Loading...
BRES2017-0083`&ty/ 4 78-495 CALLE TAMPICO � LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED Application Number: BRES2017-0083 Property Address: 51680 AVENIDA MENDOZA APN: 773143008 Application Description: SOUTHERN INTERNATIONAL/ 1,702SF DWELLING Property Zoning: Application Valuation: $110,280.10 Applicant: D DESERT ISLES INC 41490 SPARKEY WAY OCT 31 2018 BERMUDA DUNES, CA 92203 0 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/31/2018 Owner: SOUTHERN INTERNATIONAL COMPANY INC. 41490 SPARKEY WY BERMUDA DUNES, CA 92203 Contractor: DESERT ISLES INC 41490 SPARKEY WAY BERMUDA DUNES, CA 92203 CITY OF LA QUINTA (760)345-3585 DESIGN &DEVELOPMENT DEPARTMENT Llc. No.: 737763 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C27, C53, B License No.: 737763 Date.*'- M, 26 Contracwri� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Add WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the ork for which this permit is issued. haveve and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: BENCHMARK INSURANCE COMPANY Policy Number: CST5011600 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Dzi* Apphi aM: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. Dater /—"e/�+Si;&Ah)W(ApplicantorAgent) FINANCIAL DESCRIPTION INFORMATION ACCOUNT CITY AMOUNT PLAN CHECK/PERMIT EXTENSION PROCESSING 101-0000-42600 0 $104.55 Total Paid for ADMINISTRATIVE: $104.55 DESCRIPTION ACCOUNT CITY AMOUNT HOURLY CHARGE - YES ADMINISTRATIVE STAFF 101-0000-42600 0.25 $10.00 DESCRIPTION ACCOUNT CITY AMOUNT HOURLY CHARGE -YES STRUCTURAL PLAN REVIEW ENGINEER 101-0000-42600 1.5 $142.50 Total Paid for BLDG CITY STAFF - PER HOUR: $152.50 DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $5.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $5.00 DESCRIPTION ACCOUNT CITY AMOUNT Credit Card Fee 101-0000-43505 0 $1.88 Total Paid for Credit Card Fee: $1.88 DESCRIPTION ACCOUNT CITY AMOUNT DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - LIBRARIES 253-0000-43200 0 $344.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARKS/REC 251-0000-43200 0 $2,048.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 DESCRIPTION ACCOUNT CITY AMOUNT TEMP POWER SERVICE 101-0000-42403 0 $25.33 DESCRIPTION ACCOUNT CITY AMOUNT TEMP POWER SERVICE PC 101-0000-42600 0 $17.73 Total Paid for ELECTRICAL: $43.06 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $26.52 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,OOOSF, PC 101-0000-42600 0 $10.92 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $156.04 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,OOOSF, PC 101-0000-42600 0 $51.49 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $244.97 DESCRIPTION ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $25.33 DESCRIPTION ACCOUNT CITY I AMOUNT EXHAUST HOOD 101-0000-42402 0 $12.67 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD PC 101-0000-42600 0 $5.07 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE PC 101-0000-42600 0 $25.33 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN 101-0000-42402 0 $50.68• DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN PC 101-0000-42600 0 $20.28 Total Paid for MECHANICAL: $215.36 DESCRIPTION ACCOUNT CITY AMOUNT MULTI -SPECIES RESIDENTIAL 8.1-14 UNITS - 2018 UPDATE 101-0000-20310 0 $537.00 I Total Paid for MULTI -SPECIES RESIDENTIAL: $537.00 I DESCRIPTION I ACCOUNT I QTY I AMOUNT NEW CONSTRUCTION PERMIT 101-0000-42400 0 $557.46 Total Paid for NEW CONSTRUCTION PERMIT: $557.46 DESCRIPTION ACCOUNT CITY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,000.00 DESCRIPTION ACCOUNT CITY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $40.52 Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,040.52 DESCRIPTION ACCOUNT CITY AMOUNT BACKFLOW DEVICE 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT CITY AMOUNT BACKFLOW DEVICE PC 101-0000-42600 0 $5.07 DESCRIPTION ACCOUNT CITY AMOUNT BUILDING SEWER 101-0000-42401 0 $25.33 DESCRIPTION ACCOUNT CITY AMOUNT BUILDING SEWER PC 101-0000-42600 0 $17.73 DESCRIPTION ACCOUNT QTY AMOUNT FIXTUREITRAP 101-0000-42401 0 $152.04 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $152.04 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $40.02 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $7.60 DESCRIPTION ACCOUNT CITY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT CITY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.67 Total Paid for PLUMBING FEES: $477.19 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $14.34 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $14.34 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT CITY AMOUNT SINGLE FAMILY DETACHED 224-0000-20320 0 $1,837.44 Total Paid for TUMF - RESIDENTIAL: $1,837.44 Bin # City of La Qu,inta Building a Safety Division P.O. Box 1504, 78-495 Caile Tampico La.Quinta, CA 92253 - (760) 777-7012 Oct?, Building Permit Application and Tracking Sheet Permit # t? f2 E�-S ZC n Project Address:. �, 6 Z c Owner's Name: S0�7h G' � ti i�'i N ► a►VA4 A. P. Number: / - Z 7 -- 8 Address: qp S 412 w .} Legal Description: r p City, ST, Zip: 6A '-W DUJUGJ Cyr Contractor _ 7' r� �' , Telephone: ]Kp - 7 rj 2 - O • Address: 411. 0 r f' i Project Description: City, ST, Zip: CZ4JI La J- I L1G Q z - Telephone: �60 MOW.?t State Lic. # : -19 City Lie. #; j Atch , ,'i Designer: P0,4jwi VV/ Address: c 2 fj S tl City., ST, Zip: Telephone: 126.'6 .., j 6,5"-' 1z Construction Type: _ r J Occupancy: State Lie. #: �j 20 Project type (circle one): 0a Add'n Alter Repair Demo Name of Contact Person: a % �� Sq. Ft.: 1 D Z # Stories: �ok� `� # Units: Telephone # of Contact Persor06p Z 170 ^Q YJ 2— 1 Estimated value of Project' [ APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Reed TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cities. Reviewed, ready for corrections Plan Check Deposit Truss Cities. Called Contact Person Plan Check Balance Title 24 Cales. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 214 Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up SALL H.0 A. Approval Plans resubmitted Grading IN HoUSE•r '^' Review, ready for correctionarmue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Date: 10/30/2018 La Quinta, CA 92253 No.: 18-01155-1 (760)771-8515 Owner: Southern International Company Inc Email: Address: 51-680 Avenida Mendoza City: La Quinta Type: Single Family Residential Lot # Street No. 51-680 Comments: Street Name Avenida Mendoza ,%TIED Ir Iy�z� 1; ING Ir WELL y [6 ��P1151EuCRn s 4QLAwJTAy 4 Jurisdiction: La Quinta Tract #: Sq. Feet APN Permit No. 1702 773-143-008 At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.79 X 1702 S.F. or $6,450.58 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: CC r w CastrQ Check No.: 1677906992 Bank Name/Recipient of Certificate Telephone: 760-272-0579 Funding: Residential By Scott L. Ba i I ey Superintendent Fee Collected/ Exempted by: Arianne Catano Certificate Fees Due: $6,450.58 Original Payment(sl Rec'd: $0.00 New Payment Rec'd: $6,450.58 Over/Under, $0.00 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or other payment idenr W-W to L {p e date on which the building or installation permit for this project is issued, or from the date on which those amount tot ds ) rherpublic entity authorized to collect them on the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. OCT 3 0 2018 CITY OF LA QUINTA COMMUNITY DEVELOPMENT RECORDING REQUESTED BY: Orange Coast Title Company AND WHEN RECORDED MAIL TO: Southern International Company, Inc 41490 Sparkey Way Bermuda Dunes, CA 92203 DOC # 2016-0436729 10/05/2016 02:27 PM Fees: $24.00 Page 1 of 4 Recorded in Official Records County of Riverside Peter Aldana Assessor -County Clerk -Recorder "'This document was electronically submitted to the County of Riverside for recording— Receipted by: ALYCIA #778 THIS SPACE FOR RECORDER'S USE ONLY Title Order No.: 210-1809207-10 Escrow No.: 004538-LM AP#: 773-143-008-9 GRANT DEED TPA-: Bpd —0�1/ THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX is $55 00 [X] computed on full value of property conveyed, or [ ] computed on full value less value of liens or encumbrances remaining at time of sale. ( ] Unincorporated area [X] City of La Quinta AND FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Raul Velasco, and Rocio Velasco, husband and wife as Joint Tenants hereby GRANT(s) to; Southern International Company, Inc, a California Corporation the real property in the City of La Quinta, County of Riverside, State of California, described as: LEGAL DESCRIPTION ATTACHED HERETO AS EXHIBIT "A" AND MADE A PART HEREOF Also Known as: Vacant Landa - APN# 773-143-008-9, La Quinta, CA 92253 DATED: September 21, 2016 Signature Page attached hereto and made a part hereof REC ;,m:n MAIL TAX STATEMENTS TO PARTY SHOWN BELOW; IF NO PARTY SHOWN, MAIL AS SHOWN ABOVE: O C T SO 2018 CITi` OF I r:% Qi-1111TA Ct?f'I!ll'olytxv,,ri 0rv�l �PMENT RECORDING REQUESTED BY: Orange Coast Title Company AND WHEN RECORDED MAIL TO: Southern International Company, Inc 41490 Sparkey Way Bermuda Dunes, CA 92203 THIS SPACE FOR RECORDER'S USE ONLY: Title Order No.: 210-1809207-10 Escrow No.: 004538-LM AP#: 773-143-008-9 GRANT DEED TPA-' b'ZD -OP-1 THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX is $55.00 [X] computed on full value of property conveyed, or [ ] computed on full value less value of liens or encumbrances remaining at time of sale. [ ] Unincorporated area [X] City of La Quinta AND FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Raul Velasco, and Rocio Velasco, husband and wife as Joint Tenants hereby GRANT(s) to: Southern International Company, Inc, a California Corporation the real property in the City of La Quinta, County of Riverside, State of California, described as. LEGAL DESCRIPTION ATTACHED HERETO AS EXHIBIT "A" AND MADE A PART HEREOF Also Known as: Vacant Landa - APN# 773-143-008-9, La Quinta, CA 92253 DATED: September 21, 2016 Signature Page attached hereto and made a part hereof MAIL TAX STATEMENTS TO PARTY SHOWN BELOW; IF NO PARTY SHOWN, MAIL AS SHOWN ABOVE: Title Order No.: 210-1809207-10 Escrow No.: 004538-LM AP#: 773-143-008-9 SIGNATURE PAGE Title of Document: GRANT DEED Date of Document: September 21, 2016 Raul Velasco OC6 Rocio Velasco ACKNOWLEDGMENT A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. STATE OF CALIFORNIA COUNTY OF c- (- ;s ci-t) On (-' : i ._ 'n a7 I ) before m I.,, L-L L- A Notary Public personally appeared C7 3 -s_ 0 who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) } are subscribed to the within instrument and acknowledged to me that h6/�F e/they executed the same in ysl,�6r/their authorized capacity(ies), and that by h(S"rltheir signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. L. M. DE LA LUZ Commission # 2059240 I r. Signature ( l i-` Notary Public -California i z 9 Riverside County a (Seal) My Comm. Expires Feb 27, 2018 Title Order No.: 210-1809207-10 Escrow No.: 004538-LM AP#: 773-143-008-9 SIGNATURE PAGE Title of Document: GRANT DEED Date of Document: September 21, 2016 Raul Velasco- 1� Roclo Velasco C rlFl� T1ON Under the provisions of Government Code 27361.71 certify under the penalty that the following is a true copy of illegible wording found in the attached document, Date: Signature: Print Name: 1�asmin Catpizo ACKNOWLEDGMENT A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracv, or validity of that document. STATE OF CALIFORNIA COUNTY OF 2ille(, S'jJ-jo On j r�j r? a I before m , L„ M , j_jAz A Notary Public personally appeared R a t e.l a-o A nd R OCA 0 U e.l as 0- 0 who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s)W-are subscribed to the within instrument and acknowledged to me that 1p6loe/they executed the same in Yslprltheir authorized capacity(ies), and that by Mstyerltheir signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, ex cuted the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. Signature L. M. DE LA LUZ Commission # 2059240 ,s Notary Public - California z z "'F Riverside County n (Seal) MY Comm. Expires Feb 27, 20ta Order No. 210-1809207-10 Exhibit "A" Lot 17 in Block 112 of Santa Carmelita at Vale La Quinta, Unit 12, in the City of La Quinta, County of Riverside, State of California, as per Map recorded in Book 18, Pages 79-80 of Maps, in the office of the County Recorder of said County. BOE-502-A (P1) REV. 12 (05-13) PRELIMINARY CHANGE OF OWNERSHIP REPORT To be completed by the transferee (buyer) prior to a transfer of subject property, in accordance with section 480.3 of the Revenue and Taxation Code. A Preliminary Change of Ownership Report must be filed with each conveyance in the County Recorder's office for the county where the property is located. /e 49 57— > NAME AND MAILING ADDRESS OF BUYER/TRANSFEREE (Make necessary corrections to the printed name and mailing address) Southern International Company, Inc Attn: Andrew Castro 41490 Sparkey Way Bermuda Dunes CA 92203 773-143-008-9 ASSESSOR'S PARCEL NUMBER Raul Velasco and Rocio Velasco SELLER/TRANS EROR (760)272-0412 BUYER'S DAYTIME TELEPHONE NUMBER AndrewJCastro@earthlink.net BUYER'S EMAIL ADDRESS STREET ADDRESS OR PHYSICAL LOCATION OF REAL PROPERTY Avenida Mendoza - APN# 773-143-008-9, La Quinta, CA 92253 MAIL PROPERTY TAX INFORMATION TO (NAME) Southern International Company, Inc - Attn: Andrew Castro ADDRESS CITY STATE ZIP CODE 41490 Sparkey Way Bermuda Dunes CA 92203 ( ) YES K ) NO This property is intended as my principal residence. If YES, please indicate the date of occupancy MO I DAY YEAR or intended occupancy. PART 1. TRANSFER INFORMATION Please complete all statements. YES N ( ) A. This transfer is solely between spouses (addition or removal of a spouse, death of spouse, divorce settlement, etc.). B. This transfer is solely between domestic partners currently registered with the California Secretary of State (addition or removal of a partner, death of a partner, termination settlement, etc.). C. This is a transfer: ( ) between parent(s) and child(ren) ( ) from grandparent(s) and grandchild(ren). ( ) D. This transfer is the result of a cotenant's death. Date of death ( ) E. This transaction is to replace a principal residence by a person 55 years of age or older. Within the same county? ( ) YES ( ) NO ,�%+ ( ) F. This transaction is to replace a principal residence by a person who is severely disabled as defined by Revenue and Taxation Code section 69.5. Within the same county? ( ) YES ( ) NO ( j G. This transaction is only a correction of the name(s) of the person(s) holding title to the property (e.g., a name change upon marriage). H. If YES, please explain: The recorded document creates, terminates, or reconveys a lender's interest in the property. I. This transaction is recorded only as a requirement for financing purposes or to create, terminate, or reconvey a security interest (e.g., cosigner). If YES, please explain: ( y ( ) J. The recorded document substitutes a trustee of a trust, mortgage, or other similar document. K. This is a transfer of property: ( )) 1. to/from a revocable trust that may be revoked by the transferor and is for the benefit of [ ] the transferor, and/or [ ] the transferor's spouse [ ] registered domestic partner. ( ) 2. to/from a trust that may be revoked by the creator/grantor/trustor who is also a joint tenant, and which names the other joint tenant(s) as beneficiaries when the creator/grantor/trustor dies. )) 3. to/from an irrevocable trust for the benefit of the [ ] creator/grantor/trustor and/or [ ] grantor's/trustor's spouse [ ] grantor's/trustor's registered domestic partner. ( ) 4. to/from an irrevocable trust from which the property reverts to the creator/grantor/trustor within 12 years. L. This property is subject to a lease with a remaining lease term of 35 years or more including written options. ( } M. This is a transfer between parties in which proportional interests of the transferor(s) and transferee(s) in each and every parcel being transferred remain exactly the same after the transfer. ( )) N. This is a transfer subject to subsidized low-income housing requirements with governmentally imposed ( ) ( -0. restrictions. This transfer is to the first purchaser of a new building containing an active solar energy system. *Please refer to the instructions for Part 1 Please provide any other information that will help the Assessor understand the nature of the transfer. THIS DOCUMENT IS NOT SUBJECT TO PUBLIC INSPECTION r SOE-502-A (P1) REV. 12 (05-13) Ai 773-143-008-9 PART 2. OTHER TRANSFER INFORMATION A. Date of transfer, if other than recording date: B. Ty a of transfer { Purchase ( ) Foreclosure ( ) Gift ( ) Trade or Exchange ( ) Merger, stock or partnership acquisition (Form BOE-100-B) [ ) Contract of sale. Date of contract ( ) Inheritance. Date of death: { } Sale/leaseback ( ) Creation of a lease ( ) Assignment of a lease [ ) Termination of a lease. Date lease began: Original term in years (including written options): Remaining term in years (including written options). - Other: Please explain: Check and complete as applicable. C. Only a partial interest in the property was transferred? ( ) YES 4NO If YES, indicate the percentage transferred % PART 3. PURCHASE PRICE AND TERMS OF SALE Check and complete as applicable. A. Total purchase price $ �] � L B. Cash down payment or value of trade or exchange excluding closing costs Amount ° :C. First deed of trust @ % Interest rate for years. Monthly Payment $ Amount $ =� — ( ) FHA (_ Discount Points) ( ) Cal -Vet ( ) VA (_Discount Points) ( ) Fixed Rate ( ) Variable Rate ( ) Bank/Savings & Loan/Credit Union ( ) Loan Carried by seller ( ) Balloon Payment $ Due Date: D. Second Deed of Trust @ % interest for years. Monthly Payment $ Amount $ T ( ) Fixed Rate ( ) Variable Rate ( ) Bank/Savings & Loan/Credit Union ( ) Loan carried by seller ( ) Balloon Payment $ Due Date: $ E. Was an Improvement Bond or other public financing assumed by the buyer? ( ) YES ("-AO Outstanding balance $ - �) F. Amount, if any, of real estate commission fees paid by the buyer which are not included in the utcha @ price i_n,_�,tt er �7� I t 421-S ��� G. The property was purchased: (Through real estate broker. Broker name: i T 12--W f7 R�tJ� Phone Number{7 b D)a)_S' ( ) Direct from seller ( ) From a family member -Relationship ( ) Other: Please explain: H. Please explain any special terms, seller concessions, broker/agent fees waived, financing, and any other information (e.g. buyer assumed the existing loan balance) that would assist the Assessor in the valuation of your property: k) PART 4. PROPERTY INFORMATION Check and complete as applicable. A. Type of property transferred ( ) Single-family residence ( ) Multiple -family residence. Number of units: ( ) Co-op/Own-your-own ( ) Manufactured home ( ) Other. Description: (i.e., timber, mineral, water rights, etc.) ( ) Condominium (� Unimproved lot ( ) Timeshare ( ) Commercial/Industrial B. ( ) YES ((j NO Personal/business property, or incentives, are included in the purchase price. Examples are furniture, farm equipment, machinery, club 1) memberships, etc. Attach list if available. If YES, enter the value of the persanalrbusiness property: $ C. ( ) YES (}[.) NO A manufactured home is included In the purchase price. If YES, enter the value attributed to the manufactured home: $ ( ) YES ( ) NO The manufactured home is subject to local property tax. If NO, enter decal number: D. ( ) YES ( NO The property produces rental or other income. If YES, the income is from: ( ) Lease/rent ( ) Contract ( ) Mineral rights ( ) Other: E. The condition of the property at the time of sale was: ( ) Good ( ) Average (' Fair ( ) Poor CERTIFICATION I certify (or declare) under penalty of perjury under the laws of the State of Calitomia that the foregoing and all information hereon, including any accompanying ctatamanhz nrrrnrrrmanlc i.c trim anri r.mmrrt in tha ha.cf of my hnnurlarina and hollaf Thic darlarafinn is hinrfrnrr nn aarh and AVOn1 hrruarllrancfiorAA SIG NA RE OF BUYER/TRANSFEREE ZORRPORATE OFFICER DATE NAME OF BUYS (TRANSFEREE/LE AESENTATIVEICORPTE OFFICER (PLEASE PRINT) TITLE E-MAIL ADDRESS i ne Assessor s oTrrce may contact you ror aaartionai inrormation regaramg finis transaction. PETER ALDANA Recorder P. O. Box 751 COUNTY OF RIVERSIDE Riverside, CA 92502-0751 ASSESSOR -COUNTY CLERK -RECORDER (951) 486-7000 Website: www.riversideacr.com DOCUMENTARY TRANSFER TAX AFFIDAVIT WARNING ANY PERSON WHO MAKES ANY MATERIAL MISREPRESENTATION OF FACT FOR THE PURPOSE OF AVOIDING ALL OR ANY PART OF THE DOCUMENTARY TRANSFER TAX IS GUILTY OF A MISDEMEANOR UNDER SECTION 5 OF ORDINANCE 516 OF THE COUNTY OF RIVERSIDE AND IS SUBJECT TO PROSECUTION FOR SUCH OFFENSE. ASSESSOR'S PARCEL NO. 7737-143-008-9 1 declare that the documentary transfer tax for this Property Address: APN# 773-143-008-9, La Quinta, transaction is: CA 92253 If this transaction is exempt from Documentary Transfer Tax, the reason must be identified below. I CLAIM THAT THIS TRANSACTIONIS EXEMPT FROM DOCUMENTARY TRANSFER TAX BECAUSE. (The Sections listed below are taken from the Revenue and Taxation Code with the exception of items 9 and 10 which are taken from Riverside County Ordinance 516). Please check one or explain in "Other".) i . Section 11911. The consideration or value of the property, exclusive of any liens and encumbrances is $100.00 or less and there is no additional consideration received by the grantor. 2. Section 11911. The conveyance transfers to a revocable living trust by the grantor or from a revocable living trust to a beneficiary. 3. Section 11921. The conveyance was given to secure a debt. 4. Section 11922. The conveyance is to a governmental entity or political subdivision 5. Section 11925. The transfer is between individuals and a legal entity or partnership, or between legal entities, and does not change the proportional interests held. 6. Section 11926. The conveyance is to a grantee who is the foreclosing beneficiary and the consideration paid by the foreclosing beneficiary does not exceed the unpaid debt. 7. Section 11927. The conveyance relates to a dissolution of marriage or legal separation. (A spouse must sign a written recital in order to claim this exemption. This form may be used for that purpose). 8. Section 11930. The conveyance is an inter vivos gift* or a transfer by death. * Please be aware that information stated on this document may be given to and used by governmental agencies, including the Internal Revenue Service. Also, certain gifts in excess of the annual Federal gift tax exemption may trigger a Federal Gift Tax. In such cases, the Transferor (donor/grantor) may be required to file Form 709 (Federal Gift Tax Return) with the Internal Revenue Service. 9. Section 8. The easement is not perpetual, permanent, or for life. 10. Section 9. The document is a lease for a term of less than (35) years (including written options). 11. Other (Include explanation and authority) I DECLARE UNDER PENALTY OF PERJURY THAT THE FOREGOING IS TRUE AND CORRECT. Executed is day of Oc. obev_ 901(vat L-a- u 'a+z , Cify state Signature of Affiant Printed Name o Affiant Solaris Escrow, Inc. 78-100 Main Street, Suite 204, La Quinta, CA 92253 Name of Firm (if applicable) Address of Affiant (including City, State, and 2;r Code) (760)501-0466 Telephone Number ofAfifiant (including area code) This form is subject to the California Public Records Act (Government Code 6250 et. seq.) For Recorder's Use: -- Affix PCOR Label Here ACR 521 (Rev. 11/2014) Building Permit Number: Project Description: I SFR Exempt: El (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Plan Submittal Job Site Owner's Name Number, Street, or PO City, State, Postal ( Owner's Phone Nur Owner's E-Mail Add 1 /23/2018 51680 Avd. Mendoza Southern International Co -Inc. 41490 Sparkey Way Bermuda Dunes, CA 92203 Ff1 fteEL L o_)( L_sC iS EnS1 Si (:.co rri Project Manager's Name I Andrew Project Manager's Phone Number 760-272-0579 Project Manager's E-mail Address Af1Ei[L'YY_@7 dL _S E;m Ies]Ei l_c t)rn Builder/ Contractorl Desert Isles, Inc. Number, Street or PO Boxi 41490 Sparkey Way City, State, Postal Code I Bermuda Dunes, CA 92203 Project Square City Approval By 1,702 Date of City Approval fi / Z �f%j Materials To Be Discarded: Product Tons Trash 3.23 Not recyclable Asphalt 0.00 Recyclable Brick/Block 0.00 Recyclable Cardboard 0.56 Recyclable Commingled 0.00 Recyclable Concrete 0. 141 Recyclable Drywall 0.10 Recyclable Donated / Reuse* 0.00 Recyclable Product Tons Masonry (broken) 0.00 Plaster 0.34 Scrap Metal 0.00 Tile (floor) 0.29 Tile (roof? 0.00 Wood 4.26 Landscape Debris 0.00 `Describe Items 71 'Totals: Recycle Trash Projected Diversion: 5.7 1 3.2 63.7% I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobslte waste is diverted from landfllling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bi-month) reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer Owner /��/f' / Developer I P ect Man ger I Superintendent mate Design Concepts Drafting t De5ign Service Phone (760)365-8742 57445 29 Palm5 Hwy., Suite 304 Fax (760)365-8743 Yucca Valley, CA 92284 E-Mail: de5ign.onhne@verizon.net Title 24 Energy Compliance Documentation Castro Project Ave Mendoza La Quinta, CA 92253 Climate Zone 15 8-31-17 Method of compliance: Performance Method using CBECC-RES 2016. This project is in compliance with the 2016 Edition of the California Residential Energy Efficiency Standards when built as documented in this submittal. Space Heating: Afue of 82 Air Conditioning: 16 seer Water Heater: 50 gallon with .7 EF and 50,000 btu Glazing: Type Ufactor SHGC Front door .31 .28 Fixed .42 .38 Slider .60 .31 XO .54 .36 Wall Insulation: R-21 Ceiling Insulation: R-38 Roof Deck Insulation: R-11 Quality Insulation Inspection required ?65Z017- 008� TY OF LA QUINTA BUILDING DIVISION REVIEWED FOR ODE COMPUANCE OATS If OF-riCF, RECEIVED MAY 16 2018 CITY OF LA QUINTA COMMUNITY DEVELOPMENT CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Castro Calculation Date/Time: 15:09, Thu, Aug 31, 2017 Calculation Description: Input File Name: Castro-CORRECTION.ribd16 CF1 R-PRF-01 Page 1 of 9 GENERAL INFORMATION 01 Project Name Castro 02 Calculation Description 03 Project Location Ave. Mendoza 04 City La Quinta, CA 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.2.1 (695) 08 Climate Zone CZ15 09 Software Version CBECC-Res 2016.2.1 (868) 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 1702 15 Number of Zones 1 16 Slab Area (ft2) 1702 17 Number of Stories 1 18 Addition Cond. Floor Area n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) n/a 21 Glazing Percentage (%) 17.3% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below This compliance analysis is valid only for permit applications through October 24, 2017 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 0.94 1.94 -1.00 -106.4% Space Cooling 96.06 90.60 5.46 5.7% IAQ Ventilation 1.27 1.27 0.00 0.0% Water Heating 7.45 10.24 -2.79 -37.4% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 105.72 104.05 1.67 1.6% Registration Number: 217-P0100804618-000-000-0000000-0000 Registration Date/Time: 2017-08-31 15:16:20 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-31 15:10:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Castro Calculation Date/Time: 15:09, Thu, Aug 31, 2017 Calculation Description: Input File Name: Castro-CORRECTION.ribdl6 CF1 R-PRF-01 Page 2 of 9 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Raised heel truss • Insulation below roof deck • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: -- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Castro 1702 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 1 Conditioned HVAC System 1 1702 9.5 DHW System 1 Registration Number: 217-P01008046113-000-000-0000000-0000 Registration Date/Time: 2017-08-31 15:16:20 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-31 15:10:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Castro Calculation Date/Time: 15:09, Thu, Aug 31, 2017 Calculation Description: Input File Name: Castro-CORRECTION.ribd16 CFI R-PRF-01 Page 3 of 9 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) front wall Zone 1 exterior walls 270 Front 180.5 54 90 back wall Zone 1 exterior walls 90 Back 380 97 90 left wall Zone 1 exterior walls 0 Left 665 93 90 right wall Zone 1 exterior walls 180 Right 430 50 90 garage back Zone 1»Garage interior walls 199.5 0 garage left Zone 1 —Garage interior walls 142.5 0 Ceiling (below attic) living Zone 1 ceiling 1702 garage front wall Garage exterior walls 270 Front 199.5 112 90 garage left wall Garage exterior walls 0 Left 71.25 0 90 garage right wall Garage exterior walls 180 Right 216 0 90 Ceiling (below attic) garage Garage ceiling 478 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic 1 Asphalt Shingle Roof Ventilated 5 0.1 0.85 No No Registration Number: 217-PQ100804618-000-000-0000000-0000 Registration Date/Time: 2017-08-31 15:16:20 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-31 15:10:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Castro Calculation Date/Time: 15:09, Thu, Aug 31, 2017 Calculation Description: Input File Name: Castro-CORRECTION.ribd16 CF1 R-PRF-0" Page 4 of 9 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading front door Window front wall (Front-270) 3.0 8.0 1 1 24.0 0.31 0.28 Insect Screen (default) Living front Window front wall (Front-270) 6.0 5.0 1 30.0 0.54 0.36 Insect Screen (default) kitchen sink Window back wall (Back-90) 5.0 5.0 1 25.0 0.54 0.36 Insect Screen (default) kitchen slider Window back wall (Back-90) 8.0 8.0 1 64.0 0.60 0.31 Insect Screen (default) master shower Window back wall (Back-90) 4.0 2.0 1 8.0 0.54 0.36 Insect Screen (default) living left Window left wall (Left-0) 2.0 5.0 2 20.0 0.42 0.38 None dining Window left wall (Left-0) 5.0 5.0 1 25.0 0.54 0.36 Insect Screen (default) master slider Window left wall (Left-0) 6.0 8.0 1 48.0 0.60 0.31 Insect Screen (default) middle bedroom Window right wall (Right-180) 5.0 5.0 1 25.0 0.54 0.36 Insect Screen (default) front bedroom Window right wall (Right-180) 5.0 5.0 1 25.0 0.54 0.36 Insect Screen (default) OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor garage door garage front wall 112.0 1.00 Registration Number: 217-P01008046113-000-000-0000000-0000 Registration Date/Time: 2017-08-31 15:16:20 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-31 15:10:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Castro Calculation Date/Time: 15:09, Thu, Aug 31, 2017 Calculation Description: Input File Name: Castro-CORRECTION.ribdl6 CF1 R-PRF-01 Page 5 of 9 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up front door 7.5 1 1 1 0 9.5 1 1 0 7.5 1 1 0 Living front 0 0 0 0 0 0 0 0 0 0 0 0 0 kitchen sink 2 1 10.5 3 0 28 1 10.5 0 0 0 0 0 kitchen slider master shower 2 0 1 0 0.5 0 10.5 0 0 0 28 0 1 0 0.5 0 0 0 0 0 0 0 0 0 0 0 living left 0 0 0 0 0 0 0 0 0 0 0 0 0 dining 0 0 0 0 0 0 0 0 0 0 0 0 0 master slider middle bedroom 2 0 1 0 4.5 0 17.5 0 0 0 0 0 0 0 0 0 0 0 19 0 1 0 17.5 0 0 0 front bedroom 0 0 0 0 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-value Assembly Layers • Cavity/Frame: R-11 /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Asphalt Shingle Roof Attic Roofs Wood Framed Ceiling in. O.C. R 11 0.088 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9 1 /2x4 ceiling attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 • Sheathing/Insulation: Wood Siding/sheathing/decking exterior walls Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.065 Exterior Finish: 3 Coat Stucco Inside Finish: Gypsum Board interior walls Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.064 Cavity/Frame: R-21 /2x6 Other Side Finish: Gypsum Board Registration Number: 217-p010080461B-000-000-0000000-0000 Registration Date/Time: 2017-08-31 15:16:20 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-31 15:10:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R-PRF-0 i Project Name: Castro Calculation Date/Time: 15:09, Thu, Aug 31, 2017 Page 6 of 9 Calculation Description: Input File Name: Castro-CORRECTION.ribd16 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab On Grade living Zone 1 1702 220 None 0.8 No Slab On Grade garage Garage 478 87.5 None 0 No WATER HEATERS 01 02 03 04 1 05 06 07 08 09 10 11 Tank Energy Tank Insulation Tank Location or Heater Number Volume Factor or Input R-value Standby Loss / Ambient Name Element Type Tank Type of Units (gal) Efficiency Rating/Pilot (Int/Ext) Recovery Eff NEEA Heat Pump Type Condition Water Heater 1 Gas Small Storage 1 50 0.7 EF 50,000 Btu/hr R-0 n/a 0 n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC System 1 y Other Heating and Cooling System Heating System 1 Cooling System 1 HVAC Fan System 1 Distribution System 1 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating System 1 CntrlFurnace 1 82 AFUE Registration Number: 217-Po10060461B-000-000-0000000-0000 Registration Date/Time: 2017-08-31 15:16:20 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-31 15:10:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Castro Calculation Date/Time: 15:09, Thu, Aug 31, 2017 Page 7 of 9 Calculation Description: Input File Name: Castro-CORRECTION.ribd16 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Efficiency Name System Type Number of Units EER SEER Zonally Controlled Compressor Type HERS Verification Cooling System 1 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling System 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling System 1-hers-cool Required 350 Not Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Deeply Buried Low -leakage Name Verification Target (%) Location Design Ducts Ducts Air Handler Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan System 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan System 1-hers-fan Required 0.58 Registration Number: 217-P010080461B-000-000-0000000-0000 Registration Date/Time: 2017-08-31 15:16:20 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-31 15:10:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Castro Calculation Date/Time: 15:09, Thu, Aug 31, 2017 Calculation Description: Input File Name: Castro-CORRECTION.ribd16 CF1 R-PRF-04 Page 8 of 9 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 47 0.25 Default 0 Required Registration Number: 217-Po100804618-000-000-0000000-0000 Registration Date/Time: 2017-08-31 15:16:20 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2017-08-31 15:10:19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Castro Calculation Date/Time: 15:09, Thu, Aug 31, 2017 Page 9 of 9 Calculation Description: Input File Name: Castro-CORRECTION.ribd16 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature Brian Diebolt %Ova Company: Signature Date: Design Concepts 2017-08-31 15:16:20 Address: CEA/HERS Certification Identification (If applicable): 57445 29 Palms Hwy, Ste 304 City/State/Zip: Phone: Yucca Valley, CA 92284 760-365-8742 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California. i . I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations. plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Brian Diebolt 0Z4*WV&k Company: Date Signed: Design Concepts 2017-08-31 15:16:20 Address: License: 57445 29 Palms Hwy, Ste 304 000 City/State/Zip: Phone: Yucca Valley, CA 92284 760-365-8742 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 217-P010060461B-000-000-0000000-0000 Registration Date/Time: 2017-06-31 15:16:20 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Easy to Verify at CaICERTS-com HERS Provider: CaICERTS inc- Report Generated at: 2017-08-31 15:10:19 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply. r{eVJSe0 U4%N111 Building Envelope Measures: § 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft' or less when tested per NFRC-400 orASTM E283 orAAMAIWDMAICSA 101/I.S.2/A440-2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b) Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES " 110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed. § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 114.8(g): Insulation Requirements for Heated Slab Floors. Healed slab floors must be insulated per the requirements of § 110.8(g). Roofing Products Solar Reflectance and Thermal Emittance. The thermal amiltance and aged solar reflectance values of the roofing material must meet therequirements of § 110,8 i when the installation of a cool roof Is s pecified on the CFIR. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.* § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U- § 150.0(c): factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly." § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor." § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 11 0.8. § 150.0(g)1. Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class 11 vapor retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d). § 150.0(g}2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class 11 vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air - permeable insulation. § 150 0(q); Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U factor of 0.58; or the we' hied ave 29e U-factor of all fenestration must not exceed 0.58 ' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)lA: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)l C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission." § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K." Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for su2plementary heating.* § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat." Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 110 3(c)7: Isolation Valves. instantaneous water heaters with an input racing greater than 6.8 kBTUlhr (2 kW) must have isolation valves with hose bibbs or other fittin s on bath cold water and hot water lines of water heali ng systems to allow for water tank fl us h ing when the valves are closed. § 110 5: Pilot Lights. Continuously buming pilot lights are prohibited for natural gas: fan -type central fumace% household Booking appliances (appli- ances without an electrical sLipply voltage connection with pilot lights that consume less than 150 Btulhr are exempt); and pool ands a heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; orACCA Manual J using design conditions specified in § 150.0(h)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insufaflon R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.` § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve." § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution piping for steam and f1 dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class I I vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1 120V electrical receptacle within 3 feel of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water healer, and allows natural draining without pump assistance; and a Qas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a listing en that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must cer& to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ''/<inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tam unless such tape is used In combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually aerated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier, Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)l 1: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m 11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, _pressure drop, and labeling requirements of § 150.0(m)12. y 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy15 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of rovi ing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing. in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.* § 110.4(b)1- Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves." Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9." § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1 C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k)." Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 ; and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 f ; and all other requirements in § 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0 k 2. #Wwk 2016 Low -Rise Residential Mandator Measures Summary _ § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in haltw § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residenlial buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 1,50.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150 0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0 kc 3A or with the applicable r uirements in §§ 110.9, 130.0. 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B or§ 150,0(k)30 must comply with theapplicable requirements in §§ 110.9, 130.0, 130.2, 130.4,140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles pef site must comply with the applicable meguirements in §§ 110.9, 130.0, 1302, 130.4,140.7, and 141.0. § 150,0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of ower as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the a licable r uirements for nanresideniial ar es in 110.9, 130.0, 130.1, 130,4, 140.6, and 141.0. Interior Common Areas of Low•rise Multi -Family Residential Buildings. In aloes -rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that buildi must be hi h efficac luminaires and controlled h an occu ant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In aloes -rise rnrrltifamdy residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and li. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 Eercent. The occupant sensors must be capable of turning the light ful!y on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences leas been deemed complete by the enforcement agency must comply with the requirements of § 110.10 b through § 110.10 e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 30 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted a ui ment.' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical ane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be dearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service ape!); and a pathway for routing of plumbing from the solar zone to the water-heatings tem. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110A 0(b) through 110.10 c must be provided to the occu nt. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit - § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit lWalion, and permanently marked as "For Future Solar Electric".