Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BRES2018-0267
78-495 CALLE TAMPICO Tw�p D VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 11/19/2018 Permit Type/Subtype: BUILDING RESIDENTIAL/DWELLING -SINGLE FAMILY DETACHED Owner: Application Number: BRES2018-0267 GREG & KRISTEN CHAPMAN Property Address: 80129 VIA PESSARO ttv APN: 777210026 LA QUINTA, CA 0 N Application Description: CHAPMAN / 4,900SF DWELLING/VB/R-3/CLASS A-FR/SPRINKLED z Property Zoning: Q' �1�12J Application Valuation: $418,308.00 m O oQ Applicant: Contractor: NICK NAREZ / MICHAELJEHA CONSTRUCTION MICHAELJEHA CONS?IgTION 53408 VIA PISA 53408 VIA PISA 8 � _v LA QUINTA, CA 92253 LA QUINTA, CA 922 av W (925)250-4038 M LJc. No.: 410408 z LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000} of Division 3 of the Business and Professions Code, and my License is in full force and effect. ■License Class: B License No.: 410408 Date: Contract OWNER -BUILDER DECLARAT� I hereby affirm under penalty of perjury that I am exam t from the antractor's State License Law for the following reason (Sec. 7031.5, Busine and ofessions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: EXEMPT I Number: _ rt that in the performance of the work for which this permit is issued, I shall employ ny person in any manner so as to become subject to the workers' compe sation la s of California, and agree that, if I should become subject to the workers nsation provisions of Section 3 a th Code, I shall forthwith complyjjwith those provisions. 46 L� '-/#10� Appllcant.' WARNING: FAILURE TO SECURE WORKERS' COMPEN ATION COV AGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PE ALTIES AV CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN DITI TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and ate laws relating to building construction, and hereby authorize representativ o this city enter u an the above -mentioned property for inspectipn purp ses. Date ignature (Applicant orAgenLj: Dat_: 11J19/2018 Application Number: BRES2018-0267 Property Address: 80129 VIA PESSARO APN: 777210026 Application Description: CHAPMAN / 4,900SF DWELLING/VB/R-3/CLASS A-FR/SPRINKLED Property Zoning: Application Valuation: $418,308.00 Applicant: NICK NAREZ / MICHAELJEHA CONSTRUCTION 53408 VIA PISA LA QUINTA, CA 92253 Owner: GREG & KRISTEN CHAPMAN LA QU I NTA, CA 0 Contractor: MICHAEL JEHA CONSTRUCTION 53408 VIA PISA LA QU I NTA, CA 92253 (925)250-4038 Llc. No.: 410408 Detail: 4,900SF SINGLE FAMILY DWELLING [VB/RES-3/CLASS A-FR/SPRINKLED] THIS PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL, SPA, BBQ, FIRE PITS OR DRIVEWAY APPROACH. 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT CITY AMOUNT ART IN PUBLIC PLACES - RESIDENTIAL 270-0000-43201 0 $545.77 Total Paid for ART IN PUBLIC PLACES - AIPP: $545.77 DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $17.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $17.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - LIBRARIES 253-0000-43200 0 $344.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - PARKS/REC 251-0000-43200 0 $2,048.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 DESCRIPTION ACCOUNT QTY AMOUNT TEMP POWER SERVICE 101-0000-42403 0 $26.01 DESCRIPTION ACCOUNT QTY AMOUNT TEMP POWER SERVICE PC 101-0000-42600 0 $18.20 Total Paid for ELECTRICAL: $44.21 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $66.30 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $27.30 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $156.04 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $51.49 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $301.13 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT>7KSF 101-0000-42408 0 $39.01 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF PC 101-0000-42600 0 •-$195.C5 Total Paid for GRADING: $234.06 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $195.05 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $130.05 DESCRIPTION ACCOUNT QTY AMOUNT EXHAUST HOOD 101-0000-42402 0 $13.00 DESCRIPTION ACCOUNT QTY AMOUNT EXHAUST HOOD PC 101-0000-42600 0 $5.20 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE 101-0000-42402 0 $195.05 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE PC 101-0000-42600 0 $130.05 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN 101-0000-42402 0 $130.00 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN PC 101-0000-42600 0 $52.00 Total Paid for MECHANICAL: $850.40 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PERMIT 101-0000-42400 0 $759.31 Total Paid for NEW CONSTRUCTION PERMIT: $759.31 DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($1,200.00) DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,200.00 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $428.57 Total Paid for NEW CONSTRUCTION PLAN CHECK: $428.57 DESCRIPTION ACCOUNT QTY AMOUNT PLAN CHECK DEPOSIT - RESIDENTIAL 101-0000-42600 1 $1,200.00 Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $1,200.00 DESCRIPTION ACCOUNT QTY AMOUNT BACKFLOW DEVICE 101-0000-42401 0 $13.00 DESCRIPTION ACCOUNT QTY AMOUNT BACKFLOW DEVICE PC 101-0000-42600 0 $5.20 DESCRIPTION ACCOUNT QTY AMOUNT BUILDING SEWER 101-0000-42401 0 $26.01 DESCRIPTION ACCOUNT QTY AMOUNT BUILDING SEWER PC 101-0000-42600 0 $18.20 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $403.00 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $403.00 DESCRIPTION ACCOUNT QTY AMOUNT ROOF DRAIN 101-0000-42401 0 $117.00 DESCRIPTION ACCOUNT QTY AMOUNT ROOF DRAIN PC 101-0000-42600 0 $117.00 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $13.00 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $7.80 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $13.00 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $13.00 Total Paid for PLUMBING FEES: $1,149.21 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $54.38 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $54.38 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT QTY AMOUNT SINGLE FAMILY DETACHED 2018 UPDATE 224-0000-20320 0 $2,310.00 Total Paid for TUMF - RESIDENTIAL: $2,310.00 $14,793.04 + PERMIT # BAgm PLAN LOCATION - Project Address: J�Y'y Pe5sc� Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: � eW �a wt C_ L� GI d 1 i/l►� �►� Applicant Name: Address: City, ST, Zip: Telephone: Email: Valuation of Project $ 1 Contractor Name: `)P C ��A w,, Ld New SFD Construction: Address: S 3 L city, st, zip 1 a, Telephone: G 25- 2 s-v ` e�v Email: co^^ State Lic: L/l0 yo City Bus Lic: -o2� Conditioned Space SF Garage SF Patio/Porch SF Fire Sprinklers J SF Arch/Eng Name: � �. Construction Type: Occupancy: Address: 0301( 2ve✓1 L j Grading: City, St, Zip Telephone: •3 Il Z0 60swq Bedrooms: Stories: # Units: Email: �veq 11tcAvvi[ A (• LC� vti State Lic:'' City Bus Lic: Property Owner's Name: 1�.v2 YtS�C� �� New Commercial / Tenant Improvements: Address: Total Building SF City, ST, Zip Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QU I NTA, CA 92253 760-777-7000 Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVF.T.OPF.R FF.F.S PATD AREA: AMOUNT LEVEL ONE AMOUNT I LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMIIND. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: The Hideaway Owner's Name: Greg & Kristen Chapman Project Address: 80-129 Via Pessaro, LaQuinta Project Description: SFD APN: 777-210-026 Tract #: Type of Development: Residential Xx Commercial Total Square Feet of Building Area: 4,900 s . ft. Date: November 19, 2018 Phone No. 925-250-4038 Lot #'s: Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she ' u ized to sign on behalf of the owner/developer. Dated: November 19, 2018 ********************************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABt ACCORDANCE WITH ONE OF THE FOLLOWING: (C Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code 65995 4900 $3.79 $18571.00 Building Permit Application Completed: Yes/No By: Larry Moen, Director Facilities Dev. & Pl Project Approval ***************************** T HAVE BEEN OR WILL BE SATISFIED IN Agreement Existing Not Subject to Fee Prior to 1/1/87 Requirement Note: Pursuant to AB 181 any room additions or enclosures of 500 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within the same school district's jurisdiction are exempt from developer fees. Certificate issued by: Laurie Howard, Administrative Spec. Signature: aG{/ �- NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90-day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90-day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. 11/2010 DOC 9 2017-0439417 RECORDING ti_:QUESIED SY: WFG Nauonel TW@ Company AND WHEN RECORDED MAIL TO: Greg a Kristin Chapman Family Trusl, dated April 12. 2002 1295 Saint Albans Road San Harino CA 91108 Order No,: 711b410 Escrow No.: F52352 A.P.N.: 777.210-026-0 TRA 020.160 10l23=17 01-18 PM Fees: $24.00 Page 1 of 4 Recorded in Official Records County of Rivers4e Peter Aidana Assessor -County Cleric -Recorder "This document was eledronically submit to Ure Cour4y of Riverside for recording» Reoeipled by: SONIA MI SPACE ABOVE I'1115 LINT IS FOR RECORDER'S USE GRANT DEED THE UNDERSIGNED GRANTOR(S) DECL.ARE(S) DOCUMENTARY TRANSFER TAX IS $ 621.50 [ X ] computed on full value of property convoyed, or [ ] computed on fill value seas value of liens or encumbrances remaining at tine of sate, ] unincorporated area [ X ] City of La Quint& FOR A VALUABLE CONSIDERATION, receipt of what is hereby acknowledgod, John W. Mayol and Tams Mayol, Trustees of The J 8 T Mayol Revocable Trust dated Dec, 15, 1998 hereby GRANT(S) to Gregory Chapman and Kristin Chapman, Trustees of the Greg 8, Kristin Chapman Family Trust, dated April 12, 2002 the following de salbed real property'6n the Cotinty of Riverslde, State of Ca,'Iornia Sce Exhibit 'A' attached hereto and made a part hereof, Commonly known as: 90129 %ra Pessaro, Vacant Lot 212, La Guinta, CA 92253 Dated: October 4, 2017 A notary public or other off•eer oarnpceting this cort1licate veilflea only t-* identity of Vie rndividwl wfv signed the document to whidi this oedf4ate Is attached, and not the truthfu:ness, accuracy. or vat:dity of tha. document, STATE OF' C IFORNIA COUNTY OFL-Vr'1ees on QLAx6x_-- lu la me, C,.4a ct _. a notary public, perscne y sc _4_4,rr,c-M who rcoved to r,a9 on the 1e-61 salisfvr.1ory evldan(e to be ,Ira ponmr.4,)►%bose narnetis) are s.abscrrbaci m,he within L �strurrient ar ackn to me that hr�i�sl ,111,ay ew.uw h*11' same in Aherir nuvior;red csfaB."ttytt) and that by hk*s 6rlthrx+ sl aturets) on :he instrument t`rs persan(s). or tl?a &.mity upon tm%half or which Ilia pumm(s) actea. executed The In3tncnent, I certify urder PENALTY OF PERJURY under the Iwvs of the Stale of Celifomia that the foreDoireg paragraph is true and comGc:l. We J & MaycA Revocable Trust dated Dec, 15, 199 SS. By: ah„ W. Mayol, Trustvo I A o.11° -tG q SyTerT 9`:CLrtiUiltA RODRIGUEZ Notary Ptac - Cahfornle stan,slaus County, } Cornrnlssson • 215a474 :' P Comm Ea otjun??.2020 WITNESS -kand and officia. seal. RECEIVED S,i�r=a %r ; n��++ (This area for off�?11fta 0 18 MAIL TAX STATEMENTS AS DIRECTED ABOVE CITY OF LA QUINTA DESIGN AND DEVELOPMENT DEPARTMENT tr� CERTIFIQ ION Under the provisions of Government code 27361.7 I certify the penalty of perjury that the following is a true copy of illegible wording found in the attached document: Print or a the a e number 5 and worcling below_ Acknowledgment Clarity _x_ Clarity Copy Attached Clarity Pant Below Place of execution: San Bernardino, CA Date: Signature 10/23/17 Print Name: David Ramsay Fde No. 7118419-LN Exhibit A Legal Description All that certain real property in the County of Riverside. Statc of California, described as follows' PARCEL I: LOT 213 OF AMENDED TRACT NO. 29894- 2. LN THE CITY OF LA QUINTA, COUNTY DF KWERSIDE. SPATE. OF CALIFORNIA. AS PEK MAP RECORDED IN BOOK 337. PAGES 56 MROl. GH 88_ INCLUSIVE OF MAPS. IN I -HE 01-FIC I~ OF THE COUNTY RECORDER OF SAID COUNTY. EXCLPrI.NG T111 LREFROM TO GRANTOR. AND ITS SIJCCESSL.IRS AND ASSIGNS. IN" I-ERES-I IN ALL WATER. MINERALS. 011.. GAS, PYTROLEl'IM.0-1 HER IIY1)ROC ARI30iti SI,JBS'1ANCES AND ALL. GEUTHERt+ AL ENERGY 1 01IRCLS IN OR LisDER SAID LAND OR WI IICH 1IAY BE: PRODUCED FRO4i SAID LAND. PARCEL NON-EXCLUSIVE FASENIENTS FOR ACCESS, INGRESS. EGRESS, DRAINA(JE. MiAINTEN_ NCE. REPAIRS AND FOR all IER PURPOSES. ALL AS DESCRIBED ICI TI IE DECLAR1 I ION RECORDED ON Df CEMBFR 13. 2W2 AS INSTR1:M NT NO.2002-745939. OF OFFICIAL RECORDS. APN : 777-210-026-0 Pge No. 2 mv-rx -nz • Imrr. Y I1GV--i ,n7Krem3t1ve rnmm,% V EsGil A, SAFEhuilt Company DATE: OCT. 29, 2018 ❑ APPLICANT ❑ JURIS. JURISDICTION: LA QUINTA PLAN CHECK #.: BRES2018-0267 SET: II PROJECT ADDRESS: 80-129 VIA PESSARO PROJECT NAME: SFR FOR CHAPMAN ❑ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. ® The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ❑ The applicant's copy of the check list has been sent to: ® EsGil staff did not advise the applicant that the plan check has been completed. ❑ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by Email: Mail Telephone Fax In Person ® REMARKS: Add roof truss plans & calculations to the list of deferred items on Sheet T-1.0. This is a structural review only, as per the building official's instructions. By: ALI SADRE, S.E. EsGil 10/24 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 RIVERSIDE COUNTY FIRE DEPARTMENT OFFICE OF THE FIRE MARSHAL CITY OF LA QUINTA 78-495 CALLE TAMPICO, LA QUINTA CA 92253 • PHONE (760)777-7000 *DIRECT (760)777-7074 REQUIRED FIRE FLOW Date: 1�F - 7 -16 Project Permit #: ew,5s201,5- 0.2 67 Project Name: <"y�F,?-;:oA,1 Project Address: go i-2 -? 66.4 c To whom it may concern, The City of La Quinta Fire Marshal's Office will require a fire flow of- OOOGPM at 20 PSI residual for a duration of —' hour(s wit without fire sprinklers. Please submit a fire flow report prepared by the local water purveyor to demonstrate that the values listed above are met. NOTE - (only applies if "without fire sprinklers" selection was made above): This is based out of Appendix B in the California Fire Code. A 50% reduction in fire flow listed above is allowed when the building is equipped with an automatic fire sprinkler system. Fire flow with this reduction shall not be less than 1000 / 1500 gallons per minute (based on type of fire sprinkler system.) Respectfully, 6���� Edgar Gonzalez Fire Safety Specialist ps OOUNTy F1A� R SHE PIhE 1J APPROVED Date:6/ I/ �- x �- Building Permit Number: Project Description: ISIFR Exempt: O (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Plan Submittal Date Job Site Address Owner's Name Number, Street, or PO Box City, State, Postal Code Owner's Phone Number Owner's E-Mail Address Project Manager's Name' Project Manager's Phone Number Project Manager's E-mail Address Builder / Contractor Number, Street or PO Box City, State, Postal Code Project Square Footage 5/9/2018 80129 Via Pessaro Greg Chapman 80129 Via Pessaro La Quinta, CA. 92253 c/o 925-250-4038 Mike Jeha 925-250-4038 ehaconslructionpaol, com Jeha Construction 53408 Via Pisa La Quinta, CA. 92253 Approx. 6,300 square feet City Approval By Renado Gouldlock-DEC/Burrtec Waste. Date of City Approval ti5 Materials To Be Discarded: Product Tons Trash 24.75 Not recyclable Product Tons Asphalt 0.00 Recyclable Masonry (broken) 0.00 Recyclable Brick/Block 0.00 Recyclable Plaster 7.25 Recyclable Cardboard 0,00 Recyclable Scrap Metal 0.00 Recyclable Commingled 0.00i ecyclable Tile (floor) 0.60 Recyclable Concrete 27.00 Recyclable Tile (roof) 0.80 Pecyclable Drywall 3.25 Recyclable Wood 8.50 Recyclable Donated / Reuse* 0.00 Recyclable Landscape Debris 0.00 Recyclable *Describe Items i otals: Recycle Trash 47.4 24.8 Projected Diversion: 65.70% I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner_ However, the DMP is still issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer Owner / Developer / Project Manager / Superintendant Date 1 I CITY OF LA QUINTA SUB-CONTRACTO LIST JOB ADDRESS " 1?-9 l � �i9� cal r0 PERMIT NUMBER _ OWNER „BUILDER This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous. place. Only 14rsons appearing on this list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work, Failure to comply will result in a stoppage of work and/or the voidance of building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an acceptable response. .:::::.::::...::..: ...... ..... .... . T ade:. _e �ssrfic ton Contr, ctnr r I I a 5�atr C r s .e e"':::. of tracta ..s L c. nse.- .......... W.orker.s :Com _nsatiori lrisuranre ' Gft Business: Eicens......,. Company Name Classification License Number Exp. Date Carrier Name Policy Number Exp. Date License Number Exp. Date (e.g. A, B, C-8) �[(xxxxxxxx) (xx/xx/xx) (e.g. State Fund, CalComp) �7 (Format Varies) 'xxtxx/xx) (xxxx) (xx/xx/xx) FIN.RTHWRIC IC. t�) ::::<::- I T A ICJ `7 ✓ l <6 o oOU�j�7UO �o Zr O (OZ3(afo 8 3r %� CC'.IV.GRETI ...C-B.). ::" �/G C $ Tz��G 3! ?.� t rim ��0 3 b�o2 OCl `T ! / Ol (�Cao� ( 4 3o I _.. r� .13 �� 9 zo�z� a e oow4(y 5 3r l7 FRAMING (C-5). ... STRUCT. STEEL{C:-SI.}:..: MASONRY (C=29) PLUMBING �c �s)' „ � G3� 92� 9S`� ��30- l��o � G(%�f%C �✓%� _ �'3/ /9 C� 10 iL($2 lc ao /8 LATIA, .PLASTER c:=�'�}' /SS l 1G C `���� 0 7AII;w ,$ D 5/3r 1 l9 DRYWALL (c 9) ?02 4A, l bmr, YArK C5750) 1 F, �5 3 FiVAC (C'20.) :':: -5l �%OiiD/�! ffl2 ELECTRICAL (C-1:a):... (o �1 `� d 3f 20 1R-e v 0 r�- LK 6, G ( 23 1 ®l �z� 13i —r 5H..EET::MI=TALI [f:'' ;. .FLOORING (C ....... ........ .. . ......... ..... ... ..-...-..--. I�ISU..L:ATIC.N;iC ':: -SEWAGEDISP. (C-42).:::.. PAINTING .(C:33} C ER�IM.. C 'Tf Li=:.(C-54} . ..:.::.::..::.......:.::::: E CABINETS (C=S) , . FENCING..:(C:-'I,3) I ;LANDSCAPING:=-(C.27).: :::. 000L C-53):$0 P,(L . >Vgew 10 �tL01 0 00i/`�W� 1 Ct � 3l e�UR�.'�.' C,4MPf�•e� �1 j BUILDING ENERGY ANALYSIS REPORT 1 PROJECT: Chapman Residence Lot 212 - The Hideaway - Via Pessaro La Quinta, CA 92253 Project Designer: Brock J. Payton, Inc. 8391 Beverly Blvd., Suite 482 Los Angeles, CA 90048 ((310) 720-6589 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 74-818 Velie Way, Suite #rDATE C�i� Palm Desert, CA 92260 OF L� QUINTA (760) 200-4780B UILDING DIVISION ED FOR CO CODE LI�CE �y �'8 • otb� JoeNuniber RECEIVED OCT 2 2 2018 Date: CITY OF LA QUINTA 10/9/2018 DESIGN AND DEVELOPMENT DEPARTMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. r- I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01 -E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 17 Form MF-1 R Mandatory Measures Summary 19 HVAC System Heating and Cooling Loads Summary 23 Zone Load Summary 28 Room Load Summary 33 Room Heating Peak Loads 38 Room Cooling Peak Loads 43 CERTIf TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE r ACID Project Name: Chapman Residence Cal-culation Daterrime: 08:44, Tue, Oct 09, 2018 Calculation Description: Title 24 Analysis Input File Name: Chapman Res -Lot 212-Hideaway-Payton 18.ribdl6x CF 1RF-01 Page 1 of 14 GENERAL INFORMATION 01 Project Name Chapman Residence 02 Calculation Description Title 24 Analysis 03 Project Location Lot 212 - The Hideaway -Via Pessaro 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 45 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 4900 15 Number of Zones 5 16 Slab Area (ft2) 4000 17 Number of Stories 2 18 Addition Cond. Floor Area(ft2) n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) n/a 21 Glazing Percentage (%) 25.7% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.97 1.72 1.25 42.1% Space Cooling 86.20 83.93 2.27 2.6% IAQ Ventilation 0.88 0.88 0.00 0.0% Water Heating 3.35 4.39 -1.04 -31.0% Photovoltaic Offset — 0.00 0.00 --- Compliance Energy Total 93.40 90.92 2.48 2.7% Registration Number: 218-Po10142962C-000-000-0000000-0000 Registration Date/Time: 2018-10-09 09:02:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-09 08:46:36 CERTII TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE r -IOD Project Name: Chapman Residence Calculation Description: Title 24 Analysis Calculation DatelTime: 08:44, Tue, Oct 09, 2018 Input File Name: Chapman Res -Lot 212-Hideaway-Payton 18.ribd16x CF IRF-01 Page 2 of 14 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 50.0 48.9 0.0 48.9 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins • Non-standard duct location (any location other than attic) HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • - select distribution system type - • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • -- None -- Registration Number: 218-Po10142962C-000-000-0000000-0000 Registration Datef-Fime: 2018-10-09 09:02:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-09 08:46:36 CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE ! HOD Project Name: Chapman Residence Calculation Date/Time: 08:44, Tue, Oct 09, 2018 Calculation Description: Title 24 Analysis Input File Name: Chapman Res -Lot 212-Hideaway-Payton 18.ribdl6x CF 'RF-01. Page 3 of 14 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Chapman Residence 4900 1 5 5 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 2nd Floor Zone Conditioned HVAC-2nd Floorl 900 11.8 DHW Sys 1 n/a Master Bdrm Zone Conditioned HVAC-Master2 901 11.8 DHW Sys 1 n/a Great Room Conditioned HVAC-Living3 890 11.8 DHW Sys 1 n/a Bedl,Office,Casita Conditioned HVAC-Bedl,Office,Casita4 1239 11.8 DHW Sys 1 n/a Kitchen Conditioned HVAC-Kitchen5 970 11.8 DHW Sys 1 n/a CaICERTS,,, Inc.,. V F Registration Number: 218-Po1o142962C-000-000-0000000-0000 Registration Dateffime: 2018-10-09 09:02:30 HERS Provider: CalCERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-09 08:46:36 CERTIK TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE, HOD Project Name: Chapman Residence Calculation Date/Time: 08:44, Tue, Oct 09, 2018 Calculation Description: Title 24 Analysis Input File Name: Chapman Res -Lot 212-Hideaway-Payton 18.ribdl6x CF IRF-01 Page 4 of 14 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ftZ) Tilt (deg) NE Wall 2nd Floor Zone R-21 Wall 45 Front 324 10.8 90 SE Wall 2nd Floor Zone R-21 Wall 135 Left 624 60 90 SW Wall 2nd Floor Zone R-21 Wall 225 Back 264 86.4 90 NW Wall 2nd Floor Zone R-21 Wall 315 Right 192 54.4 90 Interior Surface 2nd Floor Zone»Master Bdrm Zone R-0 Interior Surface n/a n/a 693 0 n/a Roof 2 2nd Floor Zone R-38 Roof Attic W/ R-13 n/a n/a 900 n/a n/a Raised Floor 2nd Floor Zone R-19 Floor (F.19.2x8.16) n/a n/a 207 n/a n/a NE Wall 2 Master Bdrm Zone R-21 Wall 45 Front 100 27.3 90 SE Wall 2 Master Bdrm Zone R-21 Wall 135 Left 230 0 90 SW Wall 2 Master Bdrm Zone R-21 Wall 225 Back 200 148.1 90 NW Wall 2 Master Bdrm Zone R-21 Wall 315 Right 530 91.2 90 Interior Surface 2 Master Bdrm Zone»Great Room R-0 Interior Surface n/a n/a 793 0 n/a Roof 3 Master Bdrm Zone R-38 Roof Attic W/ R-13 n/a rva 901 n/a n/a NE Wall 3 Great Room R-21 Wall 45 Front 126 78 90 SW Wall 3 Great Room R-21 Wall 225 Back 378 203 90 Interior Surface 3 Great Room —Kitchen R-0 Interior Surface nla n/a 890 0 n/a SE Wall 3 Bedl,Office,Casita R-21 Wall 135 Left 440 131.2 90 SW Wall 4 Bed 1,Office, Casita R-21 Wall 225 Back 50 0 90 NW Wall 3 Bedl,Office,Casita R-21 Wall 315 Right 500 72.4 90 Interior Surface 4 Bedl,Office,Casita»2nd Floor Zone R-0 Interior Surface n!a n/a 793 0 n/a Roof 4 Bedl,Office,Casita R-38 Roof Attic W/ R-13 n/a n/a 1239 n/a n/a NE Wall 4 Kitchen R-21 Wall 45 Front 324 24 90 NE Wall 5 Kitchen R-21 Wall 45 Front 260 92.8 90 SE Wall 4 Kitchen R-21 Wall 135 Left 624 41.5 90 SW Wall 5 Kitchen R-21 Wall 225 Back 264 115.2 90 NW Wall 4 Kitchen R-21 Wall 315 Right 192 48 90 Interior Surface 5 Kitchen>> Bed 1,Office,Casita R-0 Interior Surface n/a n/a 793 0 n/a Roof 5 Kitchen R-38 Roof Attic W/ R-13 n/a n/a 352 n/a n/a Registration Number: 218-Po10142962C-000-000-0000000-0000 Registration Date/Time: 2018-10-09 09:02:30 HERS Provider: CalCERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-09 08:46:36 CERTI(I TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE' HOD Project ame: Chapman Residence C iculation Date/Time: 08:44, Tue, Oct 09, 2018 Calculation Description: Title 24 Analysis Input File Name: Chapman Res -Lot 212-Hideaway-Payton 18.ribdl6x CF 'RF-01 Page 5 of 14 OPAQUE SURFACES —Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 Name Zone Type Orientation Area (ft) Skylight Area (ft2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Roof Great Room R-38 Roof Cath W/ R-13 - specify - 890 0 3 0.1 0.85 No ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic 2nd Floor Zone Attic Roof2nd Floor Zone Unventilated 3 0.1 0.85 No No Attic Master Bdrm Zone Attic RoofMaster Bdrm Zone Unventilated 3 0.1 0.85 No No Attic Bedl,Office,Casita Attic RoofBedl,Office,Casita Unventilated 3 0.1 0.85 No No Attic Kitchen Attic RoofKitchen Unventilated 3 0.1 0.85 No No � CaICERTS, Inc. HERS PRiOVI DE R Registration Number: 218-Po10142962C-000-000-0000000-0000 Registration Date/Time: 2018-10-09 09:02:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-09 08:46:36 CERTI( TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE' 'iOD Project'Name: Chapman Residence Calculation Date/Time: 08:44, Tue, Oct 09, 2018 Calculation Description: Title 24 Analysis Input File Name: Chapman Res -Lot 212-Hideaway-Payton 18.ribd16x CF 1RF-01 Page 6 of 14 FENESTRATION I GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft) U-factor SHGC Exterior Shading W34 Window NE Wall (Front-45) - 1 3.6 0.22 0.25 Insect Screen (default) W35 Window NE Wall (Front-45) 1 3.6 0.22 0.25 Insect Screen (default) W36 Window NE Wall (Front-45) - -- 1 3.6 0.22 0.25 Insect Screen (default) W37 Window SE Wall (Left-135) - -- 1 3.6 0.22 0.25 Insect Screen (default) W38 Window SE Wall (Left-135) -- 1 3.6 0.22 0.25 Insect Screen (default) W39 Window SE Wall (Left-135) - -- 1 3.6 0.22 0.25 Insect Screen (default) W40 Window SE Wall (Left-135) - -- 1 3.6 0.22 0.25 Insect Screen (default) W41 Window SE Wall (Left-135) - 1 3.6 0.22 0.25 Insect Screen (default) W42 Window SE Wall (Left-135) - -- 1 3.6 0.22 0.25 Insect Screen (default) W43 Window SE Wall (Left-135) -- 1 3.6 0.22 0.25 Insect Screen (default) W44 Window SE Wall (Left-135) - 1 3.6 0.22 0.25 Insect Screen (default) W45 Window SE Wall (Left7135) - -- 1 3.6 0.22 0.25 Insect Screen (default) W46 Window SE Wall (Left-135) - -- 1 6.9 0.22 0.25 Insect Screen (default) W47 Window SE Wall (Left-135) - - 1 6.9 0.22 0.25 Insect Screen (default) W48 Window SE Wall (Left -135) -- 1 6.9 0.22 0.25 Insect Screen (default) W49 Window SE Wall (Left-135) - - 1 6.9 0.22 0.25 Insect Screen (default) d13 Window SW Wall (Back-225) - - 1 86.4 0.22 0.25 Insect Screen (default) W32 Window NW Wall (Right-315) - - 1 6.0 0.22 0.25 Insect Screen (default) d14 Window NW Wall (Right-315) - 1 42.4 0.22 0.25 1 Insect Screen (default) W33 Window NW Wall (Right-315) -- - 1 6.0 0.22 0.25 Insect Screen (default) W19 Window NE Wall 2 (Front-45) - - 1 18.6 0.22 0.25 Insect Screen (default) W52 Window NE Wall 2 (Front-45) - - 1 2.9 0.22 0.25 Insect Screen (default) W53 Window NE Wall 2 (Front-45) - - 1 2.9 0.22 0.25 Insect Screen (default) W54 Window NE Wall 2 (Front-45) - - 1 2.9 0.22 0.25 Insect Screen (default) d05 Window SW Wall 2 (Back-225) - 1 78.0 0.22 0.25 Insect Screen (default) W23 Window SW Wall 2 (Back-225) -- 1 61.4 0.22 0.25 Insect Screen (default) W60 Window SW Wall 2 (Back-225) - - 1 2.9 0.22 0.25 Insect Screen (default) W61 Window SW Wall 2 (Back-225) - - 1 2.9 0.22 0.25 Insect Screen (default) W62 Window SW Wall 2 (Back-225) - -- 1 2.9 0.22 0.25 Insect Screen (default) Registration Number: 218-Po10142962C-000-000-0000000-0000 Registration Date/Tme: 2018-10-09 09:02:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-09 08:46:36 CERTII TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEHOD Project Name: Chapman Residence Clculation DatelTime: 08:44, Tue, Oct 09, 2018 Calculation Description: Title 24 Analysis Input File Name: Chapman Res -Lot 212-Hideaway-Payton 18.ribd16x CF tRF-01 Page 7 of 14 W22 Window NW Wall 2 (Right-315) 1 56.4 0.22 0.25 Insect Screen (default) W21 Window NW Wall 2 (Right-315) 1 4.9 0.22 0.25 Insect Screen (default) W20 Window NW Wall 2 (Right-315) 1 4.9 0.22 0.25 Insect Screen (default) W18 Window NW Wall 2 (Right-315) -- 1 10.5 0.22 0.25 Insect Screen (default) W55 Window NW Wall 2 (Right-315) -- -- 1 2.9 0.22 1 0.25 Insect Screen (default) W56 Window NW Wall 2 (Right-315) - -- 1 2.9 0.22 0.25 Insect Screen (default) W57 Window NW Wall 2 (Right-315) - -- 1 2.9 0.22 0.25 Insect Screen (default) W58 Window NW Wall 2 (Right-315) - -- 1 2.9 0.22 0.25 Insect Screen (default) W59 1 Window NW Wall 2 (Right-315) - - 1 2.9 0.22 0.25 Insect Screen (default) d01 Window NE Wall 3 (Front-45) ---- -- 1 78.0 0.22 0.25 Insect Screen (default) d06 Window SW Wall 3 (Back-225) 20.3 10.0 1 203.0 0.22 0.25 Insect Screen (default) d03 Window SE Wall 3 (Left-135) - -- 1 21.6 0.22 0.25 Insect Screen (default) W28 Window SE Wall 3 (Left-135) 1 5.8 0.22 0.25 Insect Screen (default) W29 Window SE Wall 3 (Left-135) - 1 5.8 0.22 0.25 Insect Screen (default) W30 Window SE Wall 3 (Left-135) - 1 5.8 0.22 0.25 Insect Screen (default) W31 Window SE Wall 3 (Left-135) " - 1 5.8 0.22 0.25 Insect Screen (default) d02 Window SE Wall 3 (Left-135) - 1 86.4 0.22 0.25 Insect Screen (default) W15 Window NW Wall 3 (Right-315) -- - 1 7.0 0.22 0.25 Insect Screen (default) W13 Window NW Wall 3 (Right-315) - - 1 9.0 0.22 0.25 Insect Screen (default) W12 Window NW Wall 3 (Right-315) - - 1 13.2 0.22 0.25 Insect Screen (default) W11 Window NW Wall 3 (Right-315) - - 1 13.2 0.22 0.25 Insect Screen (default) W16 Window NW Wall 3 (Right-315) - - 1 15.0 0.22 0.25 Insect Screen (default) W17 Window NW Wall 3 (Right-315) - - 1 15.0 0.22 0.25 Insect Screen (default) W01 Window NE Wall 5 (Front-45) - 1 16.2 0.22 0.25 Insect Screen (default) W02 Window NE Wall 5 (Front-45) 1 3.2 0.22 0.25 Insect Screen (default) W03 Window NE Wall 5 (Front-45) 1 16.2 0.22 0.25 Insect Screen (default) W04 Window NE Wall 5 (Front-45) - 1 3.2 0.22 0.25 Insect Screen (default) W05 Window NE Wall 5 (Front-45) - - 1 13.2 0.22 0.25 Insect Screen (default) W06 Window NE Wall 5 (Front-45) - - 1 4.8 0.22 0.25 Insect Screen (default) W07 Window NE Wall 5 (Front-45) 1 13.2 0.22 0.25 Insect Screen (default) W08 Window NE Wall 5 (Front-45) 1 4.8 0.22 0.25 Insect Screen (default) W09 Window NE Wall 5 (Front-45) -- 1 13.2 0.22 0.25 Insect Screen (default) W10 Window NE Wall 5 (Front-45) - 1 4.8 0.22 0.25 Insect Screen (default) Registration Number: 218-P010142962C-000-000-0000000-0000 Registration Dateffime: 2018-10-09 09:02:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-09 08:46:36 CERTI� TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE' 'IOD ProjectName: Chapman Residence Ca culation Date/Time: 08:44, Tue, Oct 09, 2018 Calculation Description: Title 24 Analysis Input File Name: Chapman Res -Lot 212-Hideaway-Payton 18.ribd16x CF 'RF-01 Page 8 of 14 W25 Window SE Wall 4 (Left-135) 1 21.5 0.22 0.25 Insect Screen (default) W24 Window SE Wall 4 (Left-135) — — 1 20.0 0.22 0.25 Insect Screen (default) d08 Window SW Wall 5 (Back-225) - 1 115.2 0.22 0.25 Insect Screen (default) d07 Window NW Wall 4 (Right-315) 6.0 8.0 1 48.0 0.22 0.25 Insect Screen (default) OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft) U-factor D34 NE Wall 4 24.0 0.50 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 1 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up d06 8 0.1 8 8 0 0 0 0 0 1 0 0 0 0 d07 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Ak.. a i tm., r. m i zo , i n L--,-,w * HERS ('ROVIDFR Registration Number: 218-Po10142962C-000-000-0000000-0000 Registration Dateffime: 2018-10-09 09:02:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-09 08:46:36 CERTII TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE' iOD ProjectRame: Chapman Residence Calculation Date/Time: 08:44, Tue, Oct 09, 2018 Calculation Description: Title 24 Analysis Input File Name: Chapman Res -Lot 212-Hideaway-Payton 18.ribd16x CF �RF-01 Page 9 of 14 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof2nd Floor Zone Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic W/ R-13 attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco • Floor Surface: Carpeted Floors Over Floor Deck. Wood Siding/sheathing/decking R-19 Floor (F. 1 9.2x8.16) Crawlspace Wood Framed Floor 2x8 @ 16 in. O.C. R 19 0.047 Cavity/Frame: R-19 /2x8 • Inside Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 R-0 Interior Surface Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.277 Other Side Finish: Gypsum Board • Around Roof Joists: R-0.0 insul. - • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofMaster Bdrm Zone Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Sheathing/Insulation: R13 Sheathing • Cavity/Frame: R-38/2x12 • Roof Deck: Wood Siding/sheathing/decking R-38 Roof Cath W/ R-13 Cathedral Ceilings Wood Framed Ceiling 2x12 @ 16 in. O.C. R 38 0.021 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofBedl,Office,Casita Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing. Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofKitchen Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) Registration Number: 218-P010142962C-000-000-0000000-0000 Registration Date/Time: 2018-10-09 09:02:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-09 08:46:36 CERTII TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE ! HOD Project Flame: Chapman Residence Calculation Date/Time: 08:44, Tue, Oct 09, 2018 Calculation Description: Title 24 Analysis Input File Name: Chapman Res -Lot 212-Hideaway-Payton 18.ribdl6x CF ?RF-01 Page 'f 0 of 14 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade Master Bdr n Zone 901 74 None 0.8 No Slab -on -Grade 2 Great Room 890 160 None 0.8 No Slab -on -Grade 3 Bed 1,Office, Casita 1239 160 None 0.8 No Slab -on -Grade 4 Kitchen 970 160 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard `DHW Heater 1 (1) 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Input Rating / Tank Standby Heater Tank Uniform Energy Pilot / Insulation Loss / First Hour NEEA Heat Pump Tank Location Element Number Volume Factor / Energy Thermal R-value Recovery Rating I Brand / Model I or Ambient Name Type Tank Type of Units (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Other Condition DHW Heater 1 Gas Large Storage 1 100 0.86 TE 77,000 Btu/hr R-0/R-0 0.0085 n/a n/a n/a Registration Number: 218-P010142962C-000-000-0000000-0000 Registration DateMme: 2018-10-09 09:02:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-09 08:46:36 CERTIf TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE r 10D Project game: Chapman Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 08:44, Tue, Oct 09, 2018 Input File Name: Chapman Res -Lot 212-Hideaway-Payton 18.ribdl6x CF IRF-01 Page 11 of 14 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC-2nd Floorl Other Heating and Cooling Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 System HVAC-Master2 Other Heating and Cooling Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 System HVAC-Living3 Other Heating and Cooling Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 System HVAC-Bedl Other Heating and Cooling Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution System 4 ,Office,Casita4 System HVAC-Kitchen5 Other Heating and Cooling Heating Component 5 Cooling Component 5 HVAC Fan 5 Air Distribution System 5 System HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFumace 1 80 AFUE Heating Component 2 CntrlFumace 1 80 AFUE Heating Component 3 CntrlFumace 1 80 AFUE Heating Component 4 CntrlFumace 1 80 AFUE Heating Component 5 CntriFumace 1 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Efficiency Name System Type Number of Units EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 12.7 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 1 12.7 16 Not Zonal Single Speed Cooling Component 2-hers-cool Cooling Component 3 SplitAirCond 1 12.7 16 Not Zonal Single Speed Cooling Component 3-hers-cool Cooling Component 4 SplitAirCond 1 12.7 16 Not Zonal Single Speed Cooling Component 4-hers-cool Cooling Component 5 SplitAirCond 1 12.7 16 Not Zonal Single Speed Cooling Component 5-hers-cool Registration Number: 218-P010142962C-000-000-0000000-0000 Registration Date/Tme: 2018-10-09 09:02:30 HERS Provider: CalCERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-09 08:46:36 CERTI! TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE r 1101) Project Warne: Chapman Residence CTculation Date/Time: 08:44, Tue, Oct 09, 2018 Calculation Description: Title 24 Analysis Input File Name: Chapman Res -Lot 212-Hideaway-Payton 18.ribd16x CF IRF-01 Page 12 of 14 HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required Cooling Component 2-hers-cool Required 350 Required Required Required Cooling Component 3-hers-cool Required 350 Required Required Required Cooling Component 4-hers-cool Required 350 Required Required Required Cooling Component 5-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Specified Lower Leakage 8 Attic None Air Distribution System 1-hers-dist Target Air Distribution System 2 DuctsAttic Specified Lower Leakage 8 Attic None Air Distribution System Target, 2-hers-dist Air Distribution System 3 DuctsOutdoor Specified Lower Leakage Target 8 auls�de None Air Distribution System 3-hers-dist Air Distribution System 4 DuctsAttic Specified Lower Leakage 8 Attic None Air Distribution System Target 4-hers-dist Air Distribution System 5 DuctslnAll Specified Lower Leakage 8 Conditioned zoneT None Air Distribution System 5-hers-dist Target HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 2-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 3-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 4-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 5-hers-dist Required 5.0 Required Not Required Not Required Not Required Required Registration Number: 218-Po10142962C-000-000-0000000-0000 Registration DatefFime: 2018-10-09 09:02:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-09 08:46:36 CERTI( TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I 10D Project Tame: Chapman Residence Calculation Date/Time: 08:44, Tue, Oct 09, 2018 Calculation Description: Title 24 Analysis Input File Name: Chapman Res -Lot 212-Hideaway-Payton 18.ribdl6x CF' )RF-01 Page 13 of 14 HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.52 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.52 HVAC Fan 2-hers-fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.52 HVAC Fan 3-hers-fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.52 HVAC Fan 4-hers-fan HVAC Fan 5 Single Speed PSC Furnace Fan 0.52 HVAC Fan 5-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.52 HVAC Fan 2-hers-fan Required 0.52 HVAC Fan 3-hers-fan Required 0.52 HVAC Fan 4-hers-fan Required 0.52 HVAC Fan 5-hers-fan Required 0.52 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 94 0.25 Default 0 Required Registration Number: 218-Po10142962C-000-000-0000000-0000 Registration Date/Tme: 2018-10-09 09:02:30 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-09 08:46:36 CERTI! TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE, HOD Project 13ame: Chapman Residence Calculation Date/Time: 08:44, Tue, Oct 09, 2018 Calculation Description: Title 24 Analysis Input File Name: Chapman Res -Lot 212-Hideaway-Payton 18.ribd16x CF iRF-01 Page 14 of 14 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2018-10-09 09:02:30 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Tim Scottt Company: Date Signed: Scott Design and Title 24, Inc. 2018-10-09 09:02:30 Address: License: 77085 Michigan Drive N/A City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 218-Po10142962C-000-000-0000000-0000 Registration Date/Time: 2018-10-09 09-02:30 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Easy to Verify at CaICERTS.com HERS Provider: CaICERTS inc. Report Generated at: 2018-10-09 08:46:36 Sladden Engineering 45090 Golf Center Parkway, Suite F, Indio, CA 922M (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite C, Buena Park CA 90621(714) 523-0952 Fax (714) 523-I369 450 Egan Avenue, Beaumont, CA 92223 (951) 7743 Fax (951) 8454863 800 E. Florida Avenue, Hemet, CA 92543 (951 66 Fax (951} 766�778 �p June 21, 2018 d�Y 1� Project No. 544-18207 18-06-306 Mr. Brock J. Paytonj��`�_ 4490 Jasmine Avenue` 4ON Culver City, California 90232 �G(Q Project: Proposed Custom Resid ��.C/ ��+' 22 2018 80-129 Via Pessaro The Hideaway - Lot 212 OF LA QUINTA La Quinta, California AND DEVELOPMENT DEPARTMENT Subject: Geotechnical Update Ref: Geotechnical Engineering Report prepared by Earth Systems Southwest (ESSW) dated September 22, 2000; File No. 07117-10, Report No. 00-09-772 Report of Testing and Observation During Rough Grading prepared by ESS dated August 28, 2002; File No. 07117-11, Report No. 01-07-718 Report of Testing and Observation During Rough Grading prepared by Sladden Engineering dated October 12, 2003, Project No. 544-2199 Report No. 03-10-647 In accordance with your request, we have reviewed the above referenced geotechnical reports as they relate to the design and construction of the proposed custom residence. The project site is located at 80-129 Via Pessaro within the Hideaway Golf Club development in the City of La Quinta, California. It is our understanding that the proposed residence will be a relatively lightweight wood -frame structure supported by conventional shallow spread footings and concrete slabs on grade. The subject lot was previously graded during the rough grading of the Hideaway project site and was subsequently regraded. The rough grading included over -excavation of the native surface soil along with the placement of engineered fill soil to construct the building pads. The regrading included processing the surface soil along with minor cuts and fills to construct the individual building pads to the current configurations. Some additional over -excavation was performed in areas where the building envelopes were reconfigured. The supplemental site grading is summarized in the referenced Report of Testing and Observations During Rough Grading prepared by Sladden Engineering along with the compaction test results. The referenced reports include recommendations pertaining to the construction of residential structure foundations. Based upon our review of the referenced reports, it is our opinion that the structural values included in the referenced grading report prepared by Sladden Engineering remain applicable for the design and construction of the proposed residential structure foundations. Sladden Engineering www.Sladde►terrjZftreerin.. coat Elp June 21, 2018 -2- Project No_ 544-18207 i 8-06-3 06 Because the lot has been previously rough graded, the remedial grading required at this time should be minimal provided that the building falls within the previously established building envelope. The building area should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted to a minimum of 90 percent relative compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. The allowable bearing pressures recommended in the referenced grading report prepared by Sladden Engineering remain applicable. Conventional shallow spread footings should be bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be utilized if desired. The maximum allowable bearing pressure should be 3000 psf. The recommended allowable bearing pressures may be increased by one-third for wind and seismic loading. Lateral forces may be resisted by friction along the base of the foundations and passive resistance along the sides of the footings. A friction coefficient of 050 times the normal dead load forces is recommended for use in design. Passive resistance may be estimated using an equivalent fluid weight of 300 pcf. If used in combination with the passive resistance, the frictional resistance should be reduced by one third to 0.33 times the normal dead load forces. The bearing soil is non -expansive and falls within the "very low" expansion category in accordance with 2016 California Building Code (CBC) classification criteria. Slab thickness and reinforcement should be determined by the structural engineer. We recommend a minimum floor slab thickness of 4.0 inches. All slab reinforcement should be supported on concrete chairs to ensure that reinforcement is placed at slab mid -height. Slabs with moisture sensitive surfaces should be underlain with a moisture vapor retarder consisting of a polyvinyl chloride membrane such as 10-mil Visqueen, or equivalent. All laps within the membrane should be sealed and at least 2 inches of clean sand should be placed over the membrane to promote uniform curing of the concrete. To reduce the potential for punctures, the membrane should be placed on a pad surface that has been graded smooth without any sharp protrusions. If a smooth surface can not be achieved by grading, consideration should be given to placing a 1-inch thick leveling course of sand across the pad surface prior to placement of the membrane. Sladden Engineering www.Sladdenenefneerins. cvm June 21, 2018 -3- Project No. 544-18207 18-06-306 The seismic design category for a structure may be determined in accordance with Section 1613 of the 2016 CBC or ASCE7. According to the 2016 CBC, Site Class D may be used to estimate design seismic loading for the proposed structures. The 2016 CBC Seismic Design Parameters are summarized below. Risk Category (Table 1.5-1): I/I= Site Class (Table 1613.3.2): D Ss (Figure 1613.3.1): 1.500g Sl (Figure 1613.3.1): 0.654g Fa (Table 1613.3.3(1)):1.0 Fv (Table 1613.5.3(2)): 1.5 Sms (Equation 16-37 (Fa X Ss)):1.500g Smi (Equation 16-38 (Fv X Si)): 0.982g SDS (Equation 16-39 12/3 X Sms)):1.000g SD1(Equation 16-40 12/3 X Smx]): 0.654g Seismic Design Category: D If you have questions regarding this letter or the referenced reports, please contact the undersigned. Respectfully submitted, SLADDEN EitiNGINEERII Brett L. Anderso Principal Engineer SER/gvm Copies: 4 / Addressee "RETIL. y ANDryETRC50N ,i 'Uir5 No. 2A Exp. 9/30;18 CNIL ENGINEERINr` cf' r *XEofi Sladden .Engbieering www.Sladdenenelneerine, con: yc � -M-zo -7 Please verify that soils reports contain all of the above information. In addition, to assure continuity between the InvestigationlreporUng stage and the execution stage, please use the folloyving checklist to verify that the conclusions and recommendations in the report cover all the required elements. Only then can we be assured that the construction documents address ail of the site soil conditions. La Quinta Geotechnicall Report Checklist Does the `Conclusions and Recommendations" section of the report address each of the following criteria? "Address" means: _ (a) the criterion is considered significant and mitigation measures) noted, on (b) the criterion is considered insignificant and explicitly so stated. 'des -NO Crlterlon 0 Foundation criteria based upon bearing capacity of natural or compacted soil. © Foundation criteria to mitigate the effects of expansive soils. Cf Foundation criteria based upon bearing capacity. of natural or compacted soil - El Foundation criteria to mitigate.the effects of liquefaction. ® Foundation criteria to mitigate the effects of seismically induced differential settlement. 0 ® Foundation criteria to mitigate the effects of long-term differential settlement I ® Foundation criteria to mitigate the effects of varying soil strength. © Foundation criteria to mitigate expected total and differential settlement. Any "No" answers to the above checklist should be noted as specific required corrections. • CA- R ETT L. NaERsoN NO. C453;9 CIVIL :NGINEEI11NG �Op rAf Construction Debris Management Plan Summary of Requirements As of January 1, 2017, The Green Building Standards Code (CALGreen) requires that the construction of most new structures in the State of California comply with sections 4.408 and 5.408 of the code in accordance with Assembly Bill 939 requiring that no more than 35% of jobsite waste be disposed of as trash at local land fill sites and transfer stations. Exceptions may be made for certain projects under certain conditions. The City of La Quinta is committed to the highest level of environmental respect, to conserving our precious natural resources and setting an example to provide for a better world for generations to come. Recycling helps keep reusable resources out of landfills and will also reduce disposal costs. IMPORTANT: Burrtec Waste & Recycling Services is the City's franchise hauler. If you choose to self -haul any recyclables or trash, you must provide copies of all weight tickets and/or receipts from the transfer station, landfill, or recycler as the job progresses. Clean-up companies and other haulers are not permitted to haul waste or recyclables from the City of La Quinta. Self -haul weight tickets should be submitted to: Renado Gouldlock, District Environmental Coordinator - rgouldlock@burrtecdesert.com, or faxed to (760) 340-0417, or mailed to: 41575 Eclectic Street, Palm Desert, CA. 92260. 69FS Zo 18'_oZO CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 9/25/2009 Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date: (P 1 1 JL03 Developer: Tract No.: a9�g4'Z Tract Name: � �� Lot No.(s): ;21 Z Address(s):50 — ZQ ,e��aci r� Phone Number: The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the Building & Safety Department: K CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4, #5 & #7 BELOW ❑ TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW ❑ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1, #2, #3, #5 & #7 BELOW ❑ WALLS, SIGNS, OTHER: PROVIDE ITEM #6 BELOW 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation Certificate can be provided. 2. Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils Engineer. Recently rough graded residential developments which have a previously approved geotechnical certification are exempt from this requirement. 3. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots. 4. Complete the attached <1 acre per lot or inf ill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM 10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 certification number is required. 5. Attach a copy of the rough or precise grading plan to the Public Works Department showing building location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain development plan. 6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. 7. Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW approved building construction projects require either a WQMP or a completed WQMP exemption form. o Approved maps/plans may be viewed at the following link: hitp://www.la-guinta.org/PlanCheck/m search.aspx I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff. Recommended by: /� Date: Public Works Distribution: ( ) Green Sheet to Building & Safet, (� ) Green Sheet to Planning Departr Declined for approval for reason(s) as follow(s), please correct and resul TAChecklists - Forms & Applications\Forms & Applications\GREEN SHEET -cover & PM10 less than 1 Acre Revised 10-02-12.doc City of La Quinta - PM 10 Fugitive Dust Control Project Information Construction Phase PM10 Agreement (< 1 acre/lot or Infill Project) Project Information Project Contractor:(G Project Phase Project Name: (check one) �(� !1 Project Tract/Lot Numbers: 2 _ -{ `T if Construction ❑ Demolition , 1 Project Street Address: id - iZQ V i Total Acres in Active Construction (< 1 acre per r Anticipated Start Date:/:J / Anticipated Completion Date: 7 Lot): PM10 Contact Information Please note: Dust control is required 24 hours a day, 7 days a week, regardless of construction status. Person listed below is responsible for dust control during business and non -business hours. Name: M uz,�Nae.A t--9-Pa Title:f�l�' Company Name: A n� c"g. ` Mailing Address: J 40 X V F} Ti(;� 2 L_ C,&- 9 7iZ J City, State, ZIP Code: Primary Phone #: Fax #: 24 Hour Emergency Phone#: � z_S - 2-9-6�j 9-6 4-0 b Cell Phone #: Email Address: I �� i✓ 0I ' L PM 10 Certificate #: C `% 19 C2— 50 5 t121 2Z (o The above stated property owner for authorized representative): ❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; ❖ Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. ❖ Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; ❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary,; ❖ Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes; ❖ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control plan or a ty1Co y i iti atement activities. Signature of Property ❑wner r A thorized Representative Date City of La Quinta - PM 10 Fugitive Dust Control Plan (< 1 acre per Lot or Infill Project) This Fugitive Dust Control Plan shall take into account applicable SCAQMD Regulations Rule 403, 403.1, 401, 402, 201, 203 and Portable Equipment Registration Program (PERP). ❖ WATERING: Continuous watering is required to prevent dust and must occur a minimum of four (4) times daily. Water shall be applied from an adequate sized metered water source to dry soils to prevent: ■ Visible dust emissions > 20% opacity • Visible dust emissions that travel > 100 feet from the source (within site) 11 Visible dust emissions that cross any property line ❖ EDUCATION: The responsible dust control Individual and key personnel shall attend SCAQMD PM10 class and obtain PM10 certificate number prior to construction activity (training information may be obtained by contacting SCAQMD at (909) 396-2183). ❖ CONSTRUCTION & DEMOLITION ACTIVITIES: A copy of this approved Fugitive Dust Plan must be kept on site. At least one short-term stabilization method must be used during off hours. At least one long-term stabilization measure must be used within ten (10) days of ceasing activity. ❖ WEATHER MONITORING: Wind predictions shall be monitored. ❖ SIGNAGE: Approved signs shall be installed at a highly visible location. Please refer to the Coachella Valley Fugitive Dust Control Plan Handbook for Construction Signage Guidelines. ❖ TRAFFIC: Construction traffic shall not be allowed on the pad, unless absolutely necessary. If vehicles operate on pad, pad shall be kept firm and moist through hose watering and sprinklers; and a maximum traffic speed of 15mph will be enforced. Fugitive Dust shall be prevented by fencing off site to prevent unauthorized traffic on pad. ❖ PARKING: Parking is not allowed on pad. All vehicles must park on street at designated areas only. ❖ TRACK OUT: Provide 24 hour street cleaning and track out system as approved by City Public Works inspectors. No dirt on public or private roads. Track out shall be cleaned up within one (1) hour of incident and- at the conclusion of each workday. ❖ DIRT PILES: Dirt piles shall be limited to 50 cubic yards and built per California Building Code grading requirements. Piles shall be kept moist or covered with tarp material. Larger dirt piles will require stockpile or grading permit. ❖ FENCING: Provide PM10 fencing at perimeter of public roads and where applicable. Wood slat fencing can be installed at rear of property and return 20 feet on either side if HOA restrictions apply. Block walls can replace PM10 fencing during the construction phase.C. ❖ EQUIPMENT: Extra hoses and sprinklers shall be maintained on site. ❖ EXCAVATION MEASURES: All areas to be excavated or graded shall be pre -watered. Water shall also be applied during excavation or grading operations. ❖ DUMP TRUCKS: Open top dump trucks.1shaII:b6 wet down, moist and covered with a tarp prior to leaving site. ❖ INACTIVE SITE: Within 10 days of ceasing of activities, re -vegetate or permanently stabilize as required. ❖ RECORD KEEPING" `Fugitive DUs't•-Control -Plan records (i.e. self inspection records, records of use of chemical suppressants, etc.) shall be maintained, for 3 years by the Property Owner (or Authorized Representative). Property Owner 'shall ' notify the —City and SCAQMD within 10 days of completion of project. Water Quality Manaaement Plan (WQMP) Exemption Form - Whitewater River Reqion Documentation of Project Not Requiring a WQMP but Requiring Site Design BMPs and Source Control BMPs by Entitlement Conditions of Approval or Permit Conditions - WQMP Required for the Listed Change of Land Uses or for Changes of Pollutant Stream (All Questions Below Must be Answered "No" To Exempt Project) Entitlement or construction of new single-family hillside residence(s) that create 10,000 square feet, or more, of impervious area where the pre -development natural slope is 25% or greater? i Yes No 1 Entitlement or construction of new single-family hillside residence(s) that create 10,000 square feet, or more, of impervious area where the pre -development natural slope is 10% or greater where erosive soil conditions are known? Entitlement or construction of new commercial and industrial development(s) of 100,000 square feet or more? Entitlement or construction of new automotive repair shop(s) including body, upholstery, paint, exhaust, tire, transmission, engine or other automotive specialty repair. [Standard Industrial Classification (SIC) codes 5013, 7532, 7533, 7534, 7537, 7538, and 75391? Entitlement or construction of new retail gasoline outlet(s) disturbing greater than 5,000 square feet? / Entitlement or construction of new restaurant(s) (or potential restaurant shell space) disturbing greater than 5,000 square feet? Entitlement or construction of new home subdivision(s) with 10 or more housing units? Entitlement or construction of new parking lot(s) of 5,000 square feet or more, or with 25 or more parking spaces, and potentially exposed to Urban Runoff? / / Applicant Information Name and Title `& Company A*-'-L Phone S Email Project Information Project Name Type (SFH, Multi -Family, Commercial, Etc.) - Location or Street Address aQe�SO� Nearest Cross Streets ( 1A-� &4� Municipality/County/Zip Code La Quinta Of Tract Number(s) and/or Assessor Parcel Number(s) '1 -1-7 Other Location Information Watershed Whitewater River Source Control BMP Information Size of Project Area (nearest 0.1 acre) Q 3 aGY e Project Area managed with Site Design or Low Impact Development (LID) BMPs (nearest 0.1 acre) Is the project subject to onsite retention by City ordinance or policy? lo , �-� t Name of the Entity that will implement, operate, and maintain the Source Control BMPs j�/� I � i(fL A-G-t_ �ZI �jf, A Cvfi'Sf- Contact Name Street or Mailing Address 53 40 ( �r City 1-0 Zip Code Check Item To be Performed Source Control BMP Requirements - All Projects Require Non -Structural BMP Source Control Non -Structural BMP (See Appendix H, Section 4.5.2.1) Ongoing Irrigation System and Landscape Maintenance Ongoing Litter Control Ongoing Drainage System Inspection & Maintenance Education/Training for Property Owner, Operators, Occupants, or Employees / Activity Restrictions — Prohibition of Debris Blowing/Sweeping/Washing into Street/Storm Drain, Closed Trash Lids, Restriction of Vehicle Washing / Ongoing Street Sweeping at Private Streets and Private Parking Lots Check Item To be Provided Source Control BMP Requirements — Small Sloped Lots, Small Commercial, < 10 Unit Subdivisions, < 5,000 Square Ft. Parking Lots, Etc. Structural BMP (See Appendix H, Section 4.5.2.2) Storm Drain Inlet Stenciling and Signage Landscape and Irrigation System Design to Minimize Erosion & Nuisance Runoff Protection of Slopes and Channels to Minimize Erosion Multi -Family Project Use of Community Car Wash Racks Wash Water Controls for Food Preparation Areas to Use Sanitary Sewer Fueling Area (Design & Maintenance) Including PCC Surface, Canopy & Spill Prevention Air/Water Supply Area Drainage (Design & Maintenance) Including Spill Area Containment Trash Storage Areas (Design & Maintenance) Including Attached Lids, Storm Water Controls Loading Docks (Design & Maintenance) Including Storm Water Controls, Dry & Frequent Cleaning Procedures Maintenance Bays (Design & Maintenance) Including Indoor Location & Storm Water Containment Vehicle and Equipment Wash Areas (Design & Maintenance) Including Canopy & Containment Outdoor Material Storage Areas (Design & Maintenance) Including Canopy & Containment Outdoor Work Areas or Processing Areas (Design & Maintenance) Including Canopy & Containment CC&R's, Maintenance Agreements or Other mechanisms will be used to ensure the ongoing operation, maintenance, funding, transfer and implementation of the project -specific WQMP requirements. Legal description and plat stamped by Registered Surveyor to be attached to the applicable CC&R or Maintenance Agreement for recordation at Riverside County. (Optional Requirement to be reviewed on a Project by Project basis) BMP Acknowledgement The applicant shall comply with listed BMPs and applicable provisions of the City's NPDES stormwater discharge permit, LQMC Sections 8.70.010 et seq. (Stormwater Management and Discharge Controls), and 13.24.170 (Clean Air/Clean Water); Riverside County Ordinance No. 457; the California Regional Water Quality Control Board — Colorado River Basin Region Board Order No. 137-2008-0001 and the State Water Resources Control Board's Order No. 99-08-DWQ. Signature: jr Print Name: Title: Date: �P/ 6 / Phone: �] Applicant Certification I certify that I have read this form in its entirety and understand the City's submittal and review process and the requirements for this form. I understand and agree that if during the processing of the form, it is determined the information contains errors or omissions, clarification and/or supplemental information may be required and the preparation of such information may be considered, in the Community Development Director's judgment, an unreasonable delay and will result in a suspension of processing time limits in accordance with the California Code of Regulations, Title 14, Section 15109. Signature: Print Name: Title: )?:;? Date: &I � l Phone:J) Owner Certification I certify under the penalty of the laws of the State of California that I am the property owner of the property that is the subject matter of this application and I am authorizing and hereby do consent to the filling of this application and acknowledge that the final approval by the City of La Quinta, if any, may result in restriction, limitations and construction obligations being imposed on this real property. Print Name: Title: Date: -6—I41 Phone: (6 6) v'C b