Loading...
07-1284 (CONR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: 4 4Q*m BUILDING & SAFETY DEPARTMENT BUILDING PERMIT 07-00001284 55075 MONROE ST 767-580-013--000000- NEW COMML — OTHER NON-RESIDENTIAL LOW DENSITY RESIDENTIAL 152524' Architect or Engineer: ------------------ LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. license Class: License No.: - E] Date: Contractor: • OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for -the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he o she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by anyp i nt for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of•property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or -improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed " pursuant to the Contractors' State License Law.). exempt under Sec. , B.&P.C. for this reaso Date: Q CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the . work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: Owner: MARK LADEA 55-075 MONROE LA QUINTA, CA 92253 Contractor: Owner VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 ------------------ WORKER'S COMPENSATION DECLARATION Date: 11/.27/07 I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is - issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, . and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: ✓YARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP.TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT ' MPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the :onditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the,work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. certify that I have read this application and state that the above information is correct. I agree to comply with all :ity and county ordinances and state laws relating to ^g construction, and hereby authorize representatives - )f this couryy to nter upon th o e-mend r or i spection purposes. Dater` s ��ignature pplicant or A nt): LQPtRIMIT Application Number . . . . 07-00001284 ------ Structure Information STABLE BLDG ----- Other struct info . . . . . CODE EDITION 01BMP04E05EN FIRE SPRINKLERS NO MIXED -USE OCCUPANCY U-3 OCCUPANT LOAD .00 PATIO SQ FTG 1957.00 1ST FLOOR SQUARE FOOTAGE ---------------------------------------------------------------------------- 5698.00 Permit . . . BUILDING PERMIT Additional desc 5698 SF STABLE BLDG Permit Fee . . . . 825.00 Plan Check Fee 536.25 �152524 Issue Date . . Valuation Expiration Date 5/25/08 Qty Unit Charge Per Extension BASE FEE 639.50 53.00 3.5000 THOU BLDG 100,001-500,000 ---------------------------------------------------------------- 185.50 ------------ Permit ELEC-MISCELLANEOUS Additional desc . Permit Fee . . . . 73.25 Plan Check Fee 18.31 . Issue Date . . . . Valuation 0 Expiration Date 5/25/08 Qty Unit Charge Per Extension BASE FEE 15.00 20.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 15.60 1.00 18.5000 EA ELEC SVC <=600V/<=200A 18.50 55.00 -.4500 EA ELEC DEVICE/FIXTURE >20 24.75 - Special Notes and Comments 5698 SQ. FT. STABLES WITH 1957 SQ. FT. PATIO..2001 CBC,2004CEC. U-3 OCC TYPE V-N CONSTRUCTION..NOTE:SEE PERMIT # 07-3026 FOR TRELLISED CARPORT. ----------------- r ------------------------- Fees . . . . . . . ENERGY REVIEW FEE 53,.63 STRONG MOTION (SMI) - COM 372.03 Fee summary Charged Paid Credited Due Permit Fee Total 898.25 .00 .00 898.25 Plan Check Total 554.56 250.00 .00 304.56 Other Fee Total 85.66 .00 .00 85.66 t Grand Total 1538.47 250.00. .00 1288.47 , LQPE%IIIT Y• Bin =�' =t City of La `Quinta \� - �- Building &r Safety Division APR l�� �� aP.O. Box 1* 504, 78-495 Calle Tamp, cam � La Quinta, CA 92253 - (760) 777-70'M � Building Permit Application and Tracking Sheer, 7A t Permit # 1 0 Z� ^n� -1 �I Pro jec Address: 55l) Owner's Name: i A.P.�Number: Address: Legal) Description: Co►:rtractor: Ow-nv.f" City, ST, Zip: p >.:#:: �::>'s<::�:>�<:>>::<:: Address: Project Description: C ty, ST, Zip: Sj ^� Telephone: o � :;:4'{'{:ii.iYi W:biin::::.::::•: • v:: •i:SW.:v :.� is a::>>:::<<:»z<::>;::t::<.:><::::<.::<<::'>>:::Gla _ State Lic. # : City Lic. #. Arch., Engr., Designer: N Address: e City., ST, Zip: Telephone: �i:4�: rif••,:: State Lic. # ::v>.:.><•;: ;.:::::.>< •: Name of Contact Person: �= \ n�o , _ Construction o Type: Occupancy: Project a (circle ' ) type ( le one): New Add n Alter Repair Demo Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: -7 Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING r PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit 50 Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. o ri jJt S Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbin Grant Deed Plans picked up I H.O.A. Approval Plans resubmitted Gra g IN HOUSE:- '"' Review, ready fo rections/is a velo r Im Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees y Jun 18 08 11:39a p.2 June 17, 2008 To: City of La Quinta Building Department Re: Building Permit # 07-1284 "The Stable" To Whom It May Concern: - - - - -- I, Charlie Sharhtour, approve and accept the structural engineering for "The Stable, located at 55075 Monroe St., La Quints; Ca 92253 _ r 3 1 t Re 0 "A R"' NI C.K E� II N i :N f 0 R P 0 R A 1 E, D December3, 2007 City of La Quinta Public Works Dept. 78495 Calle Tampico La Quinta, CA 92253 Attn:, Paul Goble Re: 55075 Monroe Street S7p'Q L- Dear Sirs: I hereby certify that the pad elevation for the above mentioned project is in substantial conformance with the approved Precise Grading Plan. The elevation is as follows: .As -Built Elevation: 473.3 Approved Plan Elevation: 473.3 Sincerely, Michael D. Hacker, PE OFESSIO CEO V D w � NO.55, r d EXP. 12.31-08 * S�q CIV\\ OF CP\\F 77-530 Enfield Lane Building E Palm Desert, CA 9221.1 (760) 360-6900 Fax (760) 360-6999 , www.hockerengineering.com 1!: Geo-Engineers cnd Geologists: November 30, 2007 Mr. Mark La Deda , 55-075 Monroe Street La Quinta, CA 92253 Subject: Compaction Test Report Z �, 55-075 Monroe Street La Quinta; California LCI Project No.: LP07332 780 N. 41; Street E! Centro, Ca 92243 i760) 370-3000 . r760! 337-8900 fax 77-948 Wildcat Drive Palm Desert. CA 9221 i760i 360-0665 17W 360-0521 fax Dear Mr. La Deda: Attached is a summary report of compaction tests made of fill within the building pad on the subject project site. Placement and compaction of fill soils were not observed by our firm. The compaction tests were made in conformance to In -place Density by Nuclear Methods (ASTM 2922 & D3017) on November 29, 2007. The test results are attached. LIMITATIONS The tests results summarized in this report present the moisture and density only at the locations and. elevations tested on the specified dates. The density testing was performed according to the ,generally accepted, geotechnical engineering standards of practice that existed in the County of Riverside at the time the report was prepared. No opinion is expressed as to the uniformity of the material, compaction, nor adequacy of the material to perform as intended. No guaranty or warranty of the contractor's work is made or implied. The test locations are. approximate, determined by -pacing and sighting from distinguishable field features. In doing our, work, we have relied .on topographic -and surveying, information provided by others.- Mark La Deda LCI Project No.:LP07332 Natural or imported soils (if any) at one foot or below existing pad grade, were not investigated or tested by our firm. No warranty is made as to the stability/density of these soils. With any manufactured product, there .are statistical variations in its uniformity and in the accuracy of tests used to determine its quality. As compared to other manufactured products, field placement of materials usually presents large statistical variations in its uniformity and in the accuracy of the test results. Thus, even with careful observation and testing, all parts of the constructed product may not comply with the job requirements. Therefore, our opinion means that there is only a statistical.ly-based probability that the densities obtained comply with the job requirements. This report .is issued with the understanding that the owner or his. representative has the responsibility to insure That this report is submitted to the appropriate governing agencies. Please review the test results and contact our office with any questions or comments. Sincerely yours, Land ark Consultants, Inc... Gre M. Chan a, P.E. Pri ipal Engineer ".'.c....ae.+sJ Landmark Consultants, Inc. Summary of Laboratory Tests Maximum Density - Optimum Moisture (ASTM D1557) Client: Mark La Deda Project Name:. 55-07$ Monroe Street Project No.: LP07332 Max. Opt. Mat. Density Moisture TYPe Description USCS (pcQ (%) 1 Olive brown silty sand 4 SM 112.0 9.5 .J Legend: FP: Finish Pad N: Nuclear Gauge P: Pass Landmark Consultants, Inc. Compaction Test Summary Client: Mark La Deda Project No.: LP07332 Project 55-075 Monroe Street Test of: House Pads &to r z t4d�e Y S 'r eahon� Y', ` VYt sLr �lahv Note Vest s yR tammt `�'{`C x t+ S'c�+, .fir 1 11/29/07 North side of pad 1 FP-1' 106.0 5.2 .112.0 95 P N 2 11/29/07 South side ,of pad 1 FP-1' 105.1 4.8 112.0 94 P N 3 11/29/07 West side of pad 1 FP-1' 104.0 18.5 112.0 93 P N FOR INSTALLATION IN STREET AREAS, A CLASS 100-E-100 SLURRY SHALL 24 DIAM. C.I. GRATE & FRAME BE USED IN LIEU OF COMPACTED ALHAMBRA FOUNDRY A-12001 OR APPROVED BACKFILL. A MIN. 3" A.C. EQUAL. ADAPT . AS REQUIRED FOR 'V' GUTTER AND SHALL BE PLACED OVER CURB & GUTTER INSTALLATION. SET RIM TO GRADE SLURRY. WITH PRECAST RISERS. BA COMPACT KFILL TO 907MIN. III= _ WITH TOP 12" COMPACTED TO 95% I- - —_ 48 DIAM. PRECAST MANHOLE CONE III=I I = 6" PVC DOWN DRAIN WITH FILTERED -__ COLLAR PER DETAIL, SHEET 2 —III— 5' MIN. 1 I I=I 6" DOME TYPE RATE ON INLET — —= PRECAST REINFORCED CONC, SLAB —III- I _ 4" CONCRETE SLAB (POURED IN PLACE) O00 °°° — EXTEND 6 INTO.�1NDISTURBED SOIL =I I=III °°° (CLASS 560-C-3250 CONCRETE) I=I ° I=I I - 48" PRECAST PERFORATED CONCRETE RING O -I I I p 11 _ 1" TO 1 1/2" WASHED ROCK —I (IIIIII A NON -WOVEN FILTER FABRIC PER SEC. O°O —_ III I—� 88-103 CAL. STD. ;SPEC. SHALL BE USED I'I I=III=I O —III: I I —III= BETWEEN THE WASNED ROCK AND O II °� UNDISTURBED SOIL I IIIII o 12" � =III=III (0) 8, a' 3 MIN. oO IIIIIII I '` I I —III= I o° =III=i DOZo =I I=III O° O° I I L=I I 1 " TO 1 1/2" WASHED ROCK ON '-I I I -I Q_ UNDISTURBED SOIL' A MINIMUM 12" THICK III=IIIJ Oc 00 III I OOoOOoO�oOOoU i OCR OCR nn nn["i n�i I I=1 I I=1 I I III I I.I=1 I I III I � 1=1 � 1= -�III� �Illllllllli i I Ii.� i hill II I I(IIII I III 1 NOTES: ALL JOINTS ABOVE THE LEACHING AREA SHALL BE MORTAR SEALED INSIDE AND OUT. MAX. PERCOLATION RATE = 1 "/HR, OR HALF OF AN ENGINEERED PERCOLATION TEST UP TO 5'/HR. MAX. THE SURFACE AREA FOR PERCOLATION MAY BE THE OUTSIDE AREA OF THE GRAVEL (6.�' DIAM.. TYP.) THE HIGHEST RUNOFF FROM A 100 YEAR FREQUENCY- STORM, NO MATTER WHAT TIME LgNGTH, SHALL BE UTILIZED WHEN CALCULATING THE STORAGE CAPACITY NEEDED IN A DRYWELL. STANDARD REVISIONS ;DETAIL DRYWELL DETAIL 306 APPROVED BY. CITY ENGINEER. DATE SHEET 1 OF 2 BAND n . ri. JA A n J (2) 6'f'VC PRESSED TG MAKE V SHAPE, REMOVABLE FOR CLEANING 6" P 0 PIPE WITH 1 " PERFoRA RON 5 DRILLED ® 2 "t 0. C. 6" DOME TYPE GRATE ON INLET WRAP PERFORATED SECTION WITH FILTER FABRIC THEN WRAP FABRIC WITH PROTECTIVE LAYER OF _ALUMINUM WINDOW SCREEN, OVERLAPPED AND HELD IN PLACE WITH ADJUSTABLE BAND CLAMPS. L j Q� O 4 " PRECAST REINFORCED CONC. SLAB PER SHEET 1 J 1 n w. J 1 n w ' v EPDXY PIPE INTO PRECAST CONCRETE STANDARD REVISIONS FIL TERED COLLAR FOR STANDARD DRYWELL DETAIL 3.06 APPROVED BY: CITY ENGINEER DATE SHEET 2 OF 2 �- TITLE 24 REPORT AJ . Title 24 Report for: Tally Ranch Stable 755075 Monroe Street La Quinta, Ca Project Designer: Desilva Architects 2901 Business Center Drive, Suite 210 Irvine, CA 92612 (949) 296-0103 Report Prepared By: James Terry Terry Engineering 13691 Red Hill Avenue _ Tustin, CA 92780 (7.14) 838-1124 CITY OF (A QUINTA BUILDING & SAFETY DEPT. APPROVED TERRY ENGINEERING FOR \ CONSTR C-nON DA �1:2 Ld7 BY►��'v - Job Number: 070222 C� Date: OCT 16 2007 7/17/2007 g The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program. developed by EnergySoft, LLC - www.energysoft.com. EnergySro 4.3 by EnergySoft Job Number: 070222. User Number: 2448 TALE OF CONTENTS Cover Page Table of Contents Form LTG-1-C Certificate of Compliance Form LTG-2-C Indoor Lighting Schedule Form LTG-4-C Lighting Controls Credit Worksheet Form LTG-5-C Indoor Lighting Power Allowance Form OLTG-1-C Certificate of Compliance Form OLTG-2-C Lighting Compliance Summary Form OLTG-3-C Illuminated.Area Calculation Worksheet Form LTG-MM Lighting Mandatory Measures Job Number: 070222 1 2 3 6 7 : 8-' 9 11 13 15 i User Number: 2448 CERTIFICATEOF COMPLIANCE (Part 1 of 4) LTG-1-C! PROJECT NAME DATE Tally Ranch Stable 7/17/2007 ROJECT ADDRESS 55075 Monroe Street La Quinta Building Permit # PRINCIPAL DESIGNER - LIGHTING TELEPHONE Desilva Architects (949) 296-0103 DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Terry Engineering ; (714) 838-1124 I EnforcementA Age use GENERAL INFORMATION ' DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 4-5-2007 0 sq.Ft. 15 BUILDING TYPE ❑ NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEUMOTEL GUEST ROOM ❑ CONDITIONED SPACES . ❑X UNCONDITIONED SPACES ❑ INDOOR & OUTDOOR SIGNS PHASE OF CONSTRUCTION ❑X NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION METHOD OF LIGHTING ❑ COMPLETE BUILDING ❑ AREA CATEGORY ❑ TAILORED ❑ PERFORMANCE COMPLIANCE ❑ COMMON LIGHTING i STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is acc and co DOCUMENTATION AUTHOR SIGNATURE DAT James Ter The Principal Lighting Designer hereby certifies that the proposed building &sign represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 130 - 132, 146; 148 & 149. of Title 24, Part 6. I i ❑ The plans & specifications meet the requirements of Part 6 (Sections 10-103a). The installation certificates meet the requirements of Part 6 (10-103a 3). I The operation & maintenance information meet the requirements of Part 6 (10-103c). i Please Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person j❑ responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. I I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and rofessions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Pr s de Sections 5537, 5538 and 6737.1. PRINCIPAL LIGHTING DESIGNER - NAME SIGNAT E C - DATE LIC. # 9 • 217.0`1 G-Z837701 Desilva Architects ( 42, LIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures LIGHTING COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included 19LTG-I-C, Parts 1 of 4 and 2 of 4: Certificate of Compliance. Part 1 of.4 and 2 of 4 are required for all submittals Ixl LTG-1-C, Part 3 of 4: RLTG-1-C, Part 4 of 4: jW LTG-2-C: !❑ LTG-3-C: In LTG-4-C: xl LTG-5-C: ,❑ LTG-6-C: 3 LTG-7: C: L LTG-8-C: �f LTG-9-C: Certificate of Compliance. Part 3 of 4 submittal is required only if Control Credits are claimed Certificate of Compliance. Part 4 of 4 submittal is required when lighting controls are installed Indoor Lighting Schedule Portable Lighting Worksheet Lighting Controls Credit Worksheet Indoor Lighting Power Allowance Tailored Method Worksheet Room Cavity Ratio Worksheet Common Lighting Systems Method Worksheet Line Voltaae Track Liahtina Worksheet EnergyPro 4.3 by EnergySoft User Number: 2448 Job Number: 070222 _ Page:3 of 15 CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG-1-� (PROJECT NAME . DATE Tally Ranch Stable I 7/17/2007 NSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES INSTALLED WATTS INSTALLED LIGHTING, CONDITIONED SPACES (From LTG-2-C) 0 PORTABLE LIGHTING (From LTG-3-C) 0 LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG-4-C) 0 CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG-2-C) 1,291 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG-4-C) 5 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 1,286 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG-5-C) ❑ AREA CATEGORY METHOD (From LTG-5-C) ❑ TAILORED METHOD (From LTG-5-C) ALLOWED LIGHTING POWER ALLOWED WATTS 0 ALTERNATE COMPLIANCE ❑ PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG-8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG-5-C 3,335 MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Dimming, etc.) Check if SPACE CONTROLLED Daylighting NOTE TO FIELD NOTES TO FIELD - For Building Department Use Only EnergyPro 4.3 by EnergySoft User Number: 2448 Job Number: 070222 Page:4 of 15 CERTIFICATE OF COMPLIANCE (Part 4of4) LTC -L PROJECT NAME Tally Ranch Stable DATE 7/17/2007 Designer: this form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type requires a test, list the equipment description' and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting system system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG-1-A, Forms shall be submitted to the building department that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of§10-103(b) and Title 24 Part 6. Test Description Test Performed BY: LTG-2-A: Lighting Control Acceptance Document Y L�' - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic -Time Switch Control Acceptance Equipment requiring acceptance testing ❑ LTG-3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance testing EnergyPro 4.3 by EnergySoft User Number: 2448 Job Number: 070222 Page:5 of 15 1 INDOOR LIGHTING SCHEDULE (Part 2 of 2) LTG-2-C (PROJECT NAME DATE Tally Ranch Stable 1 7/17/2007 pASTALLED LIGHTING POWER FOR UNCONDITIONED SPACES Luminaire Lamps/Ballasts Installed Watts __ _ -i— C D E F G H J i Name Type Description 333 Q NO vom �� r- 3 =mc (D O 9.G �m (p wm r c 303 • N _ �md x9» N 1) 24w/27w Lng Cmpt T5 Fluorescent n Elec FT24W 2G11 1 241 1.01 27.0 X 1 11 27 2ec ft Fluorescent T8 Energy Savings 3 30 1.0 79.0 X 1 121 948! 26W Recessed Flourescent Can Light 178LE 1 26 1.0 26.0 X'. 6, 156i 40w Wall Mount Incandescent 0W 1 40 40.0 X 4 160 I � i i PAGE TOTAL 1,291` BUILDING TOTAL (sum of all pages) 1 ,291s CONTROL CREDIT (From LTG-4-C) ' 5; ADJUSTED ACTUAL WATTS __. ,286` EnergyPro 4.3 by EnergySoft User Number: 2448 Job Number: 070222 Page:6 of 15 j LIGHTING CONTROLS CREDIT WORKSHEET (Part 2 of 2) LTG-4-C I L CREDITS FOR UNCONDITIONED SPACES ROJECT NAME DATE A B C D E I F I G H V J- ROOM # ZONE ID CONDITIONED AREAS LIGHTING CONTROL DESCRIPTION PLAN REF. ROOM AREA (SF) DAYLIGHTING WATTS OF CONTROL LIGHTING LIGHTING ADJUST. FACTOR' CONTROL CREDIT WATTS (H X I) WINDOW WALL RATIO GLAZING VLT SKYLIGHT EFFECTIVE APERTURE ' Storage Occ Sensor - <= 250 sgft 64, 261 0.20 5. i I I ' I - I I 1 From Equation 146-A 2� From Table 146-A PAGE TOTAL BUILDING TOTAL 1-- 5-1 Enter in LTG-2-C: Lighting Control Credit EnergyPro 4.3 by EnergySoft User Number: 2448 Job Number: 070222 Page:7 of 15 INDOOR LIGHTING POWER ALLOWANCE LTG-5-C PROJECT NAME Tally Ranch Stable DATE 7/17/2007 LL,OWED LIGHTING W C oose One Method) COMPLETE BUILDING METHOD - CONDITIONED SPACES WATTS PER SF COMPLETE BLDG. AREA ALLOWED WATTS BUILDING CATEGORY (From Section 146 Table 146-B) AREA CATEGORY METHOD - CONDITIONED SPACES AREA (SF) ALLOWED WATTS AREA CATEGORY (From Section 146 Table 146-C) WATTS PER SF PAGE TOTAL BUILDING TOTAL AREA WATTS TAILORED METHOD - CONDITIONED SPACES TOTAL ALLOWED WATTS (From LTG-6-C or from computer run.) UNCONDITIONED SPACES Complete Building and Area Catagory Methods Category (From Section 146 Table 146-B&C) WATTS PER SF AREA (SF) ALLOWED WATTS All Others 0.60 5,494 3,296 Commercial, Industrial Storage 0.60 64 38 PAGE TOTAL BUILDING TOTAL 5,558 3,335 5 558 AREA 3 335 WATTS TAILORED METHOD - UNCONDITIONED SPACES TOTAL UNCONDITIONED SPACES ALLOWED WATTS (From LTG-5-C and LTG-6-C) 0 EnergyPro 4.3 by Enerq ySoft User Number: 2448 Job Number: 070222 Page:B of 15 CERTIFICATE OF COMPLIANCE (Part 1 of 2) OLTG-1-C PROJECT NAME DATE Tally Ranch Stable 7/17/2007 'ROJECT ADDRESS 55075 Monroe Street La Quinta Building Permit # PRINCIPAL DESIGNER - LIGHTING TELEPHONE Desilva Architects (949) 296-0103 DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Terry Engineering (714) 838-1124 Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS OUTDOOR LIGHTING ZONE 4-5-2007 LZ1 LZ2 0 LZ3 LZ4 FUNCTION TYPE FX-1 OUTDOOR LIGHTING OUTDOOR SIGNS INDOOR SIGNS PHASE OF CONSTRUCTION ® NEW CONSTRUCTION ADDITION O ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the outdoor lighting system specifications need to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNATURE DAT James Ter17117L07 The Principal Lighting Designer hereby certifies that the proposed outdoor lighting and signs design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 130 through 132, and 146,and 149 of Title 24, Part 6. please Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. ❑ I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE DATE LIC. # Desilva Architects LIGHTING COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included (ROLTG-1-C: Certificate of Compliance. Required on plans for all submittals for outdoor lighting. Part 2 of 2 may be incorporated in schedules on the pl Either LTG-1-C or OLTG-I-C may be used for signs as follows: 1. Use LTG-1-C if the project consists solely of indoor signs. 2. Use LTG-1-C if the project consists of indoor lighting, outdoor or indoor signs, but no other outdoor lighting. 3. Use OLTG-I-C if the project consists solely of outdoor signs. 4. Use OLTG-1-C if the project consists of outdoor lighting, outdoor or indoor signs, but no other indoor lighting. ®OLTG-2-C: LIGHTING COMPLIANCE SUMMARY. Applicable parts required for ALL outdoor lighting allowances (Except Signs). 70LTG-3-C: AREA CALCULATIONS WORKSHEET. Applicable parts required for all outdoor area calculations. AOLTG-4-C: SIGN LIGHTING COMPLIANCE. Required for all internally and externally illuminated signs, for both indoor and outdoor signs. EnergyPro 4.3 by EnergySoft User Number: 2448 Job Number: 070222 Page:9 of 15 ins. CERTIFICATE OF COMPLIANCE (Part 2 of 2) ®LTC -1-C PROJECT NAME DATE Tally Ranch Stable 1 7/17/2007 .ighting Schedules on Plans Show that Outdoor Lighting Meets Allowed Lighting Power ❑X ❑ Lighting power allowance for general site illumination on OLTG-2-C Part 1 of 4 Not Applicable ❑ ❑X Lighting power allowance for local ordinances or for security multipliers on OLTG-2-C Part 2 of 4 Not Applicable ❑X ❑ i Lighting power allowances for specific applications, other than vehicle service stations with canopies on OLTG-2-C Part 3 of 4 Not Applicable j ❑ ❑X Lighting power allowances for vehicle service station canopies on OLTG-2-C part 4 of 4 Not Applicable ❑X ❑ Sign lighting compliance on OLTG-4-C Not Applicable ' I Mandatory Measures on Plans Show that Outdoor Lighting Meets Outdoor Lighting Controls And E ui went ❑X ❑ Installed lighting power has been determined in accordance with Section 130(c)1 Not Applicable ❑ ❑X All permanently installed luminaires with lamps rated over 100 Watts either have a lamp efficacy of at least 60 lumins per Watt or are controlled by a motion sensor per Section 132(a) i Not Applicable ❑ ❑X All Luminaires with lamps rated greater than 175 Watts in hardscape area, including parking lots, building entrances, canopies, and all outdoor sales areas meet the Cutoff Requirements of Section 132(b) Not Applicable _X 1 i All permanently installed outdoor lighting meets the control requirements of Section 132(c)1 Not Applicable ❑ Building facades, parking lots, garages, canopies, and outdoor sales areas meet the Multi -Level Lighting Requirements of Section 132(c) Not Applicable MANDATORY AUTOMATIC CONTROLS ( I AREA CONTROLLED NOTE TO FIELD CONTROL LOCATION (Room aY) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Dimming, etc.) j II i i EnergyPro 4.3 by EnergySoft User Number: 2448 Job Number: 070222 Page:10 of 15 LIGHTING COMPLIANCE SUMMARY (Part 1 of 4) ®LTG-2-� (Project Name Date Tallv Ranch Stable 7/17/2007 LIGHTING POWER ALLOWANCES - GENERAL SITE ILLUMINATION - Table 147-A Allotted Watts Luminaire Lamps/Ball sts Installed Watts A B C D E F G H I J K L M N, O Lighting Application Category (Table 147-A) r D p T .x D rw + $ D M xa m o p Description O m r c 3y c m C3 c 3.N d a W 0 m n c — rc Zo a.3 dm y° x.7ya . �omoy ?� 0 Right Entrance 50 0.70 353 60w Wall Mount Incandescent X 60W 1 60 1 60.0 X 180 I I _ I. J f Total Allotted Watts 353 F-I Total Installed Watts 1801 EnergvPro 4.3 by EnergySoft User Number: 2448 Job Number: 070222 Page:11 of 15 1 LIGHTING COMPLIANCE SUMMARY (Fart 3 of 4) ®LTG-2-C Name Tally Ranch Stable Date 7/17/.2007 LIGHTING POWER ALLOWANCE FOR SPECIFIC APPLICATIONS Table 147-B - Other than Vehicle Station without Canopies Allotted Watts i Luminaire Lamps/Ballasts Design Watts A a C D ! E F �G H I I J K L M N 1 O P Lighting Application Category (Table 147-B) r D m � d a x D �o ?x� mar 0 v. D o �� a c1 x w n $ 0 Description p y LA. 0 0; r m •0 3 m y I r ;c d 2.3 N a, 0 m r» 3 in 0 c m 3 d �» "•v A c `l 3,x m m, 0 '; - m f1 p » ;y ~ r 1 e eI 3 3'r*» Cr ° - g x m m I z H m 1 0 3D g o o m pa x Rear Wall 1,110 0.35 388 40w Wall Mount Incandescent X 40W 1 40 40.0 X 1 61 240 24� Front Wall 1,110 0.35 388 (1) 24w/27w Lng Cmpt T5 uorescent-Iwin_Bpa 1 24 1.0 27.0 X 1 27 26 40w Wall Mount Incandescent X 40W 1 40 40.0 X 6 240 Left Entrance 67 0.35 237 (1) 24w/27w Lng Cmpt T5 Eluoresce.nt Tw*n Ele_ 1 24 1.0 27.0 X 2 87 60w Wall Mount Incandescent X 60W 1 601 60.0 X 1 60 EnergyPro 4.3 by EnergySoft User Number: 2448 Job Number: 070222 Page:12 of 15 ILLUMINATE® AREA CALCULATION WORKSHEET(Part 2 of 5) ®LTC -3-C PROJECT NAME Tallv Ranch Stable DATE 7/17/2007 Hardsca a Method ii Hardsca a for driveways, site roads, sidewalks, Walkways and bikeways A B List Specific Application (Table 147-A) Length of 25' wide path incorporating as much of he paved area as possible. Checklist ❑ Section 147 (c)1 B - Each portion of all illuminated areas has been assigned only one lighting application, and the applications are consistent with actual use of the areas. ❑Section 147 (c)1 B Method ii - General illumination areas for site roadway, driveway, sidewalk, walkway, or bikeway includes only those illuminated areas that are in the bounds of the Application and includes a 25 foot wide area runnin along the axis of the path of travel and much of the paved area as possible. B. Building Entrances without Canopies A B C Width of Door plus 3 feet on each side Smaller of 18 ft or distance to the edge of the property line Area (sf) (A x �) 28 18 504 Checklist ❑Section 147 (c)1 B - Each portion of all illuminated areas has been assigned only one lighting application, and the applications are consistent with the actual use of the areas. Section 147 (c)1 A.- General illumination areas includes only those illuminated areas that in the bounds of the Application and are with a square pattern around a luminaire that is six times the luminaire mounting height, with the luminaire in the middle of the pattern, less any areas that are within buildings, under canopies, beyond property lines, or obstructed by a signs or other structures. EneravPro 4.3 by EnergvSoft User Number: 2448 Job Number: 070222 Page:13 of 15 1 ILLUMINATE® AREA CALCULATION WORKSHEET(Part 3 of 5) ®LTG-3-C PROJECT NAME DATE Tally Ranch Stable i 7/17/2007 ►. Outdoor Sales Lot Frontage and Sales Lot Area A B C D E F G H Gross Illuminated Area (sq. ft.) If an Outdoor Sales Frontage Allotment was used, subtract that area from the Gross Illuminated Area Overlapping Areas of Another Application Sales Lot Area (A - F - G) Mounting height of Sales Frontage Luminaires (feet) 3 x B Distance (In plan view) from the frontagge luminaire to front edge of Sales Lot Sales Lot Frontage Length (feet) Sales Frontage Area (C - D) x E (sq. ft.) I 1 j i I � I ❑ Section 147 (c)1 B - Each portion of all illuminated areas has been assigned only one lighting application, and the applications are consistent with actual use of the areas. ❑ Section 147 (c)2 B - Measured in plan view, only illuminated sections of outdoor sales frontage areas that are immediately adjacent to the principle viewing location and unobstructed viewing length, and are within 3 mounting heights of the frontage have been used. Luminaires qualifying for this allowance are located in plan view between the principle viewing location and the frontage sales. 3. Building Facade Area A B C D E F G H Designated Name and Orientation Length Height • Gross Area (B x C) Areas (SF) to Subtract from within the Illuminated Area j Net Area Available for Facade Ligghtin (D -G � Areas covered by signs Area for which Illumination is Obstructed by Other Objects and Area Not Illuminated Sub total (E + F) Rear Wall 96 12 1,110 0 0 1,110 Front Wall 96 12 1,110 0 0 1.110 Left Entrance 59 12 678 1 1 0 1 0 678 l I -T i � i t 1 I I I I i i Checklist ❑ Section 147 (c)1 B - Each portion of all illuminated areas has been assigned only one lighting application, and the applications are consistent with actual use of the areas. ] Section 147 (c)2 A - Only facades areas that are illuminated without obstruction or interference, by one or more luminaires, have been used. I EnergyPro 4.3 by EnergySoft User Number: 2448 Job Number: 070222 Page: 14 of 15 LIGHTING MANDATORY MEASURES LTG-MM PROJECT NAME DATE Tally Ranch Stable 7/17/2007 DESCRIPTION Designer Enforcement ® §131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. §131 (d)2 Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square .feet. ® §119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. ® §111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. ❑ §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are _ specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. ® §131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to - ceiling walls. §131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. §131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.3 by EnergySoft User Number: 2448 Job Number: 070222 Page:15 of 15