BSOL2018-0012T4ty/ VOICE (760) 777-7125 78-495 CALLE TAMPICO U FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 10/8/2018 Permit Type/Subtype: SOLAR/RESIDENTIAL LESS THAN 10KW Owner: Application Number: BSOL2018-0012 JUANITO A GO / NIEVES G GO Property Address: 47970 VIA JARDIN 47970 VIA JARDIN m APN: 643130040 LA QUINTA, CA 92253 En - Application Description: GO / 8.2kW PV SYSTEM - (30) 275W PANELS+P320 OPT/(1) INV GI) �J Property Zoning: 90 Application Valuation: $30,000.00 c-, o C-5 C) ---I Applicant: Contractor: o FREEDOM FOREVER LLC FREEDOM FOREVER LLC rn z c o0 43445 BUSINESS PARK DR STE 110 43445 BUSINESS PARK DR STE81 ru 0 TEMECULA, CA 92590 TEMECULA, CA 92590 M n oo A (951)239-4161 Llc. No.: 1029644 M 2E --------------------------------------------------------------------------------------------- 4 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B. C10, C46, C39 License No.: 1029644 i` Date: l Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). () I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name_ Lender's Address:__ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of tf�q work for which this permit is issued. tj I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: CALIFORNIA INSURANCE COMPANY Policy Number: 822796610101 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: i f l/ o/ 14 Applicant:' Ll WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. L Date: Signature (Applicant or Agent) _� Date: 10/8/2018 Application Number: BSOL2018-0012 Property Address: 47970 VIA JARDIN APN: 643130040 Application Description: GO / 8.2kW PV SYSTEM - (30) 275W PANELS+P320 OPT/(1) INV Property Zoning: Application Valuation: $30,000.00 Applicant: FREEDOM FOREVER LLC 43445 BUSINESS PARK DR STE 110 TEMECULA, CA 92590 Owner: JUANITO A GO / NIEVES G GO 47970 VIA JARDIN LA QUINTA, CA 92253 Contractor: FREEDOM FOREVER LLC 43445 BUSINESS PARK DR STE 110 TEMECULA, CA 92590 (951)239-4161 LIc. No.: 1029644 --------------------------------------------------------------------------------------------- Detail:-8.2kW SOLAR PRAY - (30) 275kW CANADIAN SOLAR PANELS WITH P320 50LAREDGE OPTIMIZERS AND (1) SOLAREDGE 5E7600H-US INVERTER [540SF] 2016 CALIFORIVIA ELECTRICAL CODE. DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $2.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 DESCRIPTION ACCOUNT QTY AMOUNT PV SYSTEM LESS THAN 10KW 101-0000-42403 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT PV SYSTEM LESS THAN 10KW PC 101-0000-42600 0 $26.01 Total Paid for ELECTRICAL: 952.02 DESCRIPTION ACCOUNT CITY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $98.83 Total Paid for PERMIT ISSUANCE: $98.83 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 * �+ PERMIT PLAN LOCATION: Project Address: LJ. -� q 70 Ue %rC4 Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN ern 4 4 Applicant Name: 0CLJl �'�r�.c {� f Q Ca, A) Address: Y 3i Ar-5-s City, ST, Zip: Telephone: Cf --TEmail: Valuation of Project $ (, -OO O Property Owner's Name: lV f LeU Address: City, ST; Zip T 'eP-t to 6L( Telephone: 7 o -' 2,i- p a 0 Email: New Commercial / Tenant Improvements: Total Building SF Construction Type: Occupancy: u 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal Req'd Req'd Plan Sets Structural Calcs Truss Cales Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License Current Renewables Engineering Structural Calculation for PV Installation Date: 9/12/2018 Job Address: 47970 Via Jardin La quinta, CA 92253 Job Name: Go, Nieves Job Number: 1803 Scope of Work These calculations are for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Table of Content Sheet 2 Structural Geometry, Wind Load, and attachment Checks 3 Live Load, Dead Load, and Roof Framing Checks 4 Seismic Check and Scope of work Engineering Calculations Summary Code 2016 California Building Code R' k is category II Roof Dead Load Dr 20 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 0 psf Wind Load (component and Cladding) V 130 mph Exposure B Seismic Ss 1.500 S1 0.560 References Sincerely, DATE 10 560tb BY GgblAp&S .pp12 1 California Residential Code, 2016 2 NDS for Wood Construction, 2015 3 NDS Supplement, 2015 4 ASCE 7-10 Minimum Design Loads for Buildings and Other Structures 5 AWC SDPWS, 2015 Eugene Munyanziza, P.E. Civil Engineer RECEIVED SEP 20 2018 CTY of LA WWA DESIGN AND DEVELOPMENT DEPARTMENT 19435 Fortunello Ave, Riverside CA 92508/ Phone: 951.254.5655/ Email: Projects@currentrenewableseng.com Wind Load Risk Category = II ASCE 7-10 Table 1.5-1 Wind Speed (3s gust), V = 130 mph ASCE 7-10 Figure 26.5-1A Roughness = B ASCE 7-10 Sec 26.7.2 Exposure = 8 ASCE 7-10 Sec 26.7.3 Topographic Factor, KZT= 1.00 ASCE 7-10 Sec 26.8.2 Ridge Height = 15.0� ft Eave Height = 8.0 ft Mean Roof Height, h = 13.0 ft Roof Angle = 23.0 Degrees Adjustment Factor, A = 1 ASCE 7-10 Figure 30.5-1 Buidling Width = 51.8 ft Building Length = 103 ft a = 3.20 ft ASCE 7-10 Figure 30.5-1 Where a: 10% of least horizontal dimension or 0.4h, whichever is smaller, but not less than 4% of least horizontal dimension or 3ft (0.9m) 11-1:" fn '.- Zone 1 (psf) Pnet30= -25.2 Pnet = 0.6 x A x KZT x Pnet30)= 15.12 Down ! essure ❑.6W Zone 1 (psf) Pnet30= 12.4 Pnet = 0.6 x A x KZT x Pnet30)= 7.44 Rafter Attachments: 0.6D+0.6W CD=1.6 Lag Screw Connection 5/16" Lag Screw Withdrawl Value= Lag Screw Penetration= Prying Coefficient All Zone 2 (psf) Zone 3 (psf) -35.6 -56.2 Figure 30.5-1 21.36 33.72 Equation 30.5-1 Zone 2 (psf) Zone 3 (psf) 12.4 12.4 Figure 30.5-1 7.44 7.44 Equation 30.5-1 266 lb/in Table 12.2A - NDS 2.5 in DFL assumed 1.4 owable Capacity with CD= 760 lb 0.6D+0.6W Dpv+0.6W Zone Trib Width Area (ft) Uplift (Ibs) Down (Ibs) 1 6 12.6 167.8 131.5 2 6 12.6 246.5 131.5 3 3.20 6.7 214.5 70.2 Max= 246.5 < 760 CONNECTION IS OK I. Pv seismic dead weight is negligible to result in significant seismic uplif, therefore the wind uplift governs 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. 19435 Fortunello Ave, Riverside CA 92508/ Phone: 951.254.5655/ Email: Projects@currentrenewableseng.com 2 Current Renewables Engineering Vertical Load Resisting System Design Roof Rafter 1(1311-1) Module high 1 a= 0.333 Max Length, L = 7.0 ft Tributary Width, WT= 24 in Dr = 20 psf Lr = 20 psf AISC Table 3-22a f 12 3 fte r m a x I m is m P44fAv-dtbJ#. HO [ 5j��i�) Load Case: 0.5DL+0.6W [CD=1.6) Pup = Pnet x At + 0.6 x PD x cos(6)= 246 lb Mwind_up (aPL)= 574 lb-ft Mallowable = Sx x Fb' (wind)= 684 lb-ft > Load_ Case: DL+0.6W [CD=1.6 40 plf Uplift 574lb-ft OK Pv Point Load 131.5 pif Down Mpv_down (aPL)= 307 lb-ft AISC Table 3-22a Pv max Shear 131.5 Ibs Max Moment, Mu=wL2/8 +Mpv= 552 lb-ft Conservative Max Shear, Vu=wL/2+Pv Point Load = 272 lb Load for deflection= 22.5 psf < Dr+Lr= 40 psf OK (Deflection is "OK" given that current Loading is greater than proposed Loading) Member Capacity DF-L No.2 2X4 Design Value CL CF C, Cr KF X Adjusted Value Fb = 900 psi 1.0 1.5 1.0 1.15 2.54 0.85 0.8 2681 psi Fv = 180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 311 psi E = 1600000 psi N/A N/A 1.0 N/A N/A I N/A N/A 1600000 psi Emin = 1 580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 867680 psi ueptn, a = 3.5 In Width, b = 1.5 in Cross-Sectonal Area, A = 5.25 in' Moment of Inertia, Ixx = 5.35938 in Section Modulus, S,x = 3.0625 in Allowable Moment, Man = Fb'Sxx = 684.3 lb-ft Allowable Shear, Vail = 2/3Fv'A = 1088.6 lb DCR=M„/Mai, = 0.81 < 1 Satisfactory DCR=Vu/Vali = 0.25 < 1 Satisfactory 19435 Fortunello Ave. Riverside CA 92508/ Phone: 951.254.5655/ Email: Projects@currentrenewableseng.com 3 Current Renewables Engineering 5iesmic Loads Check Roof Dead Load 20 psf % or Roof with Pv 38% Dpv and Racking 3 psf Averarage Total Dead Load 21.1 psf Increase in Dead Load 5.7% OK The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on information in the drawing set titled PV plans -Go, Nieves dated (09-01-2018). The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. 19435 Fortunello Ave, Riverside CA 92508/ Phone: 951.254.5655/ Email: Projects@currentrenewableseng.com PHOTOVOLTAIC SYSTEM PV SYSTEM SUMMARY: 8.250 KW CITY NOTES: 1� SITE LOCATION: �A ROOF MOUNT RESIDENTIAL PHOTOVOLTAIC SYSTEM THIS PROJECT COMPLIES WITH THE FOLLOWING: 2016 CALIFORNIA BUILDING CODE (CBC) SYSTEM SIZE (DC) STC: 30 X 275= 8250W DC 2016 CALIFORNIA ELECTRICAL CODE (CEC) oo rr 2016 CALIFORNIA FIRE CODE (CFC) CM �,r;p PTC: 30 X 251.70 = 7551.00W DC 2016 CALIFORNIA PLUMBING CODE �,so'j tdia r rcirce vr, Fiorencc SYSTEM SIZE CEC-AC o 2016 CALIFORNIA MECHANICAL CODE n r ( ) 30 X 251.70 X 98 /o = 7399.98W AC S2016 CALIFORNIA ENERGY CODE MODULES 30 X CANADIAN SOLAR CS6K-275P, 275W 2016 CALIFORNIA RESIDENTIAL CODE + LL < ` 4 2016 CALIFORNIA ADMINISTRATIVE CODE u INVERTER SOLAR EDGE SE760OH-US [S11] AS ADOPTED BY CITY OF LA QUIN T 2 a ROOF CONCRETE TILE a ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE /D V±a Jardin TILT 23' PITCH MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR AZIMUTH TO THE SURFACE UPON WHICH THEY ARE MOUNTED j 160 ° VISIBLE PORTIONS OF THE SOLAR PANEL SUPPORT STRUCTURE AND ANY EXPOSED CI 0 r 'LA QUI' •"rk'R RAFTER/TRUSS SIZE 2" X 4" TRUSSES @ 24" O.0 ELECTRICAL CONDUITS, BOXES AND PANELS WILL NOT BE EXPOSED, AND WILL BE BUM 1NG & SAF !DEPT. f7e, . COLORED MATCHED TO EXISTING ROOF OR SURROUNDING HOME.R,�,L° ATTACHMENT TYPE CONCRETE TILE HOOK WITH IRONRIDGE XR10 RAIL MODULES SHALL BE TESTED, LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN F R CPONI S❑TTRUCT OON ACCORDANCE WITH UL 1703. THE FIRE CLASSIFICATION SHALL COMPLY WITH TABLE MAIN SERVICE PANEL EXISTING 200 AMPS MSP WITH 200 AMPS MAIN 1505.1 OF THE CALIFORNIA BUILDING CODE BASED ON THE TYPE OF CONSTRUCTION OF Oq'fE THE BUILDING. CRC SECTION R902.4 N R314 AND SITE LOIN? SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC SECTION INTERCONNECTION BREAKER ON TOP FEED o 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. • OCPD RATING � PV BREAKER TIED INTO MSP — —� RESIDENTIAL BUILDING UNDERGROUND ADDITION OR IMPROVEMENTS SHALL REPLACE HOUSE AERIAL VIEW: 40 AMPS NON -COMPLIANT PLUMBING FIXTURES WITH WATER CONSERVING PLUMBING FIXTURES IN STRINGING ACCORDANCE WITH CGBSC SECTION301.1.1 AND CIVIL CODE 1101.1 AS FOLLOWS: STRING WITH MODULES AND STRING WITH 14 --WATER CLOSETS: 1.6 GPF (GPF= GALLONS PER FLUSH) UTILITY -FAUCETS (ALL INTERIOR) 2.2 ( GPM = GALLIONS PER MINUTE) MODULES IN SERIES IN EACH STRING -URINALS 1.0 GPF -SHOWER HEADS 2.5 GPM f 'J IMPERIAL IRRIGATION DISTRICT (IID) > TABLE OF CONTENTS INSTALLATION NOTES: PV-1 SITE LOCATION AND HOUSE AERIAL VIEW THE PV BREAKER SHALL NOT EXCEED 120% OF THE ALLOWABLE BACK FEED OF THE MAIN n ° SERVICE BUSS RATING. PV-2 SITE PLAN PV WIRE SHALL BE USED ON DC RUNS FOR UNGROUNDED/TRANSFORMERLESS PV-2A ROOF PLAN WITH MODULES LAYOUT INVERTERS. �{ PV-3 ELECTRICAL LINE DIAGRAM INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK.ROOF ROOF MOUNTING DETAILS, ELEC. CALCULATION & EMT CONDUITS ARE ATTACHED TO THE ROOF USING PRESSURE TREATED WOOD IN CASE PV-4 MATERIAL LIST OF COMPOSITE ROOF OR COUNDUIT HANGERS IN CASE OF CONCRETE ROOF PV-5 LABELS � - MODULE LOCATION CLIENT: C-10#1029644 TITLE:SHEET: freedom GO, NIEVES REVISIONS: •'� DATE: 09/01/2018 DESCRIPTION DATE REVISION 47970 VIA JARDIN, DESIGN SITE LOCATION AND FREEDOM FOREVER LLC LA QUINTA, CA 92253 BY. GREG PV-1 43445 Business Park Dr Suite 110, Temecula, CA 92590 (760) 578-0208 HOUSE AERIAL VIEW Tel: (951) 239-3029 Jos No.: FS-09-004 ROOF AREA: 4187.02 SQ FT (E) MAIN SERVICE PAN ROOT (N) 30 CANADI) GI I PROPERTY LINE C�888783 P. ;3D"240 fir , CA CITY OF LA QUIN'� . BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE 8Y -_& 751-4" SITE PLAN SCALE: 1/16" = V-0" ' • freedom IC-10#1029644 r❑ n e v e a FREEDOM FOREVER LLC CLIENT: GO, NIEVES 47970 VIA JARDIN, LA QUINTA, CA 92253 (760) 578-0208 REVISIONS: DATE: 09/01/2018 TITLE: SITE PLAN SHEET: PV-2 DESCRIPTION DATE REVISION DESIGN BY: GREG 43445 Business Park Dr Suite 110, Temecula, CA 92590 Tel: (951) 239-3029 JOB NO.: FS-09-004 __ (N) SOLAR EDGE SE760OH-US [Sill INVERTER (N) AC DISCONNECT (E) MAIN SERVICE PANEL C1, (N) 3/4" OR LARG C FrI E1e11i-1 c°mra°tor N°; CLIENT: �,, ,,' '.!I,'. Y •�� C-10#1029644 freedom F❑ R E V I R FREEDOM FOREVER LLC 43445 Business Park Dr Suite 110, Temecula, CA 92590 Tel: (951) 239-3029 MODULES ROOF AREA STATEMENT ROOF QT, PITCH AZIMUTH ROOF AREA ARRAY AREA 1 30 23° 160° 1423.82 SQ FT 540.76 SQ FT NOTE: O EMT CONDUIT SUPPORTED BY PIPE HANGERS 12" TO 18" AWAY FROM ROOF EDGE O ATTACH CLAMP AT 25% FROM EDGE AND 50% FROM CENTER OF MODULES 3� JUNCTION BOX MOUNTED TO THE RAIL LEGEND: ® CHIMNEY O PIPE VENT FIRE SETBACKS T TYP ,E ACCESS POINTS D_ 24" O.0 (TYP.) CITY OF LA QUID BUILDING & SAFETY DEO ]" -. APPROVED FOR CONSTRUCTION DATE w4 ROOF PLAN WITH MODULES LAYOUT 1 SCALE: 3/32" = V-0" REVISIONS: TITLE: SHEET: GO, NIEVES DATE: 09/01/2018 DESCRIPTION DATE REVISION 47970 VIA JARDIN, DESIGN GREG ROOF PLAN WITH PV-2A LA QUINTA, CA 92253 BY: MODULES LAYOUT (760) 578-0208 JOB No.: FS-09-004 (200A Bus) * (1.2) = 240A Max Rating (120% of Bus) PV Backfeed (40A) + Main Breaker (200A) = (240A = 240A) See 705.12 (D)(2)(3)(b) of 2016 CEC STRING-1 16 CANADIAN SOLAR CS6K-275P, 275W I I _ _ 1 l STRING-2 ! 14 CANADIAN SOLAR CS6K-275P, j 275W I I I I I I I I I I - I I L — — —-- — — — — — — — — ----- IL — 2 - #10 AWG, PV WIRE 1 - #6 GEC, BARE COPPER General Notes : SOLAREDGE P320 POWER OPTIMIZERS JUNCTION BOX 2 - #10 AWG, PV WIRE SOLAREDGE P320 POWER OPTIMIZERS 1. (30) CANADIAN SOLAR CS6K-275P, 275W wired and listed to UL1703 standards 4 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT INVERTER SOLAR EDGE SE760OH-US [S11] AC / CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY RAPID SHUTDOWN SWITCH 60A, AC DC DISCONNECT A— — — — — — — — — — �O — — o 2. SOLAR EDGE SE760OH-US [S11] Inverter with integrated DC Disconnect and Arc Fault Protection. Attached with system electrical specifications and ground fault protected & listed to UL1741 standards. 3. Photovoltaic system ground will be tied into existing ground at main service from DC Disconnect/Inverter as per CEC Sec. 250.166(A). "The Grounding Electrode Conductor shall not be smaller than the neutral conductor and not smaller than 8AWG copper." 4. Equipment operating 150 volts or greater shall only be serviced or replaced by qualified personnel. Field protection may be in the form of conduit, closed cabinet or an enclosure which requires use of tools to open. 5. Solar Photovoltaic System equipment will be installed in accordance with requirements of Art. 690 of the 2016 CEC. 6.Minimum height of conduit above roof to match temperature derating factor. 7.Photovoltaic DC conductors entering the building shall be installed in metallic raceway and shall be identified every 10 feet -- and within 1 foot above and below penetrations of roof/ceiling assemblies, walls, or barriers -- with minimum 3/8-inch-high white lettering on red background read ing:"WARNING: PHOTOVOLTAIC POWER SOURCE" CLIENT: freedom IC-10#1029644 FREEDOM FOREVER LLC 43445 Business Park Dr Suite 110, Temecula, CA 92590 Tel: (951) 239-3029 GO, NIEVES 47970 VIA JARDIN, LA QUINTA, CA 92253 (760) 578-0208 (E) 200A / 2P MAIN BREAKER TO OTHER LOADS 40A / 2P PV BREAKER 3 - #8 AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT (E) 200A MAIN SERVICE PANEL IIm L-------------- UTILITY METER - CONNECT TO EXISTING UFER 8. System Grounding Electrode conductor for PV system to be sized to meet the requirements of CEC 2016 table 250.66, not smaller than #8 CU AWG." 9. If the existing main service panel does not have a ground rod or ufer, it is the pv contractors responsibility install one. 10. Smoke alarms and carbon monoxide detectors will meet the necessary requirements per CRC R314, R315 11. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM. 12.Terminals of the disconnecting means may be energized in the open position. 13. A signage labeled "SOLAR LOADS ONLY" is to be installed on dedicated solar sub panel to be used for PV only. 14. Solaredge inverters are listed to UL1741 and UL1699B standards. 15. Solaredge Optimizers are listed to IEC62109-1 (class II safety) and UL1741 standards. 16. PV system is using continuous grounding method with #6 bare copper wire. REVISIONS: TITLE: DESCRIPTION DATE REVISION DATE: 09/01/2018 DESIGN GREG ELECTRICAL I BY: LINE DIAGRAM JOB No.: FS-09-004 SHEET: PV-3 IRONRIDGE RAIL — TILE HOOK ROOF TILE 2.5" MIN. 5/16" LAG SCREW FRAMING MEMBER TILE HOOK Scale: NTS STRUCTURAL ONL C..ia+Fi..�. Y`.......v.i.. T:I...r"r.F ELECTRICAL CALCULATIONS BACKFEED BREAKER SIZING MAX. CONTINUOS OUTPUT 32A @ 240V 32 X 1.25 = 40.00AMPS 40A BREAKER - OK CEC 705.12 (D) (2) (3) (b) 200 X 1.20 = 240 240 - 200 = 40A ALLOWABLE BACKFEED DE -RATED AMPACITY OF 8AWG CONDUCTOR @ 0.82 TEMPERATURE CORRECTION 50 X 0.82 = 41.00 AMPS - OK Embedment Photovoltaic Panel Mounting Detail Scale: NTS Ith 6" max MATERIAL LIST QTY EQUIPMENT DESCRIPTION OPEN CIRCUIT VOLTAGE (Voc) : 38.OV CANADIAN MAX. POWER VOLTAGE (Vmp) : 31.OV 30 SOLAR SHORT CIRCUIT CURRENT (Isc) : 9.45A CS6K-275P, 275W MAX. POWER CURRENT (imp): 8.88A PTC RATING: 251.7W SOLAR EDGE MAX. DC INPUT VOLTAGE: 350V SE760OH-US [S11 ] MAX. AC OUTPUT VOLTAGE RANGE: 211-240V 1 MAX. AC OUTPUT CURRENT: 32A WITH POWER MAX. AC POWER OUPUT: 760OW OPTIMIZER CEC EFFICIENCY: 98% 1 JUNCTION BOX 60OVDC, NEMA 4X, UL LISTED 1 AC DISCONNECT 600VAC, 60A, NEMA 3R, UL LISTED 1 PV BREAKER 2 POLE, 240V, 40A 50 ATTACHMENTS CONCRETE TILE HOOK 167' RAIL IRONRIDGE XR10 IRONRIDGE XR10 GROUNDING MID 50 MID CLAMPS CLAMPS 20 END CLAMPS IRONRIDGE XR10 END CLAMPS 90, CONDUIT 3/4" OR LARGER EMT CONDUIT CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BYe. - CLIENT: REVISIONS: TITLE: SHEET: C-10#1029644 DATE: 09/01/2018 {..• freedom GO, NIEVES DESCRIPTION DATE REVISION ROOF MOUNTING r 17 r : R 47970 VIA JARDIN, DESIGN GREG DETAILS, ELEC. PV-4 FREEDOM FOREVER LLC LA QUINTA, CA 92253 BY: CALCULATION & 43445 Business Park Dr Suite 110, Temecula, CA 92590 (760) 578-0208 MATERIAL LIST Tel: (951) 239-3029 JOB NO.: FS-09-004 LABELS: LABELS SPECIFICATION: 1. ALL CAPITAL LETTERS 2. MINIMUM 3/8" LETTER HEIGHT 3. ARIAL OR SIMILAR, NON -BOLD 4. WHITE LETTERING IN RED BACKGROUND 5. WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MUST. MEET THIS REQUIREMENT 6. ALL SIGNS SHOULD BE REFLECTIVE CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING 0 WARNING SOURCES WITH DISCONNECTS LOCATED AS SHOWN TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL P o INVERTER EQUIPPED J� WITH RAPID SHUTDOWN AC DISCONNECT 0 MAIN SERVICE PANEL 0 0 O JUNCTION BOX o 30 PV MODULE Q%cideWcowoctn "' CLIENT: freedom IC-10#1029644 F O R E V E R FREEDOM FOREVER LLC 43445 Business Park Dr Suite 110, Temecula, CA 92590 Tel: (951) 239-3029 DISCONNECTION MEANS ALL AC AND DC DISCONNECTS TO BE MARKED AS DISCONNECTING MEANS PER CEC 2016 690.13(B) AC DISCONNECT PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATION INVERTER OUTPUT CONNECTION TO BE INSTALLED AT MAIN SERVICE PANEL PER CEC 2016 705.12 (D) MARKING SHOULD BE PLACED ON ALL INTERIOR AND EXTERIOR PV CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES, EVERY 10 FEET, AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND ALL PV COMBINER AND JUNCTION BOXES. WARNING PHOTOVOLTIC POWER SOURCE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION; TO BE INSTALLED AT DISCONNECTING MEANS PER CEC 2016 690.17 WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE PER CEC690.35(F) WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. GO, NIEVES 47970 VIA JARDIN, LA QUINTA, CA 92253 (760) 578-0208 WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 690.12 COMPLIANT PHOTOVOLTAIC SYSTEM, EQUIPPED WITH RAPID SHUTDOWN DIRECT -CURRENT PHOTOVOLTAIC POWER SOURCE TO BE INSTALLED AT INVERTER PER CEC 690.53 OPERATING CURRENT: 20.62A OPERATING VOLTAGE: 380.00V SHORT-CIRCUIT CURRENT: 30.00A MAX SYSTEM VOLTAGE: 480.00V AC DISCONNECT PHOTOVOLTIC DISCONNECT FOR UTILITY OPERATION WARNING ELECTRIC SHOCK HAZARD CONTACT QUALIFIED SERVICE PERSONNEL FOR ASSISTANCE Nominal Voltage 240 Volts Nominal AC Frequency 60 Hz Maximum AC Power 7600 Watts Maximum AC Current 32 Amps Max.Overcurrent Device 40 Amps Max. Current per Pole 32 Amps REVISIONS: DESCRIPTION I DATE I REVISION CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY DATE: 09/01 /2018 TITLE DESIGN GREG BY: LABELS JOB NO.: FS-09-004 SHEET: PV-5 1,11,filll col+l,lrr�r, /fy NEW H'�yrrp m i Ilwlfa•'•`� CS6K-260 1 265 1 270 1 275 P Canadian Solar's modules use the latest innovative cell technology, increasing module power output and system reliability, ensured by 15 years of experience in module manufacturing, well -engineered module design, stringent BOM quality testing, an automated manufacturing process and 100% EL testing. KEY FEATURES + Excellent module efficiency of up to 16.80 % (III) Cell efficiency of up to 18.8 % ��( CanadianSolar 25 linear power output warranty �0 product warranty on materials years and workmanship *Black frame product can be provided upon request. MANAGEMENT SYSTEM CERTIFICATES* ISO 9001:2008 / Quality management system ves, F High PTC rating of up to ISO/rS 16949:2009 / The automotive industry quality management system 0f T� 91.89 % ISO 14001:2004 / Standards for environmental management system OHSAS 18001:2007 / International standards for occupational health & safety Outstanding low irradiance performance: 96.5 % Q? IP67 junction box for long-term ID67 weather endurance 0- ;aK`is Heavy snow load up to 5400 Pa, wind load up to 2400 Pa PRODUCT CERTIFICATES* IEC 61215 / IEC 61730: VDE lrOV-Rheinland / CE / MCS UL 1703 / IEC 61215 performance: CEC listed (US) UL 1703: CSA / IEC 61701 ED2. VDE / IEC 62716: VDE / Take-e-way LALC f?- °VE c Sus \� -"8r1. Mar - * As there are different ceroflo%ion requirements in different markets, please contact your local CAnadlan Solar sales representative for the specific CoWlicates applicable to the products in the region In which She produces are to be used. CANADIAN SOLAR INC. is committed to providing high quality solar products, solar system solutions and services to customers around the world. As a leading PV project developer and manufacturer of solar modules with over 15 GW deployed around the world since 2001, Canadian Solar Inc. (NASDAQ: CSIQ) is one of the most bankable solar companies worldwide. ENGINEERING DRAWING (mm) Rear View Frame Cross Section A -A 35 F 19x nw d Hold UK Mounting Hole R 4q5 A A .'a a,ndlnc lidr 54' ELECTRICAL DATA I STC* CS6K 260P 265P 270P 275P Nominal Max. Power (Pmax) 260 W 265 W 270 W 275 W Opt. Operating Voltage (Vmp) 30.4 V 30.6 V 30.8 V 31.0 V Opt. Operating Current (Imp_) 8.56 A 8.66 A 8.75 A 8.88 A Open Circuit Voltage (Voc) 37.5 V 37.7 V_37.9 V 38.0 V Short Circuit Current (Isc) 9.12 A 9.23 A 9.32 A 9.45 A Module Efficiency 15.88% 16.19% 16.50% 16.80% Operating Temperature -40*C-+851C Max. System Voltage 1000 V (IEC) or 1000 V (_UL) Module Fire Performance TYPE 1 (UL 1703) or CLASS C (IEC 61730) Max. Series Fuse Rating 15 A Application Classification A _Class Power Tolerance 0 - + 5 W *Under Standard Test Conditions (STC) of irradiance of 1000 W/m', spectrum AM 1.5 and cell temperatureof 2S-C. ELECTRICAL DATA I NOCT* CS6K 260P 265P 270P 275P Nominal Max. Power (Pmax) 189 W 192 W 196 W 199 W Opt. Operating Voltage (Vmp) 27.7 V 27.9 V 28.1 V 28.3 V Opt. Operating Current (Imp) 6.80 A 6.88 A 6.97 A 7.05 A Open Circuit Voltage (Voc) 34.5 V 34.7 V 34.8 V 34.9 V Short Circuit Current (Isc) 7.39 A 7.48 A 7.55 A 7.66 A * under Nominal Operating Cell Temperature (NOR), irradiance of800 W/m', spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s_ PERFORMANCE AT LOW IRRADIANCE Outstanding performance at low irradiance, average relative efficiency of 96.5 % from an irradiance of 1000 W/m2 to 200 W/M2 (AM 1.5, 25*C). The specification and key features described in hues datasheet may deviate sllghlly ano are not guaranteed. Due to an -going innovation, research and product enhancement, Canadian Solar Inc. reserves the right to make any adjustment to the Information described hefeln at any time without notice. Please atways Obtain the roost recent version of the datasheet wh lch shatf be duly incorporated into the binding contract made by the parties governing all leansactions related to the purchase and sate of the products described herein. Caution: For prolesstonal use only_ The installation and handling of fN modules requlm5L prdfesslonal skills and should onfybe performed by qua5ned protessionak. Please read the safety and installation InstrveVans before using the modules. CS6K-270P / I-V CURVES A 10 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1000 W/m' 5°C ■ 00o W/n1� 25-C to 600 WW 45-C fk r� 400 WW 65'C MECHANICAL DATA Specification Data Cell Type Poly -crystalline, 6 inch Cell Arrangement 60 (6x 10) Dimensions 1650x992x4O mm (65.Ox39.1 x1.57 in) Weight 18.2 kg (40.1 Ibs) Front Cover 3.2 mm tempered glass Frame Material Anodized aluminium alloy J-Box IP67, 3 diodes Cable 4 mm2 (IEC)or4 mm2 & 12 AWG 1000 V (UL), 1000 mm (39.4 in) Connector T4-1000V or PV2 series Per Pallet 26 pieces, 5_2_0 kg (1146.4 Ibs) Per container (40' HQ) 728 pieces TEMPERATURE CHARACTERISTICS Specification Data Temperature Coefficient(Pmax) •0.41%/°C Temperature Coefficient(Voc) -0.31 %1°C Temperature Coefficient (Isc) 0.053 % /°C Nominal Operating Cell Temperature 45t2 0C PARTNER SECTION ......................... .w............. ............... »........ ,.n.............. ........... .-.....I CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario N1 K 1 E6, Canada, www.canadiansolar.com, support@canadiansolar.com CANADIAN SOLAR INC. July 2016. All rights reserved, PV Module Product Datasheet V5.51_EN solar=a@ -. SolarEdge Single Phan for North America SE3000H-US / SE380OH-US / SE5000H SE760OH-US 0 lei Optimized installation with HD -Wave technology Record -breaking efficiency integrated arc fault protection for NEC 2011 690.11 and integrated rapid shutdown for NEC 2014 690.12 Extremely smal W High reliability without any electrolytic capacitors UI111NNI, I D — Built-in module -level monitoring wave — Outdoor and indoor installation — Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) — Optional: Self -Sustaining Power - produce up to 1.SkW directly from PV during grid failure USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THENETHERLANDS-UK-ISRAEL-TURKEY-SOUTHAFRICA-BULGARIA www.solaredge,us =@@ S❑Ia,Single Phase Inverters for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US SE3000H- OUTPUT f Rated AC Power Output 3000 Max. AC Power Output 3000 AC Output Voltage Min: Nom.-Max. (183 - 208 - 229) AC Output Voltage Min.-Nom,-Max. (211- 240 - 264) ✓ AC Frequency (Nominal) Maximum Continuous Output Current 208V - Maximum Continuous Output Current 240V 12.5 GFDI Threshold Utility Monitoring, Islanding Protection, Country Configurable Thresholds_ INPUT Maximum DC PowerT 4650 Transformer -less, Ungrounded Maximum Input Voltage Nominal DC Input Voltage Maximum Input Current 208V Maximum Input Current 240V 8.5 Max. Input Short Circuit Current Reverse -Polarity Protection Ground -Fault Isolation Detection Maximum Inverter Efficiency 99 CEC Weighted Efficiency Nighttime Power Consumption SELF-SUSTAINING POWER OUTLET (OPTIONAL) Nominal Output Voltage Maximum Output Power • External Outlet with GFDI ADDITIONAL FEATURES Supported Communication Interfaces Internal RGM support Rapid Shutdown - NEC 2014 690,12 STANDARD COMPLIANCE Safety Grid Connection Standards Emissions INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range DC Input Conduit Size / # of Strings / AWG Range Dimensions with Safety Switch (HxWxD) Weight with Safety Switch Noise Cooling Operating Temperature Range Protection Rating "Fv- other regional seltings please contact SolarEdge support �� pe;bruis on W nunildbil ily �aip�,wnr de-ral'm6lnlm SQ'f US SE380OH-US SE5000H-US SE6000H-US SE760OH-US 3800 5000 6000 7600 VA 3800 5000 6000 7600 VA ✓ - Vac ✓ .' v; Vac 59.3 - 60 - 60.5(1) Hz - 24 - - A 16 21 2$ 32 A 1 A Yes 5900 7750 9300 11800 W Yes 480 Vdc 380 400 VdC 15.5 - Adc 10.5 13.5 16.5 20 Adc 45 Adc Yes 600ke Sensitivity 99.2. % 99 _ <2.S . 150pnr W Yes RS485, Ethernet, ZigBee (optional), Cellular (optional) ANSI C12.20 class 0.5 compliant Automatic Rapid Shutdown UL1741, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 IEEE1547, Rule 21, Rule14 (HI) FCC Part 15 Class B 0.75-1" Conduit / 14-6 AWG 0.75-1" Conduit /1-2 strings / 14-6 AWG 17.7 x 14.6 x 6.8 /450x370x174 in/mm 25,3 / 11.5 Ib / kg < 25 d BA Natural Convection -13 to +140 / -25 to +60(" (-40' F / -40`C option) "F / -C NEMA 313 (Inverter with Safety Switch) solar =a SolarEdge Power Opt Module Add -On For Nortl P320 / P370 / P400 / P405 / P51 PV power optimization at the module -level Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) — Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module -level monitoring — Compliant with arc fault protection and rapid shutdown NEC requirements (when installed as part of the SolarEdge system) — Module -level voltage shutdown for installer and firefighter safety USA -CAN ADA-GERMANY- UK-ITALY-THE NETHERLANDS-JAPAN-CHINA-AUSTRALIA-ISRAEL-FRANCE-BELGIUM-Tt1RKEY-INDIA-BULGARIA-ROMANIA-HUNGARY- www.solaredgeus SWEDEN-SOUTH AFRICA-POLAND-CZECH REPUBLIC solar=@@ SolarEdge Power Optimizer Module Add -On for North America P320 / P370 / P400 / P405 / P505 P320 P370 P400 P405 P505 OPTIMIZER MODEL (for (for higher -power high -power (for 72 & 96-cell (for film (for higher (typical module compatibility) 60-cell 60 and 72-cell modules) modules) modules) ui current modules) modules) INPUT Rated Input DC Powerl'% 320 370 400 405 505 Absolute Maximum Input Voltage 48 60 80 125 83 (Voc at lowest temperature) MPPT Operating Range 8-48 8-60 8-80 12.5-105 12.5.83 Maximum Short Circuit Current (ISC) 11 10.1 14 Maximum DC Input Current 13.75 12.63 ITS Maximum Efficiency 99.5 Weighted Efficiency 98.8 98.6 Overvoltage Category IV OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Maximum Output Voltage 60 85 OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 128x152x36/ 128x152x50/ 128 x 152 x 28 / 5 x 5.97 x 1.1 5x5.97x1.42 5x5.97x1.96 Weight (including cables) 630 / 1.4 750 / 1.7 845 / 1.9 Input Connector MC412' Output Wire Type / Connector Double Insulated; MC4 Output Wire Length 0.95 / 3.0 1.2 / 3.9 Operating Temperature Range .40 - +85 / -40 - +185 Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 l;l Rated STC power of the module Module of up to +5% power tolerance allowed, For other connector types please contact SolarEdge PV SYSTEM DESIGN USING SINGLE PHASE SINGLE PHASE THREE PHASE 206V A SOLAREDGE INVERTER(3)(4) HD -WAVE Minimum String Length P320, P370, P400 8 10 (Power Optimizers) P405 / P505 $ 8 Maximum String Length 25 25 (Power Optimizers) 5700 (6000 with Maximum Power per String SE760OH-US, 5250 6000 SE10000H-US) Parallel Strings of Different Lengths Yes or Orientations �3' For detailed string sizing information refer to: http://wwv4solaredge.com/sites/default/files/string_sizing_na.pdf. I"' It is not allowed to mix P405/P505 with P320/P370/P400/P600/P700/P800 in one string. ISI A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement W Vdc Vdc Adc Adc Adc Vdc Vdc Vdt 128x152x59/ mm/in 5x5.97x2:32 1064/2.3 gr/lb m/ft /'F... THREE PHASE 480V 14 51 D"7 12750 w IRONRIDGE Flush Mount System XR Rails Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance I rating of the existing roof. PE Certified .., .' Pre -stamped engineering letters available in most states. i_ Design Assistant Online software makes it simple to create, share, and price projects. XR10 Rail A low -profile mounting rail for regions with light snow. • 6' spanning capability • Moderate load capability • Clear & black anod. finish UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear & black finish Flash and mount XR Rails with superior waterproofing. • Twist -on Cap eases install • Wind -driven rain tested • Mill & black finish XR100 Rail The ultimate residential solar mounting rail. • 8' spanning capability • Heavy load capability • Clear & black anod. finish Stopper Sleeves Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • 6 different sizes • Clear & black anod. finish Slotted L-Feet ■ Drop -in design for rapid rail attachment. • Secure rail connections • Slot for vertical adjusting • Clear & black anod. finish XR1000 Rail A heavyweight mounting rail for commercial projects. • 12' spanning capability • Extreme load capability • Clear anodized finish Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Bonding Hardware Bond and attach XR Rails to certified attachments. • T & Square Bolt options • Nut uses 7/16" socket • Assembled & lubricated Bonded Splices All rails use internal splices for seamless connections. • Self -drilling screws • Varying versions for rails • Forms secure bonding Microinverter Kits Mount Mls or POs to XR Rails. • Bonds devices to rails • Kit comes assembled • Listed to UL 2703 Flush Standoffs Raise Flush Mount System to various heights. • Works with vent flashing • 4" and 7" lengths • Ships assembled Design Assistant ;;u, NABCEP Certified Training UL 2703 Listed System 20-Year Warranty Go from rough layout to fully Earn free continuing education credits, N/IBCEP `. engineered system. For free. while learning more about our systems. Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. Go to IronRidge.com/design Go to IronRidge.com/training o-800-227-9523 for more information. Version 1.20 FLAT TILE ROOF HOOK [HD+] FOR SIDE MOUNT RAILS Part # Box Quanitity Screw Size 17632 20 Hooks N/A 17633 1 Hook N/A 17636 20 Hooks & 40 Screws 5/16" x 3" 17637 1 Hook & 2 Screws 5/16" x 3" Type 304 Stainless Steel For Side Mount Rails Rev Letter Description Size/Length A Mounting Screw Holes 9mm B Rail Slot Size 10mm x 46mm C Length of Roof Hook 221.32mm D Rail Height From Finished Roof 144.28mm E Thickness 7mm 7mm � n 1 89mm 11 75mm 105" ;38mm 15mm 100" 117.15mm 44mm E I f —�� F 8d 30mm L_ A Part # Box Quantity 15893 20 Flashing Aluminum Flashing 355.60mm 228.60mm 228.60r►sm 75mm 63.50mm 20mm Rev1 5830 Las Positas Road, Livermore, California 94551 13948 Airway Drive, Rock Hill, South Carolina 29732 5830 Las Positas Road, Livermore, California 94551 13948 Airway Drive, Rock Hill, South Carolina 29732 Phone: (844)-671-6045 1 Fax: (800)-689-7975 1 www.solarroofhook.com Phone: (844)-671-6045 1 Fax: (800)-689-7975 1 www.solarroofhook.com SolarRoofHook is a division of Quickscrews International Corp. solarroofhook.com is a division of Quickscrews International Corp. CLASSIFICATION Constructional Data Report (CDR) 1.0 Reference and Address Report Number 101541132LAX-002 Original 22-Ma -2014 Revised: 15-Jan-2016 Standard(s) UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 Applicant IronRidge, Inc. Manufacturer 1 .IronRidge, Inc. Address 1495 Zephyr Ave Hayward, CA 94544 Address 1495 Zephyr Ave Hayward, CA 94544 Country USA Count USA Contact Yann Schwarz Contact Jim Norsworthy Or Dave Taggart Phone (800)227-9523 (510) 225-0973 Phone (707)363-3025 (800) 227-9523 FAX (707) 459-1833 FAX (510) 225-0975 Email yschwarzC7a, arz@ironridge.com Email inorswarth ironrid e.com dta artironrid e.com Manufacturer 2 Precision Die & Stamping, Inc. Address 1704 W. 10th Street Tempe, AZ 85281 Country USA Contact Andy Frola Phone (480) 967-2038 FAX (480) 829-0838 Email andy@i)recisiondie.com Page 1 of 86 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client Intertek's responsi- liability,are limited to the terms and conditions of the agreement Intertek assumes no liability to any party other than to the Client in accordance will, agreement for any loss expense or damage occasioned by the use of this report Only the Client is authorized to permit copying or distribution of this report then only in its entirety Any use of the Intertek name or one of its marks for the sale or advertisement of the tested matenai product or service must firs Report No. 101541132LAX-002 IronRidge, Inc. Page 2 of 86 Issued: 22-May-2014 Revised: 15-Jan-2016 2.0 Product Description Product XR Rails with Integrated Grounding. Brand name IronRidge Roof Mount The product covered by this report is the IronRidge Rails with Integrated Grounding solar roof mounting system. This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized aluminum rails that are roof mounted using aluminum Extruded L Foot brackets. The mounting rails in this report are XRL, XR10, XR100 and XR1000 Rail. All rails have an optional aluminum splice which ties the rails together to extend their length. A grounding strap and stainless steel hardware are required for penetrating the anodized coating of the rails, creating a bonded connection from rail to rail. 304 stainless steel Grounding Mid Clamp and aluminum End Clamps are used to attach and support framed photovoltaic modules to the system. The End Clamps are not used as a grounding means. The Grounding Mid Clamps are installed onto the module frame by using a 18-8 stainless steel serrated T-Bolt and a 18-8 stainless steel Flange Hex Nut that gets screwed onto the rails to a Description specified torque. The retention teeth of the clamp and bolt penetrate the anodized coating of the photovoltaic modules frame and rail to contact the metal, creating a bonded connection from module to module and module to rail. The grounding of the entire system is intended to be in accordance with the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems. Any local electrical codes must be adhered in addition to the national electrical codes. An entire array, regardless of size, is grounded via one grounding lug. The W EEB Grounding Lug is secured to XRL, XR10, XR100 or XR1000 Rail's top slot using stainless steel hex bolt or T-Bolt, flat washer, split lock washer, and nut, tightened to manufacture's specified torque. The WEEB Grounding Lug is intended for use with one solid or stranded copper wire, conductor size 14 AWG though 6 AWG. The Titan Grounding Lug is secured to XRL, XR10, XR100 or XR1000 Rail's side center cavity of rails using stainless steel T-bolt, k-lock nut, star washer, and machine screw. The Titan Grounding Lug is intended for use with one solid or stranded copper wire, conductor size 14 AWG though 4 AWG. Models IR XR followed by 4 Alphanumeric Characters Model Similarity N/A Fuse Rating: 20 A Fire Class Resistance Rating: - Class A for Steep Slope Flush -Mount (Symmetrical) Applications when using Type 1, Type 2 and Type 3, Listed Photovoltaic Module. Ratings - Class A for Low Slope Flush -Mount (Symmetrical) Applications when using Type 1, Type 2 and Type 3, Listed Photovoltaic Module. - Class A for Steep Slope Tilt -Mount ( Asymmetrical) Applications when using Type 1 and Type 2, Listed Photovoltaic Module. - Class A for Low Slope Tilt -Mount ( Asymmetrical) Applications when using Type 1, Type 2 and Type 3, Listed Photovoltaic Module. ED 16.3 15 (1-Jan-13) Mandatory 25800 Commercentre Drive Lake Forest, CA 92630 USA Telephone: 949.448.4100 Facsimile: 949.448.4111 www.intertek.com Test Verification of Conformity In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. !cant Name & Address: Product Description: Ratings & Principle Characteristics: Models: Brand Name: Relevant Standards: Verification Issuing Office: Date of Tests: IronRidge, Inc. 1495 Zephyr Ave. Hayward, CA 94544 XR Rails with Integrated Grounding. Fire Class Resistance Rating: - Class A for Steep Slope Flush -Mount (symmetrical) Applications when using Type 1 and Type 2, Listed Photovoltaic Module. - Class A for Low Slope Flush -Mount and Tilt -Mount (symmetrical and asymmetrical) Applications when using Type 1, Listed Photovoltaic Module. 51-61GD-005, 51-61GD-005B, 51-5000-001, and 51-65-001 N/A UL Subject 2703 (Section 15.2 and 15.3) Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 2, Nov 13, 2012 Referencing UL1703 (Section 31.2) Standard for Safety for Flat -Plate Photovoltaic Modules and Panels, May 20, 2014 Intertek Testing Services NA, Inc. 25800 Commercentre Dr. Lake Forest, CA 92630 08/27/2014 to 01/07/2015 Test Report Number(s): 1101541132LAX-002 This verification is part of the full test report(s) and should be read in conjunction with them. imply product certification. This report does not automatically Completed by: Amar Kacel Reviewed by: Andrew Koretoff Title: PV Engineer Title: Reviewer Signature: Signature: Signature: Date: 01/26/2015 Date: 01/26/2015 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. GFT-OP-11 a (24-MAR-2014) MODULEf. The Tilt Mount System may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, "xxx" refers to the module power rating and both black and silver frames are included in the certification. ®® Modules with 35, 40, or 45mm frames and model identifier aaSM66yyPzz-xxx; where "aa" is CH Astronergy Solar or A; "yy" is either 10 or 12; and "zz" is blank or (BL). Frameless modules with model identifier CHSM6610P(DG)-xxx. Axitec Modules with 35 or 40mm frames and model identifier AC-xxxY/aa-ZZ; where "Y" is M or P; "aa" is 125 or 156_and "ZZ" is 54S, 60S or 72S. Modules with 35 and 40mm frames and model identifier CSbY-xxxZ; where "b" can be 1, 3 or 6; "Y" can Canadian Solar be K, P, U, V, or X; and "Z" can be M, P, AG, MS, PX , M-SD, P-AG, P-FG or P-SD, MS -AG, MS-FG, or MS -SD. Frameless modules with model identifier CSbY-xxx-FG; where "b" can be 3 or 6; "Y" is K, X, or P; and "Z" can be M-FG or P-FG. ET Solar Modules with 35, 40, or 50mm frames and model identifier ET-Y6ZZxxxAA; where "Y" is P, L, or M; "ZZ" is 60 or 72; and "AA" is WB, WW, BB, WBG, WWG, WBAC, WBCO, WWCO, WWBCO or BBAC. Modules with 35, 40, or 50mm frames and model identifier FXS-xxxYY-ZZ; where "xxx" is the module Flex power rating; "YY" is BB or BC; and "ZZ" is MAA1 B, MAA1 W, MAB1 W, SAA1 B, SAA1 W, SAC1 B, i SAC1 W, SAD1 W, SBA1 B, SBA1 W, SBC1 B, or SBC1 W. GCL Modules with 35 and 40mm frames and and model identifier GCL-a6/YY xxx; where "a" can be M or P; and "YY" can be 60, 72, or 72H. GigaWatt Solar Modules with 40mm frames and model identifier GWxxxYY; where "YY" is either PB or MB. Hanwha Solar Modules with 40, 45, or 50mm frames and model identifier HSLaaP6-YY-1-xxxZ; where "aa" is either 60 or 72; "YY" is PA or PB; and "Z" is blank or B. Modules with 32, 35, 40, and 42mm frames and model identifier aaYY-ZZ-xxx; where "aa" can be Q. or B.; "YY" can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, or PEAK DUO; and "ZZ" can be G3, G3.1, Hanwha Q CELLS G4, G4.1, L-G2, L-G2.3, L-G3, L-G3.1, L-G3y, L-G4, L-G4.2, L-G4y, LG4.2/TAA, BFR-G3, BLK-G3, BFR-G3.1, BLK-G3.1, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1, G4/SC, G4.1 /SC, G4.1 /TAA, G4.1 / MAX, BFR G4.1/TAA, BFR G4.1/MAX, BLK G4.1/TAA, BLK G4.1/SC, EC-G4.4, G5, BLK-G5, L-G5.2, or L-G5.2/H.- Heliene Modules with 40mm frames and model identifier YYZZxxx; where "YY" is 36, 60, 72, or 96; and "ZZ" is M, P, or MBLK. Hyundai Modules with 35, 40 and 50mm frames and model identifier HiS-YxxxZZ; where "Y" can be M or S; and "ZZ" can be MI, MF, MG, SG, RI, RG(BF), RG(BK), TI, orTG. Itek Modules with 40 or 50mm frames and model identifier IT-xxx-YY; where "YY" is blank, HE, or SE, or SE72. Modules with 35, 40 and 45mm frames and model identifier JAyyzz-bb-xxx/aa; where "yy" can be M, P, JA Solar M6 or P6; "zz" can be blank, (K), (L), (R), (V), (BK), (FA), (TG), (FA)(R), (L)(BK), (L)(TG), (R)(BK), (R) (TG), (V)(BK), (BK)(TG), or (L)(BK)(TG); "bb" can be 48, 60, 72, 60501 or 72501; and "aa" can be MP, SI, SC, PR, RE, 3BB, 4BB, 4BB/RE, 5BB. Modules with 40mm frames and model identifier JKMYxxxZZ-aa; where "Y" is blank or S; "ZZ" is P, Jinko PP, M; and "aa" is 60, 60B, 60-J4, 6013-J4, 60(Plus), 60-V, 72, or 72-V. Frameless modules with model identifier JKMxxxPP-DV. Modules with 46mm frames and model identifier KYxxxZZ-AA; where "Y" is D or U; "ZZ" is blank, GX, or Kyocera SX; and "AA" is LPU, LFU, UPU, LPS, LPB, LFB, LFBS, LFB2, LPB2, 3AC, 3BC, 3FC, 4AC, 413C, 4FC, 4UC, 5AC, 5BC, 5FC, 5UC, 6BC, 6FC, 8BC, 6MCA, or 6MPA. LG Modules with 35, 40, and 46mm frames and model identifier LGxxxYaZ-bb; where "Y" is A, E, N, Q, S; LG"a" is 1 or 2; "Z" is C, K, T, or W; and "bb" is A3, A5, B3, G3, G4, or K4. Longi Modules with 40mm frames and model identifier LR6-YY-xxxM; where "YY" can be 60, 72, or 72HV,,. Mission Solar Modules with 40mm frames and model identifier MSExxxZZaa; where "ZZ" can be MM, SE, SO or SQ; and "aa" can be 1 J, 4J, 4S, 5K, 5T, 6J, 6S, or 6W. �r Mitsubishi Modules with 46mm frames and model identifier PV-MYYxxxZZ; where "YY" is LE or JE; and "ZZ" is either HD, HD2, or FB. Motech IM and XS series modules with 40, 45, or 50mm frames. Neo Solar Power Modules with 35mm frames and model identifier D6YxxxZZaa; where "Y" can be M or P; "ZZ" can be B3A, B4A, E3A, E4A, H3A, H4A; and "aa" can be blank, (TF), ME or ME (TF). Panasonic Modules with 35 or 40mm frames and model identifier VBHNxxxYYzz; where "YY" is SA or KA; and zz" is 01, 02, 03, 04, 06, 06B, 11, 11 B, 15, 15B, 16, 16B, 17, or 18. Phono Solar Modules with 35, 40, or 45mm frames and model identifier PSxxxY-ZZ/A; where "Y" is M or P; "ZZ" is 20 or 24; and "A" is F, T or U. Prism Solar Frameless modules with model identifier BiYY-xxxBSTC; where "YY" is 48 or 60. REC Solar Modules with 30, 38 and 45mm frames and model identifier RECxxxYYZZ; where "YY" is M, PE, TP, or TP2S; and "ZZ" is blank, BLK, SLV, or 72. Renesola Modules with 35, 40 or 50mm frames and model identifier JCxxxY-ZZ; where Y' is F, M or S; and "ZZ" is Ab, Ab-b, Abh, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, or Db-b. Renogy Modules with 40 or 50mm frames and model identifier RNG-xxxY; where "Y" is D or P. S-Energy Modules with 40mm frames and model identifier SNxxxY-ZZ; where "Y" is M or P; and "ZZ" is 10, or 15. Seraphim Energy Group Modules with 40mm frames and model identifier SEG-6YY-xxxZZ; where "YY" can be MA, MB, PA, PB; and "ZZ" can be BB, WB, or WW. Seraphim USA Modules with 40 and 50mm frames and model identifier SRP-xxx-6YY; where "YY" can be MA, MB, PA, PB, QA-XX-XX, and QB-XX-XX. Sharp Modules with 35 or 40mm frames and model identifier NUYYxxx; where "YY" is SA or SC. Silfab Modules with 38mm frames and model identifier SYY-Z-xxx; where "YY" is SA or LA; SG or LG; and "Z" is M, P, or X. Solaria Modules with 40mm frames and model identifier PowerXT xxxY-ZZ; where Y' can be R or C; and "ZZ" is BX, BY, PX, PZ, WX or WZ. SolarTech Modules with 42mm frames and model identifier STU-xxxYY; where "YY" can be PERC or HJT SolarWorld Sunmodule Plus, Protect, XL, Bisun, Bisun XL, may be followed by mono, poly or duo and/or black or bk; modules with 31, 33 or 46mm frames and model identifier SW-xxx. Stion Thin film modules with 35mm frames and model identifier STO-xxx or STO-xxxA. Thin film frameless modules with model identifier STL-xxx or STL-xxxA._ - J Modules with 35, 40, or 50mm frames and model identifier SE-YxxxZABCDE; where "Y" is B, F, H, SunEdison P, R, or Z; "Z" is 0 or 4; "A" is B, C, D, E, H, I, J, K, L, M, or N; "B" is B or W; "C" is A or C; "D" is 3, 7, 8, or 9; and "E" is 0, 1 or 2. Modules with 35, 38, 40, 46, or 50mm frames and model identifiers OPTxxx-AA-B-YYY-Z Suniva or MVXxxx-AA-B-YYY-Z; where "AA" is either 60 or 72; "B" is either 4 or 5; "YYY" is either 100,101,700,1 B0, or 1 Bi ; and "Z" is blank or B. Modules with model identifier Ab-xxx-YY and standard (G3) or InvisiMount (G5) 46mm frame; Sunpower where "A" is either E, P or X; "b" can be 17, 18, 19, 20, 21, or 22; and "YY" can be blank, NE, BLK, COM, C-AC, D-AC, BLK-C-AC, or BLK-D-AC. 5unpreme. : Frameless modules with model identifier GXB-xxxYY; where "YY" is blank or SL. Suntech Vd, Vem, Wdb, Wde, and Wd series modules with 35, 40, or 50mm frames. Modules with 35, 40 or 46mm frames and model identifier TSM-xxxYYZZ; where "YY" is PA05, PC05, PD05, PA14, PC14, PD14, PE14, or DD05; and "ZZ" is blank, A, A.05, A.08, A.10, A.18, .05, Trina .08, .10, .18, .08D, .18D, 0.82, A.082(II), .002, .00S, 05S, 08S, A(II), A.08(II), A.05(11), A.10(II), or A.18(II). Frameless modules with model identifier TSM-xxxYY; and "YY" is either PEGS, PEG5.07, PEG14, DEGS(II), DEG5.07(II), or DEG14(II), Winaico Modules with 35 or 40mm frames and model identifier Wsy-xxxz6; where "y" is either P or T; and z"" is either M or P. Ymgli Panda, YGE, and YGE-U series modules with 35, 40, or 50 mm frames. (D 2018 IRON RIDGE,• •