BMCH2018-037578-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type/Subtype:
MECHANICAL/
Application Number:
BMCH2O18-0375
Property Address:
54625 AVENIDA DIAZ
APN:
774263017
c&ht 4 �P 0"Aro
DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Description: RICE RESIDENCE / HVAC CHANGE OUT
Property Zoning:
Application Valuation: $8,500.00
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Owner:
WAYNE RICE
54625 AVENIDA DIAZ
LA QU I NTA, CA 92253
Date: 9/6/2018
Applicant: ""'' Contractor:
IE INC a VOTTA ENTERPRISES INC DBA COMFORT AIR
31225 LA BAYA 72248 NORTHSHORE ST STE 101
WESTLAKE VILLAGE, CA 91362 THOUSAND PALMS, CA 92276
S C rCp 12
2018 (760)320-5800
Llc. No.: 763937
CITY OF LA 01AITA
--------------------------------------------___-----------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C20 License No.: 763937
Date: q ( 7 Contractar
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_),I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
ofMork for which this permit is issued.
�--- I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD503453902
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
Workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: (Z 11 a Applicant:�}.R�
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above -mentioned property for inspection purposes.
Date: 4 (� ($ Signature (Applicant or Agent): ->�-�ez__
Application Number:
BMCH2018-0375
Property Address:
54625 AVENIDA DIAZ
APN:
774263017
Application Description:
RICE RESIDENCE / HVAC CHANGE OUT
Property Zoning:
Application Valuation:
$8,500.00
Applicant:
IE INC
31225 LA BAYA
WESTLAKE VILLAGE, CA 91362
Date: 9/6/2018
Owner:
WAYNE RICE
54625 AVENIDA DIAZ
LA QUINTA, CA 92253
Contractor:
VOTTA ENTERPRISES INC DBA COMFORT AIR
72248 NORTHSHORE ST STE 101
THOUSAND PALMS, CA 92276
(760)320-5800
Llc. No.: 763937
Detail: HVAC CHANGE OUT -14 S€ER/80 AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. PER 2016
CALIFORNIA BUILDING CODES.
DESCRIPTION
FINANCIAL
ACCOUNT
CITY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA:
$1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM
101-0000-42402
0
$39.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM PC
101-0000-42600
0
$78.02
Total Paid for CHANGEOUT: $117.O3
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PERMIT ISSUANCE
101-0000-42404
0
$98.83
Total Paid for PERMIT ISSUANCE: $98.83
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION ACCOUNT CITY AMOUNT
TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
ta Qw�frcv
-- GEM of,lr,c DESEM' — —
PERMIT #
PLAN LOCATION:
Project Address: 54625 Avenida Diaz
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #:
Replace 5 ton / 90,000 BTU com fete HVAC s stem
Applicant Name: Steven Schnierer
Address: 31225 La Ba a Drive Suite 213
City, ST, Zip: Westlake Village, CA 91362
Telephone: 818-735-7876
Email: swschnierer@roadrunner.com
Valuation of Project $ 8,500.00
Contractor Name: Comfort Air
New SFD Construction:
Address: 72248 Northshore Street Suite 101
Conditioned Space SF
City, St, Zip Thousand Palms, CA 92276
Garage SF
Telephone: 760-320-5800
Patio/Porch SF
Email:
Fire Sprinklers SF
State Lic: 763937 City Bus Lic:
Arch/Eng Name:
Construction Type: Occupancy:
Address:
Grading:
City, St, Zip
Telephone:
j
Bedrooms: Stories: # Units:
Email:
State Lic: City Bus Lic:
Property Owner's Name: Wayne Rice
New Commercial / Tenant Improvements:
Address: 54625 Avenida Diaz
Total Building SF
City, ST, Zip La Quinta, CA 92253
Construction Type: Occupancy:
Telephone: 760-564-2660
Email:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
CERTIFICATE OF COMPLIANCE CFIR-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 1 of 3)
Project Name: WAYNE RICE Date Prepared: 2018-09-04
A. General Information
CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF1R-ALT-02 document for each dwelling unit.
O3
Project Name
WAYNE RICE
02
Date Prepared
2018-09-04
03
Project Location
54625 AVENIDA DIAZ
04
Building Type
Single family
05
CA City
La Quinta
06
Dwelling Unit Name
WAYNE RICE
07
Zip Code
92253
08
Dwelling Unit Conditioned
1925
Floor Area (ft)
Number of Space
09
Climate Zone
15
10
Conditioning (SC) Systems in
1
this Dwelling Unit:
B. Space Conditioning (SC) System Information
01
02
03
04
05
06
07
08
09
10
Is the SC
Installing a
SC System
SC System
CFA served
system a
refrigerant
Installing new SC
Installing
Installing
Installing
Identification or
Location or Area
by this SC
ducted
containing
system
more than 40
entirely new
entirely new
Name
Served
System (ft)
system?
component?
components?
feet of ducts?
duct system?
SC system?
Alteration Type
SYSTEM 1
LOCATION 1
1925
Yes
Yes
Yes
No
No
No
Altered space
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section 15O.2(b)1Diib)
This section does not apply to this project.
Registration Number: 418-A020067892A-000-000-0000000-0000 Registration Date/Time: 2018-09-04 20:37:07 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2018-09-04 20:37:06
Schema Version: rev 10/16
CERTIFICATE OF COMPLIANCE
CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC)
(Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)3E and F)
01
02
03
04
0S
06
07
08
09
10
11
12
Heating
Cooling
System
Heating
Altered
Heating
Minimum
Altered
Cooling
Minimum
Required
New or
Identification
System
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct
or Name
Type
Components
Type
Value
System Type
Components
Type
Value
Type
Duct Length
R-Value
Centralrg as
All new
Central split
All new
This field or
This field or
SYSTEM 1
fu nace
heating
AFUE
0.81
cooling
SEER
14
Setback
section is not
section is not
components
components
applicable
applicable
Reaukred Ducumontation:
CF2R-MCH-01-E - Space Conditioning Systems
- Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (C2 1-10, 12 and 13) and R8 (CZ 11 and 14-16)
CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed Irk ducted systems, or when more than 40 ft of duct length is replaced
-Leakage rate compliance: - 15% or- 10% leakage to outside, or seal all accessible leaks.
CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are Installed or altered (applicable in CZ 2, 8-15L
CF2R and CF3R-MCH-23 Airflow Rate>= 300 CFM per ton required when MCH-25 is required.
LutpilDnil
- Duct systems registered with HERS provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements.
- Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MCH-25.
-Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements.
E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)1E, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C)
This section does not apply to this project.
Registration Number: 418-A020067892A-000-000-0000000-0000 Registration Date/Time: 2018-09-04 20:37:07 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2018-09-04 20:37:06
Schema Version: rev 10/16
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 3 of 3)
Documentation Author's Declaration Statement
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Drew Queen
'Drew Queew
Company:
Signature Date:
I Permit E Raters
2018-09-04
Address:
CEA/ HERS Certification Identification (if applicable):
31225 La Baya Drive
City/State/Zip:
Phone.
Westlake Village CA 91362
818-735-7876
Responsible Person's Declaration statement
I certify the following under penalty of perjury, underthe laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer),
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) Issued for the building, and made available to the enforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate of Compliance & required to be Included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Responsible Designer Signature:
Tracy Garza
TracyQ -�-
Company :
Date Signed:
Votta Enterprises, Inc. dba Comfort Air
2018-09-04
Address:
License:
72248 Northshore Street #101
763937
City/State/Zip: i
Phone:
Thousand Palms CA 92276
760-320-5800
D1gi01ly signed by CHEEASTm. This dip/tal signature Is provided in order to secure the content of this registered
document, and In no way implies Registration Provider responsibility far the accuracy of the informatiah,
Registration Number:418-A020067892A-000-000-0000000-0000 Registration Date/Time: 2018-09-04 20:37:07 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2018-09-04 20:37:06
Schema Version: rev 10/16