BRES2018-011978-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type/Subtype:
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation: .
Applicant:
ANTON MARINKOVICH
5S0 S OLEANDER RD
PALM SPRINGS, CA 92264
Liht U VOICE (760) 777-7125
FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 5/29/2018
BUILDING RESIDENTIAL/ADDITION E Owner:
BRES2018-0119 WILLIAM SLIFER
78023 SAN TIMOTEO STST I� 5701 E STANFORD DR
646160003 4J ENGLEWOOD, CO 92253
SLIFER / 371SF ADDITION AN 14 EMODEL 29�$
$250,000.00
�Q��Ni FpQaiMN�
Contractor:
MONARCH HOMES DESERT DIVISION INC DBA DA
49-950 JEFFERSON ST #130-134
INDIO, CA 92201
(760)413-8863
Llc. No.: 457228
LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter I hereby affirm under penalty of perjury one of the following declarations:
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, _ I have and will maintain a certificate of consent to self -insure for workers'
and my License is in full force and effect. compensation, as provided for by Section 3700 of the Labor Code, for the performance
License Class: B License No.: 457228 of the work for which this permit is issued.
q C� / .
/—
1 have and will maintain workers' compensation insurance, as required by
Date: -9- °Z I ' ( O Contractg11 �j �/
f
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
OWNER -BUILDER DEQARATION
Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 9045509
1 hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
_ I certify that in the performance of the work for which this permit is issued, I
city or county that requires a permit to construct, alter, improve, demolish, or repair
shall not employ any person in any manner so as to become subject to the workers'
any structure, prior to its issuance, also requires the applicant for the permit to file a
compensation laws of California, and agree that, if I should become subject to the
signed statement that he or she is licensed pursuant to the provisions of the
workers' compensation provisions of Section 3700 of the I shall forthwith
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
7Laboe,
comply with those provisions.
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
Date: �' Applican . /
permit subjects the applicant to a civil penalty of not more than five hundred dollars
�
($500).:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
(_) I, as owner of the property, or my employees with wages as their sole
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
compensation, will do the work, and the structure is not intended or offered for sale.
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
apply to an owner of property who builds or improves thereon, and who does the work
INTEREST, AND ATTORNEY'S FEES.
himself or herself through his or her own employees,: provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
APPLICANT ACKNOWLEDGEMENT
within one year of completion, the owner -builder will have the burden of proving that
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
he or she did not build or improve for the purpose of sale.).
the conditions and restrictions set forth on this application.
(_) I, as,owner of the property, am exclusively contracting with licensed contractors
1. Each person upon .whose behalf this application is made, each person at whose
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
request and for whose benefit work is performed under or pursuant to any permit
State License Law does not apply to an owner of property who builds or improves
issued as a result of this application , the owner, and the applicant,. each agrees to, and
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
shall defend, indemnify and hold harmless the City of La Ctuinta, its officers, agents, and
the Contractors' State License Law.).
employees for any act or omission related to the work being performed under or
( ) I am exempt under Sec. - B.&P.C. for this reason
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
Date: Owner:
work for 180 days will subject permit to cancellation.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction,. and hereby authorize representatives of this city to enter upon the
above -mentioned property for inspection purposes.
Date: Signature (Applicant or A0 Qn4
Date: 5/29/2018
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
Applicant:
ANTON MARINKOVICH
550 S OLEANDER RD
PALM SPRINGS, CA 92264
BRES2018-0119
78023 SAN TIMOTEO ST ST
646160003
SLIFER / 371SF ADDITION AND INTERIOR REMODEL
$250,000.00
Owner:
WILLIAM SLIFER
5701 E STANFORD DR
ENGLEWOOD, CO 92253
Contractor:
MONARCH HOMES DESERT DIVISION INC DBA DA
49-950 JEFFERSON ST #130-134
INDIO, CA 92201
(760)413-8863
Llc. No.: 457228
Detail: SLIFER / 371 SF ADDITION + INTERIOR REMODEL TO EXISTING 4,096 S.F. HOME, RESULTING IN A TOTAL OF 4,467 SF. NEW SERVICE ROOM 278 SF AND
SITTING ROOM 93 SF UNDER EXISTING PATIO ROOF. REVISE CURRENT LAYOUT OF INTERIOR WALLS AND ELECTRICAL TO ACCOMMODATE NEW FLOOR
PLAN. REPLACE [81 WINDOWS, RELOCATE WATER HEATER AND HVAC. INSTALL NEW FIREPLACE AT LIVING ROOM.[ENGINEERED) SMOKE/CO ALARMS TO BE
FIELD VERIFY. THIS PERMIT DOES NOT INCLUDE THE REPLACEMENT OF ELECTRICAL SERVICE PANEL. 2016 CALIFORNIA BUILDING CODES.
1 INFORMATION
FINANCIAL
DESCRIPTION ACCOUNT
CITY
AMOUNT
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400
0
. $67.10
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$18.72 '
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ADDITION, FIRST 100 SF
101-0000-42400
0
$131.07
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$184.13
Total Paid for ADDITION: $401.02
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ART IN PUBLIC PLACES.-, RESIDENTIAL
270-0000-43201
0
$125.00
Total Paid for ART IN PUBLIC PLACES - AIPP: $125.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HOURLY CHARGE - YES HISTORIC
101-0000-42600
0
$10.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HOURLY CHARGE -YES STRUCTURAL PLAN REVIEW ENGINEER
101-0000-42600
1 1.5
1 $142.50
Total Paid for BLDG CITY STAFF - PER HOUR: $152.50
DESCRIPTION
ACCOUNT
CITY
AMOUNT .
BSAS SB1473 FEE
101-0000-20306
0
$10.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $10.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20
101-0000-42403
0
$26.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20 PC
101-0000-42600
0
1$26.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES/FIXTURES, ADDITIONAL
101-0000-42403
0
$345.80
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES/FIXTURES, ADDITIONAL PC
101-0000-42600
0
$86.45
Total Paid for ELECTRICAL: $484.27
DESCRIPTION
ACCOUNT
CITY
AMOUNT '
FURNACE
101-0000-42402
0
$39.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FURNACE PC
101-0000-42600
0
$26.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN
101-0000-42402
0
$104.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN PC
101-0000-42600
0
$41.60
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WALL HEATER
101-0000-42402
0
$26.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WALL HEATER PC
101-0000-42600
0
$13.00
Total Paid for MECHANICAL: $249.63
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PARTITION
101-0000-42400
0
$78.02
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PARTITION PC
101-0000-42600
0
$143.56
Total Paid for PARTITION: $221.58
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PLAN CHECK DEPOSIT-ADDITION/REMODEL
101-0000-42600
1
7 $250.00
Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $250.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$169.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$169.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER HEATER CHANGEOUT
101-0000-42401
0
$13.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER HEATER CHANGEOUT PC
101-0000-42600
0
$7.80
Total Paid for PLUMBING FEES: $358.80
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RECORDS MANAGEMENT FEE - MAJOR
101-0000-42416
0
$20.00
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $20.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$32.50
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $32.50
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DOOR/WINDOW, RETRO/REPAIR, FIRST
101-0000-42400
0
.$6S.54
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DOOR/WINDOW, RETRO/REPAIR, FIRST 7 PC
101-0000-42600
0
$63.98
Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $129.52
tevQa (ePERMIT#
EM flh,DESERT 'I—(,(/
PLAN LOCATION:
rJ�
Project Address: -%
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #: CoS p . �3G Flo
SUI %tea-�lJi�7�itJ-
.mil
Sia1V l �UT�2�
�
Applicant Name: AA17',7j/,/
Address: 5750 S. O
City, ST, Zip: P&61
Telephone: S-
Email: g���h s fj^�G , .��
Valuation of Project $ o,-e,O
Contractor Name:
New SFD Construction:
Address:
Conditioned Space
1:5 7 % SF
City, St, Zip
Garage
SF
Telephone:
Patio/Porch
SF
Email:
Fire Sprinklers
SF
State UcAlgiJ-10; .. City Bus Lic:
Arch/Eng Name:AX-AWle- GAGA
Construction Type: /LGNW1i��p Occupancy:�`3/(J/
Address: . -r-O . S - G
Grading:
City, St, Zip PjgLm 5Piz1`v
Telephone: 7 $� / .
Bedrooms:
Stories:
# Units:
Email: 11 S lip. Gr1yYJ
State Lic:G`19� City Bus Lic:�`l%y�0�2
SF
Property Owner's Name: AIGL G SG/
New Commercia / Tenan mprovements:
Address: 7b _0jz
Total Building SF
City; ST, Zip G� Z
Construction Type: Occupancy:
Telephone: 363
Email: S�u/S�i G�OI cG�
78495 CALLE TAMPICO
LA CLU1NTA, CA 92253
760-777-7000
Date: 5/25/2018
No.: 18-00971-1
Owner: William Slifer
Address: 78-023 Timoteo St
City: La Quinta
Type: Residential Addition < 500 Sq ft
Lot # Street No.
78-023
Comments:
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
La Quinta, CA 92253
(760)771-8515
Street Name
San Timoteo St
JN�Ft£O.
Q2y 6
vl BEalau'FIn OUid£s r.
e- �iruo�wE y
r6 PCOA DESERT w
� tAISTAA
o rNMo 1'`-0
Email:
Jurisdiction: La Quinta
Tract #:
Sq. Feet APN Permit No.
371 646-160-003
RECEIVED
MAY 2 5 20%
CITY OF lA QUWT;a
DESIGN AND DEVE? O ':' . - WMW
At the present time, the Desert Sands Unified School District does not:collect fees on garages/carports, covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement.
mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less.
Exempt
This certifies that school facility fens imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 371 S.F. or $0.00 have been paid for the property listed above and that building permits
and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Fees Paid By: Exempt/Greg Bonano Check No.:
Bank Name/Recipient of Certificate Telephone: 949-283-0365
Funding: Exempt
By Scott L. Bailey
Superintendent
Fee Collected/ Exempted by: Arianne Catano Certificate. -Fees Dua: $0.00
Original Paymeh(s) Rec'sd: $0.00
New Payment Rec'A: $0.00
Qve�/Under: $O..00 J
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on. which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
From: charlle coulter charlie@bunkerbrokers.com
Subject: Remodel 78023 San Timoteo La Quinta
Date: March 6, 2018 at 3:40 PM
To: Slifer, Carol sewsli@aol.com
Cc: Marinkovich Anton anton@stracts.com
Mr. & Mrs. Slifer,
This email is to confirm that I have reviewed your plans for your project. Based on those'
plans I approve your request on behalf of the La Quinta Golf Estate HOA.
Chairman of the Architectural Committee.
Charlie Coulter
Coulter & Associates, Inc.
www.LaQuintaCountryClubs.com
760.777.8822
1! o Virus -free. www.avast.com
RECEIVED
MAY 10 2018
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
Building Permit Number:
Project Description: Rm Addition & Remodel
Exempt: ❑
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
Plan Submittal Date
Job Site Address
Owner's Name
Number, Street, or PO Box
City, State, Postal Code
Owner's Phone Number
Owner's E-Mail Address
Project Manager's Name
Project Managers Phone Number
Project Manager's E-mail Address
Builder / Contractor
Number, Street or PO Box
City, State, Postal Code
4/27/2018
78025 San Timoteo
Carol & Bones Slifer
78025 San Timoteo
La Quinta, CA. 92253
760-564-4106
Greg Bonano
949-283-0365
greobonanoL@omail.com
David Jacobsen Building Co.
49950 Jefferson St #130-134
Indio, CA. 92201
Project Square Footage Approx. 314sq ft (addition)/2,000sq ft (remodel)
City Approval By Renado Gouldlock-DEC/Burrtec Waste 2 ,
Date of City Approval
Materials To Be Discarded:
Product
Trash
Asphalt
Brick/Block
Cardboard
Commingled
Concrete
Drywall
Donated / Reuse''
*Describe Items
Tons
Not recyclable Product Tons
Recyclable Masonry (broken) 0.00 Recyclable
Recyclable Plaster 1.10 Recyclable
Recyclable Scrap Metal 0.00 Recyclable
Recyclable Tile (floor) 0.10 Recyclable
Recyclable Tile (roof} 0.13 Recyclable
Recyclable Wood 1.70 Recyclable
Recyclable Landscape Debris 0.00 Recyclable
4.00
0.00
0.00
0.00
0.00
4.00
0.50
0.0-01
Totals: Recycle Trash Projected Diversion:
7.51 4.0E-6-5.3-19/0
I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is
diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or
demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the f
issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the pro h �
DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion proe v
bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer
MAY 10 2m
owner/ Developer /Project Manager/ Superintendanf CITY OF
Date D �,ELO . ;�
ldt�Y DE1�ELt�Pt~/Er��"
4 VU,NG
nW ENGINEERING
Letter of Transmittal
To: City of La Quinta Today's Date: 4-11-18
78-495 Calle Tampico City Due Date: 4-9-18
La Quinta, CA 92253 Project Address: 78023 San Timoteo
Attn: Mary Plan Check #: BRES2018-0119
Submittal:
1St
❑
4th
❑
2nd
❑
5th
❑
3rd
❑
Other:
We are forwarding:
i] By Messenger
❑
By Mail (Fed Ex or UPS)
❑ Your Pickup
Includes:
Descriptions:
Includes:
# Of
Descriptions:
Copies:
❑
Structural Plans
❑
Revised Struct. Plans
❑
Structural Calculations
❑
Revised Struct. Calcs
❑
Truss Calcs
❑
Revised Truss Calcs
❑
Soils Report - Update
❑
Revised Soils Report
❑
Structural P/C Responses
El
Approved Structural Plans
/ Comments
1
❑
Redlined Structural Plans
E
1
Approved Structural Calcs
❑
Redlined Structural Calcs
❑
Approved Truss Calcs
❑
Redlined Truss Calcs
❑
Approved Soils Report
❑
Redlined Soils Reports
❑
Other:
Comments: Structural content is approvable.
Transit Per Diem=
Admin Time = 0.25
hrs.
Structural Engineer/Principal Review Time = 0.0
hrs.
Plan Review Engineer Time = 1.5 hrs.
This Material Sent for:
❑ Your Files 0 Per Your Request
❑ Your Review ❑ Approval
❑ Checking ❑ At the request of:
Other: ❑
By: JOE VENUTI
Office: 0 (760) 772-5107
Other: El LQPC@VALUENGR.COM
_ FWMAppmuod
VETERANS ADMINISTRATION t U.S. DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT
ONlB Na. Zeoaaoaa
HWIFMORVACASE tom.
HEALTH AUTI4dkiTY APPROVAL
INDMDUAL WATER SUPPLY- AND- SEWAGE-OISP05A1 SYSTEM
— - -
1 oRw►oFFx
WORTANT-itde tam should bownpi*d wd Sod as rmpbed by aodfsg IM 38 U.8.C.180t+and 1810 -
PAW 1 Tq BE COMPLETED BY HUMFHA OR VA
MORTQA41ENAMEANDAWKS8 Pi W%aPCodel
MORTGAGE OR SPONSOR
RECEIVED.
PROPMWADDRESS
MAY 10 2018
IA
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
TOTALNUMSER
ISTHEREASASL;
1{t@il?
0Y6 �Ho
IS7MANSN
&STALUXI N?
-
OYES/&NO
CAN THEATTTCOR*TM AREABEMADE INTO
ADDITIONALBEDROOMS? ff/'PS$' ho+vmmry9)
Qyo>�rNo
t,IVQiGUINli8
BEDROOM
BATHS
y
Vvov}SUPPLywk
SY1NfE810 pFOR
SYSTEM Q CommulmSYSTEIM atWWUAL
NROFannoom
OARBA¢LIWPOSAL
W&MEDWO&ALOV.
,43 Ptiouc etwatt Q cosamA� ararsrett !?VDt WAL
-
❑ No
PARE 8 -TO BH COMPLETED BY HEALTH OWART Mff OR COMPLIAKCE INSPECTOR
oMECTORSSKETCH(l0RWWAS-NWDBV147MNSFWMAFPROYIDPLAN)
�a.,,�.f df flctrs�
. mnr
P -
Jf o won of the p3INe 0Cca* 0WW Dqmm Wof &d& disc this mdividueiwaterer symm [] is [� a Qot y as adomcsft wsw
•.
p "aW .. Notice
0.
anby m ttomuaa
is is the opinioa of the ❑ ComuY �Lacel Deyacm of HeaEdl thu the individual se�vag 4i i mm �FmPQ�.Ru
safis&eA n v. and is Wo-ly toctea� maaaimgr I j Canaot be d
eoadiliaas ore to mtar s� Mkb is as fo�odloa ao1Y•
RATE
TIRE ASAPPUMPM WC. TECHNICIAN
LIC At Cat &semi
Nt7i'B: Ile bias& mWwrdY Amuld oampleta the appmp=e opidm swa=ut above and affix data, sigosnae and tide in the spaces provided.
NOT& Use oitm mvem of this isat d w optical oftied healthm fi;omy.
PART III - FOR USE OF FIELD OFFICE _
i have iievfewtd the foe tagoiag addlie petddQM CompM Gtspectiaa Report and mammmnd that the iadivkW water-mp b system be
coasidaed [j acogmbie 0 zmacceptable and dw tha uaarage•disposal be coasidetwl aeeep'mble oat aet Wabk
GATE
SIGNATURE
Tffw
HUDARCHITECTURALSEC710M CHIEF OROBVNCN[EFF
p VACWEFAPPRAt8A48E.= OR OF,MM
VAF4rtRm2&aS29 AP
.r �..rartoCYaov—nwiwZatJ o ULT 1878
REP. QRT OF INSPECTION - INDIVIDUAL SEWAGE DISPOSAL SYSTEM
PRIMARY TREATMEM coiisists'af $epttc tank ❑Cesspool
SipticTanic
Distance from weak- OVIA feet Materiel. aaaceogzg= Number of components
Total fold fir•
/d= gallons. CapaW inlet componer
feet. inside width. feet. Uquid depth,, feet.
tnside length, .
Cesspaak nearest tot one at O tant ❑ side - [] rear._.— feet
Distattoe from weft. _.w._ feet. t=ouridation, •• � , � �P�Y.-----gallons. Ding material
Insidd dklmeter, ,. feet Depth,
SECONDARYTREATMl7JT consists of ❑ Tile disposal Reid' ❑ Seepage pits ' ❑ Other (spedfy )
• The Qlsposal.Meld:: -
Disianbe Wn well. ' feet, foundation: feel. nearest tot me at ❑ front ❑ side ❑ rear - feet
Tofaf [e tlt'of tft Gyres. _ --feel Nwidw of Cmee. t Oistdnee between fines. �
Trench _inches. Total etied va absorptlon area af bottom of boom -
:feet t)epth. tcRof tl[@ t013Rlsfi grade;
Type to ri aerial; : CraveE ❑ t3rotien stone � Other ( spec j►) - -
D pttt eiERifet n lea iieneath ti#e. incdtes.. LlppUt`of material overtde, iihdsrs.
Sewage.I Can -
Nhsinberorpos, . Outsidedfariketer, t ,)Cz-bo' feet. t.i "0ilirial
Distance from web,AfeA building tbruhdatlor� - �8 feet, neap Iot ttrre kWont ❑ side Q rear fie` feet.
Inspection made by: ❑ State ❑ Cohedy ' ❑ t.ocat Nealih.Airtiharity
Inspected W.
Date of Inspection: eK a J:- -16 -IAW
RF-PORT OF INSPECTION - INDMDUAL WATER.SUPPLY SYSTEM
Distance to nearest pubfiewater main, feet Size of main. inches.
IMSv1dual weft 0 are ❑are not customary in neighbofiood.
Give most nerd record of fa bye of weft in Immediate vicinity to mush aaequate supply of water
Properties in.nefghborhood ❑ are ❑ are not bei V developed with both individual water supply and sewage disposal systems.
Lot size feet wide, feet deep. Dweirng set back from property fne, feet
IndlvWW water supply from: ❑ Drilled well Q Driven well ❑ Dug well ❑ Bored well.
feet. nearest tot lie at , ❑ front ❑ side ❑tear
feet,. We sewer feet, septic tah feet, dtposat field, feet
feet, cesspoolfeet other sources of possble pollution, — -- - feet
VMj C.60stfuS tiwh .
DiBrri ri inches. Total depth, feet. Type of casting, Depth of casting. feet
Ap ..11iati.ii {e;deptfh to puinping level of water in well, feet.- Appro:drnate yield, gallons per minute.
SEWatartight to depth of feel
pacl3 aroelnd casting sealed with: ❑ Cement grout ❑ Puddled day ❑ Ord'uhary bacldff.
V1(eIi oak �`� [Concrete. +U*wd ❑ Metal. Openings in well cover watertight: ❑ Yes ❑ No.
Pump:: aS�Flallov+►weit ❑ Deep wall Length of drip pipe, fast` Pump capacity, gallons per minute
Located fn � Basement . ❑ Pumproom off baseinerd ❑ Pumphouse above'1 ❑ Pump 'plL
Pumprcjorih prop.W drained: ❑ Yes ❑ No. -Frmp mounting Watertight: ❑ Yes ONO.
Type of stotage: ❑ Pressure 0 Gravity. Capadty, gallons.
Has bacteriological examination of water been made? []Yes ❑ No. g answer WNW give date ,
apafty'of water ❑ is ❑ Is not satisfactory for human consumption.
installation ❑ does ❑ does not comply with approved exhibits , if any.
Inspection made by: Slate ❑3 County ❑ bake! Health Authority.
Inspeded by
Dale ofinsp"ecfoi"r
City of La Quinta
78-495 Calle Tampico
La Quinta, CA 92253
ATTN: AJ Ortega
Re: Slifer Residence
78-023 San Timoteo
Plan Check #BRES 2018-01 19
Dear AJ,
May 9, 2018
Please refer to the enclosed response lists regarding the corrections for 78-023 San Timoteo. Per
our telephone conversation we have defined the scope of work on the cover sheet and have
revised the site plan to show the extent of the addition of the service room and bedroom
extension. We have shown an existing floor plan to help clarify what is existing and what is new.
There are no new fixtures being added to the existing septic tank. Any further questions you may
have please let me know.
Sincerely,
STRACTS, Inc.
Anton Marinkovich
President
(760) 636.8951
STRACTSINC
ARCHITECTURE + INTERIOR DESIGN
RECEIVED
MAY 10 2018
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
550 S. OLEANDER ROAD I PALM SPRINGS, CA 92264 1 PHONE 760.636.8951 1 FAX 760.778.1314
RT/--...L�
YOUR LIFE. YOUR FIRE.
ORTAL Heating Solutions Ltd.
INSTALLATION & OPERATION MANUAL
The ORTAL direct vent (and ORTAL power vent with separate manual) gas appliances have
been tested and approved by CSA for safety .and efficiency for use with either Natural Gas (NG)
or Propane (LPG).
Standard references:
ANSI Z21.88/CSA 2.33-2014- Vented Gas Fireplace Heaters
CLASS 2901 84 — DOMESTIC HEATERS (GAS) Vented Fireplace — Certified to US Standard
CLASS 290104 — DOMESTIC HEATERS (GAS) Vented Fireplace
Pictured Above: ORTAL's Clear 110 TS
Patent Pending for screen barrier glass bracket: USSN 60/040,074
Version: February 24, 2015
MAY 10 2018
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
SUBJECT
DETAILS
TYPE OF GAS
Natural Gas (NG) or Propane (LPG)
VENT
4/6" or 5/8" Direct Vent
HEAT BARRIER
Screen (standard) or Double Glass (optional)
INTERIOR DESIGN MEDIA
Wood Style
Log Set with Embers:
Charred Oak Clay Logs
Split Oak Ceramic Fiber Logs
Driftwood Logs
Mixed Long and Short Branches with Embers
Ceramic Fiber Stones
Colors: Grey or White
Size: Large or Small
Polished Ceramic Glass
Colors: Amber, Black, Blue and Clear
General Note
Leave 20% of burner and grill uncovered by media
WEIGHT
-
Clear 40H70
206 lbs.
Clear 60x80
319 lbs.
Clear 75x65
358 lbs.
Clear 75
378 lbs.
Clear 110
383 lbs.
Clear 110H
440 lbs.
Clear 130
375 lbs.
Clear 130H
450 lbs.
Clear 150
590 lbs.
Clear 150H
767 lbs.
26
SUBJECT
DETAILS
WEIGHT
Clear 200
534 lbs.
Clear 2O0H
580 lbs.
Clear 250
621 lbs.
Clear 25OH
807 lbs.
STANDARD
Safety
ANSI Z21.88/CSA 2.33-2014
Efficiency
ANSI P.4.1-09
OPERATION
Mertik Maxitrol Remote Control (full automatic, wall control unit is optional), electronic ignition
ELECTRICAL REQUIREMENTS
All models are provided with an AC adapter which requires a 110 volts 20-amp outlet. Double Glass and Power Vent
features require an additional 2nd and 3rd outlet.
Product Specifications
The fireplace has been certified for use with either Natural Gas (NG) or Liquefied Petroleum (LPG).
All Ortal fireplaces operate with a direct vent, balanced flue venting system. A direct vent gas fireplace is room -sealed by a glass front. The flue uses natural ventilation to
pull air in from and release exhaust gases to the outside. Refer to manual for clearance distances. Installation is recommended in living spaces such as bedrooms, living
rooms, etc.
The fireplace must be properly connected to a venting system.
The fireplace must be installed according to Ortal USA requirements in addition to any local codes that may apply. If none existent, then the current CSA installation code
must be followed:
USA, ANSI Z223.1/NFPA 54
Canada, CSA B149
27
I BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Slifer Residence
78-023 San Timoteo
La Quinta, CA 92253
Project Designer:
Stracts Architecture + Interior Design
550 S. Oleander
Palm Springs, CA 92264
(760) 636-8951
Report Prepared by:
Jon d. Scott
Scott Design and Title 24, Inc
74818 Velie Way Suite 8
Palm Desert, CA 92260
(760) 200-4780
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
Job Number:
Date:
5/23/2018
-P-a Ica - 0% 1
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has: approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
I TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF-1 R-PRF-01-E Certificate of Compliance 3
Form RMS-1 Residential Measures Summary 11
Form MF-1 R Mandatory Measures Summary 12
HVAC System Heating and Cooling Loads Summary 16
Zone Load Summary 17
Room Load Summary 18
Room Heating Peak Loads 19
Room Cooling Peak Loads 21
EnergyPro 7.2 by EnergySoft Job Number ID: User Number: 6712
CERTIP : OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE F )D
Project Name: Slifer Residence Calculation Date/Time: 14:19, Wed, May 23, 2018
Calculation Description: Title 24 Analysis Input File Name: tmp4EB9.tmp.xml
CF1 F-01
Page 1 of 8
GENERAL INFORMATION
01
Project Name
Slifer Residence
02
Calculation Description
Title 24 Analysis
03
Project Location
78-023 San Timoteo
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.0 (1016 SP2)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.2
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
0
12
Project Scope
Addition and/or Alteration
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft)
4467
15
Number of Zones
2
16
Slab Area (ft2)
4467
17
Number of Stories
1
18
Addition Cond. Floor Area (ft2)
371
19
Natural Gas Available
Yes
20
Addition Slab Area (ft2)
371
21
Glazing Percentage (%)
18.2%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
4.29
3.47
0.82
19.1%
Space Cooling
156.53
156.66
-0.13
-0.1%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
5.09
5.09
0.00
0.0%
Photovoltaic Offset
--
0.00
0.00
—
Compliance Energy Total
165.91
165.22
0.69
0.4%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
NO SPECIAL FEATURES REQUIRED
Registration Number: Registration DateRme: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-05-23 14:19:58
CERTIFI "OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE F )D
Project Name: Slifer Residence Calculation Date/Time: 14:19, Wed, May 23, 2018
Calculation Description: Title 24 Analysis
Input File Name: tmp4EB9.tmp.xml
CF1 F-01
Page 2 of 8
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• --None—
Cooling System Verifications:
• -- None --
HVAC Distribution System Verifications:
• -- None --
Domestic Hot Water System Verifications:
• -- None --
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Slifer Residence
4467
1
4
2
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
addition
Conditioned
HVACex1
371
11.3
DHW Sys 1
n/a
existing residence
Conditioned
HVACex1
4096
11.3
DHW Sys 1
n/a
Registration Number: Registration DateRme: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-05-23 14:19:58
CERTIF : OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I )D
Project Name: Slifer Residence Calculation Date/Time: 14:19, Wed, May 23, 2018
Calculation Description: Title 24 Analysis
Input File Name: tmp4EB9.tmp.xml
CF1 F-01
Page 3 of 8
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door
Area (ft)
Tilt
(deg)
Status
Verified
Existing
Condition
N Wall
addition
R-21 Wall
0
Front
101
20.1
90
New
n/a
E Wall
addition
R-21 Wall
90
Left
101
0
90
New
n/a
S Wall
addition
R-21 Wall
180
Back
101
0
90
New
n/a
W Wall
addition
R-21 Wall
270
Right
306
16.5
90
New
n/a
Interior Surface
addition»existing residence
interior Wall
186
0
New
n/a
N wall 2
existing residence
default Wall
0
Front
860
118
90
Existing
No
E wall 2
existing residence
default Wall
90
Left
620
165.8
90
Existing
No
S wall 2
existing residence
default Wall
180
Back
860
327
90
Existing
No
W wall 2
existing residence
default Wall
270
Right
620
165
90
Existing
No
Interior Surface 2
existing residence>>addition
default Wall
388
0
Existing
No
Roof 2
existing residence
Defaul: 1978 to present
4096
Existing
No
OPAQUE SURFACES — Cathedral Ceilings
01
02
03
04
05
06
07
08
09
10
11
12
13
Name
Zone
Type
Orientatio
n
Area
(ft)
Skylight
Area (ft2)
Roof Rise
(x in 12)
Roof
Pitch
Roof
Tilt(deg)
Roof
Reflectan
ce
Roof
Emittance
Framin
g
Factor
Status
Verified
Existing
Condiflon
Roof
addition
R-38 Roof Attic
Front
371
0
0
0
0
0.1
0.85
0.1
New
n/a
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool
Roof
Status
Verified Existing
Condition
Attic existing residence
Attic Roofexisting residence
Ventilated
1
0.1
0.85
No
No
Existing
No
Registration Number: Registration Dateffime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-05-23 14:19:58
CERTIF °- OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I )D
Project Name: Slifer Residence Calculation Date/Time: 14:19, Wed, May 23, 2018
Calculation Description: Title 24 Analysis
Input File Name: tmp4EB9.tmp.xml
CF1 F-01
Page 4 of 8
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multiplier
Area (ft)
U-factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
Window
N Wall (Front-0)
-
--
1
20.1
0.35
0.36
Insect Screen (default)
New
n/a
Window 2
W Wall (Right-270)
--
--
1
10.5
0.35
0.36
Insect Screen (default)
New
n/a
Window 3
W Wall (Right-270)
--
-
1
6.0
0.35
0.36
Insect Screen (default)
New
n/a
Window 4
N wall 2 (Front-0)
-
-
1
64.0
0.35
0.36
Insect Screen (default)
New
n/a
existing window door slid
N wall 2 (Front-0)
-
-
1
24.0
0.71
0.60
Insect Screen (default)
Existing
No
existing window door slid 2
N wall 2 (Front-0)
-
--
1
30.0
0.71
0.60
Insect Screen (default)
Existing
No
existing window door slid 3
E wall 2 (Left-90)
-
-
1
40.0
0.71
0.60
Insect Screen (default)
Existing
No
existing window door slid 4
E wall 2 (Left-90)
--
--
1
24.0
0.71
0.60
Insect Screen (default)
Existing
No
existing window door slid 5
E wall 2 (Left-90)
--
--
1
12.5
0.71
0.60
Insect Screen (default)
Existing
No
existing window door slid 6
E wall 2 (Left-90)
--
--
1
12.5
1 0.71
0.60
Insect Screen (default)
Existing
No
Window 5
E wall 2 (Left-90)
--
--
1
13.8
0.35
0.36
Insect Screen (default)
New
n/a
existing window door slid 7
E wall 2 (Left-90)
-
-
1
15.0
0.71
0.60
Insect Screen (default)
Existing
No
existing window door slid 8
E wall 2 (Left-90)
-
--
1
48.0
0.71
0.60
Insect Screen (default)
Existing
No
Window 6
S wall 2 (Back-180)
-
--
1
64.0
0.35
0.36
Insect Screen (default)
New
n/a
Window 7
S wall 2 (Back-180)
-
-
1
44.0
0.35
0.36
Insect Screen (default)
New
n/a
existing window door slid 9
S wall 2 (Back-180)
--
--
1
24.0
0.71
0.60
Insect Screen (default)
Existing
No
Window 8
S wall 2 (Back-180)
--
--
1
96.0
0.35
0.36
Insect Screen (default)
New
n/a
existing window door slid 10
S wall 2 (Back-180)
-
-
1
24.0
0.71
0.60
Insect Screen (default)
Existing
No
existing window door slid 11
S wall 2 (Back-180)
-
--
1
15.0
0.71
0.60
Insect Screen (default)
Existing
No
existing window door slid 12
S wall 2 (Back-180)
-
--
1
15.0 1
0.71
0.60
Insect Screen (default)
Existing
No
existing window door slid 13
S wall 2 (Back-180)
-
-
1
15.0
0.71
0.60
Insect Screen (default)
Existing
No
existing window door slid 14
S wall 2 (Back-180)
--
-
1
15.0
0.71
0.60
Insect Screen (default)
Existing
No
existing window door slid 15
S wall 2 (Back-180)
--
--
1
15.0
0.71
0.60
Insect Screen (default)
Existing
No
Window 9
W wall 2 (Right-270)
--
-
1
6.0
0.35
0.36
Insect Screen (default)
New
n/a
existing window door slid 16
W wall 2 (Right-270)
-
-
1
64.0
0.71 1
0.60
Insect Screen (default)
Existing
No
existing window door slid 17
W wall 2 (Right-270)
-
--
1
12.5
0.71
0.60
Insect Screen (default)
Existing
No
existing window door slid 18
W wall 2 (Right-270)
-
--
1
12.5
0.71
0.60
Insect Screen (default)
Existing
No
existing window door slid 19
W wall 2 (Right-270)
--
--
1
18.0
0.71
0.60
Insect Screen (default)
Existing
No
Registration Number: Registration Dateffime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-05-23 14:19:58
CERTIF °- OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE F )D
Project Name: Slifer Residence Calculation Date/Time: 14:19, Wed, May 23, 2018
Calculation Description: Title 24 Analysis
Input File Name: tmp4EB9.tmp.xml
CF1 F-01
Page 5 of 8
existing window door slid 20
W wall 2 (Right-270)
--
--
1
40.0
0.71
0.60
Insect Screen (default)
Existing
No
Window 10
W wall 2 (Right-270)
—
—
1
12.0
0.35
0.36
Insect Screen (default)
New
n/a
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
• Inside Finish: Gypsum Board
• Cavity/Frame: R-30/2x10
• Roof Deck: Wood Siding/sheathing/decking
R-38 Roof Attic
Cathedral Ceilings
Wood Framed Ceiling
2x10 @ 16 in. O.C.
R 30
0.037
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity/Frame: R-21 /2x6
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
• Cavity / Frame: no insul. / 2x4
interior Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.277
Other Side Finish: Gypsum Board
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofexisting residence
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
Defaul: 1978 to present
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 11
0.083
Over Ceiling Joists: R-1.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R-11 /2x4
default Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 11
0.110
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
• Cavity/Frame: R-11 /2x4
default Wall
Interior Walls IWood
Framed Wall
2x4 @ 16 in. O.C.
R 11
0.099
Other Side Finish: Gypsum Board
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft)
Perimeter
(ft)
Edge Insul. R-value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Slab -on -Grade
addition
371
0.07
None
0.8
No
New
No
Slab -on -Grade 2
existing residence
4096
186
None
0.8
No
Existing
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-05-23 14:19:58
CERTIF : OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I )D
Project Name: Slifer Residence Calculation Date/Time: 14:19, Wed, May 23, 2018
Calculation Description: Title 24 Analysis
Input File Name: tmp4EB9.tmp.xml
CF1 F-01
Page b of 8
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
0
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Input Rating /
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss I
First Hour
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
NEEA Heat Pump
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Brand / Model
Condition
DHW Heater 1
Gas
Small Storage
1
1 50
1 0.61 EF
140,000 Btu/hr
0
n/a
n/a
I n/a
I n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution
Name
Status
Verified Existing
Condition
HVACex1
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution
System 1
Existing
No
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R-value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
System 1
(Ventilated and
specified)
8.0
Attic
Attic
None
Existing
No
Na
Unventilated)
Registration Number: Registration DatefTime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-05-23 14:19:58
CERTIP : OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE N )D
Project Name: Slifer Residence Calculation Date/Time: 14:19, Wed, May 23, 2018
Calculation Description: Title 24 Analysis
Input File Name: tmp4EB9.tmp.xml
CF1 F-01
Page 7 of 8
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
0
0.25
Default
0
Not Required
Registration Number: Registration Datemme: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-05-23 14:19:58
CERTIF = OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I DD
Project Name: Slifer Residence Calculation Date/Time: 14:19, Wed, May 23, 2018
Calculation Description: Title 24 Analysis
Input File Name: tmp4EB9.tmp.xml
CF1 F-01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Jon d. Scott
Jon d. Scott
Company:
Signature Date: 5-23-18
Scott Design and Title 24, Inc,
5/23/2018 pc Corr
Address:
CEA/HERS Certification Identification (If applicable):
74818 Velie Way Suite 8
city/Stat I .1m Desert, CA 92260
Phone: (760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Stracts Architecture + Interior Design
Company:
Date Signed:
Stracts Architecture + Interior Design
Address:
License:
550 S. Oleander
City/State/Zip:
Palm Springs, CA 92264
Phone:
(760) 636-8951
Registration Number: Registration Date[Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-05-23 14:19:58
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Slifer Residence
Building Type
m Single Family ❑ Addition Alone
❑ Multi Family 0 Existing+ Addition/Alteration
Date
5/23/2018
Project Address
78-023 San Timoteo La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,467
Addition
371
# of Units
1
INSULATION
Construction Type
Cavity
Area
ffz Special Features Status
Roof Wood Framed Rafter R 30
371 New
Wall Wood Framed R 21
572 New
Slab Unheated Slab -on -Grade - no insulation
371 Perim = 0' New
Demising Wood Framed - no insulation
186 New
Roof Wood Framed Attic R 11
4,096 Existing
Wall Wood Framed R 11
2,572 Existing
Slab Unheated Slab -on -Grade - no insulation
4,096 Perim = 186' Existing
FENESTRATION I Total Area: 812 Glazing Percentage: 18.2% New/Altered Average U-Factor: 0.35
Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades Status
Front (N) 84.1 0.350
0.36 none
none Bug Screen New
Right (W) 34.5 0.350
0.36 none
none Bug Screen New
Front (N) 54.0 0.710
0.60 none
none Bug Screen Existing
Left (E) 152.0 0.710
0.60 none
none Bug Screen Existing
Left (E) 13.8 0.350
0.36 none
none Bug Screen New
Rear (S) 204.0 0.350
0.36 none
none Bug Screen New
Rear (S) 123.0 0.710
0.60 none
none Bug Screen Existing
Right (W) 147.0 0.710
0.60 none
none Bug Screen Existing
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling
Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 16.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Cooling
Duct
Duct Location R-Value Status
HVACex Ducted
Ducted
Attic 8.0
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnerqvPro 7.2 by EnerqySoft User Number: 6712
ID: Page 11 of 24
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. *Exceptions may apply.
un inai Udr1U1b
Building Envelope Measures:
§ 110.6(a)l:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per
NFRC-400 or ASTM E283 or AAMAIWDMA/CSA 101II.S.2/A440-2011:
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
110.6-A and 110.6-B for compliance and must be caulked and/or weatherstried.'
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of 110.8 i when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceiling.*
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or
§ 150.0(c):
less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a
wood framed assembly.*
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.'
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g).
§ 150.0(g)1:
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d).
§ 150.0(g)2:
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)lA:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)l B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)1C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.*
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.'
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.*
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)5.
§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
§ 110.5:
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool and spa heaters.'
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)l:
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; orACCA
Manual J using design conditions specified in 4 150.0(h)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
dryer vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures'
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve.'
§ 150.00)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
pipinq for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.'
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.00)3B:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)1:
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation SRCC or by a listing agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1:
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tape is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0 m 11 and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of § 150.0(m)12.
a2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy:5 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RAU. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced airs stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
§ 150.0(o)1A:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating!
§ 110.4(b)1:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0
§ (p)'
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, piping, filters, and valves.'
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of § 110.9.'
§ 110.9(e):
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fanspeed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)1 D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors.
§ 150.0(k)1 F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(k).'
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1G:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8.'
§ 150.0(k)1 H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5 ; and meets all other requirements in § 150.0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5 ; and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways!
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS.
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either § 150.0 k 3A or with the applicable requirements in 110.9,130.0, 130.2, 130.4,140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0 k 3B or 4 150.0 k 3D must comply with the applicable requirements in §§ 110.9,130.0,130.2,130.4, 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 wafts of
power as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9,130.0,130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.1 0b through § 110.10 e .
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.*
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical lane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.1 0c must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Slifer Residence
Date
5/23/2018
System Name
HVACex
Floor Area
4,467
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 4,263
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
81,732
5,783
1,758
63,240
Total Output Btuh
89,000
0
Output Btuh/s ft
19•9
4,718
3,108
Cooling System
0
0
Output per System
35,500
0
0
0
0
Total Output Btuh
35,500
0
5,783
0
Total Output Tons
3.0
4,718
3,108
Total Output Btuh/s ft
7.9
Total Output s ft/Ton
1,510.0
1 91,169
F 69,456
Air System
CFM perSystem
1,400
HVAC EQUIPMENT SELECTION
Airflow cfm
1,400
HVAC
26,499
3,996
89,000
Airflow cfm/s ft
0.31
Airflow cfm/Ton
473.2
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
26,499
3,996
89,000
Outside Air cfm/s ft
0.00
Jan 1 AM
Note: values above given at ARI conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF 69 OF 105 OF 105 OF
Outside Air
0 cfm Heating Coil Supply Fan
1,400 cfm
69 OF Return Fan 69 OF
1,400 cfm
104 o F
ROOM
70 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112/78OF 77/63OF 55/54OF 55/54OF
Outside Air
0 cfm Cooling Coil Supply Fan
1,400 cfm
Return Fan
77 / 63 OF 77 / 63 IF
® 1,400 cfm `
57 / 55 OF
48.9% ROOM
75 / 62 OF
I
EnergyPro 7.2 by EnergySoR
User Number. 6712
ID: Page 16 of 24
'ZONE•AD SUMMARY
Project,-.
Residence
512312018
System Name
HVACex
FloorSlifer
4.
ZONE LOAD
ZONAL SYSTEM
..
SYSTEM NAME
existing residence
LOAD)
EnergyPro
ROOM LOAD SUMMARY
Project Name Date
Slifer Residence 512312018
HVACex 4,467
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
addition additions 78-023 San Tim 1 241 4,626 480 241 4,626 480 90 3,431
existing residence 78-023 San Timoteo 1 1 4,022 77,107 5,303 4,022 77,107 5,303 1,668 59,809
PAGE TOTAL
TOTAL'
4,263
81,7321
5,7831
1,7581
63, 240
4,2631
81,7321
5,7831
1,7581
63, 240
Total includes ventilation load for zonal systems.
EnergyPro 7.2 by EnerqySoft User Number: 6712 ID: Page 18 of 24
ROOM HEATING PEAK LOADS
Project Name
Slifer Residence
Date
512312018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name additions 78-023 San Timoteo
Floor Area 371.00 ft2
Indoor Dry Bulb Temperature 68 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT OF
0
=
=
c
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
42
Btu/hr
R-38 Roof Attic
371.0
0.0360
42
561
R-21 Wall
572.4
0.0690
42
1,659
slider windows Door ..35/.36
36.6
0.3500
42
538
Slab -On -Grade
penim = 0.1
0.7300
42
2
`interior Wall
186.0
0.3560
-2
-132
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 371 X
Area
another room
11.30 X 0.257
Height ACH
Page Total
/ 60 ] X
AT
Z628
= 803
TOTAL HOURLY HEAT LOSS FOR ROOM 3,431
EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 19 of 24
ROOM BEATING PEAK LOADS
Project Name
Slifer Residence 75/23/2018
Date
ROOM INFORMATION
DESIGN CONDITIONS
Room Name 78-023 San Timoteo
Floor Area 4,096.00 ft2
Indoor Dry Bulb Temperature 70 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U-Value
X 0.0790
X 0.1100
X 0.3500
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
44
Btu/hr
Default 1978 to present
4,096.0
44
14,238
default Wall
2,184.2
44
10,572
slider windows Door ..35/.36
299.8
44
4,617
Existing Window
476.0
X
0.7100
44
14,870
Slab -On -Grade
perim = 186.0
X
0.7300
44
5,974
*default Wall
388.0
X
0.1100
2
85
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (*) denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 4,096 X
Area
to another room
11.30 X 0.262
Ceiling Height ACH
Page Total
/ 60 ] X
AT
50,356
= 9,453
TOTAL HOURLY HEAT LOSS FOR ROOM 59,809
EnergyPro 7.2 by EnergySoft User Number.- 6712 ID: Page 20 of 24
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Slifer Residence
5/23/2018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
additions 78-023 San Timoteo
Outdoor Dry Bulb Temperature
112 OF
Floor Area
371.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF
I Outdoor Daily Range.
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
R-38 Roof Attic
(N) 371.0 X 0.0360
X
56.0 =
748
R-21 Wall
(N) 80.9 X 0.0690
X
23.0 =
128
R-21 Wall
(E) 101.0 X 0.0690
X
33.0 =
230
R-21 Wall
(S) 101.0 X 0.0690
X
26.0 =
181
R-21 Wall
(W) 289.5 X 0.0690
X
33.0 =
659
'interior Wall
186.0 X 0.3560
X
0.0 =
0
X
X
=
X
X
=
X J
X
=
Page Total
1,947
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
Window
(N) 0.0 X 20.4 +
20.1 X
20.4 =
409
Window
(W) 0.0 X 20.4 +
10.5 X
41.7 =
438
Window
(W) 0.0 X 20.4 +
6.0 X
41.7 =
250
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +
X
=
X +1
ix
=
Page Total
1,098
Internal Gain
Btu/hr
Occupants
11 Occupants X 245
Btuh/occ.
=
E:A
Equipment
371 Floor Area X 0.50
w/sgft
=
Infiltration: 1.064
X 0.89 X 19.21 X 37 =
675
Air Sensible
CFM ELA 4T
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
4,626
Latent Gain
Btu/hr
Occupants
11 Occupants X 155
Btuh/occ.
=
173
Infiltration: 4,771
X 0.89 X 19.21 X 0.00376 =
308
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
173
EnergyPro 7.2 by EneriqySoft
User Number: 6712 ID:
Page 21 of 24
RESIDENTIAL ROOM COOLING LOAD SUMMARY
rrolect Name Date
Slifer Residence 512312018
ROOM INFORMATION. DESIGN CONDITIONS
Room Name 78-023 San Timoteo Outdoor Dry Bulb Temperature 112 OF
Floor Area 4,096.00 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 75 OF Outdoor Daily Ranue: 34 OF
Opaque Surfaces
Defaul: 1978 to present
default Wall
default Wall
default Wall
default Wall
-default Wall
Orientation
(N)
(N)
(E)
(S)
(W)
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
4,096.0
0.0790
56.0
742.0
0.1100
23.0
454.2
0.1100
33.0
533.0
0.1100
26.0
455.0
0.1100
33.0
388.0
0.1100
0.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
Window
existing window door slider
existing window door slider
existing window door slider
existing window door slider
existing window door slider
existing window door slider
Window
existing window door slider
Orientation
(N)
(N)
(N)
(E)
(E)
(E)
(E)
(E)
(E)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
-
0.0
20.4
64.0
20.4
0.0
36.5
24.0
36.5
0.0
36.5
30.0
36.5
0.0
36.5
40.0
72.1
0.0
36.5
24.0
72.1
0.0
36.5
12.5
72.1
0.0
36.5
12.5
72.1
0.0
20.4
13.8
41.7
0.0
36.5
15.01
1 72.1
Page Total
Btu/hr
18,121
1,877
1,649
1,524
1,6521
0
24,823
Btu/h r
1,303
875
1,094
2, 883
1,730
901
901
576
1,081
11.345
Internal Gain
Btu/hr
Occupants
12.3 Occupants X
245 Btuh/occ. = 3,014
Equipment
4,096 Floor Area X
0.50 w/sgft = 6,990
Infiltration: 1.064 X 0.89 X 212.12 X 37 = 7,454
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 77,1071
Latent Gain Btu/hr
Occupants 12.3 Occupants X 155 Btuh/occ. = 1,907
Infiltration: 4,771 X 0.89 X 212.12 X 0.00376 = 3,396
Air Sensible CFM ELA AW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1.9071
of 24
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Slifer Residence 5/23/2018
ROOM INFORMATION DESIGN CONDITIONS
Room Name
78-023 San Timoteo
Outdoor Dry Bulb Temperature
112 OF
Floor Area
4,096.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
75 °F
Outdoor Daily Ranqe:
34 OF
Surfaces
Orientation
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
FPnP_Stratinn
existing window door slider
Window
Window
existing window door slider
Window
existing window door slider
existing window door slider
existing window door slider
existing window door slider
r)riantatinn
(E)
(S)
(S)
(S)
(S)
(S)
(S)
(S)
(S)
Shaded Unshaded
Area
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
0.0
36.5
48.0
72.1
0.0X
20.4+
64.0X
20.4=
0.0
20.4
44.0
20.4
0.0
36.5
24.0
36.6
0.0
20.4
96.0
20.4
0.0
36.5
24.0
36.6
0.0
36.5
15.0
36.6
0.0
36.5
15.0
36.6
0.0X
36.5+
15.0X
Page Total
Btu/hr
Btu/h r
3,460
1,308
9001
I�
879
1,963
879
549
549
549
11.035
internal uain Btu/hr
Occupants 12.3 Occupants X 245 Btuh/occ. = 3,014
Equipment 4,096 Floor Area X 0.50 w/sgft = 6,990
Infiltration: 1.064 X 0.89 X 212.12 X 37 = 7,454
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 77,1071
Latent Gain Btu/hr
Occupants 12.3 Occupants X 155 Btuh/occ. = 1,907
Infiltration: 4,771 X 0.89 X 212.12 X 0.00376 = 3,396
Air Sensible CFM ELA AW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1.9071
24
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Slifer Residence 5/23/2018
ROOM INFORMATION DESIGN CONDITIONS
Room Name
78-023 San Timoteo
Outdoor Dry Bulb Temperature
112 OF
Floor Area
4,096.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
75 OF
Outdoor Daily Ranqe:
34 OF
ue Surfaces
Orientation
Area U-Factor CLTD'
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
X X =
Page Total
Items shown with an asterisk (*) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
I Fenestratinn
existing window door slider
existing window door slider
Window
existing window door slider
existing window door slider
existing window door slider
existing window door slider
rd
ng window door slider
ow
Orientatinn
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
-
=
0.0
36.5
15.0
36.6
0.0
36.5
15.0
36.6
0.0
20.4
6.0
41.7
0.0
36.5
64.0
72.1
0.0
36.5
12.5
72.1
0.0
36.5
12.5
72.1
0.0
36.5
18.0
72.1
0.0
36.5
10.01
72.1
0.0
20.4
12.0
41.7
Page Total
Btu/hr
Ul
Btu/hr
549
549
250
4,614
901
901
1,298
2,883
501
12.446
Internal Gain Btu/hr
Occupants 12.3 Occupants X 245 Btuh/occ. = 3,014
Equipment 4,096 Floor Area X 0.50 w/sgft = 6,990
Infiltration: 1.064 X 0.89 X 212.12 X 37 = 7,454
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 77,1071
Latent Gain Btu/hr
Occupants 12.3 Occupants X 155 Btuh/occ. = 1,907
Infiltration: 4,771 X 0.89 X 212.12 X 0.00376 = 3,396
Air Sensible CFM ELA AW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,907
User