Loading...
BRES2018-0265OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7006) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). () I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's 78-495 CALLE TAMPICO D VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 9/6/2018 Permit Type/Subtype: BUILDING RESIDENTIAL/ADDITION Owner: Application Number: BRES2018-0265 LISA ROSENTHAL Property Address: 48775 AVENIDA EL NIDO 6816 CHARIS CT APN: 658310018 EDEN PRAIRIE, MN 92253 Application Description ROSENTHAL / 530SF CASITA ADDITION Property Zoning: Application Valuation: $110,000.00 Applicant: (► 2018 Contractor: RYAN ARIAS SEP 0 v RON SAWYER CONSTRUCTION INC POBOX 778 78525 AVENUE 41 PALM DESERT, CA 92261 Ggy OF [AQuIN +� BERMUDA DUNES, CA 92203 DESIGN AND qFu�) riv+„gin,;+,i (760)200-0893 ----------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under rovlsians of Chapter I hereby affirm under penalty of perjury one of the following declarations: 9 {commencing with Section 70001 of Division 3 of the 9usine s VA slons ode, I have and will maintain a certificate of consent to self -insure for workers' and my License is in full force and effect. com nsation, as provided for by Section 3700 of the Labor Code, for the performance License Class: B License No.: 541336— th rk f hick this permit is issued. have and will maintain workers' compensation insurance, as required by ecti n 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: BENC ij=MARK_INSURANCE COMPANY Policy Number: CST5013163 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, hornld become subject to the workers' compensation provisions c Section 0 a the Labor Code, I shall forthwith comply with those provisions. Date: - Applicant: Llc. No.: 541336 WARNING: FAILURE TO SECURE WORKERS'COMPENSATI10N COVE GE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PEN kLTrc5AWCIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this cit to e r up e above -mentioned property for inspection purposes. Date: ' W � & Signature (Applicant or Agent): Date: 9/6/2018 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: Applicant: RYAN ARIAS POBOX 778 PALM DESERT, CA 92261 BRES2018-0265 48775 AVENIDA EL NIDO 658310018 ROSENTHAL / 530SF CASITA ADDITION $110,000.00 Owner: LISA ROSENTHAL 6816 CHARIS CT EDEN PRAIRIE, MN 92253 Contractor: RON SAWYER CONSTRUCTION INC 78525 AVENUE 41 BERMUDA DUNES, CA 92203 (760)200-0893 Llc. No.: 541336 Detail: 530 SF DETACHED CASITA ADDITION. THIS PERMIT DOES NOT INCLUDE ALTERATIONS TO ANY OTHER PORTIONS OF THE EXISTING DWELLING. 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNT CITY AMOUNT HOURLY CHARGE - ESGIL PLANS EXAMINER 101-0000-42600 2.5 $225.00 Total Paid for BLDG CITY STAFF - PER HOUR: $225.00 DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $5.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $5.00 DESCRIPTION ACCOUNT CITY AMOUNT Credit Card Fee 101-0000-43505 0 $16.02 DESCRIPTION ACCOUNT CITY AMOUNT Credit Card Fee 101-0000-43505 0 $2.25 Total Paid for Credit Card Fee: $18.27 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES/FIXTURES, ADDITIONAL 101-0000-42403 0 $106.60 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES/FIXTURES, ADDITIONAL PC 101-0000-42600 0 $26.65 Total Paid for ELECTRICAL: $185.27 DESCRIPTION ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $39.01 DESCRIPTION ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE 101-0000-42402 0 $39.01 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE PC 101-0000-42600 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN 101-0000-42402 0 $13.00 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN PC 101-0000-42600 0 $5.20 Total Paid for MECHANICAL: $148.24 DESCRIPTION ACCOUNT CITY AMOUNT PLAN CHECK DEPOSIT-ADDITION/REMODEL 101-0000-42600 1 $125.00 Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $52.00 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $52.00 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $13.00 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $26.01 I DESCRIPTION ACCOUNT CITY AMOUNT ' ROOF DRAIN 101-0000-42401 0 $26.00 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $13.00 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $7.80 Total Paid for PLUMBING FEES: $189.81 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $20.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $20.00 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $14.30 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $14.30 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($20.97) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($104.03 ) DESCRIPTION ACCOUNT QTY AMOUNT DOOR/WINDOW, NEW/ALT, FIRST 1 101-0000-42400 0 $104.03 DESCRIPTION ACCOUNT CITY AMOUNT DOOR/WINDOW, NEW/ALT, FIRST 1 PC 101-0000-42600 0 $20.97 DESCRIPTION ACCOUNT CITY AMOUNT DOOR/WINDOW, NEW/ALT, FIRST 1 PC 101-0000-42600 0 $97.62 Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $97.62 ta(2aiAra PERMIT # � s 'IlFNI,J'dr'A'SFRT— PLAN LOCATION: Project Address: 48-775 Avenida El Nido Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: 658-310-018 Addition of Attached Guest Casita Applicant Name: Ryan Arias Address: P.O. Box 778 City, ST, zip: Palm Desert, CA 92261 Telephone: (760) 346-6155 Email: Ryan@jmaarchitects.net Valuation of Project $ 110,000 Contractor Name: Tom Lathrop New SFD Construction: 530 Address: 77-530 Enfield Ln. Suite F-2 Conditioned Space 530 SF City, St, zip Palm Desert, CA 92260 Garage N/A SF Telephone: (760) 340-0044 Patio/Porch N/A SF Email: tom@lathropdevelopment.com Fire Sprinklers N/A SF State Lic: B-876328 City Bus Lic: Arch/Eng Name: James McIntosh Construction Type: V-B Occupancy: R-3 Address: P.O. BOX 778 Grading. City, St, zip Palm Desert, CA 92261 Telephone: (760) 346-6155 Bedrooms: 1 Stories: 1 # Units: Email: Jim@jmaarchitects.net State Lic: C-24267 City Bus Lic: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 CERTIFICATE OF COMPLIANCE Desert Sands Unified School District .3�•F'�b s 2� % 47950 Dune Palms Road { ra-L107 DUN' %=" MI{�p,rE G Date: 9/6/2018 La Quinta, CA 92253 }' rNps�„ LNE; L S q a No.: 18-01099-1 (760)771-8515 pl�lh7A i Owner: Lisa Rosenthal Email: Address: 48775 Avenida El Nido Jurisdiction: La Quinta City: La Quinta Tract #: Type: Detached Guest House Lot # Street No. Street Name Sq. Feet APN Permit No. 48775 Avenida El Nido 530 658-310-018 Comments: At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.79 X 530 S.F. or $2,008.70 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: C�alifornia Bank Tru fiche e w Bank Name/Recipient of Certificate By Scott L. Bailey Superintendent Fee Collected/ Exempted by: Rodney Slagle Check No.: 561061 Telephone: 760-200-0893 Funding: Residential Certificate Fees Due: $2,008.70 Original Payment(s) Rec'd: $0.00 New Payment Rec'd: $2,008.70 Over/Under: $0.00 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. EsGi I A SAFEbuilt Company DATE: 07/31/2018 ❑ APPLICANT ❑ JURIS. JURISDICTION: City of La Quinta PLAN CHECK #.: BRES2018-0265 SET: I PROJECT ADDRESS: 48775 Avenida El Nido PROJECT NAME: Attached Casita (Structural Only) ❑ The plans transmitted herewith have been corrected where necessary and substantially comply --with the jurisdiction's codes. ® The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ❑ The applicant's copy of the check list has been sent to: ® EsGil staff did not advise the applicant that the plan check has been completed. ❑ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: } Email: Mail Telephone Fax In Person ® REMARKS: Please revise red -clouded plate washer size callouts on details 10/S-2.1 and 2/S-2 on any additional copies at the jurisdiction. By: Ryan Murphy EsGil 07/23/2018 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92I23 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Plan Submittal Job Site Building Permit Number: Project Description: small casita addition Exempt: ❑ (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan 9/6/2018 48775 Avenida El Nido Owner's Namel Radelle Deis & Lisa Rosenthal Number, Street, or PO Boxi 48775 Avenida El Nido City, State, Postal Code La Quinta, CA. 92253 Owner's Phone Number c/o 760-200-0893 Owner's E-Mail Address Project Manager's Name I Ron Sawyer Project Manager's Phone Number 760-200-0893 Cr�yy. Project Managers E-mail Address ron.sa pp�� era maif.com f AEC r M EU Builder / Contractor Ron Sawyer Const S E P 0 6 Z 0 1 8 Number, Street or PO Box 78525 Ave 41 City, State, Postal Code Bermuda Dunes, CA. 92203 `.CITY tjs'-'' V OIY11k�1li,l? f 'e rq T.:i: a;i t.r��!":�n.iY Project Square Footage Approx. 530 sq ft City Approval By Renado GDuldlock-f3EC/6urrtec Waste f t 4,� Date of City Approval Materials To Be Discarded: Product Tons Trash 2.25 Not recyclable Product Tons Asphalt Brick/Block 0.00 Recyclable 0.00 Recyclable Masonry (broken) 0.00 Recyclable Cardboard 0.00 Recyclable Plaster Scrap Metal 0.65 Recyclable 0.00 Recyclable Commingled Concrete 0.00 Recyclable 2.50 Recyclable Tile (floor) 0.05 Recyclable Drywall 0.25 Recyclable Tile (roof) Wood 0.07 Recyclable 0.75 Recyclable Donated /Reuse* 0.00 Recyclable Landscape Debris 0.00 Recyclable *Describe Items Totals: Rec cle Trash 4.3 L 2.3 Projected Diversion: 65.49% I understand it Is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer Owner! Developer —/ Project Manager / Superintendent uate BUILDING ENERGY ANALYSIS REPORT Zo k &-,,- 0Z-Io5 PROJECT: Rosenthal Res 48-775 Avenida El Ni La Quinta, CA 9225 Project Designer: CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE o COMPLIANCE UA �3 74 1 %Y JMA Architecture and Engineering 73-995 El Paseo Suite 203 Palm Desert, CA 92260 (760) 346-6155 Report Prepared by: Zack Sorensen Scott Design and Title 24, Inc, 74818 Velie Way, Suite 8 Palm Desert, CA 92260 (760) 200-4780 RECEIVE JUL 20 2018 CITY OF LA QUINTA COMMUNITY DEVELOPMENT Job Number: Date: 7/11/2018 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. 110 I TABLE OF CONTENTS Cover Page Table of Contents Form CF-1 R-PRF-01-E Certificate of Compliance 2 3 Form RMS-1 Residential MPaSi irP.q Si immary ill CERTIr, TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 40D Project Name: Rosenthal Res Addition CAculation Date/Time: 08:23, Wed, Jul 11, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpB854.tmp.xml GENERAL INFORMATION 01 Project Name Rosenthal Res Addition 02 Calculation Description Title 24 Analysis 03 Project Location 48-775 Avenida El Nido 04 City La Quinta 06 Zip Code 92253 08 Climate Zone CZ15 10 Building Type Single Family 12 Project Scope Addition and/or Alteration 14 Total Cond. Floor Area (ftZ) 3985 16 Slab Area (ftZ) 3985 18 Addition Cond. Floor Area (ftZ) 530 20 Addition Slab Area (ftZ) 530 CF 'RF-01 Page 1 of 10 05 Standards Version Compliance 2017 07 Compliance Manager Version BEMCmpMgr 2016.3.0 (1016 SP2) 09 Software Version EnergyPro 7.2 11 Front Orientation (deg/Cardinal) 330 13 Number of Dwelling Units 1 15 Number of Zones 2 17 Number of Stories 1 19 Natural Gas Available F22. 21 Glazing Percentage (%)% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 04 Energy Use (kTDV/ftZ-yr) Space Heating Space Cooling IAQ Ventilation Water Heating Photovoltaic Offset Compliance Energy Total ENERGY USE SUMMARY 05 06 Standard Design ProTposed Design 5.46 157.78 0.00 5.16 168.40 4.93 155.73 0.00 4.90 0.00 165.56 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Insulation below roof deck • Window overhangs and/or fins 07 Compliance Margin 0.53 2.05 0.00 0.26 0.00 2.84 08 Percent Improvement 9.7% 1.3% 0.0% 5.0% 1.7% Registration Number: 218-Po10197619A-000-000-0000000-0000 Registration Date/Time: 2018-07-11 08:42:47 HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance CaICERTS inc. Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-07-11 08:25:10 CERTIf TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE' -IOD CF j RF-01 Project Dame: Rosenthal Res Addition Calculation Date/Time: 08:23, Wed, Jul 11, 2018 Page 2 of 10 Calculation Description: Title 24 Analysis Input File Name: tmpB854.tmp.xml HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) Cooling System Verifications: • Minimum Airflow • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • -- None -- BUILDING - FEATURES INFORMATION 01 02 03 Number of Dwelling Conditioned Floor Area (ftZ) Units 3985 1 Project Name Rosenthal Res Addition ZONE INFORMATION 01 Zone Name Ex Residence Bedroom Addition 02 1 03 04 05 Number of Bedrooms I Number of Zones 3 2 Zone Type HVAC System Name Conditioned Existing HVAC1 Conditioned HVAC Casita2 04 05 Zone Floor Area Avg. Ceiling (ftZ) Height 3455 9 530 9 06 Number of Ventilation Cooling Systems 0 06 Water Heating System 1 DHW Sys 1 DHW Sys 3 07 Number of Water Heating Systems 2 07 Water Heating System 2 n/a n/a Registration Number: 218-P010197619A-000-000-0000000-0000 Registration DateMme: 2018-07-11 08:42:47 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-07-11 08:25:10 CERTI( TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE40D ProjectWame: Rosenthal Res Addition Calculation Date/Time: 08:23, Wed, Jul 11, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpB854.tmp.xml CF 'RF-01 Page 3 of 10 OPAQUE SURFACES 01 02 03 04 06 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) Status Verified Existing Condition 60d Wall Ex Residence R-19 Wall (W.19.2x6.16) 60 Left 770 79.1 1 90 Existing No 150d Wall Ex Residence R-19 Wall (W.19.2x6.16) 150 Back 940 174.4 90 Existing No 240d Wall Ex Residence R-19 Wall (W.19.2x6.16) 240 Right 770 130.4 90 Existing No 330d Wall Ex Residence R-19 Wall (W.19.2x6.16) 330 Front 940 346.2 90 Existing No Roof Ex Residence Default prior To 1978 3455 Existing No 60d Wall 2 Bedroom Addition R-21 Wall 60 Left 162 70.5 90 New n/a 150d Wall 2 Bedroom Addition R-21 Wall 150 Back 375 56.8 90 New n/a 240d Wall 2 Bedroom Addition R-21 Wall 240 Right 148 15.4 90 New n/a 330d Wall 2 Bedroom Addition R-21 Wall 330 Front 270 63.4 90 New n/a Interior Surface Bedroom Addition»Ex Residence R-13 Wall 150 0 New n/a Roof 2 Bedroom Addition R-38 Roof Attic R19 530 New n/a ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Ex Residence Attic RoofEx Residence Ventilated 0 0.1 0.85 No No Existing No Attic Bedroom Addition Attic RoofBedroom Addition Ventilated 3 0.1 10.85 1Yes No New No Registration Number: 218-P010197619A-000-000-0000000-0000 Registration Dateffime: 2018-07-11 08:42:47 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-07-11 08:25:10 CERTI( TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE ' iOD Project Mime: Rosenthal Res Addition Calculation Date/Time: 08:23, Wed, Jul 11, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpB854.tmp.xml CF JRF-01 Page 4 of 10 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft) U-factor SHGC Exterior Shading Status Verified Existing Condition 1.3 x 6.7 60d Wall (Left-60) -- 1 8.7 0.71 1 0.60 Insect Screen (default) Existing No 8 x 5.8 60d Wall (Left-60) - 1 46.4 0.71 0.60 Insect Screen (default) Existing No 3 x 8 60d Wall (Left-60) -- - 1 24.0 0.71 0.60 Insect Screen (default) Existing No 8 x 5.8 2 150d Wall (Back-150) - -- 1 46.4 0.71 0.60 Insect Screen (default) Existing No 1 x 6 150d Wall (Back-150) -- 1 6.0 0.71 0.60 Insect Screen (default) Existing No 1 x 6 2 150d Wall (Back-150) - - 1 6.0 0.71 0.60 Insect Screen (default) Existing No 8 x 5.8 3 150d Wall (Back-150) -- - 1 46.4 0.71 0.60 Insect Screen (default) Existing No 4.3 x 5.3 150d Wall (Back-150) - - 1 22.8 0.71 0.60 Insect Screen (default) Existing No 6 x 5 240d Wall (Right-240) ----- 1 30.0 0.71 0.60 Insect Screen (default) Existing No 2.8 x 3.3 240d Wall (Right-240) - - 1 9.2 0.71 0.60 Insect Screen (default) Existing No 2.8 x 8 240d Wall (Right-240) - ---- 1 22.4 0.71 0.60 Insect Screen (default) Existing No 2.8 x 8 2 240d Wall (Right-240) - 1 22.4 0.71 0.60 Insect Screen (default) Existing No 5.8 x 8 240d Wall (Right-240) -- -- 1 46.4 0.71 0.60 Insect Screen (default) Existing No 3 x 3.4 330d Wall (Front-330) ---- 1 10.2 0.71 0.60 Insect Screen (default) Existing No 12 x 8 330d Wall (Front-330) - -- 1 96.0 0.71 0.60 Insect Screen (default) Existing No 2.8 x 8 3 330d Wall (Front-330) 1 22.4 0.71 0.60 Insect Screen (default) Existing No 7.8 x 8 330d Wall (Front-330) - - 1 62.4 0.71 0.60 Insect Screen (default) Existing No 5.8 x 8 2 330d Wall (Front-330) - 1 46.4 0.71 0.60 Insect Screen (default) Existing No 7.8 x 8 2 330d Wall (Front-330) -- - 1 62.4 0.71 0.60 Insect Screen (default) Existing No 2.8 x 8 4 330d Wall (Front-330) - --- 1 22.4 0.71 0.60 Insect Screen (default) Existing No 4 x 6 330d Wall (Front-330) ---- 1 24.0 0.71 0.60 Insect Screen (default) Existing No 3 60d Wall 2 (Left-60) 6.0 9.0 1 54.0 1 0.30 0.20 Insect Screen (default) New n/a M 60d Wall 2 (Left-60) 1.0 6.0 1 6.0 0.30 0.20 Insect Screen (default) New n/a I 60d Wall 2 (Left-60) 3.5 3.0 1 10.5 0.30 0.20 Insect Screen (default) New n/a E 150d Wall 2 (Back-150) ---- 1 15.8 0.30 0.20 Insect Screen (default) New n/a F 150d Wall 2 (Back-150) 1 27.0 0.30 0.20 Insect Screen (default) New n/a G 150d Wall 2 (Back-150) - - -- 1 9.0 1 0.30 0.20 Insect Screen (default) I New n/a H 150d Wall 2 (Back-150) - -- 1 5.0 1 0.30 1 0.20 Insect Screen (default) I New n/a Registration Number: 218-P010197619A-000-000-0000000-0000 Registration Date/Time: 2018-07-11 08:42:47 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-07-11 08:25:10 CERTI� TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project (Tame: Rosenthal Res Addition Calculation Description: Title 24 Analysis HOD Calculation Date/Time: 08:23, Wed, Jul 11, 2018 Input File Name: tmpB854.tmp.xml CF IRF-01 Page 5 of 10 B 240d Wall 2 (Right-240) — -- 1 5.6 0.30 0.20 Insect Screen (default) New n/a C 240d Wall 2 (Right-240) — 1 5.6 0.30 0.20 Insect Screen (default) New n/a D 240d Wall 2 (Right-240) -- -- 1 4.2 0.30 0.20 Insect Screen (default) New n/a 2 330d Wall 2 (Front-330) -- -- 1 20.0 0.30 0.20 Insect Screen (default) New n/a L 330d Wall 2 (Front-330) --•- -- 1 33.0 0.30 0.20 Insect Screen (default) New n/a K 330d Wall 2 (Front-330) — 1 6.8 0.30 0.20 Insect Screen (default) New n/a J 330d Wall 2 (Front-330) — -- 1 3.6 0.30 0.20 Insect Screen (default) New n/a OPAQUE DOORS 01 02 03 04 05 06 Name Side of Building Area (ft) U-factor Status Verified Existing Condition 6 x 7.8 Entry Door 150d Wall 46.8 0.50 Existing No OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 1 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 3 6 0.1 6 6 0 0 0 0 0 0 0 0 0 M 4 0.1 4 4 0 0 0 0 0 0 0 0 0 1 4 0.1 4 4 0 1 0 0 0 0 0 1 0 0 0 Registration Number: 218-P010197619A-000-000-0000000-0000 Registration Date/Time: 2018-07-11 08:42:47 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-07-11 08:25:10 CERTIr, TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE' Project Name: Rosenthal Res Addition HOD CF CTculation Date/Time: 08:23, Wed, 7RF-01 Jul 11, 2018 Calculation Description: Title 24 Analysis Page 6 of 10 Input File Name: tmpB854.tmp.xml OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Construction Name Surface Type Construction Type Framin Total Cavity Winter Design 9 R-value U-factor Assembly Layers Attic RoofEx Residence Attic Roofs Wood Framed Ceiling 2x4 Top Chord Truss @ 24 • Cavity / Frame: no insul. / 2x4 Top Chrd Roof Deck: Wood Sidinglsheathing/decking 'ofOCof none 0.644 Rooting: Light Roof (Asphalt Shingle) Ceilings (below Inside Finish: Gypsum Board Default prior To 1978 attic) Wood Framed Ceilin 9 2x4 @ 16 in. O.C. R 11 Cavity/Frame: R-9.1 /2x4 0.083 Over Ceiling Joists: R-1.9 insul. • Inside Finish: Gypsum Board R-19 Wall (W. 1 9.2x6.16) Exterior Walls Wood Framed Wall 2x6 16 in. O.C. R 19 in 5-1/2 in. �o CavitylFrame: R-19 in 5-1/2 in. (R-18) /2x6 cavity (R-18) 0.074 Exterior Finish: 3 Coat Stucco • Around Roof Joists: R-6.0 insul. Attic RoofBedroom Addition Attic Roofs Wood Framed Ceiling 2x4 Top Chord Roof Truss @ 24 • Cavity/Frame: R-13.0/2x4 Top Chrd Roof Deck: Wood Sidinglsheathing/decking 'off R 19 0.059 Roofing: Light Roof (Asphalt Shingle) Ceilings (below Finish: Gypsum Board R-38 Roof Attic R19 attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 =Fltty/Frame: R-9.1 /2x4 Ceiling Joists: R-9.9 insul. Finish: Gypsum Board R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 /Frame: R-21 /2x6 0.069 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board R-13 Wall Interior Walls Wood Framed Wall 2x4 16 in. O.C. �° R 13 Cavity/Frame: R-13/2x4 0.092 Other Side Finish: Gypsum Board SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name LEx Zone Area ftz ( ) Perimeter (ft) Carpeted Verified Existing Slab -on -Grade Residence Edge Insul. R-value Fraction Heated Status Condition Slab -on -Grade 2 Bedroom Addition 3455 530 0.1 132 None 0.8 No Existing No None 0.8 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 Quality Insulation Installation (QII) 02 03 04 Quality Installation of Spray Foam Insulation Building Envelope Air Leakage Required Not Required Not Required CFM50 n/a Registration Number: 218-Po10197619A-000-000-0000000-0000 Registration Dateffime: 2018-07-11 08:42:47 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 HERS Provider: CaICERTS inc. Report Generated at: 2018-07-11 08:25:10 CERTIr TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE' !iOD Project 17ame: Rosenthal Res Addition Calculation Date/Time: 08:23, Wed, Jul 11, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpB854.tmp.xml WATER HEATING SYSTEMS 01 02 03 04 Name System Type Distribution Type Water Heater DHW Sys 1 DHW Standard DHW Heater 1 DHW Sys 3 DHW Standard DHW Heater 3 WATER HEATERS 01 02 03 04 06 06 07 08 Heater Input Rating / Tank Tank Uniform Energy Pilot Insulation Element Number Volume Factor / Energy Thermal R-value Name Type Tank Type of Units (gal) Factor I Efficiency Efficiency (Int/Ext) DHW Heater 1 Gas Small Storage 1 50 0.61 EF 40,000 Btu/hr 0 DHW Heater 3 Gas Small Instantaneous 1 0 0.99 EF 199,900 Btu/hr 0 SPACE CONDITIONING SYSTEMS 01 02 SC Sys Name System Type Existing HVAC1 Other Heating and Cooling System HVAC Casita2 Other Heating and Cooling System HVAC - HEATING UNIT TYPES 01 Name Heating Component 1 Heating Component 2 03 04 Heating Unit Name Cooling Unit Name Heating Component 1 Cooling Component 1 Heating Component 2 Cooling Component 2 02 System Type CntrlFurnace CntrlFurnace CF >RF-01 Page 7of10 05 Number of Heaters 1 1 06 07 08 Solar Fraction N Status Verified Existing Condition 0 Existing No 0 New No 09 Standby Loss / Firs' Recovery Ra Eff i Flov 05 Fan Name HVAC Fan 1 HVAC Fan 2 n/a I r n/a I r 10 11 12 Hour ing / Rate NEEA Heat Pump Brand / Model Tank Location or Ambient Condition /a n/a n/a /a n/a n/a 06 Distributic Name Air Distributi System 1 Air Distributi System 2 03 Number of Units 1 1 07 08 n Status Verified Existing Condition )n Existing No )n New No 04 Efficiency 80 AFUE 80 AFUE Registration Number: 218-Po10197619A-000-000-0000000-0000 Registration DateMme: 2018-07-11 08:42:47 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-07-11 08:25:10 CERTI( TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE' 40D Project Name: Rosenthal Res Addition Circulation Date/Time: 08:23, Wed, Jul 11, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpB854.tmp.xml CF )RF-01 Page 8 of 10 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Efficiency Name System Type Number of Units EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 NoCooling 1 n/a n/a n/a n/a n/a Cooling Component 2 SplitAirCond 1 11.7 13.1 Not Zonal Single Speed Cooling Component 2-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 2-hers-cool Not Required --.. Not Required Not Required Not Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R-value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Air Distribution System 1 (Ventilated and Sealed and tested 8.0 Attic Attic None I New No I System Unventilated) 1-hers-dist Air Distribution Ducts located in attic Air Distribution System 2 (Ventilated and Sealed and tested 8.0 Attic Attic None New No System Unventilated) 2-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 2-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a HVAC - FAN SYSTEMS & HERS VERIFICATION 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 Required Registration Number: 218-P010197619A-000-000-0000000-0000 Registration Date/Time: 2018-07-11 08:42:47 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-07-11 08:25:10 CERTI( TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE f 1013 Project Name: Rosenthal Res Addition Calculation Date/Time: 08:23, Wed, Jul 11, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpB854.tmp.xml CF RF-01 Page 9 of 10 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 0.25 Default 0 Not Required Registration Number: 218-P010197619A-000-000-0000000-0000 Registration DateMme: 2018-07-11 08:42:47 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-07-11 08:25:10 CERTIF TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 1 iOD Project Name: Rosenthal Res Addition Calculation Date/Time: 08:23, Wed, Jul 11, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpB854.tmp.xml CF AF-01 Page 10 of 10 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott 7;r/-5'AZr Company: Signature Date: Scott Design and Title 24, Inc. 2018-07-11 08:42:47 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: ;z;el��� Tim Scott Company: Date Signed: Scott Design and Title 24, Inc. 2018-07-11 08:42:47 Address: License: 77085 Michigan Drive N/A City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 218-P010197619A-000-000-0000000-0000 Registration Date/Time: 2018-07-11 08:42:47 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Q., Easy to Verify at CaICERTS.com HERS Provider: CaICERTS inc. Report Generated at: 2018-07-11 08:25:10 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Res ' Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family [0 Existing+ Addition/Alteration 112018 Project Address 48-775 Avenida El Nido La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,985 Addition 530 YDateRosenthal of Units 1 INSULATION Construction Type Cavity Area ft Special Features Status Roof Wood Framed Attic R 11 3,455 Existing Wall Wood Framed R 19 2,690 Existing Door Opaque Door no insulation 47 Existing Slab Unheated Slab -on -Grade no insulation 3,455 Perim = 0' Existing Roof Wood Framed Attic R 19 530 Add=R-19.0 New Wall Wood Framed R 21 749 New Slab Unheated Slab -on -Grade - no insulation 530 Perim = 132' New Demising Wood Framed R 13 150 Existing FENESTRATION Orientation Area ft2 Total Area: 889 Glazing Percentage: 22.3 % U-Fac SHGC Overhang Sidefins New/Altered Average U-Factor: 0.30 Exterior Shades Status Left (NE) 79.1 0.710 0.60 none none Bug Screen Existing Rear (SE) 127.6 0.710 0.60 none none Bug Screen Existing Right (SW) 130.4 0.710 0.60 none none Bug Screen Existing Front (NW) 346.2 0.710 0.60 none none Bug Screen Existing Left (NE) 54.0 0.300 0.20 6.0 none Bug Screen Existing Left (NE) 16.5 0.300 0.20 4.0 none Bug Screen New Rear (SE) 56.8 0.300 0.20 none none Bug Screen New Right (SW) 15.4 0.300 0.20 none none Bug Screen New Front (NW) 63.4 0.300 0.20 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.1 SEER Setback New HVAC DISTRIBUTION Location Heating Coolinu Duct Location Duct R-Value Status HVAC Casila Ducted Ducted Attic 6.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Instantaneous Gas 0 0.99 Standard New Ener Pro 7.2 b v Ener Soft UserNumber.- 6712 ID: Pa e 13 of 21 ■ �} , 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. *Exceptions may apply. tOrialnal OW20161 Building Envelope Measures: § 110.6(a)l: Air Leakage, Manufactured fenestration, exterior doors, and exterior pet doors mu NFRC-400 orASTM E283orAAMA1WDMAICSA 1011I.S.2JA440-2011,' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors ar 110,6-A and 110.6-B for com liance and must be caulked andfor weatherstri -d. § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope t asketed, or weather stripp ed. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must r § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be ins § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emltt material must meet the re uiremen!s of 110.8 i when the instaliatlon of a cool ro[ § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be cf Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceilin § 150.0(a): Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteratic insulation using adhesive or mechanical fasteners. The attic access must be gasket direct contact with a continuous roof or ceiling which is sealed to limit infiltration and to placing insulation either above or below the roof deck or on to of a d all ceilPni § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required di § 150.0(c): st limit air leakage to 0.3 cfm/ft2 or less when tested per 10-111(a). d solar heat gain coefficient (SHGC) values from TABLES iat are potential sources of air leakage must be caulked, neet Standards for Insulating Material. ulated per the requirements of § 110.8(g). once and aged solar reflectance 'values the roofing d is s ecified on the CF1 R. ;rtified to the Department of Consumer Affairs. g; or the weighted average U-factor must not exceed 0.043. m. Attic access doors must have permanently attached ed to prevent air leakage. Insulation must be installed in exfiltration as specified in § 110.7, including but not limited �nsity for the labeled R-value. Yvan msuiation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or wood framed assemhiv' less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation In raised wood framed floor or 0.037 maximum U-factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a healed slab floor, meet the re uirements of § 110.8 . § 150.0(g)l: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This re uirement also a P PIies to controlled ventilation crawls ace for buildings complyin2 with the exception to J 150.Q d V§ 150.0(g)2: apor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all sulation in all exterior walls, vented attics, and unvented attics with airmpermeable Insulation. § 150.0(q): Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58; or the weighted averse Ll-factor of all fenestration must not exceed 0,58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)1 B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches In area and is eguipped with a readily accessible o erable, and fight-fiffingi damper or combuslion-air control device.' § 150.0(e)l C: Flue Damper, Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the buildin , are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated a liances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for cam ression heating is higher than the cut-off temperature for supplementary heating.' § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3 c 5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittin s on both cold water and hot water lines of water heating systems to allow for water tank flushf i when the valves are closed. § 110.5: Pilot Lights, Continuously burning pilot lights are prohibited for natural gas: fan -type central fumaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt and pool and spa heaters. Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)1: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditlons specified in 6 150.0ih17 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150 00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution piping for steam and h dronle heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)36� Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1; 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 156.6(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Cor oratlon SRCC. or by a listing age n cthat is a pproved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the cuslomer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1. (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such toe Is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all o enin s to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0(m)11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of § 150.0(m)12. OM 2016 Low -Rise Residential Mandatory Measures Summary I Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy15 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole- uilding ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.* § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar hearing. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pum s to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. § 150,0(p): Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of 110.9.' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fanspeed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1 C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of§ 150.0(I�).' Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JAB compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5(f); and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 ; and all other requirements in § 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmer according to § 110.9, and complies with all other a ![cable requirements in § 150.0(k)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS). Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0 k 3A or with the applicable requirements in &§ 110.9, 130.0,130.2, 130.4,140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B'or § 150A k 3D must comply with the applicable re uirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting, Outdoor Iighting for residential parking lots and residential carports with a total of eight or more vehicles per site must cam 1 with the applicable requirements in §§ 110.9 130.0, 130.2,130.4, 140.7 and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4. 14.0.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1� application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.10(b) through § 110.10(e). § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d) Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.* Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d). Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 110.10 c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel, The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanentIX marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Rosenthal Res Date 7/11/2018 System Name Existing HVAC Floor Area 3,455 ENGINEERING CHECKS SYSTEM LOAD Number of Systems COIL CFM Total Room Loads 3,766 Return Vented Lighting Return Air Ducts Return Fan Ventilation o Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 72,150 3,890 1,087 47,139 Total Output (Btuh) 0 Output Btuh/s ft 4,165 2,317 Cooling System 0 0 Output per System 0 0 0 0 Total Output Btuh 0 4,165 80,480 3,890 0 Total Output Tons 2,317 Total Output Btuh/s ft) Total Output s ft/Ton 51,773 Air System CFM per System HVAC EQUIPMENT SELECTION Airflow cfm Airflow cfm/s ft) Airflow cfm/Ton) Outside Air % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Outside Air cfm/s ft 1 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air 0 cfm 67 OF 67 OF 110 OF Heating Coil i UTI 109 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF Air-4r 0 cfm 77/63OF 77/63OF 55/54OF HJOutside J Cooling Coil T-1 4 I . L 57 155 OF 48.5 % ROOM 75/62OF EnergyPro 7.2 by EnergySoft User Number: 6712 ID: +' .; 18 of 21 HV��.SYSTEM HE AND COOLING LOADS SUMMARY Proje Rosenthal Res Date system Name 7/11/2018 HVAC Casita Floor Area ENGINEERING CHECKS 530 SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Out ut per 5 stem 66,000 Total Room Loads 399 8,258 597 296 10,831 Total Ou ut Btuh 66,000 Return Vented Lighting 0 Output Btuhls ft 124.5 Return Air Ducts 477 532 CoolingSystem Return Fan 0 0 Out ut per System 24,800 Ventilation 0 0 � o 0 Total Output Btuh 24,800 Supply Fan 0 0 Total Out ut Tons 2.1 Supply Air Ducts 477 532 Total Out ut 8tuhls ft 46.8 Total Out ut s ftlTon 256.5 TOTAL SYSTEM LOAD 9,211 597 Air S stem 11,895 CFM per System 800 HVAC E[UIPMENT SELECTION Airflow (cfml 800 Carrier24ANB724 18,833 2,116 66,000 Airflow cfrnlsgft 1.51 AfrflOw cfm/Ton 387.1 Outside Air °I° 0.0 °I° Total Adjusted System Output 18,833 2,116 9 66,000 Outside Air cfmis ft 0.00 (Adjusted For Peak Design canditfons) Note: values above given at ARI conditions I TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Tern Deratures at Time of Heatin Peak 26 IF 69 OF 105 OF 105 OF OutsideAir �I I................................... ............................. . . . 0 cfm Heating Coil Supply Fan 800 cfm 104 IF 69 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of C, 112/78IF 76/62°F 55/54°F 55/54 OF Outside Air Q 0 cfm Cooling Coil Supply Fan 800 cfm 76 / 62 IF EnargyPro 7.2 by EnergySoR User Number. 6712 Pea ROOM 70 OF 56/54°F 46.9 % ROOM 75/62°F ID. Page 19 of 21 ZONE LOAD SUMMARY Project Name Rosenthal Res Date 711112018 System Name Existing HVAC Floor Area 3,455 ZONE LOAD SUMMARY ZONAL SYSTEM —CFM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible Ex Residence 1.0 0 Aug 3 PM 3,766 72,150 3,890 1,087 47,139 TOTALS 0 0 01 01 Aug 3 PM 72,150 f 3,890 47,139 (BLOCK LOAD) EnergyPro 7.2 by EnergySoft User Number- 6712 ID Page 20 of 21 ZONE LOAD SUMMARY Project Name Rosenthal Res Date 711112018 System Name HVAC Casita Floor Area 530 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heatina OA CFM Peak Hr CFM Sensible Latent CFM Sensible Bedroom Addition 1.0 0 Aug 3 PM 1 399 8,258 597 296 10,831 TOTALS 0 0 0 0 Aug 3 PM 8,258 597 10,831 (BLOCK LOAD) EnergyPro 7.2 by LnergySaft User Number: 6712 ID: Page 21 of 21