Loading...
BSOL2018-001078-495 CALLE TAMPICO T4t�v D 4-u Quiaz VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 9/17/2018 Permit Type/Subtype: SOLAR/RESIDENTIAL LESS THAN 1OKW Owner: Application Number: BSOL2018-0010 TERRY LIVING TRUST Property Address: 78101 SAN TIMOTEO 78101 SAN TIMOTEO �- APN: 646160007 LA QUINTA, CA 92253 LL Application Description: TERRY RESIDENCE / ROOF MOUNT SOLAR Property Zoning: cr Application Valuation: $22,000.00 , L13 Applicant: Contractor; �' c, LUKE ROOFING INC LUKE ROOFING INC t-- C 26081 MERIT CIRCLE STE #125 26081 MERIT CIRCLE ST t--t O u LAGUNA HILLS, CA 92653 LAGUNA HILLS, CA 9265 LL L J cn U es (909)488-9726 Llc. No.: 672569 + S2 w --------------------••-------•--------------------------------------------------------------n LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C39, B License No.: 6725699 Date:! (L Contractor:._ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contra tor' State License Law for the following reason (Sec. 7031.5, Business and Profession C e: Any city or county that requires a permit to construct, alter, improve, demolish repair any structure, prior to its issuance, also requires the applicant for the per ' to file a signed statement that he or she is licensed pursuant to the provisions of Tle Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). I 11, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( _) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address; WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of thew rk f r which this permit is issued. and will maintain workers' compensation insurance, as requlred by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: STATE NATIONAL INSURANCE COMPANY INC Policy Number: CW714941001 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the LaboIFIN f rthwith comply with those provisions. Date: Applicant: - WARNING: FAILURE TO SECURE WORKERS' COMPENSATION CLAW L, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES U 0ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITIOCOMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 37B R CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit Issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. Date: �- Signature (Applicant or Agent): 'Date: 9/17/2018 Application Number: BSOL2018-0010 Property Address: 78101 SAN TIMOTEO APN: 646160007 Application Description: TERRY RESIDENCE / ROOF MOUNT SOLAR Property Zoning: Application Valuation: $22,000.00 Applicant: LUKE ROOFING INC 26081 MERIT CIRCLE STE #125 LAGUNA HILLS, CA 92653 Owner: TERRY LIVING TRUST 78101 SAN TIMOTEO LA QUINTA, CA 92253 Contractor: LUKE ROOFING INC 26081 MERIT CIRCLE STE #125 LAGUNA HILLS, CA 92653 (909)488-9726 Llc. No.: 672569 --------------------------------------------------------------------------------------------- Detail: 7.015 kW SOLAR ARRAY - (23) 305W QUANTUM PANELS+SOLAREDGE P320 OPTIMIZERS WITH SOLAREDGE SE 6000H-US DC INVERTER [415 SF). 2016 ELECTRICAL CODE DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 ::] 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT PV SYSTEM LESS THAN 10KW 101-0000-42403 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT PV SYSTEM LESS THAN 10KW PC 101-0000-42600 0 $26.01 Total Paid for ELECTRICAL: $52.02 DESCRIPTION ACCOUNT CITY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $98.83 Total Paid for PERMIT ISSUANCE: $98.83 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 Project Address: r P rrr APN #: Applicant Name: Z4 �f Address: City, ST, Zip: / { Telephone: Email: Property Owner's Name: Address: City, ST, Zip. Telephone: Email: PERMIT # L2,D 16 — 601 C PLAN LOCATION: Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech Valuation of Project $ !� _ �k)12 , New Commercial / Tenant Improvements: ► - 2, Total Building SF Construction Type: Occupancy: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal Req'd -Ree'd Plan Sets Structural Cales Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM 10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License HOMEOWNER: MIKETERRY PH: 949.466.ogoo APN: 646-160-007 ADDRESS: 78101 SAN TIMOTEO STREET LA QUINTA, CA 92253 PHOTOVOLTAIC SOLAR PROJECT INFORMATION: SYSTEM SIZE: 7.015 kW (DC) MODULES: (23) Q.CELLS Q.PEAK-G4.1305 PEAK POWER = 305 W MAX OPERATING CURRENT = 9.35 A MAX OPERATING VOLTAGE = 32.62 V OPEN CIRCUIT VOLTAGE = 40.05 V SHORT CIRCUIT CURRENT = 9.84 A MAX SERIES FUSE RATING = 20 A TEMP. COFFF. OF Voc=-0.28%/C DIMENSIONS = 65.7" X 39.4" X 1.31' WEIGHT = 41.5 LBS MODULE ADD -ON: (23) SOLAREDGE P320 DC POWER OPTIMIZERS MAX DC INPUT VOLTAGE = 48 V OPERATING VOLTAGE RANGE = 8 V- 48 V MAX DC INPUT CURRENT = 73.75 A MAX DC OUTPUT CURRENT =15 A DC OUTPUT VOLTAGE = 38o V MAX POWER PER STRING = 5700 W NEMA 6P ENCLOSURE DIMENSIONS = 5.0" X 6.0" X 1.1" WEIGHT =1.4 LB ARRAY: INSTALLED WEIGHT = 2.9 PSF ROOF COVERAGE = 415 SF, LESS THAN 50% OF TOTAL ROOF AREA MOUNTING HARDWARE: IRONRIDGEXR10 LIGHT RAIL IRONIll DGE L-FOOT ATTACHMENTS Y6" STAINLESS STEEL LAG BOLTS flu 72" OC OR LESS WITH A MINIMUM OF ZW' PENETRATION INTO ROOF RAFTERS r r VICINITY MAP SHEET INDEX: NTS SHEET 1 PROJECT INFO, VICINITY MAP, NOTES, SCOPE OF WORK SHEET 2 SITE/ROOF PLAN, ELEVATION DETAIL SHEETS ELECTRIC LINE DRAWING, CALCULATIONS SHEET 4 SIGNS ATTACHED MODULE, INVERTER, MOUNTING HARDWARE SPEC SHEETS, STRUCTURAL REPORT INVERTER/DC DISCONNECT: EXISTING ROOF INFO: 1 STORY, COMPOSITION SHINGLE (UNDER EIVE 2 X 6 RAFTERS @ 24" OC f4m, 5EP 06 2018 CFfY OF LA QUINTA NOTICE: COMMUNFFY DEVELOPMENT ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. (1) SOLAREDGE SE6000H-US [S11] MAX DC INPUT VOLTAGE = 48o V NOMINAL DC INPUT VOLTAGE = 38o V MAX DC INPUT CURRENT =16.5 A DC DISCONNECT MAX INPUT CURRENT = 45.o A NUMBER OF DC INPUTS = 2 RATED AC POWER = 60oo W AC VOLTAGE = 240 V MAX AC OUTPUT CURRENT = 25.o A NEMA3R ENCLOSURE WEIGHT o25 LBS 7"X14' OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE q COMPLIANCE DATE r I1 "PSY SCOPE OF WORK: LUKE ROOFING INSTALL (23) Q.CELLS Q.PEAK-G4.1 305 SOLAR ELECTRIC MODULES AND INCORPORATED (23) SOLAREDGE P320 DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY 26o81 MERIT CIRCLE #125 COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, LAGUNA HILLS, CA 92653 JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL PH: 714.633.8798 (1) SOLAREDGE SE6000H-US [S11] INVERTER WITH INTEGRATED DC DISCONNECT, (1) SQUARE D DU222RB AC DISCONNECT, AND INSTALL OCPD IN SUB PANEL. GENERAL NOTES: 1. ALL CONSTRUCTION SHALL COMPLY WITH THE 2016 CALIFORNIA BUILDING RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, ENERGY, AND GREEN BUILDING CODES AND THE LA QUI NTA MUNICIPAL CODE. 2. THE SYSTEM WILL NOT BE TURNED -ON UNTIL THE SERVING UTILITY COMPANY HAS BEEN NOTIFIED. 3. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT LESS THAN 4 PSF. 4. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 40 LBS. 5. ALL PV EQUIPMENT IS LISTED BYA RECOGNIZED TESTING LAB. INVERTERS ARE UL 1741 COMPLIANT. 6. PHOTOVOLTAIC EQUIPMENTAND SYSTEMS AND ALLASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONS PER CEC 690.4(E). 7. THE BACKFED BREAKER WILL BE LOCATED AT THE OPPOSITE END OF THE BUS FROM THE MAIN BREAKER. 8. CONDUCTORS ARE 90' C RATED COPPER WIRE. 9. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIEDAND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET PER CEC 690.4(B). 1o. ANY CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT RESISTANT. 11. IF DC CONDUCTORS ARE RUN INSIDE THE BUILDING, THEY WILL BE CONTAINED IN A METAL RACEWAY. 12. ANY CONDUCTORS BETWEEN SEPARATE ARRAYS ON THE ROOF WILL BE PROTECTED IN CONDUIT. 13. THE EQUIPMENT GROUNDING CONDUCTOR ON THE ROOF WILL BE PROTECTED FROM PHYSICAL DAMAGE. IT WILL BE TUCKED NEATLY UNDER THE MODULES AND RAILS AND SECURED IN PLACE. 14. THE MODULES WILL BE ATTACHED TO THE EQUIPMENT GROUNDING CONDUCTOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 15. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES ARE RAIN -TIGHT AND APPROVED FOR USE IN WET LOCATIONS. 16, CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. 17. SOLAR MODULES WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. 18. IFTHE EXISTING MAIN SERVICE PANEL DOES NOT HAVEAVERIFIABLE GROUNDING ELECTRODE SYSTEM, A GROUNDING ELECTRODE SYSTEM WILL BE INSTALLED PER CEC 250.50. THE ELECTRICAL SERVICE WILL BE BONDED (� TO THE WATER AND GAS PIPING PER SECTION 250.104 OF THE CEC. 19. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CAL -OSHA REGULATIONS. 1 DESCRIPTION: 00 BEING LOT 7 OF LA QUINTA GOLF ESTATES 2 RECORDED AS PAGE 26 IN V MAP BOOK 38 OF RIVERSIDE COUNTY OFFICIAL RECORDS. 41, GARY DEAN LUKE B - 6 22569 nerr. Q -1.0 PLANS PREPARED BY: JENNIFER KEMME PH: 909.754.8300 f!� SHEET 1 OF a �, HOMEOWNER: MIKE TERRY PH: 949.466.o9oo APN: 646-160-007 ADDRESS: 78101 SAN TIMOTEO STREET LA QUINTA, CA 92253 IRONRIDGEXR10 LIGHT RAIL MOUNTING SYSTEM WITH IRONRIDGE L-FOOT ROOF ATTACHMENTS (USE Yi6" STAINLESS STEEL LAG BOLTS [7a 72" OC OR LESS WITH A MINIMUM EMBEDMENT OF 2Yz" INTO ROOF RAFTERS), WATERPROOF ALL CONNECTION LOCATIONS PER MANUFACTURER'S INSTRUCTIONS EXISTING 1-STORY ROOF: COMPOSITION SHINGLE (UNDER ARRAY), FELT & 2" SHEATHING OVER RAFTERS MODULES: 65 7" X 39.4" 41.5 LBS EACH PROPERTY LINE 3" MIN. 8" MAX. T / I EXISTING 2 X 6 RAFTERS @a 24" OC ELEVATION DETAIL NTS 8'-711 NOTICE: ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. / SCOPE OF WORK: LAKE ROOFING INSTALL (23) Q.CELLS Q.PEAK-G4.1305 SOLAR ELECTRIC MODULES AND INCORPORATED (23) SOLAREDGE P32o DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY 26o81 MERIT CIRCLE #125 COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, LAGUNA HILLS, CA 92653 JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL PH: 714.633.8798 (1) SOLAREDGE SE6000H-US [S11] INVERTER WITH INTEGRATED DC DISCONNECT, (1) SQUARE D DU222RB AC DISCONNECT, AND INSTALL OCPD IN SUB PANEL. SAN TIMOTEO STREET 18'-1" 06 (E) 200 AMP SUB PANEL (INSIDE GARAGE) I (E) 400 AMP MAIN SERVICE PANEL (N) AC DISCONNECT (N) INVERTER/ DC DISCONNECT ARRAY#1: (23) MODULES TILT =18°,AZ=11g° PROPERTY LINE SCALE:1/16"=1' 16 32 43 SITE/ROOF PLAN NOTE: DIMENSIONS AND FEATURES SHOWN ARE CLOSE TO SCALE BUT WERE TAKEN FROM AFIELD SURVEY AND APPROXIMATIONS MADE USING GOOGLE EARTH. PLANS PREPARED BY: JENNIFER KEMME PH: 909.754.8300 GARY DEAN LUKE B - 672569 DATE: 8/29/18 SHEET 2OF4 HOMEOWNER: MIKETERRY PH: 949.466.ogoo APN: 646-160-007 ADDRESS: 781o1 SAN TIMOTEO STREET LA QU I NTA, CA 92253 (11) 600 VDC SOURCE CIRCUIT#1: SOLAREDGE P320 j 11 MODULES, 600 VDC OPTIMIZERS J I Q.CELLS UI I Q.PEAK-G4.1305 n 1-I Q.CELLS + I Q.PEAK-G4.1305 �l Q.CELLS V T Q.PEAK-G4.13o5 I SOURCE CIRCUIT#2: 12 MODULES, 600 VDC Q.CELLS Q Q. P EAK-G4.1 305 r1 Q.CELLS Q Q.PEAK-G4.1305 n I�Q.CELLS Q.PEAK-G4.1305 (4)10 AWG PV IN AIR NEMA 3R, 600 VDC JUNCTION BOX I + I I I (12) 600 VDC SOLAREDGE P320 OPTIMIZERS ----------------- [USE IRONRIDGE INTEGRATED GROUNDING TO GROUND ALL MODULES, OPTIMIZERS, JUNCTION BOXES AND ANY OTHER METAL PARTS AND #6 AWG SOLID COPPER WHERE NECESSARY (4)10 AWG THWN-2 & (1) 8 AWG GROUND IN X4" EMT CONDUIT CONDUIT MUST BE SUPPORTED A MINIMUM OFY2" ABOVE THE ROOF SURFACE. NOTE: PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS SHALL NOT BE CONTAINED IN THE SAME RACEWAY, CABLE TRAY, CABLE, OUTLET BOX, JUNCTION BOX, OR SIMILAR FITTING AS CONDUCTORS, FEEDERS, BRANCH CIRCUITS OF OTHER NON-PV SYSTEMS, OR INVERTER OUTPUT CIRCUITS UNLESS THE CONDUCTORS OF THE DIFFERENT SYSTEMS ARE SEPARATED BY A PARTITION. PV SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED AS REQUIRED BY 690.31(B)(1) THROUGH (4). THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. (CEC §690.313(B)) (3) 8 AWG THWN-2 & (1) 8 AWG GROUND IN Y4" EMT CONDUIT SOLAREDGE SE6000H-US [S11] 240 VAC, 10 TRANSFORMERLESS INVERTEI SOLAREDGE INTEGRATED DC DISCONNECT & RAPID SHUTDOWN DEVICE SQUARE D 6o A, 240 VAC, 10 AC DISCONNECT LOCKABLE, VISIBLE KNIFE-BLADETYPE (DU222RB) ELECTRICAL LINE DIAGRAM SUB PANEL zoo A BUS RATED 240 VAC, 10 4oA 0 (3) 8 AWG THWN-2 &� L- (1) 8 AWG GROUND IN Y4" EMT CONDUIT CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR THIS SYSTEM IS RAPID SHUTDOWN READY PER CEC 690.12. CODE COMPLIANCE SYSTEM CALCULATIONS: MODULE POWER = 305 W NUMBER OF MODULES IN LONGEST STRING =12 (12) 305 W = 366o W OPTIMIZER MAX POWER PER STRING = 5700 W 366o W < 5700 W, OK OPERATING CURRENT = POWER RATING/OPERATING VOLTAGE = 366o W1380 V = 9.63 A OPTIMIZER TO INVERTER TARGET VOLTAGE/OPERATING VOLTAGE = 38o V MAX SYSTEM VOLTAGE (Voc) CONTROLLED BY INVERTER = 480 V SHORT-CIRCUIT CURRENT (Isc) CONTROLLED BY OPTIMIZER =15.00 A INVERTER MAX OUTPUT CURRENT = 25.00 A 25.00 A (1.25) = 31.25 A [Ic], USE 4o A BREAKER SUB PANEL BUS RATING = 200 A SUB PANEL MAIN OCPD = 200 A zoo A + 4o A SOLAR OCPD = 240 A zoo A BUS (1.2) = 24o A 24oA=24oA,OK DATEBY_..__ WIRE CALCULATIONS: EXISTING SPLIT MAIN SERVICE PANEL: 400 A, 240 VAC, 10 M 2ooA 0 rH MAIN SERVICE INFO: 40o A,120/240 VAC, 10, 3-WIRE PANEL DOES NOT HAVE A CENTER MAIN BREAKER EXISTING BUILDING GROUNDING ELECTRODE SYSTEM FROM OPTIMIZERS TO INVERTER/DC DISCONNECT: AMBIENT TEMPERATURE = 47°C TEMPERATURE ADDER FOR CONDUIT OFFSET FROM ROOF BY34" MINIMUM = 220C ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR go°C INSULATED CONDUCTOR AT 470C + 220C = 690C = o.58 Isc =15.00 A 15.00 A/o.58 = 25.86 A NUMBER OF CURRENT CARRYING CON DUCTORS I N CON DUIT = 4 ADJUSTMENT FACTOR PER TABLE 310.15(B)(3)(a) FOR CONDUIT FILL (4-6 CONDUCTORS IN CONDUIT) = o.8o 25.86 A/o.8o = 32.33 A SELECT WIRE SIZE WITH AMPACITY GREATER THAN 32.33 A, USE 10 AWG THWN-2 COPPER WIRE WITH AN AMPACITY OF 4o A SELECT CONDUIT FOR (4)10 AWG THWN-2 & (1) 8 AWG GROUND = Y4" EMT CONDUIT FROM THE INVERTER TO THE SUB PANEL: ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(2) FOR go°C INSULATED CONDUCTOR AT 470C = o.82 Ic = 31.25 A 31.25 A/o.82 = 38.11 A SELECT WIRE SIZE WITH AMPACITY GREATER THAN 38.11 A, USE 8 AWG THWN-2 COPPER WIRE WITH AN AMPACITY OF 55 A SELECT CONDUIT FOR (3) 8 AWG THWN-2 & (1) 8 AWG GROUND = Y4" EMT CONDUIT SCOPE OF WORK: LUKE ROOFING INSTALL (23) Q.CELLS Q.PEAK-G4.1 305 SOLAR ELECTRIC MODULES AND NOTICE: INCORPORATED (23) SOLAREDGE P32o DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY ANY CHANGES TO OR USES OF THESE 26o81 MERIT CIRCLE #125 COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, DOCUMENTS/DRAWINGS WITHOUT THE LAGUNA HILLS, CA 92653 JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL WRITTEN CONSENT OF ]ENNIFER KEMME OR PH: 714.633.8798 (1) SOLAREDGE SE6000H-US [S11] INVERTER WITH INTEGRATED DC DISCONNECT, SCOTT HARRIS ARE STRICTLY PROHIBITED. (1) SQUARE D DU222RB AC DISCONNECT, AND INSTALL OCPD IN SUB PANEL. GARY DEAN LUKE B - 672569 DATE: 8/29/18 PLANS PREPARED BY: JENNIFER KEMME PH: 909.754.8300 SHEET 3 OF 4 »n-)-,P\/ HOMEOWNER: MIKETERRY PH: 949.466.0900 APN: 646-160-007 ADDRESS: 781o1 SAN TIMOTEO STREET LA QUINTA, CA 92253 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN. N SOLAR ARRAY r (ON ROOF) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN INVERTER & DC DISCONNECT PV SYSTEM DISCONNECT FOR UTILITY OPERATION SERVICE POINT & UTILITY METERING ADDRESS: 78101 SAN TIMOTEO STREET, LA QUINTA, CA 92253 10 BL INS IALLED ON THE OUTSIDE COVER OF THE MAIN SERVICE DISCONNECT: NOTICE: ANY CHANGES TO OR USES OF THESE DOCLIMENTS/DRAWINGS WITHOUT THE WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. SYSTEM SIGNAGE ALL SIGNAGE SHALL BE REFLECTIVE, UV RESISTANT PLASTIC, RED IN COLOR WITH WHITE LETTERING, AND ATTACHED WITH WEATHERPROOF ADHESIVE OR OTHER APPROVED METHOD. ALL LETTERS SHALL BE A MINIMUM OFY" HEIGHTAND ALL CAPITALIZED. ALL CONDUIT, JUNCTION BOXES AND OTHER ENCLOSURES SHALL BE MARKED AT 1o' MAX INTERVALS AND AT ALL BENDS, TERMINATIONS, SPLICES OR CONNECTIONS WITH "WARNING: PHOTOVOLTAIC POWER SOURCE". 690.5(C) - INVERTER 705.12(D)(7) - PANELBOARD CEC 690.31(E)(3) AND CFC 605.11.1.2 - DC CIRCUITS, JBOXES, ETC. ITY OF LA QUIN1 BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE BY 690.17/690.54 - AC DISCONNECT 690.17/690.53 - DC DISCONNECT 690.56(B)/705.10 - SERVICE 690.35(F) - UNGROUNDED DC CIRCUITS SCOPE OF WORK: LUKE ROOFING INSTALL (23) Q.CELLS Q.PEAK-G4.1305 SOLAR ELECTRIC MODULES AND INCORPORATED (23) SOLAREDGE P32o DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY 26o81 MERIT CIRCLE #125 COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, LAGUNA HILLS, CA 92653 JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL PH: 714.633.8798 (1) SOLAREDGE SE6000H-US [S11] INVERTER WITH INTEGRATED DC DISCONNECT, (1) SQUARE D DU222RB AC DISCONNECT, AND INSTALL OCPD IN SUB PANEL. GARY DEAN LUKE B - 672569 DATE: 8/29/18 PLANS PREPARED BY: JENNIFER KEMME PH: 909.754.8300 SHEET 4OF4