BRES2018-0084 Revision 278-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type/Subtype:
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
wit�t 4 441 Q"q&
DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED
BRES2018-0084
53742 ROSS AVE
767680048
DOAN / 6,288SF DWELLING/VB/RES-3/CLASS A-FR/13D
$567,824.50
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Owner:
RICHARD DOAN
POBOX 8014
RANCHO SANTA FE, CA 92067
Date: 9/19/2018
Applicant: 2 -r-, +�1 Contractor:
RICHARD DOAN CONSTRUCTION / ) RICHARD DOAN CONSTRUCTION
P O BOX 8011 L) P O BOX 8011
RANCHO SANTA FE, CA 92067 CC- U" I�� RANCHO SANTA FE, CA 92067
/(858)756-4930
(P /% Llc. No.: 374118
---------------------------------------------------- --------------------------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect_
License Class: B License No.: 374118
Date:
Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
() I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
() I am exempt under Sec. B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: STATE COMPEN5ATION INSURANCE FUND Policy Number: 1908709
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date:
Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
Following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
-onstruction, and hereby authorize representatives of this city to enter upon the
above -mentioned property for inspection purposes.
Date: Signature (Applicant or Agent):
Lender's Address:
Application Number:
BRES2018-0084
Property Address:
53742 ROSS AVE
APN:
767680048
Application Description:
DOAN / 6,288SF DWELLING/VB/RES-3/CLASS A-FR/13D
Property Zoning:
Application Valuation:
$567,824.50
Applicant:
RICHARD DOAN CONSTRUCTION
P 0 BOX 8011
RANCHO SANTA FE, CA 92067
Owner:
RICHARD DOAN
POBOX 8014
RANCHO SANTA FE, CA 92067
Contractor:
RICHARD DOAN CONSTRUCTION
P0BOX 8011
RANCHO SANTA FE, CA 92067
(858)756-4930
Llc. No.: 374118
Date:' 19/19/2018
Detail: 6,288SF SINGLE FAMILY DWELLING [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL, SPA, WATER FEATURES OR
DRIVEWAY APPROACH. 2016 CALIFORNIA BUILDING CODES.
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT CITY AMOUNT
ART IN PUBLIC PLACES - RESIDENTIAL
270-0000-43201 0 $919.56
Total Paid for ART IN PUBLIC PLACES - AIPP: $919.56
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($120.00)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($156.00)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($78.00)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HOURLY CHARGE - CITY BUILDING STAFF
101-0000-42600
1
$156.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HOURLY CHARGE - CITY BUILDING STAFF
101-0000-42600
0.5
$78.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - ESGIL STRUCTURAL ENGINEER
101-0000-42600
1
$120.00
Total Paid for BLDG CITY STAFF - PER HOUR: $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$23.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $23.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
Credit Card Fee
101-0000-43505
0
$21.60
Total Paid for Credit Card Fee: $21.60
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - CIVIC CENTER
252-0000-43200
0
$942.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - COMMUNITY CENTERS
254-0000-43200
0
$129.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - FIRE PROTECTION
257-0000-43200
0
$433.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - LIBRARIES
253-0000-43200
0
$344.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - PARK MAINTENANCE
256-0000-43200
0
$40.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - PARKS/REC
251-0000-43200
0
$2,048.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - STREET MAINTENANCE
255-0000-43200
0
$116.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF-TRANSPORTATION
250-0000-43200
0
$2,842.00
Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TEMP POWER SERVICE
101-0000-42403
0
$26.61
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TEMP POWER SERVICE PC
101-0000-42600
0
$18.20
Total Paid for ELECTRICAL: $44.21
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF
101-0000-42403
0
$119.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF, PC
101-0000-42600
0
$49.14
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$156.04
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$51.49
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $376.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF
101-0000-42408
0
$39.01
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT>7KSF PC
101-0000-42600
0
$195.05
Total Paid for GRADING: $234.06
DESCRIPTION
ACCOUNT
CITY
AMOUNT
AIR HANDLER
101-0000-42402
0
$78.02
DESCRIPTION
ACCOUNT
QTY
AMOUNT
AIR HANDLER PC
101-0000-42600
'10
$26.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
CONDENSER/COMPRESSOR
101-0000-42402
0
$273.07
DESCRIPTION
ACCOUNT
CITY
AMOUNT
CONDENSER/COMPRESSOR PC
101-0000-42600
0
$182.07
DESCRIPTION
ACCOUNT
QTY
AMOUNT
EXHAUST HOOD
101-0000-42402
0
$13.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
EXHAUST HOOD PC
101-0000-42600
0
$5.20
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FURNACE
101-0000-42402
0
$195.05
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FURNACE PC
101-0000-42600
0
$130.05
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN
101-0000-42402
0
$130.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN PC
101-0000-42600
0
$52.00
Total Paid for MECHANICAL: S1.084.46
DESCRIPTION
ACCOUNT CITY
AMOUNT
NEW CONSTRUCTION PERMIT
101-0000-42400 0
$826.64
Total Paid for NEW CONSTRUCTION PERMIT: $826.64
DESCRIPTION
ACCOUNT CITY
AMOUNT
NEW CONSTRUCTION PLAN CHECK
101-0000-42600 0
$1,788.80
Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,788.80
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($181.56)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($143.56)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PATIO COVER, DESIGNED
101-0000-42404
0
$143.56
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PATIO COVER, DESIGNED PC
101-0000-42600
0
$181.56
Total Paid for PATIO COVER / COVERED PORCH / LATTICE: $0.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PLAN CHECK DEPOSIT - RESIDENTIAL
101-0000-42600
1
$1,200.00
Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $1,200.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BACKFLOW DEVICE
101-0000-42401
0
$13.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BACKFLOW DEVICE PC
101-0000-42600
0
$5.20
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BUILDING SEWER
101-0000-42401
0
$26.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BUILDING SEWER PC
101-0000-42600
0
$18.20
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$325.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$325.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 5+ OUTLETS
101-0000-42401
0
$39.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 5+ OUTLETS PC
101-0000-42600
0
$26.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ROOF DRAIN
101-0000-42401
0
$91.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ROOF DRAIN PC
101-0000-42600
0
$91.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER HEATER/VENT
101-0000-42401
0
$26.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER HEATER/VENT PC
101-0000-42600
0
$15.60
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$13.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER SYSTEM INST/ALT/REP PC 101-0000-42600 1 0 $13.J0
Total Paid for PLUMBING FEES: $1,027.03
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RECORDS MANAGEMENT FEE - MAJOR
101-0000-42416
0
$20.00
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $20.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($39.01)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
REPLACEMENT INSPECTION CARD
101-0000-42600
1
$39.01
Total Paid for REPLACEMENT OF PLANS/JOB CARD: $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$73.82
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $73.82
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
DESCRIPTION
ACCOUNT QTY
AMOUNT
SINGLE FAMILY DETACHED
224-0000-20320 0
$1,837.44
Total Paid for TUMF - RESIDENTIAL: $1,837.44
--
PERMIT # J3 ?N 5 o Y f D Q
PLAN LOCATION:
Project Address: 3 7 Je
`
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #:
v ;
ew
Applicant_Name:
Address: V6 Oir
City, ST, Zip: e r iM co
Telephon 0 766_ G U
Email:
-O [
Valuation of Project $
Contractor Name:
R �C�u•1 G
New SFD Construction:
Address:
Conditioned Space
SF
City, St, Zip
Garage
SF
Telephone:
1
Patio/Porch
SF
Email:
Fire Sprinklers
SF
State Lic: •
City Bus Lic:
Arch/Eng Name:
Construction Type: Occupancy:
Address: 1 a ;, !/z
Grading:
City, St, Zip
Telephon'U
Bedrooms:
Stories:
# Units:
Email:
State Lic: City Bus Lic:
Property Owner's Name: C�
New Commercial / Tenant Improvements:
Address:
Total Building SF
City, ST, Zip ,. A
Construction Type: Occupancy:
Telephone:
Email:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
OFFICE USE ONLY
#
Submittal
Req'd
R&'d
Plan Sets
Structural Calcs
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM 10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CFI R-PRF-01
7.,4ect Name: Madison Lot 43A
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:18, Fri, Sep 07, 2018
Input File Name: Madison Lot 43-45A-Radford-17.ribd16x
Page 1 of 13
GENERAL INFORMATION
01
Project Name
Madison Lot 43A
02
Calculation Description
Title 24 Analysis
03
Project Location
Lot 43-A, The Madison Club ,
RE11
FOR
04
City
La Quinta
QQ
DE
Standards Version
Compliance 2017
06
Zip Code
92253
COWLIANCE
Complia
Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
1.09
Software Version
EnergyPro 7.2
10
Building Type
Single Family
tion (deg/Cardinal)
270
12
Project Scope
Newly Constructed
1 :L
2W Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
7556
Number of Zones
5
16
Slab Area (ft)
7556
17
Number of Stories
1
18
Addition Cond. Floor Area(ft2)
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ft2)
n/a
21
Glazing Percentage (%)
23.1 %
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
2.80
4.25
-1.45
-51.8%
Space Cooling
78.49
77.06
1.43
1.8%
IAQ Ventilation
0.69
0.69
0.00
0.0%
Water Heating
1.88
1.63
0.25
Photovoltaic Offset
---
0.00
0.00
--
Compliance Energy Total
83.86
83.63
0.23
0.3%
'RENlkSlkaa 2.
Registration Number: 218-P010252246A-000-0004000000.0000 Registration Date/Time: 2018-09-07 12:28:14
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149
HF 1 CUab
CITY OF LA QUINTA
COMMUNITY [DEVELOPMENT
I r
HERS Provider: CaICERTS inc.
Report Generated at: 2018-09-07 12:20:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
..jcct Name: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018
CF1 R-PRF-01
Page 2 of 13
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 43_45A-Radford-17.ribd16x
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency
EDR of Proposed Efficiency
EDR Value of Proposed PV + Battery Final Proposed EDR
46.3
46.2
1 0.0 46.2
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified.
Notes:
• Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering NEM rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Insulation above roof deck
• Window overhangs and/or fins
'HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below_
Building -level Verifications:
• High quality insulation installation (Qll)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
• -- None --
Registration Number: 218-P010252246A-0O0-000-O000000.0000 Registration DateRme: 2018-09-0712:28:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-07 12:20:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
_ ..gect Name: Madison Lot 43A
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:18, Fri, Sep 07, 2018
Input File Name: Madison Lot 43_45A-Radford-17.ribd16x
CFI R-PRF-01
Page 3 of 13
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Madison Lot 43A
7556
1
4
5
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Master Zone
Conditioned
HVAC Zone 11
1570
11.6
DHW Sys 1
n/a
Living/Kitchen Zone
Conditioned
HVAC Zone 22
2198
14.4
DHW Sys 1
n/a
Bedroom 3 & 4 Zone
Conditioned
HVAC Zone 33
1761
10
DHW Sys 1
n/a
Guest Zone
Conditioned
HVAC Zone 44
759
10
DHW Sys 1
n/a
Garage Zone
Conditioned
HVAC Zone 55
1268
10
DHW Sys 1
n/a
Registration Number: 218-P010252246A-000-000-0000000-0000 Registration Date/Time: 2018-09-0712:28:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 43_45A-Radford-17.ribdl6x
CF1 R-PRF-01
Page 4 of 13
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (W)
Tilt (deg)
N Wall
Master Zone
R-21 Wall (W.21.2x6.16)
0
Left
726
148.1
90
E Wall
Master Zone
R-21 Wall (W.21.2x6.16)
90
Back
348
154
90
S Wall
Master Zone
R-21 Wall (W.21.2x6.16)
180
Right
236
0
90
W Wall
Master Zone
R-21 Wall (W2124.16)
270
Front
100
0
90
Interior Surface
Master Zone»Living/Kitchen Zone
R-0 Interior Wall
n/a
n1a
610
0
n/a
Roof
Master Zone
R-38 Roof Attic w/ R-13
n/a
n/a
1570
n/a
n/a
N Wall 2
Living/Kitchen Zone
R-21 Wall (W.21.24.16)
0
Left
340
50
90
E Wall 2
Living/Kitchen Zone
R-21 Wall (W21.2x6.16)
90
Back
680
606
90
S Wall 2
Living/Kitchen Zone
R-21 Wall (W.21.2x6.16)
180
Right
480
0
90
W Wall 2
Living/Kitchen Zone
R-21 Wall (W.21.2x6.16)
270
Front
420
175
90
Interior Surface 2
Living/Kitchen Zone»Master Zone
R-0 Interior Wall
n/a
n/a
610
0
n/a
Interior Surface 3
Living/Kitchen Zone»Bedroom 3 & 4
Zone
R-0 Interior Wall
n/a
n/a
440
0
n/a
Roof 2
Living/Kitchen Zone
R-38 Attic W/ R-0 ext.
n/a
n/a
2198
n/a
n/a
N Wall 3
Bedroom 3 & 4 Zone
R-21 Wall (W.21.2x6.16)
0
Left
200
0
90
E Wall 3
Bedroom 3 & 4 Zone
R-21 Wall (W.21.2x6.16)
90
Back
300
215.7
90
S Wall 3
Bedroom 3 & 4 Zone
R-21 Wall (W.21.2x6.16)
180
Right
840
108.8
90
W Wall 3
Bedroom 3 & 4 Zone
R-21 Wall (W.21.2x6.16)
270
Front
400
37.5
90
Interior Surface 4
Bedroom 3 & 4 Zone»Living/Kitchen
Zone
R-0 Interior Wall
n/a
n/a
440
0
n/a
Roof 3
Bedroom 3 & 4 Zone
R-38 Roof Attic w/ R-13
n/a
n/a
1761
n/a
n/a
N Wall 4
Guest Zone
R-21 Wall (W21.2x6.16)
0
Left
300
43
90
E Wall 4
Guest Zone
R-21 Wall (W21.2x6.16)
90
Back
20
0
90
S Wall 4
Guest Zone
R-21 Wall (W.21.2x6.16)
180
Right
380
21.6
90
W Wall 4
Guest Zone
R-21 Wall (W21.2x6.16)
270
Front
230
44.1
90
Interior Surface 5
Guest Zone»Master Zone
R-0 Interior Wall
n/a
n/a
300
0
n/a
Roof 4
Guest Zone
R-38 Roof Attic w/ R-13
n/a
n/a
759
n/a
n/a
N Wall 5
Garage Zone
R-21 Wall (W.21.2x6.16)
0
Left
480
36
90
E Wall 5
Garage Zone
R-21 Wall (W.212x6.16)
90
Back
150
0
90
S Wall 5
Garage Zone
R-21 Wall (W.21.2x6.16)
180
Right 1
480
288
90
Registration Number: 218-P010252246A-000-000-0000000-0000 Registration Date/Time: 2018-09-0712:28:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1R-PRF-01
Project Name: Madison Lot 43A
Calculation Date/Time: 12:18, Fri, Sep 07, 2018
Page 5 of 13
Calculation Description: 1-itfe 24 Anafysis
input File Name: Madison Lot 43 45A-Radford-17.dbd16x
W Wall 5
Garage Zone
R-21 Wall (W.21.2x6.16)
270
Front
275
25
90
Interior Surface 6
Garage Zone»Master Zone
R-0 Interior Wall
n/a
n/a
300
0
n/a
Roof 5 Garage Zone
R-38 Roof Attic w/ R-13
n/a
n/a
J
1268
n/a
n/a
ATTIC
01
02
03
04
06
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Master Zone
Attic RoofMaster Zone
Unventilated
3
0.1
0.85
Yes
No
Attic Living/Kitchen Zone
Attic RoofLiving/Kitchen
Zone
Unventilated
3
0.1
0.85
Yes
No
Attic Bedroom 3 & 4 Zone
Attic RoofBedroom 3 & 4
Zone
Unventilated
3
0.1
0.85
Yes
No
Attic Guest Zone
Attic RoofGuest Zone
Unventilated
3
0.1
0.85
Yes
No
Attic Garage Zone
Attic RoofGarage Zone
Unventilated
3
0.1
0.85
Yes
No
Registration Number: 218-P010252246A-000-000-0000000-0000 Registration Date/Time: 2018-09-07 12:28:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09
CFI R-PRF-01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 43-45A-Radford-17.ribdl6x
Page 6 of 13
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
S-3X4.5
Window
N Wall (Left-0)
-
--
1
13.5
0.52
0.26
Insect Screen (default)
R-2.5X2.5
Window
N Wall (Left-0)
--
1
6.3
0.53
0.27
Insect Screen (default)
Q-4X3
Window
N Wall (Left-0)
--
---
1
12.0
0.39
0.33
Insect Screen (default)
P-8X10
Window
N Wall (Left-0)
8.0
10.0
Ei
80.0
0.86
0.71
Insect Screen (default)
0-2.5X2.5
Window
N Wall (Left-0)
--
-
1
6.3
0.53
0.27
Insect Screen (default)
N-3X5
Window
N Wall (Left-0)
---
--
1
15.0
0.39
0.33
Insect Screen (default)
M-3X5
Window
N Wall (Left-0)
----
--
1
15.0
0.39
0.33
Insect Screen (default)
7-14XIl
Window
E Wall (Back-90)
14.0
10.0
1.1
154.0
0.52
0.31
Insect Screen (default)
A-5X10
Window
N Wall 2 (Left-0)
--
--
1
50.0
0.39
0.33
Insect Screen (default)
5-40X12
Window
E Wall 2 (Back-90)
40.0
12.0
1
480.0
0.52
0.31
Insect Screen (default)
L-9X3.5
Window
E Wall 2 (Back-90)
--
---
1
31.5
0.39
0.33
Insect Screen (default)
L-9X3.5 2
Window
E Wall 2 (Back-90)
-.--
-
1
31.5
0.39
0.33
Insect Screen (default)
L-9X3.5 3
Window
E Wall 2 (Back-90)
-
-
1
31.5
0.39
0.33
Insect Screen (default)
L-9X3.5 4
Window
E Wall 2 (Back-90)
-
-
1
31.5
0.39
0.33
Insect Screen (default)
A-7.5X10
Window
W Wall 2 (Front-270)
----
--
1
75.0
0.39
0.33
Insect Screen (default)
1-7X10
Window
W Wall 2 (Front-270)
7.0
10.0
1
70.0
0.52
0.31
Insect Screen (default)
X-5X6.2
Window
W Wall 2 (Front-270)
7.5
4.0
1
30.0
0.39
0.33
Insect Screen (default)
4-18.7X11
Window
E Wall 3 (Back-90)
18.7
10.0
1.1
205.7
0.52
0.31
Insect Screen (default)
K-2X5
Window
E Wall 3 (Back-90)
---
--
1
10.0
0.52
0.26
Insect Screen (default)
J-3X4
Window
S Wall 3 (Right-180)
-
---
1
12.0
0.39
0.33
Insect Screen (default)
1-2.5X2.5
Window
S Wall 3 (Right-180)
--
---
1
6.3
0.53
0.27
Insect Screen (default)
G-6X10
Window
S Wall 3 (Right-180)
-
1
60.0
0.39
0.33
Insect Screen (default)
F-2.5X5
Window
S Wall 3 (Right-180)
-
1
12.5
0.52
0.26
Insect Screen (default)
E-4X4.5
Window
S Wall 3 (Right-180)
-
1
18.0
0.52
0.26
Insect Screen (default)
H-7.5X5
Window
W Wall 3 (Front-270)
-
---
1
37.5
0.39
0.33
Insect Screen (default)
V-3X4.5
Window
N Wall 4 (Left-0)
3.0
3.0
1.5
13.5
0.52
0.26
Insect Screen (default)
U-3X1.5
Window
N Wall 4 (Left-0)
3.0
3.0
1.5
13.5
0.52
0.26
Insect Screen (default)
T-4X4
Window
N Wall 4 (Left-0)
---
--
1
16.0
0.39
0.33
Insect Screen (default)
8-2.7X8
Window
S Wall 4 (Right-180)
--
-
1
21.6
0.52
0.31
Insect Screen (default)
Registration Number: 218-P010252246A-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration Date/Time: 2016-09-07 12:28:14
Report Version - CF1 R-06282018-1149
HERS Provider: CaICERTS inc.
Report Generated at 2018-09-07 12:20:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 43-45A-Radford-17.ribdl6x
CFI R-PRF-01
Page 7 of 13
W 7X6.3
Window
W Wall 4 (Front-270)
-
--
1
44.1
0.39
0.33
Insect Screen (default)
B-4X4.5
Window
N Wall 5 (Left 0)
--
-
1
18.0
0.39
0.33
Insect Screen (default)
C-4X4.5
Window
N Wall 5 (Left-0)
-
-
1
18.0
0.39
0.33
Insect Screen (default)
Window -Garage Door
Window
S Wall 5 (Right-180)
-
-
1
40.1
0.50 1
0.50
Insect Screen (default)
Window -Garage Door 2
Window
S Wall 5 (Right-180)
-
-
1
40.1
0.50
0.50
Insect Screen (default)
D-5X5
Window
W Wall 5 (Front-270)
---
---
1
25.0
0.39
0.33
Insect Screen (default)
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (W)
U-factor
Opaque Garage Door
S Wall 5
103.9
0.30
Opaque Garage Door 2
S Wall 5
103.9
0.30
OVERHANGS AND FINS
01
02
03 04
05
06
07
08
09
10 1
11
12
13
14
Overhang
Left Fin
Right
Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
P-8X10
2
0.1
2
2
0
0
0
0
0
0
0
0
0
7-14X11
2
0.1
2
2
0
0
0
0
0
0
0
0
0
5-40X12
22
0.1
22
22
0
0
0
0
0
0
0
0
0
1-7X10
12
0.1
12
12
0
0
0
0
0
0
0
0
0
X-5X6.2
18
0.1
18
18
0
0
0
0
0
0
0
0
0
4-18.7X11
2
0.1
2
2
0
0
0
0
0
0
0
0
0
V-3X4.5
2
0.1
2
2
0
0
0
0
0
0
0
0
0
U-3X1.5
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Registration Number: 218-Po10252246A-000-000-0000000-0000 Registration Date/Time: 2018-09-07 12:28:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CFI R-PRF-01
Project Name: Madison Lot 43A
Calculation Description: Title 24 Analysis
Calculation DatelTime: 12:18, Fri, Sep 07, 2018
Input File Name: Madison Lot 43 45A-Radford-17.ribdl6x
Page 8 of 13
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
• Around Roof Joists: R-0.0 insul.
• Cavity/ Frame: R-13.0 / 2x4 Top Chid
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofMaster Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing. Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic w/ R-13
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Ceiling Joists. R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
R-21 Wall (W.21.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
• Cavity / Frame: no insul. / 2x4
R-0 Interior Wall
Interior Walls i
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.277
Other Side Finish: Gypsum Board
• Cavity/Frame: no insul. /2x4 Top Chrd
• Roof Deck Wood Siding/sheathing/decking
2x4 Top Chord of Roof Truss @ 24
• Above Deck Insulation: R6 Sheathing
Attic RoofLiving/Kitchen Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.131
- Roofing. Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
• Cavity/Frame: R-9.1 /2x4
R-38 Attic W/ R-6 ext.
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
- Over Ceiling Joists: R-28.9 insul.
• Around Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chid
2x4 Top Chord of Roof Truss @ 24
• Roof Deck. Wood Siding/sheathing(decking
Attic RoofBedroom 3 & 4 Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
• Roofing. Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chid
2x4 Top Chord of Roof Truss @ 24
Roof Deck. Wood Siding/sheathing/decking
Attic RoofGuest Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chid
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofGarage Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing. Light Roof (Asphalt Shingle)
Registration Number: 218-P010252246A-000-000-0000000-0000 Registration Date/Time: 2018-09-07 12:28:14 HERS Provider. CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CFI R-PRF-01
Project Name: Madison Lot 43A
Calculation Description: Title 24 Analysis
Calculation Daterrime: 12:18, Fri, Sep 07, 2018
Input File Name: Madison Lot 43 46A-Radford-17.ribdl6x
Page 9 of 13
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (W)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Slab
Master Zone
1570
120
None
0.8
No
Slab 2
Living/Kitchen Zone
2198
102
None
0.8
No
Slab 3
Bedroom 3 & 4 Zone
1761
162
None
0.8
No
Slab 4
Guest Zone
759
89
None
0.8
No
Slab 5
Garage Zone
1268
89
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1 (2)
2
.0%
WATER HEATERS
01
02
03
04
05
06
07
08 1
09
10
11
12
Input Rating /
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
NEEA Heat Pump
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
Brand 1 Model /
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Other
Condition
DHW Heater 1
Gas
Small
Instantaneous
2
0
0.95 EF
<= 200 kBtu/hr
R-0/R-0
0
n/a
n/a
n/a
Registration Number: 218-P010252246A-000-000-0000000-WW Registration Date/Time: 2018-09-0712:28:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project dame: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 43_45A-Radford-17.ribd16x
CFI R-PRF-01
Page 10 of 13
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC Zone 11
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC Zone 22
Other Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
HVAC Zone 33
Other Heating and Cooling
System
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
HVAC Zone 44
Other Heating and Cooling
System
Heating Component 4
Cooling Component 4
HVAC Fan 4
Air Distribution System 4
HVAC Zone 55
Heat Pump Heating and
Cooling System
Heat Pump System 5
Heat Pump System 5
None
- none -
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFumace
1
80 AFUE
Heating Component 2
CntrlFumace
2
80 AFUE
Heating Component 3
CntrlFumace
1
80 AFUE
Heating Component 4
CntrlFurnace
1
80 AFUE
HVAC - HEAT PUMPS
01
02
03
04
05
06
07
08
09
10
11
Name
System
Type
Number of
Units
Heating
Cooling
Zonally
Controlled
Compressor
Type
HERS
Verification
HSPF/COP
Cap 47
Cap 17
SEER
EER
Heat Pump System 5
DuctlessMiniSplitHeatPump
1
12.3
26000
15400
18
13.5
Not Zonal
Single Speed
Heat Pump System
5-hers-cool
Registration Number: 218-P010252246A-000-000-0000000-0000 Registration Date/Time: 2018-09-07 12:28:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018
CF1 R-PRF-01
Page 11 of 13
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 43_45A-Radford-17.ribd16x
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Efficiency
Name
System Type
Number of Units
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Cooling Component 2
SplitAirCond
2
13
16
Not Zonal
Single Speed
Cooling Component
2-hers-cool
Cooling Component 3
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
3-hers-cool
Cooling Component 4
SplitAirCond
1
13.5
17
Not Zonal
Single Speed
Cooling Component
4-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Cooling Component 2-hers-cool
Required
350
Required
Required
Required
Cooling Component 3-hers-cool
Required
350
Required
Required
Required
Cooling Component 4-hers-cool
Required
350
Required
Required
Required
Heat Pump System 5-hers-cool
Not Required
n/a
Not Required
Not Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
1-hers-dist
Air Distribution System 2
DuctsAttic
Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
2-hersAist
Air Distribution System 3
DuctsAttic
Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
3-hers-dist
Air Distribution System 4
DuctsAttic
Specified Lower Leakage 1
Target
8
Attic
None
Air Distribution System
4-hens-list
Registration Number: 218-P010252246A-000-000-0000000-0000 Registration DateRme: 2018-09-0712:28:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 43_45A-Radford-17.ribd16x
CF1 R-PRF-01
Page 12 of 13
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low4eakage
Air Handler
Air Distribution System 1-hers-0ist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 2-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 3-hers-0ist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 4-hers-0ist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.52
HVAC Fan 1-hers-fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.52
HVAC Fan 2-hers-fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.52
HVAC Fan 3-hers-fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.52
HVAC Fan 4-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.52
HVAC Fan 2-hers-fan
Required
0.52
HVAC Fan 3-hers-fan
Required
0.52
HVAC Fan 4-hers-fan
Required
0.52
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
113
0.25
Default
0
Required
Registration Number: 218-P010252246A-000-000-0000000-0000 Registration Date/Time: 2018-09-07 12:28:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 43_45A-Radford-17.ribd16x
CFI R-PRF-01
Page 13 of 13
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Tc•rr�-��a
Company:
Signature Date:
Scott Design and Title 24, Inc.
2018-09-0712:28:14
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Tim Scott
Company:
Date Signed:
Scott Design and Title 24, Inc.
2018-09-07 12:28:14
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
Easy to Verify
at CaICERTS.com
Registration Number: 218-Po10252246A-000-000-0000000-0000 Registration Date/Time: 2018-09-07 12:28:14
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149
HERS Provider: CaICERTS inc.