Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2015-0115
11111111111111111111 � o, c&t1f 4 78-495 CALLE TAMPICO VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 10/1/2015 Application Number: BSOL2015-0115 Owner: Property Address: 53575 AVENIDA DIAZ KATHLEEN GLADISH APN: 774111015 53575 AVENIDA DIAZ Application Description: G LADIS H/(48) ROOF MOUNTED PANELS (2)INVERTERS MPU 12.48KW LA QUINTA, CA 92253 Property Zoning: -- Application Valuation: $27,580.00 � Applicant: Contractor: SOLARCITY CORPORATION SOLARCITY CORPORATION ) r 3055 CLEARVIEW WAY 3055 CLEARVIEW WAY ti T' Cn ATTN ZOE STEELE ATTN ZOE STEELE SAN MATEO, CA 94402 SAN MATEO, CA 94402 (650)963-5630 Llc. No.: 888104 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 e Busin nd Professions Code, and my License is in full force and effe Li ense C ss: C fi C1 C20 Li No.: 8 8104 D e� Contract OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from U ntractor's State License Law for the following reason (Sec. 7031.5, Business and Pro siom Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: () I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). () I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ve and will maintain a certificate of consent to self -insure for workers' ca I❑ s provided for by Section 3700 of the Labor Code, for the performance rk r hich this permit is issued. e and will maintain workers' compensation insurance, as required by Sec ion 37 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: "Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to becom ub ct.to the workers' compensation laws of California, and agree that, If oul beep a subject to the workers' compensation provisions of ction 3 of t e abor ode, I shall forthwith Date: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION ERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIESCIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITIO TO HE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 37 THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result ofthis application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and sta a s Ito building construction, and hereby authorize representatives ofth to e t r up o the abovq-megtloneAp{operty for inspection purposes. Date: 1 l 1 I 1 l l i Iv ! Signature (Applicant or DESCRIPTION FINANCIALINFORMATION ACCOUNT a. QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD B1 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - MISC EQUIPMENT 101-0000-42403 0 $48.34 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - MISC EQUIPMENT PC 101-0000-42600 0 $48.34 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for ELECTRICAL: $145.02 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:• 0• Description: GLADISH/(48)ROOF MOUNTED PANELS (2)INVERTERS MPU 12.48KW Type: SOLAR Subtype: Status: APPROVED Applied: 7/28/2015 SKH Approved: 9/30/2015 JFU Parcel No: 774111015 Site Address: 53575 AVENIDA DIAZ LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA AT VALE LA QUINTA Block: 192 Lot: 3 Issued: UNIT 19 NOTES Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $27,580.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 E-MAIL Details: 12.48 kW SOLAR ARRAY - (48) 260W KYOCERA KU2606XPA PANELS W/ (1) ABB PVI-6000-OUTD-US-Z-A INVERTER & (1) ABB PVI-4.2- OUTD-S-US-Z-A INVERTER + MAIN SERVICE PANEL UPGRADE TO 225A + 125A SUBPANEL [864SF] 2013 CALIFORNIA ELECTRICAL CODE. I Applied to Approved Printed: Thursday, October 01, 2015 8:41:33 AM 1 of 3 sys Tr: nns CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTIFIED ELENA W/ SOLAR CITY THAT PLAN REVIEW WAS E-MAIL JAKE FUSON 8/4/2015 8/4/2015 COMPLETE AND REVISIONS WERE REQUIRED. SENT REDLINES AND CORRECTION LIST VIA EMAIL. DISCUSSED 1ST REVIEW CORRECTIONS WITH SOLAR CITY E-MAIL JAKE FUSON 8/7/2015 8/7/2015 DESIGNER BRYAN BLONCHARD. SEE EMAIL CORRESPONDENCE IN ATTACHMENTS. PLAN CHECK PICKED UP STEPHANIE KHATAMI 9/18/2015 9/18/2015 PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 7/28/2015 7/28/2015 RECEIVED PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 9/22/2015 9/22/2015 RECEIVED CONDITIONS Printed: Thursday, October 01, 2015 8:41:33 AM 1 of 3 sys Tr: nns INSPECTIONS Printed: Thursday, October 01, 2015 8:41:33 AM 2 of 3 CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 CONTRACTOR SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 OWNER KATHLEEN GLADISH 53575 AVENIDA DIAZ LA QUINTA CA 92253 FINANCIAL INFORMATION CLTD DESCRIPTION ACCOUNT QTY AMOUNTPAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $2.00 $0.00 BSA: PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $0.00 FIRST 20 PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC PV SYSTEM - MISC 101-0000-42403 0 $48.34 $0.00 EQUIPMENT PV SYSTEM - MISC 101-0000-42600 0 $48.34 $0.00 EQUIPMENT PC Total Paid for ELECTRICAL: $145.02 $0.00 PERMIT ISSUANCE 101-0000-42404 1 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:$0.00 INSPECTIONS Printed: Thursday, October 01, 2015 8:41:33 AM 2 of 3 REVIEW TYPE REVIEWER SENT DATE DUE DATE DATE STATUS REMARKS I NUI ES NON-STRUCTURAL - JAKE FUSON 7/28/2015 8/4/2015 8/4/2015 REVISIONS REQUIRED SEE 1ST REVIEW CORRECTIONS AND REDLINES. 1 WK 8/4/2015 JAKE FUSON 1ST REVIEW REVIEW 0 2ND BLDG NS (1 CORRECTIONS CORRECTIONS.pdf JAKE FUSON 9/22/2015 9/29/2015 9/30/2015 APPROVED 8/4/2015 JAKE FUSON WK) 0 Printed: Thursday, October 01, 2015 8:41:33 AM 3 of 3 (07#?wlYSTE:MS PATHNAME SUBDIR ETRAKIT ENABLED BOND INFORMATION Attachment Type CREATED OWNER ATTACHMENTS DESCRIPTION: BSOL2015-0115 -1ST DOC 8/4/2015 JAKE FUSON 1ST REVIEW REVIEW 0 CORRECTIONS CORRECTIONS.pdf BSOL2015-0115 - 1ST DOC 8/4/2015 JAKE FUSON 1ST REVIEW REDLINES 0 REVIEW REDLINES.pdf EMAIL BSOL2015-0115 - EMAIL CORRESPONDENCE CORRESPONDENCE DOC 8/7/2015 JAKE FUSON 0 WITH DESIGNER -1ST WITH DESIGNER - 1ST REVIEW REVIEW.pdf Printed: Thursday, October 01, 2015 8:41:33 AM 3 of 3 (07#?wlYSTE:MS 1'{A:1 I5 i 12,'. 1'116 fit' b �1® APPLICANT: DO NOT WRITE BELOW THIS LINE City of La Quinta Building 8r Safety Division P.O. Box 1504,78-495 Calle Tampico La.Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Recd TRACICi11TG PERMU FEES Owner's Name: Addrmebb 5� ilcs. City, ST, Zip: La Quinta, CA it City Teiepbone: Clearview Way 1 PrgjeetDescription: roof mount7solarels In Mateo, CA, 94402 2inverter(s) 638-1028 City Lie. #: 8104 ,nw. Vtv List A LZ 'erson: ElenaLoya Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo sq. Ft.: =#Stllill: # Units: ntact Person: (442)256-1134 Estimated Value of Project '1 ,c APPLICANT: DO NOT WRITE BELOW THIS LINE Req'd Recd TRACICi11TG PERMU FEES Plan Check submitted Item Amount ilcs. Reviewed, ready for corrections 8 Plan Check Deposit Called Contact Person rz A4 At'( L— Plan Check Balance Planspicked up Construction Lou Plans resubmitted Mechanical 21' Review, ready for correction �b51t ro Electrical List Called Contact PersonEMA-1 L, 4 Plumbing Plans picked up S.M.I. Val Plans resubmitted Grading Review; ready for correctionsfissue. Developer Impact Fee oval Called Contact Person A.I.P.P. r Date of permit issue Toial Permit Fees ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES -, -, T% A AMPERE 1. THIS SYSTEM IS GRID—INTER11ED VIA A ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. ELECTRICAL, PLUMBING, ENERGY, AND GREEN CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING BUILDING CODES AND THE LA QUINTA MUNICIPAL DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN CODE EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING CITY OF QUINTA EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE BUILDING & SAFETY DEPT. GALV GALVANIZED GROUNDING ELECTRODE CONDUCTOR HAZARDS.EACHEUNGROUNDEDR ART. 7CONDUCTOR OF THE APPROVED GEC GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY FOR CONSTRUCTION HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL DA 9 �5BY� Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY� NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT VICINITY MAP INDEX W WATT 3R NEMA 3R, RAINTIGHT -' r L - PV1 COVER SHEET qC PV2 SITE PLAN i r PV3 STRUCTURAL VIEWS PV4 STRUCTURAL VIEWS LICENSE GENERAL NOTES - PV5 UPLIFT CALCULATIONS ! / PV6 THREE LINE DIAGRAM CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 ,;� µ _ - PV7 LECTRICAL CALCULATIONS C-10 CALIFORNIA BUILDING CODE AND THE 2013 PV8E LINE DIAGRAM CALIFORNIA RESIDENTIAL CODE. l ' Cutsheeee Attached 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR .amu • �. ,•f ' 1 iI AHJ: La Quints L' IREV &Y DATE COMMENTS s , REV A dNft I DATE COMMENTS ' A 9/15/2015 Added Fuses to DC Strings UTILITY: Imperial Irrigation District i•,F� a ti .7 <�+.y' i.� �' � �'ali. d •'fi ►f' aJ i !<x di x x CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB -9223016 0 0 PREMISE OWNER: y DESCRIPTION: Dom +0� CONTAINED SHALL NOT E USED FOR THE GLADISH, KATHLEEN GLADISH RESIDENCE Bryan Blancip 'N}+ ����� � BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �.�1$ NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 53575 AVENIDA DIAZ 12.48 KW PV ARRAY 0,A PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: LA QUINTA, CA 92253 ORGANIZATION, EXCEPT IN CONNECTION WITH TMK OWNER: 1 THE SALE AND USE OF THE RESPECTIVE (48) KYOCERA # KU2606XPA 7�� MM * 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN /tVAIfV• PAGE NAME: SHEET: RE San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER: 760 574-4278 T:(650) 638-1028 F:(650) 638-1029 Multiple Inverters r COVER SHEET PV 1(888)—SOL—CITY (765-2489) www.solarcity.com UN PV MODULE 5/16" BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG BOLT WITH SEALING WASHER (2-1/2" EMBED, MIN) (E) RAFTER SIDE VIEW OF MP2 NTS MP2 X -SPACING X -CANTILEVER INSTALLATION ORDER NOTES LANDSCAPE 48" 24" I (1) 11 LOCATE RAFTER, MARK HOLE LOCATION, AND DRILL PILOT HOLE. PORTRAIT 48" 20" 53575 AVENIDA DIAZ 12.48 KW PV ARRAY CA 92253A—A� (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. MODULES (3} INSERT FLASHING. ORGANIZATION, EXCEPT THE SALE AND USE OF THE RESPECTIVE (4) PLACE MOUNT. 3055 Clearvlew Way San Mateo, CA 94402 (5) INSTALL LAG BOLT WITH SEALING WASHER, PAGE NAME: (760) 574-4278 STRUCTURAL VIEWS PV 3 a 9/16/2015 (6) INSTALL LEVELING FOOT WITH BOLT & WASHERS. SIDE VIEW OF MP2 NTS MP2 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC PORTRAIT 48" 20" 53575 AVENIDA DIAZ 12.48 KW PV ARRAY CA 92253A—A� TOP CHORD 2X4 @ 24 OC BOT CHORD 2X4 @24" OC ROOF AZI 90 PITCH 18 ARRAY AZI 90 PITCH 18 STORIES: 1 Comp Shingle n SIDE VIEW OF MP1 NTS l H MPJ X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" LANDSCAPE 48" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI 180 PITCH 18 STORIES: 1 ARRAY AZI 180 PITCH 18 Comp Shingle nC SIDE VIEW OF MP3 NTS MP3 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" 4\�1'1r ^ � �'1'[^��r�l}i. MOUNTING SYSTEM: Comp Mount Type C PORTRAIT 48" 20" 53575 AVENIDA DIAZ 12.48 KW PV ARRAY CA 92253A—A� TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI 270 PITCH 18 STORIES: 1 ARRAY AZI 270 PITCH 18 Comp Shingle CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: JB—9223016 0 0 PREMISE OWNER: DESCRIPTION: GLADISH, KATHLEEN GLADISH RESIDENCE DESIGN: Bryan Blanchard 4\�1'1r ^ � �'1'[^��r�l}i. MOUNTING SYSTEM: Comp Mount Type C BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S 53575 AVENIDA DIAZ 12.48 KW PV ARRAY CA 92253A—A� •" JLI L. y MODULES IN CONNECTION WITH LA QUINTA ORGANIZATION, EXCEPT THE SALE AND USE OF THE RESPECTIVE (48) KYOCERA # KU2606XPA 3055 Clearvlew Way San Mateo, CA 94402 SHEET: REN DATE: SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PAGE NAME: (760) 574-4278 STRUCTURAL VIEWS PV 3 a 9/16/2015 T:(650) 636-1028 F:(650) 636-1029 1 (888) -SOL -CITY (765-2489) www.sDlarcity.com INVERTER: MUltIDle Inverters (F r SIDE VIEW OF MP6 NTS MP6 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" LANDSCAPE 48" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI 360 PITCH 18 STORIES: 1 ARRAY AZI 360 PITCH 18 Comp Shingle V�SIDE VIEW OF MP4 NTS MP4 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" �O �_ •; (` �� MOUNTING SYSTEM: Comp Mount Type C PORTRAIT 48" 2011 53575 AVENIDA DIAZ 12.48 KW PV ARRAY TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI 180 PITCH 18 STORIES: 1 ARRAY AZI 180 PITCH 18 Comp Shingle SIDE VIEW OF MPI NTS MP5 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48fT 24" �O �_ •; (` �� MOUNTING SYSTEM: Comp Mount Type C PORTRAIT 48" 20" 53575 AVENIDA DIAZ 12.48 KW PV ARRAY TOP CHORD 2X4 @ 24 OC BOT CHORD 2X4 @24" OC ROOF AZI 360 PITCH 18 STORIES: 1 ARRAY AZI 360 PITCH 18 Comp Shingle CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: JB O O PREMISE OWNER: DESCRIPTION: GLADISH, KATHLEEN GLADISH RESIDENCE DESIGN: Bryan Blanchard �O �_ •; (` �� MOUNTING SYSTEM: Comp Mount Type C BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART OTHERS OUTSIDE THE RECIPIENTS 53575 AVENIDA DIAZ 12.48 KW PV ARRAY �`•ola I p�■ MODULES ORGANIZATION, EXCEPT IN CONNECTION WITH LA QUINTA, CA 92253 r THE SALE AND USE OF THE RESPECTIVE (48) KYOCERA # KU2606XPA 3055 Clearview Way San Mateo, CA 94402 SHEET: REV DATE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PAGE NAME (760) 574-4278 STRUCTURAL VIEWS PV 4 a 9/16/2015 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.adarcity.com 1N1 tR' Muullti le Inverters CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 53575 Avenida Diaz INVERTER AND DC DISCONNECT r � , I I I I I I I INVERTER AND ` I I I ! DC DISCONNECT LJ `J- r-� rJ L, L_ J -------- --------------- I rj r---� I ACL_ J L, DISCONNECT r r -I r, L.___J I I UTILITY rJ ' , I I I SERVICE L J L_J r-------- ----------------- , SOLAR ------------- - SOLAR PHOTOVOLTAIC ARRAY(S) L--------------------- - J PHOTOVOLTAIC BACK—FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB -9223016-00 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. ADB NUMBER: JB -9223016 MOUNTING SYSTEM: ComD Mount Type C KYOCERA # KU2606XPA INVERTER: Multiple Inverters 00 PREMISE OWNER: GLADISH, KATHLEEN 53575 AVENIDA DIAZ LA QUINTA, CA 92253 (760) 574-4278 -- — � I � QUINTA CITY Q s� � — BUILDING & �4s-E EDPT FOR CONS f .;ACTION DATE _ GLADISH RESIDENCE 12.48 KW PV ARRAY PACE NAME: SITE PLAN PLACARD DESIGN: Bryan Blanchard SHEET: REV: DATE: PV 9 a 9/16/2015 ,SolarCity. 3055 Clearvfew Way San Mateo, CA 94402 T:(650) 63B-1026 F:(65O) 636-1029 (888) -SOL -CITY (765-2469) www.solarcity.com Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (INV) Per Code: CEC 690.5(C) Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE-By--If- (AC): ATEBY (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR .1tr�� 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �. San Mateo, CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Label Set � +��' T:(650) 638-1026 F:(650) 636 1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE Ir Soj IC (888)-SOL-CifY(765-2489) www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. itv,.l ";r,SolarCity Z pSolar Next -Level PV Mounting Technology ,�SolarCity ZZepSolar Next -Level PV Mounting Technology .Zep System for composition shingle roofs C6MPA71 � er M AaaMPPti� UL LISTED ON zepsolar,com Ground Zep Lew:liniFoot zrp cl"P^blr W try duty Description Zntedock I , PV mounting solution for composition shingle roofs • Works with all Zep Compatible Modules • Auto bonding UL -listed hardware creates structual and electrical bond • Zep System has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" Specifications • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 Zep System bonding products are UL listed to UL 2703 Engineered for spans up to 72" and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Attachment method UL listed to UL 2582 for Wind Driven Rain This document does not create any express warranty by Zap Solar or about its products or services, Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Components zepsolar.com ILI Comp Mount Part No. 850-1382 Listed to UL 2582 & Mounting Block to UL 2703 Ground Zep Part No. 850-1172 Listed to UL 2703 and ETL listed to UL 467 Interlock Part No. 850-1388 Listed to UL 2703 Array Skirt, Grip, End Caps Part Nos. 500-0113, 850-1421,850-1460, 850-1467 Listed to UL 2703 Leveling Foot Part No. 850-1397 Listed to UL 2703 DC Wire Clip Part No. 850-1448 Listed UL 1565 This document does not create any express warranty by Zap Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats,com, 02 27 15 ZS for Comp Shingle Culsheet Rev 04.pdf Page: 1 of 2 02 27 15 ZS for Comp Shingle Culsheet Rev 04,pdf Page: 2 of 2 Designed for residential and small commercial PV installations, this inverter fills a specific niche in the ABB product line to cater for those installations producing between 5kV/ and 20M This inverter includes dual input section to process two strings with independent MPPT. The high speed and precise MPPT algorithm offers real-time power tracking and energy harvesting. Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. AU I i d The wide input voltage range makes the inverter suitable to low power installations with reduced string size. The transformerless operation offers high performance efficiencies of up to 97.1%. Free remote monitoring capability available with every installation. This enables homeowners to view their energy production and offers installers a proactive and economic way of maintaining and troubleshooting the system. Highlights: - Single phase and split phase output grid connection. — Wide input range for increased stringing flexibility. — The high speed and precise MPPT algorithm offers real time power tracking and improved energy harvesting. — Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions. — Integrated DC disconnect switch in compliance with international Standards (-S Version). Additional highlights: — RS -485 communication interface (for connection to laptop or data logger). — Integrated Arc Fault Detection and Interruption (-A Version). Technical data and types Tvpe code PVI-5000-OUTD-US 0 PVI-6000-OUTD-US IVumpar. of IndepQndonl.MFFT channels ; ...................................... 2 .. ......... _.........��...._.._...........---_•_...-................,.-.,_-_ Madrrium us .oe ower for each rhannel .....L' .. ..................... ......... __ . ............... ...................-'--"-'-.�:.:� 40(1pW" "' '" ........._..,_..._...... Atssplutrs maximum-vo na . IVmaxj•.•-• ......._............... _,.,_,.,_.. _ -.�. -- •._......._................... ,., �_-.�,. fip(7Y .. .;.-... ---.-.....-....-..._..........�.,..... _5tart- T vo..... {Vtitart)................... - ..._......... .. _ ... .......................... .....__�...._...�.�. --..- .... 20QV ad;- ?2aM9i Fullpower MPPT.vullage.range..._._...-..... .. __ 20 530V ........._• ... Ueratin MPPT volts a ran a ........... _.....�..._,.,-. _........ P.... -9 ...................9......_...9._........................... ... .. _..._...-......_. _... ...................•---_........_.."....................,....,.._...._,.,-,..-• .. D. x Vstavk- -.:58i1Y --..._..._._._..- .-..-,.,-............... Maximum currant ---- n .. for bath MPPT in parallel .. ......_. .. .. 3g{j. Mtlxlmum usable currant per channel .. 22A tim er wire.land irg term inalsA ehanriplpa{'m t3+� Pv .... . .............. —,—_--------- ---- vanstor, 2for each than nal Riso and €3knamlc GFpI (raquln s f70atirig al T ra[IuireCT arr[s __Meets UL 1741 /IEEE11 !Li -GI Wristor, 2 IL, - Wits .. "'= . ....... ......._,6:5'9 lajr .Graphic �dl -- r8W,w 16 characters x 2 linea LCD disolav na�rruux iiir�ini�rrrn�•�;Ircnaaoa Ila:1 ......... _.�_-cal m......-....-...-...-...-...".;...._ Wlrad lata! manitvrin (TxRS485 Ind: V5N700 Data:L�.�ar_(�ij._...._• ..... .........................._...... ._..-_...................� .. _. �__.._ ... .. ....... ............... _.--.- PVi-tiE8-E3S•is5_23;2.[opt:S I Wyr-...__.....-,-- 1V I-. -304V -...2.spelVt--2iB34wV ....=- ....2._4_T4VI•,G90/ 4V - ...... ...... -.-...... --------- fiolal vQ hur[Ndil I” - ... - J - a .... _ _ - p 1 p0 R 1 eo_nder eenq 0-100% RH cvnden!o - .---•......... �3? ................ .. pqqq - - .............. for abetter world" ^1911P •-•-..._......-...-_...-..l..l.d..(.... ......... 57-60.5Hz ..._.�4a..._...Ig35QA°'d...._ 284Ay �.. Powe[ Factor _ ..._.... - - - "._,.,......... ..........-"--..._.........................: Total t e mgniC diatartiasa at rated power ..,.�_-;:,_.....-...,.,._... ..,.,,.,-.._..,......?.fl...:........-;:...._...-.._..._...-_...._ _...-_ Contributory fault current' ......--"------ ..,.._.._.. 6- 5 A � r �f -36.5 Ii � �T.. ...3�..•-n-A, ,.AF',�j5.25 Art -.....,.•$. ...�_...._.... .3 .7�••A �I - � --- .................._:.:__...-_,.,....................._�_...-.... 'jrii L41h/10 termlrlr{rkSn IVCK! 7b63P I••-••-•••:•. •.•-. 25.&1.. s.. _,._22.4aA° Tn...�.....!r.l.:..l. 25. 3... '..... �... �... ..1....... i12+�•a r, 25:81A 8 5e •.•iir.�n� .. t3+� Pv .... . .............. —,—_--------- ---- vanstor, 2for each than nal Riso and €3knamlc GFpI (raquln s f70atirig al T ra[IuireCT arr[s __Meets UL 1741 /IEEE11 !Li -GI Wristor, 2 IL, - Wits .. "'= . ....... ......._,6:5'9 lajr .Graphic �dl -- r8W,w 16 characters x 2 linea LCD disolav na�rruux iiir�ini�rrrn�•�;Ircnaaoa Ila:1 ......... _.�_-cal m......-....-...-...-...-...".;...._ Wlrad lata! manitvrin (TxRS485 Ind: V5N700 Data:L�.�ar_(�ij._...._• ..... .........................._...... ._..-_...................� .. _. �__.._ ... .. ....... ............... _.--.- PVi-tiE8-E3S•is5_23;2.[opt:S Envlrrinmental - Ambient air operating temperature range -13"F to +140"F (-25°C to +60°C) `1 t0 +140" -2 `C to •F60 C} +,Wth ..........13-1.1.1-1-1---.1 ...__....... _-- ............................._...... ...... _.—..._.......=........... Am.rtirrt airst"-Wtempar�ture range , ........-...-,.,..•„•_i -'__'-_._-._...-................................_...._......._._-.._,.,..,.......Our atln$ �0-F to +17w° [-10°U is +8D°C}......... -. -40'F to+17& F [-q6`C to +80'Cl.-.... fiolal vQ hur[Ndil I” - ... - J - a .... _ _ - p 1 p0 R 1 eo_nder eenq 0-100% RH cvnden!o ACouSt1Gn41t;T1eftsalep evi3.:._......_...._............ .........-...-...._[__......._...._................,...............(..�:...----•-•._...... Maximum prs irr ellii4tp .wthpul dcralinr e 50 db A r�1 m < 50 ]b A cvl m ..........._._......._......__..._...�._.C.......I...i.. ... .......... ....._.�,� 6560 ft {20M m i 6564 ft f7000 m _.....�_.._.,.......-,.W.L._...- .............................3. _......_.... Power and productivity y '.. Invr+rtea can nppty ttwl much current - Breaker will open - - .............. for abetter world" ^1911P 2 ABB Solar Inverters I Product flyer for PVI-5000/6000-TL-OUTD AU This family of single-phase string The high-speed MPPT offers real - inverters complements the typical time power tracking and improved number of rooftop solar panels energy harvesting. enabling home -owners to get the most The flat efficiency curve ensures high efficient energy harvesting for the size efficiency at all output levels allowing of the property. a consistent and stable performance Absolutq,rnaxlnium VnitC (Vmax] across the entire input voltage and This inverter offers a dual input output power range. section that processes two strings The transformerless operation gives the with independent Multiple Power Point highest efficiency of up to 97,0%. Tracking (MPPT). The wide input voltage range makes This is especially useful for rooftop the inverter suitable to low power installations with two different installations with reduced string size_ orientations from two sub -arrays This rugged outdoor inverter has been oriented in different directions, (For designed to be a completely sealed example: East and West) unit able to withstand the harshest The dual input sections with environmental conditions. independent MPPT enable a more = 11-0 optimal energy harvesting condition, 1 '0'Split- Highlights: - Single phase and split phase output grid connection. - Wide input range for increased stringing flexibility. - The high speed and precise MPPT algorithm offers real time power tracking and improved energy harvesting. - Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions. - Integrated DC disconnect switch in compliance with international Standards (-S Version). Power and productivity A 11 It for abetterworld"" ^190 Additional highlights: - RS -485 communication interface (for connection to laptop or data logger). - Integrated Arc Fault Detection and Interruption (-A Version). Technical data and types -Type code PV:-3,0-01JTD-US PVI-3.6-OUTD-US PVI-3.8-01LITD-US PVI-4.2-OUTD-US fi�S9d7flnicel splBClftcatkSns ". -- � 330U t =� Nominal output power 300OW 3600W w f 3800W 4200W Maximum output power wattage 3000 330D+ 330'! 35biJ j 40)01Ob01i330bIf`L>70{ j A2t)be 42l'10 X64[11 ;-48�7Q'� w i..w w € W. = W W i W. ? .W.. .`N.. _._W ....... i3sted' �d1dAC valta a .t� t zaov 277V 20 = z77V KIWI` 24DV .�.. i ................. I ul side _,.,_.. -.x........_..._......-•----..—........_.2......_......._........_..._ 2 _................... ...,,.� ................ ,Number.nf]npep�d©nt:MPPT.channels�•--- fvlaxim im usable }Sduver fDr eadh Chsnnef --- ..,.,.. • ••. 2Q(70i1V •.•-••..,•_, ----..9000W............-�6V......._.-.QdW.—...—....i._..._..........3000W ... ........... Absolutq,rnaxlnium VnitC (Vmax] chrin a Nurrllw of wire landing terminals er c1W vt¢I . ....... 93:f3%..._.......,.,......L._..._..._.. �79�......_........_._;_.-...,.,_.,,.._9790 i, - ..............•-•--=----..........._.—..._......._.......-....—..._....._......_............_...._......._-.—..-----....—�.�..._....—�.�_... ......... Stait- upvhape ,(Vstart)..............—-,,... `---._........_.............-..._:-:-...._....._....—...._pW,I?i�..52435QYj-•....... -........ - -_ ,530V._.........I 1443Q�1. ............... -- _ ---' ".-.---'-•--- 140 530V .......-.....-...-...—......----- Qperailr?9•MPPTvoltagerang?..,..._...... < 0.6W_.._ _...,.._f7;7xVstart"fi9W(r!3UV}. :' .... ....... _._......... ..... .............. _ H1aXiYlul'ITcurYBnt(1dCiriax�iorhM�F�'-in------•-•-• 20A - 32A 32A i32A 1 1 umble curre,tl per,chanrwl.--•--._.......... 10A —.. -::._............._...1.6A, .�.. i ................. . r:,. •.--�.. _...._.,.,_.......-.:.,.,_..�_ _,.,_.. ..AM1aximum MAximum short clr[:ult L'urrent Ifrr it pE r = 12 SA 20 OA ....-,.,T -—...... _...—.... varistor, 2 (L - L I L,. d1 _ ..... _ 1............" " 20.OA 20, OA • IVlaw m operatlnc� elfdufde without deralEng-I_......_.................".__—�"�_............._...,.�...._...... chrin a Nurrllw of wire landing terminals er c1W vt¢I ,cy- 93:f3%..._.......,.,......L._..._..._.. �79�......_........_._;_.-...,.,_.,,.._9790 i, _ R.-.-.. -•- ........... -......-........._.... .y.....,. ..........._...."__---....,",-..................,.._.,.,..............,.,. .................... - < 0.6W_.._ Tarminal h1dGk,. ressure clamp, AWG10-AW[34. Array wiring tem ination Qutput side [ACl = 11-0 t - 1 '0'Split- 1 1 10f p It- 1 1 1 CSI Sp)T• ~1(-11 Grid connection type " " 2Vy-_ `:L44- t�1W 1 2w •.•,••. w C313W. -"211- _: 21W _ _ 2y0 _ '2,14: ... 183-- _QI 2W•,,,I_ 2W ..i.. ,. _ 211- 2,1 -.! 18�[. - 0i3W 211--'...244- Adjustable voltage range (Venin-Vmax) (V) :183- 22 V 264V 304V 228V 264V 3g4V 72 26AV �: 304V 228V 26AV 344V Grid hequancx_.�.�::.:.:......,,.- - .-_..._.....:. [VHS ..._.... -.... . _ _._..._........... Adi...... a ri[i[reyueric rerx)[f _ —....;...t.4....i Maximum current (L,�n:�.) Axes[....:% _ 1rr5 {.:] 1�. .,...}5O ....S5.0.. � S7.6L1.5Hx --_ ....1G.IS _: A A 18;G'......�6.b..�...21�� 1 ?a. 261 ....._......._......._.............��.,T,.,��.,_�.�.... _�-�--....,....... Power factor ! �i,A a._).. .�ru.-........._ r ...'....� > 17;995 gr ..... .. Tntal harmonic distortion at rated power - Terminal <2% A4V.GT0 AWG4 Grid wfrina termtrratipn type bl4yk, I'ressuieaam _..._.........._._�. ._...,..,r...........,... tection type,••-••.,•••-.. ..._...-_..._...-..........._.._Varisi-6 fvr cacti Channel fault detection pfA stat[ -VP Rlxa and Dynamic GFDI (rnulrss floating arra! ndevices -- 3fa[:t an ..! Maets UL 1741/IEEE1547. req�uir"nt. -...._......_..,-..... ........ �. _._.... tectihn !ype ....-,.,T -—...... _...—.... varistor, 2 (L - L I L,. d1 _ ..... _ 1............" " :P0 Ralin '-•---...._.............�{ 20l� ..f2d/iti-::16A,�„ ; 25�w..2gAmer Zi>Ao..� 2uAl,,,. A,,..n Q • IVlaw m operatlnc� elfdufde without deralEng-I_......_.................".__—�"�_............._...,.�...._...... �..._..---•,............-.-_�.-.-.---. . -.....__,, ,cy- 93:f3%..._.......,.,......L._..._..._.. �79�......_........_._;_.-...,.,_.,,.._9790 i, --.................--...-.........._ 96 mance < 0.6W_.._ J""""• 1 Uzer-interface�.�_,.,_......._,.,�.�,., 16..characters x 2 lines LGL] pt ..........._.__,-,.,._.........,.. #P ......- ...._................................ _.......... _. ................................ ........._...—.;.... ....... Romote monitoring (1xRS485 incl.) VSN700 Data r (vRt•} Eri l ronmer lel -- Amfolantalroperating.temperaturerange............_..._...--:,..........-,.,- •13°F to +140`F Vi d0r8 ahova 122'F 54`C »..-...-.._._.............._............ 1.u^_8.... 0 ......._,.............,.._.. _,.,T�...�...�- b0.°F_t¢s +1 i 'F(-.Ap°G..... j Am lent air storage tem erature.range -.... -...... r-........--- ..............._..........._...-...... relative humidO. 0.1DD96 R!i condensing —._ ........... . ....._......_-- ........:.............— ACdpmustic noise emission level < 50d.6' 0 tlb {A) Aim _••••.••_,-,_•,..•••. • IVlaw m operatlnc� elfdufde without deralEng-I_......_.................".__—�"�_............._...,.�...._...... �..._..---•,............-.-_�.-.-.---. . -.....__,, 1. Capability enabled at nominal AC voltaic And W01 sufficient DC power available, 2 ABB Solar Inverters I Product flyer for PVI-3.0/3,6/3,8/4,2-TL-0UTD KYOCERa CUTTING EDGE TECHNOLOGY As a pioneer with four decades of experience in the development of photovoltaic systems, Kyocera drives the market as a leading provider of PV products. We demonstrate our Kaizen philosophy, or commitment to continuous improvement, by setting the industry standard in the innovation of best -in -class solar energy equipment. QUALITY BUILT IN • UV -stabilized, anodized aluminum frame in black • Supported by major mounting structure manufacturers • Easily accessible grounding points on all four corners for fast installation • Proven junction box technology with 12 AWG PV wire works with transformerless inverters • Amphenol H4-UTX locking plug-in connectors provide safe, quick connections PROVEN RELIABILITY • Kyocera modules confirmed by the Desert Knowledge Australia Solar Centre to have the highest average output of any crystalline module • First module manufacturer in the world to pass long- term sequential testing performed by TUV Rheinland • Only module manufacturer to achieve the rank of "Performance Leader" in all six categories of GTM Research's 2014 PV Module Reliability Scorecard CERTIFICATIONS • L11-1 703 Certified and Registered, UL Module Fire Performance: Type 2, CEC • NEC 2008 Compliant, IEC 6121561730, and ISO 14001 �pMPRT us •o7ara KU -60 1000V Z Series KU255-6XPA KU260-6XPA ELECTRICAL SPECIFICATIONS P_ 255 260 w Vmp 30.8 31.0 V 1.9 8.28 8.39 A Vm 38.0 38.3 V 1. 8.83 9.09 A Pral- +5)-0 +5/-0 % Operating TemperatureNominal Cell NOCT=800 ambient T. 45 45 °C P_ 183 187 w V.. 27.7 27.9 V 1, 6.61 6.71 A V. 34.8 35.1 V IK 7.15 7.36 A PIC 228.3 232.9 w P_ -0.45 -0.45 %/°C V.P -0.48 -0.48 %/°C Iry 0.02 0.02 %J°C V_ -0.36 -0.36 %/°C 1. 0.06 0.06 %/°C Operating Temp -40 to +90 -40 to +90 °C System Design Series Fuse Rating 15A Maximum DC System Voltage (UL) 1000V Hailstone Impact t in (25mm) @ 51 mp (23m/s) 'Subject to simulator measurement uncertainty of +l- 3$ KYOCERA reserves the right to modify these specifications without notice NEC 2008 COMPLIANT wncylrvc: Rears W+ cuw UL 1703 USTED L.,In nNllual in IIs emit, vrral err Italy illy g,IM Fimg. B prpx pP 062614 hg Ky az 5stir Innlin•• KU -60 1000V Series MODULE CHARACTERISTICS Cells per module: 60 (6 x 10) Dimensions 65.43ini38.98ini1.57in lengfhlgw'dtiyheight (1662mm/990mmi40mm) Weight: 47AIbs (21.5kg) PACKAGING SPECIFICATIONS Modules per pallet 20 Pallets per 53' container: 36 Pallet box dimensions 66ini40ini43in lenglWwA t0eight (1675mmi1005mmi1055mm) Pallet box weight: 1060lbs (480kg) Grounding N°le Slatted IMmling H.I. 0,16- (4mn) R05 -t0, 47" Omar 2m) FRAWE:CROSS SECTION DIAGRAM A n - r, n-ps.n I ,.esnra.I LGRG/SNORT SIVE STABILIZER BM OUR VALUED PARTNER � ~ ; � wR / \ � , _ =m3.05 m i� am a ,m ,_ . m m ■ ' � R ■ ` ® m » 0| -■ ' = m 7stl -® � \ � / \ � � | \ � |R 0000 ¥ G . w � � �•� � ■ ®. ZepSolar ZS Comp'" 1 Grounding and Bonding This document describes the mechanics of how the electrical bonding is accomplished between the UL Listed hardware components used in Zep Solar's ZS Camp mounting solution for composition shingle roofs. Zep Compatible'" systems do not require running copper conductors to each module. The act of physically installing each component simultaneously establishes an electrical bond, as described in the following pages. Document 800-1478-001 Rev A www.zepsotar.com 02013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice All rights reserved. PAG E: 1 of 5 Date Last Exported: June 25, 20134:45 PM 10 ZepSolar Interlock r Key Side Bonding Cutting "tooth" Key side in closed position Cutting "tooth' Tongue Side Bonding Tongue side in closed position Cutting "teeth" 2S COMP I rPnimnmr ANn PtnKInINr Interlock Zep Tongue side Side view Interlock Module Bonding locations on Key side Forced interference during rotation of Interlock Zep causes teeth to cut through anodizalion on module frame, resulting in robust and UL certified bonding path Module Q I Forced interference between mating parts from module Bonding location on rock -in motion cuts into module frame, removing Tongue side anodization and resulting in robust and UL certified bonding path Document 800-1478-001 Rev A www.zepsolar.com PAGE: 205 © 2013/EN Zep Solar, Inc Zep Solar reserves the right to make specifications chnages without any prior notice- All rights reserved. Date Last Exported: June 25, 2013 4:45 PM 0 ZepSolar Interlock, continued mftft Part No 850-13BB UL Listed to UL 2703 ZS COMP I GROUNDING AND BONDING Bonding Path - Key and Tongue The Interlock hoods modules on all sides to create ahyper- ■ Leveling Foot bonded array where every module is structurally and electrically bonded to the surrounding modules, o!mm Interlock Module Tongue side Bonding path ■ Banding path Interlock �r•. Fjf k 1 Key side Bonding Path - Array Document 800-1478-001 Rev A www.zepsoLar.com PAGE: M5 5 Co 2013/EN Zep Solar, Inc Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25, 2013 4:45 PM 0 Zep Solar Leveling Foot Part No, 850-1397 UL Listed to UL 2703 ZS COMP I GROUNDING AND BONDING Tongue side .0— - — - - — - 4. Key side The Leveling Foot top portion (the Rockit( has a stainless steel spring clip that hands to the adjacent module frame on both Key and Tongue sides Leveling Foot - Bonding With Module Frame Spring clip Key side inserts into Zep Groove (rock -in) Module in next row drops in on the Tongue side Bonding Path - North and South Modules E © ■ Leveling Foot h o!mm Interlock Bonding path ■ Banding path M k M y 10, 101 Ilk. Down -roof 1 Down -roof Document 800-1478-001 Rev A www.zepsoLar.com PAGE: M5 5 Co 2013/EN Zep Solar, Inc Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25, 2013 4:45 PM 0 Zep Solar Leveling Foot Part No, 850-1397 UL Listed to UL 2703 ZS COMP I GROUNDING AND BONDING Tongue side .0— - — - - — - 4. Key side The Leveling Foot top portion (the Rockit( has a stainless steel spring clip that hands to the adjacent module frame on both Key and Tongue sides Leveling Foot - Bonding With Module Frame Spring clip Key side inserts into Zep Groove (rock -in) Module in next row drops in on the Tongue side Bonding Path - North and South Modules E © ■ Leveling Foot h . ■ Banding path M k M y Down -roof Bonding location on Key side imp- Bonding location on Module rotation during drop-in creates forced Tongue side interference between Zep Groove and spring clip, cutting into module frame, removing anodization and resulting in robust and UL certi0ed banding path Document 800 -1478 -ODI Rev A www.zepsolar.com PAGE: 4 of 5 © 2013/EN Zep Solar, Inc Zep Solar reserves the right to make specifications chnages without any prior notice All rights reserved Date Last Exported: June 25, 20134:45 PM 0. ZepSolar Ground Zep Setscrew Part No. 850-1172 UL Listed to UL 467 and UL 2703 Ground Zep Installation Key side Ground wire channel ZS COMP I GROUNDING AND BONDING The Ground Zep provides a single point of connection for the Equipment Grounding Conductor (EGC) from the array to a building ground 7 W _ - -- 1, MU I Insert Ground Zep into Zep Groove of module frame. Use the Flat Too to rotate the Ground Zep 90 degrees, so thatset screw Insert copper EGC into ground wire on army perimeter is pointing straight up channel. Tighten setscrew using torque values shown in the ZS Comp Installa- tion Manual. Bonding Path - Array to Ground tom} Ground Zep �— Equipment Ground Conductor Bonding path 1 Down -roof Document 800-1478-001 Rev A www.zepsolarcom 02013/EN Zep Solar,Inc. Zep Solar reserves the right to make specifications chnages without any prior notice All rights reserved. PAGE: 50f5 Date Last Exported: June 25, 20134:45 PM SolarCity Standard Box 4J The SolarCity Standard Box 4J is a 4 -String unfused Junction Box. The box is highly configurable and adaptable using the (4) jumper blocks included in each box. A factory installed cordgrip enhances installer productivity. SolarCity, October 2013 • Manufactured to meet UL 1741 Standards. • Non -Metallic, Corrosion Resistant NEMA 4X Enclosure. • Factory -Installed Cordgrip Enhances Installation Speed. • Break-Thru Skinned -Over Glands on Cordgrip Provide Weathertight Seal for All Configurations. • Easily Configurable Terminal Blocks Permit Adaptation to Site -Specific Stringing Needs. Technical Data / Specifications A Voltage Rating [VDC] : 600V B Maximum DC Current [A]: 57A C Maximum Continuous Current [A]: 42A ❑ Maximum Voltage [VDC]: 600V E Wire Size Range [AWG]: #6 to #14 F Enclosure Rating: NEMA 4X G Operating Temperature Range [°C]: -40 to 50 H Typical Overall Dimensions [in]: 8"x6"x4" NOTICE OF COMPLETION AND AUTHORIZATION TO APPLY THE UL MARK 12/21/2013 Solarcity Corp Alex Yang 3055 Clearview Way San Mateo Ca 94402-3709, Us Our Reference: E318537, Volume 1 Project Number 4786083586 Your Reference: A.Yang 1017 Project Scope: Investigation of Photovoltaic (PV) System Combiner Box, model "SolarCity Standard Box 4C" and Photovoltaic (PV) System Transition Box, model "SolarCity Standard Box 4J" to UL 1741 Standard. Dear Alex Yang: Congratulations! UL`s investigation of your products) has been completed under the above Reference Number and the product was determined to comply with the applicable requirements This letter temporarily supplements the UL Follow -Up Services Procedure and serves as authorization to apply [lie UL Mark at authorized factories under UL's Follow -Up Service Program. To provide your manufacturer($) with the- intended authorization to use the UL Mark, you must send a cepy of this notice to each manufacturing local ion currently authorized under E318537, Volume i and including any special ins[ructiens as indica fed in the addendum to this letter. Records in the Follow -Up Services Procedure covering the product are now being prepared and will be sent in the near future. Until then, this letter authorizes application of the UL Mark for 90 days from the date indicated above. Additional requirements related to your responsibilities as the Applicant can be found in the document "Applicant responsibilities related to Early Authorizailons" that can be found at the following web -site: h :t .ul.comlEARes 'iilles Any information and documentation provided to you involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. We are excited you are noW able to apply the UL Mark to your products and appreciate your business. Feel free to contact me or any of our Customer Service representatives if you have any questions. Very truly yours, Jon Adonay 408-754-6630 Engineering Associate Lead Jon.Adonay@ul.com NBKD9C5-90BA67 Reviewed by: William R. Carney 847/664-1088 Chief Engineer Director I VVilliam.R.Camey@ul.com This is an electronically generated letter Signatures are not required for this document to be valid. Page 1 of 1