BRES2018-0265OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7006) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
() I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's
78-495 CALLE TAMPICO D VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 9/6/2018
Permit Type/Subtype: BUILDING RESIDENTIAL/ADDITION Owner:
Application Number: BRES2018-0265 LISA ROSENTHAL
Property Address: 48775 AVENIDA EL NIDO 6816 CHARIS CT
APN: 658310018 EDEN PRAIRIE, MN 92253
Application Description ROSENTHAL / 530SF CASITA ADDITION
Property Zoning:
Application Valuation: $110,000.00
Applicant: (► 2018 Contractor:
RYAN ARIAS SEP 0 v RON SAWYER CONSTRUCTION INC
POBOX 778 78525 AVENUE 41
PALM DESERT, CA 92261 Ggy OF [AQuIN +� BERMUDA DUNES, CA 92203
DESIGN AND qFu�) riv+„gin,;+,i
(760)200-0893
-----------------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under rovlsians of Chapter I hereby affirm under penalty of perjury one of the following declarations:
9 {commencing with Section 70001 of Division 3 of the 9usine s VA
slons ode, I have and will maintain a certificate of consent to self -insure for workers'
and my License is in full force and effect. com nsation, as provided for by Section 3700 of the Labor Code, for the performance
License Class: B License No.: 541336— th rk f hick this permit is issued.
have and will maintain workers' compensation insurance, as required by
ecti n 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: BENC ij=MARK_INSURANCE COMPANY Policy Number: CST5013163
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, hornld become subject to the
workers' compensation provisions c Section 0 a the Labor Code, I shall forthwith
comply with those provisions.
Date: - Applicant:
Llc. No.: 541336
WARNING: FAILURE TO SECURE WORKERS'COMPENSATI10N COVE GE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PEN kLTrc5AWCIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this cit to e r up e
above -mentioned property for inspection purposes.
Date: ' W � & Signature (Applicant or Agent):
Date: 9/6/2018
Application Number:
Property Address:
APN:
Application Description
Property Zoning:
Application Valuation:
Applicant:
RYAN ARIAS
POBOX 778
PALM DESERT, CA 92261
BRES2018-0265
48775 AVENIDA EL NIDO
658310018
ROSENTHAL / 530SF CASITA ADDITION
$110,000.00
Owner:
LISA ROSENTHAL
6816 CHARIS CT
EDEN PRAIRIE, MN 92253
Contractor:
RON SAWYER CONSTRUCTION INC
78525 AVENUE 41
BERMUDA DUNES, CA 92203
(760)200-0893
Llc. No.: 541336
Detail: 530 SF DETACHED CASITA ADDITION. THIS PERMIT DOES NOT INCLUDE ALTERATIONS TO ANY OTHER PORTIONS OF THE EXISTING DWELLING. 2016
CALIFORNIA BUILDING CODES.
DESCRIPTION
ACCOUNT CITY
AMOUNT
HOURLY CHARGE - ESGIL PLANS EXAMINER
101-0000-42600 2.5
$225.00
Total Paid for BLDG CITY STAFF - PER HOUR:
$225.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$5.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA:
$5.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
Credit Card Fee
101-0000-43505
0
$16.02
DESCRIPTION
ACCOUNT
CITY
AMOUNT
Credit Card Fee
101-0000-43505
0
$2.25
Total Paid for Credit Card Fee: $18.27
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20
101-0000-42403
0
$26.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20 PC
101-0000-42600
0
$26.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES/FIXTURES, ADDITIONAL
101-0000-42403
0
$106.60
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES/FIXTURES, ADDITIONAL PC
101-0000-42600
0
$26.65
Total Paid for ELECTRICAL: $185.27
DESCRIPTION
ACCOUNT
CITY
AMOUNT
CONDENSER/COMPRESSOR
101-0000-42402
0
$39.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
CONDENSER/COMPRESSOR PC
101-0000-42600
0
$26.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FURNACE
101-0000-42402
0
$39.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FURNACE PC
101-0000-42600
0
$26.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN
101-0000-42402
0
$13.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN PC
101-0000-42600
0
$5.20
Total Paid for MECHANICAL: $148.24
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PLAN CHECK DEPOSIT-ADDITION/REMODEL
101-0000-42600
1
$125.00
Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$52.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$52.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS
101-0000-42401
0
$13.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS PC
101-0000-42600
0
$26.01
I DESCRIPTION
ACCOUNT
CITY
AMOUNT
' ROOF DRAIN
101-0000-42401
0
$26.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER HEATER/VENT
101-0000-42401
0
$13.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER HEATER/VENT PC
101-0000-42600
0
$7.80
Total Paid for PLUMBING FEES: $189.81
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RECORDS MANAGEMENT FEE - MAJOR
101-0000-42416
0
$20.00
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $20.00
DESCRIPTION ACCOUNT
CITY
AMOUNT
SMI - RESIDENTIAL 101-0000-20308
0
$14.30
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $14.30
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($20.97)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($104.03 )
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DOOR/WINDOW, NEW/ALT, FIRST 1
101-0000-42400
0
$104.03
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DOOR/WINDOW, NEW/ALT, FIRST 1 PC
101-0000-42600
0
$20.97
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DOOR/WINDOW, NEW/ALT, FIRST 1 PC
101-0000-42600
0
$97.62
Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $97.62
ta(2aiAra
PERMIT # � s 'IlFNI,J'dr'A'SFRT—
PLAN LOCATION:
Project Address: 48-775 Avenida El Nido
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #: 658-310-018
Addition of Attached Guest Casita
Applicant Name: Ryan Arias
Address: P.O. Box 778
City, ST, zip: Palm Desert, CA 92261
Telephone: (760) 346-6155
Email: Ryan@jmaarchitects.net
Valuation of Project $ 110,000
Contractor Name: Tom Lathrop
New SFD Construction: 530
Address: 77-530 Enfield Ln. Suite F-2
Conditioned Space 530 SF
City, St, zip Palm Desert, CA 92260
Garage N/A SF
Telephone: (760) 340-0044
Patio/Porch N/A SF
Email: tom@lathropdevelopment.com
Fire Sprinklers N/A SF
State Lic: B-876328 City Bus Lic:
Arch/Eng Name: James McIntosh
Construction Type: V-B Occupancy: R-3
Address: P.O. BOX 778
Grading.
City, St, zip Palm Desert, CA 92261
Telephone: (760) 346-6155
Bedrooms: 1 Stories: 1 # Units:
Email: Jim@jmaarchitects.net
State Lic: C-24267 City Bus Lic:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
.3�•F'�b s
2� %
47950 Dune Palms Road
{
ra-L107 DUN'
%=" MI{�p,rE G
Date: 9/6/2018 La Quinta, CA 92253
}' rNps�„ LNE; L S q
a
No.: 18-01099-1 (760)771-8515
pl�lh7A i
Owner: Lisa Rosenthal Email:
Address: 48775 Avenida El Nido Jurisdiction: La Quinta
City: La Quinta Tract #:
Type: Detached Guest House
Lot # Street No. Street Name Sq. Feet APN Permit No.
48775 Avenida El Nido 530 658-310-018
Comments:
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fess imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $3.79 X 530 S.F. or $2,008.70 have been paid for the property listed above and that building
permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Fees Paid By: C�alifornia Bank Tru fiche e w
Bank Name/Recipient of Certificate
By Scott L. Bailey
Superintendent
Fee Collected/ Exempted by: Rodney Slagle
Check No.: 561061
Telephone: 760-200-0893
Funding: Residential
Certificate Fees Due: $2,008.70
Original Payment(s) Rec'd: $0.00
New Payment Rec'd: $2,008.70
Over/Under: $0.00
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
EsGi I
A SAFEbuilt Company
DATE: 07/31/2018 ❑ APPLICANT
❑ JURIS.
JURISDICTION: City of La Quinta
PLAN CHECK #.: BRES2018-0265 SET: I
PROJECT ADDRESS: 48775 Avenida El Nido
PROJECT NAME: Attached Casita (Structural Only)
❑ The plans transmitted herewith have been corrected where necessary and substantially comply
--with the jurisdiction's codes.
® The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building
department staff.
❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
❑ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
❑ The applicant's copy of the check list has been sent to:
® EsGil staff did not advise the applicant that the plan check has been completed.
❑ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: } Email:
Mail Telephone Fax In Person
® REMARKS: Please revise red -clouded plate washer size callouts on details 10/S-2.1 and 2/S-2
on any additional copies at the jurisdiction.
By: Ryan Murphy
EsGil
07/23/2018
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92I23 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Plan Submittal
Job Site
Building Permit Number:
Project Description: small casita addition
Exempt: ❑
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
9/6/2018
48775 Avenida El Nido
Owner's Namel
Radelle Deis & Lisa Rosenthal
Number, Street, or PO Boxi
48775 Avenida El Nido
City, State, Postal Code
La Quinta, CA. 92253
Owner's Phone Number
c/o 760-200-0893
Owner's E-Mail Address
Project Manager's Name I Ron Sawyer
Project Manager's Phone Number 760-200-0893 Cr�yy.
Project Managers E-mail Address ron.sa pp�� era maif.com f AEC r M EU
Builder / Contractor Ron Sawyer Const S E P 0 6 Z 0 1 8
Number, Street or PO Box 78525 Ave 41
City, State, Postal Code Bermuda Dunes, CA. 92203 `.CITY tjs'-''
V OIY11k�1li,l? f 'e rq T.:i: a;i t.r��!":�n.iY
Project Square Footage Approx. 530 sq ft
City Approval By Renado GDuldlock-f3EC/6urrtec Waste f
t 4,�
Date of City Approval
Materials To Be Discarded:
Product
Tons
Trash
2.25 Not recyclable
Product
Tons
Asphalt
Brick/Block
0.00 Recyclable
0.00 Recyclable
Masonry (broken)
0.00 Recyclable
Cardboard
0.00 Recyclable
Plaster
Scrap Metal
0.65 Recyclable
0.00 Recyclable
Commingled
Concrete
0.00 Recyclable
2.50 Recyclable
Tile (floor)
0.05 Recyclable
Drywall
0.25 Recyclable
Tile (roof)
Wood
0.07 Recyclable
0.75 Recyclable
Donated /Reuse*
0.00 Recyclable
Landscape Debris
0.00 Recyclable
*Describe Items
Totals: Rec cle Trash
4.3
L 2.3
Projected Diversion:
65.49%
I understand it Is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is
diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or
demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still
issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the
DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through
bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer
Owner! Developer —/ Project Manager / Superintendent
uate
BUILDING ENERGY ANALYSIS REPORT
Zo k &-,,- 0Z-Io5
PROJECT:
Rosenthal Res
48-775 Avenida El Ni
La Quinta, CA 9225
Project Designer:
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
o COMPLIANCE
UA �3 74 1 %Y
JMA Architecture and Engineering
73-995 El Paseo Suite 203
Palm Desert, CA 92260
(760) 346-6155
Report Prepared by:
Zack Sorensen
Scott Design and Title 24, Inc,
74818 Velie Way, Suite 8
Palm Desert, CA 92260
(760) 200-4780
RECEIVE
JUL 20 2018
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
Job Number:
Date:
7/11/2018
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
110
I TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF-1 R-PRF-01-E Certificate of Compliance
2
3
Form RMS-1 Residential MPaSi irP.q Si immary ill
CERTIr, TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 40D
Project Name: Rosenthal Res Addition CAculation Date/Time: 08:23, Wed, Jul 11, 2018
Calculation Description: Title 24 Analysis
Input File Name: tmpB854.tmp.xml
GENERAL
INFORMATION
01
Project Name
Rosenthal Res Addition
02
Calculation Description
Title 24 Analysis
03
Project Location
48-775 Avenida El Nido
04
City
La Quinta
06
Zip Code
92253
08
Climate Zone
CZ15
10
Building Type
Single Family
12
Project Scope
Addition and/or Alteration
14
Total Cond. Floor Area (ftZ)
3985
16
Slab Area (ftZ)
3985
18
Addition Cond. Floor Area (ftZ)
530
20
Addition Slab Area (ftZ)
530
CF 'RF-01
Page 1 of 10
05
Standards Version
Compliance 2017
07
Compliance Manager Version
BEMCmpMgr 2016.3.0 (1016 SP2)
09
Software Version
EnergyPro 7.2
11
Front Orientation (deg/Cardinal)
330
13
Number of Dwelling Units
1
15
Number of Zones
2
17
Number of Stories
1
19
Natural Gas Available
F22.
21
Glazing Percentage (%)%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
04
Energy Use (kTDV/ftZ-yr)
Space Heating
Space Cooling
IAQ Ventilation
Water Heating
Photovoltaic Offset
Compliance Energy Total
ENERGY USE SUMMARY
05 06
Standard Design ProTposed Design
5.46
157.78
0.00
5.16
168.40
4.93
155.73
0.00
4.90
0.00
165.56
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Insulation below roof deck
• Window overhangs and/or fins
07
Compliance Margin
0.53
2.05
0.00
0.26
0.00
2.84
08
Percent Improvement
9.7%
1.3%
0.0%
5.0%
1.7%
Registration Number: 218-Po10197619A-000-000-0000000-0000 Registration Date/Time:
2018-07-11 08:42:47 HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance CaICERTS inc.
Report Version - CF1 R-04302018-1016 SP2
Report Generated at: 2018-07-11 08:25:10
CERTIf TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE' -IOD CF j RF-01
Project Dame: Rosenthal Res Addition Calculation Date/Time: 08:23, Wed, Jul 11, 2018 Page 2 of 10
Calculation Description: Title 24 Analysis Input File Name: tmpB854.tmp.xml
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
Cooling System Verifications:
• Minimum Airflow
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
• -- None --
BUILDING - FEATURES INFORMATION
01 02 03
Number of Dwelling
Conditioned Floor Area (ftZ) Units
3985 1
Project Name
Rosenthal Res Addition
ZONE INFORMATION
01
Zone Name
Ex Residence
Bedroom Addition
02 1 03
04
05
Number of Bedrooms I Number of Zones
3 2
Zone Type HVAC System Name
Conditioned Existing HVAC1
Conditioned HVAC Casita2
04
05
Zone Floor Area
Avg. Ceiling
(ftZ)
Height
3455
9
530
9
06
Number of Ventilation
Cooling Systems
0
06
Water Heating System 1
DHW Sys 1
DHW Sys 3
07
Number of Water
Heating Systems
2
07
Water Heating System 2
n/a
n/a
Registration Number: 218-P010197619A-000-000-0000000-0000 Registration DateMme: 2018-07-11 08:42:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-07-11 08:25:10
CERTI( TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE40D
ProjectWame: Rosenthal Res Addition Calculation Date/Time: 08:23, Wed, Jul 11, 2018
Calculation Description: Title 24 Analysis
Input File Name: tmpB854.tmp.xml
CF 'RF-01
Page 3 of 10
OPAQUE SURFACES
01
02
03
04
06
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door
Area (ft2)
Tilt
(deg)
Status
Verified
Existing
Condition
60d Wall
Ex Residence
R-19 Wall (W.19.2x6.16)
60
Left
770
79.1 1
90
Existing
No
150d Wall
Ex Residence
R-19 Wall (W.19.2x6.16)
150
Back
940
174.4
90
Existing
No
240d Wall
Ex Residence
R-19 Wall (W.19.2x6.16)
240
Right
770
130.4
90
Existing
No
330d Wall
Ex Residence
R-19 Wall (W.19.2x6.16)
330
Front
940
346.2
90
Existing
No
Roof
Ex Residence
Default prior To 1978
3455
Existing
No
60d Wall 2
Bedroom Addition
R-21 Wall
60
Left
162
70.5
90
New
n/a
150d Wall 2
Bedroom Addition
R-21 Wall
150
Back
375
56.8
90
New
n/a
240d Wall 2
Bedroom Addition
R-21 Wall
240
Right
148
15.4
90
New
n/a
330d Wall 2
Bedroom Addition
R-21 Wall
330
Front
270
63.4
90
New
n/a
Interior Surface
Bedroom Addition»Ex
Residence
R-13 Wall
150
0
New
n/a
Roof 2
Bedroom Addition
R-38 Roof Attic R19
530
New
n/a
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool
Roof
Status
Verified Existing
Condition
Attic Ex Residence
Attic RoofEx Residence
Ventilated
0
0.1
0.85
No
No
Existing
No
Attic Bedroom Addition
Attic RoofBedroom Addition
Ventilated
3
0.1
10.85
1Yes
No
New
No
Registration Number: 218-P010197619A-000-000-0000000-0000 Registration Dateffime: 2018-07-11 08:42:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-07-11 08:25:10
CERTI( TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE ' iOD
Project Mime: Rosenthal Res Addition Calculation Date/Time: 08:23, Wed, Jul 11, 2018
Calculation Description: Title 24 Analysis
Input File Name: tmpB854.tmp.xml
CF JRF-01
Page 4 of 10
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multiplier
Area (ft)
U-factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
1.3 x 6.7
60d Wall (Left-60)
--
1
8.7
0.71
1 0.60
Insect Screen (default)
Existing
No
8 x 5.8
60d Wall (Left-60)
-
1
46.4
0.71
0.60
Insect Screen (default)
Existing
No
3 x 8
60d Wall (Left-60)
--
-
1
24.0
0.71
0.60
Insect Screen (default)
Existing
No
8 x 5.8 2
150d Wall (Back-150)
-
--
1
46.4
0.71
0.60
Insect Screen (default)
Existing
No
1 x 6
150d Wall (Back-150)
--
1
6.0
0.71
0.60
Insect Screen (default)
Existing
No
1 x 6 2
150d Wall (Back-150)
-
-
1
6.0
0.71
0.60
Insect Screen (default)
Existing
No
8 x 5.8 3
150d Wall (Back-150)
--
-
1
46.4
0.71
0.60
Insect Screen (default)
Existing
No
4.3 x 5.3
150d Wall (Back-150)
-
-
1
22.8
0.71
0.60
Insect Screen (default)
Existing
No
6 x 5
240d Wall (Right-240)
-----
1
30.0
0.71
0.60
Insect Screen (default)
Existing
No
2.8 x 3.3
240d Wall (Right-240)
-
-
1
9.2
0.71
0.60
Insect Screen (default)
Existing
No
2.8 x 8
240d Wall (Right-240)
-
----
1
22.4
0.71
0.60
Insect Screen (default)
Existing
No
2.8 x 8 2
240d Wall (Right-240)
-
1
22.4
0.71
0.60
Insect Screen (default)
Existing
No
5.8 x 8
240d Wall (Right-240)
--
--
1
46.4
0.71
0.60
Insect Screen (default)
Existing
No
3 x 3.4
330d Wall (Front-330)
----
1
10.2
0.71
0.60
Insect Screen (default)
Existing
No
12 x 8
330d Wall (Front-330)
-
--
1
96.0
0.71
0.60
Insect Screen (default)
Existing
No
2.8 x 8 3
330d Wall (Front-330)
1
22.4
0.71
0.60
Insect Screen (default)
Existing
No
7.8 x 8
330d Wall (Front-330)
-
-
1
62.4
0.71
0.60
Insect Screen (default)
Existing
No
5.8 x 8 2
330d Wall (Front-330)
-
1
46.4
0.71
0.60
Insect Screen (default)
Existing
No
7.8 x 8 2
330d Wall (Front-330)
--
-
1
62.4
0.71
0.60
Insect Screen (default)
Existing
No
2.8 x 8 4
330d Wall (Front-330)
-
---
1
22.4
0.71
0.60
Insect Screen (default)
Existing
No
4 x 6
330d Wall (Front-330)
----
1
24.0
0.71
0.60
Insect Screen (default)
Existing
No
3
60d Wall 2 (Left-60)
6.0
9.0
1
54.0 1
0.30
0.20
Insect Screen (default)
New
n/a
M
60d Wall 2 (Left-60)
1.0
6.0
1
6.0
0.30
0.20
Insect Screen (default)
New
n/a
I
60d Wall 2 (Left-60)
3.5
3.0
1
10.5
0.30
0.20
Insect Screen (default)
New
n/a
E
150d Wall 2 (Back-150)
----
1
15.8
0.30
0.20
Insect Screen (default)
New
n/a
F
150d Wall 2 (Back-150)
1
27.0
0.30
0.20
Insect Screen (default)
New
n/a
G
150d Wall 2 (Back-150)
- -
--
1
9.0 1
0.30
0.20
Insect Screen (default) I
New
n/a
H
150d Wall 2 (Back-150)
-
--
1
5.0 1
0.30 1
0.20
Insect Screen (default) I
New
n/a
Registration Number: 218-P010197619A-000-000-0000000-0000 Registration Date/Time: 2018-07-11 08:42:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-07-11 08:25:10
CERTI� TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project (Tame: Rosenthal Res Addition
Calculation Description: Title 24 Analysis
HOD
Calculation Date/Time: 08:23, Wed, Jul 11, 2018
Input File Name: tmpB854.tmp.xml
CF IRF-01
Page 5 of 10
B
240d Wall 2 (Right-240)
—
--
1
5.6
0.30
0.20
Insect Screen (default)
New
n/a
C
240d Wall 2 (Right-240)
—
1
5.6
0.30
0.20
Insect Screen (default)
New
n/a
D
240d Wall 2 (Right-240)
--
--
1
4.2
0.30
0.20
Insect Screen (default)
New
n/a
2
330d Wall 2 (Front-330)
--
--
1
20.0
0.30
0.20
Insect Screen (default)
New
n/a
L
330d Wall 2 (Front-330)
--•-
--
1
33.0
0.30
0.20
Insect Screen (default)
New
n/a
K
330d Wall 2 (Front-330)
—
1
6.8
0.30
0.20
Insect Screen (default)
New
n/a
J
330d Wall 2 (Front-330)
—
--
1
3.6
0.30
0.20
Insect Screen (default)
New
n/a
OPAQUE DOORS
01
02
03
04
05
06
Name
Side of Building
Area (ft)
U-factor
Status
Verified Existing Condition
6 x 7.8 Entry Door
150d Wall
46.8
0.50
Existing
No
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
1 14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
3
6
0.1
6
6
0
0
0
0
0
0
0
0
0
M
4
0.1
4
4
0
0
0
0
0
0
0
0
0
1
4
0.1
4
4
0
1 0
0
0
0
0
1 0
0
0
Registration Number: 218-P010197619A-000-000-0000000-0000 Registration Date/Time: 2018-07-11 08:42:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-07-11 08:25:10
CERTIr, TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE'
Project Name: Rosenthal Res Addition
HOD
CF
CTculation Date/Time: 08:23, Wed,
7RF-01
Jul 11, 2018
Calculation Description: Title 24 Analysis
Page 6 of 10
Input File Name: tmpB854.tmp.xml
OPAQUE SURFACE CONSTRUCTIONS
01 02
03 04 05
06
07
Construction Name Surface Type
Construction Type Framin Total Cavity Winter Design
9
R-value
U-factor Assembly Layers
Attic RoofEx Residence Attic Roofs
Wood Framed Ceiling 2x4 Top Chord Truss @ 24
• Cavity / Frame: no insul. / 2x4 Top Chrd
Roof Deck: Wood Sidinglsheathing/decking
'ofOCof
none
0.644 Rooting: Light Roof (Asphalt Shingle)
Ceilings (below
Inside Finish: Gypsum Board
Default prior To 1978 attic)
Wood Framed Ceilin 9 2x4 @ 16 in. O.C. R 11
Cavity/Frame: R-9.1 /2x4
0.083 Over Ceiling Joists: R-1.9 insul.
• Inside Finish: Gypsum Board
R-19 Wall (W. 1 9.2x6.16) Exterior Walls
Wood Framed Wall 2x6 16 in. O.C. R 19 in 5-1/2 in.
�o
CavitylFrame: R-19 in 5-1/2 in. (R-18) /2x6
cavity (R-18)
0.074 Exterior Finish: 3 Coat Stucco
• Around Roof Joists: R-6.0 insul.
Attic RoofBedroom Addition Attic Roofs
Wood Framed Ceiling 2x4 Top Chord Roof Truss @ 24
• Cavity/Frame: R-13.0/2x4 Top Chrd
Roof Deck: Wood Sidinglsheathing/decking
'off
R 19
0.059 Roofing: Light Roof (Asphalt Shingle)
Ceilings (below
Finish: Gypsum Board
R-38 Roof Attic R19 attic)
Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19
=Fltty/Frame: R-9.1 /2x4
Ceiling Joists: R-9.9 insul.
Finish: Gypsum Board
R-21 Wall Exterior Walls
Wood Framed Wall 2x6 @ 16 in. O.C. R 21
/Frame: R-21 /2x6
0.069 Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
R-13 Wall Interior Walls
Wood Framed Wall 2x4 16 in. O.C.
�° R 13
Cavity/Frame: R-13/2x4
0.092
Other Side Finish: Gypsum Board
SLAB FLOORS
01
02
03
04
05
06 07 08 09
Name
LEx
Zone
Area ftz
( )
Perimeter
(ft)
Carpeted
Verified
Existing
Slab -on -Grade
Residence
Edge Insul. R-value
Fraction
Heated
Status
Condition
Slab -on -Grade 2
Bedroom Addition
3455
530
0.1
132
None
0.8
No
Existing
No
None
0.8
No
New
No
BUILDING ENVELOPE - HERS VERIFICATION
01
Quality Insulation Installation (QII)
02 03 04
Quality Installation of Spray Foam Insulation Building Envelope Air Leakage
Required
Not Required Not Required
CFM50
n/a
Registration Number: 218-Po10197619A-000-000-0000000-0000 Registration Dateffime:
2018-07-11 08:42:47
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2
HERS Provider: CaICERTS inc.
Report Generated at: 2018-07-11 08:25:10
CERTIr TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE' !iOD
Project 17ame: Rosenthal Res Addition Calculation Date/Time: 08:23, Wed, Jul 11, 2018
Calculation Description: Title 24 Analysis Input File Name: tmpB854.tmp.xml
WATER HEATING SYSTEMS
01 02 03 04
Name System Type Distribution Type Water Heater
DHW Sys 1 DHW Standard DHW Heater 1
DHW Sys 3 DHW Standard DHW Heater 3
WATER HEATERS
01
02
03
04
06
06
07
08
Heater
Input Rating /
Tank
Tank
Uniform Energy
Pilot
Insulation
Element
Number
Volume
Factor / Energy
Thermal
R-value
Name
Type
Tank Type
of Units
(gal)
Factor I Efficiency
Efficiency
(Int/Ext)
DHW Heater 1
Gas
Small Storage
1
50
0.61 EF
40,000 Btu/hr
0
DHW Heater 3
Gas
Small
Instantaneous
1
0
0.99 EF
199,900 Btu/hr
0
SPACE CONDITIONING SYSTEMS
01 02
SC Sys Name System Type
Existing HVAC1 Other Heating and Cooling
System
HVAC Casita2 Other Heating and Cooling
System
HVAC - HEATING UNIT TYPES
01
Name
Heating Component 1
Heating Component 2
03 04
Heating Unit Name Cooling Unit Name
Heating Component 1 Cooling Component 1
Heating Component 2 Cooling Component 2
02
System Type
CntrlFurnace
CntrlFurnace
CF >RF-01
Page 7of10
05
Number of
Heaters
1
1
06
07
08
Solar
Fraction
N
Status
Verified Existing
Condition
0
Existing
No
0
New
No
09
Standby
Loss / Firs'
Recovery Ra
Eff i Flov
05
Fan Name
HVAC Fan 1
HVAC Fan 2
n/a I r
n/a I r
10
11
12
Hour
ing /
Rate
NEEA Heat Pump
Brand / Model
Tank Location
or Ambient
Condition
/a
n/a
n/a
/a
n/a
n/a
06
Distributic
Name
Air Distributi
System 1
Air Distributi
System 2
03
Number of Units
1
1
07
08
n
Status
Verified Existing
Condition
)n
Existing
No
)n
New
No
04
Efficiency
80 AFUE
80 AFUE
Registration Number: 218-Po10197619A-000-000-0000000-0000 Registration DateMme: 2018-07-11 08:42:47 HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-07-11 08:25:10
CERTI( TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE' 40D
Project Name: Rosenthal Res Addition Circulation Date/Time: 08:23, Wed, Jul 11, 2018
Calculation Description: Title 24 Analysis Input File Name: tmpB854.tmp.xml
CF )RF-01
Page 8 of 10
HVAC - COOLING UNIT TYPES
01
02
03 04 05 06
07
08
Efficiency
Name
System Type
Number of Units EER SEER Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
NoCooling
1
n/a
n/a
n/a
n/a
n/a
Cooling Component 2
SplitAirCond
1
11.7
13.1
Not Zonal
Single Speed
Cooling Component
2-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 2-hers-cool
Not Required
--..
Not Required
Not Required
Not Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R-value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Air Distribution
System 1
(Ventilated and
Sealed and tested
8.0
Attic
Attic
None I
New
No I
System
Unventilated)
1-hers-dist
Air Distribution
Ducts located in attic
Air Distribution
System 2
(Ventilated and
Sealed and tested
8.0
Attic
Attic
None
New
No
System
Unventilated)
2-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
Air Distribution System 2-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
HVAC - FAN SYSTEMS & HERS VERIFICATION
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
Required
Registration Number: 218-P010197619A-000-000-0000000-0000 Registration Date/Time: 2018-07-11 08:42:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-07-11 08:25:10
CERTI( TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE f 1013
Project Name: Rosenthal Res Addition Calculation Date/Time: 08:23, Wed, Jul 11, 2018
Calculation Description: Title 24 Analysis
Input File Name: tmpB854.tmp.xml
CF RF-01
Page 9 of 10
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
0
0.25
Default
0
Not Required
Registration Number: 218-P010197619A-000-000-0000000-0000 Registration DateMme: 2018-07-11 08:42:47 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-07-11 08:25:10
CERTIF TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 1 iOD
Project Name: Rosenthal Res Addition Calculation Date/Time: 08:23, Wed, Jul 11, 2018
Calculation Description: Title 24 Analysis Input File Name: tmpB854.tmp.xml
CF AF-01
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
7;r/-5'AZr
Company:
Signature Date:
Scott Design and Title 24, Inc.
2018-07-11 08:42:47
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
;z;el���
Tim Scott
Company:
Date Signed:
Scott Design and Title 24, Inc.
2018-07-11 08:42:47
Address:
License:
77085 Michigan Drive
N/A
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 218-P010197619A-000-000-0000000-0000 Registration Date/Time: 2018-07-11 08:42:47
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2
Q.,
Easy to Verify
at CaICERTS.com
HERS Provider: CaICERTS inc.
Report Generated at: 2018-07-11 08:25:10
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Res
' Building Type
10 Single Family ❑ Addition Alone
❑ Multi Family [0 Existing+ Addition/Alteration
112018
Project Address
48-775 Avenida El Nido La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,985
Addition
530
YDateRosenthal
of Units
1
INSULATION
Construction Type
Cavity
Area
ft Special Features Status
Roof Wood Framed Attic
R 11
3,455
Existing
Wall Wood Framed
R 19
2,690
Existing
Door Opaque Door
no insulation
47
Existing
Slab Unheated Slab -on -Grade
no insulation
3,455 Perim = 0'
Existing
Roof Wood Framed Attic
R 19
530 Add=R-19.0
New
Wall Wood Framed
R 21
749
New
Slab Unheated Slab -on -Grade
-
no insulation
530 Perim = 132'
New
Demising Wood Framed
R 13
150
Existing
FENESTRATION
Orientation Area ft2
Total Area: 889 Glazing Percentage: 22.3 %
U-Fac SHGC Overhang Sidefins
New/Altered Average U-Factor: 0.30
Exterior Shades Status
Left (NE) 79.1
0.710
0.60 none
none
Bug Screen Existing
Rear (SE) 127.6
0.710
0.60 none
none
Bug Screen Existing
Right (SW) 130.4
0.710
0.60 none
none
Bug Screen Existing
Front (NW) 346.2
0.710
0.60 none
none
Bug Screen Existing
Left (NE) 54.0
0.300
0.20 6.0
none
Bug Screen Existing
Left (NE) 16.5
0.300
0.20 4.0
none
Bug Screen New
Rear (SE) 56.8
0.300
0.20 none
none
Bug Screen New
Right (SW) 15.4
0.300
0.20 none
none
Bug Screen New
Front (NW) 63.4
0.300
0.20 none
none
Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
1 Central Furnace
80% AFUE
Split Air Conditioner 13.1 SEER
Setback
New
HVAC DISTRIBUTION
Location Heating
Coolinu
Duct Location
Duct
R-Value Status
HVAC Casila Ducted
Ducted
Attic
6.0
New
WATER HEATING
Qty. Type
Gallons
Min. Eff Distribution Status
1 Small Instantaneous Gas
0
0.99
Standard
New
Ener Pro 7.2 b v Ener Soft UserNumber.- 6712
ID:
Pa e 13 of 21
■ �} ,
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. *Exceptions may apply.
tOrialnal OW20161
Building Envelope Measures:
§ 110.6(a)l:
Air Leakage, Manufactured fenestration, exterior doors, and exterior pet doors mu
NFRC-400 orASTM E283orAAMA1WDMAICSA 1011I.S.2JA440-2011,'
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of §
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors ar
110,6-A and 110.6-B for com liance and must be caulked andfor weatherstri -d.
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope t
asketed, or weather stripp ed.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must r
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be ins
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emltt
material must meet the re uiremen!s of 110.8 i when the instaliatlon of a cool ro[
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be cf
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceilin
§ 150.0(a):
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteratic
insulation
using adhesive or mechanical fasteners. The attic access must be gasket
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and
to placing insulation either above or below the roof deck or on to of a d all ceilPni
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required di
§ 150.0(c):
st limit air leakage to 0.3 cfm/ft2 or less when tested per
10-111(a).
d solar heat gain coefficient (SHGC) values from TABLES
iat are potential sources of air leakage must be caulked,
neet Standards for Insulating Material.
ulated per the requirements of § 110.8(g).
once and aged solar reflectance 'values the roofing
d is s ecified on the CF1 R.
;rtified to the Department of Consumer Affairs.
g; or the weighted average U-factor must not exceed 0.043.
m. Attic access doors must have permanently attached
ed to prevent air leakage. Insulation must be installed in
exfiltration as specified in § 110.7, including but not limited
�nsity for the labeled R-value.
Yvan msuiation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or
wood framed assemhiv'
less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a
§ 150.0(d): Raised -floor Insulation. Minimum R-19 insulation In raised wood framed floor or 0.037 maximum U-factor.'
§ 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration; and, when installed as part of a healed slab floor, meet the re uirements of § 110.8 .
§ 150.0(g)l: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
re uirement also a P PIies to controlled ventilation crawls ace for buildings complyin2 with the exception to J 150.Q d V§ 150.0(g)2: apor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
sulation in all exterior walls, vented attics, and unvented attics with airmpermeable Insulation.
§ 150.0(q): Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58; or the weighted averse Ll-factor of all fenestration must not exceed 0,58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1 B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches In area
and is eguipped with a readily accessible o erable, and fight-fiffingi damper or combuslion-air control device.'
§ 150.0(e)l C: Flue Damper, Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the buildin , are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
a liances must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
cam ression heating is higher than the cut-off temperature for supplementary heating.'
§ 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3 c 5.
§ 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittin s on both cold water and hot water lines of water heating systems to allow for water tank flushf i when the valves are closed.
§ 110.5: Pilot Lights, Continuously burning pilot lights are prohibited for natural gas: fan -type central fumaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt and pool and spa heaters.
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)1: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditlons specified in 6 150.0ih17
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
dryer vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.'
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve.'
§ 150 00)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
piping for steam and h dronle heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.'
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.00)36�
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)1;
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 156.6(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Cor oratlon SRCC. or by a listing age n cthat is a pproved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the cuslomer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1.
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such toe Is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all o enin s to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0(m)11 and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of § 150.0(m)12.
OM 2016 Low -Rise Residential Mandatory Measures Summary
I
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy15 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced airs stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole- uilding ventilation.
§ 150.0(o)1A:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.*
§ 110.4(b)1:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar hearing.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pum s to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
§ 150,0(p):
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, piping, filters, and valves.'
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of 110.9.'
§ 110.9(e):
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fanspeed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1 C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)1 D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors.
§ 150.0(k)1 F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of§ 150.0(I�).'
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1 G:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8.'
§ 150.0(k)1 H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JAB compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5(f); and meets all other requirements in § 150.0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5 ; and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to § 110.9, and complies with all other a ![cable requirements in § 150.0(k)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.'
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS).
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either § 150.0 k 3A or with the applicable requirements in &§ 110.9, 130.0,130.2, 130.4,140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0 k 3B'or § 150A k 3D must comply with the applicable re uirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting, Outdoor Iighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must cam 1 with the applicable requirements in §§ 110.9 130.0, 130.2,130.4, 140.7 and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4. 14.0.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1�
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.10(b) through § 110.10(e).
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d)
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.*
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical plane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system.
§ 110.10(d).
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.10 c must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel, The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanentIX marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Rosenthal Res
Date
7/11/2018
System Name
Existing HVAC
Floor Area
3,455
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
COIL
CFM
Total Room Loads 3,766
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation o
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
72,150
3,890
1,087
47,139
Total Output (Btuh)
0
Output Btuh/s ft
4,165
2,317
Cooling System
0
0
Output per System
0
0
0
0
Total Output Btuh
0
4,165
80,480 3,890
0
Total Output Tons
2,317
Total Output Btuh/s ft)
Total Output s ft/Ton
51,773
Air System
CFM per System
HVAC EQUIPMENT SELECTION
Airflow cfm
Airflow cfm/s ft)
Airflow cfm/Ton)
Outside Air %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
Outside Air cfm/s ft
1 Note: values above given at ARI conditions
Aug 3 PM
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak)
26 OF
Outside Air
0 cfm
67 OF
67 OF 110 OF
Heating Coil
i
UTI
109 OF
ROOM
68 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112/78OF
Air-4r
0 cfm
77/63OF
77/63OF 55/54OF
HJOutside
J
Cooling Coil
T-1 4
I . L
57 155 OF
48.5 % ROOM
75/62OF
EnergyPro 7.2 by EnergySoft
User Number: 6712
ID: +' .; 18 of 21
HV��.SYSTEM HE
AND COOLING LOADS SUMMARY
Proje
Rosenthal Res Date
system Name 7/11/2018
HVAC Casita Floor Area
ENGINEERING CHECKS 530
SYSTEM LOAD
Number of Systems 1
COIL COOLING PEAK COIL HTG. PEAK
Heating System
CFM Sensible Latent CFM Sensible
Out ut per 5 stem 66,000 Total Room Loads 399 8,258 597 296
10,831
Total Ou ut Btuh 66,000 Return Vented Lighting 0
Output Btuhls ft 124.5 Return Air Ducts 477
532
CoolingSystem Return Fan 0
0
Out ut per System 24,800 Ventilation 0 0
� o 0
Total Output Btuh 24,800 Supply Fan 0
0
Total Out ut Tons 2.1 Supply Air Ducts 477
532
Total Out ut 8tuhls ft 46.8
Total Out ut s ftlTon 256.5 TOTAL SYSTEM LOAD 9,211 597
Air S stem 11,895
CFM per System 800 HVAC E[UIPMENT SELECTION
Airflow (cfml 800 Carrier24ANB724 18,833 2,116
66,000
Airflow cfrnlsgft 1.51
AfrflOw cfm/Ton 387.1
Outside Air °I° 0.0 °I° Total Adjusted System Output 18,833 2,116
9 66,000
Outside Air cfmis ft 0.00 (Adjusted For Peak Design canditfons)
Note: values above given at ARI conditions I TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS Airstream Tern Deratures at Time of Heatin Peak
26 IF 69 OF 105 OF
105 OF
OutsideAir �I I................................... ............................. . . .
0 cfm Heating Coil Supply Fan
800 cfm 104 IF
69 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of C,
112/78IF 76/62°F 55/54°F
55/54 OF
Outside Air Q
0 cfm Cooling Coil Supply Fan
800 cfm
76 / 62 IF
EnargyPro 7.2 by EnergySoR User Number. 6712
Pea
ROOM
70 OF
56/54°F
46.9 % ROOM
75/62°F
ID. Page 19 of 21
ZONE LOAD SUMMARY
Project Name
Rosenthal Res
Date
711112018
System Name
Existing HVAC
Floor Area
3,455
ZONE LOAD SUMMARY
ZONAL SYSTEM
—CFM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
Sensible
Ex Residence
1.0
0
Aug 3 PM
3,766
72,150
3,890
1,087
47,139
TOTALS
0
0
01
01
Aug 3 PM
72,150 f
3,890
47,139
(BLOCK LOAD)
EnergyPro 7.2 by EnergySoft User Number- 6712 ID Page 20 of 21
ZONE LOAD SUMMARY
Project Name
Rosenthal Res
Date
711112018
System Name
HVAC Casita
Floor Area
530
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heatina
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
Sensible
Bedroom Addition
1.0
0
Aug 3 PM
1 399
8,258
597
296
10,831
TOTALS
0
0
0
0
Aug 3 PM
8,258
597
10,831
(BLOCK LOAD)
EnergyPro 7.2 by LnergySaft User Number: 6712 ID: Page 21 of 21