Loading...
BRES2017-0025 Revision 1Zz,Q�r� Project Address:s-1/ -7Zo APN #: Aplicant:Name: Address: C'>_� City, ST, Zip: Telephone: =F 61-0- P�� Email: C .6 f] , COD Arch/Eng Name: Address: City, St, Zip Telephone: Email: State Lie: City Bus Lie: PERMIT # 01twoni■ &-V— I PLAN LOCATION: Project Description. Pool, Remodel, Add't, Elect, Plumb, Mech C— l Sc 000S /y nQD r� aloation of Project Construction Type: Grading: Bedrooms: i Stories: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 Occupancy: # Units: FEB 15 Z019 UI I Y Ur Lim Wviry I rx BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 3 S wilg CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation DateITime: 13:21, Thu, Jan 31. 2019 Calculation Description: Title 24 Analysis Input File Name: Rosini 4.ribd16x CF1 R-PRF-01 Page 1 of 8 GENERAL INFORMATION 01 Project Name Single Family Residence 02 Calculation Description Title 24 Analysis 03 Project Location 54-720 Avenida Carranza 04 City La Quints 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3 1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 1979 15 Number of Zones 1 16 Slab Area (ft) 1979 17 Number of Stories 1 18 Addition Cond. Floor Area(ftz) n/a 19 Natural Gas Available No 20 Addition Slab Area (ftz) n/a 21 Glazing Percentage (%) 14.5 % COMPLIANCE RESULTS 01 Building Compiles with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building Incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDVlft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 1 97 488 -2.91 -147.7 % Space Cooling 85.04 77.72 7.32 8 6 % IAO Ventilation 1 16 1.16 0.00 0.0 % Water Heating 1251 14.34 -1.83 -14.6% Photovoltaic Offset -- 0.00 0.00 -- Compliance Energy Total 100.68 98.10 2.58 2.6% Registration Number: 419-P010009960A-000-000-0000000-0000 Registration Dale/Time: 01/31/2019 13:36 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 wVENiDA c14e� VT9 �R- 6-s za r7- 00 2s HERS Provider: CHEERS Report Generated at: 2019-01-31 13:21.58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation DatelTime: 13:21. Thu, Jan 31, 2019 Calculation Description: Title 24 Analysis Input File Name: Rosini 4.ribdl6x CF1 R-PRF-01 Page 2 of 8 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may Instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards Is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building Is provided for Information. Similarly, the EDR score of the Proposed Design Is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 53.2 52.2 0.0 62.2 ❑ Design meets Tier 1 requirement of 15 % or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30 % or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family In climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering NEM rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Insulation below roof deck • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airnow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: --None-- Registration Number: 419-P010009960A-000-000-0000000-0000 Registration DateMme: 01/31/2019 13:36 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162049-1149 HERS Provider: CHEERS Report Generated at: 2019-01-31 13:21.58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Single Family Residence Calculation DatelTime: 13:21, Thu, Jan 31, 2019 Page 3 of 6 Calculation Description: Title 24 Analysis Input File Name: Rosini 4.ribd16x BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ftz) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Single Family Residence 1979 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ftz) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Whole House Conditioned Whole Houset 1979 10 DHW Sys 1 n/a OPAQUE SURFACES 01 02 03 04 05 06 07 OB Name Zone Construction Azimuth Orientation Gross Area (ftz) Window 8, Door Area (ft) Tilt (deg) Front Wall Whole House R-21 Wall 270 Front 400 105 90 Left Wall Whole House R-21 Wall 0 Left 400 78 90 Rear Wall Whole House R-21 Wall 90 Back 400 64.8024 90 Right Wall Whale House R-21 Wall 180 Right 300 40 90 Roof Whole House R-51 Roof n/a n/a 1979 n/a n/a ATTIC 01 02 03 05 O6 08 Name Construction �04 Type Roof Reflectance Roof Emittance RadiaCoolRoof �!t Attic Whole House Attic RcofWhole House Ventilated 01 0.85 No Registration Number: 419-P010009960A-000-000-0000000-0000 Registration Date/Time: 01/31/2019 13:36 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-31 13:21:58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Single Family Residence Calculation DaterTime: 13:21, Thu, Jan 31, 2019 Page 4 of 8 Calculation Description: Title 24 Analysis Input File Name: Rosini 4.ribdl6x FENESTRATION I GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading Window Window Front Wall (Front-270) 9.0 9.0 1 81.0 038 0.30 Insect Screen (default) Window 2 Window Front Wall (Front-270) 3.0 8.0 1 24.0 0-34 0.30 Insect Screen (default) Window 3 Window Left Wall (Left-0) -- ---- 1 8-0 0,44 024 Insect Screen (default) Window 4 Window Left Wall (Left-0) --- ---- 1 16.0 0.47 0.24 Insect Screen (default) Window 5 Window Left Wall (Left-0) -•- - 1 12.5 0,47 0.24 Insect Screen (default) Window 6 Window Left Wall (Left-0) 1 12.5 0.47 0.24 Insect Screen (default) Window 7 Window Left Wall (Left-0) --- --- 1 125 0.47 024 Insect Screen (default) Window 8 Window Left Wall (Left-0) --- - 1 125 0.47 024 Insect Screen (default) Window 9 Window Left Wall (Left-0) 1 4.0 0.35 0-25 Insect Screen (default) Window 10 Window Rear Wall (Back-90) ---• -- 1 90 047 0.24 Insect Screen (default) Window 11 Window Rear Wall (Back-90) -- -- 1 60 035 0.25 Insect Screen (default) Window 12 Window Rear Wall (Back-90) 1 9.0 0.47 0.24 Insect Screen (default) Window 13 Window Rear Wall (Back-90) ---- --•- 1 6.0 0.35 0,25 Insect Screen (default) Window 14 Window Rear Wall (Back-90) 3.0 4.5 1 13.5 0.35 0-25 Insect Screen (default) Window 15 Window Rear Wall (Back-90) 2.8 8.0 0 951 21.3 0.32 0-30 Insect Screen (default) Window 16 Window Right Wall (Right-180) 2.5 50 1 125 0.47 024 Insect Screen (default) Window 17 Window Right Wall (Right-180) -- •-- 1 125 0.47 0.24 Insect Screen (default) Window 18 Window Right Wall (Right-180) 1 3.0 0.50 023 Insect Screen (default) Window 19 Window Right Wall (Right-180) •-•- -•-• 1 3.0 0.35 025 Insect Screen (default) Window 20 Window Right Wall (Right-180) 1 3.0 0.35 025 Insect Screen (default) Window 21 Window Right Wall (Right-180) •--- -- 1 30 035 025 Insect Screen (default) Window 22 Window Right Wall (Right-180) 1 3.0 0.47 024 Insect Screen (default) Registration Number: 419-P01000996OA-000-000-0000000-0000 Registration Date/Time: 01/31/2019 13:36 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance ReportVersion - CFl R-01162019-1149 Report Generated at: 2019-01-31 13:21:58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Single Family Residence Calculation DatelTime: 13:21, Thu, Jan 31, 2019 Page 5 of 8 Calculation Description: Title 24 Analysis Input File Name: Rosini 4.ribdl6x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 1 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Wndow B 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 2 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Window 14 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Wndow 15 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 16 8 0.1 8 8 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Construction Name Surface Type Construction Type Framing Total Cavity R-value Winter Design U-factor Assembly Layers Attic RoofWhole House Attic Roofs Wood Framed Ceiling 2x4 Top Chord of Roof Truss 24 in. O.C. R 13 0.078 Around Roof Joists: R-0-0 insul • Cavity/Frame:R-13.0/2x4Top Chrd Roof Deck: Wood Siding/sheathing/decking Roofing: Light Roof(Asphalf Shingle) R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 in 5-1/2 in. cavity (R-1 B) 0.074 • Inside Finish: Gypsum Board Cavity/Frame: R-19 in 5-12 in (R-16) 12x6 Exterior Finish: 3 Coat Stucco R-51 Roof Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 • Inside Finish: Gypsum Board Cavity/Frame: R-9 1 /2x4 Over Ceiling Joists: R-28.9 insul SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ftZ) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade Whole House 1979 485 None 1 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required nla Registration Number: 419-P010009960A-000-000-0000000-0000 Registration DatefTime: 01/31/2019 13:36 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFt R-01162019-1149 Report Generated at: 2019-01-31 13:21:56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Single Family Residence Calculation DatelTime: 13:21, Thu, Jan 31, 2019 Page 6 of 8 Calculation Description: Title 24 Analysis Input File Name: Rosini 4.ribdl6x WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (% ) DHW Sys 1 DHW Standard DHW Heater 1 (1) 1 0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor I Energy Factor I Efficiency Input Rating Pilot I Thermal Efficiency I Tank Insulation R-value (Int1l I) Standby Loss 1 Recovery Eff First Hour Rating I Flow Rate NEEA Heat Pump Brand I Model I Other Tank Location or Ambient Condition DHW Heater 1 Gas Small Storage 1 50 0.8 EF <= 75 kBtu/hr R-O/R-0 0 nla nla n/a SPACE CONDITIONING SYSTEMS 01 02 03 D4 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Whole Housel Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Healing Component 1 CntrlFurnace 1 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required Registration Number: 419-P010009960A-000-000-0000000-0000 Registration Date/Time: 01/31/2019 13:36 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-31 13:21 :56 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Single Family Residence Calculation DatelTime: 13:21, Thu, Jan 31, 2019 Page 7 of 8 Calculation Description: Ttle 24 Analysis Input File Name: Rosini 4.ribd16x HVAC- DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-disc Required 50 Not Required Not Required Not Required Not Required n/a HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 058 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM - IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVenlRpl 50 0.25 Default 0 Required Registration Number: 419-P010009960A-000-000-0000000-0000 Registration Date/Time: 01/31/2019 13:36 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-31 13:21 58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE' METHOD Project Name: Single Family Residence Calculation DaterTime: 13:21, Thu, Jan 31. 2019 Calculation Description: Title 24 Analysis Input File Name: Rosini 4.ribdl6x CF1R-PRF-01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Joan Hacker Joa*VNacker Company: Signature Date: Joan Hacker 01/31/2019 Address: CEA/HERS Certification Identification (If applicable): 72875 Fred Waring Drive City/Slate0p: Phone: Palm Desert, CA 92260 760-345-1352 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penally of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations, 3. ' The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Joan Hacker Joa. Packer Company: Date Signed: Joan Hacker 01/31/2019 Address: License: 72875 Fred Waring Drive City/State/Zip: Phone: Palm Desert, CA 92260 760-345-1352 Digitally signed by CHEERS—, This digital signature is provided in order to secure the content or this registered document, and in no way implies Registration ProOderresporfs+bldty for the accuracy of the information. Registration Number: 419-P010009960A-000-000-0000000-0000 Registration Date/Time: 01/31/2019 13:36 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-31 13 21:58