Loading...
Alta Verde - Coral Mountain TR 34243 (Phase 2, 3 & 4)Bin ff I I C Permit # '11 (0 P.O. 1 La Quir Building Perm �C Project Address: u0 ; 34243 A. P. Number: W"R-InOONTAIN r1I-Jfr-176M Po .16 Contractor: Atf - I/Mry But W6 ,-pW Address: 7/-qe43 f1I&4jwe11 rrl SuIM 6-.. City, ST, Zip: 40 Ml rZA*f 27, dt Telephone: 0 r 1 77b fill State Lic- # : City Lic. # Arch., Engr., Designer: Address: City, ST, Zip: Telephone: StateLi Name of Contact Person: ri►' ............. tkol� # of Contact Person:(310—) 277-99'55 dTelephone �`�SEIl. 1b0.1�p. �D01 APPLICANT: DO NOT W # Submittal Req'd Ree'd TRA, Plan Sets di Plan Check submitted Structural Calcs. rn� Reviewed, ready for corn Calcs. Called Contact Person JTruss Title 24 Calcs. 5 Plans picked up Flood plain plan Plans resubmitted Grading plan 2nd Review, ready fo orr Subcontactor List Called Contact Person Grant Deed Plans picked up H.O.A. Approval Plans resubmitted IN HOUSE:- Review, ready for corr, Planning Approval Called Contact Person Pub. %Vks. Appr Date of permit issue School Fees �d(a I7oi2- f�Pvt�c�-may 5��-r,r� it�e�3utur t4s W-C IftAn avv 'rb *VCUC600 ►ty of La Quinta Building 81• Safety Division ox 1504, 78-495 Calle Tampico ta, CA 92253 - (760) 777-7012 it Application and Tracking Sheet wner's Name: AptoR Address: SA4VM— � City, ST, zip: elephone: ..................::: Project Description: Cd NS 1VL4 CI10a o F gEW D"AW 6-1 - I f ft fla- P-ell19&4xi 01¢ ,f/M1L CIAW AND FlN(S{'( V'l �77o N f . �d 06 Construction T n Type:fqP6 V — Occupancy: anc P Y Project type (circle one): New Add'n Alter Repair Demo Sq.#Stories: 1 #Units: Estimated Value of Project: SITE BELOW THIS LINE KING PERMIT FEES Amount ctionsr(4 794 gpn- Ian Check Deposit Plan Check Balance Construction �Q •" L� Mechanical ti s/issu Electrical - Plumbing S.M.I. Grading etio /issue eveloper Impact Fee A.I.P.P. Total Permit Fees It ISO 1"el- r S.1—sT j a�C. a s EsGil Corporation In (Partnership with Government for Building Safety DATE: 8/1/2012 .[3—AEELICANT JURI . JURISDICTION: City of La Quinta ❑ LAN REVIEWER ❑ FILE PLAN CHECK NO.:. 127716 ' SET: I PROJECT ADDRESS: Alta Verde Coral Mountain PROJECT NAME: Coral Mountain 2010 Code Structural Update Only ® The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. ' ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ❑ The applicant's copy of the check list has been sent to: Z EsGil Corporation staff did not advise the applicant that the plan check has been completed. ❑ EsGil'Corporation staff did -advise the applicant that the plan check has•been completed. Person contacted: Telephone #: Date contacted:. (by: ) Email:: Fax #: Mail Telephone Fax In Person ® REMARKS: EsGil Corporation did not perform the original review for this project. Per the . Building Official's direction, we have only verified code compliance with the 2010 code structural update. By: David Yao Enclosi EsGil Corporation. ❑ GA ❑ EJ ❑ PC 7/26 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California T � 000 ToWIT n AU fi 022012 IUI HiAUG 0,t2012 By Fax (858) 560-1576 Bulliitrip Permit Number -> ProjtjttDescrip�an� Mufd'SFRs "- (Materials may oontatn hua vyagtes and are rmt subject to iacyc9o9 pmvielone) Construdtlon DebHsFManagPlan Pidn bubanittal De ` :=74012' Jodi to AddrbwMadOon /, 58ttt owna'a Nan AV Construction,, OBA Alta V®nie Coial Mtti, LLC Number, street rn RO ' 71905 Hwy 411;, Unit G cny state; Poat+� c i : Rancmo;Mhage, CA OWd t7wner'a Phone N� • • Ownefa.C^=Med1AdV r _ 4,, 't,� act Mem Nam RusseQ° 'j ` r Project Menager'd:Phone ' rl•7..80-200$g07 'isaderlContrecM 'AbYerde Builders Number, sheet rn Pa 71905 Hwy 111,lufi t G , city; state, PoaW ' Randto.MUage; Ckq?70,, ` P,ro]ect square Footsg .2011,000' �6 s Date of Mh►ArNfwrai ...- . Matert6161d'S i01scanded - � 2 F` Trash . > :381t90 f�tot recyclable Product ', Tofu • ,+� At7 r 'r, a-. ..tr �=' �'RF'i "4 •x r� eMason tirolaen0:00 tir p Re"ryda6i i { -�BdWB16d ,O:w Recyda a Plaster 74020 Cardarid 166:33 Reoyelabte ` StxaP'Metai , t0: 0 { ` < Comm�ln&l -_ °000 t odydebre L °Tile (floor), i" 3417 4 - _ 1 Canaeie a1808 Recyclable:b9(mof) * "I0' Reryctebi Drywall Rscyetab'' ">ow F 50 5 Rxyow- �y `Donated'/ t�Use ; : _ �Oi00 e' ' "` 'Le�1dSCepe'Deb1iS' 10 00 ReajieW- - - . •DBacrtbe+IiemB j - __ a `� a;. ��, .•.. _ - R�-. �,,. .'� c � f •--�.. ter` -�aa+s -f -a Z _ .{� ��.- s � . ra- Tota1S"`� 'R de sTraah ., ProjededDhreralttin. � :� : �, �g7a1,1 � ,�`x"z381�9 " • �'; „' ':� � {`� � a6S.TK y} ' pry • A contractor ee of the property ay 9;: all retUae material from JI pone�l9y foi erie�ulnp that Utp proWatorre of the DMP ate edf ie opt Informed of the d6raton progrow througa-inorittilyroporta.:lf e tiska_ i to an a�iroved recycter or trarudm atetton. '.. SIa����aa� • . co.nsulting:group, inc. _ r .ENERGY.CALCULATION (T-24) �- - r - (ResiilentiahDevelopment) _ x :.. 'Coral: Mountain La Quinta, County of Riverside, CA { 'Gouvisj6b No. 62649. . _ 1 /912013 ,. Developer. a Alta ver'de Builders - q .. Architect `" Poon Design Inc CITYft F A'JQUINTAT 4 F r DEPT x BUILDING &-SAFETY PP0. , FOD`',CONSTRUCTiO >1 1 LDATI��� Ka w l x pf ESSI a ��Q`�► ..q�G.0 .- jy�G * . -_, -yam • � q 949.752.1612' ................. �._� 4400 Campus Drive Gangyi Zhou; _ .Newport -Beach, M34279 Ex" pDate:I2/31'/2014', .] The attachedcalculations are valid only when bearing.,original. or California electronic signature .of Gangyi Zhou,"Hereon: ' 92660 T { ..www.gouvisgroup:com Palm Springs, CA Pleasanton,'CA Ho, Chi Minh City, Vietnam r BUILDING ENERGY ANALYSIS REPORT PROJECT: CORAL MOUNTAIN - PLAN C LA QUINTA, CA Project Designer: POON DESIGN INC '315 S. Beverly Drive, Suite 206 Beverly Hills, CA 90212 310-277-8855 -Report Prepared by: Gangyi Zhou GMEP Engineers " 4400 Campus Drive Newport Beach, CA 92660 9497521612 .. pROFESs1 O Job Number: A+13 .zm. 62649 �� ExP is ANlc Date: OFCAlIFORN�P 1 /2/2013 The EnergyPro computer program has been used to perform the, calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro5.1 by Energ Soft User Number. 8165 RunCode:2013-01-02T15:54:43 ID: 62649 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 F� Mandatory Measures Summary 10 Form UTIL-1 R Utility Incentive Worksheet 13 EnergyPro 5.1 by EnergySoft Job Number: ID: 62649 User Number: 8165 Electrronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name CORAL MOUNTAIN - PLAN C Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,849 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (e) Features (see Part 2 of 5) Status Wall Wood Framed R-21 3,405 New Wall Wood Framed R-19 149 Ext=R-4.0 New Roof Wood Framed Rafter R-38 2,849 New FENESTRATION U- Exterior Orientation Area(fe) Factor SHGC Overhang Sidefins Shades Status Right (S) 40.6 0.290 0.33 none none Roll -down Blind or Slats New Right (S) 141.0 0.290 0.29 none none Roll -down. Blind or Slats New Front (W 72.6 0.290 0.33 none none Roll -down Blind or Slats New Rear (E) 68.4 0.290 0.33 none none Roll -down Blind or Slats New Rear (E) 22.0 0.320 0.28 none l none Roll -down Blind or Slats New Rear (E) 56.4 0..290 0.29 none. none Roll -down Blind or Slats New Front (W) 28.2 0.290 0.29 none none Roll -down Blind or Slats New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status 3.5T Carrier Ducted Ducted Conditioned 6.0 New 2.5T Carrier Ducted Ducted Conditioned 6.0 New 1.5T Carrier Ducted Ducted Conditioned 6.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Instant Gas 0 0.84 Kitchen Pipe Ins New Enery Pro 5.1 by Energ Soft User Number: 8165 RunCode: 2013-01-02T15:54:43 ID: 62649 Page 1 of 7 Reg: 212-N0070417B-000000000-0000 Registration Date/Time: 2012/12/13 18:31:00 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013� Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN'- PLAN C Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. - , a ' R J� E HERS, REQUIRED/1/ERIFICATION E y} �' 4' Items in this section require field testing`and/or verification` by a certified HER&Rater.—The inspector -most receive a completed CF-4R form for each of the measures listed below for final to be given. ' The Cooling System Bryant 315JAV048090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the ondenser. C System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. rTheHVAC ce credit for quality installation of insulation has been used. HERS field verification is required. System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. ' The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. t The Cooling System Bryant 315JAV036070 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. ' The HVAC System 2.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 2.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 2.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 2.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro 5.1 by EnerqySoft User Number: 8165 RunCode: 2013-01-02T15:54:43 ID: 62649 Page 2 of 7 Reg: 212-N0070417B-000000000-0000 Registration Date/Time! 2012/12/13 18:31:00 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 ' Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN C Building Type - ® Single Family ❑ Addition Alone ❑ Multi!Family ❑ Existing+ Addition/Alteration Date 1/3/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist.. These items require special written . justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. ,/�",_ _"�'ti' .,$))-•-°7 .,� - -�, -.{,=tom..=� , W:,; ��-,,,�r� ��-«. --•; F �r-�-.��: HERS REQUIRED YERIFICATION + Items in this section require field testi'ng'and/or.verificat on'by'a certified HERS Rater 'The'inspector�must receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System Bryant 315JAV036070(1) includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 1.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 1.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 1.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 1.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. _ r EnergyPro 5.1 bv EnerqySoft User Number: 8165 RunCode: 2013-01-02T15:54:43 ID: 62649 Page 3 of 7 Reg: 212-N00704171B-000000000-0000 ,Registration Date/Time: 2012/12/13,,18:31:00 HERS Provider: CalCERTS, Inc r Blect_oni.cally Filed by Gangyi Zhou. and Authenticated at Ca10ERTS.com - 1J3/2013 Electronically Signed at Ca10ERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 Of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date CORAL MOUNTAIN - PLAN C ❑ Multi Family ❑ Existing+ Addition!Alteration 11312013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV I<Btu/fta- r North East South west Space Heating 5.87 4.07 1.81 4.30 1.57 4.07 1.80 3.91 1.96 Space Cooling 71.49 41.14 30.35 40.47 31.02 40.32 31.17 41.44 30.05 Fans 14.33 14.87 -0.54 14.65 -0.32 14.61 -0.28 14.97 -0.64 Domestic Hot Water 12.80 9.12 3.69 9.12 3.69 9.12 3.69 9.12 3.69 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 104.50 69.20 35.30 68.54 35.96 68.12 36.38 69.44 35.06 Percent Better Than Standard: 33.8 % 34.4 % 34.8 % 33.6 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four Orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (M 791 101 Fuel Available at Site: Natural Gas (N) 919 0 Raised Floor Area: 0 (E) 1,104 147 Slab on Grade Area: 0 (S) 1,170 182 Average Ceiling Height: 11.2 Roof 2,849 0 Fenestration Average U-Factor: 0•29 TOTAL: 429 Average SHGC: 0.31 Fenestration/CFA Ratio: 15.1 REMARKS 77, STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GMEP Engineers Address 4400 Campus Drive Name Gangyi Zhou 1/3/2013 CitylStatelZip Newport Beach, CA 92660 Phone 9497521612 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge; insulation installation quality., and building envelope sealing require installer testing and certification and field verification by an approved HERS rater, Designer or Owner (per Business & Professions Code) Company POON DESIGN INC Address 315 S. Beverly Drive, Suite 206 Name C25529 1 /7/13 City/State/Zip Beverly Hills, CA 90212 Phone 310-277-8855 Signed License # Date EnerqyPro 5.1 by Ener Soft User Number: 8165 RunCode: 2013.01-02T15:54:43 ID: 62649 Page 4 of 7 Reg: 21,2-1007041 7B-000000000-000o Registration Date/Tine- 201.2/12/13 18:31:00 HERS Provider: Ca.10ERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Signed at CalCERTS.com by„Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name MOUNTAIN - PLAN C Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration/2013 7DateCORAL OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azrn Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Wall 663 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 497 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Wall 70 0.057 R-19 4.0 None 270 90 New 4.3.1-A5 Conditioned Area Wall 79 0.057 R-19 4.0 None 90 90 New, 4.3.1-A5 Conditioned Area Roof 1,041 0.028 R-38 0 0 New 4.2.2-A 19 Conditioned Area Wall 256 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 595 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 248 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Wall 294 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Roof 1,250 0.028 R-38 0 0 New 4.2.2-A19 Conditioned Area Wall 283 0.069 R-21 90 90 New " 4.3.1-A6 Conditioned Area Wall 243 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Wall 326 0.069 R-21 270 - 90 New 4.3.1-A6 Conditioned Area Roof 558 0.028 R-38 0 0 New 4.2.2-A19 Conditioned Area FENESTRATION SURFACE DETAILS ID Type Area U-Factor. SHGC Azm Status Glazing Type Location/Comments 1 Window 8.2 0.290 NFRC 0.33 NFRC 180 New Andersen Double Pane Low E(1 Conditioned Area 2 Window 8.2 0.290 NFRC 0.33 NFRC 180 New Andersen Double Pane Low E(1 Conditioned Area 3 Window 8.2 0.290 NFRC 0.33 NFRC 180 New Andersen Double Pane Low E(1 Conditioned Area 4 Window 28.2 0.290 NFRC 0.29 NFRC 180 New Plastpro Low E Conditioned Area 5 Window - 28.2 0.290 NFRC 0.29 NFRC, .: 180 New_,.,,,_.,,._ Plastpro Low E. Conditioned Area 6 Window 1,. 28.2 0.290 NFRC a 0.29 NFRC -180 New . '+, Plastpro Low E 1J. ; ,e- ? Conditioned Area 7 Window '28.2 0.290 NFRC i 0.29 NFRC 180 New Plastpro Low E v . r, Conditioned Area 8 Window 28.2 1 0.290 NFRC 0.29 NFRC `° ' ,­4180 New.zi: - Plastpro Low E q Conditioned Area 9 Window 82 10,290 NFRC 0.33 NFRC" 270 New, _' : Andersen Double Pane Low E(1 Conditioned Area;, 10 Window , i 8.2 ;, 0.290. NFRC 0.33 NFRC ' 270 New' ° Andersen. Double Pane Low E(1 Conditioned Area 11 Window 8.2 ..: 0.290 NFRC; ---^0.33 NFRC.. ^-.- 270 New Andersen Double Pane Low E(1 Conditioned Area 11- 12 Window 8.2 0.290 NFRC 0.33 NFRC 90 New Andersen Double Pane Low E(1 Conditioned Area 13 Window 8.2 0,290 NFRC 0.33 NFRC 90 New Andersen Double Pane Low E(1 Conditioned Area 14 Window 8.0 0.290 NFRC 0.33 NFRC 90 New Andersen Double Pane Low E(1 Conditioned Area 15 Window 22.0 0.320 NFRC 0.28 NFRC 90 New Andersen Double Pane Low E( Conditioned Area 16 Window 22.0 0.290 NFRC 0.33 NFRC 90 New Andersen Double Pane Low E(11 Conditioned Area (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hanq Left Fin Ri ht Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 1 Roll -down Blind or Slats 0.13 2 Roll -down Blind or Slats 0.13 3 Roll -down Blind or Slats 0.13 4 . Roll -down Blind or Slats 0.13 5 Roll -down Blind or Slats 0.13 6 Roll -down Blind or Slats 0.13 7 Roll -down Blind or Slats 0.13 8 Roll -down Blind or Slats 0.13 9 Roll -down Blind or Slats 0.13 10 Roll -down Blind or Slats 0.13 11 Roll -down Blind or Slats 0.13 12 Roll -down Blind or Slats 0.13 13 Roll -down Blind or Slats 0.13 14 Roll -down Blind or Slats 0.13 15 Roll -down Blind or Slats 0.13 16 Roll -down Blind or Slats 0.13 EnerqyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-02Ti5:54:43 ID: 62649 Page 5 of 7 Reg: 212-N0070417B-000000000-0000 Registration Date/Time: 2012/12/13.18:31:00 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi thou and Authenticated at CalCERTS.com 1/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1R Project Name CORAL MOUNTAIN - PLAN C Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt 'Status' Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame ' Y FENESTRATION SURFACE DETAILS ID Type -Area U-Factor SHGC Azm Status Glazin -T e' Location/Comments 17 Window 28.2 0.290 NFRC 0.29 1 NFRC 90 New Plastpro Low E Conditioned Area 18 Window 8.0 0.290 NFRC 0.33 NFRC 180 New Andersen Double Pane Low E(1 Conditioned Area 19 Window 20.0 0.290 NFRC 0.33 NFRC ' 270 New Andersen Double Pane Low E(1 Conditioned Area 20 Window 20.0 0.290 NFRC 0.33 NFRC 270 New Andersen Double Pane Low E(1 Conditioned Area 21 Window, . 28.2 0.290 NFRC . 0.29 NFRC .270 New, „_ , Plastpro Low E.,. _ _ _:,, Conditioned Area 22 Window ` , 22.0 0.290 NFRC 0.33 NFRC =90 New . t,_ Andersen Double Pane Low E(1 Conditioned Area 23 Window `28.2 0.290 NFRC 0.29 NFRC :. 90 New; .,_ .; Plastpro Low Ev, Conditioned Area 24 Window 8.0 <'0.290 NFRC,-. 0.33 NFRC . ;_4 180 New, ,, v Andersen'Double Pane Low E(1 Conditioned Area 25 Window - 8.0 J 0.290 NFRC 0.33 NFRC 4' 270 New r. Andersen Double Pane Low'E(i Conditioned Area, <7; (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin. Right Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 17 Roll -down Blind or Slats 0.13 18 Roll -down Blind or Slats 0.13 19. Roll -down Blind or Slats 0.13 20 Roll -down Blind or Slats 0.13 21 Roll -down Blind or Slats 0.13 - 22 Roll -down Blind or Slats 0.13 23 Roll -down Blind or Slats 0.13 24 Roll -down Blind or Slats - 0.13 25 Roll -down Blind or Slats 0.13 EneigyPro 5.1 by EnergySoft User Number. 8165 RunCode: 2013-01-02T15:54:43 ID: 62649 Page 6 of 7 Reg: 212-N0070417B-000000000-0000 Registration Date/Time: 2012/12/13 18:31:00 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at'Ca10ERTS.com'-,1/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN C Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 BUILDING ZONE INFORMATION System Name • Zone Name' Floor Area ft Volume Year Built New Existing Altered Removed 3.5T Carrier COMMON AREA 1,041 15,615 2.5T Carrier EAST WING 1,250 11,250 1.5T. Carrier WEST WING 558 5,022 Totals Z849 0 0 0 HVAC SYSTEMS System Name Qty. Heating Ty e Min. Eff. Cooling Type Min. Eff. Thermostat Type Status 3.5T Carrier 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 2.5T Carrier 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 1.5T Carrier ,,, 1 ., Central Furnace 80% AFUE SplitAir. Conditioner_ 16.0 SEER Setback New r ,. HVAC DISTRIBUTION 'a # .. I!' `<" Jf A r i ir V, ei System Name Heating :Cooling -� Duct Location Ductti R-Value Ductsv" Tested? Status 3.5T Carrier Ducted Ducted Conditioned 6.0 m New 2.5T Carrier Ducted Ducted Conditioned 6.0 m New 1.5T Carrier Ducted Ducted Conditioned 6.0 El New WATER HEATING SYSTEMS S stem Name Qty. Type, • Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status RTG-95DVN 1 Instant Gas Kitchen Pipe Ins 199,900 0 0.84 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control - Hot Water Piping Length ft 0 O 76 a a C System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried „ ❑ EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-02T15:54:43 ID: 62649 Page 7 of 7 Reg: 212-N0070417B-000000000-0000 Registration Date/Time: 2012/12/13 18:31:00 HERS Provider: CalCERTS, Inc MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name CORAL MOUNTAIN - PLAN C Date 1 11212013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-1 11 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. ' 150 (a): Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. ` 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. ` 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoR User Number: 8165 RunCode: 2013-01-02T15:54:43 ID: 62649 Page 10 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN C 11212013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CIVIC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d), §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoR User Number: 8165 RunCode: 2013-01-02T15:54:43 ID: 62649 Page 11 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN C 11212013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be hi h efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130 d . §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoR User Number: 8165 Run Code: 2013-01-02T15:54:43 ID: 62649 Page 12 of 16 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN C 1/2/2013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard ProDosed Mar in Margin Standard % Better' Space Heating 5.87 4.07 1.81 1 35.30 / 104.50 = 33.8 % Space Cooling 71.49 41.14 30.35 Cooling Standard Heat Rejection 0.00 0.00 0.00 30.35 / 71.49 Indoor Fans 14.33 14.87 -0.54 Incentive Eligibility Yes No Domestic Hot Water 12.80 9.12 3.69 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ ❑ Conditioned Floor Area = 2,849.0 Rz TOTALS: 104.50 69.20 35.30 Number of Bedrooms = 3 Energy Star V3 Target = 20 % ANNUAL SITE ENERGY USE 5pm Standard Pro osed Mar in 7Demand Facing North kW 9.1 6.11 1 3.1 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 104.60 0.00 72.52 0.00 32.08 Space Cooling 9,147.56 0.00 5,136.65 0.00 4,010.91 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 2.007.66 0.00 2,013.24 0.00 -5.57 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 11,155.22 349.94 r 7,149.89 246.85 4,005.33 103.08 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available only through the California from step 2) Electricity (kWh) 33.8 % Rate from Ste 3 Subtotal 0.97 xi 4,005.33 Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program Natural Gas 33.8 % �� $/� kW 3.86 x 103.08 requirements to qualify. $398 Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific Gas and Energy Star Incentive n/a x 10% r Electric Company Green Home Incentive nia x 10% SOUIHER+N CALWORNIA kF I E D I S O N° Compact Home Incentive nia x 15% n/a Are EMSON Compam Photovoltaic Incentive nia x SDGE DC Rating kW f A SemtYra Energy wUrav" JrAff� NSHP n/a ��t califvteir n a Total = $4so7 G., h0y'� M n *Sen,pr, larergyurm advanced *% Better than in this equation is limited to 45 EnergyPro5.1.7.7 by EnergySoR User Number: 8165 Run Code: 2013-01-02T15:54:43 ID: 62649 Page 13 of 16 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN C 11212013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard % Better' Space Heating 5.87 4.30 1.57 1 35.96 / 104.50 = 1 34.4 % Space Cooling 71.49 40.47 31.02 Cooling Standard Heat Rejection 0.00 0.00 0.00 31.02 / 71.49 = 43.4 Indoor Fans 14.33 14.65 -0.32 Incentive Eligibility Yes No Domestic Hot Water 12.80 9.12 3.s9 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ ❑ Conditioned Floor Area = 2,849.0 R2 TOTALS: 104.50 68.54 35.96 Number of Bedrooms = 3 Energy Star V3 Target = 20 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing East Peak Demand kW 9.11 1 5.93.2 EStandard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh (therms) kWh (therms) Space Heating 0.00 104.60 0.00 76.69 0.00 27.91 Space Cooling 9,147.56 0.00 5,044.16 0.00 4,103.40 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 2,007.66 0.00 1,984.30 0.00 23.37 0.00 Domestic Hot Water 0.00 245.33 0.00 1 174.331 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 11,155.22 349.94 7,028.45 251.02 4,126.77 98.92 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) Rate from Ste 3 x 1 4,126.77 Subtotal Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program Natural Gas 34.4 % �� $/� kW X requirements to qualify. 3.93 98.92 $389 Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific Gas and Energy Star Incentive n/a x 10% Electric Company Green Home Incentive nia x 10% SOUTHERN CALIFORNIA its• E D' J O N' Compact Home Incentive n/a x 15% ;\n EUlyfL`.'!X!'i:Rh17t{1\Sil' Canspar.; Photovoltaic Incentive n/a x sf DC Rating kW 9 A Wsempra Energy Utility' } , NSHP n/a w ca i Orn a "-' TOtal mmnam advanced Orne"s- A *Senlpm [nergyuouay- "% Better than in this equation is limited to 45% EnergyPro5.1.7.7 by EnergySoR User Number: 8165 RunCode: 2013-01-02T15:54:43 ID: 62649 Page 14 of 16 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN C 11212013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Margin Margin Standard % Better* Space Heating 5.87 4.07 1.80 36.38 / 104.50 = 1 34.8 % Space Cooling 71.49 40.32 31.17 Coolin Standard Heat Rejection 0.00 0.00 0.00 31.17 / 71.49 = 1 43.6 Indoor Fans 14.33 14.61 -0.28 Incentive Eligibility Yes No Domestic Hot Water 12.80 9.12 3.69 Owner Incentive (>=15%) [a ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) m ❑ Conditioned Floor Area = 2,849.0 ft2 TOTALS: 104.50 68.12 36.38 Number of Bedrooms = 3 Energy Star V3 Target = 20 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard M Facing South Peak Demand kW 9.1 7n7 EStandard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms (kWh) therms kWh therms Space Heating 0.00 104.60 0.00 72.56 0.00 32.04 Space Cooling 9,147.56 0.00 5,104.25 0.00 4,043.31 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 2,007.66 0.00 2,003.91 0.00 3.75 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 D.00 0.00 0.00 TOTALS:' 11,155.22 349.94 7,108.16 246.90 4,047,06 103.04 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24` Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) Rate from Ste 3 x 4,047.06 Subtotal Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program requirements to qualify. Natural Gas 34.8 % �� $/kW kW 3.98 X f03.04 $410 Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific Gas and Energy Star Incentive n/a x 10% Electric Company Green Home Incentive n/a x 10% A S0U1HFRN CALIFORNIA E D I S O N Compact Home Incentive n/a x 15% An EDISON:1.1Tf."Rl;�Y7t3\al' Ccmp:v, Photovoltaic Incentive nia x SD E DC Rating kW A (IySempra Energy u,irry" NSHP MQ,. jj� califd it a '- Total = $s,oas P.m advanced Ones n WSempra laiergyurny- *% Better than in this equation is limited to 45 % EnergyPro 5.1.7.7 by EnergySoff User Number: 8165 RunCode: 2013-01-02T15:54:43 ID: 62649 Page 15 o6 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN C 11212013 ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Mar In Standard % Better' Space Heating 5.87 3.91 1.96 35.06 / 104.50 = 33.6 Space Cooling 71.49 41.44 30.05 Cooling Standard Heat Rejection 0.00 0.00 0.00 30.05 / 71.49 = 42.0 Indoor Fans 14.33 14.97 -0.64 Incentive Eligibility Yes No Domestic Hot Water 12.80 9.12 3.69 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) m ❑ Conditioned Floor Area = 2,849.0 ft2 TOTALS: 104.50 69.44 35.06 Number of Bedrooms = 3 Energy Star V3 Target = 20 ANNUAL SITE ENERGY USE 5pm Standard Proposed Mar in Av7Demand Facing West PekW s.1 5.9 3.2 EStandard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms (kWh) therms (kWh) therms Space Heating 0.00 104.60 0.00 69.78 0.00 34.83 Space Cooling 9,147.56 0.00 5,260.84 0.00 3,886.72 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 2,007.66 0.00 2,054.25 0.00 -46.59 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 11,155.22 349.94 7,315.10 244.11 3,840.13 iii 105.83 • , POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) 33.6 % �' Rate from Ste 3 Subtotal 0.9s x 3,840.13 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 33.6 % �' 168 x NOT GUARANTEED. Projects must meet all other program Natural Gas 33.6 % kW kW $/� X 105.83 requirements to qualify. 3.84 _ $406 Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific Gas and Energy Star Incentive n/a x 10% Electric Company Green Home Incentive n/a x 10% SOU1HO \ CALIFORNIA y EDiSON' Compact Home Incentive n/a x 15% All EDISU.\' l.t7T 6\.fTlt1\':Vl' Cump°n, Photovoltaic Incentive n/a x ,AV G sL DC Rating kW A St: mllra Emery inlay' NSHP .f ti . caiifdrn a �'� � Total $a,s31 =0 advanced h ornes- n *Sempra Energymeay" *% Better than in this equation is limited to 45% EnergyPro 5.1.7. 7 by EnergySoff User Number: 8165 Run Code: 2013-01-02T15:54:43 ID: 62649 Page 16 of 16 BUILDING ENERGY ANALYSIS REPORT PROJECT: CORAL MOUNTAIN = PLAN D LA QUINTA, CA Project Designer: POON DESIGN INC 315 S. Beverly Drive, Suite 206 Beverly Hills, CA 90212 310-277-8855 Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521612 �OQFtOFESslo �p\1GY1 Job Number: c; 62649 *, Ex� 427 M Date: CALIFO 1 /3/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Ener Pro 5:1 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:33:34 ID: 62649 TABLE OF CONTENTS Cover Page Table of Contents Form CF-1 R Certificate of Compliance Form MF-1 R Mandatory Measures Summary Form UTIL-1 R Utility Incentive Worksheet EnergyPro 5.1 by EnergySoft Joti Number: ID: 62649 User Number: 8165 1 2 3 9 12 Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name CORAL MOUNTAIN - PLAN D Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,81 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ff) Features see Part 2 of 5 Status Wall - Wood Framed R-21 ' ' 2,121 New Roof Wood Framed Rafter R-38 2,814 New FENESTRATION U- Exterior Orientation Area(fi<) Factor SHGC Overhang Sidefins Shades Status Front (N) 44.0 0.300 0.29' none none Roll -down Blind or Slats New Left (E) ,.G ..+�,�70.5 0.2901�;-*-c , 0.29—none,;, .,none �r-. ,_ ug Screenp+a.:,., New Right (K9 18.0 0.290 j 0.33 none ," none, w'Roll-down Blind or Slats New Right (tM 0.290 0.29 none ' _ .Bug Screen * T _ New --none Front ,142.3 I, 0.290 0 29 -_ `. none ..'one g � ; # 8u Screen :+,s New Left (E) •- , i 22.6:; 0.800 .�? 0 29, ..none P none,., r Roll down Blind or; Slats , ' r ;:New Rear (S) 66.0 0.320 0.28 none none Roll -down Blind or Slats New HVAC SYSTEMS Ot . Heating Min. Eff Cooling. - Min. Eff - Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status 3.5T Carrier Ducted Ducted Conditioned 6.0 New 3.5T Carrier Ducted Ducted Conditioned 6.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Instant Gas 0 0.84 Kitchen Pipe Ins New EnergyPro 5.1 by Energ Soft User Number: 8165 RunCode: 2013-01-03T17:33:34 ID: 62649 Page 1 of 6 Reg: 212-N0070418D-000000000-0000 Registration-Date/Time: 2012/112/13 18:31:34 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN D Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System Bryant 315JAV048090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Bryant 315JAV048090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnerqyPro 5.1 by EnerpySoft User Number: 8165 RunCode: 2013-01-03T17:33:34 iD: 62649 Pa e 2 of 6 Reg: 212-N0070418D-000000000-0000 Registration Date/Time: 2012/12/13 18:31:34 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou. and Authenticated at CaICE'RTS.com - 1/3/2013 Electronically Signed at Ca3CERTS.com by Russell Jones (Alta Verde Builders) 1/3/201.3 PERFORMANCE CERTIFICATE: Residential (Past 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date CORAL MOUNTAIN - PLAN D ❑ Multi Family ❑ Existing+ Addition/Alteration 11312013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV kgtu/ft2- r North East South west Space Heating 3.44 2,09 1,36 1.89 1.56 2.00 1.44 2.19 1.26 Space Cooling 57.58 35.89 21.69 36.34 21.24 36.56 21.02 35.64 21.94 Fans 11.53 13.11 -1.58 13.25 -1,72 13.32 -1,79 13.02 -1.49 Domestic Hot Water 12.96 9.23 3.73 9.23 3.73 9.23 3.73 9.23 3.73 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 85.51 60.31 25.20 60.70 24.81 61.11 24.40 60.07 25.44 Percent Better Than Standard: 29.5 % 29.0 % 28.5 % 29.7 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 759 86 Fuel Available at Site: Natural Gas (E) 682 93 Raised Floor Area: 0 (S) 611 66 Slab on Grade Area: 0 (M 367 53 Average Ceiling Height: 11.1 Roof 2,814 0 Fenestration Average U-Factor: 0.30 TOTAL: 298 Average SHGC: 0.29 Fenestration/CFA Ratio: 10.6 °i REMARKS }. ' f r. STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GMEP Engineers 11312013 Address 4400 Campus Drive Name Gangyi Zhou City/State,Zip Newport Beach, CA 92660 Phone 9497521612 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge; insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company POON DESIGN INC Address 315 S. Beverly Drive, Suite 206 Name C25529 117/13 City/StatetZip Beverly Hills, CA 90212 Phone 310-277-8855 Signed License # Date Ener Pro 5.1 by EnerqySoft User Number: 8165 RunCode: 2013.01-03T17:33:34 ID: 62649 Page 3 of 6 Reg: 212-NO070418D-000000000-0000 Registration DatefTime: 201.2/1.2/13 13:31:34 HERS Provider: Ca10ERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN D Building Type m Single Family ❑Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date I/3/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments CavitylExterior Frame Interior Frame Wall 328 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 245 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 313 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Roof 1,512 0.029 R-38 0 0 New 4.2.2-A18 Conditioned Area Wall 345 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 345 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 545 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Roof 1,302 0.029 R-38 0 0 New 4.2.2-A18 Conditioned Area FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status GlazingType Location/Comments 1 Window 22.0 0.300 NFRC 0.29 NFRC 0 New Andersen Double Pane Low E(1 Conditioned Area 2 Window 22.0 0.300 NFRC 0.29 NFRC 0 New Andersen Double Pane Low E(1 Conditioned Area 3 Window 14.1 0.290 NFRC 0.29 NFRC 90 New Plast ro Low E Conditioned Area 4 Window 14.1 0.290 NFRC 0.29 NFRC 90 New Plastpro Low E Conditioned Area 5 Window 14.1 0.290 NFRC 0.29 NFRC 90 New Plastpro Low E Conditioned Area 6 Window 6.0 0.290 NFRC . 0.33 NFRC 270 New Andersen Double Pane Low E(2 Conditioned Area 7 Window 6.0 0.290 NFRC 0.33 NFRC 270 New Andersen Double Pane Low E( Conditioned Area 8 Window 6.0 0.290 NFRC 0.33 NFRC 270 New Andersen Double Pane Low E(2 Conditioned Area 9 Window 14:1 0.290 NFRC 0.29 NFRC 270 New Plastpro Low E Conditioned Area 10 Window 7.1 0.290 NFRC 0.29 NFRC 270 New Plastpro Low E Conditioned Area 11 Window 7.1 0.290 NFRC 0.29 NFRC 270 New Plastpro Low E Conditioned Area 12 Window 7.1 0.290 NFRC 0.29 NFRC 270 New Plastpro Low E Conditioned Area 13 Window 28.2 0.290 NFRC 0.29 NFRC 0 New Plastpro Low E Conditioned Area 14 Window 14.1 0.290 NFRC 0.29 NFRC 0 New Plastpro Low E Conditioned Area 15 Window 22.0 0.300 NFRC 0.29 NFRC 90 New Andersen Double Pane Low E(1 Conditioned Area 16 Window 28.2 0.290 NFRC 0.29 NFRC 90 New Plastpro Low E Conditioned Area (1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B - Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hanq Left Fin Ri ht Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 1 Roll -down Blind or Slats 0.13 2 Roll -down Blind or Slats 0.13 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Roll -down Blind or Slats 0.13 7 Roll -down Blind or Slats 0.13 8 Roll -down Blind or Slats 0.13 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Roll -down Blind or Slats 0.13 16 18ug Screen 1 0.76 EnergyPro 5.1 by EnergySoft User Number 8165 RunCode: 2013-01-03T17:33:34 ID: 62649 Pa e 4 of 6 Reg: 212-N0070418D-000000000-0000 Registration Date/Time: 2012/12/13 18:31:34 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders).1/3/2013 CERTIFICATE OF COMPLIANCE: Residential I - (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN D Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame I Interiorl Frame FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC2 Azm Status Glazing Type Location/Comments 17 Window 22.0 0.320 NFRC 0.28 NFRC 180 New Andersen Double Pane Low E( Conditioned Area 18 Window 22.0 0.320 NFRC 0.28 NFRC 180 New Andersen Double Pane Low E( Conditioned Area 19 Window 22.0 0.320 NFRC 0.28 NFRC 180 New Andersen Double Pane Low E( Conditioned Area (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hanq Left Fin Ri ht Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t- 17 Roll -down Blind or Slats 0.13 18 Roll -down Blind or Slats 0.13 19 Roll -down Blind or Slats 0.13 -EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:33:34 ID: 62649 Pa e 5 of 6 Reg: 212-N0070418D-000000000 0000 Registration Date/Time: 2012/1:�/13 18:31:34 HERS Provider: CalCERTS, Inc r Electronically Filed by Gangyi Zhou and Authenticated at Ca10ERTS.com - 1/3/2013 Electronically Siqned at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential_ (Part 5 of 5) CF-1R Project Name MOUNTAIN - PLAN D Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration013 7Date/2CORAL BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft Volume Year Built . New ExistingAltered Removed 3.5T Carrier COMMON AREA 1,512 19,656 3.5T Carrier Bedrooms 1,302 11,718 Totals 1 2,8141 0 0 0 HVAC SYSTEMS System Name Qty. Heating Ty e Min. Eff. Cooling Type Min. Eff. Thermostat Type Status 3.5T Carrier i Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 3.5T Carrier 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New �,.,"`.,^.''�+!sag: "�"' .."f"^��'j„r) . a�j""",�C`:."` '�°".`°i`:�';,"".., f�°''hi'+F�r ;',"•;$+"aq�'?!' �'�, HVAC DISTRIBUTION r F System Name Heating Coolin ` Duct Location Duc . R Value ,. Duct Tested? Status 3.5T Carrier Ducted Ducted Conditioned 6.0 10 New 3.5T Carrier Ducted Ducted Conditioned 6.0 fZJ New WATER HEATING SYSTEMS - S stem Name Qty. Type Distribution Rated, Input Btuh tank. Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status RTG-95DVN 1 Instant Gas Kitchen Pipe Ins 199,900 0 0.84 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft C 0 '6 v Q — r' S stem Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:33:34 ID: 62649 Page 6 of 6 Reg: 212-N0070418D-000000000-0000 Registration Date/Time: 2012/12/13 18:31:34 'HERS Provider: CalCERTS, Inc MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name CORAL MOUNTAIN - PLAN D Date 11312013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of §10411 (a). 117: Exterior doors and windows are weather- stripped; all joints and penetrations are caulked and sealed. 118 a : Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor.. 150 b : Loose fill insulation shall conform with manufacturer's installed desi n labeled R-Value. * 150 c : Minimum R-13 insulation in wood -frame wall or equivalent U-factor.' * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no qreater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is - equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: - §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release. valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. ' 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 8165 Run Code: 2013-01-03T17:33:34 1D: 62649 Page 9 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN D 11312013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CIVIC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heatin . 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ro rammed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pumUmg, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7, §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoR User Number: 8165 Run Code: 2013.01-03Ti7:33:34 ID: 62649 Page 10 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN D 11312013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFIVI at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be hi h efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoff User Number: 8165 RunCode: 2013-01-03T17:33:34 ID: 62649 Page 11 of 15 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN D 11312013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard % Better* Space Heating 3.44 2.09 1.36 25.20 / 85.51 = 29.5 Space Cooling 57.58 35.89 21.69 Cooling Standard Heat Rejection 0.00 0.00 0.00 21.6-9/ 57.58 = 37.7 Indoor Fans 11.53 13.11 -1.58 Incentive Eligibility Yes No Domestic Hot Water 12.96 9.23 3.73 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=309/6) ❑ m Conditioned Floor Area = 2,814.0 ft2 TOTALS: 85.51 60.31 25.20 Number of Bedrooms = 4 Energy Star V3 Target = 15 ENERGY USE 5pm Standard Pro osed Mar in rPeakDe Facing North kW 7.4 1 5.0 1 2.4 ENERGY COMPONENT Standard Proposed Margin Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms (kWh) (therms) (kWh) (therms) Space Heating 0.00 60.69 0.00 36.89 0.00 23.80 Space Cooling 7,121.72 0.00 4,507.13 0.00 2,614.60 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,560.22 0.00 1,761.41 0.00-201.18 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 8,681.95 306.03 6,268.53 211.22 2,413.41 94.81 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) 2s.5 % ��' Rate from Ste 3 0.85 x 2,413.41 Subtotal Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 2s.5 % ��� 148 x NOT GUARANTEED. Projects must meet all other program Natural Gas 2s.5 °i° $/� kW X requirements to qualify. 3.37 94.81 L_ J$32o Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific Gas and Energy Star Incentive n/a x 10% Electric Company Green Home Incentive n/a x 10% sotrrHraM' cAtlraaNtA EDISON' Compact Home Incentive n/a x 15% A,s EDISON 1A'rERAA?70A'a7,d Cwnpary Photovoltaic Incentive n/a x GF� sY DC Rating kW A SempraEnergy.ti'ily' NSHP c li Orn a Totalad--vanced n`Sempra Giergyma�iy` h6mica ' % Better than in this equation is limited to 45 EnergyPro 5.1.7.7 by EnergySoft User Number: 8165 Run Code: 2013-01-03T17.33:34 ID: 62649 Page 12 of 15 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN D 11312013 • • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard % Better' Space Heating 3.44 1.89 1.56 24.81 / 1 85.51 = 29.0 Space Cooling 57.58 36.34 21.24 Cooling Standard Heat Rejection 0.00 0.00 0.00 21.24 / 1 57.58 = 36.9 Indoor Fans 11.53 13.25 -1.72 Incentive Eligibility Yes No Domestic Hot Water 12.96 9.23 3.731 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 2,814.0 ft2 TOTALS: 85.51 60.70 24.81 Number of Bedrooms = 4 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing East Peak Demand kW 7.4 1 5.1 2.3 Standard Proposed Margin E ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms kWh therms (kWh) (therms) Space Heating 0.00 60.69 0.00 33.33 0.00 27.36 Space Cooling 7,121.72 0.00 4,586.59 0.00 2,535.13 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,560.22 0.00 1,785.90 0.00-225.68 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 1 0.00 0.00 0.00 TOTALS: 8,681.95 306.03 6,372.49 207.66 2,309.45 98.36 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available from step 2) Rate from Ste 3 Subtotal only through the California Electricity (kWh) 2s.o °i o.a3 x 2,309.45 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program Natural Gas 2s.o % e' $/kw kw x requirements to qualify. 3.32 98.36 = $327 Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific leas and Energy Star Incentive n/a x 10% Electric Company Green Home Incentive n/a x 10% SOUTHER\ CALIFORNIA ED I S O N° Compact Home Incentive n/a x 15% An EDIS0.\ h\'1',;RA'0'10N.,,Ls Cwnpzmg Photovoltaic Incentive n/a x SDGE DC Rating kW A VSt?ml)ra rnergyutirty"� NSHP ��` call Ora '` � Total [Womnam ��qy� q�p,,p�.ya,py �nwy iAl�a� va �c d O 11 �*) A *Sempri L'nergy meay" '% Better than in this equation is limited to 45 EnergyPro 5.1.7.7 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:33:34 ID: 62649 Page 13 of 15 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN D 1/3/2013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar cfin Margin Standard % Better* Space Heating 3.44 2.00 1.44 24.40 / 85.51 = 28.5 % Space Cooling 57.58 36.56 21.02 Coolin Standard Heat Rejection 0.00 0.00 0.00 21.02 / 57.58 = 36.5 Indoor Fans 11.53 13.32 -1.79 Incentive Eligibility Yes No Domestic Hot Water 12.96 9.23 3.73 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ ❑ Conditioned Floor Area = 2,814.0 ftz TOTALS: 85.51 61.11 24.40 Number of Bedrooms = 4 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing South Peak Demand kW 7.4 1 5.2 1 2.2 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms (kWh) therms kWh therms Space Heating 0.00 60.69 0.00 35.41 0.00 25.28 Space Cooling 7,121.72 0.00 4,552.12 0.00 2,569.60 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1.560.22 0.00 1,774.73 0.00-214.50 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 8,681.95 306.03 6,326.84 209.74 2,355.10 96.29 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available only through the California from step 2) Electricity (kWh) Rate from Ste 3 Subtotal x 2,355.10 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program Natural Gas 28.5 % �� $/� kW x requirements to qualify. 3.26 96.29 $314 Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific Gas and Energy Star Incentive n/a x 10% 1 Electric Company Green Home Incentive nia x 10% SOUTHERN CALIFORNIA ED I S O I * Compact Home Incentive n/a x 15% ;\n Chlju\ k\7I:�..\ 1?7{1.\_tl• CUn:p7r,; Photovoltaic Incentive n/a x SDSf DC Rating kW 9 AWSernpraEnergy uaety NSHP calif6m a *` , Total = $2ss7 r�oaY adlVa Iced i omlems . A ((Sempra I_nerg),°,aly' *% Better than in this equation is limited to 45% EnergyPro5.1.7.7 by EnergySoff User Number: 8165 RunCode: 2013-01-03T17:33:34 0: 62649 Page 14 of 15 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN D 1/3/2013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Margin Margin Standard % Better' Space Heating 3.44 2.19 1.26 1 25.44 / 85.51 = 1 29.7 % Space Cooling 57.58 35.64 21.94 Coolin Standard Heat Rejection 0.00 0.00 0.00 21.94 / 57.58 = 1 38.1 Indoor Fans 11.53 13.02 1.49 Incentive Eligibility Yes No Domestic Hot Water 12.96 9.23 3.73 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 2,814.0 ftz TOTALS: 85.51 60.07 25.44 Number of Bedrooms = 4 Energy Star V3 Target = 15 % ANNUAL SITEENERGY USE e 2pm - 5pm Standard Pro osed Mar in 7Peak Facing West emand kW 7.4 1 5.1 1 2.3 EStandard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms kWh (therms) kWh therms Space Heating 0.00 60.69 0.00 38.64 0.00 22.05 Space Cooling 7,121.72 0.00 4,408.97 0.00 2,712.75 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,560.22 0.00 1,728.02 0.00-167.80 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 8,681.95 306.03 6,137.00 212.98 2,544.95 93.05 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) 2s.7% �� Rate from Ste 3 o.s5 X1 2,544.95 Subtotal Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 2s.7 % 14s x NOT GUARANTEED. Projects must meet all other program Natural Gas 2s.7 % $/� kW x requirements to qualify. 3.4o 93.05 $316 Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific Gas and Energy Star Incentive n/a x 10% Electric Company Green Home Incentive n/a x 10% V SOU'1HYRN CALIFORNIA `> E D I S O N Compact Home Incentive n/a x 15% %11 riD1SON 1,Y1,4R:N 17,10.V10 Omlp n� A Photovoltaic Incentive n/a x rt✓` DC Rating kW A (a�Sennpra E.nerg}r�.rty NSHP M- Wmp, , cafifdrnia Total y advanced ho es- A WSenrpra I:nergl•macy" *% Better than in this equation is limited to 45% EnergyPro5.1. 7. 7 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:33:34 0: 62649 Page 15 of 15 BUILDING ENERGY ANALYSIS REPORT PROJECT: . CORAL MOUNTAIN - PLAN J LA QU INTA, CA Project Designer: ` POON DESIGN INC 315 S. Beverly Drive, Suite 206 Beverly Hills, CA 90212 310-277-8855 h Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521612 �0 pROFESS�O GP�1G Y1 o y� Job Number: M3427 z * EXP M 62649 q N\P Date: r °�.G ►Foa 1 /2/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 5.1 by Energ Soft User Number 8165 RunCode: 2013-01-02Ti6:27:22 ID: 62649 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary 9 Form UTIL-1 R Utility Incentive Worksheet 12 t Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Signed at Ca10ERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name CORAL MOUNTAIN - PLAN J Building,Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,668 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ff) Features (see Part 2 of 5) Status Wall Wood Framed ' R-21 3,093 New Roof Wood Framed Rafter R-38 Z668 New 4 _ f FENESTRATION U- Exterior Orientation Area(fe) Factor SHGC Overhang Sidefins Shades f ' Status Right (N) 44.0 0.300 0.29 none none Roll -down Blind or Slats New Right (N) r*►^ ,n 16.0 0.290,,--.%z---0.33.E none noneRoll-down Blind_or, Slats New Right (N) � 56.4 0.290 . 0.29 ,' .none," ) none I Bug Screen , , , ;� '• New Left (S) ,. i 6.0 .� 0.290 0.33 ,-• none -= none' j , .' Roll-downn Blind or Slats . New Front (E) „ 33.00.290 0.33 " none ` none " Roll down Blind or Slats , `' r- fir j .`New Z. Front (E) ` 84 6' _ 0.290 xe,� ,0 29 £ =none',., .5, g none �T. # Bug. Screen • S F`,r{' ''� ff ' New Rear- (04 28.0 0.280 0.28 none none Roll -down or Slats New -Blind Rear (W) 24.0 0.290 0.33 none none Roll -down Blind or Slats New Front (E) 22.0 0.320 0.28 none none Roll -down Blind or Slats New Left (S) 44.0 0.320 0.28 none none Roll -down Blind or Slats New t HVAC SYSTEMS , Ot . Heating Min. Eff CoolingMin. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling.Duct Location R-Value Status 3.5T Carrier Ducted Ducted Conditioned 6.0 t New 3.5T Carrier Ducted Ducted Conditioned 6.0 ' New i WATER HEATING Qty. Type Gallons Min. Eff Distribution ( Status 1 Instant Gas 0 0.84 Kitchen Pipe Ins New - r t r Energ Pro 5.1 by Energ Soft User Number.- 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 1 of 6 Reg: 212-N0070419C-000000000-0000 Registration Date/Time: 2012/12/13 18:31:56 HERS Provider: Ca10ERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name , CORAL MOUNTAIN - PLAN J Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. HERS REQUIREDNERIFICATION-, y�; � , .."A. Items in this section require field testing and/or verification' by a certified'HERS Rater: The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System Bryant 315JAV048090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Bryant 315JAV048090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. ' The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. `ID: EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:27:22 62649 Page 2 of 6 Reg: 212-N0070419C-000000000-0000 Registration Date/Time: 2012/12/13 18:31:56 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at-CalCERTS.com - 1/3/2013 Electronically Signed at Ca10ERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type , m Single Family ❑ Addition Alone Date CORAL MOUNTAIN - PLAN J ❑ Multi Family ❑ Existing+ Addition/Alteration 11312013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV kBtU/ft2- r North East South West Space Heating 5.28 3.70 1.58 3.48 • 1.80 3.10 217 3.32 1.96 Space Cooling ' 68.45 40.40 26.06 39.82 28.64 41.69 26.76 41.77 26.68 Fans 13.69 14.78 -1.10 14.59 490 •15.22 -1.53 15.24 -1.55 Domestic Hot Water 13.67 9.73 3.94 9.73 3.94- 9.73 3.94 9.73 3.94 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 101.09 68.61 32.48 67.62 33.47 69.74 31.34 70.06 31.02 Percent Better Than Standard: 32.1 % 33.1 % 31.0 % 30.7 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 727 140 Fuel Available at Site: Natural Gas (S) 739 60 Raised Floor Area: o (169 466 52 Slab on Grade Area: 0 (N) 1,529 116 Average Ceiling Height: 11.7 Root 2,668 0 • Fenestration. Average U-Factor: 0.30 TOTAL: 368 Average SHGC: 0.30 Fenestration/CFA Ratio: 13.8 % REMARKS ° ]t^fjrrl ,fit STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts.1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete.' Documentation Author Company GMEP Engineers s6" Address 4400 Campus Drive c Name Gangyi Zhou 71312013 City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone 9497521612 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company POON DESIGN INC F Address 315 S. Beverly Drive, Suite 206 Name C25529 1 /7/13 City/State/Zip Beverly Hills, CA 90212 Phone 310-277-8855 Signed License #t Date EnerqyPro 5.1 by Ener�qySoft User Number. 8165 RunCode: 2013.01-02T16:27:22 ID: 62649 Page 3 of 6 Reg: 212-N0070419C-000000000-0000 Registration Date/Time: 2012/12/13 18:31:56 HERS Provider: CalCERTS, Inc f Electronically Filed by Gangyi Zhou and•Authenticated at.Ca10ERTS.com - 1/3/2013 Electronically Siqned at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential - (Part 4 of 5) CF-1 R Project Name MOUNTAIN - PLAN J Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration/2093 7DaleCORAL OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation - Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Wall 792 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 82 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Wall 245 r0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 414 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area - Roof 1,452 0.028 R-38 0 0 New 4.2.2-A 19 Conditioned Area Wall 621 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 342 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 597 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Roof 1,216 0.028 R-38 0 0 New 4.2.2-A19 t Conditioned Area FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 22.0 0.300 NFRC 0.29 NFRC 0 New Andersen Double Pane Low E(1 Conditioned Area 2 Window 22.0 0.300 NFRC 0.29 NFRC 0 New Andersen Double Pane Low E(1 Conditioned Area 3 Window 8.0 0.290 NFRC 0.33 NFRC 0 New Andersen Double Pane Low E(2 Conditioned Area 4 Window 8.0 0,290 NFRC 0.33 NFRC 0 New Andersen'Double Pane Low E(2 Conditioned Area 5 Window _• . 28.2 0.290 NFRC .0.29 NFRC _a0 New, . PlastproLowE,, _ _ Conditioned Area 6, Window > •'8.0 0.290 NFRC -10.33 NFRC '180 New 1 1 Andersen Double Pane Low E(2 Conditioned Area 7 Window ' 11.0 0.290 NFRC t 0.33 NFRC 90 New..' .. Andersen,Double Pane Low E(2 Conditioned Area 8 . Window 11.0 0.290 NFRC 0.33 NFRC :...>,dl 90 New,,- - Andersen Double Pane Low, E(2 Conditioned Area 9 Window 130 40.290 NFRC- ' 0.33 NFRC V 90 New Andersen Double Pane Low E(2 Conditioned Area , 10 Window ¢f 28.2 ; .0.296 NFRC 0.29 NFRC .490 :New'.1 ` Plastpro Low 5 " Conditioned Area 11 WhdowA'+' .28.2 _ 0.290 NFRC' -0.29 NFRC 4L 90 New � Plastpro Low E n ,��� Conditioned Area'+ 12 Window 28.2 0.290 NFRC 0.29 NFRC 90 New Plastpro Low E Conditioned Area 13 Window 28.0 0.280 NFRC 0.28 NFRC 270 New Andersen Double Pane Low E(4 Conditioned Area 14 Window 8.0 0.290 NFRC 0.33 NFRC 270 New Andersen Double Pane Low E(2 Conditioned Area 15 Window 8.01 0.290 1 NFRC 0.33 NFRC 270 New Andersen Double Pane Low tQ Conditioned Area 16 Window 8.01 0.290 1 NFRC 0.33 NFRC 270 New . Andersen Double Pane Low E(4 Conditioned Area (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type . SHGC Window Ove hanq Left Fin Ri ht Fin H q7F TWd Len H t LExt RExt Dist Len H t Dist Len H t 1 Roll -down Blind or Slats 0.13 2 Roll -down Blind or Slats 0.13 3 Roll -down Blind or Slats 0.13 - 4 Roll -down Blind or Slats 0.13 5 Bug Screen 0.76 6 Roll -down Blind or Slats 0.13 7 Roll -down Blind or Slats 0.13 8 Roll -down Blind or Slats 0.13 9 Roll -down Blind or Slats 0.13 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Roll -down Blind or Slats 0.13 14 Roll -down Blind or Slats , 0.13 15 Roll -down Blind or Slats 0.13 16 Roll -down Blind or Slats 0.13 EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 4 of 6 Reg: 212-N0070419C-000000000-0000 Registration Date/Time: 2012/12/13 18:31:56 HERS Provider: CalCERTS, Inc 0 Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential - (Part 4 of 5) CF-1 R Project Name _ CORAL MOUNTAIN - PLAN J Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 OPAQUE SURFACE DETAILS Surface T e Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavit Eior xter Frame Interior Frame FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 28.2 0.290 NFRC 0.29 NFRC 0 New Plastpro Low E Conditioned Area 18 Window 22.0 0.320 NFRC 0.28 NFRC 90 New Andersen Double Pane Low E( Conditioned Area 19 Window 8.0 0.290 NFRC 0.33 NFRC 180 New Andersen Double Pane Low E(2 Conditioned Area 20 Window 22.0 0.320 NFRC 0.28 NFRC 180 New Andersen Double Pane Low E( Conditioned Area 21 Window ._ q 22.0 0.320 NFRC 0.28 NFRC, _ _ 180 New v Andersen Double Pane Low E( Conditioned Area r _ �- ♦... ,[T .I .L s3 r V'.t . ,n i_,.' .: F ..." Lr 1 ..3 -- i_. �e A } i., ...'art! {i «, a;�;f' � .+Sd=+-n� ' „ia . 'A`-d:I� 4 '..�.�.� }�".,T �,•.�;-p (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Overhan • Left Fin Right Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen .0.76 18 Roll -down Blind or Slats 0.13 19 Roll -down Blind or Slats 0.13 20 Roll -down Blind or Slats 0.13 21 Roll -down Blind or Slats 0.13 EnergyPro 5.1 by EnergySoft User Number: 8165 Run Code: 2013-01-02T16:27:22 ` ID: 62649 Page 5 of 6 u Reg: 212-N0070419C-000000000-0000 Registration Date/Time: 2012/12/13 18:31:56 HERS'Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at Ca10ERTS.com - 1/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN J Building Type 117 Single Family ❑ Addition Alone ❑ Multi Family. ❑ Existing+Addition/Alteration Date 11312013 BUILDING ZONE INFORMATION - System Name Zone Name . Floor Area ft Volume Year Built New Existing Altered Removed 3.5T Carrier COMMON AREA 1,452 20,328 3.5T Carrier Bedrooms 1,216 10,944 Totals 1 2,6681 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status 3.5T Carrier 1 Central Furnace 80% AFUE Split Air Conditioner: 15.5 SEER Setback. New 3.5T Carrier 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New r. - R Pr ,... y.- .... �.. HVAC DISTRIBUTION-- ,�Y`r�DuctA System Name Heating Cooling Duct Location i.Ja R-Value V, Ducts l Tested? I Status 3.5T Carrier Ducted Ducted Conditioned 6.0 IZI New 3.5T Carrier Ducted Ducted Conditioned 6.0 m New WATER HEATING SYSTEMS ' S stem Name - Qty. Type Distribution Rated Input Btuh . Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status RTG-95DVN 1 Instant Gas Kitchen Pipe Ins 199,900 0 0.84 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 o, m �a Q — System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number. 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 6 of 6 Reg: 212-N0070419C-000000000-0000 Registration Date/Time: 2012/12/13 18:31:56 HERS Provider: CalCERTS,'Inc MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name CORAL MOUNTAIN - PLAN J Date 11212013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a ' Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. ' 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. " 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wra • is tested, labeled, and installed according to ASTM E1677-95 2000 when s ecified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is — equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the ' outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certifiedthe Solar Rating and Certification Corporation. .by EnergyPro 5.1 by EnergySoR User Number: 8165 Run Code: 2013-01-02T16:27:22 ID: 62649 Page 9 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN J 1 11212013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heatin . 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ro rammed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 112 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 10 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN J 11212013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 11 of 15 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN J 1/2/2013 -TGJGANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Margin Mar In Standard % Better' Space Heating 5.28 3.70 1.58 32.48 / 101.09 = 32.1 % Space Cooling 68.45 40.40 28.06 Cooling Standard Heat Rejection 0.00 0.00 0.00 28.06 / 68.45 = 41.0 Indoor Fans 13.69 14.78 -1.10 Incentive Eligibility Yes No Domestic Hot Water 13.67 9.73 3.94 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=309/6) m ❑ Conditioned Floor Area = 2,668.0 ft2 TOTALS: 101.09 68.61 32.48 Number of Bedrooms = 4 Energy Star V3 Target = 15 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard M Facing North Peak Demand W 8.2 2 771s EStandard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh (therms) kWh therms kWh therms Space Heating 0.00 88.05 0.00 61.79 0.00 26.26 Space Cooling 8,169.54 0.00 4,732.92 0.00 3,436.62 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1.785.62 0.00 1,866.54 0.00 -80.91 0.00 Domestic Hot Water ETOTALS: 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 9,95517 333.38 6,599.46 236.12 1 3,355.71 97.27 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) 32.1 % Rate from Ste 3 o.s2 x 3,355.71 Subtotal Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program Natural Gas 32.1 Rio �� $!kW kW X requirements to qualify. 3.67 97.27 $357 Potential incentives are $!therm therm subject to program limitations Base Incentive Pacific Gas and Energy Star Incentive n/a x 10% Electric Company Green Home Incentive n/a x 10% SOU1HMN CALIFORNIA ED I S O N* Compact Home Incentive n/a x 15% An EDISON 1, 7FR\Arro.V<,L• Cwmml� Photovoltaic Incentive n/a x G,� SD E DC Rating kW Aa"SempraEnergy utiii'yx S N HP • ` cafiforn a `� ' Total �a> [PmPanY -�■�y�■�q)■ = $3sso A 4Sempri E iergyou y V ■■y1�_ ad 1� un ed homes" ■es" '% Better than in this equation is limited to 45 % EnergyPro 5.1.7.7 by EnergySoR User Number: 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 12 of 15 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN J 11212013 - • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Margin Mar in Standard % Better* Space Heating 5.28 3.48 1.80 133.47 / 101.09 = 33.1 % Space Cooling 68.45 39.82 28.64 Cooling Standard Heat Rejection 0.00 0.00 0.00 28.64 / 68.45 = 41.8 Indoor Fans 13.69 14.59 0.90 Incentive Eligibility Yes No Domestic Hot Water 13.67 9.73 3.94 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ ❑ Conditioned Floor Area = 2,668.0 ft2 TOTALS: 101.09 67.62 33.47 Number of Bedrooms = 4 Energy Star V3 Target = 15 % ANNUAL SITE ENERGY USE 2pm - 5pm Standard Pro osed Mar in 7Peak Facing East emand kW 8.2 5.2 1 3.0 EStandard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) (therms) (kWh) therms (kWh) therms Space Heating 0.00 88.05 0.00 58.12 0.00 29.93 Space Cooling 8,169.54 0.00 4,775.02 0.00 3,394.53 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans, 1,785.62 0.00 1,879.44 0.00 -93.82 0.00 Domestic Hot Water 0.00 245.33 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 TOTALS: 9,955.17 333.38EEa 232.45 3,300.71 100.93 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) 33.1 % �' Rate from Ste 3 0.95 X 3,300.71 Subtotal Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 33.1 % �' 166 x NOT GUARANTEED. Projects must meet all other program Natural Gas 33.1 % $/kW kW X requirements to qualify. 3.78 100.93 $382 Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific Gas and- Energy Star Incentive n/a x 10% Electric Company Green Home Incentive n/a x 10% SOUTHERN Cnt.IF0t2'\In ED I S O N' Compact Home Incentive n/a x 15% v+ EDISQN IA'Tl: R t 4TI p,1°. t!! Company 0 Photovoltaic Incentive n/a x sE DC Rating kW A 9-�Sempra Energy uthity` t NSHP cafifdrnia Total Q. d'ranced homes n (�$empra fnergyma�ty" '%, Better than in this equation is limited to 45%, EnergyPro5.1. 7. 7 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 13 of 15 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN J 1/2/2013 •I ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard % Better* Space Heating 5.28 3.10 2.17 31.34 / 1 31.0 Space Cooling 68.45 41.69 26.76 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 26.76 / 1 68.45 Indoor Fans 13.69 15.22 -1.53 Incentive Eligibility Yes No Domestic Hot Water 13.67 9.73 3.94 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ ❑ Conditioned Floor Area = 2,668.0 R2 TOTALS: 101.09 69.74 31.34 Number of Bedrooms = 4 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing South Peak Demand kW 8.2 1 5.4 1 2.8 ENERGY COMPONENT Standard Proposed Margin Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) (therms) (kWh) (therms) kWh (therms) Space Heating 0.00 88.05 0.00 51.82 0.00 36.23 Space Cooling 8,169.54 0.00 5,081.75 0.00 3,087.79 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,785.62 0.00 1,981.88 0.00-196.25 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 9,955.17 333.38 7,063.63 226.15 2,891.54 107.23 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24• Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) 31.0 % Rate from Ste 3 o.ss X1 2,891.54 Subtotal Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program requirements to qualify. Natural Gas 31.0 �i. �� $/kW kW 3.54 X f07.23 $380 Potential incentives are $/therm therm subject to program limitations Base Incentive Gas and Energy Star Incentive nia x 10% InPacific Electric Company Green Home Incentive n/a x 10% soultlrazNI catarolr�lA ED I S O N' Compact Home Incentive n/a x 15% All MISS r.Vrr_F\Arro.\Ar.• Cainpan� � Photovoltaic Incentive n/a x SDGf ,� DC Rating kW A*Sernprar.nergywirty" V �\ NSHP calf drn a .� � Total WmaonY advancedhomes,. o es, A *Sempra fnergymany- *% Better than in this equation is limited to 45 % EnergyPro5.1.7.7 by EnergySoff User Number: 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 14 of 15 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN J 11212013 • • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Mar in Standard % Better' Space Heating 5.28 3.32 1.96 31.02 / 101.09 = 30.7 % Space Cooling 68.45 41.77 26.68 Coolin Standard Heat Rejection 0.00 0.00 0.00 26.68 / 68.45 = 39.0 Indoor Fans 13.69 15.24 -1.55 Incentive Eligibility Yes No Domestic Hot Water 13.67 9.73 3.94 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ ❑ Conditioned Floor Area = 2,668.0 ft2 TOTALS: 101.09 70.06 31.02 Number of Bedrooms = 4 Energy Star V3 Target = 15 % ANNUAL SITE ENERGY USE Ave5pm Standard Pro osed Mar in 7Demand Facing West PekW 8.2 5.7 2.5 ENERGY COMPONENT Standard Proposed Margin Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms (kWh) therms (kWh) (therms) Space Heating 0.00 88.05 0.00 55.39 0.00 32.66 Space Cooling 8,169.54 0.00 4,967.03 0.00 3,202.51 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,785.62 0.00 1,943.55 0.00-157.93 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00E61910.58 0.00 0.00 0.00 TOTALS: 9,955.17 333.38 229.72 3,044.59 103.66 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) Rate from Ste 3 Subtotal x 3,044.59 Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program Natural Gas $/kw kw x l03.66 = $364 requirements to qualify. Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific Gas and Energy Star Incentive n/a x 10% d Electric Company Green Home Incentive n/a x 10% SottlHi R\CALIroRNIA ED I S O N' Compact Home Incentive n/a x 15% All EE.71SC�.i'!k'I'F£R.1'p7"tt):Gsl,• Company Photovoltaic Incentive n/a x GAV SD E A&lfmaSt?mprafnergy.cirty' DC Rating kW NSHP �Q califdp n n Y "^ p Total advanced Os A (�,sempra Iaiergymany- '% Better than in this equation is limited to 45% EnergyPro5.1.7. 7 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 15 of 15 BUILDING ENERGY ANALYSIS REPORT w PROJECT: CORAL MOUNTAIN - PLAN Z LA QUINTA, CA Project Designer: • POON DESIGN INC 315 S. Beverly Drive, Suite 206 Beverly Hills, CA 90212 310-277-8855 Report Prepared by: Gangyi Zhou , GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521,612 0 pR0FESSZ0 GP<,1G YI e GAF O Zc Job Number: • M34279 m EXP 3 62649 s �F �,qr� A IFoaN\P Date: 1 /2/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 5.1 by Energ Soft User Number: 8165 RunCode: 2013-01-02T16:34:03 ID: 62649 • TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary -8 Form UTIL-1 R Utility Incentive Worksheet 11 4 f EnergyPro 5.1 by EnergySofl Job Number: ID: 62649 User Number: 8165 Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Siqned at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name CORAL MOUNTAIN - PLAN Z Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,708 Addition n/a of Stories r 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -= If Yes, A CF-4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special . ' Construction Type Cavity (ft) Features (see Part 2 of 5) Status Wall Wood Framed R-21 1,800 New Roof Wood Framed Rafter R-38 2,708 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang, Sidefins Shades Status Rear (Ko 33.9 0.290 0.33 none none Roll -down Blind or Slats New Front(E) _,. 357.2 0.560 r .::,0.32 .-none q t�,none ;_.ems-Bug,Screen ..., New Front (E),''r '. 35.3 0.380- ' 0.34 :none '"d"'none `-'Roll-down Blind or Slats New Front (E) 28.2 r 0.290 0 29 `= none "�one Bug Screen ,:k_ New n Left (S) f i 44.0 0.290 D 33' 'none; none r f r . _ 11 Roll -down Blind or Slats ' r N6w Right (N) _e. ` f,44.0: ` , �0.310.`�• .� 0.31 t nonee •„ "none1' ,; .;;; Roll -down, Blind or Slats%"a ,New Rear (lAq 26.6 0.280 0.28 none R none Roll -down Blind or Slats New Left (S) 44.0 0.310 0.31 ' none none Roll -down Blind or Slats New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80 % AFUE Split Air Conditioner 15.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status 3.5T Carrier Ducted Ducted Conditioned 6.0 New 3.5T Carrier Ducted Ducted Conditioned 6.0 New WATER HEATING Qt - Type Gallons Min. Eff Distribution Status 1 Instant Gas 0 0.84 Kitchen Pipe Ins New Energ Pro 5.1 by EnerqySoft ' User Number: 8165 RunCode: 2013-01-02T16:34:03 ID: 62649 Page 1 of 5 Reg: 212-N007042OB-000000000-0000 Registration Date/Time: 2012/12/13 18:32:19 HERS Provider: CalCERTS, Inc - r Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN Z Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/3/2013 SPECIAL FEATURES INSPECTION CHECKLIST - The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach.'The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. f „,/�f'_._en.=y� y,,,-.+r �i .py�...r.r�.it� ,K .w�� �..• 'A y`rn HERS REQUIRED.VERIFICATION .M .. �,,•��. ,.,.r, ,r e ." • 4 = � / ,aJp'''«i �. � q. � 47�:�• +�l,. Items in this`section require field testing and%or verificatiorVby a certified' HERS Rater. The inspector must receive a com leted CF-4R form for each of the measures listed below for final to be gi46. The Cooling System Bryant 315JA V048090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. i The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. r The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Bryant 315JAV048090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. r Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. '. The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. I - The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ene Pro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:34:03 ID: 62649 Page 2 of 5 Reg: 212-NO070420B-000000000-0000 Registration Date/Time: 2012/12/13 18:32:19 HERS Provider: CalCERTS, Inc k Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Signed at CaICERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family 0 Addition Alone Date CORAL MOUNTAIN - PLAN 2 ❑ Multi Family 13 Existing+ Addition/Alteration 11312013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV kBtu/ft2 r North East South West Space Heating 4.32 4.75 -0.43 3.74 0.57 4.14 0.18 4.56 -0.26 Space Cooling 70.16 41.77 26.41 47.47 22.71 49.20 20.98 49.51 20.67 Fans 13.96 15.33 -1.38 17.31 -3.36 17.95 4.00 17.93 -3.97 Domestic Hot Water 13.47 9.59 3.88 9.59 3.88 9.59 3.88 9.59 3.88 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 101.93 71.45 30.48 78.12 23.81 80.88 21.04 81.60 20.32 Percent Better Than Standard: 29.9 % 23.4 % 20.6 % 19.9 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration BuildingFront Orientation: All Four orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 i (E) 713 ' 421 Fuel Available at Site: Natural Ga''s (S) .808 88 Raised Floor Area: 0 (149 387 61 Slab on Grade Area: 0 (N) 506 44 Average Ceiling Height: 11.1 Roof 2,708 0 Fenestration Average U-Factor: 0.45 TOTAL: 613 Average SHGC: 0.32 •Fenestration/CFA Ratio: 2P:6 % REMARKS -'ij STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GMEP Engineers 11312013 Address 4400 Campus Drive Name Gangyi Zhou • city/slate/Zipcity/slate/Zip Newport Beach, CA 92660 - Phone 9497521612 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company POON DESIGN INC Address 315 S. Beverly Drive, Suite 206 Name, C25529 1 /7/13 City/Slate/Zip Beverly Hips, CA 90212 Phone 310-277-8855 Signed License fl Date EnerqyPro 5.1 by Ener�qySoft User Number: 8165 RunCode: 2013-01-02T16:34:03 ID: 62649 Page 3 of 5 Reg: 212-NO07042OB-000000000-0000 Registration Date/Time: 2012/12/13 18:32:19 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential - (Part, 4 of 5) CF-1 R Project Name MOUNTAIN - PLAN Z Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family 0 Existing+ Addition/Alteration/2013 7DateCORAL OPAQUE SURFACE DETAILS - Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Wall 81 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Wall 110 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 258 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Roof 1,117 0.028 R-38 0 0 New 4.2.2-A 19 Conditioned Area Wall 462 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 182 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Roof 625 0.028 R-38 0 0 New 4.2.2-A 19 Conditioned Area Wall 245 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Wall 462 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Roof 966 0.028 R-38 0 0 New 4.2.2-A19 Conditioned Area FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC4 Azm Status Glazing Type Location/Comments 1 Window 2.8 0.290 NFRC 0.33 NFRC 270 New - Anderson Double Pane Low E(1 Conditioned Area 2 Window 220.2 0.560 NFRC 0.32 NFRC 90 New Fleetwood Conditioned Area 3 Window 137.0 0.560 NFRC 0.32 NFRC 90 New Fleetwood Conditioned Area 4 Window 35.3 0.380 NFRC 0.34 NFRC 90 New Fleetwood(1) Conditioned Area 5 Window.-- , _ 28.2 0.290 NFRC _0.29 NFRC,,,,,, .90 New „•a.,,: Piastpro Low E _ , ., , Conditioned Area 6 Window -22.0 0.290 NFRC',. :- 0.33' NFRC `180 New 2 3 Anderson Double Pane Low E(1 Conditioned Area 7 Window '22.0 0.290 NFRC 0.33 NFRC 180 New �.- Anderson Double Pane Low E(1 Conditioned Area 8 Window 22. - ,::'0.310 NFRC: 0.31 NFRC . •{ 0 New,- 'Anderson Double Pane Low E(3 Conditioned Area 9 Window 22.0 ; 0,310 NFRC 0.31 NFRC 0 New .;,`': Anderson Double Pane Low E(3 Conditioned Area, .a 10 . Window ,# 10.4 - 0.290. NFRC 0.33 NFRC ,270 New I ., Anderson Double Pane Low. E(1 Conditioned Area 11 Wndow W.' ' 10.4 -0.290 NFRC Y' 0.33 NFRC,;- :`-..r 270' New. ^- Anderson Double Pane Low E(1.Coriditioried Area °) 12 Window 13.3 0.280 NFRC 0.28 NFRC 270 New Andersen Double Pane Low E(2 Conditioned Area 13 Window 13.3 0.280 NFRC 0.28 NFRC 270 New Andersen Double Pane lo-wE(2 Conditioned Area 14 Window 10.3 0.290 NFRC 0.33 NFRC r 270 New Anderson Double Pane Low E(1 Conditioned Area 15 Window 22.0 0.310 NFRC + 0.31 NFRC _ 180 New Anderson Double Pane Low E( Conditioned Area 16 Window 22.0 0.310 NFRC 0.31 NFRC 180 New Anderson Double Pane Low E( Conditioned Area (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hanq Left Fin Right Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 1 Roll -down Blind or Slats 0.13 2 Bug Screen 0.76., 3 Bug Screen 0.76 4 Roll -down Blind or Slats 0.13 5 Bug Screen 0.76 6 Roll -down Blind or Slats 0.13 7 Roll -down Blind or Slats 0.13 8 Roll -down Blind or Slats 0.13 - 9 Roll -down Blind or Slats 0.13 10 Roll -down Blind or Slats 0.13 11 Roll -down Blind or Slats 0.13 12 Roll -down Blind or Slats 0.13 13 Roll -down Blind or Slats 0.13 14 Roll -down Blind or Slats 0.13 15 Roll -down Blind or Slats 0.13 16 Roll -down Blind or Slats 0.13 EneTjtiPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:34:03 ID: 62649 Page 4 of 5 Reg: 212-NO07042OB-000000000-0000 Registration 6ate/Time:;2012/12/13 18:32:19, HERS Provider: CalCERTS,• Inc Electronically Filed by Gangyi.Zhou and'Authenticated at CalCERTS.com - 1-/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN Z Building Type © Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 BUILDING ZONE INFORMATION System Name Zone Name. Floor Area ft Volume Year Built New Existing Altered I -Removed 3.5T Carrier COMMON AREA 1,117 15,638 3.5T Carrier Master Bed 625 5,625 ' Bedrooms/Library 966 8,694 Totals 2,7081 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Type Min. Eff. Thermostat Type Status 3.5T Carrier 1 - Central Fumace . 80% AFUE —Cooling Split Air Conditioner 15.5 SEER Setback New 3.5T Carrier 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 3 w yr ,' HVAC DISTRIBUTION t: 1 i.r ay; •,�> . System Name f a, µHeatin2 �„ r Cooling s �r ,;•. - Duct Location a;'DuctFir*'" "R-Value s.° Ducts.w,.- Tested? Status 3.5T Carrier Ducted Ducted Conditioned 6.0 m New 3.5T Carrier ducted Ducted Conditioned 6.0 fZl New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input, Btuh Tank Cap. al Energy Factor or RE . Standby Loss or Pilot Ext. Tank Insul. R- Value - Status RTG-95DVN 1 Instant Gas : Kitchen Pipe Ins 199,900 0 0.84 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft c O �6 0 U) a — System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:34:03 ID: 62649 Page 5 of 5 Reg: 212-NO07042OB-000000000-0000 Registration Date/Time: 2012/12/13 18:32:19 HERS Provider: CalCERTS, Inc MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name CORAL MOUNTAIN - PLAN Z Date 11212013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. " 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factor -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoff User Number: 8165 Run Code: 2013-01-02T16:34:03 ID: 62649 Page 8 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 11212013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CIVIC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 8165 Run Code: 2013-01-02T16:34:03 ID: 62649 Page 9 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 11212013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFIVI at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130 d . §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoR User Number: 8165 RunCode: 2013-01-02T16:34:03 ID: 62649 Page 10 of 14 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 11212013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard % Better* Space Heating 4.32 4.75 -0.43 30.48 / 101.93 = 29.9 Space Cooling 70.18 41.77 28.41 Coolin Standard Heat Rejection 0.00 0.00 0.00 28.41 / 70.18 = 40.5 Indoor Fans 13.96 15.33 -1.38 Incentive Eligibility Yes No Domestic Hot Water 13.47 9.59 3.88 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 2,708.0 fta TOTALS: 101.93 7f.45 30.48 Number of Bedrooms = 3 Energy Star V3 Target = 19 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Mar in Facing North Peak Demand kW 8.4 1 5.6 2.8 EStandard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms kWh (therms) kWh (therms) Space Heating 0.00 73.17 0.00 80.61 0.00 -7.44 Space Cooling 8,586.40 0.00 5,018.89 0.00 3,567.51 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,855.12 0.00 1,990.31 0.00-135.19 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 10,441.52 318.51 7,009.20 254.94 3,432.32 63.57 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) 2s.s i° �� Rate from Ste 3 o.8s X1 3,432.32 Subtotal Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program requirements to qualify. Natural Gas 2s.s °i �� $/kW kW 3.42 x 63.57 = $217 Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific Gas and Energy Star Incentive n/a x 10% a , Electric Company Green Home Incentive n/a x 10% SOUTMF.RN CALIFORNIA ED I S O N' Compact Home Incentive n/a x 15% An EDISO-N INTi=FV,17'IOA'.th• Campary AV Photovoltaic Incentive n/a x Mf DC Rating kW A Sernpra Energyutiry° Air" NSHP �� �°trr� lifd ! i s ,\ Total 0 �m°ar d�r���d hO��rw A *Sempri E'nergy°rnv � Better than in this equation is limited to 45 % EnergyPro 5.1.7. 7 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:34:03 1D: 62649 Page 11 oft UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 11212013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Mar in Standard % Better' Space Heating 4.32 3.74 0.57 23.81 / 1 101.93 = 23.4 Space Cooling 70.18 47.47 22.71 Cooling Standard Heat Rejection 0.00 0.00 0.00 22.71 / 1 70.18 = 32.4 Indoor Fans 13.96 17.31 -3.36 Incentive Eligibility Yes No Domestic Hot Water 13.47 9.59 3.88 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 2,708.0 ft' TOTALS: 101.93 78.12 23.81 Number of Bedrooms = 3 Energy Star V3 Target = 19 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Facing East Peak Demand kW 8.4 5.6772.7 EStandard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms (kWh) (therms) (kWh) therms Space Heating 0.00 73.17 0.00 63.54 0.00 9.63 Space Cooling 8,586.40 0.00 6,149.08 0.00 2,437.33 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,855.12 0.00 2,382.99 0.00-527.87 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.001 0.00 0.00 0.00 0.00 TOTALS: 10,441.52 318.51 8,532,0712237.88 r 1,909.45 80.63 (Afle POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive savings on this report are available only through the California from ste 2) Electricity (kWh) 23.4 -�' . Rate from Ste 3 0.67 x 1,909.45 Subtotal Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program Natural Gas 23.4 i° �� $/kW kW x requirements to qualify. 2.68 80.63 $216 Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific Gas and Energy Star Incentive n/a x 10% Electric Company Green Home Incentive n/a x 10% SQUTNERV CALIFORNIA ED I S O N° Compact Home Incentive n/a x 15% All. Comp ry ,Ar G Photovoltaic Incentive n/a x ML DC Rating kW 9 A Sernpra Energyuerty" `, NSHP call Orn a Total $1,s11 C- advanced hor nes- A *tiempm Fnergymaay- *% Better than in this equation is limited to 45% EnergyPro5.1.7.7 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:34:03 ID: 62649 Page 12 of 14 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 11212013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard %Better' Space Heating 4.32 4.14 0.18 1 21.04 / 101.93 = 20.6 Space Cooling 70.18 49.20 20.98 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 20.98 / 70.18 = 29.9 Indoor Fans 13.96 17.95 -4.00 Incentive Eligibility Yes No Domestic Hot Water 13.47 9.59 3.88 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 2,708.0 fr2 TOTALS: 101.93 80.88 21.04 Number of Bedrooms = 3 Energy Star V3 Target 19 - • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Mar in Facing South Peak Demand kW 8.4 6.21 12.2 EStandard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms (kWh) (therms) (kWh) therms Space Heating 0.00 73.17 0.00 70.09 0.00 3.08 Space Cooling 8,586.40 0.00 6,293.20 0.00 2,293.20 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,855.12 0.00 2,445.59 0.00-590.47 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 10,441.52 318.51 r 8,738.79 244.42 1,702.73 17 74.08 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) Rate from Ste 3 X1 1,702.73 Subtotal Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program requirements to qualify. Natural Gas 2o.s °i° � $/kW kW 2.3s x 74.08 $175 Potential incentives are $/therm therm subject to program limitations Base Incentive Gas and Energy Star Incentive n/a x 10% alPacific Electric Company Green Home Incentive n/a x 10% SOIJiHFIZIN CALIFORNIA ED I S O N* Compact Home Incentive n/a x 15% All CDISO rlrtxtaxro.�.u!Ca,npanp Photovoltaic Incentive n/a x E DC Rating kW 3 A W'Sempra Energyutirty" NSHP W. califdrnia Total ''��'q � / M /''�f /'�;'�'1 advanced Sempra fnergymaiy' ' % Better than in this equation is limited to 45 % EnergyPro5.1.7. 7 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:34:03 ID: 62649 Page 13 oTlfl UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 1/2/2013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard % Better* Space Heating 4.32 4.58 -0.26 20.32 / 101.93 = 1 19.9 Space Cooling 70.18 49.51 20.67 Coolin Standard Heat Rejection 0.00 0.00 0.00 20.67 / 70.18 = 1 29.5 Indoor Fans 13.96 17.93 -3.97 Incentive Eligibility Yes No Domestic Hot Water 13.47 9.59 3.88 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 2,708.0 R2 TOTALS: 101.93 81.60 20.32 Number of Bedrooms = 3 Energy Star V3 Target = 19 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Facing West Peak Demand kW a.4 7.0 77T4 EStandard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms kWh therms (kWh) therms Space Heating 0.00 73.17 0.00 77.64 0.00 -4.46 Space Cooling 8,586.40 0.00 5,887.41 0.00 2,698.99 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,855.12 0.00 2,288.07 0.00-432.95 0.00 Domestic Hot Water E10,441.52 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 318.51 8,175.48 251.97 2,266.05 1 66.54 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) Rate from Ste 3 Subtotal X 1 2,266.05 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program Natural Gas 1s.s % �� $/� kW 2.2a x ss.5a requirements to qualify. $152 Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific Gas and Energy Star Incentive n/a x 10% Electric Company Green Home Incentive n/a x 10% SOU1I•IEI2N CALIFORNIA ED I S O N' Compact Home Incentive n/a x 15% An EDISON IATUR\ O'11AAff Compan, Photovoltaic Incentive n/a x AV agi DC Rating kW 9 A SernpraInergy.tnay' � NSHP W, cafi Ornia Total fnmpmry (�pj{;(�]% �j�( advanced �! 1��� �O���fM A �Sempra [nergyuomy' Better than in this equation is limited to 45 EnergyPro5.1.7.7 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:34:03 ID: 62649 Page 14 of 14 BUILDING ENERGY ANALYSIS REPORT PROJECT: CORAL,MOUNTAIN ACCESSORY A LA QUINTA, CA Project Designer: POON DESIGN INC 315 S. Beverly Drive, Suite 206 Beverly Hills, CA 90212 310-277-8855 Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521612 Job Number: * ExP i 62649 F OFOR Date: ,1 /3/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 5.1 by Energ Soft User Number. 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 TABLE OF CONTENTS Cover Pa9 e 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary 8 Form UTIL-1 R Utility Incentive Worksheet 11 EnergyPro 5.1 by EnergySoft Job Number ID: 62649 User Number: 8165 M Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Siqned at CalCERTS.com by Russell Jones (Alta Verde Buildersl 1/3/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5) CE-1 R Project Name CORAL MOUNTAIN ACCESSORY A Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 184 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY. CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area 'Special Construction Type Cavity (ft�) Features (see Part 2 of 5) Status Wall Wood Framed R-21 430 New Roof Wood Framed Rafter R-38 184 New t FENESTRATION U- Exterior Orientation Area(e) Factor SHGC. Overhang. Sidefilns.- Shades Status Rear (E) 48.0 0.290 0.33 none none Bug Screen New Rear(E) .• _. , 28.2 0.290���r,•,r0.29, .none. „�-,,,rnone c>.,�, —,Bug Screen .c�,,• New s "'444 ,,J'F J e..t 1 , z,.._ .,�!'7` � > .?y + � ', a j t, }•-f. per„ ;. Y HVAC SYSTEMS Qty. Heating Min. Eff' Cooling Min. Eff Thermostat Status 1 Split Heat Pump 7.70 HSPF Split Heat Pump 15.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location'- R-Value Status 1.5T Carrier Ducted Ducted, Conditioned 6.0 New WATER HEATING ' Qty. Type Gallons Min. Eff Distribution Status 1 Instant Gas 0 0.84 Kitchen Pipe Ins New Energ Pro 5.1 by EnergySoft User Number.: 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Page 1 of 5 Reg: 212-N0071869B-000000000-0000 Registration Date/Time: 2012/12/20 18:05:29 HERS Provider: CalCERTS, Inc t. Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Siqned at Ca10ERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN ACCESSORY A Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items'require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. f HERS REQUIREDYERIFICATION °'? � Items in this'section'require field testing acid/or verificat o by a ce )fied H'ERS',Rate .-The•inspector. m st receive a completed CF-4R form for each of the measures listed below for final to be given. - The Cooling System 1.5T includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. t The HVAC System 1.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System 1.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 1.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 1.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. ` A EnergyPro 5.1 by EnerqySoft User Number: 8165 RunCode: 2013-01-03T17:27:07 1D: 62649 ' Page 2 of 5 Reg: 212-N0071869B-000000000-0000 Registration Date%Time: 2012/12/20 18:05:29 HERS Provider: CalCERTS,-Inc Electronically riled by Gangyi Zhou and Authenticated at Ca10ERTS.com 1/3/2013 Electronically Signed at Ca10ERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 � PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date CORAL MOUNTAIN ACCESSORY A ❑ Multi Family ❑ Existing+ Addition/Alteration 1/3/2013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV kBtu/ft2- r North - East South West Space Heating 5.89 3.49 2,40 4.07 1.82 4.16 1.74 3.07 2.82 Space Cooling 156.96 148.56 8.40 152.18 4.76 - 121.16 35.80 142.49 14.47 Fans 32.35 46.61 -'14,27" 46.41 14.07 37.53 -5,18 44.65 -12.30 Domestic Hot Water 1 110.17• 50.96 59.21 50.96 59.21 50.96 59.21 50.96 59.21 Pumps 0.00' 0.00 0.00 0.00 a0b 0.00 0.00' 0.00 0.00 Totals 305.37 249.62 55.75 253.63 51.74213.80 91.56 241.17 64.20 Percent Better Than Standard: 18 3 % . 16.9 % 30.0 % 21.0 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00, ._ (w) 162 0 Fuel Available at Site: Natural Gas (N) 91 0 Raised Floor Area: - 0` (E) 162 76 Slab on Grade Area: 0 (S) 91 0 Average Ceiling Height: r 90. Roof 184 0 Fenestration Average U-Factor: 0.29 - ,TOTAL: 76 _ 'Average SHGC: 0.32 Fenestration/CFA Ratio: 41.4 % REMARKS `''*` ^-�. �F .`.' 11 1,� s v r".., F, �.�., . J' rti r, v' ' V !.� x. ti 'fix.. ;' `^ s� • .. .. - .. - Y STATEMENT OF COMPLIANCE -t This certificate of compliance lists the building features and specifications 'heeded to comply with Title 24, Parts' 1 the Administrative Regulations and Part 6 the - Efficiency Standards of the California Code of Regulations. - The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GMEP Engineers Address 4400 Campus Drive - Name Gan9*Y i Zhou `' 11312013 City/State/Zip Newport Beach, CA 92660 phone 9497521612 Signed Date The individual with overall design responsibility hereby certifies ,that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge: insulation installation quality., and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company POON DESIGN INC Address 315 S. Beverly Drive, Suite 206 Name C25529 1 /7/13 City/State/Zip Beverly Hills, CA 90212 Phone 310-277-8855 Signed. license # Date EnergyPro 5.1 by EnergySoft User Number. 8165 RunCode: 2013-01.03T17:27:07 ID: 62649 Page 3 of 5 Rey: 212-i40071.E69B-00000oo00-0000 Registration Date/Time: 201.2/12/20 18:05:29 HERS Provider: Ca.10ERTS, Inc T Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Siqned at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN ACCESSORY A Building Type m Single Family ❑Addition Alone ❑ Multi Family ,❑ Existing+ Addition/Alteration Date 1/3/2013 OPAQUE SURFACE DETAILS - Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Wall 91 0.069 R-21 - 0 90 New 4.3.1-A6 Conditioned Area . Wall 91 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Wall 86 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area ' Wall 162 0.069 R-21 270 90 New 4.3.1-A6 • Conditioned Area Roof 184 0.028 R-38 0 0 New' 4.2.2-A19 Conditioned Area FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments i Window 24.0 0.290 NFRC 0.33 NFRC 90 New Andersen Double Pane Low E Conditioned Area 2 Window 24.0 0.290 NFRC 0.33 NFRC 90 New Andersen Double Pane Low E Conditioned Area 3 Window 28.2 0.290 NFRC 0.29 NFRC 90 New Plastpro Low E Conditioned Area cti - f (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value " EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin H t Wd Len H t LExt RExt Dist Len Hat Dist Len H t. i Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Page 4 of 5 Reg: 212-N0071869B-000000000-0000 Registration Date/Time: 2012/12/20 18:05:29 HERS Provider: CalCERTS, Inc i Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Siqned at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF'COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name CORAL MOUNTAIN ACCESSORY A Building Type • ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/3/2013 BUILDING ZONE INFORMATION S stem.Name... Zone Name.. ,. Floor Area ft - Year Built New Existing Altered Removed . _Volume•.• 1.5T Carrier AREA 184 1,656 ' ; r r r Totals 1 1841 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type— Status 1.5T Carrier 1 Split Heat Pump 7.70 HSPF Split Heat Pump 15.0 SEER Setback New HVAC DISTRIBUTION, System Name Heating Cooling Duct Location . Duct 4 R-Value V Ducts Tested? Status 1.5T Carrier Ducted Ducted , Conditioned 6.0 fZ1 New ❑ WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated • Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status RTG-95DVN 1 Instant Gas Kitchen Pipe Ins 199,900 0 0.84 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 c Q — System Name .. Pipe Len th Pipe Diameter Insul. Thick. Qt . . HP Plenum Outside Buried El EnergyPro 5.1 by EnergySoft User Number: 8165 Run Code: 2013-01-03T17:27:07 ID: 62649 Page 5 of 5 Reg: 212-N0071869B-000000000-0000 Registration Date/Time: 2012/12/20 18:05:29 HERS Provider: CalCERTS, Inc MANDATORY MEASURES SUMMARY: Residential (Pade 1 of 3 MF-1 R Project Name CORAL MOUNTAIN ACCESSORY A Date 1 11312013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1R-ALT Form) shall supersede.the items marked with.an asterisk(*) below. This Mandatory.Measures Summary.shall.be incorporated _ into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-1 11 (a). 117: Exterior doors and windows are weather- stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factor -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5. i by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Page 8 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A 11312013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heatin . 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 .: Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire as specified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 150 k . 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoR User Number: 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Page 9 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A 11312013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy: EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exception) to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130 d . §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoR User Number: 8165 Rur Code: 2013-01-03T17:27:07 ID: 62649 Page 10 of 14 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A 11312013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed. Mar in margin Standard % Better' Space Heating 5.89 3.49 2.40 55.75 / 305.37 = 18.3 % Space Cooling 156.96 148.56 8.40 Coolin Standard Heat Rejection 0.00 0.00 0.00 8.40 / 1 156.96 = 5.4 Indoor Fans 32.35 46.61 -14.27 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 184.0 ft2 TOTALS: 305.37 249.62 55.75 Number of Bedrooms = 1 Energy Star V3 Target = 15 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing North Peak Demand kW 1.1 1 1.01 1 0.1 EStandard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms (kWh) (therms) (kWh) (therms) Space Heating 102.31 0.00 60.61 0.00 41.70 0.00 Space Cooling 1,431.36 0.00 1,426.19 0.00 5.18 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 477.44 0.00-160.30 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps o.o0 0.00 0.00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1,964.24 62.94-113.42 73.52 - • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24` Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) Rate from Ste 3 x 0.00 Subtotal = $o Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program Natural Gas 18.3 % �� $/ kW kW X requirements to qualify. 2.10 73.52 $154 Potential incentives are $/therm therm subject to program limitations Base Incentive = s1s3 Pacific Gas and Energy Star Incentive n/a x 10% Electric Company Green Home Incentive n/a x 10% SOUTHFIhv CALIFOf2NIA ED I SO N° Compact Home Incentive $163 x 15% = 824 An EDISON I.Y7"L'B:\.MO.Vil' Compm:p Photovoltaic Incentive n/a x AV sf DC Rating kW AW5eril Ira t-ner"Iyutility' NSHP �fin al1f0na Total = g1s7 (-.Pay advanced ypyes- n -Sempra Energyuurty- *% Better than in this equation is limited to 45% EnergyPro5.1. 7. 7 by EnergySoff User Number- 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Page 11 of 14 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A 1/3/2013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Mar in Standard % Better' Space Heating 5.89 4.07 1.82 51.74 / 1 305.37 = 16.9 % Space Cooling 156.96 152.18 4.78 Cooling Standard Heat Rejection 0.00 0.00 0.00 4.78 / 1 156.96 = 3.0 Indoor Fans 32.35 46.41 -14.07 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 184.0 ffz TOTALS: 305.37 253.63 51.74 Number of Bedrooms = 1 Energy Star V3 Target = 15 % ANNUAL SITE ENERGY USE 5pm Standard Pro osed Mar in rPeak Facing East kW 1.1 1.2 0.2 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) (therms) kWh (therms) (kWh) (therms) Space Heating 102.31 0.00 69.03 0.00 33.28 0.00 Space Cooling 1,431.36 0.00 1,348.28 0.00 83.08 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 441.12 0.00-123.98 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS:El,850.82 136.46 1,858.43 62.94 7.61 1 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24` Incentive Savings on this report are available (from step Rate from Ste 3 Subtotal only through the California Electricity (kWh) 16.9 % o.a8 x o.00 = $o Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 1s.s i° Sa x NOT GUARANTEED. Projects must meet all other program Natural Gas $/� kW X requirements to qualify. 73.52 $143 Potential incentives are $/therm therm subject to program limitations Base Incentive = 8143 Pacific Gas and Energy Star Incentive rUa x 10% Electric Company Green Home Incentive n/a x 10% SOU'iHrMN CAI_IrORNIA ED I S O N' Compact Home Incentive 8143 x 15% n En1SO.N 1. rCR\A7'10NA! Camp:,,, � Photovoltaic Incentive n/a x SDGE AiENWA DC Rating kW (IYSempra F.nergyutirly" NSHP � califdrn a :. Total = $1sa Ce��y advanced hot 'ISempra 111esr� A ( Encrgyu,iny' *% Better than in this equation is limited to 45 % EnergyPro 5.1.7.7 by EnergySoft User Number: 8165 Run Code: 2013-01-03T17:27:07 ID: 62649 Page 12 of 14 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A 11312013 •I ANNUAL TDV ENERGY USE k13tu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Mar (n Standard % Better* Space Heating "' 5.89 4.16 1.74 91.56 / 305'37 c 30.64 Space Cooling 156.96 121.16 35.8o Cool* n Standard Heat Rejection 0.00 0.00 0.00 35.80 / 156.96 = 22.8 Indoor Fans 32.35 37.53 5.18 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ ❑ Conditioned Floor Area = 184.0 ftI TOTALS: 305.37 213.80 91.56 Number of Bedrooms = 1 Energy Star V3 Target = 15 ANNUAL SITE ENERGY USE Ave5pm Standard Pro osed Mar in 7Demand Facing South PekW 1.1 0.90.2 EStandard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) (therms) (kWh) (therms) kWh (therms) Space Heating 102.31 0.00 70.33 0.00 31.98 0.00 Space Cooling 1,431.36 0.00 1,090.26 0.00 341.10 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 362.67 0.00 -45.53 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps EE1,850.82 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 136.46 1,523.27 62.94 327.55 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24` Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) 30.0 �/ Rate from Ste 3 Subtotal o.8s x 327.55 = $282 Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) 30.0 % �' 150 x NOT GUARANTEED. Projects must meet all other program Natural Gas 30.0 Rio �� $/� kW x requirements to qualify. 3.43 73.52 $252 Potential incentives are $/therm therm subject to program limitations Base Incentive = $5s4 Pacific Gas and Energy Star Incentive n/a x 10% l Electric Company Green Home Incentive n/a x 10% SOU11HINN CALIFORNIA • E D I S O i ale Compact Home Incentive $5s4 x 15% 1n l.'i)(SON !.�'i'i:F\� iT((),\)SI Q.vnpzm Photovoltaic Incentive n/a x �,0 SD E ibime DC Rating kW A Sernpra f::nergi- utitity' NSHPur c.�` rrlt 4N,,Total f�/ya]lifdy��{r 1ta■/�/i■ = $s4s advanced �O��fM A WSempra fnergyojity_ Better than in this equation is limited to 45% EnergyPro 5.1.7.7 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Page 13 of 14 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A 11312013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard % Better' Space Heating 5.89 3.07 2.82 64.20 / 305.37 = 21.0 % Space Cooling 156.96 142.49 14.47 Coolin Standard Heat Rejection 0.00 0.00 0.00 14.47 / 156.96 = 9.2 Indoor Fans 32.35 44.65 -12.30 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 184.0 ft2 TOTALS: 305.37 241.17 64.20 Number of Bedrooms = 1 Energy Star V3 Target = 15 % ANNUAL SITE ENERGY USE Ave5pm Standard Pro osed Mar in 7Deand Facing West PekW 1.1 o.s o.2 EStandard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) (therms) (kWh) (therms) (kWh) therms Space Heating 102.31 0.00 54.02 0.00 48.30 0.00 Space Cooling 1,431.36 0.00 1,382.24 0.00 49.12 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 461.10 0.00-143.96 0.00 Domestic Hot Water 0.00 136.46 0.00Q 0.00 73.52 Pumps 0000.00 0.00 0.00 0.00TOTALS: 1,85082 136.46 1,897.36 -46.54 1 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive savings on this report are available only through the California from ste 2) Electricity (kWh) 21.0 /0 Rate from Ste 3 o.so x o.00 Subtotal = $o Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program requirements to qualify. Natural Gas 21.0 °io �� $/kW kW 2.4o X 73.52 $176 Potential incentives are $/therm therm subject to program limitations Base Incentive = $1s7 Pacific Gas and Energy Star Incentive n/a x 10% Y Electric Company Green Home Incentive n/a x 10% SOUTHERN CALIFORNIA E D I S {J N' Compact Home Incentive $197 x 15% G,� Photovoltaic Incentive n/a x si DC Rating kW A(i�eSE?mpraEnergy oi,y` NSHP �Q Ca lfdrnia tl Total - 5227 DanY advanced h6mc M A *, sempri fnergy,nicty• `% Better than in this equation is limited to 45 % EnergyPro 5.1.7. 7 by EnergySoft User Number: 8165 Run Code: 2013-01-03T17:27:07 ID: 62649 Page 14 of 14 BUILDING ENERGY ANALYSIS REPORT PROJECT: CORAL MOUNTAIN ACCESSORY A OPTION LA QUINTA, CA Project Designer: POON DESIGN.INC 315 S. Beverly Drive, Suite 206 Beverly Hills, CA 90212 310-277-8855 Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521612 �. �0 9ROFEsgi� vPNGV1 Zy�F - o y Job Number: M3 G z • % m 62649 .. ExP Date: CALIFORN�P 1 /3/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 5.1 by Energ Soft User Number: 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary, 8 Form UTIL-1 R. Utility Incentive Worksheet 11 e fi EnergyPro 5.1 by EnergySofl Job Number: ID: 62649 User Number: 8165 Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name CORAL MOUNTAIN ACCESSORY A OPT Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 184 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area *Special Construction Type Cavity (ft) Features'(see Part 2 of 5) Status Wall Wood Framed R-21 373 New Roof Wood Framed Rafter R-38 184 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Rear (E) 133.4 0,560 0.32 none none Roll -down Blind or Slats New 'L d. I P .,7M'£$ 7� "4 r"*„ :�% �' •A,� ,.,F•�i'i i � 'r � "'W�� F =.l �' s. J e. Vw� � r„_ •'.,, . t .r '*-. ••ram,".... ,.Y -�.d; "; e f . '�' ,,'�'`!'t HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 7.70 HSPF Split Heat Pump 15.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating, Cooling Duct Location R-Value Status 1.5T Carrier Ducted Ducted Conditioned 6.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution' Status 1 Instant Gas 0 0.84 Kitchen Pipe Ins New ,c Energ Pro 5.1 by EnergySoft User Number. 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 Page 1 of 5 Reg: 212-NO07187OB-000000000-0000 Registration Date/Time: 2012/12/20 18:06:24 HERS Provider: CalCERTS, Inc -. v Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Siqned at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN ACCESSORY A OPT/ Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/3/2013 SPECIAL FEATURES, INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. r � • l F HERS REQUIRED„VERIFICATION Y `^"\ 5 %tip Items in this section require field testing -and/or verification:by a certified'HERS Rater.'The inspector must receive a com leted_CF-4R form for each of the measures listed below for final to be given. . The Cooling System 1.5T includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 1.5T Carrier includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System 1.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System 1.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. . The HVAC System 1.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 1.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro 5.1 bv EnergySoft User Number: 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 Page 2 of 5 Reg: 212-NO07187OB-000000000-0000 Registration Date/Time: 2012/12/26 18:06:24 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Signed at Ca10ERTS.com by 'Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family O Addition Alone Date CORAL MOUNTAIN ACCESSORY A OPTI ❑ Multi Family ❑ Existing+ Addition/Alteration 11312013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV (kBtu/ft2 r) North East South West Space Heating 5.89 11.74 -5.85 12,29 -6.39 12,52 -6.63 11.21 -5.32 Space Cooling 156.96 144.11 12.85 150.45 6.51 132.54 24.42 142.79 14.17 Fans 3Z35 33.45 -1.10 34.45 -2.11 30.69 1.66 33.14 -0.80 Domestic Hot Water 110.17 50.96 59.21 50.96 59.21 50.96 59.21 50.96 59.21 Pumps 0.00 0.00 0.00 0.00 0,00 0.00 0,00 0.00 0.00 Totals 305.37 240.25 65.12 248.15 57.22 226.71 78.66 238.10 67.26 Percent Better Than Standard: 21.3 % 18.7 % 25.8 i 22.0 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four Orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 !iM 162 0 Fuel Available at Site: Natural Gas (N) 91 0 Raised Floor Area: 0 (E) 162 133 Slab on Grade Area: . 0 (S) 91 0 Average Ceiling Height: 9.0 Roof 164 0 Fenestration Average U-Factor: 0.56 TOTAL: 133 Average SHGC: 0.32 Fenestration/CFA Ratio: 72.5 % REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GMEP Engineers Address 4400 Campus Drive Name Gan i Zhou 11312013 9Y Cif/State2ip Newport Beach, CA 92660 Phone 9497521612 Signed Date m........................_....................................._............................................._........................_...._.........._.............................,............................_.........................................................._.._._...._.............................,......... The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets: with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company POON DESIGN INC Address 315 S. Beverly Drive, Suite 206 Name C25529 1 /7/13 City/State.2ip Beverly Hills, CA 90212 Phone 310-277-8855 Signed License 8 Date EnergyPro 5.1 by EnerqySoft user Number. 8165 Run Code: 2013.01-03T17.28:21 1D: 62649 Page 3 of 5 Reg: 212-NO0718708-000000000-0000 Registration Date/Time: 2012/12/20 18:06:24 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN ACCESSORY A OPTI Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 111312013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interiorl Frame wall 91 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 91 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Wall 29 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 162 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Roof . 184 0.028 R-38 0 0 New 4.2.2-A19 Conditioned Area FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 133.4 0.560 NFRC 0.32 NFRC 90 New Fleetwood Slider Conditioned Area V.i. 1k (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ' ID Exterior Shade Type SHGC Window Ove hanq Left Fin Ri ht Fin Hq1t Wd Len H t LExt RExt Dist Len Hot Dist Len H t 1 Roll -down Blind or Slats 0.13 EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 Page 4 of 5 Reg: 212-NO07187OB-000000000-0000 Registration Date/Time: 2012/12/20 18:06:24 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name . • CORAL MOUNTAIN ACCESSORY A OPTI Building Type © Single Family ❑ Addition Alone , ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 BUILDING ZONE INFORMATION System Name ' Zone Name Floor Area ft Volume Year Built New. Existing Altered Removed 1.5T Carrier AREA 184 1,656 Totals i 184 -0 0 ' 0 HVAC SYSTEMS System Name Ot . Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status 1.5T Carrier 1 Split Heat Pump 7.70 HSPF Split Heat Pump 15.0 SEER Setback New .. ti. 7.7 - .. .. HVAC DISTRIBUTION •'+ `_� `. r� ! - . , 1 3 a: r It System Name Heating Cooling Duct Location Duct! R-Value (..' Ducts Tested? Status 1.5T Carrier Ducted Ducted Conditioned 6.0 m New WATER HEATING SYSTEMS S stem Name Ot . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status RTG-95DVN 1 Instant Gas Kitchen Pipe Ins 199,900 0 0.84 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o a a — System Name Pipe Length Pipe Diameter Insul. Thick. Ot . HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 Page 5 of 5 Reg: 212-N0071870B-000000000-0000' Registration Date/Time: 2012/12/20 18:06:24 HERS Provider: Ca10ERTS, Inc r MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name CORAL MOUNTAIN ACCESSORY A OPTION 1 Date 11312013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate t e and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. " 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. ` 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent 1-1-factor. 150 f : Air retarding wrap is tested, labeled, and installed accordin to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 erm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is — equipped with'a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket; when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation liaving an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatingsections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4.. Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoR User Number: 8165 Run Code: 2013-01-03T17:28:21 ID: 62649 Page 8 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A OPTION 11312013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heatin . 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ro rammed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 150 k . 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number. 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 Page 9 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A OPTION 11312013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130 d . §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoff User Number: 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 Page 10 of 14 UTILITY IN WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A OPTION 11312013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Mar in Standard % Better* Space Heating 5.89 11.74 -5.85 1 65.12 / 305.37 = 21.3 % Space Cooling 156.96 144.11 12.85 Cooling Standard Heat Rejection 0.00 0.00 0.00 12.85 / 1 156.96 = 8.2 Indoor Fans 32.35 33.45 1.10 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 184.0 ft2 TOTALS: 305.37 240.25 65.12 Number of Bedrooms = 1 Energy Star V3 Target = 15 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Mar in Facing North Peak Demand kW 1.1 1.0 F 0.1 ENERGY COMPONENT Standard Proposed Margin Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms (kWh) (therms) (kWh) (therms) Space Heating 102.31 0.00 204.93 0.00-102.62 0.00 Space Cooling 1,431.36 0.00 1,287.86 0.00 143.50 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 322.17 0.00 -5.03 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.00 0.00 0.00 0.00 1 0.00 TOTALS: 1,850.82 136.46 1,814.96 62.94 35.85 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) 21.3 i° �� Rate from Ste 3 o.s1 X 35.85 Subtotal = $22 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 21.3 % �� 106 x NOT GUARANTEED. Projects must meet all other program requirements to qualify. Natural Gas 21.3 °i° �' $/� kW 2.44 x 73.52 $179 Potential incentives are $/therm therm subject to program limitations Base Incentive = $212 Pacific Gas and Energy Star Incentive n/a x 10% Electric Company Green Home Incentive n/a x 10% so"THERN CALIFORNIA ED I S O N Compact Home Incentive $212 x 15% GrAW Photovoltaic Incentive n/a x sL DC Rating kW 9 A Sernpra Energy utility' `. NSHP � rr't califdt � is �� �; Total = S2aa ,.., advanced homes V A asempra Enersyusi`y- `% Better than in this equation is limited to 45 % EnergyPro5.1.7. 7 by EnergySoff User Number: 8165 Run Code: 2013-01-03T17:28:21 ID: 62649 Page 11 of 14 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A OPTION 11312013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Margin Margin Standard % Better' Space Heating 5.89 12.29 -6.39 57.22 / 1 305.37 = 1 18.7 % Space Cooling 156.96 150.45 6.51 Cooling Standard Heat Rejection 0.00 0.00 0.00 6.51 / 1 156.96 = 4.1 Indoor Fans 32.35 34.45 -2.11 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 184.0 ffz TOTALS: 305.37 248.15 57.22 Number of Bedrooms = 1 Energy Star V3 Target = 15 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Mar in Facing East Peak Demand kW 1.1 1.1 0.1 ENERGY COMPONENT Standard Proposed Margin Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms kWh therms kWh therms Space Heating 102.31 0.00 212.48 0.00-110.17 0.00 Space Cooling 1,431.36 0.00 1,296.99 0.00 134.37 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 320.81 0.00 -3.66 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.001 0' 001 1 0.00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1,830.28 62.94 20.53 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) 18.7 % �� Rate from Ste 3 0.54 x 20.53 Subtotal = $11 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program requirements to qualify. Natural Gas 18.7 % � $/ kW �� 2.14 X 73.52 $157 Potential incentives are $/therm therm subject to program limitations Base Incentive = $1s8 Pacific Gas and Energy Star Incentive n/a x 10% s Electric Company Green Home Incentive n/a x 10% soultlrtrN cAt.rrotr'`tn ED I S O N Compact Home Incentive $168 x 15% An EDISON INI" RVATIO:NALY cumpilm Photovoltaic Incentive G„N n/a x Ain DC Rating kW 3 nSE nrtrra f::nery usrry"t. NSHP califdr1 �`Oe� Zia Total h advanced = $1s3 n Semla pra lergymany' *% Better than in this equation is limited to 45% EnergyPro 5.1.7.7 by EnergySoff User Number: 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 Page 12 oftfl UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A OPTION 11312013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard % Better' Space Heating 5.89 12.52 -6.63 78.66 / I = 25.8 Space Cooling 156.96 132.54 24.42 Cooling Standard Heat Rejection 0.00 0.00 0.00 24.42 / 1 156.96 = 15.6 Indoor Fans 32.35 30.69 1.66 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ 10 Conditioned Floor Area = 184.0 ft2 TOTALS: 305.37 226.71 78.66 Number of Bedrooms = 1 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE erage 2pm - 5pm Standard Pro osed Mar in rPeak F8CIf1CJ SOUtI1 Demand kW 1. r 1.0 0.1 EStandard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms (kWh) therms Space Heating 102.31 0.00 215.97 0.00-113.66 0.00 Space Cooling 1,431.36 0.00 1,154.01 0.00 277.36 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 289.09 0.00 28.05 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1,659.07 62.94 191.75 73.52 •-1 POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24` Incentive Savings on this report are available only through the California from ste 2) Electricity (kWh) 25.a i° �' Rate from Ste 3 0.74 x 191.75 Subtotal = $142 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program Natural Gas 25.8 % �� $/kW kW x requirements to qualify. 2.95 73.52 $217 Potential incentives are $/therm therm subject to program limitations Base Incentive = $372 Pacific Gas and Energy Star Incentive n/a x 10% Electric Company Green Home Incentive nia x 10% SOUTHHRN C IAroRNIA ED I SO N° Compact Home Incentive $372 x 15% An E01SCl.i'!a !'ckk4TtU.1: S!! Cuntp:v:y Photovoltaic Incentive n/a x DC Rating kW f ASf?n1}ltii I:III'.i";V' utility., NSHP �caii drnia N Total = $a2s � advanced homes" A A SCmpra Energyu:aav' '% Better than in this equation is limited to 45 % EnergyPro5.1.7.7 by EnergySoft User Number: 8165 Run Code: 2013-01-03T17:28:21 ID: 62649 Page 13 of 14 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A OPTION 11312013 ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in margin Standard % Better' Space Heating 5.89 11.21 -5.32 1 67.26 / 1 305.37 = 1 22.6 Space Cooling 156.96 142.79 14.17 Coolin Standard Heat Rejection 0.00 0.00 0.00 1 14.17 / 1 156.96 = 9.0 Indoor Fans 32.35 33.14 0.80 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 184.0 ft2 TOTALS: 305.37 238.10 67.26 Number of Bedrooms = 1 Energy Star V3 Target = 15 % ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing West Peak Demand kW 1.1 1.0 0.1 EStandard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) (therms) kWh (therms) (kWh) therms Space Heating 102.31 0.00 196.60 0.00 -94.28 0.00 Space Cooling 1,431.36 0.00 1,290.59 0.00 140.78 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 322.17 0.00 -5.03 0.00 Domestic Hot Water 0.00 136.46 0'00 62.94 0.00 73.52 Pumps 0.00 0.00 E8O9 L 0.00 0.00 0.00 TOTALS:El,850.82 136.46E 62.94 41.46 73.52 POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24` Incentive Savings on this report are available only through the California from ste 2� Electricity (kWh) 22.o i° Ft�ate-� from Ste 3 o.s3 x 1 41.46 Subtotal� = $2s Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) x NOT GUARANTEED. Projects must meet all other program Natural Gas 22.0 °i �� $/ kW �� X requirements to qualify. 2.52 73.52 $185 Potential incentives are $/therm therm subject to program limitations Base Incentive = $222 Pacific Gas and Energy Star Incentive n/a x 10% Electric Company Green Home Incentive n/a x 10% ' SOUTHERN CALMOUNIA Ea I S O N' Compact Home Incentive $222 x 15% An EDISON 1X1,J r\,17,10.V.10 Campm,� Photovoltaic Incentive G,0 n/a x SD E awl DC Rating kW 9 A WSeml:lra f:.nergy.t;ety' NSHP W ci i01 ! 1 a �, Total = oa y a�dvar�ced homes" S2ss n A senrpm Energyu,a1`y" '% Better than in this equation is limited to 45 EnergyPro5.1.7.7 by EnergySoff User Number. 8165 RunCode: 2013-01-03T17:28:21 1D: 62649 Page 14 of 14 � k Earth Systems Southwest 79-811 B Country Club Drive Bermuda Dunes, CA 92203 (760)345-1588 (800)924-7015 FAX (760) 345-7315 December 6, 2012'. Mr. Russell Jones Alta Verde Builders 71-905 Highway 111, Suite G Rancho Mirage, Ca 92270 Project: Tract 34243 — Coral Mountain Residential Development (formerly known as Pasatiempo) Avenue 58 West of Madison Street La Quinta, California Subject: Foundation Plan Review File No.: 10109-06 Doc. No.: 12-12-705 References: 1. Earth Systems Southwest, Geotechnical Engineering Report, Proposed 20-Acre Residential Development, 80-700 Avenue 58, West of Madison Street, La Quinta, California, File No. 10109-01, Doc No.: 05-05-771, dated May 18, 2005. 2. Earth Systems Southwest, Geotechnical Engineering Report Update with Supplemental Recommendations, Tract 34243, Pasatiempo, Avenue 58 West of Madison Street, La Quinta; California, File No.: 10109-06, Doc. No.: 11-05-752, dated May 31, 2011. In accordance with your request and authorization, Earth Systems Southwest [Earth Systems] is providing this plan review addressing foundation plans for the subject project. We have reviewed plans provided to us entitled Alta Verde Coral Mountain, Single Family -Homes, La Quinta, Ca, sheets 5-1.1, 5-1.1T, S-1.2, 5-2.1, 5-2.1T, 52.2, 53.1, S3.1T, 53.2, 54.1, S4.1T, 54.2, 55.1, SN1, SN2, SN3, SN4, PTN, PT1, PT2, PT3, SD1, SD2, HFX1, HFX2, and HFX3, dated October 24, 2012 (Building Department Set), prepared by Option One Consulting Engineers. Our review was performed from a geotechnical perspective and pertains to the plan sheets with geotechnical aspects of the project within our scope of work. Conclusions. Based upon our review from a geotechnical standpoint, it is our opinion that the plans reviewed have been prepared in substantial conformance with the intent of the recommendations in the referenced project soils reports. It is our opinion that the recommendations provided in the project soils reports remain applicable to the proposed project. Limitations Conclusions contained in this letter are based on our previously documented field observations and subsurface explorations, laboratory tests, and our present knowledge of the proposed construction. Variations in soil or groundwater conditions could exist between and beyond the exploration points. December 6, 2012 - 2 - File No.: 10109-06 Doc. No.: 12-12-705 The nature and extent of these variations may not become evident until construction. Variations in' soil or groundwater may require additional studies, consultation, and possible revisions to our recommendations. If during construction, soil conditions are encountered which differ from those described, we should be notified immediately in order that a review may be made and any supplemental recommendations provided. If the scope of the proposed construction changes from that described in this report, the conclusions and recommendations contained in this report are not considered valid unless the changes are reviewed, and the conclusions of this report are modified or approved in writing by Earth Systems. Additionally, this letter should be included with the project geotechnical (soils) report and specification documents. This report is issued with the understanding that the owner or the owner's representative has the • responsibility to bring the information and recommendations contained herein to the attention of the architect and engineers for the project. The recommendations presented within are predicated upon the recommendations presented in the referenced project soils reports. Information and recommendations presented in this supplement should not be extrapolated to other areas or be used for other projects without our prior review and response. Proper geotechnical materials observation and testing during construction is imperative to allow the Reotechnical engineer the opportunity to verify assumptions made during the design process and to verify that our -geotechnical recommendations have been properly interpreted and implemented during construction and is required by the project plans and the 2010 California Building Code. Additionally, the California Building Codes requires the testing agency to be employed by the project owner or representative (i.e. architect) to minimize a conflict of interest if employed by the contractor. Therefore, we recommend that Earth Systems be retained during the construction of the proposed improvements to observe compliance with the design concepts and geotechnical recommendations, to provide compaction testing, and to allow design changes in the event that subsurface conditions or methods of construction differ from those assumed for this commission. If we are not accorded the privilege of performing this review, we can assume no responsibility for misinterpretation of our recommendations. The above services can be provided in accordance with the Fee Schedule in effect at the time the services were performed. The geotechnical engineering firm providing tests and observations shall assume the responsibility of Geotechnical Engineer of Record. Earth Systems has. striven to provide our services in accordance with generally accepted geotechnical engineering practices in this locality at this time. No warranty or guarantee express or implied is made. Please note that it is not within our scope of work to check the reviewed documents for conformance to codes or other client and government requirements outside of the geotechnical field. Earth Systems does not practice structural engineering or architectural design. As such we make no representation as to the accuracy of dimensions, measurements, calculations, or any portion of the design. EARTH SYSTEMS SOUTHWEST t December 6, 2012 - 3 - File No.: 10109-06 Doc. No.t 1242-705 We appreciate the opportunity to provide our professional services. Please do not hesitate to contact our office if there are any questions or, comments concerning this report or its conclusions. Respectfully submitted, EssioH,� . EARTH SYSTEMS SO 06�cy No. C 704, .--'U Jam/ W No. GE 2930 �. Kevin L. Paul 913V1014 Vice President, Senior E CIVti GE 2930, CE 70094 T'�r �TEG4 oQ' F OF LTR/klp/cen Distribution: 4/Russell Jones 1/BD File Email/ Russell Jones [rjones@altaverdebulders.com] a EARTH SYSTEMS SOUTHWEST Earth Systems 1F7�, Southwest May 31, 2011 CITY OF rA QUINTA BUILDING & SAFETY DEPT. APB"' V r FOR CONSTRUCTION Alta Verde Construction, LLC. DATE BY 315 South Beverly Hills Drive, S Beverly Hills, California 90212 79-811B Country Club Drive Bermuda Dunes, CA 92203 (760)345-1588 (800) 924-7015 • ' FAX (760) 345-7315 File No.: 10109-06 E Doc. No.: 11-05-752 Attention: Mr. Andrew Adler, CEO Subject: Geotechnical Engineering Report Update with Supplemental Recommendations Project: Tract 34243 - Pasatiempo Avenue 58 West of Madison Street La Quinta, California Introduction - As requested, Earth Systems Southwest [ESSW] has reviewed the referenced documents for the purpose of updating the soils report and providing supplemental recommendations. This review included a reconnaissance of the site by our representative on May 26, 2011. Alta Verde Construction, LLC (AVC) is in the process of acquiring Tract 34243, known as Pasatiempo. Please see the referenced documents for site and project descriptions and location. In light of recent research performed in the Coachella Valley by the United States Geological Survey [USGS], and the referenced engineering bulletin distributed by the City of La Quinta . (effective date of June 18, 2010), the project site lies within an area of documented regional land subsidence. As such, the foundation recommendations in the original geotechnical engineering report have been superseded within this update. Site Conditions During our site visit, the following general conditions were.noted: ➢. All building pads have been rough -graded and sealed. ➢ Very little, if any, vegetation has grown on some lots. ➢ All streets have been finish -paved with asphalt -concrete [AC]. The streets show little, signs of distress. ➢ 'Several utility/manhole covers located in the sections of road covered with pavers have been raised to the final elevation and the concrete collars have been poured. The area surrounding the concrete collars is void of pavers. As a result additional pavers will require removal, base grade re-established and the pavers replaced "neat" against the concrete collars. OCT 26 2m L� May 31, 2011 2 File No.: 10109-06 Doc. No.: 11-05-752 ➢ Lots 40, 41, and 42 (as shown on the MDS Tentative Tract Map, Reference No. 3) contain unoccupied, completed model homes. Lot 39 contains an AC parking lot, and former sales -office trailer pad. ➢ The north -south oriented retention basin in the center of the site has been constructed with flatwork and landscape in place. The basin appears.to be performing as intended, however, the dry wells have accumulations of sediment and trash and require maintenance. The flatwork shows little signs of distress. ➢ The retention basin at the south east corner of the site (as shown on the referenced site plan) has not been constructed. ➢ Poorly compacted undocumented fill which may have been previously stockpiled was observed on Lots 1, 2, 66 through 69, and N (future retention basin). This fill was spread around the lots and loosely compacted with a wheeled vehicle. ➢ Blow sand has accumulated along the eastern boundary fence to depths of approximately 1 to 2 feet. Lesser thicknesses have accumulated along the west fence of the central retention basin. The following features are referenced on the attached Figure 1: 1. Retention basin Lot N (as shown on the referenced site plan) not. constructed. Poorly compacted undocumented fill spread around surface. 2. Poorly compacted undocumented fill spread around surface of Lots 1, 2, and 66 through 69. Gravel spoils also distributed. 3. Construction debris piled along west fence of Lots 63 and 64. 4. Blow sand accumulated along east boundary fence of Lots N, 25, and 52 through 65. 5. Central Retention basin constructed, with flatwork and landscaping. 6. The utility/manhole covers appear to have been adjusted in elevation to the proposed finish surface of the street. The concrete collars are in place; however, the pavers immediately around the concrete collars have not been replaced. Only observed in areas where road is covered with pavers. 7. Dry wells (4) have accumulated silt and trash and need maintenance. 8. Blow sand accumulated along west fence central. retention basin (east side of Lots 26 through 38. Flatwork in basin shows little signs of distress. Drainage into the basin from retaining walls at the east end of Lots 31 and 32 and the west end of Lots 45 and 46 needs to be addressed. 9. Exposed foundation along retention basin fence at west end of Lot 39 (former sales office site). Stockpiled soil and gravel. 10. Slight damage to curb and gutter — probably during removal of sales office trailer. Site Grading Based upon our review of the soil testing at the subject tract, performed through October 26, 2007, it is our opinion that the grading has been performed in general accordance with the project plans and above referenced geotechnical engineering reports. The subject building pad EARTH SYSTEMS SOUTHWEST May 31, 2011 3 File No.: 10109-06 Doc. No.: 11-05-752 areas were prepared and compacted as part of the overall mass grading that included the removal, and replacement of the upper 4 feet or more of soil as a compacted structural fill. Compaction was verified by field testing, as reported in the referenced documents. It is.our opinion that the subject pads were originally graded for the proposed use. However, subsequent undocumented fill was placed on some lots as discussed in other sections of this report. Since over one year has passed since the finish grading, we recommend some remedial effort prior to precise grading and building construction. The building pad area should be initially prepared by removing from the pad surface any organic growth, gravel, and undocumented fill or other material deposited on the pad since grading. The pad should then be scarified and moisture conditioned to near its optimum moisture content to a depth of at least one -foot below the current pad grade and rolled for compaction. If the pad grade is to be raised from its current elevation, non -expansive granular fills should be placed in maximum 8-inch lifts (loose) and compacted to at least 90 percent relative compaction (ASTM D 1557) near its optimum moisture content. If the pad is to be lowered in elevation, the depth of moisture conditioning may need to be increased. Additionally, depending upon the depth of cut (if any), additional over -excavation and compaction may be required. Areas to receive pools and spas will likely penetrate to depths of recompaction. Therefore, pools and spas should be supported by a minimum of 2 feet of soil compacted to at least 90% relative compaction (ASTM D 1557). Compaction should be verified by testing. For the lot paved with AC, the AC and aggregate base should be removed and disposed offsite. The compacted soil below the base should be prepared as above. Any landscaping and associated utilities and irrigation lines should be removed. Remaining exposed excavations should be backfilled and compacted. Structural (Post -tensioned) Slab Foundations Since 1996, the USGS has been investigating regional land subsidence in the Coachella Valley. The areas of subsidence coincide with localized ground -water -level declines due to overdraft. The USGS suggests that this documented subsidence is due to aquifer -system compaction. They go on to state that "the subsidence may also be related to tectonic activity in the valley." A review of the USGS data indicates that the Pasatiempo project site is at the southeastern margin of the La Quinta (Area 3) zone. While the reported areal subsidence is approximately 40 to 60 mm, the site is at the margin of the subsidence area, which can result in an area of greater tensional stress and possible surface manifestation of earth fissures. It is our opinion, and that of the City of La Quinta that, while predicting the location of surface ground ruptures as a result of fissuring is difficult to impossible, the potential hazards from fissuring and continued subsidence should be mitigated. While, to date, no evidence of fissuring has been noted on the project site, the potential of damage from fissuring exists and has been documented in this portion of the Coachella Valley. The foundations and structures should be designed to accommodate this possible settlement as a means of mitigating the hazard for life -safety. The recommendations that follow are based on "very low" expansion category soils. EARTH SYSTEMS SOUTHWEST May 31, 2011 4 File No.: 10109-06 Doc. No.: 1 l-05-752 Footing Design: In our professional opinion, structure foundations should be founded on a structural mat that is a flat -plate or waffled slab and uses either conventionally reinforced or post - tensioned tendons, designed to accommodate the estimated differential settlement of 2 inches in a 40-foot span (1:240 distortion ratio). Foundations should be bearing on a zone of properly prepared and compacted soils placed as recommended above under "Site Grading." Foundation design of widths, depths, and reinforcing steel are the responsibility of the Structural Engineer, considering the structural loading and the geotechnical parameters given in this report. A minimum footing depth of 12 inches below lowest adjacent grade should be maintained. A representative of ESSW should observe foundation excavations before placement of reinforcing steel or concrete. Loose soil or construction debris should be removed from footing excavations before placement of concrete. Allowable Bearing Pressure: Allowable soil bearing pressures are given below for foundations bearing on recompacted soils as described above. Allowable bearing pressures are net (weight of footing and soil surcharge may be neglected). ➢ 1500 psf for dead plus design live loads. No allowable increases are permitted. The allowable bearing value indicated is based on the anticipated maximum loads stated in the referenced report. If the anticipated loads exceed these values, the geotechnical engineer must reevaluate the allowable bearing values and the grading requirements. Modulus of Subgrade Reaction: Structural mat rigidity can be estimated by using a modulus of subgrade reaction (ksl) of 200 pci for the underlying subgrade. Static elastic settlements of foundations can be estimated using an effective modulus of subgrade reaction (kb) that is dependent on the effective width (b) of the foundation, where kb = ks1 [(b+l)/2b]2 and "b" equals the foundation width. The estimated elastic settlement is then equal to the effective bearing pressure (qe) in psi divided by kb. The effective bearing pressure (qe) may be computed as total design load divided by the effective bearing area. Frictional and Lateral Coefficients: Lateral loads may be resisted by soil friction on the base of foundations and by passive resistance of the soils acting on foundation walls. An allowable coefficient of friction of 0.35 of dead load may be used. An allowable passive equivalent fluid pressure of 250 pcf may also be used. These values include a factor of safety of 1.5. Passive resistance and frictional resistance may be used in combination if the friction coefficient is reduced to 0.23 of dead load forces. A one-third ('/3) increase in the passive pressure may be used when calculating resistance to wind or seismic loads. Lateral passive resistance is based on the assumption that any required backfill adjacent to foundations is properly compacted. Slabs -on -Grade Subarade: Concrete slabs -on -grade and flatwork should be supported by compacted soil placed in accordance with the Site Grading section of this report. EARTH SYSTEMS SOUTHWEST May 31, 2011 5 File No.: 10109-06 Doc. No.: 11-05-752 Vapor Retarder: In areas of moisture sensitive floor coverings, an appropriate vapor retarder should be installed to reduce moisture transmission from the subgrade soil to the slab. For these areas, an impermeable membrane (10-mil thickness) should underlie the floor slabs. The membrane should be covered with 2 inches of sand to help protect it .during construction and to aid in concrete curing. The sand should be lightly moistened just before placing the concrete. Low -slump concrete should be used to help reduce the potential for concrete shrinkage. The effectiveness of the membrane is dependent upon its quality, the method of overlapping, its protection during construction, and the successful sealing of the membrane around utility lines. The following minimum slab recommendations are intended to address geotechnical concerns such as potential variations of the subgrade and are not to be construed as superseding any structural design. The design engineer and/or project architect should ensure compliance with SB800 with regards to moisture and moisture vapor. Slab Thickness and Reinforcement: Slab thickness and reinforcement of slabs -on -grade are contingent on the recommendations of the structural engineer or architect and the expansion index of the supporting soil. Based upon our findings, a modulus of subgrade reaction of approximately 200 pounds per cubic inch can be used in concrete slab design for the expected very low expansion subgrade. Since this project will require engineered foundations, concrete slabs and flatwork thickness should be as specified by the project structural engineer. Concrete floor slabs may either be monolithically placed with the foundations or doweled after footing placement. The project architect or geotechnical engineer should continually observe all reinforcing steel in slabs during placement of concrete to check for proper location within the slab. Control Joints: Control joints (if specified) should be provided in all concrete slabs -on -grade at a maximum spacing of 36 times the slab thickness (12 feet maximum on -center, each way) as recommended by American Concrete Institute [ACI] guidelines and the project structural engineer. All joints, when used, should form approximately square patterns to reduce the potential for randomly oriented, contraction cracks. Contraction joints in the slabs should be tooled at the time of the pour or saw cut ('/4 of slab depth) within 8 hours of concrete placement. Construction (cold) joints should consist of thickened butt joints with '/2-inch dowels at 18 inches on center or a thickened keyed joint to resist vertical deflection at the joint. All construction joints in exterior flatwork should be sealed to reduce the potential of moisture or foreign material intrusion. These procedures will reduce the potential for randomly oriented cracks, but may not prevent them from occurring. Curing and Quality Control: The contractor should take precautions to reduce the potential for curling of slabs in this arid desert region using proper hatching, placement, and curing methods. Curing is highly affected by temperature, wind, and humidity. Quality control procedures may be used, including trial batch mix designs, batch plant inspection, and on -site special inspection and testing. Typically, for this type of construction and using 2,500-psi concrete, many of these quality control procedures are not required. EARTH SYSTEMS SOUTHWEST May 31, 2011 Mitigation of Soil Corrosivity on Concrete 6 File No.: 10109-06 Doc. No.: 11-05-752 Sulfate and other salts can attack the cement within concrete causing weakening of the cement matrix and eventual deterioration by raveling. This attack can be in the form of a physical attack or chemical attack whereby there may be a chemical reaction between the sulfate and the cement used in the concrete. According to ACI 318 as referenced by the 2007 California Building Code, if sulfate concentrations exceed 1000 ppm there will be special requirements. For this project, the results of those samples tested suggest a low sulfate ion concentration of 75 ppm. Normal concrete mixes may be used (ACI 318 Table 4.3.1). Electrical resistivity is a process whereby metal (ferrous) objects in direct contact with soil may be subject to attack by electrochemical corrosion. This typically pertains to buried metal pipes, valves, culverts, etc. made of ferrous metal. To avoid this type of corrosion or to slow the process, buried metal objects are generally protected with waterproof resistant barriers, i.e. epoxy corrosion inhibitors, asphalt coatings, cathodic protection, or encapsulating with densely consolidated concrete. Electrical resistivity testing of the soil suggests that the site soils may present a moderately corrosive potential for metal loss from electrochemical processes (1,240 ohm -cm). Chloride ions can cause corrosion of reinforcing steel. For this project, the results of those samples tested suggest a low chloride ion concentration of 148 ppm. ACI 318 is referenced by the California Building Code, [CBC] and provides commentary relative to the effects of chlorides present in the soil; from both internal and external sources. It is possible that long term saturation of foundations with chloride -rich water could allow the chloride access to the reinforcing steel. The soils encountered on this site consist of relatively free draining material. Therefore, if the site is adequately drained in accordance with sound engineering practice and the applicable codes, this should be a low threat. A minimum concrete cover of cast -in -place concrete should be in accordance with Section 7.7 of the 2007 edition of ACI 318. Additionally, the concrete should be thoroughly vibrated during placement. The information provided above should be considered preliminary. These values can potentially change based on several factors, such as importing soil from another job site and the quality of construction water used during grading and subsequent landscape irrigation. Earth Systems does not practice corrosion engineering. We recommend that a qualified corrosion engineer evaluate the corrosion potential on metal construction materials and concrete at the site to provide mitigation of corrosive effects, if further guidance is desired. Seismic Design Criteria This site is subject to strong ground shaking due to potential fault movements along the San Andreas and San Jacinto faults. The minimum seismic design should comply with the 2010 edition of the CBC. The CBC provisions are generally intended to protect human life safety and prevent structural collapse. They are not necessarily intended to prevent structural damage or preserve functionality after a large earthquake. Therefore, more stringent seismic design should be considered if a particular level of structural performance is desirable after a large earthquake. EARTH SYSTEMS SOUTHWEST May 31, 2011 7 File No.: 10109-06 Doc. No.: 11-05-752 That design should be based on a site- and project -specific seismicity analysis. The following are the 2010 CBC seismic design values: 2010 CBC (ASCE 7-05) Seismic Parameters Reference Seismic Category: D Table 1613.5.6 Site Class: D Table 1613.5.2 Latitude: 33.631111 N Longitude: 116.254056 W Maximum Considered Earthquake [MCE] Ground Motion Short Period Spectral Response SS: 1.50 g Figure 1613.5 1 second Spectral Response, SI: 0.60 g Figure 1613.5 Site Coefficient, Fa: 1.00 Table 1613.5.3(1) Site Coefficient, F,,: 1.50 Table 1613.5.3(2) Design Earthquake Ground Motion Short Period Spectral Response, SDs 1.00 g I second Spectral Response, SDI 0.60 g Closing Except as modified in this report, it is our opinion that the referenced documents are applicable to the proposed development.. We make no representation as to the accuracy of the dimensions, measurements, calculations, or any portion of the design. This report is issued with the understanding that the owner or the owner's representative has the responsibility to bring the information and recommendations contained herein to the attention of the architect and engineers for the project so that they are incorporated into the plans and specifications for the project. The owner or the owner's representative also has the responsibility to take the necessary steps to see that the general contractor and all subcontractors follow such recommendations. It is further understood that the owner or the owner's representative is responsible for submittal of this report to the appropriate governing agencies. As the Geotechnical Engineer of Record for this project, ESSW has striven to provide our services in accordance with generally accepted geotechnical engineering practices in this locality at this time. No warranty or guarantee is express or implied. This report was prepared for the exclusive use of the Client and the Client's authorized agents. ESSW should be provided the opportunity for a general review of final design and specifications in order that earthwork and foundation recommendations may be properly interpreted and implemented in the design and specifications. If ESSW is not accorded the privilege of making this recommended review, we can assume no responsibility for misinterpretation of our recommendations. This report is based on the assumption that an adequate program of client consultation, construction monitoring, and testing will be performed during the final design and construction phases to check compliance with these recommendations. Maintaining ESSW as the EARTH SYSTEMS SOUTHWEST May 31, 2011 8 File No.: 10109-06 Doc. No.: 11-05-752 geotechnical consultant from beginning to end of the project will provide continuity of services. . The geotechnical engineering firm providing tests and observations shall assume the responsibility of Geotechnical Engineer of Record. Should you have any questions concerning -our report, please give us a call and we will be pleased to assist you. Sincerely, EARTH SYSTEMS SOUT ST Reviewed by, QpOFESS/p _n4D5\ONAL GF j t�9 a. s y (Fy .Qfi— O t %S M WMNEY N • • a Joseph E. P9c*ney CE No. 1052 Q P No.8249 DP 341/71 pF CAL\FOB 9�FOrCAIif '�j9� CNfL o��1�Q. �F CANE Joseph E. McKinney Craig S. Hill GP 1052, PG 8249 CE 38234 SER/jem/csh/cen Distribution: 4/Alta Verde Construction, LLC. . 2/BD File Attachments: Figure 1 — Site Layout and Noted Features EARTH SYSTEMS SOUTHWEST May 31, 2011 9 File No,: 10109-06 Doc. No.: 11-05-752 REFERENCES City of La Quinta, 2010, Engineering Bulletin #09-03, Technical Memorandum with Respect to Collapsible Soils for Geotechnical Reports, Effective Date June 18, 2010, 9 p. Earth Systems Southwest, Geotechnical Engineering Report, Proposed 20-Acre Residential Development, 80-700 Avenue 58, West of Madison Street, La Quinta, California, File No. 10109-01, Doc No.: 05-05-771, dated May 18, 2005. Earth Systems Southwest, Infiltration Testing for Storm Water Retention Basin Design, Proposed Residential. Subdivision, 80-700 Avenue 58, La Quinta, California, File No. 10109- 04, Doc No.: 05-12-796, dated December 19, 2005. Earth Systems Southwest, Update to Geotechnical Engineering Report, Proposed Residential Development, 80-700 Avenue 58, La Quinta, California, File No.: 10109-04, Doc. No.: 06- 11-700, dated November 1, 2006. Earth Systems Southwest, Report of Testing and Observation Performed during Grading, Tract 34243; Pasatiempo, Avenue 58 West of Madison, La Quinta, California, File No.: 10109-05, Doc. No.: 07-04-857, dated May 1, 2007. Earth Systems Southwest, Soil Bearing Capacity for the Proposed Temporary Sales Office, Tract 34243 Pasatiempo, Avenue 58 West of Madison, La Quinta, California, File No.: 10109- 04, Doc. No.: 07-10-744, dated October 15, 2007. MDS Consulting, Tentative Tract Map No. 3XXXX, Portion of the S '/2, S %2, Sec. 21, T.6S, R.7E, S.B.M. file dated October 30, 2006. Sneed, M., and Brandt, J.T.,. 2007, Detection and Measurement of Land Subsidence Using Global Positioning System Surveying and Interferometric Synthetic Aperture Radar, Coachella Valley, California, 1996-2005: U.S. Geological Survey Scientific Investigations Report 2007-5251, 31 p. EARTH SYSTEMS SOUTHWEST 116°15'15 "W 11 , ;°15•:20"W 116°15'15"W 568900 569000 569100 569200 O O u, N n c� 7 O O N 04 N n 7 to a a M 116°15'25"W W16`l5'20"W 116°15'15 "W Figure 1 Site Layout and Noted Features ® Tract 34243 Pasatiempo LEGEND 3rrd North 80-700 Avenue 58, West of Madison `1F Feature Noted in Text. UTMZor•9 11, JVAD83 Datum La Quinta, Riverside County, California Site Boundary 29 o .. so, I® 150 zoo 29 Earth Systems Feet ~`� Southwest 05/31/2011 File No.: 10100-06 0 n u n 7 of h 0 M �I z of0 Bin #� S ' (�y of La Quinta s Building 8T Safety Division P.O. Box 1504, 78-495 Calee Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Per # 1' f rojtict Addre � .L r4WVJ. 1J Owner's Name: A?* tAtt"ar W/ A) 77- umber: V'C � �". ?Address: i ! Of 01 egal Description: ity, ST, Zip: 4&JC4 0 #'1t0(.c; 44- ntractor: ' tRoHlt11L l�- 1L'�'I'� lephone: f00 (0 - -Address: 14,44v MA Project Description: .SO (. 0_ lY s AMW -eity, ST, Zip: (Zt Ck" C.4.Cr 4 OS- fate Lic. # -HC•ty Lic. #; I // 0q SPA Arch., Engr., Designer: Address: (� City, ST, Zip: Telephone::.::<:•;>:..,;:;;:;:.;;:;:;:;;....;::;::,.;;::::•,:::::•,;s; <:::»:: ,>:.<.:<:ix.a»r :»:.:;:>: <•;.> r;:::>:::::<:>::. te Lic. # <::::;`:>s;rj r%>;::< ;,>::>;:;ar:<.;:>::< s ; Lameof Contact Person: to ���- Construction Type: Occupancy: , Project type (circle one): New Add n Alter Repair Demo Sq. Ft.: # Stories: # Units: ephone #,of Contact Person: Z'n- S 30 stimated Value of Project: 4'sO eteo APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted �/, Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cales. Called Contact Person Plan Check Balance Title 24 Cales. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees YIAksT60- fLA*-t Se6t '. AeA"^ZSD 1,6 - 0&.644su uKuu. F424.1 emism it is�t> - I • Coral. Mountain Master Plan Photovoltaic Permit & Plan Check Fees (from adopted schedule) Item Quantity - Permit fee, ea Plan Check fee, ea Total Fees Receptacle, switch-, etc. (first 20 =.1) 1 $ 23.83 $ ' 23.83 $ 47.66- (Used per Array, Inverter, Disconnect) . - Temporary power service ' .�0 $ 23.83 ., $ - 16.68 $ c - (Used per Sub -Panel) k Permit Issuance Fee -- t 1 `$ ,. 90.57, $ 90.57 Building Standards Fee, _ 0 $ 1.00 '$ ($1.00 per $25,000.00 Valuation)' ,- - ` Total Other Electrical Permit & Plan Check Fees _ $ 138.23 5.52 kWDC System Item Quantity .. Sunpower SPR-230NE-BLK-D 24 Power One PVI 5000-OUTD-US-A ' Total Square Feet @ 13:4SF Per Panel 3.68 kWDC System - Item Quantity E r i Sunpower SPR-230NE-BLK-D `,; `16 - Power One PVI 3.6-OUTD-US-A , Total Square Feet @ 13.4SF Per Panel 1.84 kWDC System ' Item Quantity _ Sunpower SPR-230NE-BLK-D • , 8 Power One PVI' 3.0-OUTD-US-A ' �1 Total Square Feet @-13.4SF Per Panel 107 1 � f .. r - .. _ we :", - • - - BUILDING ENERGY ANALYSIS REPORT PROJECT:" CORAL MOUNTAIN - PLAN C LA QUINTA, CA Project Designer: POON DESIGN INC 315'S. Beverly Drive, Suite 206 Beverly Hills, CA 90212 310-277-8855 Report Prepared. by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach,. CA 92660 94975216.12 Job Number: 62649 Date: 6/28/2013; CITY CAI' LA QUINTA �, aSAF,.TM DEPT. . The EnergyPro computer program has been used to perform the calculations summarized irS�this compliance rep A.Z5 s grogram h s appFoval and is authorized by the California Energy Commission for use with both the Residential and Non`residgnt�ial OjO Building Energy Efficidncy Standards. �hUc; t ION This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 5.1 by Energ Soft User Number: 8165 RunCode: 2013-06-28.T07:,19:23—ID:-62' 49L y TABLE OF CONTENTS Cover Page 1 Table of Contents. 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary 10 Form UTIL-1 R Utility Incentive Worksheet 13 C'I ► Y nF Q111 BUILDING & SAFE N% N DEPT. FOR CUN OVE® RUCTION DATE �- E EnergyPro 5.1 by EnergySoft Job Number: ID: 62649 ser Number: 165 Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/28/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/28/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name CORAL MOUNTAIN - PLAN C Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/28/2013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,849 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST . ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features --If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Wall Wood Framed R-21 3,173 New Wall Wood Framed R-19 149 Ext=R-4.0 New Roof Wood Framed Rafter R-38 2,849 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Right (S) 54.6 0.290 0.33 none none Roll -down Blind or Slats New Right (S) 340.0 0.540._r—, ,„0.32_none-( �-- none r,m,Roll-down Blind or,Slats New Front (W) f 32.6 'e 0 290 - 0.33' none none,eV. i' Roll -down Blind of Slats New Rear (E) yr'68 44 �I 0.290 0.33 none ,none Roll -down Blind or Slats New Rear (E) fk-0 ,<fF 0.320 0.28 none J none ,� Roll -down Blind or Slats , New 4• . J Jr l �.. a 'er fir Front (W),_ ,_ , 80.0 ' 0.540,,- 0.32 none , nonea Roll -down Blind or Slats �_' New Rear (E) 64.0 0.540 0.32 none none Roll -down Blind or Slats New HVAC SYSTEMS ' Qty. Heating Min. Eff Cooling Min.' Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value . Status 3.5T Carrier Ducted Ducted Conditioned 6.0 New 2.5TCarrier Ducted Ducted Conditioged61;. s 6.0 New 1.5T Carrier Ducted Ducted Conditioned�t T, L �6;0� New WATER HEATING L't�G SAF w IA Ot . Type Gallons Min. Eff Distribution�t-��� CEPT, /Status °fi; 1 Instant Gas 0 0.84 r Kitchen' hipe InrsGlVSfR" VJztjNew — al EnergyPro 5.1 by Energ Soft User Number: 8165 RunCode: 2013-06-28T07: 99.23 ID: 62649 Page 1 of 7 Reg: 213-N0047622B-000000000-0000 Registration Date/Time: 2013/06/27 13:08:22 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com.- 6/28/2013 3lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/28/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN C Building Type ®Single Family ❑ Addition Alone ❑ Multi Family. ❑ Existing+ Addition/Alteration I Date 6/28/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written ' justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. - Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. HERS REQUIRED .VERIFICATION Items in, this ssec{ion require field testing a d/or verificat o by a certified HERS Rater- Thelnspector, must receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System Bryant 315JAV048090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Bryant 315JA V036070 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 2.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HER field verification is required. The HVAC System 2.5T Carrier has Ducts, Plenums and the HVAC unit located tots°lly'v tithir�'C n i iongd pace% A p'ertiied'H' ERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. r j3Uji n h1f-_% o ~� e _._ N Te The HVAC System 2.5T Carrier includes credit for verified adequate airflow. A certified HERS rater Mu'sfldiagho; ti6al jL�esafure airflow of the HVAC System. i Opp p � / C The HVAC System 2.5T Carrier incorporates HERS verified Duct Leakage. —HERS field(v�rif[c�at�on�-an�d. ir�Ustic test' g is requr"ed to verify that. duct leakage meets the specified criteria. N 1 DATE RY EnerqvPro 5.1 by EnerqySoft User Number: 8165 RunCode: 2013-06-26264 Pa e 2 of 7 Reg: 213-N0047622B-000000000-0000 Registration Date/Time: 2013/06/27 13:08:22 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/28/2013 hectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/28/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN C Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/28/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach: The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED)VERIFICATION Items in this section'require field testing"and/or verification by a certified HERS Rater 7The'inspector•must receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System Bryant 315JAV036070(1) includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 1.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 1.5T Carrier has Ducts, Plenums and the HVAC. unit located totally within Conditioned space. A certified HERS'rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 1.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 1.5T Carrier incorporates HERS verified Duct Leakage. I4ERS field verification and diagnostic testing is required to verify that.duct leakage meets the specified criteria. DI11I�r& LA Qtj/ 7`/1 �`1 f r Ap�B/� DEPT. Div 'TRUCTIpN aA 1 EnerqyPro 5.1 by EnerqySoft User Number: 8165 RunCode: 2013-06-28T07:1913 --7D:.-6 Page 3 of 7 Reg: 213-N0047622B-000000000-0000 Registration Date/Time: 2013/06/27 13:08:22 HERS Provider: CalCERTS, Inc electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/28/2013 3lectronlcally Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/28/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone I Date CORAL MOUNTAIN - PLAN C ❑ Multi Family ❑ Existing+ Addition/Alteration 1612812013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV kBtu/ft2- r North East South West Space Heating 6.34 6.50 -0.16 6.83 -0.48 6.32 0.02 6.18 0.16 Space Cooling 77.90 47.29 30.60 45.27 32.62 46.02 31.88 47.14 30.76 Fans 15.56 17.17 -1.61 16.50 -0.94 16.75 -1.19 17.11 -1.55 Domestic Hot Water 12.80 • 9.12 3.69 9.12 3.69 9.12 3.69 9.12 . 3.69 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 o.00 _ o.00 0.00 Totals 112.60 80.08 32.53 77.72 34.88 78.20 34.40 79.55 33.06 Percent Better Than Standard: 28.9 % 31.0 % 30.6 % 29.4 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four Orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (tM _ 791 113 Fuel Available at Site: Natural Gas (N) 919 0 Raised Floor Area: 0 (E) 1,104 154 Slab on Grade Area: 0 (S) 1,170 395 Average Ceiling Height: 11.6 Roof 2,849 0 Fenestration Average U-Factor: 0.47 TOTAL: 662 Average SHGC: 0.32 Fenestration/CFA Ratio: 23.2 % REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply.with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author. Company GMEP Engineers, Campus Drive Gan i Zhou 6/28/2013 Address 4400 9y Name City/State/ ip Newport Beach, CA 92660 Phone 9497521612 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, apd-rec- gnizes that compliance using duct design, duct sealing, verification .of refrigerant charge, insulation installation gtfalita, . (�Pld'mg-envelope sealing require installer testing and certification and field verification by an approv d��Rater�P` (�UINTA I u! WING & DEPT, Designer or Owner (per Business & Professions Cod) APPROVED Company POON DESIGN INC FOR CONSTRUE® Address 315 S. Beverly Drive, Suite 206 Name. City/State/Zip Beverly Hills, CA 90212 Phone 310-277-88N5DATE Signed. Licens # Date d . � BY EneriqvPro 5.1 by EnerqySoft User Number 8165 RunCode: 2013-06-28T07:19:23 ID: 62649 Page 4 of 7 Reg: 213-N0047622B-000000000-0000 Registration Date/Time: 2013/06/27 13:08:22 HERS Provider: CalCERTS, Inc electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/28/2013 Electronically Signed at`Ca10ERTS.com by Russell Jones (Alta Verde Builders) 6/28/2013 0 CERTIFICATE OF COMPLIANCE: Residential - (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN C Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/28/2013 OPAQUE SURFACE DETAILS Surface Type Area U- FactorrR49 Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Exterior Frame Interior Frame Wall 663 0.069 0 90 New 4.3.1-A6 Conditioned Area Wall 298 0.069 180 90 New 4.3.1-A6 Conditioned Area Wall 70 0.0574.0 None 270 90 New , 4.3.1-A5 Conditioned Area Wall 79 0.0574.0 None 90 90 New 4.3.1-A5 Conditioned Area Roof 1,250 0.028 0 0 New 4.2.2-A19. Conditioned Area Wall 256 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 623 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 234 0.069 R-21 ' 180 90 New 4.3.1-A6 Conditioned Area Wall 282 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Roof 1,041 0.028 R-38 0 0 New 4.2.2-A 19 Conditioned Area Wall 248 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 243 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Wall 326 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Roof 558 0.028 R-38 0 0 New 4.2.2-A 19 Conditioned Area FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 8.2 0.290 NFRC 0.33 NFRC 180 New Andersen Double Pane Low E(1 Conditioned Area 2 Window 8.2 0.290 NFRC 0.33 NFRC 180 New Andersen Double Pane Low E(1 Conditioned Area 3 Window 8.2 0.290 NFRC 0.33 NFRC 180 New Andersen Double Pane Low E 1 Conditioned Area 4 Window 170.0 0.540 NFRC 0.32 NFRC 180 New Norwood 1000 Conditioned Area 5 - Window _ _� 170.0 0.540 NFRC 0.32 NFRC 180 New Norwood 1000 Conditioned Area 6 Window' 8.2 0.290 NFRC ,..J 0.33 NFRC _ 270 New-' Andersen Double Pane Low E(1 Conditioned Area 7 Window ' 8.2 0.290 NFRC 0.33 NFRC 270 New Andersen, Double Pane Low E(1 Conditioned Area 8 Window 8.2 : ,6.290 NFRC 0.33 NFRC ' .- 4 270 New :! Andersen'Double Pane,Low E(1 Conditioned Area 9 Window 8.2 10.290 NFRC 0.33 NFRC u 90 New- . Andersen Double Pane Low E(1 Conditioned Area., 10 Window 1 8.2 a 0.290 NFRC 0.33 NFRC ?90 "New Andersen Double Pane Low E(1 Conditioned Area - 11 Window.,- ' k 8.0 _, 0.290 NFRC -0.33 NFRC [.•' 90 New Andersen Double Pane Low E(1 Conditioned Area'rl 12 Window 22.0 0.320 NFRC 0.28 NFRC 90 New Andersen Double Pane Low E( Conditioned Area 13 Window 22.0 0.290 NFRC 0.33 NFRC 90 New Andersen Double Pane Low E(1 Conditioned Area 14 Window 22.0 . 0.290 NFRC 0.33 NFRC 180 New Andersen Double Pane Low E(1 Conditioned Area 15 Window 80.0 0.540 NFRC 0.32 NFRC 270 New Norwood 1000 Conditioned Area 16 Window 22.0 0.290 NFRC 0.33 NFRC 90 New Andersen Double Pane Low E(11 Conditioned Area (1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Ri ht Fin Hclt Wd Len Hclt LExt I RExt Dist Len Hclt Dist Len H t 1 Roll -down Blind or Slats 0.13 2 Roll -down Blind or Slats 0.13 3 Roll -down Blind or Slats 0.13 4 Roll -down Blind or Slats 0.13 5 Roll -down Blind or Slats 0.13 6 Roll -down Blind or Slats 0.13 7 Roll -down Blind or Slats 0.13 8 Roll -down Blind or Slats 0.13 9 Roll -down Blind or Slats 0.13 10 Roll -down Blind or Slats 0.13 P "" _� -•----. _ �_ 11 Roll -down Blind or Slats 0.13 e Y `_),`- p j 12 Roll -down Blind or Slats. 0.13 �LD>'P,q(� QQ A���" d I /'-► 13 Roll -down Blind or Slats 0.13 ` '"' -"If C I Y U 14 Roll -down Blind or Slats 0.13 ' OD C 15 Roll -down Blind or Slats 0.13�- 16 Roll -down Blind or Slats 0.13 DATE -_ BY EnergyPro 5.1 by EnergySbft User Number: 8165 RunCode: 2013-06-28T07:19:23 Page 5 of 7 Reg: 213-N0047622B-000000000-0000 Registration Date/Time: 2013/06/27 13:08:22 HERS Provider: CalCERTS, Inc -Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/28/2013 3lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/28/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R. Project Name CORAL MOUNTAIN - PLAN C Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 612812013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC'2 Azm Status Glazing Type Location/Comments 17 Window 64.0 0.540 NFRC 0.32 NFRC 90 New Norwood 1000 Conditioned Area 18 Window 8.0 0.290 NFRC 0.33 NFRC 180 New Andersen Double Pane Low E(1 Conditioned Area 19 Window 8.0 0.290 NFRC 0.33 NFRC 270 New Andersen Double Pane Low E(1 Conditioned Area -t4,. ,cif a;�•.d :. "� sl i .h '. ' i, i -.r'r, �, if (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 - SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID .Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin H t Wd Len H t LExt RExt Dist Len Hat Dist Len H t 17 Roll -down Blind or Slats 0.13 18 Roll -down Blind or Slats 0.13 19 Roll -down Blind or Slats 0.13 1_ )'11: LA ^ gym_ "--LING Z"1 V 1.4, /i7 ' '� O IC mot✓ DATE -� BY EnergyPro 5.1 by EnergySoft User Number 8165 RunCode: 2013-06-28T07:19:23 D" 6`2649 Page 6 of 7 Reg: 213-N0047622B-000000000-0000 Registration Date/Time: 2013/06/27 13:08:22 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/28/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/28/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN C Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date • , 6/28/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft Volume Year Built New Existinq Altered Removed 3.5T Carrier COMMON AREA 1,250 18,750 2.5T Carrier EAST WING 1,041 9,369 1.5T Carrier WEST WING 558 5,022 Totals 2,8491 0 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status. 3.5T Carrier 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 2.5T Carrier 1 Central Furnace 80%AFUE Split Air Conditioner. 15.5 SEER Setback New 1.5T Carrier .yy r 1 Central Furnace .80% AFUE Split Air Conditioner Y- . 16.0 SEER Setback New HVAC DISTRIBUTION:1 t System Name Heating Cooling Duct Location Duct, IL-1 R-Value Ducts"f,: Tested? Status 3.5T Carrier Ducted Ducted Conditioned 6.0 m New 2.5T Carrier w Ducted Ducted Conditioned 6.0 m New 1.5T Carrier Ducted, - Ducted Conditioned 6.0 M New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status RTG-95DVN 1 Instant Gas Kitchen Pipe Ins 199,900 0 0.84 n/a• n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC.H EATING SYSTEM PIPING Control Hot Water Piping Length ft N .o t6 Q tic' T C%�' �I . QF L ILI�JNG L ,Q ' 4, s-tern-NameAF�,'en .r=V �Ripe17' tb�. Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ;t❑ � �' 1VS Rr �..`' l N EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T07:19:23 ID: 62649 Reg: 213-N0041622B-000000000-0000 Registration Date/Time: 2013/06/27 13:08:22 HERS Provider: CalCERTS, Inc MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN C 6/28/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ACT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all hints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release . valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/h.r are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recir culating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lihes),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. .. M r / fi 1 �,r- 1 150 ' 3A: Insulation is protected from damage, includingthat due to sun,li ht ,m,,oisture, a ui merit mamtenance,�ano wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includd6-a-vapor retd6dantE iis�eUcIosed a tirely in conditioned space. (j �`�nr--N'-.,' A- 150 ' 4: Solar water-heatingsystems and/or collectors are certified b the Soldf Ratin ",arid Certif" *one 1 oratio . . i a If(-)N EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T07._19:23 -- I : 62649 Page 10 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN C 6/28/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CIVIC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 1 50m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ro rammed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150 k 7: All switching devices and controls -shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high •efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (FMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility -rooms are high efficacy and controlled by a manual -on occupant sensor. I i('�A-�-�� ,� s §150(k)9: Permanently installed lighting that is internal to cabinets shall use no TorE ttii n 20 watts of powerp®rr Iin� r�At t-of illuminated cabinet. LDI► G, R.�, ��r-C I �Y DEPT. Fp P,O O VEb ST%CTION DATE EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28TOT.49 23�� 70 -62aWI Page 11 of 16 I MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN C 1612812013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling -units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. err OF BUILDING & � QUIN7 A C '-) � FETY DEPT. FC),j Co ROVED ON DATs EnergyPro 5.1 by EnergySoft User Number. 8165 RunCode: 2013-06-28T07:19:23 ID: 62649 Page 12 of 16 I 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN C 6/28/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard % Better* Space Heating 6.34 6.50 -0.16 32.53 / 112.60 = 28.9 Space Cooling 77.90 47.29 30.60 Cooling Standard Heat Rejection 0.00 0.00 0.00 30.60 / 77.90 Indoor Fans 15.56 17.17 -1.61 Incentive Eligibility Yes No - Domestic Hot Water , 12.80 9.12 3.69 Owner Incentive (>=15%) 121 ❑ Pumps 0.00 0.00 0.00 NSHP Incentive '(>=30%) ❑ m Conditioned Floor Area = 2,849.0 ftz TOTALS:. 112.60 80.08 32.53 Number of Bedrooms = l 3 Energy Star V3 Target = 20 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard - 'Proposed Margin Facing North Peak Demand kW 9.8 F, 7.01 1 2.8 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas' Electricity Natural Gas Electricity ;Natural Gas kWh therms (kWh), therms kWh therms . Space Heating 0.00 112.99 0.00 115.90 0.00 -2.90 Space Cooling 10,084.67 0.00 5,883.91 0.00 4,200.76 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 2,197.90 0.00 2,327.81 0.00-129.90 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 12,282.57 358.33 8,211.72 290.23 4,070.86 68.10 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from ste 2) Rate from Step 3 Subtotal Electricity (kWh) 28.s %' 0.83 x a,o7o.8s Advanced Homes Program for $/kwh kWh new construction and are ElectricitykW 28..s % 144 x 2.8 $403 ( ) NOT GUARANTEED. Projects must meet all other program to $/kw kw Natural Gas 28.s % �' 3.30 X1 68.10 = $225 requirements qualify. Potential incentives are $/therm therm subject to program limitations 2013 Code Preparation = $o Pacific Gas and Electric Company NSHP Tier 11 = $o SOUTHERN CALIFORNIA' Total` liE D I S O N° Incentive 'rate is capped at the 45% level An Company - Zff LA �j !SAFETY DEPT. A Sempra Energy �Iiiity u calif ol,,'rn, "it1�VED The Gas • advance 0��. s Company - ' ' C By A �j Sempra Energy uuiny- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T07:19:23 /D: 62649 Page 13 of 16 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN C 6/28/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard % Better* Space Heating 6.34 6.83 -0.48 34.88 / 112.60 = 31.0 Space Cooling 77.90 45.27 32.62 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 32.62 Indoor Fans 15.56 16.50 -0.94 Incentive Eligibility Yes No Domestic Hot Water 12.80 9.12 3.69 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) m ❑ Conditioned Floor Area = 2,849.0 ft? TOTALS: 112.60 77.72 34.88 Number of Bedrooms = 3 Energy Star V3 Target = 20 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing East Peak Demand kW 9.81 6.61 1 3.2 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 112.99 0.00 121.66 0.00 -8.67 Space Cooling 10,084.67 6.00 5,637.79 0.00 4,446.87 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 2,197.90 0.00 2,248.25 0.00 -50.34 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 12,282.57 358.33 7,886.04 295.99 4,396.53 1 62.34 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive. Savings on this report are available from ste 2) Rate from Step 3 Subtotal only through the California Electricity (kWh) 31.0 % �� 0.89 x 4,396.53 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 31.0 % �> 155 X1 3.2 = $496 NOT GUARANTEED. Projects' must meet all other program $/kw kw Natural Gas 31.0 % �' 3.54 x 62.34 = $221 requirements to qualify'. Potential incentives are $/them, therm subject to program limitations. 2013 Code Preparation = $o pacific Gas and, I ¢ Electric Company NSHP Tier II = $o SOUTHERN CALIFORNIA TotalV1 ED. I S O N Incentive rate is capped at the 45% level -__ An I:DISUM1" 1N'I'IiR,�',A77U1411.° Company �E t, QUANTA 1\6AFETY A Sempra Energy utility' • D , ' '.� � EPT' EIS The Gas Company califarn a Co S STRRUC p adv.ancST A 1A Sernpra Energy utility` EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28TO7:19:23 /D: 62649 Page 14 of 16 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN C 6/28/2013 •1 ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 Margin Standard rE::34.40 % Better` ENERGY COMPONENT Standard Proposed Margin Space Heating 6.34 6.32 0.02 / 112.60 = 30.6 Space Cooling 77.90 46.02 31.88 Cooling Standard Heat Rejection 0.00 0.00 0.00 31.88 / 77.90 = 40.9 Indoor Fans 15.56 16.75 -1.19 Incentive Eligibility Yes No Domestic Hot Water 12.80 9.12 3.69 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) 110 ❑ Conditioned Floor Area = 2,849.0 ft2 TOTALS: 112.60 78.20 34.40 Number of Bedrooms = 3 Energy Star V3 Target = 20 % . • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing South Peak Demand kW 9.8 6.4 1 3.4 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 112.99 0.00 112.61 , 0.00 0.38 Space Cooling 10,084.67 0.00 5,884.90 0.00 4,199.77 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 2,197.90 0.00 2,327.78 0.00-129.88 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.001 0.00 0.00 1 0.00 0.00 TOTALS: 12,282.57 358.33 8,212.68 286.94 4,069.89 71.38 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available only through the California from step 2) Rate from Ste 3 Subtotal Electricity (kWh) 3o.s % �� 0.88 x1 4,069.89 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) x 3.4 = $520 NOT GUARANTEED. Projects must meet all other program requirements to qualify. $/kW kW Natural Gas 3o.s % 3.50 x 71.38 �� _ $250 , Potential incentives are $/them, therm subject to program limitations 2013 Code Preparation = $o Gas and VPacific -Z' Electric Company NSHP Tier n = $o SOLIMERN CALIFORNIA Total ED I S O N• Incentive rate is capped at the 45% level An EDISON IATERNATIONAI.^ Company Off Syr O '� QUI A A Sempra Energy utiGly` fD� &'-S gFETY DEFT, cd rn l Gas 1 :. ad � e TM Company V �J /ys A 1� Sempra Energy utiiity- DATE - By EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T07:19:23 ID: 6264 ° Page 15 of 16 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN C 6/28/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Margin Margin Standard % Better* Space Heating 6.34 6.18 0.16 33.06 / 112.60 Space Cooling 77.90 47.14 30.76 Cooling Standard Heat Rejection 0.00 0.00 0.00 30.76 / 77.90 = 39.5 Indoor Fans 15.56 17.11 -1.55 Incentive Eligibility Yes No Domestic Hot Water 12.80 9.12 3.69 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) ❑ 10 Conditioned Floor Area = 2,849.0 ft2 TOTALS: 112.60 79.55 33.06 Number of Bedrooms = 3 Energy Star V3 Target = 20 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing West Peak Demand kW 9.8 s.s 3.1 ENERGY COMPONENT Standard Proposed Margin Electricity Natural Gas Electricity Natural as Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 112.99 0.00 110.17 0.00 2.82 Space Cooling 10,084.67 0.00 6,007.55 0.00 4,077.12 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 2,197.90 0.00 2,367.28 0.00-169.37 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS:�7127282,57 358.33 8,374.82 284.50 3,907.75 73.82 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from step 2) Rate from Ste 3 Subtotal Electricity (kWh) 29.4 % �� 0.84 X1 3,907.75 = $3,283 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) X1 3.1 = $456 NOT GUARANTEED. Projects must meet all other program $/kW kW Natural Gas 2s.4 % �' X1 = requirements to qualify. 3.36 73.821 $248 Potential incentives are $/them, them, subject to program limitations 2013 Code Preparation = $o Pacific Gas and Electric Company NSHP Tier n = $o SOUTHERN CALIFORNIA Total ED I S O N• 1 Incentive rate is capped at the 45% level An EDISON IA'TE'R\IATIONAL• Company Sgi �I�E I QUINTA till G A�SempraEnerg?�ullmy` u &'SAFE ��EPr. cali�� b�� The V 1� T Gas Company adV p � A �Sempra Energy ulany- � 8Y EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T07:19:23 ID: 62649 - Page 16 of 16 BUILDING ENERGY ANALYSIS REPORT PROJECT: CORAL MOUNTAIN - PLAN D LA QUINTA, CA Project Designer: POON DESIGN INC 315 S. Beverly. Drive, Suite 206 Beverly Hills, CA 90212 310-277-8855 Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521612 Job Number: 62649 Date: QITY C�i� 6/27/2013 t BUILDIN(--1 L A QUINTA & SAFE F-10 ED C)N C01\1_PFcTc�� - The EnergyPro computer program has been used to perform the calculations summarized in this compliance-rePok)Oisiog4am has approval and is authorized by the California Energy Commission. for use with both the Residential 'and Nonresidential 2008 Building Energy Efficiency Standards. DATC- - This program developed by EnergySoft,.LLC _www.energysoft:eom.i3 I Energ Pro 5.1 by Energ Soft User Number: 8165 RunCode: 2013-06-27T09:34:23 ID: 62649 TABLE OF CONTENTS Cover Page 1 Table.of Contents 2 Form CF-1 R Certificate of. Compliance 3 Form MF-1 R Mandatory.Measures Summary 9 Form UTIL-1 R Utility Incentive Worksheet 12 Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/27/2013 'slectroriically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/27/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name CORAL MOUNTAIN - PLAN D Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/27/2013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,814 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF.-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5)' Status Wall Wood Framed R-21 2,042 New Roof Wood Framed Rafter R-38 2,814 New FENESTRATION U- Orientation Area(fe) Factor Exterior SHGC Overhang Sidefins Shades Status Front (N) 44.0 0.300 0.29 none none Roll -down Blind or Slats New Left (E) _.. ,70.5 0.290•--%- 0.29. -none-4 �--^ none .tom•_ a -..-Bug Screen New Right (W)'rr` 15.9 0.290 0.V' none none 3 Roll -down Blind or Slats New Right (W) ,t116.6 !0.290 0.29 ' none none Bug Screen •, fit New Frontr42.3 �`/� 0.290 0'29 none none :. Bug ScreenNew *? Left (E)NI, ` % i 22. 0 3 ' A0.300,,—' � --r 0. 29 - none* ; none_. �_ , Roll -down Blind or Slats'r R New Rear (S) 66.0 0.320 0.28 none none Roll -down Blind or Slats New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat . Status 1 Central Furnace 80% AFUE Split Air. Conditioner 15.5 SEER Setback New 1 : Central Furnace .80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value . Status 3.5T Carrier Ducted Ducted Conditioned 6.0 New 3.5T Carrier Ducted Ducted Conditioned-,----.-,6.0 New WATER HEATING BUILDING � TY D d T. SAFETY CENT• Is Qty. Type Gallons Min. Eff Distribrtt on;��,,-a, tatus 1 Instant Gas 0 0.84 Kitchen(Pige-lns� ', n Vr �^^% New ' DATE Energ Pro 5.1 by Energ Soft User Number: 8165 RunCode: 2013-06-27T09:34:23 ID: 62649 Page 1 of 6 Reg: 213-N0047626A-000000000-0000 Registration Date/Time: 2013/06/27 13:10:16 HERS Provider: CalCERTS, Inc 7lectronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/27/2013 electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/27/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN D Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 612712013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. . i HERS REQUIRED VERIFICATION Items in thisrs'�ction require field testing and/or verification by a certified HERS Rater: -The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System Bryant 315JAV048090 includes credit fora 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC. System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling "System Bryant 315JA V048090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verificatio0n�-is•rreequsi d. la 1 ➢� nE7 A A TheHVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totallp wi�thu LUItIoGd8space`iAlEertiafiq"r1HERS@rat6 r must visually verifythe installation of the HVAC unit and all Ducts and Plenums. IV SAFE I�rn�"i The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certified HERS��ty��n� �diiaag�noystiic�all.y Mdasare'airflo of the HVAC System. v !J E D The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS fi Id verifica rdn a di4§ osticV&I-- rI. required tl verify that. duct leakage meets the specified criteria. ATE BY --�_ EnerqyPro 5.1 by EnerqySoft User Number 8165 RunCode: 2013-06-27T09:34:23 1D: 6264 Page 2 of 6 Reg: 213-NO047626A-000000000-0000 Registration Date/Time: 2013/06/27 13:10:16 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/27/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/27/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone I Date CORAL MOUNTAIN - PLAN D ❑ Multi Family ❑ Existing+ Addition/Alteration . 1612712013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV kBtu/ft2- r North East South West Space Heating 3.63 2.17 1.47 2.07 1.56 2.00 1.63 2.20 1.44 Space Cooling 61.10 38.31 22.79 ' 37.29 23.80 38.70 22.40 37.79 23.31 Fans 12.19 13.92 -1.73 13.58 -1.39 14.06 -1.87 13.76 -1.57 Domestic Hot Water 12.96 9.23 3.73 9.23 3.73 9.23 3.73 9.23 3.73 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 89.89 63.62 26.26 62.18 27.71. 63.99 25.90 62.97 26.92 Percent Better Than Standard: 29.2 % 30.8 %'. 28.8 % 29.9 % BUILDING COMPLIES- HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four Orientations 'Ext. Walls/Roof Wall Area Area Number of Dwelling Units: ; 1.00 (N) 759 86 . Fuel Available at Site: Natural Gas" T (E) 682 93 Raised Floor Area: 0 - (S) 611 66 Slab on Grade Area: 0 (tM 367 133 Average Ceiling Height: 11.1 ; Roof 2,814 , 0 Fenestration Average U-Factor: 0.30 TOTAL: 377 Average SHGC: 0.29 Fenestration/CFA Ratio: 13.4 % REMARKS f, a ;•--•ry -• �.. - Ile f STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GMEP Engineers Address 4400 Campus Drive Name Gangyi Zhou 6727/2013 .City/State/Zip.City/State/Zip Newport Beach, CA 92660 Phone 9497521612 Signed Date The.individual with overall design responsibility hereby certifies that the proposed building design represented in this set. of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes.that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation qupfity-and-buildingeenveLope sealing require installer testing and certification and field verification by an approve tl HERS. ra''ter;. F LA QUIN�-A I BUILDING & SAFETY Designer or Owner (per Business &Professions Code DEPT. APPRO E Company POON DES/GN.INC 'APPROVED Address 315 S. Beverly Drive, Suite 206 Name ' FOR CONSTRUCT ION City/State/Zip Beverly Hills, CA 90212 Phone 310-277-8855 " Signed License # Date ..DATE EnerqvPro 5.1 by EnergySoft User Number 8165 RunCode: 2013-06-27T09:34:23 ID: 62649 Page 3 of 6 Reg: 213-N0047626A-000000000-0000 Registration Date/Time: 2013/06/27 13:10:16 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/27/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/27/2013 CERTIFICATE OF COMPLIANCE: Residential , (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN D Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/27/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Wall 328 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 245 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 234 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Roof 1,512 0.029 R-38 1 0 0 New 4.2.2-A18 Conditioned Area Wall 345 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 345 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 545 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Roof 1,302 0.029 R-38 0 0 New 4.2.2-A18 Conditioned Area FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 22.0 0.300 NFRC 0.29 NFRC 0 New Andersen Double Pane Low E(1 Conditioned Area 2 Window 22.0 0.300 NFRC 0.29 NFRC 0 New Andersen Double Pane Low E(1 Conditioned Area 3 Window 14.1 0.290 NFRC 0.29 NFRC 90 New . Plastpro Low E Conditioned Area 4 Window 14.1 0.290 NFRC 0.29 NFRC 90 New Plastpro Low E Conditioned Area 5 Window _ 4 14.1 0.290 NFRC 0.29 NFRC 90 New -_ Plastpro Low E _ Conditioned Area 6 Window' 5.3 0.290 1 NFRC ,. . ' 0.33 1 NFRC 270 New ! z Andersen Double Pane'Low E(2 Conditioned Area 7 Window ' 5.3 0.290 NFRC 0.33 NFRC 270 New Andersen Double Pane Low E(2 Conditioned Area 8 Window 5.3 ! 0.290 NFRC .0.33 NFRC . 4 270 New ! Andersen Double Pane Low E(2 Conditioned Area 9 Window 32.0 ► 0.290 NFRC 0.29 NFRC 1.0 270 New ; Plastpro Low E `, 5 Conditioned Area., � 10 Window W d28.2 $ 0.290 NFRC 0.29 NFRC 270 New Plastpro Low E I Conditioned Area 11 VVindoweC I =.,28.2 _.0.290 NFRC -0.29 NFRC - 270 New . t, Plastpro Low E Conditioned Area^+. 12 Window 28.2 0.290 NFRC 0.29 NFRC 270 New Plastpro Low E Conditioned Area 13 Window 28.2 0.290 NFRC • 0.29 NFRC 0 New Plastpro Low E Conditioned Area 14 Window 14.1 0.290 NFRC 0.29 NFRC 0 New Plastpro Low E Conditioned Area 15 Window 22.0 0.300 NFRC 0.29 NFRC 90 New Andersen Double Pane Low E(1 Conditioned Area 16 ..Window 28.2 0.290 NFRC, 0.29 NFRC 901 New Plastpro Low E Conditioned Area (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin Hat Wd Len H t LEA RExt Dist Len H t Dist Len H t 1 Roll -down Blind or Slats 0.13 2. Roll -down Blind or Slats 0.13 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6. Roll -down Blind or Slats 0.13 _ 7 Roll -down Blind or Slats 0.13 8 Roll -down Blind or Slats 0.13 j k�' l i `j,/' c i t- a ie 9 Bug Screen 0.76 i t?? n LJ1 ,)I 10 Bug Screen 0.76qA r_ " 11 Bug Screen 0.76 .A a lz) 6 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 it 15 Roll -down Blind or Slats 0.13 LATE 16 JBug Screen 0.76 L-- $y EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:34:23 ID: 62649 Pa e 4 of 6 Reg: 213-N0047626A-000000000-0000 Registration'Date/Time: 2013/06/27 13:10:16 HERS Provider: CalCERTS, Iric Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/27/2013 3lectroriically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/27/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN D Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/27/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 22.0 0.320 NFRC 0.28 NFRC 180 New Andersen Double Pane Low E(3 Conditioned Area 18 Window 22.0 0.320 NFRC 0.28 NFRC 180 New Andersen Double Pane Low E(3 Conditioned Area 19 Window 22.0 0.320 NFRC 0.28 NFRC 180 New Andersen Double Pane Low E Conditioned Area -� �f'. Al r �� a•' . '' } � _, 1 tr• � i, -'} % j� � �. -I d t ♦! ..1 4 . , 7 y (1) LI-Factor Type: 116-A = Default.Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hanq Left Fin Ri ht Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 17 Roll -down Blind or Slats 0.13 18 Roll -down Blind or Slats 0.13 19 Roll -down Blind or Slats 0.13 i � C nlhT.,.. ..� LZ U EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:34:23 ID: 62649 Pa e 5 of 6 Reg: 213-N0047626A-000000000-0000 Registration Date/Time: 2013/06/27 13:10:16 HERS Provider: CalCERTS, Inc electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/27/2013 3lectroriically Signed at Ca10ERTS.com by Russell Jones (Alta Verde Builders) 6/27/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN D Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/27/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area Volume Year Built New Existing Altered Removed 3.5T Carrier COMMON AREA 1,512 19,656 3.5T Carrier Bedrooms 1,302 11,718 t . Totals 2,814 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status ' 3.5T Carrier 1 Central Furnace 80% AFUE Split Air Conditioner - 15.5 SEER Setback New 3.5T Carrier 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New ��`^ar.'•T ..K �' y`ti.,.1 . --fw.- r:. _ i":.""'..`.—.� - ^'"r�"+. , -q• r ,s Fes, HVAC DISTRIBUTION , .l . X,•'/ ,� ..•�, ,r , System Name , -.. Heating, - Cooling ° ' Duct Location .- `Duct " = . :� R-Valuer Ducts" -;- Tested? Status 3.5T Carrier Ducted Ducted Conditioned 6.0 m New 3.5T Carrier Ducted Ducted Conditioned 6.0 m New El WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank . Cap. al Energy Factor or RE ' Standby Loss or Pilot Ext. Tank Insul. R- Value Status RTG-95DVN 1 Instant Gas Kitchen Pipe Ins 199,900 0 0.84 n/a n/a New r - MULTI -FAMILY WATER HEATING DETAILS -HV.D:RONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ff `LAQI -0 c c — Ui T y OF 'UILDING & SAFET( �PP �e , Pns- ster..Narne V E —� ' INN DEP Pipe LLn th Pipe iameter Insul. Thick. Qty. HP Plenum Outside Buried to �� I HUCTi n Ni 1❑ s V EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:34:23 ID: 62649 Page 6 of 6 Reg: 213-N0047626A-000000000-0000 Registration Date/Time: 2013/06/27 13:10:16' HERS Provider: CalCERTS, Inc MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN D 612712013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stri ed; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R.Form. * 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM El677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate•for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no cireater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and 'ping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. _ §150(j)2: Pipe insulation for steam hydronic heating systems or hot water . ysfem"s,J> 'S� si(fm—eetsfthe-requirements of Standards Table 123-A. ! At i�, � 114ciIiv /q ` „ 150 ' 3A: Insulation is protected from damage, includingthat due to sun0 ht, moi .0 fe a ui ment�mak eriaR9,1and, wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines ihcludes a vapor 'tar&arit�or"iss enclosed en irely in conditioned space. FOR 11I.cT ,,"-, 150 ' 4: Solar water-heatingsystems and/or collectors are certified b t e Solar Rating and Certification Cor oration. BY EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:34:23 ID: 62649 Page 9 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN D 612712013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method. of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only Burin off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain' a medium screw -base socket. 150 k 6: Li htind integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 150 k . 1 50k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programma le=control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, andrutili y oomms,`are. hig eh eh icacy-and=co _trolled by a manual -on occupant sensor. I „ „r r,I. — COf 1h\rrA I §l150a(k: Permanently installed lighting that is internal to cabinets. shall use no more th"an=20�watts of_p�owe�p.'err'li' ear foot of }tzp _06 U 60, CSTR ON . TE EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:34:23 'ID.- 62649 �_ Page 10 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN D 612712013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CITY OF LA QUINTA E'UILDI�IG e SAFETY DEPT. :—� Ft�f� `'Oi%S FRUCTp r✓,,%TE �_ BY EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:34:23 ID: 62649 Page 11 of 15 2 013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN D 6/27/2013 •1 ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Margin Margin Standard 71r % Better* Space Heating 3.63 2.17 1.47 26.26 / 89.89 = 29.2 Space Cooling 61.10 38.31 22.79 Cooling Standard Heat Rejection 0.00 0.00 0.00 22.79 / 61.10 = 37.3 Indoor Fans 12.19 13.92 -1.73 Incentive Eligibility Yes No Domestic Hot Water 12.96 9.23 3.73 Owner Incentive (>=15%) 121 ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ l� Conditioned Floor Area = 2,814.0 ft2 TOTALS: 89.89 63.62 26.26 Number of Bedrooms = 4 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing North Peak Demand kW 7.8 5.4 1 2.4 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 64.01 0.00 38.24 0.00 25.77 Space Cooling 7,620.66 0.00 4,798.38 0.00 2,822.28 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,659.60 0.00 1,862.95 0.00-203.35 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.001 0.00 TOTALS: 9,280.26 309.34 1 6,661.33 212.57 2-618.94 1 96.77 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from step 2) Rate from Ste 3 Electricity (kWh) x1 2,618.94 Subtotal Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) X1 2.4 = $350 NOT GUARANTEED. Projects must meet all other program $/kW kW Natural Gas 2s.2 °� �' X1 = requirements to qualify. 3.34 96.77 $323 Potential incentives are $/therm therm subject to program limitations 2013 Code Preparation = $o Pacific Gas and Electric Company NSHP Tier II= $o 0 1" SOUTHERN CA6FORNIA Total ED I S O N* Incentive rate is capped at the 45% level An EVISON 6%'7'ERNA7'10A'AI.8 Company C'Ty E �I• �f QUANTA Aiiiiii&O�� DEPT: \SAFETY ASempra Energy uumy* O VED y cali� ONSTRUCTION M The Gas adva >F Company :�Mes A Sempra Energy Remy EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:34:23 /D: 62649 Page 12 of 15 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN D 6/27/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard % Better* Space Heating 3.63 2.07 1.56 27.71 Space Cooling 61.10 37.29 23.80 Cooling Standard Heat Rejection 0.00 0.00 0.00 23.80 / 61.10 = 39.0 Indoor Fans 12.19 13.58 -1.39 Incentive Eligibility Yes No Domestic Hot Water 12.96 9.23 3.73 Owner Incentive (> 15%) 10 ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (> 30%) m ❑ Conditioned Floor Area = 2,814.0 ft2 TOTALS: 89.89 62.18 27.71 Number of Bedrooms = 4 Energy Star V3 Target = 15 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing East Peak Demand kW 7.s 5.2 1 2.6 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity . • Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 64.01 0.00 36.57 0.00 27.44 Space Cooling 7,620.66 0.00 4,702.61 0.00 2,918.05 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,659.60 0.00 1,829.10 0.00-169.50 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 9,280.26 309.34 6,531.71 210.90 2,748.55 98.44 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available only through the California from step 2) Rate from Ste 3 Subtotal Electricity (kWh) 30.8 % �' 0.88 X 2,748.55 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) X 2.6 = $400 NOT GUARANTEED. Projects must meet all other program requirements to qualify. $/kW kW Natural Gas 30.8 °ia 3.52 x 98.44 �� =$347 Potential incentives are $/them, therm subject to program limitations 2013 Code Preparation = $o Pacific Gas and Electric Company NSHP Tier 11 = $o SOUTHERN CALIFORNIA Total LIC E D I S O N• CITY OF � /fr ace t_er rat-f eaPeeat the 45% level BUILDING `S-A'1F UINTA An liUlSOa' 1;1'77iR.�'A'1'1U.1'Al.• Company & ETy DEPT. �EWr"OVED A �Sempra EnergymlGly` • ST8UCTION C0%l Y The Gas adv TM Campany A 5empra Energy utiiity- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:34:23 /D: 62649 Page 13 of 15 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN D 6/27/2013 • ANNUAL TDV ENERGY USE kBtu/sqft-yr PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard % Better* Space Heating 3.63 2.00 1.63 25.90 / 89.89 Space Cooling 61.10 38.70 22.40 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 22.40 / 61.10 = 36.7 Indoor Fans 12.19 14.06 -1.87 Incentive Eligibility Yes No Domestic Hot Water 12.96 9.23 3.73 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) ❑ m Conditioned Floor Area = 2,814.0 ftZ TOTALS: 89.89 63.99 25.90 Number of Bedrooms = 4 Energy Star V3 Target = 15 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing South Peak Demand kW 7.8 1 5.4 1 2.4 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 64.01 0.00 35.39 0.00 28.62 Space Cooling 7,620.66 0.00 4,910.40 0.00 2,710.26 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,659.60 0.00 1,901.24 0.00-241.64 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 1 0.00 1 71.00 Pumps 0.00 0.00 0.00 0.00 0.001 0.00 TOTALS: 9,280.26 309.34 6,811.64 209.72 2,468.62 99.62 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from step 2) Rate from Ste 3 Subtotal Electricity (kWh) 28.8 % ��' 0.83 X 2,468.62 = $2,049 Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) �' 144 X 2.41 = $346 NOT GUARANTEED. Projects must meet all other program requirements $/kw kw Natural Gas 28.8 % - 3.2s X 99.62 = $32s to qualify. Potential incentives are $ahem, therm subject to program limitations 2013 Code Preparation = $o Pacific Gas and Electric Company NSHP Tier II = $o \j SOUTHERN CALIFORNIA* Total ED I S O N entive rate is capped at the 45% level CITY OF LA An EDISO,\' INFf:HS'A'PIU.\'Al.• company +-L QUINTA SDGE �& SAFETY DEPT. � ROVED A Sempra Energy utility° calif C%ONSTRUCTjON n The Las advai h 7 Company A lA Sempra Energy utrty` EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:34:23 ID: 62649 Page 14 of 15 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN D 6/27/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW m' TITLE 24 ENERGY COMPONENT Standard Pronosed Mar in 7Margin Standard % Better* Space Heating 3.63 2.20 1.44 26.92 / 89.89 = 29.9 Space Cooling 61.10 37.79 23.31 Cooling Standard Heat Rejection 0.00 0.00 0.00 23.31 / 1 61.10 = 38.2 Indoor Fans 12.19 13.76 -1.57 Incentive Eligibility Yes No Domestic Hot Water 12.96 9.23 3.73 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) ❑ m Conditioned Floor Area = 2,814.0 fte TOTALS: 89.89 62.97 26.92 Number of Bedrooms = 4 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing West Peak Demand kW 7.8 1 5.4 2.4 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 64.01 0.00 38.76 0.00 25.25 Space Cooling 7,620.66 0.00 4,741.49 0.00 2,879.18 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,659.60 0.00 1,846.27 0.00-186.67 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.001 0.00 0.00 TOTALS: 9,280.26 309.34 6,587.76 213.09 1 2,692.51 1 96.25 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from step 2) Rate from Ste 3 Electricity (kWh) 29.9 % �� o.8s X1 Z692.511 Subtotal = $2,31s Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) X1 2.41 = $360 NOT GUARANTEED. Projects must meet all other program requirements to qualify. Natural Gas I 2s.s °� I �� $/kW kW 3.42 x ss.25 = $32s Potential incentives are $/therm therm subject to program limitations 2013 Code Preparation = $o Pacific Gas and Electric Company NSHP Tier II = $o rSOUIHERN GALIFORNIA Total ED I S O N* Incentive rate is capped at the 45% level An ROlSOA' 1N1'1iRVA7`10-VA1.• Company SvIg ; Y LA QUINTq DEPT. A *Sempra Energy utility' [SAFETY P �D � /'UCTl The Gas cali r adv LL Ome M Company A (�'Sempra Energy minty EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:34:23 /D: 62649 Page 15 of 15 BUILDING ENERGY ANALYSIS REPORT PROJECT: CORAL MOUNTAIN - PLAN J LA QUINTA, CA Project Designer: POON DESIGN INC 315 S. Beverly- Drive, Suite 206 Beverly Hills, CA 90212 310-277-8855 Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521612 Job Number: 62649 Date: CITY ®F LA BUILDING RUIN 1, 6/27/2013 DPP& SAFETypCPT. . FOB ������� CTION The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresitlential 008 Buildingsnergy Efficiency Standards. . This program developed by EnergySoft, LLC — www.energysoft.com. toff Energ Pro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:45:02 ID: 62649 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary 8 Form UTIL-1 R Utility. Incentive Worksheet .11 v 7lectronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/27/2013 'lectronically Signed at Ca10ERTS'com by Russell Jones (Alta Verde Builders) 6/27/2613 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name CORAL MOUNTAIN - PLAN J Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/27/2013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,668 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST " ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.. INSULATION Construction Type Area Special ` Cavit (ftz) Features see Part 2 of 5 Status Wall Wood Framed R-21 2,947 New Roof Wood Framed Rafter R-38 2,668 New FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC • Overhang Sidefins Shades Status Right (N) 44.0 0.300 0.29 none none Roll -down Blind or Slats New Right (N) 8.0 0.290 _0.33_:none , ---,<none p.,; ,_-,..Roll-down,Blind or Slats New Right (N) r�f� 128.0 ' 0.'546 1, 0.32 noneV none k Bug Screen : New Left (S)y16.0 ,� .� 0.290 0.33 none °'n`one jl Roll -down Blind or Slats. New Front (E) ,/V 200.0 f r 0.540 0.32 nonenone }f _ ,Bug Screen `! •,Fi' rNeiv r Rear.(W).- ` ' ' ��`28.Or , t0.280.� r �0.28 none­.J none, 1 ` 7r Z - " ,. Roll -down Blind or,Slats 1 New Rear (W) 24.0 - 0.290 0.33 none none Roll -down Blind or Slats New Front (E) 22.0 0.320 0.28 none none Roll -down Blind or Slats New Left (S) 44.0 0.320 0.28 none none Roll -down Blind or Slats New HVAC SYSTEMS Ot . , Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 1 Central. Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status 3.5T Carrier Ducted Ducted Conditioned 6.0 New 3.5T Carrier Ducted Ducted Conditioned 6.0 New WATER HEATING I Y 0F LA Ot T e Gallons Min. Eff Disirrli�irtion S QUIIVTq AF r=,,, S tatus 1 Instant Gas 0 0.84 Kitchen Pip'e,lns Pnva New 1 t'oN CONSTRU Tl ! U"ATE ------- BY . Energ Pro 5.1 by Energ Soft User Number. 8165 . RunCode: 2013-06-27T09:45-62'-"--ti9.6.264 1 Page 1 of 5 Reg: 213-N0047627B-000000000-0000 Registration'Date/Time: 2013/06/27 13:10:36 HERS Provider: CalCERTS, Inc c Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/27/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/27/2013 PERFORMANCE CERTIFICATE: Residential . (Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN J Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/27/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. V , r HERS REQUIRED VERIFICATiIONj. Items in this,section require field testing and/or verification by a certified HERS Rater"• -The inspector -must receive a . completed CF-4R form for each of the measures listed below for final to be given. The Cooling System Bryant 315JAV048090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 3.5T Carrier includes credit for verified adequate. airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Bryant 315JA V048090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located toi'all i ih Con°it' fed spade. A ce'rtifled-HE S rter must visually verify the.installation of the HVAC unit and all Ducts and Plenums. f3l�ILQlf�tr, R. cn 1 � �-. The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A ce ified HERS rater must dib0hdsticallylrrie`as ,e, airflow of the HVAC' System. I A f-J i R O ` !,/I= The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HER S,Jfield verif(cdtiPCa , Jiagroy tU�te �ti/r- require • to verify that duct leakage meets the specified criteria. 81 I tV IDATE BY EnerqyPro 5.1 by EnerqySoft User Number 8165 RunCode: 2013-06-27T09:4r-02-- mil®-626.49 ' Pa e 2 of 5 Reg: 213-N0047627B-000000000-0000 Registration Date/Time: 2013/06/27 13:10:36 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/27/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/27/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date CORAL MOUNTAIN - PLAN J ❑ Multi Family ❑ Existing+ Addition/Alteration 1612712013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV kBtu/ft2- r North East South West Space Heating 5.78 5.24 0.53 4.73 1.05 4.30 1.48 4.69 1.09 Space Cooling 75.50 46.63 28.87 46.15 29.34 49.56 25.93 50.13 25.36 Fans 15.04 17.02 -1.98 16.87 -1.83 18.05 -3.01 18.21 -3.17 Domestic Hot Water 13.67 9.73 3.94 9.73 3.94 9.73 3.94 9.73 3.94 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 109.99 78.63 31.36 77.49 '32.50 81.65 28.34 82.77 27.22 Percent Better Than Standard: 28.5 % 29.5 % 25.8 % 24.7 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 = (E) 727 222 Fuel Available at Site: Natural Gas (S) '739 60 Raised Floor Area: 0 (tM, 466 52 Slab on Grade Area: 0. (N) 1,529 180 Average Ceiling Height:, 11.7 Roof 2,668 0 Fenestration Average U-Factor: 0.45 - TOTAL: 514 r Average SHGC: 0.31 Fenestration/CFA Ratio: 19.3 REMARKS - STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the -documentation is accurate and complete. Documentation Author Company GMEP Engineers AddName 9yress 4400 Campus Drive Gan i Zhou 6/27/2013 City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone 9497521612 Signed. Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and reco Qizes th'at-corrrp+iaeee-ws mgadu.esign, duct sealing, verification of refrigerant charge, insulation installation qualit)F-,Wbuiidsr'g env�ldpeLealVq- q ire installer testing and certification and field verification by an approved HER Lraterr'ING & SAFETY DEPT. Designer or Owner (per Business & Professions Code) APPROVED Company POON DESIGN INC FOR CONSTRUCTION Address 315 S. Beverly Drive, Suite 206. Name City/State/Zip Beverly Hills, CA 90212 Phone 310-277-8855 DATE Signed- BY License # , Date Ener Pro 5.1 by Ener�qySoft User Number: 8165 RunCode: 2013-06-27T09:45:02 ID: 62649 Page 3 of 5 Reg: 213-N0047627B-000000000-0000 Registration Date/Time: 2013/06/27 13:10:36 HERS Provider: Ca10ERTS,_Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.COin - 6/27/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/27/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN J Building Type m Single Family ❑ Addition Alone ❑ Multi Family " ❑ Existing+ Addition/Alteration Date 6/27/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix • 4 Location/Comments Cavity Exterior Frame Interior Frame Wall 765 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 82 0.069 R-21 180 90 New 4.3.1-A6, Conditioned Area Wall 163 0.069 R-21 90 - 90 New 4.3.1-A6 Conditioned Area Wall 414 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Roof 1,452 0.028 R-38 01 0 New 4.2.2-A19 Conditioned Area Wall 585 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 342 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 597 0.069 R-21 180 90 New • 4.3.1-A6 Conditioned Area Roof 1,216 0.028 R-38 0 0 New 4.2.2-A19 Conditioned Area FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm . Status Glazing Type Location/Comments 1 Window' '22.0 0.300 NFRC 0.29 NFRC, 0 New Andersen Double Pane Low E(1 Conditioned Area 2 Window 22.0 0.300 NFRC 0.29 NFRC. 0 New Andersen Double Pane Low E(1 Conditioned Area 3 Window' 8.0 0.290 NFRC 0.33 NFRC. 0 New Andersen Double Pane Low E Conditioned Area 4 Window 64.0 0.540 NFRC 0.32 NFRC :. 0 New Fleetwood 1000 Conditioned Area 5 Window, v- 8.0 0.290 NFRC 0.33 NFRC 1801 New . -___ Andersen Double Pane Low E(2 Conditioned Area 6 Window 200.0 0.540 NFRC , rr` 0.32 NFRC %90 New * Fleetwood.1000 r k Conditioned Area 7 Window 128.0 0.280 NFRC 0.28 NFRC 270 New Andersen, Double Pane Low E(4 Conditioned Area 8 Window 8.0 ' "0.290 NFRC 0.33 NFRC - . -4 270 New, ,'' Andersen'Double Pane Low E(2 Conditioned Area 9 Window 8.0 10.290 NFRC 0.33 NFRC,, 7 270 New , ; Andersen Double Pane Low E(2 Conditioned Area,. 10 Window 8.0 f 0.290 NFRC 0.33 NFRC ,,270 'New .1 Andersen Double Pane Low E(2 Conditioned Area - 11 Window.0 a k 64.0 _• 0.540 NFRC .- 6.32 NFRC 0 New Fleetwood 1000 t -; 5 - - . Conditioned Area'!-t 12 Window 22.0 0.320 NFRC 0.28 NFRC 90 New Andersen Double Pane Low E( Conditioned Area 13 Window 8.0 0.290 NFRC 0.33 NFRC 1.80 New Andersen Double Pane Low E(2 Conditioned Area 14 Window 22.0 0.320 NFRC 0.28 NFRC 180 New Andersen Double Pane Low E( Conditioned Area 15 Window 22.0 0.320 NFRC 0.28 NFRC 180 New Andersen Double Pane Low EQ Conditioned Area (1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value . EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hanq Left Fin Ri ht Fin . H t FWd Len H t LExt REA Dist Len H t Dist Len H t 1 Roll -down Blind or Slats 0.13 2 Roll -down Blind or Slats 0.13 3 Roll -down Blind or Slats 0.13 4 Bug Screen 0.76 5 Roll -down Blind or Slats 0.13 6 Bug Screen 0.76 7 Roll -down Blind or Slats 0.13 8 Roll -down Blind or Slats 0.13 9 Roll -down Blind or Slats 0.13 10 Roll -down Blind or Slats 0.13 np 1A rNo 11 'Bug Screen 0.76 l J I 12 Roll -down Blind or Slats 0.13 f& 8AFE 13 Roll -down Blind or Slats 0.13 r- 14 Roll -down Blind or Slats 0.13 ' a V � 15 Roll -down Blind or Slats 0.13 I ' j0 LDATE.____7 BY EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:45:02 ID: 62649 Page 4 of 5 Reg: 213-N0041627B-000000000-0000 Registration Date/Time:'2013/06/27 13:10:36 HERS Provider: CalCERTS, Inc -Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/27/2013 3lectronically Signed at Ca10ERTS.com by Russell Jones (Alta Verde Builders) 6/27/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN J Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/27/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ff Volume Year Built New I Existing Altered Removed 3.5T Carrier COMMON AREA 1,452 20,328 3.5T Carrier Bedrooms 1,216 10,944 Totals 2,668 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Typ e Status 3.5T Carrier 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 3.5T Carrier 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION •,J! , k tJ' ,r't - k.... r- �- S stem Name , i ., -r- .. HeatingCoolingDuct .` r^ .. +.. .yam_-: s._ Location ':. Duct".,, R-Value U .Ducts,7r- Tested? Status 3.5T Carrier Ducted Ducted Conditioned . 6.0 fa New 3.5T Carrier Ducted Ducted Conditioned 6.0 m New WATER HEATING SYSTEMS ` S stem Name Qty. -Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or:RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status RTG-95DVN 1 Instant. Gas Kitchen Pipe Ins 199,900 0 0.84 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control. Hot Water Piping Length .0 Q — CI � BDILD�i-WO i �'" tr System Name 1 F LA &SAFETY �f?�p�e Lien D QU�I � V DEFT t R.Pi JRra_me�er A . Ins I. , Thi k. Qty. HP Plenum Outside Buried ❑ 1 r°Uri UUNSTRUCTIOM ❑ 1 ❑ ? D TP ------- EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:45:02 1D: 62649 Page 5 of 5 Reg: 213-N0047627B-000000000-0000 Registration: Date/Time: 2013/06/27 13:10:36 HERS Provider: CalCERTS, Inc MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN J 612712013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (`) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leaka e. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent 1-1-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no cireater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the'exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems; and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water system >1j5'V9'�� st iZfeGir�entsbfStanda�ds Table 123-A. Y-AI rt 150 ' 3A: Insulation is protected from damage, includingthat due to sunli ht, mo sture, a ui men main a ance an�wind: §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor etard4n gr�K e,,ncl6sed er irely in conditioned space. QR r ICTRI 112TIC 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar I latingand Certification Corporation DATE BY J EnergyPro 5.1 by EnergySoft User Number: 8165-RunCode: 2013-06-27T09:45:02 ID: 62649 Page 8 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN J 612712013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support plafforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor poolsprs as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ro rammed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Liqhting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programs abte�mtwl-system,-and-all-permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and util'ty r`oaJ Tffe Fg��ffica qy(ana c",ontrollei�by a manual -on occupant sensor. .. rrT r,r §15*)9: Permanently installed. lighting that is internal to cabinets shall use no mo a kt i • afts�ofrpowe"r per linear foot of illuminated cabinet. P � �? n" ®...� W Y Y c �M FOR CONSTRUCTION DATE BY EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:45:02 ID: 62649 Page 9 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN J 612712013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119: EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be. listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals. when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including. lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances,balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with. Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features,. or other location subject to Article 680 of the California Electric Code need not be hi h efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130 d . . §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles. per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more '. dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to com I with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:45:02 ID: 62649 Page 10 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN J 612712013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard % Better* Space Heating 5.78 5.24 0.53 31.36 Space Cooling 75.50 46.63 28.87 Cooling Standard Heat Rejection 0.00 0.00 0.00 28.87 / 75.50 = 38.2 Indoor Fans 15.04 17.02 -1.98 Incentive Eligibility Yes No Domestic Hot Water 13.67 9.73 3.94 Owner Incentive (-15%) 121 ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) ❑ 121 Conditioned Floor Area = 2,668.0 ftz TOTALS: 109.99 78.63 31.36 Number of Bedrooms = 1 4 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing North Peak Demand kW 8.96.4 1 2.5 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 96.39 . 0.00 87.58 0.00 8.81 Space Cooling 9,134.25 0.00 5,477.26 0.00 3,656.99 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,981.90 0.00 2,156.84 0.00-174.94 0.00 Domestic Hot Water 0.00 245.33 . 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 �63410 0.00 0.00 0.00 TOTALS: 11,11615 341.73 261.92 3.482.05 79.81 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from step 2) Rate from Ste 3 Subtotal Electricity (kWh) 2s.5 % �� o.s2 X 3,482.05 Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) 28.5 % �� 142 X 2.5 = $355 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 28.5 % �' X = requirements to qualify. 3.26 79.81 $260 Potential incentives are $/them, them, subject to program limitations 2013 Code Preparation = $o Pacific Gas and . Electric Company NSHP II Tier = $o 0 WilSOUTHERN CALIFORNIA Total ED I S O N• Incentive rate is capped at the 45% level .4a EDISON 11V77iRA'A770NA1.- company OF LA QU I SQGE .ITY 1 YTA U! SAFETY DEPT. �Sempra Energy a& i'A O`�/EDy` uGla ffn CONSTRUCTIONcali 1adV The Gas TM Company A �j�Sempra Energy minty- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:45:02 /D: 62649 Page 11 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN J 612712013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard rl % Better* Space Heating 5.78 4.73 1.05 32.50 / 109.99 = 29.5 Space Cooling 75.50 46.15 29.34 Cooling Standard Heat Rejection 0.00 0.00 0.00 29.34 / 75.50 = 38.9 Indoor Fans 15.04 16.87 -1.83 Incentive Eligibility Yes No Domestic Hot Water 13.67 9.73 3.94 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) ❑ m Conditioned Floor Area = 2,668.0 ftz TOTALS: 109.99 77.49 32.50 Number of Bedrooms = 4 Energy Star V3 Target = 15 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing East Peak Demand kW 8.9 1 L5.8 1 3.1 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 96.39 0.00 78.89 . 0.00 17.50 Space Cooling 9,134.25 0.00 5,671.37 0.00 3,462.88 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,981.90 0.00 2,221.56 0.00-239.66 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.001 0.00 0.00 0.001 0.00 TOTALS: 11,116.15 341.73 7,892.93 253.22 1 1 3,223.22 88.50 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from step 2) Rate from Ste 3 Subtotal Electricity (kWh) 29.5 % ' 0.85 x 3,223.221 = $2,740 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 2s.5 % � 148 X1 3, 11 = $459 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 2s.5 % �' X1 = requirements to qualify. 3.37 88.50 $298 Potential incentives are $/them, therm subject to program limitations 2013 Code Preparation = $o Pacific Gas and " Electric Company NSHP Tier II = $o SoutHIRN CALIFORNIA Total ED I S O N' Ince tive rate is -capped at the 45% level CI OF LAUISJ `� I A. An I'PlSO.\' ItiTIiRCATlOSAI.• Company SDG'` t�_">> ' '`,F4TY DEPT. MEOW A Sempra Energy utitily' caliT AW t tyi�d�iS i RUCTION The Gas advali nia Company #4J A Sem pra Energy utitlty- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:45:02 /D: 62649 Page 12 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN J 6/27/2013 • ANNUAL TDV ENERGY USE kl3tu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard % Better* Space Heating 5.78 4.30 1.48 28.34 / 109.99 Space Cooling 75.50 49.56 25.93 Cooling Standard Heat Rejection 0.00 0.00 0.00 25.93 / 75.50 = 34.4 Indoor Fans 15.04 18.05 -3.01 Incentive Eligibility Yes No Domestic Hot Water 13.67 9.73 3.94 Owner Incentive (> 15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (> 30%) ❑ m Conditioned Floor Area = 2,668.0 ftz TOTALS: 109.99 81.65 28.34 Number of Bedrooms = 4 Energy Star V3 Target = 15 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing South Peak Demand kW 8.96.1 1 2.8 ENERGY COMPONENT Standard Proposed Margin Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 96.39 0.00 71.77 0.00 24.62 Space Cooling 9,134.25 0.00 6,231.02 0.00 2,903.23 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,981.90 0.00 2,416.23 0.00-434.33 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 1 0.001 1 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 11,116.15 341.73 8,647.25 246.10 1 2.468.90 95.62 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from step 2) Rate from Ste 3 Subtotal Electricity (kWh) 25.8 % �> 0.74 X1 2,468.90 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) X1 2.8 = $361 NOT GUARANTEED. Projects must meet all other program requirements to qualify. $/kW kW Natural Gas 25.8 % 2.95 x 95.62 �� $282 Potential incentives are $/therm therm subject to program limitations 2013 Code Preparation = $o Pacific Gas and .q Electric Company NSHP Tier 11 = $o SOUTHERN CALIFORNIA Total ED I S O N* Incentive rate is capped at the 45% level An 1:.01SON 1,N7'ERVA770NAL- Company I+ UTY OFLA ^ U I NTA SGE-' - G,& SAFETY DEPT. A *Sempra Energy .'� �'"VEt...1Caff6 molly` l� 11 ll U ri COSTRUCTION The Gas aTM dvanced-h6mes- Company A Sempra Energy uGrry- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:45:02 /D: 62649 Page 13 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN J 612712013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard % Better* 7 Space Heating 5.78 4.69 1.09 27.22 / 109.99 = 24.7 Space Cooling 75.50 50.13 25.36 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 25.36 / 75.50 = 33.6 Indoor Fans 15.04 18.21 -3.17 Incentive Eligibility Yes No Domestic Hot Water 13.67 9.73 3.94 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 2,668.0 ftz TOTALS: 109.99 82.77 27.22 Number of Bedrooms = 4 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE rAverage 2pm - 5pm Standard Pro osed Facing West k Demand kW 8s 6.7 7i2 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 96.39 0.00 78.28 0.00 18.11 Space Cooling 9,134.25 0.00 6,035.34 0.00 3,098.91 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,981.90 0.00 2,347.37 0.00-365.46 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0:00 0.00 0.00 0.00 TOTALS: 11,116.15 341.73 1 8,382.71. 252.61 2,733.44 89.12 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from ste 2) Rate from Ste 3 Subtotal Electricity (kWh) 24.70 ' 0.71 X 2,733.44 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) X1 2.1 = $260 NOT GUARANTEED. Projects must meet all other program requirements to qualify. /kW kW Natural Gas 24.7 % �' 2.83 X1 89.12 = $252 Potential incentives are $/them, them, subject to program limitations 2013 Code Preparation = $o Pacific Gas and . Electric Company NSHP Tier n = $o SOUTHERN CALIFORNIA Total ED I S O N* Incentive rate is capped at the 45% level An hDISUA" fi1'YY>RNA77U.\'AI,^ Company SD AS(:T11praEllergyutifity* o ��, LA QUI cco, �l��U b�NTA `SAFETY DEPT. The Gas advan ,� , �T M Company A SempraEnergy many- i -rrPy EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T09:45"02' ` ID: 62649 Pa a 14 71 BUILDING ENERGY ANALYSIS REPORT PROJECT: CORAL MOUNTAIN - PLAN Z LA QUINTA, CA Project Designer: POON DESIGN INC 315 S. Beverly Drive, Suite 206 Beverly Hills, CA 90212 310-277-8855 Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521612 ' Job Number: 62649 Date: 6/27/2013 CITY OF LA QUANTA. BUILDING & SAFETY DEPT. APPROVED The EnergyPro computer program has been used to perform the calculations summarized in his complj�nce,repot i Thiscp'og,am hasiapproval and is authorized by the California Energy Commission for use with both the Residential and Nonlesidential-2008rBuildin�g' Energy-Effiaency Standards: This program developed by EnergySoft, LLC — www.energysoft.com. I DATE RY Energ Pro 5.1 by Energ Soft User Number: 8165 RunCode: 2013-06-27T10:0125 ID_ 62649 I' TABLE OF CONTENTS i Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary 8 Form UTIL-.1 R Utility Incentive Worksheet 11 CITY OF LA QUINTA 3?.�I�Dd;C &SAFETY DEPT. ROVED FOR CONSTRUCTION { EnergyPro 5.1 by EnergySoft . Job Number: ID: 62649 User Number: 8165 ^lectronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/27/2013 'lectronically Sinned at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/27/2011 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name CORAL MOUNTAIN - PLAN Z Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family 0 Existing+ Addition/Alteration Date 1612712013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,708 I Addition - 1 n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes 0 No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. - INSULATION Construction Type Area Special Cavity (112) Features see Part 2 of 5) Status Wall Wood Framed R-21 1,813 New Roof Wood Framed Rafter R-38 2,708 New FENESTRATION Orientation Area(fl U- Factor SHGC Overhang Sidefins Exterior Shades Status Front (E) 357.2 0.560 0.32 none none Bug Screen New Front(E) ��� ;35.3 -0.380y;. �,.0.34 _none-, .-_:none r., . Roll -down Blind or Slats New Front (E)"";' 28.2 f 0.290 V0.29 none i3 none 1 Bug Screen L. New Left (S)' OZ44.0 0.290 0.33 none -ro' e Roll -down Blind or Slats New .' Right (N)� ' r44.0 ii { {' 0.310 0{31 none jr _ none J Roll -down Blind or Slats ' ` , New ` Rear (t q., t+ ` �33.9; ' '0.290_A. 6.33 -non'e none,, Roll -down Blind or Slats t/ 1 New Rear 13.4 0.280 0.28 none none Roll -down Blind or Slats New Left (S) 44.0 0.310 0.31 none none Roll -down Blind or Slats New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION' Location. Heatin 3.5T Carrier Ducted 3.5T Carrier -Ducted WATER HEATING Ot . Type 1 Instant Gas Coolin Ducted Ducted Gallons Min. Eff Disti 0 0.84 Kitche Duct Location Conditioned Conditioned f- DX UUIIN I A BUILDING & SAFETY ibutio, PPROVED Sta Pipe IrFOR CONSTRUCTION New DATE BY Duct R-Value Status 6.0 New is Reg: 213-N0047629A-000000000-0000 Registration Date/Time: 2013/06/27 13:11:05 HERS Provider: CalCERTS, Inc 3lectronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/27/2013 3lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/27/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN Z Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 612712013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. ,,rr.,+^� z� J..•-^.�...w r, � �-.-r �.,4 L r ; .r..� �AF'.`'*R HERS REQUIREDYERIFICATION Items in this section require field testing grid/or verification by a certified HERS Rater. --The ' inspector-m st receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System Bryant 315JAV048090 includes credit fora 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC. unit located totally. within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 3.5T Carrier includes credit for verified adequate airflow. -A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that.duct leakage meets the specified criteria. The Cooling System Bryant 315JAV048090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally verify the installation of the HVAC unit and all Ducts and Plenums. ith4i CUn—diti6nead �.acb. A certified' ER'S-rater �� e r. �I L �LiI M o r-r _ _ __ / P\ r PIT must visually The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certified System. Jerificatiob,and P r' er-iraust diagnosticallyrneasuFe airftow A p.ppr)0,/F f the HVAC The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field leakage meets the specified criteria. c/iagno ti,U- t'- -is-r quirad to v FUI-S l�l�I\lb F"iUU I1, �ify that duct EnergyPro 5.1 by EnerqySoft User Number: 8165 Run Code: 2013-06-27T10"01:25 __ ._ID: 626-49 I Page 2 of 5 Reg: 213-N0047629A-000000000-0000 Registration Date/Time:'2013/06/27 13:11:05 HERS Provider: CalCERTS, Inc 3lectronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/27/2013 3lectroriically Signed at CalCERTS.con by Russell Jones (Alta Verde Builders) 6/27/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date CORAL MOUNTAIN - PLAN Z ❑ Multi Family ❑ Existing+ Addition/Alteration 6/27/2013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV kBtu/ft2- r North East Souih west Space Heating 4.32 4.68 -0.36 3.41 0.91 3.65 0.67 4.33 -0.01 Space Cooling 70.18 41.40 28.78 47.41 22.77 48.32 21.86 48.97 21.21 Fans 13.96 15.19 =1.23 17.23 -3.28 17.57 -3.62 17.71 -3.75 Domestic Hot Water 13.47 9.59 3.88 9.59 3.88 9.59 3.88 1 9.59 3.88 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 101.93 70.86 31.07 77.65 24.28 79.13 22.79 80.60 21.33 Percent Better Than Standard: 30.5 % 23.8 % 22.4 % 20.9 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (Ej 713 421 Fuel Available at Site: Natural Gas (S) 808 88 Raised Floor Area: 0 (Kq 387 47 Slab on Grade Area: 0 (N) 506 44 Average Ceiling Height: 11.1 Roof 2,708 0 Fenestration Average U-Factor: 0.46 . TOTAL: 600 Average SHGC: 0.32 Fenestration/CFA Ratio: 22.2 % REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed , to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GMEP Engineers 6/27/2013 Address 4400 Campus Drive Name 'Gangyi Zhou City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone 9497521612 Si ned Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and ;with any other calculations submitted with this permit application, and recognizes that compliance using duct design, . duct sealing, verification.of refrigerant charge, insulation installation qua "ty; atid-btrilding-envetope-s•eafing require installer testing and. certification and field verification by an approved H RS ra�t�rY OF LA (UIN FA Designer or Owner (per Business & Professions Code) BUILDING & SAFETY DEPT. Company POON DESIGN INC APPROVED. Address 315 S. Beverly Drive, Suite 206 Name" FOR CONSTRUCTION City/State/Zip Beverly Hills, CA 90212 Phone 310-277-8855 SignedLicense # I Date n TF BY- _ Ener�qyPro 5.1 by EnerqySoft User Number: 8165 . RunCode: 2013-06-27T10:01:25 ID: 62649 Page, 3 of 5 Reg: 213-N0047629A-000000000-0000 Registration"Date/Time: 2013/06/27 13:11:05 HERS Provider: CalCERTS, Inc :lectronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/27/2013 'lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/27/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN Z Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 612712013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Wall 84 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Wall 247 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 258 0.069 R-21 180 90 New , 4.3.1-A6 Conditioned Area Roof 1,117 0.028 R-38 0 0 New 4.2.2-A 19 Conditioned Area Wall 462 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 45 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Roof 625 0.028 R-38 0 0 New 4.2.2-A19 Conditioned Area Wall 256 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Wall 462 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Roof 966 0.028 R-38 0 0 New 4.2.2-A 19 Conditioned Area FENESTRATION SURFACE DETAILS ID Type I Area 0-Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 220.2 0.560 NFRC 0.32 NFRC 90 New Fleetwood Conditioned Area 2 Window 35.3 0.380 NFRC 0.34 NFRC 90 New Fleetwood(1) Conditioned Area 3 Window 28.2 0.290 NFRC 0.29 NFRC 90 New Plastpro Low E Conditioned Area 4 Window 22.0 0.290 NFRC 0.33 NFRC 180 New Anderson Double Pane Low E(1 Conditioned Area 5 Window, .. 22.0 0.290 NFRC 0.33 NFRC 180 New Anderson Double Pane Low.E(1 Conditioned Area 6 Window' 22.0 0.310 NFRC -,'0.31 NFRC <N 0 New >` Anderson Double Pane'Low E(3 Conditioned Area 7 Window 622.0 0.310 NFRC 0.31 NFRC 0 New Anderson Double Pane Low E(3 Conditioned Area 8 Window 137.0 Z0.560 NFRC ' 0.32 NFRC • _f 90 New . -,5- Fleetwood X Conditioned Area 9 Window 10:4 J 0.290 NFRC 0.33 NFRC 1i 270 New Anderson Double Pane Low E(1 Conditioned Area, 10 Window 0 ] 10.4. , 0.290 NFRC 0.33 NFRC ,270 New -1 Anderson Double Pane Low E(1 Conditioned Area 11 Window.1 , 6.7 . _ 0.280 NFRC, - 0.28 NFRC ' - 270 New t;; Andersen Double Pane Low E(2 Conditioned Area:? 12 Window 6.7 0.280 NFRC 0.28 1 NFRC 270 New Andersen Double Pane Low E(2 Conditioned Area 13 Window 10.3 0.290 NFRC 0.33 NFRC 270 New Anderson Double Pane Low E 1 Conditioned Area 14 Window 2.8 0.290 NFRC 0.33 NFRC 270 New Anderson Double Pane Low E(1 Conditioned Area 15 Window 22.0 0.310 NFRC 0.31 NFRC 180 New Anderson Double Pane Low E(3,Conditioned Area 16 Window 22.0 0.310 NFRC 0.31 NFRC 180 New Anderson Double Pane Low E(A Conditioned Area (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin Hcit TWd Len H t LExt RExt Dist Len Hcit Dist Len H t 1 Bug Screen 0.76 2 Roll -down Blind or Slats. 0.13 3 Bug Screen 0.76 4 Roll -down Blind or Slats 0.13 5 Roll -down Blind or Slats 0.13 6 Roll -down Blind or Slats 0.13 7 Roll -down Blind or Slats 0.13 8 Bug Screen 0.76 9 Roll -down Blind or Slats 0.13 10 Roll -down Blind or Slats 0.13 n Cl 1 A 4-NI 11. %, r r• A M 11 Roll -down Blind or Slats 0.13 ' a ' _W�%_10 1 1 4 N f_% 12 Roll -down Blind or Slats 0.13 L ING zSAF I w 13 Roll -down Blind or Slats 0.13 1 r n / 7-7 r 14 Roll -down Blind or Slats 0.13 u Y e a ws` 1 L_ L. 15 Roll -down Blind or Slats 0.13 16 Roff-down Blind or Slats 0.13 DATE BY- EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T10:01:25 ID: 62649 Page 4 of 5 Reg: 213-N0047629A-000000000-0000 Registration Date/Time: 2013/06/27 13:11:05 HERS Provider: CalCERTS, Inc electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/27/2013 lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/27/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN Z Building Type ❑ Single Family ❑ Addition Alone Date ❑ Multi Family ❑ Existing+ Addition/Alteration 6/27/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft Volume Year Built New Existing Altered Removed 3.5T Carrier COMMON AREA 1,117 15,638 3.5T Carrier Master Bed 625 5,625 Bedrooms/Library 966 8,694 Totals 2,708 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status 3.5T Carrier 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 3.5T Carrier 1 Central Furnace. 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION A i Ad System Name Heating Cooling Duct Location ` 'Duct):.. R-Value Ductsv'c Tested? Status 3.5T Carrier Ducted Ducted Conditioned 6.0 m New 3.5T Carrier Ducted Ducted Conditioned 6.0 m New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or -Pilot Ext. Tank Insul. R- Value Status RTG-95DM 1 Instant Gas Kitchen Pipe Ins 199,900 0 0.84 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC_HEAT_ING SYSZEWELMNIG Control Hot Water Piping Length ft c 0 c — CrFY OF L BUILDING & SAFETY KR01pe S sty-N,in XQUI „Lpn-t JTA DEPT. Pipe iame r Insul. Thick. Qt . HP Plenum Outside Buried ❑ l , , ❑ ) DATE B EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T10:01:25 ID: 62649 Page 5 of 5 Reg: 213-N0047629A-000000000-0000 Registration Date/Time: 2013/06/27 13:11:05 HERS Provider: CalCERTS, Inc MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name CORAL MOUNTAIN - PLAN Z Date 6/27/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the. documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stri ed; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM Ell 677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no qreater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping -insulated -between -insulated-between-heating-sourced ' d' water tank shall be insulated to Table 150-B and Equation 150-A. (`ITV nr: I . A f-%I I1IN ect hot �,f. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 si,; meets the r'ec�u'rements of Stan� 123-A. BURLDING & SAFETY DEPT. lards Table 150 ' 3A: Insulation is protected from damage, includingthat due to sunlight, moisture, 6 u�men maintenance end wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapgDrettant�o�-is eho[o� e�eqtirely i conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. BY EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T10:01:25 ID: 62649 Page 8 of 14 6 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 6/27/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CIVIC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a):.Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve re uirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with.lntegral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire ass ecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket: 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7. §.150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control_system:;_amd-all-permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and tiility-rooms are@high effircac,`y�and�cdn! rd1led by a V �r-+ manual -on occupant sensor. 1° r � T §150(k)9: Permanently installed lighting that is internal to cabinets shall use non oreiChanF201awah!g of=power per linear foot f illuminated cabinet. .. I Lei. e i d N �.= W ►� FOil CONSTRUCTION •—� BY EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T10:01:25 ID: 62649 Page 9 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 6/27/2013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables.the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130 d . §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low,efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CI-N OF L.A CCU I NTA BUILDING & SAFETY.DEPT. X PROVED FOR CONS rRUCTION DATE EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T10:01:25 ID: 62649 Page 10 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 6/27/2013 •1 ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Margin Margin Standard % Better* Space Heating 4.32 4.68 0.3631.07 101.93 = 30.5 Space Cooling 70.18 41.40 28.78 Cooling Standard Heat Rejection 0.00 0.00 0.00 28.78 / 70.18 = 41.0 Indoor Fans 13.96 15.19 -1.23 Incentive Eligibility Yes No Domestic Hot Water 13.47 9.59 3.88 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) m ❑ Conditioned Floor Area = 2, 708.0 ft-- TOTALS: 101.93 70.86 31.07 Number of Bedrooms = 3 Energy Star V3 Target = 19 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing North Peak Demand kW 8.4 5.s 1 2.8 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 73.17 0.00 79.39 0.00 -6.21 Space Cooling 8,586.40 0.00 4,950.11 0.00 3,636.29 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,855.12 0.00 1,963.13 0.00-108.01 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 10,441.52 318.51 6,913.24 253.72 3,528.28 64.79 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from step2) Rate from Ste 3 Subtotal Electricity (kWh) 30.5 % �> 0.87 X1 3,528.28 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) X 2.8 = $426 NOT GUARANTEED. Projects must meet all other program requirements to qualify. $/kW kW Natural Gas 30.5 % 3.49 x 64.79 �� _ $226 Potential incentives are $/them, them, subject to program limitations 2013 Code Preparation = $o Pacific Gas and Electric Company NSHP Tier 11 = $o V SOUTHERN C461FORNIA . Total ED I S O N Incentive rate is capped at the 45% level An FDISOA' IA'773He\`A CompanyOF .1y1L* LA Q U I NTA Zgj g p b,,& SAFETY DEPT. A Sempra Energy miny` „�01�.OVED CaH � CONSTRUCTION The adva MGas Company Y Yced-h6mes'-1 D A A" Sempra Energy utiiity- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T10:01:25 /D: 62649 Page 11 of 14 CAHPUTILITY INCENTIVE WORKSHEET UTIL-1 R ct Name Date L13 RAL MOUNTAIN - PLAN Z 612712013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard % Better* Space Heating 4.32 3.41 0.91 24.28 / 101.93 = 23.8 Space Cooling 70.18 47.41 22.77 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 22.77 / 70.18 Indoor Fans 13.96 17.23 -3.28 Incentive Eligibility Yes No Domestic Hot Water 13.47 9.59 3.88 Owner Incentive (> 15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 2,708.0 ft2 TOTALS: 101.93 77.65 24.28 Number of Bedrooms = 3 Energy Star V3 Target = 19 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing East Peak Demand kW 8.41 15.61 2.8 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity -Natural Gas kWh therms kWh therms kWh therms . Space Heating 0.00 73.17 0.00 57.84 0.00 15.33 Space Cooling 8,586.40 OAO 6,127.34 0.00 2,459.06 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,855.12 0.00 2,361.99 0.00-506.87 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 1 0.00 0.00 0.001 0.00 TOTALS: 10,441.52 318.51 1 8,489.33 232.18 I 1,952.19 1 86.33 - • , POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from ste 2) Rate from Step 3 Subtotal Electricity (kWh) 23.8 % ��' 0.68 X1 1,952.19 = $1,327 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 23,s % � 11s x 2.8 = $333 NOT GUARANTEED. Projects must meet all other program �� $/� kW kw Natural Gas 23.s % X1 - requirements to qualify. 2.72 86.33 $235 Potential incentives are $/them, therm subject to program limitatioris 2013 Code Preparation = $o Pacific Gas and Electric Company l 4. NSHP Tier II = $o SOUTHERN CALIFORNIA Total EESON• Incentive=retells caT ppe'd at a 45% level An F.1)1SOA`M'77iR\'g770.\ylL^ Company ITY OF LA.QUINTA SDGE U G & SAFETY DEPT. DROVED A Sempra Energy vrGly` R Cp�iSTRUCTION califor ia The Gas ad�can e TM Company A Sempra Energy uurly- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 Run Code: 2013-06-27T10:01:25 ID: 62649 Page 12 of 14 I 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 6/27/2013 •1 ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Margin Margin Standard % Better* Space Heating 4.32 3.65 0.67 22.79 / 101.93 Space Cooling 70.18 48.32 21.86 Cooling Standard Heat Rejection 0.00 0.00 0.00 21.86 / 70.18 = 31.1 Indoor Fans 13.96 17.57 -3.62 Incentive Eligibility Yes No Domestic Hot Water 13.47 9.59 3.88 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 2,708.0 ft2 TOTALS: 101.93 79.13 22.79 Number of Bedrooms = 3 Energy Star V3 Target = 19 % . • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing South Peak Demand kW 8.4 6.2 1 2.2 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 73.17 0.00 61.80 0.00 11.38 Space Cooling 8,586.40 0.00 6,117.56 0.00 2,468.85 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,855.12 0.00 2,367.01 0.00-511.89 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 1 0.001. 0.00 1 0.00 0.00 0.00 0.00 TOTALS: 1 10,441.52 318.51 1 8,484.57 236.13 1,956.95 82.38 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available from step 2) Rate from Ste 3 Subtotal only through the California Electricity (kWh) 22.4 % �� o.s4 xi 1,956.95 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 22.4 % �' 112 x 2.2 = $246 NOT GUARANTEED: Projects must meet all other program $/� kw Natural Gas 22.4 % X1 �� requirements to qualify. 2.5s - 82.38 $211 Potential incentives are $/them, therm subject to program limitations 2013 Code Preparation = $o PacificGaSand. I Electric Company II $o NSHP Tier = 0 SOUMERN CALIFORNIA• Total = 1,709 ED I S O N -In en 've rat@Is ca� �p`e�d�at the 4 % level C�tU �f 1 j-i r„IiDfSU\'f,\'7TiHNAY'IU.VAL'�on,pen,. CITY O ING & SAFETY DEPT. B SD E �a RPROED A sem ra Energy fy` FOR CONSTRUCTION cafl r o �. The Gas a� vand Company A AD lk- Sempra Energy Remy` EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T10:01:25 /D: 62649 Page 13 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 6/27/2013 •1 ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Mar In Standard % Better' Space Heating 4.32 4.33 -0.01 21.33 / 101.93 = 20.9 Space Cooling 70.18 48.97 21.21 Cooling Standard Heat Rejection 0.00 0.00 0.00 21.21 / 70.18 = 30.2 Indoor Fans 13.96 17.71 -3.75 Incentive Eligibility Yes No Domestic Hot Water 13.47 9.59 3.88 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 2,708.0 ft2 TOTALS: 101.93 80.60 21.33 Number of Bedrooms = 3 Energy Star V3 Target = 19 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing West Peak Demand kW 8.41 1 1.4 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 73.17 0.00 73.40 11 0.00 -0.23 Space Cooling 8,586.40 0.00 5,779.58 0.00 2,806.82 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,855.12 0.00 2,241.96 0.00-386.84 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 10,441.52 318.51 8,021.54 1 247.73 2,419.98 70.78 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available from step 2) Rate from Ste 3 Subtotal only through the California Electricity (kWh) , o.so x1 2,419.98 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 2o.s % -- 104 X1 1.4 = $146 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 20.9 °� �� 2.39 x 70.78 = $169 requirements to qualify. Potential incentives are $/therm therm subject to program limitations 2013 Code Preparation = $o Pacific Gas and • Electric Company NSHP Tier II = $o SOUTHERN CALIFORNIA F1 Total ----.-=_ -- $1,767 -BUILDING E D I S O N'Aff O I ce ive�P'ate is'c`aped itatie 5% level An EAISOA' F.\T'IiR\'aT'fU\'A/.^ Compnm &SAFETY DEPT. sE ��VED• ia Sempra Energy utility caIif orn CONSTRUCTIONA The Gas advwancT TAI Company A aSempraEnergy uumy- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-27T10:01:25 ID: 62649 Page 14 of 14 BUILDING ENERGY ANALYSIS REPORT PROJECT: CORAL MOUNTAIN ACCESSORY A LA QUINTA, CA Project Designer: POON DESIGN INC 315 S. Beverly, Drive, Suite 206 Beverly Hills, CA 90212 310-277-8855 Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521612 Job Number.: 62649 Date: CITY OF LA QUANTA BUILDING & SAFETY DEPT.: 6/28/2013 APPROVED FOR CONSTRUCTION The EnergyPro computer program has been used to perform the calculations summarized in thisico�mptiance report.•This_fird§ram_has-approval-and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy—Ujci.encyStaradards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 5.1 by Energ Soft User Number: 8165 RunCode: 2013-06-28T16:46:40 ID: 62649 TABLE OF CONTENTS Cover Page Table of Contents Form CF-1 R Certificate of Compliance Form MF-1 R Mandatory Measures Summary. - Form UTIL-1 R Utility.lncentive Worksheet 1 2 �3 8 11 EnergyPro 5.1 by EnergySoft Job Number: ID: 62649 . User Number: 8165 ^electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/28/2013 'electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/28/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name CORAL MOUNTAIN ACCESSORY'A Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/28/2013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 184 Addition n/a # of Stories 1 FIELD INSPECTION ENERGTCHECKLIST ❑ Yes ❑ No 'HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavit (e) Features (see Part 2 of 5) Status Wall Wood Framed R-21 .430 New Roof Wood Framed Rafter R-38 184 New FENESTRATION U- Exterior Orientation Area(fe) Factor SHGC Overhang Sidefins Shades Status - Rear (E) 48.0 0.290 0.33 none none Bug Screen New Rear(E) �.-, r, 28.2 0.290,. 0.29 ._none.., ,_.none r: ,;,,,..Bug Screen,, New 7 All HVAC SYSTEMS Ot . Heating Min: Eff Cooling Min._ Eff Thermostat Status 1 Split Heat Pump 10.00 HSPF Split Heat Pump 19.2 SEER Setback New HVAC DISTRIBUTION ci 0FbU1- to QUfNTA Location. Heating Cooling Duct Locatio'lOUILU11�IG R V.,arLWTY [%0s 1.5T Carrier Ducted Ducted Conditioned 3P P �6 0n\ FE ew FOR CONSTRUCTION WATER HEATING DATE BY Ot . Type Gallons Min. Eff' Distribution 1 Instant Gas 0 0.84 Kitchen Pipe Ins New Energ Pro 5.1 by Energ Soft User Number: 8165 . RunCode: 2013-06-28T16:46:40 ID: 62649 Page 1 of 5 Reg: 213-N0048306B-000000000-0000 Registration'Date/Time: 2013/06/28 19:49:29 HERS Provider: CalCERTS, Inc 3lectronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/28/2013 3lectronically Signed at Ca10ERTS.com by Russell Jones (Alta Verde Builders) 6/28/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN ACCESSORY A Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/28/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special 'ustification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. „s �"A �7 ��i' f rs''"._ "_�''� � 1,.+.,'1 1 ��"�`-.\'."t,. _ r f•^ � `�,., . j � fi:. �`-7+ HERS REQUIRED�VERIFICATION '. Items in this section require field testing'and/or verification by a certified HERS Rater' -the' inspectormust receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System 1.5T includes credit for a 13.3 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 1.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System 1.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. . The HVAC System 1.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 1.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. C 1 N I A �I O-x-� N BUILDING DIN&SAFEIY DEPT. A�.-.1� 10VEU r DATE —_--- BY Ene yPro5.lbyEnergySoft User Number. 8165 RunCode: 2013-06-28T16:46:40 ID: 62649 Page 2 of 5 Reg: 213-N0048306B-000000000-0000 Registration Date/Time: 2013/06/28 19:49:29 HERS Piovider: CalCERTS, Inc ?lectronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/28/2013 electronically Signed at CalCERTS.com by Russell Jones ,(Alta Verde Builders) 6/28/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date CORAL MOUNTAIN ACCESSORY ❑ Multi Family ❑ Existing+ Addition/Alteration 6/28/2013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV kBtu/ft2- r North East South West Space Heating 5.89 2.69 3.20 3.14 2.76 3.20 2.69 2.37 3.53 Space Cooling 156.96 114.84 42.12 118.22 38.74 94.18 62.78 110.35 46.61 Fans 32.35 46.61 -14.27 46.41 -14.07 37.53 -5.18 44.65 -12.30 Domestic Hot Water 110.17 50.96 59.21 50.96 59.21 50.96 59.21 50.96 59.21 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 305.37 215.10 90.26 218.73 86.64 185.87 119.50 208.32 97.04 Percent Better Than Standard: 29.6 % 28.4 % 39.1 % 31.8 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four Orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (K9 162 0 Fuel Available at Site: Natural Gas (N) 91 0 Raised Floor Area: 0 (E) 162 76 Slab on Grade Area: 0 (S) 91 0 Average Ceiling Height: 9•0 _ Roof 184 0 Fenestration Average U-Factor: 0.29 TOTAL: 76 Average SHGC: 0.32 Fenestration/CFA Ratio: 41.4 % REMARKS f'f �R- ILI. STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts"I the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. ' The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GMEP Engineers Address 4400 Campus Drive Name Gangyi.Zhou _ 6/28/2013 City/State/ZipCity/State/Zip Newport Beach, 'CA 92660 Phone 9497521612 Signed r Date The individual with overall design responsibility hereby certifies that the proposed buildingTdEsign-epNresente m is set' of construction documents is consistent with the other compliance forms and' worksheets with LI IV Speciflicf ?k n I and with any other calculations submitted with this permit application, and recogriizeslthafcompliancerr-is�'�tit'g[daa?lesi gn, duct sealing, verification of refrigerant charge, insulation installation quality, and building-enwelloop6's�li� requir installer testing and certification and field verification by an approved HER rater. :,O ISTRUCTION Designer or Owner (per Business & Professions Code) I Company POON DESIGN INC DATE BY Address 315 S. Beverly Drive, Suite 206 Name City/State/Zip Beverly Hills, CA 90212 Phone 310-277-8855 Signed License # ; Date Ener Pro 5.1 by EnerqySoft User Number: 8165 RunCode: 2013-06-28T16:46:40 /D: 62649 Page 3 of 5 Reg: 213-N0048306B-000000000-0000 Registration Date/Time:_2013/06/28 19:49:29 HERS Provider: CalCERTS; Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/28/2013 31ectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/28/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN ACCESSORYA Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/28/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Wall 91 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 91 0:069 R-21 180 90 New 4.3.1-A6 Conditioned Area Wall 86 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 162 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Roof 184 0.028 R-38 . 0 0 New 4.2.2-A 19 Conditioned Area FENESTRATION SURFACE DETAILS ID Type I Area U-Factor SHGC Azm . Status Glazing Type Location/Comments 1 Window 24.0 0.290 NFRC 0.33 NFRC 90 New Andersen Double Pane Low E Conditioned Area 2 Window 24.0 0.290 NFRC 0.33 NFRC - 90 New Andersen Double Pane Low E Conditioned Area 3 Window' 28.2 0.290 NFRC 0.29 NFRC. 90 New Plastpro Low E Conditioned Area I (1) LI-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS - ID Exterior Shade Type SHGC Window Ove hang Left Fin Ri ht Fin H t Wd -Len H t I-Ext RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 1 f_"i, n i I I h IT Z),-1rL7 r Y U = I f _ u`" I I EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:46:40 ID: 62649 Page 4 of 5 Reg: 213-N0048306B-000000000-0000 Registration Date/Time: 2013/06/28 19:49:29 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/28/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/28/2013 CERTIFICATE OF COMPLIANCE: Residential - �. (Part 5 of 5) CF-1 R Project Name CORAL MOUNTAIN ACCESSORY A Building Type ❑ Single Family ❑ Addition Alone I Date ❑ Multi Family ❑ Existing+ Addition/Alteration 6/28/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft Volume Year Built New Existinq Altered Removed 1.5T Carrier AREA 184 1,656 Totals 184 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type - Min. Eff. Cooling Type Min. Eff. Thermostat Type Status 1.5T Carrier 1 Split Heat Pump 10.00 HSPF Split Heat Pump 19.2 SEER Setback New HVAC DISTRIBUTION ,� r , i / t. . - • r s: , i, System Name •.,. - Heating _. Coolinq ' . c s ._ Duct Location Duct `u R-Value 4 { Ducts'!'� Tested? Status 1.5T Carrier Ducted Ducted Conditioned 6.0 m New WATER HEATING SYSTEMS S stem Name city. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status RTG-95DVN 1 Instant.Gas Kitchen Pipe Ins 199,900 0 0.84 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o 414.7� �. Q — CITY OF LA BUILDING & S System Name, r TA MPTpe Diamet r , Insul. Thick. QUI Fhipe' t qr1 • t Qty. HP Plenum Outside Buried ❑ ��� I I 1 10 _ ❑ F 15iNuu ❑ 4 _ ❑ nAT- oy EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:46:40 ID: 62649 Page 5 of 5 .Reg: 213.N0048306B-000000000-0000 Registration'Date/Time: 2013/06/28 19:49:29 HERS Provider: CalCERTS, Inc MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name CORAL MOUNTAIN ACCESSORYA Date 1 6/28/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- I R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed acc�orclinq to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no cIreater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non'reeirculating.syste((nr�s`�,j,and entire leng/l o recirculatingsections of hot water pipes are insulated per Standards Table 150-B. (.`. i y OF iL/X Q-11IJ I N i, ` ` §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping; insulated:between heating=sou�oe�ari ndi�°ect hot [.7 �.Jif...0 9 oUe Jl �e •i water tank shall be insulated to Table 150-B and Equation 150-A. �, „r- §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psij' 66ts tKdJ.ecf61(etnent of Stan ards Table 123-A. P 1" )nl RUCTION 150 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, a ui ment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is Viclosed entirely in conditioned space. DATE 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Ratin" an-d Certification —Co r oration. EnergyPro 5.1 by EnergySoft User Number. 8165 RunCode: 2013-06-28T16:46:40 ID: 62649 Page 8 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN ACCESSORY 6/28/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CIVIC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor poolsors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires. or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or, greater shall be electronic and shall have an output. frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the a licable're uirements of §150(k). 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens-shalhbe-high-efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 10,0,wattsfovdwNelliP ?Anits Iarge1Nfha91_` b0 ft2 may be exempt from the 50 /o high efficacy requirement when: all low efficacy luminaires in'tfie-kitcherr are contro�iled b ��ual on occupant ci �n A JnF �' ( ` . sensor, dimmer, energy management system (FMCS), or a multi scene programmable ci5ntri%lasyste.�m;�amd�all installed . v,�� per�ian'entl luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms -are -high efficacy and t ontroIIe> by a �- manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more tFfdb 20ai Wfnear foot of illuminated cabinet. DATE —_---- BY 4 EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:46:40 ID: 62649 . Page 9 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A 6/28/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high. efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including fighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or`other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130 d . . §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more . dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply'with the applicable requirements of 119. CITY OF LA QUINTA BUILDING &..ySAFETY DEPT. r-PF110 V ED FOR CONSTRUCTION _), ,TE BY. EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:46:40 ID: 62649 Page 10 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A 6/28/2013 •1 ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Margin Margin Standard % Better' Space Heating 5.89 2.69 3.20 90.26 / 305.37 = 29.6 Space Cooling 156.96 114.84 42.12 Cooling Standard Heat Rejection 0.00 0.00 0.00 42.12 / 156:96 = 26.8 Indoor Fans 32.35 46.61 -14.27 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) 10 ❑ Pumps 0.00 0.00 J 0.00 NSHP Incentive (>=30%) ❑ l�l Conditioned Floor Area = 184.0 f 2 TOTALS: 305.37 215.10 90.26 Number of Bedrooms = 1. Energy Star V3 Target = 15 % , • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing North Peak Demand kW 1.1 1 0.81 1 0.2 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas 7 Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 102.31 0.00 46.68 0.00 55.63. 0.00 Space Cooling 1,431.36 0.00 1,095.97 0.00 335.40 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 477.44 0.00-160.30 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.001 0.00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1,620.008 62.94 230.73 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive. Savings on this report are available only through the California from step 2) Rate from Ste 3 Electricity (kWh) 2s.s % �> 0.85 X 230.73 = Subtotal $196 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) X 0.2 = $30 NOT GUARANTEED: Projects must meet all other program requirements to qualify. $/kW kW Natural Gas 2s.s % �� 3.38 X1 73.52 = $248 Potential incentives are $/therm therm subject to .program limitations. 2013 Code Preparation = $o Pacific.Gas and Electric CO/ipanj/ NSHP Tier II = $o CITY OF LA QUINTA SouTHraN CALIFORNIA J i CSt,.;iLEI[MG & ST&FITY DEFT $474 ED I S O N° i 7-1 .-171 `Incen 've'rate`is capped a the 45% level An Company ! R,'R COfd13 RUCTION SD A *Sempra Energy urrfy°cafifdrnia BY Th advanced homes TM . CGas ompany A a.. Sempra Energy aumy- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:46:40 0: 62649 Page 11 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A 6/28/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Margin Margin Standard % Better* 7[86.64 Space Heating 5.89 3.14 2.76 / 305.37 = 28.4 Space Cooling 156.96 118.22 38.74 Cooling Standard Heat Rejection 0.00 0.00 0.00 38.74 1 156.96 Indoor Fans 32.35 46.41 -14.07 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 184.0 ft2 TOTALS: 305.37 218.73 86.64 Number of Bedrooms = 1 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing East Peak Demand kW 1.1 1.0 1 0.1 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 102.31 0.00 53.16 0.00 49.15 0.00 Space Cooling 1,431.36 0.00 1,042.54 0.00 388.82 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 441.12 0.00-123.98 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.00 1 0.00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1,536.82 62.94 1 313.99 1 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from ste 2) Rate from Step 3 Subtotal Electricity (kWh) 28.4 % �' 0.81 x 313.99 = $254 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) x 0.11 = $14 NOT GUARANTEED. Projects must meet all other program �� $/� kW kw Natural Gas 28.4 /0 3.25 x 73.52 = $239 requirements to qualify. Potential incentives are $/them, them, subject to program limitations 2013 Code Preparation = $o Pacific Gas and Electric Company SIT, OF N PQU I NP $o SJ,DING & SAFETY DE_P . SOUIHFRN CALIFORNIA -. Total $507 �..i -0 �v.r�. EDISON' � Incentive rate•is-cApped at th 45% level .i-.DNS FRUCTION An EDISON IATGR:Vt1770NAl.* Compuny SDFE �t ate- BY A �/Sempra Energy urrly* cdomimrn aTh a advancedh'o'mes TM CGas ompany E A Sempra Energy mluly- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:46:40 /D: 62649 Page 12 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A 612812013 •1 ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard % Better* Space Heating 5.89 3.20 2.69 119.50 / 305.37 = 39.1 Space Cooling 156.96 94.18 62.78 Cooling Standard Heat Rejection 0.00 0.00 0.00 62.78 / 156.96 = 40.0 Indoor Fans 32.35 37.53 -5.18 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) 10 ❑ Conditioned Floor Area = 184.0 ft2 TOTALS: 305.37 185.87 119.50 Number of Bedrooms = 1 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing South Peak Demand kW 1.1 1 0.71 1 0.3 EStandard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 102.31 0.00 54.16 0.00 48.15 0.00 Space Cooling 1,431.36 0.00 844.14 0.00 587.22 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 362.67 0.00 -45.53 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1,260.97 62.94 589.84 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from step 2) Rate from Ste 3 Subtotal Electricity (kWh) 3s.1 % �> 1.12 X 589.84 = $661 Advanced Homes Program for . $/kWh kWh new construction and are Electricity (kW) 3s.1 °i° �� 1ss X 0.3 = $59 NOT GUARANTEED. Projects must.meet all other program requirements to qualify. $/kw kw Natural Gas 3s.1 °�° �'� 4.47 X 73.52 = $329 Potential incentives are $/therm therm subject to program_ limitations 2013 Code Preparation = $o Pacific Gas and Electric Company CITY O F INs1HU Ldri fl�� � $o EUi11-01NG & SAFETY DEPT: SOUTHERN CALIFOItNIA - Ota)l �" �� �HT �.. EDISON° p 9 � � ^,yj*�SIncent�p,��ra�q�`s �ped at t e 45%level L.11"i L• An POISON INTERNA770N110 Company i Al. BY A *Sempra Energy miry` Th cafif6rnia a_STM is �W h Company �J� tJ+I u Y A Sempra Energy uiany- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:46:40 /D: 62649 Page 13 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY 6/28/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard % Better* Space Heating 5.89 2.37 3.53 97.04 / 305.37 = 31.8 Space Cooling 156.96 110.35 46.61 Cooling Standard Heat Rejection 0.00 0.00 0.00 46.61 / 1 156.96 Indoor Fans 32.35 44.65 -12.30 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (> 15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (> 30%) ❑ m Conditioned Floor Area = 184.0 ft2 TOTALS: 305.37 208.32 97.04 Number of Bedrooms = 1 Energy Star V3 Target = 15 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing West Peak Demand kW 1.1 0.71 1 0.3 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas' Electricity Natural Gas Electricity -Natural Gas kWh therms kWh therms kWh therms Space Heating 102.31 0.00 41.60 0.00 60.71 0.00 Space Cooling 1,431.36 0.00 1,065.07 0.00 366.30 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 461.10 0.00-143.96 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.00 a00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1,567.77 62.94 1 283.05 1 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from ste 2) Rate from Ste 3 Subtotal Electricity (kWh) 31.8 % �� 0.91 X 283.05 = $258 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) X 0.3 = $48 NOT GUARANTEED. Projects must meet all other program $/� kW kw = Natural Gas 31.8 /0 X requirements to qualify. 3.64 73.52 $268 Potential incentives are $/therm them, subject to program limitation's 2013 Code Preparation = $o Pacific Gas and Electric Company NSHP Tier n = $o CAI a ° OF LA QUINT 111 SOUIHERNCALIfORNIA S !, Ir�IL.DING & SrT�otA1N DEPz $574 E D I SO N` 1 Incentiveq t is capped a the 45% level An liUlSU,\' fA'TERA'ATlUNAI." Compuny r� „ I I-IL]^A� 7IO C,���� I 'V SOLE:�,�3 A Sempra Energy ultrly¢ l `BY Gas call Orni VA a dvanced homes7M CTh ompany A Sempra Energy uuufy- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:46:40 /D: 62649 Page 14 of 14 � BUILDING ENERGY ANALYSIS REPORT PROJECT: CORAL MOUNTAIN ACCESSORY A OPTION LA QUINTA, CA Project Designer: POON DESIGN INC 315 S. Beverly Drive, Suite-206 Beverly Hills, CA 90212 310-277-8855 Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521612 Job Number: 62649 FCITY OF i a QUINTq SUILUNG & SAFETY DEPT. _� Date: tfi.�t -k ROVED VONSTROCTION 6/28/2013 �•�� The EnergyPro computer program has been used to perform the calculations summarized in this compliance repo i's'p� lam-has-a�pr. val and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:45:27 ID: 62649 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory. Measures Summary 8 CITY OF LA QUINTA BUILDING & SAFETY DEPT. BY- Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/28/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/28/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name CORAL MOUNTAIN ACCESSORYA OPT Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/28/2013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 184 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavit� (ft) Features see Part 2 of 5 Status Wall Wood Framed R-21 373 New Roof Wood Framed Rafter R-38 184 New FENESTRATION U- Exterior Orientation Area(ftz) Factor SHGC Overhang Sidefins Shades Status Rear (E) 133.4 0.560 0.32 none none Roll -down Blind or Slats New V r� HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 10.00 HSPF Split Heat Pump 19.2 SEER Setback New HVAC DISTRIBUTION Duct Location. Heating Cooling Duct Loca ,-. , - a ue , S u" r Y Ld r K- %i LaC v Y Y WI 1 rA .. 1.5T Carrier . Ducted Ducted Conditioned _ 6:0� .w. Lai %.>r%l L— 1 I lJ L 1 1 . ' �.�•4,jwVf E -1 WATER HEATING l:1Ji t i;lJ1w rsv% lulu Ot . Type Gallons Min. Eff Distribution Statu 1 Instant Gas 0 0.84 Kitchen Pipe InsT ` is New Energ Pro 5.1 by Energ Soft User Number: 8165 RunCode: 2013-06-28T16:45:27 ID: 62649 Page 1 of 5 Reg: 213-N0048307A-000000000-0000 Registration Date/Time: 2013/06/28 19:50:06 HERS Provider: CalCERTS, Inc 3lectronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/28/2013 'electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/28/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name 4 CORAL MOUNTAIN ACCESSORY A OPTI Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration . Date 6/28/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the s ecial •ustification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. HERS REQUIRED ,VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater,'. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System 1.5T includes credit for a 13.3 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 1.5T Carrier includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System 1.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System 1.5T Carrier has Ducts, Plenums and the HVAC unit located totally, within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 1.5T Carrier includes credit for verified adequate airflow.. A certified HERS rater must diagnostically measure airflow of the HVAC System. . The HVAC System 1.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is.required to verify that.duct leakage meets the specified criteria. t.�r LA 0U11 5OUED "'OR CONSTRUCTION - BY EnerqyPro 5.1 by EnerqySoft User Number: 8165 RunCode: 2013-06-28T16:45:27 ID: 62649 Page 2 of 5 Reg: 213-N0048307A-000000000-0000 Registration Date/Time:'2013/06/28 19:50:06 HERS Provider: CalCERTS, Inc ~Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com 6/28/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/28/2013 PERFORMANCE CERTIFICATE: Residential I (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date CORAL MOUNTAIN ACCESSORYA OPTI ❑ Multi Family ❑ Existing+ Addition/Alteration 6/28/2013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin . Facing Margin TDV kBtu/ft2- r North East South West Space Heating 5.89 9.04 -3.15 9.46 -3.57 9.64 -3.75 8.63 -2.74 Space Cooling 156.96 112.03 44.93 117.14 39.82 103.23 53.73 111.08 45.88 Fans 32.35 33.45 -1.10 34.45 -2.11 30.69 1.66 33.14 -0.80 Domestic Hot Water 110.17 , 50.96 59.21 50.96 59.21 50.96 59.21 50.96 59.21 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 ` 0.00 0.00 0.00 Totals 305.37 W5.48 99.89 212.02 93.35 194.52 110.85 203.81 101.55 Percent Better Than Standard: 32.7 % 30.6 % 36.3 % 33.3 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (M 1 162 0 Fuel Available at Site: Natural Gas (N) 91 0 Raised Floor Area: 0 (E) 162 133 Slab on Grade Area: 0 (S) 91 0 Average Ceiling Height: 9.0 Roof 184 0 Fenestration Average U-Factor: 0.56 TOTAL: 133 Average SHGC: 0.32 Fenestration/CFA Ratio: 72.5 % REMARKS f it .,� dJJ � • • � ! �a STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply.with Title 24, Parts 1 the Administrative Regulations and Part 6 the, Efficiency Standards of the California Code of Regulations.' . The documentation author hereby certifies that the documentation is accurate and complete. t Documentation Author . Company GMEP Engineers Address 4400 Campus Drive Name 'Gan 9yi Zhou 6/28/2013 City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone 9497521612 _Si ed Da e The individual with overall design responsibility hereby certifies that the proposed U i 111 ing dk- esign re resented n � ihi set of construction documents is consistent with the other compliance forms and worksheets, wfhe�specifioatto.n?, ith d .a with any other calculations submitted with this permit application, and recognizes that compliancesusing- art desig . k �' duct sealing, verification.of refrigerant charge, insulation installation quality, and building envelope se tl e uire r<''r' i.�Iv� installer testing and. certification and field verification by an approved HERS rater. I t=tU� ir� Designer or Owner (per Business & Professions Code) BY Company POON DESIGN INC Address 315 S. Beverly Drive, Suite 206 Name City/State/Zip Beverly Hills, CA 90212 Phone 310-277-8855 Signed License # Date EnergyPro 5.1 by EnerlqySoft User Number: 8165 RunCode: 2013-06-28T16:45:27 ID: 62649 Page 3 of 5 Reg: 213-N0048307A-000000000-0000 Registration`Date/Time: 2013/06/28 19:50:06 HERS Provider: CalCERTS, Inc -Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/28/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde,Builders) 6/28/2013 CERTIFICATE OF COMPLIANCE: Residential .. (Part 4 of 5) CF-1 R Project Name - CORAL MOUNTAIN ACCESSORY A OPTIC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/28/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Wall 91 0.069 R-21 0 90 New 4.3.1=A6 Conditioned Area Wall 91 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Wall 29 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 162 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Roof 184 0.028 R-38 01 0 New 4.2.2-A19• Conditioned Area FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC2 AM Status Glazing Type Location/Comments 1 Window 133.4 0.560 NFRC 0.32 NFRC 90 New Fleetwood Slider Conditioned Area bz f , • 1 ! t :, r, r, / e,, r fr S ito i t A (1) Ll-Factor Type: 116-A = Default Table from Standards„NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC 'Window Ove hang Left Fin Right Fin H t Wd ' Len H t ` LEkt RExt Dist Len H t Dist Len H t 1 Roll -down Blind or Slats 0.13 ,r'` rrw rNC A 111 K I T I k l 1 %—I' 1 _J —7 %-t , V I Y r\ c_`I P4_UI Nu & 6AVE I. rUl- C_,Jl% 7 I EnergyPro 5.1 by EnergySoft User Number 8165 RunCode: 2013-06-28T16:45:27 ID: 62649 Page 4 of 5 Reg: 213-N0048307A-000000000-0000 Registration Date/Time: 2013/06/28 19:50:06 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/28/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/28/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name CORAL MOUNTAIN ACCESSORY OPTI Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date • 6/28/2013 BUILDING ZONE INFORMATION System Name Zone Name. Floor Area ft Volume Year Built New Existing Altered Removed 1.5T Carrier AREA 184 1,656 Totals 1841 01 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status 1.5T Carrier 1 Split Heat Pump 10.00 HSPF Split Heat Pump 19.2 SEER Setback New { !' • l it �. !. '4� HVAC DISTRIBUTION � .` , +# 1. ,� % ? z' , 1W System Name HeatingCooling- Duct Location ,cDuct R-Value ' Ducts= Tested? - Status 1.5T Carrier Ducted Ducted Conditioned 6.0 m New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or -Pilot Ext. Tank Insul. R- Value Status RTG-95DVN 1 Instant Gas Kitchen Pipe Ins 199,900 0 0.84 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o co 0 c — �,� ®� BUILDING & -in � S stem,_ ma e_t Q SAFE 4�Pi�ea Lenq'th I NTA DEPT'. ipe` .-t®igmeter In`sul. Thick. Qty. HP Plenum Outside Buried - ❑ j rviY �v�v I MULJ I I ❑ `���r v. EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:45:27 ID: 62649 Page 5 of 5 Reg: 213-N00483'07A-000000000-0000 Registration Date/Time: 2013/06/28 19:50:06 HERS Provider: CalCERTS, In MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name CORAL MOUNTAIN ACCESSORY A OPTION Date 6/28/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the.documents or in this summary. Submit all applicable sections of the MF-1 R . Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stri ed; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulatirig Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance'and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R_ Form. * 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. " 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate=for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no areater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures:. §110-§1'13: HVAC equipment, water heaters, showerheads, faucets. and all other regulated appliances are certified by the Energy Commission. §113(c)5' Water heating recirculation loops serving. multiple dwelling units.and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks orbackup tanks for solar water -heating system, or other indirecthot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest -to water heater tank, non -recirculating systems aod�eratite�etagtlaA recirculating sections of hot water pipes are insulated per Standards Table 150-B. a-- a A f-'Nl I 1 K §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between h"edfing1s6uice and'iridilydc Rot water tank shall be insulated to Table 150-B and Equation 150-A. ial, _►.:�;N&SAFETY DEFT. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requiremenits'of-Sta dards T 123-A. �. J — 4- in�i V l� ble 150 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture a ui merit maintendance,tan in . §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. V 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification,.Coc oration. EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:45:27 ID: 62649 Page 8 of 14 . MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A OPTION 6/28/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 1 50m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 1 50m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or procirammed to run only during.off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz: §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to.consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Li htin _, integral to exhaust fans, in rooms other than kitchens, shall meet the a JigaJ re,, utre s k 1 50k 7: All . switching devices and controls shall meet the re uirements of §150 k 7.;� I I T y r LA Qu I IN §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed ligkiffrngtin-kitc, enssh£II b"e: Vii h etfie X. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwefling-rJniit Oar e9tha 500 ft2 exempt from the 50% high are 1ahtFal ay be efficacy requirement when: all low efficacy luminaires in the kitcheA �ntfolie�d-b / n on oc pant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable contilol syst�and� tf�{�e�iTaft'ei* insta led luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. I §150(k)9: Permanently installed lighting that is internal to cabinets shall -use no more than 20 watts -of -pews illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:45:27 ID: 62649 Page 9 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN ACCESSORY OPTION 6/28/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables.the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be hi h efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:45:27 ID: 62649 Page 10 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A OPTION 6/28/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard ProDosed Mar in Margin Standard % Better* Space Heating 5.89 9.04 3.15 99.89 / 305.37 = 32.7 Space Cooling 156.96 112.03 44.93 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 44.93 / 156.96 = 28.6 Indoor Fans 32.35 33.45 -1.10 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) ❑ m Conditioned Floor Area = 184.0 ftz TOTALS: 305.37 205.48 99.89 Number of Bedrooms = 1 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing North Peak Demand kW 1.1 1 0.8 0.2 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 102.31 0.00 157.83 0.00 -55.52 0.00 Space Cooling 1,431.36 0.00 997.46 0.00 433.91 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 322.17 0.00 -5.03 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1,477.46 62.94 373.36 73.52 1 J • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from step 2) Electricity (kWh) 32.7 % �� Rate from Ste 3 Subtotal o.s4 X 373.36 = $351 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) X1 0.2 = $33 NOT GUARANTEED. Projects must meet all other program requirements to qualify. Natural Gas 32.7 % �� $/kW kW 3.74 X1 73.52 =$275 Potential incentives are $/therm ttierm, subject to program limitations -Tf -2013' Code Pr_epa atlon'IN` $0 Pacific Gas and t , _. „�s 0 &SAFETY DE • Electric Company NNSHRtJb-01Cf $o VOIVJTrIUVTION rv`I SOUTHERN CALIFORNIA I Total $659 ED I S O N' Incer E�v�g rate is capped at the %level „ T : An VINSON I N7'IiR `'A770A1A1.* Company _ Off A`SempraEnergy urrty'ro- Th Gas o= .,�.]111//�111II ���11J�J1/(�j11 II/►�1�e1�I h6mlo; ce Company V+J v v.+v �.,.i D A Sempra Energy mnuy- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:45:27 ID: 62649 Page 11 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORYA OPTION 6/28/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard % Better* Space Heating 5.89 9.46 -3.57 93.35 / 305.37 = 30.6 % Space Cooling 156.96 117.14 39.82 Cooling Standard Heat Rejection 0.00 0.00 0.00 39.82 / 156.96 = 25.4 % Indoor Fans 32.35 34.45 -2.11 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) ❑ m Conditioned Floor Area = 184.0 ftz TOTALS: 305.37 212.02 93.35 Number of Bedrooms = 1 Energy Star V3 Target = 15 % • ANNUAL SITE ENERGY USE Mar in Facing East Average 2pm - 5pm Standard . Pro77� Peak Demand kW 1..1 0.11 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh (therms),, kWh therms kWh therms Space Heating 102.31 0.00 163.65 0.00 -61.34 0.00 Space Cooling 1,431.36 0.00 1,006.62 0.00 424.75 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 320.81 0.00 -3.66 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.00 6.00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1,491.07, 62.94 F 359.74 r 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available from s6 2� Rate from Ste 3 Su btotal only through the California 0 Electricity (kWh) 3o.s / 0.88 x 359.74 = $317 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 3o.s � 153 X 0.1 = $15 NOT GUARANTEED. Projects must meet all other program �� $/� kW kw - Natural Gas 3o.s � 3.50 xi 73.52 $257 requirements. to qualify. Potential* incentives are $/them, therm subject to program limitation"s 2ti01.� Co PreparatiorT ,I $0 4 t- - Pacific Gas and i n _ L�1€LDi�IrNSHP Tler" I'I ' Electric Company .' $o e SOUTHERN CALIFORNIA' F'OR W V$TRvCT€ '89 ED I S O N° 1J otal $ Incentive rate is capped at the 450 level An F'DISON Company i -1ATE _ BY - SD A Sempra Energy mniiy` �. - califfirnia Gas advarinced omes Company 1 A Sempra Energy uuuty- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:45:27 0: 62649 Page. 12 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A OPTION 6/28/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Margin Margin Standard % Better* Space Heating 5.89 9.64 -3.75 110.85 / 305.37 = 36.3 Space Cooling 156.96 103.23 53.73 Cooling Standard Heat Rejection 0.00 0.00 0.00 53.73 / 156.96 = 34.2 Indoor Fans 32.35 30.69 1.66 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (> 15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (> 30%) m ❑ Conditioned Floor Area = 184.0 ftz TOTALS: 305.37 194.52 110.85 Number of Bedrooms = 1 Energy Star V3 Target = 15 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing South Peak Demand kW 1.1 0.8 0.3 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 102.31 0.00 166.34 0.00 -64.03 0.00 Space Cooling 1,431.36 6.00 896.17 0.00 535.19 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 289.09 0.00 28.05 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1,351.60 62.94 1 499.22 r 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from step 2) Rate from Ste 3 Subtotal Electricity (kWh) X 499.22 = $519 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) X 0.3 = $55 NOT GUARANTEED. Projects must meet all other program $/kW kW Natural Gas 36.3 % �' X = requirements to qualify. 4.15 73.521 $305 Potential incentives are $/therm therm subject to program limitations 20�-3-Code-Pre ar I� t o ��"• Pacific Gas and C1 I Electric Company��� �Nsr�P,'trtier�lfE �o SOUTHERN G1LIrORNIA + ��f���®� FO�Tetal $a7s �> E D I SON* Incentive rate is capped at the 45% leve I A.. raxson m�T•�:rr�tgC•rio.vnr.^ Company BY GATE d .-_----- Z7 A -)Sempra Energy urnly oYT a1� The rma TM v adancnA ho` CGasompany Y U U%s E A Sempra Energy urairy- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:45:27 0: 62649 Page 13 of 14 CAHPUTILITY INCENTIVE WORKSHEET UTIL-1 R ct Name Date L13 RAL MOUNTAIN ACCESSORY A OPTION 6/28/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard % Better* Space Heating 5.89 8.63 -2.74 101.55 / 305.37 Space Cooling 156.96 111.08 45.88 Cooling Standard Heat Rejection 0.00 0.00 0.00 45.88 / 156.96 = 29.2 Indoor Fans 32.35 33.14 -0.80 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) ❑ m Conditioned Floor Area = 184.0 ft2 TOTALS: 305.37 203.81 101.55 Number of Bedrooms = 1 Energy Star V3 Target = 15 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing West Peak Demand kW 1.1 0.80.3 Standard Proposed Margin. ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 102.31 0.00 151.42 0.00 -49.11 0.00 Space Cooling 1,431.36 0.00 1,000.58 0.00 430.79 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 322.17 0.00 -5.03 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.001 0.00 0.00 0.001 0.00 1 TOTALS: 1,850.82 136.46 1,474.17 62.94 376.65 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from ste 2) Rate from Ste 3 Subtotal Electricity (kWh) 33.3 % ' 0.96 X 376.65 = 1 $362 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 33.3 % 166 X 0.3 = $50 NOT GUARANTEED. Projects must meet all other program requirements to qualify. $/kw kw Natural Gas 33.3 % �� 3.81 X1 73.52 = $280 Potential incentives are $/them, therm subject to program limitations 2013 Code Preparation = $o Pacific Gas and '-'-� ITler ltl� I'� I I A$o .. Electric Company T( o�S & SAFETY DEP SOUTHERN CALIFORNIA BUILDING \ APFTr ag V ED 692 �•j` E D I S O N* FOR CO i MU' t the 45 0 level An EDISON IATERV4770NAL" Company �E T BY ASTE A Sempra Energy utility` califd Th Gas M rnia 1 adVa"mced homes'm Company . A Sempra Energy alimy- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-28T16:45:27 /D: 62649 Page 14 of 14 P 30279 : RECEIVED JUN 2 6 2013 cA��F. CITY OF LA QUINTA COMMUNITY DEVELOPMENT . 949.752.1612 Gangyi Zhou, 4400 Campus Drive • , M34279 Exp. Date 12/31 /2014 'The attached calculations are valid only when. bearing original. :. Newport Beach, CA -:signature of Gangyi Zhou, Hereon. 92660IM :� ;;' www.gouvisgroup.com Palm Springs, CA,,, Pleasanton, CA Ho Chi Minh City;.Vietnam f, , BUILDING ENERGY ANALYSIS REPORT PROJECT': CORAL MOUNTAIN -PLAN C LA QUINTA, CA Project Designer: POON DESIGN INC 315 S. Beverly Drive, Suite 206 Beverly Hills, CA 90212 310-277-8855 Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521612 Job Number: 62649 Date: CITY OF LA QUINTA 6/17/2013 BUILDING & SAFETY DEPT. APPROVED FOR CONS F UCTION The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. Th s p gram has approv I and is authorized by the California Energy Commission for use with both the Residential and Non If it 'ng ne y Efficienc tan rds. � DATE This program developed by EnergySoft, LLC — www.energysofi. Energ Pro 5.1 by Energ Soft User Number 8165 RunCode: 2013-06-11T09:47:31 ID: 62649 ,1,ectronipally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/17/2013 ;lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name CORAL MOUNTAIN - PLAN C Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1611712013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,849 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If'Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes '❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity . (ft) Features see Part 2 of 5 Status Wall Wood Framed R-21 3,391 New Wall Wood Framed R-19 149 Ext=R-4.0 New Roof Wood Framed Rafter R-38 2,849 New FENESTRATION Orientation Area(fe) U- ;. Factor SHGC Overhang Sidefins Exterior Shades Status Right (S) 54.6 0.290 0.33 none none Roll -down Blind or Slats New Right (S) �.. , 141.0 0.290r -. 0.29. none .w.... ftnone ,..,..Roll -down Blind or,Slats New Front (140 72.6 0. 0 1' 0.33 .none ' � none Roll -down Blind or Slats New Rear (E) ,,,,"68.4 1 1• 1'0.290 0.33 none 'none _ Roll -down Blind or Slats . New • _ Rear (E) r If" 122.0 I ` a 0.320 0.28 5. none none Roll -down Blind or Slats''' , New 0', Rear (E)*, .. `' 56.4, t_ ` 0.290..+r 0.29 r ` none none , ,. Roll -down Blind or Slatsis f `��, New::A Front (W) 28.2 0.290 0.29 none none Roll -down Blind or Slats New HVAC SYSTEMS Ot . Heating Min. Eff 1' Central Furnace 80% AFUE 1 Central Furnace 80% AFUE 1 Central Furnace 80% AFUE HVAC DISTRIBUTION Location Heating 3.5T Carrier Ducted 2.5T Carrier Ducted 1.5T Carrier Ducted WATER HEATING .,, .,r- 1 Instant Gas Cooling Split Air Conditioner Split Air Conditioner Split Air Conditioner -Coolin Ducted Ducted Ducted Gallons Min. Eff 0 0.84 Min. Eff 15.5 SEER 15.5 SEER 16.0 SEER Duct Location Conditioned Conditioned tr L A /� o-u----I ConditionedjTY OF Q� 6.�0l I BUILDING & SAFETY DEPT. Distribution,.i�` F Kitch rWi e linONSTRUCTION N DATE BY Thermostat Setback Setback Setback Duct R-Value 6.0 Status New New New Status New New New Status New Energ Pro 5.1 by Energ Soft User Number. 8165 RunCode: 2013-06-11T09:47:31 ID: 62649 Page 1 of 7 Reg: 212-N0070417D-000000000-0000 Registration Date/Time: 2012/12/13 18:31:00 HERS Provider: CalCERTS, Inc 71,ectroniFally Filed by Gangyi Zhou and Authenticated at Ca10ERTS.com - 6/17/2013 :lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 PERFORMANCE CERTIFICATE: Residential . (Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN C Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 611712013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency _ determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. ' r s HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater.- The inspector< m 6st receive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling System Bryant 315JAV048090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Bryant 315JAV036070 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. , The HVAC System 2.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field ve�cati6njis r6q �ired QI III �sn .� LA I Tq The HVAC System 2.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Cdndifioned'spacd. YA ceitif—KrtlERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. A h P P Qa /c r' I The HVAC System 2.5T Carrier includes credit for verified adequate airflow. Aertifted-HER ater st diagnostically measur airflow of the HVAC r U EfO�NUCTION I System. The HVAC System 2.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is regyired to verify that duct leakage meets the specified criteria. DATE V I ------- EnerqyPro 5.1 by EnerpySoft User Number: 8165 RunCode: 2013-06-11 T09:47:31 ID: 62649 Page 2 of 7 Reg: 212-N0070417D-000000000-0000 Registration Date/Time: 2012/12/13 18:31:00 HERS Provider: CalCERTS, Inc .1Rctroni�:ally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/17/2013 :lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN C Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/17/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION I Items in this section require field testing and/or verification by a certified HERS Rater °The'inspectormustreceive a completed CF-4R form for each of the measures listed below for final to be given. The Cooling. System Bryant 315JA V036070(1) includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correc(Condenser. The HVAC System 1.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 1.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 1.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 1.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. L JA U U I IN I t-`i DEPT. ;z,AEPTY f '7' 1:)��`SOVED FOH c;ONSTRUG I I N avE . BY- EnerqyPro 5.1 by EnerqySoft User Number: 8165 RunCode: 2013-06-11 T09:47:31 ID: 62649 Page 3 of 7 Reg: 212-N0070417D-000000000-0000 Registration Date/Time: 2012/12/13 18:31:00 HERS Provider: CalCERTS, Inc 7bectronipally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/17/2013 electronically Signed at'Ca10ERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone I Date CORAL MOUNTAIN - PLAN C ❑ Multi Family ❑ Existing+ Addition/Alteration 1611712013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV kBtufft2- r North East South west Space Heating 5.91 4.11 1.81 4.35 1.57 4.10 1.81 3.94 1.98 Space Cooling 72.12 41.34 30.78 40.57 31.55 40.50 31.62 41.60 30.52 Fans 14.45 14.94 -0.49 14.69 -0.23 14.67 -0.22 15.02 -0.57 Domestic Hot Water 12.80 9.12 3.69 9.12 3.69 9.12 3.69 9.12 3.69 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 105.29 69.50 35.79 68.72 36.57 68.38 36.91 69.67 35.62 Percent Better Than Standard: 34.0 % 34.7 % 35.1 % 33.8 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four Orientations Ext. Walls/Roof Wall.Area Area Number of Dwelling Units: 1.00 791 101 Fuel Available at Site: Natural Gas (N)' 919 0 Raised Floor Area: 0 (E) 1,104 147 Slab on Grade Area: 0 (S) 1,170 196 Average Ceiling Height: 1 11.2 Roof Z849 0 Fenestration Average U-Factor: 0.29 TOTAL: 443 Average SHGC: 0.31 Fenestration/CFA Ratio: 15.6 % REMARKS - STATEMENT OF COMPLIANCE This certificate of cornpliance`lists the building features and specifications needed to comply with Title 24, Parts' 1 the Administrative Regulations and Part 6 the Efficiency Standards of th& California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GMEP Engineers 611712613 Address 4400 Campus Drive Name Gangyi Zhou City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone 9497521612 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and -worksheets -,with the specifications, and with any other calculations submitted with this permit -application, d og i% thk,ai Arliance using duct design, a duct sealing, verification of refrigerant charge, insulationtinstal lation�quality..,and�biul�dtngaenvelope sealing require installer testing and certification and field verification by�an,approvedtl�E(R�S rater( t n�•)''1_-.1 ,►iJVE0 Designer or Owner (per Business & Professions{•Code).. t FC] C�;�STF'tUCTION Company POON DESIGN INC Address 315 S. Beverly Drive, Suite 206 Name _ 'I BY City/State/Zip Beverly Hills, CA 90212 Phone310-27-7=8855�- - Signed License # Date EnergyPro 5.1 by EnerqySoft User Number: 8165 RunCode: 2013-06-11T09:47:31 ID: 62649' Page 4 of 7 Reg: 212-N0070417D-000000000-0000 Registration Date/Time: 2012/12/13 18:31:00 HERS Provider: CalCERTS, Inc 'l,ectroni�ally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/17/2013 :lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN C Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 611712013 OPAQUE SURFACE DETAILS Surface Type Area U- I Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Wall 6631 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 497 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Wall 70 0.057 R-19 4.0 None 270 90 New 4.3.1-A5 Conditioned Area Wall 79 0.057 R-19 4.0 None 90 90 New 4.3.1-A5 Conditioned Area Roof 1,041 0.028 R-38 0 0 New 4.2.2-A19 Conditioned Area Wall 256 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 595 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 234 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Wall 294 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Roof 1,250 0.028 R-38 0 0 New 4.2.2-A19 Conditioned Area Wall 283 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 243 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Wall 326 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Roof 558 0.028 1 R-38 0 0 New 4.2.2-A19 Conditioned Area FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGCz Azm Status Glazing Type Location/Comments 1 Window 8.2 0.290 NFRC 0.33 NFRC 180 New Andersen Double Pane Low E(1 Conditioned Area 2 Window 8.2 0.290 NFRC 0.33 NFRC 180 New Andersen Double Pane Low E(1 Conditioned Area 3 Window 8.2 0.290 NFRC 0.33 NFRC 180 New Andersen Double Pane Low E 1 Conditioned Area 4 Window 28.2 0.290 NFRC 0.29 NFRC 180 New Plastpro Low E Conditioned Area 5 Window _ 28.2 0.290 NFRC _, 0.29 NFRC 180 New, _. Plastpro Low E Conditioned Area 6 Window' `, 28.2 0.290 NFRC ,,A 0.29 NFRC 180 New ,; Plastpro Low E J +, Conditioned Area 7 1 Window '28.21 0.290 NFRC 0.29 1 NFRC . 180 New Plastpro Low E = .1 Conditioned Area 8 Window 28,2 7-0.290 NFRC ' 0.29 NFRC 180 New V Plastpro Low E k Conditioned Area - 9 Window 8:2 10.290 NFRC 0.33 NFRC 270 New Andersen Double Pane Low E(1 Conditioned Area, 10 Window .4 f 8.2 a 0.290 NFRC 0.33 NFRC 270 New f ' Andersen Double Pane Low E(1 Conditioned Area - 11 Window r '. 8.2 _0.290 NFRC.. n-0.33 NFRC -'. 270 New Andersen Double Pane Lo"w E(1 Conditioned Area fk 12 Window 8.2 - 0.290 NFRC 0.33 NFRC 90 New Andersen Double Pane Low E(1 Conditioned Area 13 Window 1 8.2 0.290 NFRC 0.33 NFRC 90 New Andersen Double Pane Low E(1 Conditioned Area 14.. Window 8.0 •0.290 NFRC 0.33 NFRC. 90 New Andersen Double Pane Low E(1 Conditioned Area 15 Window 22.0 0.320 NFRC 0.28 NFRC 90 New Andersen Double Pane Low E( Conditioned Area 16 Window 22.0 0.290 NFRC 0.33 NFRC 90 New Andersen Double Pane Low E(1 Conditioned Area (1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value' ' EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin H t ' Wd Len H t LExt RExt Dist Len H t Dist Len H t 1 Roll -down Blind or Slats 0.13 2 Roll -down Blind or Slats 0.13 , 3 Roll -down Blind or Slats 0.13 4 Roll -down Blind or Slats 0.13 5 Roll -down Blind or Slats 0.13 6 Roll -down Blind or Slats 0.13 7 Roll -down Blind or Slats 0.13 8 Roll -down Blind or Slats 0.13 9 Roll -down Blind or Slats 0.13 I r+ t-i'` ,/ I N A J U( IN 1 1' M 10 Roll -down Blind or Slats 0.13 S "` J 4 , �. n, r-r_TV EPT ' 11 Roll -down Blind or Slats 0..13 12 Roll -down Blind or Slats 0.13 + k J W__ i 13 Roll -down Blind or Slats 0.13 ° ��, „r,KIC-M I TI N 14 Roll -down Blind or Slats 0.13 15 Roll -down Blind or Slats 0.13 16 Roll -down Blind or Slats 0.13 EnergyPro 5.1 by EnergySoft User Number: 8165 i RunCode: 2013-06-11 T09:47:31 ID: 62649 Pa e 5 of 7 Reg: 212-N0070417D-000000000-0000 Registration Date/Time: 2012/12/13 18:31:00 HERS Provider: CalCERTS, Inc 71ectroni,cally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/17/2013 electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 CERTIFICATE OF -COMPLIANCE: Residential (Part 4 of 5) .CF-1 R Project Name CORAL MOUNTAIN - PLAN C Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/17/2013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame FENESTRATION SURFACE DETAILS ID' Type Area U-Factor SHGC2 Azm Status Glazing Type Location/Comments 17 Window 28.2 • 0.290 NFRC 0.29 NFRC 90 New Plastpro Low E Conditioned Area 18 Window 22.0 0.290 NFRC 0.33 NFRC 180 New Andersen Double Pane Low E(1 Conditioned Area 19 Window 120.0 0.290 NFRC 0.33 NFRC 270 New Andersen Double Pane Low E 1 Conditioned Area 20 Window 20.0 0.290 NFRC 0.33 NFRC 270 New Andersen Double Pane Low E(1 Conditioned Area 21 Window, 28.2 0.290 NFRC 0.29 NFRC 270 New Plastpro Low E _ Conditioned Area 22 Window' N 22.0 0.290 NFRC ,.r ',-` 0.33 NFRC t.90 New Andersen Double Pane•Low E(1 Conditioned Area 23 Window E 28.2 0.290 NFRC 0.29 NFRC 90 New, ; Plastpro Low E '� Conditioned Area 24 Window 8. Q 'Z 0.290 NFRC - 0.33 NFRC ' - y,of 180 New:. -�^�., Andersen'Double Pane Low E(1 Conditioned Area 25 Window- ,8:0 0.290 NFRC 0.33 NFRC 1� 270 New Andersen Double Pane Low E(1 Conditioned Area,, (1) U- Facto r Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade T e SHGC Window Overhang Left Fin Right Fin H t Wd Len Hcit LExt REA Dist Len H t Dist Len H t 17 Roll -down Blind or Slats 0.13 18 Roll -down Blind or Slats 0.13 19 Roll -down Blind or Slats 0.13 20 Roll -down Blind or Slats 0.13 21 Roll -down Blind or Slats 0.13 22 Roll -down Blind or Slats 0.13 23 Roll -down Blind or Slats. 0.13 24 Roll -down Blind or Slats 0.13 25 Roll -down Blind or Slats 0.13 EnergyPro 5.1 by EnergySoft User Number 8165 RunCode: 2013-06-11 T09:47:31 ID: 62649 Pa e 6 of 7 Reg: 212-N0070417D-000000000-0000 Registration Date/Time: 2012/12/13 18:31:00 HERS Provider: Ca10ERTS, Inc ^lectronically Filed by'Gangyi Zhou and Authenticated at CalCERTS.com - 6/17/2013 :lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN C Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 611712013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area Volume Year Built New Existinq Altered Removed 3.5T Carrier COMMON AREA 1,041 15,615 2.5T Carrier EAST WING 1,250 11,250 1.5T Carrier WEST WING 558 5,022 Totals 1 2,849 0 0 0 HVAC SYSTEMS . System Name Qty.- Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status 3.5T Carrier — ' 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 2.5T Carrier 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 1.5T Carriers 1 _ .Central-Fumace 1-,* : 80% AFUE Split Air Conditioner � •16.0 SEER Setback New r V I L - 'I -� r t, i IT I t 1` -r I 1�_ HVAC DISTRIBUTION- y.r—eDuct System Name Heating Cooling Duct Location R-Value Ducts'r4 Tested? Status 3.5T Carrier a . Ducted Ducted Conditioned 6.0 m New 2.5T Career Ducted Ducted Conditioned 6.0 m New 1.5T Carrier Ducted Ducted Conditioned 6.0 New e ❑ WATER HEATING SYSTEMS ' S stem Name Qt . ' Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status RTG-95DVN 1 Instant Gas Kitchen Pipe Ins 199,900 0 0.84 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 o ,—A c Q U i NTA SAFF§y`s emiNarTe Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum FCITY Outside,i GO ►Bufied,l =♦vr91 n/�TI/'1 1 .. Ijh t.Anv JI I-7VV I �v n� r� ❑ - _ BY • Y EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11 T09:47:31 ID: 62649 Page 7 of 7 Reg: 212-N0070417D-000000000-0000 Registration Date/Time: 2012/12/13 18:31:00 HERS Provider: CalCERTS, Inc MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN C 1611712013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. *§150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. *§150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-B. §1506)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water..systems->15 psif'medtb;tlie requirements of Standards Table �i � � � � � � ��� 123-A. �,.,.r t i � i j .I Y�Cr, 150 ' 3A: Insulation is protected from damage, includingthat due o sUno I ht�moisRti mef maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines��cIDdes a vapor"ryetardanf or is en dosed entirely in conditioned space. , t I r� t'VKi V�ry 150 ' 4: Solar water-heatingsystems and/or collectors are certified b the Solar Rating and Certification Cor oration. DATE _---- BY EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11 T09:47:31 ID: 62649 Page 10 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN C 6/17/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support plafforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 1 50m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal.to 2,500 ft2 or 100 watts-for=dwelling units larger than 2,500 ft2 may be ,�,A 1XtiaX N y, exempt from the 50%high efficacy requirement when: all low efficacy luminaires in)- k�tehenar,,controlled * a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene -programmable controI-systetrn;_anq-all Fpermanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet; and utility rooms are high efficacy and controlled by a manual -on occupant sensor. ,- r l ('�� I §150(k)9: Permanently installed lighting that is internal to cabinets shall use -, CAI 20�wa�sr o�pQ;wer p& linear foot of illuminated cabinet. , DATE : -_ BY EnergyPro 5.1 by EnergySoft User Number. 8165 RunCode: 2013-06-11 T09:47:31 ID: 62649 Page 11 of 16 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN C 6/17/2013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they. are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. � �� QUIN PA t=, ' .�F PT 8. SAFEN DE CONSTRUCTION 1 i r,. _E EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11 T09:47:31 ID: 62649 Page 12 of 16 2013 CARP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN C 611712013 • ANNUAL TDV ENERGY USE kl3tu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Margin Margin Standard % Better* Space Heating 5.91 4.11 1.81 35.79 / 105.29 Space Cooling 72.12 41.34 30.78 Cooling Standard Heat Rejection 0.00 0.00 0.00 30.78 Indoor Fans 14.45 14.94 -0.49 Incentive Eligibility Yes No Domestic Hot Water 12.80 9.12 3.69 Owner Incentive (> 15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (> 30%) m ❑ Conditioned Floor Area = 2,849.0 ft2 TOTALS: 105.29 69.50 35.79 Number of Bedrooms = 3 Energy Star V3 Target = 20 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing North Peak Demand kW 9.2 6.1 1 3.1 Standard Proposed Margin ENERGY COMPONENT Electricity Natural as Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 105.32 0.00 73.23 0.00 32.09 Space Cooling 9,239.34 0.00 5,158.54 0.00 4,080.80 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 2,026.23 0.00 2,021.18 0.00 5.05 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 11,265,57 350.65 7,179.72 247.56 4.085.86 103.09 - • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from step 2) Rate from Ste 3 Subtotal Electricity (kWh) 34.0 % �� o.ss X1 4,085.86 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) x 3.1 = $527 NOT GUARANTEED. Projects must meet all other program $/kW kw Natural Gas 34.0 / 3.89 x 103.09 �� - $401 requirements to qualify. Potential incentives are $/therm them, subject to program limitations J2013 Code Preparation = $o Pacific Gas and Electric Company LA QU I N -r�NSHP Tier II = $o c I DE T SOUTHERN CALIFORNIA A4-" BUILDING & S/'`�EN Total E D I S O N' Al --)PROVED Ince live rate is capped at the 45% level An !il)ISUC`' M'TF.H�\N'l%U;\'Al,• Company FOR CONSTRUCTION SDGE A Sempra Energy utirty' D C vdvan�d �0�STM CGas ompany A f7 Sempra Energy vtmty- v EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11T09:47:31 0: 62649 Page 13 of 16 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN C 6/17/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard % Better* Space Heating 5.91 4.35 1.57 36.57 / 105.29 = 34.7 % Space Cooling 72.12 40.57 31.55 Cooling Standard Heat Rejection 0.00 0.00 0.00 31.55 Indoor Fans 14.45 14.69 -0.23 Incentive Eligibility Yes No Domestic Hot Water 12.80 9.12 3.69 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) m ❑ Conditioned Floor Area = 2,849.0 fta TOTALS: 105.29 68.72 36.57 Number of Bedrooms = 3 Energy Star V3 Target = 20 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing East Peak Demand kW 9.2 1 5.93.2 Standard Proposed Margin ENERGY COMPONENT Electricity Natural as Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 105.32 0.00 77.53 0.00 27.78 Space Cooling 9,239.34 0.00 5,055.19 0.00 4,184.16 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 2,026.23 0.00 1,988.84 0.00 37.39 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 11,265.57 350.65 7,044.03 251.87 4,221.55 1 98.79 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available from step 2� Ratebtotal � from Ste 3 Su only through the California Electricity (kWh) 34.7 /0 1.00 x 4,221.55 Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) 34.7 % �' 174 X1 3.2 = $557 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 34.7 % ��' 3.97 x 98.79 = $392 requirements to qualify. Potential incentives are $/therm therm subject to program limitations 2013 Code Preparation = $o Pacific Gas and Electric Company i NSH Tier 11 = $o CITY OF Lr/-\ QUINTA �V SOUTHERN CALIFORNIA ED I S O N' BUILDING & SAFETY DEPotal Incentive rate is capped at the 45% level t wED An EDISON IP7I:RNA770NA1.• Company I.STRUCTION Gp FOR A A�Sempra Energy curry` �firThe C 05 1 � 0 advan�t.:-J h (D m�sTM CGas ompany 1 A Sempra Energy uurty- v A EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11 TO9:47:31 ID: 62649 Page 14 of 16 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN C 611712013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard % Better* Space Heating 5.91 4.10 1.81 36.91 / 105.29 = 35.1 Space Cooling 72.12 40.50 31.62 Cooling Standard Heat Rejection 0.00 0.00 0.00 31.62 / 72.12 = 43.8 Indoor Fans 14.45 14.67 0.22 Incentive Eligibility Yes No Domestic Hot Water 12.80 9.12 3.69 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) m ❑ Conditioned Floor Area = 2,849.0 ftz TOTALS: 105.29 68.38 36.91 Number of Bedrooms = 3 Energy Star V3 Target = 20 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing South Peak Demand kW 9.2 1 5.7 1 3.4 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 105.32 0.00 73.12 0.00 32.19 Space Cooling 9,239.34 0.00 5,129.46 0.00 4,109.88 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 2,026.23 0.00 2,012.93 0.00 13.30 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 11, 265.57 350.65 7,142.39 247.46 4,123.19 103.19 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available from step 2) Rate from Step 3 Subtotal only through the California Electricity (kWh) 35.1 % �' 1.01 X1 4,123.19 J = $4,164 Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) 35.1 % �> 176 x 3.4 = $598 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 35.1 % �' x = requirements to qualify. 4.01 103.19 $414 Potential incentives are $/therm them, subject to program limitations 2013 Code Preparation = $o Pacific Gas and Electric Company NSHP Tier II = $o SOUTHERN CALIFORNIA CITy OF LA QUINTA CITyI $5,17s ED I S O N ' _ DEPTot Inceniive rate is capped at the 45% level BUILDING An EINSOh 1WER,NA 7 NAL* Company sgi r \9 1 ROVED ION FOR ' A *Sempra Energy utlrty* C ' The Gas TM advircancehomes Company A (4)Sempra Energy mnay- EnergyPro 5.1.7.1 by EnergySoft User Number- 8165 RunCode: 2013-06-11T09:47:31 /D: 62649 Page 15 of 16 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN C 6/17/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard % Better* Space Heating 5.91 3.94 1.98 35.62 / 105.29 = 33.8 Space Cooling 72.12 41.60 30.52 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 30.52 Indoor Fans 14.45 15.02 -0.57 Incentive Eligibility Yes No Domestic Hot Water 12.80 9.12 3.69 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) m ❑ Conditioned Floor Area = 2,849.0 ft2 TOTALS: 105.29 69.67 35.62 Number of Bedrooms = 3 Energy Star V3 Target = 20 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing West Peak Demand kW 9.2 5.s 3.3 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 105.32 0.00 70.18 0.00 35.13 Space Cooling 9,239.34 0.00 5,281.54 0.00 3,957.80 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 2,026.23 0.00 2,061.56 0.00 -35.33 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.001 0.00 0.00 0.00 0.00 TOTALS: 11,265.57 350.65 7,343.11 244.52 1 3,922.47 106.14 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available only through the California from step 2) Rate from Step 3 Subtotal Electricity (kWh) 33.8 % 0.97 X 3,922.47 = $3,805 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 33.8 % �' 169 x 3.31 = $558 NOT GUARANTEED. Projects must meet all other program $/� kw Natural Gas 33.8 /0 x requirements to qualify. 3.86 106.14 $410 Potential incentives are $/them, them, subject to program limitations 2013 Code Preparation = $o Gas and rPacific Electric Company NSHP Tier II $o = 0 SOUTHERN CALIFORNIA kITN 1 A Q I )tatI �� _ $4,773 V1 ED I S O N* ©� %� " ( S��EN [Ijtce�trve'r.t is capped at the 45% level '.DIN( & An EUISON M'l'fiHNATfU,VAI.• Company �E � R +--y�O VE� -o Cp UCTION i P�p A �Sempra Energy malty* BY. The Gas Ma '57 adv Ce �omesrrn Company A t Sempra Energy uurry- EnergyPro 5.1.7.1 by EnergySoft User Number. 8165 RunCode: 2013-06-11TO9:47:31 ID: 62649 Page 16 of 16 BUILDING ENERGY ANALYSIS REPORT PROJECT: CORAL MOUNTAIN - PLAN D LA QUINTA, CA Project Designer: POON DESIGN INC '315 S. Beverly Drive, Suite 206 Beverly Hills, CA 90212 - 310-277-8855 - Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521612 0 Job Number: UINTA OF 62649 DEPT. �?DILDi'�`NG & SA .DP VED �iVED ON Date: FOR CONSTRUCT 6/1013 1 CA_f �— BY 7/2 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 5.1 by Energ Soft User Number. 8165 RunCode: 2013-06-11T10:21:59 ID: 62649 TABLE OF CONTENTS Cover Page Table of Contents Form CF-1 R Certificate of Compliance Form MF-1 R Mandatory Measures Summary Form UTIL-1 R Utility Incentive Worksheet 11 a CI- - �� L (��J1�1TA DEPT. F�ll,ll: D1M &SAFE ® FOR ONSTTR CT10N FOR C O?ATE BY 1 2 3 9 12 L nergyPro 5.1 by EnergySoft Job Number: ID: 62649 User Number: 8165 ^lectroni,cally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/17/2013 :lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 i PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name CORAL MOUNTAIN - PLAN D Building Type m Single Family ❑ Addition Alone I ❑ Multi Family ❑ Existing+ Addition/Alteration Date 611712013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,814 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) , Features see Part 2 of 5 Status Wall Wood Framed R-21 2,102 New Roof Wood Framed Rafter R-38 2,814 New FENESTRATION i U- Exterior Orientation Area(fe) I Factor SHGC Overhang Sidefins Shades Status Front (N) 44.0 ' 0.300 0.29 none none Roll -down Blind or Slats New Left(E) 70.5 0.290,to�,0.29. .noneA4 none Bug Screen New Right (W)O' y V 19.0 , r 0:290 1f 0.33 none4 none f. Roll -down Blind or Slats New Right (W) "53.3 1 / . 0.290 0.29 none � = tnone � Bug Screen % -New Front (N) f 42.3 !' F 4� 0.290 0 29 none none � Bug Screen" r'`r:' ; a New Left(E)ti. r ""i'e22.6f �0.3001' =v0.29 -none enone ,.'- Roll -down Blind orSlatsNew Rear (S) 66.0 t 0.320 0.28 none none Roll -down Blind or Slats New z t I - HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Coolin Duct Location��_p_` R-Value Status 3.5T Carrier Ducted DuctedGCo ditionedAF�N Utz 6.0 . New, 3.5T Carrier Ducted � Ducted BUiLUConaS�yv!diti ne,dn\I F— t) 6.0 New htgTRUCTIO WATER HEATING Qty. Type Gallons Min. Eff Distri •,uti.oStatus 1 Instant Gas 0 0.8Een-Pip'ieIns New EnergyPro 5.1 by Energ Soft User Number: 8165 RunCode: 2013-06-11 T10:21:59 ID: 62649 Page 1 of 6 Reg: 212-N0070418E-000000000-0000 Registration Date/Time: 2012/12/13 18:31:34 HERS Provider: CalCERTS, Inc 33ectroni,cally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/17/2013 electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5)` CF-1 R Project Name CORAL MOUNTAIN - PLAN D Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/17/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. - Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. 1 ' HERS REQUIRED VERIFICATION Items ih this section require field testing and/or verification by a certified HERS Rater. - The 'inspector.must receive a completed CF-413 form for each of the measures listed below for final to be given. The Cooling System Bryant 315JAV048090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. l The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. •ti Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Bryant 315JAV048090 includes credit for a 13.0 EER Cow nddeen6ser A-certified"H� ��rater • ust field verify the installation of the correct Condenser. (-"'",.� e' f"l A The HVAC System 3.5T Carrier incorporates HERS Verified Refrige'rant�Cha�gd or. a ChargedndicatopDispla� I BUILDING 6 �- Compliance credit for quality installation of insulation has been used.§ HERS field Vdhfiadtioriirequired= 14 .. ,� r•nt.R 'TRUCTION The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit loca ea0b ally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. 1 _ The HVAC System 3.5T Carrier includes credit for verified adequate airflow. qcertified HERS ra er-must-diagnostically measure airflow of the HVAC System. I DATE---` The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage" 'RERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro 5.1 by EnerqySoft User Number: 8165 RunCode: 2013-06-11T10:21:59 ID: 62649 Pa e 2 of 6 Reg: 212-N0070418E-000000000-0000 Registration Date/Time: 2012/12/13 18:31:34 HERS Provider: CalCERTS, Inc 71ectroni,cally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/17/2013 'lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 PERFORMANCE CERTIFICATE: Residential . (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date CORAL MOUNTAIN - PLAN D ❑ Multi Family ❑ Existing+ Addition/Alteration 611712013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV kBtu/ft2- r North East South - west Space Heating 3.48 2.11 1.38 1.93 1.55 2.00 1.48 2.17 1.31 Space Cooling 58.42 36.44 21.98 36.55 - 21.87 37.04 21.37 36.11 22.31 Fans 11.69 13.29 -1.60 13.32 -1.64 13.49 -1.80 13.18 -1.49 Domestic Hot Water 12.96 9.23 3.73 9.23 3.73 9.23 3.73 9.23 3.73 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 86.55 61.06 25.49 61.03 25.52 61.76 24.79 60.69 25.86 Percent Better Than Standard: 29.4 % 29.5 % *28.6 % 29.9 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four Orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 759 86 Fuel Available at Site: Natural Gas (E) 682 93 Raised Floor Area: 0 (S) 611 66 Slab on Grade Area: 0 r (tM 367 72 Average Ceiling Height: 11.1 Roof Z814 0 Fenestration Average U-Factor: 0•30 TOTAL: 317 Average SHGC: 0.29 Fenestration/CFA Ratio: 11.3 % REMARKS--. #, STATEMENT OF COMPLIANCE ' This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GMEP Engineers 6/17/2013 Address 4400 Campus Drive Name Gangyi Zhou Cit /S ate/Zip Newport Beach, CA 92660 Phone 949752161� e • Date The individual with overall design responsibility hereby eerti�fiees thOt� the-prropo sed binding design represented in this set of construction documents is consistent with the other co��pppliance-fog##) A, Ork�s,�heets, With the specifications, and cit.►1l 1JIkrU with any other calculations submitted with this permit. application., and-recogni es that comp ance using duct design, `� �. . li. y .. �- duct sealing, verification of refrigerant charge, insulab'on installaf�on qq� lily-a�n b i it ibg en elope sealing require installer testing and certification and field verification y an 4m ove0h,E S rater. Designer or Owner (per Business & Profes ions Code) BY Company POON DESIGN INC DATE ---�� Address 315 S. Beverly Drive, Suite 206 Name City/State/Zip Beverly Hills, CA 90212 Phone 310-277-8855 Signed License # Date EnenqvPro 5.1 by EnerqySoft User Number: 8165 RunCode: 2013-06-11T10:21:59 ID: 62649 Pa e 3 of 6 Reg: 212-N0070418E-000000000-0000 Registration Date/Time: 2012/12/13 18:31:34 , HERS Provider: CalCERTS, Inc ^lectroni,cally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/17/2013 electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN D Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration IDate 611712013 OPAQUE SURFACE DETAILS Surface Type Area Ll- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Wall 3281 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 245 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 294 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Roof 1,512 0.029 R-38 01 0 New 4.2.2-A18 Conditioned Area Wall 345 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 345 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 545 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Roof 1,302 0.029 R-38 0 0 New 4.2.2-A18 Conditioned Area FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 22.0 0.300 NFRC 0.29 NFRC 0 New Andersen Double Pane Low E(1 Conditioned Area 2, Window 22.0 0.300 NFRC 0.29 NFRC 0 New Andersen Double Pane Low E(1 Conditioned Area 3 Window 14.1 0.290 NFRC 0.29 NFRC 90 New Plastpro Low E Conditioned Area 4 Window 14.1 0.290 NFRC 0.29 NFRC 90 New Plastpro Low E Conditioned Area 5 Window Y 14.1 0.290 NFRC_. 10.29 NFRC 90 New _ Plastpro Low E Conditioned Area 6 Window: N/ 7.0 0.290 NFRC 0.33 NFRC w `270 New Andersen Double Pane'Low E(2 Conditioned Area 7 Window 6.0 0.290 NFRC 0.33 'NFRC 270 New . Andersen, Double Pane Low E(2 Conditioned Area 8 Window 6.0 Z 0.290 NFRC 0.33 NFRC . f 270 New Andersen'Double Pane Low E(2 Conditioned Area 9 Window 32.0 10.290 NFRC 0.29 NFRC 270 New a Plastpro'Low E N ti. Conditioned Area.. !� 10 Window .4 1 7. 1, 0.290 NFRC 0.29 NFRC f270 New Plastpro Low E .I Conditioned Area ' 11 1 Windowme r t - 7.1 0.290 NFRC -0.29 NFRC -270 New �, Plastpro Low E i,- -4e- Conditioned Area t"'a. 12 Window 7.1 0.290 NFRC 0.29 NFRC 270 New Plastpro Low E ' Conditioned Area 13 Window 28.2 0.290 NFRC 0.29 NFRC 0 New Plastpro Low E Conditioned Area 14.. Window '14.1 0.290 NFRC 0.29 NFRC 0 New Plastpro Low E Conditioned Area 15 Window 22.0 0.300 NFRC 0.29 NFRC 90 New Andersen Double Pane Low E(1 Conditioned Area 16 Window 28.2 0.290 NFRC 0.29 NFRC 90 New Plastpro Low E Conditioned Area (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID 'Exterior Shade Type SHGC Window Overhang Left Fin Right Fin H t Wd Len. H t LExt RExt Dist Len H t Dist Len H t 1 Roll -down Blind or Slats 0.13 2 Roll -down Blind or Slats 0.13 3 Bug Screen 0.76 4 Bug Screen 0.76 5 lBug Screen 0.76 - 6 Roll -down Blind or Slats 0.13 7 Roll -down Blind or Slats 0.13 ("1 Y (-It- U" ^r 8 Roll -down Blind or Slats 0.13 1 ' 9 BugScreen 0.76 "" ` Ry�-a f /C Sri 10 BugScreen 0.76 �� 'L ) V L - 11 Bug Screen 0.76 - (� ; NS I t 12 Bug Screen 0.76 13 Bug Screen 0.76 j 14 Bug Screen 0.76 ) n n F 15 Roll -down Blind or Slats 0.13 16 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11T10:21:59 ID: 62649 Pa e 4 of 6 Reg: 212-N0070418E-000000000-0000 Registration Date/Time: 2012/12/13 18:31:34 HERS Provider: CalCERTS, Inc -7lectronigally Filed by Gangyi Zhou and Authenticated at Ca10ERTS.com - 6/17/2013 :lectronically Siqned at CalCERTS.com by Russell. Jones (Alta Verde Builders) 6/17/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN D Building Type m Single Family ❑ Addition Alone ❑ Multi Family ' ❑ Existing+ Addition/Alteration Date 611712013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavit Exterior Frame Interior Frame ( FENESTRATION SURFACE DETAILS ID Type Area . U-Factor SHGCz Azm Status Glazing Type Location/Comments 17 Window 22.0 0.320 NFRC 0.28 NFRC 180 New Andersen Double Pane Low E(3 Conditioned Area 18 Window 22.0 0.320 NFRC 0.28 NFRC 180 New Andersen Double Pane Low E(3 Conditioned Area 19 Window 22.0 0.320 NFRC 0.28 NFRC 180 New Andersen Double Pane Low E( Conditioned Area (1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 17 Roll -down Blind or Slats 0.13 18 Roll -down Blind or Slats 0.13 19 Roll -down Blind or Slats 0.13 I r l 111 ninir° A SAFE I Y uCr 1I I �V1L v•• •• aR"�t�� /irr I • I / -� Imo' I� � I�� �' �- �-�• 1 I cn STIiU t ivy l - EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11T10:21:59 ID: 62649 Page 5 of 6 Reg: 212-NO07041BE-000000000-0000 Registration Date/Time: 2012/12/13 18:31:34 HERS Provider: CalCERTS, Inc ;lectroni,cally Filed by Gangyi Zhou and Authenticated at CalCERTS;com - 6/17/2013 :lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN D Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 611712013 BUILDING ZONE INFORMATION System Name . Zone Name Floor Area Volume Year Built New Existinq Altered Removed 3.5T Carrier COMMON AREA 1,512 19,656 3.5T Carrier Bedrooms 1,302 11,718 Totals Z814 0 0 0 HVAC SYSTEMS +; _System Name Qty. Heating Type Min. Eff. " Cooling Type Min. Eff. Thermostat Type Status 3.5T Carrier - 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 3.5T Carrier 1 ' Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New Ile I M. HVAC DISTRIBUTION ¢ .J /' 1. .a ! rf _ C — " is i `.,1 System Name Heating Cooling I-, Duct Location ``''Duct ,L . R-Value Gr Ducts='k'< Tested? Status 3.5T Carrier - Ducted Ducted Conditioned 6.0 m New 3.5T Carrier Ducted Ducted Conditioned 6.0 m New ' ❑ WATER HEATING SYSTEMS S stem Name Qt . T e - Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status RTG-95DVN 1 Instant Gas Kitchen Pipe Ins 199,900 0 0.84 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HE)ATINGISYSTEM PIPING Control Hot Water Piping Length'• ff ` F 1 Si Aga \ (A. Q d • �"v 311<1Cx & SAFETY DEW �,O_ VE®. T. )f{ C;UNS fFtUCTlO System Name ► - Pipe Len ",ih Pipe Diameter Insul. Thick. Qty. HP Plenum Outside. 1 Buried { ❑ _�— — EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11T10:21:59 ID: 62649 Pa e 6 of 6 r • Reg: 212-N0070418E-000000000-0000 Registration Date/Time: 2012/12/13 18:31:34 HERS Provider: CalCERTS, Inc MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R L7611712013 Project Name CORAL MOUNTAIN - PLAN D Date NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk.(*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to waterlheater't_an n{ir' on=recircu a it ng systems, an entire length of recirculatin sections of hot water pipes are insulated per Standards,Table�1�50 BF LA UU i iN i §1500)2: Cooling system piping (suction, chilled water, or brine lines) and pipintig-id nsulateg: twde"n)'he'3iing source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-AN §1500)2: Pipe insulation for steam hydronic heating systems or h"ot watertdms"31'5'psi,' m' 66ts=tfie requirements of Standards Table 123-A. F R 6ONSTRUCTIQ111 150 ' 3A: Insulation is protected from damage, including that du: to sunlight, moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapoBr retardant or is enclosed entirely in conditioned space. DATE 150 ' 4: Solar water -heating systems and/or collectors are certified`b fhe So ar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11T10:21:59 ID: 62649 Page 9 of iLi MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN D 611712013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings heater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Hea ting Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150 k 7: All switching devices and controls shall meet the requirements of._ 150 k 7 §150(k)8: A minimum of 50 percent of the total rated wattage of Vermanently installed lighting in" k tchens,sHall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to(2;500 ftz o A 60 watts ford ellin its ar er than 2,500 ftz may be exempt from the 50% high efficacy requirement when: all low efficac lgminalreszinSthe�kitche�nare�con rolled b a manual on occupant � Y P a �Y�., r N sensor, dimmer, energy management system (EMCS), or a multia scene progYram�rnable con�ttokl4 s em; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet�amd utility rooms are hig efficac and controlled by a 1 manual -on occupant sensor. FOR CONS 1 �iLyU � §150(k)9: Permanently installed lighting that is internal to cabinet shall use no more than 20 watts of power�per linear foot of illuminated cabinet. _ 1 OA\TE — ---- ---- EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11 T10:21:59 ID: 62649 Page 10 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN D 1611712013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms; closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain.a screw -base socket, and consume no more than five watts of power as determined according to 130 d . §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. GI1-Y OF LA QUINTA & SAFETY PT. BUILDING � E A FOR CpROV ION DATE ._----- BY EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11T10:21:59 ID: 62649 Page 11 of 15 2013 CARP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN D 6/17/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r - • PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard % Better* Space Heating 3.48 2.11 1.38 25.49 / 86.55 = 29.4 Space Cooling 58.42 36.44 21.98 Cooling Standard Heat Rejection 0.00 0.00 0.00 21.98 / 58.42 Indoor Fans 11.69 13.29 -1.60 Incentive Eligibility Yes No Domestic Hot Water 12.96 9.23 3.73 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) ❑ m Conditioned Floor Area = 2,814.0 ft2 TOTALS: 86.55 61.06 25.49 Number of Bedrooms = 4 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing North Peak Demand kW 7.5 5.1 2.4 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 61.391 0.00 37.181 0.00 24.21 Space Cooling 7,239.95 0.00 4,572.10 0.00 2,667.85 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,583.63 0.00 1,783.97 0.00-200.34 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.001 0.00 0.00 0.00 0.00 TOTALS: 8,823.58 306.73 1 6,356.07 211.52 2,467.51 95.21 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available from step 2) Rate from Ste 3 Subtotal only through the California Electricity (kWh) 2s.4 % �' 0.84 xi 2,467.51 Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) 2s.4 % �� 147 x NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 2s.4 % �� 3.36 X1 95.21 = $320 requirements to qualify. Potential incentives are $/them, them, subject to program limitations 2013 Code Preparation = $o Pacific Gas and • Electric Company NSHP Tier I I = $o CITY OF IJ6, (QUIUTA �VY SOUTHERN CALIFORNIA t I ET T DEOT al.,1LD�lG �` St-�r Total $2,746 E D I SO N' PP - --3 ,D0 J E D Incentive rate is capped at the 45% level � ) b :ter An EDISON INTERNATIONAL* Company 1,.. tiSTRUCTiON FUG{ SDGE A A,Sempra Energy utility' Cd The a vncn`.J h Ob Company t�.J�:r.J95TM .�J A � • Sempra Energy uuny- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11 T10:21:59 ID: 62649 Page 12 of 15 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN D 6/17/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Margin Margin Standard %Better* Space Heating 3.48 1.93 1.55 25.52 Space Cooling 58.42 36.55 21.87 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 21.87 / 58.42 = 37.4 Indoor Fans 11.69 13.32 1.64 Incentive Eligibility Yes No Domestic Hot Water 12.96 9.23 3.73 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) ❑ m Conditioned Floor Area = 2,814.0 ftz TOTALS: 86.55 61.03 25.52 Number of Bedrooms = 4 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing East Peak Demand kW 7.5 5.1 1 2.4 1 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 61.39 0.00 34.12 0.00 27.27 Space Cooling 7,239.95 0.00 4,611.01 0.00 2,628.94 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,583.63 0.00 1,795.03 0.00-211.39 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.001 0.00 TOTALS: 8,823.58 306.73 1 6,406.03 208.46 2A17.55 98.27 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available from step 2) Rate from Ste 3 Subtotal = only through the California Electricity (kWh) 2s.5 % 0.85 X1 2,417.55 $2,055 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 29.5 % �� 148 X1 2.4 = $355 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 2s.5 % �> 3.37 X1 98.27 = $331 requirements to qualify. Potential incentives are $/therm them, subject to program limitations 2013 Code Preparation = $o [7fl Pacific Gas and Electric Company CITY OF QL]INNSHP Tier II = $o & SAFETY DEPT. BUILDING V SOUTHERN cALIFORNIA Total = $2,741 EDISON° 0PP UC + FOR CONSTRUCTIONIn�entiv rate is capped at the 45% level An !;DlSOn' 1A'7'1iRA1A770oVAL• Company 1 SOLE I DATE A �Sempra Energy uuriryg Q j� or ca Gas ��JTA1 advanond hoThe Company D A Sempra Energy °uiay- v EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11T10:21:59 /D: 62649 Page 13 of 15 2013 CA UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN D 6/17/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard % Better* Space Heating 3.48 2.00 1.48 24.79 / 86.55 = 28.6 % Space Cooling 58.42 37.04 21.37 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 21.37 / 58.42 = 36.6 Indoor Fans 11.69 13.491 -1.801 Incentive Eligibility Yes No Domestic Hot Water 12.96 9.23 3.73 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) ❑ m Conditioned Floor Area = 2,814.0 ft-- TOTALS: 86.55 61.76 24.79 Number of Bedrooms = 4 Energy Star V3 Target = 15 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing South Peak Demand kW 7.5 5.3 1 2.2 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 61.39 0.00 35.41 0.00 25.98 Space Cooling 7,239.95 0.00 4,631.83 0.00 2,608.12 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,583.63 0.00 1,802.68 0.00-219.04 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.001 0.00 0.00 TOTALS: 8,823.58 306.73 1 6,434.51 1 209.74 1 2,389.08 96.99 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available from ste 2) Rate from Ste 3 Subtotal only through the California Electricity (kWh) X1 2,389.08 Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) zs.s % .......143 x NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 28.6 % �� 3.27 x 96.99 = $317 requirements to qualify. Potential incentives are $ahem, therm subject to program limitations 2013 Code Preparation = $o Pacific Gas and Electric Company NSHP Tier 11 = $o QU I T SOUTHERN CALIFORNIA rl E D I S O N* C.1 1 Y OF t _A Ota SAFEN �E' lncenti is the 45% level E111L€�iNO & a rate capped at An BINSON INTERNA770N.40 Company � 1T �///7^) SDGE tit � FOI' �i TION �■�° A Sempra Energy uerty' The Cal TM advanced homes CGas ompany A �j��'Sempra Energy mniry- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11 T10:21:59 ID: 62649 Page 14 of 15 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN D 6/17/2013 • ANNUAL TDV ENERGY USE k13tu/sgft- r - • PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard % Better* Space Heating 3.48 2.17 1.31 25.86 Space Cooling 58.42 36.11 22.31 Cooling Standard Heat Rejection 0.00 0.00 0.00 22.31 / 58.42 = 38.2 Indoor Fans 11.69 13.18 1.49 Incentive Eligibility Yes No Domestic Hot Water 12.96 9.23 3.73 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) ❑ m Conditioned Floor Area = 2,814.0 ft2 TOTALS: 86.55 60.69 25.86 Number of Bedrooms = 4 Energy Star V3 Target = 15 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing West Peak Demand kW 7.5 5.2 12.3 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 61.39 0.00 38.40 0.00 23.00 Space Cooling 7,239.95 0.00 4,480.46 0.00 2,759.49 0.00 Heat Rejection 0.00 0.00 0.00 0.00. 0.00 0.00 Indoor Fans 1,583.63 0.00 1,752.91 0.00-169.28 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 8,823.58 306.73 6,233.37 212.73 2,590.21 94.00 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available from step ° 2� Ratebtotal � from Ste 3 Su =1 only through the California Electricity (kWh) 2s.s o.8s X1 2,590.21 $2,228 Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) 2s.s % �� 15o X1 2.3 = $345 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 2s.s % �' 3.42 X1 94.00 = $321 requirements to qualify. Potential incentives are $/them, them, subject to program limitations 2013 Code Preparation = $o Pacific Gas and Electric Company NSHP Tier II = $o CITY OF LA QUINTA SOUTHERN CALIFORNIA BUILDING & SAFETY DEPTTotal E D I S O N' *L PPRO\ /ED IncAntive rate is capped at the 45% level APPROVED An F,D,SOA Company FOR C .RUCTION DA !±4 A Sempra Energy uufiy' he Gas TM A homnos advanor's---.1 Company A �Sempra Energy utiiny- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11 T10:21:59 ID: 62649 Page 15 of 15 BUILDING ENERGY ANALYSIS REPORT PROJECT: CORAL MOUNTAIN - PLAN J LA QUINTA, CA Project Designer: POON DESIGN INC 315 S. Beverly Drive, Suite 206 Beverly Hills, CA 90212 310-277-8855 Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521612 Job Number: b bC;yTY OF LA QUINTA BUILDING & SAFETY DEPT. Date: APPROVED q 1/2 /2013GR CONSTRUCTION DATE BY The EnergyPro computer program has been used to perform the calculations'suimmarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program. developed by EnergySoft, LLC — www.energysoft.com. Energy -Pro 5.1 by Energ Soft User Number. 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 i ' TABLE -OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary 9 Form UTIL-1 R Utility Incentive Worksheet 12 OF LA QUINTA GUIL.DiNG & SAFETY DEPT. PUP) ROVED FO('-i CONSTRUCTION r� Tr BY EnergyPro 5.1 by Energysoft Job Number: ID: 62649 User Number: 8165 .1'ectronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 ;lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5) -CF-1 R Project Name CORAL MOUNTAIN - PLAN J Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 Project Address LA QUINTA California Energy Climate Zone I CA Climate Zone 15 Total Cond. Floor Area 2,668 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST - ❑ Yes O No HERS Measures --If Yes, A CF-4R must be provided per Part 2 of 5.of this form. ❑ Yes ❑ No Special Features --If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Wall Wood Framed R-21 3,093 New Roof Wood Framed Rafter R-38 2,668 New FENESTRATION U- Orientation Area(ft) , Factor Exterior SHGC Overhang Sidefins Shades " Status Right (N) 44.0 { 0.300 0.29 none none Roll -down Blind or Slats New Right (N) 16.0 t 0.290�0,33.,, none none p��Roll-down,Bfind or,Slats New Right (N) ,f 56.4. ,0:290' 0.29 none' F: none: Bug Screenf New Left (S)r ,,0'16.0 %il 10.290 0.33 • 'none - ,--4one' Roll-dow'n Blind or Slats. -New -. _ Front (E) 33.0 �` 0.290 0�33 - ' none, - none .* Roll -down Blind o� Slats C".r ;�N, ,New 0 Front (E) 84. 6 ;, ' 0.290 6.29 = : nonee. » •< -,none r ' f F Bug Screen l - ! 'New Reai (W) 28.0 1 0.280 0.28 none none Roll -down Blind or Slats New Rear (W) `'. t _ 24.0 0.290 0.33 none none Roll -down Blind or Slats New Front (E) 22.0 ; 0.320 0.28 none none Roll -down Blind or Slats New Left (S) 44.0 0.320 0.28 none none Roll -down Blind or Slats New f HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 1 Central Furnace 80% AFUE . Split Air Conditioner 15.5 SEER Setback New. HVAC DISTRIBUTION Location Heating Duct Cooling Duct_Lo.c._ , ^,� ,,,ation =Value Status 3.5T Carrier Ducted Ducted (rondjbofieOF Llk UU t'.4 tl 2.0 1 New 3.5TCarrier Ducted Ducted Lggj(1(tiR)edlG &'SAI-I-zf I v'L__ 6.0 New I P ROV I WATER HEATING � FOR CONS] Qty. Type Gallons Min. Eff Distribution Status 1 Instant Gas 0 0.84 oATE Kitc Pipe-InLy New Energ Pro 5.1 by Energ Soft User Number: 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 1 of 6 Reg: 212-N0070419C-000000000-0000 Registration Date/Time: 2012/12/13 18:31:56 HERS Provider: CalCERTS, Inc 71'ectronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 ;lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential .(Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN J Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013' SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. r• r° I f f, �i�1 1 ' •i. ��J Cs HERS, REQUIRED YERIFICATION Items in,this section require field testing and/or verification by a"certified HER Rater. The inspectorxmust recewe a completed CF-4R form for each of the measures listed below for final to be given. The Cooling, System Bryant 315JAV048090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. _ The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Bryant 315JA V048090 includes credit for a 13.0 EER Condenser. A certified HERS rater ---t.field-verify the -installation of the correct Condenser. n t-T-\7 1✓ t A (lid 11NITA The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or'a Charge" In'dicatdr"Display." — I BUILDING & SAFETY DEPT. Compliance credit for quality installation of insulation has been used. HERS field verification is required. ROVED pp�iq-rQl i TI The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally within onndi'tib e s ace. A certified HERS ter must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagg?stically measure ai j w of the HVAC System. DA 1 t _--- The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field veri nation and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro 5.1 by Ener Soft User Number: 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 2 of 6 Reg: 212-N0070419C-000000000-0000 Registration Date/Time: 2012/12/13 18:31:56 HERS Provider: CalCERTS, Inc ^lectroni,cally,Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 3lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date CORAL MOUNTAIN - PLAN J ❑ Multi Family ❑ Existing+ Addition/Alteration 11312013 ANNUAL ENERGY USE SUMMARY . Standard Facing Margin Facing Margin Facing. Margin Facing Margin TDV kBtu/ft2- r North East South West Space Heating - 5.28 3.70 1.58 3.48 1.80 3.10 2.17 3.32 1.96 Space,Cooling 68.45 40.40 28.06 39.82 28.64 41.69 26.76 41.77 26.68 Fans 13.69 14.78 -1.10 14.59 -0.90 15.22 -1.53 15.24 -1.55 Domestic Hot Water 13.67 9.73 3.94 9.73 3.94 9.73 3.94 9.73 3.94 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 101.09 68.61 32.48 67.62 33.47 69.74 31.34 70.06 31.02 Percent Better Than Standard: 32.1 % 33.1 % 31.0 % 30.7 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four Orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 727 140 Fuel Available at Site: Natural Gas (S) 739 60 Raised Floor Area: 0 (W) 466 52 Slab on Grade Area: 0 (N) 1,529 116 Average Ceiling Height: ! 11.7 Roof 2,668 0 Fenestration Average U-Factor: 0.30 TOTAL: 368 Average SHGC: 0.30 Fenestration/CFA Ratio: 13.8 REMARKS-- 2- 4 STATEMENT'OF COMPLIANCE - This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts' 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author . Company GMEP Engineers s� "- 1/3/2013 Address 4400 Campus Drive Name Gangyi Zhou City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone 9497521612 Signed Date The individual with overall design responsibility hereby certifies that the.proposed-building=design represented in this set of construction documents is consistent with the other compliance form s-and'Work" heetQwithtthespeolfications, and with any other calculations submitted with this permit application{; and `ecjog6njzeshat�complianc�eF'uing�duct design, duct sealing, verification of refrigerant charge, insulation installation=quality, and building en:velo. a seali g require installer testing and certification and field verification by an approved HERS aterf � i% U i ' FGN CONSTRUCTION. Designer or Owner (per Business & Professions Co die) Company POON DESIGN INC Address 315 S. Beverly Drive, Suite 206 Name - 1 r,, TF �- BY City/State/Zip Beverly Hills, CA 90212 Phone 310-277-8855 Signed License # Date i EnenqvPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:27:22 /D: 62649 Page 3 of 6 Reg: 212-N0070419C-000000000-0000 Registration Date/Time: 2012/12/13 18:31:56 HERS Provider: CalCERTS, Inc 17lectroni,cally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 'lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential . (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN J Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame Wall 792 , 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 82 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Wall 245 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 414 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Roof 1,452 0.028 1 R-38 01 0 New 4.2.2-A19 _ Conditioned Area Wall 621 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 342 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 597 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Roof 1,216 0.028 R-38 0 0 New 4.2.2-A19 Conditioned Area FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm• Status Glazing Type Location/Comments 1 Window 22.0 0.300 NFRC 0.29 NFRC 0 New Andersen Double Pane Low E(1 Conditioned Area 2 Window 22.0 0.300 NFRC 0.29 NFRC 0 New Andersen Double Pane Low E(1 Conditioned Area 3 Window 8.0 0.290 NFRC 0.33 NFRC 0 New Andersen Double Pane Low E(2 Conditioned Area 4 Window 8.0 0.290 NFRC 0.33 NFRC 0 New Andersen Double Pane Low E(2 Conditioned Area 5 Window._ 28.2 0.290 NFRC _ 0.29 NFRC" ' ,. " __0 New Plastpro Low E _ _ _ Conditioned Area 6 Window' '� 18.0 0.290 NFRC ,r %0.33 NFRC 180 New f' l Andersen Double Pane Low E(2 Conditioned Area 7 Window 11.0 0.290 NFRC / 0.33 `NFRC 90 New - ; Andersen, Double Pane Low E(2 Conditioned Area 8 Window 11.0; : 0.290 NFRC 0.33 NFRC &-f 90 New y`r Andersen -Double Pane Low E(2 Conditioned Area - 9 Window 1,1!0 f 0.290 NFRC 0.33 NFRC v • 90 New Andersen Double Pane Low E(2 Conditioned Area,,, 10 Window .,,# J28.2 ► 0.290 NFRC 0.29 NFRC A90 News J Plastpro Low E It 1 ' Conditioned Area 11 W/ndowmg 0 t, 28.2 0.290 NFRC -0.29 NFRC '. - _ ' 90 New i*. Plastpro Low E 4-._-w:,�/ . Conditioned 'Area tt: 12 Window 28.2 0.290 NFRC 0.29 NFRC 90 New Plastpro Low E "` Conditioned Area 13 Window 28.0 0.280 NFRC 0.28 NFRC 270 New Andersen Double Pane Low E(4 Conditioned Area - 14 . Window 8.0 0.290 NFRC 0.33 NFRC 270 New Andersen Double Pane Low E(2 Conditioned Area 15 Window 8.0 0.290 NFRC 0.33 NFRC 270 New Andersen Double Pane Low E( Conditioned Area 16 Window 8.0 0.290 NFRC 0.33 NFRC 270 New Andersen Double Pane Low E( Conditioned Area (1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Overhang Left Fin Right Fin H t Wd Len H t LExt RExt Dist . Len H t Dist Len H t 1 Roll -down Blind or Slats 0.13 2 Roll -down Blind or Slats 0.13 3 Roll -down Blind or Slats 0.13 4 Roll -down Blind or Slats 0.13 �---� 5 JBug Screen 0.76- 6 Roll -down Blind or Slats 0.13 (` A Y ( J 7 Roll -down Blind or Slats 0.13 „I RAFE Y L C' 8 Roll down Blind or Slats 0.13 L)U' "- �,, ,,.- n 9 Roll -down Blind or Slats 0.13 10 Bug Screen 0.76 cc, Em CON j l FiU t 11 Bug Screen 0.76 12 JBug Screen 0.76 13 Roll -down Blind or Slats 0.13 r n-rG ----- 14 Roll -down Blind or Slats 0.13 r ------� 15 Roll -down Blind or Slats 0.13 16 Roll -down Blind or Slats 0.13 EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 4 of 6 Reg: 212-N0070419C-000000000-0000 Registration Date/Time: 2012/12/13 18:31:56 HERS Provider: Ca10ERTS, Inc sl'ectronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 :lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders).1/3/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN J Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments Cavity Exterior Frame Interior Frame FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGCz Azm Status Glazing Type Location/Comments 17 Window 28.2 0.290 NFRC 0.29 NFRC 0 New Plastpro Low E Conditioned Area 18 Window 22.0 0.320 NFRC 0.28 NFRC 90 New Andersen Double Pane Low E( Conditioned Area 19 Window-- 8.0 0.290 NFRC 0.33 NFRC 180 New Andersen Double Pane Low E Conditioned Area 20 Window 22.0 0.320 NFRC 0.28 NFRC 180 New Andersen Double Pane Low E( Conditioned Area 21 Window, ,:_ ,, 22.0 0.320 NFRC _ . _0.28 NFRC_.; .. _ _ 180 New,_,__,* Andersen•Double Pane Low. E( Conditioned Area �-� 1 r t X , . r ,, Nd� r �r° I. N 1.4 1 �. 1 ...- --. .d f 1 tf'J/,I,4l (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Overhang Left Fin Right Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len Hat 17 Bug Screen 0.76 c 18 Roll -down Blind or Slats 0.13 19 Roll -down Blind or Slats 0.13 20 Roll -down Blind or Slats 0.13 21 Roll -down Blind or Slats 0.13 EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 5 of 6 Reg: 212-N0070419C-000000000-0000 Registration Date/Time: 2012/12/13 18:31:56 HERS Provider: CalCERTS, Inc ^lectronically Filed by Gangyi thou and Authenticated at CalCERTS.com - 1/3/2013 electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013, CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN J Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 BUILDING ZONE INFORMATION System Name Zorie Name Floor Area ft Volume Year Built New Existing Altered Removed 3.5T Carrier COMMON AREA 1,452 20,328 3.5T Carrier Bedrooms 1,216 10,944 ` Totals 2,6681 01 01 0 HVAC SYSTEMS System Name Qty., Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status 3.5T Carrier 1 } Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 3.5T Carrier 1 ' Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New HVAC DISTRIBUTION h „V- �„ ,. !j :g e 7 r° �'•�a`�/I System Name Heating Cooling Duct Location .: Duct�4-7 R-Value V Ducts?"< Tested? Status 3.5T Carrier Ducted Ducted Conditioned 6.0 10 New 3.5T Carrier Ducted Ducted Conditioned 6.0 m New ❑ WATER HEATING SYSTEMS S stem Name at . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status RTG-95DVN 1 Instant Gas Kitchen Pipe Ins 199,900 0 0.84 n/a n/a New 11 & Cal HiN i A MULTI -FAMILY WATER HEATING DETAILS r, HYDRONIC'HEATI.NG S;Y�STEM (PIPING Control Hot Water Piping Length ft ?� \ 0 : 0 � Q — .it`_i�i�'�`-' 3,1 }4 OVED� s :C y,,,4 CotNISTRU System Name Pipe Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 6 of 6 Reg: 212-N0070419C-000000000-0000 Registration Date/Time: 2012/12/13 18:31:56 HERS Provider: CalCERTS, Inc MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name CORAL MOUNTAIN - PLAN J 1 Date 11212013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures:. 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. * 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM El 677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight-fittingtight-fifting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation. having an installed thermal resistance of R-12 or greater. §150(j)l B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internainsu'lation-R-value-is�ndicated-on-the-exterior of the tank. I CITY OF I A Ql JINITA M §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, no recirculatingsections of hot water pipes are insulated per Standards Table 150-B. -recirculatiog systems, and -entire len th of oui�Ljii �U d` 0ar't_ t Y LJtt'gj . §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping water tank shall be insulated to Table 150-B and Equation 150-A. in sulatedtbetweQr -64 jng�s'�ource and indi ect hot D ran is Q1 IrlTi §150(j)2: Pipe insulation for steam hydronic heating systems or hot water syste 123-A. s >15 psi, meets fie requiremen s of Stan ards Table 150 ' 3A: Insulation is protected from damage, including that due to sunlight, mdoi`sitbT6-: a ui ent-malWt'enance.,-and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes-a-vaper-r-etardar t-or-is-enclosed-entirely in conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 9 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN J 11212013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 15,0 k . 150 k 7: All switchinq devices and controls shall meet the requirements of&+50 k` 9_ r n t f t INIT §150(k)8: A minimum of 50 percent of the total rated wattage of permanently in'stalled'l gl ting intkitche""n's"shallll be ..,igh fficacy. b EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft'2 or 00 rafts.,for dwglling-units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminairVs m thee-t�he�n e�coMtrol' led -bey a man al on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmablecontrolfsystem; and all Id tly installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utilityrrooms,�E;e�FiighfeW a y�an�d� contro led by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear fjot of illuminated cabinet. r,n F __ BY i� EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 10 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN J 1 11212013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130 d . §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. LA QUINT AAFETYDEPBUILDING DINFT. F APPROVED ONSTRUCTION — BY L EnergyPro 5.1 by EnergySoft llser Number: 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 11 of 15 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN J 11212013 • ANNUAL TDV ENERGY USE (kBtu/s ft- r) - . PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard % Better" Space Heating 5.28 3.70 1.58 32.48 / 101.09 - 32.1 Space Cooling 68.45 40.40 28.06 Cooling Standard Heat Rejection 0.00 0.00 0.00 28.06 Indoor Fans 13.69 14.78 -1.10 Incentive Eligibility Yes No Domestic Hot Water 13.67 9.73 3.94 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) m ❑ Conditioned Floor Area = 2,668.0 ft2 TOTALS: 101.09 = 68.61 32.48 Number of Bedrooms = 4 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard proposed Margin Facing North Peak Demand kW 8.2 5.6 1 2.6 I Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms (kWh) (therms) (kWh) (therms) Space Heating 0.00 88.05 0.00 61.79 0.00 26.26 Space Cooling 8,169.54 0.00 4,732.92 0.00 3,436.62 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,785.62 0.00 1,866.54 0.00 -80.91 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 91955.17 333.38 6.599.46 r 236.12 3,355.71 1 97.27 - • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available from step 2- Rate � (from Ste 3 Subtotal Electricity °i only through the California (kWh)32.1 o.s2 x 3,35s.71 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 32.1 % �' 160 X 2.6 = $416 NOT GUARANTEED. Projects must meet all other program �- $/� kw Natural Gas 32.1 % 3.67 X 97.27 $357 requirements t0 qualify. Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific Gas and N t J I NTA Energy Star Incentiv,�e ITV OFn/a- � �10% n/a & Electric Company RAFETY DEPT. r,,l`Ir Y Green Home InceritivRe�jlt Yea -�0° ® n/a SOu'1'HERN CALIFORNIA I "",TRUCTION E D I S O N �� � Compact Home F Incentive ,n/a x 15 /o = Fl► . i n/a An POISON INTERNATIONAL.° Company /+� Photovoltaic IncentivgATE ---n/a - SAGE I DC Rating kW A'Sempra Energy utility' NSHP �T6e ■\ california Total Wm°am advanced homes" A a!Sempra Energy mmY *% Better than in this equation is limited to 45% EnergyPro 5.1.7.7 by EnergySoft User Number: 8165. RunCode: 2013-01-02T16:27:22 ID: 62649 Page 12 of 15 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN J 1/2/2013 - • ANNUAL TDV ENERGY USE kBtu/s ft- r) PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard %Better• Space Heating 5.28 3.48 1.80 . 33.47 / 101.09 - 33.1 Space Cooling 68.45 39.82 28.64 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 28.64 / 68.45 Indoor Fans 13.69 14.59 -0.90 Incentive Eligibility Yes No Domestic Hot Water 13.67 9.73 3.94 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) m ❑ Conditioned Floor Area = 2,668.0 ft-- TOTALS: 101.09 67.62 33.47 Number of Bedrooms = 4 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing East Peak Demand kW 8.2 1 5.2 3.0 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms (kWh) (therms) kWh (therms) Space Heating 0.00 88.05 0.00 58.12 0.00 29.93 Space Cooling 8,169.54 0.00 4,775.02 0.00 3,394.53 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,785.62 0.00 1,879.44 0.00 -93.82 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 �9955.17 TOTALS: 333.38 6,654.46 232.45L 3,300.71 100.93 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available (from ste 2) Rate (from Ste 3) Subtotal �' X Electricity only through the California (kWh) 33.1 % 0.95 3,300.71 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 33.1 °� �' 166 X 3.0 = $498 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 33.1 % �' 3.78 xi 100.93 = $382 requirements to qualify. Potential incentives are $/therm therm subject to program limitations Base Incentive APacific Gas and Energy Star Incentive n/a x 10% s Electric Company Green Home Incentive , rn,a: x o-UINTT� n/a SOUTHERN CALIFORNIA U 1 1 o ° SAFETY DEPT .� > E D I S O N Compact Home Incentive B� sl �IlVn�a x 1s,ED - n/a - � pi-R.�� ��V An F.DISON IA'l'l?H+V:1'1'IONAI_° Company Photovoltaic Incentive FOR �/ fix+ TR i 1 /1 _ n/a SDG� E DC Rating kW t DATE n Sempra Energy uurty %�1 P D, U �I cafi10r11 Zia Total advanced homes" A *Sempra Energy.tuay *% Better than in this equation is limited to 45% EnergyPro 5.1.7.7 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:27:22 ID: 62649 Page 13 of 15 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN J 11212013 • ANNUAL TDV ENERGY USE (kBtu/s ft- r) PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard % Better* Space Heating 5.28 3.10 2.17 31.34 / I 101.09 Space Cooling 68.45 41.69 26.76 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 26.76 / 68.45 - 39.1 Indoor Fans 13.69 15.22 -1.53 Incentive Eligibility Yes No Domestic Hot Water 13.67 9.73 3.94 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) m ❑ Conditioned Floor Area = 2,668.0 ft2 TOTALS: 101.09 69.74 31.34 Number of Bedrooms = 4 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed margin Facing South Peak Demand kW 8.2 1 5.4 1 2.8 ENERGY COMPONENT Standard Proposed Margin Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh (therms) (kWh) (therms) (kWh) (therms) Space Heating 0.00 88.05 0.00 51.82 0.00 36.23 Space Cooling 8,169.54 0.00 5,081.75 0.00 3,087.79 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 11785.62 0.00 1,981.88 0.00-196.25 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 9,955.17 333.38 7,063.63 226.15 2,891.54 107.23 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available (from ste 2) Rate from Ste 3 Electricity Subtotal only through the California (kWh) X1 2,891.54 = $2,573 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) X 2.8 = $434 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas X requirements to qualify. 107.23 = $380 Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific Gas and Energy Star Incentive__ _�-----n�a= X 10% & Electric Company'�� � �I Q U Green Home Incentive,. ;r,tr ,Q n/a: IxE 16%-)EPT. SOUTHERN CALIFORNIA ED I S O N° _ r-. Compact Home Incentive A, r,ivaw 0 T;Ui IdJN = n/a An I'D1SON 1NTl:RNA770NA1_6 Company FOIE , Photovoltaic Incentive n/a x n/a = n/a Aff am DATE _---- BY-DGRating kVrl- A'Sempra Energy marry° OZ. NSHP cal if6m, a Total m T advanced homeM A a SempraEnergymary s *% Better than in this equation is limited to 45% EnergyPro 5.1.7.7 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:27:22 /D: 62649 Page 14 of 15 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN J 11212013 • ANNUAL TDV ENERGY USE (kBtu/s ft- r) - • PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard % Better' Space Heating 5.28 3.32 1.96 31.02 / 101.09 = 30.7 Space Cooling 68.45 41.77 26.68 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 26.68 / L 68.45 = 39.0 Indoor Fans 13.69 15.24 -1.55 Incentive Eligibility Yes No Domestic Hot Water 13.67 9.73 3.94 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) m ❑ Conditioned Floor Area = 2,668.0 ft2 TOTALS: 101.09 70.06 31.02 Number of Bedrooms = 4 Energy Star V3 Target = 15 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing West Peak Demand kW 8.2 1 5.7 2.5 Standard Proposed Margin E ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh (therms) kWh therms (kWh) therms Space Heating 0.00 88.05 0.00 55.39 0.00 32.66 Space Cooling 8,169.54 0.00 4,967.03 0.00 3,202.51 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,785.62 0.00 1,943.55 0.00-157.93 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.001 0.00 TOTALS: 9,955.17 333.38 6,910.58 229.72 1 3,044.59 1 103.66 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available (from step 2) Rate from Step 3 Electricity �� Subtotal only through the California (kWh) 30.7 % 0.88 x 3,044.59 = $2,679 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 30.7 % �� 154 X 2.5 = $385 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 30.7 % �' 3.51 x 103.66 = $364 requirements to qualify. Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific Gas and Electric Company Energy Star Incentive - p/a x 109/. A tit i NTA N n/a t J r ,l Green Home Incentive[- i,LDiNC- X�A"'TY DEPT_ n�a SOUTHERN CALIFORNIA /F�nI�gwtD o -\ �- E D I S O N v Compact Home Incentive _�� /q, i�T1' TION = n1a An EDISON I fERA54770NAL6 Company Photovoltaic Incentive n/a x n/a = n/a ^0 SDGC ANEW DAT --- DC atin kW A A' Sempra Energy uerty .� j 7\ NSHP 1 calif6 nla Total m homes- A Sempra Energy many- advanced `% Better than in this equation is limited to 45% EnergyPro 5.1.7.7 by EnergySoft User Number: 8165 RunCode: 2013-01-02T16:27:22 /D: 62649 Page 15 of 15 BUILDING ENERGY ANALYSIS REPORT PROJECT: CORAL MOUNTAIN -PLAN Z LA QUINTA, CA Project Designer- POO.N DESIGN INC 315 S. Beverly Drive, Suite 206' Beverly, Hills, CA 90212 310-2-77-8855 Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521612 CITE' OF LA QUINTA Job Number 3UILDING &SAFETY DEPT. 62649 APPROVED FOR CONSTRUCTION Dater DATA BY a 6/17/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 5.1 by Energ Soft User Number:8165 RunCode: 2013-06-11T09:44:02 ID: 62649 TABLE OF CONTENTS Cover Page Table of Contents Form CF-1 R Certificate of Compliance Form MF-1 R Mandatory Measures Summary Form UTIL-1 R Utility Incentive Worksheet CITY OF LA QUINTA BUILDING & SAFEIY DEPT. APPROVED FOR CONSTRUCTION DATE A EnergyPro 5.1 by EnergySoft Job Number: ID: 62649 User Number: 8165 1 2 3 8 11 . .1tctronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/17/2013 'electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name CORAL MOUNTAIN - PLAN Z Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/17/2013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,708 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Wall Wood Framed R-21 1,816 New Roof Wood Framed Rafter R-38 2,708 New FENESTRATION U- Exterior Orientation Area(fe) ,Factor SHGC Overhang Sidefins Shades 'Status Rear (Kq 33.9 0.290 0.33 none none Roll -down Blind or Slats New Front (E) _ - _ 357.2 0.560,,�0.32—none., ,—none Bug.ScreenpwAt.,,,, New Front (E).rr,-' 35.3 ? ,F 0:380 0.34 none lt none =fir. i Roll-iiown Blind or Slats New Front (E) �2ti.2 � '0.290 0.29 none � rnone �, Bug Screen � t% New -; Left (S) ,;44.0 0.290 0.33 none none Roll -down Blind or Slats rn` �'` ,New Right ,� is ��-r �. -rI; Ri g O 28.6. 0.310�, �0.31 ' none •none , �'`� Roll-iiown Blind or Slats. �' � New Rear (W) 26.6 0.280 0.28 ` none none Roll -down Blind or Slats New Left (S) _ _ "�, 44.0 0.310 0.31 none none Roll -down Blind or Slats New j HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New w �- �A nt ill\IT HVAC DISTRIBUTION Location HeatingCoolingDuct ` �• "' �'� ° uct =Ii'�G SAF c DEPT. Location' ..e ale S atus 3.5T Carrier Ducted Ducted Conditioned' 6 .. , f-%%fflTa, � _T w 3.5T Carrier Ducted Ducted Conditioned 6.0 NJ w WATER HEATING DATE---- Qty. Type Gallons Min. Eff Distribution Status 1 Instant Gas 0 0.84 Kitchen Pipe Ins New Energ Pro 5.1 by Energ Soft User Number. 8165 RunCode: 2013-06-11 T09:44:02 ID: 62649 Page 1 of 5 Reg: 212-NO07042OC-000000000-0000 Registration Date/Time: 2012/12/13 18:32:19 HERS Provider: CalCERTS, Inc -31'ectronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/17/2013 3lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN Z Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 611712013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. i 4 ii)''^�} • •� J`�. Tom'' .,^'�'� {�■r/'---} ,%,�%/�+��.... ,j "' _ f•7/ I jai HERS REQUIREDYERIFICATION Items in this section require fieldae`sting and/or verification by a certified HERS Rater. The,inspect r- rn t receive a completed CF-413 form for each of the measures listed below for final to be given. The Cooling. System Bryant 315JA V048090 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. r - Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria.. The Cooling System Bryant 315JAV048090 includes credit for a 13.0 EER Condenser. _ dified-14ERS-rater-must field -verify th'e insta correct Condenser. I-ITY nF I A O U I NTA lation of the The HVAC System 3.5T Carrier incorporates HERS Verified Refrigerant Charge or a Char ge I is for Display.-. tel.�l`�l�JINU &SAFETY DEPT. Compliance credit for quality installation of insulation has been used. HERS field verification is re iced. ROV r:(:)R GC)r\IqTRLJCT10N The HVAC System 3.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rate verify the installation of the HVAC unit and all Ducts and Plenums. p must visually The HVAC System 3.5T Carrier includes credit for verified adequate airflow. A certifieddHERS�rater must diagnotically_measure-airf/owjof System. l the HVAC 1 The. HVAC System 3.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnerqyPro 5.1 by EnerqySoft User Number: 8165 RunCode: 2013-06-11 T09:44:02 ID: 62649 Pa e 2 of 5 Reg: 212-NO07042OC-000000000-0000 Registration Date/Time:'2012/12/13 18:32:19 HERS Provider: CalCERTS, Inc Flbctronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/17/2013 :lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date CORAL MOUNTAIN - PLAN Z ❑ Multi Family ❑ Existing+ Addition/Alteration 611712013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV kBtu/ft2- r North East South West Space Heating 4.32 4.71 -0.39 3.69 0.63 4.10 0.22 , 4.55 -0.23 Space Cooling 70.18 41.55 28.63 47.36 22.82 49.00 21.18 49.33 20.86 Fans 13.96 15.25 -1.30 17.27 -3.32 17.88 -3.92 17.86 -3.91 Domestic Hot Water 13.47 9.59 3.88 9.59 3.88 9.59 3.88 9.59 3.88 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 101.93 71.10 30.83 77.91 24.02 80.58 21.35 81.33 20.59 Percent Better Than Standard: 30.2 % 23.6 % 20.9 % 20.2 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four Orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 713 421 Fuel Available at Site: Natural Gas (S) 808 88 Raised Floor Area: o (►M 387 61 Slab on Grade Area: 0 (N) 506 28 Average Ceiling Height:. 11.1 Roof 2,708 0 Fenestration Average U-Factor: 0.46 TOTAL: 597 Average SHGC: 0.32 Fenestration/CFA Ratio: 22.1 % REMARKS ; 4 fin,, J STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author ' p Y Company GMEP Engineers 6�' ' Address 4400 Campus Drive Name Gan 9yi Zhou 6/17/2013 City/State/ZipCity/State/Zip Newport Beach, CA 92660 Phone 9497521612 Si ned ,-r Date `''r"!� b. ,n l t g I tl The individual with overall design responsibility hereby certifies that thelproposecYbuilding_desigr� rep se red in this set of construction documents is consistent with the fIor the ific tions, other compliance Vs and}v�rorksheetsfwFith spe and with any other calculations submitted with this permit application, and recognizespthali --pliance sing duct design, duct sealing, verification of refrigerant charge, insulation installation�quality_�a;nd-builri�nng- equire te�rvelopejs,paling installer testing and certification and field verification -by an approved HERS-raRer�U Designer or Owner (per Business & Professions Code) Company POON DESIGN INC DATE ------ BY Address 315 S. Beverly Drive, Suite 206 Name City/State/Zip Beverly Hills, CA 90212 Phone 310-277-8855 Signed License # Date EneCqyPro 5.1 by EnerqVSoft User Number: 8165 RunCode: 2013-06-11T09:44:02 ID: 62649 Page 3 of 5 Reg: 212-NO07042OC-000000000-0000 Registration Date/Time: 2012/12/13 18:32:19 HERS Provider: CalCERTS, Inc 71bctronic�ally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/17/2013 :lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN Z Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 611712013 OPAQUE SURFACE DETAILS Surface Type Area Ll- I FactorPR-21 Insulation _ Azm Tilt Status Joint Appendix 4 Location/Comments Exterior Frame Interior Frame Wall 81 0.069 270 90 New 4.3.1-A6 Conditioned Area Wall 110 0.069 90 90 New 4.3.1-A6 Conditioned Area Wall 258 0.069 180 90 New 4.3.1-A6 Conditioned Area Roof 1,117 0.028 -38 0 0 New 4.2.2-A 19 Conditioned Area Wall 478 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area, Wall 182 0.069 R-21 90 90 1 New 4.3.1-A6 Conditioned Area Roof 625 0.028 R-38 0 0 New 4.2.2-A19 Conditioned Area Wall 245 0.069 R-21 270 90 New 4.3.1-A6 Conditioned Area Wall 462 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Roof 966 0.028 R-38 0 0 New 4.2.2-A 19 Conditioned Area FENESTRATION SURFACE DETAILS ID Type Area LI-Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 2.8 0.290 1 NFRC 0.33 1 NFRC 270 New Anderson Double Pane Low E(1 Conditioned Area 2 Window 220.2 0.560 NFRC 0.32 NFRC 90 New Fleetwood Conditioned Area 3 Window 137.0 0.560 NFRC 0.32 NFRC 90 New Fleetwood Conditioned Area 4 Window 35.3 0.380 NFRC 0.34 NFRC 90 New Fleetwood(1) Conditioned Area 5 Window.- ... 28.2 0.290 NFRC 0.29 NFRC , _90 New _ ----- Plastpro Low E _ _ _ Conditioned Area 6 'Window' N 22.0 0.290 NFRC ;�, 0.33 NFRC 180 New Anderson Double Pane"Low E(1 Conditioned Area 7 Window 122.0 0.290 NFRC" r 0.33 `NFRC 180 New Anderson, Double Pane Low E(1 Conditioned Area 8 Window 20.0 0.310 NFRC . 0.31 NFRC t, -4 0 New Anderson Double Pane Low E(3 Conditioned Area 9 Window 8 0 f 0.310 NFRC 0.31 NFRC rt 0 New Anderson Double Pane Low E(3 Conditioned Area 4 �~ 10 Window ,J 110.4' a 0.290 NFRC 0.33 NFRC ,270 New I Anderson Double Pane Low E(1 Conditioned Area 11 WindowAK 1• ; 10.4 _ 0.290 NFRC <...6.33 NFRC - 270 New Anderson Double Pane Low E(1 Conditioned Area';"i 12 Window 13.3 0.280 NFRC 0.28 NFRC 270 New Andersen Double Pane Low E(2 Conditioned Area 13 Window - 13.3 0.280 NFRC 0.28 NFRC 270 New Andersen Double Pane Low E(2 Conditioned Area 14 .. Window ' 10.3 0.290 NFRC 0.33 NFRC 270 New Anderson Double Pane Low E(1 Conditioned Area 15 Window 1 22.0 0.310 NFRC 0.31 NFRC 180 New Anderson Double Pane Low E0 Conditioned Area 16 Window 1 22.0 , 0.310 NFRC 0.311 NFRC 180 New Anderson Double Pane Low E(A Conditioned Area (1) LI-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value - 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Overhang Left Fin Right Fin H t Wd Len Wit I LExt RExt Dist Len H t Dist Len H t 1 Roll -down Blind or Slats 0.13 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Roll -down Blind or Slats 0.13 5 Bug Screen 0.76. N t^ I P I A 01 IIIN I A 6 Roll -down Blind or Slats 0.13 . n rr-T`l C!� 7 Roll -down Blind or Slats 0.13 _ �-►� a �`" `- ' ' 8 Roll -down Blind or Slats 0.13 M A E: P P- 9 Roll -down Blind or Slats 0.13°^ ,C.rn_i 10 Roll -down Blind or Slats 0.13 11 Roll -down Blind or Slats 0.13 12 Roll -down Blind or Slats 0.13 .. By - 13 Roll -down Blind or Slats 0.13 14 Roll -down Blind or Slats 0.13 15 Roll -down Blind or Slats 0.13 16 Roll -down Blind or Slats 0.13 EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11T09:44:02 ID: 62649 Page 4 of 5 Reg: 212-NO07042OC-000000000-0000 Registration Date/Time: 2012/12/13 18:32:19 HERS Provider: CalCERTS, Inc Flhctronisally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 6/17/2013 'lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 6/17/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name CORAL MOUNTAIN - PLAN Z Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 611712013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft Volume Year Built New Existing Altered Removed 3.5T Carrier COMMON AREA 1,117 15,636 3.5T Carrier Master Bed 625 5,625 Bedrooms/Library 966 8,694 Totals I Z 7081 01 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status 3.5T Carrier 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New 3.5T Carrier 1 Central Furnace 80% AFUE Split Air Conditioner 15.5 SEER Setback New J I HVAC DISTRIBUTION .1,�.._: J System Name Heating Cooling Duct Location _..Duct!; ' R-Value L- Ducts'r'�. Tested? Status 3.5T Caller - c Ducted Ducted Conditioned 6.0 m New 3.5T Carrier Ducted Ducted Conditioned 6.0 m New ❑ , 7 ❑ WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status RTG-95DM 1 Instant Gas Kitchen Pipe Ins 199,900 0 0.84 n/a n/a New � 1111 KAT MULTI -FAMILY WATER HEATING DETAILS (;HYD,RONI'C MEA1TI_NGJSYS, PIPING Control Hot Water Piping Length N Q � 'UILDING b/A -c PPROVED FOR CONSTRUC System Name ION Pipe Length Pipe Q iameter Insul. Thick. Qty. HP Plenum Outside Buried— rr BY L I-% t - Ener Pro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11 T09:44:02 ID: 62649 Page 5 of 5 Reg: 212-NO07042OC-000000000-0000 Registration Date/Time: 2012/12/13 18:32:19 HERS Provider: CalCERTS, Inc MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name CORAL MOUNTAIN - PLAN Z Date 1611712013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no qreater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight-fittingtight-fiffing damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank,tnon�reycire dtmdsyst s�and�entirg lel gth of recirculatingsections of hot water pipes are insulated per Standards Table 150'-B._ §1500)2: Cooling system piping (suction, chilled water, or brine lines),and�piping" h9di'ate°debetWden h�eatinoource and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. A 0 D Q Q / §1500)2: Pipe insulation for steam hydronic heating systems or hot water yttem psi m�e�ts h8Ce dents o 123-A. FOH Standards Table 150 ' 3A: Insulation is protected from damage, including that due to sunlit ht, moisture, equipment maintenance, an4 wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes: a vapor retardar-o-is-enclosed-e t rely in conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11T09:44:02 ID: 62649 Page 8 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 6/17/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain-a=line-voltage=socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts Hof power -as. cetermined by'§130(aq andkshall not contain a � Q�' medium screw -base socket. v ... r T ' ` M pi 1l r�;ll�If �` e� �Ht"� � Lr 1 50k 6: Li htin integral to exhaust fans, in rooms other than kitchens, shall meet the a • licable requirements of 15b k . 150 k 7: All switching devices and controls shall meet the requirements of § 150 k 7%,PPRU % LU §150(k)8: A minimum of 50 percent of the total rated wattage of permanently instal led-lighting�i,N, @fcckid 6:Sh h11066 high icacy. EXCEPTION: U to 50 watts for dwelling units less than ore equal to 2,500 ft2 or 100�watts for dwellin units larger than1,[500p g q d g g ftz may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant dimmer, sensor, energy management system (EMCS), or.a multi -scene programmable control sy_st6W;_and-all-permaneihtly installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms_ar_e_high=efficaeyrand-connrolled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11 T09:44:02 ID: 62649 Page 9 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 611712013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. 1 §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. iJ� LA (�UI F(CITY DING & SAFETAwr"PROVEFOR CONSTRUC OA CE � BY EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11 T09:44:02 ID: 62649 Page 10 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 6/17/2013 • ANNUAL TDV ENERGY USE kBtu/sqft-yr PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard %Better* Space Heating 4.32 4.71 -0.39 30.83 / 101.93 = 30.2 Space Cooling 70.18 41.55 28.63 Cooling Standard Heat Rejection 0.00 0.00 0.00 28.63 / 70.18 = 40.8 Indoor Fans 13.96 15.25 -1.30 Incentive Eligibility Yes No Domestic Hot Water 13.47 9.59 3.88 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) m ❑ Conditioned Floor Area = 2,708.0 ftz TOTALS: 101.93 71.10 30.83 Number of Bedrooms = 3 Energy Star V3 Target = 19 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing North Peak Demand kW 8.4 5.61 2.8 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 73.17 0.00 79.81 0.00 -6.63 Space Cooling 8,586.40 0.00 4,996.49 0.00 3,589.92 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,855.12 0.00 1,981.82 0.00-126.70 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 10,441,52 318.51 6,978.30 254.14 3,463.22 64.37 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available from ste° 2� Rate (from Ste 3 Su btotal only through the California Electricity (kWh) 30.2 / 0.87 X1 3,463.22 Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) 30.2 % > 151 X1 2.8 = $423 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 30.2 °i �' 3.45 x 64.37 = $222 requirements to qualify. Potential incentives are $/therm therm subject to program limitations I ("` '�-" 2013 C,ode�P�e`�aration t 010 IP p_ $o = 0 Pacific Gas and yi t . Ut. ILDING & SAFETY DEPT. Electric Company } r OV H Tier II = $o FOR CONSTRUCTION SOUTHERN CALIFORNIA Total ED I S O N` BY Incentive rate is pped at the 45% level An E01SON 1A71,kA`A770NA1.* Company �� ASempra Energy usury" california The advancedomesTM CGas ompany e A �jSempra Energy u uny- u EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11 T09:44:02 ID: 62649 Page 11 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 6/17/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard %Better* Space Heating 4.32 3.69 0.63 24.02 / 101.93 = 23.6 Space Cooling 70.18 47.36 22.82 -Cooling Standard Heat Rejection 0.00 0.00 0.00 22.82 / 70.18 = 32.5 Indoor Fans 13.96 17.27 -3.32 Incentive Eligibility Yes No Domestic Hot Water 13.47 9.59 3.88 Owner Incentive (> 15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (> 30%) ❑ m Conditioned Floor Area = 2,708.0 ft2 TOTALS: 101.93 77.91 24.02 Number of Bedrooms = 3 Energy Star V3 Target = 19 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing East Peak Demand kW 8.4 L5.61 2.8 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 73.17 0.00 62.57 0.00 10.60 Space Cooling 8,586.40 0.00 6,138.20 0.00 2,448.20 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,855.12 0.00 2,378.21 0.00-523.09 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 10,441.52 318.51 8,516.42 236.90 1,925.11 1 81.61 • - POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available from ste2� Rate(from Ste 3 Subtotal only through the California ° Electricity (kWh) 23.6 � o.s8 x 1,925.11 Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) 23.6 % �' 118 x 2.8 = $330 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 23.6 °� �' 2.70 x 81.611 = $220 requirements to qualify. Potential incentives are $/them, them, subject to program limitations 2013 Code Preparation = $o Pacific Gas and Electric Company NSHP Tie II CITY OF LA QU I N r = $o BUILDING & SAFETY DEPT. SOUTH[RN CALIFORNIA 4 Total EJEDISON` $415,%8 9v IR®e rate s Gapped at the el level FORCONSTRUCTI15N,tiv An 601SON IA7hRNA770,\4/.* Company 1r A SempraEnergy uerty cafforma ne Gas anced oo.�'�/TM Company t7a1 V A Sempra Energy utiiity- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11T09:44:02 ID: 62649. Page 12 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 6/17/2013 • ANNUAL TDV ENERGY USE kBtuIsgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard %Better• Space Heating 4.32 4.10 0.22 21.35 / 101.93 = 20.9 % Space Cooling 70.18 49.00 21.18 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 21.18 / 1 70.18 = 30.2 Indoor Fans 13.96 17.88 -3.92 Incentive Eligibility Yes No Domestic Hot Water 13.47 9.59 3.88 Owner Incentive (-15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) ❑ I71 Conditioned Floor Area = 2,708.0 ft2 TOTALS: 101.93 80.58 21.35 Number of Bedrooms = 3 Energy Star V3 Target = 19 % • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing South Peak Demand k F 8.4 F 6.2 1 2.2 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 73.17 0.00 69.49 0.00 3.68 Space Cooling 8,586.40 0.00 6,266.01 0.00 2,320.40 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,855.12 0.00 2,435.51 0.00-580.39 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 1 0.001 1 0.001 0.00 0.00 0.00 0.00 10=441.52 318.51TOTALS: 10,441.52 318.51 8,701.52 243.83 1,740001 74.68 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available from ste 2) Rate from Ste 3 Subtotal only through the California Electricity (kWh) 20.9 % o.so X1 1,740.01 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 2o.s % n 104 X1 2.2 = $22s NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 2o.s % �� 2.3s X1 74.68 = $178 requirements to qualify. Potential incentives are $/therm them, subject to program limitations J201c Code Preparatio C ETY O F IN I A = $o Pacific Gas and Electric Company BUILDING & SAFETYNSHFP Fier 11 = $o APPROVED SOUTHERN CALIFORNIA FOR CONSTRUCT4Oa ED I S O N' Incentive rate i capped at the 45% level An 1XISON 1A71-N�A770AIAC Company DATE BY SO A *Sempra Energy utiiity' caflfforma, he � a ho-- TM ma,,Os CGas ompany �lJ {J Y Viad A Sempra Energy ueaty- u EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11T09:44:02 ID: 62649 Page 13 of 14 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN - PLAN Z 6/17/2013 • ANNUAL TDV ENERGY USE kBtu/sgft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard %Better* Space Heating 4.32 4.55 -0.23 20.59 / 1 101.93 = 1 20.2 Space Cooling 70.18 49.33 20.86 Cooling Standard Heat Rejection 0.00 0.00 0.00 20.86 / 70.18 = 29.7 Indoor Fans 13.96 17.86 -3.91 Incentive Eligibility Yes No Domestic Hot Water 13.47 9.59 3.88 Owner Incentive (-15%) 10 ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (-30%) ❑ m Conditioned Floor Area = 2,708.0 ftz TOTALS: 101.93 81.33 20.59 Number of Bedrooms = 3 Energy Star V3 Target = 19 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing West Peak Demand kW 8.4 1 7.0 1 1.4 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 73.17 0.00 77.21 0.00 -4.04 Space Cooling 8,586.40 0.00 5,865.55 0.00 2,720.86 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 1,855.12 0.00 2,280.09 0.00-424.97 0.00 Domestic Hot Water 0.00 245.33 0.00 174.33 0.00 71.00 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 10,441.52 318.51 8,145.64 251.54 2,295.88 66.96 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available from ste° 2� Rate (from Ste 3 Su btotal only through the California Electricity (kWh) 20.2 0.58 X1 2,295.88 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 20.2 % �> 101 X1 1.4 = $141 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 20.2 % �' 2.31 xi 66.96 = $155 requirements to qualify. Potential incentives are $/them, them, subject to program limitations 2013 Code Preparation = $o Pacific Gas and Electric Company CITY TY OF LA Q U MHATier I I = $o BUILDING & SAFETY DEPT. SOUTHERN �CALIFORNIA I P P 1 O V E Dotal E D I S O N' I FOR CON STR UCTI O'nJentive r e is capped at the 45% level I An IiDISOA' /NITRA'A770NA0 Company DATE SDep A Sempra Energy utauy¢ 0 advanceed omnosTM CGas ompany A �x Sempra Energy vurty- EnergyPro 5.1.7.1 by EnergySoft User Number: 8165 RunCode: 2013-06-11 T09:44:02 /D: 62649 Page 14 of 14 BUILDING ENERGY ANALYSIS REPORT PROJECT: CORAL MOUNTAIN ACCESSORY A LA QUINTA, CA Project Designer: POON DESIGN INC 315 S. Beverly Drive, Suite 206 Beverly Hills, CA 90212 310-277-8855 Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 9497521612 . 1 CITY OF LA QUINTA Job Number JsLDING & SAFETY DEPT. APPROVED 62649 FOR CONSTRUCTION Date: DATS BY 1 /3/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 5.1 by Energ Soft User Number. 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 TABLE OF CONTENTS Cover Page Table of Contents Form CF-1 R Certificate of Compliance Form MF-1 R Mandatory Measures Summary Form UTIL-1 R Utility Incentive Worksheet 1 2 3 8 11 EnergyPro 5.1 by EnergySoft Job Number: ID: 62649 User Number: 8165 ':lbctronixally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name CORAL MOUNTAIN ACCESSORY A Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 184 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features --'If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features (see Part 2 of 5) Status Wall Wood Framed R-21 430 New Roof Wood Framed Rafter R-38 .184 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Rear (E) 48.0 ; 0.290 0.33 none none Bug Screen New Rear (E) 28.2 0.290.y v*.,-0.29,...,none., ,.none &-4ug,Screen New y .fir• 1 I HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 7.70 HSPF Split Heat Pump 15.0 SEER Setback New . .. n el A r-r--r \/ r, C D HVAC DISTRIBUTION Location HeatingCoolingDuct lV c}c ter„ +— ' � C] U l L�J I fu � ����Duct LocationR-Valu Status r VVIV wv 1.5T Carrier Ducted Ducted Conditionedrl 6.0 New � I UAIt o WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Instant Gas 0 0.84 Kitchen Pipe Ins New Energ Pro 5.1 by Energ Soft User Number: 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Page 1 of 5 Reg: 212-N0071869B-000000000-0000 Registration Date/Time: 2012/12/20 18:05:29 HERS Provider: CalCERTS, Inc ^l&ctroniaally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 ;lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name CORAL MOUNTAIN ACCESSORYA Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. ti HER, REQUIRED VERIFEICATION �,tr � , � •. {r ...,• �r�. } � � �1. $� . �';•�.� ��;J j _.,. Items in this section require field testing and/or verification'by a certified HERS Rater. -The nspectorAmust receive a completed CF-411 form for each of the measures listed below for final to be given. The Cooling System 1.5T includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 1.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System 1.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System 1.5T Carrier includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 1.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. F ow nF I A QUINTA BUILDING & SAFETY DEPT- •AH H ICU `V' IC r-nR MNSTRUCTION {{ l DATE BY- EnergyPro 5.1 by EnerqySoft User Number: 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Page 2 of 5 Reg: 212-N0071869B-000000000-0000 Registration Date/Time: 2012/12/20 18:05:29 HERS Provider: CalCERTS, Inc 714ctronieally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 :lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type 10 Single Family ❑ Addition Alone Date CORAL MOUNTAIN ACCESSORY A ❑ Multi Family ❑ Existing+ Addition/Alteration 1/3/2013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV kBtu/ft2- r North East South west " Space Heating 5.89 3.49 2.40 4.07 1.82 4.16 1.74 3.07. 2.82 Space Cooling 156.96 148.56 8.40 152.18 4.78 121.16 35.80 142.49 14.47 Fans 32.35 46.61 -14.27 46.41 . -14.07 37.53 -5.18 44.65 -12.30 Domestic Hot Water 110.17 50.96 59.21 50.96 59.21 50.96 59.21 50.96 59.21 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 305.37 249.62 55.75 253.63 51.74 213.80 91.56 241.17 64.20 Percent Better Than Standard: 18.3 % 16.9 % 30.0 % 21.0 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four Orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (KO 162 0 Fuel Available at Site: Natural Gas (N) 91 0 Raised Floor Area: 0 (E) 162 76 Slab on Grade Area: 0 (S) 91 0 ti184 Average Ceiling Height: t 9.0 Roof 0 Fenestration Average U-Factor: 0.29 TOTAL: 76 . Average SHGC: 0.32 Fenestration/CFA Ratio: 41.4 % REMARKS • - • _: 4 17 STATEMENT'OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts''1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GMEP Engineers _ - _ Address 4400 Campus Drive Name Gangyi hotr.ITY OF N1 ! y w N� eTA 1/3/2013 t,, Cit /State/Zi Newport Beach, CA 92660 Phone 949752 61?11 iii niNG& SAsi near' DEPT. Date The individual with overall design responsibility hereby certifies that th'o propo s•-e ildEL esign rep esented in this set of construction documents is consistent with the other compliance forr�i MbwoVheetsl, itiI he sp cifications, and l� i rNuv with an other calculations submitted with this permit a lication, nW y p pp a ecognlzes that compliance us g duct design, duct sealing, verification of refrigerant charge, insulation instal)ation quality, and building envelope se ling require installer testing and certification and field verification by an approyAd HERS rate_[ BY Designer or Owner (per Business & Professions Code) Company POON DESIGN INC Address 315 S. Beverly Drive, Suite 206 Name - City/State/Zip Beverly Hills, CA 90212 Phone 310-277-8855 Signed License # Date EnengyPro 5.1 by EnerqySoft User Number: 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Page 3 of 5 Reg: 212-N0071869B-000000000-0000 Registration Date/Time: 2012/12/20 18:05:29 HERS Provider: CalCERTS, Inc 716ctroniaally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 :lectronically Siqned at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date CORAL MOUNTAIN ACCESSORY A ❑ Multi Family ❑ Existing+ Addition/Alteration 11312013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor CavityTExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 91 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 91 0,069 R-21 180 90 New 4.3.1-A6 Conditioned Area Wall 86 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 162 0.069 R-21 1 270 90 New 4.3.1=A6 Conditioned Area Roof 184 0.028 R-38 1 01 0 New 4.2.2-A 19 Conditioned Area e FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 24.0 0.290 NFRC 0.33 NFRC 90 New Andersen Double Pane Low E Conditioned Area 2 Window 24.0 0.290 NFRC 0.33 NFRC 90 New Andersen Double Pane Low E Conditioned Area •3 Window 28.2 0.290 NFRC 0.29 NFRC 90 New Plastpro Low E Conditioned Area i l . y _ ll N "V 'I f- Y 'N' tOrl N t/ f (1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Overhang Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len I H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 .3 Bug Screen 0.76 Ago] a [ A�LHMM LlMI� ff. A��M��ff EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Pa e 4 of 5 Reg: 212-N0071869B-000000000-0000 Registration Date/Time: 2012/12/20 18:05:29 HERS Provider: CalCERTS, Inc ,lt�ctronia7ally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 ;lectronically Signed at Ca10ERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name CORAL MOUNTAIN ACCESSORY A Building Type © Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft Volume Year Built New Existing Altered Removed 1.5T Carrier AREA 184 1,656 Totals 1 1841 0 0 0 HVAC SYSTEMS System Name Qty.- Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status 1.5T Carrier 1 Split Heat Pump 7.70 HSPF Split Heat Pump 15.0 SEER Setback New - HVAC DISTRIBUTION �:/.r "� .+lr ) J _.- - r r . System Name Heating Coolinq Duct Location Duct) -' Lt-- R-Value Ducts,�',C Tested? Status 1.5T Carrier Ducted Ducted Conditioned 6.0 m New i� ❑ WATER HEATING SYSTEMS S stem Name at . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status RTG-95DVN 1 Instant Gas Kitchen Pipe Ins 199,900 0 0.84 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o 75 — 4 `� : t ,- L. cx. SAFETY , e S stem-NamR QUINTA N fip�e-[) Length DEPT. Pipe - D'amete Insul. Thick. Qty. HP Plenum Outside Buried ❑ 1 FOR CONS . i ❑ _ V EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Page 5 of 5 Reg: 212-N0071869B-000000000-0000 Registration Date/Time: 2012/12/20 18:05:29 HERS Provider: CalCERTS, Inc MANDATORY MEASURES SUMMARY: Residential (Paae 1 - of 31 MF-1 R CORAL MOUNTAIN ACCESSORY A 1 11312013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used: More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1:. Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirements of 410-111(a). §117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool'roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. - *§150(a): Minimum R-19 insulation in wood -frame ceilinq or equivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§150(c): Minimum R-13 insulation in wood -frame wall or equivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent 1-1-factor. §150(f): Air retardinq wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Loci Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, -which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. - 1 §150(h): Heating and/or coolinq loads are calculated in accordance with ASHRAE. SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). ' §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water ' tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping '111 water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water system 123-A. 150 ' 3A: Insulation is protected from damage, including that due to sunlight, mo §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes conditioned space. §150(j)4: Solar water-heatinq systems and/or collectors are certified by the Solar CITY O I` eLAJeI N ire >&' jL, D?pt hoe r�equjre_rr1elrrt Sunda ture, a ur m t maantenan e L A wind. vapol-Wtbitddolr,ltsidnose' ely in %qgand Certificatio r oration. ct hot rds Table I EnergyPro 5.1 by EnergySoft User Number: 8165 . • RunCode: 2013-01-03T17:27:07 ID: 62649 Page 8 of 14 1 t. MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A 1 11312013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 1 50m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 1.50(k). 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7. .I- & \ §1 50(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens sKall�60h' h efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts>fer-dwelling units lar r- 11 n' 2, 00 ft2 maybe exempt from the 50% high efficacy requirement when: all low efficacy luminaires r�sthe +kk tehen are controlled by a manua on occupant 5-in-the r �r pp sensor, dimmer, energy management system (EMCS), or multi -scene hmanentl�y a progr fmmabl'Q control. system- and all�p installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility•_rooris are high ,e iff cabcy>arnd�y�±ttrolle by a manual -on occupant sensor. d 109 0_V� §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than'"20 wat?-+of power per linear foot o illuminated cabinet. QK r' 6� OP�E EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Page 9 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A 1 11312013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130 d . §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. P. Q�\tA GOAS�RU �U OP-�E EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Page 10 of 14 UTILITY INCENTIVE WORKSHEET �� UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A 1/3/2013 • ANNUAL TDV ENERGY USE kBtu/s ft- r) - • PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Margin Margin Standard % Better* Space Heating 5.89 3.49 2.40 55.75 / 305.37 = 18.3 Space Cooling 156.96 148.56 8.40 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 8.40 / 1 156.96 5.4 Indoor Fans 32.35 46.61 -14.27 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 184.0 ft2 TOTALS: 305.37 249.62 55.75 Number of Bedrooms = 1 Energy Star V3 Target = 15 - • ANNUAL SITE ENERGY USE Margin Facing North Average 2pm - 5pm . Standard Pro os�10 Peak Demand kW 1.1 0.1 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms (kWh) (therms) kWh (therms) Space Heating 102.31 0.00 60.61 0.00 41.70 0.00 Space Cooling 1,431.36 0.00 1,426.19 0.00 5.18 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 477.44 0.00-160.30 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1,964.24 62.941 -113.42 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available (from ste 2) Rate from Ste 3 Subtotal Electricity only through the California (kWh) X1 0.001= $o Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 18.3 % > 92 X 0.1 = $9 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 18.3 % �� 1 2.10 X 73.52 = $154 requirements to qualify. Potential incentives are $/therm therm subject to program limitations Base Incentive = $1s3 Pacific Gas and .19 Electric Company Energy Star Incentive n/a x 10% SOUl'WERN CALIFORNIA Green Home Incentive T 01%�A v1iO4 " n/a 1j EDISON°P A Compact Home Incettive 1�„ �$163; _�1�5°� . _ $24 1n Is DISOA'!A''1T:RA'ATION:1L° Company B Photovoltaic I �n/a X ' �N n/ _ n/a /+� SQ�7�u SO DC Rating kW D A �'Sempra Energy udrity° .� Lcentiv ���california . _ Total = $187 aSempra [nergy .m iy- advanced homesr� *% Better than in this equation is limited to 45% EnergyPro 5.1.7.7 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Page 11 of 14 INWORKSHEET UTIL-1 R cName Date :TILITY RAL MOUNTAIN ACCESSORY A 11312013 • ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Margin Margin Standard % Better' Space Heating 5.89 4.07 1.82 -51 741 305.37 = 16.9 Space Cooling 156.96 152.18 4.78 Cooling Standard Heat Rejection 0.00 0.00 0.00 L 4.78 / 156.96 = L 3.0 Indoor Fans 32.35 46.41 -14.07 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 184.0 ft2 TOTALS: 305.37 253.63 51.74 Number of Bedrooms = 1 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed margin Facing East Peak Demand kW 1.1 1.2 1 -0.2 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) (therms) kWh (therms) (kWh) therms Space Heating 102.31 0.00 69.03 0.00 33.28 0.00 Space Cooling 1,431.36 0.00 1,348.28 0.00 83.08 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 441.12 0.00-123.98 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1,858.43 7 62.94 -7.61 73.52 - • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available from step 2) Rate (from Ste 3) Subtotal only through the California Electricity (kWh) X1 0.00 = $o Advanced Homes Program for $/kwh kWh new construction and are Electricity (kW) 1s.s % 84 xi 0.01= $o NOT GUARANTEED. Projects must meet all other program Natural Gas 1s.s % �� $/kw kw 1.s4 X 73.52 J = $143 requirements to qualify. Potential incentives are $/therm therm subject to program limitations Base Incentive = $143 Pacific Gas and Energy Star Incentive n/a x 10% & Electric Company 'XQ'01N-r'A Green Home Incentive _ . __.---- --n/a SOUTHERN CALIFORNIA o �. E D I S O N i�'t�-- L_ I r, �yr Compact Home Incent Ve' tt\tr $1a3. �zE 5 �pEl'T' @DISON l+\'l'lzNNATlbNAl..° An Company Photovoltaic IncentiveCT10, ,,� n%- -x� N n/a n/a F� �J � ` DC Rating kW A Sempra Energy unrry° .� �'�, DATE S california �_ _ Total = $1sa wm advanced homes.. aSemyra Energy uur+y •% Better than in this equation is limited to 45% EnergyPro 5.1.7.7 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Page 12 of 14 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTA/NACCESSORYA 1/3/2013 • ANNUAL TDV ENERGY USE kBtu/s ft- r - • PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard %Better' Space Heating 5.89 4.16 1.74 91.56 / 305.37 = 30.0 Space Cooling 156.96 121.16 35.80 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 35.80 / 156.96 - 22.8 Indoor Fans 32.35 37.53 -5.18 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) 10 ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 184.0 ft2 TOTALS: 305.37 213.80 91.56 Number of Bedrooms = 1 Energy Star V3 Target = 15 % - • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Facing South Peak Demand kW 1.1 o.s1 0.2 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) (therms) kWh therms (kWh) therms Space Heating 102.31 0.00 70.33 0.00 31.98 0.00 Space Cooling 1,431.36 0.00 1,090.26 0.00 341.10 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 362.67 0.00 -45.53 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0'00 0.00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1 1,523.27 1 62.94 327.55 1 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available (from ste 2) Rate (from Ste 3) Subtotal only through the California Electricity (kWh) 30. x 327.55 = $282 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 30.0 % 15o x 0.2 = $30 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas X 73.52 = $252 requirements to qualify. Potential incentives are $/therm therm subject to program limitations Base Incentive = $5s4 Pacific Gas and 0 Energy Star Incentive n/a x 10% Electric Company Green Home Incentive n(a x�1:0'/0n/a SOUTHERN CALIFORNIA �i�ITA E D I S O N Compact Home Ince tIV�� �564Q ,,X�j/o+ pEPT. j _ $85 An EDISON AVTERAIATIONAL6 Company AV ��aF Photovoltaic Incentive �-�r/ai �xs' �' n /a = n/a SAGFOR CON r+BCR'a ing kw A ' Sempra Energy utirity° � O� _ n/a �� DATE californ�a �_N3P Total P,m � = $s4s A (--�'Sempra Energy urmy advanced home� s *% Better than in this equation is limited to 45% EnergyPm 5.1.7.7 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Page 13 of 14 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY 11312013 - • ANNUAL TDV ENERGY USE (kBtu/s ft- r) - • PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Margin Standard % Better' Space Heating 5.89 3.07 2.82 64.20 / 305.37 = 21.0 Space Cooling 156.96 142.49 14.47 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 14.47 / 156.96 Indoor Fans 32.35 44.65 -12.30 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) 10 ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ 121 Conditioned Floor Area = 184.0 ft2 TOTALS: 305.37 241.17 64.20 Number of Bedrooms = 1 Energy Star V3 Target 15 • • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing West Peak Demand kW 1.1 0.90.2 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh (therms) (kWh) (therms) kWh (therms) Space Heating 102.31 0.00 54.02 0.00 48.30 0.00 Space Cooling 1,431.36 0.00 1,382.24 0.00 49.12 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 461.10 0.00-143.96 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1,897.36 62.94 -46.54 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available (from ste 2) Rate from Ste 3 Electricity �� Subtotal only through the California (kWh) 21.0 % o.so X1 0.00 $o Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 21.0 % ��' 105 x 0.2 = $21 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas x 73.52 = requirements to qualify. $176 Potential incentives are $/therm therm subject to program limitations Base Incentive = $197 Gas and Energy Star Incentive n/a x 10% •"Pacific t, Electric Company Green Home Incentive n/a x 10% SOUTHERN CALIFORNIA 1 E D I S O N` Compact Home Incent'v ---$T x 1 %UINT-t _ LA N $30 An IsDISOA' li\''17 Hi\'A'I'1QA411..° Company C� y r , ..rnT. Photovoltaic Incentl e x �n/a = Q�� j rC 1 T vn I n/a � U _pINCn/a, ®��DC,� ating.kW A Sem ra Energy ° AP FOR CONSTRUCTION .� P 6Y °�'°ty NSHP - n/a -� califdrnia DATE -- B; -� $227 r. p. advanced ho A SempraEnergy muny '% Better than in this equation is limited to 459X EnergyEo 5.1.7.7 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:27:07 ID: 62649 Page 14 of 14 r BUILDING ENERGY ANALYSIS REPORT a PROJECT: CORAL MOUNTAIN ACCESSORY A OPTION LA QUINTA, CA Project -Designer: POON DESIGN INC 315 S. Beverly Drive, Suite 206 Beverly Hills, CA 90212 310-277-8855 Report Prepared by: Gangyi Zhou GMEP Engineers 4400 Campus Drive Newport Beach, CA 92660 -9497521612 Job Number: 62649 CITY ®� �'FETY DEPA Date: BUILDING & SA AP oROi� EDN 1 /3/2013 FOR DATE _— BY The EnergyPro computer program has been used to perform the calculations summarized i tQ�h's.comllianee-rep is program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Energ Pro 5.1 by Energ Soft User Number: 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 TABLE OF CONTENTS Cover Page Table of Contents Form CF-1 R Certificate of Compliance Form MF-1 R Mandatory Measures Summary Form UTIL-1 R Utility Incentive Worksheet CITY OF LA QUINTA BUILDING &SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY EnergyPro 5.1 by EnergySoft Job Number: ID: 62649 User Number: 8165 2 3 8 11 ,lectronidally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 :lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name CORAL MOUNTAIN ACCESSORY A OP Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 Project Address LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 184 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes 0 No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Wall Wood Framed R-21 373 New Roof Wood Framed Rafter R-38 184 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Rear (E) 133.4 0.560 0.32 none none Roll -down Blind or Slats New - -- 4 � �. ' 4 -#�`� 1] r:. T "� ,..,,,r�'tr- ..� �^--�r �'� �L.. • -,,G�� a �„�' 'S ���f� � �'�1 Ott. . 1 HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 7.70 HSPF Split Heat Pump 15.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct L CITY OF (ADuctlNTA ngefiQn)ING & SAF WILIPIPT Status 1.5T Carrier Ducted Ducted Conditione A h h P n%0Q ew FOR CO WATER HEATING Ot . Type Gallons Min. Eff Di6&rib1.1ti DATE BY f Status 1 Instant Gas 0 0.84 Kitchen Pipe Ins New Energ Pro 5.1 by Energ Soft User Number: 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 Page 175 Reg: 212-NO07187OB-000000000-0000 Registration.Date/Time: 2012/12/20 18:06:24 HERS Provider: CalCERTS, Inc 31ectronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 3lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF=1 R Project Name CORAL MOUNTAIN ACCESSORY A OPTI Building Type ® Single Family ❑ Addition Alone ❑Multi Family ❑Existing+ Addition/Alteration Date 1/3/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Compliance for all orientations is specified, see section 151 (c) 2 of the Standards and section 7.6.2 of the Residential Compliance Manual. t • HER, REQUIRED YERIFICATION Items in this section require field testing'a nd/or verification by,a certified HERS.Rater: -The inspector -must receive a completed CF-4R foam for each of the measures` listed below for final to begiven.' The Cooling. System, 1.5T includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System 1.5T Carrier includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System 1.5T Carrier incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System 1.5T Carrier has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. . The HVAC System 1.5T Carrier includes credit for verified adequate airflow. A certified. HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System 1.5T Carrier incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. P� no \t`-A r46 1 GGNb , EnerqyPro 5.1 by EnerqySoft User Number: 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 Page 2 of 5 Reg: 212-NO07187OB-000000000-0000 Registration Date/Time: 2012/12/20 18:06:24 ' HERS Provider: CalCERTS, Inc ^lectroniCally Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 :lectronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type 12 Single Family ❑ Addition Alone Date CORAL MOUNTAIN ACCESSORY OPTI ❑ Multi Family ❑ Existing+ Addition/Alteration 11312013 ANNUAL ENERGY USE SUMMARY Standard Facing Margin Facing Margin Facing Margin Facing Margin TDV kBtU/ft2- r North East South West Space Heating 5.89 11.74 -5.85 12.29 -6.39 12.52 . -6.63 11.21 -5.32 Space Cooling 156.96 144.11 12.85 150.45 6.51 132.54 24.42 142.79 14.17 Fans 32.35 33.45 -1.10 34.45 -2.11 30.69 1..66 33.14 -0.80 Domestic Hot Water 110.17 50.96 59.21 50.96 59.21 50.96 59.21 50.96 .59.21 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Totals 305.37 240.25 65.12 248.15 57.22 226.71 78.66 238.10 67.26 Percent Better Than Standard: 21.3 % 18.7 % 25.8 % 22.0 % BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: All Four Orientations Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (w) 162 0 Fuel Available at Site: Natural Gas (N) 91 0 Raised Floor Area: 0 (E) 162 133 Slab on Grade Area: 0 (S) 91, 0 Average Ceiling Height: s•o Roof 184 0 Fenestration Average U-Factor: 0.56 TOTAL: 133 Average SHGC: 0.32 Fenestration/CFA Ratio: 72.5 % REMARKS t. 1 4�. • `.,-,, i �s e �' ? E` , � . � -� � Fes. 'r.,�,/;..: y� Jjj � � �� yy STATEMENT OF COMPLIANCE This certificate of compliance!lists the building features and specifications needed to comply with Title 24,,Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GMEP Engineers Address 4400 Campus Drive Gan i Zhou T 1 3/2013 Name 9Y City/State/Zipd� Newport Beach, CA 92660 Phone 9497521612ne�u`� u EPT • D to The individual with overall design responsibility hereby certifies that the propots Cd,b�uild ng-design ep sented in this set .of construction documents is consistent with the other compliance forms and works e`ets, with, the-sReetfi�catio s, and with any other calculations submitted with this permit application, and recognizgs'ah t � piiq?)'c'c�u�sing� duct design, duct sealing, verification of refrigerant charge, insulation installation quality, ari tbu(jdid envelope sealing requi e installer testing and certification and field verification by an approved HERS rater. gY Designer or Owner (per Business & Professions Code) , DATE Company POON DESIGN INC • - r Address 315 S. Beverly Drive, Suite 206 Name City/State/Zip Beverly Hills, CA 90212 Phone 310-277-8855 Signed License # Date Enet1gyPro 5.1 by EnerqySoft User Number: 8165 RunCode: 2013-01-03T17:28:21 /D: 62649 Page 3 of 5 Reg: 212-NO07187OB-000000000-0000 Registration Date/Time: 2012/12/20 18:06:24 HERS Provider: CalCERTS, Inc Electronically Filed by Gangyi Zhou and Authenticated'at.Ca10ERTS.com - 1/3/2013 Electronically Signed at CalCERTS.com by Russell Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name CORAL MOUNTAIN ACCESSORY A OPTIC Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 11312013 OPAQUE SURFACE DETAILS Surface Type Area U- Factor Insulation Azm Tilt Status Joint Appendix 4 Location/Comments cavityTExterior Frame Interior Frame Wall 91 0.069 R-21 0 90 New 4.3.1-A6 Conditioned Area Wall 91 0.069 R-21 180 90 New 4.3.1-A6 Conditioned Area Wall 29 0.069 R-21 90 90 New 4.3.1-A6 Conditioned Area Wall 162 0.069 R-21 2701 90 New 14.3.1-A6 Conditioned Area Roof 184 0.028 R-38 0 0 New 4.2.2-A 19 Conditioned Area FENESTRATION SURFACE DETAILS ID Type Area U-Factor - SHGC2 Azm Status Glazing Type Location/Comments 1 Window 133.4 0.560 NFRC 0.32 NFRC 90 New Fleetwood Slider Conditioned Area 1 /I-,' I i % l` X a eJ `Syr. /yam +'• f J " / pJ i 1 { } � l ! . � ... %` t. .�1 �\ s11.. /�� j. IL I . (1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin Hat Wd Len Hat LExt RExt Dist Len H t Dist Len Hat 1 Roll -down Blind or Slats 0.13 1 1 _ Y Y_ 1 EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 Page 4 of 5 Reg: 212-NO07187OB-000000000-0000 Registration Date/Time: 2012/12/20 18:06:24 HERS Provider: CalCERTS, Inc ^lectronically Filed by Gangyi Zhou and Authenticated at CalCERTS.com - 1/3/2013 3lectronically Signed at CalCERTS.com by Russell -Jones (Alta Verde Builders) 1/3/2013 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of -5) CF-1 R Project Name CORAL MOUNTAIN ACCESSORYA OPT/ Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration. Date 11312013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft Volume Year Built New Existing Altered Removed 1.5T Carrier AREA 184 1,656 Totals 1841 01 01 0 HVAC SYSTEMS System Name Qt ' Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status 1.5T Carrier - - 1 , Split Heat Pump 7.70 HSPF Split Heat Pump 15.0 SEER Setback New r HVAC DISTRIBUTION ►I1 ., 11, x �,: ? System Name •t. Heatiri r - _-''Coolinq T '� - ^ c Duct Location Duct := R-Value Q✓ Ducts':10,�,C Tested? Status 1.5T Carrier t Ducted Ducted Conditioned 6. 01 m New WATER HEATING SYSTEMS S stem Name . Qty. Type Distribution Rated. Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status RTG-95DVN 1 Instant Gas Kitchen Pipe Ins 199,900 0 0.84 n/a _—n./a1, New �tT MULTI -FAMILY WATER HEATING DETAILS ONIG,x FI_E2A-TING�SYS,T�EM' PIPING Control Hot Water Piping Length ft, oJIN �N Q gvll DIN FOR G System Name �[ -Pipe Length Pipe iameter_J Insul. Thick. Qty. HP Plenum Outside Buried ❑ p,TE EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 Pace 5 of 5 Reg: 212-NO07187OB-000000000-0000 Registration Date/Time: 2012/12/20 18:06:24 HERS Provider: CalCERTS, Inc MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R Project Name CORAL MOUNTAIN ACCESSORY A OP, TION Date 1 11312013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118 a : Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF-1 R Form. * 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor. 150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor. * 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor. 150 f : Air retarding wrap is tested, labeled; and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no c1reater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: . 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation, having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated ort-Afire a error of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating step s, apd ddtirdeengthjof recirculatinq sections of hot water pipes are insulated per Standards Table §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping i suPate"d beiwegn,h`.'ea#fin°�'souree ar d indirec hot water tank shall be insulated to Table 150-B and Equation 150-A. U1L 1W "T I §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems 15 psi, dee�ts" th'e"requ`re�n, rats o tandard Table 123-A. 1 50' 3A: Insulation is protected from damage, including that due to sunlight, moist re, a ui ment maintenance, and wind! §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a 1p or retardant or is a .cfbse en 'rely-i conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Ratin, a d.CerC' ication Cor oration. EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 Page 8 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date CORAL MOUNTAIN ACCESSORY OPTION 11312013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 1 50m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 k 3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150 k 7: All switching devices and controls shall meet the requirements of §150(k)7. t II A it hens )§fi�jbe high"effi ' cyP-T, §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lig�tin PUN EXCEPTION: Up to 50 watts for dwelling less than to 2,500 ft2or 101 dle�ling wits units or equal watt;gffor arger;faanl2(5 may e exempt from the 50%high efficacy requirement when: all low efficacy luminaires in the kit hr 6argrd �Wolie b�y�moapuuaal or occupa t sensor, dimmer, energy management system (EMCS), or a multi -scene trbi'syst�er tall=perm programmable co on nJntlygb!galled luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility room are hig lv�'c-9W6h d`!iy a manual -on occupant sensor. v OeRc�; §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 0 watts of power per linear foot of illuminated cabinet. gY DATE EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 Page 9 of 14 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date CORAL MOUNTAIN ACCESSORY OPTION 1 11312013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. ® ��, �rtDrNG �®�' Eo N '�okG EnergyPro 5.1 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 Page 10 of 14 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY OPTION 1/3/2013 • ANNUAL TDV ENERGY USE (kBtu/s ft- r) - • PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard %Better' Space Heating 5.89 11.74 -5.85 1 65.12 Space Cooling 156.96 144.11 12.85 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 12.85 / 156.96 Indoor Fans 32.35 33.45 -1.10 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 184.0 ftz TOTALS: 305.37 240.25 65.12 Number of Bedrooms = 1 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pr*osed Margin Facing North Peak Demand kW 1.1 1.01 1 0.1 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms kWh therms kWh therms Space Heating 102.31 0.00 204.93 0.00-102.62 0.00 Space Cooling 1,431.36 0.00 1,287.86 0.00 143.50 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 322.17 0.00 -5.03 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1,814.96 62.94 35.85 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24` Incentive Savings on this report are available (from 2� Rate (from Ste 3 Subtotal only through the California Electricity (kWh) 21.3 0 o.s1 X 35.85 = $22 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 21.3 % �' 106 X 0.1 = $11 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas x 73.52 = $179 requirements to qualify. Potential incentives are $/therm therm subject to program limitations Base Incentive Pacific Gas and Electric Company Energy Star Incentive /a = t °/Q, v�N n/a �- a -�•� OE n/a Green Home Incentive �� nia x&1OD° vla SOUTHERN CALIFORNIA N V E D I SO N` Compact Home Incentive rs 2}eJx�`��`�� = $32 An I'DISON INTERNATIONAL ° Company Photovoltaic Incentive n/a x g`( a n/a �L /D R i S A Sempra Energy utility° ..� OP1E NSHP wm°am California Total = $2aa AQ-VSempraEnergy uwy- advanced home sTM *% Better than in this equation is limited to 45% EnergyPro 5.1.7.7 by EnergySoft User Number: 8165 Runcode: 2013-01-03T17:28:21 /D: 62649 Page 11 of 14 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A OPTION 1/3/2013 • ANNUAL TDV ENERGY USE (kBtu/s ft- r) - • PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard %Better• Space Heating 5.89 12.29 -6.39 1 57.22 / 1 305.37 = 1 18.7 Space Cooling 156.96 150.45 6.51 Cooling Standard Heat Rejection 0.00 0.00 0.00 1 6.51 / 156.96 = 4.1 Indoor Fans 32.35 34.45 -2.11 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 184.0 ft2 TOTALS: 305.37 248.15 57.22 Number of Bedrooms = 1 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing East Peak Demand (kW)1.1 1.1 1 -0.1 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh (therms) kWh (therms) Space Heating 102.31 0.00 212.48 0.00-110.17 0.00 Space Cooling 1,431.36 0.00 1,296.99 0.00 134.37 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 320.81 0.00 -3.66 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1,830.28 62.94 20.53 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available from ste 2) Rate(from Ste 3) Subtotal Electricity only through the California (kWh) 18.7 % 0.54 x 20.53 = $11 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 18.7 i° �� saX1 0.01 = $o NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 18.7 °i �� x 73.52 = $157 requirements to qualify. Potential incentives are $/therm therm subject to program limitations Base Incentive = $1s8 APacific Gas and -S Electric Company Energy Star Incentive n/a x 100 n/a v�N� SOUTHERN CALIFORNIA Green Home Incentive , n/a, �X V09/6 DE n/a 4 \Nlov E D I S O N°Compact�-' Home Incentive �-.� ON v C-- ��� $as8 �5./, VI $25 T An LiDISChV 1A''IT:Ri\41770t\(4.1.6 CompanyV n �Aff Photovoltaic Incentive DC Ratolk ` t A (kSempra Energy uclrry° pPlE / �c��omo.m w� p%��� calfi1 nia _ Total = $1s3 Q-I�Sempra Energy advanced homes*M A urfitY '% Better than in this equation is limited to 450% EnergyPro 5.1.7.7 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 Page 12 or 14 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORYAOPTlON 1/3/2013. • ANNUAL TDV ENERGY USE (kBtu/s ft- r) PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Pro osed Mar in Mar m Standard %Better• Space Heating 5.89 12.52 -6.63 78.66 / 305.37 = 25.8 Space Cooling 156.96 132.54 24.42 Cooling Standard Heat Rejection 0.00 0.00 0.00 24.42 / 156.96 - 15.6 Indoor Fans 32.35 30.69 1.66 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 184.0 ft2 TOTALS: 305.37 226.71 78.66 Number of Bedrooms = 1 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing South Peak Demand kW 1.1 1.0 1 0.1 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas (kWh) therms (kWh) therms kWh therms Space Heating 102.31 0.001 215.97 0.00-113.661 0.00 Space Cooling 1,431.36 0.00 1,154.01 0.00 277.36 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 289.09 0.00 28.05 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.00 0.00 0.00 0.001 0.00 TOTALS: 1,850.82 1 136.46 1,659.07 62.94 1 191.751 73.52 Wax, POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24' Incentive Savings on this report are available (from ste 2) Rate from Ste 3) Subtotal only through the California Electricity (kWh) 25.8 % �' 0.74 x 191.75 = $142 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) 25.8 % �' 129 x 0.1 = $13 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 25.8 % �> 2.95 X 73.52 = $217 requirements to qualify. Potential incentives are $/therm therm subject to program limitations Base Incentive = $372 Pacific Gas and Electric Company E Energy Star Incentive n x�0' Q� �' 1 is �- F SOUTHERN CALIFORNIA Green Home Incentive a t % �; SAF n EDISON Compact Home Incentive FtoVE $371 x °vSTRvcj �. p $5 V1' AnE.DISO\' Company Ar Photovoltaic Incentive n/a x = n/a sL DATE ing k 2 ASempra Energy ueI ry° NSHP The californa Total = $428 P.m advanced homes- n SempraEnergy urury *% Better than in this equation is limited to 45% EnergyPro 5.1.7.7 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:28:21 ID: 62649 Page 13 of 14 UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date CORAL MOUNTAIN ACCESSORY A OPTION 11312013 - • ANNUAL TDV ENERGY USE (kBtu/s ft- r) PERCENT BELOW TITLE 24 ENERGY COMPONENT Standard Proposed Mar in Margin Standard % Better* Space Heating 5.89 11.21 -5.32 1 67.26 / 305.37 = 22.0 Space Cooling 156.96 142.79 14.17 Cooling Standard Heat Rejection 0.00 0.00 0.00 14.17 / 156.96 = 9.0 Indoor Fans 32.35 33.14 -0.80 Incentive Eligibility Yes No Domestic Hot Water 110.17 50.96 59.21 Owner Incentive (>=15%) m ❑ Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 184.0 ft2 TOTALS: 305.37 238.10 67.26 Number of Bedrooms = 1 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Proposed Margin Facing West Peak Demand kW 1.1 1 1.0 F 0.1 Standard Proposed Margin E ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh (therms) (kWh) therms (kWh) therms Space Heating 102.31 0.00 196.60 0.00 -94.28 0.00 Space Cooling 1,431.36 0.00 1,290.59 0.00 140.78 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 317.14 0.00 322.17 0.00 -5.03 0.00 Domestic Hot Water 0.00 136.46 0.00 62.94 0.00 73.52 Pumps 0.00 0.00 0.00 0.00 0.00 0.00 TOTALS: 1,850.82 136.46 1,809.36 62.94 1 41.46 1 73.52 • POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title-24* Incentive Savings on this report are available (from ste 2) Rate (from Ste 3) Subtotal Electricity °i - only through the California (kWh) 22.0 o.s3 X 41.46 = $26 Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) X1 0711 = $11 NOT GUARANTEED. Projects must meet all other program $/kw kw Natural Gas 22.0 % � 1 2.52 X 73.521 = $185 requirements to qualify. Potential incentives are $/therm therm subject to program limitations Base Incentive = $222 I-�- Pacific Gas and 11PEnergy Electric Company Star Incentive CIF ', .A QU I _ I Ina x 10 /o �� I n/a , g L NG & SAFETYCY DI_ Green Home Incentive al NP1L0-1,0VGD n/a SOUTHERN CALIFORNIA ,t/` pno CONSTRUCTIO E D I S O N° Compact Home Incentive $222 x 15% _ $33 An EDISON INTERNATIONAL.° Company Photovoltaic Incentive I DAl n/ = n/a SOLEAW DC Rating kW A /�'Sempra Energy utirty .� �N NSHP california Total = $2ss advanced hoeY m s 1 AA!SempraEnergyumay '% Better than in this equation is limited to 45% EnergyPro 5.1.7.7 by EnergySoft User Number: 8165 RunCode: 2013-01-03T17:28:21 /D: 62649 Page 14 of 14