BRES2018-0291U� VOICE (760) 777-7125 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 9/17/2018 Permit Type/Subtype: BUILDING RESIDENTIAL/REMODEL Owner: Application Number: BRES2018-0291 GARY PRAVORNE Property Address: 79780 RANCHO LA QUINTA DR APN: 602210019 92253 Application Description: PRAVORNE / GOLF CART GARAGE CONVERSION Property Zoning: Application Valuation: $5,000.00 Applicant: D Contractor: RISEN CONSTRUCTION RISEN CONSTRUCTION 82-775 CHARLESTON AVE SEP 17 2018 82-775 CHARLESTON AVE INDIO, CA 92201 INDIO, CA 92201 CITY OF LA QUINTA (760)347-6399 DESIGN &DEVELOPMENT DEPARTMENT Llc. No.: 792381 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 792381 +tom I IrQ Conttr: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Add WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the Pfor which this permit is issued. I have and will maintain workers' compensation insurance, as required by Sectoon 3700 of the Labor Code, For the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 9066905 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith i comply with those provisions. 7//71le Aoclirant: WARNING: FAILURE FAILURE TO SECURE WORKERS' CMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city t nter upon th above -mentioned property for inspection purposes. /� Date: 9/47/201;5 Application Number: BRES2018-0291 Owner: Property Address: 79780 RANCHO LA QUINTA DR GARY PRAVORNE APN: 602210019 Application Description: PRAVORNE / GOLF CART GARAGE CONVERSION 92253 Property Zoning: Application Valuation: $5,000.00 Applicant: RISEN CONSTRUCTION 82-775 CHARLESTON AVE INDIO, CA 92201 Contractor: RISEN CONSTRUCTION 82-775 CHARLESTON AVE INDIO, CA 92201 ! (760)347-6399 Llc. No.: 792381 --------------------------------------------------------------------------------------------- Detail: CONVERSION OF GOLF CART GARAGE BACK TO OFFICE SPACE 13AF. EXISTING MECHANICAL, ELECTRICAL, AND PLUMBING TO REMAIN UNALTERED. THIS PERMIT DOES NOT INCLUDE ANY ALTERATIONS TO THE RESVOF THE EXISITNG DWELLING. 2016 CALIFORNIA BUILDING CODE. DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT Credit Card Fee 101-0000-43505 0 $2.25 DESCRIPTION ACCOUNT CITY AMOUNT Credit Card Fee 101-0000-43505 0 $6.38 Total Paid for Credit Card Fee: $8.63 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $26.01 Total Paid for ELECTRICAL: $52.02 DESCRIPTION ACCOUNT CITY AMOUNT PLAN CHECK DEPOSIT - ADDITION/REMODEL 101-0000-42600 1 $125.00 Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00 DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($53.05) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($71.95) DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, FIRST 100 SF 101-0000-42400 0 $53:05 DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 0 $71.95 DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 0 $73.17 Total Paid for REMODEL: $73.17 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $0.65 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.65 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT CITY AMOUNT DOOR/WINDOW, NEW/ALT, FIRST 1 101-0000-42400 0 $104.03 DESCRIPTION ACCOUNT CITY AMOUNT DOOR/WINDOW, NEW/ALT, FIRST 1 PC 101-0000-42600 0 $118.59 Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $222.62 40c (2";Wra PERMIT # [� PLAN LOCATION: Project Address: ! ¢i7 ��+� l ► { Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: a 0 �- Applicant Name: t Address: 92-. 5- City, ST, Zip: 5:;f Oi Telephone: Email: Valuation of Project $ QQ Contractor Name: New SFD Construction: Address: Conditioned Space SF City, St, Zip Garage SF Telephone: Patio/Porch SF Email: Fire Sprinklers SF State Lic: 792 3 I City Bus Lic: Arch/Eng Name: Construction Type: Occupancy: Address: I '7 Grading: City, St, ru Zip/A&P._ Telephone: _ O Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: pl-Avof" New Commercial / Tenant Improvements: Address: _ Total Building SF City, ST, Zip Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QU I NTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal Req'd Rec'd Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License CERTIFICATE OF COMPLIANCE Desert Sands Unified School District cy 10o 47950 Dune Palms Road t;t: Date: 9/17/2018 La Quinta, CA 92253 Y 1Y37pH SVL3 l^e y` No.: 18-01112-1 (760)771-8515 �yOl. A QL�LViA �.7� • Owner: Gary Pravorne Email: Address: 82-775 Charelston Ave Jurisdiction: Indio City: Indio Tract #: Type: Residential Addition < 500 sq ft Lot # Street No. Street Name Sq. Feet 79-780 Rancho La-Quinta 132 RECEIVED SEP 17 2018 CITY OF LA QUINTA Comments: COMMUNITY DEVELOPMENT APN Permit No. 602-210-019 At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. it has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less Exempt This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 132 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: Exempt "S�i Check No.: Bank Name/Recipient of Certificate Telephone: 760-485-5750 Funding: Exempt By Scott L. Bailey Superintendent Fee Collected/ Exempted by: Arianne Catano Certificate Fees Due: $0.00� Original Payment(s) Rec'd: $0.00 New Payment Rec'd: $0.00 Over/Under: $0.00 NOTICE: Pursuant to Government Code section 66020(d)(1), this will serve to notify you that the 90-(I, y approval period in which you may protest the fe Ps or other payment identified above will begin to run from the date on which the building or installation permit for this project is istuf d, or from the data on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. cl-T I BUILDING ENERGY ANALYSIS REPORT 1 (3�s 20 t $- o 2--9 1 PROJECT: Pravorne 132 s.f. Addition 79-780Rancho La Quinta Dr. La Quinta CA 92253, Project Designer: Paul Nelson / 760-508-3400 Report Prepared by: David Elliott Energy Services 9013 SVL Box Spring Valley Lake, CA, 92395 760.243.3883 CITY OF �J�I QUINTA Job Number: ii'i ,' `` F , I V E D I BUILDING DIVISION 18-08-060 REVIEWED FOR AUG 2 3 2018 CODE COMPLIANCE Date: CITY OF LA QUINTA ❑AiE2` 1f f ItI98Y 8/20/2018 COMMUNITY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software—www.energysoft.com. 10 STATE OF CALIFORNIA Aft Prescriptive Residential Additions That Do Not Require HERS Field Verification GEC-CFIR-ApR•px-E iovinvd 077171 CAUFORWA SNERGY COMMISSION CERTIFICATE OF COMPLIANCE CFIR-ADD-02-E Prescriptive Residential Additions That Do Not Require HERS Field Verification (Page 1 of 9) Pr.1-N.— Pravorne 132 &L Addition Dace Prap—d: 8/20/2018 This compliance document is only applicable to additions less than 1,000 ft`and do not require HERS field verification for compliance. When HERS verification is required, a CF1R-A0D-01 shall first be registered with a HERS Provider Data Registry. Alterations to Space Conditioning Systems that are exempt from HERS verification requirements may use the CF1R-ADD-02 and CF1R-ADD-02 Compliance Documents. Possible exemptions from duct leakage testing include: less than 40 ft of ducts were added or replaced; or the existing duct system was insulated with asbestos; or the existing duct system was previously tested and passed by a HERS Rater. If space conditioning systems are altered and are not exempt from HERS verification, then a CF1R-ADD-01 must be completed and registered with a HERS Provider Data Registry. Additions or alterations that utilize close Cell Spray Polyurethane Foam (ccSPF) with a density of 1.5 to less than 2.5 pounds per cubic foot having an R-value other than 5.8 per inch, or Open Cell Spray Polyurethane Foam (ocSPF) with a density of 0.4 to less than 1.5 pounds per cubic foot having an R-value of 3.6 per inch, shall complete and register a CF1R ADD-01 with a HERS Provider Data Registry. If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they are responsible. Alternatively, the person with chief responsibilityfor construction shall prepare and sign this certificate for the entire construction. All applicable Mandatory Measures shall be met. Temporary labels shall not be removed before verification by the building inspector. A. General Information 01 Project Name: Pravorne 132 s.f. Addition 02 Date Prepared: 8/20/2018 03 Project Location: 79-780Rancho La Quinta Dr. 04 Building Front Orientation (deg): (S) 180 deg 05 CA City: La QUlnta CA 92253 06 Number of Dwelling Units with Additions: 1 07 Zip Code: 08 Fuel Type: Natural Gas 09 Climate Zone: 15 10 Total Conditioned Floor Area (ft') (Addition): 132.0 11 Building Type: Single Family 12 Slab Area(ft'): 132 13 Project Scope: Addition: CFA = 132.0 sqft 14 Exceptions to Fenestration U-factor and SHGC 150.1 c 3A: CA Building Energy Efficiency Standards - 2016 Residential Compliance July 2017 STATE OF CALIFORNIA Prescriptive Residential Additions That Do Not Require HERS Field Verification CERTIFICATE OF COMPLIANCE Prescriptive Residential Additions That Do Not Require HERS Field Verification YfefPC .— Pravorne 132 s.f. Addition CALIFORMA ENEROY COMMISMN CF1R-ADD-02-E (Page 2 of 9) Dale Prepared:8/20/2018 B. Opaque Surface Details — Framed (Section 150.2(a)) 01 02 03 04 05 06 07 08 09 10 11 Tag/ID Assembly Type Frame Type Frame Depth (inches) Frame Spacing (inches) Proposed Re ulred Comments Cavity R-value Continuous Insulation R-value U-Factor Appendix JA4 Reference U-Factor or R-value Table Cell 1 Roof Wood 2x4 @ 4 in. O.C. 30 0.0 0.031 4.2.1 -A20 0.043 Altered R-30 Roof Attic 2 Wall Wood 2x4 @ 6 in. O.C. 13 0.0 0.102 4.3. -A3 0.102 Exist'g R-13 Wall w11" EPS 3 Wall Wood 2x4 @ 6 in. O.C. 13 0.0 0.102 4.3. -A3 0.102 Exist'g R-13 Wall w/1" EPS 4 Wall Wood 2x4 @ 6 in. O.C. 13 0.0 0.102 4.3. -A3 0.102 Exist'g R-13 Wall w/1" EPS CA Building Energy Efficiency Standards - 2016 Residential Compliance July 2017 STATE OF CALIFORNIA Prescriptive Residential Additions That Do Not Require HERS Field Verification CERTIFICATE OF COMPLIANCE Prescriptive Residential Additions That Do Not Require HERS Field Verification Pf.Jod N.m. Pravorne 132 s.f. Addition 8/20/2018 WISSION 0 CF1R-ADD-02-E (Page 3 of 9) C. Opaque Surface Details — Non -framed (Section 150.1(c)1) 01 02 03 04 05 06 07 1 08 1 09 10 11 Tag/ID AssemblyType Assembly Materials Thickness (inches) Pro osed Required Comments Core Insulation R-value Continuous Insulation R-value U-Factor AppendixJA4 Reference U-Factor from Package Table I Cell D. Opaque Surface Details — Mass Walls (Section 150.1(c)1) 01 02 03 04 05 06 07 08 j 09 10 11 Tag/ID Walls Above Grade Mass Type Mass Thickness (inches) Furring Strip Thickness (inches) Proposed Required Interior Insulation Exterior Insulation Appendix JA4 Reference Interior Insulation Exterior Insulation R-value U-factor R-value U-factor Table Cell R-value U-factor R-value U-factor CA Building Energy Efficiency Standards - 2016 Residential Compliance July 2017 STATE OF CALIFORNIA Prescriptive Residential Additions That Do Not Require HERS Field Verification a GLK.Ia- I KAOOAE-E M&A6nA 07117 CAI.JFORNIA ENERGY COMMIS§10N CERTIFICATE OF COMPLIANCE CF1R-ADD-02-E Prescriptive Residential Additions That Do Not Require HERS Field Verification (Page 4 of 9) Pravorne 132 s.f. Addition Date Prepared: 8/20/2018 E. Slab Insulation (Table 150.1-A) 01 02 03 04 05 06 Floor Type Pro osed Re uired Comments Insulation R-value Insulation U-factor Insulation R-value Insulation U-factor Unheated Slab -on -Grade 0 0.730 Note: y Heated slab floors require mandatory slab insulation (see Table 110.8-A). F. Radiant Barrier (Section 150.1(c)2) 01 02 Radiant Barrier installed below the roof deck and on all gable end walls Comments All New Roof areas with Attics Radiant Barrier required in this Climate Zone A radiant barrier Is required (for Climate Zones 2-15) • Radiant barriers shall meet specific eligibility and installation criteria to receive energy credit for compliance with the Building Energy Efficiency Standards for low-rise residential buildings. Refer to RA4.2.1 • The emittance of the radiant barrier shall be less than or equal to 0.05 as tested in accordance with ASTM C1371 or ASTM E408. • For Prescriptive Compliance the attic shall be ventilated to provide a minimum free ventilation area of not less than one square foot of vent area for each 300 ft2 of attic floor area with no less than 30 percent upper vents. Ridge vents orgable end vents are recommended to achieve the best performance. The material should be cut to allow for full airflow to the venting. CA Building Energy Efficiency Standards - 2016 Residential Compliance July 2017 STATE OF CALIFORNIA Prescriptive Residential Additions That Do Not Require HERS Field Verification CERTIFICATE OF COMPLIANCE Prescriptive Residential Additions That Do Not Require HERS Field Verification Pravorne 132 s.f. Addition Date Prepared; 8/20/2018 MMISSION CF1R-ADD-02-E (Page 5 of 9) G. Roofing Products (Cool Roof) (Section 150.1(c)11) 01 02 03 04 05 06 07 08 09 10 11 12 Mass Roof 25lb/ft2or Greater Roof Pitch Method of Compliance Product Type CRRC Product ID Number Proposed Required Initial Solar Reflectance Aged Solar Reflectance Thermal Emittance SRI (Optional} Aged Solar Reflectance Thermal Emittance SRI (Optional) Notes: • Any roof area covered by building integrated photovoltaic panels and solar thermal panels are exempt from the above Cool Roof requirements. a Liquid field applied coatings must comply with installation criteria from section 110.8(i)4. H. Fenestration/Glazing Allowed Areas and Efficiencies (Section 150.2(a)1) 01 02 1 03 04 1 05 06 07 08 09 10 Maximum Allowed Maximum Allowed Fenestration Area for All West -Facing Fenestration Orientations ftZ Area Only ftZ Maximum Maximum Maximum Maximum The Greater The Greater Addition Allowed Allowed Allowed Allowed Type ftZ U-factor U-factor SHGC SHGC Comments Maximum Maximum Calculated Maximum Calculated Maximum (Windows) (Skylights) (Windows) (Skylights) based on Calculated based on Calculated Allowed ftZ Allowed ftZ Allowed % Allowed % 132.0 1 39.6 75.0 60.0 60.0 0.320 0.550 0.250 0.300 Skylight Exception <= 16 sgft CA Building Energy Efficiency Standards - 2016 Residential Compliance July 2017 STATE OF CALIFORNIA Prescriptive Residential Additions That Do Not Require HERS Field Verification aaa.ocr�nu CERTIFICATE OF COMPLIANCE CF1R-ADD-02-E Prescriptive Residential Additions That Do Not Require HERS Field Verification (Page 6 of 9) PfOfe""ame: Pravorne 132 s.f. Addition D.I. Pre,"etl: 8/20/2018 I. Fenestration Proposed Areas and Efficiencies Note: If meeting Exception 1 to 150.1(c)3A, Installing <_ 3ft2 glass in door, it is assumed to meet the minimum required U-factor (0.32) & SHGC (0.25). If meeting Exception 1 to 150.1 c 3A, Installing < 3ft2 tubular skyli ht, it is assumed to meet the minimum required U-factor (0,55) & SHGC (0.30). 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Tag/1 D Fenestration Type Frame Type Dynamic Glazing Orientation N,S, W, E Number of Panes Proposed Fenestration z Area ft Proposed West Facing Fenestration Area ftz Proposed U-factor Source Proposed SHGC Source Exterior Shading Device Combined SHGC from CF1R-ENV-03 1 New Non -Metal (W) 2 29.8 29.8 0.320 NFRC 0.25 NFRC n/a 0.25 2 Altered I Non -Metal (W) 2 29.8 29.8 0.320 NFRC 0.25 NFRC I n/a 0.25 15 Total Proposed Fenestration Area 59.6 16 Maximum Allowed Fenestration Area 75.0 17 Compliance Statement I Total Proposed Fenestratlon Area 5 Maximum Allowed Fenestration Area ❑ Yes ❑ No 18 Total Proposed West -Facing Fenestration Area 59.6 19 Maximum Allowed West -Facing Fenestration Area 60.0 20 Compliance Statement I Total Proposed West -Facing Fenestration Area 5 Maximum Allowed West -Facing Fenestration Area ® Yes ❑ No 21 Proposed Fenestration U-factor (Windows) 0.320 22 Required Fenestration U-factor (Windows) 0.320 23 Compliance Statement I Proposed Fenestration U-factor 5 Required Fenestration U-factor ❑ Yes ❑ No 24 Proposed Fenestration SHGC (Windows) 0.250 25 Required Fenestration SHGC (Windows) 0.250 26 Compliance Statement I Proposed Fenestration SHGC 5 Required Fenestration SHGC d Yes ❑ No 27 Proposed Fenestration U-factor (Skylights) 0.000 28 Required Fenestration U-factor (Skylights) 10.550 29 Compliance Statement Proposed Fenestration U-factor < Required Fenestration U-factor m Yes ❑ No 30 Proposed Fenestration SHGC (Skylights) 0.000 31 Required Fenestration SHGC (Skylights) 0.300 32 Compliance Statement Proposed Fenestration SHGC as Required Fenestration SHGC ® Yes ❑ No CA Building Energy Efficiency Standards- 2016 Residential Compliance July 2017 STATE OF CALIFORNIA Prescriptive Residential Additions That Do Not Require HERS Field Verification CEC-CFSR•A00•02•E Revi6ed 07117 CALIFORNIA ENERGY COMMISSION 10 CERTIFICATE OF COMPLIANCE CF1R-ADD-02-E Prescriptive Residential Additions That Do Not Require HERS Field Verification (Page 7 of 9) Prq—N— Pravorne 132 s.f. Addition DNePRpnd 8/20/2018 J. Space Conditioning (SC) Systems — Heating/Cooling (Prescriptive Section 150.2(b)) Alterations to Space Conditioning Systems shall be exempt from HERS verification requirements as prerequisite for use of the CF1R-ADD-02 and CF2R-ADD-02 Compliance Documents. If new space conditioning systems are installed or existing systems are altered and are not exempt from HERS verification, then a CF1R-ADD-01 shall be completed and registered with a HERS Provider Data Registry. In each row below for each dwelling unit in the building, check the box that indicates the exemption from HERS verification compliance: ❑ a: space conditioning system was not altered; ❑ b: less than 40 ft of ducts were added or replaced; ❑ c: (exempt from duct leakage testing) if: the existing duct system was insulated with asbestos; ❑ d: {exemptfrarn duct leakage testing) if: the existing duct system was previously tested and passed by a HERS Rater. 01 02 03 04 Dwelling Unit Name SC System Identification or Name SC System Location or Area Served Exemption from HERS Verification Addition Existing 2-1/2 Ton A.C. 132 IZI a ❑ b ❑ c ❑ d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d El ❑b ❑c ❑d ❑a El ❑c ❑d CA Building Energy Efficiency Standards - 2016 Residential Compliance July 2017 STATE OF CALIFORNIA Prescriptive Residential Additions That Do Not Require HERS Field Verification CERTIFICATE OF COMPLIANCE Prescriptive Residential Additions That Do Not Require HERS Field Verification PfOf.dN. Pravorne 132 s.f. Date Pmpared:8/20/201 8 iVAIS8k]N CF1R-ADD-02-E (Page 8 of 9) K. Water Heating Systems (Section 150.2(a)1D) List water heaters and boilers for both domestic hot water (DHW) heaters and hydronic space heating. 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Dwelling Unit Name Water Heating System Identification or Name Water Heating System Location or Area Served Water Heating System Type Water Heater Type a of Water Heaters in System Water Heater Storage Volume al Fuel Type Rated Input Type Rated Input Value Heating Efficiency Type Heating Efficiency Value Standby Loss M) Exterior Insulation R-Value Back -Up Solar Savings Fractlon CA Building Energy Efficiency Standards - 2016 Residential Compliance July 2017 STATE OF CALIFORNIA AWL Prescriptive Residential Additions That Do Not Require HERS Field Verification CEC•CFIR•AOO.02•E "Bed07/17 — - _. _ CALWORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE Prescriptive Residential Additions That Do Not Require HERS Field Verification Pravorne 132 s.f. Addition UUI.0 IVI EN I A I WIN N AUTNI STATEMENT _ CF1R-ADD-02-E (Page 9 of 9) Data Prepared: 8/20/2018 1. 'certify that this Certificate of Compliance documentation isaccurate and com ate. Documentalion Author Name: Documentation Avowslynstuw. Company: David Elliott Energy Services Signature Date: 8/20/2018 — Address: 9013 SVL Box CEA/ HERS Certification Identification (if applicable): citvAtalonip; Phone: Spring Valley Lake, CA, 92395 760.243.3883 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand thata registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at OCCupaOCy. Responsible Dessner Name; ResponsiWr Designer Signature: Company: Date Signed: Paul Nelson / 760-508-3400 Address: .. ...... Phone. For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300. CA Building Energy Efficiency Standards - 2016 Residential Compliance July 2017 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply, (Revised 04120171 Building Envelope Measures: § 110.6(a)l: Air Leakage, Manufactured fenestration, exterior doors, and exterlor pet doors must limit air leakage to 0.3 cfmlftl or less when tested per NFRC-400 or ASTM 1«283 or AAMAIWDMAICSA 10l/I.S.2/A440-2011; § 110,6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-13 for compliance and must be caulked andlor weathersUi ed.' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped, § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance, The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8 i when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0,043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a clumall ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturers required density for the labeled R-value. Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U- § 150.0(c): factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.' § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab Boor, meet the requirements of.4 1 10.8. 150 0 1 (g) : Vapor Retarder, In Climate Zones 1.16, the earth Poor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This re uirement also.Mlles Iles to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d). § 150.0(g)2; Vapor Retarder, In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls vented attics and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58: or the wei hied averse U-factor of all fenestration must not exceed 0,58,' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)1 B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square Inches in area and is equipped with a readily accessible, ❑ erable and tght-fittinn damper or combustion -air control device.' § 150.0(e)l C: Flue Damper, Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the buildin , are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0 § 190.3: Certiflcatlon. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances muss be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110,2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters, Heat pumps with supplementary electric resistance heaters § 110,2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for su lementa healing.' § 110.2(c): - Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have -a setback thermostat! Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 1113.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6,8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply volts a connection with pilot li hts that consume less than 150 Btulhr are exempt); and pool and spa heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions specified in § 150.0(h)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: _ Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1. Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation, For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A; nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures,' § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corperalion SRCC or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must cerlf to the customer, in writing, that the insulation meets this re uirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603,0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/< inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is -used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for; pressure -sensitive tapes, mastics sealants, and other requirements s ecified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers, § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openinds to the outside, except combustion inlet and outlet airopenings.,and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier, Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m 11 and Reference Residential Appendix RA3. Air Filtration, Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150,0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of § 150.0 m 12. 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow a 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced air ms.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of rovidin whole-bui ding ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing,in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.' § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover, § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or 2rogrammed to run only during off- eak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.' § 110.9(e): JAB High Efficacy Light Sources. To qualify as a JAB high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JAB. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1 C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the a licable requirements of 150.0 k .' Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 ; and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 ; and all other requirements in § 150.0(k)2. § 150.0(k)2I: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it -provides the functionality of a dimmer according to § 110.9 and complies with all other applicable requirements in § 150.0 k 2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls, In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K; Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.* § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMC5. Residential Outdoor Lighting, For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0 k 3A or with the applic&e requirements in §§ 110.9,130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B or § 150.0 k 3D must comply with the applicable requirements in §§ 110.9, 130.0 130.2 130.4 140.7 and 141.0. § 150.0(k)3O: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must com I with the applicable re uirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined accordin to § 130.0(c). § 150.0(k)5: Residentlal Garages for Eight or More Vehicles, Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential ara es in 110.9, '130.0,130.1. 130.4 140.E and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.1 0b through § 110.10 e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below, The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skyli ht area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted a ui ment.' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.` § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clear!y indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 110.1 0c must be provided to the occupant, § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric'. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Pravorne 132 s.f. Addition Date 8/20/2018 System Name Existing 2-1/2 Ton A.C. Floor Area 132 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 170 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 40,000 3,579 158 109 4,024 Total Output Btuh 40,000 0 Output Btuh/s ft 303.0 207 198 Coolin S stem 0 0 Output per System 30,000 01 0 0 0 Total Output Btuh 30,000 0 158 0 Total Output Tons 2•5 207 198 Total Output Btuh/s ft 227.3 Total Output s ftrron 52.8 r 3,993 14,420 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Existing 2-1/2 Ton A.C. 25,209 0 40,000 Airflow cfm/s ft 9•09 Airflow cfm/Ton 480.0 25,209 0 40,000 Jan 1 AM Outside Air % 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Outside Air cfm/sgft 0.00 Note: values above given at ARI conditions I Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 26 IF 70 IF Outside Air 0 cfm Supply Fan 1,200 cfm 70 IF 70 IF 105 IF Heating Coil f 105 OF ROOM - 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak) 112 / 78 IF 75 / 61 IF 75 / 62 IF 55 / 54 IF Outside Air a 0 cfm Supply Fan Cooling Coil 1,200 cfm 75 / 61 IF I 55 ! 54 OF - • �.7 46.3 % ROOM - - 75 / 61 OF ADDRESS 90 VA o Li APPLICATION �-� W rg- PROJECT DESCRIPTION I,IV --S t U 0 New Construction CONDITIONED/AC (SF) GARAGEWNCOND (SF) PATIO/COVERED (SF) FIRE SPRINKLER (SF) /RR DITIO N E OOD YES / NO LOORS ROOMSF UNITSTLOADPANCY/ACRE) (DWELLING UNITS PER ACRE, EX: 43,5rASFf?.000SF 1-01 = 6.22DUlACRE) Remodel/Addition REMODEL AREA (SF) ADDITION AREA (SF) AWNING/CANOPY (EA) BALCONY ADDITION (EA) FIREPLACE (EA) PARTITION (EA) STUCCO APPLICATION (SF) DOOR/WINDOW - REP (EA) DOOR/WINDOW - NEW (EA) Z� CARPORT (EA) VALUATION ($) (AS SHOWN ON BUILDING APPLICATION) Grading TRACT ❑ CUSTOM HOME <=7KSF ❑ CUSTOM HOME >7KSF 'Q, VALID UNITL DATE Mechanical FURNACE HEATER APPLIANCE (ALT/ADD) COMPRESSOR AIR HANDLER EVAP COOLER VENT FAN EXHAUST HOOD MISC MECHANICAL Units Electrical Units NEW ELECTRICAL (SF) and/or _ RECEP/SWITCH/LIGHT plus APPLIANCE - RES APPLIANCE - NONRES POWER APPARATUS SIGNS SERVICE TEMPORARY SERVICE MISC ELECTRICAL LIGHT POLES PV SYSTEM - ARRAY PV SYSTEM - MISC EQ Plumbing Units FIXTURE/TRAP SEWER SEPTIC ROOF DRAIN WATER HEATER GREASE INTERCEPTOR WATER PIPING BACKFLOW GAS OUTLETS REVISED:7/15/2015 RESIDENTIAL Unit Counts TOILETS BIDET/URINAL SHOWERS BATHTUBS SINKS BAR SINK BBQ OVEN RANGE COO KTO P DRINKING FOUNTAIN WASHER ` DRYER WATER HEATER ROOF DRAINS FLOOR DRAINS KITCHEN SINK VEGGIE SINK LAUNDRY SINK FIREPLACE Qty REVISED: 7/15/2015 RESIDENTIAL