Loading...
BRES2018-012178-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: CHRISTOPHER GRIFFITH `ter 4 4Qu&M DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED BRES2018-0121 53125 AVENIDA RAMIREZ 774051016 MARCUS / 1,854SF DWELLING/VB/RES-3/CLASS A-FR/13D VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: ADRIANA MARQUEZ 53145 AVENIDA RAMIREZ LA QUINTA, CA 92253 Date: 10/30/2018 $119,246.00 nContractor: V DD STATEWIDE SERVICES INC DBA STATEWIDE CON OCT 3 0 2018 73-700 DINAH SHORE DR #405 PALM DESERT, CA 92211 CITY OF LA QUINTA (760)673-8980 DESIGN & DEVELOPMENT DEPARTMENT Llc. No.: 951607 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: 5 License No.: 95160 Conti`BY+tbr: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: () I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). () I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of ri w rk for which this permit is issued. ave and will maintain workers' compensation insurance, as required by Sects❑ 3 00 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: BENCHMARK INSURANCEGOMPANY Policy Number: CST5012063 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with hose pro[vWons. pte: i"5 A"Ot: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST. AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -{mentioned property for inspection pur ases. f Y e (Applicant or Agent) Date: 10/30/2018 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: CHRISTOPHER GRIFFITH BRES2018-0121 53125 AVENIDA RAM IREZ 774051016 MARCUS / 1,854SF DWELLING/VB/RES-3/CLASS A-FR/13D $119, 246.00 Owner: ADRIANA MARQUEZ 53145 AVENIDA RAMIREZ LA QUINTA, CA 92253 Contractor: STATEWIDE SERVICES INC DBA STATEWIDE CON 73-700 DINAH SHORE DR #405 PALM DESERT, CA 92211 (760)673-8980 :Llc. No.: 951607 Detail: 1,854SF DWELLING - [VB/RES-3/CLASS A-FR/13D] THIS•PERMIT DOES NOT INCLUDE POOL, SPA,,BLOCK WALLS OR DRIVEWAY APPROACH. A FINISH FLOOR ELEVATION CERTIFICATION BY A LICENSED SURVEYOR OR ENGINEER IS REQUIRED PRIOR TO FOUNDATION INSPECTION. 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $5.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $5.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF- LIBRARIES 253-0000-43200 0 $344.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARKS/REC 251-0000-43200 0 $2,048.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF-TRANSPORTATION 250-0000-43200 0 $2,842.00 Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 DESCRIPTION ACCOUNT CITY AMOUNT TEMP POWER SERVICE 101-0000-42403 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT TEMP POWER SERVICE PC 101-0000-42600 0 $18.20 Total Paid for ELECTRICAL: $44.21 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $26.52 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $10.92 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $156.04 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $51.49 Total Paid for ELECTRICAL- NEW CONSTRUCTION: $244.97 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF 101-0000-42408 0 $39.01 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF PC 101-0000-42600 0 $39.01 Total Paid for GRADING: $78.02 DESCRIPTION ACCOUNT I CITY AMOUNT CONDENSER/COMPRESSOR DESCRIPTION CONDENSER/COMPRESSOR PC DESCRIPTION EXHAUST HOOD DESCRIPTION EXHAUST HOOD PC DESCRIPTION FURNACE DESCRIPTION FURNACEPC DESCRIPTION VENT FAN DESCRIPTION VENT FAN PC DESCRIPTION MULTI -SPECIES RESIDENTIAL 8.1-14 UNITS - 2018 UPDATE DESCRIPTION NEW CONSTRUCTION PERMIT DESCRIPTION NEW CONSTRUCTION PLAN CHECK DESCRIPTION PLAN CHECK DEPOSIT - RESIDENTIAL DESCRIPTION BACKFLOW DEVICE DESCRIPTION BACKFLOW DEVICE PC DESCRIPTION BUILDING SEWER DESCRIPTION BUILDING SEWER PC DESCRIPTION ------------- FIXTURE/TRAP DESCRIPTION FIXTURE/TRAP PC DESCRIPTION GAS SYSTEM, 5+ OUTLETS 101-0000-42402 p 1 $39.01 ACCOUNT CITY AMOUNT 101-0000-42600 p $26.01 ACCOUNT CITY AMOUNT 101-0000-42402 p $13.00 ACCOUNT CITY AMOUNT 101-0000-42600 p $5.20 ACCOUNT CITY AMOUNT 101-0000-42402 p $39.01 ACCOUNT CITY AMOUNT 101-0000-42600 p $26.01 ACCOUNT CITY AMOUNT 101-0000-42402 p $52.00 ACCOUNT CITY AMOUNT 101-0000-42600 p $20.80 l Paid for MECHANICAL: $221.04 EEAEMIES ULTI-SPECIES RESIDENTIAL: . 1722za5ES Total Paid for NEW CONSTRUCTION PERMIT: . ACCOUNT CITY AMOUNT 101-0000-42600 p $1,094.72 Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,094.72 ACCOUNT QTY AMOUNT 101-0000-42600 1 $750.00 Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: 750.00 ACCOUNT CITY AMOUNT 101-0000-42401 p $13.00 ACCOUNT CITY AMOUNT 101-0000-42600 p $5.20 ACCOUNT CITY AMOUNT 101-0000-42401 p $26.01 ACCOUNT QTY AMOUNT 101-0000-42600 p $18.20 ACCOUNT CITY AMOUNT 101-0000-42401 p $143.00 ACCOUNT QTY AMOUNT 101-0000-42600 p $143.00 ACCOUNT CITY AMOUNT 101-0000-42401 p $39.01 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT ROOF DRAIN 101-0000-42401 0 $52.00 DESCRIPTION ACCOUNT CITY AMOUNT ROOF DRAIN PC 101-0000-42600 0 $52.00 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $13.00 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $7.80 Total Paid for PLUMBING FEES: $538.23 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $20.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $20.00 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $15.50 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $15.50 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($750.00) DESCRIPTION ACCOUNT CITY AMOUNT SINGLE FAMILY DETACHED 224-0000-20320 0 $1,087.44 DESCRIPTION ACCOUNT CITY AMOUNT SINGLE FAMILY DETACHED 224-0000-20320 0 $750.00 Total Paid for TUMF - RESIDENTIAL: $1,087.44 a�raPERMIT#GEM,fr/xESE1rr 1-! taQ A01< PLAN LOCATION: Project Address: 53-125 Avenida Ramirez Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: 774-051-016 New single family residence Applicant Name: Adriana Marcus Address: 53-125 Avenida Ramirez City, ST, Zip: La Quinta, CA 92253 Telephone: Contact: Christopher (760) 673-0989 Email: chris.griffith@dcmgmt.biz Valuation of Project $ $180,000.00 Contractor Name: New SFD Construction: Address: Conditioned Space 1,854 SF City, St, Zip Garage 461 SF Telephone: Patio/Porch 17 SF Email: Fire Sprinklers 2,332 SF State Lic: City Bus Lic: Arch/Eng Name: Gabriel Rios Construction Type: VB Occupancy: R-3 Address: 49-901 Cinnabar Lane Grading: No City, St, Zip Coachella, CA 92236 Telephone: 760-485-7431 Bedrooms: 3 Stories: 1 # Units: N/A Email: riosdesigns@yahoo.com State Lic: N/A City Bus Lic: Property Owner's Name: Adriana Marcus New Commercial / Tenant Improvements: Address: Total Building SF City, ST, Zip Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 Date: 10/30/2018 No.: 18-01154-1 Owner: Adriana Marcus Address: 78120 Calle Estado #203 City: La Quinta CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 479SO Dune Palms Road La Quinta, CA 922S3 (760)771-8S1S Type: Single Family Residential Lot # Street No. Street Name 53-145 53-125 Comments: Avenida Ramirez Avenida Ramirez Email: Jurisdiction: La Quinta Tract #: Sq. Feet APN 1854 774-051-017 1854 774-051-016 0 MKI T'uOA o uNEs +^ ROitiortn p[wEELL?E y ,�piLL1RMAC 19TA Permit No. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for ilving, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above -named owner is exempt From paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility Tess imposed pursuant to Education Code Section 17620 and Government Code 6599S Et Seq. in the amount of $3.79 X 3708 S.F. or $24,053.32 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: C Check No.: 1589608440 Bank Name/Recipient of Certificate Telephone: 760-673-9089 By Scott L. Bailey Funding: Residential Superintendent Fee Collected/ Exempted by: Arianne Catano Certificate Fees Due: $14,053.32 Original PaymeOtts) Rec'd: $0.00 New Payment Rec'd: $14,053.32 Over/ $0.00 NOTICE; Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may Protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another publ#c entity authorized to collect them an the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. RECORDING REQUESTED BY: WESTERN RESOURCES TITLE COMPANY RECORDINGtEQU£STED BY: ProNet farm ,Inc., DBA Sun Gold Escro Order No. 'S r `l Escrow No. 10869-CC Parcel No. 774-051-016-9, 774-051-017-0 AND WREN RECORDED MAIL TO: ADRIANA MARQUEZ 5zOi?5 Aocne,L-, Lhtle,d LaC�nfeL O. 5 y q;-3 DOC # 2017-0286099 07/13/2017 02:27 PM Fees: $24.00 Page 1 of 4 Recorded in Official Records County of Riverside Peter Aldana Assessor -County Clerk -Recorder "This document was electronically submitted to the County of Riverside for recording" Receipted by: SOPHIA #466 SPACE ABOV81'AES LENS li°OR RECORDMS USE 02D45 INTERSPOUSAL TRANSFER GRANT DEED (Excluded from reappraisal under California Constitution Act 13 A Let.seq.) 'DOCUMENTARY TRANSFER TAX $too f This is an InterspouseL Transfer and not a change in a ership under §63 of the Revenue and Taxation Code and Grantor(s) has (have) checked the applicable exclusion from reappraisal: ❑ From Joint Teoancy to Community Properly ❑ From 1�ne Spouse to Both spouses This conveyance establishes ® From One Spouse to the Other Spouse sole and separate property of a ❑ From Both Spouses to the Other Spouse Cl Other, spouse, R & T 11911 FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, GRANTOR Corrado Marquez, spouse of grantee hereby GRANTS to Adriana Marquez, a married woman as her sole and separate property the real property in the City of La Qulnta County of RI)erside, State of California: SEE EXHIBIT "A' ATTACHED HERETO AND MADh A PART HEREOF More commoli ly known as: Vancaut Land Avenida Rajnirez, 774-051-016-9 And 774-051-017-0, La Qulnta, CA 92253 Wyk Dated 2017 A notary public or other officer completing this to which this certificate is_attached, and not the I verifies only the Identity of the individual w signed the accuracy or validity of ih.t Anr„m * i STATE OF CALIFQRNIA COUNTY OF V A } 5.5. On —� t LAi l t" ZD L le before me, �• CLi L-.. - i'U' 1 LLB, Q N KA PY P 11 &Ut, personally appeared who proved to me on the basis of satisfactory evidence to be the person(s) whose narric(s) is/are bscxibed to the within instrument aid acknnowledged to me that he/she/they executed the same in his/her/their authorized caPaoity( instrnmenL ies), and that by hustler/their siguature(s) on the instrument the person(&), or the entity upon bahalf of which the per& n(s) acted, executed the I certify under PENALTY OF PERJURY under the Ia of the Sr/0 hie true and correct' CHERI L. MILLER It—p Tl� my d ofi'i &cal , Commission # 206t1939 QM�Comm.Explre Notary Public - California' Rlverslde CountSignature (Sea])s Jun.12, 2018 Mail Tax Statements to: S'IAME AS ABOVF or Address Noted Below DOC #2017-0286099 Page 2 of 4 CERTIFICATION Under the provision of Government Code 27361.7, I certify under the penalty that the following is a true copy of illegible wording found in the attached document. (Print or Type the page— n m rks) and Wordingbelow); "See Attached Document for Clarity" DATE: Co - a -a - n SIGNATURE: G6— Christina Gaytan, DPS Employee RECORDING REQUESTED BY: ProNet Partners, Inc., DBA Sun Gold Escrow Order No. 138478 Escrow No. 10868-CC Parcel No. 774-051-016-9, 774-051-017-0 AND WHEN RECORDED MAM TO: ADRLANA MARQUEZ FOR DOC #2017-0286099 Page 3 of 4 INTERSPOUSAL TRANSFER GRANT DEED (Excluded from reappraisal under California Constitution Act 13 A Let.seq.) DOCUMENTARY TRANSFER TAX SQ.QO This is an Interspousal Transfer and not a change in ownership under §63 of the Revenue and Taxation Code and Grantor(s) has (have) checked the applicable exclusion from reappraisal. - El From Joint Tenancy to Community Property ❑ From One Spouse to Both Spouses ® From One Spouse to the Other Spouse ❑ From Both Spouses to the Other Spouse ❑ Other: FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, GRANTOR Conrado Marquez, spouse of grantee hereby GRANTS to Adriana Marquez, a married woman as her sole and separate property the real property in the City of La Quinta County of Riverside, State of California: SEE EXRMIT "A" ATTACHED HERETO AND MADE A PART R=OF More commonly known as: Vancant Land Avenida Ramirez, 774-051-016-9 And 774-051-017-0, La Quinta, CA 92253 Dated June 22, 2017 A notary public or other officer to which this certificate is attach STATE OF CALIFORNIA COUNTY OF Con ttng this certificate verifies only the identity of the individual who signed the document not the truthfubiess, accuraa, or validity ofthat document. } S.S. before me, personally appeared ' who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. Signature (Seal) Mail Tax Statements to: SAME AS ABOVE or Address Noted Below DOC #2017-0286099 Page 4 of'4 EXHIBIT "A►, LEGAL DESCRIPTION Real property In the.City of La Quinta, County of Riverside, State of California, described as follows: LOTS 5 AND 6 IN BLOCK 220, OF SANTA CARMELITA UNIT NO.21, AS PER MAP RECORDED IN BOOK 20, PAGE 22 OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. APN: 774-051-016 774-051-017 Western Resources Title Company Building Permit Number: Project Description: SFR - -- - Exempt: ❑ --~ (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Plan Submittal Job Site Owners Number, Street, or PO City, State, Postal C Owner's Phone Nun Owners E-Mail Adds Project Manager's Name Project Manager's Phone Number Project Manager's E-mail Address Builder I Number, Street or PO Box City, State, Postal Code 10/29/2018 53125 & 53145 Avenida Ramirez Adriana Marcus 53154 Avenida Ramirez La Quinta, CA. 92253 c/o 760-673-8980 Santiago Porales c/o 760-673-8980 chri - riff] h cm mi.b'x Statewide Services Inc 78120 Calle Estado #203 La Quinta, CA. 92253 Project Square Footage) Approx. 3,708 sq ft(2-homes @1,854 sq ft each) OCT 310 2018 CIT3l OF UA 01,?NTA City Approval By Renado GouldlocklDEC-aurrtec Waste C. Date of City Approval 101 Z � i 0, Materials To Be Discarded: Product Tons Trash 16.50 Nol recyclable Product Tons Asphalt 0,00 Recyclable Masonry (broken) i 0.00 Recyclable Brick/Block 0.00 Recyclable Plaster 4.60 Recyclable Cardboard Commingled 0.00 Recyclable 0.00 Recyclable Scrap Metal 0.00 Recyclable Concrete 18.00 Recyclable Tile (floor) Tile (roof) 0,40 Recyclable 0.50 Recyclable Drywall Donated /Reuse" 1.90 Recyclable 0.00 Recyclable Wood Landscape Debris 6.50 recyclable 0.00 Recyclable "Describe Items Totals: iiec cte Trash Projected Diversion: 31.9 16.5 135.9196 I understand it Is the properly owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is diverted from landfiiling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still Issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer Owner I Developer / Project Manager I Superintendant g31 J EsGil A SAFEUuilt Company DATE: 6/6/2018 ❑ APPLICANT L�'JURIS. JURISDICTION: LA QUINTA PLAN CHECK #.: BRES2018-0121 SET: II PROJECT ADDRESS: 53-125 AVENIDA RAMIREZ PROJECT NAME: SFD FOR MARCUS (STRUCTURAL ONLY) ® The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ❑ The applicant's copy of the check list has been sent to: ® EsGil staff did not advise the applicant that the plan check has been completed. ❑ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (b ) Email: Mail Telephone Fax 11nerson ❑ REMARKS: By: Bert Domingo Enclosures: EsGil 5/30/2018 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 BUILDING ENERGY ANALYSIS REPORT PROJECT: Marcus Residence 53-125 Avenida Ramirez La Quinta, CA 92253 Project Designer: Rios Designs 49-901 Cinnabar Lane Coachella, Ca 92236 760-485-7431 Report Prepared by: Joan Hacker Insu-form, Inc. 43585 Monterey Avenue, Suite 7 _ 6TrF i c' Palm Desert, Ca 92260 CITY OF LA Q I NTA 760-345-1352 BUILDING & SAFE-FY DEPT. APPROVED FOR MNSTRUCTION DA1 1 7 BY � 'a-01Z\ Job Number: RECEIVED MAY 2 5 2018 Date: CITY OF LA QUINTA COMMUNITY DEVELOPMENT 5/18/2018 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft com. I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01-E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 11 Form MF-1 R Mandatory Measures Summary 12 HVAC System Heating and Cooling Loads Summary 16 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 12:53, Fri, May 18, 2018 Calculation Description: Title 24 Analysis Input File Name: Marcus Residence 53-125 Avenida Ramirez.ribd16x CF1 R-PRF-01 Page 1 of 8 GENERAL INFORMATION 01 Project Name Single Family Residence 02 Calculation Description Title 24 Analysis 03 Project Location 53-125 Avenida Ramirez 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.0 (934 SP1) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ftZ) 1854 15 Number of Zones 1 16 Slab Area (ftZ) 1854 17 Number of Stories 1 18 Addition Cond. Floor Area(ftZ) n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ftZ) n/a 21 1 Glazing Percentage (%) 12.8% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDVe yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating "- 2.16 4.31 -2.15 -99.5% Space Cooling 94.27 91.05 3.22 3.4% IAQ Ventilation , 1.20 1.20 0.00 0.0% Water Heating 7.83 -1.00 -14.6% Photovoltaic Offset — 0.00 0.00 — Compliance Energy Total 104.46 104.39 0.07 0.1% Registration Number: 418-P010034051A-000-000-0000000-0000 Registration Date/Time: 05/23/2018 12:38 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2018-05-18 12:53:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 12:53, Fri, May 18, 2018 Input File Name: Marcus Residence 53-125 Avenida Ramirez.ribd16x CF1 R-PRF-01 Page 2 of 8 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 55.6 55.5 0.0 55.5 ❑ Design meets Tier 1 requirement of 15°k or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering NEM rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow -y` • Verified EER n •� '� — • Verified SEER • Verified Refrigerant ChargeL- • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • — None — — ys• , J ■ sr Registration Number: 418-P010034051A-000-000-0000000-0000 Registration Date/Time: 05/23/2018 12:38 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2018-05-18 12:53:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 12:53, Fri, May 18, 2018 Page 3 of 8 Input File Name: Marcus Residence 53-125 Avenida Ramirez.ribd16x BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Single Family Residence 1854 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Whole House Conditioned Whole House1 1854 10 DHW Sys 1 n/a OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) Front Wall Whole House R-21 Wall 90 Front 600 66.4 90 Left Wall Whole House R-21 Wall 180 Left 500 62 90 Rear Wall Whole House R-21 Wall 270 Back 600 52 90 Right Wall Whole House R-21 Wall 0 Right 500 56 90 Roof Whole House R-08 Roof Attic n/a n/a 1854 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Whole House Attic RoofWhole House VentilatoA 0 0.5 J 0.75 Yes Yes Registration Number: 418-P010034051A-000-000-0000000-0000 Registration Dateffime: 05/23/2018 12:38 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2018-05-18 12:53:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 12:53, Fri, May 18, 2018 Calculation Description: Title 24 Analysis Input File Name: Marcus Residence 53-125 Avenida Ramirez.ribd16x CF1 R-PRF-01 Page 4 of 8 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading Window Window Front Wall (Front-90) - - 1 7.5 0.40 0.26 Insect Screen (default) Window Window Front Wall (Front-90) - - 1 3.0 0.40 0.26 Insect Screen (default) Window 3 Window Front Wall (Front-90) - - 1 33.4 0.40 0.26 Insect Screen (default) Window 4 Window Front Wall (Front-90) - - 1 7.5 0.40 0.26 Insect Screen (default) Window 5 Window Front Wall (Front-90) - - 1 3.0 0.40 0.26 Insect Screen (default) Window 6 Window Front Wall (Front-90) - - 1 12.0 0.40 0.26 Insect Screen (default) Window 7 Window Left Wall (Left-180) - - 1 25.0 0.40 0.26 Insect Screen (default) Window 8 Window Left Wall (Left-180) - - 1 25.0 0.40 0.26 Insect Screen (default) Window 9 Window Left Wall (Left-180) - - 1 4.0 0.40 0.26 Insect Screen (default) Window 10 Window Left Wall (Left-180) - - 1 4.0 0.40 0.26 Insect Screen (default) Window 11 Window Left Wall (Left-180) - - 1 4.0 0.40 0.26 Insect Screen (default) Window 12 Window Rear Wall (Back-270) - - 1 40.0 0.40 0.26 Insect Screen (default) Window 13 Window Rear Wall (Back-270) -- - 1 12.0 0.40 0.26 Insect Screen (default) Window 14 Window Right Wall (Right-0) - - 1 8.0 0.40 0.26 Insect Screen (default) Window 15 Window Right Wall_.(.Fight-0) - - 1 16.0 0.40 0.26 Insect Screen (default) Window 16 Window Right.WaIVI- fight-0) - - 1 8.0 0.40 0.26 Insect Screen (default) Window 17 Window Right 1i�[all.{Right-0) - - 1 16.0 0.40 0.26 Insect Screen (default) Window 18 Window Right Wail4Right-0) - - 1 8.0 1 0.40 0.26 1 Insect Screen (default) OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Cavity/Frame: no insul /2x4 Top Chrd - Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofWhole House Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing. Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-21/2x6 R-21 Wall Exterior Walls Wood Framed -Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. Registration Number: 418-P010034051A-000-000-0000000-0000 Registration Date/Time: 05/23/2018 12:38 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2018-05-18 12:53:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 12:53, Fri, May 18, 2018 Calculation Description: Title 24 Analysis Input File Name: Marcus Residence 53-125 Avenida Ramirez.ribdl6x CF1 R-PRF-01 Page 5 of 8 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area W2) Perimeter (ft) Edge Insul. R-value S Depth Carpeted Fraction Heated Slab -on -Grade Whole House 1854 585 None 1 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 (1) 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Input Rating! Tank Standby Heater Tank Uniform Energy Pilot/ Insulation Loss / First Hour Tank Location Element Number Volume Factor / Energy Thermal R-value Recovery Rating / NEEA Heat Pump or Ambient Name Type Tank Type of Units (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Brand I Model Condition DHW Heater 1 Gas Small Storage 1 1 50 1 0.8 EF 1 46,000 Btu/hr 0 n/a n/a In/a In/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Whole House1 Whole Other Heating and Cooling system Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace 1 80 AFUE Registration Number: 418-P010034051A-000-000-0000000-0000 Registration Date/Time: 05/23/2018 12:38 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2018-05-18 12:53:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 12:53, Fri, May 18, 2018 Calculation Description: Title 24 Analysis Input File Name: Marcus Residence 53-125 Avenida Ramirez.ribdl6x CF1 R-PRF-01 Page 6 of 8 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low4eakage Air Handler Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required Not Required Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed -PSG ce Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 - `' 02 03 Name ' ;Verified Fan Waft Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 Registration Number: 418-P010034051A-000-ODO-0000000-0000 Registration Date/Time: 05/23/2018 12:38 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2018-05-18 12:53:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 12:53, Fri, May 18, 2018 Input File Name: Marcus Residence 53-125 Avenida Ramirez.ribdl6x CF1 R-PRF-01 Page 7 of 8 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 49 0.25 Default 0 Required QUINTA �_L DEPT rtjCTICN Registration Number: 418-P010034051A-000-000-0000000-0000 Registration Date/Time: 05/23/2018 12:38 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 Report Generated at: 2018-05-18 12:53:51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 12:53, Fri, May 18, 2018 Calculation Description: Title 24 Analysis Input File Name: Marcus Residence 53-125 Avenida Ramirez.ribdl6x CF1 R-PRF-01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Joan Hacker J6anNac*er Company: Signature Date: Joan Hacker 05/22/2018 Address: CEA/HERS Certification Identification (if applicable): 72875 Fred Waring Drive City/State/Zip: Phone: Palm Desert, CA 92260 760-345-1352 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Gabriel Rios GabrCaF-'aa Company: Date Signed: Rios Designs 05/23/2018 Address: License: 49-901 Cinnabar Lane City/State/Zip: Phone: Coachella, CA 92236 - -- 760-485-7431 UINTA V`D Y Digitally signed by CHEERSTM. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 418-P010034051A-000-000-0000000-0000 Registration Date/Time: 05/23/2018 12:38 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2018-05-18 12:53:51 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Marcus Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 511812018 Project Address 53-125 Avenida Ramirez La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,854 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity ft) Special Features Status Wall Wood Framed R 21 1,964 Slab Unheated Slab -on -Grade - no insulation 1,854 Perim = 585' New New Roof Wood Framed Attic R 38 1.854 Cool Roof New FENESTRATION I Total Area: 236 Glazirkg Percentage: 12.6% New/Altered Ave a U-Factor: Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades 0.40 Status Front (E) 66.4 0.400 0.26 none none Bug Screen New Left (S) 62.0 0.400 0.26 none none Bug Screen New Rear (M 520 0.400 0.26 none none Bug Screen New Right (N) 56.0 0.400 0.26 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80•/6 AFUE Split Air Conditioner 16 0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status Whole House Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Storage Gas 50 0.60 Standard New Ener_qyPro 72bVEnergySoft User Number: 2655 ID: Pa a 11 of 16 e x1� "s -- t 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply. { ilno nal 08/2016) Building Envelope Measures: § 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft' or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 10l/I.S.2/A440-2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.' § 110 7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8 i when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043 Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.* § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or § 150.0(c): less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly! § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.` § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.31/o; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 11 0.8p . § 150.0(g)1 Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d). § 150.0(g)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58: or the weighted average U-factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e) lA: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)1 B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)1C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control! § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the buildin , are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b) must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.' § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.` Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § I i0.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. _ § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt): and pool ands a heaters Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)1: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; orACCA Manual J using design conditions specified in § 150.0 h 2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the cullel of any dryer vent. § 150.0(h)3B: _ Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.0011: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casinn or sleeve! § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.0013A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause de radation of the material. § 150.0013B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1. 12OV electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a listing a enc that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CIVIC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than A inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such toe is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field4abricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers, _ § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air o enin s and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m 11and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labelin requirements of § 150.0(m)12. _ O*Z��_WJIT 2016 Low -Rise Residential Mandato Measures Summary V Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow ? 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced air systems! Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o). continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference ResidentialAppendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating! § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. § 150.0(p) Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, pi in , filters, and valves' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9 - § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the apgicable r uirements of § 150.0 k ,' Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturers instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5(f); and meets all other requirements in § 150.0(k)2. _ Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 : and all other requirements in § 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used tocomply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.* § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0 k 3A or with the applicable requirements in q 110.9, 130.0. 130.2. 130.4. 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B or § 150.0 k 3D must com& with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the applicable requirements in $110.9. 130.0. 130.2. 130.4. 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)5: _ Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0,130.1. 130.4. 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the III: fullx on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.1 0b through § 110.10 e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.* Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water-heatin s stem. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 1 10.10c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Marcus Residence Date 5/18/2018 System Name Whole House Floor Area 1,854 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 830 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System i 86,000 19,846 1,832 956 34,820 Total Output (Btuh) 86,000 0 Output Btuh/s ft 46.4 1,146 1,711 Cooling S tem 0 0 Output per system 58,000 0 0 0 0 Total Output Btuh 58,000 0 1,146 1 22,137 1,832 0 Total Output Tons 4-8 1,711 Total Output (Btuh/s ft) 31.3 Total Output s ftrron 383.6 38,242 Air S tem CFM per System 2,055 HVAC EQUIPMENT SELECTION Airflow cfm 2,055 York GCGD 60S 415 3A 43,997 5,684 86,000 Airflow cfm/s t 1.11 Airflow cfm/Ton 425.2 Outside Air % 0.0/0 Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 43,997 5,684 Aug 3 PM 86,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions I HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF Outside Air AV- 0 cfm Supply Fan 2,055 cfm 69 OF 69 °F 105 OF rn, 1 Heating Coil �I I 1 I H 4 i 104 OF ROOM 70 IF .1 COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112178 OF 79 ! 63 OF 79 ! 63 °F 55 / 54 °F Outside Air 0 cfm Supply Fan Cooling Coil 2,055 cfm 79/63°F ] 56154 OF �---- 421% ROOM 78/63°F EnergyPro 7.2 by EnergySoft User Number: 2655 ID: Page 16 of 16