Loading...
BRES2018-0084 Revision 278-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: wit�t 4 441 Q"q& DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED BRES2018-0084 53742 ROSS AVE 767680048 DOAN / 6,288SF DWELLING/VB/RES-3/CLASS A-FR/13D $567,824.50 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: RICHARD DOAN POBOX 8014 RANCHO SANTA FE, CA 92067 Date: 9/19/2018 Applicant: 2 -r-, +�1 Contractor: RICHARD DOAN CONSTRUCTION / ) RICHARD DOAN CONSTRUCTION P O BOX 8011 L) P O BOX 8011 RANCHO SANTA FE, CA 92067 CC- U" I�� RANCHO SANTA FE, CA 92067 /(858)756-4930 (P /% Llc. No.: 374118 ---------------------------------------------------- -------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect_ License Class: B License No.: 374118 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: () I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). () I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: STATE COMPEN5ATION INSURANCE FUND Policy Number: 1908709 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or Following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building -onstruction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. Date: Signature (Applicant or Agent): Lender's Address: Application Number: BRES2018-0084 Property Address: 53742 ROSS AVE APN: 767680048 Application Description: DOAN / 6,288SF DWELLING/VB/RES-3/CLASS A-FR/13D Property Zoning: Application Valuation: $567,824.50 Applicant: RICHARD DOAN CONSTRUCTION P 0 BOX 8011 RANCHO SANTA FE, CA 92067 Owner: RICHARD DOAN POBOX 8014 RANCHO SANTA FE, CA 92067 Contractor: RICHARD DOAN CONSTRUCTION P0BOX 8011 RANCHO SANTA FE, CA 92067 (858)756-4930 Llc. No.: 374118 Date:' 19/19/2018 Detail: 6,288SF SINGLE FAMILY DWELLING [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL, SPA, WATER FEATURES OR DRIVEWAY APPROACH. 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT CITY AMOUNT ART IN PUBLIC PLACES - RESIDENTIAL 270-0000-43201 0 $919.56 Total Paid for ART IN PUBLIC PLACES - AIPP: $919.56 DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($120.00) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($156.00) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($78.00) DESCRIPTION ACCOUNT CITY AMOUNT HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 1 $156.00 DESCRIPTION ACCOUNT CITY AMOUNT HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 0.5 $78.00 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - ESGIL STRUCTURAL ENGINEER 101-0000-42600 1 $120.00 Total Paid for BLDG CITY STAFF - PER HOUR: $0.00 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $23.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $23.00 DESCRIPTION ACCOUNT CITY AMOUNT Credit Card Fee 101-0000-43505 0 $21.60 Total Paid for Credit Card Fee: $21.60 DESCRIPTION ACCOUNT CITY AMOUNT DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - LIBRARIES 253-0000-43200 0 $344.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - PARKS/REC 251-0000-43200 0 $2,048.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF-TRANSPORTATION 250-0000-43200 0 $2,842.00 Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 DESCRIPTION ACCOUNT CITY AMOUNT TEMP POWER SERVICE 101-0000-42403 0 $26.61 DESCRIPTION ACCOUNT CITY AMOUNT TEMP POWER SERVICE PC 101-0000-42600 0 $18.20 Total Paid for ELECTRICAL: $44.21 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $119.34 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $49.14 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $156.04 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $51.49 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $376.01 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF 101-0000-42408 0 $39.01 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT>7KSF PC 101-0000-42600 0 $195.05 Total Paid for GRADING: $234.06 DESCRIPTION ACCOUNT CITY AMOUNT AIR HANDLER 101-0000-42402 0 $78.02 DESCRIPTION ACCOUNT QTY AMOUNT AIR HANDLER PC 101-0000-42600 '10 $26.00 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $273.07 DESCRIPTION ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $182.07 DESCRIPTION ACCOUNT QTY AMOUNT EXHAUST HOOD 101-0000-42402 0 $13.00 DESCRIPTION ACCOUNT QTY AMOUNT EXHAUST HOOD PC 101-0000-42600 0 $5.20 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE 101-0000-42402 0 $195.05 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE PC 101-0000-42600 0 $130.05 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN 101-0000-42402 0 $130.00 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN PC 101-0000-42600 0 $52.00 Total Paid for MECHANICAL: S1.084.46 DESCRIPTION ACCOUNT CITY AMOUNT NEW CONSTRUCTION PERMIT 101-0000-42400 0 $826.64 Total Paid for NEW CONSTRUCTION PERMIT: $826.64 DESCRIPTION ACCOUNT CITY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,788.80 Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,788.80 DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($181.56) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($143.56) DESCRIPTION ACCOUNT CITY AMOUNT PATIO COVER, DESIGNED 101-0000-42404 0 $143.56 DESCRIPTION ACCOUNT CITY AMOUNT PATIO COVER, DESIGNED PC 101-0000-42600 0 $181.56 Total Paid for PATIO COVER / COVERED PORCH / LATTICE: $0.00 DESCRIPTION ACCOUNT CITY AMOUNT PLAN CHECK DEPOSIT - RESIDENTIAL 101-0000-42600 1 $1,200.00 Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $1,200.00 DESCRIPTION ACCOUNT CITY AMOUNT BACKFLOW DEVICE 101-0000-42401 0 $13.00 DESCRIPTION ACCOUNT CITY AMOUNT BACKFLOW DEVICE PC 101-0000-42600 0 $5.20 DESCRIPTION ACCOUNT CITY AMOUNT BUILDING SEWER 101-0000-42401 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT BUILDING SEWER PC 101-0000-42600 0 $18.20 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $325.00 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $325.00 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $39.01 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT ROOF DRAIN 101-0000-42401 0 $91.00 DESCRIPTION ACCOUNT CITY AMOUNT ROOF DRAIN PC 101-0000-42600 0 $91.00 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $26.00 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $15.60 DESCRIPTION ACCOUNT CITY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $13.00 DESCRIPTION ACCOUNT CITY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 1 0 $13.J0 Total Paid for PLUMBING FEES: $1,027.03 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $20.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $20.00 DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($39.01) DESCRIPTION ACCOUNT CITY AMOUNT REPLACEMENT INSPECTION CARD 101-0000-42600 1 $39.01 Total Paid for REPLACEMENT OF PLANS/JOB CARD: $0.00 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $73.82 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $73.82 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT QTY AMOUNT SINGLE FAMILY DETACHED 224-0000-20320 0 $1,837.44 Total Paid for TUMF - RESIDENTIAL: $1,837.44 -- PERMIT # J3 ?N 5 o Y f D Q PLAN LOCATION: Project Address: 3 7 Je ` Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: v ; ew Applicant_Name: Address: V6 Oir City, ST, Zip: e r iM co Telephon 0 766_ G U Email: -O [ Valuation of Project $ Contractor Name: R �C�u•1 G New SFD Construction: Address: Conditioned Space SF City, St, Zip Garage SF Telephone: 1 Patio/Porch SF Email: Fire Sprinklers SF State Lic: • City Bus Lic: Arch/Eng Name: Construction Type: Occupancy: Address: 1 a ;, !/z Grading: City, St, Zip Telephon'U Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: C� New Commercial / Tenant Improvements: Address: Total Building SF City, ST, Zip ,. A Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal Req'd R&'d Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM 10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R-PRF-01 7.,4ect Name: Madison Lot 43A Calculation Description: Title 24 Analysis Calculation Date/Time: 12:18, Fri, Sep 07, 2018 Input File Name: Madison Lot 43-45A-Radford-17.ribd16x Page 1 of 13 GENERAL INFORMATION 01 Project Name Madison Lot 43A 02 Calculation Description Title 24 Analysis 03 Project Location Lot 43-A, The Madison Club , RE11 FOR 04 City La Quinta QQ DE Standards Version Compliance 2017 06 Zip Code 92253 COWLIANCE Complia Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 1.09 Software Version EnergyPro 7.2 10 Building Type Single Family tion (deg/Cardinal) 270 12 Project Scope Newly Constructed 1 :L 2W Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 7556 Number of Zones 5 16 Slab Area (ft) 7556 17 Number of Stories 1 18 Addition Cond. Floor Area(ft2) n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) n/a 21 Glazing Percentage (%) 23.1 % COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.80 4.25 -1.45 -51.8% Space Cooling 78.49 77.06 1.43 1.8% IAQ Ventilation 0.69 0.69 0.00 0.0% Water Heating 1.88 1.63 0.25 Photovoltaic Offset --- 0.00 0.00 -- Compliance Energy Total 83.86 83.63 0.23 0.3% 'RENlkSlkaa 2. Registration Number: 218-P010252246A-000-0004000000.0000 Registration Date/Time: 2018-09-07 12:28:14 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 HF 1 CUab CITY OF LA QUINTA COMMUNITY [DEVELOPMENT I r HERS Provider: CaICERTS inc. Report Generated at: 2018-09-07 12:20:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD ..jcct Name: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018 CF1 R-PRF-01 Page 2 of 13 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 43_45A-Radford-17.ribd16x ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 46.3 46.2 1 0.0 46.2 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering NEM rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Insulation above roof deck • Window overhangs and/or fins 'HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below_ Building -level Verifications: • High quality insulation installation (Qll) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • -- None -- Registration Number: 218-P010252246A-0O0-000-O000000.0000 Registration DateRme: 2018-09-0712:28:14 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06282018-1149 Report Generated at: 2018-09-07 12:20:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD _ ..gect Name: Madison Lot 43A Calculation Description: Title 24 Analysis Calculation Date/Time: 12:18, Fri, Sep 07, 2018 Input File Name: Madison Lot 43_45A-Radford-17.ribd16x CFI R-PRF-01 Page 3 of 13 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Madison Lot 43A 7556 1 4 5 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Master Zone Conditioned HVAC Zone 11 1570 11.6 DHW Sys 1 n/a Living/Kitchen Zone Conditioned HVAC Zone 22 2198 14.4 DHW Sys 1 n/a Bedroom 3 & 4 Zone Conditioned HVAC Zone 33 1761 10 DHW Sys 1 n/a Guest Zone Conditioned HVAC Zone 44 759 10 DHW Sys 1 n/a Garage Zone Conditioned HVAC Zone 55 1268 10 DHW Sys 1 n/a Registration Number: 218-P010252246A-000-000-0000000-0000 Registration Date/Time: 2018-09-0712:28:14 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 43_45A-Radford-17.ribdl6x CF1 R-PRF-01 Page 4 of 13 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (W) Tilt (deg) N Wall Master Zone R-21 Wall (W.21.2x6.16) 0 Left 726 148.1 90 E Wall Master Zone R-21 Wall (W.21.2x6.16) 90 Back 348 154 90 S Wall Master Zone R-21 Wall (W.21.2x6.16) 180 Right 236 0 90 W Wall Master Zone R-21 Wall (W2124.16) 270 Front 100 0 90 Interior Surface Master Zone»Living/Kitchen Zone R-0 Interior Wall n/a n1a 610 0 n/a Roof Master Zone R-38 Roof Attic w/ R-13 n/a n/a 1570 n/a n/a N Wall 2 Living/Kitchen Zone R-21 Wall (W.21.24.16) 0 Left 340 50 90 E Wall 2 Living/Kitchen Zone R-21 Wall (W21.2x6.16) 90 Back 680 606 90 S Wall 2 Living/Kitchen Zone R-21 Wall (W.21.2x6.16) 180 Right 480 0 90 W Wall 2 Living/Kitchen Zone R-21 Wall (W.21.2x6.16) 270 Front 420 175 90 Interior Surface 2 Living/Kitchen Zone»Master Zone R-0 Interior Wall n/a n/a 610 0 n/a Interior Surface 3 Living/Kitchen Zone»Bedroom 3 & 4 Zone R-0 Interior Wall n/a n/a 440 0 n/a Roof 2 Living/Kitchen Zone R-38 Attic W/ R-0 ext. n/a n/a 2198 n/a n/a N Wall 3 Bedroom 3 & 4 Zone R-21 Wall (W.21.2x6.16) 0 Left 200 0 90 E Wall 3 Bedroom 3 & 4 Zone R-21 Wall (W.21.2x6.16) 90 Back 300 215.7 90 S Wall 3 Bedroom 3 & 4 Zone R-21 Wall (W.21.2x6.16) 180 Right 840 108.8 90 W Wall 3 Bedroom 3 & 4 Zone R-21 Wall (W.21.2x6.16) 270 Front 400 37.5 90 Interior Surface 4 Bedroom 3 & 4 Zone»Living/Kitchen Zone R-0 Interior Wall n/a n/a 440 0 n/a Roof 3 Bedroom 3 & 4 Zone R-38 Roof Attic w/ R-13 n/a n/a 1761 n/a n/a N Wall 4 Guest Zone R-21 Wall (W21.2x6.16) 0 Left 300 43 90 E Wall 4 Guest Zone R-21 Wall (W21.2x6.16) 90 Back 20 0 90 S Wall 4 Guest Zone R-21 Wall (W.21.2x6.16) 180 Right 380 21.6 90 W Wall 4 Guest Zone R-21 Wall (W21.2x6.16) 270 Front 230 44.1 90 Interior Surface 5 Guest Zone»Master Zone R-0 Interior Wall n/a n/a 300 0 n/a Roof 4 Guest Zone R-38 Roof Attic w/ R-13 n/a n/a 759 n/a n/a N Wall 5 Garage Zone R-21 Wall (W.21.2x6.16) 0 Left 480 36 90 E Wall 5 Garage Zone R-21 Wall (W.212x6.16) 90 Back 150 0 90 S Wall 5 Garage Zone R-21 Wall (W.21.2x6.16) 180 Right 1 480 288 90 Registration Number: 218-P010252246A-000-000-0000000-0000 Registration Date/Time: 2018-09-0712:28:14 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018 Page 5 of 13 Calculation Description: 1-itfe 24 Anafysis input File Name: Madison Lot 43 45A-Radford-17.dbd16x W Wall 5 Garage Zone R-21 Wall (W.21.2x6.16) 270 Front 275 25 90 Interior Surface 6 Garage Zone»Master Zone R-0 Interior Wall n/a n/a 300 0 n/a Roof 5 Garage Zone R-38 Roof Attic w/ R-13 n/a n/a J 1268 n/a n/a ATTIC 01 02 03 04 06 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Master Zone Attic RoofMaster Zone Unventilated 3 0.1 0.85 Yes No Attic Living/Kitchen Zone Attic RoofLiving/Kitchen Zone Unventilated 3 0.1 0.85 Yes No Attic Bedroom 3 & 4 Zone Attic RoofBedroom 3 & 4 Zone Unventilated 3 0.1 0.85 Yes No Attic Guest Zone Attic RoofGuest Zone Unventilated 3 0.1 0.85 Yes No Attic Garage Zone Attic RoofGarage Zone Unventilated 3 0.1 0.85 Yes No Registration Number: 218-P010252246A-000-000-0000000-0000 Registration Date/Time: 2018-09-07 12:28:14 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09 CFI R-PRF-01 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 43-45A-Radford-17.ribdl6x Page 6 of 13 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading S-3X4.5 Window N Wall (Left-0) - -- 1 13.5 0.52 0.26 Insect Screen (default) R-2.5X2.5 Window N Wall (Left-0) -- 1 6.3 0.53 0.27 Insect Screen (default) Q-4X3 Window N Wall (Left-0) -- --- 1 12.0 0.39 0.33 Insect Screen (default) P-8X10 Window N Wall (Left-0) 8.0 10.0 Ei 80.0 0.86 0.71 Insect Screen (default) 0-2.5X2.5 Window N Wall (Left-0) -- - 1 6.3 0.53 0.27 Insect Screen (default) N-3X5 Window N Wall (Left-0) --- -- 1 15.0 0.39 0.33 Insect Screen (default) M-3X5 Window N Wall (Left-0) ---- -- 1 15.0 0.39 0.33 Insect Screen (default) 7-14XIl Window E Wall (Back-90) 14.0 10.0 1.1 154.0 0.52 0.31 Insect Screen (default) A-5X10 Window N Wall 2 (Left-0) -- -- 1 50.0 0.39 0.33 Insect Screen (default) 5-40X12 Window E Wall 2 (Back-90) 40.0 12.0 1 480.0 0.52 0.31 Insect Screen (default) L-9X3.5 Window E Wall 2 (Back-90) -- --- 1 31.5 0.39 0.33 Insect Screen (default) L-9X3.5 2 Window E Wall 2 (Back-90) -.-- - 1 31.5 0.39 0.33 Insect Screen (default) L-9X3.5 3 Window E Wall 2 (Back-90) - - 1 31.5 0.39 0.33 Insect Screen (default) L-9X3.5 4 Window E Wall 2 (Back-90) - - 1 31.5 0.39 0.33 Insect Screen (default) A-7.5X10 Window W Wall 2 (Front-270) ---- -- 1 75.0 0.39 0.33 Insect Screen (default) 1-7X10 Window W Wall 2 (Front-270) 7.0 10.0 1 70.0 0.52 0.31 Insect Screen (default) X-5X6.2 Window W Wall 2 (Front-270) 7.5 4.0 1 30.0 0.39 0.33 Insect Screen (default) 4-18.7X11 Window E Wall 3 (Back-90) 18.7 10.0 1.1 205.7 0.52 0.31 Insect Screen (default) K-2X5 Window E Wall 3 (Back-90) --- -- 1 10.0 0.52 0.26 Insect Screen (default) J-3X4 Window S Wall 3 (Right-180) - --- 1 12.0 0.39 0.33 Insect Screen (default) 1-2.5X2.5 Window S Wall 3 (Right-180) -- --- 1 6.3 0.53 0.27 Insect Screen (default) G-6X10 Window S Wall 3 (Right-180) - 1 60.0 0.39 0.33 Insect Screen (default) F-2.5X5 Window S Wall 3 (Right-180) - 1 12.5 0.52 0.26 Insect Screen (default) E-4X4.5 Window S Wall 3 (Right-180) - 1 18.0 0.52 0.26 Insect Screen (default) H-7.5X5 Window W Wall 3 (Front-270) - --- 1 37.5 0.39 0.33 Insect Screen (default) V-3X4.5 Window N Wall 4 (Left-0) 3.0 3.0 1.5 13.5 0.52 0.26 Insect Screen (default) U-3X1.5 Window N Wall 4 (Left-0) 3.0 3.0 1.5 13.5 0.52 0.26 Insect Screen (default) T-4X4 Window N Wall 4 (Left-0) --- -- 1 16.0 0.39 0.33 Insect Screen (default) 8-2.7X8 Window S Wall 4 (Right-180) -- - 1 21.6 0.52 0.31 Insect Screen (default) Registration Number: 218-P010252246A-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2016-09-07 12:28:14 Report Version - CF1 R-06282018-1149 HERS Provider: CaICERTS inc. Report Generated at 2018-09-07 12:20:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 43-45A-Radford-17.ribdl6x CFI R-PRF-01 Page 7 of 13 W 7X6.3 Window W Wall 4 (Front-270) - -- 1 44.1 0.39 0.33 Insect Screen (default) B-4X4.5 Window N Wall 5 (Left 0) -- - 1 18.0 0.39 0.33 Insect Screen (default) C-4X4.5 Window N Wall 5 (Left-0) - - 1 18.0 0.39 0.33 Insect Screen (default) Window -Garage Door Window S Wall 5 (Right-180) - - 1 40.1 0.50 1 0.50 Insect Screen (default) Window -Garage Door 2 Window S Wall 5 (Right-180) - - 1 40.1 0.50 0.50 Insect Screen (default) D-5X5 Window W Wall 5 (Front-270) --- --- 1 25.0 0.39 0.33 Insect Screen (default) OPAQUE DOORS 01 02 03 04 Name Side of Building Area (W) U-factor Opaque Garage Door S Wall 5 103.9 0.30 Opaque Garage Door 2 S Wall 5 103.9 0.30 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 1 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up P-8X10 2 0.1 2 2 0 0 0 0 0 0 0 0 0 7-14X11 2 0.1 2 2 0 0 0 0 0 0 0 0 0 5-40X12 22 0.1 22 22 0 0 0 0 0 0 0 0 0 1-7X10 12 0.1 12 12 0 0 0 0 0 0 0 0 0 X-5X6.2 18 0.1 18 18 0 0 0 0 0 0 0 0 0 4-18.7X11 2 0.1 2 2 0 0 0 0 0 0 0 0 0 V-3X4.5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 U-3X1.5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 218-Po10252246A-000-000-0000000-0000 Registration Date/Time: 2018-09-07 12:28:14 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R-PRF-01 Project Name: Madison Lot 43A Calculation Description: Title 24 Analysis Calculation DatelTime: 12:18, Fri, Sep 07, 2018 Input File Name: Madison Lot 43 45A-Radford-17.ribdl6x Page 8 of 13 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Around Roof Joists: R-0.0 insul. • Cavity/ Frame: R-13.0 / 2x4 Top Chid 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofMaster Zone Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing. Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic w/ R-13 attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Ceiling Joists. R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Cavity / Frame: no insul. / 2x4 R-0 Interior Wall Interior Walls i Wood Framed Wall 2x4 @ 16 in. O.C. none 0.277 Other Side Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 Top Chrd • Roof Deck Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss @ 24 • Above Deck Insulation: R6 Sheathing Attic RoofLiving/Kitchen Zone Attic Roofs Wood Framed Ceiling in. O.C. none 0.131 - Roofing. Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below • Cavity/Frame: R-9.1 /2x4 R-38 Attic W/ R-6 ext. attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 - Over Ceiling Joists: R-28.9 insul. • Around Roof Joists: R-0.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chid 2x4 Top Chord of Roof Truss @ 24 • Roof Deck. Wood Siding/sheathing(decking Attic RoofBedroom 3 & 4 Zone Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 • Roofing. Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chid 2x4 Top Chord of Roof Truss @ 24 Roof Deck. Wood Siding/sheathing/decking Attic RoofGuest Zone Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chid 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofGarage Zone Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing. Light Roof (Asphalt Shingle) Registration Number: 218-P010252246A-000-000-0000000-0000 Registration Date/Time: 2018-09-07 12:28:14 HERS Provider. CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R-PRF-01 Project Name: Madison Lot 43A Calculation Description: Title 24 Analysis Calculation Daterrime: 12:18, Fri, Sep 07, 2018 Input File Name: Madison Lot 43 46A-Radford-17.ribdl6x Page 9 of 13 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (W) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab Master Zone 1570 120 None 0.8 No Slab 2 Living/Kitchen Zone 2198 102 None 0.8 No Slab 3 Bedroom 3 & 4 Zone 1761 162 None 0.8 No Slab 4 Guest Zone 759 89 None 0.8 No Slab 5 Garage Zone 1268 89 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 (2) 2 .0% WATER HEATERS 01 02 03 04 05 06 07 08 1 09 10 11 12 Input Rating / Tank Standby Heater Tank Uniform Energy Pilot / Insulation Loss / First Hour NEEA Heat Pump Tank Location Element Number Volume Factor / Energy Thermal R-value Recovery Rating / Brand 1 Model / or Ambient Name Type Tank Type of Units (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Other Condition DHW Heater 1 Gas Small Instantaneous 2 0 0.95 EF <= 200 kBtu/hr R-0/R-0 0 n/a n/a n/a Registration Number: 218-P010252246A-000-000-0000000-WW Registration Date/Time: 2018-09-0712:28:14 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project dame: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 43_45A-Radford-17.ribd16x CFI R-PRF-01 Page 10 of 13 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC Zone 11 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC Zone 22 Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC Zone 33 Other Heating and Cooling System Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 HVAC Zone 44 Other Heating and Cooling System Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution System 4 HVAC Zone 55 Heat Pump Heating and Cooling System Heat Pump System 5 Heat Pump System 5 None - none - HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFumace 1 80 AFUE Heating Component 2 CntrlFumace 2 80 AFUE Heating Component 3 CntrlFumace 1 80 AFUE Heating Component 4 CntrlFurnace 1 80 AFUE HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 5 DuctlessMiniSplitHeatPump 1 12.3 26000 15400 18 13.5 Not Zonal Single Speed Heat Pump System 5-hers-cool Registration Number: 218-P010252246A-000-000-0000000-0000 Registration Date/Time: 2018-09-07 12:28:14 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018 CF1 R-PRF-01 Page 11 of 13 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 43_45A-Radford-17.ribd16x HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Efficiency Name System Type Number of Units EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 2 13 16 Not Zonal Single Speed Cooling Component 2-hers-cool Cooling Component 3 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 3-hers-cool Cooling Component 4 SplitAirCond 1 13.5 17 Not Zonal Single Speed Cooling Component 4-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required Cooling Component 2-hers-cool Required 350 Required Required Required Cooling Component 3-hers-cool Required 350 Required Required Required Cooling Component 4-hers-cool Required 350 Required Required Required Heat Pump System 5-hers-cool Not Required n/a Not Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 1-hers-dist Air Distribution System 2 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 2-hersAist Air Distribution System 3 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 3-hers-dist Air Distribution System 4 DuctsAttic Specified Lower Leakage 1 Target 8 Attic None Air Distribution System 4-hens-list Registration Number: 218-P010252246A-000-000-0000000-0000 Registration DateRme: 2018-09-0712:28:14 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 43_45A-Radford-17.ribd16x CF1 R-PRF-01 Page 12 of 13 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low4eakage Air Handler Air Distribution System 1-hers-0ist Required 6.0 Not Required Not Required Not Required Not Required Required Air Distribution System 2-hers-dist Required 6.0 Not Required Not Required Not Required Not Required Required Air Distribution System 3-hers-0ist Required 6.0 Not Required Not Required Not Required Not Required Required Air Distribution System 4-hers-0ist Required 6.0 Not Required Not Required Not Required Not Required Required HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.52 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.52 HVAC Fan 2-hers-fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.52 HVAC Fan 3-hers-fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.52 HVAC Fan 4-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.52 HVAC Fan 2-hers-fan Required 0.52 HVAC Fan 3-hers-fan Required 0.52 HVAC Fan 4-hers-fan Required 0.52 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 113 0.25 Default 0 Required Registration Number: 218-P010252246A-000-000-0000000-0000 Registration Date/Time: 2018-09-07 12:28:14 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-09-07 12:20:09 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 43A Calculation Date/Time: 12:18, Fri, Sep 07, 2018 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 43_45A-Radford-17.ribd16x CFI R-PRF-01 Page 13 of 13 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott Tc•rr�-��a Company: Signature Date: Scott Design and Title 24, Inc. 2018-09-0712:28:14 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Tim Scott Company: Date Signed: Scott Design and Title 24, Inc. 2018-09-07 12:28:14 Address: License: 77085 Michigan Drive NA City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Easy to Verify at CaICERTS.com Registration Number: 218-Po10252246A-000-000-0000000-0000 Registration Date/Time: 2018-09-07 12:28:14 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 HERS Provider: CaICERTS inc. Report Generated at: 2018-09-07 12:20:09