BWFE2018-010978-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type/Subtype:
Application Number:
Property Address:
APN;
Application Description:
Property Zoning:
Application Valuation:
c&ty/ 4 e(F Quiam
DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
WALL/FENCE/CITY STANDARD/PRE-APPROVED
BWFE2018-0109
81710 WAR ADMIRAL
767800033
GRIFFIN RANCH / BLOCK WALL 192 LF / LOT 108
$6,550.00
Applicant:
LENNAR HOMES -SHELLYJORDAN
980 MONTECITO DR STE 300
CORONA, CA 92879
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 70001 of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: License No.: AEC674
Date:Z�� �� Ccntrettpr.
OWNER -BUILDER DECLARATIO
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. B.&P.C. for this reason
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 6/13/2018
Owner: y
GRIFFIN RANCH - L N�
981 MONTECITO D
CORONA, CA 9287�= pp cc
(S
Lr)t7 �
a CV
Cl— � CD
Contractor: LLJ
LENNAR HOMES -SHELLY JOIN v q
980 MONTECITO T '�
CORONA, CA 928 CD
tip
W
(951)817-3526
Llc. No.: AEC674
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
&f_ I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: Policy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date:/ffr' Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATIO OVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above -mentioned property for inspection purposes.
Date:S ^ Signature (Applicant or Agent). `x
Application Number:
BWFE2018-0109
Property Address:
81710 WAR ADMIRAL
APN:
767800033
Application Description:
GRIFFIN RANCH / BLOCK WALL 192 LF / LOT 108
Property Zoning:
Application Valuation:
$6,550.00
Applicant:
LENNAR HOMES-SHELLYJORDAN
980 MONTECITO DR STE
300
CORONA, CA 92879
Date
Owner:
GRIFFIN RANCH - LENNAR HOMES
981 MONTECITO DR STE 302
CORONA, CA 92879
Contractor:
LENNAR HOMES-SHELLYJORDAN
980 MONTECITO DR STE 300
CORONA, CA 92879
(951)817-3526
Uc. No.: AEC674
6/13/2018
Detail: 192 LF OF 6' GARDEN WALL [PROTO TYPE II SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED
COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A
SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. PER 2016 CALIFORNIA BUILDING CODES.
FINANCIAL
DESCRIPTION ACCOUNT
CITY
AMOUNT
WALL/FENCE - EA ADDITIONAL 50 LF
101-0000-42404
0
$31.20
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WALL/FENCE - FIRST 100 LF
101-0000-42404
0
$52.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WALL/FENCE - FIRST 100 LF PC
101-0000-42600
0
$65.02
Total Paid for BLOCK WALL: $148.23
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
CITY AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0 $10.00
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION
ACCOUNT
CITY AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0 $5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
LEGEND
PROPERTY LINE
— — — — — — — — PUBLIC UTILITY EASEMENT
— — — — — — RIGHT—OF—WAY (R/W)
GARDEN WALL
RETAINING / GARDEN WALL
TOP OF SLOPE
TOE OF SLOPE
LOT SCE L-3 [ I=
P2 Ce B3.«S
TW 480.00 TW 480.00 TW 479.33
1'F 47 .67 4 .8 TW 479.33 �O F 4 2.
471. TW 478.67
ry 4 . 77
14.1- 13.41'
LOT 108
PLAN 2A RT
FF 473.07 `�,.
PE 4724 :'_ [•ii"'� 7
LCF 53�
PS (CDI&o
TW 478.6
4 3
TW 479J3
TF 2 TW 478.67 TW 4.78.67
471.33 F 4 1, iW 478.67 h G 472.4
4�i' • . ,• N TF 470,67
? TVJ 478.00
- WAR 1ADMRAL DRIVE -
I
'!}
QR[M1 NATE ALL WALLS THAT ME VIEWABLE FROM THE MitFEf 4W.L BE Sd7ATCFi BROWN
�t
AND 20/30 TEXTURE WITH FAINT THAT MATCHES THE EXTERIOR OF THE HOME
IDM&A CONSMING, INC LEN NAR / CCU! RANCH
hmmm ■ QV& H . LAM yurv=m APRIL 2018
34200 H® Hlye Dan -Rm=m Mum . CA =M TRACT NO. 32879
1 °6°' M"" g"r C76I 3217889 LOT 108 - 81-710 War Admiral Drive LOT
772 AREA
LENNAR LA OUINT'A, RN3ME COUNTY, CALIFORNIA
980 MONTEWO DRTvE
CORONA, CA 92879 SCALE 1'=30'
(951) 817-38fi3
CITY OF LA QUI NTA
BUILDING & SAFETY DEPT.
APPROVED
F qR, (CONSTRUCTION
D►�Tl= f If- By MF
IL E `, 1 A l ■ 1601AL ITV ."
At. ti 121 D 4
I�
r�
SO.1
SO.2
SO.3
SOA
50.5
SI.1 6'-0- TO 6'-8' 6' CIAU FENCE W/ TRENCH FOOTING
$1.2 C-O' TO 6' 8' S" C1lU FENCE W/ DIP FOOTING
S1.3 6'-0' TO 6'-8" 6` CMU FENCE W/ PIER FOOTING
SIA 6'-O" TO 6'-8" 6' CMU FENCE W/ SPREAD FOOTING
52.F 7'-4' TO 8'-4' PRO70 11 6- COU FENCE WALL W/ CENT TRENCH FOOTING
$2.2 -� 14"-D' 10 12'-Q" PROTO II 8' CIAU FENCE WALL W/ CONI TTIENCIT FOOTING -
S3.1 1'-4" TO S-4' 6' CMU RFTAINING WALLS W/ CO%l 7RENC14 FTC & 6' PRO70 11 6' CMU FENCE ATOP
532 10'-a" TD S2'-0" PIlOTO II 8" CMU WALL W/ CONI'TREhCiI fTG k 3'-D" NAX RETAINING
S3.8 S-4" TO 4'-0` 8' CMU RETAINUIG WALLS W/ CONT TRENCH FTG k 6' PROTO 0 •S` CMU FENCE ATOPT
S3:4 Y-4" TO 4'-O" 8' CMU IiETAINUG WALLS W/ 110 TOE FIG k 6' PROTO II 6" CMU FENCE ATOP -
$3.5 S-4" TO 4'-D` 8' CMU RETAINING WALLS W/ ALL TOE FIG k 6' PROTO II 6' CMU FENCE ATOP
S4.1 _ 2'-0' TO fi -O" 8' CMU RETAINING WALLS W/ NO TOE fOOTING & NO FENCE ATOP
SC2 V-O' TO 6'-0' 8` CMU RETAINING WALLS W/ ALL TOE FOOTING At NO FENCE ATOP
S5.1 6'-0'•10 6'-0' 4' CMU FENCE W/ IREN0 FOOTING - - -
S5.2 6'-O' TO 6--a-4- CMU FENCC W/ DIP FOOTING _
_6'-0' TO 6'-8' 4" CMU FENCE W/ PIER FOOTING
55,1 ^8- CMU PItA�IER��''
S6;2 PROTO II 6" CMU LOW FENCE WALL 4�/ qLC SS' TIRO W E7STOP 1- - _
_ _f
CMU RETURN FENCE WAL4�. ,,RH FUO]I}[
S7.2 6'—W TO 6'—B" 6` CMU RETURN FENCE WALL V'$ 4ef}1N "E r 4
i F tiJ}; Co l'Is MUO'770 J
��- BY
�j
PLAN CHECK
03.07.17
REV #
DESCRIPT(ON
DATE
'SHEET INDEX
SHEET INGE%���
EASIS FOR DESIGN, CENERAL STRUCTURAL N07CS
GENERAL STRUCTURAL NOTES (CONI,), STANDARD ABBREUA1IONS
TYPICAL DETAILS
TYPICAL DETAILS -
PROJECT PROTO II STANDARD PLANS
WIND EXPOSURE C AT 110 MPli
LA OUIN*TEA.. CAA TITLE: SHEET INDEX
PROTO-IIT�I VI+Af-L SYSTEMS �DATE,02-00-17
RIMROCKEN13)NEE:NING 41500CASCADE$OOURT ATT&GARYOTTO OJNo:2TO
9430 W. CIiEYENNE AVE., STE Tf0 TE:.4ECUt CAp2001 PHN 611004.3793 SHEET: S�. J
F LASVEOAS WV69129 WYYW.FR070�.COV amodo®Prololl.CDrA Sol
PK-702-6150.5311 I FPA rff 5 1.04 son roeA7.410A51.a M.016 7i54 7 117secscni
T'nOTO.11 WALL SYSTEMS MAYQNLY GE INSTALLED By APPROVED AND CERTIFIED INSTALLERS
SEAL:
sslp
�9
94,1
C9 rM
rn
be No. C69616
* Exp. 6/:50/18
�OF CALOZ
03-07-1 7
Y R
I
.02iol
7. PROVIDE N HaRl2 t,l 16" U.C.
EACH WAY. AT 001 of F(*JI qG
3. EDGE OF rll,4;l[R i0011F;G
4. 4 VERT W IN EACH CoRfICR
LELL AS "s�i' Ow,v
5, 3 CtOSE17 TIES Al TOP AIID Al
S' 0 i. PAX. PROMS a" AIIN
SR01F1 COrLR ILL A;OUND
6- CPU PONCE %,AtL. PER
RPPLMLE YIAtL S£Cfi(ON
DETAIL, AS OCCURS
(i)
TYPICAL V' ruit
iiE1T10TES IcQW
7. PROMD1 VERTICAL Wn4s%
JOINTS IN FENCE VIALLS Pill GS1,
8, NON -.STRUCTURAL OECOiLATIVE
CAR/RNSCO PATTERN AS OCCURS
PER MCH. V;tsGffl NOT TO
Excuo 200 LDS
9. PROVIDE Vlfil DOWEL IN CELL
AOJACEN7 10 Piuwfm PER i'ERl
RCIRFORCINIG 91011IREIIE;4IS OF
APPUCAELE WALL SECTION DETAIL
IT. STORE VENEER 1-NO ATTACHMENT
BY OTI#ORS (TO 1'ST MAX)
ROTES
A. REFER TO GS14 MI) TI MCAT
DEWS FOR A0101110NAL
RCOVIRCmCnis AND 11[6TS
54Or414 Rill NOT NDIEO
B. WEI SET 1st COURSE INTO fIG-
4' Mara
C, PILASTER VAY RLffJla Up 10
PaUSI[RT!'00111OP 40/0 I1�t NG
REIAVED FACE IRkmICS AiTN
SIRUCTURAL RE001RE1+.ENT$ OF
APPMABLE RE NINC WILL
OETAR
so
mm PILASTER
OIr.!E1V5rJh
1
HEIGHT
a' cM11
TO[
Ixu �osIOIr
T -4" SO
8'-8"
0'-10•
-4" SO
T'-47 s0
la'-0•
1'-2-
2'-0"-SO
7'-�q•
2'-0" SO
6'-8"
2'-0" SO
_10'-0
Sa
-12'-0'
T'-0-
I BUILDING & SAFETY DC -.PT,
APPROVE SEAL
FOR CONSTRUGTIG
PROJECT; ROTO 11 STRN - a �y
WINE) EXPOSURE C AT 110 Mpli
[j PLAN CHECK oa oT•1T LA ❑UINT& CA x
rrva Besc+3lrrraN rn
PATE rrrLt' TYPICAL DETAILS m No. C69616 �
* EXf7. 6/30/18 .*
PH. , lre�l.u�:rnrrirrrn:,.�Pa,R.y�Ol ATPO.�7-1tI1IgT1LI WALLA�S�YOY"S�TFEMoAS.Cp1d
h:i4.:57p
�RCCF'Vry� CV1l
9030VV.HEY4 J 800 CASCAOCS COURT ATJ; GRRY OT7O PRJ
LA elCc[I vzral8_CALFSTE
707-A]B.S371 d¢
��.
PFiO70-II V.ALL SY57EMS MAY OM.Y BE 114STALLCA 13YF4,PTiOVCD AND GERr1FICb IhlSrei i rac Jl)
D3-07-17
�{r.1
DIP FIG DEI'fH AT TOP Of 2-1 SLOPE
ST11riCY, FACE Of CTG LAIN DIP FIG DIVIII
TO TOP OF SIOPf
1•..0' 10 X-0" 2.-�'
0'-3" 1D O'�II" T 1'
MAX WALL
MM DIP
liMill
I 0011Li
PI 140r11'S,PACING
G' CMU
SPACING
01
V-0"
10'-15- O.C.
V-0, O.C.
6' 8•
W11' O.C:
I'••tl� R.C.
CO A 114]_ CID
C, I „,IG
7 � —
Is
c�
tf
2 FAIN
`- 11
i]I�PAL
—A ----•------. . - --
KIYI 01FS
1,
POSI 1114SION ROD, REfER 10
SCHEDULE FOR SPACING
2.
1101WONTAI JOINI REINIORCING
PER GSN, PLACL IN FIRST mo
JLIINIS' MOVI NATE. WASHER
ANO 2'-0- O.C. WERFAF7lli
t mm lilt 701' 01 I'00TING M
irl:rCl IED
14 C.0141 RDNIF
4.
TOP Of LEAL NAIURAL GRADE
.OR C011PAVED S000RADr
5.
COldl, COICRETE SETTING PAD
6.
11OCKtN COKCHOC SETTING PAD
TO PROVIDE 3' my COvER
AROUND PT ROD AND NOT, AS
REV% WIIERE PT ROD DOES
NOl ALIGN Vf/ DIP FOOLING
7,
IINE Of OIP (-Tr- 8EY0140
8.
INLRCH IIAI 0E OVER
I-RCALVAILD AS SIIOIVN. FILL W/
COIAPACTFD FILL PER GSWOR
CONCRETE
9.
VERTICAL NEW W/ SID HOOK
AT DIP TOOIINGS Oft w LS
OMfi HICH. USE IN
-O' 14
IN CENTER OF DIP
113.
3' RORIFR COVER AROUND
COUPLER ►LYO OR POST
IENSIONED ROO AT FIRST COURSL
.Nm
A.
REIM TO GSN AND IYPIC&
CLIA LS FOR ADDITIONAL
REOUREMINTS AND REus
SNOVIN :HUT 1401 N01ED
0,
TYALI SHALL NOT BE USED AS A
FLOOD %VALL OR OTHTT W61
SURCHMGED, UNO
c,
PLACE F11;ST !LOCK INTO WEI
CONC f0 RECESS 1/2- LAIN.
3/4' MAY
D.
NO COLO JOMIIS ALL04YE0 IN
ON' FOOLING
E;
POST TENSION ROD -SPACING
DOES NOT NEED TO -LINE UP W/
DIP FOOIIIIG
5•-O' MIN i � •. l .. � Lr� L..�.! �V Ta lvnl�lir' �- r 7
`i
& qAF 7'1+ Vr-_-r
ED
'-0" & s'- 8 ' PROTO 11 6" =CMU 'FENCE WALL Wj DIP F&OTING-0) R"11311
NO scAL.r 1 ---
�
��-
0
a PROJECT: PROTO 11 STANQARD PLANS
WIND EXPOSURE C-AT I10 MPH
LA OUTAITA, CA
a m PLAN CHECk 03•07.17
t REV N DESCRIP1101DATE
T:TLI, TYPICAL DETAILS
3 PROTO-111r,1 WALL SYSTEMS vArn:n70a.17
'Y^
PRpJ l:If.-STD
RIMEi0C1t1:.1401IQ1: 1i11J1'S 4 18110 CASCADES COURT A11WGARYOTTO
n U030 VI. COWYENNE AVE, S7E 7.10 iG1uICCUL,1 CA9a591 I-Hq 1951I694.3793 SHCE11 � �'^
c LASVEGJ�5.MVG91'I9 YaW1N,PR0Ti02.0061 ptyalliofyT11ro1ot.cOtA L
P11 702-ma-5317 IIR f`A7Y.KfED 5,7Cr i7 I AL+717117 A? IVII+6].AD l: a4Q i+Si 7u li+t1,a67
PRCII WALL SYSTEIAS MAY OHLY DC 114STALLED 9Y APPROVED AND ( VRTIFif:T) IK-STALLERS'