BRES2017-0025 Revision 1Zz,Q�r�
Project Address:s-1/ -7Zo
APN #:
Aplicant:Name:
Address: C'>_�
City, ST, Zip:
Telephone: =F 61-0- P��
Email: C .6 f] , COD
Arch/Eng Name:
Address:
City, St, Zip
Telephone:
Email:
State Lie:
City Bus Lie:
PERMIT # 01twoni■ &-V— I
PLAN LOCATION:
Project Description. Pool, Remodel, Add't, Elect, Plumb, Mech
C— l Sc 000S
/y nQD
r�
aloation of Project
Construction Type:
Grading:
Bedrooms: i Stories:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
Occupancy:
# Units:
FEB 15 Z019
UI I Y Ur Lim Wviry I rx
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE 3 S wilg
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation DateITime: 13:21, Thu, Jan 31. 2019
Calculation Description: Title 24 Analysis Input File Name: Rosini 4.ribd16x
CF1 R-PRF-01
Page 1 of 8
GENERAL INFORMATION
01
Project Name
Single Family Residence
02
Calculation Description
Title 24 Analysis
03
Project Location
54-720 Avenida Carranza
04
City
La Quints
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3 1 (1149)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.2
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
270
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft)
1979
15
Number of Zones
1
16
Slab Area (ft)
1979
17
Number of Stories
1
18
Addition Cond. Floor Area(ftz)
n/a
19
Natural Gas Available
No
20
Addition Slab Area (ftz)
n/a
21
Glazing Percentage (%)
14.5 %
COMPLIANCE RESULTS
01
Building Compiles with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building Incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDVlft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
1 97
488
-2.91
-147.7 %
Space Cooling
85.04
77.72
7.32
8 6 %
IAO Ventilation
1 16
1.16
0.00
0.0 %
Water Heating
1251
14.34
-1.83
-14.6%
Photovoltaic Offset
--
0.00
0.00
--
Compliance Energy Total
100.68
98.10
2.58
2.6%
Registration Number: 419-P010009960A-000-000-0000000-0000 Registration Dale/Time: 01/31/2019 13:36
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149
wVENiDA c14e� VT9
�R- 6-s za r7- 00 2s
HERS Provider: CHEERS
Report Generated at: 2019-01-31 13:21.58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation DatelTime: 13:21. Thu, Jan 31, 2019
Calculation Description: Title 24 Analysis Input File Name: Rosini 4.ribdl6x
CF1 R-PRF-01
Page 2 of 8
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may Instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards Is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
Is provided for Information. Similarly, the EDR score of the Proposed Design Is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency
EDR of Proposed Efficiency EDR Value of Proposed PV + Battery
Final Proposed EDR
53.2
52.2 0.0
62.2
❑
Design meets Tier 1 requirement of 15 % or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30 % or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family In climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV)
renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified.
Notes:
• Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering NEM rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Insulation below roof deck
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airnow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
--None--
Registration Number: 419-P010009960A-000-000-0000000-0000 Registration DateMme: 01/31/2019 13:36
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162049-1149
HERS Provider: CHEERS
Report Generated at: 2019-01-31 13:21.58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Project Name: Single Family Residence Calculation DatelTime: 13:21, Thu, Jan 31, 2019 Page 3 of 6
Calculation Description: Title 24 Analysis Input File Name: Rosini 4.ribd16x
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ftz)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Single Family Residence
1979
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ftz)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Whole House
Conditioned
Whole Houset
1979
10
DHW Sys 1
n/a
OPAQUE SURFACES
01
02
03
04
05
06
07
OB
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ftz)
Window 8, Door Area (ft)
Tilt (deg)
Front Wall
Whole House
R-21 Wall
270
Front
400
105
90
Left Wall
Whole House
R-21 Wall
0
Left
400
78
90
Rear Wall
Whole House
R-21 Wall
90
Back
400
64.8024
90
Right Wall
Whale House
R-21 Wall
180
Right
300
40
90
Roof
Whole House
R-51 Roof
n/a
n/a
1979
n/a
n/a
ATTIC
01
02
03
05 O6 08
Name
Construction
�04
Type
Roof Reflectance Roof Emittance RadiaCoolRoof
�!t
Attic Whole House
Attic RcofWhole House
Ventilated
01 0.85 No
Registration Number: 419-P010009960A-000-000-0000000-0000 Registration Date/Time: 01/31/2019 13:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-31 13:21:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Single Family Residence Calculation DaterTime: 13:21, Thu, Jan 31, 2019 Page 4 of 8
Calculation Description: Title 24 Analysis Input File Name: Rosini 4.ribdl6x
FENESTRATION I GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
Window
Window
Front Wall (Front-270)
9.0
9.0
1
81.0
038
0.30
Insect Screen (default)
Window 2
Window
Front Wall (Front-270)
3.0
8.0
1
24.0
0-34
0.30
Insect Screen (default)
Window 3
Window
Left Wall (Left-0)
--
----
1
8-0
0,44
024
Insect Screen (default)
Window 4
Window
Left Wall (Left-0)
---
----
1
16.0
0.47
0.24
Insect Screen (default)
Window 5
Window
Left Wall (Left-0)
-•-
-
1
12.5
0,47
0.24
Insect Screen (default)
Window 6
Window
Left Wall (Left-0)
1
12.5
0.47
0.24
Insect Screen (default)
Window 7
Window
Left Wall (Left-0)
---
---
1
125
0.47
024
Insect Screen (default)
Window 8
Window
Left Wall (Left-0)
---
-
1
125
0.47
024
Insect Screen (default)
Window 9
Window
Left Wall (Left-0)
1
4.0
0.35
0-25
Insect Screen (default)
Window 10
Window
Rear Wall (Back-90)
---•
--
1
90
047
0.24
Insect Screen (default)
Window 11
Window
Rear Wall (Back-90)
--
--
1
60
035
0.25
Insect Screen (default)
Window 12
Window
Rear Wall (Back-90)
1
9.0
0.47
0.24
Insect Screen (default)
Window 13
Window
Rear Wall (Back-90)
----
--•-
1
6.0
0.35
0,25
Insect Screen (default)
Window 14
Window
Rear Wall (Back-90)
3.0
4.5
1
13.5
0.35
0-25
Insect Screen (default)
Window 15
Window
Rear Wall (Back-90)
2.8
8.0
0 951
21.3
0.32
0-30
Insect Screen (default)
Window 16
Window
Right Wall (Right-180)
2.5
50
1
125
0.47
024
Insect Screen (default)
Window 17
Window
Right Wall (Right-180)
--
•--
1
125
0.47
0.24
Insect Screen (default)
Window 18
Window
Right Wall (Right-180)
1
3.0
0.50
023
Insect Screen (default)
Window 19
Window
Right Wall (Right-180)
•-•-
-•-•
1
3.0
0.35
025
Insect Screen (default)
Window 20
Window
Right Wall (Right-180)
1
3.0
0.35
025
Insect Screen (default)
Window 21
Window
Right Wall (Right-180)
•---
--
1
30
035
025
Insect Screen (default)
Window 22
Window
Right Wall (Right-180)
1
3.0
0.47
024
Insect Screen (default)
Registration Number: 419-P01000996OA-000-000-0000000-0000 Registration Date/Time: 01/31/2019 13:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance ReportVersion - CFl R-01162019-1149 Report Generated at: 2019-01-31 13:21:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Project Name: Single Family Residence Calculation DatelTime: 13:21, Thu, Jan 31, 2019 Page 5 of 8
Calculation Description: Title 24 Analysis Input File Name: Rosini 4.ribdl6x
OVERHANGS AND FINS
01
02 03 04 05 06
07 08 1 09 10
11 12 13 14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
Wndow
B
0.1
8
8
0
0
0
0
0
0
0
0
0
Window 2
6
0.1
6
6
0
0
0
0
0
0
0
0
0
Window 14
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Wndow 15
8
0.1
8
8
0
0
0
0
0
0
0
0
0
Window 16
8
0.1
8
8
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
R-value
Winter Design
U-factor
Assembly Layers
Attic RoofWhole House
Attic Roofs
Wood Framed Ceiling
2x4 Top Chord of Roof Truss 24
in. O.C.
R 13
0.078
Around Roof Joists: R-0-0 insul
• Cavity/Frame:R-13.0/2x4Top Chrd
Roof Deck: Wood Siding/sheathing/decking
Roofing: Light Roof(Asphalf Shingle)
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19 in 5-1/2 in.
cavity (R-1 B)
0.074
• Inside Finish: Gypsum Board
Cavity/Frame: R-19 in 5-12 in (R-16) 12x6
Exterior Finish: 3 Coat Stucco
R-51 Roof
Ceilings (below
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
• Inside Finish: Gypsum Board
Cavity/Frame: R-9 1 /2x4
Over Ceiling Joists: R-28.9 insul
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ftZ)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Slab -on -Grade
Whole House
1979
485
None
1
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02 03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation Building Envelope Air Leakage
CFM50
Not Required
Not Required Not Required
nla
Registration Number: 419-P010009960A-000-000-0000000-0000 Registration DatefTime: 01/31/2019 13:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFt R-01162019-1149 Report Generated at: 2019-01-31 13:21:56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Single Family Residence Calculation DatelTime: 13:21, Thu, Jan 31, 2019 Page 6 of 8
Calculation Description: Title 24 Analysis Input File Name: Rosini 4.ribdl6x
WATER HEATING SYSTEMS
01
02 03 04
05
06
Name
System Type Distribution Type Water Heater
Number of Heaters
Solar Fraction (% )
DHW Sys 1
DHW Standard DHW Heater 1 (1)
1
0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Name
Heater
Element
Type
Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor I Energy
Factor I Efficiency
Input Rating
Pilot I
Thermal
Efficiency
I Tank
Insulation
R-value
(Int1l I)
Standby
Loss 1
Recovery
Eff
First Hour
Rating I
Flow Rate
NEEA Heat Pump
Brand I Model I
Other
Tank Location
or Ambient
Condition
DHW Heater 1
Gas
Small Storage
1
50
0.8 EF
<= 75 kBtu/hr
R-O/R-0
0
nla
nla
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
D4
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
Whole Housel
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01 02
03
04
Name System Type
Number of Units
Efficiency
Healing Component 1 CntrlFurnace
1
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04 05
06
07
08
Name
System Type
Number of Units
Efficiency
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
13
16
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Registration Number: 419-P010009960A-000-000-0000000-0000 Registration Date/Time: 01/31/2019 13:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-31 13:21 :56
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Single Family Residence Calculation DatelTime: 13:21, Thu, Jan 31, 2019 Page 7 of 8
Calculation Description: Ttle 24 Analysis Input File Name: Rosini 4.ribd16x
HVAC- DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-disc
Required
50
Not Required
Not Required
Not Required
Not Required
n/a
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
058
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
-
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVenlRpl
50
0.25
Default
0
Required
Registration Number: 419-P010009960A-000-000-0000000-0000 Registration Date/Time: 01/31/2019 13:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-31 13:21 58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE' METHOD
Project Name: Single Family Residence Calculation DaterTime: 13:21, Thu, Jan 31. 2019
Calculation Description: Title 24 Analysis Input File Name: Rosini 4.ribdl6x
CF1R-PRF-01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Joan Hacker
Joa*VNacker
Company:
Signature Date:
Joan Hacker
01/31/2019
Address:
CEA/HERS Certification Identification (If applicable):
72875 Fred Waring Drive
City/Slate0p:
Phone:
Palm Desert, CA 92260
760-345-1352
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penally of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations,
3. ' The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Joan Hacker
Joa. Packer
Company:
Date Signed:
Joan Hacker
01/31/2019
Address:
License:
72875 Fred Waring Drive
City/State/Zip:
Phone:
Palm Desert, CA 92260
760-345-1352
Digitally signed by CHEERS—, This digital signature is provided in order to secure the content or this registered
document, and in no way implies Registration ProOderresporfs+bldty for the accuracy of the information.
Registration Number: 419-P010009960A-000-000-0000000-0000 Registration Date/Time: 01/31/2019 13:36 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-31 13 21:58