Loading...
BWFE2018-001178-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Tit�p 4 4 w DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: WALL/FENCE/CITY STANDARD/PRE-APPROVED Application Number: BWFE2018-0011 Property Address: 54510 AVENIDA VALLEJO APN: 774282001 Application Description: CORONEL / BLOCK WALL Property Zoning: Application Valuation: $2,500.00 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: SPIEGEL DEV 54510 AVENIDA VALLEJO LA QUINTA, CA 92253 Date: 1/16/2018 Applicant: Contractor: CORONEL ENTERPRISES INC ® CORONEL ENTERPRISES INC 42760 MADIO STREET i 42760 MADIO STREET INDIO, CA 92201 JAN 16 6 2018. INDIO, CA 92201 CITM Q� (760)775-1234 DESIGNANp p LA QUINTA Llc. No.: 727199 EVEIOPMENTpEPARTy %r -- %r ------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B,._ License No.: 72719-9 _ /1 D* —lL - l cabiocto, OWNER -BUILDER DECLARATION . I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an.owner of property who builds or improves thereon, and who contracts for'the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code,.for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: BENCHMARK INSURANCE COMPANY Policy Number: CST5009346 _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of Californla, and agree that, if I should become subject to the workers' compensation provisions of Sec ljOn 3780 of thLabor Co�e� I shall forthwith comply with those provisions. `\ f I WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE 15 UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION; DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application: 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or, following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of thi;,city r enter rn�the above-mentioned property for inspection purposes. Dates ( 6—1ant or Agen r Date: 1/16/2018 Application Number: BWFE2018-0011 Owner: Property Address: 54510 AVENIDA VALLEJO SPIEGEL DEV APN: 774282001 54510 AVENIDA VALLEJO Application Description: CORONEL / BLOCK WALL LA QUINTA, CA 92253 Property Zoning: Application Valuation: $2,500.00 Applicant: Contractor: CORONEL ENTERPRISES INC CORONEL ENTERPRISES INC 42760 MADIO STREET 42760 MADIO STREET INDIO, CA 92201 INDIO, CA 92201 (760)775-1234 Llc. No.: 727199 Detail: 50 LF OF 8' GARDEN WALL [ANGELUS SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE. THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. PER 2016 CALIFORNIA BUILDING CODES o . r I Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 n FINANCIAL DESCRIPTION INFORMATION ACCOUNT QTY . AMOUNT RETAINING/COMBINATION WALL EA 50LF 101-0000-42400 .0 $15.60 DESCRIPTION ACCOUNT QTY AMOUNT WALL/FENCE - FIRST 100 LF 101-0000-42404 0 $52.01 DESCRIPTION ACCOUNT QTY AMOUNT WALL/FENCE - FIRST 100 LF PC 101-0000-42600 0 $65.02 Total Paid for BLOCK WALL: $132.63 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNTQTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT QTY. AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 .$5.00 I Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 n 11 GHL INC. A":HIiz.'II;RE. - N(ANEERI;N(i 228 East Badillo Streo I Covina, CA 91723 626938,.1595 F: 626998,0085 w�nw,yLlva.com CITY OF LA QUINTA BUILDING DIVISION APPROVED FOR CONSTRUCTION BY: A. f(j_,j„ DATE: 04/27/2017 * EXP. 9-30-181* ��_1115F �vc\ox�\051/& DATE SIGNED 4-12-17 S-1.6LQ #16-077 6' High Wall 2' to 4' Retaining 0§0L0C Heel -in Footing C ®110mph (ult.) Since 1946 ANGELUS BLOCK MASONRY FENCE WALL SYSTEM Risk Category I DESIGN CRITERIA: 6"/8" Wide CMU 1. DESIGN CRITERIA PER 2016 CBC 2. ALLOWABLE SOIL BEARING PRESSURE = 1500psf OPTIONAL WALL CAP' 3. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf 4. COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf 5. CANTILEVER ACTIVE = 30pcf 6. MASONRY COMPRESSIVE STRENGTH, Vm = 1500ps1. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE LADDER TYPE PROJECT SPECIFIC SITE. #5 STD. FOR SLUMPSTONE) JOINT REINF, AT TOP COURSE.: ' AT FIRST COURSE, AND 34"ti.c.. 1• REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 AT FENCE 'H' + 12" GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS.... 8" WIDE (NOM:) CMU DISTANCE TO EDGE OF w/ ''Y BARS PER NEAREST ADJACENT 2. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD–DRAWN STEEL SCHEDULE ® CTR. FOUNDATION r WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES, OF WALL. GROUT CELLS w/ REINF. 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi ®28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. a 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS #4 HORIZ. 024'o.c. BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR 0 RETAINING WITHOUT MORTARLESS HEAD JOINTS (TONGUE–AND–GROOVE), OR OPTIONAL CHAMFER ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 4"0 SOR 35 PERF. PIPE w/ BACKFILL - 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS 1C.f. 3/4" GRAVEL WRAPPED IN WELL GRADED, CLEAN MANUFACTURED BY E–Z MIX INC., CONFORMING TO PROPORTIONS AND MIRAFI 140N FILTER FABRIC– SANDS OR GRAVEL OR REQUIREMENTS OF ASTM C270, OR SPEC MIX INR MASONRY MORTAR AS SLOPE TO DRAIN. WATERPROOF COMBINATION MANUFACTURED BY E–Z MIX INC., CONFORMING TO PROPERTY BACKSIDE OF RETAINING WALL USC= GW,GP OR SW,SP REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, 8" WIDE (NOM.) CMU AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF FULLY GROUTED 2000ps1. 2j"OUTSIDE FACE 7. FIRST COURSE MAY BE WET–SET 1 1/2 INCHES MAX. WHILE CONCRETEX' BARS PER OF BLOCK TO o IS PLASTIC. SCHEDULE, LAP ' x 8. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH 24" MIN. _ 0 VERTICAL CONTINUITY OF THE CELLS.F G �� ._;,` w 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'-0"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR WET–SET FIRST io • z: MORTAR WASHED . COURSE 10. GROUT ALL CELLS WITH REINFORCEMENT.; #4 CONT. N 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL #4 CONT. ® 12"o.c. , — — •— FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL , REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. M1 12. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK–OUT DETAILS CONT. CONC. FTG. R" SEE DETAIL SHEET S-5.1. 13. DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE CONC. KEY .. 12" 12" MASONRY FENCE RETAINING WALL SCHEDULE H, X' BARS- Y' BARS B' MIN. C' MIN. 'B' MIN. 16" LONG CMU 16" LCNC CMU 77-- 4032 o.c. 4®48o.c. 2'=9" N A PER SCHEDULE LOADING 2'-8" 4032"o.c. 4048"o.c. 3'=0" N/A Q� Oil 1. SEISMIC, 5% DAMPING 0 1 SECOND 9� 3'-4" 4032"o.c. 4048"o.c. 3'-5" N A ACCELERATION Cs=0.33Wt. 2. FOUNDATION SIZES BASED ON MAXIMUM WIND OR SEISMIC . 4'-0" 4032"o.c. I #4048"o.c. 1. 3'-11 1 0'-2" LOADING. tj stn .oa o, 1n' GHL INC. A":HIiz.'II;RE. - N(ANEERI;N(i 228 East Badillo Streo I Covina, CA 91723 626938,.1595 F: 626998,0085 w�nw,yLlva.com CITY OF LA QUINTA BUILDING DIVISION APPROVED FOR CONSTRUCTION BY: A. f(j_,j„ DATE: 04/27/2017 * EXP. 9-30-181* ��_1115F �vc\ox�\051/& DATE SIGNED 4-12-17 S-1.6LQ #16-077