BRES2018-012178-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type/Subtype:
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
Applicant:
CHRISTOPHER GRIFFITH
`ter 4 4Qu&M
DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED
BRES2018-0121
53125 AVENIDA RAMIREZ
774051016
MARCUS / 1,854SF DWELLING/VB/RES-3/CLASS A-FR/13D
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Owner:
ADRIANA MARQUEZ
53145 AVENIDA RAMIREZ
LA QUINTA, CA 92253
Date: 10/30/2018
$119,246.00
nContractor:
V DD STATEWIDE SERVICES INC DBA STATEWIDE CON
OCT 3 0 2018 73-700 DINAH SHORE DR #405
PALM DESERT, CA 92211
CITY OF LA QUINTA (760)673-8980
DESIGN & DEVELOPMENT DEPARTMENT Llc. No.: 951607
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 70001 of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: 5 License No.: 95160
Conti`BY+tbr:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
() I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
() I am exempt under Sec. . B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Na
Lender's
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of ri w rk for which this permit is issued.
ave and will maintain workers' compensation insurance, as required by
Sects❑ 3 00 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: BENCHMARK INSURANCEGOMPANY Policy Number: CST5012063
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with hose pro[vWons.
pte: i"5 A"Ot:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST. AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above -{mentioned property for inspection pur ases.
f Y e (Applicant or Agent)
Date: 10/30/2018
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
Applicant:
CHRISTOPHER GRIFFITH
BRES2018-0121
53125 AVENIDA RAM IREZ
774051016
MARCUS / 1,854SF DWELLING/VB/RES-3/CLASS A-FR/13D
$119, 246.00
Owner:
ADRIANA MARQUEZ
53145 AVENIDA RAMIREZ
LA QUINTA, CA 92253
Contractor:
STATEWIDE SERVICES INC DBA STATEWIDE CON
73-700 DINAH SHORE DR #405
PALM DESERT, CA 92211
(760)673-8980
:Llc. No.: 951607
Detail: 1,854SF DWELLING - [VB/RES-3/CLASS A-FR/13D] THIS•PERMIT DOES NOT INCLUDE POOL, SPA,,BLOCK WALLS OR DRIVEWAY APPROACH. A FINISH
FLOOR ELEVATION CERTIFICATION BY A LICENSED SURVEYOR OR ENGINEER IS REQUIRED PRIOR TO FOUNDATION INSPECTION. 2016 CALIFORNIA BUILDING
CODES.
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT CITY AMOUNT
BSAS SB1473 FEE
101-0000-20306 0 $5.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $5.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - CIVIC CENTER
252-0000-43200
0
$942.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - COMMUNITY CENTERS
254-0000-43200
0
$129.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - FIRE PROTECTION
257-0000-43200
0
$433.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF- LIBRARIES
253-0000-43200
0
$344.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - PARK MAINTENANCE
256-0000-43200
0
$40.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - PARKS/REC
251-0000-43200
0
$2,048.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - STREET MAINTENANCE
255-0000-43200
0
$116.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF-TRANSPORTATION
250-0000-43200
0
$2,842.00
Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TEMP POWER SERVICE
101-0000-42403
0
$26.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TEMP POWER SERVICE PC
101-0000-42600
0
$18.20
Total Paid for ELECTRICAL: $44.21
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF
101-0000-42403
0
$26.52
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF, PC
101-0000-42600
0
$10.92
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$156.04
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$51.49
Total Paid for ELECTRICAL- NEW CONSTRUCTION: $244.97
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF
101-0000-42408
0
$39.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF PC
101-0000-42600
0
$39.01
Total Paid for GRADING: $78.02
DESCRIPTION
ACCOUNT
I CITY AMOUNT
CONDENSER/COMPRESSOR
DESCRIPTION
CONDENSER/COMPRESSOR PC
DESCRIPTION
EXHAUST HOOD
DESCRIPTION
EXHAUST HOOD PC
DESCRIPTION
FURNACE
DESCRIPTION
FURNACEPC
DESCRIPTION
VENT FAN
DESCRIPTION
VENT FAN PC
DESCRIPTION
MULTI -SPECIES RESIDENTIAL 8.1-14 UNITS - 2018 UPDATE
DESCRIPTION
NEW CONSTRUCTION PERMIT
DESCRIPTION
NEW CONSTRUCTION PLAN CHECK
DESCRIPTION
PLAN CHECK DEPOSIT - RESIDENTIAL
DESCRIPTION
BACKFLOW DEVICE
DESCRIPTION
BACKFLOW DEVICE PC
DESCRIPTION
BUILDING SEWER
DESCRIPTION
BUILDING SEWER PC
DESCRIPTION
-------------
FIXTURE/TRAP
DESCRIPTION
FIXTURE/TRAP PC
DESCRIPTION
GAS SYSTEM, 5+ OUTLETS
101-0000-42402 p
1
$39.01
ACCOUNT CITY
AMOUNT
101-0000-42600 p
$26.01
ACCOUNT CITY
AMOUNT
101-0000-42402 p
$13.00
ACCOUNT CITY
AMOUNT
101-0000-42600 p
$5.20
ACCOUNT CITY
AMOUNT
101-0000-42402 p
$39.01
ACCOUNT CITY
AMOUNT
101-0000-42600 p
$26.01
ACCOUNT CITY
AMOUNT
101-0000-42402 p
$52.00
ACCOUNT CITY
AMOUNT
101-0000-42600 p
$20.80
l Paid for MECHANICAL:
$221.04
EEAEMIES
ULTI-SPECIES RESIDENTIAL:
.
1722za5ES
Total Paid for NEW CONSTRUCTION PERMIT:
.
ACCOUNT CITY
AMOUNT
101-0000-42600 p
$1,094.72
Total Paid for NEW CONSTRUCTION PLAN CHECK:
$1,094.72
ACCOUNT QTY
AMOUNT
101-0000-42600 1
$750.00
Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL:
750.00
ACCOUNT CITY
AMOUNT
101-0000-42401 p
$13.00
ACCOUNT CITY
AMOUNT
101-0000-42600 p
$5.20
ACCOUNT CITY
AMOUNT
101-0000-42401 p
$26.01
ACCOUNT QTY
AMOUNT
101-0000-42600 p
$18.20
ACCOUNT CITY
AMOUNT
101-0000-42401 p
$143.00
ACCOUNT QTY
AMOUNT
101-0000-42600 p
$143.00
ACCOUNT CITY
AMOUNT
101-0000-42401 p
$39.01
DESCRIPTION
ACCOUNT CITY
AMOUNT
GAS SYSTEM, 5+ OUTLETS PC
101-0000-42600 0
$26.01
DESCRIPTION
ACCOUNT CITY
AMOUNT
ROOF DRAIN
101-0000-42401 0
$52.00
DESCRIPTION
ACCOUNT CITY
AMOUNT
ROOF DRAIN PC
101-0000-42600 0
$52.00
DESCRIPTION
ACCOUNT CITY
AMOUNT
WATER HEATER/VENT
101-0000-42401 0
$13.00
DESCRIPTION
ACCOUNT CITY
AMOUNT
WATER HEATER/VENT PC
101-0000-42600 0
$7.80
Total Paid for PLUMBING FEES:
$538.23
DESCRIPTION
ACCOUNT CITY
AMOUNT
RECORDS MANAGEMENT FEE - MAJOR
101-0000-42416 0
$20.00
Total Paid for RECORDS MANAGEMENT FEE - MAJOR:
$20.00
DESCRIPTION
ACCOUNT CITY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308 0
$15.50
Total Paid for STRONG MOTION INSTRUMENTATION SMI:
$15.50
DESCRIPTION
ACCOUNT CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611 0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE:
$5.00
DESCRIPTION
ACCOUNT CITY
AMOUNT
101-0000-42600
($750.00)
DESCRIPTION
ACCOUNT CITY
AMOUNT
SINGLE FAMILY DETACHED
224-0000-20320 0
$1,087.44
DESCRIPTION
ACCOUNT CITY
AMOUNT
SINGLE FAMILY DETACHED
224-0000-20320 0
$750.00
Total Paid for TUMF - RESIDENTIAL:
$1,087.44
a�raPERMIT#GEM,fr/xESE1rr 1-!
taQ
A01<
PLAN LOCATION:
Project Address: 53-125 Avenida Ramirez
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #: 774-051-016
New single family residence
Applicant Name: Adriana Marcus
Address: 53-125 Avenida Ramirez
City, ST, Zip: La Quinta, CA 92253
Telephone: Contact: Christopher (760) 673-0989
Email: chris.griffith@dcmgmt.biz
Valuation of Project $ $180,000.00
Contractor Name:
New SFD Construction:
Address:
Conditioned Space
1,854 SF
City, St, Zip
Garage
461 SF
Telephone:
Patio/Porch
17 SF
Email:
Fire Sprinklers
2,332 SF
State Lic: City Bus Lic:
Arch/Eng Name: Gabriel Rios
Construction Type: VB Occupancy: R-3
Address: 49-901 Cinnabar Lane
Grading: No
City, St, Zip Coachella, CA 92236
Telephone: 760-485-7431
Bedrooms: 3
Stories: 1
# Units: N/A
Email: riosdesigns@yahoo.com
State Lic: N/A City Bus Lic:
Property Owner's Name: Adriana Marcus
New Commercial / Tenant Improvements:
Address:
Total Building SF
City, ST, Zip
Construction Type: Occupancy:
Telephone:
Email:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
Date: 10/30/2018
No.: 18-01154-1
Owner: Adriana Marcus
Address: 78120 Calle Estado #203
City: La Quinta
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
479SO Dune Palms Road
La Quinta, CA 922S3
(760)771-8S1S
Type: Single Family Residential
Lot # Street No. Street Name
53-145
53-125
Comments:
Avenida Ramirez
Avenida Ramirez
Email:
Jurisdiction: La Quinta
Tract #:
Sq. Feet APN
1854 774-051-017
1854 774-051-016
0
MKI T'uOA o uNEs
+^ ROitiortn p[wEELL?E y
,�piLL1RMAC 19TA
Permit No.
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for ilving, sleeping, cooking eating, or sanitation) or replacement
mobile homes. It has been determined that the above -named owner is exempt From paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility Tess imposed pursuant to
Education Code Section 17620 and Government Code 6599S Et Seq.
in the amount of $3.79 X 3708 S.F. or $24,053.32 have been paid for the property listed above and that building
permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Fees Paid By: C Check No.: 1589608440
Bank Name/Recipient of Certificate Telephone: 760-673-9089
By Scott L. Bailey Funding: Residential
Superintendent
Fee Collected/ Exempted by: Arianne Catano
Certificate Fees Due: $14,053.32
Original PaymeOtts) Rec'd: $0.00
New Payment Rec'd: $14,053.32
Over/ $0.00
NOTICE; Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may Protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another publ#c entity authorized to collect them an the District('s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
RECORDING REQUESTED BY:
WESTERN RESOURCES TITLE COMPANY
RECORDINGtEQU£STED BY:
ProNet farm ,Inc., DBA Sun Gold
Escro
Order No. 'S r `l Escrow No. 10869-CC
Parcel No. 774-051-016-9, 774-051-017-0
AND WREN RECORDED MAIL TO:
ADRIANA MARQUEZ
5zOi?5 Aocne,L-, Lhtle,d
LaC�nfeL O. 5 y q;-3
DOC # 2017-0286099
07/13/2017 02:27 PM Fees: $24.00
Page 1 of 4
Recorded in Official Records
County of Riverside
Peter Aldana
Assessor -County Clerk -Recorder
"This document was electronically submitted
to the County of Riverside for recording"
Receipted by: SOPHIA #466
SPACE ABOV81'AES LENS li°OR RECORDMS USE
02D45 INTERSPOUSAL TRANSFER GRANT DEED
(Excluded from reappraisal under California Constitution Act 13 A Let.seq.)
'DOCUMENTARY TRANSFER TAX $too
f
This is an InterspouseL Transfer and not a change in a ership under §63 of the Revenue and Taxation Code and Grantor(s)
has (have) checked the applicable exclusion from reappraisal:
❑ From Joint Teoancy to Community Properly
❑ From 1�ne Spouse to Both spouses This conveyance establishes
® From One Spouse to the Other Spouse sole and separate property of a
❑ From Both Spouses to the Other Spouse Cl Other, spouse, R & T 11911
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, GRANTOR
Corrado Marquez, spouse of grantee
hereby GRANTS to Adriana Marquez, a married woman as her sole and separate property
the real property in the City of La Qulnta County of RI)erside, State of California:
SEE EXHIBIT "A' ATTACHED HERETO AND MADh A PART HEREOF
More commoli ly known as: Vancaut Land Avenida Rajnirez, 774-051-016-9 And 774-051-017-0, La Qulnta, CA 92253
Wyk Dated 2017
A notary public or other officer completing this
to which this certificate is_attached, and not the I
verifies only the Identity of the individual w signed the
accuracy or validity of ih.t Anr„m * i
STATE OF CALIFQRNIA
COUNTY OF V A } 5.5.
On —� t LAi l t" ZD L le before me, �• CLi L-.. - i'U' 1 LLB, Q N KA PY P 11 &Ut,
personally appeared
who proved to me on the basis of satisfactory evidence to be the person(s) whose narric(s) is/are bscxibed to the within
instrument aid acknnowledged to me that he/she/they executed the same in his/her/their authorized caPaoity(
instrnmenL ies), and that by
hustler/their siguature(s) on the instrument the person(&), or the entity upon bahalf of which the per& n(s) acted, executed the
I certify under PENALTY OF PERJURY under the Ia of the Sr/0
hie true and
correct' CHERI L. MILLER It—p
Tl� my d ofi'i &cal , Commission # 206t1939
QM�Comm.Explre
Notary Public - California' Rlverslde CountSignature (Sea])s Jun.12, 2018
Mail Tax Statements to: S'IAME AS ABOVF or Address Noted Below
DOC #2017-0286099 Page 2 of 4
CERTIFICATION
Under the provision of Government Code 27361.7, I certify
under the penalty that the following is a true copy of illegible
wording found in the attached document.
(Print or Type the page— n m rks) and Wordingbelow);
"See Attached Document for Clarity"
DATE: Co - a -a - n
SIGNATURE: G6—
Christina Gaytan, DPS Employee
RECORDING REQUESTED BY:
ProNet Partners, Inc., DBA Sun Gold
Escrow
Order No. 138478
Escrow No. 10868-CC
Parcel No. 774-051-016-9, 774-051-017-0
AND WHEN RECORDED MAM TO:
ADRLANA MARQUEZ
FOR
DOC #2017-0286099 Page 3 of 4
INTERSPOUSAL TRANSFER GRANT DEED
(Excluded from reappraisal under California Constitution Act 13 A Let.seq.)
DOCUMENTARY TRANSFER TAX SQ.QO
This is an Interspousal Transfer and not a change in ownership under §63 of the Revenue and Taxation Code and Grantor(s)
has (have) checked the applicable exclusion from reappraisal. -
El From Joint Tenancy to Community Property
❑ From One Spouse to Both Spouses
® From One Spouse to the Other Spouse
❑ From Both Spouses to the Other Spouse
❑ Other:
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, GRANTOR
Conrado Marquez, spouse of grantee
hereby GRANTS to Adriana Marquez, a married woman as her sole and separate property
the real property in the City of La Quinta County of Riverside, State of California:
SEE EXRMIT "A" ATTACHED HERETO AND MADE A PART R=OF
More commonly known as: Vancant Land Avenida Ramirez, 774-051-016-9 And 774-051-017-0, La Quinta, CA 92253
Dated June 22, 2017
A notary public or other officer
to which this certificate is attach
STATE OF CALIFORNIA
COUNTY OF
Con
ttng this certificate verifies only the identity of the individual who signed the document
not the truthfubiess, accuraa, or validity ofthat document.
} S.S.
before me,
personally appeared '
who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within
instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by
his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the
instrument.
I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and
correct.
WITNESS my hand and official seal.
Signature
(Seal)
Mail Tax Statements to: SAME AS ABOVE or Address Noted Below
DOC #2017-0286099 Page 4 of'4
EXHIBIT "A►,
LEGAL DESCRIPTION
Real property In the.City of La Quinta, County of Riverside, State of California, described as follows:
LOTS 5 AND 6 IN BLOCK 220, OF SANTA CARMELITA UNIT NO.21, AS PER MAP RECORDED
IN BOOK 20, PAGE 22 OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID
COUNTY.
APN: 774-051-016 774-051-017
Western Resources Title Company
Building Permit Number:
Project Description: SFR - -- -
Exempt: ❑ --~
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
Plan Submittal
Job Site
Owners
Number, Street, or PO
City, State, Postal C
Owner's Phone Nun
Owners E-Mail Adds
Project Manager's Name
Project Manager's Phone Number
Project Manager's E-mail Address
Builder I
Number, Street or PO Box
City, State, Postal Code
10/29/2018
53125 & 53145 Avenida Ramirez
Adriana Marcus
53154 Avenida Ramirez
La Quinta, CA. 92253
c/o 760-673-8980
Santiago Porales
c/o 760-673-8980
chri - riff] h cm mi.b'x
Statewide Services Inc
78120 Calle Estado #203
La Quinta, CA. 92253
Project Square Footage) Approx. 3,708 sq ft(2-homes @1,854 sq ft each)
OCT 310 2018
CIT3l OF UA 01,?NTA
City Approval By
Renado GouldlocklDEC-aurrtec Waste C.
Date of City Approval
101 Z � i 0,
Materials To Be Discarded:
Product
Tons
Trash
16.50 Nol recyclable
Product
Tons
Asphalt
0,00 Recyclable
Masonry (broken) i
0.00 Recyclable
Brick/Block
0.00 Recyclable
Plaster
4.60 Recyclable
Cardboard
Commingled
0.00 Recyclable
0.00 Recyclable
Scrap Metal
0.00 Recyclable
Concrete
18.00 Recyclable
Tile (floor)
Tile (roof)
0,40 Recyclable
0.50 Recyclable
Drywall
Donated /Reuse"
1.90 Recyclable
0.00 Recyclable
Wood
Landscape Debris
6.50 recyclable
0.00 Recyclable
"Describe Items
Totals: iiec cte Trash
Projected Diversion:
31.9
16.5
135.9196
I understand it Is the properly owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is
diverted from landfiiling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or
demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still
Issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the
DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through
bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer
Owner I Developer / Project Manager I Superintendant g31
J
EsGil
A SAFEUuilt Company
DATE: 6/6/2018 ❑ APPLICANT
L�'JURIS.
JURISDICTION: LA QUINTA
PLAN CHECK #.: BRES2018-0121 SET: II
PROJECT ADDRESS: 53-125 AVENIDA RAMIREZ
PROJECT NAME: SFD FOR MARCUS (STRUCTURAL ONLY)
® The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
❑ The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
❑ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
❑ The applicant's copy of the check list has been sent to:
® EsGil staff did not advise the applicant that the plan check has been completed.
❑ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (b ) Email:
Mail Telephone Fax 11nerson
❑ REMARKS:
By: Bert Domingo Enclosures:
EsGil
5/30/2018
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Marcus Residence
53-125 Avenida Ramirez
La Quinta, CA 92253
Project Designer:
Rios Designs
49-901 Cinnabar Lane
Coachella, Ca 92236
760-485-7431
Report Prepared by:
Joan Hacker
Insu-form, Inc.
43585 Monterey Avenue, Suite 7
_ 6TrF i c' Palm Desert, Ca 92260
CITY OF LA Q I NTA 760-345-1352
BUILDING & SAFE-FY DEPT.
APPROVED
FOR MNSTRUCTION
DA1 1 7 BY �
'a-01Z\ Job Number: RECEIVED
MAY 2 5 2018
Date: CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
5/18/2018
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft com.
I TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF-1 R-PRF-01-E Certificate of Compliance 3
Form RMS-1 Residential Measures Summary 11
Form MF-1 R Mandatory Measures Summary 12
HVAC System Heating and Cooling Loads Summary 16
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 12:53, Fri, May 18, 2018
Calculation Description: Title 24 Analysis
Input File Name: Marcus Residence 53-125 Avenida Ramirez.ribd16x
CF1 R-PRF-01
Page 1 of 8
GENERAL INFORMATION
01
Project Name
Single Family Residence
02
Calculation Description
Title 24 Analysis
03
Project Location
53-125 Avenida Ramirez
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.0 (934 SP1)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.2
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
90
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ftZ)
1854
15
Number of Zones
1
16
Slab Area (ftZ)
1854
17
Number of Stories
1
18
Addition Cond. Floor Area(ftZ)
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ftZ)
n/a
21
1 Glazing Percentage (%)
12.8%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDVe yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating "-
2.16
4.31
-2.15
-99.5%
Space Cooling
94.27
91.05
3.22
3.4%
IAQ Ventilation
, 1.20
1.20
0.00
0.0%
Water Heating
7.83
-1.00
-14.6%
Photovoltaic Offset
—
0.00
0.00
—
Compliance Energy Total
104.46
104.39
0.07
0.1%
Registration Number: 418-P010034051A-000-000-0000000-0000 Registration Date/Time: 05/23/2018 12:38 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2018-05-18 12:53:51
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:53, Fri, May 18, 2018
Input File Name: Marcus Residence 53-125 Avenida Ramirez.ribd16x
CF1 R-PRF-01
Page 2 of 8
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency
EDR of Proposed Efficiency
EDR Value of Proposed PV + Battery
Final Proposed EDR
55.6
55.5
0.0
55.5
❑
Design meets Tier 1 requirement of 15°k or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified.
Notes:
• Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering NEM rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cool roof
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
-y`
• Verified EER
n •� '� —
• Verified SEER
• Verified Refrigerant ChargeL-
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
• — None —
— ys• ,
J ■ sr
Registration Number: 418-P010034051A-000-000-0000000-0000 Registration Date/Time: 05/23/2018 12:38 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2018-05-18 12:53:51
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: Single Family Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:53, Fri, May 18, 2018 Page 3 of 8
Input File Name: Marcus Residence 53-125 Avenida Ramirez.ribd16x
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Single Family Residence
1854
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Whole House
Conditioned
Whole House1
1854
10
DHW Sys 1
n/a
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
Front Wall
Whole House
R-21 Wall
90
Front
600
66.4
90
Left Wall
Whole House
R-21 Wall
180
Left
500
62
90
Rear Wall
Whole House
R-21 Wall
270
Back
600
52
90
Right Wall
Whole House
R-21 Wall
0
Right
500
56
90
Roof
Whole House
R-08 Roof Attic
n/a
n/a
1854
n/a
n/a
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Whole House
Attic RoofWhole House
VentilatoA
0
0.5 J
0.75
Yes
Yes
Registration Number: 418-P010034051A-000-000-0000000-0000 Registration Dateffime: 05/23/2018 12:38 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2018-05-18 12:53:51
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 12:53, Fri, May 18, 2018
Calculation Description: Title 24 Analysis
Input File Name: Marcus Residence 53-125 Avenida Ramirez.ribd16x
CF1 R-PRF-01
Page 4 of 8
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
Window
Window
Front Wall (Front-90)
-
-
1
7.5
0.40
0.26
Insect Screen (default)
Window
Window
Front Wall (Front-90)
-
-
1
3.0
0.40
0.26
Insect Screen (default)
Window 3
Window
Front Wall (Front-90)
-
-
1
33.4
0.40
0.26
Insect Screen (default)
Window 4
Window
Front Wall (Front-90)
-
-
1
7.5
0.40
0.26
Insect Screen (default)
Window 5
Window
Front Wall (Front-90)
-
-
1
3.0
0.40
0.26
Insect Screen (default)
Window 6
Window
Front Wall (Front-90)
-
-
1
12.0
0.40
0.26
Insect Screen (default)
Window 7
Window
Left Wall (Left-180)
-
-
1
25.0
0.40
0.26
Insect Screen (default)
Window 8
Window
Left Wall (Left-180)
-
-
1
25.0
0.40
0.26
Insect Screen (default)
Window 9
Window
Left Wall (Left-180)
-
-
1
4.0
0.40
0.26
Insect Screen (default)
Window 10
Window
Left Wall (Left-180)
-
-
1
4.0
0.40
0.26
Insect Screen (default)
Window 11
Window
Left Wall (Left-180)
-
-
1
4.0
0.40
0.26
Insect Screen (default)
Window 12
Window
Rear Wall (Back-270)
-
-
1
40.0
0.40
0.26
Insect Screen (default)
Window 13
Window
Rear Wall (Back-270)
--
-
1
12.0
0.40
0.26
Insect Screen (default)
Window 14
Window
Right Wall (Right-0)
-
-
1
8.0
0.40
0.26
Insect Screen (default)
Window 15
Window
Right Wall_.(.Fight-0)
-
-
1
16.0
0.40
0.26
Insect Screen (default)
Window 16
Window
Right.WaIVI- fight-0)
-
-
1
8.0
0.40
0.26
Insect Screen (default)
Window 17
Window
Right 1i�[all.{Right-0)
-
-
1
16.0
0.40
0.26
Insect Screen (default)
Window 18
Window
Right Wail4Right-0)
-
-
1
8.0
1 0.40
0.26
1 Insect Screen (default)
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
• Cavity/Frame: no insul /2x4 Top Chrd
-
Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofWhole House
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing. Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity/Frame: R-21/2x6
R-21 Wall
Exterior Walls
Wood Framed -Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
Registration Number: 418-P010034051A-000-000-0000000-0000 Registration Date/Time: 05/23/2018 12:38 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2018-05-18 12:53:51
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 12:53, Fri, May 18, 2018
Calculation Description: Title 24 Analysis
Input File Name: Marcus Residence 53-125 Avenida Ramirez.ribdl6x
CF1 R-PRF-01
Page 5 of 8
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area W2)
Perimeter (ft)
Edge Insul. R-value S Depth
Carpeted Fraction
Heated
Slab -on -Grade
Whole House
1854
585
None
1
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1 (1)
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Input Rating!
Tank
Standby
Heater
Tank
Uniform Energy
Pilot/
Insulation
Loss /
First Hour
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
NEEA Heat Pump
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Brand I Model
Condition
DHW Heater 1
Gas
Small Storage
1
1 50
1 0.8 EF
1 46,000 Btu/hr
0
n/a
n/a
In/a
In/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
Whole House1
Whole
Other Heating and Cooling
system
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFurnace
1
80 AFUE
Registration Number: 418-P010034051A-000-000-0000000-0000 Registration Date/Time: 05/23/2018 12:38 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2018-05-18 12:53:51
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 12:53, Fri, May 18, 2018
Calculation Description: Title 24 Analysis
Input File Name: Marcus Residence 53-125 Avenida Ramirez.ribdl6x
CF1 R-PRF-01
Page 6 of 8
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Name
System Type
Number of Units
Efficiency
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low4eakage
Air Handler
Air Distribution System 1-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed -PSG ce Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
- `' 02
03
Name
' ;Verified Fan Waft Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
Registration Number: 418-P010034051A-000-ODO-0000000-0000 Registration Date/Time: 05/23/2018 12:38 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2018-05-18 12:53:51
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:53, Fri, May 18, 2018
Input File Name: Marcus Residence 53-125 Avenida Ramirez.ribdl6x
CF1 R-PRF-01
Page 7 of 8
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
49
0.25
Default
0
Required
QUINTA
�_L DEPT
rtjCTICN
Registration Number: 418-P010034051A-000-000-0000000-0000 Registration Date/Time: 05/23/2018 12:38 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2018-05-18 12:53:51
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 12:53, Fri, May 18, 2018
Calculation Description: Title 24 Analysis
Input File Name: Marcus Residence 53-125 Avenida Ramirez.ribdl6x
CF1 R-PRF-01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Joan Hacker
J6anNac*er
Company:
Signature Date:
Joan Hacker
05/22/2018
Address:
CEA/HERS Certification Identification (if applicable):
72875 Fred Waring Drive
City/State/Zip:
Phone:
Palm Desert, CA 92260
760-345-1352
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Gabriel Rios
GabrCaF-'aa
Company:
Date Signed:
Rios Designs
05/23/2018
Address:
License:
49-901 Cinnabar Lane
City/State/Zip:
Phone:
Coachella, CA 92236 - --
760-485-7431
UINTA
V`D
Y
Digitally signed by CHEERSTM. This digital signature is provided in order to secure the content of this registered
document and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 418-P010034051A-000-000-0000000-0000 Registration Date/Time: 05/23/2018 12:38 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2018-05-18 12:53:51
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Marcus Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
511812018
Project Address
53-125 Avenida Ramirez La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
1,854
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity ft) Special Features
Status
Wall Wood Framed R 21 1,964
Slab Unheated Slab -on -Grade - no insulation 1,854 Perim = 585'
New
New
Roof Wood Framed Attic R 38 1.854 Cool Roof
New
FENESTRATION I Total Area: 236 Glazirkg Percentage: 12.6% New/Altered Ave a U-Factor:
Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades
0.40
Status
Front (E) 66.4 0.400
0.26 none none Bug Screen
New
Left (S) 62.0 0.400
0.26 none none Bug Screen
New
Rear (M 520 0.400
0.26 none none Bug Screen
New
Right (N) 56.0 0.400
0.26 none none Bug Screen
New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat
Status
1 Central Furnace 80•/6 AFUE
Split Air Conditioner 16 0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value
Status
Whole House Ducted
Ducted Attic 8.0
New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution
Status
1 Small Storage Gas 50
0.60 Standard
New
Ener_qyPro 72bVEnergySoft User Number: 2655
ID:
Pa a 11 of 16
e x1�
"s -- t 2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. 'Exceptions may apply.
{ ilno nal 08/2016)
Building Envelope Measures:
§ 110.6(a)1:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft' or less when tested per
NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 10l/I.S.2/A440-2011.'
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.'
§ 110 7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 110.8 i when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceiling.*
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or
§ 150.0(c):
less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a
wood framed assembly!
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.`
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.31/o; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 11 0.8p .
§ 150.0(g)1
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d).
§ 150.0(g)2:
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58: or the weighted average U-factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e) lA:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1 B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)1C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control!
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the buildin , are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b)
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.'
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.`
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ I i0.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)5.
§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
_
§ 110.5:
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt): and pool ands a heaters
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)1:
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; orACCA
Manual J using design conditions specified in § 150.0 h 2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the cullel of any
dryer vent.
§ 150.0(h)3B:
_
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.0011:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.'
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casinn or sleeve!
§ 150.00)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.'
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.0013A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause de radation of the material.
§ 150.0013B:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)1.
12OV electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation SRCC or by a listing a enc that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CIVIC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1:
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than A inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such toe is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field4abricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers, _
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air o enin s and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0 m 11and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labelin requirements of § 150.0(m)12. _
O*Z��_WJIT 2016 Low -Rise Residential Mandato Measures Summary
V
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow ? 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced air systems!
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o).
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
§ 150.0(o)1A:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference ResidentialAppendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating!
§ 110.4(b)1:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
§ 150.0(p)
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, pi in , filters, and valves'
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of § 110.9 -
§ 110.9(e):
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)1 D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors.
§ 150.0(k)1F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the apgicable r uirements of § 150.0 k ,'
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1G:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8'
§ 150.0(k)1 H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturers instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5(f); and meets all other requirements in § 150.0(k)2.
_
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5 : and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used tocomply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.*
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS.
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either § 150.0 k 3A or with the applicable requirements in q 110.9, 130.0. 130.2. 130.4. 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0 k 3B or § 150.0 k 3D must com& with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must comply with the applicable requirements in $110.9. 130.0. 130.2. 130.4. 140.7, and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0(c).
§ 150.0(k)5:
_
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in §§ 110.9, 130.0,130.1. 130.4. 140.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the III: fullx on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.1 0b through § 110.10 e .
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.*
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical lane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water-heatin s stem.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
1 10.10c must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Marcus Residence
Date
5/18/2018
System Name
Whole House
Floor Area
1,854
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 830
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
i 86,000
19,846
1,832
956
34,820
Total Output (Btuh)
86,000
0
Output Btuh/s ft
46.4
1,146
1,711
Cooling S tem
0
0
Output per system
58,000
0
0
0
0
Total Output Btuh
58,000
0
1,146
1 22,137 1,832
0
Total Output Tons
4-8
1,711
Total Output (Btuh/s ft)
31.3
Total Output s ftrron
383.6
38,242
Air S tem
CFM per System
2,055
HVAC EQUIPMENT SELECTION
Airflow cfm
2,055
York GCGD 60S 415 3A
43,997
5,684
86,000
Airflow cfm/s t
1.11
Airflow cfm/Ton
425.2
Outside Air %
0.0/0
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
43,997 5,684
Aug 3 PM
86,000
Jan 1 AM
Outside Air cfm/s ft
0.00
Note: values above given at ARI conditions I
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 69 OF
Outside Air AV-
0 cfm Supply Fan
2,055 cfm
69 OF
69 °F 105 OF rn,
1
Heating Coil
�I I 1 I H 4
i
104 OF
ROOM
70 IF
.1
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112178 OF 79 ! 63 OF 79 ! 63 °F 55 / 54 °F
Outside Air
0 cfm Supply Fan Cooling Coil
2,055 cfm
79/63°F ]
56154 OF
�----
421% ROOM
78/63°F
EnergyPro 7.2 by EnergySoft User Number: 2655