BPAT2018-0098Tit�t D � Qaba VOICE (760) 777-7125 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Permit Type/Subtype: PATIO COVER/CITY STANDARD/PRE-ENGINEERED - OPEN Owner: Application Number: BPAT2018-0098 KOCEJA, VICKIE Property Address: 44900 VIA ALONDRA 44900 VIA ALONDRA APN: 604590009 LA QUINTA, CA 92253 Application Description: KOCEJA / 168SF TRELLIS DURALUM (PATIO COVER AT REAR YARD Property Zoning: Application Valuation: $2,300.00 Applicant: I'Alf1���ll^ Contractor: Al CS PATIO COVERS R A V CS PATIO COVERS 82857 WHEATLEY COURT f % 82857 WHEATLEY COURT INDIO, CA 92201 8101 �30 i INDIO, CA 92201 - (760)625-4225 p Llc. No.: 1004320 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: D03 License No.: 1004320 _ Date: l LI X 7 Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: () I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). O I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Date: 12/13/2018 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrler: EXEMPT Policy Number: OLI certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date; Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application, 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City and County ordinances and state laws relating building construction, and hereby authorize representatives of this city to enter u the above -mentioned property For Inspection purposes. 7 Date:" I / Signature (Applican olfAg 78-495 CALLE TAMPICO T4ht DVOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Permit Type/Subtype: PATIO COVER/CITY STANDARD/PRE-ENGINEERED - OPEN Owner: Application Number: BPAT2018-0098 KOCEJA, VICKIE Property Address: 44900 VIA ALONDRA 44900 VIA ALONDRA APN: 604590009 LA QUINTA, CA 92253 Application Description: KOCEJA / 168SF TRELLIS DURALUM (PATIO COVER AT REAR YARD Property Zoning: Application Valuation: $2,300.00 II Applicant: t U Contractor: CS PATIO COVERS �� CS PATIO COVERS 82857 WHEATLEY COURT 7 82857 WHEATLEY COURT INDIO, CA 92201 DEC 13 2018 INDIO, CA 92201 Tv I��T (760)625-4225 CIIYOFAQUIIV A Llc. No.: 1004320 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class:,D03 License No.: 1004320 Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement Is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). () I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). () I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Address: Date: 12/13/2018 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: EXEMPT Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. Date: Signature (Applicant or Agent): Date: 12/13/2018 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: Applicant: CS PATIO COVERS 82857 WHEATLEY COURT INDIO, CA 92201 BPAT2018-0098 44900 VIA ALONDRA 604590009 KOCEJA / 168SF TRELLIS DURALUM (PATIO COVER AT REAR YARD $2,300.00 Owner: KOCEJA, VICKIE 44900 VIA ALONDRA LA QUINTA, CA 92253 Contractor: CS PATIO COVERS 82857 WHEATLEY COURT INDIO, CA 92201 (760)625-4225 LIc. No.: 1004320 Detail: 168SF SOLID PATIO COVER AND [4]ELECTRICAL FIXTURES AT REAR YARD [DURALUM] 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT SERVICES 101-0000-42403 0 $106.72 DESCRIPTION ACCOUNT CITY AMOUNT SERVICES PC 101-0000-42600 0 $53.36 Total Paid for ELECTRICAL: $160.08 DESCRIPTION ACCOUNT CITY AMOUNT PATIO COVER, STD, OPEN 101-0000-42404 0 $107.27 DESCRIPTION ACCOUNT QTY AMOUNT PATIO COVER, STD, OPEN PC 101-0000-42600 0 $105.66 Total Paid for PATIO COVER / COVERED PORCH / LATTICE: $212.93 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $0.50 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.50 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 ta QU11kra - GFN] 4 h, D PSF.RT PERMIT # . PLAN LOCATION: Project Address: I goo Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN#: ,f r� "CIr I�r[O` F Gf Applicant Name: �( ' �� na �j c, Address: e City, ST, Zip: Telephone: 76 U Email: Valuation of Project Contractor Name: C S RCtiHo a �l e.r S New SFD Construction: Address: �� 0 5 W C _ Conditioned Space SF City, St, Zip C� Z I Garage SF Telephone: -7(D p ZS Z (Z Patio/Porch SF Email: Fire Sprinklers SF State Lic: )q3-Z_0 City Bus Lie: % 3 r Z_ Arch/Eng Name: Construction Type: K� tC) �Occupancy: Grading: Address: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: / / ,-& &- New Commercial / Tenant Improvements: Address: Wff A Total Building SF City, ST, Zip to F �z 5 Construction Type: Occupancy: Telephoner i3 Email: 78495 CALLE TAMPICO LA QU I NTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal Plan Sets Req'd Rec'd Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License W Clear r' 7 M. f f y Zoery @W18 , DIgrta9t �.: rr Tem►s Report a map error Koceja Vicki A 44900 Via Alondra La Quinta, CA 92253 " Riverside County APN: 604-590-009 Built: 2004 Sq Ft: 2,645 Type: Residential I SFR Beds: 3 Baths: 3 Order Customer Service CostsFIrstTM Add to Farm List Report Name Actions Available Allowance Combined Report Edit I Run ■ Property Profile Run 62 100 Transaction History Run 76 100 V asp data La Quinta Del Oro r-% _ W ! A Vili f i i Iututy Association La Quinta Memorandum -DRAFT Del Oro To: Vickie Koceja A Annn 28'_ Af_- r "5­_VW VI=n1Ul IUIQ From: Architectural Landscape Committee Copy: LQDOCA Board & Avail Property Management Date: August 24, 2018 Subject: Application For ArchitecturallLandsca a Modification Approval AALMA A/Al4n r_s___+_ 11,-LnLgl 1.71U! ! The LQDOCA Architectural/Landscape Committee (A/L Committee) has reviewed your request for an extension to install two (2) rear pergolas for the above captioned application including Drawing 1, 8 Architectural Renderings and 3 Spec Sheets dated February 20, 2017 by Desert Landscape Associates. Thp AAI MA anxfancinn is 1--._ fn% -- .rkj �­j ,ca4jl p-uiaS wim meoiiowing notes & conditions: Ensure there are no encroachments in the 10.0' Public Utility Easement (PUE) along Via Alondra and the 3.0' Verizon Easement within each Side Lot line. • Ensure proper lot drainage and slopes. • Per LQDOCA Architectural Guidelines IV-B, the pergola materials shall be alums -wood, wood, masonry or stucco with aluma-wood matching the front neranlas nrafPrrPH The Onde material cannot be plastic or plastic webbing. - - - - ■ The proposed dimensions and setbacks comply with City of La Quinta requirements: a Lot setbacks-Front-20' (back of curb), Side-5' and Rear-, 5' o Pergola Height = 7.7' versus 12' maximum o Pergola Coverage 24%-250 ftz/525 ft'allowed (15' x 70' x 0.5) • Ensure compliance with City of La Quinta Municipal Code and Regulations including but not limited to Title 9 Zoning and in particular 9.60.040-Patio Covers, decks and play equipment. • •—__ •::.....�.�a,. vvH.Ii;II v-v udyb afllJ Wf1iiJICICLi Wllllln izu nays. • No deposit required. Submitted by: 1."'E IVE Mark Brown Chairperson DEC 0 6 2018 CITY OF LA QUINTA COMMUNITY DEVELOPMENT Page IofI ter_ Lu �_ P r IGt? . uo Liz -4 LEI) Li-,hts 4 5r 4�- L J � Y((Ae(f 6p C-Pr L LA— tui c,;,i 7(�,2— W 3 L/ 2- Y r it a'q p-Y �a rl q pa sT i5ccl`n Tr+j''a/ �Gn a 5 .t> CFpaj � -P-�p-4T2-ola - 00 "Fd UTY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE BATE Z ! 2 %cl% BY 165YFu t> �14TIo Cov-'tl A (y,)eL 4ec-rat c,Al 4W.5c 6 51R K( Coves $PATWIg •0048 44C(pp V Ilk 1�4*0tJ1 A c. RY ski r pa r bears = 1 4r PATIO COMER SYSTEM AS MFG. BY: DURALUM PRODUCTS, INC. b POINT OF CONTACTS ► /�/ Las CL_. INFORMATION REQUESTS SHALL BE DIRECTED AS FOLLOW:-�EE,�tIYG CONTRACTORS: PLEASE CONTACT DURALUM 26030 ACERO SUITE 200 PHONE: (949) 305.1150 BUILDING DEPARTMENTS: PLEASE CONTACT 4STEL ENGINEERING MISSION VIEJO, CA 92691 FAX (949) 305-1420 HOME OWNERS: PLEASE REQUESTANY INFORMATION THROUGH YOUR CONTRACTOR STRUCTURAL ENGINEER OF RECORD: DUSTIN K- ROSEPINK, SE 5885 POINT OF CONTACT: MARIE-DOMINIQUE SETA SE 5987 DESIGN PARAMETERS GOVERNING CODES: - THE DESIGN a ATTACHED AND FREESTANDING COVERS SHOWN IN THIS REPORT COMPLIES WITH THE FDUDWING CODES: . 20121201512018INTERNATIONAL BUILDING AND R ESCEHITAL CODES .2013I2D36 CALIFORNIA BUILDING AND RMDENTiALCODES, - ASCETSE 17-ID and 7.16 MIN I MUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, - 2015 ALUMINUM PESO MANUAL LIVE LOADS DESIGN PARAMETERS: IT IS THE RE5P0 ISi OF HE ENITIYSUBMIITTHGTRE DRAWINGS FOR THIS PROJECT TO VERIFY LIVE LOADS WITH THE LOCAL AUTHORITY HAVING JURISDICTION 1. IN RESIDENTIAL APPUCATIONS, ROOF LIVE LOAD CAN GENERALLY BE TAKEN AS 10 PSF PER IRC/ OCAPPENDIX H, SECTION AR1D51 OR IBC I CKAPPENDIX L SECTION 305.1 2, IN COMMERCIAL APPLICATIONS, ROOF LIVE LOAD CAN GENERALLY BE TAKEN AS 20 PSF PER IBC ICBC CHAPTER I.6 WINO SPEED DESIGN PARAMETERS: 1. THE FREESTANDING AND ATTACHED CDVEKS NOTED HEREIN ARE DESIGNED AS "OPEN 5TRUCTURTS,- IN ACCORDANCE WITH ASCE/SEI7. 2- FREESTANDING COVERS SHALL NOT BE ENCLOSED WITH ANY TYPE OF SOLID OR MESH MATERIAL, UNLESS SPECIFICALLY DESIGNED BY A REGISTERED PROFESSIONAL ENGINEFFL 3, COVERS SHALL NOT BE INSTALLED IN AREAS NEAR HILLS, RIDGES AND ESCARPMENTS AS DEFINED IN ASCEISEI7. SECTION 261, UNLESS $M SPECIFIC ENGINEERING IS PROVIDED VALIDATING THE WIND LOAD USED, 4, THE BASIC WINO SPEEDS CONSIDERED IN THIS REPORT ARE III%120,13D MPH, EXPOSURE5 BAND C (BASED ON THE 2012IBC 2OW2028 IWIRC, AND 2OW2M 6. OV4CRC). 5- FDR USE WITH THE Z012 IRC AND 203a CRC DIVIDE THE ABOVE MENTIONNED WINO SPEEDS BY SQRT(0,% CBC I IBC'A [ND SPEED I 11O MPH I 12O MPH 13O MPH EOL4VALEHTCRUIRCWIND SPEED I 85MPH-` 93MPH 1D1MPH EXAMPLE: IF2032 IRC DR 2013 CRC WIND SPEED IS 85 MPH, THE PATID COVER CON5TRVCnON SHALL BE BASED ON 8S MPH ISAR DA)-110 MPH. SNOW LOADS DESIGN PARAME"EERS: IT IME RESPONRIN ITY OF THE ENTITY SUBMITTING THE ORAWLNGS FOR THIS PRCUECT TO VERIFY SNOW LOADS WITH THE LOCALALIDIORITY HAVING JURISDICTION 1. GROUND SNOW LOADS P8 ARE LISTED IN THETABLE5 OF THIS REPORT. RAT ROOF SNOW LOADS PI WERE USED TO GENERATE THOSE TABLES, PER ASCE 7 EQUATION 7.3-1. USING CL-10AND C1-1.2. THE FOLLOWING TABLE CAN BE USED TO DFIFRMW THE DESIGN SNOW LOADS USED IN THE SIGN; GR[OUNDSNOW LOAD (ps€] (AS REFERENCED 114 THIS REPORT) 10 20 25 1 30 40 1 50 ROOF SNOW LOAD (pso (AS USED IN CALCULATIONS) 10 20 21 1 25.2 33.6 1 42 2. WHEN THE LOCALAH) HAS SPECIFIED A FLAT ROOF SNOW LDAD TO BE USED AT THE SITE, THE CONTRACTOR SHALL USE THE TABLE ABOVE ID FIND THE EQUIVALENT GROUND SNOW LOAD TO BE USED WHEN USING THIS REPORT. WHEN NO ROOF SNOW LOAD 6SPECIFIED BY LOCAL AW, USE THE CODE SPECIFIC GROUNDSNOW LOAD VALUES AT THE SITE WHEN USING THIS REPORT, 3. WHERE SNOW LOADS OCCUR, THE CONTRACTOR FOR THIS PROJECT SHALL VERIFY WITH THE LOCAL AUTHORITY HAVING JIIRGDICNON WHERE DESIGN FOR SNOW DRIFTING I DR SUDRVG IS REQUIRED PER ASCE 7•10 AND 7.16, SECTOR 7.7 AND 7.8. 4, DESIGN FOR SNOW DRIFT AND5U01NG HAVE BEEN CONSIDERED IN THIS SET OF DRAWINGS FOR ATTACHED COVERS, WHERE SNOW LOADS DRIFTING AND / OR SLIDING OCCUR REDUCTION FACTORS PER SHEET$11 OR E2-1SHALL BE APPLIED TO THE STRUCTUREE, S. DESIGN FOR SNOW DRIFTANO 5UO1NG FOROETACHED COVERS 15 BEYONDTHE SCOPE OFTHIS REPORT AND REQUIRES SITE SPECIFIC ENGINEERING, INSULATED ROOF PANEL IIRP) DESIGN PARAMETERS TO BE USED WITH IAPMO 0505: APPLIED PRESSURE LOADING TO BE USED IN IAPMO OSOS WIND (MPHJ ROOF LIVE J GROUND SNOW LOAD (psf) AS REFERENCED IN THIS REPORT 10 20 7S- 30 40 50 110E 12D3,130B,11 UDC 15 25 25 30 40 45 13013 20 25 25 30 40 45 GENERAL NOTES DRAWING NOTES: 1. THE DRAWINGS AND SPECIFICATIONS SHOWN REPRESENT THE FINISHED STRUCTURE, UNLESS OTHERWISE NOTED, AND DO NOT INDICATE THE METHOD OFCONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 2. THE APPROVED SET OF DRAWINGS AND SPECIFICATIONS SHALL BE KEPT AT THE JOB SITE AND SHALL BE AVAILABLE TO THE AUTHORIZED REPRESENTATIVES OFTHE BUILDING AND SAFETY DEPARTMENT. THERE SHALL BE NO DEVIATION FROM THE APPROVED PLANS AND SPECIFICATIONS WITHOUT AN APPROVED CHANGE ORDER. MATERIAL SPECIFICATIONS: 1. ALTERNATE ALUMINUM ALLOYS MAY BE SUBSTITUTED FOR THOSE SHOWN, PROVIDEDTHEY ARE REGISTERED WITH THE ALUMINUM ASSOCIATION AND HAVE EQUAL OR GREATER YEILD AND ULTIMATE STRENGTHS 2. CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF2,500 POUNDS PER SQUARE INCH. 3. EMBEDDED STEEL MEMBERS SHALL BE HOT -DIPPED GALVANIZED, AND CONFORM TO A50D GRADE B. ROLL FORMED STEEL MEMBERS SHALL CONFORM TO A653-SS(STRUCTURALSTEEL) GRADE 50 G60. 4. BOLTS: ALUMINUM BOLTS SHALL BE 2024-T4;STEEL BOLTS SHALL BE ASTIM A-307. ALL BOLTS SHALL HAVE STANDARD -CUT PLATED WASHERS. 5. SCREWS: ALL SCREWS ARE SELF DRILLING (SDS) OR SHEET METALSCREWS(SMS)IN CONFORMANCE WITH ICC-ES ESR 1976,ICC-ESR 3006, OR APPROVED EQUAL 6. FASTENERS TO WOOD: WOOD AND LAG SCREWS ARE REQUIRED TO BE INSTALLED IN ACCORDANCE WITH THE 2015 NATIONALDESIGN SPECIFICATIONS, INCLUDING PRE -DRILLING OF HOLES. 7. POST -INSTALLED ANCHORS: POST -INSTALLED ANCHORS USED SHALL BE SIMPSON STRONG TIE STRONG BOLT 2, STAINLESS STEEL(ICC-ESR 3D37) OR EQUAL 8. ALL COMPONENTS MANUFACTURED OR SUPPLIED BY DURALUM AND DESCRIBED IN THIS DOCUMENTS ARE INTERCHANGEABLE, PROVIDEDTHEY ARESELECZED APPROPRIATELYTO SUPPORTTHE LOADING THEY ARE SUBJECT TO. 9. THE SELF WEIGHT OF THE PATIO COVER COMPONENTS IN THIS REPORT CAN BE CALCULATED FROM THEIR SECTION PROPERTIES.THE SOLID COVERSVARY IN WEIGHT FROM ABOUT 1 P5FT0 ABOUT 3 PSF. 10. ROOF INSULATED PANELS (WHERE OCCURS). SEE53.2. SOLAR PANEL INSTALLATION: INSTALLATION OF SOLAR PANELS ON TOP OF THIS STRUCTURE HAS SPECIFIC REQUIREMENTS. PLEASE CONTACT DURALUM PRIORTO ORDERINGTHE PARTS AND SUBMITTING DRAWINGSTO LOCAL AUTHORITY HAVING JURISDICTION. FOOTINGS: 1. ALL NEW CONCRETE FOOTINGS SHALL BEAR ON FIRM, NATURAL, UNDISTURBED SOIL OR CERTIFIED FILL 2. DESIGN VERTICAL SOIL BEARING PRESSURE 15 1,50D POUNDS PER SQUARE FOOT. 3. DESIGN LATERAL SOIL BEARING PRESSURE IS 20D POUNDS PER SQUARE FOOT PER FOOT OF FOOTING DEPTH. (EQUALS IDD PSF/FT x 2 PER TABLE 1806.2 AND SECTION 1806.3.4) 4. THE BOTTOM OF FOOTINGS SHALL EXTEND BELOW THE FROST DEPTH. CONTRACTOR TO VERIFY FROST DEPTH WITH AUTHORITY HAVING JURISDICTION. SLAB ON GRADE USED AS A FOUNDATION SYSTEM: 1NACCORDANCE WTTH IRCIERCAPPENDIX H, SECTION AHSDS.2, AND IBC/IRC APPENDIX I, SECTION 1105.2, IN AREAS WITH A FROST DEPTH EQUALTOZERO, ATTACHED COVERS FOR RESIDENTIAL USE MAY BE SECURED TO AN EXISTING CONCRETE SLAB PROVIDED THE FOLLOWING: 1. THE SLAB ON GRADE IS AT LEAST 31/2 INCHES THICK 2. THE MAXIMUM DEAD AND LIVE/SNOW LOAD AT EACH COLUMN IS 750 POUNDS, 3. THE SLAB ON GRADE SHALL BE A MINIMUM OF 10'-U'WIDE BYTHE MAXIMUM COLUMN SPACING MEASURED ATTHE COLUMN. WITHIN THIS MEATHERE SHALL BE NO CRACKS WIDERTHAN 1/4- OR CONTROL/EXPANSION JOINT DEEPER THAN 1/2". 4. THERE SHALL BE A 6" MINIMUM DISTANCE BETWEEN ANY ANCHOR BOLT AND A SLAB EDGE, CRACK WIDER THAN 1/32- OR CONTROIJEKPANSIDN JOINT DEEPERTHAN 1/2-. DESIGN FOR PATIO COVERS SUPPORTED ON CONCRETESLAB ON GRADE I51N ACCORDANCE WITH 2O12/2015/201B IRC AND 2013/2016 CRCSECTION AH105.2 FOR 10 PSF RESIDENTIAL CONSTRUCTION, AND ACI 318-14 FOR 20,25 AND 30 PSF RESIDENTIALAND COMMERCIAL CONSTRUCTION. NOTES TO LOCAL AUTHORITY HAVING JURISDICTION AND ENTITY SUBMITTING DRAWINGS FOR APPROVAL USE OF THIS SET OF PLANS FOR A SITE SPECIFIC PROJECT: L NOT ALL PAGESOF THE IAPMO REPORT WILL BE USED FOR A SITE SPECIFIC PROJECT. EACH PROJECT SUBMITTED TO THE LOCAL AUTHORITY HAVING JURISDICTION SHOULD INCLUDE ONLY THE PERTINENT SME-SPECIFIC STRUCTURAL COMPONENTS LOCATED WITHIN THIS IAPMO-LISTED EVALUATION REPORT. 2. ALL ITEMS PERTAINING TO EACH INSTALLATION (TYPE OF ROOF PANEI, HEADER SPAN, COLUMN SIZE, CONNECTION DETAILS ETC) SHALL BE CIRCLED AND CLEARLY IDENTIFIED BYTHE ENTITY SUBMITTING THE DRAWINGS FOR APPROVAL 3. PLEASE NOTE THATASTEL ENGINEERING GENERATED AND STAMPED THE ORIGINAL IAPMO REPORT AS AVAILABLE FROM IAPMO DIRECTLY, BUT WAS NOT INVOLVED IN MAKING ANY SITE SPECIFIC SELECTIONS OR ANOTA71ONS ON THOSE DRAWINGS. ANY HANDMARKING OR HIGHLIGHTING ON THE SITE SPECIFIC SET OF DRAWINGS AREIHE RESPONSIBILITY OFTHE ENTITY SUBMITTING THE DRAWINGS FOR APPROVAL 4. EACH INSTALLATION SHALL BEAR AN IDENTIFYINGTAG INDICATING THE NAME AND ADDRESS OFTHE MANUFACTURER DESIGN LOADS AND ENCLOSABILITY. S. THE ORIGINAL IAPMO REPORT BEARS AN ELECTRONICSTAMP FROM 45TEL ENGINEERING, AND A WET STAMP IS NOT REQUIRED IN ACCORDANCE WITHTHE REGULATIONS STATED BYTHE PROFESSIONAL BOARD OF ENGINEERS. 6. A COLOR COPY OF THE ORIGINAL PAGES FROM THE IAPMO REPORT 15 NOT REQUIRED. A COLOR COPY OF THE CONSTRUCTION DOCUMENTS MAY BE REQUIRED IF SELECTIONS WERE MADE IN A WAY THAT WILL NOT BE VISIBLE ON A BLACK AND WHITE COPY USE LESSER SPAN FROM IAPMO.0505 FROM ALL LOAD TYPES (LIVE, WIND, SNOW) FORAPPLLED PRESSURE LOADING FROMTABLE ABOVE AT A MINIMUM, SUBMISSION FOR A BUILDING PERMIT MUST INCLUDE THE FOLLOWING INFORMATION FROM THIS EVALUATION REPORT:'�� 1. TITLE SHEET AND GENERAL NOTES,60.1 SEISMIC LOAD DESIGN PARAMETERS: 2. STRUCTURAL CONFIGURATION (i.e. SOLID OR LATTICE ROOF, FREESTANDING OR ATTACHED). Sl.x OR L1x SEISMIC DESIGN BASE SHEAR, 17 POUNDS PER UN EAR FOOT PER WIDTH OF COVER CONSIDERING THE HOLLOWING DESIGN PARAMETERS: 3. BASED ON THE REQUIRED DESIGN LOADS, SITE -SPECIFIC RAFTER AND/OR PANEL SPAN TABLES. - W 1- SITE CLASS:O 4. TYPE OF HEADER, POST TYPE & QUANTITY, FOOTING SIZE (WHERE REQUIRED) BASED ON THE SITE -SPECIFIC DESIGN LOADS. 2,- 2, SEISMIC DESIGN CATEGORY:E S. APPROPRIATE STRUCTURAL DETAILS. ui II.L 1 MAPPED SPECTRAL KWONSECOEFFLCIENTS:Ss =1.50,51=U.S.Sds =1.D,Still =DSO 6. OTHER DOCUMENTATIONTHAT MAY BEREQUIREDBYTHELOCAL AUTHORITY HAVINGIURISDICTION,SUCH ASASITE PLAN. Od 0 A. RESPONSE MODIFICATION FACTOR, R-11S 7. SEE Slx DR Ll.x SH HOE%. S. RISK CATEGORY II 6. THE PATIO COVER STRUCTURES DETAILED IN THIS SET OF PLANS ARE 1N COMPLIANCE WITH ASCE 7.10SFCTION 12.8,13, AS RESULT, THIS SET OF PLANS CAN BE USED ATAW SITE WITH Ss a 1.50, CONSIDERING Ss = JOB NAME' 1,50 WHEN DESIGNED PER 2D12I201S IBC/IRCAND 201312016 CBCICRC, 7. THE PATIO COVER STRUCTURES DETAILED IN THIS SET OF PLANS ARE IN COMPLIANCE VMASCE 7.26 SECTION 1221.3.AS A RES11LT, THIS SET OF PLANS CAN BE USED AT ANY SITE WITH lALS 41A28, CONSIDERING JOB ADDRESS: LO tA- S& FOR SITU WITH Sds<l.0, USE Sds. FOR SITES WITH Sds4 428, IT IS ACCEPTABLE TO REDUCE THE SEISMIC LOADS USING 0.7 Sds INSTEAD OF SdL WFA0 ! OTHER DESIGN PAIIAMETERS: Lu 1. DESIGN LOADS COMBINATIONS ARE IN ACCORDANCE WITH IBC AND CDC SECTION 16M5.1. WIND LOAD: L 2. ALL APPLICABLE REDUCTION FACTORS DETAILED IN THIS REPORT ARE CUMULATIVE 3- SOLID AND LATTICE ALUMINUM COVERSARE CLASS A ROOF ASSEMBLY IN ACCORDANCE WITH SECTION MC1505.2, EXCEPTION 2. 0 DESIGN ASSUMPTIONS: LIVE/SNOW LOAD: -� S 1. MINIMUM ROOF SLOPE FOR SOLID ROOF PANELS WITH DECK:5EE DETAIL IEYS3.2 2. MINIMUM ROOF SLOPE FOR SOLID ROOF PANELS WITH OUMPANEL: SEE DETAIL 1A1S3.2 1 MAXIMUM ROOF SLOPE FOR ALL STRUCTURES IS 3 DEESnES Af 4. THE "LENGTH OF STRUCTURE'SHALL BE TAKEN AS THE CONTINUOUS DISTANCE MEASURED ALONG THE MISTING BUILDING WALL FROM ONE END OF PATIO COVER SUPPORT REAM TO THE OTHER, INCLUDING ANY BEAM SPLICES, THE STRUCTURE LENGTH SHALL BE OETERMINEDTHIS WAY REGARDLESS OF ROOF COVERING TYPE, INCLUDING COMRIILA.TION ROOFS WITH BOTH TRELLIS AND DECK ROOF USED ONTHESAME SHEET INDEX CONTINUOUS PATIO COVER STRUCTURE HOWEVER, OPEN LATTICE PORTIONS OF THE STRUCTURE SHALL NOT BE COVERED BY RODF DECK PER IAPMO 195. 5. CALCULATIONS FOR MAXIMUM SPANS WHEN ATTACHING TO AN EX157ING ROOF OVERHANG, AS SHOWN ON TABLE I ONS6.1 AND/OR I -SA, ARE ASSUMING THAT THE EX15ITNG WOOD RAFTERS OR TRUSSES ARE SEE SHEET S1.x QR Lt,x FOR SHEET INDIX. DOUGLAS FJR-LARCH ND2. THIS TABLE CAN ALSO BE USED FOR OTHER WOOD SPECIES WITH Fh Z 900 Psi AND Pv L 180 PSI. ALL UNUSED SHEETS SHALL BE REMOVED FROM THIS SET OF DRAWINGS. u It (E) BUILDING SOLID COVER CONNECTION Li TO BLOT SEE NOTE 2 w � i i I Ld z . ! ! COL, TYP N z i SEE NOTE 4 0 0 w O z i � � I I I I SOLID COVER CONNECTION U w Ld N TO BEAM SEE NOTE 2 I I ; a I I BEAM CLEAR SPAN L BEAM CLEAR SPAN LENGTH 'L' SEE NOTE 1 C PLAN VIEW NOTES: .1. PATIO COVER DIM A LENGTH OF STRUCTURE 'L' SHALL NOT BE LESS THAN ITS PROJECTION 'P'. SEE DESIGN ASSUMPTION NOTE 10 FOR PATIO COVERS CONSISTING OF SOLID COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAMS ADJACENT CLEAR SPAN. EXCEPTION= NO OVERHANG ALLOWED AT I BEAMS CONNECTED TO SIDE OF COL D. SOLID COVER OVERHANG 'OH' SHALL NOT EXCEED 25% OF BOTH DECK & IRP SOLID COVER'S ADJACENT CLEAR SPAN, (OR 24• MAX. AT IRP, WHICHEVER IS LESS). E. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN; • TRIB (Bext)= Y2 ADJACENT DECK CLEAR SPAN @ RIGHT + DECK OH @ LEFT •TRIB (BLDG)=h ADJACENT DECK CLEAR SPAN A SEE SHEET S3.1A AND S3.3 FOR DECK PROFILES AND MAXIMUM SPANS. B. SEE SHEET S3.2 FOR DURAPANEL INSULATED STRUCTURAL SANDWICH PANELS MAXIMUM SPANS. C. SEE SHEET S2.1 FOR REDUCTION OF SOUD COVER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET S3.2 FOR CONNECTION OF SOLID COVERS TO SUPPORTING BEAMS. E. SEE SHEETS S3.2&S6.1 FOR CONNECTION OF SOLID COVERS TO (E) BUILDING. F. MINIMUM SLOPE OF SOLID DECK COVERS TO BE PER SHEET S3.2. G. MINIMUM SLOPE OF DURAPANELS TO BE PER SHEET S3.2. OH IE 1 3. BEAMS SOLID ROOF PANEL SEE NOTE 2 CONCRETE FTG, SEE NOTE 5, TYP ISOMETRIC VIEW J 3/32"=1'-O" A SEE SHEETS S4.1 & S4.2 FOR BEAM PROFILES. B. SEE SHEET S4.2 FOR FAN BEAM WHERE OCCURS. C. SEE SHEETS S7.1 AND SB.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPANS. D. SEE SHEET S2.1 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. E. SEE SHEETS S6.x FOR BEAM CONNECTIONS & DETAILS. F. SEE SHEETS S5.1 AND S6.3 FOR BEAM SPUCE DETAIL WHERE REQUIRED. BEAM SIMPLE SPLICE, WHEN NEEDED, SHALL BE LOCATED IMMEDIATELY ABOVE AN INTERIOR COLUMN. NO BEAM SPLICE SHALL BE PERMITTED BETWEEN COLUMNS OR ON TOP OF AN EXTERIOR COLUMN. 4. COLUMNS A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBERS OF POSTS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET S4.3 FOR COLUMN PROFILES. C. SEE SHEETS S7.1 AND SB.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS S6.x AND S7.x FOR POSTS CONNECTIONS & DETAILS. FWA;I�L�II�];f A. SEE SHEET S7.1 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEET S8.xx.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED. C. SEE S7.1 FOR ALTERNATE FOOTING SIZES. D. SEE 8/S7.1 FOR ATTACHED PATIO COVER SUPPORTED ON SLAB ON GRADE. TABLE 1 MINIMUM NUMBER OF POSTS REQUIRING ATTACHMENT PER 31S6.3 OR 3/11.6.3 WITH 2 x 6.5 x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) TRIG WIDTH WIND SP EE ❑ AN UR 1106 110C 12021 12M 133E 137C 5 2 2 2 3 3 3 G 2 3 3 3 3 4 72 3 3 4 3 4 S' 3 3 3 4 4 5 9 3 4 4 4 4 5 1D 3 4 4 5 5 6 11' 4 4 4 5 5 6 12 4 5 1 S 6 5 7 WITH 2x6.5x0.042SIDE PLATES (SIDE PLATE TYPE SP4) TRIB WIND Sp E E DANa OPOSUR WIDTH 1105 110C 1 12M 120C 1336 13DC 5' 2 2 2 2 2 3 6' 2 2 2 3 3 3 7 2 3 3 3 3 4 a 2 3 3 4 3 4 9 3 3 3 4 4 5 1C! 3 4 4 4 4 5 11' 3 4 4 5 5 6 12 3 4 4 5 5 5 NOTES: 1. NUMBER OF POSTS SHOWN IN THIS TABLE IS A MINIMUM. ADD POSTS AS REQUIRED TO ENS URETHAT THE 'MAX POST SPACING (SPAN)" SHOWN ON SHEETS SS-xx-x OR LB.xx.x IS NOT EXLEEDED. 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL 3186.3 OR 31L6.3. 3.. THIS TABLE DOES NOTAPPLY IFTHE SIDE PLATES ARE PROVIDED FOR AESTHETICAL PURPOSES ANDTHE BEAM IS CONNECTED TO THE COLUMN DIRECTLY OR WITH A BRACKET PER S6.3 OR L6.3. A TABLE i - MINIMUM NUMBER OF COL REQUIRING TOP ATTA HMENT PER 3/S63 OR 3/1-63 SHEET INOEX - SOLO PANEL STRUCTURES TYPE A GDA -TITLE SHEET, DESIGN LOADS, GENERAL NOTES S1.1 -SOLID PANEL STRUCTURES: TYPE A S2.1 -SOLID PANEL STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFTAND SLIDING S3.1A -SOLID PANEL STRUCTURES: ATTACHED COVERS MAXIMUM SPANS AND MINIMUM FASTENERS S3.2-SOLID PANEL STRUCTURES: CROSS SECTIONS S3 3 - SOLID PANEL STRUCTURES: DURAKING AND TRIPLE SIX PAN MAXIMUM SPANS AND MINIMUM FASTENERS S4.1 -SOLID PANEL STRUCTURES: BEAM PROFILES S4.2-SOLID PANEL STRUCTURES: BEAM PROFILES S4.3 - SOLID PANEL STRUCTURES: COLUMN PROFILES S4.4-SOLID PANEL STRUCTURES: MEMBERS PROFILES S4.5-SOLID PANEL STRUCTURES: CONNECTORS S5.1 -SOLID PANEL STRUCTURES: SPLICE DETAILS S6.1 - SOLID PANEL STRUCTURES: ATTACHMENT TO EXISTING BUILDING S62 - SOLID PANEL STRUCTURES: CONNECTION DETAILS S6.3 - SOLID PANEL STRUCTURES: CONNECTION DETAILS S7.1 -SOLID PANEL STRUCTURES: FOUNDATION DETAILS S7.2 - SOLID PANE L STRUCTURES: FOUNDATION DETAILS SBxxx- SOLID PANEL STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LUSL, 1x0 MPH G9.1 -ADDITIONAL STATE LICENSURE STAMPS SOLID PANEL STRUCTURE TYPE A: ATTACHED SINGLE SPAN WITH OPTIONAL CANTILEVER 2485 RAILROAD ST, CORONA, CA 92680 951.736.4500 �IpF�551gy�( �Q��Q' Lif S 50 5 R� T,4 �'[ tiy1P TF OF CAL IFS DATE SIGNED: July 06, 2018 �i TCL. 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 �APnnAA Irin WVV ES TM REVISIONS MARK DATE DESCRIPTION 4 STE . JOB # 17-1071 DATE 04125/18 DRAWN BY RER CHECKED MDS IAPMO 195 V 3.0 SOLID PANEL STRUCTURES: TYPE A S1.1 (E) BUILDING 11f11.t!llf�f�u���»���1»rirtL�lf(L!.(.(Lliiiii»i�i�. I I L O B NO COL,' TYP COVER TECj10N ' D IjLDc $EE NOTE SEE NOTE.4 z• I I I i I I I I m z Lu it w I V) I I I ' � I SOLID COVER CONNECTION m TO BEAM SEE NOTE 2' O m Z I I w H I I I I ' BEAM CLEAR SPAN L BEAM CLEAR SPAN LENGTH 'L' SEE NOTE 1 G PLAN VIEW NOTES: I. RATIQ A LENGTH OF STRUCTURE 'L' SHALL NOT BE LESS THAN ITS PROJECTION 'P'. SEE DESIGN ASSUMPTION NOTE 10 FOR PATIO COVERS CONSISTING OF SOLID COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAM'S ADJACENT CLEAR SPAN. EXCEPTION= NO OVERHANG ALLOWED AT I BEAMS CONNECTED TO SIDE OF COL D. SOLID COVER OVERHANG 'OH' SHALL NOT EXCEED 25% OF BOTH DECK & IRP SOLID COVER'S ADJACENT CLEAR SPAN, (OR 24" MAX. AT IRP, WHICHEVER IS LESS). E. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: •TRIB (Bext)= X ADJACENT DECK CLEAR SPAN @ RIGHT + DECK OH @ LEFT • TRIB (Sint)= Yz ADJACENT DECK CLEAR SPAN @ RIGHT + h ADJACENT DECK CLEAR SPAN @ LEFT TRIG (BLDG)=Y2 ADJACENT DECK CLEAR SPAN W!Il1xI8I� i A SEE SHEET S3.1A AND S3.3 FOR DECK PROFILES AND MAXIMUM SPANS. B. SEE SHEET S3.2 FOR DURAPANEL INSULATED STRUCTURAL SANDWICH PANELS MAXIMUM SPANS. C. SEE SHEET S2.1 FOR REDUCTION OF SOLID COVER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET S3.2 FOR CONNECTION OF SOLD COVERS TO SUPPORTING BEAMS. E. SEE SHEETS S3.2 & S6.1 FOR CONNECTION OF SOLID COVERS TO (E) BUILDING. F. MINIMUM SLOPE OF SOLID DECK COVERS TO BE PER S3.2. G. MINIMUM SLOPE OF DURAPANELS TO BE PER SHEET S3.2. SOLD ROOF PANEL SEE NOTE 2-- CONCRETE FTG, SEE NOTE 5, TYP n ISOMETRIC VIEW v 3/3f=l'-0" Nw.AMM A. SEE SHEETS S4.1 & S4.2 FOR BEAM PROFILES. B. SEE SHEET S4.2 FOR FAN BEAM WHERE OCCURS. C. SEE SHEETS S7.1 AND S8.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPANS. D. SEE SHEET S2.1 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. E. SEE SHEETS S6,x FOR BEAM CONNECTIONS & DETAILS. F. SEE SHEETS S5.1 AND S6.3 FOR BEAM SPLICE DETAIL WHERE REQUIRED. BEAM SIMPLE SPLICE, WHEN NEEDED, SHALL BE LOCATED IMMEDIATELY ABOVE AN INTERIOR COLUMN. NO BEAM SPLICE SHALL BE PERMITTED BETWEEN COLUMNS OR ON TOP OF AN EXTERIOR COLUMN. .. cn::lrANs A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBERS OF POSTS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET S4.3 FOR COLUMN PROFILES. C. SEE SHEETS S7.1 AND S8.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS S6.x AND S7.x FOR POSTS CONNECTIONS & DETAILS. I•fflYl11]2HlrLt�J.E9 A SEE SHEET S7.1 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEET SB.xx.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED. C. SEE S7.1 FOR ALTERNATE FOOTING SIZES. D. SEE 8/S7.1 FOR ATTACHED PATIO COVER SUPPORTED ON SLAB ON GRADE. TABLE 1 MINIMUM NUMBER OF POSTS REQUIRING ATTACHMENT PER 31S6.3 OR 3/1-6.3 WITH 2 x 6.5 x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) TRIG WIDTH WNDS PEEDAND 1105 110C I 120E 120C 13DE 130C 5 2 2 2 3 3 3 6 2 -3 3 3 3 4 7' 2 3 3 4 3 4 B' 3 3 3 4 4 5 9 3 4 4 4 4 5 10' 3 4 4 5 5 6 11' 4 4 4 5 5 6 17 4 5 5 6 5 7 WITH 2 x 5.5 x 0,042 SIDE PLATES (SIDE PLATE TYPE SPA) TRIG WIND_SPCEDANIJ WIDTH 11D6 110C 120B 1200 13DB 13DC 5' 2 2 2 2 2 3 6' 2 2 2 3 3 7 2 3 3 3 3 4 H 2 3 3 4 3 4 J 3 1 3 3 4 4 5 1U 3 a a 4 4 5 11' 3 4 4 5 5 6 1Y 3 4 4 5 5 5 NOTES: 1. NUMBER OF POSTS SHOWN IN THIS TABLE IS A MINIMUM. ADD POSTS AS REQUIRED TO ENSURE THATTHE "MAX POST SPACING (SPAN)" SHOWN ON SHEETS S&xx.x OR L&xx.x IS NOT EXCEEDED. 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL 3186.3 OR 3/L6.3. 3. THIS TABLE DOES NOT APPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHETICAL PURPOSES AND THE BEAM IS CONNECTED TO THE COLUMN DIRECTLY OR WITH A BRACKET PER S6.3OR L6.3. (�� TABLE i -MINIMUM NUMBER OF COL, REQUIRING TOP ATTACHMENT PER 3/8&r3 OR 3/L63 Sff.gT INDEX -SOLD PANEL STRUCTURES: TYPE B GDA -TITLE SHEET, DESIGN LOADS, GENERAL NOTES S 1.2 - SOLID PANEL STRUCTURES: TYPE B 82.1 -SOLID PANEL STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT AND SLIDING S3.1A-SOLID PANEL STRUCTURES: ATTACHED COVERS MAXIMUM SPANS AND MINIMUM FASTENERS S3.2-SOLID PANEL STRUCTURES: CROSS SECTIONS S3.3 - SOLID PANEL STRUCTURES: DURAKING AND TRIPLE SD( PAN MAXIMUM SPANS AND MINIMUM FASTENERS S41 -SOLID PANEL STRUCTURES: BEAM PROFILES S42-SOLID PANEL STRUCTURES: BEAM PROFILES S4.3-SOLID PANEL STRUCTURES: COLUMN PROFILES S4.4-SOLID PANEL STRUCTURES: MEMBERS PROFLES S4.5-SOLID PANEL STRUCTURES: CONNECTORS S5.1 - SOLID PANEL STRUCTURES: SPLICE DETAILS S6.1 - SOLID PANEL STRUCTURES: ATTACHMENTTO EXISTING BUILDING S6.2 - SOLID PANEL STRUCTURES: CONNECTION DETAILS S6.3 - SOLID PANEL STRUCTURES: CONNECTION DETAILS S7.1 -SOLID PANEL STRUCTURES: FOUNDATION DETAILS 57.2 -SOLID PANEL STRUCTURES: FOUNDATION DETAILS SB`xx- SOLID PANEL 67RUC7URES: BEAM SPANS AND FOUNDATION SIZES xx PSF LL/SL,1x0 MPH GDA -ADDITIONAL STATE LICENSURE STAMPS SOLID PANEL STRUCTURE TYPE B: ATTACHED MULTI -SPAN WITH OPTIONAL CANTILEVER m I SOLID COVER CONNECTION m W TO BLDG SEE NOTE 2 w ~ W II N < h J U Y U im Z w w a Z � F- W m COL, TYP m a SEE NOTE 4 CL BEAM CLEAR SPAN LENGTH 'L' SEE NOTE 1 C PLAN VIEW NOTES: 1. PATIO COVER DIMENSIONS A. LENGTH OF STRUCTURE 'L' SHALL NOT BE LESS THAN ITS PROJECTION 'P'. SEE DESIGN ASSUMPTION NOTE 10 FOR PATIO COVERS CONSISTING OF SOLID COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAM'S ADJACENT CLEAR SPAN. EXCEPTION= NO OVERHANG ALLOWED AT I BEAMS CONNECTED TO SIDE OF COL D. SOLID COVER OVERHANG 'OH' SHALL NOT EXCEED 25% OF BOTH DECK & IRP SOLID COVER'S ADJACENT CLEAR SPAN, (OR 24" MAX. AT IRP, WHICHEVER IS LESS). E. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: -TRIG (Bext)= )j ADJACENT DECK CLEAR SPAN @ RIGHT + DECK OH @ LEFT 2. SOLID COVERS A. SEE SHEET S3.1A AND S3.3 FOR DECK PROFILES AND MAXIMUM SPANS. B. SEE SHEET S3.2 FOR DURAPANEL INSULATED STRUCTURAL SANDWICH PANELS MAXIMUM SPANS. C. SEE SHEET S2.1 FOR REDUCTION OF SOLID COVER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET S3.2 FOR CONNECTION OF SOLID COVERS TO SUPPORTING BEAMS. E. SEE SHEETS S3.2 & S6.1 FOR CONNECTION OF SOLID COVERS TO (E) BUILDING. F. MINIMUM SLOPE OF SOLID DECK COVERS TO BE PER SHEET S3.2. G. MINIMUM SLOPE OF DURAPANELS TO BE PER SHEET S3.2. 1169 t OF SEE NOTE 5, TYP B ISOMETRIC VIEW ranr.�rrrrxnm 3. BEAMS A. SEE SHEETS S4.1 & S4.2 FOR BEAM PROFILES. B. SEE SHEET S4.2 FOR FAN BEAM WHERE OCCURS. C. SEE SHEETS S7.1 AND SB.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPANS. D. SEE SHEET 52.1 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. E. SEE SHEETS S6.x FOR BEAM CONNECTIONS & DETAILS. F. SEE SHEETS S5.1 AND S6.3 FOR BEAM SPLICE DETAIL WHERE REQUIRED. BEAM SIMPLE SPLICE, WHEN NEEDED, SHALL BE LOCATED IMMEDIATELY ABOVE AN INTERIOR COLUMN. NO BEAM SPLICE SHALL BE PERMITTED BETWEEN COLUMNS OR ON TOP OF AN EXTERIOR COLUMN. 4. COLUMNS A. SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBERS OF POSTS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET S4.3 FOR COLUMN PROFILES. C. SEE SHEETS S7.1 AND SB.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS S6.x AND S7.x FOR POSTS CONNECTIONS & DETAILS. 5. FOUNDATIONS A SEE SHEET S7.1 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEET SB.xx.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED. C. SEE S7.1 FOR ALTERNATE FOOTING SIZES. TABLE 1 MINIMUM NUMBER OF POSTS REQUIRING ATTACHMENT PER 3/S6.3 OR31L6.3 WITH 2 x 6.5 x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) WIDTH TRIGE33 EDAN 5 US E 1209 1200 130E 130C 5' 2 3 3 3 & 3 3 3 4 T 3 4 3 4 8 3 4 4 5 9' 4 4 4 5 10 4 5 571' 4 5617 5 6 5 T WITH 2 x 6.5 x 0.042 SIDE PLATES (SIDE PLATE TYPE SP4) TRIB WIND SPEED ANDS U E WIDTH 110E i1DC 12DB 120C I 13UB I= 6 2 2 2 2 2 3 6' 2 2 2 3 3 3 T 2 3 3 3 3 4 B' 2 3 3 4 3 4 9' 3 3 3 4 4 5 IV 3 4 4 4 4 5 1'r 3 4 4 5 5 5 17 3 4 4 5 5 5 NOTES: 1. NUMBER OF POSTS SHOWN IN THIS TABLE IS A MINIMUM. ADD POSTS AS REQUIRED TO ENSURE THAT THE "MAX POST SPACING (SPAN)' SHOWN ON SHEETS S&xx.x OR L&xx.x IS NOT EXCEEDED. 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL 31S6.3 OR 31L6.3. 3, THIS TABLE DOES NOTAPPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHETICAL PURPOSES AND THE BEAM IS CONNECTED TO THE COLUMN DIRECTLY OR WITH A BRACKET PER S6.3 OR L6.3. A TABLE 1 - MINIMUM NUMBER OF COL REQUIRING TOP ATTACHMENT PER 3/56,3 OR 3/L63 SHEET INDEX -SOLID PANEL STRUCTURES: TYP E C PANEL STRUCTURE TYPE C: FREESTANDING SINGLE SPAN WITH OPTIONAL GO.1 -TITLE SHEET, DESIGN LOADS, GENERAL NOTES S1.3 - SOLID PANEL STRUCTURES: TYPE C S2.1 - SOLID PANEL STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT AND SLIDING S3.1 F - SOLID PANEL STRUCTURES: FREESTANDING COVERS MAXIMUM $PANS AND MINIMUM FASTENERS S3.2-SOLID PANEL STRUCTURES: CROSS SECTIONS S3.3 -SOLID PANEL STRUCTURES: DURAKING AND TRIPLE SIXPAN MAXIMUM SPANS AND MINIMUM FASTENERS S4.1 - SOLID PANEL STRUCTURES: BEAM PROFILES S42 - SOLID PANEL STRUCTURES: BEAM PROFLES S4.3 - SOLID PANEL STRUCTURES: COLUMN PROFILES S4.4 - SOLID PANEL STRUCTURES: MEMBERS PROFILES S4.5 - SOLID PANEL STRUCTURES: CONNECTORS 85.1 -SOLID PANEL STRUCTURES: SPLICE DETAILS S6.1 - SOLID PANEL STRUCTURES: ATTACHMENT TO EXISTING BUILDING S62 - SOLID PANEL STRUCTURES: CONNECTION DETAILS S6.3 - SOLID PANEL STRUCTURES: CONNECTION DETAILS S7.1 - SOLID PANEL STRUCTURES: FOUNDATION DETAILS S7.2 - SOLID PANEL STRUCTURES: FOUNDATION DETAILS SB".x-SOLID PANEL STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LLISL, 1x0 MPH G9.1-ADDMONALSTATE LICENSURE STAMPS -D IW La E I Z - I I I - LiLd SOUD COVER CONNECTION i N TO BLDG SEE NOTE 2 COL, TYP, ( I SEE NOTE 4 u � 0 z w z z a • I I I I I I I I w a Ld OH BEAM CLEAR SPAN BEAM CLEAR SPAN+ TE 1 LENGTH 'L' SEE NOTE 1 BEAM OH � PLAN VIEW • NOTES: 1.O[MENSIONS A. LENGTH OF STRUCTURE 'L' SHALL NOT BE LESS THAN ITS PROJECTION 'P'. SEE DESIGN ASSUMPTION NOTE 10 FOR PATIO COVERS CONSISTING OF SOLID COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAM'S ADJACENT CLEAR SPAN. EXCEPTION= NO OVERHANG ALLOWED AT I BEAMS CONNECTED TO SIDE OF COL D. SOLID COVER OVERHANG 'OH' SHALL NOT EXCEED 25% OF BOTH DECK & IRP SOLID COVER'S ADJACENT CLEAR SPAN, (OR 24" MAX. AT IRP, WHICHEVER IS LESS). E. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: • TRIB (Beat)= Yz ADJACENT DECK CLEAR SPAN @ RIGHT + DECK OH @ LEFT • TRIB (Sint)= Yx ADJACENT DECK CLEAR SPAN @ RIGHT + Y2 ADJACENT DECK CLEAR SPAN @ LEFT A. SEE SHEET S3.1A AND S3.3 FOR DECK PROFILES AND MAXIMUM SPANS. B. SEE SHEET S3.2 FOR DURAPANEL INSULATED STRUCTURAL SANDWICH PANELS MAXIMUM SPANS. C. SEE SHEET S2.1 FOR REDUCTION OF SOLID COVER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET S3.2 FOR CONNECTION OF SOLID COVERS TO SUPPORTING BEAMS. E. SEE SHEETS S3.2 & S6.1 FOR CONNECTION OF SOLID COVERS TO (E) BUILDING. F. MINIMUM SLOPE OF SOLID DECK COVERS TO BE PER SHEET S3.2. G. MINIMUM SLOPE OF DURAPANELS TO BE PER SHEET S3.2. SOLID ROOF PANEL SEE NOTE 2 EXT. BEAM SEE Z SEE NOTE 3 9 Opp INT. BEAM SEE NOTE 3 4-CONCRETE SLAB, CONCRETE FTG, SEE NOTE 5 SEE NOTE 5, TYP B ISOMETRIC VIEW 3/32"=1'-O" 3. BEAMS A. SEE SHEETS S4.1 & S4.2 FOR BEAM PROFILES. B. SEE SHEET S4.2 FOR FAN BEAM WHERE OCCURS. C. SEE SHEETS STI AND SB.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPANS. D. SEE SHEET S2.1 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. E. SEE SHEETS S6.x FOR BEAM CONNECTIONS & DETAILS. F. SEE SHEETS S5.1 AND S6.3 FOR BEAM SPLICE DETAIL WHERE REQUIRED. BEAM SIMPLE SPLICE, WHEN NEEDED, SHALL BE LOCATED IMMEDIATELY ABOVE AN INTERIOR COLUMN. NO BEAM SPLICE SHALL BE PERMITTED BETWEEN COLUMNS OR ON TOP OF AN EXTERIOR COLUMN. 4. COLUMNS A. SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBERS OF POSTS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET S4.3 FOR COLUMN PROFILES. C. SEE SHEETS S7.1 AND SB.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS S6.x AND S7.x FOR POSTS CONNECTIONS & DETAILS. 5. MNDATION A. SEE SHEET S7.1 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEET SB.xx.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED. C. SEE S7.1 FOR ALTERNATE FOOTING SIZES. TABLE 1 MINIMUM NUMBER OF POSTS REQUIRING ATTACHMENT PER 3/S6.3 OR 316.3 WITH 2 x 6.5 x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) TRIB WIDTH WIND SPE ED A H 1108 t 110C I 120B 1= I 1306 131TC 5' 2 2 2 3 3 3 B 2 3 3 3 3 4 r 2 3 3 4 3 4 IT 3 3 3 4 4 5 Er 3 4 4 4 4 5 10 3 4 4 5 5 s 11• 4 4 4 5 5 6 12 4 5 5 6 5 7 WTT14 2 x 6.5 x 0.00 SIDE PLATES (SIDE PLATE TYPE S P4) TRIB WINDSPEEDA p SU E WIDTH 1108 110C 1208 12DC 130E 130C 5' 2 2 2 2 2 3 6' 2 2 2 3 3 T 2 3 3 3 3 4 e 2 3 3 4 3 4 5 3 3 3 4 4 5 10 3 4 4 4 4 5 11' 3 4 4 5 5 8 17 3 4 4 5 5 3 NOTES: 1. NUMBER OF POSTS SHOWN IN THIS TABLE IS A MINIMUM. ADD POSTS AS REQUIRED TO ENSURE THAT THE "MAX POSTS PACING (SPAN)' SHOWN ON SHEETS SB.xx.x OR L&xx.x IS NOT E)CEEDED. 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL 3/S6.3 OR 3/L6.3. 3. THIS TABLE DOES NOT APPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHETICAL PURPOSES ANDTHE BEAM IS CONNECTED TO THE COLUMN DIRECTLY OR WITH A BRACKET PER S6.3 OR L6.3. (A) TABLE 1 - MINiMUM NUMBER OF COL REOUIRING TOP ATTACHMENT PER 3/883 OR 3/L63 SHEET INDEX -S_QLJD PANEL STRUCTUR S E D GDA -TITLE SHEET, DESIGN LOADS, GENERAL NOTES SIA -SOLID PANEL STRUCTURES: TYPE D S2.1 -SOLID PANEL STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT AND SLIDING S3.1 F - SOLID PANEL STRUCTURES: FREESTANDING COVERS MAXIMUM SPANS AND MINIMUM FASTENERS S3.2-SOLID PANEL STRUCTURES: CROSS SECTIONS S3.3 -SOLID PANEL STRUCTURES: D URAKING AND TRIPLE SIX PAN MAXIMUM SPANS AND MINIMUM FASTENERS S4.1 -SOLID PANEL STRUCTURES: BEAM PROFILES S4.2 -SOLID PANEL STRUCTURES: BEAM PROFILES S4.3-SOLID PANEL STRUCTURES: COLUMN PROFILES S4.4-SOLID PANEL STRUCTURES: MEMBERS PROFILES S4.5 - SOLID PANEL STRUCTURES: CONNECTORS S5.1 -SOLID PANEL STRUCTURES: SPLICE DETAILS S6.1 - SOLID PANEL STRUCTURES: ATTACHMENT TO EXISTING BUILDING S6.2-SOLID PANEL STRUCTURES: CONNECTION DETAILS S6.3 - SOLID PANEL STRUCTURES: CONNECTION DETAILS S7.1 -SOLID PANEL STRUCTURES: FOUNDATION DETAILS S7.2 -SOLID PANEL STRUCTURES: FOUNDATION DETAILS SBxax- SOLID PANEL STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LUSL,1xO MPH G9.1 -ADDITIONAL STATE LICENSURE STAMPS SOLID PANEL STRUCTURE TYPE D: FREESTANDING MULTI -SPAN WITH OPTIONAL CANTILEVER 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 ESSIL ' Y'. �tC7 "}r� S 5885 OF CA0� DATE SIGNED: July 06, 2018 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 IA NC)TM REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # 17-1071 DATE 04125/18 DRAWN BY RER CHECKED MDS IAPMO 195 V 3.0 SOLID PANEL STRUCTURES: TYPE D S1.4 ALUM. ALLOY 3004-H35 ALUM. ALLOY 3004•-H35 0.80" TOP FLUTE ATTACHMENT SUM' ALLOY 300fM36 0.40" ATTACHMENT `vo `03 PER NOTES 2, TYP. D 72' TOP FLUTE ATTACHMENT PER NOTES 2, TYP. 0.35" D.40" 0.25" S 2, TYP. c c BOTTOM FLUTE ATTACHMENT I n 1' a BOTTOM FLUTE ATTACHMENT 0 40" niffl PER NOTES 1 THRU 5, TYP. I� I D.40" c PER NOTES 1 THRU 5, TYP. 0.88" o HIMENTE 0.45" 0.35" FER THRU 5, ` n o ao D T o ri 0.45' "� o D.4O" N0.65"0.35" D.65' 0.. E0. 0.375" o 2.00' 1.29" 1.29" 2.02" 0.43" 3.00" 4.50" 4.50" 4.50" 4.50" 3.00" 0.75" 6.00" 0.75" 1'-0.00' 24.DOD" OR 8.OD" TRI-V PAN 8' OR 8' x 2-1/Z FLAT PAN 1 12' x 3112' W PAN TABLE 1A-ATTACHED COVERS MAXIMUM SPAN FOR 24" TRI-V PAN UJGSL TON) WIND SP RAND MOSURE 110B 110C 120B 120C 130B 130C 10 0.018 1 10'-3" 1U-3" 193' 1a-T 10'3" 1V-3" 0.024 72 3" 1Z-3" 1Z3" 12.3' 12'3" 12'-3" 0.032 14'3 14'-3" 14'-3' 14-3" 14'-3" 14'-3" D.p1B 6�^ a'3" B-4" B7a' 8"� B'a^ 20 0.024 10'-V ]a-1" 10'-1" 10-1" 10'-1' 10, 1" 0,032 12'-1" 17-1" 1r-11 tr-1" 121-1" 12=1' 0.018 T-3" T-3" 7-7 T3" 7'-3" T3" 25 0.024 6-9 8'-9' 8-T v-9" 1 6'-T a.4- 0.032 9 8" 9 8" 9-B" 9`-8" I 9'-B" 9'-0" 30 0.015 6-7" 6-7" 6 T 6'--r 6'-7" 6' 0.024 B-7 V3" 6-3" 84' 8'-3"8'0,032 fl 9-1" 9'-1" 9-1• 9'-1- 9'_1" 9 TABLE 2 - MULTI SPAN REDUCTION FACTORS ROOF PANEL TYPE ROOF LIVE l GROUND SNOW LOAD (psf) 10 20 25 30 40 50 12 x 3.1/2 x 0.02 - - 0.88 0.83 0.75 0.B0 :24 x 2-12 x 0-018 0.85 0.80 0.65 0.65 - - 2 4 x 2-V2 x 0.024 0.90 0.66 6.70 0-65 - - 24 x 2-1l2 x 0,032 0.90 0.88 - - - - OTHERS - - - - - TABLE 18 -ATTACHED COVERS MAXIMUM SPAN FOR x 2-1/2 FLAT PAN LVGSL TON) WIND SPEED AND XPOSURE 110 B 110 C 1 120 B 120 C 130 B 130 C 0.020 14-7' 14-T 14-T 14.7' 14'7' 14'-7 0.024 15-10" 10 0.D32 I 18'-0" LLB'-Ir I 18'-0" 18'-¢ 16-0- 1U-0" D.040 19'-4" 19 4" 194" 19 4" 79'4" 194" 0.02D 1z-1" 1z-1' 12-1- 1r-1" 12'-1" 171' 0.024 13'-3" 13-r 113'3" 13-3" 13'3" 13-Y 2D 0.032 15'.T 16-T -6' 1 S-6" IN-W 1 S-T 0.040 16-B" 16-8''�' gi 16-T 164' 164r 0.020 10=4" 1a-4" 4' 1 a-4' 10'-4" 10'-" 25 0.024 1 11-1" 11'-1' 1V-1' i1'-1' 11=1' 11'-1' 0.03212-1' 12-1" 1z-1' 12-1" L^-'-1' 1Z-1" 0.D40 13'-1' 13-1" 13-1` 13'-1" 13'-1" 13-1" omo 9-3" 9'-9" 9'-9" 91-3" 1 9-9" 9'-9" 30 0.024 10'-4• 1a4" 1174" 10f-47 10'-4" 1a-a 0.032 1 T J1' 11'-4" 11'4' 1 T-V 11'-4" 1 T41" b.040 7 3' 12-Y 1z-3" 1Z-3• 1Z-3" 12-3" 0.030 !m- 9'-0" 9-0' 9'-0" 9-0" 9'-0" 40 0.024 9$" 9'-V 9-T 9-V 9'3" 1 a-0' 1 a-4" 19-4- 1 a-4" 19-4- 1 a-" 11'-2" 1 T-T 1 T-2" 1 T-2" 11'-2- 1 T-2" rO.O4O 8'-7 B'3" IT-7 8'3" 8'-7 83" 8'-9' B' 9" B-9 8'-98'-9B 9'-8" 9'-8"9'3' 9 8' 9 10-4- 1a-V 10'4" 1a-V 10'4" 1a 4" TABLE 1C- ATTACH ED COVERS MAXIMUM SPAN FOR 8 x 2-1/2 FLAT PAN LVGSL TOM WIND SPEED AND EXPOSURE 110B 110C 1 1208 1 120C 1308 13DC 0,020 121-6" 1r1" 1r3 0.024 13`-7 13'•7- 13'-7" 10 0.032 15'-7" 16-7" 1 15'-7' 0_o4o 1T-7- 177" 1i 7" 17-7" 1T-T 17-T 0.020 10'-2" 10'-2" 10'-2" 1 a-2' 110'-2" 1 U-7 0,024 1 1T-41" 11'-V 114" 11'-' 11'-4" 11'-4" 2D p.032 13'-0° 13'-0° 1 X-0" 13-0" 13'-0, 13,4r 0.040 1 14-S" 14'-6' 14-6' 14-V 14'-6" 14'-0" 0.020 9'-9" 9'-9" 9'-9" 9=9" 5-9" T-9" 25 0.0^_4 10' 4" 1a� Tam' 1a�` I 704' 10-4 0.032 11'-4' 1T'-0" 114' 1 T-V 11'Le 11'4- 0.040 12-3" 12'3" 1Z-3" 12-3" 1Z-7 12-7 0.020 V-3" T-3" 9'3" 9'-3" ( 9'3- 9-3" O.OZ4 8'-9" 9'-9". 9' 9" 9'-9^ I 9-9' 9'A" 0.032 10'-9" 10'-9" 10, 1a8" 10'-9" to-9 0.040 1 V-7' 11' 7" 1 V-7" 11' 7" 11' 7" 1 T-7" 0.020 8'7° 8'4" V-4- 8'4" 813" 13'4° AO 0.024 9'-0" 9'-0" 9'-0" 9'-0" 5-0" 9'-0' 0.032 T-9" 9._9" 91-F g_y" g-9- 9,_9" a m 10'-7" 10' 7" 10'-7" 1a-7" 10, r 1 a-7" 0.020 T-5" T-5" TS" 7'-5" 7-5' T-6- 0.024 V-3" 8=3" 8'3" a'-3" 83" V3" so 0.032 9'-1" 9, 9.1' 0.040 9-9" 1 9, 9" 9'A" 9'-9" I 5A° 9'-9" TABLE 3--ATTACHED COVERS - FASTENERSCHEDUL.E- SEE TABLE 4 FOR LEGEND NUMBER FROM TABLE 4 REPRESENTS THE NUMBER OF #10 TEKS ORSMS TO SUPPORTING BEAMS AND WALL HANGERS IN EVERY DECK SECTION 5-112" ROLL FORMED AND (2) 2 x 6-1/2 BEAMS (B1, B9, BTO) WALL HANGERS AND 3 x 8 ROLL FORMED (B11, B12) EXTRUDED AND 3x W/ STEEL INSERT BEAMS (B2, B3 B4, B5, 136, B7, B8, B13, B14, B15, B16) (SCREW INSTALLED IN STEEL INSERT) TRiB WIDTH WIND SPEED AND E PO:SURE 7R1B WIDTH WIND SPEED AND EXPOSURE TRIB I WIDTH WIND SPEED AND EXPOSURE 110 B 110 C 120 B 120 C 130 E 130 C 110 E 110 C 120 E 120 C 13D B i 33 C 110 B 110 C 120 E 120 C 1 130 8 130 C S A A A A A B 5 A A A A A A 1 6 A A A A I A A .6 A A A B B B G A A A A A B 6' A A A A A A T A A A B B B T A A A 8 B B 7' A A A A A A 8' A B B B B B 8' A A B B B B B' A A A A A A 9 B B B B B B 9' A B B B B B 9' A A A A A A 10' B B B B B C 10' A B B B B B 1 a A A A A A A 11' B B B B B I C 11' A A A A A B tr B B C G C C 1r B B B B B C 1z I A A 1 A A A I B TABLE 1 D - ATTACHED COVERS MAXIMUM SPAN FOR 12 x 3-12 W PANEL LVGSL TQN) WIN SPEED AND E.V E 110E 11DC 120B 1200 130E 130C 0.=0 13-9' i3'•9" 13-T i3-9" 13'-9' 13'•9" 0.024 1S-E 15'3" 16-7 153" 15=3' 153" 10 0, D32 177 IT-7- 1T 7' IT-7- 1 T-7" 17' 7" D. D40 19-T 19' 7" 19-T 19' 7" 19-7' 1Y7" 01020 11'-3" 11'3" 71'-3" 1113" 11'-3' 11'3" 0.024 12� 1r-0 12-V 12'S 17-6" 12'3" 20 0.032 144$ 14'$" 194r 14'" 14'-B" V-S" 0.D40 16-3' 16"3' 1E X 15-3" 16'3- 16'3" 25 0,024 1240" 12"4" 12-0' 1r-0" 1Z-0" 1Z-0" 0.032 13-7 13'-2' 13-2' 13' 7 13-2" 13'-Z" a D40 W-7 1*2" 14-2" 14-2' 14'-2" 14'-2" 30 0.020 1fY-£ V-e 1 117-6' 10'-" 10'T 10'-6" 0,024 IT-3- 11'3" 11'-3" 1 11'-3" 1 V-3" 11. 0,032 17•E IK--i: 12-T 1T43" 1r-5- 1ZF 0.04o I7._C 13'_" 13-4" 13'4' 13'4" 13' 4" 0.020 9-1" 9-1' 4.1" 9'-1" 9'-1' 9'-1" 40 0.024 W-3" 193• 1U-W 173" 10'4' 17-S' 0.032 1T-C 114' 11'-4" 11'-4" 11'-4' 11'-4" 0.D40 12-7 12 2" 12-2" 12'-7 17-2" 121-2" 0.020 8'-2' 8'-Z' 81-7 8'-21 61-2" 812, 0.024 9'2" 9-2" 9=2" 9-2' 91•2" 5--2 50 Q D31 11Y 7" 10' 7" 1 7_7 7D' -r 10'-7" 10'-7" 0,D40 11'-3• 1P-3" 11'-3" 11'3 11'-3" 1113" NOTES FOR DECK AITACHMENTTO SUPPORTING BEAMS ANO WALL HANGERS: i - MINIMUM ATTACHNIENT OF PANS TO 8EAdS (EXCEPT BEAM PROFILE Bi) SHALL BE MADE WITH (1) -.10 SMS OR TEK SCREW AT EA CH BOTTOM FLUTE. 2 - MINIMUM ATTACHMENT OF PANS TO WALL HANGERS AND BEAM PROFILE B1 SHALL BE MADE WITH (1) 010 SM5 ORYEK SCREW AT EACH BOTTOM FLUTE. AND (1)910 SMS OR TEK 5CREW AT EACH TOP FLUTE. 3 - IN ADC41ION TO THE RE✓?UIREMENTS FROM NOTES ABOVE. THE MINIMUM ATTACHMENT SHALL COMPLY WITH TABLES 3 AND 4. 4 - TABLES 3 AND 4 AND NOTE 3 ABOV E DO NOT APPLY TO GUTTERS OR C-SHAPED DECK CLOSURE PLA TES THAT ARE N0TUSEDAS BEAMS (NON-STRUCTURAL MEMBERS NOT CONNECTED TO COLUMNS AND I NS TA LLE D AT THE END OF AN OVERHANG OR PARALLEL TO THE DIRECT ON OF THE DECK) 5 - WHEN ATTACHING TO BEAMS 89, B10, 815 OR 515 (DOUBLE MEMBERS), ATTACHM.ENTCAN BE MA DE70 EITHER 1"1EMBER OF THE BEAM, BUT SHALL BE EVENLY SPLIT BETWEEN THE 2 MEMBERS. TABLE 4 -ATTACHED COVERS LEGEND FOR TABLE 3 DECKSEC710M A B C D E WIDTH 6" FLAT PAN 6" 1 1 1 1 2 8" FLAT PAN B" 1 1 1 2 2 12" TRI V PAN 12' 1 2 3 3 4 24" W PAN 24" 1 2 3 4 5 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 FEm i S 5885 T ,e 9rF OF CAL�ty DATE SIGNED: July 06, 2018 vNwc 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 SAP OTM E REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # 17-1071 DATE 04125(1B DRAWN BY RER CHECKED MDS D 195 SOLID PANEL STRUCTURES: FREESTANDING COVERS MAXIMUM SPANS AND MINIMUM FASTENERS S 3.1 F TABLE 1 - SOLID PANEL STRUCTURES FASTENER SPACING SCHEDULE SEE NOTES 1 AND 2 IRP ROOF PANEL WIND SPEED AND EXPOSURE 110 (MPH) B C 120 (MPH) B C 130 (MPH) B C 3" - 0.024" A A A A A A 4.25" - 0.024" A A A A A A 3"- 0.030" A A A A A B 4.25" - 0.030" A B B B B B NOTE: 1) A 6" O.C. TOP CONNECTION TO BEAMS 12" O.C. T&B CONNECTION TO LEDGER ROLL FORMED OR INSULATED ROOF PANEL (E) BLDG. WHERE OCCURS INTERLOCKING SEAMS, TYP. I I I I 2A ! 1 ? I @IRP I I I 28 I I I j i @ RFP • I f 2) B. 4 D.C. TOP CONNECTION TO BEAMS B" O.C. T&B CONNECTION TO LEDGER 01A@IRP (103 @RFP COLUMN SEE SHEET S4.3 FASTENER SPACING SCHEDULE PLAN VIEW BEAM, SEE SHEETS S4.1 & S4.2 +7 A V A . N.T.S. N.T.S. OPTIONAL DECORATIVE FASCIA (WOOD, ALUM. OR HARDBOARD) #10 S.M.S. TOP & BOTTOM, EXTRUDED IR HANGER PER SPACING PER 3/S3.2 #1 D S.M.S., EXTRUDED DRIP EDGE 9/54.4 SLOPE SPACING, PER 3/53.2 "IR3" GUTTER SEE NOTE 2 ATTACHMENT 14 SMS @ 32" O.C. #B x J¢" TOP &BOTTOM TO BUILDING 4 MIN. PER EACH JOINT @ 12" O.C. WHERE OCCURS PER 49/S6.2 / x lf" @ O.C. OPTIONAL TO 3" OR 4Y;' OR 6° TOP &BOTTOM NON-STRUCTURAL DURAPANEL, SEE NOTE 1 BEAM PER S4.1 & S4.2 FASCIA (3 x 8 BEAM SHOWN) OPTIONAL MAX SPAN PER APPROVAL MAX OVT3niANG PER NOTE RAIN GUTTER ALUMINUM SKINS IRP REPORT - SEE NOTE T I ON S1.x TOP & BOTTOM 0.024" NOTES: 1. THE IRP ROOF PANELS USED WITH THE PATIO COVER STRUCTURES RECOGNIZED IN THIS EVALUATION REPORT MUST BE A DURALUM PRODUCT PER IAPMO-ER-0505, CALIFORNIA FBH CA-LRP-2410 OR CA-LRP-3220. 2. THE SLOPE OF THE IRP ROOF PANELS SHALL BE PER THE IAPMO OR FBH REPORTS LISTED ABOVE. RECOMMENDED MINIMUM SLOPE IS PER FOOT AT COVERS DESIGNED FOR LIVE LOADS, AND Yip PER FOOT AT COVERS DESIGNED FOR SNOW LOADS, INSULATED ROOF PANEL (IRP) .. 1 INSULATED ROOF PANEL (IRP) INTERLOCKING JOINT N.T.S. N.T.S. MAX OVERHANG PER NOTE 114 SMS @ 2" FROM EA. END #8 xYz" ROOF HANGER FASTENER I ID ON S1.X 4 SEE TABLE 3 ON MAX, AND @ 32" O.C. MAX @ 12" D.C. PER 12/S4.3 „ I FASTENER 10d xYz" @EACH (4 MIN. PER PANEL INTERLOCK) S11A OR 53.1E _ PER FT SEE TABLE 3 ON PANEL INTERLOCK MIN SLOPE Ij S3.1A OR S3.1F ATTACHMENT --------- -- --- `^_------- TO BUILDING - - WHERE OCCURS ER PER 4B/S6.2 I PER S PER 54.1 OR 54.4 7L ROLL FORMED PANEL PER ROLL FORMED PANEL SHEEP 53.1A, 53.1 F. OR ` BEAM PER 54.1 & 54.2 10 x J�" @EACH 53.3 ; (3 x 8 BEAM SHOWN) VIE. PER SHEET S3.1A, S3.1F, AND S3.3 a L FORMED PANEL (RF) aEOERLL FORMED PANEL (RF) TO BLOCKING JOINT 3' = 1' 0" BEAM CONNECTION N.T.S. ALUM. ALLOY 3004-H36 ALUM. N1AY 653-75 JALUM. ALLOY 6063-T5 JALUM. ALLOY 3004-H36 1.625" `� � 'pp J 0.620' 1" GUTTER CUP 1.250' 0 24" O.C. MAX I o COMINUOUS "b� m "C" INSERT Nit 0.C32�' o C. ^ o' D.850" o TYP. ui ILQ w N I I N F� s� • ��a I ^o.o3e" 2.000" � " 00D 4.000 2.DOD" NOTES: 3.020" FAA& o0 1 750' BEAM PE 1. SEE 10/S5.1 FOR SPLICE DETAIL WHERE OCCURS. 2. THIS GUTTER IS USED WITH 6" OR B" FLAT PANS OR NOTES: 24" TRI-V PANS. 1. SEE 4/S5.1 FOR SPLICE DETAIL WHERE OCCURS. 2. THIS GUTTER IS USED WITH 6" OR 8" FLAT PANS OR 24" TRI-V PANS. DBL 2 x 6 1/2 x 0.03r T I -BEAM MAG GUTTER Bi 8.6' ROLL FORMED GUTTER FASCIA Biv 3'=1'-0` B7 W/ (1) V INSERTS 3"-0=1'" 3•�1�. 3"=1 '--0" ALUM. ALLOY 3004-H3fi A um. ALLOY 606376 ALUM. ALLOY 3004-H36 JALUM. ALLOY 5063-T6 STEEL ASTM A653-SS GRADE 50 G60 0.762" E I 2.908 R0.380' TYPI I I�8� llll I CONTINUOUS I I - 0.042 0 "C" INSERT I I N o o PER B7 I I o o D.062, oN co EA. SIDE I I N 15 � TYP I I 3.000' I I + - SPUCE I I 3.D00° WHERE OCCURS BEAM PER B6 3.000" C'7 8 BS T I -BEAM l e= 1 3' SQ. x 0.03Z ALUM. BEAM W/- f fl� l MAG BEAM W/ 'C' INSERTS 3"=1'-0" �� 12 GA. S1L V CHANNEL 3"=1'-O" ALUM. ALLOY 3004-H36 Ai UM. ALLOY 3004-H36 ALUM. ALLOY 6D63 75 ALUM, ALLOY 6053T6 SPUCE r WHERE OCCURS d 1.SD0' C. N n `pn O TYP. c O.D42" o c TYP. o 0.109" o o 0.085, o. °p N TYP NOTE: 3.000" ` 2.000" 4.000" 2.000" � 4.000" � 1. SEE 5/55.1 FOR SPUCE DETAIL WHERE OCCURS. F 3-000" 4.000' 3.0�00" MAX NOTE: MAX 1. SEE 6/S5.1 FOR SPUCE DETAIL WHERE OCCURS. DBL 3 x_$ x oA42' _ as AM DBL 2 x 81/2 x 0.D42' ! ov l r I -BE o3 4 I -BEAM _ 3' =1'--0' 3"=1'-O' 3"=1'-O" 2485 RAILROAD ST, CORONA, CA 928BO 951.736.4500 S 5885+ q LjcT �F OF CAL l�C DATE SIGNED: July 06, 2018 OrA T - ENClI�'�Sc11�F�' 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 �Ap OTM ES REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # 17.1071 DATE 04125/18 DRAWNBY RER CHECKED MDS f , OLID PANEL STRUCTURES: BEAM PROFILES FAN BEAM (19'-0" MAX. SPAN) BEAM/HEADER CEILING FAN AND/ OR LIGHT FIXTURE (MAX. 50 LB) (,\SECTION _ U SCALE his' V'-T HANGER CHANNEL OH NOTES: 1. FAN BEAM TO BE INSTALLED IN B" x 21�' FLAT PAN ONLY. 2 FAN BEAM CANNOT BE INSTALLED IN 24" TRI-V PAN, 12" W PAN OR 6" x 2h" FLAT PAN 3. WHEN USING 6" x 2V FLAT PAN, IT IS ACCEPTABLE TO REPLACE ONE SECTION OF DECK BY AN 8" x 2V' SECTION WITH A FAN BEAM. 4. SEE IAPMO 0505 FOR FAN BEAM AT IRP TYP. ATTACHMENT PER 4/S6.2 USE (2) 7/1e'm LAG SCREW TO FAN BEAM (CAN BE LOCATED IN (2) (E) STUDS CLOSER TO FAN ANY FLUTE OF AN B" FLAT PAN) BEAM ((4) SCREWS TOTAL) rWALL HANGER PER 12/S4.4 ATTACHMENT PER S3.1 x �s t � n 1� ADD L2 x 2 x 0.120" x 0'-2" LONG W/- #10 S.M.S. x )�' LONG TO LEDGER AND (2) #10 S.M.S. TO FAN BEAM FAN-BEAM_AT HANGEELCHANNEL f �1 SECTION _ SCALE: 3" = l'-O" I ALUM. ALLOY 3004-H36 STEEL ASTM A653-SS GRADE 50 G60 I " ALUMINUM BEAM & CONTINUOUS STEEL INSERT PER B14/54.2 TYP. o 0 z n. f I, 3.000" 4.00D" 3.000" MAX. rt V / WALL HANGER PER 12/S4.4 111 ff! #10 S.M.S. TOP AND BOTTOM AT HANGER CHANNEL WALL HANGER AnKbMENT ELEVATION SCALE 3" = 1'-0" B16 DSL 3 x 8 x 0.042' w/ 12 GA STL INSERT 3"=1,-T (2) #12 SMS, FAN BEAM TO GUTTER — FAN BEAM (2) 110 SDS DECK TO FAN BEAM (1) #12 SMS EACH SIDE OF FAN BEAM, DECK TO BEAM B1 OR 84 GUTTER PER S4.1 I 11 i — WHEN DOUBLE BEAM 4_-___-.i OCCURS, ATTACH FAN BEAM TO EXTERIOR BEAM FM BEAM E SECTION SCALE: 3" = 1'-O" � FAN BEAM SCALE: AS NOTED FAN BEAM ADD #10 S.M.S. AT BEAM HEADER BEAM/HEADER AT BEAM/HEADER D SECTION SCALE: 3" = 1'-O" FAN BEA F PROFILE SCALE: 6" = 1'-0" c a ALUM. ALLOY 3004-H36 1� 91 STEEL ASTM A653-SS GRADE 50 G&D 0 —14GA. CONTINUOUS STEEL INSERT 0.042' TYP N 0 2.824" 3.000" B13 3x8'x0.042' w/ 14 GA STL INSERT 3"=I'-D" ALUM. ALLOY 3004-H35 1.229. STEEL ASTM A653-SS GRADE 50 060 A. 1N000S L INSERT c a 2.824" 3-000" B�12* 2' L INSERT ALUM. ALLOY 3004-H35 STEEL ASTM A653-SS GRADE 50 G60 ALUMINUM BEAM & CONTINUOUS STEEL INSERT PER B13/S4.2 TYR Ll 3.000" 4.001)" 3.000" ^ MAX. B15 09L 3 x 8 x 0.042' w/ 14 G,4 STL INSERT 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 pFESS 1(yyq( S 5885 DATE SIGs ED~ July 06, 2018 eA 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 lAp Mo ES TM REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # 17-1071 DATE 04/2511 B DRAWN BY RER CHECKED MDS IAPM0 195 V 3.0 SOLID PANEL STRUCTURES: BEAM PROFILES S4.2 ASTM A5DD GRADE B ASTM A500 GRADE B IAIUM, ALLOY 3DD4-H36 ALUM- ALLOY 3OD4-H36 3" ALUMINUM OR STEEL POST PER PLAN N W O 0.032" 0 0.189" lbo o o h emu 00 0.042" 3.000" 3.000" 4.000" NOTE-- 2.000" 3.000" 2.000� IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. Nm SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF r0-042Z THIS DETAIL C1D HSS �€ x 4 x 3/16 cl HSS 3 x 3 x 3/16N SIDE PLATES 4�:TSQUM. POST ASTM A500 GRADE B ASTM A500 GRADE LAWLIM. ALLOY 6063-T6 JALUM. ALLOY 3004-H37f, 1.5D0` a 0.250"co Ia 0.250" o c 0.062" o n �; 7YP q - �RO.125 4 TYP. 3.000" 3.DD0" 3.000` o 4.000" NOTE-* NOTE: NOTE: IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF THE BEAM/COLUMN CONNECTION. THE BEAM/COLUMN CONNECTION. THE BEAM/COLUMN CONNECTION. C11 HSS 4 x 4 x 1/4 G8 HSS 3 x 3 x 1/4 � C5 3' MAG POST „� 8Q ALUM. POST _ . 0.. 3.1=1'-0° vc 3"=1'-0" 3"a 1'-D" ASTM A500 GRADE B STEEL A653 GRADE 50 CP50 JALUM. ALLOY 3004-436 3" ALUMINUM OR STEEL POST PER PLAN 1.500" o F O, :D�4811� 0.4D0" 0.313" o C.o M M - }R0.125 "' TYI'. w n 3.000" I 3.000' 0.032 d QTE; 2.000" 3.0130` 2.000" IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY Nam' SEC11ON Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. N= THE BEAM/COLUMN CONNECTION. SLEEVE SHALL EXTEND FROM THE FOUNDATION. TO THE UNDERSIDE OF SEE TABLE 1 ON S1.x FOR APPLICATION OF THIS DETAIL THE BEAM/COLUMN CONNECTION. r.n l HSS 3 x 3 x 5/16 f �e l 3' SO, STEEL POST f �e� l 0A3Z SIDE PLATES ALUM. ALLOY 3004-H361 ALUM, ALLOY 3004 H36 0.625" o �� 1.520" i'n ` 1.520" 0.625" r 0 0 0 0 - 0 0 0 00 0 N N p O O • _ o �! 0.730" CD N D.730 2485 RAILROAD ST, L0 L Lc;N ui N N CORONA, CA 92860 951.736.4500 o c� 0.038" c 0.039" 2.935' OTES: 2.935' N 1. SEE B1/S4.1 FOR SPLICE DETAIL WHERE OCCURS. 2. THIS GUTTER IS USED WITH 6" OR 8" FLAT' S 5885 1D NOT USED r` 1 NOT USED 6.5" ROLL FORMED GUTTER 5' ROLL FORMED GUTTER OR 25" PANS F o��I-lF``T ALUM. ALLOY 6063•T6 2.125" DATE SIGNED: July 06, 2D18 1.500" ATTACH SWIVEL HANGER TO BUILDING PER TABLE 5/56.1 - (2) #8 @ 16" O.C. TO MATCH LOC. OF 26030 ACERO, SUITE 200 4.125 4.860" LAG SCREW T MISSION VIEJO, CA 92691 .30 � (�) HANGER PER 6A/- f A 949.305.11501 FAX 949.305.1420 OR 6B/- o y � o .015" x s0' f m V-GR 2 .625' ATTACH EXTRUDED HANGER i TO EXISTING BUILDING PER c 1.375" 075' TABLES 3A, 3B, OR 4/S6.1 w TYP a I A p 2.1 xs" *.034 M NOTES: 1. USE OF THIS DETAIL IS LIMITED TO PROJECTION LENGTHS SHOWN IN TABLE 5/S6.1 2. USE OF THIS DETAIL IS NOT ALLOWED WHEN GROUND SNOW LOAD EXTRUDED HANGER CONNECTION NOT USED NOT USED > 25 PSF OR ROOF SNOW LOAD > 21 PSF '� ES (DURAKING PANED 3"=1' 0" 7 X=1'-o' X=I -0" TM ALUM. ALLOY 3004 H36 ',n� ALUM. ALLOY 646�T{ 2 707" REVISIONS 0 MARK DATE DESCRIPTION 2.495" 41 1,332" 1.937' .176" ATTACH ROLLED FORMED 1.500" .015" x 90' .092" 0.202" HANGER TO EXISTING j y Y G p 2 .250" 0.35 0.080" BUILDING PER TABLES 3A, 1.490" c N „'=T: �;' FASTENERS PER 3/S3.2 0.145" - 0.376" 0 J 1 4 STEL JOB # 17-1071 APPROVED 6" INSUL ,2ui O.D55° c DATE 04125118 ATTACH IR HANGER 2.336" ROOF PANELS PERTd--V02 0.3120 0 TO EXISTING BUILDING 0 DRAWN BY RER 0 2/G3.2 m 4.065" I 0 0.040" 0 N PER TABLES 3A, 3B, N 4.861"NTYP. N OR 4 S6.1 4.765" / 0.450' CHECKED KIDS t.os4 .300° svfr ��40 IAPMO V 3.0 8.25- 11.ST 1.550" R.08" S .625° 0 500" 0.563" 625" N 1.375" S ANEL STRUC ES: lollr.> FASTENERS PER 3/S3.2 O fxi tVIEMSER PROFILE off-- 6A 2.125" APPROVED 3" OR t.034 1.880" 44" INSUL ROOF 6B o PANELS PER 2/G3.2 li 92 ROLL FORMED HANGER $ IR HANGER B EXTRUDED SWIVEL HANGER CONNECTION S4.4 3"=1'-0" N.T.S. iTRI V, FLAT PAN, TRIPLE 6] 3"=1'-o' 2.875" Rpm. 0 0 o 0 0 0 0.060" N G O 000. NOTE: BRACKET IS 2%" LONG 4 V BRACKET AT COLUMN 1 'H' BRACKET N.T.S. 0.25� 0 0 cV r O O N O O O m O CV 0 q L a/Inw {.�w 2.pw. Q C] 2� ROOF BRACKET NOT USED L8 x S x 114 x Z' Y=1'-0" ` x'=1'4' 0 CV O O N O O c.i 0 O O N 2oo, 2,00,w Zpa. 0 a p• 2� (B)LSNOW BRACKET 3 NOT USED 12 x 8 x 1/2 x 2` ALUM. ALLOY :.�?4-:�� ALUM. ALLOY 3004-H36 9" 2'-0' 1• 3. g' 1" 1" 1" 1• 8" r I+P+++ --- #10 SMS#10 SMS MAK M- - - (8 TOTAL)(8 TOTAL)1+ + + +II+ + + + + + + t�L -J-- L-------------------- --_J L I 1" B" 1" 2" 1 r++ --- --++ ++ - - ----++ ++ + ++ ++I SPLICE POST CENTERED SPLICE I #12 SMS SPLICE I POST CENTERED SPLICE #12 SMS BEAM 84 ON SPUCE BEAM B4 (24 TOTAL) BEAM 81 ON SPLICE BEAM B1 (24 TOTAL) SIMPLE SPLICE MOMENT SPLICE SIMPLE SPLICE MOMENT SPLICE OTES: NOTES: 1. WHEN BEAM B4 IS USED AS AN ARCHITECTURAL GUTTER, A SIMPLE SPLICE CAN BE USED ANYWHERE. 1. WHEN BEAM B1 IS USED AS AN ARCHITECTURAL GUTTER, A SIMPLE SPLICE CAN BE USED ANYWHERE 2. WHEN BEAM B4 15 USED AS ABEAM, LOCATED DIRECTLY ON TOP OF COLUMNS, A SIMPLE SPUCE, CENTERED ON THE COLUMN 2. WHEN BEAM 81 IS USED AS A BEAM, LOCATED DIRECTLY ON TOP OF COLUMNS, A SIMPLE SPLICE, CENTERED ON THE COLUMN BELOW, CAN BE USED AT INTERIOR COLUMNS ONLY. IT CAN NOT BE USED AT EDGE OR EXTERIOR COLUMNS. BELOW, CAN BE USED AT INTERIOR COLUMNS ONLY. IT CAN NOT BE USED AT EDGE OR EXTERIOR COLUMNS. 3. WHEN BEAM 64 IS USED AS A BEAM, LOCATED DIRECTLY ON TOP OF COLUMNS, A MOMENT SPLICE CAN BE USED AT 1/3 OF 3. WHEN BEAM 61 IS USED AS A BEAM, LOCATED DIRECTLY ON TOP OF COLUMNS, A MOMENT SPLICE CAN BE USED AT 1/3 OF THE SPAN OF ANY BEAM, EXCEPT AT END BAYS AND OVERHANGS. THE SPAN OF ANY BEAM, EXCEPT AT END BAYS AND OVERHANGS. SPLICE DETAIL FOR MA4 (:�YSPLICE DETAIL FOR ROLL 10 GUTTER (BEAM B4) 1-1/2"=1'-0" FORMED 4ZJTTf=R (BEAM B7) ALUM. ALLOY 30D4-H36 0- 12" 1" 4• 1" 1" 4.' 1« 1" 16 1" 1" 16" 1' y Y2 MAX 1I Y. M L + - + SPLICE I I (8) #10 SMS SPUCE (8) Yz" BOLTS BEAM 83 I I POST CENTERED BEAM B3 MOMENT 5PLI ON SPUCE SIMPLE SPLICE NOTES: 1. A SIMPLE SPUCE, CENTERED ON THE COLUMN BELOW, CAN BE USED AT INTERIOR COLUMNS ONLY. IT CAN NOT BE USED AT EDGE OR EXTERIOR COLUMNS. 2. A MOMENT SPUCE CAN BE USED AT 1/3 OF THE SPAN OF ANY BEAM, EXCEPT AT END BAYS AND OVERHANGS. 6 SPLICE_ DETAIL FOR 4' 1 BEAM (B;rAM 83) 2'=1'-0" ALUM. ALLOY 3004-H36 12" S-T 1" 4 1" 1' 4" 1" 1" - - - - - - - - - - - - -- -- - - ----� + + I + + OO II I yz MAX I II + + I I + O D O a SPUCE (B) #10 SMS SPUCE (8) Yz" BOLTS BEAM 66 POST CENTERED BEAM B6 ON SPUCE SIMPLE 5PLICE MOMENT SPUCE NOTES 1. A SIMPLE SPUCE, CENTERED ON THE COLUMN BELOW, CAN BE USED AT INTERIOR COLUMNS ONLY. IT CAN NOT BE USED AT EDGE OR EXTERIOR COLUMNS. 2. A MOMENT SPLICE CAN BE USED AT 1/3 OF THE SPAN OF ANY BEAM, EXCEPT AT END BAYS AND OVERHANGS. B SPLICE DETAIL FOR T 1 BEAM (BEAM BO) TABLE 1 - MAXIMUM PROJECTION ASSUMING (E) JOIST SPACING = 24"OC MAX LUGSL (PSF) EXISTING FRAMING MEMBER AT ROOF OVERHANG BRACKET OFFSET "ID" 24^ 18" 12" 6" 2x4 FULL 12' 10" 19' 11" 28' D" 28' 0' 10 2x6 NOTCHED 2D' 6" 28' 0" 28' D" 28' 0' 2x6 FULL OR 2x8 NOTCHED 28' 0" 28' D" 28' 0" 28' 0' 2x8 FULL OR 2x1 D NOTCHED 28' 0" 28' 0- 28' D" 28' 0' 2x4 FULL T 9' 11,10, 19, 5" 28' 0' 20 2x6 NOTCHED 12' 3" 1T 10" 28' D' 28' D' 2x6 FULL OR 2x8 NOTCHED 19' 7" 27' 7' 28' 0" 28' D' 2x8 FULL OR 200 NOTCHED 28' 0" 28' D' 28-0- 28' D' 2x4 FULL T 4' 11' 3" 18' 7" 28' D' 25 2x6 NOTCHED 11, 8" IT D" 27' 1' 28' D' 2x6 FULL. OR 2x8 NOTCHED 18, 8" 26' 4" 28-0- 28' 0" 2x8 FULL OR 200 NOTCHED 28' 0" 28' 0- 28' D" 28' 0' 2(4 FULL 5' 11" 9' 4' 16 B" 28' 0' 30 2x6 NOTCHED 916. 14' 2" ZZ 11' 28' 0' 2x6 FULL OR 2x8 NOTCHED 15, 5" 22, D" 28, D" 28' 0' 2x8 FULL OR 2xl D NOTCHED 26 3" 28' 0" 28' 0" 28' 0' 4D 2x4 FULL 4' D' 6' 9' 12' 0" 25' 2' 2x6 NOTCHED 619. 1D' 5" 1T 6" 28' 0' 2x6 FULL OR 2x6 NOTCHED 11' 4" 16, 6" 25' 7" 28' 0' 2.8 FULL OR 20 D NOTCHED 19' 7" 27' 6" 28' 0" 28' D' 5D 2x4 FULL 2' 10" 5' 2- 9.8. 2D' 4' 2x6 NOTCHED 5' 1- 8' 2' 14' 2" 28' 0' 2x6 FULL OR 2x8 NOTCHED 8' 9' IT 0" 21' 6' 28' 0' 2x8 FULL OR 200 NOTCHED 156" 1 21' 11" NOTES: 1 - NOTCH CAN BE UP TO 1" IN 2x6, UP TO 1.5" IN 2x6 OR 2x1D. 2 - MAX (E) ROOF RAFTERS BACKSPAN IS ASSUMED TO BE 40 FT. 3 -FOR 10 PSF LUGSL, USE ROOF BRACKET 51S4.5 4 - FOR LUGSL 2 20 PSF, USE SNOW BRACKET 6/S4.5 TABLE 1A- MAXIMUM PROJECTION USING ROOF BRACKET PER4C/S4.5 LUGSL WIND SPEED 8 E)POSURE (PSF) 1108 13DC 11DC 120C 1D 17-0" 1 15-13" NOTE: WHEN U51NG ROOF BRACKET PER 4C/54.5, MAXIMUM PROJECTION SHALLBETHE5MALLESTPROJECTION FROM TABLE LAND TABLE 1A TABLE 1 B - MAXIMUM PROJECTION USING SNOW BRACKET PER 4DIS4.5 LUGSL WIND SPEED 8 EXPOSURE (PSF) 110B, 110C 1208, 130B 120C 130C 10 24'-0" 24'-D' 21'-D" 20 20'-D' 19'-9" 1 T-3" 25 19 -3' 19'-3" 1 T-9" 30 16'-3' 16'-3" 16'-3" 36 13'S' 13'-9" 13'4 4D 12'3' 1T-3" 12'-3" 42 11'-9' 11'-9" 11'-9" 50 10'' 10'-0" 1 V-0" NOTE: 'WHEN USING SNOW BRACKET PER 4D/54.5, MAXIMUM PROJECTION SHALL BE THE SMALLEST PROJECTION FROM TABLE 1ANDTABLE 1B TABLE 2 - NUMBER OF SIMPSON A34s EA END REQUIRED AT ROOF PANEL OR RAFTER CONNECTED TO EXISTING ROOF OVERHANG (EA. END) TRIB 10 PSF 2D PSF 25 PSF 3D PSF 41) PSF 50 PSF WIDTH LUGSL LUGSL GSL GSL GSL GSL 1 1 6 1 1 1 1 1 2 7' 1 1 1 1 1 2 8' 1 1 1 1 2 2 9' 1 1 1 1 2 2 10, 1 1 1 2 2 2 11' 1 1 1 2 2 2 2 12' 1 1 2 2 2 1 2 'NOTES: 1 - USE (8) SIMPSON SD9112 SCREWS INTO EACHA34 :2 - WHEN USING (2) A34s AT EA END, PRDVIDE 2x FULL DEPTH WOOD SCAB, FULL LENGTH OF RAFTER TAIL, WI 10d @ 12" O.C. MAX, T&B, STAGGERED (WOOD SCAB TO RAFTER) 3 - A NUMBER 1 IN THIS TABLE MEANS THAT 2 A34s TOTAL ARE REQ'D. A NUMBER 21N THIS TABLE MEANS THAT A34s TOTAL ARE REQ'D TABLE 3A - FASTENERS REQUIRED AT HANGERS PER DETAILS 9, 11, AND 12/S4.4 TO EXISTING WOOD STUD WALL FRAMING TRIB IDPSF 20 PSF 25 PSF 30 PSF 40 PSF 50 PSF WIDTH LUGSL LUGSL GSL GSL GSL GSL 5' A A A A A A 6' A A A A A B T A A A A B B 8' A A A A B C 9' A A A A B C 10, A A A B C C 11' A A B B C C 12' A B B B C C A - (2) 1/4" LAG SCREWS W/ 2'/2" PENETRATION IN WALL STUDS B - (2) 5116" LAG SCREWS W12NZ' PENETRATION IN WALL STUDS C - (2) 7116" LAG SCREWS W/ 311 'PENETRATION IN WALL STUDS NOTES: 1 -ANCHORS ARE TO BE SPACED AT 16" 0 C. MAX HORIZONTALLY IN DIRECTION PARALLEL TO WALL TABLE 3B -FASTENERS REQUIRED AT HANGERS PER DETAILS 9, 11, AND 12/S4.4 TO EXISTING 2x LEDGER OR FASCIA TRIB WIDTH 10 PSF LUSL 2D PSF LUSL 25 PSF GSL 30 PSF GSL 40 PSF GSL 50 PSF GSL 5' A-16'oc A-16'oc A-16"oc A-16"oc A-15"oc A-12"oc 6' A-16"oc A-16'oc A-16"oc A-16"oc A-12"oc A-8"oc 7' A-16"oc A-15'ec A - 16" ocl A-12"oc A-8"oc A -Toc 8' A-16"oc A-16'oc A-16"oc A-12"oc A-8"oc A-8"oc 9' A-16"oc A - IT= A-12"oc A-12'oc A-8"oc A-6"oc 11Y A-16"oc A-12'oc A-12"oc A-8'oc A-Woc A-6"oc 11' A-16"oc A-12"oc A-8"oc A-8'oc A-6-oc A-6"oc 12' A-16"0c A-8-oc A-6"oc A-8'oc A-6'oc C-6"oc A (2)114" LAG SCREWS C (2) 7/16" LAG SCREWS B (2) 5116" LAG SCREWS D (2) l/2' LAG SCREWS ALL FASTENERS TO HAVE 1.5" PENETRATION INTO (E) 2x LEDGER OR FASCIA TABLE 4-ANCHORS INSTALLED INTO THE SIDE OF 6 IN THICK MIN CONCRETE OR CMU WALLS :IN CONCRETE, USE 1/2" DIA SIMPSON STRONG-BOLT2, STAINLESS STEEL, WITH 3" MIN EMBED, INSTALLED PER ICC-ESR 3D37. 'IN CMU, USE 1/2' DIA SIMPSON WEDGE -ALL, STAINLESS STEEL, WITH 3 318" MIN EMBED, INSTALLED PER ]CCESR-1396. MAXIMUM ANCHOR SPACING 10, 20, 25 PSF LUGSL 30 PSF GSL 40 PSF GSL 1 50 PSF GSL 46" M' 36 24' USE 3" SQ.xl/4" STAINLESS STEELWASHER WHEN INSTALLING NEW WOOD LEDGER AGAINST EXISTING CONCRETE WALL TABLE 5- MAXIMUM PROJECTION WHEN USING EXTRUDED SWIVEL HANGER PER 6/S4.4 LI/GSL s Lag Screw Diameter Wind Speed and Exposure 110E 1]OC 120B 120C 130B 130C 1/4" A 13' - 6" 12 - 6" 12 - 6" If - 0' 11' - 5' W - 0" 10 5/16" 0 17 - W 15 - e" 14'-0" W - 0" 14- 9' 17. 6" 3/8"0 18'-0" 1V-0" 16'-6" 15-0' 15.0' 13'-6" .V4" o JU _ D" 5 _ () s - 6" a' _ 6" 8'- 6" 9- D" 20 5/16"0 12'-61 11'-6'" 10-6' 10-6" IT-0" 10'-0' 3/8" o 13- 0" 12 - a' 12 - 6" 11 - 6' 1T - 6" 10' - 6" 25 1/4'o T-6" 9'-a' 9"-a' 9-5' gr- IT, 9-T 5/16°d 12-a' 11'-6" W-6" la-6' 10'-6" 10f-a' 3/8"6 12'-6" Ty -a' 12-W 11'-a' 11'.W la•6" NOTE: FASTENERS W/ 3" PENETRATION INTO WALLSTUDS TO BE SPACED AT 16" O.C. MAX FASTENERS W/ 11/z" PENETRATION INT02K WOOD FASCIA TO BE SPACED ATS" O.C. MAX NOTE: WHEN (E) WALL HAS AN OPENING UNDER THE ATTACHMENT OF THE PATIO TO THE EAVE OR WALL, SITE -SPECIFIC ENGINEERING IS REQUIRED TO VERIFY ADEQUACY OF THE EXISTING STUD WALL FRAMING (INCLUDING HEADER SIZE) WHEN THE FOLLOWING CONDITIONS OCCUR: FOR LUGSL = 20 PSF MAX: COVER PROJECTION > 1 WAND OPENING IN WALL WIDER THAN 8' FOR GSL = 50 PSF MAX: COVER PROJECTION > 14' AND OPENING IN WALL WIDER THAN 6' NO ADDITIONAL SITE SPECIFIC ENGINEERING IS REQUIRED WHEN EXISTING OPENINGS / PROJECTIONS ARE SMALLER THAN THOSE STATED ABOVE. ALLOWABLE CLEAR DIMENSION TO BEAM D SEE TABLE 1A ON S6.1 SEE TABLE 1 ON 56.1 2 x Eh" or 3 x 8 WOOD FILLED ALUMINUM LEDGER HANGER PER 9, 11, OR 12/54.4. FASTENERS PER TABLE 36/56.1. SOLID PATIO COVER OR ALUMINUM RAFTER_5�� ALTERNATIVE ROOF 4" BRACKET ORIENTATION MIN. MIN ROOF BRACKET PER 5/54.5 (3) Ys"0 LAG SCREWS W/- 1%" PENETRATION (3) VO LAG SCREWS W/- 4" PENETRATION 6 ALTERNATIVE ROOF BRACKET Mom' LOCATION AND/OR ORIENTATION L;;;� SEE NOTE 4 (E) BLOCKING BETWEEN CONT. RAFTERS OR TRUSSES, WHERE OCCURS WALL SEE NOTE ABOVE SAVE OH LE) RAFTER OR TRUSS 13ACKSPAN 24 MAX 6-0 MIN 40'-0 MAX NOTES: 1. EXISTING ROOF DESIGN LOADS: RDL = 3 PSF (MIN) TO 8 PSF (MAX) 2. NEW PATIO DESIGN LOADS: LL = 10 PSF MAX (NO SNOW LOAD) 3. PLACE "SIKA FLEX" OR SIMILAR MATERIAL BETWEEN BRACKET AND COMPOSITE SHINGLE ROOFING TO PROVIDE SEAL 4. WHEN THE BRACKET IS INSTALLED AT ALTERNATE LOCATION SHOWN, USE TABLE 1 FOR D=6". 5. USE THIS DETAIL WITH ROOF BRACKET PER 5/54.5 AND TABLES 1 AND to ON 56.1. C CONNECTION TO TOP OF EXISTING ROOF LL =10 PSF MAX ALLOWABLE CLEAR DIMENSION TO BEAK SEE TABLE 1B ON 56.1 HANGER PER 9, 11. OR 12/54.4. FASTENERS PER TABLE 3B/56.1. SOLID PATIO COVER OR ALUMINUM RAFTER - (3) Yz"0 LAG SCREWS W/- 4" PENETRATION 3 x 8 WOOD FILLED ALUMINUM LEDGER ROOF BRACKET PER 6/S4.5 (3) V-0 LAG SCREWS W/-21¢" PENETRATION (E) BLOCKING BETWEEN CONT. RAFTERS OR TRUSSES, WHERE OCCURS (E) WALL SEE NOTE ABOVE NOTES: 1. EXISTING ROOF DESIGN LOADS: RDL = 3 PSF (MIN) TO 8 PSF (MAX) 2. NEW PATIO DESIGN LOADS: GSL = 50 PSF MAX 3. PLACE "SIKA FLEX" OR SIMILAR MATERIAL BETWEEN BRACKET AND COMPOSITE SHINGLE ROOFING TO PROVIDE SEAL 4. BRACKET MUST BE ORIENTATED TOWARDS ROOF EDGE AS SHOWN. 5. USE THIS DETAIL WITH ROOF BRACKET PER 6/54.5 AND TABLES 1 AND 16 ON 56.1. 6. VERTICAL LEG OF BRACKET SHALL BE LOCATED 6" MAX. FROM FACE OF WALL, ON EITHER SIDE OF WALL D CONNECTION TO TOP OF EXISTING ROOF GSL = 50 PSF MAX 4 CONNECTION TO (E) BLDG 3/4"=1'-0° DECK/ DIRECT COLUh BEAM TRIBUTARY AREA (E) BLDG a BEAM j / COLUMN TRIBUTARY T� a AREA EQ. 1, EQ. L DECK/RAFTER DIRECTION PLAN � SlrAM BRACxIrT N.T.S. FASTENERS, SEE TABLES 3A & 4 ON 56.1 AND NOTE 1 E 1" THICK MAX LATH AND HANGER PER7S4.44 PLASTER WOOD SIDING 1, 2, OR X( STUCCO SEE NOTE 2 SOLID COVE (E) 2 x WOOD STUD WALL SIM AT CONCRETE, BRICK OR MASONRY WALL SEE NOTE ABOVE j) 1 MIN. FASTENER PER 53.2 0L NOTES: 1. FASTENER TO BE INSTALLED AT CENTER OF (E) WOOD STUDS 2. PLYWOOD SHEATHING DOES NOT COUNT TOWARD THIS 1" MAX. 3. DETAIL IS VALID WITH CONNECTION THROUGH (E) WOOD LEDGER ALONG STRUCTURE PROVIDED THAT THE MINIMUIJ FASTENER PENETRATION IN WALL STUDS PER TABLE 3A/56.1 IS SATISFIED. B WALL CONNECTION "D" SEE TABLE 1 ON 56.1 SIMPSON A34 EA END SEE TABLE 2 ON 56.1 FOR NUMBER OF A34 HANGER PER 6/54.4. READ AT EA END (E) BLOCKING FASTENERS PER TABLE 3B ON 56.1 AND NOTES 2 AND 3 BETWEEN CONT. RAFTERS OR TRUSSES SOLID PATIO COVER - �- ADDWO 2 x FULL DEPTH ` RA TRUSS 2 WOOD SCAB, WHERE tj 1���_ RAFTERS @ 24" OC EXISTING FASCIA BOARD 2-A34's ARE REQUIRED PER TABLE 2 ON 56.1 E) WALL SEE NOTE 3 ON 56.1 SEE NOTE ABOVE ABLE CLEAR DIMENSION TO BEAM I, (E) EAVE OH RAFTER OR TRUSS BACKSPAN SEE TABLE 1 ON SG.1 24 MAX 6'-0" M!N 40'-0 MAX NOTES: 1. EXISTING ROOF DESIGN LOADS: RDL - 3 PSF (MIN) TO 8 PSF(MAX) RLL/GSL = 10, 20, 25, 30, 40 OR 50 PSF 2. FASTENERS TO BE LOCATED 4" MIN FROM SPLICE IN (E) FASCIA BOARD AND 2" CLEAR FROM TOP AND BOTTOM OF (E) FASCIA BOARD. A COHNECTiON TO EDGE OF EXITING ROOF (E) STUD WALL V 3"x 8" x 0.042" HEADER (3) )z'O LAG SCREW TYP. a _ FA SIDE SMS a N PLASTER OR WOOD SIDING OR 1, 2 OR 3 COATS OF STUCCO 3" x 8" RAFTER BRACKET NOTES• SEE NOTE 6 1. USE OF THIS DETAIL IS LIMITED TO THE FOLLOWING: FOR LL/GSL = 10 PSF, MAX TRIB AREA TO CONNECTION = 100 FTZ FOR LL/GSL = 20 OR 25 PSF, MAX TRIB AREA TO CONNECTION = 55 FT2 FOR GSL = 30 PSF, MAX TRIG AREA TO C0NNECTKIN - 45 FT' FOR GSL > 30 PSF, DETAIL IS NOT ALLOWED 2. SEE PLAN FOR DEFINITION OF TRIBUTARY AREA. 3. BEAM MUST LINE UP WITH EXISTING FULL HEIGHT WALL STUD. NO OPENING ALLOWED UNDER CONNECTION. 4. USE (2) V HILTI KB-TZ W/ 4' EMBED @ CONC WALL, W/ 6" SPACING 5. USE 10" TALL BRACKET & (2) 3C HILTI KB-3 W/ 4" EMBED @ CMU WALL W/ B" SPACING 6. PLYWOOD SHEATHING DOES NOT COUNT TOWARD THIS 1" MAX. 2 x Eh x .024" SEE TABLE FOR FASTENER RAFTER TO RAFTER AND FASCIA 14 S.M.S. TOP & BOT 2 x Eh ALUM. (2 TOTAL) AT EA. RAFTER BRACKET RAFTER TAIL OPTIONAL LATTICE GUTTER TUBE ER ROOF PANEL • z� @24" O.C. �' MAX #14SMS@ �� • 12° OC T&B 12WI I. -V SEE TABLE 1. SEE TABLE FASTENERS "L" "D" WITH LATTICE NO LATTICE (4) #10 (3) #8 2'-D" 1" (6) #10 (4) #8 3-0" 2" (12)#10 (2 ROWS OF 6) (8)#B (2 ROWS OF 4) NOTE: 1. THIS DETAIL IS LIMITED TO 30 PSF MAX LL/GSL 2. FASTENER SPACING = 3/4" MIN RAFTER TAIL TO GIUTI'ER (D-1"=lw $ NOT USED scAIF NOTCH RETURN PORTION OF THE TOP FLANGE OF THE BEAM (AND INSERT WHERE OCCURS) AT CONNECTION TO COLUMN 0. 3 x B x 0.42 BEAM OR 3" STEEL BEAM (3) %"0 THRU-BOLTS @ B6, B7 OR B8 (6)-#14 SOS EA SIDE (2)"0 THRU BOLTS @ B3 TOP & BOT TOTAL = 24 I BEAM B3, 86, 87, OR B8 PER S4.1 NOTCH FULL BOTTOM FLANGE OF I BEAM (AND INSERT WHERE OCCURS) ON ONE T PER 1 54.5 H BRACKET / SIDE OF WEB AT CONNECTION TO COLUMN OR 3" OR 4" SQ. STEEL POST PER S4.3 ALUM. OR STEEL POST NOl£: DO NOT NOTCH BEAM AT END COLUMNS WITH OVERHANG I BEAM TO POST 'W BRACKET TO POST BE4M 91 OR 84 OPTIONAL SEE NOTE 1 1 2' MAR SPLICE DECORATIVE FASCIA (WOOD, ALUM., WHERE OCCURS (6) #14 SMS 0 EACH (INT COL ONLY) OR HARDBOARD) HEADER TO COLUMN (12) FASTENERS PER OUBLE BEAM 89, (4)114 x V S.M.S. COHNECTHIN B10, B12, B15 OR B16 5/8"0 HOLE WITH II I (4)#14 SMS EA SIDE PLASTIC PLUG, AS I 11 I REO'D, TYP. IT IS •� ACCEPTABLE TO I I 3" SQ POST U BRACKET PER 4/54.5 USE ONE HOLE INSTALL SEE NOTE 2 SEEVERAL CREWS, Ia If 0l TYP. I 11 I (2) #14 SMS EACH I FCC 1 SIDE T&B 032" I ARCHITECTURAL SIDE 1. USE SIMILAR DETAIL AT 3 x 3 OR 3 x 8 BEAMS. O.C. PLATES, WHERE OCCUR, 2. U BRACKET IS NOT REQUIRED IF SIDE PLATES PER 3/S6.3 SHALL STOP & FLUSH OR H BRACKET PER 1/S6.3 ARE PROVIDED. BELOW BEAM 3" OR 4" SO. POST BEAM TO POST I 1 DBL BEAM TO COL � n 3" WIDE BEAM TYP 92, B5, B11, 813 OR B14 1 2" MAR SPl1C£ 3" OR 8" BEAM (6) #14 SMS EA SIDE WHET7£ OCCURS SMS PER ELEVATION, TYP. AT SIDE PLATE SP3 T (INT COL ONLY) (8) #14 SMS EA. SIDE p %e"0 PLASTIC PLUG, TYP. AT SIDE PLATE SP4. SEE NOTE 1. �i e i a PROVIDE FULL BEARING OF BEAM ON POST. n° %'0 HOLE WITH PLASTIC PLUG, AS REQ'D, TYP. IT IS ACCEPTABLE TO i�2" SIDE PLATE EA SIDE USE ONE HOLE TO INSTALL SEVERAL SCREWS, TYP. 3" SQ. POST BETWEEN (2) #14 SMS EA SIDE AT 6j' SIDE PLATE EA. SIDE, SEE BOTTOM AND AT 32" OC MAX. TABLE 1 ON S1.x OR L1.x SIDE PLATES OPTIONAL STYROFOAM INFILL OF B SECTION ELEVATION SQ. POST BETWEEN A EFtVAiION SIDE PLATES CAN STOP BELOW SIDE PLATES THE CONNECION TO POST CONNECTION NOS` 3 AT SCREWS UTHE BFLAT 3/4"=1'-O" INTO POR11ONC/ VERTICAL WALL OF BEAM — 3" STEEL POST I I STEEL INSERT PER R' 4/S7.2 AT POST^ TYPE C7, CB, & C9 I 3" OR 4" STEEL. POST - ADJACENT ADJACENT TYR I BOLTS PER TABLE 2 ADJACENT GRADE 4 i 4/S7.2 z aTYP.CL jilt— LdLnn • dF IYMINPER I1 m At 'o TABLE 1 ALTERNATE FOOTING DIMENSIONS FTG(IN) W=L=D (SEE NOTE,1) A I WxLxD (SEE NOTE 2) Alt WxLxD (SEE NOTE 3) Alt 3(ATTACH ED) WxLx18" (SEE NOTE 4) Alto WxLx18" (SEE NOTE 5) AltS WxLx24" (SEE NOTE 6) AIt6 WxLx30" (SEE NOTE 7) AIt7 WxLx36" (SEE NOTE B) Alt WxLx42" (SEE NOTE 9) 18 IsxIsx28 12x12x22 18x19xIs 18xISx18 16x16x24 14x14x30 13x13x36 12x12x42 2D 20x20x20 12x12x I2 21 x21x 18 25x25x3B 19 x19 x24 17 x17 x30 15x15x36 24x14x42 22 22x22x22 16x16x16 25x25x1B 33x33x1B 21x21x24 19x19x3D 17x17x36 16x16x42 24 24x24x24 20x20x 20 28 x28x 18 43 x43 x16 24 x24x24 22x22x30 2Dx20x36 IBx 18x42 26 26x26x26 23x23x23 32x32x18 31x31x24 24x24x30 22x22x36 21x21x42 26 28x2Bx28 25x25x25 35x35x18 38x38x24 27x27x30 25x2Sx36 23x23x42 30 30x30x30 26x28x26 39x39x18 3Dx30x30 28x28x36 26x26x42 32 32x32x32 30x30x30 43x43x18 37x37x30 30x30x36 28x28x42 34 34x34x34 32x32x32 47x47x18 33x33x36 31x31x42 36 36x36x36 34x34x34 S1x51x18 36x36x36 34x34x42 36 38x38x36 37x37x37 SSX55x16 43x43x36 36x36x42 40 40x40x40 39x39x39 6Dx60x18 39x39x42 42 42x42x42 41x41x41 64x64x18 42x42x42 POURED I I POURED Jill 1 T. NOTES: CONCRETE CONCRETEm A36 THREADED 1-"FTG (IN)" IS THE FOOTING DIMENSION REFERENCED IN BEAM SPAN TABLES ON SHEETS SBxz.x OR LBxxx. FOOTING FOOTING ROD W/- NUT EA. SIDE 2-"ALT 1" 15 THE FOOTING DIMENSION BASED ON THE"FTG(IN)" DIMENSION. NDTETHATW=D=L WIDTH=LENGTH IN OF COL OR #4 REBAR, 3 -"ALT 2" 15 THE ALTERNATE F007ING DIMENSI ON REQUIRED WHEN A 3.S" MIN THICK SLIB 15 PRESENT ABOVE THE FOOTING. NOTETHATW=D=L H Ll 5 SCHEDULE GR 40 MIN. SECURED 4-"ALT3"IS THE ALT'ERNATEFOOTING DIMENSION REQUIRED WHENT'HEF007ING15KEPT TOANI6"DEPTH FOR UPLIFT DESIGN ONLY. THIS VALUE IS TO BE USED IN BEAM SPAN TABLES IN BEAM SPAN TABLES IN PLACE ONLY AT ATTACHED PATIO STRUCTURES. NOTE THATW=LANDD=18". NOTES: 5 - "ALT 4" IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPT TO AN 16" DEPTH. NOTE THAT W=L AND D=18". 1. THIS DETAIL CAN BE USED FOR STEEL POST TYPES C6, C7, C8, OR C9. NOTES: 6 -ALT 5" 15 THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPTTO AN 24" DEPTH. NOTE THATW--LAND D=241% 2. THIS DETAIL SHALL NOT BE USED FOR ALUMINUM POST TYPE C1 OR 1. THIS DETAIL IS TO BE UP FOR POST TYPES CID & C1 1. 7-"ALT6"ISTHEALTERNATEFOOTNGDIMENSIONREQUIREDWHENTHEFOOTINGISKEPTTOAN3D"DEPTH.NOTETHATW=LANDD=3D". ALUMINUM POST TYPES C2 OR C5 PER TABLE 2 ON S7.1. 2. THIS DETAIL POST TYPES C6, C7, CB, C9 8-"ALT7"ISTHEALTERNATEFOOTINGDIMENSIONREQUIREDWHENTHEFOOTING15KEPTTOAN36"DEPTH.NOTETHATWdANDD=36". 3. IT 15 ACCEPTABLE TO EMBED THE STEEL POST DIRECTLY INTO THE FOOTING PER TAB S7.1. 9-"ALTB"ISTHE ALTERNATE FOOMNGDIMENSIONREQUIRED WHEN THE P007INGISKEPTTOAN42"DEPTH.NOTETHATW=LANDD=42". PER 5/S7.1 INSTEAD OF USING THE POST SLEEVE SHOWN IN THIS DETAIL 3. THIS D SHALL NOT BE USED FOR AL POST TYPES C1, C2, 4. THIS DETAIL CAN BE USED ON A SLAB ON GRADE PER B/S7.1 AND PER OR C TABLE 2 ON S7.1 7 STEEL POST SLEEVE CONNECTION S EL POST EMBEDDED ❑CONCRETE FOOTING S FOUNDATION TABLES TO CONCRETE FOOTING 1"=1'-0" TABLE 3 - (MAX WIND SPEED: 130MPH, EXP C) MAXIMUM POST SPACING WHEN PATIO COVER IS INSTALLED ON SLAB ON GRADE TRIB WIDTH ROLLED FORMED PANS (RF) IRP LL/GSL(psf) GSL(psf) LL/GSL(psf) 10 psf 20 psf 2S psf 30 psf 10 psf 20 psf S. 13'-7" 11'-0" 1OL4" W-O" 12'-6" SO'-0" 6' 111-4" 91-9" 91-D" 8'-4" 10'-S" B'-9` 7' 9'-S" 9.-0" 8'-D" 7'.6" 9'-0" R'-0' 8, B,-6" 8,-6• V-6" T-0" 1 7'-10" 7'•6' 9' 7'-7" B'-0" 7LD" NP 7-13" 7-0. 30' 6'-9" 7' 6" N.P. NP V-3" 6'•5` 11' W-2" 7' 0" NP NP S'-S" V-0" 12' S'-R" 6'-fi" NP NP S'-3" S'-6" 3 STEEL OR ALUMINUM POST SEE NOTE 6 ADJACENT GRADE 7' BRACKET PER 1/S7.2, WHERE OCCURS 2/S7.2 OR 3/S7.2 5" EXISTING OR NEW SLAB ON MIN. j i GRADE. f c = 2,500 PSI MIN. I' x ., Imo) �,, I— IRS E OF SLAB BOLTS PER TABLE 2 ON S7.1 WHERE OCCU NOTES: 1. THIS DETAIL CAN BE USED — POST TYPES C1, C2, C5, OR C6. 2. THIS DETAIL SHALL NOT BE USED FOR FREESTANDING STRUCTURES TABLE 2- ANCHORAGE SCHEDULE (ATTACHED STRUCTURES ONLY) BRACKET DETAIL POSTTYPE FTG (IN) ANCHOR BOLTS (SEE NOTE 2) SEE NOTES ALUMT 1/57.2 C3 SOG (2)-3/8"dia w/ 1-7/8" embed ALUM T 1/S7.2 CS ALL (21-3/8" dia w/ 2-7/8" embed ALUM T 2/57.2 C2 SOG (2)-3/8" d1a w/ 1-7/18" embed 3 ALUM T 2/S7.2 C2 ALL (2)-3/8" dia w/ 2-7/8" embed 3 ALUM T 2/57.2 CS SOG (2)-3/8" dia w/ 1-7/8" embed 3 ALUM T 2/57.2 CS ALL (2H3/8" dla w/ 2-7/8" embed 3 STEELT 3/S7.2 C6 SOG (2)-3/8" dia w/ 1-7/8" embed STEELT 3/S7.2 C6 522" (2)-3/8"dlaw/2-7/8"embed 1 1,3,4 STEELT 3/57.2 C6 524" (2)-1/2" dia w/ 3-1/4" embed 1,3,4 STEELINS 4/57.2 C6 530" (4)-1/2"dia w/3-2/4"embed 1,4 STEEL I NS 4/57.2 C6 5 34" 14)-5/B"dia w/ 4" embed 1,4 STEEL INS 4/S72 C6 a 35" (4)_3/4" dia w/ 4-3/4" embed 1,4 STEEL I NS 4/572 C7, CB, C9 ALL (40/4" di a w/ 4-3/4" embed 1,5 EMBED 5/57.1 C10,C11 I ALL N/A "T" BRACKET PER 1/S7.2, 2/S7.2, OR 3/57.2. 3" STEEL OR ALUMINUM POST BOLTS PER TABLE 2 ON 57.1 ADJACENT GRADE TYP. I o � w fn z POURED CONCRETE FOOTING p- +. AUc�n a• w w V) N tz m ,c NOTES: AND/OR COMMERCIAL APPLICATIONS. NOTES: WIDTH = LENGTH IN 1 - "NP"INDICATES THAT A FOOTING IS REQUIRED, AND THE PATIO 3. THIS DETAIL SHALL NOT BE USED FOR POST TYPE C7, C8, C9, CIO. 1- "FTG (IN)" 15 THE FOOTING DIMENSION REFERENCED IN BEAM SPAN TABLES ON g� FTG, SCHEDULE INI COVER CAN NOT BE SUPPORTED ON A SLAB ON GRADE C1 1. SHEETS SBxx.x BEAM SPAN TABLE 2-FORLIVE ORSNOW LOADS HIGHER THAN THE ONES SHOWN ON 4. SEE "SLAB ON GRADE USED AS A FOUNDATION SYSTEM" NOTES ON 2- ANCHOR BOLTS SHALL BESIMPSONSTRONG SOLT2,STAINLESS STEEL (ICC-ESR THIS TABLE, AFOOTING ISREQUIRED AND THE PATIOCOVER CANNOT GO.1 FOR MINIMUM OVERALL DIMENSION OF SLAB AND ACCEPTABLE 3037) NOTES' BE INSTALLED ON SLAB ON GRADE. CRACKING AND CONTROL/EXPANSION JOINTS CRITERIA 3-ITISACCEPTABLETOUSE THESTEELINSERT PER 4/57.21NSTEADOFTHE 1. THIS DETAIL CAN BE USED WITH POST TYPES C1, C2, C5, OR C6. 3 - WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE 5. WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE ALUMINUM TPER 2/572 FOR POSTTYPES C2 AND C5 OR INSTEAD OF THE STEELT 2. THIS DETAIL SHALL NOT BE USED FOR FREESTANDING STRUCTURES. (RESIDENTIALAPPUCATIONSONLY),THE MAXIMUM POSTSPAGNGIS (RESIDENTIAL APPLICATIONS ONLY), THE MAXIMUM POST SPACING IS PER3/S7.2FOR POSTTYPEC6.SOLTSCANREMAIN ASSPECIFIED INTHISTABLE 3. THIS DETAIL SHALL NOT BE USED FOR POST TYPE C7, C8, C9, CIO, THE LOWEST OF THE "MAX POST SPACING (SPAN)" SHOWN ON SB.XX.1 BUT (4)80LTSSHALLBEUSED. C11. THE LOWEST OF THE"MAX POST SPACING(SPAN)"SHOWN ABOVE AND THE MAXIMUM POST SPACING SHOWN IN TABLE 3. 4-ITISACCEPTABLE TOUSETHEEMBEDDED POST DETAIL5/S7.1INSTEAD OFTHE AND THE MAXI MUM POST SPACINGS SHOWN ON SHEETSS.XX.X 6. ANY POST SIZE FOUND IN TABLE ON SHEET SB.xx.x AND MATCHING STEELI NSERT PER 4/S7.2 OR STEELT PER 3/S7.2 FOR STEEL POSTS C6. TRIBUTARY WIDTH AND MAX. POST SPACING FROM TABLE 3 CAN BE 5-ITISACCEPTABLE TOUSETHEEMBEDDED POST DETAIL5/57.11NSTEADOFTHE USED. EXAMPLE: 10 psf U., 110 mph WIND LOAD CAN USE A COLUMN C1 PER S8.10.1 FOR BEAM B3, ATTACHED COVER. 57EELINSERT PER 4/S7.2FOR STEEL POSTS C7, CB AND C9. T BRACKET CONNECTION ANCHORAGE OF POSTS T BRACKET CONNECTION o V 4 TO SLAB ON GRADE 1°=r-D• TO SLAB OR FOOTING TO CONCRETE FOOTING r=1'-o" ASTM A500 GRADE B 4 � N n INSERT TO PLANS" BASE PL 3" STEEL POST 0.188" THICK MIN CD HSS INSERT o (3) Y4'0 BOLTS cD -- 10" SO. x %" BASE PL T,O,C, NOTES: ELEVATION 1. THIS BRACKET IS TO BE USED WITH POST TYPE C7, CS & C9, AND WITH C6 (WHEN FOOTING SIZE IS 25" OR LARGER). 2. SEE TABLE 2 ON S7.1 FOR ATTACHMENT TO FOOTING/SLAB. 3. INSTALL 1Y x 14 x Ya HDG WELDED WASHER PLATE AT ANCHORS SMALLER THAN 3 O. 4. THIS BRACKET CAN ALSO BE USED FOR POST TYPE C2, C5, OR C6 (ALL FOOTING SIZES) PER TABLE 2 ON S7.1 AND 7/S7.1. ��TEEL POST SLEEVE FOR POSTS C8, C7, C8, C9 ALUM ALLOY 6063 T5 2 OR TEK CR .,IMIS ��� I OR TEK SCREWS, EA. SIDE, TYP. 0 0 i I I WO HOLE EA. SIDE i 0.085" TY1 0.750" 5.662' TYP. 1. BRACKET LENGTH IS 2,75" 2. THIS BRACKET IS TO BE USED WITH POST TYPE C1, WITH OR WITHOUT SIDE PLATES PER SP3 OR SP4. 3. SEE TABLE 2 ON S7.1 FOR ATTACHMENT TO FOOTING/SLAB. 4. INSTALL 1Y x 11; x h HDG WASHER PLATE AT ANCHORS FOR 130 MPH MINUM T-BRACKET POST C1 ALUM ALLOY 60637T6 4-J14 SMS , 406' OR TEK SCREWS, *I I� EA SIDE, TYP.. WO HOLE EA SIDE i 0.094 TYP. 0.750` 5.50" TYp. NOTES: 1. BRACKET LENGTH IS 2.75". 2. THIS BRACKET IS TO BE USED WITH POST TYPE C2 OR C5, WITH OR WITHOUT SIDE PLATES PER SP3 OR SP4. 3. SEE TABLE 2 ON S7.1 FOR ATTACHMENT TO FOOTING/SLAB. 4. INSTALL 1)¢ x U¢ x J6 HDG WASHER PLATE AT ANCHORS FOR 130 MPH. 5. STEEL 7 BRACKET PER 3/S7.2 CAN BE USED IN LIEU OF THIS BRACKET. (�) ALUMINUM T-BRACKET 1=OR POSTS CZ C5 0.75" 4.Q0" ASTM A5DO GRADE B TYP 1.75" 4- a 0 HOLES 1s'0 & n HOLES, TYP EA SIDE 00 o O c Mi 0 0 0 0 PLAN Do"[ I TYP ^� 2- 4;0 HOLES FOR X-0 M.B. TYP. N epY N N 4 ELEVATION ---- NOTES: 1. THIS BRACKET IS TO BE USED WITH POST TYPE C6 WHEN FOOTING SIZE IS 24" OR SMALLER, WITH OR WITHOUT SIDE PLATES PER SP3 OR SP4. 2. BRACKET CAN ALSO BE USED WITH POST TYPE C2 OR C5 PER TABLE 2 ON S7.1 AND 2/S7.1 3. SEE TABLE 2 ON S7.1 FOR ATTACHMENT TO FOOTING/SLAB. A 1 STEEL T BRACKET FOR POST C6 3"=1'-0" 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 pp�FESSI( S 5885 LCT OF DATE SIGNED: July 06, 2018 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 SAP M� ES TM REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # 17-1071 DATE 0412511 B DRAWN BY RER CHECKED MDS IAPM0 195 V 3.0 SOLID PANEL STRUCTURES: FOUNDATION DETAILS S7.2 ATTACHED & FREESTANDING SOLID COVERS -10 PSF SNOW LOAD OR LIVE LOAD - 110 MPH - EXP. B & C B1 6.5" ROLLFORM B2 MAG BEAM B3 4" I -SEAM B4 4.5" MAG GUTTER B5 12 GA STCL"UL CHAN/NEL Bfi 7" I -BEAM ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED I FREESTANDING ATTACHED FREESTANDING MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN TRIB WIND POST FTG . POST FTG POST FTG POST FTG POST FTG POST FTG POST FTG POST FTG POST FTG POST FTG POST POST FTG POST POST FTG POST WIDTH EXP SPACING (IN) POST TYPE SPACING (IN) POST TYPE SPACING (IN) POST TYPE SPACING (IN) POST TYPE SPACING (IN) IPOST TYPE SPACING (IN) POST TYPE SPACING (IN) POST TYPE SPACING ON) POST TYPE SPACING (IN) POST TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) 110B 11'-9 18 11'-9" 25 1014, 17 9�" 25 13'-7" 19 12'4" 27 13'-3" 19 12'-2" 27 13'-0" 19 1Z-1D`' 27 C7 23'4" 22 CS 21-3 31 C7 5 C1 C7 C1 C7 C1 C7 Cl C7 C7 11DC 11'-9" 20 11'-4" 26 1D'4" i9 9'--Z 26 137 21 12'-1" 28 13'-3" 21 11'-9" 26 1Z-T 2D 11'-10" 28 23'-4" 25 20'�" 33 110 B 10'-9" 18 10'-9" 9'-9 18 8'-10'• 24 12'-9" 19 11' 8" 26 12'-Z' 19 11'-0" 26 17T' 19 11'-6" 26 22'-D" 23 C5 2D'-0" 3D C7 6 C1 C7 C7 C7 C1 C7 C1 C7 C7 C7 110 C 10'-9" 2i 27 9-9 2D 8'-6" 26 17-9 22 11'�' 28 1Z-Z 21 11'-2" 28 11'-3" 21 11'-0" 26 22 0 26 19�' 32 11D B 10'-0" 19 10'-0" 2fi 9'-3" 18 B'-0" 25 12'-Z' 20 11' 1" 26 11'-3" 20 10'-10" 26 12'-0" 2D 11'Xt' 26 20'-10" 24 19'-0" 3D C7 T C7 C7 C1 C7 C7 C7 C1 C7 C1 C7 CS 110C 1D'-0" 21 9,-B" 27 9'-3 21 8'-3" 26 12,-7' 23 1D,_9" 27 11,_3" 22 1V-7" 27 IV4, 21 10'-7 27 20'10" Z7 1B'7" 32 110 B 914, 19 9'-0" 20 B'-1 D" 19 8'-Z' 25 11'-0" 21 1 D' 7" 27 1 D'-7. 2DEC2 " 27 11'-0' 21 1 D' G' 27 20'-1" 25 CS 16=7' 31 C7 8 C1 C7 C1 C7 C2 C7 C7 C2 C7 110C 9'-0" 22 9'-1" 26 B'-10" 21 T-1 Y' 25 11'-0" 23 10'4" 27 10 7" 23 „ 27 9.4. 9,_T. Z7 20'_1" 2B 17-V 31 11 D B 8'-10" 20 B'-1 D" 27 8'-T' 19 T-9" 26 11'-1" 21 10'-2" 26 1 D'-0" 20" 27 11'-D 21 1 D'-1„ 28 19'-7' ?5 CS 1T�i 32 C7 9 C 1 C7 C1 C7 C2 C7 Cl C7 C2 C7 11 D C 8'-1 D 22 8'-7" 26 8' 7" 22 T T 26 11'-1" 24 10'-0" 27 1 D'-0" 23 27 5-2 22 9'-0 27 1 g,_Z• 28 17, 1„ 32 27 8'-3" 20 T-7' 26 1 D'-0" 22 9'-10" 2B 9'-0 212B 1 D'-0" 21 9'-9" 28 18 3 26 C5 16-1 D 32 C8 10' Cl C7 C7 C7 C2 C7 C7 C2 C7 11DC 8 G 23 B'-1" 27 8-3" 22 T4" 27 10'6 24 9'-7 28 9'-0' 23 ' 28 8-9 23 B'-T' 27 18'-3" 29 1fi�' 32 110 B 6'-1" 21 8'-1" 27 8 D" 2D T q" 27 10'-0 22 9'-T' 29 94. 21 28 9'-10" 22 9'-0' 29 17'-0" 25 i6�" 33 11' CZ C7 C1 C7 C2 C7 C7 CZ C7 C5 110 C 8'-1" 23 7-9" 2B 8'•D" 23 T-7 28 10'-0" 25 9'-3" 28 9'-1" 24 28 B'-" 23 8' 2" 28 17'-0" 29 16-0 33110B 7'-B" 21 7'-8" 2B T-T' 21 T-2' 27 9'T' 22 9'-3" 29 B' 8" 21" 29 9'-0"22 9'-Z' 29 6-8 27 C5 16-0" 3412' CB C2 C7 CZ C7 C7 C7 C2 C7 110C 7,-0 24 7,-0' 28 T_7,23 T-D" 28 9'-T' 25 V-1.. 29 6-6124" 28 B-0" 23 7'-1D" 2J 16'-B" 3D 15'T' 33 $7 7"I-BEAMW/ "C" INSERT 88 7"I-BEAMW/ "C" INSERT BS DBL 2 x 6.5 x 0.042 B10 DEL 2 x 6.5 x 0.032 $11 3x8x0.042 B12 DBL 3x8x0.042 (1) (2) ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN TRIB WIND POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG pD5T POST FTG POST POST FTG PST POST FTG POST WIDTH EXP SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (ill) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING ON) TYPE SPACING (IN) TYPE (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) 110 B 25'-9" 23 24'-0" 32 C7 29'-' 24 25-10" 33 C8 16'-0" 2D 16'-0" 29 13'-7 19 13'-2" 27 13'A 18 13'-0" 27 19'-3" C2 19-3" 30 C7 5 C5 C5 C1 C7 C1 C7 Cl C7 11DC 26 23'-0" 34 CB 29'-6" 27 26-2" 35 C9 16'-0" 22 15-3" 30 12'-7' 21 12'3" 29 1Z-1, 21 12'-7 29 18-1" 1T-0 31 110 B 25-3" 24 23'-D 31 Cl 2T-9" 25 25'-3' 32 C7 14' T' 20 14' 7" 2B 12'-1" 19 12'-1" 27 17 19 12'-6" 27 C7 17 7" C2 17' T' 29 C7 6 C5 CS Cl C7 Cl C7 C1 11 D C 25'-3" 27 22 - 33 CB 2T-9" 28 24W" 34 C8 14' T' 23 14'-0" 29 11' fi 21 11'-2" 28 11'-9" 21 11' 6 28 16-T k22 16-1" 31 110E 24'-D" 25 21'-9" 32 C7 26'�" 26 24'-O" 32 13'-6" 21 13'fi" 28 11'-Z' 20 1V-2" 27 11'7" 20 11'7 27 C7 W-3" C2 163' 29T C5 CS CB C2 C7 C1 C7 C1 110C 24'-0 28 21,_3„ 33 CS 28'-0" 28 ZT4„ 13 23 13,-0, 29 10,-0„ 22 10'-0" 27 10'-10 22 1D 27 15'_3 15XPC7 110B 23--D" 26 20'-10" 32 26-T 27 23'-0" 33 12'-0" 21 12-0" 28 10' i 20 10'6 27 1D-1 20 10-1D" 27 15'•3 15-3" 3D C7 6 CS C8 C5 CB C2 C7 C1 C7 Cl C7 G' 110 C 23'-0" 29 20-3" 32 2S-3" 30 2Z-0" 33 17-el 24 1Z-7 28 1941 22 9'-9" 27 10' Z' 22 10'-0" 27 14'-4" 25 14'-[Y 29 110B 22'4, 27 2T-1" 33 24'-3" 27 22'-1" 34 C8 12'-0" 22 12'-0" 29 9'-10" 21 C2 V-10" 27 1D'-Z 21 C2 1D'-7 27 14'-4" 23 C5 14 9' 3D C7 9 CS C8 CS C2 C7 C7 C7 110 C 22'-1" 3p 19-7" 33 2N-3" 31 21'T 34 C9 iZ-0" 24 11'-6" 29 5-0" 23 C1 9'-2' 27 9'-B" 23 Cl 5-4-27 13'-T' 25 13=Z' 3D 110E 21'4" 27 19'-0" 34 23'-6" 28 21'-0" 35 1V4. 22 11'-4" 29 9'�" 21 914" 28 9'-Y' 21 9'-Z" 28 TT-8" 24 C5 13'-0" 31 C7 1D' C5 CB CS C9 C2 C7 CZ C7 C2 C7 110C 21'-4" 31 18-T0" 33 23'-F 32 2D,-5 34 11'4 25 1D'-10" 29 9 0 Z3 B'-9' 27 9-2" 23 8'-5' 27 12'-10" 26 12 11 D B 20'-8" 28 18'-9" 34 27-9" 29 20'-8" 35 10'-10" 22 10'-10" 30 9'-0" 21 9-0 28 8'-4" 21 B'-0" 28 13'-1" 24 13-1" 31 C7 11' C5 CB C5 C9 C5 C7 C2 C7 C2 C7 CS 110C 20'-0' 31 18-3" 34 22-9" 32 2U-2 35 iD'-10" 25 10'�" 29 8'7" Z3 B�" Z8 B'-4" 23 T-0" 28 12.3" 26 17-V' 3D 11 D B 2V-1" 28 18'-T 35 22-1" 29 20'-1" 36 10'-4" 23 1 D'�" 30 8'T' 21 6' T' 28 7'-B" 21 T-8" 28 C7 12'0 24 C5 12'' ' 31 C7 12' C5 C9 C5 CID C5 C7 C2 C7 C2 11DC 2D-1" 32 iT-9" 35 22-1" 33 197" 35 1D 4" 26 10'-0" 30 6-Z 23 8'-0 26 7'-B" 23 T-1" 28 11'-9' 27 11'�' 31 B13 3x8x0.042W/ 14 GA STL INSERT B14 3x8x0.042BEAM WI 12 GA STL INSERT B15 DBL 3 x 8 x 0.042 W/ DBL 14 GA STL INSERT B18 DBL 3 x 8 x 0.042 W/ DBL 12 GA STL INSERT ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING TRIB WIDTH WIND EXP MAX POST SPACING (SPAN) FTG (IN) , MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG ON) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG ON) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE 5 110 B 18'-0" 21 C2 18'-4" 30 C7 2D'-1" 21 C2 20'-1" 30 C7 25'-1 D" 23 CS 2.5 10" 32 CB 26'-4" 24 C5 27'-6" 35 010 110 C 18'4' 23 1T-0" 31 2D'-1" 24 19-4, 32 26-17' 26 24'-10" 34 26'-0" 27 27-(r 37 8 110 B 16'-9" 21 C2 16'-9" 29 C7 18'.4" 22 C2 16-4" 30 C7 23'-0" 24 CS 23'-8" 32 CB 25'-10" 25 C5 25-1 D" 34 C10 110C 16'-9" 24 16' Z 31 16,4{" 25 17'-0" 31 23-0 27 2Z-9" 33 25-417' 27 24'-10 36 T 110E 15 7" 22 C2 15-r 29 C7 17'-1" 22 C5 3D C7 22'-0" 24 C5 22'-0" 32 C8 24'-0" 25 C5 2V4r 34 C10 110C 15'T' 24 151-D" 30 17'-1" 25 16' 4" 31 22'-0" 27 21'A" 33 24'-0" 28 23'-1" 35 8 1108 14'-7" 22 C5 14'7" 29 C7 16-D 23 C5 16' -0" 30 C7 2T-T' 25 C5 20-7" 32 C6 22'-6" 26 CS 22'-6" 34 CID 110C 14'-T' 25 14' 1" 29 16' D" 26 15'4" 30 2D-7' 28 19_9„ 32 22fi" 29 21, 7„ 34 91 1 10 B 13'-9" 23 C5 13'-9" 30 C7 15'-1" 23 C5 15'-1" 31 C7 19'-4" 25 CS 19'4" 33 CB 21' 2" 26 C5 2V-2" 35 CID 110C 13'-9" 26 13'-3" 30 15-1" 26 14'�' 3D 19'�" 29 18' 7" 32 21' 2' 29 204„ 35 10' 1108 13'-1" 23 CS 13-1" 30 C7 14'-3" 24 CS 14'-3" 31 C7 18'4" 26 C5 16'.4' 33 CB 20'-1" 27 C5 2V-1" 35 C10 110C 13'-1" 26 1ZT' 30 14'-3" 27 13'-9" 31 18'-0" 29 1T-8" 33 20'-1" 30 19'�" 35 11' 11 D B 12 24 C5 1 Z-6" 31 C7 13'-B 24 C5 13'-0" 31 C7 17 T' 2S C5 1 T-7" 34 C8 19-Z 27 CS 19'-7 36 C10 110 C 12' G' 26 1Z-0" 3D 13'-6" 27 13'-1" 31 17'T' 3D 16'-10" 33 19'-Z' 3D 18'-6" 35 12' 110 $ 1 Z-0" 24 CS 1 Z-0" 31 C7 13 -1" 25 CS I VA" 32 C7 16-9 27 CS 16-9" 34 C9 16 �° 28 C5 18'-0" 36 C10 110 C 12-D' 27 11-0" 31 13'-1" 28 12-T' 32 16'-9" 3D 16' Z' 34 18' 4" 31 17'-8" 36 NOTES: 1 -WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE (RESIDENTIAL APPLICATIONS ONLY), THE MAXIMUM POST SPACING IS THE LOWEST OF THE "MAX POST SPACING (SPAN)" SHOWN ABOVE AND THE MAXIMUM POST SPACINGS SHOWN ON DETAIL SIS7.1 2 - IT IS ACCEPTABLE TO SUBTM_rrE COLUMNS WI HIGHER NUMBERS W1 THOSE SPECIFIED IN THE TABLES SHOWN. ATTACHED 81FREESTANDING SOLID COVERS -10 PSF SNOW LOAD OR LIVE LOAD.- 120 MPH 4EXP. B 6.5" ROLLFORM S B2 MAG BEAM 4" ABEAM S B4 4.5" MAG GUTTER 65 12 GA SQ. A CHANNEL S 7 I -BEAM ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN TRIB WIND POST FTG POST POST FTG POST POST FTG POST POST FTG PAST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST WIDTH EXP SPACING (IN) n,pE SPACING (IN) TYPE SPACING (1N) TYPE SPACING (IN) .n,PE SPACING (!N) TYPE SPACING (IN) TYPE SPACING ON) .n,PE SPACING ON) TYPE SPACING (IN) n,pE SPACING ON) TYPE SPACING (IN) TYPE SPACING QM TYPE (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) 5 120 B 11'-9" 19 Cl 11'-9" 28 C7 10'-" 18 9'-0" 25 13'-T 19 12'�" 26 13-T 19 1Z-2" 28 1T-4' 19 12'-2' 28 234' 23 21-3" 33 120 C 11'-T 21 C1 C7 C1 C7 C1 C7 C1 C7 CS C8 10'-10" 29 1D-3" 20 9'-0" 28 13'-0" 22 11'-B" 30 1T-1" 22 11'f" 30 11'-2' 21 11' 0" 29 23=1" 27 2D-1" 34 B 120 E 10'-9" 19 C1 10'-9 27 C7 9'-9" 19 B'-1d' 26 12'-0" 2D 1 V-6" 28 1Z-2" 2D 11'S" 28 iz-6 20 1'I T 2B 22'-0" 24 2D1Y 32 C7 C1 C7 C1 C7 C1 C7 Cl C7 CS 120C 1d-T' 22 10'-0" 28 9'6" 21 B' 27 lZ-9' 23 11,-1- 29 12'-0" 23 1D'-1d' 29 1D'-3" 22 10'11 28 21'-9" 28 19-0" 34 C8 T 120 B 1D'-0" 20 C1 10'-0" 27 C7 9'-3" 19 8'-G' 26 12-2" 21 11=1" 27 11'-3" 20 10'-10" 27 11'7" 21 11-d` 27 20-1d' 25 19-0f' 32 C7 C1 C7 C1 C7 C1 C7 C1 C7 C5 72D C 9'-10" 22 g, 3„ 28 9, 2„ 51" 27 12'-0" 24 1o'-s" 29 11._1„ 23 1D,�„ 29 9,-0 22 �,_3 2B 20, 8„ 29 1B-0 33 C8 8 120B 9'4" 2D Cl 9'� 28 C7 8'-1 D" 20 8'-2 25 11' 8" 22 1 D'-7" 27 1 D' 7" 21 1014, 27 10'-10" 21 10'4 27 20' 1" 26 1 B 7 31 C7 C7 C2 C7 C1 C7 C1 C7 C5 CB 120 C 9 7' 23 6-8" 27 8'4" 23 7'-0'' 27 1T-F 25 10'-1" 29 10'-4" 24 9'-9" 28 B'-1d' 23 8'-0" 27 19'-9" 29 1T-3" 33 9 12DB B'-1D" 21 C1 B'-10" 27 C7 B'-T' 20 T-T 26 11'-1" 22 10-2" 28 10'-0" 21 C2 10'-0" 27 1V-3" 22 C2 10'-1" 28 19'-T 27 1T 32 C7 C7 C2 C7 C7 C7 CB 120 C 8'�" 23 B'-2. 28 8,- T-4" 28 10'-10" 25 9'-8" 2B 9'-9" 24 G7 9'-3 28 8�" 23 C1 B'-Z' 2B 18-5' 30 157" 33 1 D' 120 B B'-6" 21 C1 8'-0i" r 6-3" 21 T-7 28 1 D'-0" 23 9'-10" 2B 9`� 22 9'-0 2B 9'-9 22 C2 9' 8" 28 18'-3 27 16-1Ii' 32 C7 C1 C7 C2 C7 C2 C7 C7 C5 CB 120 C 8' 3" 24 7' 9" 28 B'-2" 24 7 T' 26 10-3" 26 9'4, 28 9'-3" 25 8'-9' 26 8'-0 24 Cl T-9" 28 1T-1 V' 31 1G 1" 32 lit" 120 B B'-1" 21 C1 8'-1" 27 C7 B'-0" 21 T-0" 27 10'-0" 23 9'-7" 29 9-1" 22 9'-1.. 28 9'-T 22 C2 9'3 28 17'�" 27 16'-4 33 Cl C7 C2 C7 C2 C7 C7 C5 12D C T-1 d' 24 T 6" 29 T-9" 24 T 0 29 9'-9" 9-1" 29 B-10" 25 8' 4 29 T£ 24 C1 T 29 1T-1" 31 15'7" 33CB 12' 12D B T-0" 22 C2 7' 6' 26 T7 21 7'T 28 9'7" 39`-3" 126 29 B'-0" 22 B'-0"29 8'-10" 23 C2 8'-1 D" 29 16'-B" 28 16-0" 34 C2 C7 CS C7 C2 C7 C7 CS CB 120 C T-T' 25 7'-71 3d3 T 6 24 6'-9" 3D 9'�" 6 8'-9" 30 8'-0" 25 8'-1" 30 6'-1 D" 24 C1 T-2" 30 16'-0" 32 15-7" 33 B7 7"I-BEAMW/ (1) "C" INSERT 68 7"I-BEAMW/ (2) "C" INSERT DBL 2 x 6.5 x 0.042 s B10 DBL 2 x6.5 x0.032 B11 3x8xO.042 B12 DBL 3x8x0.042 ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING TRIG WIDTH WIND EXP MAX POST SPACING (SPAN) FTG (IN) MIN POST n PE MAX POST SPACING (SPAN) FTG ON) MIN POST PE MAX POST SPAGNG (SPAN) FTG ON) MIN POST T PE MAX POST SPAGNG (SPAN) FTG (1N) MIN POST T PE MAX POST SPACING (SPAN) FTG ON) MIN POST T, PE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST PE MAX POST SPACING (SPAN) FTG (IN) MIN POST n PE MAX POST SPACING (SPAN) FTG (IN) MIN POS TYPE POST FTG SPACI (IN) (SPAN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN PO POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE 5 1208 26'-9' 24 C5 244" 34 OB 29'$" 25 05 26'-1d' 35 C9 16'-0" 220 Cl 15 D" 30 C7 IT-2" 20 Cl ITT 29 C7 13'-8" 20 C1 13'-8" 29 C7 19-3" 22 C2 19-T 32 C7 120 C 26'-6" 28 23-1" 36 C9 29'42" 28 25-4" 36 C11 14'-10" 22 14-7" 31 1T T' 27 1T-3.. 30 11'-8 21 11'-0 3D 16'-0°' 24 C1 1VA 32 1420 5-3 25 C5 23'-0" 33 CB 27-9" 26 25' T 34 C8 14' 7" 20 C1 14-T' 29 C7 12'-1" 20 C1 12'-1" 28 C7 12'�" 20 Ci 12 26 C7 17'T' 23 1T7" 31 C7 4'-10" 29 21'-9" 35 C9 27'-W 30 2T-1T 36 C11 13' J" 23 13'�" 31 11`-0 71 11'2" 29 1d�" Z2 1D'6 29 15-1" 25 74'-0 32 4'-U' 26 C5 21'-9" 33 CB 26'-0" 27 24'-T 34 C8 13'-0" 21 C2 13'� 29 C7 11' 2" 21 C1 11'-2" 28 C7 1T-T' 21 C1 11-7" 28 C7 1S' T 23 16-3" 3D C7 3'-B" 3D 20'-0 94 CS 26-1" 31 22'-9" 35 C9 12'-B" 23 12.4" 3D 1D'-0' 23 1D'4" 2B 10'-0" 29 9'6" 26 1d'-0" 25 13-8" 31 3'-D 2'-V' 27 31 C5 20'-10" 32 CB 25'-3" 2B 23'-0" 33 C8 7Z8" 21 C2 12'-8" 2B C7 10'-0" 21 C1 1D' 27 C7 10'-10" 27 C1 1 - " 27 1" C7 75'-3" 24 C5 15'�" 30 C7 19'-B" 34 25'-D"' 32 21'-0" 35 C9 11-10" 24 11-7" 30 1D-T 23 9'-9" 28 9, 3„ 23 13'-1" Z6 C2 12t- 30 1'-9" 32 CS 79'-0 34 CB 24'-0 33 CS C2 C7 C7 C7 C5 C7 21'-0 35 C9 11'2" 11'-D" 29 9-0" 23 C1 9-T' 26 B'-9" 23 Cl 6-7" 28 12-0" 26 1Z-1„ 3D 1',4" 1'-1" 28 32 C5 19'-0" 34 C6 23'-0 29 21'-0" 35 C9 11 �" C2 11'-4" 29 C7 9'-0" 22 C2 9-4' 2B C7 Y T 22 C2 Y-T 2B C7 13'-8" 25 C5 13 8" 31 1 F-4" 33 C9 23' 7' 33 20'-Z' 34 1 D' 8" F25 10'�" 29 9'-0" 24 C1 B'-9" 28 8'-0"24 C1 7'-9 28 11' 8" 27 11$' g0C7 12DB 20'8" 29 C5 1B'-9" 34 C9 22'-9" 30 20'-V 35 C9 10'-1T C5 1D-10" 3D C7 9'-d' 22 C2 9'-0' 2B C7 6-0" 22 C2 B'4" 26 C7 13'-1" 25 C5 137" 3111'120 C 20'4' 33 1T-7 34 22'6" 34 19'T' 35 CID 10'-T 9'-10" 29 B'-7" 24 B'-0" 29 B'-0" 24 7'-1" 29 11'-2' 27 17-0" 312DB20'-7" 12' 3D C5 1-3" 35 C9 22'-7" 312d-1" C5 36 CID 1D'-0" C5 1d�" 3D C7 8'-T' 22 C2 8'T 2B C7 7� 22 C2 7'8 2B C7 1T 25 C5 1T-0 31 CB 120C 19'-10" 34 1T-3 34 21'-1d' 35 19'-1" 95 9,9„ 28 9`6" 3D 8'-2' 24 B'-0 30 T-0 24 6T 30 1D�„ 27 10'� 30 B13 3x8x0.042W/ 3 x 8 x 0.042 BEAM W/ DBL 3 x 8 x 0.042 W/ DBL 3 x 8 x 0.042 W/ 14 GA STL INSERT $i4 12 GA STL INSERT B15 DBL 14 GA STL INSERT B1S DBL 12 GA STL INSERT ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN TRIB WIND POST FTG POST POST FTG POST POST FTG PAST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST WIDTH EXP SPACING (!N) TYPE SPACING (1N) TYPE SPACING (IN) TYPE SPACING ON) �,pE SPACING (IN) TYPE SPACING (!N) iYPE SPACING (IN) TYPE SPACING (IN) .n,pE (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) 6 120 B 18'74" 2Z C2 184 31 C7C8 20'-1" 22 C2 20'-1" 32 C7 25'-10" 24 2T-10" 34 08 2B'-0" 25 2T-0" 35 C9 C5 05 1Z0 C 1T�" 24 17'-0" 33 19-0 25 18'f 33 CB 24'4" 27 23'-10., 36 C11 26' 8" 28 26-1' 37 C71 6 120B 1V-9" 22 C2 16'-9" 31 C7 18 23 C2 1814, 31 C7 23'-0" 25 2N-B 33 C8 2T-10" 26 25'-10" 34 C8 C5 CS 120 C 15'-10" 25 15'-6" 32 W-4': 28 17-0 33 CB 22'-3" 28 21-9" 35 C9 24' 4" 29 23-9" C10 T 120B 15'-7" 23 CZ 15'7" 30 C7 1T-1" 23 L ' 1T-1" 31 C7 27-0" 26 C5 2Z-0" 33 24'-0" 26 24'-0" 12D C 14'-8" 26 14' 4" 31 16'-1" 26 15' 8" 32 2D'-B" 29 20' 2„ Sq CB m T, 29 CS 1 -1 C8 8. 1208 14'7" 23 C5 14'-T' 29 C7 16'-0" 24 CS 16'-0" 30 C7 2T-T' 26 C5 20'7" 32 2Z-0" 27 221-T E34 CB 120 C 13'-9" 26 13'-0" 31 15-1" 27 14'-0" 32 IVA" 29 18'-10" 34 21'-Z' 3D 2741 C9 C5 9. 120B 13'-9" 24IT-9" C5 3D C7 15'-1" 25 CS 15'-1" 31 C7 19'-4" 27 19'4 32 21'2' 27 21' Z' CB CS CB C5 12001 13'-0' 27 12'-0" 30 14'-2" 27 13-10" 31 C8 18'-T 30 1IT-10" 33 20'-0" 31 19 34 C9 1D' 120 B 13'-1" 24 CS 13'-1" 30 C7 14'-3" 25 14'-3" 31 1814, 27 18'4" 33 2D'-1" 2B 20'-1" 34 C8 CB CS CB C5 120 C 12'-0" 27 1Z-1" 3D CB 13'-G' 28 13-Z' 31 1T-4" 30 1T-D" 33 1", 31 IB'- 33 C9 11' 12D B 1 T-G' 25 C5 12-6 31 C7 131-8" 25 'I T-8" 31 17'-T' 28 17' 7" 33 19-2" 28 CB C5 CB CS C9 120C 11'-9" 2B 11'6 30 C8 12'-1d' 2B 1Z-T' 31 16'-7" 31 16'-2" 33 1B'-1" 32 1T-0 34 L120 12120 B 1T-d' 25 C5 12'-T 31 CB 13'-1" 26 13'-1" 32 CB 16-9 2B 16-9" 34 CB C5 CS C9 C 11'-3" 2B 11'-1" 3D 12-0" 29 12'-1'' 32 I5-10" 31 15'-0" 33 C9 iT�" 32 1T-0" 34 NOTES: 1 -WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE (RESIDENTIALAPPLICATIONS ONLY), THE MAXIMUM POST SPACING IS THE LOWEST OF THE "MAX POST SPACING (SPAN)" SHOWN ABOVE AND THE MAXIMUM POST SPACINGS SHOWN ON DETAIL 8/S7.1 2 - IT IS ACCEPTABLE TO SUBTITUTE COLUMNS W/ HIGHER NUMBERS W/ THOSE SPECIFIED IN THE TABLES SHOWN. ATTACHED & FREESTANDING SOLID COVERS -10 PSF SNOW LOAD OR LIVE LOAD -130 MPH - EXP. B & C 6.5" ROLLFORM S B2 MAG BEAM B3 4" I -BEAM 4.5" MAG GUTTER 85 12 GA STLALUM CHAN/NEL 86 7" I -BEAM ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING TB 'WIDTH WIND EXP MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG ON) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG ON) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG ON) MIN POST TYPE 5 130 B 11'-9" 20 C1 11' 7" 29 C7 1 D'�" 19 Ct 9'.31 28 C7 13'7 21 Ct 12'-Z' 30 C7 13'-3" 21 C1 12'-0" 29 C7 12'-8" 20 Cl 12'-0" 29 C7 2314. 25 20'-10" 34 C8 130C 11'-Z' 22 10'-8" 30 10'-0" 21 B'�" 29 13=1" 23 11'4" 31 12'-7" 23 11'-Z' 31 10,-3" 22 1D'-1" 3D 22'4' 29 19'-7' 36 C10 6, 113081 10'-9 2D Ct 1 D' 7" 28 C7 9'-9" 20 Cl 8'-9" 27 C7 12-9" 22 Cl 11,-6" 29 C7 12'-Z' 21 Cl 11'-3" 29 C7 11'-4" 21 C7 1 V-3" 29 C7 22'-G' 28 CS 19 e, 34 CB 1300 10'-Z' 23 9'7" 30 9'S" 22 8'-2 28 12-4" 24 1D'-B' 3D 11'�' 24 1D'-7" 30 94' i2 9'-7' 29 21'-2' 29 16'4" 35 C9 7 130 B 10'-0' 21 Cl 9'-9" 28 C7 9'-3" 20 Cl 8'4" 27 C7 12'-2" 22 C1 1 D'-10" 29 C7 11'-3" 22 Cl 10.8" 29 C7 1 D'7' 21 Ct 19-T' 28 C7 2D'-1 D" 27 C5 18' 9" 33 CB 130C 9'S' 23 8'-1D" 29 9'-0" 23 T-9 28 ill-r 25 C2 1U'-2' 3D 10'-0"' 24 1D'-D" 30 8'-0 23 F.T. 29 2D'-2' 30 17.-V 35 C9 8, 1305 9'4" 21 Ct 9' 2' 27 C7 8'-10" 21 Ct 8' 0 26 C7 11'�" 23 C2 1D'� 28 C7 10'-T' 22 Cl 1U-3" 2B C7 10'-0" 22 Ct 9'-10" 2B C7 20'•1" 27 C5 1B-0 33 CB 13D C B'-10 24 B'-3" 29 8' 7" 24 7_5" 28 11 1" 25 9'-9" 30 10'-0" 25 9'-4" 29 B'-2' 23 B'-0" 28 19'-2' 31 16'-9" 3q 9 130 B B'-10 22 Ct B'� 27 C7 $'-7" 71 Ct 7'�!" 27 C7 11'-1" 23 C2 1D'-1" 2B C7 10'-U' 23 Cl 9'-9" 28 C7 9'-4" 22 Ct 9-0" 28 C7 19'-Z' 26 C5 17-0" 32 CB 130 C 8'�" 24 7'-10" 29 B'-3" 24 7'-Z' 29 10'-6" 26 9'4" 29 9' 4" 25 C2 BAT 29 7'-6" 24 7'-7' 29 18'-1" 31 16'-1" 34 1D' 130E 8' i 22 Cl B'-3" 2B C7 B'-3" 22 Ct T� 2B C7 10'-0" 24 C2 9'•B 28 C7 91-61, 23 C2 9'-3" 28 C7 8'-10' 23 C1 B'-10" 26 C7 18'-3" 29 CS 16$' 32 CB 13U C 8'-0' 25 7 &' 3D 7-10" 25 7'-0' 3U 9'-10" 27 9'-1" 3D 8-0 25 B'-1" 30 7'-0' 24 7'-Z' 3D 1T-Z' 32 15'7" 34 11' 130 B B'-1" 23 Cl 7'-1D" 29 C7 8'-0" 23 Cl 7'-0" 29 C7 10'-0" 24 C2 9'4" 29 C7 9-7" C2 8'-10" 29 C7 B'� 23 C2 $'-0" 29 C716'4" 1T�" 29 C515'-1" 16'7' 33 CB 13D C 7-7" 25 C2 7'-27 31 T-6" 25 C2 6'-9" 31 9' 6 27 C5 $'-9" 31 7 9" 7'4' 31 6'-0 24 C1 6'-1D" 31 33 33C913DBT 12' B 23 C2 7'-7' 29 C7 7'-7" 23 C2 T-1" 29 C7 9'-T' 25 C5 9'-2' 29 C7 B' 8" ��25 C2 8'S"29 C7 8'-2' 23 C2 B'-1" 29 C7 16-8 3U C5 15 33 CB 130 C T-7" 25 6'-9' 31 7'-1"25 6' T' 31 9=1" 2B B'-0 31 7'-1" 6'-9" 31 5'-9 24 C7 6 7 31 15'-9" 33 14'�" 33 C9 B7 7"I-BEAMW/ (1) "C" INSERT 68 7"I-BEAMW/ (2) "C" INSERT DBL 2 x 6.5 x 0.042 s 610 DBL2x6.5x0.032 811 3x8x0.042 612 DBL3x8x0.042 ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN TRIB WIND POST FTG POST POST FTG POST POST FTG (POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST WIDTH EXP SPACING pN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING ON) TYPE (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) S 130E 26-5` 26 24'-0" 35 C9 29'fii" 27 264' 36 16-0" 22 15'-T' 32 13'-Z' 20 13'-2" 27 'IT-1" 20 13'-0" 27 1814" 23 C2 18'3' 33 Cfi C5 C5 C71 Ct C7 Cl C7 Cl C7 130C 25'-9' 29 22'-0" 87 Cit 28'6" 30 24'-0" 38 13'-0 24 13'�" 32 12'7 22 12.3' 29 10'-9" 22 1D'7" 29 15=1" 24 Cl 14Lr 33 6 130 B 25'-3" 27 22 7" 35 C9 2T-9" 28 24'-10' 36 C9 14'-7" 22 14'-3" 31 12'-1" 21 12'-1" 27 12'- 21 71' 10' 27 16'-9" 24 C2 1G 9" 32 C7 C5 CS Cl C7 Ct C7 01 C7 130C 30 21'-1" 37 C71 26'-9" 31 23'3 37 C71 127" 24 12'-3" 32 11'6 23 1V-7 28 7-IT 23 9'-0" 28 13'-1D" 25 13'fii 32 T 130 25 21'-6" 34 CB 26-4' 29 23'�" 35 C9 13'-0" 23 13'-Z' 30 11'-2 22 11'-2" 27 11'-1" 22 11-1" 27 15' 7 24 C2 15'-0 31 07 C5 CS C2 C7 Cl C7 Ct C7 130 31 20-1" 3S Ci i 25'-0" 32 22'-1" 37 C11 11'-" 25 11'�" 31 10'-0" 23 10'�" 27 9'-2 23 9'-0 27 12'-9 26 12, 7 • 130 B 23'-0' 29 20' 7" 34 C8 25'-3" 3D 22�" 35 C9 12'-0" 24 12'4" 30 1D'-0 22 10'� 27 10 22 10 27 14'-7" 25 C5 14'� 31 07 8. C5 C5 C2 C7 Cl C7 Ct C7 130 C 22'-1" 32 19 2" 38 C9 24'4" 33 21-2 37 C11 10=10' 26 10'-6' 30 10'-0 24 9'-0" 27 8'7 24 B'-0 27 12'-0' 26 C2 11=9 31 9 130 B 22'-1" 29 19'-9" 34 C8 24'-3" 30 21' 9" 34 C9 17-7 24 11'-8" 29 9'-10" 23 C2 9'-10" 27 9'-5' 23 C2 9'-0" 27 13'-9 25 1y-W 30 CO CS CS C2 C7 C7 C7 CS 130 C 21'-a 33 18'-6" 35 C9 23'-0" 34 20'-4" 36 C11 10'-3" 26 1D=1" 30 9'4' 24 Cl 9' 2" 27 8'-1" 24 C7 T-10" 27 11'," 27 11'-1" 31 C7 10' 130 B 21'-4" 30 19'-1" 34 C8 23'-6' 31 21' 1" 34 C9 11'4' 25 11'-1" 29 9'-4" 23 9'A" 2B 9'-2' 23 B'-0" 28 131•11, 26 13'-0" 30 CS C5 C5 C2 C7 C2 C7 C2 C7 C5 130 C 20'-7' 34 1T-10" 35 C9 22'-6" 35 19'-0" 36 C70 9'-9" 27 9'-T' 30 9'-0" 25 8'-4" 27 7'�" 25 7'-Z 27 10'-9' 27 10'-7" 30 C7 11' 130E 20'$" 31 j 18'-0" 34 C9 2Z-9" 32 20'W 35 C9 10=10" T.5 1Y-7' 29 9'-D" 23 9'-0" 26 814" 23 6'-0" 26 12'S 26 C5 12°-0 31 CB C5 C5 C5 C7 C2 C7 C2 C7 130 C 19'AV. 35 17--3" 35 C10 22'-0" 35 19-1" 36 C10 9'-4" 27 9'-2' 31 B'-7' 25 8'-D" 2B 74 25 7_- 2B 10'3" 2B 10-7" 31 12' 130 B 20'-1" 31 1 18'-0" 35 C9 22'-1'• 32 19'-0" 38 10` 25 10'-2' 3D CB 8'-7 23 B' 7" 28 T-8" 23 7'4" 28 12--0' 27 C5 11'-1Ir 31 CB CS CS CIO CS C2 C7 C2 C7 130C 19'-3" 35 1V-9" 34 C10 21'-3" 37 18,4, 35 V-9, 27 B'-9" 31 C7 B'-2' 25 T-4" 28 6'-10' 25 6'-0" 2B 9'-1D" 28 9,-8 31 B13 14 GA STL INSERT B14 312 GA STL INSERT V/ B15 DEL 14 GA STL INSERTB16 DB L12 GA STL INSERT ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING TRIG WIDTH WIND EXP MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTC, (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (III MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE 5. 130 B 18'-4" 23 C2 18'-0" 33 C8 18'-4" 24 C2 19'-8" 34 C8 25'-1D" 26 C5 25'-3" 36 CID 28'-0" 26 CS 27-3" 37 C11 130 C 16-0' 25 Cl 15'7" 34 174' 26 1T-1" 35 C9 22'-4" 28 21'-1D" 37 C11 24-6 29 29 24,-0„ 38 61 130 B 16'-9' 24 C2 16'-0" 32 C7 18'4" 24 C2 18,-(r 33 C8 23'-V 26 C5 23'-1" 35 C9 25'-10" 27 C5 25'-3 36 C10 130 C 14'-7" 25 14'-3" 33 C6 15'-10" 26 15=T' 34 20'-6" 29 20'-1" 36 C11 22'�" 30 21'-10' 37 C11 7 130 8 15'-7' 24 C2 15'-3" 31 C7 17-1" 25 C5 16 32 C7 2T-0" 27 C5 21' & 34 CB 24' D 2B C5 23' 6" 35 C9 13D C 13'-0 26 13'-2" 32 14'-9' 27 14'fii 33 CB 19'-0" 29 18'-7' 35 C9 20'-0" 30 20-3' 36 C11 B' 130 8 74'-7' 25 C5 14'-0" 31 C7 16-0" 25 C5 15' 7' 32 C8 20 7" 26 C5 2D'-1" 34 C8 22' 29 C5 22-0" 35 C9 130C 12'-8' 27 C2 1Z-4" 32 13'-10" 28 13'-0" 32 17'-9" 3D 17'4' 35 C9 19'-W 31 19-0„ 35 9. 130 B 73'-9' 23 C5 13'-6" 30 CB 15'-1" 26 CS W-6'' 31 C6 " 28 C5 19'-D" 33 CB 21'2' 29 CS 20' 6" 34 CB 130C 12'-0' 27 11'�" 31 C7 13'-1" 28 124„ 32 31 16 4„ 34 16'-0" 32 18'-D" 35 C9 10' 13111 1IT-1" 26 CS 12'-0" 30 CB W-3" 26 CS 14'-0" 31 CB" 29 CS 18'-0" 33 C8 20'-1" 3D CS 19'-8 34 C8 130 C 11'-4" 28 11' 7 31 12.1 29 12'A" 31 01T"'I' 31 15'-T' 34 17'-0" 32 17'-1" 35 C9 13D E i z-6, 26 C5 12-2" 31 C8 13' 8 27 CS 13'-" 31 C8" 29 C5 17-2" 33 C8 19'-2" 301B'-9" CS 3411' C9 130C 1U-10" 28 107" 31 11'-10' 29 11'T' 31 32 W-10' 33 16-T' 33 16,_3„7 12' 13D B 12' fY' 27 C5 11-6" 31 C8 13'-1" 27 CS 17 9 32 C8 " 3D C5 16 6 33 C9 16'A- 31 CS 16'-D" 35 C9 130 C 10'-4" 29 10'-1" 31 11'-4" 30 11-1" 31 14' 7" 32 14'-3" 33 15'-10" 33 15'-7 34 NOTES: 1 -WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE (RESIDENTIAL APPLICATIONS ONLY), THE MAXIMUM POST SPACING IS THE LOWEST OF THE "MAX POST SPACING (SPAN)" SHOWN ABOVE AND THE MAXIMUM POST SPACINGS SHOWN ON DETAIL 8/57.1 2 - IT IS ACCEPTABLE TO SUBTMJTE COLUMNS W/ HIGHER NUMBERS W/ THOSE SPECIFIED IN THE TABLES SHOWN, ATTACHED & FREESTANDING LATTICE COVERS -10 PSF SNOW LOAD OR LIVE LOAD -130 MPH - EXP. B & C B5 3"SQ.ALUM 12 GA STL"U" CHANNEL W/ $9 DBL2x6.5x0.042 B11 3x8x0.042 Bi0 DBL2x6.5x0.032 812 DBL3x8x0.042 g1S 3x8x0.042W1 14 GA STL INSERT ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING TRIB WIND MAX POST FTG. MIN. POST MAX POST FTG. MIN. POST MAX POST IFTG. MIN. MAX POST MIN. IFTG. MAX POST FTG. MIN. MAX POST MIN. FTG. MAX POST IFTG. MIN. MAX POST MIN. F7G. MAX POST MIN. MAX POST MIN. MAX MIN. MAX MIN. WIDTH EXP. SPACING (IN-) TYPE SPACING ON-) TYPE SPACING (IN.) POST TYPE SPACING POST (1N.) TYPE SPACING (IN.) POST TYPE SPACING !POST ON.) TYPE SPACING (1N,) POS7 TYPE SPACING (IN.) POSTJ TYPE SPACING I,-TG. POST pN) ITYPE SPACING FTG. (IN.) (POST ,TYPE POST SPACING IFTG. (IN.) POST POST SPACING IFTG. {IN.) POST (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) TYPE (SPAN) TYPE 5 130 B 16 8 17 C1 14-7" 32 C9 14--1I1' 16 Cl 14'-10 31 C7 15'-4" 16 C1 15' 7' 31 1B'-0" 17 17'-0" 33 C7 21'-8" 19 21' 4" 34 CB 20'-9 1B 20� 32 CB 19 W7" 13'48' 33 14'-2' 33 C7 Cl 15-6 3q C8 2(1'-10" 21 C1 2640 36 C11 2d'4r 2T Cl 130 C 15'-0" 34 C10 14'-V 79 14-loll 19 17' 3 20 19'-1" 34 C9 6' 130 B 154' 18 C7 13v 3l C9 13'7" 17 Cl 13'-7" 31 C7 14'-1" 17 Cl 13'-10" 31 C7 16'-0" 1B 16'-7' 32 C7 19'-9' 19 IV 33 CB 18'-0" 19 C7 16'-0 32 CS 130 C 13'-9" 34 C10 13'-1" 19 13'T 19 15-loll 20 16'3" 21 C2 IT-C' 33 C9 20 13-3" 12 6 32 IT 0 32 C1 75-t" 33 C8 C2 19-1" 72 18'-3" 35 C9 T 14'-2" is Ci 12-0" 31 CB 12'T' 17 Cl 127" 30 C7 T3:7" 17 Cl 12-10 3D 15-2" 18 15'-0" 31 C7 18�" ?a 1B'-1" 33 iT-i 19 17-3 31 C7 20 12' 4" 71'-7" 31 72-1" C7 31 Cl 14'-0 33 CB 17-0' 22 C2 16'-loll 34 CB C2 17-9" 33 C10 12'-2' 20 12-T' 20 14 21 17-0_T 22 76'-2 33 C6 B 13'-3 78 cl 11-7" 30 C8 11'-9" 1B c1 11-9' 29 C7 12-3" 16 c1 12'-1" 29 14-3" 19 C1 14'-1" 31 17 20 17-0 32 C7 16'-0" 2fl 1B'2 30 C7 20 11=7" 1D-50 31 t1'-3" c7 31 C2 13'-1" 32 C7 1fi-7 23 C2 15'-loll 34 C$ 10�C 11'-loll 32 C70 11'4" 20 115 20 13'S 21 15'-10' 22 75'2 32 CB 9 12'-T' 19 Cl 11-0" 30 CB 11' 2" 18 Cl 11'-2" 29 C7 11 7' 16 Ci 11'-0" 29 13' fi' 19 13'-3" 30 18' 3" 21 16'-0" 32 C7 15'-0 20 15' 3" 31 C7 21 11-0" 103' 30 iD'-8" C7 30 C2 12-4" 32 C7 15'$" 23 CS 16-0" 33 CS C2 11'-3" 32 C9 10'-9" 21 11-2" 21 IT01- 22 15-0" 23 14'3" 32 CS 10' 12'-0 19 C2 i0'as' 30 CO 10'-7" 18 C1 70 7^ 29 C7 11'-0g2l Cl 70 9 29 12-9 20 12'T' 30 15'4" 21 15-2" 32 Cl 14'-9' 21 i4'fii' 31 9� 30 9-10 C7 30 C2 11'-9" 31 C7 1k-loll 24 C5 14-2" 33 CB CS C7 l0'-B" 21 Cl 10 4" 32 C7 10' 2" 21 10-T' 12-3 22 14'-7' 23 18-7 31 130 B 11'�" 79 9-10 30 CS 10'-1" 18 Ct 70 1' 29 C7 10'-0 Cl i0-3" 29 12-2 20 12-0" 3114'-0" 32 C$ 14-1' 21 t3-loll 32 G711'C2 22 9-3" 31 9'-0 C7 37 C2 11'-3" 31130 C7 13DC 1TJ-2" 9-1(T" 32 C9 9'-9" 27 9-10" 9" 23 i2' B 10'-10 20 C2 9-0 37 CB 9'-0" 19 C2 9'-8"299''� C7 C2 29 C7 11 20 130 C 9'-g' 22 9'fi 33 C10 9'-0" 22 9'-(T 31 T-1" 8'-3" 31 11'-3' 23 C2 10'-9' 31 C7 13'-T' 24 C5 13'-0" 3'G CB 13'-0" 24 12'-0 32 C7 3x8x0.D42BEAMW/ E4 12 GA STL INSERT DEL 3 x 8 x 0.042 W/ B15 DBL 14 GA STL INSERT DBL 3 x 8 x 0.042 W/ B16 DBL 12 GA STL INSERT ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING TRIB WIDTH WIND EXP, MAX POST SPACING (SPAN) FTG (IN.) MIN. POST TYPE MAX POST SPACING (SPAN) 17G. (IN.) MIN POST TYPE MAX POST SPACING (SPAN) FTG. ON.) MIN. POST TYPE MAX POST SPACING (SPAN) IFTG. (IN.) MIN. IPOST TYPE MAX POST SPACING (SPAN) FTG. (IN) MIN. POST TYPE MAX POST SPACING (SPAN) FTG• (IN_) MIN. POST TYPE 5 1308 22'4" 19 Cl 22'4" 35 1 C9 29'-2' 20 C2 28'-9" 37 1 1 32'-0" 21 CS 32-0 29' 4' 36 40 C11 130 C 21'-loll 21 C2 20'-}0" 36 C11 28' 7' 23 C5 26'-iG' 39 32' 0" 24 6 130B 2D,4r 19 C2 20'-0" 34 CB 26-T 21 25-3' 38 C11 29 22 CS 29'T' 26'-10" 37 39 C11 130 C 20'-0 22 19-1" 36 C9 25'-9" 24 24'-7- 3B 29'-2' 25 T 130 B 19'-2 20 C2 is, -loll 33 CS 24'-0" 22 C5 24-k' 35 C9 27'-1" 22 C5 27'-1" 24'-10" 36 38 Cl1 130 C 18' 8 23 iT4" 35 C9 23-10 25 22'-9" 37 Cl1 2T-1" 25 8' 130 8 130C 1B'-0" 1T�" 20 23 C2 17'LB" 33 C7 23'-2 22 C5 22'-9" 35 C9 25'-3" 23 CS 25'-3" 23-3 36 37 010 C11 1G7' 34 CW252 25 21-3' 37 C11 25-3" g 130 B 130 C 17'-0 16� 21 24 C5 16-B" $2 C723 C5 21'-6" 34 C8 23'-10" 23 C5 23'-10" 22'-0 35 37 C9 C11 T5'-T' 34 C26 2U-1' 36 Cll 23'-10" 26 10' 13u B 16-1"C5-loll 32 C23 CS 20'-0" 34 C6 22-B" 24 CS 22'-0" 20'-10" 35 36 C9 C17 130 C 15'-T' 24 14-10" 33 8 19'-1" 35 C9 22'-B" 27 130 B 130 C is, .. 14-loll 22 24 CS 15-2' 32 C7 23 CS 191-T 35 C9 21%8" 24 CS19'-10" 21'4' 36 36 C9 C1l t4-2" 33 18-2 35 21'8" 27 12' 130B 14'4' 22 C5 14'E" 33 CB 24 C5 1 B'-B" 35 C9 20 B" 24 C5 2"' 36 C10 130 C 14'-2' 25 13-T' 32 1T 6" 35 20" 28 19'-1" 36 C9 NOTES: 1 - WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE (RESIDENTIAL APPLICATIONS ONLY), THE MAXIMUM POST SPACING IS THE LOWEST OF THE "MAXPOST SPACING (SPAN)' SHOWN ABOVE AND THE MAXIMUM POST SPACINGS SHOWN ON DETAIL 8/1-7.1 2 - IT IS ACCEPTABLE TO SUB71TU7E COLUMNS W1 HIGHER NUMBERS WI THOSE SPECIFIED IN THE TABLES SHOWN. 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 /mac 4��}Fti55 S 5885 PF OF CAL 1F�` DATE SIGNED: July 06, 2018 OrA 7i0L. 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 FAX 949.305.1420 IAP M� NTM ES REVISIONS MARK DATE DESCRIPTION 4 STEL JOB# 17A071 DATE D412511 B DRAWN BY RER CHECKED MDS IAPM0195 V 3.0 LATTICE STRUCTURES - BEAM SPANS & FOUNDATION SIZES 10 PSF LUSL, 130 MPH L 8.10.3 ��j1Vf1111Nllrlr�, ���fl5SI��QjE'! }FES510N�( O� D0 L �j�ti 0�'SDF CONN. Lea F I Cq O�' K ..Rod.. ;,, v� 49725 yQ m �; owl . �� DUSTIN S 5885 51974r'Q R 5 EP I H K n Q- No. 32875 E WA LICENSED PROFESSIONAL ENGINEER HAWAII LICENSE %`Situ t t t 11111 er r 16508 OF p. R05�/ IDAHO LICENSE OF DUSTIN K. ROSEPINK 0 CIVIL MASSACHUSETTS LICENSE DUSTIN K. p 1 - cn ROSEPINK 1T1 — o.15 02 NEW HAMPSHIRE LICENSE _ n anevnnenen.... DUSTIN ROSEPINK wnnnn ev000aoevaaova� nn123841 , RHODE ISLAND LICENSE I TEXAS LICENSE ++',.1�11 s C514 i p I I l lryryy'" `y``;n F.� _ES_S lCti4� ''iifri _ "[DUSTIN ROSEPINKI'° iE 1 081.007404 ar '�� ILLINOIS LICENSE Qt,�� F I MI I IC l`,,•II�r DUSTIN K. ROSEPINK DJ - No, 6201065154 "r!«lllllff�5•' MICHIGAN LICENSE 2 0 : DUSTIN K. ;� = w : ROSEPINK - y'. 2:4475-1 P:;_z s ••+11111101", IOWA LICENSE ``tt 1111 r+//I Rps� ,ttttt111 t1111rrrrr :• �r� .. � jG tr hiss; • . �,¢,'-., 1 No. 187!! -•fffflliH•- DELAWARE LICENSE 1.�1f1f 11 l,f rlrrrrrr rzc `o.40= 20550 rs/ONA'1-.��` '''rr+r a n111fs�`s KANSAS LICENSE Ll ENGINEER Nam•.• 55517 - P, " r 1 1111 1 �"o,.,�iw ► Seorilf MINNESOTA LICENSE MISSISSIPPI LICENSE N CA 20460 = _ 035378 sr !Q S/0NAL frr'rf I�iC R•`+: pR � �'''+r111111111'`, T�..� DRYO NEW MEXICO LICENSE NORTH CAROLINA LICENSE NORTH DAKOTA LICENSE gTRUCT� cl �Z W No.9466229-2203 O LL O DUSTIN ROSEPIN C( le .m UTAH LICENSE •boas,, J.TI, 6' V UMN K ROSI;r Lic. No. 0402058543 ►�0 ww fib, t1a �� rr•i�+� i Oti 1d +�;' VIRGINIA LICENSE %ROFESS70� I/ -9 DUSTIN r ROSEPINK C) U) - PE-10228 3 SlSyl it TL� ALi�t}�I ASHINGTON LICENS ��s,snsnlrrr�rr v 84D4D afy7 r .''., . DNA L FLORIDA LICENSE •'•DUSTIN K.• ROSEPINK • '� * = 32350 KENTUCKY LICENSE �0 ft 1 ���p1gTL��G No. Pr-n losSO - •`� K Rom" GEORGIA LICENSE e4% OF f DUSTIN K. ROSEPINK ob PEI .d MAINE LICENSE MISSOURI LICENSE I NEBRASKA LICENSE D PROFe. �NGINiF Sia 81971PE KtI�� K. RQS�Q N K. ROSEPINK ENG114EER 1 l PEOB7174 h OREGON LICENSE I PENNSYLVANIA LICENSE 1C. ROS •���.. �'�� P E 16352�'Q YD MING WYOMING LICENSE NOTE: PROFESSIONAL STAMPS ARE SHOWN WITHOUT THE LICENSE EXPIRATION DATE. PLEASE CHECK WITH THE STATE WHERE THE PROJECT IS BUILT OR CALL 4STEL ENGINEERING FOR CURRENT LICENSE EXPIRATION DATE.