BRES2018-017578-495 CALLE TAMPICO Tity/ D 4P atba VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 9/4/2018
Permit Type/Subtype: BUILDING RESIDENTIAL/REMODEL Owner:
Application Number: BRES2018-0175 LINDSAY AND KEITH MEYER
Property Address: 78130 CALLE NORTE 78130 CALLE NORTE
APN: 770011037 LA QUINTA, CA 92253
Application Description: MEYER / 268 SF ADDT! N D [2]T VER RE R
Property Zoning:
Application Valuation: $50,000.00
Applicant: SEP 0 4 2018 Contractor:
MIGUEL TAFOYA F GALLAUDET CONSTRUCTION
74481 KING FISHER CIRCLE CITY OF LA QUINTA 54-065 AVENIDA DIAZ
LA QUINTA, CA 92253 LA QUINTA, CA 92253
DESIGN AND DEUFI. (1pRAF!�T DF?ARTMFNT
(760)413-7552
Llc. No.: 919430
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 7000} of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: 8 License No.: 919430
Date: I Contractor:
OWNER-BU1 ER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) 1, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: EXEMPT Policy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forth 'th
comply with those provisions.
Date: Applicant:
WARNING: FAILURE TO SECURE WORK COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to build'
construction, and hereby authorize representatives of this city to enter upon the
above-mentl ne property for inspection purposes.
Date: I % Signature (Applicant or Agent):
Application Number:
BRES2018-0175
Property Address:
78130 CALLE NORTE
APN:
770011037
Application Description
MEYER / 268 SF ADDTITION AND [2]TRELLIS COVER AT REAR
Property Zoning:
Application Valuation:
$50,000.00
Applicant:
MIGUEL TAFOYA
74481 KING FISHER CIRCLE
LA QUINTA, CA 92253
Owner:
LINDSAY AND KEITH MEYER
78130 CALLE NORTE
LA QUINTA, CA 92253
Contractor:
GALLAUDET CONSTRUCTION
54-065 AVENIDA DIAZ
LA QUINTA, CA 92253
(760)413-7552
LIc. No.: 919430
Date: 9/4/2018
Detail: MEYER / 268 SF ADDITION TO EXISTING 2,456 S.F. HOME, RESULTING IN A TOTAL OF 2,724 SF. ENCLOSE 136 SF PATIO UNDER EXISTING ROOF AND
CONVERT TO LIVING SPACE + 132SF. ADDITION TO BEDROOM #3.[ENGINEERED] WOOD TRELLIS AT FRONT AND REAR YARD OF DWELLING[CITY
STANDARDS] THIS PERMIT DOES NOT INCLUDE THE REPLACEMENT OF THE EXISTING HVAC EQUIPMENT OR ELECTRICAL SERVICE PANEL. SMOKE/CO
ALARMS TO BE FIELD VERIFY 2016 CALIFORNIA BUILDING CODES.
INFORMATIONFINANCIAL
DESCRIPTION ACCOUNT
CITY
AMOUNT
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400
0
$67.10
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$18.72
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ADDITION, FIRST 100 SF
101-0000-42400
0
$131.01
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$184.13
Total Paid for ADDITION: $401.02
DESCRIPTION
ACCOUNT
QTY
AMOUNT
101-0000-42600
($125.00)
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - CITY BUILDING STAFF
101-0000-42600
1
$156.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - ESGIL PLANS EXAMINER
101-0000-42600
2
$125.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - ESGIL PLANS EXAMINER
101-0000-42600
2.5
$225.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - ESGIL PLANS EXAMINER
101-0000-42600
2
$180.00
Total Paid for BLDG CITY STAFF - PER HOUR: $561.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$2.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,OOOSF
101-0000-42403
0
$156.04
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$51.49
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $207.53
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PATIO COVER, STD, OPEN
101-0000-42404
0
$104.55
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PATIO COVER, STD, OPEN PC
101-0000-42600
0
$102.99
Total Paid for PATIO COVER / COVERED PORCH / LATTICE: $207.54
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PLAN CHECK DEPOSIT - ADDITION/REMODEL
101-0000-42600
1
$125.00
Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RECORDS MANAGEMENT FEE - MAJOR
101-0000-42416
0
$20.00
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $20.00
DESCRIPTION
ACCOUNT I QTY
TECHNOLOGY ENHANCEMENT FEE + 502-0000-43611 0 $5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
�+
W uc�u
PERMIT #tT +{�
.
PLAN LOCATION: rift
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
Project Address:
APN #:
Applicant Naipe:
l 1�
iG&v
Address: q f crj--
N`� 1_ V—
v1
City, ST, Zip: �
Telephone: �19
—a S
Email: ,1.kO s� o,eI- ;I
Valuation ofProject S
. &0'%0-
Contractor Name:
New SFD Construction:
Address:
Conditioned Space SF
City, St, Zip
Garage SF
Telephone:
Patio/Porch SF
Email:
Fire Sprinklers SF
State Lic: City Bus Lic:
Arch/Eng Name:
Construction Type: Occupancy:
Address:
Grading:
City, St, Zip
Telephone:
Bedrooms: Stories: # Units:
Email:
State Lic: City Bus Lic:
11 1 . �_ . k ..►
Property Owner's Name: ���y
New Commercial / Tenant Improvements:
Address: "6177
Total Building SF
City, ST, Zip LJr `
Construction Type: Occupancy:
Telephone:
Email:
78495 CALLE TAMPICO
LA QU I NTA, CA 92253
760-777-7000
OFFICE. USE ONLY
#
Submittal
' Req'd
Rec'd
Plan Sets
Structural Calcs
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
Date: 8/24/2018
No.: 18-01088-1
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
La Quinta, CA 92253
(760)771-8515
Owner: Lindsay and Keith Meyer
Address: 78130 Calle Norte
City: La Quinta
Type: Residential Addition < 500 sq ft
Lot # Street No. Street Name
78130 Calle Norte
Comments:
a s�,
0
vI 8Ek1.I DA 0UNES
RANCN{� MIRAGgE 2
5- WDIlII'At WELLS y
V� COAiCFlEL�.t �Y
Email:
Jurisdiction: La Quinta
Tract #:
Sq. Feet APN Permit No,
268 770-011-037
R E(," . t -- 1 V P" D'
AUG Z 4 2018
CITY Or LA QUINTA
COMMUNITY DEVELOPMENT
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
Exempt
This certifies that school facility fess imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 268 S.F. or $0.00 have been paid for the property listed above and that building permits
and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Fees Paid B xe t Mi uei Tafova Check No.:
y L�/ M Telephone: 760-832-2535
Bank Name/Recipient of Certificate Funding: Exempt
By Scott L. Bailey
Superintendent
Fee Collected/ Exempted by: Rodney Slagle
Certificate Fees Due: $0.00
Original Payment(s) Rec'd: $0.00
New Payment Rec'd: $0.00
Over/Under: $0.00
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
RECORDING REQUESTED BY:
Title 365
AND WHEN RECORDED MAIL TO:
The Keith and Lindsay Meyer
1996 Trust
2950 Lansford Avenue
San Jose CA 95125
Order No.: 510-1500553-51
Escrow No.: FS895
A.P.N.: 4770.011-037-6 TRA 020-021
THIS IS TO CERTIFY THAT THIS IS A TRUE
AND CORRECT COPY OF THE TIGINAL
HEREOF � 1'
I}Y. ��1nn A'o
FOUR $ERSOHS E5cnpyy, lHC.
SPACE ABOVE THIS LINE IS FOR RECORDER'S USE
GRANT DEED
THE UNDERSIGNED GRANTOR(S) DECLARE(S)
DOCUMENTARY TRANSFER TAX IS $ 434.50
[ x ] computed on full value of property conveyed, or
[ ] computed on full value less value of liens or encumbrances remaining at time of sale.
[ ] unincorporated area [ X ] City of La Qulnta
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Charles Lester and Patricia Lester,
Trustees of The Lester Revocable Trust, dated July 8, 2010
hereby GRANT(S) to Keith G. Meyer and Lindsay A. Meyer, Trustees of the
Keith and Lindsay Meyer 1996 Trust dated May 1, 1996
the following described real property in the County of Riverside, State of California
See Exhibit "A" attached hereto and made a part hereof.
Commonly known as: 78130 Calle Norte, La Quinta, CA 92253
Dated: February 3, 2015
A notary public or other officer completing this certificate
verifies only the identity of the individual who signed the
document to which this certificate Is attached, and not the
truthfulness, accuracy, or validity of that document.
STATE OF CA FORNIA
COUNTY OF - V"5 L&A-,
On vtlon2 ' before me,
E LEICLI . ,nrc--u' , a notary public,
p_Qrsonally appeareda.nd-
S"o-j'Y L C.L &— L2,s r
who proved to me on the basis of satisfactory evidence to be the
person(s) whose name(s) is/are subscribed to the within
instrument and acknowledged to me that he/she/they executed
the same in his/her/their authorized capecity(ies), and that by
his/her/their signature(s) on the instrument the person(s), or the
entity upon behalf of which the person(s) acted, executed the
instrument.
I certify under PENALTY OF PERJURY under the laws of the
State of California that the foregoing paragraph is true and
correct.
WITNESS my hand and official seal.
The Lester Revocable Trust, dated July 8,
2010
.'�
SS. :Charles Leste , rusts
By: Patricia Lester, Trustee
ELISA A. GUERRERO
Commission 111 2072908 x
Notary Public - California Z
z a Riverside County
M Comm. Mires Jun 272018
Signature (Seal)
(This area for official notary seal)
MAIL TAX STATEMENTS AS DIRECTED ABOVE
THIS IS TO CERTIFY THAT THIS IS A TRUE
AND CORRECT COPY OF THE IGINAL
HEREOF
EXHIBIT A aY: -
Legal Description FOUR SEASONS BMW INC.
The land hereinafter referred to is situated in the City of La Quinta, County of Riverside, State of CA, and is described as
follows:
Parcel 1:
An undivided 1/54th interest in and to Lot 1 of tract no. 18767, in the City of La Quinta, County of Riverside, State of
California, as per map recorded in Book 143, Page(s) 7 and 8 thereof, of maps, in the office of the County recorder of said
County, California;
Together with that portion of the Northeast one quarter of Section 1, Township 6 South, Range 6 East, San Bernardino
Base and Meridian, described as follows:
Beginning at the most Westerly corner of said Lot 1;
Thence Southeasterly along the Westerly line of said Lot 1 on a non -tangent curve concave Northeasterly having a radius
of 223.00 feet through an angle of 04 degrees 14 minutes 19 seconds an arc length of 16.50 feet (the initial radial line
bears South 32 degrees 36 minutes 32 seconds West);
Thence South 00 degrees 00 minutes 04 seconds East, continuing along the Westerly line of said Lot 1, a distance of
113.03 feet to the Southwest corner of said Lot 1:
Thence North 41 degrees 49 minutes 11 seconds West, a distance of 175.48 feet to the Southwest corner of Lot 1 of tract
18767-2 as shown by map on file in Book 132 of maps, at Pages 53 and 54, thereof, records of Riverside County,
California;
Thence North 89 degrees 59 minutes 20 seconds East, along the Southerly line of said Lot 1 of tract 18767-2, a distance
of 89.24 feet;
Thence Southeasterly continuing along said Southerly line of on a non -tangent curve concave Northeasterly having a
radius of 223.00 feet through an angle of 04 degrees 14 minutes 19 seconds an arc length of 16.50 feet to the point of
beginning (the initial radial line bears South 36 degrees 50 minutes 51 seconds West).
Excepting therefrom Units 1 through 54, inclusive as shown upon the Condominium Plan recorded October 24, 1984 as
Instrument No. 230336 of Official Records of Riverside County, California.
Except therefrom all oil, gas, minerals and other hydrocarbon substances, lying below a depth of 500 feet, without the right
of surface entry,
Parcel 2:
Unit 11 as shown upon the Condominium Plan referred to in Parcel 1 above.
APN: 770-011-037-6
Exhibit A I Created; 02/02/2015 1 510-1500553-51
P-iO i R RED
aPROPEffrY
MANAGEMENT
The Cuacho la Nalfe s Cf minu riky
sl�ruregcuua�tt Cuur�ura�
March 1, 2018
Keith & Lindsay Meyer
78130 Calle Norte
La Quinta, CA 92253
DUNA LA QUINTA NO 1 68950 Adelina Road
HOMEOWNERS ASSOCIATION Cathedral City, CA 92234
Phone: (760) 325-9500
Fax: (760) 325-9300
Re: 78130 Calle Norte Unit Renovation
Dear Keith & Lindsay:
The Board has reviewed and approved your Architectural Request to extend the kitchen and living
room exterior wall by 6ft and reconstruct back patio per your submitted plans dated February 20,
2018. This approval will expire in twenty four (24) months from the date of this letter.
Please make sure that you and or your contractor secure all the necessary permits and follow all
guidelines prior to and during your project.
Sincerely,
Caren Carnine Oliva
Community Manager, on behalf of
Duna La Quinta Homeowners Association
Board of Directors
cc: Board of Directors
File.
�� BUILDING ENERGY ANALYSIS REPORT
PROJECT:
MEYER RESIDENCE's additi
78130 CALLE NORTE
LA QUINTA, CA 92253
Project Designer:
G-ET""(
CITY OF LA QUINT
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANC
1AT;;K2 412AV � . ,
TAFOYA DESIGN ASSOCIATES
77530 EINFIELD LN BLDG I SUITE 1111
PALM DESERT, CA 92211
760 832.2535
Report Prepared by:
Armando Chavez
TITLE 24 OF THE DESERT SERVICE
44890 Seeley
La Quinta, 92253
760 278.1840
111 M TZ
MW)dOf"
MW
E -.'IVED Job Number:
AUG OS 2013 18-TAF-001 Rc-CEIVED
JUN 12 2018
CITY OF Lg (QUINTA Date:
COMMUNITY DEVELOPMENT CITY OF LA QUINTA
6/12/2018 DESIGN AND DEVELOPMENT DEPARTMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. :X
This program developed by EnergySoft Software — www.energysoft.com.'
I TABLE OF CONTENTS
Cover Page
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: MEYER RESIDENCE Calculation DateMme: 00:25, Tue, Jun 12, 2018 Page 1 of 7
Calculation Description: Title 24 Analysis Input File Name: 001 - 78130 CALLE NORTE.dbdl6x
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
03 This building Incorporates one or more Special Features shown below
REQUIRED SPECIAL FEATURES
re following are features that must be installed as condition for meeting the modeled energy parlwmance for this Caanpu[ar analysis.
• Window ovrr}iaiiya andlorflns
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version - CF1R-09122017-934 SP1 Report Generated at: 2018-06-12 00:26:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MEYER RESIDENCE Calculation DateTme: 00:25, Tue, Jun 12, 2018
Calculation Description: Title 24 Analysis
Input File Name: 001 - 78130 CALLE NORTE.ribdl6x
CFI R-PRF-01
Page 2 of 7
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified
by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided In the building components tables below.
Bullding-level Verifications:
—None—
Cooling System Verifications:
—None —
HVAC Distribution System Verifications:
— None —
Domestic Not Water System Verifications:
— None —
BUILDING - FEATURES INFORMATION
01 02
03
04
06
06
07
Project Name Conditioned Floor Area Irtz)
Number of Dwelling
Units
Number of Bedrooms Number
of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
MEYER RESIDENCE 2580
1
2
2
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Floor Area
Avg. Ceiling
Zone Name
Zone Type
HVAC System Name
(R)
Height
Water Heating System 1
Water Heating System 2
(E) 2456
Conditioned
(E) HVAC1
2456
10
DHW Sys 1
We
(N) 124
Conditioned
(E) HVAC1
124
10
DHW Sys 1
n/a
Registration Number. Registration DatelTime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09122017-934 SP1 Report Generated at: 2018-06-12 00:26:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MEYER RESIDENCE Calculation DateMme: 00:25, Tue, Jun 12, 2018
Calculation Description: Title 24 Analysis
Input File Name: 001 - 78130 CALLE N0RTE.ribd16x
CF1 R-PRF-01
Page 3 of 7
OPAQUE SURFACES
01
02
D3
04
06
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (f,2)
Window & Door
Area (ft2)
Tilt
(deg)
Status
Verified
Existing
Condition
N - 241
(E) 2456
Def Wall'78 to'91
0
Back
241
78.29
90
Existing
No
E - 689
(E) 2456
Def Wall'76 to'91
90
Right
689
96
90
Existing
No
S - 375
(E) 2456
Def Wall'78 to'91
180
Front
375
167.976
90
Existing
No
W - 260
(E) 2456
Def Wall'78 to'91
270
Left
260
48
90
Existing
No
TO NEXT DWELLING
(E) 2456
R-13 Wall
658
0
Existing
No
TO GARAGE
(E) 2456»(N) 124
R-13 Wall
170
0
Existing
No
2456
(E) 2456
Def Roof'78 to Present
2456
Existing
No
N - 172
(N) 124
R-21 Wall
0
Back
172
90
New
n/a
E - 130
(N) 124
R-21 Wall
90
Right
138
90
New
n/a
S - 208
(N) 124
R-21 Wall
180
Front
208
a992
90
New
n/a
W-75
(N) 124
R-21 Wall
270
Left
75
90
New
We
124
(N) 124
R-38 Roof Attic
124
New
n/a
ATTIC
01
02
03
04
06
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof
Reflectance
Roof
Emlttance
Radiant
Barrier
Cool
Roof
Status
Verified Existing
Condition
Attic (E) 2456
Attic Roof(E) 2456
Ventilated
4
0.1
0,85
No
No
Existing
No
Attic (N) 124
Attic Roof(N) 124
Ventilated
4
0 1
0.85
No
No
New
No
Registration Number:
Registration Datelrime:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09122017-934 SP1
HERS Provider:
Report Generated at: 2018-06-12 00:26:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MEYER RESIDENCE Calculation DatelTime: 00:25, Tue, Jun 12, 2018
Calculation Description: Title 24 Analysis
Input File Name: 001 - 78130 CALLE NORTE.dbdl6x
CFI R-PRF-01
Page 4 of 7
FENESTRATION / GLAZING
01
02
03
04
06
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width (R)
Height (R)
Multiplier
Area (ft2)
U-factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
2466 - D
N - 241 (Back-0)
2.3
6.5
1
15.1
0.61
0.24
Insect Screen (default)
Altered
n/a
(2)3080 -5
N - 241 (Back-0)
60
8.0
1
48.0
051
0.32
Insect Screen (default)
Altered
n/a
2466 - D 2
N - 241 (Back-0)
2.3
5.5
1
15.1
0.61
0.24
Insect Screen (default)
Altered
n/a
6080 - 6
E - 689 (Right-90)
6.0
8.0
1
48.0
0.51
0.32
Insect Screen (default)
Altered
n/a
6080 - 1
E - 689 (Right-90)
6.0
8.0
1
48.0
0.51
0.32
Insect Screen (default)
Altered
n/a
16086 - 3
S - 375 (Front-180)
16.0
8.5
0.941
128.0
0.51
0,32
Insect Screen (default)
Altered
n/a
8050 - A
S - 375 (Front-180)
8.0
5.0
1
40.0
0.51
0,32
Insect Screen (default)
Altered
nla
6080-4
W - 260 (Left-270)
-
-
1
48.0
0.51
0.32
Insect Screen (default)
Altered
n/a
• BD20 - 4
N -172 (Back-0)
6.0
2.0
1
12.0
0.51Insect
Screen (default)
New
n/a
4086 - C
E - 138 (Right-90)
4.0
8.5
1
34.0
Insect Screen (default)
New
n/a
r 5040 - B
S -208 (Front-180)
4.0
8.5
0.588
20.0
i
Insect Screen (default)
New
n/a
8086 -2
S - 208 (Front-180)
80
8.5
1
680
1Insect
Screen (default)
Nev,
n/a
OVERHANGS AND FINS
01
02 03
04
06
o6
07
08 1
09
10
11
12
1 13 14
Overhang
Lett Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Sot Up
2466 - D
3
01
3
3
0
0
0
0
0
0
0
0
0
(2)3080 -5
3
0.1
3
3
0
0
0
0
0
0
0
0
0
2466 - D 2
3
0.1
3
3
0
0
0
0
0
0
0
0
0
6080 - 6
6
0.1
6
6
0
0
0
0
0
0
0
0
0
6080 - 1
6
0.1
6
6
D
0
0
0
0
0
0
0
0
16086 - 3
6
0.1
6
6
0
0
0
0
0
0
0
0
0
8050 - A
2
0.1
2
2
0
0
0
0
0
0
0
0
0
6020 - 4
2
0.1
2
2
0
0
0
0
0
0
0
0
0
4086 - C
2
0.1
2
2
0
0
0
0
0
0
0
0
0
5040 - B
10
0.1
10
10
0
0
0
0
0
0
0
0
0
8086 -2
10
L 0.1 1
10
1 10
1
0
0
0
0
0
r 0-1
0
0
0
Registration Number
Registration Daterrime:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09122017-934 SP1
HERS Provider:
Report Generated at: 2018-06-12 00:26:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CFIR-PRF-01
Project Name: MEYER RESIDENCE
Calculation Datemme: 00:25, Tue, Jun 12, 2018
Page 5 of 7
Calculation Description: Title 24 Analysis
Input File Name: 001 - 78130 CALLE NORTE.hbdl6x
OPAQUE SURFACE CONSTRUCTIONS
01 02
03
04
05
06
07
Construction Name Surface Type
Construction Type
Framing
Total Cavity
R-value
Winter Design
U-factor
Assembly Layers
Cavity/Frame: no insul /20 Top Chrd
Attic Roof(E) 2456 Attic Roofs
Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.
Roof Deck: Wood Siding/sheathing/decking
nano
0.644
Roofing: Ligru Roof (Asphall Shingle)
Ceilings (below
Inside Finish: Gypsum Board
Def Roof'78 to Present Blue)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 21
0.045
Cavity/Frame: R-9.1 /2x4
Over Ceiling Joists: R-11, 9 insul.
• Inside Finish: Gypsum Board
Def Wall'7B to'91 Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 11
0 110
• Cavity/Frame: R-11 /2x4
Exterior Finish: 3 Coal Stucco
Inside Finish: Gypsum Board
R-13 Wall Interior Walls
Wood Framed Wall
2x4 Q 16 in. O.C.
R 13
0.092
Cavity/Frame: R-13/2x4
Other Side Finish: Gypsum Board
• Cavity/Frame: no insul. /2x4 Top Chrd
Attic Roof(N) 124 Attic Roofs
Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.
Roof Deck: Wood Siding/sheathing/decking
none
0 644
Roofing: Light Roof (Asphalt Shingle)
Ceilings (below
• Inside Finish: Gypsum Board
R-38 Roof Attic attic)
Wood Framed Ceiling
2x4 @ 24 in, O.C.
R 38
0 025
Cavity/Frame: R-9.1 /2x4
Over Ceiling Joists: R-28 9 insul.
Inside Finish: Gypsum Board
R-21 Wall Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.089
• Cavity/Frame: R-21 /2x6
Exterior Finish: 3 Coat Stucco
SLAB FLOORS
01
02
03
04
05 06
07 1 08
09
Name
Zone
Area (Rz)
Perimeter
(R)
Carpeted
Edge Insul. R-value Fraction
Heated Status
Verified
Existing
Condition
24562
(E) 2456
2456
0.1
None 0.8
No Existing
No
1242
(N) 124
124
0.1
None 0.8
No New
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
n/a
Registration Number. Registration Daterrime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-09122017-934 SP1 Report Generated at: 2018-06-12 00:26:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MEYER RESIDENCE Calculation DateMme: 00:25, Tue, Jun 12, 2018
Calculation Description: Idle 24 Analysis
Input File Name: 001 - 78130 CALLE NORTE.ribdl6x
CFI R-PRF-01
Page 6 of 7
WATER HEATING SYSTEMS
01
02
03
04
06
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
(%)
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
0
Existing
No
WATER HEATERS
01
02
03
04
06
06
07
08
09
10
11
12
Name
Heater
Element
Type
Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor I Energy
Factor I Efficiency
Input Rating I
Pilot I
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand I Model
Tank Location
or Ambient
Condition
DHW Heater 1
Gas
Small Storage
1
50
0.58 EF
28,000 Btu/hr
0
nla
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
00
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution
Name
Status
Verified Existing
Condition
(E) HVAC1
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution
System 1
Existin g
No
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
06
06
07
08
09
10
Name
Type
Duct Leakage
Insulation
R-value
Supply Duct
Location
Return Duct
Location
Bypass Duct
Status
Verified Existing
Condition
HERS
Verification
Air Distribution
System 1
Ducts located in attic
(Ventilated and
Unventilated)
Existing (not specified)
Attic
Attic
None
Existing
No
n/a
IAQ (Indoor Air Quality) FANS
01
02
03
04
06
Name
IAQ CFM
IAQ Fan Type IAQ
Recovery Effectiveness(%)
HERS Verification
SFam IAQVentRpt
0
Default I0
Not Required
PROJECT NOTES
— ALL EXISTING AND PROPOSED INPUT DATA USED IN THIS REPORT WAS PROVIDED BY THE PLANS PREPARER. — LOAD CALCULATIONS AND AC SIZING EQUIPMENT SHALL BE
VERIFIED BY THE AC CONTRACTIOR PRIOR TO PLACEMENT OF ITS ORDER. LOADS DOCUMENTED IN THIS REPORT ARE SUGGUESTED LOADS ONLY. •- AC EQUIPMENTS EFFICIENCY
SHALL BE EQUAL (OR BETTER) THAN REQUIRED BY THIS REPORT. — ANY ALTERATION OR DEVIATION FROM THIS REPORT WILL BE GENERAL CONTRACTOR'S RESPONSABILITY.
Registration Number:
Registration Date/Time:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-09122017-934 SP1
HERS Provider:
Report Generated at: 2018-06-12 00:26:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MEYER RESIDENCE Calculation Datemme: 00:10, Tue, Jun 12, 2018
Calculation Description: Title 24 Analysis Input File Name: 001 - 78130 CALLE NORTE.ribdl6x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Armando Chavez
Company
TITLE 24 OF THE DESERT SERVICES INC.
Address:
44890 Seeley
92253
Documentation Author Signature:
Signature Date:
6/12/2018
CEAMERS Certification Identification (If applicable):
Phone: 760 278.1840
CFI R-PRF-01
Page 8 of 8
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professlons Code to accept responstbilrty, for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications Identified on this Certlf cote of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified an this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building perrol sppllcat
Responsible Designer Name: ResponaibleDesigner Signature: Ao�i. ,-
Company:
TAFOYA DESIGN ASSOCIATES
77530 EINFIELD LN BLDG I SUITE 101
city/StateP�LM DESERT, CA 92211
Date Signed:
License:
Phone:
760 832.2535
Registration Number. Registration Daterrime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2018-06-12 00:11:23
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
MEYER RESIDENCE'S addition
Project Address
78130 CALLS NORTE LA QUINTA
Building Type m Single Family ❑ Addition Alone
❑ Multi Family 10 Existing+ Addition/Alteration
California Energy Climate Zone Total Cond. Floor Area Addition
CA Climate Zone 15 2,580 124
Date
611212018
# of Units
1
INSULATION
Construction Type
Cavity
Area
(ft) Special Features
Status
Slab Unheated Slab -on -Grade
- no insulation
2,456 Perim = 0'
Existing
Roof Wood Framed Attic
R 21
2,456
Existing
Wall Wood Framed
R 11
1,175
Existing
Demising Wood Framed
R 13
828
Existing
Roof Wood Framed Attic
R 38
124
New
Slab Unheated Slab -on -Grade
- no insulation
124 Perim = 0'
New
Wall Wood Framed
R 21
459
New
FENESTRATION Total Area: 524 Glazing Percentage: 20.3%
Orientation Area(ft) U-Fac SHGC Overhang Sidefins
New/Altered Average U-Factor;
Exterior Shades
0.52
Status
Rear (N) 30.3 0.610
0.24 3.0
none
Bug Screen
Altered
Rear (N) 48.0 0,510
0.32 3.0
none
Bug Screen
Altered
Right (E) 96.0 0,510
a32 6.0
none
Bug Screen
Altered
Front (S) 128.0 0.510
0.32 6.0
none
Bug Screen
Altered
Front (S) 40.0 0.510
0.32 Z0
none
Bug Screen
Altered
Left (W) 48.0 0.510
0.32 none
none
Bug Screen
Altered
Rear (N) 12.0 0.510
0.32 2.0
none
Bug Screen
Altered
Right (E) 34.0 0,510
0.32 2.0
none
Bug Screen
Altered
Front (S) 88.0 0.510
0.32 10.0
none
Bug Screen
Altered
HVAC SYSTEMS
Ot . Heating Min. Eff
Cooling
Min. Eff
Thermostat
Status
1 Central Furnace 75% AFUE
HVAC DISTRIBUTION
Location Heating
Split Air Conditioner 8 0 SEER
Cooling Duct Location
Setback
Duct
R-Value
Existing
Status
(E) HVAC Ducted Ducted Attic 2.1
WATER HEATING
Qty. Type Gallons Min. Eff Distribution
Existing
Status
Erie Pro T1 by Enem ySioft User Number: 20648
ID- 18-TAF-nni
P.H. I-f of 1F
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. *Exceptions may apply.
(Ori inal08/2016)
Building Envelope Measures:
§ 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfmfft' or less when tested per
NFRC-400 or ASTM E283 or AAMAIWDMAICSA 10111.S.21A440-2011.'
§ 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
110.6-A and 110.6-B for compliance and must be caulked andlor weatherstri ed, '
§ 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed, or weather stri ed.
§ 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 11 0.8i when the installation of a cool roof is specified on the CF1 R.
§ 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043,
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceiling.'
§ 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Wall Insulation, Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19In 2x6 or U-factor of 0.074 or
§ 150.0(c): less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a
wood framed assemhlv.'
§ 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.'
§ 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following; have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration; and, when installed as pait of a heated slab floor, meet the requirements of § 110.8 .
§ 150.0(g)1: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class Il vapor retarder. This
requirement also applies to controlled ventilation crawl space for buildings complying with the exception to § 150,0(d).
§ 150.0(g)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Glass II vapor retarder must be installed on the conditioned space side of all
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
150.0 Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
§ (q)' maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)lA: Closable Doors. Masonry orfactory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at leas) six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)l C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control'
§ 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3: Certification, Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appilances. must be certified by the manufacturer to the EneEgy Commission.'
§ 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heali is higher than the cut-off temperature for supplementary heating..'
§ 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water healing recirculation loops serving multiple dwelling units must
§ 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3 c 5.
§ 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTUlhr (2 kW) must have isolation valves with hose bibbs
or other Wings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
§ 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btulhr are exempt): and pool and spa heaters.'
Building Cooling and Heating Loads. Heating and/or cooling Loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions specified in 6150.0fht2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
dr
yer vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and hoat pump systems must be equipped with liquid line filter driers If required, as specified by
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures!
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve."
§ 150 00)2C:
Water piping and cooling system line €nsulat€on, ripe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
piping for steam and h dronic heaiiq systems or hot waters stems must meet the requirements in TABLE 120.3-A.'
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.00)3B:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder,
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)l:
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation SRCC or by a listing en that is approved by he Executive Director
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this re uirement,
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)l
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be oom fessed to cause reductions in the cross -sectional area of the ducts.'
Factory -Fabricated Duct Systems, Factory -fabricated duct systems must comply with applicable requirements forduct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such toe is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements s ified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shalt vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)l 1:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0 m l land Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
press ure drop, and Iabet in re uirements of § 150.0 m 12.
2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy!- 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RAU. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced air s stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
§ 150.0(o)lA:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing. in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.'
§ 110.4(b)l:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines, or built-in or built-uo connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0
§ (p)'
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, pipinq, filters, and valves.'
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of § 110.9..
§ 110.9(e):
JAB High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the EneMy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)lA:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)l B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)l C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)l C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)l D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)l E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors.
§ 150.0(k)l F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(k).*
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)lG:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8.'
§ 150.0(k)l H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5 ; and meets all other requirements in § 150.0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5 ; and all other r uirements in 150.D k 2.
§ 150.0(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.10(k) if it
provides the functiorialily of a dimmer according to § 110.9. and complies with all other applicable requirements in § 150.0(k)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K:
_
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have Iighl sources compliant with
Reference Joint Appendix JA8, except luminaires in closets less than 70 square feel and luminaires in hallways.'
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential buiiding, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS),
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either 150.0(k)3A or with the applicable requirements in §§ 110.9. 130.0. 130.2. 130.4. 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0 k 3B or § 150.0 k 3D must comply wilh the applicable requirements in §§ 110.9, 130.0, 130.2. 130.4.140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must comply with the applicable requirements in §§ 110.9, 130.0. 130.2. 130.4.140.7, and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
a ]Icable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1,130.4. 140.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.E and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent The occupant sensors must be ca able of turning the light fully on and off from all designed paths of inigress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.10 b through § 110.10(e).
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1.
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment'
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical lane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly Indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating s stem.
§ 110.110(d):
Documentation. A copy of the construction documents or a comparable document indicating the informalion from § 110.10(b) through
110.10 c must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location: and permanently marked as "For Future Solar Electric".