BRES2018-028778-495 (:ALLE 7AMPICO C&t!t D 4a" VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 9/14/2018
Permit Type/Subtype: BUILDING RESIDENTIAL/ADDITION Owner:
Application Number: BRES2018-0287 NICOLA AND WALLACE OPDYCKE
Property Address: 80835 VIA PORTOFINO 80835 VIA PORTOFINO
APN: 777150023 LA QUINTA, CA 92253
Application Description OPDYCKE / 170 SF ADDITION
Property Zoning:
Application Valuation: $46,000.00
2" 0
Applicant: Ij p Contractor:
MICHAEL JEHA CONSTRUCTION D1�.1�� ttl MICHAEL JEHA CONSTRUCTION
53408 VIA PISA 53408 VIA PISA
LA QUINTA, CA 92253 SEp 14 2018 LA QUINTA, CA 92253
(925)250-4038
[ Ct I Y OF LA I_ ; fA Llc. No.: 410408
,J11�('`�:� 117F�1+�`!
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 70001 of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B License No.: 4 08
Date: r Contractor:
OWNER -BUILDER DEC RATION
I hereby affirm under penalty of perjury that I am xempt fr the Contractor's State
License Law for the following reason (Sec. 7031.5, B s and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) 1, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
() I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
oft Vw for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
inf the Labor Code, for the performance of the work for which this permit
workers' compensation insurance carrier and policy number are:
PT Policy Number:
rtify that in the performance of the work for which this permit is issued, I
oy any person in any manner so as to become subject to the workers'
laws of California, and agree that, if I should become subject to the
ensation provisions of Section 3700 ofthe r Code, I sh erNt
comply with those provisions.
Date: I Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION VERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state la relating to building
construction, and hereby authorize represents o is 'ty ent pon the
above -mentioned property for in ection p ases.
Date: Ignature (Applicant or Agent
Lender's Address
Date: 9/�4/2018
Application Number:
BRES2018-0287
Property Address:
80835 VIA PORTOFINO
APN:
777150023
Application Description:
OPDYCKE / 170 SF ADDITION
Property Zoning:
Application Valuation:
$46,000.00
Applicant:
MICHAEL JEHA CONSTRUCTION
53408 VIA PISA
LA QUINTA, CA 92253
Owner:
NICOLA AND WALLACE OPDYCKE
80835 VIA PORTOFINO
LA QUINTA, CA 92253
Contractor:
MICHAEL 1EHA CONSTRUCTION
53408 VIA PISA
LA QUINTA, CA 92253
(925)250-4038
Llc. No.: 410408
Detail: 170 SF OFFICE ADDITION [RA ENGINEERING]. THIS PERMIT DOES NOT INCLUDE ALTERATIONS TO OTHER AREAS OF DWELLING. 2016 CALIFORNIA
BUILDING CODES.
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT
CITY
AMOUNT
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400
0
$67.10
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$18.72
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ADDITION, FIRST 100 SF
101-0000-42400
0
$131.07
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$184.13
Total Paid for ADDITION: $401.02
DESCRIPTION ACCOUNT CITY AMOUNT
HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 0.5 $78.00
DESCRIPTION ACCOUNT CITY AMOUNT
HOURLY CHARGE - ESGIL PLANS EXAMINER 101-0000-42600 1.5 $135.00
Total Paid for BLDG CITY STAFF - PER HOUR: $213.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$2.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20
101-0000-42403
0
$26.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20 PC
101-0000-42600
0
$26.01
Total Paid for ELECTRICAL: $52.02
DESCRIPTION
ACCOUNT
CITY
AMOUNT
APPLIANCE REPAIR/ALTERATION
101-0000-42402
0
$13.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
APPLIANCE REPAIR/ALTERATION PC
101-0000-42600
0
$5.20
Total Paid for MECHANICAL: $18.20
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PLAN CHECK DEPOSIT - ADDITION/REMODEL
101-0000-42600
1
$125.00
Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RECORDS MANAGEMENT FEE - MAJOR
101-0000-42416
0
$20.00
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $20.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$5.98
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $5.98
DESCRIPTION ACCOUNT QTY AMOUNT
TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
PERMIT #
PLAN LOCATION:
Project Address: �A r
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN
OJ
Applicant Name:
OLA
L�
Address:
b�
City, ST, Zip:
Telephone:
Email:
Valuation of Project $j
Contractor Name: (
I
New SFD Construction:
� / �
5-3qal�
�6
Conditioned Space SF
City, St, Zip
Z
Garage SF
Telephone: 9ZS —2O
Patio/Porch SF
Email:
'v L
i e Sprinklers SF
State Lic: City Bus Lic:
Arch/Eng Name:
Construction Type: Occupancy:
Address:
Grading:
City, St, Zip
Telephone:
Bedrooms: Stories: # Units:
Email:
State Lic: City Bus Lic:
Property Owner's Name:
New Commercial / Tenant Improvements:
Address: `
Total Building SF
City, ST, Zip
Construction Type: Occupancy:
Telephone:
Email:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
OFFICE USE ONLY
#
Submittal.
Req'd
•Rec'd
Plan Sets
Structural Calcs
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Bun-tec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
CITY OF LA QUINTA SUB —CONTRACTOR. LIST
�D—
r�
T r t/G14 U�
PERMIT NUMBEI"��'��OWNER `� w BUILDER
JOB ADDRESS —
�pes:�
This form shall be posted an the 'ab with the BuildingIns peption Card at all times in a cans icuous lace. O appearing on this list or their employees are authorized to work
in a stoppage of work and/or the voidance
on this job. Any changes to this list must be approved by
the Building Division prior to commencement of work. Failure to comply will result
of building, ;:permit. For
each applicable trade, all information
requested below must be competed by applicant. "On File" is not an acceptable response.
-.
..
:Trade:a:.Classifticatir�r�
........ .:;:;. ' : L'.a.rrtraetar:. .v..
.::::--.,
Cit 13. siriess Lireri.s.e ••
tci's License - :;. v ..ers;:Ccmpen..a.tro.ii Irs-ranee :..::> : - ::: J.:: �.Y �?
ntrac ' ::::: .. � ^..:
State. Ca -
.-.-
Company Name
Classification License Number Exp. Date Carrier Name Policy Number Exp. Date License Number Exp. Date
(e.g. A, B, C 8) (xxxxxx) ixxl�,xlxT1(Ceg,:e . Fund, CalComp) (Format Varies) (xx/xx/x ! (xxxx) (xx/xx/xx)
r
�f3�il $ 3a veNr�ao,>pr� l�s, —I �0000 3100 !0 2< <o a I o Z3c� cP
EARTHWORK {c=i.
CONCrE•rl= (C-s)
t
- W ----------
r
L — `
FRAhIlN13-
S:Tkuur: STEEL (C-51)..
MASONRY (C-29):....
`
F':LUMI3ING (C 36)
r T
LATH,. PLASTLR.(C-?5)
(C-a)
=k�tk-
9c)❑RvwAiL
(C-1C)
I � �I� — CO ` GS-� ���6 23 / i �/�, �9
ELECTRICAL ::
, �
l7
�toa irvG'ic psi:-...
SHEET METAL iC-4:3) :
FLOORING (G: 15)
GLAZING (C-17:):::.;
INSULATION (C-2) ..
SEWAGE DISP. (C-42) ..
.PAINTING (C 33)
C.ERAMI.0 1ILE:.:(C-54) :....
CABINETS (G-6.) .
FENCG (C-13)
LANDSCAPING=(G.-2..7)
POOL (C-53)
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
RECEIVED
AUG 12 2018
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMM/MD. AMOUNT:
DATE:
RECEIPT:
CHECK#:
INITIALS
('Tl` QF U, QUINTA CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
proye'PP �� NELu 'Ma4PARTMENT Date: September 7, 2018
Owner's Name: Nicola Opdycke Phone No. 925-250-4038
Project Address: 80-835 Via Portofino, LaQuinta
Project Description: Addition
APN: 777-150-023
Tract #:
Type of Development: Residential XX
Commercial
Total Square Feet of Building Area: 170 sq. ft.
Lot #'s:
Industrial
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to 'R on behalf of the owner/developer.
Dated: September 7, 2018 Signature:
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE
PRO.IE T HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: lC FRCLE ON
Education Code Gov. Code Project Agreement Existing Not Subject to Fee
17620 65995 Approval Prior to 1/l/87 Requirement
Note:
Number of Sq.Ft. 170 Pursuant to AB 181 any room additions or enclosures of 500
Amount per Sq.Ft. $0.00 sq. ft. or less are exempt from developer fees. Any mobile
homes being relocated within the same school district's
Amount Collected $0.00 jurisdiction are exempt from developer fees.
Building Permit Application Completed: Yes/No
By: Andy Jenkins, Interim Dir. Facilities Dev. & Planning
Certificate issued by: Laurie Howard Secretary Signature: r ,��B1JL
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90-day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90-day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance
is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3)
such extensions may be granted.
�1\:� ;in.,l�•� n �h� i�.'; rir�li; all ofc�sn,�,ILIm._r Ihrnn upd.uhtl-r't}(1- 11/2010
From: Brook Marshall drefacilitator@gmail.com
Subject: RE: Approval letter
Date: September 11, 2018 at 10:49 AM
To: Mike Jeha jehaconstruction@aol com, smillan@drminternet.com
Mike:
A revised set of working drawings was required for final approval, per the letter copied below (from July):
July 9, 2018
Mr. and Mrs. Wallace and Nicola Opdycke
27 East Bay Boulevard
Spring, TX 77380
RE: Lot 150 at 80835 Via Portofino
Office Addition
Dear Mr. and Mrs. Opdycke,
Ca.
This correspondence shall serve as notification that The Hideaway Design Review Committee (DRC) reviewed your architectural
modification proposal at the July 3, 2018 meeting. The request to add a (266 sf) office was conceptually approved based on the
previous owner's preliminary plans. A revised set of working drawings, for this addition only, will be required for final approval
prior to starting construction. In addition, the following comments will need to be addressed with your next submittal.
1. The lot was increased in size therefore typically the side yard setbacks should be increased. As only a small portion of land
was added you are only required to increase the side yard setback by one -foot making it an 11' side yard setback on one side.
2. There is a viewing pad proposed in the active use area which is not allowed per the guidelines.
3. Revised planting and hardscape plans are required for final approval and should include the proposed development of the
additional piece of property that abuts Lot 151.
4. If additional architectural modifications are being pursued please resubmit as the committee was directed to only review the
Office addition.
We look forward to receiving your revised submittal that relates to this specific request. Please contact Brook Marshall at (760)
219-8057 or by email at DRCFacilitator@gmail.com with any questions regarding this matter.
THE
J �1
From: Mike Jeha[mailto:jehaconstructtongaol.coml
Sent: Tuesday, September 11, 2018 9:59 AM
To: Brook Marshall; brook@dc.rr.com; smillan0drminternet.com
Subject: Approval letter
Girls do u have or can u get me approval letter for old Goldstein house where we're adding 170 sq ft to right side yard city asking
for it I know was approved
Thks
Sent from my iPhone
R E V E D
AUG 12 2018
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
Building Permit Number: Ismail
Project Description: room addition
Exempt: 3
(Materials may contain hazardous wastes and
are not subject tc recycling provisions)
Construction Debris Management Plan
Plan Submittal Date] 9/7/2018
Job Site
Owner's Name
Number, Street, or PO Box
City, State, Postal Code
Owner's Phone Number
Owner's E-Mail Address
Project Manager's Name
Project Manager's Phone Number
Project Manager's E-mail Address
80835 Via Portofino
Nicola Opdycke
80835 Via Portofino
La Quinta, CA. 92253
808-785-6547
Michael Jeha
925-250-4038
Lhacnnorvction paol.cam
RECEIVED
AUG 12 2018
Builder/Contractor
Jeha Construction
Number, Street or PO Box
53408 Via Pisa CM OF IA QUINTA
City, State, Postal Code
La Quinta, CA. 92253 DESIGN AND DEVELOPMENT DEPARTMENT
Project Square Footage
Approx. 170 sq ft
City Approval By
Renado G❑uldlock-DEC/Burrtec Waste ` i-
Date of City Approval
0)1)
Materials To Be Discarded:
Product
Trash
Asphalt
Brick/Block
Cardboard
Commingled
Concrete
Drywall
Donated / Reuse*
*Describe Items
Tons
0,70 Not recyclable
0.00 Recyclable
0.00 Recyclable
0.00 Recyclable
0.00 Recyclable
0.75 Recyclable
0.08 Recyclable
0.00 Recyclable
Totals: Recycle Trash
1.3 L_ 0.71
Product
Masonry (broken)
Plaster
Scrap Metal
Tile (floor)
Tile (roof)
Wood
Landscape Debris
Tons
0.00 Recyclable
0.20 Recyclable
0.00 Recyclable
0.02 Recyclable
0.25 Recyclable
0.00 Recyclable
Projected Diversion:
B5.86°k
I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is
diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or
demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still
issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the
DMP are adhered to. The property owner(s) and general contractor shall be kept Informed of the diversion progress through
bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recyceer or transfer
Owner / Developer / Project Manager / Supa6ntendant Date
vuEsGil
DATE: 8/48/2018
1
JURISDICTION: City of La Quinta
PLAN CHECK #.: BRES2018-0287.STRUCTURAL
PROJECT ADDRESS: 80835 Via Portfolio
PROJECT NAME: Office Addition for Opdycke Residence
❑ APPLICANT
JURIS.
SET: I
® The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
❑ The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
[} The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
❑ The applicant's copy of the check list has been sent to:
® EsGil staff did not advise the applicant that the plan check has been completed,
❑ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted:— Telephone #:
Date contacted: ) Email:
Mail Telephone Fax gin er5on
REMARKS:
By: Rich Moreno Enclosures:
EsGil
8/17/2018
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
I BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Portofino Res Addition
80-835 Via Portofino
La Quinta, CA 92253
Project Designer:
brock j. payton, inc
8391 Beverly Blvd., Suite 482
Los Angeles, CA 90048
(310) 720-6589
Report Prepared by:
Jon d. Scott
Scott Design and Title 24, Inc,
74818 Velie Way Suite 8
Palm Desert, CA 92260
(760) 200-4780
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
O PLIANCE
ob Number:
Date:
8/16/2018
RECEIVED
AUG 16 2018
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF-1 R-PRF-01-E Certificate of Compliance 3
Form RMS-1 Residential Measures Summary 12
Form MF-1 R Mandatory Measures Summary 14
HVAC System Heating and Cooling Loads Summary 18
Room Load Summary 19
CER :ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANC
Project Name: Portofino Res
Calculation Description: Title 24 Analysis
.THOD
Calculation Date/Time: 14:52, Thu, Aug 16, 2018
Input File Name: Portofino Remodel -Brock Payton-18.ribd16x
-PRF-01
Page 1 of 9
GENERAL INFORMATION
01
Project Name
Portofino Res
02
Calculation Description
Title 24 Analysis
03
Project Location
80-835 Via Portofino
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.2
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
270
12
Project Scope
Addition and/or Alteration
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft)
5433
15
Number of Zones
2
16
Slab Area (ftZ)
5433
17
Number of Stories
1
18
Addition Cond. Floor Area (ft)
170
19
Natural Gas Available
Yes
20
Addition Slab Area (ft)
170
21
Glazing Percentage (%)
19.9%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ftZ-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
2.79
1.98
0.81
29.0%
Space Cooling
144.96
137.86
7.10
4.9%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
5.45
5.45
0.00
0.0%
Photovoltaic Offset
--
0.00
0.00
----
Compliance Energy Total
153.20
145.29
7.91
5.2%
Registration Number: 218-P010233762A-000-000-0000000-0000 Registration Date[Time: 2018-08-16 15:03:14 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-08-16 14:53:18
CER' :ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANC' :THOD-PRF-01
Project Name: Portofino Res Calculation Daterrime: 14:52, Thu, Aug 16, 2018 Page 2 of 9
Calculation Description: Title 24 Analysis Input File Name: Portofino Remodel -Brock Payton-18.ribdl6x
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cool roof
• Insulation below roof deck
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
Cooling System Verifications:
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
-- None --
BUILDING - FEATURES INFORMATION
01
02
03
04
fly
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Portofino Res
5433
1
3
2
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Existing
Conditioned
HVAC 11
5263
10
DHW Sys 1
n/a
Addition
Conditioned
HVAC 11
170
10
DHW Sys 1
n/a
Registration Number: 218-P010233762A-000-000-0000000-0000 Registration DateMme: 2018-08-16 15:03:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-08-16 14:53:18
CER" 'ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCI ;THOD
Project Name: Portofino Res Calculation Date/Time: 14:52, Thu, Aug 16, 2018
Calculation Description: Title 24 Analysis
Input File Name: Portofino Remodel -Brock Payton-1 8.ribdl 6x
-PRF-01
Page 3 of 9
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
11
Name
Zone
Construction
Azimuth
Orientation
Gross Area
(ft)
Window & Door
Area (ft)
Tilt
(deg)
Wall
Exception
Status
Verified
Existing
Condition
N wall
Existing
R-19 Wall
0
Left
862
129
90
n/a
Existing
No
E wall
Existing
R-19 Wall
90
Back
862
213
90
n/a
Existing
No
S wall
Existing
R-19 Wall
180
Right
862
234
90
n/a
Existing
No
W wall
Existing
R-19 Wall
270
Front
862
448
90
n/a
Existing
No
Roof
Existing
R-30 Roof
5263
n/a
New
n/a
N Wall 2
Addition
R-21 Wall
0
Left
120
57
90
none
New
n/a
Interior Surface
Addition>>Existing
R-0 Interior Wall
170
0
n/a
New
n/a
Interior Surface 2
Addition»Existing
R-0 Interior Wall
170
0
n/a
New
n/a
Interior Surface 3
Addition>>Existing
R-0 Interior Wall
170
0
n/a
New
n/a
Interior Surface 4 1
Addition»Existing
R-0 Interior Wall
170
0
n/a
New
n/a
Interior Surface 5
Addition»Existing
R-0 Interior Wall
170
0
n/a
New
n/a
Interior Surface 6
Addition>>Existing
R-0 Interior Wall
170
0
n/a
New
n/a
Roof 2
Addition
R-38 Roof wl R19
170
n/a
New
n/a
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool
Roof
Status
Verified Existing
Condition
Attic Existing
Attic RoofExisting
Ventilated
0
0.1
0.85
No
No
New
No
Attic Addition
Attic RoofAddition
Ventilated
13
10.6
10.8
1 Yes
Yes
New
No
Registration Number: 218-P010233762A-000-000-0000000-0000 Registration DateMme: 2018-08-16 15:03:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-08-16 14:53:18
CER' :ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANC' :THOD
Project Name: Portofino Res Calculation Date/Time: 14:52, Thu, Aug 16, 2018
Calculation Description: Title 24 Analysis
Input File Name: Portofino Remodel -Brock Payton-1 8.hbdl 6x
'.-PRF-01
Page 4 of 9
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multiplier
Area (ft)
U-factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
Ex Window
N wall (Left-0)
-
-
1
48.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 2
N wall (Left-0)
-
1
48.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 3
N wall (Left-0)
-
1
16.5
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window-
N wall (Left-0)
-
-
1
16.5
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 4
E wall (Back-90)
-
-
1
1.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 5
E wall (Back-90)
-
1
1.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 6
E wall (Back-90)
-
-
1
1.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 7
E wall (Back-90)
-
-
1
48.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 8
E wall (Back-90)
-
1
48.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 9
E wall (Back-90)
-
-
1
48.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 10
E wall (Back-90)
-
1
15.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 11
E wall (Back-90)
-
-
1
15.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 12
E wall (Back-90)
-
-
1
36.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 13
S wall (Right-180)
-
-
1
6.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 14
S wall (Right-180)
-
-
1
6.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 15
S wall (Right-180)
-
-
1
1.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 16
S wall (Right-180)
-
----
1
1.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 17
S wall (Right-180)
- -
-
1
36.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 18
S wall (Right-180)
-
-
1
1.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 19
S wall (Right-180)
-
---
1
6.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 20
S wall (Right-180)
----
-
1
48.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 21
S wall (Right-180)
-
--
1
96.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 22
S wall (Right-180)
-----
1
16.5
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 23
S wall (Right-180)
-
-
1
16.5
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 24
W wall (Front-270)
-
1
96.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 25
W wall (Front-270)
-
-
1
160.0
0.71
0.60
Insect Screen (default)
Existing
No
Ex Window 26
W wall (Front-270)
-
-
1
96.0
0.71
0.60
Insect Screen (default)
Existing
I No
Ex Window 27
W wall (Front-270)
-
1
48.0
0.71
0.60
Insect Screen (default)
Existing
No
Registration Number: 218-P0102337624-000-000-0000000-0000 Registration Dateffime: 2018-08-16 15:03:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-08-16 14:53:18
CER' :ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANC .THOD
-PRF-01
Project Name: Portofino Res
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:52, Thu, Aug 16, 2018
Input File Name: Portofino Remodel -Brock Payton-18.dbd16x
Page 5 of 9
Ex Window 28
W wall (Front-270)
--
—
1
48.0
0.71
0.60
Insect Screen (default)
Existing
No
New Window
N Wall 2 (Left-0)
3.0
5.5
1
16.5
0.30
0.20
Insect Screen (default)
New
n/a
New Window 2
N Wall 2 (Left-0)
3.0
8.0
1
24.0
0.30
0.20
Insect Screen (default)
New
n/a
New Window 3
N Wall 2 (Left-0)
3.0
5.5
1
16.5
0.30
0.20
Insect Screen (default)
New
n/a
OVERHANGS AND FINS
01
02
1 03
04
05
06
07
08
09
10
11
12
13 1 14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
New Window
2
0.1
2
2
0
0
0
0
0
0
0
0
0
New Window 2
2
0.1
2
2
0
0
0
0
0
0
0
0
0
New Window 3
2
0.1
2
2
0
0
0
0
0
0
0
1 0
1 0
� CaICERTS, Inc,
Registration Number: 218-Po10233762A-000-000-0000000-0000 Registration Date/Time: 2018-08-16 15:03:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-08-16 14:53:18
CER' :ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANC' ITHOD
-PRF-01
Project Name: Portofino Res
Calculation Description: Title 24 Analysis
Calculation Daterrime: 14:52, Thu, Aug 16, 2018
Input File Name: Portofino Remodel -Brock Payton-18.ribd16x
Page 6 of 9
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofExisting
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Rooting: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-30 Roof
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 30
0.032
Over Ceiling Joists: R-20.9 insul.
Inside Finish: Gypsum Board
• Cavity/Frame: R-23/2x6
R-19 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C-
R 23
0.066
Exterior Finish: 3 Coat Stucco
• Around Roof Joists: R-6.0 insul.
• Cavity/Frame: R-13.0 /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofAddition
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 19
0.059
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof w/ R19
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
Inside Finish: Gypsum Board
Cavity/Frame: R-21 /2x6
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O_C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
Inside Finish: Gypsum Board
Cavity/Frame: no insul. /2x4
R-0 Interior Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.277
Other Side Finish: Gypsum Board
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft)
Perimeter
(ft)
Edge Insul. R-value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Slab -on -Grade
Existing
5263
261
None
0.8
No
New
No
Slab -on -Grade 2
Addition
170
12
None
0.8
No
New
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
n/a
Registration Number: 218-Po10233762A-000-000-0000000-0000 Registration Date/Time: 2018-08-16 15:03:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-08-16 14:53:18
CER' ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANC' 'THOD
Project Name: Portofino Res Calculation Date/Time: 14:52, Thu, Aug 16, 2018
Calculation Description: Title 24 Analysis
Input File Name: Portofino Remodel -Brock Payton-18.ribdl6x
-PRF-01
Page 7 of 9
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
2
0
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Input Rating /
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
NEEA Heat Pump
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Brand / Model
Condition
DHW Heater 1
Gas
Small Storage
2
1 50
1 0.61 EF
<= 75 kBtu/hr
0
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
Distribution
Verified Existing
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Name
Status
Condition
HVAC 11
Other Heating and Cooling
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution
Altered
No
System
System 1
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFurnace
3
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Efficiency
Name
System Type
Number of Units
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
3
12.7
16
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Registration Number: 218-P010233762A-000-000-0000000-0000 Registration DateMme: 2018-08-16 15:03:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-08-16 14:53:18
CER' :ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANC' THOD
Project Name: Portofino Res Calculation Date/Time: 14:52, Thu, Aug 16, 2018
Calculation Description: Title 24 Analysis
Input File Name: Portofino Remodel -Brock Payton-18.ribd16x
-PRF-01
Page 8 of 9
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Not Required
n/a
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R-value
Location
Location
Bypass Duct
Status
Condition
Verification
Ducts located in attic
Air Distribution
Air Distribution
(Ventilated and
Sealed and tested
8.0
Attic
Attic
None
Existing + New
No
System
System 1
Unventilated)
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
, 15.0
Not Required
Not Required
Not Required
Not Required
n/a
HVAC - FAN SYSTEMS & HERS VERIFICATION
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.54
Required
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
0
0.25
Default
0
Not Required
Registration Number: 218-P010233762A-000-000-0000000-0000 Registration Date/Time: 2018-08-16 15:03:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-08-16 14:53:18
CER" 'ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 'THOD
Project Name: Portofino Res Calculation Daterrime: 14:52, Thu, Aug 16, 2018
Calculation Description: Title 24 Analysis
Input File Name: Portofino Remodel -Brock Payton-18.ribdl6x
-PRF-01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
LAWSC'K
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2018-08-16 15:03:14
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted a enforcement gencfor aovyit t,thiuilding permit application.
Responsible Designer Name:
Responsible Designer Signature-
Tim Scott
Company: S
y t
Date Signed:
Scott Design and Title 24, Inc.
2018-08-16 15:03:14
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
VA-4;'.
2
2 1 -
Easy to Verify
at CaICERTS.com
Registration Number: 218-P010233762A-000-000-0000000-0000 Registration Datefrime: 2018-08-16 15:03:14 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-08-16 14:53:18
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Portofino Res Addition
Building Type 10 Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
8/16/2018
Project Address
80-835 Via Portofino La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,433
Addition
170
# of Units
1
INSULATION
Construction Type
Area
Cavity ftz Special Features Status
Roof Wood Framed Attic R 30 5,263 New
Wall Wood Framed R 23 733 Existing
Wall Wood Framed R 23 649 Existing
Wall Wood Framed R 23 628 Existing
Wall Wood Framed R 23 414 Existing
Slab Unheated Slab -on -Grade - no insulation 5,433 Perim = 273' New
Roof Wood Framed Attic R 38 170 Add=R-19.0 Cool Roof New
Wall Wood Framed R 21 63 New
FENESTRATION Total Area. 1.081 Glazing Percentage: 19.9% New/Altered Average U-Factor. 0.30
Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades Status
Left (N) 129.0 0.710
0.60 none none Bug Screen Existing
Rear (E) 213.0 0.710
0.60 none none Bug Screen Existing
Right (S) 234.0 0.710
0.60 none none Bug Screen Existing
Front (W) 448.0 0.710
0.60 none none Bug Screen Existing
Left (N) 57.0 0.300
0.20 2.0 none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
3 Central Furnace 80% AFUE
Split Air Conditioner 16.0 SEER Setback
Altered
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
HVAC 1 Ducted
Ducted Attic 8.0
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Enet:qyRro72bvEnergV23oft User Number 6712
ID:
Page 12 of 26
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Portofino Res Addition
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
811612018
Project Address
80-835 Via Portofino La Quinta
California Energy Climate Zone I Total Cond. Floor Area
CA Climate Zone 15 5,433
Addition
170
# of Units
1
INSULATION
Construction Type
Area
Cavity ftz Special Features
Status
Demising Wood Framed no insulation 1,020
New
FENESTRATION Total Area: 1,081 Glazing Percents w 19.9% NewlAltered Averse U-Factor:
Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades
0.30
Status
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat
Status
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value
Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution
Status
Ene Pro 7.2 by EnerqvSoft User Number: 6712
ID:
Cage 13 of 26
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. *Exceptions may apply.
n4/9017)
Building Envelope Measures:
§ 110.6(a)1:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ftz or less when tested per
NFRC-400 or ASTM E283 or AAMAIWDMAICSA 101/I.S.2IA440-2011 '
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
§ 110.6(b):
110.6-A and 110.E-B for compliance and must be caulked and/or weatherstri ed.'
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
§ 110.7:
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the reauirements of & 110.8 when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a)
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placinq insulation either above or below the roof deck or on top of a drywall ceiling.'
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-
§ 150.0(c):
factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed
value of R-13 in a wood framed assembly.'
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.'
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following; have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration; and when installed as part of a heated slab floor, meet the requirements of § 1%8 .
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
§ 150.0(g)1:
re uirement also applies to controlled ventilation crawl space for buildings complying with the exception to § 150.0(d).
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
§ 150.0(g)2:
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
150.0
§ (q)'
maximum ll-factor of 0.58; or the weighted averse U-factor of all fenestration must not exceed 0.58'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)1A:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
§ 150.0(e)1 B:
and is equipped with a readily accessible operable. and tight -filling dam r or combustion -air control device.'
§ 150.0(e)1C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
§ 150.0(e)2:
the building,are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
§ 110.0-§ 110.3:
a liances must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
§ 110.2(b):
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.*
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
§ 110.2(c):
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculalion loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow, prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)5.
_
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
§ 110.3(c)7:
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btulhr are exem t • and pool and spa heaters'
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)1:
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions s cifled In 150.0 h 2.
a-
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
dry, er vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.'
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve.'
§ 150.06)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
piping for steam and hydronic heating systems or hot water systems must meet the requirements in TABLE 120.3-A.'
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.0Q)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.00)3B:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)1:
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance: and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation (SRCC) or by a listing agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)V
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/< inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such toe is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually aerated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0 m 11 and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of § 150.0 m 12.
2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy15 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced air systems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
§ 150.0(o)1A:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.'
§ 110.4(b)1:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar heatin .
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0
§ (p)
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, of in , filters, and valves!
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of § 110.9.,
§ 110.9(e):
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for
elevated temperature must be installed by final insoection in all recessed downlight luminaires in ceilings.
§ 150.0(k)1 D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors.
§ 150.0(k)1 F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the apDlicable requirements of § 150.0(k).*
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1G:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JAB.'
§ 150.0(k)1 H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturers instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5 ; and meets all other requirements in § 150.0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5 ; and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to § 110.9. and complies with all other applicable requirements in 150.0 k 2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.'
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
a .lcs .
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either § 150.0 k 3A or with the applicable requirements in §§ 110.9. 130.0. 130.2. 130.4.140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0 k 3B or § 150.0 k 3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2. 130.4, 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4.140.7, and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4 140.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
I. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1. 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.1 0b through § 110.1Ole).
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The sdar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the b uildlng excludi aq any sk li ht area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.'
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B.
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical plane'
_
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main servicepanel): and a pathway for routinq of plumbing from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
1 10.10c must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Portofino Res Addition
Date
8/16/2018
System Name
HVAC 1
Floor Area
5,433
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
3
COIL
CFM
Total Room Loads 7,049
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 877
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
I CFM
Sensible
Output per System
89,000
97.728
6,147
1,812
66,439
Total Output Btuh)
267,000
0
Output Btuh/s ft
49.1
5,642
3,265
Cooling System
0
0
Output per System
56,500
32,810
6,450
877
40,538
Total Output Btuh
169,500
268
12,597
-268
Total Output Tons
14.1
5,642
3,265
Total Output Btuh/s ft
31.2
Total Output s ft/Ton
384.6
1 142,090
1 113,239
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
6,000
AC
127,489
30.828
267,000
Alrfiow cfmis ft
1.10
Airflow cfmlTon
424.8
Outside Air %
14.6%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK
127,489
30,828
267,000
LOutside Air cfm/s ft
0.16
: values above given at ARI conditions
Aug 3 PM
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF
Air
877 cfm
69 OF
14 AK
63 OF 105 IF 105 OF
H[Outside
Heating Coil Supply Fan
6,000 cfm
104 OF
ROOM
70 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112 / 78 IF
Outside Air
877 cfm
77/66OF
82 / 68 OF 62 / 61 OF 62 / 61 IF
Cooling Coil Supply Fan
6,000 cfm
63 / 61 IF
—
59.0% ROOM IN
76/66OF
ROOM LOAD SUMMARY
Project Name Date
Portofino Res Addition 811612018
System Name Floor Area
HVAC 1 5,433
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
Existing Existing Res. 1 6,887 95,645 5,943 6,887 95,645 5,943 1,787 65,447
Addition Res. Addition 1 1621 2,083 204 1621 2,083 204 26 992
PAGE TOTAL
TOTAL*
7.049
97,728 6,147
1,812
66,439
7,049
97,7281 6,147
1,812
66,439
* Total includes ventilation load for zonal
ROOM HEATING PEAK LOADS
Project Name
Portofino Res Addition
Date
8/16/2018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Existing Res.
Floor Area 5,263.00 ft2
Indoor Dry Bulb Temperature 70 °F
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
AT °F
c
=
=
c
=
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
44
Btu/hr
R-30 Root
5,263.0
0.0310
X
X
44
7,179
R-19 Wad
2,424.0
0.0670
44
7,146
Existing Window
1,024.0
0.7100
0.7300
X
44
31,990
Slab -On -Grade
perim = 261.0
X
lX
lX'
IXi
44
8,383
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (") denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 5,263 X
Area
another room
10.00 X 0.262
Height ACH
Page Total
/ 60 J X
AT
54,698
= 10,749
TOTAL HOURLY HEAT LOSS FOR ROOM 65,447
ROOM HEATING PEAK LOADS
Project Name Date
Portofino Res Addition 8/16/2018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Res. Addition
Floor Area 170.00 ftZ
Indoor Dry Bulb Temperature 68 °F
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
x
x
x
x
x
X
X
X
X
X
X
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
to
Ceiling
U-Value
x
x
x
x
x
X
X
X
X
X
X
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
AT °F Btu/hr
42 = 124
42 = 183
42 = 716
-2 = -726
42 = 368
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Page Total 667
/ 60 ] X 42 = 326
❑T
R-38 Roof w1 R19
170.0
0.0174
R-21 Wall
63.0
0.0690
.30.20
57.0
0.3000
'R-0 Interior Wall
1,020.0
0.3560
Slab -On -Grade
pen .m = 12.0
0.7300
Items shown with an asterisk (") denote conduction
Infiltration:[ 1.00 x 1.064
Schedule Air Sensible
Fraction
through an interior surface
x 17D x
Area
another room
10.00 xF 0.257
Height ACH
TOTAL HOURLY HEAT LOSS FOR ROOM 992
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Portofino Res Addition 811612018
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Existing Res.
Outdoor Dry Bulb Temperature
112 OF
Floor Area
5,263.00 ftz
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
76 OF
Outdoor Daily Ranee:
34 OF
Opaque Surfaces
R-30 Roof
R-19 Wall
R-19 Wall
R-19 Wall
R-19 Will
Orientation
(N)
(N)
(E)
(s)
(W)
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
x
X
X
X
CLTD'
=
=
=
=
=
=
=
=
5,263.0
0.0310
56.0
733.0
0.0670
23.0
649.0
0.0670
33.0
628.0
0.0670
26.0
414.0
0.0670
33.0
[
Page Total
Items shown with an asterisk (") denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
Ex Window
Ex Window
Ex Window
Ex Window ----
Ex Window
Ex Window
Ex Window
Ex Window
Ex Window
Internal Gain
❑riantatinn
(N)
(N)
(N)
(N)
(E)
(E)
(E)
(E)
(E)
Shaded Unshaded
Btu/hr
9,137
1,130
1,435
1,094
915
1 13,7101
Area
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
GLF
e
=
=
=
=
e
=
=
0.0
36.5
48.0
36.5
0.0
36.5
48.0
36.5
0.0
36.5
16.5
36.5
0.0
36.5
16.5
36.5
0.0
36.5
1.0
72.1
0.0
36.5
1.0
72.1
0.0
36.5
1.0
72.1
0.0X
36.5+
48.0X
72.1=
72.1
0.0
36.5
48.0
Page Total
15.8 Occupants X 245 Btuh/occ.
5,263 Floor Area X 0.50 w/sgft --
Infiltration: 1.064 X 0.88 X 241.19 X 36 _
Air Sensible CI=M ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain
15.8 Occupants X 155 Btuh/occ.
Infiltration: 4,771 X 0.88 X 241.19 X 0.00344
Air Latent CFM ELA AW
Btu/hr
1,750
1,750
602
11,841
Btu/hr
3,858
8,981
8,166
95,645
Btu/hr
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM Z447I
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Portofino Res Addition 8/16/2018
ROOM INFORMATION DESIGN CONDITIONS
Room Name Existing Res. Outdoor Dry Bulb Temperature 112 OF
Floor Area 5,263.00 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 76 OF, Outdoor Daily Range: 34 OF
I Opaque Surfaces
Orientation
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
Page Total
Items shown with an asterisk (") denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
Ex Window
Ex Window
Ex Window
Ex Window
Ex Window
Ex Window
Ex Window
Ex Window
Ex Window
Internal Gain
Orientation
(E)
(E)
(E)
(E)
(S)
(S)
(S)
(S)
(S)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
-
0.0
36.5
48.0
72.1
0.0
36.5
15.0
72.1
0.0
36.5
15.0
72.1
0.0
36.5
36.0
72.1
0.0
36.5
6.0
36.6
0.0
36.5
6.0
36.6
0.0
36.5
1.0
36.6
0.0
36.5
1.0
36.6
0.0
36.5
36.0
36.6
Page Total
15.8 Occupants X 2451 Btuh/occ.
5,263 Floor Area X 0.501 w/sgft =
Infiltration: 1.064 X 0.88 X 241.19 X 36 =
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain
15.8 Occupants X 1 155 Btuh/occ. _
Infiltration: I X 0.88 X 241.19 X 0.00344 =
Air Latent CFM ELA AW
Btu/hr
0
Btu/hr
3,460
1,081
1,081
2,595
220
220
37
37
1.318
10,04
Btu/hr
3.868
8.961
8.166
95.645
Btu/hr
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,4471
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Portofino Res Addition
811612018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Existing Res.
Outdoor Dry Bulb Temperature
112 OF
Floor Area
5,263.00 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 °F
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
X
XI
=
X
X�
_
X
X1
=
X
X1
=
X
X�
_
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area GLF
Btulhr
Ex Window
(S) 0.0 X 36.5 +
1.0 X
36.6 =
37
Ex Window
(S) 0.0 X 36.5 +
6.0 X
36.6 =
220
Ex Window
(S) 0.0 X 36.5 +
48.0 X
36.6 =
1,757
Ex Window
(S) 0.0 X 36.5 +
96.0 X
36.6 =
3,514
Ex Window
(S) 0.0 X 36.5 +
16.5 X
36.6 =
604
Ex Window
(S) 0.0 X 36.5 +
16.5 X
36.6 =
604
Ex Window
(W) 0.0 X 36.5 +
96.0 X
72.1 =
6,920
Ex Window
(W) 0.0 X 36.5 +
160.0 X
=
11,534
Ex Window
(W) 0.0 X 36.5 +
96.0 X
V2.1
=
6,920
Page Total
32,110
Internal Ga€n
Btulhr
Occupants
15.8 Occupants X 245
Btuh/occ.
-
L:A
Equipment
5,263 Floor Area X 0.50
w/sgft
Infiltration: 1.064
X 0.88 X 241.19 X 36
6.166
Air Sensible
CFM ELA 1T
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
95.645
Latent Gain
Btu/hr
Occupants
15.8 Occupants X 155
Btuh/occ.
_
2,447
Infiltration: 4,771
X 0.88 X 241.19 X 0.00344 =
3,495
Air Latent
CFM ELA AW
TOTAL HOURLY LATENT
HEAT GAIN FOR ROOM
2,447
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Portofino Res Addition
8/16/2018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Existing Res.
Outdoor Dry Bulb Temperature
112 OF
Floor Area
5,263.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF
Outdoor DailM Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
Page Total
0
Items shown with an asterisk (")
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GI.F
Area GLF
Btu/hr
Ex Window
(W) 0.0 X 36.5 +
48.0 X 72.1 =
3.460
Ex Wrndow
(W) 0.0 X 36.5 +
48.0 X 72.1 =
3,460
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
Page Total
6,920
Internal Gain
Occupants
15.8 Occupants X 245
Btuh/occ. =
Btulhr
3.868
Equipment
5,263 Floor Area X 0.50
w/sgft
Infiltration: 1.064
X 0.88 X 241.19 X 36 =
8,166
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
95,645
Latent Gain
Btu/hr
Occupants
15.8 Occupants X 155
Btuh/occ. =
2,447
Infiltration: 4,771
X 0.$8 X 241.19 X 0.00344 =
3,495
Air Latent
CFM FLA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
2,447
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Portofino Res Addition
1 811612018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Res. Addition
Outdoor Dry Bulb Temperature
112 OF
Floor Area
170.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF
1 Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor CLTD'
Btu/hr
R-38 Roof w1 R19
(N) 170.0 X 0.0174 X 56.0 =
166
R-21 Wall
(N) 63.6 X 0.0690 X 23.0 =
100
'R-0 Interior Wall
1,020.0 X 0.3560 X 1.0 =
363
X X =
X X =
X X =
X X =
X X =
X X =
Page Total
629
Items shown with an asterisk (")
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded Unshaded
Fenestration
Orientation Area GLF Area GLF
Btu/hr
New Window
� (N) 0.0 X 13.4 + 16.5 X 13.4
= 221
New Window
(N) 0.0 X 13.4 + 24.0 X 13.4
= 322
New Window
(N) 0.0 X 13.4 + 16.5 X 13.4
= 221
X + X
=
X + X
=
X + X
=
X + X
=
X + X
=
X + X
=
Page Total
7G5
Internal Gain
Btu/hr
Occupants
245
0.5 Occupants X 245 Btuh/occ,
125
Equipment
170 Floor Area X w/sgft =
290
Infiltration: 1.064
X 0.69 X 7.79 X 37 =
274
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
2,083
Latent Gain
Btu/hr
Occupants
0 5 Occupants X 155] Btuh/occ. =
79
Infiltration: 4,771
X 0.89 X 7.79 X 0.00376 T
125
Air Latent
CFM i_LA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
79