4393-_ROTE �� •�
With proper validation '
this form. -constitutes an CITY OF: LA QUINTA
encroachment permit.
APPLICATION FOR PERMIT*
PUBLIC WORKS CONSTRUCTION (ENCROACHMENT)
For the construction of public or private curbs, driveways, pavements, sidewalks, parking lots, sewers, water mains
and other like public works improvements in connection with MINOR IMPROVEMENTS and APPROVED SUBDIVISIONS
Subdivision Improvement Permit —Class I
DATE: Agpy .4 ?nn% Minor Improvement Permit Class IV
LOCATION OF CONSTRUCTION 51-480 C€tlle Hueneme
(Street.address or Description of Location) .
PURPOSE OF CONSTRUCTION 0 Service installation. Sketch (attach construction plans if appropriate):
(domestic)
DESCRIPTION OF CONSTRUCTION
DIMENSION OF INSTALLATION OR REMOVAL
SIZE OF"EXCAVATION, IF NEEDED
APPROXIMATE TIME WHEN WORK WILL BEGIN Yla; 9, 2005
APPROXIMATE TIME OF COMPLETION 9. 2005 !
ESTIMATED CONSTRUCTION COST $
(Including removal of all obstruction, materials, and debris, backfilling, com-
paction and 'placing,permanent resurfacing and/or replacing improvements)
In consideration of the granting of this permit, the applicant hereby agrees to:
Indemnify,. defend, and save the City, its authorized agents, officers, representatives and employees, harmless from and against any and all
penalties, liabilities or loss resulting from claims or court action and arising out of any accident, loss or. damage to persons or property
happening or occurring as a proximate result of any work undertaken under the permit granted pursuant to .this application..
Notify the Administrative Authority at least twenty-four (24) hours in advance of the time when work will be. started.
Comply with all applicable City Ordinances, the terms and conditions of the permit and all applicable rules and.regulations of the City. of
La Quinta and to pay for any additional replacement necessary as the result of this work.
Signature of Applicant or Agent
a2 ^ , (! [Pn9 1 wv T7.aP sa Yli atri nw P0 unx i t15A rnnnhal taa 6"A 760 398 2651
Name of Applicant (please print) Business Address Telephone No.
Same
Name of Contractor and Job Foreman Business Address Telephone No.
N/A N/A
Contractor's License No. City Business License No.
' Seii—itar�ured '
Applicant.'s'�lnsurance Company Policy Number
" `FEES:.. Subdivision] mprovement Permit — Class III
Public improvements: 3% of estimated construction costs --
`. Private improvements: 3% of estimated construction costs. E
Minor. Improvement Permit — Class IV: See attached schedule N�P.�'r
. 4393 �� o
Inspection Fee . $ NO Fee PERMIT VALIDATION
Permit'Feea.;.�
PERMIT NO.
Penalty,
Cash Deposit -Surety Bond
if required
TOTAL: $ No Fee
Receipt No.
Received by
Date j
•DATE APPROVED J
EXPIRATION DATE
DATE`ISSUED t`,j��\\•��� "
By
Administrative Authority
Telephone: (760) 777-7075
�i
Recorded.by
}
e
NOTE:
With proper validation
this form constitutes an CITY OF LA QUINTA
'encroachment permit
APPLICATION FOR PERMIT
PUBLIC WORKS CONSTRUCTION (ENCROACHIl NI
For the construction of public or private curbs, driveway.s, avemer� , s de alks,'
P � I
and other like public works Improvements In connection with MINOR I(VIP�(O E EN S
DATE: 4 �' OS
LOCATION OF CONSTRUCTION
(Street address or.Descrlption of Location)
PURPOSE OF CONSTRUCTION Sew
7
DESCRIPTION OF CONSTRUC ION
DIMENSION OF INSTALLATIOAOR RE O L -�
jj'lots, sewers, water mains
APPROVED SUBDIVISIONS
Ivin Improvement Permit— Class I II
nor Improvement Permit Class IV
a
(Sketch (attach construction plans if appropriate)
SIZE OF EXCAVATIQPd 10 N E % \ LJ C)
APPROXIMATE TJ N 0 K LL BEGIN `.
APPROXI ATE I E F OMPLETION
ESTIMAT D ftS R TI N COST $ u
(lnclufling r movaj f all 'struction, materiels 9n3•d6b\is, kkfiflllirq , com-
p cilon\\.and lac�g permanent resurfacing d/ r�rep d ng� prbrvementsl
Inc sideti n of the, granting of this pe mi , th ep II anhereby agrees to:
emnifk efend and save the City, Its a th ad go to, officers, representatives and employees, harmless from and against any and ell
ng ie'/�jlabllitles or loss resulting from la; A c rt action and arising out of any accident, loss or damage to persons or property' \
pen ng or occurring as a proximate resul of any ark undertaken under the permit granted pursuant to this application.
btify the Administrative Authorlty at least twlrK V-four (24) hours In advance of the time when work will be started.
'Comply with all applicable City Ordinances, the terms and conditions of the permit and all applicable rules and regulations of the City of
Le Quints and to pay for any additional replacement necessary as Qre result of thiswork. '
Name of Applicant (please print) Business Address Telephone No.
.Name of Contractor and Job Foreman Business, Address r (� Telephone No.
V rn
Contractor's License No.' City Business License No.
Applicant's Insurance Company Policy Number
FEES: Subdivision Improvement Permit — Class Ill
Public Improvements: 3% of estimated construction costs
' Private Improvements: 3% of estimated construction costs
Minor Improvement Permit —Class IV: See attached schedule
Inspection Fee $ PERMIT VALIDATION.
Permit Fee PER N0. 3 `
Penalty
Cash Deposit -Surety Bond DATE APPROVED
if required EXPIRATION DATE
TOTAL: $ IU O Fe
DATE ISSUED
Receipt No.
By
Received by Date Administrative Authority
Recorded by Telephone: (760)777-7075
r
111
104
087
/239
78-235
"451-315
a
51-320
(U
n
0-
103
088
%
112
��
0
L 51-325
51-310
W
Q
Q`
89
Q102
51-360
Q
101
090
CALLE CADIZ
�
51-400
t"
238
113
100
091
78-231 '-' 51-401
n
w
114
01
099
092
115
`
098
093
237
M
^
J
517450
0
.�
51-445
_
o
J
t^u
Q
097
094
116
N
U
51-470
51-465
095
117
r 096
51-485
78-270
51-485
T
nv�niinn
cLuB_/.
0.2
dw
080
51-296 N d
063
io
i
056
51-412
039
51-335
(U
A
A
W
%DI
�
z
079 0-1055
0
040
W
51-300 (U U)
51-355
51-414
N
51-355
=
078
065
054
0N
041
-'
Milk
51-375
51-416
51-365
077 00
066
053
16.0f
042
+
51-360 .-�
r
51-395
00.n
51-385
.
076
00
067
052
00
043
51-405
51-420
51-405
co (-
,�
0
o
N
075
068
051
044
51-400 "0
ON
-
N
51-415
N
N
v
of
074
0
069
050
Lr)
0
045
^�
51-455
W
51-422
n
(Nu
Q
049
d
y
-Pz73± �� 070 i
046
.!.•
.ZI
51-475
071
51-495
U
51-460
048
51-480
N 047 #—F
.-a —
1
i
(22708)
7-
6' :•DIP-98
N U ESTRA
op:
R
239 111 CD 104 087 w 080 063 �D 056 j 1 uac 039
51 5i 51-3151-315 0/78-235 5131-33a A
A W O
112 %D Q 103 0 088 z 079 0 064 J_ 055 0Lr) 040 031 c
_7 51-310 N W 51-300 N 51-355 51-414 N 51-350 R
51-325 Q 51-355
102 GN 089 T 078 065
Q I0 0�
054 0� 041 030 ' 0
51-360 '-' 51-375 51-416 �5i__365 m 51-380
Q
101 090 077 066 029
CALLE CAD Z C� 51-400 I, 51-36000
. 51-395 UL)053 p42 a
238 113 ,� I, 51-385
78-231 '-' 51-401 100 n W 091 076 067 052 043 028 r
51-405 51-420 -+
51-405 QD
114
c�
092 075 068 •cu
027N -051=420� 51-400 n
-I . (U 1-415of cu
115 098 Y) 0 093 074 Y) 0 069 050 Uo 0 045 J 026 Lr
237 m ^� LLJ 51-450 .-� .� 51-445 ^ .� ti 51-455 W —
J Q - -- J 51-422 J
cu Q 097 094 N.
070 I 046 U
116 N d N Q 049 .-, 025
U 51-470 .� .. 51-465 51-475 U
d r , 51-460
095 + ' 071
M N .. M1 048 ('7 047 024
117 - 78 270� '-' S1-485 51-495 ; 51-480
K.k
. '"i y V. e •may
51-485 '" _^6 •.DIP-98 _ - �— C22708)
T AVEN I DA N U ESTRA T
CLUB
0.2
t
(22861
.-- _ C22862)
9 0 /EST'
24 .�
Z/tz v v 14 IJ
R
WIW �I? oIN AID �rU IJ ?rU Ico IDJO
�. 4I� �ro Io JL
Q� J �rWAJ,�'
�\N� r
239 111 W104 087 w 080 r, 063 �b ` 056 j uac
m `r t W 51-296 O ,t 039 — a i 51-310
7 8 - 2 3 5 .1' 51-315 d 51-320 (U I (U 51-335 J 51-412 (U Q
i
112 Q 103 0 088 w z 079 0 064 - JO 055 0 040 +� oil,c
J 51-310 N W 51-300 N 51-355' 51-414 N { 51-350 (L
� 51-325 Ho I Q 51-355 ,
102 ON 0089 2 078 065 054 0' 041 030 ' 0'
51-360 '-' 51-375 51-416 51-365 m 51-380
Q
CALLE CADIZ 101 090 077 066 ; 053 042 029
U 51-400 W � 51-360 r 51-395 I� 51-385 () Q
238 113
78-231 '-' 51-401 100 091 076 067 052 043 i 028
Vj 51-405 51-420 OD r
51-405 CD
r' 114 ^
N 099 092 075 068 0 051 044 N 027
I'0 ON 51—.400 0 a"(U� � 51-415 , cu 51-420 �
(U
v
115 ^) 098 0 093 074 LO 0 069 050 LO 0 045 J 026
Lr
237 Ljj 51-450 �-� r+ 51-445 ,� ,-4 —
o J o Q 51-.455 J 51-422
cnu Q 097 094 a y � 73 `: 070 1 Q 049 U 025
116 cu d N .� d -� 046 d
.. U 51-470 .� .-� 51-465 .. x .-+ '� 51-475 ! . U 51-460
r
. 4047095• 8 24
51-495 51-4096 M (l(U 0
117 51-485
i
In 78-270 y , c� �:
51-485 6'DIP-98 C22708) �-
7L
T AVEN I DA N U ESTRA T
CLUB
0.2
(22861 C22862)
$WEST-`�.�
o
-4
WN ODN OVDN �N OD N W Iru 14 W
wiW �I- olCA �I� NIv �Iw .0, Alo 1,0�
OD r r r �, ►w+ N 0�
I T'o r
w\� 8 7 6 S 4 3 2 1
(a 0 70 G 3
239
:
111
a)'
104
087
m
080
063
t0'
`
0561-4
.�
039
78-235
51-315
I
51-320
(U
a
W
51-.296 nj
51-335
J
51-412
(U
A
A
W
112
0
0
%o
Z
0790
Ln
064
O103
055
0
040
51-325
51-310
N
W
51-300 N
53
1
51-414
N
51 5
3�
Q
Q102
Q�
,D
089
=
078 O
065
054
0N
041
51-360
�'
51-375
51-416
51-365
Q
,
CADIZ
—101
090
(
077
coU
0636
053
042CALLE
51-400
OD
51-360 .4
r
51-9 5
51-385
238
113
"
78-231
51-401
100
091
076
067
052
043
51-405
f
51-420
51-405
'DI
0o
i—
r'
N
114
n
N
099
092
075
068
051
044
I
51-.400
cu
•-,
51-415
••
cu
v
,
115
098
093
4
o069
050
0
045
237
�
Lli
51-450�51-445
no
51-45J-42
o�J
cu
Q
N
Q
i
Q
049
097
094
a j :'
!
070
046
116
cu
..
(�
= 51-470
d
.-�
..
51-465
cu .
...
i:;... ..
f
.51-475
I
U
51-460
—
:. '
117
..096
.095
51-485
a k�;
"
071
51-495 ;
048
51-480
(")
r.
047
i
z�
78-270
+�
�,
..
51-485
T
C LU-B
0.2
wt~ nl I n4
6'DIP-98 (22708) -j-
N U ESTRA
/:
00
Q
PERMIT NO.4393
CVVWD [New 1" Service Domestic Water / 51-480 Calle Hueneme
In addition to the standard permit conditions, the following shall apply:
1. Pursuant to Section 14.16.320 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), all
work shall be performed in accordance with the latest edition of the Standard Specifications For Public
Works Construction (SSPWC) and as directed by and to the satisfaction of the City Engineer.
2. CVWD , hereinafter referred to as "Permittee", shall be responsible for providing'continuous dust and
erosion control.
3. This permit or copy of it shall be on the work site for inspection during the actual work performed.
4. The permittee shall be responsible for calling the city inspector to arrange the city inspector to observe.
random trench compaction testing performed by a city approved material testing firm. If the inspector's,
phone number is unknown, the.permittee shall call the Public Works front counter phone at 777-7075 or
the Assistant Engineer I at 777-7089 to determine the city inspector's phone number. The inspector shall
determine the number and location of the test location/s. The 'above testing does not relieve the:
permittee's responsibility for future repairs due to settlement at and near the locations of the work area.
Materials testing must be performed under direct supervision of a California Registered Civil Engineer.
5. If public traffic lanes are required to be closed; this permit is not valid until the permittee submits, to the
Public Works Department; an approved traffic control plan at least 2 weeks prior to start of construction
or parking on the paved R/W.
6. Streets shall be kept clean.. They, shall be completely cleaned at the end of each, working day and more
frequently, if required.
1. Pursuant to. Section 6.08.050 of the La Quinta Municipal Code (Ordinance 18 § 1,1982), throughout the
work site, the Permittee shall comply with City regulated work hours. Operation and maintenance of
equipment within one-half mile of human occupancy shall be performed only during the following time.
periods: ,
October 1st to April 30: Monday -Friday 7:00 a.m. to 5:30 p:m.
Saturday 8:00 a.m. to 5:00 p.m.
May 1st to September,30: Monday -Friday 6:00 a.m. to 7:00 p.m.
Saturday 8:00 a.m. to 5:00 p.m.
Work shall be prohibited on legal holidays and Sundays.
Note: Construction work (including setting up traffic control devices) is not permitted on any Arterial
street (ie any 4 lane street) before 8:00 a.m.
Special Conditions Page I of 5
PERMIT NO:" 4393
CVWD / New 1" Service Domestic Water /'51-480 Calle -Hueneme
8.' Work.within 500 feet of a signalized intersection shall be performed between the hours of 9 a.m. 3
p.m. Traffic control shall be set up after 9 a.m. and removed before 3 p.m. The Permittee shall contact
the Riverside Country Traffic Signal Maintenance Department at (909) 275-6894 if signal operation at
the intersection is to be altered in any way.
9. Pursuant to Section 14.16.110 of the La Quinta Municipal Code (Ordinance 10 § 1 (part); 1982),
Permittee shall assume responsibility for repair of any pavement damage to any public or private street
and for any damage to other City streets or facilities as a result of work performed under this permit.
10.: Pursuant to Section 14.16.250 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982),
advance warning signs and traffic control shall be installed and maintained in accordance with Cal
Trans Standards or the Work Area Traffic Control Handbook (WATCH Manual). A traffic control
plan shall be prepared in accordance with the WATCH Manual and submitted to the City for
review and approval one (1) week prior to starting any construction. It shall be the Permittee's
responsibility to appropriately detour and barricade all construction sites.
Pursuant to Section 14.16.290 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), street
closures shall not be permitted. A minimum oftwo (2) travel lanes of paved surface shall be
maintained at all times.
11. Prior to excavating, if required, the Permittee shall contact Underground Service Alert at 1-800-422-
4133. It shall be the Permittee's responsibility to notify the Public Works Department of anticipated
excavation which impact City facilities; including but not limited to traffic signal conduits and loops,
irrigation .lines, electrical conduits, and storm drain facilities.
12. Should additional work, materials, or modifications of the work be required in order to meet City
standards, safety requirements, signage requirements, or to fit actual field conditions, the work shall be
performed by the Permittee as directed by and to the satisfaction of the City Engineer at no cost to the
City of La Quinta.
13. Pursuant to Section 14.16.370 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982),
backfill compaction within street rights -of -way shall conform with Section 306-1.3 of the latest edition
of the Standard Specifications For Public Works Construction (SSPWC), except as otherwise specified
herein.
Native material may be used as backfill material provided that minimum compaction, achieved in the
manner prescribed herein, is achieved. Backfill shall be performed by mechanical means; no water
densified compaction via jetting or flooding or other means shall be allowed. It shall be the Permittee's
responsibility to provide appropriate geotechnical supervision, testing, and inspection, onsite, at all
times during backfill operations.
Special Conditions Page 2 of 5
PERMIT NO.4393
CVWD / New 1" Service Domestic Water / 51-480 Calle Hueneme
Backfill compaction shall be achieved by the following conditions:
A. When a firm foundation is not encountered due to soft, spongy or other unsuitable material, such
material shall be removed to the limits directed by the Geotechnical In and/or. the City
Inspector and the resulting excavation backfilled with pipe bedding material.
B. Backfill materials shall be brought to or maintained at appropriate moisture content .for
compaction. The appropriate moisture content range shall be established at the onset of the
project and ensured prior to use of the materials through'progress testing on the stockpiles.
C. The first length of trench backfilled shall be backfilled in the presence of the City Inspector.
Compaction shall be tested at random depths at approximate three-foot vertical intervals as
backfill is placed to ensure the effectiveness of the compaction methods and to establish the depth
of lift that can be compacted.
D. If lifts greater than one foot are attempted in this trial length of trench, compaction tests shall be
taken within the lifts to ensure that the full depth of the lift is compacted. Upon satisfactory
completion of this portion of trench, the City Inspector shall establish the maximum lift thickness
to be compacted for the remainder of the project.
E. In subsequent lengths of trench, the frequency of compaction tests shall equal one per each lift of
backfill, per 300 linear feet of open trench, at randomly selected locations within the open length
of trench.
F. The depth of the randomly selected compaction tests shall also be randomly selected except that
where multiple tests are required in a given length of trench, the tests shall be no closer than three
feet (vertically) from each other.
G. If any compaction test fails, previously placed backfill (in the same length of open trench or
previous lengths of trench) which is represented by the failing test (as determined by the City
Inspector), shall be tested for compliance with compaction requirements.
H. All costs incurred due to the conditions above shall be borne by the Permittee. Copies of all test
results shall be furnished to the City Inspector.
14. All excavations within City of La Quinta right-of-way shall be backfilled; and temporarily paved if
within the existing travel way, at the end of every workday as directed by and to the satisfaction of the
City Engineer for the protection of the public. Lengths of open trench shall not greatly exceed that
which can not be backfilled in the same day. Excavated trenches shall not be allowed open overnight,
however, Permittee may leave a length of excavated trench, not to exceed twenty (20) feet in length,
open overnight at a point where construction will begin the next day, provided that this. length of trench
is completely covered by steel plating..
Special Conditions Page 3 of 5
:f
PERMIT NO.4393
CVWD / New 1" Service Domestic Water / 51-480 Calle Hueneme
15. All landscaping, irrigation, decorative rock, decorative concrete, lighting, etc., shall be replaced to its
original condition.
16. Access and egress to all local properties•shall be maintained at all times.
17. Pursuant to Section 14.16.375 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982),
permanent pavement replacement shall be completed no later than seven (7),days after the completion
of the work. Permanent pavement replacement shall conform to the following conditions:
A: Existing asphalt concrete pavement shall be sawcut one (1) foot beyond trench edges. Edges shall
be straight and clean.
B. Permanent pavement replacement structural section, within all trenches, shall be 1" thicker than
existing of asphalt concrete over the same existing thickness of crushed aggregate base or crushed
miscellaneous base, meeting the requirements of Sections 200-2.2 and 200-2.4 of the Standard
Specifications for Public Works Construction: The replaced pavement and base material shall be
compacted to 95% relative compaction and respectively tested, for each 300 linear feet of trench.
Verify exact structural replacement section thicknesses with the City prior to installation.
C.' Permanent .pavement replacement shall be installed using a City approved 3/4" max medium'
asphalt concrete. as the base course lift and a City approved %Z" max medium finish course lift for
capping. Asphalt concrete mix design shall be approved by the City prior to its placement.
D. Cold -Mill and Overlay = The existing pavement which was properly protected in place during the
trenching operation located adjacent to the trench saw cut shall be cold -milled to a depth of 0.10
feet with butt joint created next to the existing unmilled pavement surface.. The cold -milled area
and base asphalt -concrete in the trench area shall be overlaid with a City approved C2-AR-4000
asphalt concrete mix. The width of the cold milling area shall be as•follows:
• For longitudinal trenches located in a parking lane: three' Q) feet outside' the sawcut
removal lines.
• For longitudinal trenches located in a traffic lane: three (3) feet outside the sawcut removal
lines, or to the lane line.striping, whichever is greater.,
• For transverse trenches across existing street: two (2) feet outside the sawcut removal lines.
E. If grinding and capping operations are not performed in the same day as base paving operations,
.the base course lift of 3/4" max medium asphalt concrete shall be installed from saw -cut edge to
saw -cut edge flush with the existing street surface. The base course lift of paving shall not be left
0.10' low in anticipation of grinding and capping.
F. Any existing lane striping or any existing detour_ lane striping affected by this resurfacing shall be ,
replaced in kind by the Permittee, as directed by and to the satisfaction of the City Engineer.
.Affected traffic signal loops shall be, removed and replaced in kind. The finished pavement
surface shall be smooth, consistent, and shall conform to the surrounding grades.
Special Conditions Page 4 of 5
PERMIT NO.4393
CVWD '/ New 1" Service Domestic Water / 51-480 Calle Hueneme
18. Permittee shall permanently stabilize any and all soil that was disturbed as a result of work performed
.under this permit with an approved dust control treatment. Soil stabilization shall be done immediately
after completing the operation.
19. Pursuant to Chapter,12.56 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982) the City
has designated certain city streets as Truck Routes. The weight limit for restricted streets (i.e., streets
not part of the Truck Route network) is three (3) tons; trucks exceeding the weight limit may use a
restricted street if making a delivery or pickup,on the subject street, or if this permit specifically grants
-permission to use the street to deliver street construction -materials and/or equipment.
20. The City of La Quinta reserves the right to revoke, suspend or void this permit at any time.
21. The permittee shall indemnify, hold harmless and assume the defense of the City from all damages, .
delay costs, costs. or expenses in law or equity that may arise out of work under this permit.
22. If it is the intent of the permittee to cut the, pavement and have it restored by a third party, the
permittee shall postpone cutting the pavement until the intended third party has acquired a permit from
the City to perform the required restoration work.
Special Conditions, Page 5 of 5
City of La Quinta
The following General and Special Provisions are attached to and made a part of
Permit Number 4393
The following shall always apply:,
ENCROACHMENT ON PRIVATE PROPERTY: This permit authorizes work to be accomplished within the City of La Quinta's right of way
ONLY. Whenever construction extends within private property, it is the responsibility of the permittee for his contractors to secure permission
from abutting property owners. Such authorization must be secured by the permittee prior to starting work.
TRACK -LAYING CONSTRUCTION EQUIPMENT: Cleated track -laying construction equipment shall not be permitted to operate on any paved
surface unless fitted with smoother -faced street pads. All mechanical outriggers shall be fitted with rubber street shoes to protect the paving
during excavations. Rubber -tired equipment only shall be used in backfill operation in paved areas. If the existing pavement is scarred, spalled,
or broken during the term of this contract or if the pavement is marred, City of La Quinta shall request that these portions of road be resurfaced
over their entire width. Resurfacing shall consist of one coat of two inches (7) of A.C. surfacing plus appropriate seal coat as specified above.
PROTECTION OF TRAFFIC: All excavations and work areas shall be properly lighted and barricaded as deemed necessary by the City
Engineer or City of La Quinta Public Works Inspectors. Suitable detours and detour signs shall be placed and maintained for the duration of the
project. The City shall be notified twenty-four hours (24) in advance of any traffic detours or delineation.
CARE OF DRAINAGE STRUCTURES: Any drainage structure to include corrugated metal pipe, concrete pipe, steel culvert and concrete
structures encountered during excavation which necessitate removal shall be replaced in kind. In the event it becomes necessary to remove or
cut existing drainage structures, City of La Quinta shall be notified prior to commencement of this work. Drainage structures and open drains
shall be kept free of debris at all times for proper drainage.
RIGHT-OF-WAY CLEANUP: Any surplus material resulting from excavation and backfill operations shall be removed from the right of way. All
paved surfaces shall be broomed clean of earth and other objectionable materials immediately after backfill and compaction. Existing gutter line
and drainage ditches shall be replaced to their original standard or better. All excess material shall be removed prior to. paving. Water tanker
shall be used, as required, to sprinkle the job site to keep down dust conditions and shall be used immediately after backfill.
DE -WATER OPERTATIONS: If de -watering operations are required and pumps are forcing water on City of La Quinta roads, it shall be the
responsibility of the permittee (contractor) to control this water and to provide off-street barricades when necessary.
CLOSING STREETS: No street shall be closed. A minimum of one lane of traffic shall be maintained at all times to provide limited access for
the adjoining property owners and emergency vehicles. In the event it is felt by the permittee that he must close a street for any length of time,
permittee shall contact this office to obtain the necessary,permission.
SPECIAL PROVISIONS
The following shall apply when indicated:
® R1 NOTIFICATION: Permittee shall be notified the City at (760) 777 - 7097 at least forty-eight hours (48) in advance of starting
construction.
® R2 UTILITY CLEARANCE: (Substructures) Prior to making any excavations within the City of La Quinta right-of-way authorized
by permit, the permittee shall contact all concerned utility companies relative to the location of existing substructures.
Damage to existing substructures resulting from operations conducted under this permit shall be the sole responsibility of the
permittee.
® R3 UTILITY CLEARANCE (Surface Structures) No work shall be done under this permit until all utilities are clear of the
proposed work site. The permittee shall notify all concerned utility companies of the proposed work. .
❑ R4 PAVEMENT WIDENING: Area between the proposed concrete gutter line and the existing road pavement shall be surfaced
with (** N/A ") inches of A.C. paving placed on ( " N/A *") inches of ( ** N/A ") aggregate sub -base course having an
"R" value of not less than ( *' N/A **) and in conformance with the City of La Quinta Road Improvement Standards and
Specifications, Ordinance #461.
® R5 PARKWAY GRADING: Area between the property line and top of the proposed concrete curb shall be graded to a slope of
one-fourth inch ('/4") to one foot (1').
❑ R6 GRADE CHECKING: City of La Quinta shall check grades upon receipt of plan and profile and/or grades as established by
a licensed engineer.
❑ R7 CURB REMOVAL FOR.DRIVEWAYS: A portion of the existing concrete curb and/or curb and gutter (" N/A *') feet shall
be removed. Curb and/or curb and gutter shall be saw cut prior to removal. Depressed curb, matching concrete gutter and
concrete driveway approach shall be constructed in conformance with City of La Quinta Standard #207.
❑ R8 DRIVEWAYS: A.C. driveways shall be constructed as not to alter existing drainage pattern. Surfacing between the property
line and the existing road paving shall be two and a half inches (2 Y2") of A.C. paving on ('* N/A *') of class (" N/A ** )
aggregate base.
® R9 SIGHT CLEARANCE: Sight Clearance of six -hundred feet (600') in all directions shall be assured and maintained at all
times.
❑ R10 SOIL STERILIZER: The area to be surfaced shall be treated with soil strerilizer. Rate of application shall comply with the
manufacturer's specifications.
City of La Quinta
® R11 COORDINATE WORK: The proposed work shall be subordinated to any operation, which the State of California or City of
La Quinta may conduct in this area during the period of this permit. Work shall be coordinated with the State or City of La
Quinta forces to preclude delay or interference with State or City of La Quinta projects.
® R12 SURVEY MONUMENTS: Prior to excavation or beginning of construction, all survey monuments which exist on the
centerline of all streets or property lines when included shall be completely tied out so they may be readily and correctly,
replaced by a licensed civil engineer or surveyor at the expense of the permittee. A complete set of notes showing the ties
to these monuments shall be furnished to the City Engineer prior to the removal of any monuments. This office shall be
notified upon completion or replacement of all survey monuments for proper clearance.
® R13 PAVEMENT CUTTING: Pavement will be mechanically saw cut to a straight edge prior to excavation. Method of pavement
cutting shall be approved through the office of the City Engineer. (Under no circumstances shall excavating equipment be
used to excavate prior to cutting or pavement.) Excavation material shall be placed in such a position as to best facilitate the
general flow traffic. Prior to final paving operations, any damage to pavement straight edges shall be corrected.
❑ R14 LIMIT OF EXCAVATIONS: Excavations shall be limited to one -thousand feet (1000') of open trench before backfill
operations must begin. All excavations shall be properly barricaded with lights overnight, on weekends and holidays for the
protection of the traveling public. The Public Works Inspector shall determine the suitability of excavation barricading in
each case. No excavation shall remain open for a period exceeding five (5) days. No excavation shall be made unless the
construction material is actually on the work site.
® R15 BACKFILL MATERIAL: Backfill shall be free of brush, roots or other, organic substance detrimental to its use for purposes
of producing and adequately consolidated backfill. Ant material which the City of La Quinta deems unsuitable (spongy or
saturated material) which is encountered during excavation shall not be used for backfill, but shall be supplemented or
replaced by an approved sand or gravel.
❑ R16 BACKFILL SAND: Backfill shall be approved transit -mix sand or equivalent and shall be placed on lifts not greater than
three feet (3') and vibrated using vibrostamper or equivalent equipment. Alternate methods may be substituted, but in any
case, a relative compaction of ninety-five percent (95%) shall be maintained with the structural section of the roadway.
❑ R17 BACKFILL PLACEMENT: Backfill shall be applied in layers of not more than fifty percent (50%) of the total depth of the
trench before flooding or a maximum of five feet (5) lifts where trenches are of excessive depths. Care is to be exercised
'that the backfill material is not subjected to extreme swell by flooding operations. Backfill material shall be placed so that the
resulting compaction shall not be less than ninety percent (90%) or equivalent to the surrounding ground, whichever is the
greater compaction. Where ponding or flooding is used for a maximum, settlement, adequate dikes will be constructed to
retain the water.. Where jetting is used, the'jets shall be of sufficient length to reach the bottom of each layer and the water
supply shall be continuos.
® R18 COMPACTION TESTS: If so required by the inspector, compaction test shall be made at intervals of not more than one -
thousand (1000') feet and a maximum of one (1) test on each road. One (1) copy of each test shall be forwarded tot the City
Engineer for approval and filed prior to making permanent repairs. Compaction tests shall be made as outlined in Section
6.3.01 of the Standard Specifications, Division of Highways, State of California, dated January 1973.
❑ R19 COMPACTION TESTS: If so required by the Inspector, compaction tests shall be made for each crossing or service line.
One (1) copy of each test shall be forwarded to the City Engineer for approval and filed prior to making permanent repairs.
Compaction tests shall be. made as outlined in Sections 6.3.001 of the Standard Specifications, Division of Highways, State
of California, dated January 1973.
® R20 TEMPORARY PAVEMENT REPAIRS: After completion of backfill and compaction operations, a temporary patch consisting
of two inches (2") of SC-800 shall be placed on a prepared sub -grade. The SC-800 temporary paving shall be placed after
a maximum of three -thousand linear feet (3000') or trench has been excavated and backfill operations completed, but in no
case shall the placement of the temporary pavement exceed a five (5) day limit.
® R21 PERMANENT PAVEMENT REPAIR: After backfill and compaction have been completed, a temporary patch consisting of
two inches (2") of SC-800 shall be placed immediately. A permanent patch of ( 3 ) inches of A.0 surfacing placed on a• ( 6 )
inch ( crushed ) aggregate base shall be placed no later than ( 5 ) days after completion of temporary road repair.
❑ R22 FOG SEAL: A fog seal coat. consisting of an application of asphaltic emulsion shall be applied over all patch areas as
determined by the City Engineer.
® R23 STREET RESTRIPING: Where street striping is still visible on street to be excavated, such striping shall be replaced upon
completion of permanent repairs.
® R24 TREE RELOCATION OR REMOVAL: Tree relocation within the City of La Quinta road right-of-way shall be accomplished
by a licensed, bonded and insured tree service, and handled safely without interference or hazard to the traveling public. It
shall be the responsibility of the permitte to maintain the tree in a vigorous growing condition at its new location.
Trees to be removed shall be in sections, which can be handled safely without interference or hazard to highway traffic. The
entire width of the tree stump, shall be removed and disposed of so that no debris remains in view of the highway. The
stump hole shall be backfilled and thoroughly compacted as specified in the following paragraph. .Where it becomes
necessary to restrict traffic, -the work shall be restricted to a maximum of five -hundred feet (500') at any one time. Adequate
signs, flagmen and or barricades shall be provided to protect the traveling public at all times.
Large holes resulting from tree removal shall be backfilled and compacted to not less than ninety percent (90%) or
equivalent tot the surrounding ground, whichever is the greater compaction as determined by the impact or field method.
Compaction tests shall comply with Section 6.3.01 of the Standard Specifications, Division of Highways, State of California,
dated January 1973.