Loading...
05-5177 (SFD)��+'ter ', .� ���INI{I� • P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT = BUILDING PERMIT' Application Number: 05-00005177 Property Address: 79315 TOM FAZIO LN N APN: 766 -032 -008 - Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: .504387 Applicant: Architect or Engineer: 1 Owner: M/M SIMMONS 79315 COUNTRY CLUB DR LONG BEACH, CA 9080j,7_, Contractor: CLARK JR, JACK L. ,..51220 AVENIDA CAR LA QUINTA, CA 922 3 '(760).564-3511 - Lic. No.: 506667 VOICE (760) 777-7012 FAX (760) 777-7011 ` INSPECTIONS (760) 777-7153 Date: 3/14/06 ?MAR 2 01006 ------------------------------------------------ ----------------------------------------- - - - - -- — ' LICENSED CONTRACTOR'S DECLARATION_ WORKER'S COMPENSATION DECLARATION , I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided .License C ass: B •-� . License No.: 506667 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is _ +'n f 1 _ /date: q'' �•'✓/�ontrector, r I��� t- �e ��� issued. _ I have and will maintain workers' compensation insurance, as required by Section 3760 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Cairier EXEMPT Policy Number EXEMPT following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any str6cture, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 byany 3700 of the Labor Co I shall forthwith omply with those provisions.)that -VTAN applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (S500).: = G� Appl- I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNLURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner'of property who builds or improves thereon, SUBJMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND - _- and who does the work himself or herself through his or her own employees, provided that the - DOLLARS 15100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND, ATTORNEY'S FEES._ one year of completion, the owner -builder will have the burden of proving that he or she did not build or , improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT ... - (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1 . Each person upon whose behalf this application is made, each person at whose request and for ' pursuant to the Contractors' State License Law.). _ whose benefit work is performed under or pursuant to any permit issued as a result of this application, I am exempt under Sec. , B.&P.C. for this reason - the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La 6uinta; its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced • - within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject - - CONSTRUCTION LENDING AGENCY _ permit to cancellation. - - - - I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this' application and state that the above information is correct. I agree to comply with all work for which this permit is issued (Sec: 3097, Civ. C.). city and county ordinances and state laws relating to building construction, and hereby authorize representatives Lender's Name: • of this co my - enter upon the above-mentioned prop for inspection pur, o as. ' �-+'" Z, n / a. Fb� e %5 pplicant or Agent): �; 4-c `� r�C`��� Lender's Address: - LQPERNIIT, I r Application Number . . . . . 05-00005177 Permit BUILDING PERMIT Additional desc Permit Fee 2054.50 Plan Check Fee 1335.43 Issue Date . . . . Valuation 504387 Expiration Date •9/10/06 Qty Unit Charge Per Extension BASE FEE 2039.50 5.00 3.0000 ---------------------------------------------------------------------------- THOU BLDG 5001001-1,000,000 15.00 Permit . . . MECHANICAL Additional desc . Permit.Fee . . . . 176.00 Plan Check Fee 44.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 9/10/06 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 9.0000 EA MECH FURNACE <=100K 27.00 2.00 11.0000 EA MECH FURNACE >100K 22.00 3.00 9.0000 EA MECH B/C <=3HP/100K BTU 27.00 2.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU. 33.00 7.00 6.5000 EA MECH VENT FAN 45.50 1.00 6.5000 -------------------------------'--------------------------------------------- EA MECH EXHAUST HOOD 6.50 J Permit . . . ELEC-NEW RESIDENTIAL. Additional desc . Permit Fee . . . . 255.73 Plan Check Fee 63.93 Issue Date Valuation . . . . 0 Expiration Date .9/10/06 Qty Unit Charge Per Extension BASE FEE 15.00 5859.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 205.07 1033.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 20.66 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit PLUMBING Additional desc . Permit Fee 255.00 Plan Check Fee 63.75 Issue Date . . . . Valuation . . . . 0 Expiration Date 9/10/06 Qty -Unit Charge Per Extension r LQPERN•fIT 41 r Application Number . . . . . 05-00005177 Permit . . . . . . PLUMBING Qty Unit Charge Per Extension BASE FEE 15.00 24.00 6.0000 EA PLB FIXTURE 144.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 5.00 6.0000 EA PLB ROOF DRAIN 30.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 12:00 .7500 EA PLB GAS PIPE >=5 9.00 1.00 15.0000 ---------------------------------------------------------------------------- EA PLB GAS METER 15.00 Permit GRADING PERMIT Additional desc . Permit Fee 15.00 Plan Check Fee .00 Issue Date . . . Valuation . . . . 0 Expiration Date 9/10/06 Qty Unit Charge Per Extension BASE FEE 15.00 ----------------------------------- ---------------------------------------- Special Notes and Comments 5859 SQ.FT. SFD. PERMIT DOES NOT INCLUDE BLOCK WALLS,'POOL/SPA ---------------------------------------------------------------------------- Other Fees. . . . . . . . ART IN PUBLIC PLACES -RES 760.96 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER.- RES 480.00 ENERGY REVIEW•FEE 133.54 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE 15.00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 8.92.00 STRONG MOTION (SMI) - RES 50.43 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1666.00 Fee summary Charged Paid. Credited --------------------------------------------------------- Due Permit Fee Total 2756.23 .00 .00 2756.23 Plan Check Total 1507.11 750.00 .00 757.11 Other Fee Total 4655.93 .00. .00 4655.93 Grand Total 8919.27 750.00 .00 8169.27 LQPE%NIIT Od Certificate of Occupancy Lcoerowhn �4 oF�9ti Building &Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure .was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 79-315 TOM FAZIO LANE N. Use classification: SFD Building Permit No.: 05-5177 Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL Owner of Building: M/M SIMMONS Address: 79-315 TOM FAZIO LANE N. City, ST, ZIP:LA QUINTA, CA 92253 By: DAVID GATICA Date: MAY 01, 2007 Building Official � POST IN A CONSPICUOUS PLACE Od Certificate of Occupancy �J Building -7q.>1c� -rM F 4 P.O. BOX 1504 �� �� ' 1� 78-495 CALLE TAMPICO APL Q0 ONLY ID u1NF_NoffN LA OUINTA, CALIFORNIA 92253 • owner 13/`D �•/)ZtibAraq SIMMWS Mailing (lZ40pr w"6 CL("6 h `, Address -T C� Uvc, Contractor Address ¢ Z 2zs3 Tel --35�� State Lic.City & Classif. SO 6&40 40 ^J Lic. # tngr., Designer 'I�QtVID 'rsT Designer Address Tel. yy- D SANPs LD Ave *UDI 7b0 --171-53g. CityZ Zip 9 ZZ(o D StateLic. # Gl,.- / D t0 V LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, Improve, demolish, or repair any structure, prior to its Issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). i'' I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Bussness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building orimprovement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I I I, as owner of the properly, am exclusively contracting with licensed contractors to con. struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) f! I am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION Ihereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company f7 Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thF work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, atter making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip UILDING: TYPE'CONST. V- N OCC. GRP. h-✓ .P. Number D Gb/" 032.— 009 e Z egal Description 7y-A� MAP Ori. 2-T720 - LOT 53 roject Description S/ AJGLE' 'F-,,tA4<C of f769M Sq. Ft. Size New'b No. No. Dw. Stories I Units Add ❑ Alter ❑ Repair ❑ Demolition ❑ >timated Valuation PERMIT AMOUNT-, Plan Chk. Dep. S� Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE: BY:- Minimum Y:_Minimum Setback Distances: Front Setback -fro ri6LCente�e: Rear St i�bt�ck fromll=-�Ree�ar Prop. Li Side St�`eet;'Setback from Center Side Set b ck from,Properrtty Line FINAL DATE IN$PECT ),A_ Issued by: )Date GIVII -Permit Validated by: Validation: WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE Date 3/13/06 No. 28231 Owner M/M Bill Simmons Address City Zip Tract # Type Single Family Residence CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # Jurisdiction Permit # Study Area No. of Units IFZS Q BERMUDA DUNES O RANCHO MIRAGE t_J -) INDIAN WELLS PALM DESERTLA y moo.NDIO TA II1�. . y� 0 766-032-008 La Quinta 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 79315 Tom Fazio Lane North 5859 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.63 X 5,859 S.F. or $15,409.17 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/La Jolla Bank - Shaun Clark Name on the check By Dr. Doris Wilson Superintendent Check No. 03000362 Telephone 405.208.2213 Funding Residential Fee collected /exempted by Sharon MCGllvrey Payment Recd $15,409.17 over/Qhcf, Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting I TABLE OF CONTENTS - I Cover Page Table of Contents Form CF -IR Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads Glazing Performance Ratings / Specifications HVAC Performance Ratings / Specifications HVAC ARI Ratings Lighting Specifications 4. 1 2 3 8 10 11 14 17 20 25 31 47 49 EnergyPro 4.0 , by EnergySoft Job Number: 24100 User Number: 3665 Certificate Of Compliance: Residential (Part 1 of 3) CF -1 R _B.1LaadRhonda S_immon.s 5,859 ft2 Existing Floor Area: 2L22/20Q6 Project Title _L-The_Q.uarty-La- Uinta Raised Floor Area: 0 Date Project Address 5,859 ft2 Building Permit # BREEZE AIR C01VD=_ _ ft (760) 346-0855 1.00 Plan Check/Date Documentation Author New Telephone Z0 -NF #9 -Energy Pip 28- 15 Nenr Field Check/Date Compli ce Method New Climate Zone ZONE #2 Source Energy Use Standard Proposed Compliance New (kBtu/sf-yr) Design Design Margin 0.9_A6 Space Heating 1.89 2.40 -0.51 ZONE#=t Space Cooling 58.29 52.01 6.27 New- Fans 8.77 9.84 -1.07 Domestic Hot Water 4.38 5.87 -1.49 Pumps 0.00 0.00 0.00 Totals 73.32 70.12 3.20 n Standard: Building Type: [X-] Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition El Existing + Add/Alt (North)15 deg Natural Gas Area: 2,050 ft 2 Avg. U: 0.46 Ratio: 35.0% Avg. SHGC: 0.33 BUILDING ZONE INFORMATION Zone Name Floor Area Volume 4.4 Total Conditioned Floor Area: 5,859 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 5,859 ft2 Average Ceiling Height: 11.9 ft Number of Dwelling Units: 1.00 _01_A18 Number of Stories: # of Thermostat Units Zone Type Type .HVAC -#J119 14,304 _0.20_ Conditioned- -Setback- HVAC #2 3.,3.92 X2,4.0.0 _0.5B_ conditioned_ -Setback- _H _V_AC 3 1275 x.2,150 -Q.22_ Conditioned_ Setback__ OPAQUE SURFACES Insulation Act. Type Frame Area LI -Fac. Cay. Cont. Azm. Tilt .Roof Wood- 1 192 0.025_ R_ 8_ X0_0 0_ 0. Wall- Wood- X9.0_ 0..0_69_-ft210`0_0_ ____t5_-90 Wall_ Wood_ 88_ 0.089 -}32100_0 105__9.0 Wall Wood- -243_ -0.0.69_ 8-910-0.0_X9.5_ 9.0 Wall_ Wood_ _3.8.5.0..069 021 X0...0_ -285.90 Roof Wood_ -3,3.92 0..025_ __R_ -3B_ X0.0 _0_ 0 Wall- Wood- 428.0.0.69.0210`0_0_ x.5.90 _Door None- 63.0_5.00_ done_ _R=0_0_ ---15---90 Wall- Wood_ 3.50.0 OB9 IR -91 _JR -_0 Q _1.05_ 9.0 Wall- Wood- -282 -O-Q6.9- 021 X0..9 ___i9.5_____9.0. Wall_ Wood- 142 _0_0.69 021 _R -_0A__285_ go Roof_ Wood- 275.0025_ R_3.8.0``0_0 0_ n Wall_ blond- 3.8.9_ _0_0.69 021 X0..0_ 1590 Wall_ Wood_ _280_ 0._06a -R-91 13 00 -109-9.0_ Wall_ Wood- -39.3_ _U69- 0210`0_.0_ _195_ 9.0 Wall_ Wood_ 3.5.6_ 0.0690210:_0_0__-28.5__9.0. Vent Hgt. Area -2 n/n -n/a n/a Gains Condition Y / N Status JA IV Reference Location / Comments New _0.11.8 ZONE #1 New 0.916 ZONE #1 N.ew 0.916 ZONE #1 New _0.96 7-ONE#1 New _0.9 6 ZONE#1 New _01_A18 7_0.NE#2 New _0.9_A6 Z0 -NF #9 New 28- Z0.NE#2 Nenr 00A6 ZONE#2 New _0.9A6 ZONE #2 New _0.9 A6 ZONE Jr2 _ New Od A1.8 ZONE #3 N.ew 0.9_A6 ZONE - #3 -New Q9 A6 ZONE#=t N.ew _0.9_A6 ZONE-#3- ONE#3New New- 0.9-A6 ZONE1=1 I EnergvPro 4.0 by EnergvSoft User Number: 3665 Job Number: 24100 Page:3 of 51 1 Certificate Of Compliance: Residential (Part 2 of 3) CF -1 R Bill and Rhonda Simmons Location/ Comments 108 None No Insulation 2/22/2006 Project Title ZONE #1 27 None No Insulation Date FENESTRATION SURFACES ZONE #1 213 53 None No Insulation None No Insulation 26-A1 26-A1 New New ZONE #2 ZONE #2 True Cond. Location/ # Type Area LI -Factor" SHGC2 Azm. Tilt Stat. Glazing Type Comments J- -Window-Left(East) 7 0- GA8.0NERC _0.32 NFRC 1.0.5_ _9.0 New-Beetwood-#303.3-(.Sliding-Door)ZO.NE#1 2 Window Rear (South) 59.0 0.400 NFRC 0_34 NFRC 195 90 New Fleetwood #530T (Fixed) ZONE #1 3 Window Rear South) 144.0 0.550 NFRC 0_32 NFRC 195 90 New Fleetwood #3070 (Sliding Door)ZONE #1 4 Window Rear (South) 4.0 0.400 NFRC 0_34 NFRC 195 90 New Fleetwood #530T (Fixed) ZONE #1 5 Window Rear South) 72.0 0.400 NFRC 0_34 NFRC 195 90 New Fleetwood #530T (Fixed) ZONE #1 6 Window Right (West) 81.0 0.400 NFRC 0_34 NFRC 285 90 New Fleetwood #530T (Fixed) ZONE #1 7 Window Right Msdt) 4.0 9 40 NFRC-Q34 JCC 285 9.2 New Fleetwood #530T (Fixed)_ ZONE #1 8 Window Front (North) 63.0 0.480 NFRC 0.32 NFRC 15 90 New Fleetwood #3033 (Sliding Door)ZONE #2 9 Window Front (Nort ) 112.0 0.40 NFRC 0.34 NERC 15 90 New Fleetwood #530T (Fixed) ZONE #2 J0 Window Front (North) 27.0 0.40 NFRC 0.34 NERC 15 �9 New Fleetwood #530T (Fixed) ZONE #2 11 Window Front (North) 4.0 0.400 NFRC 0_34 NFRC 15 90 New Fleetwood #530T (Fixed)_ ZONE #2 12 Window Left (East) 52.0 0.400 NFRC 0_34 NFRC 105 90 New Fleetwood #530T (Fixed) ZONE #2 13 Window_L.eft_(Eas1) 144.0 _0 400_N RQ 0-M -NERC X00 90 New Eleetwood-#530I..(Eimd.)_ ZONE #2 14 Window Left (East) 90.0 0.400 NFRC 0_34 NFRC 105 90 New Fleetwood #530T (Fixed) ZONE #2 15 Window Rear South) 150.0 0.550 NFRC 0_32 NFRC 195 90 New Fleetwood #3070 (Sliding Door)ZONE #2 16 Window Rear (South) 260.0 0.550 NFRC 0_32 NFRC 195 90 New Fleetwood #3070 (Sliding Door)ZONE #2 17 Window Rear (South) 85.0 0.480 NFRC 0_32 NFRC 195 90 New Fleetwood #3033 (Sliding Door)ZONE #2 18 Window Rear (South1) 18.0 0.400 NFRC 0_34 NFRC 195 90 New Fleetwood #530T (Fixed) ZONE #2 19 Win ow Right (Wes ) 52.0 0.400 NFRC 0.34 NFRC -2 5 90 New ELeetwo9_d #U"Fix ZONE #2 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang_ Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 9.0 8.0 3.0 0.1 3.0 3.0 2 Bug Screen 0.76 4.5 16.0 5.0 0.1 5.0 5.0 3 Bug Screen 0.76 9.0 16.0 5.0 3.0 5.0 5.0 4 Bug Screen 0.76 5 Bug Screen 0.76 9.0 8.0 3.0 0.1 3.0 3.0 6 Bug Screen 0.76 8.5 --9-5 --3-0 -0-1 -3-0 iQ 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 9.0 6.0 3.0 0.1 3.0 3.0 13 Bug Screen 0.76 13.5 12.0 3.0 0.1 3.0 3.0 14 Bug Screen 0.76 15 Bug Screen 0.76 10.0 15.0 5.0 0.1 5.0 5.0 16 Bug Screen 0.76 10.0 26.0 13.0 3.0 13.0 13.0 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 8.0 6.0 4.0 0.1 4.0 4.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Slab Perimeter Slab Perimeter Slab Perimeter Slab Perimeter Length Insulation R -Val. Location JA IV Reference Condition Status Location/ Comments 108 None No Insulation 26-A1 New ZONE #1 27 None No Insulation 26-A1 New ZONE #1 213 53 None No Insulation None No Insulation 26-A1 26-A1 New New ZONE #2 ZONE #2 Slab Perimeter 139 None No Insulation 26-A1 New ZONE #3 Run Initiation Time: 01/10/06 16:42:37 Run Code: 1136932957 EnergyPro 4.0 by EnergySoft User Number. 3665 Job Number: 24100 Page:4 of 51 Certificate Of Compliance: Residential (Part 2 of 3) CF -1 R Bill and Rhonda Simmons 2/22/2006 Project Title Date FENESTRATION SURFACES # Type Area True Cond. U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Location/ Comments .20. Window-RigbL---(-West) 7 JL -0..40.0-NFRC-0_34 NFRC _28.5_ _9.0_N.ew-Fleetwood-#5-0T (Fixed)_ JAN # 21 Window Right (West) 24.0 0.400 NFRC 0_34 NFRC 285 90 New Fleetwood #530T (Fixed) ZONE #2 22 23 Window Window Front Front (North) 4.0 (North) 4.0 0.400 NFRC 0_34 NFRC 15 0.400 NFRC 0_34 NFRC 15 90 New Fleetwood #530T (Fixed) 90 New Fleetwood #530T (Fixed) ZONE #3 ZONE #3 24 Window Front (North) 4.0 0.400 NFRC 0_34 NFRC 15 90 New Fleetwood #530T (Fixed) ZONE #3 25 Window Front (North) 4.0 0.400 NFRC 0_34 NFRC 15 90 New Fleetwood #530T (Fixed) ZONE #3 26 Window Front (North) 4.0 0.400 NERC 034 NFRC 15 90 New Fleetwood #530T (Fixed) ZONE #3 27 Window Front North) 4.0 0.400 NFRC 0.34 NFRC 15 90 New Fleetwood #530T (Fixed) ZONE #3 28 Window Front (NQrth) 72.0 0,48 NFRC 0.32 _NFRC_ 15 -RQ- New E1eetwood #3033(Si Door)ZQ E #3 2,9 Window Left (East) 72.0 0.489 NERC 02 NFRC 105 90 New Fleetwood #3033 (Sliding Doo )ZONE #3 3Q 31 Window Window Left Left (East) 4.5 (East) 36.0 0.400 NFRC 0_34 NFRC 105 0.400 NFRC 0_34 NFRC 105 90 New Fleetwood #530T (Fixed) 90 New Fleetwood #530TFixed ZONE #3 ZONE #3 32. 33 34 -Window-Leff--i(East) 720 Window Rear South) 27.0 Window Ri hg t (West) 54.0 -0.48.0-NFRC 0.32 SIFRC --JD5_ 0.400 NFRC 0_34 NFRC 195 0.400 NFRC 0_34 NFRC 285 90 Neve Fleetwood 0033-piding-DoorlZONE #3 90 New Fleetwood #530T (Fixed) ZONE #3 90 New Fleetwood #530T (Fixed) ZONE #3 27 Bug Screen 0.76 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang_ Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 10.0 7.0 4.0 0.1 4.0 4.0 0.1 4.0 0 0.1 4.0 0 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 9.0 8.0 4.0 0.1 4.0 4.0 30 Bug Screen 0.76 31 Bug Screen 0.76 9.0 4.0 3.0 0.1 3.0 3.0 0.1 4.0 0 0.1 4.0 0 32 Bug Screen 0.76 9.0 8.0 4.0 0.1 4.0 4.0 33 Bug Screen 0.76 34 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Insulation PERIMETER LOSSES Location/ Condition Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 35 None No Insulation 26-A1 New ZONE #3 Run Initiation Time: 01/10/06 16:42:37 Run Code: 1136932957 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. 24100 Page:5 of 51 Certificate Of Compliance: Residential (Part 3 of 3) CF -1 R Bill and Rhonda Simmons 2/22/2006 Project Title Date HVAC SYSTEMS HVAC DISTRIBUTION Location Heating Cooling HVAC #1 Ducted Ducted HVAC #2 Ducted Ducted HVAC #3 Ducted Ducted Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC #1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC #2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC #3 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Location Heating Cooling HVAC #1 Ducted Ducted HVAC #2 Ducted Ducted HVAC #3 Ducted Ducted Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Duct Condition Ducts Location R -Value Status Tested? Attic 6.0 New Yes Attic 6.0 New Yes Attic 6.0 New Yes WATER HEATING SYSTEMS Rated Tank Energy Standbyl Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. Standard Gas 50 gal or Less Small Gas No Pipe Insulation 2 40,000 50 New 0.57 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length ft Add 1/2" Control # HP Tvpe In Plenum Outside Buried Insulation 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Prest/Vuksic Architects Address: 44-530 San Pablo Ave, #200 Palm Desert, CA 92260 Agency Title/Firm: Address: Telephone: Documentation Author Name: Brad Stone Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 2 (signature/stamp) (date) I EnerpvPro 4.0 by EnergvSoft User Number: 3665 Job Number: 24100 Paae:6 of 51 1 Certificate Of Compliance : Residential (Addendum) CF -1 R Bill and Rhonda Simmons 2/22/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist: These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agencv determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the rdequacy of the special justification and documentation submitted. IThe Roof "R-38 Roof' includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. Plan I Field HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -411 Plan I Field installation certificate. The HVAC System "HVAC #1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -41 1. The HVAC System "HVAC #1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "MAYTAG PSA1 BD / PGC1 RA (5 Ton)" includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "HVAC #2" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC #2" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "MAYTAG PSA1 BD / PGC1 RA (4 Ton)" includes credit for a 12.4 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "HVAC #3" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -41R. The HVAC System "HVAC #3" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "MAYTAG PSA1 BD / PGC1 RA (5 Ton)" includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. I EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: 24100 Page:7 of 51 1 Mandatory Measures Summary: Residential (Page 1 of 2)' MF -1 R NOTE: Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercedes the items marked with and asterisk (*) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not applicable. NIA DESIGNER ENFORCE - MENT Building Envelope Measures ❑ 0� ❑ �§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑ ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑X ❑ ❑ *§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑X ❑ *§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. z ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ 0� ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑x ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ FRI ❑ b. outside air intake with damper and control, flue damper and control ❑ N ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑x ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑X ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑X ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ ❑x ❑ § 118: , Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑K ❑ ❑ CF -6R Form: ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ER ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain El N El (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ 0� ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑x ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. . 2. Back-up tanks for solar systems, unfired storage tanks; or other indirect hot water tanks have R-12 external ❑ IR ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First'5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑x ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heatingsystems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑X ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ Q ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑X ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. N ❑ ❑ EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: 24100 Page:8 of 51 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - DESCRIPTION NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ X❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and electric and have an output frequency no less than 20 kHz. support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause ❑ Q ❑ luminaire has factory installed HID ballast. reductions in the cross-sectional area of the ducts. ® ❑ ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. X❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ® ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑X ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. electric and have an output frequency no less than 20 kHz. 2. System is installed with: ❑ Q ❑ luminaire has factory installed HID ballast. a. At least 36" of pipe between filter and heater for future solar heating. ® ❑ ❑ b. Cover for outdoor pools & outdoor spas. X❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. X❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ © ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteriaX❑ ❑ ❑ Lighting Measures ❑ § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ Q ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, ❑ provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. . § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) ceritfied to comply with Section 119(d). X❑ § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms be high luminaires less than 70 ft) OR by dimmer OR ❑ ❑X ❑ shall efficacy (except closets are controlled a switch are controlled by an occupant sensor that complies with Section 199(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. FAI ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more X❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: 24100 Page:9 of 51 Residential Kitchen Lighting Worksheet WS -5R Bill and Rhonda Simmons 2/22/2006 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. Luminaire Type High Efficacy? Watts Quantity High Efficacy Watts Other Watts U 14w Linear T5 Elec Yes X No 18.0 x 1 = 18 or U 21w Linear Flour. T5 Elec Yes X1 No 1 27.0 x 4 = 108 or (1) 28w Linear Flour. T5 Elec Yes X1' No 30.0 x 5 = 150 or 4'T12 Flour. Yes No X 40.0 x 1 = or 40 50w Low Voltage Halogen Yes No X 55.0 x 4 = or 220 Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: " 276 B: 260 COMPLIES IF A >_ B YES ® NO ❑ I EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. 24100 Page: 10 of 51 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Bill and Rhonda Simmons 2/22/2006 SYSTEM NAME FLOOR AREA HVAC #1 1,192 Number of Systems 1 Heating System Output per System 86,000 Total Output (Btuh) 86,000 Output (Btuh/sgft) 72.1 Cooling System Output per System 57,000 Total Output (Btuh) 57,000 Total Output (Tons) 4.8 Total Output (Btuh/sqft) 47.8 Total Output (sgft/Ton) 250.9 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sqft) 1.68 Airflow (cfm/Ton) 421.1 Outside Air (%) 4.5 Outside Air (cfmisqft) 0.08 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 27,0641 3,4971 MAYTAG PSA1BD / PGCIRA (5 Ton) 50,401 0 86,000 Total Adjusted System Output 50,401 0 86,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK F777Z9 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 67.3 of 107.70 107.7 of O Supply Air Ducts Outside Air 89 cfm Heating Coil Supply Fan 106.9 of 2000 cfm ROOMS 70.0 of 69.2 of 1% Return Air Ducts `S 1000LING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) I 111.0/77.6OF 80.3/64.4OF 56.6/55.3OF 56.6/55.3OF O Supply Air Ducts Outside Air 89 cfm Cooling Coil Supply Fan 57.5 / 55.7 of 2000 cfm 44.7% R.H. ROOMS 78.9/63.6 of 78.0 / 63.3 of 1% Return Air Ducts `i EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. 24100 Page: 11 of 51 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Bill and Rhonda Simmons 2/22/2006 SYSTEM NAME FLOOR AREA HVAC #2 3,392 SYSTEM LOAD I Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 2,43 54,763 3,937 1,701 54,442 0 4,972 4,336 0 0 254 8,665 4,928 254 11,683 0 0 4,972 4,336 73,373 8,865 1 74,797 MAYTAG PSAIBD / PGC1RA (4 Ton) 126,751 0 174,000 Total Adjusted System Output 126,751 0 174,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pmt I Jan 12 am (HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) I 26.0 of 66.9 of 100.9 of 100.9 of O Supply Air Ducts Outside Air 254 cfm 100.1 of Heating Coil Supply Fan 4800 cfm ROOMS 70.0 of 69.2 of 11.0/77.60F Outside �� 254 cfm 79.0/63.2 of 80.7 / 64.1OF �% Return Air Ducts `i 55.9/54.5OF Cooling Coil Supply Fa 4800 cfm 55.9 / 54.5 of Supply Air Ducts Fan 56.8 / 54.9 of 43.2% R.H. ROOMS 78.0 / 62.9 of h Return Air Ducts '4 EnergyPro 4.0 by EnergySoft User Number. 3665 Job Number. 24100 Paae:12 of 51 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Bill and Rhonda Simmons 2/22/2006 SYSTEM NAME FLOOR AREA HVAC #3 1,275 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 86,000 Total Output (Btuh) 86,000 Output (Btuh/sgft) 67.5 Cooling System Output per System 57,000 Total Output (Btuh) 57,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 44.7 Total Output (sgft/Ton) 268.4 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sqft) 1.57 Airflow (cfm/Ton) 421.1 Outside Air (%) 4.8 Outside Air (cfm/sqft) . 0.08 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAKCOIL HTG. PEAK CFM Sensible Latent CFM Sensible 964 20,920 1,979 585 22,818 107.5 of 0 Supply Air Ducts 1,899 1,817 0 0 96 3,265 1,690 96 4,391 0 Heating 0 1,899 1,817 27,985 3,669 30,843 MAYTAG PSA1 BD / PGC1 RA (5 Ton) 50,488 0 86,000 Total Adjusted System Output50,488 0 86,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 67.1 of 107.5 of 107.5 of Supply Air Ducts O Outside Air 96 cfm 106.6 of Heating Coil Supply Fan 2000 cfm ROOMS 70.0 of 69.1 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 of 80.4 / 64.5 of 56.7 / 55.4 of 56.7 / 55.4 of O Supply Air Ducts Outside Air 96 cfm Cooling Coil Supply Fan 57.6 / 55.8 of 2000 cfm ROOMS 44.9% R.H. OF 78.0 / 63.4 of 78.9/63.7 EnergyPro 4.0 by EnergySoft User Number. 3665 Job Number: 24100 Page: 13 of 51 ROOM LOAD SUMMARY PROJECT NAME Bill and Rhonda Simmons DATE 2/22/2006 SYSTEM NAME HVAC #1 FLOOR AREA 1,192 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #1 HVAC #1 1 931 20,319 1,902 931 20,319 1,902 553 21,690 PAGE TOTAL 1 931 20,319 1,902 553 21,690 TOTAL 1 931 20,319 1,902 553 21,690 EnergyPro By EnergySoft User Number: User Job Number: 24100 Page: 14 of 51 ROOM LOAD SUMMARY ::1 PROJECT NAME Bill and Rhonda Simmons DATE 2/22/2006 SYSTEM NAME HVAC #2 FLOOR AREA 3,392 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #2 Living Area 1, 2,431 54,763 3,937 2,431 54,763 3,937 1,701 54,442 PAGE TOTAL 1 2,431 54,763 3,937 1,701 54,442 TOTAL 1 2,431 54,763 3,937 1,701 547442 EnergyPro By EnergySoft User Number. User Job Number: 24100 Page: 15 of 51 ROOM LOAD SUMMARY PROJECT NAME Bill and Rhonda Simmons DATE 2/22/2006 SYSTEM NAME HVAC #3 FLOOR AREA 1,275 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM. SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #3 Guest Bedrooms 1 964 20,920 1,979 964 20,920 1,979 585 22,818 PAGE TOTAL 1 964 20,920 1,979 585 22,818 TOTAL 1 964 20,920 1,979 585 22,818 EnergyPro By EnergySoft User Number: User Job Number: 24100 Page:16 of 51 ROOM HEATING PEAK LOADS 7-71 Project TitleDate Bill and Rhonda Simmons 2/22/2006 Room Information Design Conditions Room Name HVAC #1 Time of Peak Jan 12 am Floor Area 1,192 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value Z�,T of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 17 579 Infiltration: [ 1.001X 1.064 x 1 192 x 12.00 x 0.368 / 6] x ® = 4 111 Schedule AIr Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 23,161 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. 24100 Page: 17 of 51 1192.0 x X x X X X x X X X x X x X x X x X X X X x X X x X X X X X x X x X X X X X X 0.0250 X X X X X x X X X x X X X x x X X x X X X X x X X X X X X X X X X X x X X X X 44 = = = = = = = = = = = = = = = = = 1,311 290.0 0.0690 44 880 88.0 0.0690 44 267 72.0 0.4800 44 1,521 243.0 0.0690 44 738 59.0 0.4000 44 1,038 144.0 0.5500 44 3,485 4.0 0.4000 44 70 72.0 4 44 1,267 385.0 0.0690 1,169 81.0 0.4000 44 14 6 4.0 0.4000 44 70 perimeter = 108.0 0.7300 44 3,469 perimeter = 27.0 0.7300 44 867 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 17 579 Infiltration: [ 1.001X 1.064 x 1 192 x 12.00 x 0.368 / 6] x ® = 4 111 Schedule AIr Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 23,161 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. 24100 Page: 17 of 51 ROOM HEATING PEAK LOADS Project Title Date - Bill and Rhonda Simmons 12/22/2006 Room Information Desi n Conditions Room Name Living Area Time of Peak Jan 12 am Floor Area 3,392 Outdoor Dry Bulb Temperature .26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value OT of Btu/hr 'Solid Wood Door 'R-21 Wall - 8Boo R-21 Wall _le.etwood_#3.0.3.3_(.Sliding_Door Solid Wood Door Fleetwood (Fixed) Fleetwood #5307 Fixed F�eetw.00d-#530T(F�xed R-21 Wall -leetwood-#530L(.Eixed) Fleetwood #5307 (Fixed) Fleetwood #5307 Fixed R-21 Wall e-etwood.#307_0_(.Sliding nnorl eetwnod_#3.070ASlidirn n Fleetwood -#.3033 -(.Sliding -Door) Fleetwood (Fixed) R-21 Wall .Fleetwood -#530I -(Fixed Fleetwood #530L(Fixe Fleetwood #530T Fixed Slab -On -Grade Slab -On -Grade i e Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 42 745 Infiltration: C TRX 1.064 X 3 392 X 12.50 x 0.354 / 60] X 44 = 11 698 Schedule Air Sensible ` Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 59,290 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: 24100 Page: 18 of 51 24.0 x x x X X X x X X X X X X x X X x X X X x X X x x X X x X X X X X X X X X X x 0.5000 X X x X X X x X x X X X X X X X x X X x x X X X x X X X X X X X X X X X X X x 5 = = = = = = = = = = = = = = = = = = = = = 60 274.0 0.0690 5 95 3,392.0 0.0250 44 3,731 428.0 0.0690 44 1,299 63.0 0.4800 44 1331 63.0 0.5000 44 1,386 112.0 0.4000 44 1,971 27.0 0.4000 44 475 4 0,4000 44 70 350.0 0.0690 1.063 52.0 0.4000 44.= 1 144.0 0.4000 44 2,534 90.0 0.4000 44 1,584 282.0 0.0690 44= 856 150.0 0.5500 44= .63 6,292 260.0 0.5500 44 8�9 QO 44 1.,5 118.0 0.4000 44 2,077 142.0 0.0690 44 431 52.0 0.4000 44 915 72.0 01.4000 44=1267 24.0 . 0.4000 44 422 perimeter = 213.0 0.7300 44 6.842 erimeter = 53.0 0.7300 44 1,702 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 42 745 Infiltration: C TRX 1.064 X 3 392 X 12.50 x 0.354 / 60] X 44 = 11 698 Schedule Air Sensible ` Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 59,290 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: 24100 Page: 18 of 51 ROOM HEATING PEAK LOADS Project Title Bill and Rhonda Simmons Date 12/22/2006 Room Information Desian Conditions Room Name Guest Bedrooms Time of Peak Jan 12 am Floor Area 1,275 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF 0.0250 Conduction Area x x X X X X x X X X X X x X x x x x x x x x x x x x x x x x x x x x x x x x x U -Value x X X X X X X x X X x X X x X X x x X x x x x x x x x x x x x x x x x x x x x AT of = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr 1275.0 0.0250 44 1,402 389.0 0.0690 44 1,181 4.0 0.4000 44 70 4.0 0.4000 44 70 4.0 0.4000 44 70 4.0 0.4000 44 70 4.0 0.4000 44 70 4.0 0.4000 44 70 2 0.48 44 1,521 280.5 0.0690 852 72.0 0.4800 44 52] 4.5 0.4000 44 79 36.0 0.4000 44 634 72.0 0.4800 44 1,521 393.0 0.0690 44= 9.3 27.0 0.4000 44 475 35.6-0. 0_Q690 44 08 54.0 0.4000 44=950 perimeter = 139.0 0.7300 44 4,465 perimeter = 35.0 0.7300 44 1,124 Items shown with an asterisk (•) denote conduction through an interior surface to another room. Page Total: 18 421 Infiltration: [ 1.00 x 1.064 x 1 275 x 10.00 x 0.442 / 60] x 0 = 4 397 Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 23,396 EnergyPro 4.0 by EnergySoft User Number. 3665 Job Number. 24100 Page: 19 of 51 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Bill and Rhonda Simmons 12/22/2006 Room Information Desicin Conditions Room Name: HVAC #1 Outdoor Dry Bulb Temperature: 78OF Floor Area: 1,192 sf Outdoor Web Bulb Temperature: 1120F Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr R-21 Wall R-21 Wall North 1,192.0 x x x x x x x x x x x x 0.0173 x x x x x x x x x x x x 56.0 = = = = = = = North 290.0 0.0690 25.0 East 88.0 0.0690 32.3 South 243.0 0.0690 27.7 West 385.0 0.0690 32.1 0.0 25.4 South 0.0 20.6 4.0 23.3 South 72.0 20.6 0.0 23.3 West 14.3 20.6 66.7 37.7 West 0.0 20.6 4.0 37.7 Items shown with an asterisk (-) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration FxdWdw rage I otal -Orientation Btu/hrP Shaded Area x x x x x x x x x x x GLF + + + + + + + + + + + Unshaded Area x x x x x x x x x x x Page GLF = = = = = = = = East 24.1 21.5 47.9 39.4 South 59.0 20.6 0.0 23.3 South 144.0 22.9 0.0 25.4 South 0.0 20.6 4.0 23.3 South 72.0 20.6 0.0 23.3 West 14.3 20.6 66.7 37.7 West 0.0 20.6 4.0 37.7 Total 1,155 500 196 464 852 3,1671 Btu/hr Internal Gain Btu/hrP Occu ants P Ell x Occupants x 230 Btuh/occ. = 920 Equi ment x Dwelling Units x 1,6001 Watts/sqft = 1,6001 Infiltration: 1.064 x 1.16 x 75.53 .x 34 = 3176 Air Sensible CFM ELA Z�'T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,319 Latent Gain Btu/hr Occu ants ® x Occupants x 200 Btuh/occ. = 800 Infiltration: 4,771 x 1.16 x 75.53 x 1 1102 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,902 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: 24100 Page: 20 of 51 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Bill and Rhonda Simmons 2/22/2006 Room Information Desicin Conditions Room Name: Living Area Outdoor Dry Bulb Temperature: 78OF Floor Area: 3,392 sf Outdoor Web Bulb Temperature: 1120F Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F opaque surraces 'Solid Wood Door 'R-21 Wall R-38 Roof R-21 Wall Solid Wood Door R-21 Wall R-21 Wall R-21 Wall Orientation Area Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration FxdWdw IsDr U -Factor CLTD 1 Btu/hr x x x x x x x x x X x x 0.5000 X X X X x X X X x X x x 7.0 = = = = = = = = = = = 84 0.0690 7.0 132 0.0173 56.0 3,286 0.0690 25.0 738 0.5000 25.0 788 0.0690 32.3 781 0.0690 27.7 538 0.0690 32.1 314 20.6 4.0 24.3 East 17.4 20.6 34.6 39.7 East 32.1 20.6 111.9 Page Total 1 6 661 Orientation . Shaded Area x x x X X X x X X x Ix GLF + + + + + + + + + + + Unshaded Area x X X X X x x x x x x Page GLF = = = = = = = = = = North 0.0 21.5 63.0 24.9 North 0.0 20.6 112.0 24.3 North 0.0 20.6 27.0 24.3 North 0.0 20.6 4.0 24.3 East 17.4 20.6 34.6 39.7 East 32.1 20.6 111.9 39.7 East 0.0 20.6 90.0 39.7 South 150.0 22.9 0.0 25.4 South 260.0 22.9 0.0 25.4 South 0.0 21.5 85.0 24.0 Total Btu/hr Internal Gain Btu/hr Occup ants 4 x Occu ants x 230 Btuh/occ. = 920 E ui ment 1 p x Dwelling Units x 1,6001 Watts/sgft = 1 600 Infiltration: 1.064 x 1.16 x 214.92 x 0 = 9039 Air Sensible CFM ELA Z�'T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 54,763 Latent Gain Btu/hr Occu ants F 4 Occupants x 200 Btuh/oCC. = 800 Infiltration: 4,771 x 1.16 x 214.92 x 0.00263 = 3137 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,937 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: 24100 Page: 21 of 51 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Bill and Rhonda Simmons 2/22/2006 Room Information Design Conditions Room Name: Living Area Outdoor Dry Bulb Temperature: 780F Floor Area: 3,392 sf Outdoor Web Bulb Temperature: 1120F Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F e 5urtaces Orientation Area U -Factor CLTD 1 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain Occupants 4 E ui ment 1 rage I otal Orientation x x x x x x x x x x x x x + + + + + + + + + + + Unshaded Area x X x x x x x x x x x x South x 20.6 118.0 23.3 x 13.2 x 38.8 37.7 West x 20.6 x 37.7 West 0.0 x 24.0 x x x x x x x x x x x x x x J x Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain Occupants 4 E ui ment 1 rage I otal Orientation Shaded Area x x x x x x x x x x x GLF + + + + + + + + + + + Unshaded Area x X x x x x x x x x x GLF South 0.0 20.6 118.0 23.3 West 13.2 20.6 38.8 37.7 West 14.6 20.6 57.4 37.7 West 0.0 20.6 24.0 37.7 Page Total Btu/hr _ 0 Btu/hr Btu/hr x Occupants x 230 Btuh/oCC. = 920 x Dwelling Units x 1,6001 Wafts/sqft = 1,6001 Infiltration: 1.064 x 1.16 x 214.92 x 34 = 9039 Air Sensible CFM ELA &T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 54,76j Latent Gain Btu/hr Occupants r4 X Occupants x 200 Btuh/oCC. = 800 Infiltration: 4,771 x 1.16 x 214.92 x 0.00263 = 3137 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,937 EnergyPro 4.0 by EnergySoft User Number. 3665 Job Number. 24100 Page: 22 of 51 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Bill and Rhonda Simmons 12/22/2006 Room Information Desion Conditions Room Name: Guest Bedrooms Outdoor Dry Bulb Temperature: 780F Floor Area: 1,275 sf Outdoor Web Bulb Temperature: 1120F Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F Opaque Surfaces R-21 Wall Orientation Area x X X X X x x X x x x x U -Factor X X X X X x x x x x x x CLTD 1 = = = = = = = = = = = North 1,275.0 0.0173 56.0 North 389.0 0.0690 25.0 East 280.5 0.0690 32.3 South 393.0 0.0690 27.7 West 356.0 0.0690 32.1 20.6 4.0 24.3 North 0.0 20.6 4.0 24.3 North 0.0 20.6 4.0 24.3 North 0.0 21.5 72.0 24.9 East 32.4 21.5 39.6 39.4 East 0.0 20.6 4.5 39. Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration IFxdWdw (D) I Page Total Orientation Shaded Area x X x X X x x x x x20.6 x GLF + + + + + + + + + +E24l + Unshaded Area x X x x x x x x x x x Page GLF = = = = = = = _ = North 0.0 20.6 4.0 24.3 North 0.0 20.6 4.0 24.3 North 0.0 20.6 4.0 24.3 North 0.0 20.6 4.0 24.3 North 0.0 20.6 4.0 24.3 North 0.0 20.6 4.0 24.3 North 0.0 21.5 72.0 24.9 East 32.4 21.5 39.6 39.4 East 0.0 20.6 4.5 39. East 12.0 39.7 Total Btu/hr 1,235 671 626 750 788 4,070 Btu/hr Internal Gain Btu/hr Occupants 4 x Occupants x 230 Btuh/occ. = 920 E uipment , X Dwelling Units x 1,6001 Wafts/sqft = 1,6001 Infiltration: 1.064 x 1.16 x 80.78 x = 3,3Q8 Air Sensible CFM ELA Z�'T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,920 Latent Gain Btu/hr Occu ants x Occupants x 20701 Btuh/occ. = 800 Infiltration: 4,771 x 1.16 x 80.78 x 0.00263 = 1179 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,979 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: 24100 Page: 23 of 51 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date Bill and Rhonda Simmons 2/22/2006 Room Information Desicin Conditions Room Name: Guest Bedrooms Outdoor Dry Bulb Temperature: 780F Floor Area: 1,275 sf Outdoor Web Bulb Temperature: 1120F Indoor Dry Bulb Temperature: 78 of Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD ' Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain Nage I otal 0 Orientation x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x + + + + + + + + + + + Unshaded Area x X X x x x x x x x x Page GLF = = = = = = — = = = = Btu/hr East 32.4 21.5 39.6 39.4 2,257 South 0.0 20.6 27.0 23.3 629 West 0.0 20.6 54.0 37.7 2,037 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain Nage I otal 0 Orientation Shaded Area x x x x x x x x x x x GLF + + + + + + + + + + + Unshaded Area x X X x x x x x x x x Page GLF = = = = = = — = = = = Btu/hr East 32.4 21.5 39.6 39.4 2,257 South 0.0 20.6 27.0 23.3 629 West 0.0 20.6 54.0 37.7 2,037 4,9231 Total Btu/hr Occupants X Occupants x 230 Btuh/occ. = 920 q_p x Dwelling Units x 1,6001 Watts/sqft = 1,6001 Infiltration: 1.064 x 1.16 x 80.78 x 0 = 3 398 Air Sensible CFM ELA W TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,920 Latent Gain Btu/hr Occu ants 0 X Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.16 X 80.78 X 0.00263 = 1179 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,979 B4 E ui ment 1 EnergyPro 4.0 by EnergySoft User Number. 3665 Job Number: 24100 Page: 24 of 51