BSOL2018-001078-495 CALLE TAMPICO T4t�v D 4-u Quiaz VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 9/17/2018
Permit Type/Subtype:
SOLAR/RESIDENTIAL LESS THAN 1OKW
Owner:
Application Number:
BSOL2018-0010
TERRY LIVING TRUST
Property Address:
78101 SAN TIMOTEO
78101 SAN TIMOTEO
�-
APN:
646160007
LA QUINTA, CA 92253
LL
Application Description:
TERRY RESIDENCE / ROOF MOUNT SOLAR
Property Zoning:
cr
Application Valuation:
$22,000.00
,
L13
Applicant:
Contractor;
�'
c,
LUKE ROOFING INC
LUKE ROOFING INC
t--
C
26081 MERIT CIRCLE STE #125
26081 MERIT CIRCLE ST
t--t
O u
LAGUNA HILLS, CA 92653
LAGUNA HILLS, CA 9265
LL
L J
cn
U es
(909)488-9726
Llc. No.: 672569
+
S2
w
--------------------••-------•--------------------------------------------------------------n
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 70001 of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C39, B License No.: 6725699
Date:! (L Contractor:._
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contra tor' State
License Law for the following reason (Sec. 7031.5, Business and Profession C e: Any
city or county that requires a permit to construct, alter, improve, demolish repair
any structure, prior to its issuance, also requires the applicant for the per ' to file a
signed statement that he or she is licensed pursuant to the provisions of Tle
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(1 I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
I 11, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
( _) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address;
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of thew rk f r which this permit is issued.
and will maintain workers' compensation insurance, as requlred by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: STATE NATIONAL INSURANCE COMPANY INC Policy Number:
CW714941001
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the LaboIFIN
f rthwith
comply with those provisions.
Date: Applicant:
-
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION CLAW L,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES U 0ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITIOCOMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 37B R CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
Issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above -mentioned property for inspection purposes.
Date: �- Signature (Applicant or Agent):
'Date: 9/17/2018
Application Number:
BSOL2018-0010
Property Address:
78101 SAN TIMOTEO
APN:
646160007
Application Description:
TERRY RESIDENCE / ROOF MOUNT SOLAR
Property Zoning:
Application Valuation:
$22,000.00
Applicant:
LUKE ROOFING INC
26081 MERIT CIRCLE STE #125
LAGUNA HILLS, CA 92653
Owner:
TERRY LIVING TRUST
78101 SAN TIMOTEO
LA QUINTA, CA 92253
Contractor:
LUKE ROOFING INC
26081 MERIT CIRCLE STE #125
LAGUNA HILLS, CA 92653
(909)488-9726
Llc. No.: 672569
---------------------------------------------------------------------------------------------
Detail: 7.015 kW SOLAR ARRAY - (23) 305W QUANTUM PANELS+SOLAREDGE P320 OPTIMIZERS WITH SOLAREDGE SE 6000H-US DC INVERTER [415 SF). 2016
ELECTRICAL CODE
DESCRIPTION
ACCOUNT CITY
AMOUNT
BSAS SB1473 FEE
101-0000-20306 ::] 0
$1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA:
$1.00
DESCRIPTION
ACCOUNT QTY
AMOUNT
PV SYSTEM LESS THAN 10KW
101-0000-42403 0
$26.01
DESCRIPTION
ACCOUNT CITY
AMOUNT
PV SYSTEM LESS THAN 10KW PC
101-0000-42600 0
$26.01
Total Paid for ELECTRICAL:
$52.02
DESCRIPTION
ACCOUNT CITY
AMOUNT
PERMIT ISSUANCE
101-0000-42404 0
$98.83
Total Paid for PERMIT ISSUANCE:
$98.83
DESCRIPTION
ACCOUNT QTY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416 0
$10.00
Total Paid for RECORDS MANAGEMENT FEE:
$10.00
DESCRIPTION
ACCOUNT QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611 0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE:
$5.00
Project Address: r P rrr
APN #:
Applicant Name: Z4 �f
Address:
City, ST, Zip: / {
Telephone:
Email:
Property Owner's Name:
Address:
City, ST, Zip.
Telephone:
Email:
PERMIT # L2,D 16 — 601 C
PLAN LOCATION:
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
Valuation of Project $
!� _ �k)12 , New Commercial / Tenant Improvements:
► - 2, Total Building SF
Construction Type: Occupancy:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
OFFICE USE ONLY
#
Submittal
Req'd
-Ree'd
Plan Sets
Structural Cales
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM 10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
HOMEOWNER: MIKETERRY
PH: 949.466.ogoo
APN: 646-160-007
ADDRESS: 78101 SAN TIMOTEO STREET
LA QUINTA, CA 92253
PHOTOVOLTAIC SOLAR PROJECT INFORMATION:
SYSTEM SIZE: 7.015 kW (DC)
MODULES: (23) Q.CELLS Q.PEAK-G4.1305
PEAK POWER = 305 W
MAX OPERATING CURRENT = 9.35 A
MAX OPERATING VOLTAGE = 32.62 V
OPEN CIRCUIT VOLTAGE = 40.05 V
SHORT CIRCUIT CURRENT = 9.84 A
MAX SERIES FUSE RATING = 20 A
TEMP. COFFF. OF Voc=-0.28%/C
DIMENSIONS = 65.7" X 39.4" X 1.31'
WEIGHT = 41.5 LBS
MODULE ADD -ON: (23) SOLAREDGE P320
DC POWER OPTIMIZERS
MAX DC INPUT VOLTAGE = 48 V
OPERATING VOLTAGE RANGE = 8 V- 48 V
MAX DC INPUT CURRENT = 73.75 A
MAX DC OUTPUT CURRENT =15 A
DC OUTPUT VOLTAGE = 38o V
MAX POWER PER STRING = 5700 W
NEMA 6P ENCLOSURE
DIMENSIONS = 5.0" X 6.0" X 1.1"
WEIGHT =1.4 LB
ARRAY:
INSTALLED WEIGHT = 2.9 PSF
ROOF COVERAGE = 415 SF,
LESS THAN 50% OF TOTAL ROOF AREA
MOUNTING HARDWARE: IRONRIDGEXR10 LIGHT RAIL
IRONIll DGE L-FOOT ATTACHMENTS
Y6" STAINLESS STEEL LAG BOLTS flu
72" OC OR LESS WITH A MINIMUM OF
ZW' PENETRATION INTO ROOF RAFTERS
r
r
VICINITY MAP
SHEET INDEX: NTS
SHEET 1 PROJECT INFO, VICINITY MAP, NOTES, SCOPE OF WORK
SHEET 2 SITE/ROOF PLAN, ELEVATION DETAIL
SHEETS ELECTRIC LINE DRAWING, CALCULATIONS
SHEET 4 SIGNS
ATTACHED MODULE, INVERTER, MOUNTING HARDWARE SPEC SHEETS,
STRUCTURAL REPORT
INVERTER/DC DISCONNECT:
EXISTING ROOF INFO: 1 STORY, COMPOSITION SHINGLE (UNDER EIVE 2 X 6 RAFTERS @ 24" OC f4m,
5EP 06 2018
CFfY OF LA QUINTA
NOTICE: COMMUNFFY DEVELOPMENT
ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE
WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED.
(1) SOLAREDGE SE6000H-US [S11]
MAX DC INPUT VOLTAGE = 48o V
NOMINAL DC INPUT VOLTAGE = 38o V
MAX DC INPUT CURRENT =16.5 A
DC DISCONNECT MAX INPUT CURRENT = 45.o A
NUMBER OF DC INPUTS = 2
RATED AC POWER = 60oo W
AC VOLTAGE = 240 V
MAX AC OUTPUT CURRENT = 25.o A
NEMA3R ENCLOSURE
WEIGHT o25 LBS 7"X14' OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
q COMPLIANCE
DATE r I1 "PSY
SCOPE OF WORK:
LUKE ROOFING INSTALL (23) Q.CELLS Q.PEAK-G4.1 305 SOLAR ELECTRIC MODULES AND
INCORPORATED (23) SOLAREDGE P320 DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY
26o81 MERIT CIRCLE #125 COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE,
LAGUNA HILLS, CA 92653 JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL
PH: 714.633.8798 (1) SOLAREDGE SE6000H-US [S11] INVERTER WITH INTEGRATED DC DISCONNECT,
(1) SQUARE D DU222RB AC DISCONNECT, AND INSTALL OCPD IN SUB PANEL.
GENERAL NOTES:
1. ALL CONSTRUCTION SHALL COMPLY WITH THE 2016 CALIFORNIA BUILDING
RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, ENERGY, AND GREEN
BUILDING CODES AND THE LA QUI NTA MUNICIPAL CODE.
2. THE SYSTEM WILL NOT BE TURNED -ON UNTIL THE SERVING UTILITY
COMPANY HAS BEEN NOTIFIED.
3. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT LESS THAN 4
PSF.
4. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 40
LBS.
5. ALL PV EQUIPMENT IS LISTED BYA RECOGNIZED TESTING LAB. INVERTERS
ARE UL 1741 COMPLIANT.
6. PHOTOVOLTAIC EQUIPMENTAND SYSTEMS AND ALLASSOCIATED WIRING
AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED
PERSONS PER CEC 690.4(E).
7. THE BACKFED BREAKER WILL BE LOCATED AT THE OPPOSITE END OF THE
BUS FROM THE MAIN BREAKER.
8. CONDUCTORS ARE 90' C RATED COPPER WIRE.
9. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIEDAND
GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY
SEPARATE COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED
MEANS. THE MEANS OF GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS
AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET PER
CEC 690.4(B).
1o. ANY CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT
RESISTANT.
11. IF DC CONDUCTORS ARE RUN INSIDE THE BUILDING, THEY WILL BE
CONTAINED IN A METAL RACEWAY.
12. ANY CONDUCTORS BETWEEN SEPARATE ARRAYS ON THE ROOF WILL BE
PROTECTED IN CONDUIT.
13. THE EQUIPMENT GROUNDING CONDUCTOR ON THE ROOF WILL BE
PROTECTED FROM PHYSICAL DAMAGE. IT WILL BE TUCKED NEATLY UNDER
THE MODULES AND RAILS AND SECURED IN PLACE.
14. THE MODULES WILL BE ATTACHED TO THE EQUIPMENT GROUNDING
CONDUCTOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
15. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES ARE RAIN -TIGHT AND
APPROVED FOR USE IN WET LOCATIONS.
16, CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT WILL BE MAINTAINED
IN ACCORDANCE WITH CEC 110.26.
17. SOLAR MODULES WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR
BUILDING ROOF VENTS.
18. IFTHE EXISTING MAIN SERVICE PANEL DOES NOT HAVEAVERIFIABLE
GROUNDING ELECTRODE SYSTEM, A GROUNDING ELECTRODE SYSTEM WILL
BE INSTALLED PER CEC 250.50. THE ELECTRICAL SERVICE WILL BE BONDED (�
TO THE WATER AND GAS PIPING PER SECTION 250.104 OF THE CEC.
19. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH
CAL -OSHA REGULATIONS.
1 DESCRIPTION: 00
BEING LOT 7 OF LA QUINTA GOLF ESTATES 2 RECORDED AS PAGE 26 IN V
MAP BOOK 38 OF RIVERSIDE COUNTY OFFICIAL RECORDS.
41,
GARY DEAN LUKE B - 6 22569
nerr. Q -1.0
PLANS PREPARED BY:
JENNIFER KEMME
PH: 909.754.8300
f!�
SHEET
1 OF a �,
HOMEOWNER: MIKE TERRY
PH: 949.466.o9oo
APN: 646-160-007
ADDRESS: 78101 SAN TIMOTEO STREET
LA QUINTA, CA 92253
IRONRIDGEXR10 LIGHT RAIL
MOUNTING SYSTEM WITH
IRONRIDGE L-FOOT ROOF
ATTACHMENTS (USE Yi6"
STAINLESS STEEL LAG BOLTS [7a
72" OC OR LESS WITH A MINIMUM
EMBEDMENT OF 2Yz" INTO ROOF
RAFTERS), WATERPROOF ALL
CONNECTION LOCATIONS PER
MANUFACTURER'S INSTRUCTIONS
EXISTING 1-STORY ROOF:
COMPOSITION SHINGLE
(UNDER ARRAY),
FELT & 2" SHEATHING
OVER RAFTERS
MODULES:
65 7" X 39.4"
41.5 LBS EACH
PROPERTY LINE
3" MIN.
8" MAX.
T
/
I
EXISTING 2 X 6
RAFTERS @a 24" OC
ELEVATION DETAIL
NTS
8'-711
NOTICE:
ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE
WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. /
SCOPE OF WORK:
LAKE ROOFING
INSTALL (23) Q.CELLS Q.PEAK-G4.1305 SOLAR ELECTRIC MODULES AND
INCORPORATED
(23) SOLAREDGE P32o DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY
26o81 MERIT CIRCLE #125
COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE,
LAGUNA HILLS, CA 92653
JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL
PH: 714.633.8798
(1) SOLAREDGE SE6000H-US [S11] INVERTER WITH INTEGRATED DC DISCONNECT,
(1) SQUARE D DU222RB AC DISCONNECT, AND INSTALL OCPD IN SUB PANEL.
SAN TIMOTEO STREET
18'-1"
06
(E) 200 AMP SUB PANEL
(INSIDE GARAGE)
I
(E) 400 AMP MAIN
SERVICE PANEL
(N) AC DISCONNECT
(N) INVERTER/
DC DISCONNECT
ARRAY#1: (23) MODULES
TILT =18°,AZ=11g°
PROPERTY LINE
SCALE:1/16"=1'
16 32 43
SITE/ROOF PLAN
NOTE:
DIMENSIONS AND FEATURES SHOWN ARE CLOSE TO
SCALE BUT WERE TAKEN FROM AFIELD SURVEY AND
APPROXIMATIONS MADE USING GOOGLE EARTH.
PLANS PREPARED BY:
JENNIFER KEMME
PH: 909.754.8300
GARY DEAN LUKE B - 672569
DATE: 8/29/18
SHEET
2OF4
HOMEOWNER: MIKETERRY
PH: 949.466.ogoo
APN: 646-160-007
ADDRESS: 781o1 SAN TIMOTEO STREET
LA QU I NTA, CA 92253
(11) 600 VDC
SOURCE CIRCUIT#1: SOLAREDGE P320 j
11 MODULES, 600 VDC OPTIMIZERS J
I Q.CELLS UI
I Q.PEAK-G4.1305 n
1-I Q.CELLS + I
Q.PEAK-G4.1305 �l
Q.CELLS V
T Q.PEAK-G4.13o5
I
SOURCE CIRCUIT#2:
12 MODULES, 600 VDC
Q.CELLS Q
Q. P EAK-G4.1 305 r1
Q.CELLS Q
Q.PEAK-G4.1305 n
I�Q.CELLS
Q.PEAK-G4.1305
(4)10 AWG PV IN AIR
NEMA 3R, 600 VDC
JUNCTION BOX
I
+ I
I
I
(12) 600 VDC
SOLAREDGE P320
OPTIMIZERS
-----------------
[USE IRONRIDGE INTEGRATED GROUNDING TO
GROUND ALL MODULES, OPTIMIZERS, JUNCTION
BOXES AND ANY OTHER METAL PARTS AND
#6 AWG SOLID COPPER WHERE NECESSARY
(4)10 AWG THWN-2 &
(1) 8 AWG GROUND
IN X4" EMT CONDUIT
CONDUIT MUST BE SUPPORTED A MINIMUM
OFY2" ABOVE THE ROOF SURFACE.
NOTE:
PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS SHALL NOT BE
CONTAINED IN THE SAME RACEWAY, CABLE TRAY, CABLE, OUTLET
BOX, JUNCTION BOX, OR SIMILAR FITTING AS CONDUCTORS,
FEEDERS, BRANCH CIRCUITS OF OTHER NON-PV SYSTEMS, OR
INVERTER OUTPUT CIRCUITS UNLESS THE CONDUCTORS OF THE
DIFFERENT SYSTEMS ARE SEPARATED BY A PARTITION. PV SYSTEM
CONDUCTORS SHALL BE IDENTIFIED AND GROUPED AS REQUIRED
BY 690.31(B)(1) THROUGH (4). THE MEANS OF IDENTIFICATION
SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING
TAPE, TAGGING, OR OTHER APPROVED MEANS. (CEC §690.313(B))
(3) 8 AWG THWN-2 &
(1) 8 AWG GROUND
IN Y4" EMT CONDUIT
SOLAREDGE SE6000H-US [S11]
240 VAC, 10
TRANSFORMERLESS INVERTEI
SOLAREDGE INTEGRATED
DC DISCONNECT & RAPID
SHUTDOWN DEVICE
SQUARE D 6o A,
240 VAC, 10
AC DISCONNECT
LOCKABLE, VISIBLE
KNIFE-BLADETYPE
(DU222RB)
ELECTRICAL LINE DIAGRAM
SUB PANEL
zoo A BUS RATED
240 VAC, 10
4oA
0
(3) 8 AWG THWN-2 &� L-
(1) 8 AWG GROUND
IN Y4" EMT CONDUIT
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
THIS SYSTEM IS RAPID SHUTDOWN READY PER CEC 690.12. CODE
COMPLIANCE
SYSTEM CALCULATIONS:
MODULE POWER = 305 W
NUMBER OF MODULES IN LONGEST STRING =12
(12) 305 W = 366o W
OPTIMIZER MAX POWER PER STRING = 5700 W
366o W < 5700 W, OK
OPERATING CURRENT = POWER RATING/OPERATING VOLTAGE = 366o W1380 V = 9.63 A
OPTIMIZER TO INVERTER TARGET VOLTAGE/OPERATING VOLTAGE = 38o V
MAX SYSTEM VOLTAGE (Voc) CONTROLLED BY INVERTER = 480 V
SHORT-CIRCUIT CURRENT (Isc) CONTROLLED BY OPTIMIZER =15.00 A
INVERTER MAX OUTPUT CURRENT = 25.00 A
25.00 A (1.25) = 31.25 A [Ic], USE 4o A BREAKER
SUB PANEL BUS RATING = 200 A
SUB PANEL MAIN OCPD = 200 A
zoo A + 4o A SOLAR OCPD = 240 A
zoo A BUS (1.2) = 24o A
24oA=24oA,OK
DATEBY_..__
WIRE CALCULATIONS:
EXISTING SPLIT
MAIN SERVICE PANEL:
400 A, 240 VAC, 10
M
2ooA
0
rH
MAIN SERVICE INFO:
40o A,120/240 VAC,
10, 3-WIRE
PANEL DOES NOT
HAVE A CENTER
MAIN BREAKER
EXISTING BUILDING
GROUNDING
ELECTRODE SYSTEM
FROM OPTIMIZERS TO INVERTER/DC DISCONNECT:
AMBIENT TEMPERATURE = 47°C
TEMPERATURE ADDER FOR CONDUIT OFFSET FROM ROOF BY34" MINIMUM = 220C
ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR go°C INSULATED
CONDUCTOR AT 470C + 220C = 690C = o.58
Isc =15.00 A
15.00 A/o.58 = 25.86 A
NUMBER OF CURRENT CARRYING CON DUCTORS I N CON DUIT = 4
ADJUSTMENT FACTOR PER TABLE 310.15(B)(3)(a) FOR CONDUIT
FILL (4-6 CONDUCTORS IN CONDUIT) = o.8o
25.86 A/o.8o = 32.33 A
SELECT WIRE SIZE WITH AMPACITY GREATER THAN 32.33 A,
USE 10 AWG THWN-2 COPPER WIRE WITH AN AMPACITY OF 4o A
SELECT CONDUIT FOR (4)10 AWG THWN-2 & (1) 8 AWG GROUND = Y4" EMT CONDUIT
FROM THE INVERTER TO THE SUB PANEL:
ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(2) FOR go°C INSULATED
CONDUCTOR AT 470C = o.82
Ic = 31.25 A
31.25 A/o.82 = 38.11 A
SELECT WIRE SIZE WITH AMPACITY GREATER THAN 38.11 A,
USE 8 AWG THWN-2 COPPER WIRE WITH AN AMPACITY OF 55 A
SELECT CONDUIT FOR (3) 8 AWG THWN-2 & (1) 8 AWG GROUND = Y4" EMT CONDUIT
SCOPE OF WORK:
LUKE ROOFING
INSTALL (23) Q.CELLS Q.PEAK-G4.1 305 SOLAR ELECTRIC MODULES AND
NOTICE:
INCORPORATED
(23) SOLAREDGE P32o DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY
ANY CHANGES TO OR USES OF THESE
26o81 MERIT CIRCLE #125
COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE,
DOCUMENTS/DRAWINGS WITHOUT THE
LAGUNA HILLS, CA 92653
JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL
WRITTEN CONSENT OF ]ENNIFER KEMME OR
PH: 714.633.8798
(1) SOLAREDGE SE6000H-US [S11] INVERTER WITH INTEGRATED DC DISCONNECT,
SCOTT HARRIS ARE STRICTLY PROHIBITED.
(1) SQUARE D DU222RB AC DISCONNECT, AND INSTALL OCPD IN SUB PANEL.
GARY DEAN LUKE B - 672569
DATE: 8/29/18
PLANS PREPARED BY:
JENNIFER KEMME
PH: 909.754.8300
SHEET
3 OF 4
»n-)-,P\/
HOMEOWNER: MIKETERRY
PH: 949.466.0900
APN: 646-160-007
ADDRESS: 781o1 SAN TIMOTEO STREET
LA QUINTA, CA 92253
CAUTION
POWER TO THIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING SOURCES
WITH DISCONNECTS AS SHOWN.
N SOLAR ARRAY
r (ON ROOF)
PHOTOVOLTAIC
SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
INVERTER & DC DISCONNECT
PV SYSTEM DISCONNECT
FOR UTILITY OPERATION
SERVICE POINT &
UTILITY METERING
ADDRESS: 78101 SAN TIMOTEO STREET, LA QUINTA, CA 92253
10 BL INS IALLED ON THE OUTSIDE COVER
OF THE MAIN SERVICE DISCONNECT:
NOTICE:
ANY CHANGES TO OR USES OF THESE
DOCLIMENTS/DRAWINGS WITHOUT THE
WRITTEN CONSENT OF JENNIFER KEMME OR
SCOTT HARRIS ARE STRICTLY PROHIBITED.
SYSTEM SIGNAGE
ALL SIGNAGE SHALL BE REFLECTIVE, UV RESISTANT
PLASTIC, RED IN COLOR WITH WHITE LETTERING, AND
ATTACHED WITH WEATHERPROOF ADHESIVE OR
OTHER APPROVED METHOD. ALL LETTERS SHALL BE A
MINIMUM OFY" HEIGHTAND ALL CAPITALIZED.
ALL CONDUIT, JUNCTION BOXES AND OTHER ENCLOSURES
SHALL BE MARKED AT 1o' MAX INTERVALS AND AT ALL
BENDS, TERMINATIONS, SPLICES OR CONNECTIONS WITH
"WARNING: PHOTOVOLTAIC POWER SOURCE".
690.5(C) - INVERTER
705.12(D)(7) - PANELBOARD
CEC 690.31(E)(3)
AND CFC 605.11.1.2
- DC CIRCUITS, JBOXES, ETC.
ITY OF LA QUIN1
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE BY
690.17/690.54 - AC DISCONNECT
690.17/690.53 - DC DISCONNECT
690.56(B)/705.10 - SERVICE
690.35(F) - UNGROUNDED DC CIRCUITS
SCOPE OF WORK:
LUKE ROOFING
INSTALL (23) Q.CELLS Q.PEAK-G4.1305 SOLAR ELECTRIC MODULES AND
INCORPORATED
(23) SOLAREDGE P32o DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY
26o81 MERIT CIRCLE #125
COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE,
LAGUNA HILLS, CA 92653
JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL
PH: 714.633.8798
(1) SOLAREDGE SE6000H-US [S11] INVERTER WITH INTEGRATED DC DISCONNECT,
(1) SQUARE D DU222RB AC DISCONNECT, AND INSTALL OCPD IN SUB PANEL.
GARY DEAN LUKE B - 672569
DATE: 8/29/18
PLANS PREPARED BY:
JENNIFER KEMME
PH: 909.754.8300
SHEET