of furring, studs or LOCATION Floor joists to be covered. When bonding subfloors or wet frozen and treated lumber, nail orsctew each sheet as recommended by the American Plywood AssodaHon. Cleanup: Scrape off dried excess with a putty knife. Remove residue with mineral spirits or equivalent solvent Follow solvent vendor's when solvents. NOTE: Test solvent W precautions using . on an outof-the-way area to make sure it will not mar or attack the surface. v PRODUCT Works extremely well in colder temperatures Ideal for OSB, and wet frozen and ACA & CCA treated lumber W FEATURES plywood, particleboard, Fills gaps and irregularities between materials to provide a more solid backup surface .} V) • Exceeds the performance requirements of the American Plywood Assodation AFG-01 Specification, ASTM D3498, ASTM 0557, CAN/CCSB-71.26M CAN/CGSB-71.25M Q } and - = C7 U Titebond All Weather Subfloor Adhesive is not designed for continuous submersion or for use on LI MI TATIONS ppolystyrene foams. Foryolystyrene foam, tub surrounds and most other we recommend plastics, Titebondlnterior/Extenor Construction Adhesive." N Z W =-J) rn � CAUTION DANGER: EXTREMELY FLAMMABLE VAPOR HARMFUL Contains hexane and toluene. Keep away from heat sparks and flame. Use only with positive cross -ventilation Avoid breathing vapors. Q STATEMENT Do not swallow. Do not allow eye contact or prolonged skin contact Uncured product can Ouse eye or s+ W F W = skin rritatiort Prolonged or repeated overexposure to solvents in uncured product tan cause k�ktral nervous system, peripheral nervous system, eye, skin, Bver, kidney or respirarory system effects. FIRST ` Z AID: If dizziness or other adverse effects are experienced, move to fresh au; a6 physidan if discomfort persists. If eye contact acors, Hush eyes with water for 15 minutes; contact physidan immediately If S Z J = O Q swallowed, do not induce vomiting; contact physidan immediately. Wash skm contact areas with sop g and water, contact physidan if imtation persists. For additional udormatioTl, refer to Material Safety to D_ Data Sheet KEEP OUT OF THE REACH OF CHILDREN. M WARNING: This product contains toluene, a chemical known to the State of California to cause birth Q defects or other reproductive harm. Q _] 0 9 ORDERING Units Packages I N FOR MOTION Cat. No. Size per Package Weight per Pallet 45492 29 oz Mini Pallet 144 tubes 352 12 5491 1OS oz Cartridge 12 11 108 m 5492 29 oz Cartridge 12 30 38 DESIGNER A HILL ATTACHMENT DETAIL I:po antNotimOurmam,meraatlmm,umYimthe use of this pwd rlambasedantr,r,tell—dmDerlabla.nth.—fDwF�mbbeyondft mtrad i th,_r a.6 ren guarantee.,--ty, -p—,d m bnpaed, b made u to an—.& ,lddmel to wd,u tamelimg or pao:mon or ue rmin W be untamed O thu i, ec rda ,ith ft direcd a mdaimM w w be 7be ma Tufa nim o pr,,* di claim re poaromtythemf m Dunne of rwthE g=a it d herein shall be—ea u a recommendation m ure any produn In mN11D with misting lawn ardor patrnb wwring any malarial w use REVISIONS �>� 0D�4I-9 °' Franklin International TECH SERVICE 1 -80D -347 -GLUE www.titebond.com CM Franklin International. All rights SHEET NO. . © ADHESIVE SPEC PT -2 Solar Collectors ullding. elght Additional Notes: 1. Solar Collectors lay flat on roof, NOT TO EXCEED 3" HIGHT FROM ROOF SURFACE OR RACKING 2. Solar Collectors will not exceed maximum building height 3. Solar Energy appurtenances shall be screened to the maximum extent possible without compromising the effectiveness of the solar collectors and shall be painted a color similar to the color of the surface upon whil they are mounted.. 4. All PVC piping exposed to sunlight shall be protected from LIV radiation. 5. A time switch or similar control mechanism shall be installed (existing) as apart of the pool water circulation control system that will allow the pump to be set or programmed to run only during off-peak electric demand period, and for the minimum time necessary to maintain the water condition required by applicable. Public health standards. Sec.114(b)3ii, 2008 Building Efficiency Standards. CITY OF LA QUIN A BUILDING &.S APPROVED T ePOOL SOLAR QOLLkTC6CN20QN LDATE=-3//47J=/:Ty SolarTouch Control Panel 'Soler Touch - Water 60F Target Temp 80F -0000M 3 4 5 status wnu cos rme a a. OPERATION Mm,u: Press to - menu end smoo mmugh option.. l.eee/Atore: Press snows to tmrryoratura m r.4o Move areor upldwm to Bdlust setWp d n dot wlWn memre. Eater: Prow to seloci a mew Item. Saud a setting. Dlsebb and RaEnWe Solaerbuch system: Press end hold Enter for Uvea seconds. roaamus. "awmG - .e.,w.er: avec. es,w xcxwvecs: m�,m mwNeam. uumLaowC,asmrR rswP vtaraurcartrcranhrt . (D Liquid Crystal Display (LCD): The system LCD displays backlighting for easy viewing of the menu items and status messages. Each button press will light the display. When an event message is displayed, the backlight will also be on. Q System Status LED Indicator: When indicator is green, the system is running normally. If indicator is red an error occurred. See page 10 for error conditions. 0 Menu Button: Access Main Menu and exit menus. Press and hold this button to access the Advanced Menu. Scroll through menu options. While in a menu or sub - menu, access a previous menu level or item. If no menu activity is detected after 30 seconds, the main screen is displayed. All menu settings are permanently saved and retained even after the unit is power off. ® Less / More buttons: Lower or Raise target water temperature. Move cursor Up/Down to adjust menu setting within menus. Q Enter button: Select a menu item and save a menu setting. Press this button to view Solar water set point temperature setting. The display will automatically revert back to the monitoring water and solar temperatures after 30 seconds from the last selection. Note: Press and hold the Enter button to disable He Cooling and Freeze Protect (display shows "SolarTouch Disabled'). Press and hold the Enter button again to enable SolarTouch. e. SOLAR CONTROL $r—" to *) . UNTREK Yam Sular 6a� Compsvy SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C46 LIC. #859460 (949)348-9276 PROJECT POOLTHERMAU SHW SYSTEM LOCATION W LU U LU Z W} >- U) In x r, 0 W DC. Q x-�e W u' Z = J Q =° 0 2 o L0 EL _M � 0 U) m� DESIGNER A. HILL PT CONTROLLER SPEC SHEET SHEET NO, PT -3 SRCCSearch Collector Record Detail httpsJ/securedb.fsee.ucf.edu/srcr/coll_detail?srx_Id=2005004A I SOLAR COLLECTOR CERTIFIED SOLAR COLLECTOR CERTIFICATION AND RATING gOLgR SUPPLIER: Sunteek Industries, Inc - 5 Holland, Building 215' 5 RCC Irvine, CA 92618 USA MODEL: �•�• COLLECTOR TYPE: SunTrek Unglazed Flat -Plate SRCC OG -100 CERTIFICATIONM 2005004.8 ALL SUESOF THIS rAUSTOR WD9.ARE OERnFED COLLECTOR THERMAL PERFORMANCE RATING Megaloales Per Sgaare Meter Per Day Tbooraodr or BTU Per Sgaare Fact Per Dy CATEGORY CLEAR MILDLY CLOUDY CATEGORY CLEAR MILDLY CLOUDY (Till) DAY CLOUDY DAY (71-7b) DAY CLOUDY DAY A (-5•C) 19.7 '15.7 11.8 A (-9 'F) 1.7 1.4 1.0 e (5 •C) 12.7 8.9 5.1 B (9 •F) 1.1 0.8 0.4 C (20•C) 5.5 21 0.0 C (36•F) OS 0.2 0.0 D (50 °C) 0.0 0.0 0.0 D (90 M 0.0 0.0 0 E (80•c) 0.0 0.0 0.0 E (144 7) 0.0 0.0 0.0 A- Pwl Hntivg (Went Cimne) It. Pool Hinting (Cool Ciitmk) c. Waw Heating (Warm Climate) D. Waw Hmtivg (Cool Climete) & A"Ic-diti-ins Original Certification Date: 10 JUN b5 COLLECTOR SPECIFICATIONS G-Area:3.869m k 41.6111 Nel Apentom Ana: 3.87 ml 41.64 R2 Dry Weight: 211 kg 47. Ib Flab Capacity: 8.7 liter 2.3 sol Teri Prenares 414. KP. 60. psis COLLECTOR MATERIALS Pressure Drop ' Fri..: Now Fl- AP 'Cavcr(Ootm): None mVa Cpm h b 1120 Coverpwer): None • lube. EPDM I Abrorbar Mater W: Iaraladoo Side: None Plate -Nora - Ab-berC dag: Nape lambOoa Berk: Nave TECHNICAL INFORMATION EDkknry Eq-tim (NOTE: Beed oa gran aro and (P)IM1T41 Y INTERCErr SLOPE S 1 UNITS: g-0.856 -1793390 (Pyl 0.03856 (WA 0.860 -17.678 W/m2.°C 1 PUNITS: g. 0.056 1.15906 (Pyl. 0.00377 (P)24 0.860 .3.114 Btamrn2.-F Inddenl Angle Modiner l(S)-11ear0. 1, 0.40-60°1 Model Tkstcd: SwThk Kea -1 -0.083(5) o.Ost(Sf` Ten fluid: Waw Kra - 1 -0.03 (S) Linear Fit TM Flan Rite: 70.1 int /a.m2 0.1032 sptalR2 REMARKS: i u, wmlucwt_Wwn. O SCALE Technical Specifications for Suntrek Solar Pool Collectors SUNTREK Collector.Extruded Ethylene Propylene Diene Monomer (EPDM) elastomer extrusion Ya Water channel: ID = .190; OD = .333' Weight 1 Ib. per square foot dry, 1.5 Ib. per square foot wet Manifold: Polypropylene, 2 -in diameter, 72 channels Maximum operating temperature:. 160° Maximum operating pressure:40 psi BTU rating: 1024 sgft/day Optimum Flow rate:l gpm per 0.1 sgft 1 sq. foot Volumetric capacity= .053 +/- 2% US Gallons (.201 +/- 2% Liters) Made in the USA USPatent#: Des. 420,420 Head Loss:.008'persgft @ .1gpm per sgft 190' 6.0 .333' EPDM Elastomer Water Channels 28- .� 24' ....................................................................................................... ..............................................................................L9S. ' T-237s- ............................................................................ 0.................................................................................... One Piece Polypropylene Manifold NSF -50 Approved 2 Engineered for maximum performance, Suntrek solar pool heaters are designed unique continuous turbulent flow water channels. this innovative design improves the transformation of solar energy into thermal energy for heating your pool water. The material used for the Suntrek thermal heater is.EPDM elastomer, which under normal operating conditions will have a useful life of more than 20 years. The Suntrek heater becomes virtually a permanent part of your pool and adds considerable value to your home or business. Corporate Headquarters: 5 Holland #215 Irvine, CA 92618 (949) 348-9276 Fax (949) 348-1626 ww W.SUrItrd VS618 P.e6M CITY OF LA QUINTA ILBUILDING & SAFE/TY DEPT. APPROVED FOR CONSTRUCTION DATE 3/1 /14I113Y $1� UyaNT . ,roar So1v Soergy �nF�r SUNTREK INDUSTRIES 5 HOLLAND #215 IRVINE, CA 92618 C-46 LIC. #859460 (949)348-9276 PROJECT POOLTHERMAU SHW SYSTEM LOCATION W U W Z =M �N Z W5- H WF W WZ = J Q=a O =~g a Cl) O y� In mr DESIGNER A HILL PT COLLECTOR SPEC SHEETS SHEET NO. PT -4 -