Loading...
BCOM2018-001078-495.CALLE TAMPICO D haw LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: . BUILDING COMMERCIAL/REMODEL Application Number: BCOM2018-0010 Property Address: 4610.0 WASHINGTON ST APN: 604050038 Application Description: DESERT NEUROLOGY & SLEEP / 4,560SF TI/V6/B-OCC/46-OL/SPRINK Property Zoning: Application Valuation: $190,000.00 Applicant: GABRIEL LUJAN & ASSOCIATES 77530 ENFIELD LN BLDG I STE 101 PALM DESERT, CA 92211 LICENSED CONTRACTOR'S' DECLARATION I hereby affirm under penalty of perjury that l am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B A License No.: 693077 (Da e: 3 /S Contracto7: OW= DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License -Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State :License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( 11, as owner of the property, am exclusively contracting with licensed contractors to constructthe project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (� I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.)'. Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/15/2018 Owner: AJE DESERT VENTURES LLC 46100 WASHINGTON ST LA QUINTA, CA 92253 Contractor: ORR BUILDERS 39-301 BADGER STREET STE 300 PALM DESERT, CA 92211 (760)360-6632 Llc. No.: 693077 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of thew k for which this permit is issued. ave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 9213286 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Datesly/�Applica WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes. Da� 3 / Ste/ ` Signatu�(AppIican Date: 3/15/2018 Application Number: - BCOM2018-0010 Owner: Propertq'Adttresr- 46100 WASHINGTON ST AJE DESERT VENTURES LLC APN: 604050038 46100 WASHINGTON ST Application Description: DESERT NEUROLOGY & SLEEP / 4,5605F TI/VB/B-OCC/46-OL/SPRINK LA QUINTA, CA 92253 Property Zoning: Application Valuation: $190,000.00 Applicant: Contractor: GABRIEL LUJAN & ASSOCIATES ORR BUILDERS 77530 ENFIELD LN BLDG I STE 101 39-301 BADGER STREET STE 300 PALM DESERT, CA 92211 PALM DESERT, CA 92211 (760)360-6632 Llc. No.: 693077 -------------------------------------------------------------------------------------------- Detail: 4,560SF OFFICE TI/VB/B-OCC/46-OL/SPRINKLED [DESERT NEUROLOGY & SLEEP] THIS PERMIT DOES NOT INCLUDE ALTERATION TO EXISTING LOAD BEARING AND LATERAL RESISTING CONSTRUCTION OR EXISTING SITE, OSPHD REVIEW OR APPROVAL, OR BUILDING SIGNAGE: TUMF FEE NOT ASSESSED DUE TO REDUCED TRIP GENERATION RATE. 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNTQTY AMOUNT' ART IN PUBLIC PLACES - COMMERCIAL REMOD 270-0000-43201 1 0 $450.00 Total Paid for ART IN PUBLIC PLACES - AIPP: $450.00 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $8.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $8.00 DESCRIPTION ACCOUNT QTY AMOUNT NON-RESIDENTIAL, EA ADDITION 2,0005F 101-0000-42403. 0 $78.02 DESCRIPTION ACCOUNT QTY AMOUNT NON-RESIDENTIAL, EA ADDITION 2,000SF, PC 101-0000-42600 0 $20.80 DESCRIPTION ACCOUNT QTY AMOUNT NON-RESIDENTIAL, FIRST 2,000SF 101-0000-42403 0 $117.03 DESCRIPTION ACCOUNT QTY AMOUNT NON-RESIDENTIAL, FIRST 2,000SF, PC 101-0000-42600 0 $90.50 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $306.35 DESCRIPTION ACCOUNT QTY AMOUNT FIRE COMMERCIALTI PC 101-0000-42420 0 $234.00 Total Paid for FIRE FEES: $234.00 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN 101-0000-42402 0 $52.00 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN PC 101-0000-42600 0 $20.80 Total Paid for MECHANICAL: $72.80 DESCRIPTION ACCOUNT QTY AMOUNT PLAN CHECK DEPOSIT - ADDITION/REMODEL 101-0000-42600 1 $125.00 Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $130.00 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42660 0 $130.00 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $13.00 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 .$7.80 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $13.00 . DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $13.00 Total Paid for PLUMBING FEES: $306.80 DESCRIPTION ACCOUNT I QTY AMOUNT RECORDS MANAGEMENT FEE-- MAJOR I101-0000-42416 0 ) $20.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $20.00 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $210.69 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $168.48 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 100 SF 101-0000-42400 0. $53.05 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 0 $145.12 Total Paid for REMODEL: $577.34 DESCRIPTION ACCOUNT QTY AMOUNT SMI - COMMERCIAL 101-0000-20308 0 $53.20 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $53.20 DESCRIPTION ACCOUNT QTY 'AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 Bin # City of La Quina- Building 8r Safety Division P.O. Box 1504,78-495 Calle Tampico La .Quints, CA 92253 -:(760) 777-7012 Building Permit Application and Tracking Sheet Permit # G P,a Project Address: 46-100 Washington St. Owner's Name:. Dr. Elhajjar A. P. Number. Address: 46-100 Washington St. Legal Description: Contractor: To'Be Determined`'°'~' City, ST, Zip: La Quinta, Ca. 92253 Telephone: Address: Project Description: A tenant improvement for a City, ST, Zip: Medical Sleep Clinic of approximately Telephone: 4,546 Sq. Ft. consisting of electrical, mechanical State Lic. # :City Lia #; plumbing and faming work Arch., Engr., Designer. Gabriel Lujan & Associates. . Address: 77-530 Enfield Ln. Bldg. I-Ste. 101 City, ST, zip: palm Desert, CA. Telephone: 760.578.8545 Construction Type:. VB Occupancy: B State Lic. #: Project type (circle one): New Add'n Alter Repair Demo Name of contact person: Gabriel LujanSq. Ft.: 4,546 # Stories: 1 #Units: Telephone # of Contact Person: 760.578.8545 Estimated value of Project: 190,000.00 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRAgMG PERMIT FEES Plan Sets Plan Cheek submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit. . Truss Cales. Called Contact Person Plan Check Balance • Title 24 Calm. Plans picked up Construction ' Flood plain plan Plans resubmitted Mecharikal Grading plan 2i8 Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S bLL H.O.A. Approval Plans resubmitted Grading IN ROUSE:- '^' Review; ready for correetionsAssue Developer 3mpaet Fee Planning Approval Called Contact Person AA.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees • BUILDING ENERGY ANALYSIS REPORT PROJECT: Desert Neurology & SleepTl 46-100 Washington Street La Quinta, CA 92253 Project Designer: Gabriel Lujan & Associates 77-530 Enfield Lane, Suite 101 Palm Desert, CA 92211 (760) 578-8545 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 74-818 Velie Way, Suite #8 Palm Desert, CA 92260 (760) 200-4780 CITY OF LA QUINT, BUILDING & SAFETY DEP' ,APPROVED ¢. FOR CONSTRUCTION DAT61 %BYE_ Job Number: RECEIVED MAR 0 i 2018 Date: CITY OF LA QUINTA COMMUNITY DEVELOPMENT 3/6/2018 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. 9J 0 Project Name: Dr. Elhajar TI NRCC-PRF-01-E Page 1 of 16 Project Address: 46-100 Washington Street La Quinta 92253 Calculation Date/Time: 12:18, Tue, Mar 06, 2018 Compliance Scope: ExistingAlteration Input File Name: Elhajar DR. TI-LQ-GLA-17.cibdl6x A. PROJECT GENERAL INFORMATION § 140.1 1. Project Location (city) La Quinta 8. Standards Version Compliance2016 2. CA Zip Code 92253 9. Compliance Software (version) EnergyPro 7.2 3. Climate Zone 15 10. Weather File PALM-SPRINGS-INTL_722868_CZ2010.epw 4. Total Conditioned Floor Area in Scope 4,667 ftz 11. Building Orientation (deg) (E) 135 deg S. Total Unconditioned Floor Area 0 ft2 12. Permitted Scope of Work ExistingAlteration 6. Total # of Stories (Habitable Above Grade) 1 13 Building Type(s) Nonresidential 7. Total # of dwelling units 0 14 Gas Type NaturalGas B. COMPLIANCE RESULTS FOR PERFORMANCE COMPONENTS (Annual TDV Energy Use, kBtu/ft 2 -yr) § 140.1 BUILDING COMPLIES 1. Energy Component 2. Standard Design (TDV) 3. Proposed Design (TDV) 4. Compliance Margin (TDV) S. Percent Better than Standard Space Heating 0.63 0.85 -0.22 -34.9% Space Cooling 187.64 178.16 9.48 5.1% Indoor Fans 134.00 122.83 11.17 8.3% Heat Rejection -- -- -- -- Pumps & Misc. -- -- -- Domestic Hot Water 7.27 7.27 -- 0.0% Indoor Lighting 78.30 35.37 42.93 54.8% COMPLIANCE TOTAL 407.84 344.48 63.36 15.5% Receptacle 110.86 110.86 0.0 0.0% Process -- -- -- -- Other Ltg .Process Motors TOTAL 518.70 455.34 63.4 12.2`Yo CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-122020178-5302 Report Generated at: 2018-03-06 12:18:28 Project Name: Dr. Elhajar TI NRCC-PRF-01-E Page 2 of 16 Project Address: 46-100 Washington Street La Quinta 92253 Calculation Date/Time: 12:18, Tue, Mar 06, 2018 Compliance Scope: ExistingAlteration Input File Name: Elhajar DR. TI-LQ-GLA-17.cibdl6x C. PRIORITY PLAN CHECK/ INSPECTION ITEMS (in order of highest to lowest TDV energy savings) 1st Indoor Lighting: Check lighting Compliance Margin By Energy Component (from Table B column 4) Cnedrt 2nd Indoor Fans: Check envelope and mechanical Indoor Lighting Indoor Fans Space Cooling Heat RejectionPumps & Misc. Domestic Hot Water Space Heating Energy 3rd Space Cooling: Check envelope and mechanical 4th Heat Rejection: Check envelope and mechanical 5th Pumps & Misc.: Check mechanical 6th Domestic Hot Water: Check mechanical 7th Space Heating: Check envelope and mechanical _ Penalty D. EXCEPTIONAL CONDITIONS The building does not include service water heating. Verify that service water heating is not required and is not included in the design. This project uses the Simplified Geometry Performance Modeling Approach which is not capable of modeling daylighting controls and assumes the prescriptive Secondary Daylit Control requirements are met. PRESCRIPTIVE COMPLIANCE documentation (form NRCC-LTI-02-E) for the requirements of section 140.6(d) Automatic Daylighting Controls in Secondary Daylit Zones is required. The proposed building includes space(s) that are modeled with unknown HVAC system(s). Verify that the spaces modeled with unknown HVAC system(s) are either part of core and shell analysis which will be permitted for mechanical compliance in the future, or the spaces have an existing HVAC system not modeled for compliance, or the compliance scope does not include mechanical. E. HERS VERIFICATION This Section Does Not Apply F. ADDITIONAL REMARKS None Provided CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-122020178-5302 Report Generated at: 2018-03-06 12:18:28 Project Name: Dr. Elhajar TI NRCC-PRF-01-E Page 3 of 16 Project Address: 46-100 Washington Street La Quinta 92253 Calculation Date/Time: 12:18, Tue, Mar 06, 2018 Compliance Scope: ExistingAlteration Input File Name: Elhajar DR. TI-LQ-GLA-17.cibdl6x G. COMPLIANCE PATH & CERTIFICATE OF COMPLIANCE SUMMARY Identify which building components use the performance or prescriptive path for compliance. "NA"= not in project For components that utilize the performance path, indicate the sheet number that includes mandatory notes on plans. Building Component Compliance Path Compliance Forms (required for submittal) Location of Mandatory Notes on Plans Envelope ® Performance NRCC-PRF-ENV-DETAILS (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-ENV-01 / 02 / 03 / 04 / 05 / 06-E ❑ NA Mechanical ❑ Performance NRCC-PRF-MCH-DETAILS (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-MCH-01 / 02 / 03 / 04 / 05 / 06 / 07-E ® NA Domestic Hot Water ❑ Performance NRCC-PRF-PLB-DETAILS (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-PLB-01-E ❑ NA Lighting (Indoor Conditioned) ® Performance NRCC-PRF-LTI-DETAILS (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-LTI-01 / 02 / 03 / 04 / 05-E ❑ NA Covered Process: Commercial Kitchens ❑ Performance S2 (section of the NRCC-PRF-01-E) ElPrescriptive NRCC-PRC Ol/03-E ® NA Covered Process: Computer Rooms ❑ Performance S3 (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-PRC-01/ 04E ® NA Covered Process: Laboratory Exhaust ❑ Performance S4 (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-PRC Ol/ 09-E ® NA CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-122020178-5302 Report Generated at: 2018-03-06 12:18:28 Project Name: I Dr. Elhajar TI NRCC-PRF-01-E Page 4 of 16 Project Address: 46-100 Washington Street La Quinta 92253 Calculation Date/Time: 12:18, Tue, Mar 06, 2018 Compliance Scope: ExistingAlteration Input File Name: Elhajar DR. TI-LQ-GLA-17.cibd16x G. COMPLIANCE PATH & CERTIFICATE OF COMPLIANCE SUMMARY The following building components are only eligible for prescriptive compliance. Indicate which are The following building components may have mandatory requirements per Part 6. Indicate relevant to the project. which are relevant to the project.. Yes NA Prescriptive Requirement Compliance Forms ' Yes NA Mandatory Requirement Compliance Forms Lighting (Indoor Commissioning: §120.8 ❑ ® Unconditioned) §140.6 NRCC-LTI-01 / 02 / 03 / 04 / 05-E ❑ ® Simple Systems NRCC-CXR-01 / 02 / 03 / 05-E ❑ ® Complex Systems NRCC-CXR-01 / 02 / 04 / 05-E ❑ ® Lighting (Outdoor) §140.7 NRCC-LTO-01 / 02 / 03-E ❑ ® Electrical: §130.5 NRCC-ELC-01-E ❑ ® Lighting (Sign) §140.8 NRCC-LTS-01-E ❑ ® Solar Ready: §110.10 NRCC-SRA-01 / 02-E Covered Process: §120.6 NRCC-PRC-01-E ❑ ® Parking Garage NRCC-PRC-02-E ❑ ® Solar Thermal Water Ol E ❑ ® Commercial Refrigeration NRCC-PRC-05-E Heating:NRCC-STH §140.5 ❑ ® Warehouse Refrigeration NRCC-PRC-06/07/08-E ❑ ® Compressed Air NRCC-PRC-10-E ❑ ® Process Boilers NRCC-PRC-11-E CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-122020178-5302 Report Generated at: 2018-03-06 12:18:28 • Project Name: Dr. Elhajar TI NRCC-PRF-01-E Page 5 of 16 Project Address: 46-100 Washington Street La Quinta 92253 Calculation Date/Time:12:18, Tue, Mar 06, 2018 Compliance Scope: ExistingAlteration Input File Name: I Elhajar DR. TI-LQ-GLA-17.cibdl6x H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCI/NRCA/NRCV) — Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment. Confirmed Building Component Compliance Forms (required for submittal) Pass Fail Envelope ® NRCI-ENV-01-E - For all buildings E] El ® NRCA-ENV-02-F- NFRC label verification for fenestration ❑ ❑ Mechanical ❑ NRCI-MCH-01-E - For all buildings with Mechanical Systems ❑ ❑ ❑ NRCA-MCH-02-A- Outdoor Air ❑ ❑ ❑ NRCA-MCH-03-A — Constant Volume Single Zone HVAC ❑ ❑ ❑ NRCA-MCH-04-H- Air Distribution Dud Leakage ❑ ❑ ❑ NRCA-MCH-05-A- Air Economizer Controls ❑ ❑ ❑ NRCA-MCH-06-A- Demand Control Ventilation ❑ ❑ ❑ NRCA-MCH-07-A — Supply Fan Variable Flow Controls ❑ ❑ ❑ NRCA-MCH-08-A- Valve Leakage Test ❑ ❑ ❑ NRCA-MCH-09-A —Supply Water Temp Reset Controls ❑ ❑ ❑ NRCA-MCH-10-A- Hydronic System Variable Flow Controls ❑ ❑ ❑ NRCA-MCH-1I-A—Auto Demand Shed Controls ❑ ❑ ❑ NRCA-MCH-12-A- Packaged Direct Expansion Units ❑ ❑ ❑ NRCA-MCH-13-A- Air Handling Units and Zone Terminal Units ❑ ❑ ❑ NRCA-MCH-14-A- Distributed Energy Storage ❑ ❑ ❑ NRCA-MCH-15-A —Thermal Energy Storage ❑ ❑ ❑ NRCA-MCH-16-A- Supply Air Temp Reset Controls ❑ ❑ ❑ NRCA-MCH-17-A — Condensate Water Temp Reset Controls ❑ ❑ ❑ NRCA-MCH-18-A- Energy Management Controls Systems - ❑ ❑ ❑ NRCV-MCH-04-H- Duct Leakage Test ❑ ❑ CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-122020178-5302 Report Generated at: 2018-03-06 12:18:28 H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCI/NRCA/NRCV) — Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment. Confirmed Building Component Compliance Forms (required for submittal) Pass Fail Plumbing ❑ NRCI-PLB-01-E - For all buildings with Plumbing Systems ❑ ❑ ❑ NRCI-PLB-02-E - required on central systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCI-PLB-03-E - Single dwelling unit systems in high-rise residential, hotel/motel application. ❑ ❑ ElNRCI-PLB-21-E - HERS verified central systems in high-rise residential, hotel/motel application. ❑ El ❑ NRCI-PLB-22-E - HERS verified single dwelling unit systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCV-PLB-21-H- HERS verified central systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCV-PLB-22-H - HERS verified single dwelling unit systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCI-STH-01-E - Any solar water heating ❑ ❑ Indoor Lighting ® NRCI-LTI-01-E - For all buildings ❑ ❑ ❑ NRCI-LTI-02-E - Lighting control system, or for an Energy Management Control System (EMCS) ❑ ❑ ❑ NRCI-LTI-03-E - Line -voltage track lighting integral current limiter, or for a supplementary overcurrent protection panel used to energize only line -voltage track lighting ❑ ❑ ❑ NRCI-LTI-04-E - Two interlocked systems serving an auditorium, a convention center, a conference room, or a theater ❑ ❑ ❑ NRCI-LTI-05-E -Lighting Control Credit Power Adjustment Factor (PAF) ❑ ❑ ❑ NRCI-LTI-06-E - Additional wattage installed in a video conferencing studio ❑ ❑ ® NRCA-LTI-02-A - Occupancy sensors and automatic time switch controls. ❑ ❑ ® NRCA-LTI-03-A - Automatic daylighting controls ❑ ❑ ❑ NRCA-LTI-04-A - Demand responsive lighting controls ❑ ❑ Outdoor Lighting ❑ N RCI -LTO -01-E —Outdoor Lighting ❑ ❑ ❑ NRCI-LTO-02-E- EMCS Lighting Control System ❑ ❑ ❑ NRCA-LTO-02-A -Outdoor Lighting Control ❑ ❑ Sign Lighting ❑ NRCI-LTS-01-E—Sign Lighting ❑ ❑ Electrical ❑ NRCI-ELC-01-E - Electrical Power Distribution ❑ ❑ Photovoltaic ❑ NRCI-SPV-01-E Photovoltaic Systems ❑ ❑ CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-122020178-5302 Report Generated at: 2018-03-06 12:18:28 Project Name: Dr. Elhajar TI NRCC-PRF-01-E Page 7 of 16 Project Address: 46-100 Washington Street La Quinta 92253 Calculation Date/Time: 12:18, Tue, Mar 06, 2018 Compliance Scope: ExistingAlteration Input File Name: Elhajar DR. TI-LQ-GLA-17.cibdl6x H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCI/NRCA/NRCV) — Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment. Confirmed Building Component Compliance Forms (required for submittal) Pass Fail Covered Process ❑ NRCI-PRC-01-E Covered Processes ❑ ❑ . ❑ NRCA-PRC-01-F- Compressed Air Systems ❑ ❑ ❑ NRCA-PRC-02-F- Kitchen Exhaust ❑ ❑ ❑ NRCA-PRC-03-F-Garage Exhaust ❑ ❑ ❑ NRCA-PRC-04-F- Refrigerated Warehouse- Evaporator Fan Motor Controls ❑ ❑ ❑ NRCA-PRC-05-F- Refrigerated Warehouse- Evaporative Condenser Controls ❑ ❑ ❑ NRCA-PRC-06-F- Refrigerated Warehouse- Air Cooled Condenser Controls ❑ ❑ ❑ NRCA-PRC-07F- Refrigerated Warehouse- Variable Speed Compressor ❑ ❑ ❑ NRCA-PRC-08-F- Electrical Resistance Underslab Heating System ❑ ❑ t. ENVELOPE GENERAL INFORMATION (See NRCC-PRF-ENV-DETAILS for more information) 1. Total Conditioned Floor Area 4,667 ft2 S. Number of Floors Above Grade 1 Confirmed 2. Total Unconditioned Floor Area 0 ft2 6. Number of Floors Below Grade 0 V N = 3. Addition Conditioned Floor Area 0 ft2 4. Addition Unconditioned Floor Area 0 ft2 7. Opaque Surfaces & Orientation 8. Total Gross Surface Area 9. Total Fenestration Area 10. Window to Wall Ratio North Wall 570 ft2 175 ft2 30.7% ❑ ❑ East Wall 590 ft2 187 ft2 31.7% ❑ ❑ South Wall 858 ft2 220 ft2 25.6% ❑ ❑ West Wall 525 ft2 136 ft2 25.9% ❑ ❑ Total 2,543 ft2 718 ft2 28.2% ❑ ❑ Roof 4,667 ft2 0 ft2 00.0% ❑ ❑ CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-122020178-5302 Report Generated at: 2018-03-06 12:18:28 -0 Project Name Project Address: Compliance Scope Dr. Elhajar TI 46-100 Washington Street La Quinta 92253 ExistingAlteration NRCC-PRF-01-E Page 8 of 16 Calculation Date/Time: 12:18, Tue, Mar 06, 2018 Input File Name: Elhajar DR. TI-LQ-GLA-17.cibdl6x • J. FENESTRATION ASSEMBLY SUMMARY § 110.6 Confirmed 1. 2. 3. 4. S. 6. 7. 8. 9. Surface Name Surface Type Area (ft') Framing Type Cavity R -Value Continuous R -Value U -Factor / F -Factor / C -Factor d C N � N T R-19 Roof rafter6 Roof Fenestration Assembly Name / Fenestration Type / Product Type1 19 NA U -Factor: 0.052 Overall Overall Overall d ExteriorWall 2543 Wood 11 Certification Method' Assembly Method Area ft ❑ ❑ Slab On Grade34 Underground Floor 4667 NA Tag or I.D. / Frame Type F -Factor: 0.730 E ❑ U-factor SHGC VT N Vertical Fenestration Single Metal Tinted Fixed Window Default Performance SiteBuilt 605 1.04 0.63 0.77 E ❑ ❑ NonMetalFraming Vertical Fenestration Dual Metal Tinted OperableWindow NFRC Rated Manufactured 113 0.52 0.39 0.50 A ❑ ❑ N/A ' Newly installed fenestration shall hove a certified NFRC Label Certificate or use the CEC default tables found in Toble 110.6-A and Table 110.6.8. Center of Gloss (COG) values are for the gloss -only, determined by the manufacturer, and are shown for ease of verification. Site -built fenestration values are calculated per Nonresidential Appendix NA6 and are used in the analysis. 1 Status: N - New, A -Altered, E- Existing ' Taking compliance credit for fenestration shading devices? (if "Yes", see NRCC-PRF-ENV-DETAILS for more information) No K. OPAQUE SURFACE ASSEMBLY SUMMARY § 120.7/ § 140.3 Confirmed 1. 2. 3. 4. S. 6. 7. 8. Surface Name Surface Type Area (ft') Framing Type Cavity R -Value Continuous R -Value U -Factor / F -Factor / C -Factor d C N � N T R-19 Roof rafter6 Roof 4667 Wood 19 NA U -Factor: 0.052 E ❑ ❑ Default Wa118 ExteriorWall 2543 Wood 11 NA U -Factor: 0.110 E ❑ ❑ Slab On Grade34 Underground Floor 4667 NA 0 NA F -Factor: 0.730 E ❑ ❑ ' Status: N -New, A -Altered, E -Existing L. ROOFING PRODUCT SUMMARY § 140.3 Confirmed 1. 2. 3. 4. 5. 6. 7. ProductType Product Density Aged Solar Thermal SRI Cool Roof Roofing Product � T - 1 (Ib/ft) Reflectance Emittance Credit Description R-19 Roof rafter6 5.895 0.08 0.75 NA No NA ❑ ❑ M. HVAC SYSTEM SUMMARY (see NRCC-PRF-MCH-DETAILS for more information) § 110.1 / § 110.2 Dry System Equipment Section Does Not Apply CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-122020178-5302 Report Generated at: 2018-03-06 12:18:28 Project Name: Dr. ElhajarTl NRCC-PRF-01-E Page 9 of 16 Project Address: 46-100 Washington Street La Quinta 92253 Calculation Date/Time: 12:18, Tue, Mar 06, 2018 Compliance Scope: ExistingAlteration Input File Name: Elhajar DR. TI-LQ-GLA-17.cibdl6x Wet System Equipment Section Does Not Apply V. ECONOMIZER & FAN SYSTEMS SUMMARY' § 140.4 'his Section Does Not Apply 0. EQUIPMENT CONTROLS § 120.2 Fhis Section Does Not Apply 3. SYSTEM DISTRIBUTION SUMMARY § 120.4/ § 140.4(i) rhis Section Does Not Apply Multifamily or Hotel/ Motel Occupancy? (if "Yes", see NRCC-PRF-MCH-DETAILS for DHW system information) No Q. INDOOR CONDITIONED LIGHTING GENERAL INFO (see NRCC-PRF-LTI-DETAILS for more info)' § 140.6 Confirmed 1. 2. 3. 4. S. 1 Occupancy Type Conditioned Floor Area 2 Installed Lighting Power Lighting Control Credits Additional (Custom) Allowance V Nfu T (ft2) (Watts) (Watts) Area Category Footnotes Tailored Method (Watts) ❑ ❑ (Watts) Medical and Clinical Care 4,667 2,530 0 0 0 ❑ ❑ Building Totals: 4,667 2,530 0 0 0 'See Table 140.6-C 2 See NRCC-LTI-01-E for unconditioned spaces 3Lighting information for existing spaces modeled is not included in the table CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-122020178-5302 Report Generated at: 2018-03-06 12:18:28 Project Name: Dr. Elhajar TI NRCC-PRF-01-E Page 10 of 16 Project Address: 46-100 Washington Street La Quinta 92253 Calculation Date/Time: 12:18, Tue, Mar 06, 2018 Compliance Scope: ExistingAlteration Input File Name: Elhajar DR. TI-LQ-GLA-17.cibdl6x R. INDOOR CONDITIONED LIGHTING SCHEDULE (Adapted from NRCC-LTI-01-E)t § 130.0 Luminaire Schedule (includes all permanent installed lighting in Proposed Design Site (MWh) Margin (MWh) conditioned space, and portable lighting over 0.3 w/ftz in Installed Watts (Conditioned) Confirmed offices) -- -- -- Complete Luminaire Description (i.e., 2.5 How Wattage is Determined Space Cooling 28.3 26.7 1.6 Name or Item Ta Tag 3 -lam fluorescent troffer, F32T8, P Watts per luminaire P Total Number Luminaires Installed Watts Pass Fail CEC Default According to -- d one dimmable electronic ballast) from NAB §130.0(c) 2X4 LED 34 W LED 34 Yes No 58 1,972 ❑ ❑ Can LED 18 W LED 18 Yes No 31 558 ❑ ❑ 'If lighting power densities were used in the compliance model Building Departments will need to check prescriptive forms for Luminaire Schedule details. Sl. COVERED PROCESS SUMMARY — ENCLOSED PARKING GARAGES § 140.9 This Section Does Not Apply S2. COVERED PROCESS SUMMARY — COMMERCIAL KITCHENS § 140.9 This Section Does Not Apply S3. COVERED PROCESS SUMMARY— COMPUTER ROOMS § 140.9 This Section Does Not Apply S4. COVERED PROCESS SUMMARY — LABORATORY EXHAUSTS § 140.9 This Section Does Not Apply r. UNMET LOAD HOURS This Section Does Not Apply U. ENERGY USE SUMMARY Energy Component Standard Design Site (MWh) Proposed Design Site (MWh) Margin (MWh) Standard Design Site (MBtu) Proposed Design Site (MBtu) Margin (MBtu) Space Heating -- -- -- 1.9 2.5 -0.6 Space Cooling 28.3 26.7 1.6 -- -- -- Indoor Fans 29.2 26.7 2.5 -- -- d CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-122020178-5302 Report Generated at: 2018-03-06 12:18:28 L -I Project Name: - Dr. Elhajar TI NRCC-PRF-01-E Page 11 of 16 Project Address: 46-100 Washington Street La Quinta 92253 Calculation Date/Time: 12:18, Tue, Mar 06, 2018 Compliance Scope: ExistingAlteration Input File Name: I Elhajar DR. TI-LQ-GLA-17.cibdl6x U. ENERGY USE SUMMARY Energy Component Standard Design Site (MWh) Proposed Design Site (MWh) Margin (MWh) Standard Design Site (MBtu) Proposed Design Site (MBtu) Margin (MBtu) Heat Rejection Pumps & Misc. -_ -- -- Domestic Hot Water -- -- -- 23.6 23.6 0.0 Indoor Lighting 15.7 7.1 8.6 -- -- -- COMPLIANCE TOTAL 73.2 60.5 12.7 25.5 26.1 -0.6 Receptacle 21.3 21.3 0.0 14.5 14.5 0.0 Process -- -- -- -- -- Other Ltg Process Motors -- -- -- -- -- -- TOTAL 94.5 81.8 12.7 40.0 40.6 -0.6 CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-122020178-5302 Report Generated at: 2018-03-06 12:18:28 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT § 10-103 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Tim Scott Signature: Company: Scott Design and Title 24, Inc, Address: 74-818 Velie Way, Suite #8 Signature Date: City/State/Zip: Palm Desert CA 92260 CEA Identification (If applicable): Phone: (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1 I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. 2 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. 3 'affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document becaus ains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. Responsible Envelope Designer Name: Gabriel Lujan Company: Gabriel Lujan & Associates ignature: Address: 77-530 Enfield Lane, Suite 101 Date Signed: City/State/Zip: Palm Desert CA 92211 Declaration Statement Type: Phone: (760) 578-8545 Title: License #: Responsible Lighting Designer Name: Gabriel Lujan Company: Gabriel Lujan & Associates ignature: Address: 77-530 Enfield Lane, Suite 101 Date Signed: City/State/Zip: Palm Desert CA 92211 Declaration Statement Type: Phone: (760) 578-8545 Title: License #: Responsible Mechanical Designer Name: Tim Scott Company: Scott Design and Title 24, Inc. Signature: NOT IN SCOPE Address: 74-818 Velie Way, Suite #8 Date Signed: City/State/Zip: Palm Desert CA 92260 Declaration Statement Type: Phone: (760) 200-4780 Title: License #: CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-122020178-5302 Report Generated at: 2018-03-06 12:18:28 Project Name: Dr. Elhajar TI NRCC-PRF-01-E Page 13 of 16 Project Address: 46-100 Washington Street La Quinta 92253 Calculation Date/Time: 12:18, Tue, Mar 06, 2018 Compliance Scope: ExistingAlteration Input File Name: Elhajar DR. TI-LQ-GLA-17.cibdl6x NRCC-PRF-ENV-DETAILS -SECTION START A. OPAQUE SURFACE ASSEMBLY DETAILS Confirmed 1. 2. 3. 4. d — Surface Name Surface Type Description of Assembly Layers Notes Door Type Certification Method Asphalt shingles - 1/4 in. Area Overall LI -factor status' Pass Fail Vapor permeable felt - 1/8 in. WoodGreaterThanOrEqualTol.75inThickDoor DefauItPerformance Swinging R-19 Roof rafter6 Roof Plywood - 1/2 in. ❑ ❑ ❑ Air - Cavity - Wall Roof Ceiling - 4 in. or more Wood framed roof, 16in. OC, 5.5in., R-19 Gypsum Board -1/2 in. Stucco - 7/8 in. Default Wall8 ExteriorWall Vapor permeable felt - 1/8 in. ❑ ❑ Wood framed wall, 16in. OC, 3.5in., R-11 Gypsum Board - 1/2 in. Slab Type = UnheatedSlabOnGrade Slab On Grade34 UndergroundFloor Insulation Orientation = None ❑ ❑ Insulation R -Value = RO B. OVERHANG DETAILS (Adapted from NRCC-ENV-02-E) This Section Does Not Apply C. OPAQUE DOOR SUMMARY Confirmed 1. 2. 3. 4. S. 6. 7. Opaque Door Assembly Name / Tag or I.D. Door Type Certification Method Operation Area Overall LI -factor status' Pass Fail Wood Door13 WoodGreaterThanOrEqualTol.75inThickDoor DefauItPerformance Swinging 61 0.500 E ❑ ❑ I Status: N -New, A—Altered, E— Existing NRCC-PRF-MCH-DETAILS -SECTION START A. MECHANICAL VENTILATION AND REHEAT (Adapted from 2016-NRCC-MCH-03-E) This Section Does Not Apply CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-122020178-5302 Report Generated at: 2018-03-06 12:18:28 Project Name: Dr. Elhajar TI NRCC-PRF-01-E Page 14 of 16 Project Address: 46-100 Washington Street La Quinta 92253 Calculation Date/Time: 12:18, Tue, Mar 06, 2018 Compliance Scope: ExistingAlteration Input File Name: Elhajar DR. TI-LQ-GLA-17.cibdl6x B. ZONAL SYSTEM AND TERMINAL UNIT SUMMARY This Section Does Not Apply C. EXHAUST FAN SUMMARY This Section Does Not Apply D. DHW EQUIPMENT SUMMARY — (Adapted from NRCC-PLB-01) This Section Does Not Apply E. MULTI -FAMILY CENTRAL DHW SYSTEM DETAILS This Section Does Not Apply F. SOLAR HOT WATER HEATING SUMMARY (Adapted from NRCC-STH-03) This Section Does Not Apply G. MECHANICAL HVAC ACCEPTANCE TESTS & FORMS (Adapted from 2016-NRCC-MCH-01-E) § RA4 This Section Does Not Apply H. EVAPORATIVE COOLER SUMMARY This Section Does Not Apply NRCC-PRF-LTI-DETAILS -SECTION START- A. TART A. INDOOR CONDITIONED LIGHTING CONTROL CREDITS (Adapted from NRCC-LTI-02-E) § 140.6 Lighting Control Credits Schedule (includes all lighting controls installed in conditioned space for Control Credit Calculation Confirmed compliance credit per §140.6(a)2 and Table 140.6-A) V If Acceptance Test Required q Location in Occupancy Type (must meet Type/Description of Lighting Watts of Power Control Credit Building requirements of Table 140.6-A) Control (i.e., partial on occupancy # of Units Controlled Adjustment Watts sensor, manual dimming, etc.) Lighting Factor Pass Fail S -1 -Tenant Medical and Clinical Care -none specified 1 0.00 0 ❑ El Improvement S -1 -Tenant Medical and Clinical Care none specified 1 0.00 0 ❑ ❑ Improvement CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-122020178-5302 Report Generated at: 2018-03-06 12:18:28 Project Name: Dr. Elhajar TI NRC&PRF-01-E Page 15 of 16 Project Address: 46-100 Washington Street La Quinta 92253 Calculation Date/Time: 12:18, Tue, Mar 06, 2018 Compliance Scope: ExistingAkeration Input File Name: Elhajar DR. TI-LQ-GLA-17.cibdi6x B. INDOOR CONDITIONED LIGHTING MANDATORY LIGHTING CONTROLS (Adapted from NRCC-LTI-02-E) § 130.1 This Section 1%QPL11940 w 130.1(0) =Manual area controls; §13�lulti Levet §130.1jc% =Auto Shut -Off, §130.1%d% = Mondotoryi)?Anr.• §130.1jej =Demand Responsive C. TAILORED METHOD CONDITIONED LIGHTING POWER ALLOWANCE SUMMARY AND CHECKLIST (Adapted from NRCC-LTI-04-E) § 140.6 General lighting power (see Table D) 0 General lighting power from special function areas (see Table E) NA Additional "use it or lose it" (See Table G) 0 Total watts 0 D. GENERAL LIGHTING POWER (Adapted from NRCC-LTI-04-E) § 140.6-D This Section ' A PP L r ES . "1.k E. GENERAL LIGHTING FROM SPECIAL FUNCTION AREAS (Adapted from NRCC-LTI-04-E) § 140.6(c) 3H Room Number Primary Function Area Illuminance Value (LUX) Room Cavity Ratio (Table G) Allowed LPD Floor Area (ft') Allowed Watts Confirmed Pass Fail NA Nnf-• T -:l-.-.1 AA -.AM f . NA f --.:..I L....Nlw- ....... .. --. _..__-_v., r�-r____._� NA NA NA NA NA ❑ ❑ F. ROOM CAVITY RATIO (Adapted from NRCC-LTI-04-E) Rectangular Spaces Room Number Task/Activity Description Room length (ft) Room Width (ft) Room Cavity Height (ft) RCR Confirmed Pass Fail NA NA NA NA NA NA ❑ ❑ Non -Rectangular Spaces This Section Does Not Apply At- .11 --- 1:...4.1.. A- AI -.._o-..---..1-_ ��--- .-Ar- CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-122020178-5302 Report Generated at: 2018-03-0612:18:28 Project Name: Dr. Elhajar TI NRCC PRF -01-E Page 16 of 16 Project Address: 46-100 Washington Street La Quinta 92253 Calculation Date/Time: 12:18, Tue, Mar 06, 2018 Compliance Scope: ExistingAlteration Input File Name: Elhajar DR. TI-LCI-GLA-17.cibd16,x G. ADDITIONAL"USE IT OR LOSE.IT" (Adapted from NRCC-LTI-04-E) 1. 2. 3. 4. Allowed Watts Confirmed Wall Display p y Combined Floor Display and Task LightingEffects Combined Ornamental and Spedal Lighting Very Valuable Merchandise v T N d 0 0. 0 0 0 Outdoor Controls 5. Wall Display This Section Does Not Apply 6. Floor Display and Task Lighting This Section Does Not Apply 7. Combined Ornamental and Special Effects Lighting This Section Does Not Apply B. Very Valuable Merchandise This Section Does Not Apply H. INDOOR & OUTDOOR LIGHTING ACCEPTANCE TESTS & FORMS (Adapted from NRCC-LTI-01-E and NRCC-LTO-01-E) § 130.4 Declaration of Required Acceptance Certificates (NRCA) —Acceptance Certificates that must be verified in the field. (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). Test Description Indoor . Outdoor Confirmed NRCA-LTI-02-A NRCA-LTI-03-A NRCA-LTI-04-A NRCA-LTO-02-A Equipment. Requiring # of units Testing or Verification Occ Sensors / Auto Time Switch Auto Daylight Demand Responsive Outdoor Controls N N Occupant Sensors 0 ® ❑ El 0 Automatic Time Switch 0 ® 0 El Automatic Daylighting 0 ❑ E Demand Responsive 0 C1 El 1 Outdoor Controls 0 1 11 1 CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-122020178-5302 Report Generated at: 2018-03-0612:18:28 AL • 0 ENVELOPE MANDATORY MEASURES: NONRESIDENTIAL ENV -MM Project Name Date Desert Neurology & Sleep TI 3/6/2018 DESCRIPTION Building Envelope Measures: §110.8(a): Installed insulating material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20 Chapter 4, Article 3. §110.8(c): All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. §110.8(g): Heated slab floors shall be insulated according to the requirements in Table 110.8-A. §110.7(a): All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. Manufactured fenestration products and exterior doors shall have air infiltration rates not exceeding 0.3 cfm/ft.2 of §110.6(a): window area, 0.3 cfm/ft.2 of door area for residential doors, 0.3 cfm/ft.2 of door area for nonresidential single doors (swingingand sliding), and 1.0 cfm/ft.2 for nonresidential double doors (swinging). §110.6(a): Fenestration U -factor shall be rated in accordance with NFRC 100, or the applicable default U -factor. §110.6(a) : Fenestration SHGC shall be rated in accordance with NFRC 200, or NFRC 100 for site -built fenestration, or the applicable default SHGC. §110.6(b): Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). The opaque portions of the roof/ceiling that separates conditioned spaces from unconditioned spaces or ambient air shall meet the applicable U -Factor requirements as follows: §120.7(a): Metal Building- The weighted average U -factor of the roof assembly shall not exceed 0.098. Wood Framed and Others- The weighted average U -factor of the roof assembly shall not exceed 0.075. The opaque portions of walls that separate conditioned spaces from unconditioned spaces or ambient air shall meet the applicable U -factor as follows: Metal Building- The weighted average U -factor of the wall assembly shall not exceed 0.113. Metal Framed- The weighted average U -factor of the wall assembly shall not exceed 0.151. Light Mass Walls- A 6 inch or greater Hollow Core Concrete Masonry Unit shall have a U -factor not to exceed 0.440. §120.7(b): Heavy Mass Walls- An 8 inch or greater Hollow Core Concrete Masonry Unit shall have a U -factor not to exceed 0.690. Wood Framed and Others- The weighted average U -factor of the wall assembly shall not exceed 0.110. Spandrel Panels and Opaque Curtain Wall- The weighted average U -factor of the spandrel panels and opaque curtain wall assembly shall not exceed 0.280. Demising Walls-. The opaque portions of framed demising walls shall meet the requirements of Item A or B below: A. Wood framed walls shall be insulated to meet a U -factor not greater than 0.099. B. Metal Framed walls shall be insulated to meet a U -factor not greater than 0.151. The opaque portions of floors and soffits that separate conditioned spaces from unconditioned spaces or ambient air shall meet the applicable U -Factor requirements as follows: §120.7(c): Raised Mass Floors- Shall have a minimum of 3 inches of lightweight concrete over a metal deck or the weighted average U -factor of the floor assembly shall not exceed 0.269. Other Floors -The weighted average U -factor of the floor assembly shall not exceed 0.071. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Desert Neurology & SleepTl Date 3/6/2018 System Name HVAC Floor Area 4,667 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 COIL CFM Total Room Loads 6,844 Return Vented Lighting Return Air Ducts Return Fan Ventilation 700 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 69,000 101,080 7,234 5,121 63,298 Total Out utBtuh 207,000 0 Output Btuh/s ft 44.4 5,054 3,165 Cooling System 0 0 Output per System 71,000 26,329 5,749 700 33,963 Total Output Btuh 213,000 0 5,054 1 137,516 12,983 0 Total Output Tons 17.8 3,165 Total Output Btuh/s ft 45.6 Total Output s ftrron 262.9 103,590 Air System CFM per System 2,400 HVAC EQUIPMENT SELECTION Airflow cfm 7,200 Existing Package units 142,781 53,263 129,287 Airflow cfm/s ft 1.54 Airflow cfmrron 405.6 Outside Air % 9.7% Total Adjusted System Output 142,781 53,263 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 129,287 Outside Air cfm/s ft 0.15 Jan 1 AM Note: values above given at ARI conditions I HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 67 OF Outside Air 700 cfm Supply Fan 7,200 cfm 72 OF 67 OF 84 OF Heating Coil 84 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 80/67°F 80/67°F 61/60°F 0 Outside Air 700 cfm Supply Fan Cooling Coil 62 / 61 OF 7,200 cfm 58.0% ROOM IN 77/66°F 76/66°F U -T- 1 EnergyPro7.2 by EnergySoff User Number: 6712 ID: Page 20 of 21 ZONE •SUMMARY Project..- Neurology & SleepTl 31612018 System Name FloorDesert .. ZONE LOAD ZONAL•• ILI SYSTEM NAME Tenant Improvement . -. • •