BELC2017-009578-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PermiitType/Subtype: ELECTRICAL/ c&iy/ 4 ZP Qum& DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BELC2017-0095 Property Address: 78660 AVENIDA TORRES APN: 770171008 Application Description: MOONEY RESIDENCE / ELECTRICAL UPGRADES Property Zoning:, Application Valuation: $600.00 Applicant: D n a J M K ELECTRIC �1 42225•EVEREST DR' INDIO, CA 92203 NOV 0 3 2017 COMMUNITY CITY OF MC�L`IN MENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C10 License No.: 962833 D'ate:ai //'P /// ' Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant fora permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_J 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not in or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (� I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX. (760) 777-7011 INSPECTIONS (760) 777-7153 Date:. 11/3/2017 Owner: GAIL MOONEY 78660 AVENID_a TORRES LA QUINTA, CR 92253 Contractor' J M K ELECTRIC 42225 EVEREST DR INDIO, CA 9220 (760)218-1172 Llc. No.: 962833 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one c1the following declarations: I have and will maintain a certificat= of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the. or which this permit is issued. ave and will maintain workers' c.mpensation insurance, as required by Se _of the Labor Code, for the perfornance of the work for which this permit is i sued.. My workers' compensation insurance carrier and policy number are: Carrier: EXEMPT Polity Number: _ I certify that in the performance of -he work for which this permit is issued, 1 shall not employ any person in any manner soes to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers" compensation provisions of Section =700 of the Labor Code, I shall forthwith comply with those provisions. Da1/ -3 17 Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOF; IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNCINLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is perform:ad under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City df La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation, I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representat ves of this city'to enter upon the above- mentioned property for inspection purposes. Date) 11-3 47 Signatu�e.(Applicant of Agent): r i - Date: 11/3/2017 Application. Number: BELC2017-0095 Owner: Property Address:` J": ' ^78660 AC/ENIDA TORRES GAIL MOONEY APN: '770171008 78660 AVENIDA TORRES Application Description: MOONEY RESIDENCE / ELECTRICAL UPGRADES LA QUINTA, U. 92253 Property Zoning: Application Valuation: $600.00 Applicant: Contractor: J M K ELECTRIC J M K ELECTRIC' 42225 EVEREST DR 42225 EVERESs DR INDI0, CA 92203 INDIO, CA 92203 (760)218-1172 Llc. No.:, 962833 Detail: ELEC. WHOLE HOUSE UPDATE SWITCHES, OUTLETS AND LIGHTNG PER 2016 CEC DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $26.01 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $26.01 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES/FIXTURES, ADDITIONAL 101-0000-42403 0 $156.00 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES/FIXTURES, ADDITIONAL PC 101-0000-42600 0 $39.00 Total Paid for ELECTRICAL: $247.02 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $98.83 Total Paid for PERMIT ISSUANCE: $98.83 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA'92253 (760) 777-7125 FAX (760) 777-7011 RESIDENTIAL PLAN.CHECK CORRECTION LIST (os) DATE: 10/20/17 STATUS: FIRST REVIEW PLAN CHECKED BY: JJOHNSON TELEPHONE NUMBER: 760- 777-7130 ADDRESS: 78-660 AVENIDA TORRES DESCRIPTION: ELEC. UP DATE APPLICANT: MOONEY PLAN CHECK #: BELC2017-0095 This submittal has been checked for compliance with the 2016 California Residential, Mechanical, Electrical, Plumbing, Green Building and Energy Codes, and the City of La Quinta Municipal Code. I APPLICANT: The following items are being returned to you for correction: 3 SETS OF PLANS THIS CORRECTION LIST BUILDING DEPARTMENT STAFF: DO NOT accept any resubmittal unless ALL of the following items are included: ,REDLINED SETS 1 P/C, 2 NEW REVISED SETS r/ THIS CORRETION LIST W/ PESPONSES INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specificclly where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with 'a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect- or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section 5536. Resubmittals will not be accepted with s gnatures missing. 5) Return this list, your written responses, and all documents listed above with your resu:)mittal. Residential Plan Check Correction List Page 1 of 5 SECTIO A - GENERAL ' 1 ote on Pla _ _ ns: ;All constructionahall comply.witli the 2016 California,Resid'"� � entiai�Mechanical,lElectrical, Plumbing, Green Building and �E. nergy Codes and'the'L'd'QuintaMunicipal;Codo:" Remove notes referencing . other Codes. SECTION E = ELECTRICAL ,. 1) elephone jacks are required in all habitable rooms except a Dining area which is immediately adjacent to a Kit -en or iving Room. (LQMC §8.03.050) Show all telephone jack locations on Plan. 2) ab elevision outlets are required in all habitable rooms except Kitchens_ and Coining area: (LQMC § .03.050) Show all television jack locations on Plan. A _. ote o ons: "Aluminum conductors are permitted only if size 1/0 or larger, and only to feed main or sub- pa s. All other current carrying conductors shall be copper." (LQMC §8.03.040) - � ' I , 4 Note on Plans: Provide. ofleast.two 20-ampere small:appliance'branch circuits t�� ser- all.wall,.floor, and countertop receptacles in:kitchen; pantry,.t akfast room, dining,room,_or_similar area.,S_u_ch circuits shgll� i have no,other.outlets."`(CEC-§210.11(C)(1) and 210.52(8)(1) through 210.52(B)(3); 5) ote on Plans: `LProvide afleast one 20-ampere branch-circuit,to`serve areas desgnated for the installation ✓ of lav _�ry equipment`Such circuits) shall_ha_ve no-.other outl_ets." (CEC §210.11(C1(2); 210.52(F)) R ote on Plans: "Provide at least one-120-volt,20-ajnpere branch circuit to serve L;atFiroom�rec�eptacles. Such-u` (-s) shalChave no otheroutlets:"`(CEC §210.11(C)(3);-210:52(D))cr 7) Provieat r least one wall receptacle outlet within thirty-six '(36) inches of the outs de edge 'of each . ba room basin. The receptacle outlet shall be located on a wall or partition that s adjacent to the basin or .t asin countertop, located on the counter top, or installed on the side or face of the'basin cabinet. In no case shall the receptacle be located more than twelve (12) inches below the top of the basin. (CEC §210.52(D)) 8) pecify GFCI protection for receptacles in bathrooms. (CEC §210.8(A)(1)) 9 ecify GFCI protection for receptacles in garage. (CEC §210.8(A)(2)) 10ecify GFCI protection for outdoor receptacles. (CEC §210.8(A)(3)) , 1 peci protection for receptacles serving the kitchen countertop. (CEC §210,8(A)(6)) 1 Specify GFCI protection for receptacles serving laundry, utility, and wet bar sinks where the receptacle is located wi 6 feet of the outside edge the sink. (CEC §210.8(A)(7)) 13 pecify GT-protection at receptacles located within six (6) feet of the outside edge of a bathtub or shower stall. §210.8(A)(9)) , Speci FCI protection for receptacles serving laundry areas. (CEC §210.8(A)(10)), ; 1 Specify GFCI protection for branch circuit outlets that supply dishwashers. (CEC §210.8(D)) 16�devilces te on Electrical Plan: "A1L120-volt, single;phase, 15 and'20=ampere,branch circuits supplying out or ✓ installed'in�,dwelliog unit kitchens, family rooms, dining ooms, living room ,.parlors, libraries, dens, I �bedrooms,,sunrooms, recreation,rooms; tlosets,(hallways laundry areas or similar rooms or areas shall be protected.by an listed arc-fault circuit interrupter, combination type; installedto provide;protectiori of they branch circuit or by any of the other ^means described in 210.12(A)(2) through (6).""(CEC§210.12(A)) Residential Plan Check Correction List Page 2 of 5' L Informational item: Please note that this requirement requires protection of the ent re branch circuit supplying outlets (luminaires, fans, smoke alarms, etc.) and the devices within dwelling unit. Note on ectrical Plan: "Modified, replaced, or extended 120 -volt, single phase, 15- and 20 -ampere /raircuits supplying outlets or devices installed in dwelling unit kitchens, family rooms, dining rooms, oms, parlors, libraries, dens; bedrooms, sunrooms, recreation rooms, closets, hallways, laundry similar rooms or areas shall be protected by either a listed combination4ype AFCI located at the the branch circuit or a listed outlet branch -circuit type AFCI located at the first receptacle outlet of eexsting branch circuit." (CEC §210.12(B)) 18) . then, pantries, breakfast rooms, dining rooms, and similar area receptacles scall comply with the �Pr ing: (CEC §210.52(C)): A e a receptacle outlet at each wall counter space 12 inches or wider. ��� b) rovide receptacle outlets at each wall counter so that no point along the wail line is more than 24 inches, measured horizontally from a receptacle outlet in that space. c) Provide at least one receptacle outlet at each island counter space with a long dimension of 24 inches r grea and a short dimension of 12 inches or greater. Prov' a at least one receptacle outlet at each peninsular counter space with a long dimension of 24" or ater and a short dimension of 12" or greater. A peninsular countertop is measured from the connecting edge. Informational item: eceptacle outlets shall be installed not more than 20 inches above the countertop. Receptacle out rendered not readily accessible by appliances fastened in place or appliances occupying dedicated ce shall not be considered as these required outlets. 19) rovide at l t one receptacle outlet in areas designated for the installation of laundry equipment. (CEC §210.1 (2) & 0.52(F)) 20) rovide east one receptacle outlet in each car space located within an attached garage. (CEC §210 (G)(1)) at least one receptacle outlet in hallway 10 feet or more in length. (CEC §?10.52(H)) 'Provide in every kitchen, family room, dining room, living room, parlor, library, den, sun room, bedroom, recreation room, or similar room or area of dwelling units, receptacle outlets so that no point along the floor line in any wall space is more than 6 feet, measured horizontally, from an outlet in that space, including any wall space 2 feet or more in width and the wall space occupied by fixed panels in exterior %y,affs, but excluding sliding panels in exterior walls. The wall space afforded by fixed room dividers, such as freestanding bar -type counters or railings, shall be included in the 6 -foot measurement. (CEC §210.52(A)) See Plan for locations not meeting this requirement. Informational item: As used in this section, a "wall space" shall be considered a wall unbroken along the floor line by doorways, fireplaces, fixed cabinets and similar openings. Each wall space 2 feet or more in width shall be trspted individually and separately from other wall spaces within the room. A wall :pace shall be permitted to i Jude two or more walls of a room (around corners) where unbroken at the floor line. Receptacle outlets sh5dl, insofar s practicable, be spaced equal distances apart. Receptacle outlets in floors shall not be counted as part of a required number of receptacle outlets unless located within 18 inches of the wall. The receptacle outlets insofar by this section shall be in addition to any receptacle that is part of any lighting fixture or ap,l' nce, located within cabinets or cupboards, or located over 5-1/2 feet above the f.00r. 23) P�.iways, a at least one wall switch -controlled lighting outlet in every habitable room; in bathrooms, hallways, st attached garages, and detached garages with electric power; and at the exterior side of outdoor nrances or exits. (CEC §210.70(A)) See Plan for locations not in compliance. Residential Plan Check Correction List Page 3 of 5 °� .�t auLcfa 24) Provide at least one lighting outlet controlled by a light switch located at the point of entry to the attic, underfloor space, utility room, and basement where these spaces are used for storage or contain equipment requiring servicing. The lighting outlet shall be provided at or near the equipment requiring - servicing. (CEC §210.70(A)(3)) See Plan for locations not in compliance. 25) Specify a weather -resistant type receptacle at all 15- and 20 -ampere, 125- and 250 -volt receptacles where located in damp or wet locations. (CEC §406.9(A) & (B)) 26) Specify a tamper-resistant type receptacle in all 125 -volt, 15- and 20 -ampere re:eptacles located in areas required by 210.52 and located within 5-'/2 feet of the floor. (CEC §406.12(A)) 27) Show on Plans how luminaires (light fixtures) in clothes closets conform to the following: (CEC §410.16(C)) a) Twelve (12) inches - Surface -mounted incandescent of LED luminaires with a completely enclosed light source installed on the wall above the door or on the ceiling. b) Six (6) inches - Surface -mounted fluorescent luminaires installed on the wall above the door or on the ceiling. c) Six (6) inches - Recessed incandescent or LED luminaires with a completely enclosed light source installed in the wall or the ceiling. d) Six (6) inches - Recessed fluorescent luminaires installed in the wall or the ceiling. e) Surface -mounted fluorescent or LED luminaires shall be permitted to be instclled within the closet storage space where identified for this use. 28) Note on Plans: "Luminaires (light fixtures) in tub_o_r shower,enclosures-shall-be lcbeled'suitable _for damp___; location':" (CEC §410.10(D)) 29) No parts of cord -connected luminaires, chain-, cable-, or cord -suspended luminaires, lighting track, pendants, or ceiling -suspended fans shall be located within three (3) feet horizon=ally and eight (8) feet vertically from the top of the bathtub rim or shower stall threshold. (CEC §410.100) SECTION G - ENERGY EFFICIENCY 1) All luminaires shall be high efficacy in accordance with Table 150.0-A: Specify in lighting schedule for each luminaire, the luminaire and lamp types, wattage and whether light source requires certification with Reference Joint Appendix JAB, such as required for all screw -base luminaires and recessed down lighting. (CEC §150.0(k)1A) See electrical plan for areas not in compliance. 2) All down light luminaires recessed in ceilings (not just those in insulated ceilings) -rust meet the following requirements: (CEC §150.0(k)1C) a) Shall contain light sources that are certified JAB compliant that are not of the -screw -based type; and b) Those that are enclosed, such as those often used in showers, must utilize a J48 -E compliant lamp rated for use at elevated temperatures; and c) Be listed for zero -clearance insulation contact (IC Rated) by a nationally recognized testing lab that are certified airtight per ASTM E283-04 (air leakage less than 2.0 CFM at 75 Pascals); and d) Have a gasket or caulked sealing between the luminaire housing and ceiling; and e) Allow readily accessible ballasts for maintenance or replacement without needing to cut holes in the ceilings. 3) Lighting shall be switched separately from exhaust fans and when provided under cabinets from other lighting systems. (CEC §150.0(k)2B & L) 4) In bathrooms, garages, laundry rooms, and utility.rooms, at least one luminaire must be controlled by a vacancy sensor. (CEC §150.0(k)2J) See electrical plan for areas not in compliance. 5) All interior luminaires required to have light sources compliant with Joint Appendix JA8 must be controlled by either a dimmer or vacancy sensor, except those located in closets less than X square feet or hallways. Residential Plan Check Correction List Page 4 of 5 fe, '(CEC §150.0(k)2K) See electrical plan for areas not in compliance. 6) Outdoor lighting permanently mounted to the building must be controlled by, one of the following combinations and a manual ON/OFF switch that does not override the chosen combination: (CEC §150.0(k)3) a) Photocell and motion sensor b) Photo control and automatic time switch c) Astronomical time clock d) EMCS with features of an astronomical time clock that does not allow the luminaire to be always ON, and is programmed to automatically turn lighting OFF during daylight hours. SECTION K - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. 0 Residential Plan Check Correction List Page 5 of 5 Bin# City of La Quinta Building & Safety Division mm 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet. Permit# JAI Project Address: �D �✓�� Owner's Name: A.P. Number Address: 7 LC /d✓ .� u /c /1/-o Legal Description: City, ST, Zip: cZ.s'3 Coritractor: ./ Telephone: //' / / W 7� - !/ Address: ` ' Project Description: City, ST, Zip: �� ` ?� J Telephone: -//7,2- State Lic. #:G�► G� G City Lie #: v S5 1r Arch, Engr., Designer: Address: City, ST, Zip: Telephone: MNMKM Construction Type: Occupancy: State Lic. #: Proj. Type New Add'n Alte- Repair Demo Name of Contact: t - /� SgFt: #Stories # Units: Telephone of Contact:•laD7/W Estimated Value of Project: GGG�. Cp APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check Submitted Item Amount Structural Calcs Reviewed, ready for corrections Plan Check Deposit: Truss Calcs Called Contact Person Plan CIwck Balance: Title 24 Calcs Plans Picked Up Construction: Flood Plain Plan Plans Resubmitted Mecharical: Grading Plan 2nd Rev, Ready for corrections / Electrical: Subcontractor List Called Contact Person Plumbicg: Grant Deed Plans Picked Up S.M.I. HOA Approval Plans Resubmitted Gradin€ IN-HOUSE 3rd Rev, Ready for corrections / Developer Impact Fee Planning Approval Called Contact Person A.I.P.P_ Pub. Wks. Apps Date of permit issue School Fees / Total Pcrmit Fees N DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 (760) 777-7125 FAX (760) 777-7011 RESIDENTIAL PLAN CHECK CORRECTION LIST (os) DATE: 10/20/17 STATUS: FIRST REVIEW PLAN CHECKED BY: JJOHNSON TELEPHONE NUMBER: 760- 777-7130 ADDRESS: 78-660 AVENIDA TORRES DESCRIPTION: ELEC. UP DATE APPLICANT: MOONEY PLAN CHECK #: BELC2017-0095 This submittal has been checked for compliance with the 2016 California Residential, Mechanical, Electrical, Plumbing, Green Building and Energy Codes, and the City of La Quints Municipal Code. APPLICANT: The following items are being returned to you for correction: 3 SETS OF PLANS THIS CORRECTION LIST BUILDING DEPARTMENT STAFF: DO NOT accept any resubmittal unless ALL of the following items are included: REDLINED SETS 1 P/C, 2 NEW REVISED SETS THIS CORRETION LIST W/ RESPONSES INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specificolly where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per C BC Section 1003," are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's nar-e and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section 5536. Resubmittals will not be accepted with Signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List Page 1 of 5 SECTION A - GENERAL 1) Note on Plans: "All construction shall comply with the 2016 California Residenticl, Mechanical, Electrical, Plumbing, Green Building and Energy Codes and the La Quinta Municipal Code." Remove notes referencing other Codes. SECTION E — ELECTRICAL 1) Telephone jacks are required in all habitable rooms except a Dining area which is immediately adjacent to a Kitchen or Living Room. (LQMC §8.03.050) Show all telephone jack locations on R.an. 2) Cable Television outlets are required in all habitable rooms except Kitchens and Dining area. (LQMC §8.03.050) Show all television jack locations on Plan. 3) Note on Plans: "Aluminum conductors are permitted only if size 1/0 or larger, and only to feed main or sub - panels. All other current carrying conductors shall be copper." (LQMC §8.03.040) 4) Note on Plans: "Provide at least two 20 -ampere small appliance branch circuits io serve all wall, floor, and countertop receptacles in kitchen, pantry, breakfast room, dining room, or similar area. Such circuits shall have no other outlets." (CEC §210.11(C)(1) and 210.52(B)(1) through 210.52(B)(3;) 5) Note on Plans: "Provide at least one 20 -ampere branch circuit to serve areas deEignated for the installation of laundry equipment. Such circuit(s) shall have no other outlets." (CEC §210.11(C)(2); 210.52(F)) 6) Note on Plans: "Provide at least one 120 -volt, 20 -ampere branch circuit to serve (bathroom receptacles. Such circuit(s) shall have no other outlets." (CEC §210.11(C)(3); 210.52(D)) 7) Provide at least one wall receptacle outlet within thirty-six (36) inches of the out3ide edge of each bathroom basin. The receptacle outlet shall be located on a wall or partition that is adjacent to the basin or. basin countertop, located on the countertop, or installed on the side or face of the basin cabinet. In no case shall the receptacle be located more than twelve (12) inches below the top of the basin. (CEC §210.52(D)) 8) Specify GFCI protection for receptacles in bathrooms. (CEC §210.8(A)(1)) 9) Specify GFCI protection for receptacles in garage. (CEC §210.8(A)(2)) 10) Specify GFCI protection for outdoor receptacles. (CEC §210.8(A)(3)) 11) Specify GFCI protection for receptacles serving the kitchen countertop. (CEC §211).8(A)(6)) 12) Specify GFCI protection for receptacles serving laundry, utility, and wet bar sinks where the receptacle is located within 6 feet of the outside edge the sink. (CEC §210.8(A)(7)) 13) Specify GFCI protection at receptacles located within six (6) feet of the outside edge of a bathtub or shower stall. (CEC §210.8(A)(9)) 14) Specify GFCI protection for receptacles serving laundry areas. (CEC §210.8(A)(10.) 15) Specify GFCI protection for branch circuit outlets that supply dishwashers. (CEC §210.8(D)) 16) Note on Electrical Plan: "All 120 -volt, single phase, 15- and 20 -ampere branch circuits supplying outlets or devices installed in dwelling unit kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms,-recreation rooms, closets, hallways, laundry areas or similar rooms or areas shall be protected by an listed arc -fault circuit interrupter, combination type, installed to provide protection of the branch circuit or by any of the other means described in 210.12(A)(2).through (6X" (CEC §210.12(A)) Residential Plan Check Correction List Page 2 of 5 4,�L'ju1�c!a Informational item: Please note that this requirement requires protection of the entire branch circuit supplying outlets (luminaires, fans, smoke alarms, etc.) and the devices within dwelling unit. 17) Note on Electrical Plan: "Modified, replaced, or extended 120 -volt, single phase, 15- and 20 -ampere branch circuits supplying outlets or devices installed in dwelling unit kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas or similar rooms or areas shall be protected by either a listed combination -type AFCI located at the origin of the branch circuit or a listed outlet branch -circuit type AFCI located at the first receptacle outlet of the existing branch circuit." (CEC §210.12(B)) 18) Kitchen, pantries, breakfast rooms, dining rooms, and similar area receptacles shall comply with the following: (CEC §210.52(C)): a) Provide a receptacle outlet at each wall counter space 12 inches or wider. b) Provide receptacle outlets at each wall counter so that no point along the wall line is more than 24 inches, measured horizontally from a receptacle outlet in that space. c) Provide at least one receptacle outlet at each island counter space with a long dimension of 24 inches or greater and a short dimension of 12 inches or greater. d) Provide at least one receptacle outlet at each peninsular counter space with a long dimension of 24" or greater and a short dimension of 12" or greater. A peninsular countertop is measured from the connecting edge. Informational item: Receptacle outlets shall be installed not more than 20 inches above the countertop. Receptacle outlets rendered not readily accessible by appliances fastened in place or appliances occupying dedicated space shall not be considered as these required outlets. 19) Provide at least one receptacle outlet in areas designated for the installation of laundry equipment. (CEC §210.11(C)(2) & 210.52(F)) 20) Provide at least one receptacle outlet in each car space located within an attached garage. (CEC §210.52(G)(1)) 21) Provide at least one receptacle outlet in hallway 10 feet or more in length. (CEC §210.52(H)) 22) Provide in every kitchen, family room, dining room, living room, parlor, library, den, sun room, bedroom, recreation room, or similar room or area of dwelling units, receptacle outlets so that no point along the floor line in any wall space is more than 6 feet, measured horizontally, from an outlet in that space, including any wall space 2 feet or more in width and the wall space occupied by fixed panels in exterior walls, but excluding sliding panels in exterior walls. The wall space afforded by fixed room dividers, such as freestanding bar -type counters or railings, shall be included in the 6 -foot measurement. (CEC §210.52(A)) See Plan for locations not meeting this requirement. Informational item: As used in this section, a "wall space" shall be considered a wall unbroken along the floor line by doorways, fireplaces, fixed cabinets and similar openings. Each wall space 2 feet or more in width shall be treated individually and separately from other wall spaces within the room. A wall space shall be permitted to include two or more walls of a room (around corners) where unbroken at the floor line. Receptacle outlets shall, insofar as practicable, be spaced equal distances apart. Receptacle outlets in floors shall not be counted as part of the required number of receptacle outlets unless located within 18 inches of the wall. The receptacle outlets required by this section shall be in addition to any receptacle that is part of any lighting fixture or appliance, located within cabinets or cupboards, or located over 5-1/2 feet above the floor. 23) Provide at least one wall switch -controlled lighting outlet in every habitable room; in bathrooms, hallways, stairways, attached garages, and detached garages with electric power; and at the exterior side of outdoor entrances or exits. (CEC §210.70(A)) See Plan for locations not in compliance. Residential Plan Check Correction List Page 3 of 5 .. 4 4Qum& 24) Provide at least one lighting outlet controlled by a light switch located at the po nt of entry to the attic, underfloor space, utility room, and basement where these spaces are used for storage or contain equipment requiring servicing. The lighting outlet shall be provided at or near the equipment requiring servicing. (CEC §210.70(A)(3)) See Plan for locations not in compliance. 25) Specify a weather -resistant type receptacle at all 15- and 20 -ampere, 125- and 250 -volt receptacles where located in damp or wet locations. (CEC §406.9(A) & (B)) 26) Specify a tamper-resistant type receptacle in all 125 -volt, 15- and 20 -ampere receptacles located in areas required by 210.52 and located within 5-1/2 feet of the floor. (CEC §406.12(A)) 27) Show on Plans how luminaires (light fixtures) in clothes closets conform to the fallowing: (CEC §410.16(C)) a) Twelve (12) inches - Surface -mounted incandescent of LED luminaires with a completely enclosed light source installed on the wall above the door or on the ceiling. b) Six (6) inches - Surface -mounted fluorescent luminaires installed on the wall above the door or on the ceiling. c) Six (6) inches - Recessed incandescent or LED luminaires with a completely enclosed light source installed in the wall or the ceiling. d) Six (6) inches - Recessed fluorescent luminaires installed in the wall or the ceiling. e) Surface -mounted fluorescent or LED luminaires shall be permitted to be inst•31led within the closet storage space where identified for this use. 28) Note on Plans: "Luminaires (light fixtures) in tub or shower enclosures shall be labeled 'suitable for damp location'." (CEC §410.10(D)) 29) No parts of cord -connected luminaires, chain-, cable -,'or cord -suspended luminaires, lighting track, pendants, or ceiling -suspended fans shall be located within three (3) feet horizontally and eight (8) feet vertically from the top of the bathtub rim or shower stall threshold. (CEC §410.10(1))) SECTION G - ENERGY EFFICIENCY 1) All luminaires shall be high efficacy in accordance with Table 150.0-A. Specify in .ighting schedule for each luminaire, the luminaire and lamp types, wattage and whether light source requ res certification with Reference Joint Appendix JAB, such as required for all screw -base luminaires and recessed down lighting. (CEC §150.0(k)1A) See electrical plan for areas not in compliance. 2) All down light luminaires recessed in ceilings (not just those in insulated ceilings: must meet the following requirements: (CEC §150.0(k)1C) a) Shall contain light sources that are certified JAB compliant that are not of the screw -based type; and b) Those that are enclosed, such as those often used in showers, must utilize a JA8-E compliant lamp rated for use at elevated temperatures; and c) Be listed for zero -clearance insulation contact (IC Rated) by a nationally recognized testing lab that are certified airtight per ASTM E283-04 (air leakage less than 2.0 CFM at 75 Pascals); and d) Have a gasket or caulked sealing between the luminaire housing and ceiling; and e) Allow readily accessible ballasts for maintenance or replacementwithout needing to cut holes in the ceilings. 3) Lighting shall be switched separately from exhaust fans and when provided under cabinets from other lighting systems. (CEC §150.0(k)2B & L) 4) .In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire must be controlled by a vacancy sensor. (CEC §150:0(k)2J) See electrical plan for areas not in compliance. 5) All interior luminaires required to have light sources compliant with Joint Appendix JA8 must be controlled by either a dimmer or vacancy sensor, except those located in closets less than :'0 square feet or hallways. Residential Plan Check Correction List Page 4 of 5 L (CEC §150.0(k)2K) See electrical plan for areas not in compliance. .6) Outdoor lighting permanently. mounted to the building must be controlled by on.? of the following combinations and a manual ON/OFF switch that does not override the chosen combination: (CEC §150.0(k)3) a) Photocell and motion sensor b) Photo control and automatic time switch c) Astronomical time clock d) EMCS with features of an astronomical time clock that does not allow the luminaire to be always ON, and is programmed to automatically turn lighting OFF during daylight hours.. SECTION K - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List Page 5 of 5 r i r Page 5 of 5 C�(ts rr : , n`�: C�lbtci{� L1 1 . Vr'DV C.L+ v6t- �"- tLoD Z D-t2M I.,''4CWCt,1 G r"k +b cV V{' Ck IRM I SiIUt , L�ti ;t �Lc�atr .I.v i<Gt4.;�iGCy Irk, AOW ea•., ` �p a'� C Cary Ck 6i L Y ^ 11 , p151r>u,a r QY{� . SkCtn Glvcu� � ` tC+ U ouflt1> ((a 21u.11(00)o�a 2tDc�jZCv�(,1)-#e�.� Y1'�t�.'.?L=� �" 1�\112tYv0\�i,,,� cA� • - 3 �) 1 r11D-a..rrl eVI (ti�):CALF 2. Qr\,)v \d -t Ctk >; t G ,,-F tmC. OArvy bYa.',*- C -h C(,( uw A- -{ o 4 c cx.11 0.r' a 3 � � � 1 ri, '�1k�t r \\qq%Gt �Ct{ �Y itis' I�1 � A Lt�fiOt3 G� ;