BMCH2018-0436G "�f Qazkm VOICE (760) 777-7125
78-495 CALLE TAMPICO T4t!t LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 10/24/2018
Permit Type/Subtype: MECHANICAL/ Owner:
Application Number: BMCH2O18-0436 JOSEPHINE CIARAMITARO
Property Address: 78860 GALAXY DR 78860 GALAXY DRIVE
APN: 609560007 LA QUINTA, CA 92253
Application Description: CIARAMITARO / 2-HVAC CHANGE OUT - 16SEER/80AFUE SPLIT SYSTEM
Property Zoning:
Application Valuation: $19,688.00
Applicant: Contractor:
IE INC. PREFERRED AIR CONDITIONING HEATING & PLU
32115 LA BAYA 45-311 GOLF CENTER PKWY STE A
WESTLAKE VILLAGE, CA 91362 OCT 3 0 2018 INDIO, CA 92201
GITY ORA QUINTA (760)863-0832
` FIX-1('�PUPNIT DEPART�a� Llc. No.: 1022645
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 70001 of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C20, C36 License No.. 1022645
f �
Date:( $ Contractor:_ Cam-
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
() I am exempt under Sec. B.&P.C. for this reason
Date,
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
--� I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: WESCO INSURANCE COMPANY Policy Number: WWC3342930
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Ial'�G �I 8 �' •
Date: Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above -mentioned property for inspection purposes.
Date: ID 30 14'r Signature (Applicant or Agent).<
Date: 10/24/2018
Application Number:
BMCH2018-0436
Owner:
Property Address:
78860 GALAXY DR
JOSEPHINE CIARAMITARO
APN:
609560007
78860 GALAXY DRIVE
Application Description:
CIARAMITARO / 2-HVAC CHANGE OUT - 16SEER/80AFUE SPLIT SYSTEM
LA QUINTA, CA 92253
Property Zoning:
Application Valuation:
$19,688.00
Applicant:
Contractor:
IE INC.
PREFERRED AIR CONDITIONING HEATING & PLU
32115 LA BAYA
45-311 GOLF CENTER PKWY STE A
WESTLAKE VILLAGE, CA 91362
INDIO, CA 92201
(760)863-0832
Llc. No.: 1022645
Detail: (2) HVAC CHANGE OUTS -16 SEER/80 AFUE SPLIT SYSTEMS. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. PER 2016
CALIFORNIA BUILDING CODES.
RCAC CR1a71 FFF
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HVAC CHANGEOUT- PACKAGED UNIT
101-0000-42402
0
$80.04
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HVAC CHANGEOUT - PACKAGED UNIT PC
101-0000-42600
0
$53.36
Total Paid for CHANGEOUT: $133.40
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PERMIT ISSUANCE
101-0000-42404
0
$101.40
Total Paid for PERMIT ISSUANCE: $101.40
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
- GEJ1 J h, 1)ESE RJ -
PERMIT# Tm44 2tQaiara
PLAN LOCATION:
Project Address: 78860 Galaxy Drive
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #:
Replace (2) 4 ton / 90,000 BTU complete HVAC systems
Applicant Name: Steven Schnierer
Address: 31225 La Baya Drive Suite 213
City, ST, Zip: Westlake Village, CA 91362
Telephone: 818-735-7876
Email: swschnierer@ road runner com
Valuation of Project $ 19,688.00
Contractor Name: Preferred A/C & Heating
Address: 45-311 Golf Center Parkway Suite A
City, St, Zip Indio, CA 92201
Telephone: o,,,,
New SFD Construction:
Conditioned Space SF
Garage SF
Patio/Porch SF
Email Fire Sprinklers _ SF
State Lie:1022645 City Bus Lie:
Arch/Eng Name:
Construction Type: Occupancy:
Address:
Grading:
City, St, Zip
Telephone:
Bedrooms: Stories: # Units:
Email:
State Lie: City Bus Lie:
Property Owner's Name: Ciaramitaro, Josephine
New Commercial / Tenant Improvements:
Address: 78860 Galaxy Drive
Total Building SF
City, ST, Zip La Quinta, CA 92253
Construction Type: Occupancy:
Telephone: 310-344-3619
Email:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
.krvt - ism S..�+'
OFFICE USE ONLY
#
Submittal
Req'd
Req'd
Plan Sets
Structural Calcs
Truss Calcs
Title 24 Ca1cs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
A. General Information
CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF1R-ALT-02 document for each dwelling unit.
01 Project Name
03 Project Location
05 CA City
07 1 Zip Code
09 1 Climate Zone
JOSEPHINE CIARAMITARO
78860 GALAXY DR
02 Date Prepared
04 Building Type
La Quinta 06 1 Dwelling Unit Name
92253 OS Dwelling Unit Conditioned
Floor Area (ft2)
Number of Space
15 10 Conditioning (SC) Systems in
this Dwelling Unit:
2018-10-24
Single family
JOSEPHINE CIARAMITARO
3000
7
B. Space Conditioning
(SC) System
Information
01
02
03
04 05
06
07
08
09
10
Is the SC Installing a
SC System
SC System
CFA served
system a refrigerant
Installing new SC
Installing
Installing
Installing
Identification or
Location or Area
by this SC
ducted containing
system
more than 40
entirely new
entirely new
Name
Served
System (ft2)
system? component?
components?
feet of ducts?
duct system?
SC system?
Alteration Type
System 1
Location 1
1500
Yes Yes
Yes
No
No
No
Altered space
conditioning system
System 2
Location 2
1500
Yes Yes
Yes
No
No
No
Altered space
conditioning system
C. Extension of Existing
Duct System,
Greater Than
40 Feet (Section 150.2(b)1Diib)
This section does not apply to this project.
Registration Number: 418-A020083753A-000-000-0000000-0000 Registration Date/Time: 2018-10-24 07:22:16 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2018-10-24 07:22:15
Schema Version: rev 20180426
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)1E and F)
01
02
03
04
05
06
07
08
09
10
11
12
Heating
Cooling
System
Heating
Altered
Heating
Minimum
Altered
Cooling
Minimum
Required
New or
Identification
System
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct
or Name
Type
Components
Type
Value
System Type
Components
Type
Value
Type
Duct Length
R-Value
Central gas
All new
CentrAaCl split
All new
This field or
This field or
System 1
furnace
heating
AFUE
80
cooling
SEER
16
Setback
section is not
section is not
components
components
applicable
applicable
Central gas
All new
Central split
All new
This field or
This field or
System 2
furnace
heating
AFUE
80
AC
cooling
SEER
16
Setback
section is not
section is not
components
components
applicable
applicable
Required Documentation:
CF2R-MCH-01-E - Space Conditioning Systems
- Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16)
CF2R and MR-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced
-Leakage rate compliance: <= 15 percent or <= 10 percent leakage to outside, or seal all accessible leaks.
CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH-25 is required.
Exceptions:
Duct systems registered with HERS provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements.
Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MCH-25.
-Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements.
E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)1E, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C)
This section does not apply to this project.
Registration Number: 418-A020083753A-000-000-0000000-0000 Registration Date/Time: 2018-10-24 07:22:16 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2018-10-24 07:22:15
Schema Version: rev 20180426
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-iR-ALT-HVAC) (Page 3 of 3)
Documentation Author's Declaration Statement
1.1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature'
Jo Anne Orona
Ja-Avwi.&Orona.
Company:
Signature Date:
I Permit E Raters
2018-10-24
Address:
CEA/ HERS Certification Identification (if applicable):
31225 La Baya Drive
City/State/Zip:
Phone:
Westlake Village CA 91362
1818-735-7876
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. I will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Responsible Designer Signature:
Octovio Garza
octovco-cars'a.
Company:
Date Signed:
Preferred Air Conditioning Heating & Plumbing
2018-10-24
Address:
License:
40719 Fortunato Court
1022645
City/State/Zip:
Phone:
Indio CA 92203
760-863-0832
Digitally signed by CHEERS TM. This digital signature is provided in order to secure the content of this registered
document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 418-A020083753A-000-000-0000000-0000 Registration Date/Time: 2018-10-24 07:22:16 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2018-10-24 07:22:15
Schema Version: rev 20180426