Loading...
BRES2018-011978-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: . Applicant: ANTON MARINKOVICH 5S0 S OLEANDER RD PALM SPRINGS, CA 92264 Liht U VOICE (760) 777-7125 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 5/29/2018 BUILDING RESIDENTIAL/ADDITION E Owner: BRES2018-0119 WILLIAM SLIFER 78023 SAN TIMOTEO STST I� 5701 E STANFORD DR 646160003 4J ENGLEWOOD, CO 92253 SLIFER / 371SF ADDITION AN 14 EMODEL 29�$ $250,000.00 �Q��Ni FpQaiMN� Contractor: MONARCH HOMES DESERT DIVISION INC DBA DA 49-950 JEFFERSON ST #130-134 INDIO, CA 92201 (760)413-8863 Llc. No.: 457228 LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter I hereby affirm under penalty of perjury one of the following declarations: 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, _ I have and will maintain a certificate of consent to self -insure for workers' and my License is in full force and effect. compensation, as provided for by Section 3700 of the Labor Code, for the performance License Class: B License No.: 457228 of the work for which this permit is issued. q C� / . /— 1 have and will maintain workers' compensation insurance, as required by Date: -9- °Z I ' ( O Contractg11 �j �/ f Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: OWNER -BUILDER DEQARATION Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 9045509 1 hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any _ I certify that in the performance of the work for which this permit is issued, I city or county that requires a permit to construct, alter, improve, demolish, or repair shall not employ any person in any manner so as to become subject to the workers' any structure, prior to its issuance, also requires the applicant for the permit to file a compensation laws of California, and agree that, if I should become subject to the signed statement that he or she is licensed pursuant to the provisions of the workers' compensation provisions of Section 3700 of the I shall forthwith Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 7Laboe, comply with those provisions. 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a Date: �' Applican . / permit subjects the applicant to a civil penalty of not more than five hundred dollars � ($500).: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, (_) I, as owner of the property, or my employees with wages as their sole AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO compensation, will do the work, and the structure is not intended or offered for sale. ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, apply to an owner of property who builds or improves thereon, and who does the work INTEREST, AND ATTORNEY'S FEES. himself or herself through his or her own employees,: provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold APPLICANT ACKNOWLEDGEMENT within one year of completion, the owner -builder will have the burden of proving that IMPORTANT: Application is hereby made to the Building Official for a permit subject to he or she did not build or improve for the purpose of sale.). the conditions and restrictions set forth on this application. (_) I, as,owner of the property, am exclusively contracting with licensed contractors 1. Each person upon .whose behalf this application is made, each person at whose to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' request and for whose benefit work is performed under or pursuant to any permit State License Law does not apply to an owner of property who builds or improves issued as a result of this application , the owner, and the applicant,. each agrees to, and thereon, and who contracts for the projects with a contractor(s) licensed pursuant to shall defend, indemnify and hold harmless the City of La Ctuinta, its officers, agents, and the Contractors' State License Law.). employees for any act or omission related to the work being performed under or ( ) I am exempt under Sec. - B.&P.C. for this reason following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of Date: Owner: work for 180 days will subject permit to cancellation. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,. and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. Date: Signature (Applicant or A0 Qn4 Date: 5/29/2018 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: ANTON MARINKOVICH 550 S OLEANDER RD PALM SPRINGS, CA 92264 BRES2018-0119 78023 SAN TIMOTEO ST ST 646160003 SLIFER / 371SF ADDITION AND INTERIOR REMODEL $250,000.00 Owner: WILLIAM SLIFER 5701 E STANFORD DR ENGLEWOOD, CO 92253 Contractor: MONARCH HOMES DESERT DIVISION INC DBA DA 49-950 JEFFERSON ST #130-134 INDIO, CA 92201 (760)413-8863 Llc. No.: 457228 Detail: SLIFER / 371 SF ADDITION + INTERIOR REMODEL TO EXISTING 4,096 S.F. HOME, RESULTING IN A TOTAL OF 4,467 SF. NEW SERVICE ROOM 278 SF AND SITTING ROOM 93 SF UNDER EXISTING PATIO ROOF. REVISE CURRENT LAYOUT OF INTERIOR WALLS AND ELECTRICAL TO ACCOMMODATE NEW FLOOR PLAN. REPLACE [81 WINDOWS, RELOCATE WATER HEATER AND HVAC. INSTALL NEW FIREPLACE AT LIVING ROOM.[ENGINEERED) SMOKE/CO ALARMS TO BE FIELD VERIFY. THIS PERMIT DOES NOT INCLUDE THE REPLACEMENT OF ELECTRICAL SERVICE PANEL. 2016 CALIFORNIA BUILDING CODES. 1 INFORMATION FINANCIAL DESCRIPTION ACCOUNT CITY AMOUNT ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 . $67.10 DESCRIPTION ACCOUNT CITY AMOUNT ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $18.72 ' DESCRIPTION ACCOUNT CITY AMOUNT ADDITION, FIRST 100 SF 101-0000-42400 0 $131.07 DESCRIPTION ACCOUNT CITY AMOUNT ADDITION, FIRST 100 SF PC 101-0000-42600 0 $184.13 Total Paid for ADDITION: $401.02 DESCRIPTION ACCOUNT CITY AMOUNT ART IN PUBLIC PLACES.-, RESIDENTIAL 270-0000-43201 0 $125.00 Total Paid for ART IN PUBLIC PLACES - AIPP: $125.00 DESCRIPTION ACCOUNT CITY AMOUNT HOURLY CHARGE - YES HISTORIC 101-0000-42600 0 $10.00 DESCRIPTION ACCOUNT CITY AMOUNT HOURLY CHARGE -YES STRUCTURAL PLAN REVIEW ENGINEER 101-0000-42600 1 1.5 1 $142.50 Total Paid for BLDG CITY STAFF - PER HOUR: $152.50 DESCRIPTION ACCOUNT CITY AMOUNT . BSAS SB1473 FEE 101-0000-20306 0 $10.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 1$26.01 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES/FIXTURES, ADDITIONAL 101-0000-42403 0 $345.80 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES/FIXTURES, ADDITIONAL PC 101-0000-42600 0 $86.45 Total Paid for ELECTRICAL: $484.27 DESCRIPTION ACCOUNT CITY AMOUNT ' FURNACE 101-0000-42402 0 $39.01 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE PC 101-0000-42600 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN 101-0000-42402 0 $104.00 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN PC 101-0000-42600 0 $41.60 DESCRIPTION ACCOUNT CITY AMOUNT WALL HEATER 101-0000-42402 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT WALL HEATER PC 101-0000-42600 0 $13.00 Total Paid for MECHANICAL: $249.63 DESCRIPTION ACCOUNT QTY AMOUNT PARTITION 101-0000-42400 0 $78.02 DESCRIPTION ACCOUNT QTY AMOUNT PARTITION PC 101-0000-42600 0 $143.56 Total Paid for PARTITION: $221.58 DESCRIPTION ACCOUNT CITY AMOUNT PLAN CHECK DEPOSIT-ADDITION/REMODEL 101-0000-42600 1 7 $250.00 Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $250.00 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $169.00 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $169.00 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER CHANGEOUT 101-0000-42401 0 $13.00 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER CHANGEOUT PC 101-0000-42600 0 $7.80 Total Paid for PLUMBING FEES: $358.80 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $20.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $20.00 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $32.50 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $32.50 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT QTY AMOUNT DOOR/WINDOW, RETRO/REPAIR, FIRST 101-0000-42400 0 .$6S.54 DESCRIPTION ACCOUNT QTY AMOUNT DOOR/WINDOW, RETRO/REPAIR, FIRST 7 PC 101-0000-42600 0 $63.98 Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $129.52 tevQa (ePERMIT# EM flh,DESERT 'I—(,(/ PLAN LOCATION: rJ� Project Address: -% Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: CoS p . �3G Flo SUI %tea-�lJi�7�itJ- .mil Sia1V l �UT�2� � Applicant Name: AA17',7j/,/ Address: 5750 S. O City, ST, Zip: P&61 Telephone: S- Email: g���h s fj^�G , .�� Valuation of Project $ o,-e,O Contractor Name: New SFD Construction: Address: Conditioned Space 1:5 7 % SF City, St, Zip Garage SF Telephone: Patio/Porch SF Email: Fire Sprinklers SF State UcAlgiJ-10; .. City Bus Lic: Arch/Eng Name:AX-AWle- GAGA Construction Type: /LGNW1i��p Occupancy:�`3/(J/ Address: . -r-O . S - G Grading: City, St, Zip PjgLm 5Piz1`v Telephone: 7 $� / . Bedrooms: Stories: # Units: Email: 11 S lip. Gr1yYJ State Lic:G`19� City Bus Lic:�`l%y�0�2 SF Property Owner's Name: AIGL G SG/ New Commercia / Tenan mprovements: Address: 7b _0jz Total Building SF City; ST, Zip G� Z Construction Type: Occupancy: Telephone: 363 Email: S�u/S�i G�OI cG� 78495 CALLE TAMPICO LA CLU1NTA, CA 92253 760-777-7000 Date: 5/25/2018 No.: 18-00971-1 Owner: William Slifer Address: 78-023 Timoteo St City: La Quinta Type: Residential Addition < 500 Sq ft Lot # Street No. 78-023 Comments: CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760)771-8515 Street Name San Timoteo St JN�Ft£O. Q2y 6 vl BEalau'FIn OUid£s r. e- �iruo�wE y r6 PCOA DESERT w � tAISTAA o rNMo 1'`-0 Email: Jurisdiction: La Quinta Tract #: Sq. Feet APN Permit No. 371 646-160-003 RECEIVED MAY 2 5 20% CITY OF lA QUWT;a DESIGN AND DEVE? O ':' . - WMW At the present time, the Desert Sands Unified School District does not:collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement. mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less. Exempt This certifies that school facility fens imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 371 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: Exempt/Greg Bonano Check No.: Bank Name/Recipient of Certificate Telephone: 949-283-0365 Funding: Exempt By Scott L. Bailey Superintendent Fee Collected/ Exempted by: Arianne Catano Certificate. -Fees Dua: $0.00 Original Paymeh(s) Rec'sd: $0.00 New Payment Rec'A: $0.00 Qve�/Under: $O..00 J NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or other payment identified above will begin to run from the date on. which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. From: charlle coulter charlie@bunkerbrokers.com Subject: Remodel 78023 San Timoteo La Quinta Date: March 6, 2018 at 3:40 PM To: Slifer, Carol sewsli@aol.com Cc: Marinkovich Anton anton@stracts.com Mr. & Mrs. Slifer, This email is to confirm that I have reviewed your plans for your project. Based on those' plans I approve your request on behalf of the La Quinta Golf Estate HOA. Chairman of the Architectural Committee. Charlie Coulter Coulter & Associates, Inc. www.LaQuintaCountryClubs.com 760.777.8822 1! o Virus -free. www.avast.com RECEIVED MAY 10 2018 CITY OF LA QUINTA COMMUNITY DEVELOPMENT Building Permit Number: Project Description: Rm Addition & Remodel Exempt: ❑ (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Plan Submittal Date Job Site Address Owner's Name Number, Street, or PO Box City, State, Postal Code Owner's Phone Number Owner's E-Mail Address Project Manager's Name Project Managers Phone Number Project Manager's E-mail Address Builder / Contractor Number, Street or PO Box City, State, Postal Code 4/27/2018 78025 San Timoteo Carol & Bones Slifer 78025 San Timoteo La Quinta, CA. 92253 760-564-4106 Greg Bonano 949-283-0365 greobonanoL@omail.com David Jacobsen Building Co. 49950 Jefferson St #130-134 Indio, CA. 92201 Project Square Footage Approx. 314sq ft (addition)/2,000sq ft (remodel) City Approval By Renado Gouldlock-DEC/Burrtec Waste 2 , Date of City Approval Materials To Be Discarded: Product Trash Asphalt Brick/Block Cardboard Commingled Concrete Drywall Donated / Reuse'' *Describe Items Tons Not recyclable Product Tons Recyclable Masonry (broken) 0.00 Recyclable Recyclable Plaster 1.10 Recyclable Recyclable Scrap Metal 0.00 Recyclable Recyclable Tile (floor) 0.10 Recyclable Recyclable Tile (roof} 0.13 Recyclable Recyclable Wood 1.70 Recyclable Recyclable Landscape Debris 0.00 Recyclable 4.00 0.00 0.00 0.00 0.00 4.00 0.50 0.0-01 Totals: Recycle Trash Projected Diversion: 7.51 4.0E-6-5.3-19/0 I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the f issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the pro h � DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion proe v bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer MAY 10 2m owner/ Developer /Project Manager/ Superintendanf CITY OF Date D �,ELO . ;� ldt�Y DE1�ELt�Pt~/Er��" 4 VU,NG nW ENGINEERING Letter of Transmittal To: City of La Quinta Today's Date: 4-11-18 78-495 Calle Tampico City Due Date: 4-9-18 La Quinta, CA 92253 Project Address: 78023 San Timoteo Attn: Mary Plan Check #: BRES2018-0119 Submittal: 1St ❑ 4th ❑ 2nd ❑ 5th ❑ 3rd ❑ Other: We are forwarding: i] By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: Descriptions: Includes: # Of Descriptions: Copies: ❑ Structural Plans ❑ Revised Struct. Plans ❑ Structural Calculations ❑ Revised Struct. Calcs ❑ Truss Calcs ❑ Revised Truss Calcs ❑ Soils Report - Update ❑ Revised Soils Report ❑ Structural P/C Responses El Approved Structural Plans / Comments 1 ❑ Redlined Structural Plans E 1 Approved Structural Calcs ❑ Redlined Structural Calcs ❑ Approved Truss Calcs ❑ Redlined Truss Calcs ❑ Approved Soils Report ❑ Redlined Soils Reports ❑ Other: Comments: Structural content is approvable. Transit Per Diem= Admin Time = 0.25 hrs. Structural Engineer/Principal Review Time = 0.0 hrs. Plan Review Engineer Time = 1.5 hrs. This Material Sent for: ❑ Your Files 0 Per Your Request ❑ Your Review ❑ Approval ❑ Checking ❑ At the request of: Other: ❑ By: JOE VENUTI Office: 0 (760) 772-5107 Other: El LQPC@VALUENGR.COM _ FWMAppmuod VETERANS ADMINISTRATION t U.S. DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT ONlB Na. Zeoaaoaa HWIFMORVACASE tom. HEALTH AUTI4dkiTY APPROVAL INDMDUAL WATER SUPPLY- AND- SEWAGE-OISP05A1 SYSTEM — - - 1 oRw►oFFx WORTANT-itde tam should bownpi*d wd Sod as rmpbed by aodfsg IM 38 U.8.C.180t+and 1810 - PAW 1 Tq BE COMPLETED BY HUMFHA OR VA MORTQA41ENAMEANDAWKS8 Pi W%aPCodel MORTGAGE OR SPONSOR RECEIVED. PROPMWADDRESS MAY 10 2018 IA CITY OF LA QUINTA COMMUNITY DEVELOPMENT TOTALNUMSER ISTHEREASASL; 1{t@il? 0Y6 �Ho IS7MANSN &STALUXI N? - OYES/&NO CAN THEATTTCOR*TM AREABEMADE INTO ADDITIONALBEDROOMS? ff/'PS$' ho+vmmry9) Qyo>�rNo t,IVQiGUINli8 BEDROOM BATHS y Vvov}SUPPLywk SY1NfE810 pFOR SYSTEM Q CommulmSYSTEIM atWWUAL NROFannoom OARBA¢LIWPOSAL W&MEDWO&ALOV. ,43 Ptiouc etwatt Q cosamA� ararsrett !?VDt WAL - ❑ No PARE 8 -TO BH COMPLETED BY HEALTH OWART Mff OR COMPLIAKCE INSPECTOR oMECTORSSKETCH(l0RWWAS-NWDBV147MNSFWMAFPROYIDPLAN) �a.,,�.f df flctrs� . mnr P - Jf o won of the p3INe 0Cca* 0WW Dqmm Wof &d& disc this mdividueiwaterer symm [] is [� a Qot y as adomcsft wsw •. p "aW .. Notice 0. anby m ttomuaa is is the opinioa of the ❑ ComuY �Lacel Deyacm of HeaEdl thu the individual se�vag 4i i mm �FmPQ�.Ru safis&eA n v. and is Wo-ly toctea� maaaimgr I j Canaot be d eoadiliaas ore to mtar s� Mkb is as fo�odloa ao1Y• RATE TIRE ASAPPUMPM WC. TECHNICIAN LIC At Cat &semi Nt7i'B: Ile bias& mWwrdY Amuld oampleta the appmp=e opidm swa=ut above and affix data, sigosnae and tide in the spaces provided. NOT& Use oitm mvem of this isat d w optical oftied healthm fi;omy. PART III - FOR USE OF FIELD OFFICE _ i have iievfewtd the foe tagoiag addlie petddQM CompM Gtspectiaa Report and mammmnd that the iadivkW water-mp b system be coasidaed [j acogmbie 0 zmacceptable and dw tha uaarage•disposal be coasidetwl aeeep'mble oat aet Wabk GATE SIGNATURE Tffw HUDARCHITECTURALSEC710M CHIEF OROBVNCN[EFF p VACWEFAPPRAt8A48E.= OR OF,MM VAF4rtRm2&aS29 AP .r �..rartoCYaov—nwiwZatJ o ULT 1878 REP. QRT OF INSPECTION - INDIVIDUAL SEWAGE DISPOSAL SYSTEM PRIMARY TREATMEM coiisists'af $epttc tank ❑Cesspool SipticTanic Distance from weak- OVIA feet Materiel. aaaceogzg= Number of components Total fold fir• /d= gallons. CapaW inlet componer feet. inside width. feet. Uquid depth,, feet. tnside length, . Cesspaak nearest tot one at O tant ❑ side - [] rear._.— feet Distattoe from weft. _.w._ feet. t=ouridation, •• � , � �P�Y.-----gallons. Ding material Insidd dklmeter, ,. feet Depth, SECONDARYTREATMl7JT consists of ❑ Tile disposal Reid' ❑ Seepage pits ' ❑ Other (spedfy ) • The Qlsposal.Meld:: - Disianbe Wn well. ' feet, foundation: feel. nearest tot me at ❑ front ❑ side ❑ rear - feet Tofaf [e tlt'of tft Gyres. _ --feel Nwidw of Cmee. t Oistdnee between fines. � Trench _inches. Total etied va absorptlon area af bottom of boom - :feet t)epth. tcRof tl[@ t013Rlsfi grade; Type to ri aerial; : CraveE ❑ t3rotien stone � Other ( spec j►) - - D pttt eiERifet n lea iieneath ti#e. incdtes.. LlppUt`of material overtde, iihdsrs. Sewage.I Can - Nhsinberorpos, . Outsidedfariketer, t ,)Cz-bo' feet. t.i "0ilirial Distance from web,AfeA building tbruhdatlor� - �8 feet, neap Iot ttrre kWont ❑ side Q rear fie` feet. Inspection made by: ❑ State ❑ Cohedy ' ❑ t.ocat Nealih.Airtiharity Inspected W. Date of Inspection: eK a J:- -16 -IAW RF-PORT OF INSPECTION - INDMDUAL WATER.SUPPLY SYSTEM Distance to nearest pubfiewater main, feet Size of main. inches. IMSv1dual weft 0 are ❑are not customary in neighbofiood. Give most nerd record of fa bye of weft in Immediate vicinity to mush aaequate supply of water Properties in.nefghborhood ❑ are ❑ are not bei V developed with both individual water supply and sewage disposal systems. Lot size feet wide, feet deep. Dweirng set back from property fne, feet IndlvWW water supply from: ❑ Drilled well Q Driven well ❑ Dug well ❑ Bored well. feet. nearest tot lie at , ❑ front ❑ side ❑tear feet,. We sewer feet, septic tah feet, dtposat field, feet feet, cesspoolfeet other sources of possble pollution, — -- - feet VMj C.60stfuS tiwh . DiBrri ri inches. Total depth, feet. Type of casting, Depth of casting. feet Ap ..11iati.ii {e;deptfh to puinping level of water in well, feet.- Appro:drnate yield, gallons per minute. SEWatartight to depth of feel pacl3 aroelnd casting sealed with: ❑ Cement grout ❑ Puddled day ❑ Ord'uhary bacldff. V1(eIi oak �`� [Concrete. +U*wd ❑ Metal. Openings in well cover watertight: ❑ Yes ❑ No. Pump:: aS�Flallov+►weit ❑ Deep wall Length of drip pipe, fast` Pump capacity, gallons per minute Located fn � Basement . ❑ Pumproom off baseinerd ❑ Pumphouse above'1 ❑ Pump 'plL Pumprcjorih prop.W drained: ❑ Yes ❑ No. -Frmp mounting Watertight: ❑ Yes ONO. Type of stotage: ❑ Pressure 0 Gravity. Capadty, gallons. Has bacteriological examination of water been made? []Yes ❑ No. g answer WNW give date , apafty'of water ❑ is ❑ Is not satisfactory for human consumption. installation ❑ does ❑ does not comply with approved exhibits , if any. Inspection made by: Slate ❑3 County ❑ bake! Health Authority. Inspeded by Dale ofinsp"ecfoi"r City of La Quinta 78-495 Calle Tampico La Quinta, CA 92253 ATTN: AJ Ortega Re: Slifer Residence 78-023 San Timoteo Plan Check #BRES 2018-01 19 Dear AJ, May 9, 2018 Please refer to the enclosed response lists regarding the corrections for 78-023 San Timoteo. Per our telephone conversation we have defined the scope of work on the cover sheet and have revised the site plan to show the extent of the addition of the service room and bedroom extension. We have shown an existing floor plan to help clarify what is existing and what is new. There are no new fixtures being added to the existing septic tank. Any further questions you may have please let me know. Sincerely, STRACTS, Inc. Anton Marinkovich President (760) 636.8951 STRACTSINC ARCHITECTURE + INTERIOR DESIGN RECEIVED MAY 10 2018 CITY OF LA QUINTA COMMUNITY DEVELOPMENT 550 S. OLEANDER ROAD I PALM SPRINGS, CA 92264 1 PHONE 760.636.8951 1 FAX 760.778.1314 RT/--...L� YOUR LIFE. YOUR FIRE. ORTAL Heating Solutions Ltd. INSTALLATION & OPERATION MANUAL The ORTAL direct vent (and ORTAL power vent with separate manual) gas appliances have been tested and approved by CSA for safety .and efficiency for use with either Natural Gas (NG) or Propane (LPG). Standard references: ANSI Z21.88/CSA 2.33-2014- Vented Gas Fireplace Heaters CLASS 2901 84 — DOMESTIC HEATERS (GAS) Vented Fireplace — Certified to US Standard CLASS 290104 — DOMESTIC HEATERS (GAS) Vented Fireplace Pictured Above: ORTAL's Clear 110 TS Patent Pending for screen barrier glass bracket: USSN 60/040,074 Version: February 24, 2015 MAY 10 2018 CITY OF LA QUINTA COMMUNITY DEVELOPMENT SUBJECT DETAILS TYPE OF GAS Natural Gas (NG) or Propane (LPG) VENT 4/6" or 5/8" Direct Vent HEAT BARRIER Screen (standard) or Double Glass (optional) INTERIOR DESIGN MEDIA Wood Style Log Set with Embers: Charred Oak Clay Logs Split Oak Ceramic Fiber Logs Driftwood Logs Mixed Long and Short Branches with Embers Ceramic Fiber Stones Colors: Grey or White Size: Large or Small Polished Ceramic Glass Colors: Amber, Black, Blue and Clear General Note Leave 20% of burner and grill uncovered by media WEIGHT - Clear 40H70 206 lbs. Clear 60x80 319 lbs. Clear 75x65 358 lbs. Clear 75 378 lbs. Clear 110 383 lbs. Clear 110H 440 lbs. Clear 130 375 lbs. Clear 130H 450 lbs. Clear 150 590 lbs. Clear 150H 767 lbs. 26 SUBJECT DETAILS WEIGHT Clear 200 534 lbs. Clear 2O0H 580 lbs. Clear 250 621 lbs. Clear 25OH 807 lbs. STANDARD Safety ANSI Z21.88/CSA 2.33-2014 Efficiency ANSI P.4.1-09 OPERATION Mertik Maxitrol Remote Control (full automatic, wall control unit is optional), electronic ignition ELECTRICAL REQUIREMENTS All models are provided with an AC adapter which requires a 110 volts 20-amp outlet. Double Glass and Power Vent features require an additional 2nd and 3rd outlet. Product Specifications The fireplace has been certified for use with either Natural Gas (NG) or Liquefied Petroleum (LPG). All Ortal fireplaces operate with a direct vent, balanced flue venting system. A direct vent gas fireplace is room -sealed by a glass front. The flue uses natural ventilation to pull air in from and release exhaust gases to the outside. Refer to manual for clearance distances. Installation is recommended in living spaces such as bedrooms, living rooms, etc. The fireplace must be properly connected to a venting system. The fireplace must be installed according to Ortal USA requirements in addition to any local codes that may apply. If none existent, then the current CSA installation code must be followed: USA, ANSI Z223.1/NFPA 54 Canada, CSA B149 27 I BUILDING ENERGY ANALYSIS REPORT PROJECT: Slifer Residence 78-023 San Timoteo La Quinta, CA 92253 Project Designer: Stracts Architecture + Interior Design 550 S. Oleander Palm Springs, CA 92264 (760) 636-8951 Report Prepared by: Jon d. Scott Scott Design and Title 24, Inc 74818 Velie Way Suite 8 Palm Desert, CA 92260 (760) 200-4780 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION Job Number: Date: 5/23/2018 -P-a Ica - 0% 1 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has: approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. I TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01-E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 11 Form MF-1 R Mandatory Measures Summary 12 HVAC System Heating and Cooling Loads Summary 16 Zone Load Summary 17 Room Load Summary 18 Room Heating Peak Loads 19 Room Cooling Peak Loads 21 EnergyPro 7.2 by EnergySoft Job Number ID: User Number: 6712 CERTIP : OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE F )D Project Name: Slifer Residence Calculation Date/Time: 14:19, Wed, May 23, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4EB9.tmp.xml CF1 F-01 Page 1 of 8 GENERAL INFORMATION 01 Project Name Slifer Residence 02 Calculation Description Title 24 Analysis 03 Project Location 78-023 San Timoteo 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.0 (1016 SP2) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 0 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 4467 15 Number of Zones 2 16 Slab Area (ft2) 4467 17 Number of Stories 1 18 Addition Cond. Floor Area (ft2) 371 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 371 21 Glazing Percentage (%) 18.2% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 4.29 3.47 0.82 19.1% Space Cooling 156.53 156.66 -0.13 -0.1% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 5.09 5.09 0.00 0.0% Photovoltaic Offset -- 0.00 0.00 — Compliance Energy Total 165.91 165.22 0.69 0.4% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. NO SPECIAL FEATURES REQUIRED Registration Number: Registration DateRme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-05-23 14:19:58 CERTIFI "OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE F )D Project Name: Slifer Residence Calculation Date/Time: 14:19, Wed, May 23, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4EB9.tmp.xml CF1 F-01 Page 2 of 8 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • --None— Cooling System Verifications: • -- None -- HVAC Distribution System Verifications: • -- None -- Domestic Hot Water System Verifications: • -- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Slifer Residence 4467 1 4 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 addition Conditioned HVACex1 371 11.3 DHW Sys 1 n/a existing residence Conditioned HVACex1 4096 11.3 DHW Sys 1 n/a Registration Number: Registration DateRme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-05-23 14:19:58 CERTIF : OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I )D Project Name: Slifer Residence Calculation Date/Time: 14:19, Wed, May 23, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4EB9.tmp.xml CF1 F-01 Page 3 of 8 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition N Wall addition R-21 Wall 0 Front 101 20.1 90 New n/a E Wall addition R-21 Wall 90 Left 101 0 90 New n/a S Wall addition R-21 Wall 180 Back 101 0 90 New n/a W Wall addition R-21 Wall 270 Right 306 16.5 90 New n/a Interior Surface addition»existing residence interior Wall 186 0 New n/a N wall 2 existing residence default Wall 0 Front 860 118 90 Existing No E wall 2 existing residence default Wall 90 Left 620 165.8 90 Existing No S wall 2 existing residence default Wall 180 Back 860 327 90 Existing No W wall 2 existing residence default Wall 270 Right 620 165 90 Existing No Interior Surface 2 existing residence>>addition default Wall 388 0 Existing No Roof 2 existing residence Defaul: 1978 to present 4096 Existing No OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 11 12 13 Name Zone Type Orientatio n Area (ft) Skylight Area (ft2) Roof Rise (x in 12) Roof Pitch Roof Tilt(deg) Roof Reflectan ce Roof Emittance Framin g Factor Status Verified Existing Condiflon Roof addition R-38 Roof Attic Front 371 0 0 0 0 0.1 0.85 0.1 New n/a ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic existing residence Attic Roofexisting residence Ventilated 1 0.1 0.85 No No Existing No Registration Number: Registration Dateffime: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-05-23 14:19:58 CERTIF °- OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I )D Project Name: Slifer Residence Calculation Date/Time: 14:19, Wed, May 23, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4EB9.tmp.xml CF1 F-01 Page 4 of 8 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft) U-factor SHGC Exterior Shading Status Verified Existing Condition Window N Wall (Front-0) - -- 1 20.1 0.35 0.36 Insect Screen (default) New n/a Window 2 W Wall (Right-270) -- -- 1 10.5 0.35 0.36 Insect Screen (default) New n/a Window 3 W Wall (Right-270) -- - 1 6.0 0.35 0.36 Insect Screen (default) New n/a Window 4 N wall 2 (Front-0) - - 1 64.0 0.35 0.36 Insect Screen (default) New n/a existing window door slid N wall 2 (Front-0) - - 1 24.0 0.71 0.60 Insect Screen (default) Existing No existing window door slid 2 N wall 2 (Front-0) - -- 1 30.0 0.71 0.60 Insect Screen (default) Existing No existing window door slid 3 E wall 2 (Left-90) - - 1 40.0 0.71 0.60 Insect Screen (default) Existing No existing window door slid 4 E wall 2 (Left-90) -- -- 1 24.0 0.71 0.60 Insect Screen (default) Existing No existing window door slid 5 E wall 2 (Left-90) -- -- 1 12.5 0.71 0.60 Insect Screen (default) Existing No existing window door slid 6 E wall 2 (Left-90) -- -- 1 12.5 1 0.71 0.60 Insect Screen (default) Existing No Window 5 E wall 2 (Left-90) -- -- 1 13.8 0.35 0.36 Insect Screen (default) New n/a existing window door slid 7 E wall 2 (Left-90) - - 1 15.0 0.71 0.60 Insect Screen (default) Existing No existing window door slid 8 E wall 2 (Left-90) - -- 1 48.0 0.71 0.60 Insect Screen (default) Existing No Window 6 S wall 2 (Back-180) - -- 1 64.0 0.35 0.36 Insect Screen (default) New n/a Window 7 S wall 2 (Back-180) - - 1 44.0 0.35 0.36 Insect Screen (default) New n/a existing window door slid 9 S wall 2 (Back-180) -- -- 1 24.0 0.71 0.60 Insect Screen (default) Existing No Window 8 S wall 2 (Back-180) -- -- 1 96.0 0.35 0.36 Insect Screen (default) New n/a existing window door slid 10 S wall 2 (Back-180) - - 1 24.0 0.71 0.60 Insect Screen (default) Existing No existing window door slid 11 S wall 2 (Back-180) - -- 1 15.0 0.71 0.60 Insect Screen (default) Existing No existing window door slid 12 S wall 2 (Back-180) - -- 1 15.0 1 0.71 0.60 Insect Screen (default) Existing No existing window door slid 13 S wall 2 (Back-180) - - 1 15.0 0.71 0.60 Insect Screen (default) Existing No existing window door slid 14 S wall 2 (Back-180) -- - 1 15.0 0.71 0.60 Insect Screen (default) Existing No existing window door slid 15 S wall 2 (Back-180) -- -- 1 15.0 0.71 0.60 Insect Screen (default) Existing No Window 9 W wall 2 (Right-270) -- - 1 6.0 0.35 0.36 Insect Screen (default) New n/a existing window door slid 16 W wall 2 (Right-270) - - 1 64.0 0.71 1 0.60 Insect Screen (default) Existing No existing window door slid 17 W wall 2 (Right-270) - -- 1 12.5 0.71 0.60 Insect Screen (default) Existing No existing window door slid 18 W wall 2 (Right-270) - -- 1 12.5 0.71 0.60 Insect Screen (default) Existing No existing window door slid 19 W wall 2 (Right-270) -- -- 1 18.0 0.71 0.60 Insect Screen (default) Existing No Registration Number: Registration Dateffime: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-05-23 14:19:58 CERTIF °- OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE F )D Project Name: Slifer Residence Calculation Date/Time: 14:19, Wed, May 23, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4EB9.tmp.xml CF1 F-01 Page 5 of 8 existing window door slid 20 W wall 2 (Right-270) -- -- 1 40.0 0.71 0.60 Insect Screen (default) Existing No Window 10 W wall 2 (Right-270) — — 1 12.0 0.35 0.36 Insect Screen (default) New n/a OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Inside Finish: Gypsum Board • Cavity/Frame: R-30/2x10 • Roof Deck: Wood Siding/sheathing/decking R-38 Roof Attic Cathedral Ceilings Wood Framed Ceiling 2x10 @ 16 in. O.C. R 30 0.037 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Cavity / Frame: no insul. / 2x4 interior Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.277 Other Side Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofexisting residence Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Defaul: 1978 to present attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 11 0.083 Over Ceiling Joists: R-1.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-11 /2x4 default Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 11 0.110 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Cavity/Frame: R-11 /2x4 default Wall Interior Walls IWood Framed Wall 2x4 @ 16 in. O.C. R 11 0.099 Other Side Finish: Gypsum Board SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value Carpeted Fraction Heated Status Verified Existing Condition Slab -on -Grade addition 371 0.07 None 0.8 No New No Slab -on -Grade 2 existing residence 4096 186 None 0.8 No Existing No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-05-23 14:19:58 CERTIF : OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I )D Project Name: Slifer Residence Calculation Date/Time: 14:19, Wed, May 23, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4EB9.tmp.xml CF1 F-01 Page b of 8 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 0 Existing No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Input Rating / Tank Standby Heater Tank Uniform Energy Pilot / Insulation Loss I First Hour Tank Location Element Number Volume Factor / Energy Thermal R-value Recovery Rating / NEEA Heat Pump or Ambient Name Type Tank Type of Units (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Brand / Model Condition DHW Heater 1 Gas Small Storage 1 1 50 1 0.61 EF 140,000 Btu/hr 0 n/a n/a I n/a I n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Status Verified Existing Condition HVACex1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Existing No HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R-value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not System 1 (Ventilated and specified) 8.0 Attic Attic None Existing No Na Unventilated) Registration Number: Registration DatefTime: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-05-23 14:19:58 CERTIP : OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE N )D Project Name: Slifer Residence Calculation Date/Time: 14:19, Wed, May 23, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4EB9.tmp.xml CF1 F-01 Page 7 of 8 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 0.25 Default 0 Not Required Registration Number: Registration Datemme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-05-23 14:19:58 CERTIF = OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I DD Project Name: Slifer Residence Calculation Date/Time: 14:19, Wed, May 23, 2018 Calculation Description: Title 24 Analysis Input File Name: tmp4EB9.tmp.xml CF1 F-01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Jon d. Scott Jon d. Scott Company: Signature Date: 5-23-18 Scott Design and Title 24, Inc, 5/23/2018 pc Corr Address: CEA/HERS Certification Identification (If applicable): 74818 Velie Way Suite 8 city/Stat I .1m Desert, CA 92260 Phone: (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Stracts Architecture + Interior Design Company: Date Signed: Stracts Architecture + Interior Design Address: License: 550 S. Oleander City/State/Zip: Palm Springs, CA 92264 Phone: (760) 636-8951 Registration Number: Registration Date[Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-05-23 14:19:58 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Slifer Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family 0 Existing+ Addition/Alteration Date 5/23/2018 Project Address 78-023 San Timoteo La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,467 Addition 371 # of Units 1 INSULATION Construction Type Cavity Area ffz Special Features Status Roof Wood Framed Rafter R 30 371 New Wall Wood Framed R 21 572 New Slab Unheated Slab -on -Grade - no insulation 371 Perim = 0' New Demising Wood Framed - no insulation 186 New Roof Wood Framed Attic R 11 4,096 Existing Wall Wood Framed R 11 2,572 Existing Slab Unheated Slab -on -Grade - no insulation 4,096 Perim = 186' Existing FENESTRATION I Total Area: 812 Glazing Percentage: 18.2% New/Altered Average U-Factor: 0.35 Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades Status Front (N) 84.1 0.350 0.36 none none Bug Screen New Right (W) 34.5 0.350 0.36 none none Bug Screen New Front (N) 54.0 0.710 0.60 none none Bug Screen Existing Left (E) 152.0 0.710 0.60 none none Bug Screen Existing Left (E) 13.8 0.350 0.36 none none Bug Screen New Rear (S) 204.0 0.350 0.36 none none Bug Screen New Rear (S) 123.0 0.710 0.60 none none Bug Screen Existing Right (W) 147.0 0.710 0.60 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Cooling Duct Duct Location R-Value Status HVACex Ducted Ducted Attic 8.0 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnerqvPro 7.2 by EnerqySoft User Number: 6712 ID: Page 11 of 24 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. *Exceptions may apply. un inai Udr1U1b Building Envelope Measures: § 110.6(a)l: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per NFRC-400 or ASTM E283 or AAMAIWDMA/CSA 101II.S.2/A440-2011: § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-B for compliance and must be caulked and/or weatherstried.' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of 110.8 i when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.* § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or § 150.0(c): less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.* § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). § 150.0(g)1: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d). § 150.0(g)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)lA: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)1C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.* § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.' § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.* Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool and spa heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; orACCA Manual J using design conditions specified in 4 150.0(h)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures' § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution pipinq for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m 11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of § 150.0(m)12. a2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RAU. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating! § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fanspeed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k).' Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 ; and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 ; and all other requirements in § 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways! § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0 k 3A or with the applicable requirements in 110.9,130.0, 130.2, 130.4,140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B or 4 150.0 k 3D must comply with the applicable requirements in §§ 110.9,130.0,130.2,130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 wafts of power as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9,130.0,130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.1 0b through § 110.10 e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.* Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 110.1 0c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Slifer Residence Date 5/23/2018 System Name HVACex Floor Area 4,467 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 4,263 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 81,732 5,783 1,758 63,240 Total Output Btuh 89,000 0 Output Btuh/s ft 19•9 4,718 3,108 Cooling System 0 0 Output per System 35,500 0 0 0 0 Total Output Btuh 35,500 0 5,783 0 Total Output Tons 3.0 4,718 3,108 Total Output Btuh/s ft 7.9 Total Output s ft/Ton 1,510.0 1 91,169 F 69,456 Air System CFM perSystem 1,400 HVAC EQUIPMENT SELECTION Airflow cfm 1,400 HVAC 26,499 3,996 89,000 Airflow cfm/s ft 0.31 Airflow cfm/Ton 473.2 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 26,499 3,996 89,000 Outside Air cfm/s ft 0.00 Jan 1 AM Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF 105 OF 105 OF Outside Air 0 cfm Heating Coil Supply Fan 1,400 cfm 69 OF Return Fan 69 OF 1,400 cfm 104 o F ROOM 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF 77/63OF 55/54OF 55/54OF Outside Air 0 cfm Cooling Coil Supply Fan 1,400 cfm Return Fan 77 / 63 OF 77 / 63 IF ® 1,400 cfm ` 57 / 55 OF 48.9% ROOM 75 / 62 OF I EnergyPro 7.2 by EnergySoR User Number. 6712 ID: Page 16 of 24 'ZONE•AD SUMMARY Project,-. Residence 512312018 System Name HVACex FloorSlifer 4. ZONE LOAD ZONAL SYSTEM .. SYSTEM NAME existing residence LOAD) EnergyPro ROOM LOAD SUMMARY Project Name Date Slifer Residence 512312018 HVACex 4,467 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible addition additions 78-023 San Tim 1 241 4,626 480 241 4,626 480 90 3,431 existing residence 78-023 San Timoteo 1 1 4,022 77,107 5,303 4,022 77,107 5,303 1,668 59,809 PAGE TOTAL TOTAL' 4,263 81,7321 5,7831 1,7581 63, 240 4,2631 81,7321 5,7831 1,7581 63, 240 Total includes ventilation load for zonal systems. EnergyPro 7.2 by EnerqySoft User Number: 6712 ID: Page 18 of 24 ROOM HEATING PEAK LOADS Project Name Slifer Residence Date 512312018 ROOM INFORMATION DESIGN CONDITIONS Room Name additions 78-023 San Timoteo Floor Area 371.00 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF 0 = = c = = = = = = = = = = = = = = = = = = = = = = = 42 Btu/hr R-38 Roof Attic 371.0 0.0360 42 561 R-21 Wall 572.4 0.0690 42 1,659 slider windows Door ..35/.36 36.6 0.3500 42 538 Slab -On -Grade penim = 0.1 0.7300 42 2 `interior Wall 186.0 0.3560 -2 -132 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 371 X Area another room 11.30 X 0.257 Height ACH Page Total / 60 ] X AT Z628 = 803 TOTAL HOURLY HEAT LOSS FOR ROOM 3,431 EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 19 of 24 ROOM BEATING PEAK LOADS Project Name Slifer Residence 75/23/2018 Date ROOM INFORMATION DESIGN CONDITIONS Room Name 78-023 San Timoteo Floor Area 4,096.00 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U-Value X 0.0790 X 0.1100 X 0.3500 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr Default 1978 to present 4,096.0 44 14,238 default Wall 2,184.2 44 10,572 slider windows Door ..35/.36 299.8 44 4,617 Existing Window 476.0 X 0.7100 44 14,870 Slab -On -Grade perim = 186.0 X 0.7300 44 5,974 *default Wall 388.0 X 0.1100 2 85 X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (*) denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 4,096 X Area to another room 11.30 X 0.262 Ceiling Height ACH Page Total / 60 ] X AT 50,356 = 9,453 TOTAL HOURLY HEAT LOSS FOR ROOM 59,809 EnergyPro 7.2 by EnergySoft User Number.- 6712 ID: Page 20 of 24 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Slifer Residence 5/23/2018 ROOM INFORMATION DESIGN CONDITIONS Room Name additions 78-023 San Timoteo Outdoor Dry Bulb Temperature 112 OF Floor Area 371.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range. 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof Attic (N) 371.0 X 0.0360 X 56.0 = 748 R-21 Wall (N) 80.9 X 0.0690 X 23.0 = 128 R-21 Wall (E) 101.0 X 0.0690 X 33.0 = 230 R-21 Wall (S) 101.0 X 0.0690 X 26.0 = 181 R-21 Wall (W) 289.5 X 0.0690 X 33.0 = 659 'interior Wall 186.0 X 0.3560 X 0.0 = 0 X X = X X = X J X = Page Total 1,947 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (N) 0.0 X 20.4 + 20.1 X 20.4 = 409 Window (W) 0.0 X 20.4 + 10.5 X 41.7 = 438 Window (W) 0.0 X 20.4 + 6.0 X 41.7 = 250 X + X = X + X = X + X = X + X = X + X = X +1 ix = Page Total 1,098 Internal Gain Btu/hr Occupants 11 Occupants X 245 Btuh/occ. = E:A Equipment 371 Floor Area X 0.50 w/sgft = Infiltration: 1.064 X 0.89 X 19.21 X 37 = 675 Air Sensible CFM ELA 4T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 4,626 Latent Gain Btu/hr Occupants 11 Occupants X 155 Btuh/occ. = 173 Infiltration: 4,771 X 0.89 X 19.21 X 0.00376 = 308 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 173 EnergyPro 7.2 by EneriqySoft User Number: 6712 ID: Page 21 of 24 RESIDENTIAL ROOM COOLING LOAD SUMMARY rrolect Name Date Slifer Residence 512312018 ROOM INFORMATION. DESIGN CONDITIONS Room Name 78-023 San Timoteo Outdoor Dry Bulb Temperature 112 OF Floor Area 4,096.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Ranue: 34 OF Opaque Surfaces Defaul: 1978 to present default Wall default Wall default Wall default Wall -default Wall Orientation (N) (N) (E) (S) (W) Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = = = 4,096.0 0.0790 56.0 742.0 0.1100 23.0 454.2 0.1100 33.0 533.0 0.1100 26.0 455.0 0.1100 33.0 388.0 0.1100 0.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window existing window door slider existing window door slider existing window door slider existing window door slider existing window door slider existing window door slider Window existing window door slider Orientation (N) (N) (N) (E) (E) (E) (E) (E) (E) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = - 0.0 20.4 64.0 20.4 0.0 36.5 24.0 36.5 0.0 36.5 30.0 36.5 0.0 36.5 40.0 72.1 0.0 36.5 24.0 72.1 0.0 36.5 12.5 72.1 0.0 36.5 12.5 72.1 0.0 20.4 13.8 41.7 0.0 36.5 15.01 1 72.1 Page Total Btu/hr 18,121 1,877 1,649 1,524 1,6521 0 24,823 Btu/h r 1,303 875 1,094 2, 883 1,730 901 901 576 1,081 11.345 Internal Gain Btu/hr Occupants 12.3 Occupants X 245 Btuh/occ. = 3,014 Equipment 4,096 Floor Area X 0.50 w/sgft = 6,990 Infiltration: 1.064 X 0.89 X 212.12 X 37 = 7,454 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 77,1071 Latent Gain Btu/hr Occupants 12.3 Occupants X 155 Btuh/occ. = 1,907 Infiltration: 4,771 X 0.89 X 212.12 X 0.00376 = 3,396 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1.9071 of 24 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Slifer Residence 5/23/2018 ROOM INFORMATION DESIGN CONDITIONS Room Name 78-023 San Timoteo Outdoor Dry Bulb Temperature 112 OF Floor Area 4,096.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 °F Outdoor Daily Ranqe: 34 OF Surfaces Orientation Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = = = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) FPnP_Stratinn existing window door slider Window Window existing window door slider Window existing window door slider existing window door slider existing window door slider existing window door slider r)riantatinn (E) (S) (S) (S) (S) (S) (S) (S) (S) Shaded Unshaded Area X X X X X X X GLF + + + + + + + Area X X X X X X X GLF = = = = = = = 0.0 36.5 48.0 72.1 0.0X 20.4+ 64.0X 20.4= 0.0 20.4 44.0 20.4 0.0 36.5 24.0 36.6 0.0 20.4 96.0 20.4 0.0 36.5 24.0 36.6 0.0 36.5 15.0 36.6 0.0 36.5 15.0 36.6 0.0X 36.5+ 15.0X Page Total Btu/hr Btu/h r 3,460 1,308 9001 I� 879 1,963 879 549 549 549 11.035 internal uain Btu/hr Occupants 12.3 Occupants X 245 Btuh/occ. = 3,014 Equipment 4,096 Floor Area X 0.50 w/sgft = 6,990 Infiltration: 1.064 X 0.89 X 212.12 X 37 = 7,454 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 77,1071 Latent Gain Btu/hr Occupants 12.3 Occupants X 155 Btuh/occ. = 1,907 Infiltration: 4,771 X 0.89 X 212.12 X 0.00376 = 3,396 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1.9071 24 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Slifer Residence 5/23/2018 ROOM INFORMATION DESIGN CONDITIONS Room Name 78-023 San Timoteo Outdoor Dry Bulb Temperature 112 OF Floor Area 4,096.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Ranqe: 34 OF ue Surfaces Orientation Area U-Factor CLTD' X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fenestratinn existing window door slider existing window door slider Window existing window door slider existing window door slider existing window door slider existing window door slider rd ng window door slider ow Orientatinn Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = - = 0.0 36.5 15.0 36.6 0.0 36.5 15.0 36.6 0.0 20.4 6.0 41.7 0.0 36.5 64.0 72.1 0.0 36.5 12.5 72.1 0.0 36.5 12.5 72.1 0.0 36.5 18.0 72.1 0.0 36.5 10.01 72.1 0.0 20.4 12.0 41.7 Page Total Btu/hr Ul Btu/hr 549 549 250 4,614 901 901 1,298 2,883 501 12.446 Internal Gain Btu/hr Occupants 12.3 Occupants X 245 Btuh/occ. = 3,014 Equipment 4,096 Floor Area X 0.50 w/sgft = 6,990 Infiltration: 1.064 X 0.89 X 212.12 X 37 = 7,454 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 77,1071 Latent Gain Btu/hr Occupants 12.3 Occupants X 155 Btuh/occ. = 1,907 Infiltration: 4,771 X 0.89 X 212.12 X 0.00376 = 3,396 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,907 User