Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BRES2018-0309
78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: RICH VAN SANT 12846 GLEN VIEW WAY WHITEWATER, CA 92282 T*'vl 4 1wQ" DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT BUILDING RESIDENTIAL/REMODEL BRES2018-0309 48700 FULL MOON WAY 623470014 WAMPLER / 31.5 SF ROOM ADDITION $6,000.00 PD Q� OCT 29 2018 D VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: JOHN WAMPLER 48700 FULL MOON WAY LA QUINTA, CA 92253 Contractor: OWNER BUILDER Date: 10/29/2018 CITY OF LAOUINTA Llc. No.: --------------------------- pES4GN&DEVELOPMENTDEPARTMENT- ----------------------_----------_---'_- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: ae•. Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit ects the applicant to a civil penalty of not more than five hundred dollars ($500).: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or a did not build or improve for the purpose of sale.). as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.), (_) I am exempt under Sec. B.&P.C. for this reason Date; `iit•d ' �' � Owner: CONSTRUCTION LENDING AGE Y hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Add WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carr' r Policy Number:_ zertify that in the performance of the work for which this permit is issued, I shall hot employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of th bor Code, I shall forthwith comply with those provisions. ', aA Date: - \O Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATIO 11 VERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit, 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. certify that I have read this application and state that the above information is correct. agree to comply with all city and county ordinances and state laws relating to building -onstruction, and hereby authorize representatives of this city to enter upon the above - mentioned property for inspection purposes. )_Tate:' L '21 .12 Signature (Applicant or Agent): Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: RICH VAN SANT 12846 GLEN VIEW WAY WHITEWATER, CA 92282 BRES2018-0309 48700 FULL MOON WAY 623470014 WAMPLER / 31.5 SF ROOM ADDITION $6,000.00 Owner: JOHN WAMPLER 48700 FULL MOON WAY LA QUINTA, CA 92253 Contractor: OWNER BUILDER Date: 10/29/2018 Llc. No.: --------------------------------------------t- ----------------- •---------------------------- Detail: 153SF REMODEL OF TWO BATHROOMS, WITH A 31SF ADDITION TO CREATE A NEW MEDIA ROOM. 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $26.01 I Total Paid for ELECTRICAL: 952_o2 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN 101-0000-42402 0 $13.00 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN PC 101-0000-42600 0 $5.20 I Total Paid for MECHANICAL: $18.20 DESCRIPTION ACCOUNT CITY AMOUNT PLAN CHECK DEPOSIT - ADDITION/REMODEL 101-0000-42600 1 $125.00 Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $52.00 DESCRIPTION FIXTURE/TRAP PC ACCOUNT 101-0000-42600 CITY 0 AMOUNT $52.00 Total Paid for PLUMBING FEES: $104.00 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $20.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $20.00 DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, FIRST 100 SF 101-0000-42400 0 $53.05 DESCRIPTION REMODEL, FIRST 500 SF PC ACCOUNT 101-0000-42600 CITY 0 AMOUNT $145.12 I Total Paid for REMODEL: $198.17 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $0.78 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.78 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 PERMIT 4 is ael!b2 off ~ 03 0 PLAN LOCATION: i �. QO � •V Project Address: 46 �� Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: 2iI,.S C .4�f�i �i�r✓ Applieant_Name: Address: City, ST, Zip: Telephone- 76<5 -7.1A-. 06L�,- Email: A r?�z H vA.;�j r��� CDC Valuation of Project $ L b[%C'i0 Contractor Name: OW )E � 00 I L D j_�� 'V u New SFD Construction: Address: Conditioned SpaceSF City, St, Zip Garage SF Telephone: Patio/Porch SF Email: Fire Sprinklers SF State Lie: City Bus Lie: Arch/Eng Name: Construction Type: Occupancy: Address: Grading: NA City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lie: City Bus Lie: t Property Owner's Name: �-1 JS 14V New Commercial / Tenant Improvements: Address: Total Building SF City, ST, Zip G Construction Type: Occupancy: Telephone: A 7 Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 �'r r'r"gl ,� R 'r qy • A OFFICE USE ONLY # Submittal Req'd Req'd Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License STATE OF CALIFORNIA C-, k-T-A Prescriptive Residential Additions That Do Not Require HERS Field Verification CEC-CF1 R-A00102-E Mevised 07/17] CERTIFICATE OF COMPLIANCE Prescriptive Residential Additions That Do Not Require HERS Field Verification PfOfect NRme. Wampler Addition Date Prepared: 9/1/2018 CALlFORNIAEiJERGYCOMM15SION e CF1R-ADD-02-E (Pagel of 9) • • •.I uvr-u,rrcr,t o urrry uppncaoie ro aaamons less than 1, 000ft`and do not require HERS field verification for compliance. When HERS verification is required, a CFIR-ADD-01 shall first be registered with a HERS Provider Data Registry. Alterations to Space Conditioning Systems that are exempt from HERS verification fequirements may use the CFIR-ADD-02 and CF2R- ADD-02 Compliance Documents. Passible exemptions from duct leakage testing include: less than 40 ft of ducts were added or replaced; or the existing duct system was insulated with asbestos; or the existing duct system was previously tested and passed by a HERS Rater. If space conditioning systems are altered and are not exempt from HERS verification, then a CFIR-ADD-01 must be completed and registered with a HERS Provider Data Registry. Additions or alterations that utilize close Cell Spray Polyurethane Foam (ccSPF) with a density of 1.5 to less than 2.5 pounds per cubic fast having an R-value other than 5.8 per inch, or Open Cell Spray Polyurethane Foam (orSPF) with a density of 0.4 to less than 1.5 pounds per cubic fact having an R-value of 3.6 per inch, shall complete and register a CFIR ADD-01 with a HERS Provider Data Registry. If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they are responsible. Alternatively, the person with chief responsibility for construction shall prepare and sign this certificate for the entire construction. All applicable Mandatory Measures shall be met. Temporary labels shall not be removed before verification by the building inspector. A. General Information 01 Project Name: 03 Project Location: 05 CA City: 07 Zip Code: 09 1 Climate Zone: 11 1 Building Type: 13 1 Project Scope Wampler Addition 48700 Full Moon Way La Quinta 15 Single Family Addition: CFA = 31.5 scift CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE CO PLIANCE 02 04 06 08 10 12 14 Date Prepared: Building Front Orientation (deg): Number of Dwelling Units with Additions: Fuel Type: Total Conditioned Floor Area (ft) (Addition): Slab Area (W): Exceptions to Fenestration U-factor and SHGC 150.1(c)3A: 9/1/2018 (NW) 315 deg 1 Natural Gas 31.5 32 RECEIVEC OCT 16 201F Cr Yr OF LA QUINTA COMMONLY DEVLCPMENT CA Building Energy Efficiency Standards - 2016 Residential Compliance � � � July 2017 � �43 � f t- 0 �a9 4 — -1 cV � Q � a �l N STATE OF CALIFORNIA Prescriptive Residential Additions That Do Not Require HERS Field Verification CERTIFICATE OF COMPLIANCE Prescriptive Residential Additions That Do Not Require HERS Field Verification Wampler Addition Date Prepared: 9/ 1 /2 D 1 p IA MISSION r CF1R-ADD-02-E (Page 2 of 9) CA Building Energy Efficiency Standards - 2016 Residential Compliance July 2017 STATE OF CALIFORNIA Prescriptive Residential Additions That Do Not Require HERS Field Verification CEC-CF1R•ADO-02-E [Revised 071171 CERTIFICATE OF COMPLIANCE Prescriptive Residential Additions That Do Not Require HERS Field Verification Name: Wampler Addition Date 9/1 /2018 CF1R-ADD-02-E (Page 3 of 9) C. Opaque Surface Details — Non -framed (Section 150.1(c)1) 01 02 03 04 05 06 07 08 09 10 11 Proposed Required AppendixJA4 Core Continuous Reference Thickness Insulation Tag/ID AssembiyType Assembfy Materials (inches) R-value Insulation R-value U Factorfrom U-Factor Table Cell Package A Comments D. Opaque Surface Details -- Mass Walls (Section 150.1(c)1) I 01 02 03 04 05 06 07 08 09 10 11 Proposed Required Interior Insulation Walls Mass Furring Strip Exterior Insulation AppendixJA4 I Interior Insulation Exterior Insulation Above Thickness Thickness Reference Tag/lD Grade Mass Type (inches) (inches) R-value U-factor R-value U-factor Table Cell i R-value U-factor R-value U-factor f CA Building Energy Efficiency Standards - 2016 Residential Compliance July 2017 STATE OF CALIFORNIA Prescriptive Residential Additions That Do Not Require HERS Field Verification CEC-C F I R-ADD-02- E (Revised 07117) CALIFORHIAPNERGY COMMISSION AD CERTIFICATE OF COMPLIANCE _ CF1R-ADD-02-E Prescriptive Residential Additions That Do Not Require HERS Field Verification (Page 4 of 9) Project Name: Wampler Addition Date Prepared: 9/1 /2018 E. Slab Insulation (Table 150.1-A) 01 02 03 04 05 06 Floor Type Proposed Required Comments Insulation R-value Insulation LI-factor Insulation R-value Insulation U-factor Unheated Slab -on -Grade 0 0.730 Note: • Heated slab floors require mandatory slab insulation (see Table 110.8-A). F. Radiant Barrier (Section 150.1(c)2) 01 02 Radiant Barrier installed below the roof deck and on all gable end walls Comments All New Roof areas with Attics Radiant Barrier required in this Climate Zone I 1 A radiant barrier is required (for Climate Zones 2-15) • Radiant barriers shall meet specific eligibility and installation criteria to receive energy credit for compliance with the Building Energy Efficiency Standards for low-rise residential buildings. Refer to RA4.2.1 • The emittance of the radiant barrier shall be less than or equal to 0.05 as tested in accordance with ASTM C1371 or ASTM E408. • For Prescriptive Compliance the attic shall be ventilated to provide a minimum free ventilation area of not less than one square foot of vent area for each 300 ft2 of attic floor area with no less than 30 percent upper vents. Ridge vents or gable end vents are recommended to achieve the best performance. The material should be cut to allow for full airflow to the venting. CA Building Energy Efficiency Standards - 2016 Residential Compliance July 2017 STATE OF CALIFORNIA Prescriptive Residential Additions That Do Not Require HERS Field Verification Nu . CEC-CF7R-ADD-02-E (Revised 07f17)_ CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ADD-02-E Prescriptive Residential Additions That Do Not Require HERS Field Verification (Page 5 of 9) Project Name; Wampler Addition Date Prepared' 9/1/2018 G. Roofing Products (Cool Roof) (Section 150.1(c)11) 01 02 03 04 05 06 07 08 09 1 10 11 12 Mass Roof 25lb/ft2 or Greater Roof Pitch Method of Compliance Product Type CRRC Product ID Number Proposed Required Initial Solar Reflectance Aged Solar Thermal Reflectance Emittance SRI (Optional) Aged Solar Thermal Reflectance Emittance SRI (Optional) 1 � I 1 I ' Notes: • Any roof area covered by building integrated photovoltaic panels and solar thermal panels are exempt from the above Cool Roof requirements. ■ Liquid field applied coatings must comply with installation criteria from section 110.8(i)4. H. Fenestration/Glazing Allowed Areas and Efficiencies (Section 150.2(a)1) 01 02 03 04 1 05 06 07 08 09 10 Maximum Allowed Maximum Allowed Fenestration Area for All West -Facing Fenestration Orientations ftZ Area Only ftZ Maximum Maximum Maximum Maximum The Greater The Greater Addition Allowed Allowed Allowed Allowed Type ftZ LI-factor LI-factor SHGC SHGC Comments Maximum Maximum Calculated Maximum Calculated Maximum (Windows) (Skylights) (Windows) (Skylights) based on Calculated based on Calculated Allowed ft Allowed ft Allowed % Allowed % i 31.5 9.5 75.0 60.0 60.0 0.320 0.550 0.250 0.300 Skylight Exception <= 16 scift CA Building Energy Efficiency Standards - 2016 Residential Compliance July 2017 STATE OF CALIFORNIA Prescriptive Residential Additions That Do Not Require HERS Field Verification CEC-CFIR-ADD-Oz-E (Revised 0 711 7CALIFORNIA ENERGY COMMISSION 4e CERTIFICATE OF COMPLIANCE CF111-ADD-02-E Prescriptive Residential Additions That Do Not Require HERS Field Verification (Page 6 of 9) Project Name: Warnpler Addition Date Prepared: _ 9/1 /2018 I. Fenestration Proposed Areas and Efficiencies Note: If meeting Exception 1 to 150.1(c)3A, Installing <_ 3ft2 glass in door, it is assumed to meet the minimum required U-factor (0.32) & SHGC (0.25). If meeting Exception 1 to 150.1(c)3A, Installing 5 3ft2 tubular skylight, it is assumed to meet the minimum required U-factor (0.55) & SHGC (0.30). 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Tag/I Orientation Number Proposed Proposed Fenestration D namic p Y West Facing Proposed Proposed Frame Type N, S, W, E Fenestration Exterior Combined D Type Glazing of Source Source Fenestration U-factor SHGC Shading SHGC from panes Area ft2 Area ft Device CF1R ENV-03 1 New Non -Metal (NW) 2 40.0 40.0 i 0.320 NFRC 0.25 NFRC i n/a 0.25 15 Total Proposed Fenestration Area 40.0 16 Maximum Allowed Fenestration Area 75.0 17 Compliance Statement Total Proposed Fenestration Area <_ Maximum Allowed Fenestration Area ❑ Yes ❑ No 18 Total Proposed West -Facing Fenestration Area 40.0 19 Maximum Allowed West -Facing Fenestration Area 60.0 20 Compliance Statement I Total Proposed West -Facing Fenestration Area 5 Maximum Allowed West -Facing Fenestration Area 0 Yes ❑ No 21 Proposed Fenestration U-factor (Windows) 0.320 22 Required Fenestration U-factor (Windows) 0.320 23 Compliance Statement Proposed Fenestration U-factor 5 Required Fenestration U-factor 0 Yes ❑ No 24 Proposed Fenestration SHGC (Windows) 0.250 25 Required Fenestration SHGC (Windows) 0.250 26 Compliance Statement I Proposed Fenestration SHGC 5 Required Fenestration SHGC 0 Yes ❑ No 27 Proposed Fenestration U-factor (Skylights) 0.000 28 Required Fenestration U-factor (Skylights) 0.550 29 Compliance Statement Proposed Fenestration U-factor 5 Required Fenestration U-factor 0 Yes ❑ No 30 Proposed Fenestration SHGC (Skylights) 0.000 31 Required Fenestration SHGC (Skylights) 0.300 32 Compliance Statement Proposed Fenestration SHGC 5 Required Fenestration SHGC 0 Yes ❑ No CA Building Energy Efficiency Standards - 2016 Residential Compliance July 2017 STATE OF CALIFORNIA Prescriptive Residential Additions That Do Not Require HERS Field Verification CEC-CFIR•AOD-02-E Revised 07117) CERTIFICATE OF COMPLIANCE Prescriptive Residential Additions That Do Not Require HERS Field Verification Project Name: Wa m P ler Addition Date Prepared: CALIFORNIA ENERGY COMMISSION CF1R-ADD-02-E (Page 7 of 9) 9/1 /20 1 8 J. Space Conditioning (SC) Systems - Heating/Cooling (Prescriptive Section 150.2(b)) Alterations to Space Conditioning Systems shall be exempt from HERS verification requirements as prerequisite for use of the CF111-ADD-02 and CF211-ADD-02 Compliance Documents. If new space conditioning systems are installed or existing systems are altered and are not exempt from HERS verification, then a CF1R-ADD-01 shall be completed and registered with a HERS Provider Data Registry. In each row below for each dwelling unit in the building, check the box that indicates the exemption from HERS verification compliance: ❑ a: space conditioning system was not altered; ❑ b: less than 40 ft of ducts were added or replaced; ❑ c: (exempt from duct leakage testing) if: the existing duct system was insulated with asbestos; ❑ d: (exempt from duct leakage testing) if: the existing duct system was previously tested and passed by a HERS Rater. 01 02 03 04 Dwelling Unit Name SC System Identification or Name SC System Location or Area Served Exemption from HERS Verification Existing System 32 0 a 0 b ❑ c ❑ d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b El ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d ❑a ❑b ❑c ❑d CA Building Energy Efficiency Standards - 2016 Residential Compliance July 2017 STATE OF CALIFORNIA Prescriptive Residential Additions That Do Not Require HERS Field Verification CERTIFICATE OF COMPLIANCE CF1R-ADD-02-E Prescriptive Residential Additions That Do Not Require HERS Field Verification (Page 8 of 9) Project Name: Warnpi.er Addition QMe PreparedL�/'I/�i)�a K. Water Heating Systems (Section 150.2(a)iD) List water heaters and boilers for both domestic hot water (DHW) heaters and hydronic space heating. 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Water Heating System Dwelling Unit Identification or Name Name Water Heating System Location or Area Served Water Heating System Type Water Heater Type # of Water Heaters in System Water Heater Storage Volume (gal) Fuel Type Rated Input Type Rated Input Value Heating Efficiency yp Type Heating Efficiency Value Standby Loss (%) Exterior Insulation R-Value Back -Up Solar Savings Fraction CA Building Energy Efficiency Standards - 2016 Residential Compliance July 2017 STATE OF CALIFORNIA Prescriptive Residential Additions That Do Not Require HERS Field Verification C EC-CF I R-A DO-02-E (Revised 07117) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ADD-02-E Prescriptive Residential Additions That Do Not Require HERS Field Verification (Page 9 of 9) i rrojecr name: Warnpler Addition I Date Prepared: 9/1/2018 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Company: Desert Engineers Signature Date: 9/1/2018 Address: CEA/ HERS Certification Identification (If applicable): City/State/Zip: � Phone: ? 6-0 - C5&0 ` 9&6o RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. S. I will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. A Responsible Designer Name: Res sign re: Rich Van Sant i Company: Date Signed: Address: 12846 Glen View Court License: City/State/Zlp: Phone: Whitewater, CA 1-7 ?air - o6. For assistance or questions regarding the Energy Standards, contact the Energy Hotline at:1-800-772-3300. CA Building Energy Efficiency Standards - 2016 Residential Compliance July 2017 2016 Low -Rise Residential Mandatary Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and ulility rooms, at least one luminatre in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JA8 except luminaires in closets less than 70 square feet and luminaires in hallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.4 k 3A or with the applicable requirements in §§ 110.9,130.0 130.2,130.4,144.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150,4 k 3B or J 150.0 k ❑ must comply wilh the applicable requirements in 110.9 130.0 130.2,130.4, 140.7 and 14U. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the applicable requirements in §§ 110.9,130.0,130.2,130.4,140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of )Lower as determined according to § 130.0 c . § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the requirements for nonresidential garages in §§ 110.9,130.0, 130.1 1304,140.6, and 141.0. -applicable Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)68: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 rcent. The occupant sensors must be ca able of lu rn! ng the light full y on and off from all designed paft of ing ress and egress - Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1. application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.10(b) through § 110.10(e). § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) Irough § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply wfth access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1. greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of time total roof area of the building excluding any skylight area_' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof § 110.10(b)3A: mounted equipment' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)313: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical are.' Structural Design Loads on Construction Documents. For areas - the roof designated as solar zone, the structural design loads for roof § 110.10(b)4: dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be time main service panet); and a pathway for rouUng of p lumbi ng from the solar zone to the water -heats ng system. Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(d): 110.10 c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as 'For Future Solar Electric". �` 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems [hat use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure prone (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RAU. This applies to both single zone central forced air systems and every zone for zonally controlled central forced air systems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic lesting, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating' § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 1104(b)3: Directional inlets and time switches for pools. Poois must have directional inlets chat adequately mix the pool wafer, and a lime switch that will allow all Dumas to be set or nrourammed to run only du6no off•neak electric demand oerinds. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. § 150.0(p): Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements Of § 110.9.' § 110.9(e): JAB High Efficacy Light Sources. To qualify as a JAB high efficacy light source for compliance with § 150.0(k), a resid"al light source must be certified to the Energy Commission according to Reference Joint Appendix JAB. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1 C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downlight luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacangy sensors. _ § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable icable requirements of 150.0(k).' Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JAB-2016" or "JA8-2016-E" as specified in Reference Joint Appendix § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JAB compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with R IRA AN% § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130. ; and meets all other requirements in J 150.0 k 2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5(9; and all otherrequirentonis in § 150.6',k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionali€y of a dimmer according to § 110=9. and complies with all other applicable requirements in § 150.0(k)2- G2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systerns, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value 1s indicated on the exterior of the tank. Water piping and cooling system tine insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be Insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures' § 150.00)2B: Water piping and tooting system line insulation. All domestic hot water pipes that are burled below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system tines must be insulated as specified in § 150.00)2A. DIstribuiton pipingfor steam and h dronlc heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection, Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)l : 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -healing systems and collectors must be cerlified and rated by the Solar Rating and Certification Corporation SRCC or by a list agency that is approved the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writi, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC % 601.0, 602.0, 603.0, 604.0, 605.0 and AN$VSMACNA-006-2006 HVAC Duct Construction Standards Mete and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723, If mastic or tape is used to seal openings greater than %inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cress -sectional area of the ducts: Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. _ § 150.0(m)3: Field -Fabricated Duct System. Field -fabricated duct systems must comply with applicable requirements for. pressure -sensitive tapes, mastics, sealants and other requirements specified for duct construction. Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or § 150.0(m)7: automatic dam § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually o rated dampers in all o eni s to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or § 150.0(m)9: plastic cover. Cellular foam insulation must be protected as above or painted with a coaling that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m l land Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and la beling req uiremenis of J 150.0 m 12. ..y, r 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply. iRevised 04/2017] Building Envelope Measures: § 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm9ft2 or less when tested per NFRC-400 or ASTM E283 or AAMAIWDMA/CSA IOl/I.S.2/A440-2011.- § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-8 for compliance and must be caulked and/orweatherstri § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8 i when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a dDTail ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U- § 150.0(c): factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly." § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.' § 150.0(9: Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.30/6, have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor, meet the requirements of § 11 0.8. Vapor Retarder. In Climate Zones 1-16. the earth floor of unveoted crawl space must be covered with a Class I or Class II vapor retarder. This § 150.0(g)1: r uirement also applies to controlled ventilation aawi space for buildin s complying with the exce Lion to § 160.0(d). Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all § 150.0(g)2: insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-#actor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58 : Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)lA: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is a ui ed with a readily accessible, operable. and tight-fittingtight-fitling damper or combustion -air control device.' § 150.0(e)1C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building. are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.* § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K : Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.* § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § f 10.3 c 5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fit6n s on both cold water and hat water lines of water heating system to allow for water lank flushin when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot lights that consume less than 150 8tumr are exem and pool and spa heaters: Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions 5 ified in § 150.0(h)2. CERTIFICATE OF COMPLIANCE 0%yteo Desert Sands Unified School District `'AilAWA °c 47950 Dune Palms RoadBEWupAtn,W'' wwcuc AIur+nrgr $ r war�.x WElea q Date: 10/11/2018 La Quinta, CA 92253 No.: 18-01140-1 (760)771-8515 - Owner: John Wampler Email: Address: 48700 Full Moon Way Jurisdiction: La Quinta City: La Quinta Tract #: Type: Residential Addition < 500 sq ft Lot # Street No. Street Name Sq. Feet APN Permit No. 48700 Full Moon Way 31 623-470-014 Comments: At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation} or replacement mobile homes. It has been determined that the above -named owner is exempt from paying school fees atthis time due to the following Reason: Residential Addition 500 Sq Feet or Less Exempt This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 31 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: Exert t Ri r V ant Check No.: Bank Name/Recipient of Certificate Telephone: 760-774-0653 Funding: Residential By Scott L. Bailey Superintendent Fee Collected/ Exempted by: Rodney Slagle Certificate Fees Due: $0.00 Original Payment(s) Rec'd: $0.00 New Payment Rec'd: $0.00 Over/Under: $0.00 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90•day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. Building Permit Number: Project Description: small room addition ~Exempt.. a erials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Plan Submittal Date 10/5/2018 Job Site Address I 48700 Full Moon Way Owner's Name John & Kim Wampler Number, Street, or PO Box 48700 Full Moon Way City, State, Postal Code La Quinta, CA. 92253 Owner's Phone Number c/o 760-774-0653 Owners E-Mail Address Project Managers Namel Rich Van Sant Project Managers Phone Number 760-774-0653 Project Manager's Email Address adrichvansant rnail.co Builder/Contractor Rich Van Sant Number, Street or PO Box 12846 Glenview Ct City, State, Postal Code Whitewater, CA. 92282 Project Square Footage Approx. 31 sq ft City Approval By Renado Gouldlock-DEC/Burrtec Waste' Date of City Approval FO Materials To Be Discarded: Product Tons Trash 0.15 Not recyclable Asphalt 0.00 Recyclable Brick/Block 0.00 Recyclable Cardboard 0.00 Recyclable Commingled 0.00 Recyclable Concrete 0.15 Recyclable Drywall 0.02 Recyclable Donated / Reuse' 0.00 1 Recyclable "Describe Items [� Totals: Recy"I Trash C 0.31 L_0.2I Product Tons Masonry (broken) 0.00 Plaster 0.04 Scrap Metal 0.00 Tile (floor) 0.01 Tile (root) 0.01 Wood 0.05 Landscape Debris 0.00 Projected Diversion: _ F65.12% I understand It is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property ow (s) and general contractor shall be kept informed of the diversion progress through bi- nthly fort if-ha� II f material from this project site must be taken to an approved recyder or transfer to i� nerl Developer Pro ct Manager l S pe ntendent paw HIDDEN CANYON HOMEOWNERS ASSOCIATION ARCHITECTURAL AND LANDSCAPE DESIGN REVIEW APPLICATION FORM Some applications, approval may take up to thirt 30days. Owner's Name: IN AV[I Date: { o - 1 l - to Hidden Canyon Address: `] 00 rry LA, "o0i1 L Mailing Address: — Phone: -7f) - ]Q-• !P& S 3 ` Projected Start Date: t©.' I - l 8 A r> �1[rt (��SG`1 I;ArjT E-mail Address: Projected Completion Date: Detailed Description of Modification: For Landscape Approvals provide the following information if applicable: 1. A plan with 1/8" = V- 0" scale, north arrow. 2. DG color and size or other ground cover information. 3. Stepping stone or paver type, size and color information. 4. Stepping stone size and material type. 5. Latin and common plant names, size and quantity. 6. Show planting plan with five year diameter of proposed plant material. 7. Boulder and or river cobble color and size. If cobble is used for drainage purposes, provide drainage information. 8. Lighting manufacturer name and fixture type with bulb wattage. Contractor's Name: Contractor's License Number: Contractor's Telephone Number: CONDITIONS OF APPROVAL AND DISCLAIMER 1. The applicant agrees that all work performed must be in substantial compliance with the plans as approved by the ARC. In the event that any work performed is not in substantial compliance with approved plans, the applicant understands that he/she may be required to correct, alter, and/or remove the non -conforming work or improvement(s) as required by the ARC, and will be responsible for any and all costs associated therewith. 2. No materials may be stored in the street or HOA common areas at any time. 3. Construction hours are: Monday through Saturday 7:OOAM to 5:OOPM 4. Any dirt/debris in the street must be removed and washed clean every day. 5. The Owner will be responsible for any damage to the common areas (including streets) caused by the contractor during construction. PLEASE NOTE THAT THE APPROVAL OF THE PROPOSED PLANS BY THE ASSOCIATION DOES NOT CHANGE OR ABROGATE THE APPLICANT'S OBLIGATION TO OBTAIN ALL NECESSARY PERMITS AND/OR COMPLY WITH ALL APPLICABLE GOVERNMENTAL REGULATIONS, AND IDENTIFY OR COMPLY WITH INDIVIDUAL PROPERTY LINES. An architectural deposit of $1,500 is required for projects in the rear yard i.e., pools, spas, landscaping, room additions, patio covers, barbeque, etc. Front yard installations i.e., gates, walkways, landscaping, walls, driveways, etc. require a deposit if $500.00 at the time of submittal for projects under $3000 in cost and $1500 for projects over $3000. The deposit is refundable after the final inspection of the project by a member of the ARC once it has been determinedthat no damage was caused to the common areas. cry- Ik- 1$ "FOR ASSOCIATION USE ONLY" Additional Conditions of Approval: Your architectural request was approved as submitted. Please ensure your vendors follow the rules and regulations of the association. Architectural Committee: Date: 10/15/18 ( X ) Approved ( ) Denied Denied/further modifications to design are needed 2 -11 11 rr-weol-01-- -