Loading...
510544Q MoF•� ENCROACHMENT PERMIT 'PUBLIC WORKS CONSTRUCTION Finance Revenue Code E-1 D Q � 7JUN 0 2006 CITY OF LA QUINTA FINANCE DEPT. For the construction of�public or private curbs, driveways, pavements, sidewalks,. parking lots, sewers, water mains and other like public works improvements in connection with MINOR IMPROVEMENTS and APPROVED SUBDIVISIONS. Subdivision Improvement Permit - Class III Minor Improvement Permit Class IV DATE:June 6, 2006 LOCATION OF CONSTRUCTION (Street address or Description): Mirage of La Quinta TM 32279; 581 West of Madison PURPOSE OF CONSTRUCTION: Onsite street.and storm drain DESCRIPTION OF CONSTRUCTION: See PSN 05208 and PSN 06067 DIMENSION OFINSTALLATION OR REMOVAL: See PSN 05208 and PSN 06067 APPROXIMATE TIME WHEN WORK WILL BEGIN:June 12, 2006 TIME OF COMPLETION:Will provide schedule ESTIMATED CONSTRUCTION COST: $295,266.00 (Including removal of all obstruction, materials,'and debris, backfilling, compaction and placing permanent resurfacing and/or replacing improvements) COMMENTS: 178,601.00 + 116,665.00 = 295,266.00 In consideration of the granting of this permit, the applicant hereby agrees to: Indemnify, defend and save the City, its authorized agents, officers, representatives and employees, harmless from and against any and all penalties, liabilities or loss resulting from claims or court action and arising out of any accident, loss or damage to persons or property happening. or occurring as a proximate result of any work undertaken under the permit granted pursuant to this application. Notify the Administrative Authority at least twenty-four 124) hours in advance of the time when work will be started at (760) 777- 7075. Comply with all applicable City Ordinances, the' terms and conditions of.the permit and alns o the City of La Quinta and to pay for any additional replacement necessary as the result of this work. teru atio Signatu of Applican or Agent Standard Pacific Homes - Rosie Lara 1717 E. Vista Chino Rd. Ste A-7 (949) 789-1600 (760) 218-8258 Name of Applicant (please print) Business Address Telephone No. To Be Determined Name of Contractor and Job Foreman Business Address Telephone No. 641665 Contractor's License No. City Business License No. Old Republic Insurance Company MWZY56825 Applicant's Insurance Company Policy Number FEES: Subdivision Improvement Permit - Class III Minor Improvement Permit - Class IV Inspection Fee Permit Fee As -Built Deposit Cash Deposit -Surety Bond, if required TOTAL $8,860.00 $100.00 $ 2,000.00 $10,960.00 Public improvements: 3% of estimated construction costs Private improvements: 3% of estimated construction costs See attached schedule PERMIT NO.5105 DAT PP OVED: EXPI 10 ATE: - p BY: _. Administrative Authority i' i Ji . b MR— Dimensionof • or - • t / Approximate Construction Start Date: !r//Zho(o Approximate Construction Completion Date: � Qro,,;9z e- Estimated Construction Cost: $ l 7 9, 601 +- 11 b.66 — A Z9' , Zt!, h . o 3 Estimated Construction Cost shall include the removal of all obstructions"materials, and debris, back -filling, compaction and placing permanent resurfacing and or replacing improvements Contact Name: Lc, Lin 6 Phone Number: _176oi 218 -k 2S Name of Applicant: Applicant Address: / ,e-- ✓ ` Applicant Telephone Number: /9`f ci) 7Sr9 Name of ContractorT 6 Contractor Address: T 3 Contractor Telephone Number: Contractor State License Number: CP 41/ Contractor City Business License Number: /0 12- 8"(0 ► A COPY OF THE CURRENT INSURANCE CERTIFICATE MUST BE PROVIDED t )l c nt or Contractor General Liability Insurance Company: A/p1p�licffant or Contraactor Gene al Liability Insurance Policy Number: l /I /Y !fin n—L I ` c � �n f i1L.- w i0 ( w 11A IA.," Office Use Only: Inspection Fee: p? o 6 0• O J Permit Fee: I Q 0, As -Built Deposit: 0 V Dust Control Deposit: Credit Amount: TOTAL FEE DUE: Office Use Only: Assigned Permit Number: Approval Date: ✓ J Expiration Date: Issue Date: Administrative Authority: " ` t �" '�' r OUTSTANDING BOND REPORT `Name: ---_____ Standard- acific Coachella Valley Tract No: 32279 77��. w D_ate_of-Contract: -February 8 2006 tea. Required Bond Amounts: ��� On -Site Grading $126,803 / $126,803 Storm Drainage $116,665 / $116,665 Streets $178,601 / $178,601 Water $101,833 / $101,833 Sewer $ 90,355 / $ 90,355 Dry Utilities $ 68,750 / $ 68,750 Perimeter Wall $ 64,32 0/ $ 64,320 Monumentation $ 1,000 Standard .10% Cont. $ 7.4,833 / $ 74,733 Prof. Fees Design $ 82;316 / $ 82,206 Prof. Fees Const. $ 82,316 / $ 82,206 Off -Site Storm Drainage $ 11,585 / $ 11,585 Streets $ 52,142 / $ 52,142 Sidewalk $ 7,590 / $ 7,590 Water $ 19,014 / $ 19,014 Sewer $ 4,460 / $ 4,460 Avenue 58 Street Light $ 4,000 / $ 4,000 Monumentation $ 2,000 Standard 10% Cont. $ 10,079./ $ 9,879 Prof. Fees Design $ 11,087 / $ 10,867 Prof. Fees Const. $ 11,087 / $ 10,867 Dates of Bond Reductions: (Note: Labor & Materials. Bonds are higher than required) Outstanding Bonds and Bond Company: Continental Insurance Amount: Bond No. Date Cancelled/Released: $987,792 (P1 929383642 5 $987,792 (L&M) same $133,044 1P1 929383643 ' $133,044 L&M same $ 15,000 (PM 10) 929388860 $ 5,000 (cash deposit in` Finance) ENGINEERS ESTIMATE - WATER & SEWER (CVWD) MIRAGE OF LA QUINTA�T,,WCTiN0N3227,9 JOB NO.: 175754 ENGINEER: P&D CONSULTANTS - 619-291-1475 DATE: 3-5-05 REV.11-1-05 ITEM QUANTITY UNIT I UNIT PRICE COST WATER: 8" DIP WATER MAIN w/ POLYETHYLENE ENCASEMENT 1,537 LF $27.00 $41,499 6" DIP WATER MAIN w/ POLYETHYLENE ENCASEMENT 8" D.I. TEE 20 LF EA EA $24.00 $200.00 $1,500.00 $480 1 1 5 $200 18"x18"x18" D.I. TEE $1,500 8" D.I. G.V. (EPDXY LINED AND COATED) EA EA $600.00 $4,700.00 $3,000 $14,100 18" D.I. B.F.V. (EPDXY LINED AND COATED) _ FIRE HYDRANT ASSEMBLY (WET BARREL) _3 5 30 1 EA EA $2,000.00 $1,000.00 $10,000 $30,000 1" SERVICE 8"x 4" REDUCER 8"x 6" REDUCER 4" B.O. ASSEMBLY 8" - 22 1/2 ° BEND 8" - 45° BEND EA $400.00 $400 1 EA $400.00 $1,500.00 $400 $3,000 2 1 EA EA $200.00 $200 $600 3 1 7 EA $200.00 END PLUG AND CAP EA EA $200.00 $20.00 $200 $140 2" PVC SLEEVE 12" STEEL SLEEVE ASSEMBLY 1 1 EA EA $2,000.00 $2,000 18" x 8" REDUCER $1,200.00 $1,200 TOTAL WATER: $108,919 SEWER: 8" V.C.P. SEWER 4" V.C.P. LATERAL 48" MANHOLE 1,509 LF $27.00 $40,743 30 EA EA $350.00 $1,500.00 $10,500 7 2 $10,500 6" CLEANOUT EA $250.00 $500 TOTAL SEWER: $62,243 Q�pFESSlnN SUBTOTAL: $171,162 �pYMO�yOgl<n 10%CONTINGENCY $17,116 c� 4� No. 44016 t" TOTAL: $188,278 Exp. MOM � ��qTE 8FAL �1-�FO��\p ��• Z PAUL R. KANE P.E. RCE 44016 DATE: PAENGR\175754-La Quinta.11\Excel\S&W-estimate-11-1-05.xls i II IMPROVEMENTS - ONSITE SHEET 2 OF 3 3" A.C. OVER 4.5" C.A.B. _($0.28 SF/IN AC; $0.11SF/IN CABS 62,075 SF $1.34 ___ $83,181 6" CURB & GUTTER 6" WEDGE CURB 491 LF $11.00 $5,401 2,433 LF $15.00 $36,495 6" MEDIAN CURB 1,163 LF $9.50 $11,049 STREET SIGN 1 EA $345.00 $345 4" SIDEWALK (P.C.C.) 1,765 SF $2.90 $5,119 MONUMENTATION - LUMP SUM 1 LS $1,000.00 $1,000 PERIMETER WALL DRY UTILITIES PEDESTRIAN RAMP 2,144 1,375 SF LF $30.00 $50.00 $64,320 $68,750 1 EA $750.00 $750 18" RCP STORM DRAIN PIPE 24" RCP STORM DRAIN PIPE WATER TIGHT JOINTS 151 LF $45.00 $6,795 562 20 LF EA $50.00 $28,100 $350.00 $7,000 STORM DRAIN CLEANOUT GRATED INLET STORM DRAIN OUTLET STRUCTURE 3 EA $4,000.00 $12,000 4 1 EA EA $3,500.00 $2,500.00 $14,000 $2,500 SAND FILTER & LEACH LINES 1 EA $5,000.00 $5,000 8" DIP WATER MAIN w/ POLYETHYLENE ENCASEMENT 1,619 LF $27.00 $43,713 6" DIP WATER MAIN w/ POLYETHYLENE ENCASEMENT 20 1 LF EA $24.00 $200.00 $480 8" D.I. TEE 8" D.I. G.V. (EPDXY LINED AND COATED) $200 5 EA $600.00 $3,000 FIRE HYDRANT ASSEMBLY (WET BARREL) 1" SERVICE 5 30 EA EA $2,000.00 $10,000 $1,000.00 $30,000 8"x 4" REDUCER 8"x 6" REDUCER 1 1 EA $400.00 $400 EA $400.00 $1,500.00 $400 $3,000 4" B.O. ASSEMBLY 2 EA 8" - 22-1/2 ° BEND 8" - 45° BEND END PLUG AND CAP 1 EA $200.00 $200 3 1 EA EA $200.00 $600 $200.00 $200 2" PVC SLEEVE 12" STEEL SLEEVE ASSEMBLY 7 1 EA $20.00 $140 EA $2,000.00 $2,000 8" V.C.P. SEWER PIPE 1,453 30 LF EA $27.00 $350.00 $39,231 4" V.C.P. LATERAL 48" MANHOLE $10,500 6 EA $1,500.00 $9,000 6" CLEANOUT 2 EA $250.00 $500 TOTAL IMPROVEMENTS-ONSITE: $505,368 P:\ENGR\175754-La Quinta II\Excel\ImpGrd-estimate-11-1-05.xls GRADING AND IMPROVEMENTS TOTALS: SHEET 3 OF 3 PAUL R. KANE P.E. RCE 44016 SUBTOTAL: $721,450 10% CONTINGENCY $72,145 TOTAL: $793.595 DATE: PAENGR\175754-La Quinta II\Excel\lmpGrd-estimate-11-1-05,xls ENGINEERS ESTIMATE - GRADING & IMPROVEMENTS SHEET 1 OF 3 MIRAGE OF LA QUINTA - TRACT NO. 32279 JOB NO.: 175754 ENGINEER: P&D CONSULTANTS - 619-291-1475 DATE: 3-5-05; REV.3-14-05; REV.11-1-05 ITEM I QUANTITY I UNIT I UNIT PRICE I COST GRADING I CLEARING AND GRUBBING 9.71 AC $575.00 $5,583 EARTHWORK (INCLUDES OVER -EXCAVATION) 54,610 CY $2.00 $109,220 FINE GRADING 30, LOT $400.00, $12,000 TOTAL GRADING: $126,803 IMPROVEMENTS - OFFSITE 3.'-'..A...C..OVER 4.5" C.A.B. ($0.28 SF/IN AC; $0.11 SF/IN CAB) 4" A.C. OVER 6" C.A.B. ($0.28 SF/IN AC; $0.11 SFIIN CAB) 1" A.C. OVERLAY .... ... ... .. .. ...... 8" CURB & GUTTER STREET LIGHT 6" A.C. DIKE 4" P.C.C. MEANDERING SIDEWALK (8- WIDE) 6" P.C.C. CROSS -GUTTER PEDESTRIAN RAMP MONUMENTATION - LUMP SUM 5% TRAFFIC CONTROL (<$1,000,000) STREET SIGN 18" RCP STORM DRAIN PIPE CURB INLET CURB OUTLET STORM DRAIN OUTLET STRUCTURE SAND FILTER & LEACH LINES 8" DIP WATER MAIN w/ POLYETHYLENE ENCASEMENT 18"x18"x18" D.I. TEE 18" D.I. B.F.V. (EPDXY LINED AND COATED) 18" x 8" REDUCER 8" V.C.P. SEWER 48" MANHOLE 1,342 7,006 10,814 S.F..- SF $1.34 $1,798 $1.78 $12,471 $4,866 SF $0.45 $11.00 359 LF $3,949 1 EA LF $4,000.00 $8.00 $4,000 201 $1,608_ 2,024 1,333 SF $2.90 $5,870 SF $5.15 $6,865 $1,500 EA $750.00 1 LS $2,000.00 $2,000 LS $2,246 1 EA $345.00 $345 43 LF EA $45.00 $4,000.00 $1,935 1 $8,000 EA $2,300.00 $2,300 1 EA $2,500.00 $5,000.00 $2,500 1 EA $5,000 82 LF $27.00 $1,500.00 $2,214 $1,500 1 EA 1 EA $4,700.00 $14,100 EA $1,200.00 $1,200_ 56 LF $27.00 $1,512 1 EA $1,500.00, $1,500 TOTAL IMPROVEMENTS-OFFSITE: $89,279 I P:\ENGR\175754-La Quinta llT=xcelklmpGrd-estimate-1 1-1-05.xls 9Ws A 01.1 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE STANDARD PLANS OF THE CITY OF U QXNTA AND THE STANDARD S-EORCA17ONS FOR PUBLIC WORKS CONSIRUCRO4 LATEST EDIRON, AND THE CITY OF LA QU/NTA STANDARD PLAN; DATE AUGUST 11 2001 OR LATEST EDIROV ON -SITE STORM DRAIN IMPKOVEMENT PLANS nrronr_z7 /)zT A InrrrnrTn ,ABERE N5: 2 IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER/OWNER OR CONTRACTOR TO APPLY TO ME CITY OF LAORTH OUINTA PUBLIC NARKS DEPARMENI FOR THE NECESSARY PERMITS AND 70 BE RESPONSIBLE FOR SATISFACTORY N NORM TRA CT No. 32279 COMPLIANCE WIN ALL CURRENT ENVIRONMENTAL REGULATIONS WRING THE LUFE OF CONSIRUCDOR ACTIVITIES FOR THIS F'RO.EGL ADDInORAL STUDIES ANO/OR PERMITS MAY BE REWIRED. E W �� *EST d LA Q UINTA, STATE OF CALIFORNIA J IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER OR CONTRACTOR TO APPLY TO THE CALIFORNIA AC ASPHALT commiE DEPARTMENT OF TRANSPORTATION (C4L7RANS) FOR AN ENCROACHMENT PERMIT FOR ALL WORK PERFORMED WITHIN C&C CURB AND GUTTER THE STATE RIGHT OF WAY. ESMT. EASEMENT 4. THE CONTRACTOR SHALL OBTAIN ALL PERMITS AS RECUIRED BY THE CITY OF LA OWNTA OR OTHER GOVERNING ° oN DEPTH m1R£cn°v AGENCIES & THE CONTRACTOR SHALL NOTIFY ME CITY PUBLIC WORKS DEPARTMENT 48 HOURS PRIOR TO ANY CRAVING. EA EX EACH DOSING _._ =: --"�-..:;'.- =`=r =_' G=::.d•",- j"c'i'�-. ». ;t}- ._...- ._. __.f ......, ��-: `ii BRUSHING OR CLEARING AND EACH PHASE OF CONSTRUCTION AT (760) 777-7075 AND 48 HOURS PRIOR TO WV. INVERT REWIRING INSPECTIORS LAT LATERAL 6. THE LOCATIONS OF EXISTING UNDERGROUND URU17ES ARE SHOWN IN AN APPROXIMATE WAY ONLY. THE IF MAX LINEAR FEET MAXIMUM CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL M17NC UTILITIES BEFORE COMMENCING WORK HE AGREES l0 BE DILLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY HIS FAILURE TO NO NUMBER EXACTLY LOG TE AND PRESERVE ANY AND ALL URUTIES NIS NOT TO SCALE PROP PD 7 THE CONTRACTOR SHALL BE RESPONSIBLE FOR TIME REMOVAL REPLACEMENT OR RELOCATION OF ALL PU£ PUSUC BLIC UTILITY EASEMENT REGULATORY, WARNING AND WIDE 9ORS RW RIGHT-OF-WAY a STREET NAME SILKS AND TRAFFIC CONTROL SIGNS TYPE AND LOCATION 91AU BE APPROVED BY THE CITY SW SIDEWALK ENGINEER. TRAFFIC STRIPING. LEGENDS AND PAVEMENT MARKERS TYPE AND LOCATION 91ALL BE APPROVED BY TYP TYPTCAL THE CITY ENGINEER PE PAD ELEVATIONS TV TOP OF RB 9. THE CONTRACTOR SHALL NOT DISTURB EOSTING SURVEY MONUMENTS OR BENCH MARKS NOTED ON THE PLANS fLC F ROW UNE OF GUTTER O OR FOUND DURING CONSTRUCTION REMOVAL AND REPLACEMENT SHALL- BE DONE BY A REGISTERED CIVIL PCC POINT OF COMPOUND CURVE ENGINEER WIN AN ACE NUMBER BELOW 3.1966. OR A LICENSED LAND SURVEYOR ONLY. PRC PONT OF REVERSE CURVE 10. CCNSM UCROR OPERATIONS AND MAINTENANCE OF EQUIPMENT WITHIN ORE HALF MILE OF HUMAN OCCUPANCY FC FINISH GROUND 94AU BE PERFORMED ONLY WRING THE TIME PERIODS AS FOLLOWS FS FEWS H SURFACE POINT OF CURB RETURN OC70BER IST TO APRIL 30TM. MONDAY - FRIDAY 7.00 AM TO 1-30 PM s BC c WRVS S4TURDAY &DO AM TO S00 PM £C END END CURVE MAY 1ST TO SEPTEMBER 307H: MWDAY - FIDAY &OO AM TO 7:00 PM RT, IT RIGHT. LEFT S47URDAY &00 AM TO 100 PM FL ROW LINE PE PROPERTY LONE WORK 9ULL BE PRLW37ED ANY 77ME ON SUNDAYS OR ON FEDERAL HOLIDAYS THE CITY RESERVES THE RIGHT TO ¢ LENTElI1NE APPLY FURTHER TIME RESIRTCTWS AS NEEDED TO WORK OCCURRING W ARTERIAL AND COLLECTOR SIM Is FN FIRE HYDRANT ASSEMBLY WRING H194 MAMC VOLUME HOURS ST LT STREET LIGHT & PULL BOX IT. ALL TRAVELED WAYS MUST BE CLEANED DORY OF ALL DIRT, MUD AND DEBRIS DVWTED OR THEM AS A RESULT OF THE GRADING OPERATION. GLEANING IS TO BE DONE TO THE SATSFACT°N OF THE CITY ENGINEER. O MAP rGr�,.ND I2 ALL CONSTRUCTION AREAS 91AU BE PROPERLY POSTED AND LIGHTED IN CONFORMANCE MTN THE STATE IMPROVEMEN7S SrMea MANUAL OF WARNING SIGNS LIGHTS AND DEVICES FOR USE IN THE PERFORMANCE Or WORK UPON HIGHWAY$ N ORDER TO CLIMINATE ANY HAZARDS 9HEEl NO OIL IJ CONSTRUCTION PROECIS DISTURBING MORE THAN ONE ACRE MUST OBTAIN A NATIONAL POLLUTANT D HARLE SHEET AREA - - - a1MN477ON SYSTEM (NPDES) PERMIT. ONNERS/DEVELORERS ARE REWIRED TO FILE A NOTICE OF INTENT (NO) SUBDIVISION BOUNDARY- MTN THE WATER RESOURCES CONTROL BOARD (SWRCB� PREPARE A STORM WATER POLLUTION PREVEN°CW PLAN LOT Na ! (SWPPP) AND MONITORING PUN FOR THE STE THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SM704 IS A NATKNAL PROGRAM 70 CONTROL NON -POINT SOURCE POLLUTANTS CARRIED BY STORM WATER. THE PROGRAM IS IMP(JEMENIED AND ENFORCED BY THE STATE WATER RESOURCES CONTROL BOARD. 14. THE CITY RETAINS TILE RIGHT TO REQUIRE PUN REti+9LNs AS NECESSARY, SU9SEOUENT TO PLAN APPROVAL OEM BUT PRIOR TO COMPLETION O' THE IMPROVEMENIS SHOWN OR THESE PLANS F ANY NEW SlTT , IMPROVEMENTS NAME AUC HOUSING PARTNERS INC HAVE BEEN INSTALLED BY THE CITY OR A TURD PARTY CUMIN THE IMMEDIATE VICINITY OF THE IMPROVEMENTS ADDRESS : 14107 WNaHESTER BLVD. SUITE N PROPOSED BY THESE PLANS THAT IMPACT THE DESIGN INTEGRITY OF THE IMPROVEMENT PROPOSED IN THESE LDS CA= CA 95032 FUNS AS ORIGINALLY APPROVED. ALL COSTS INCLUDING BUT NOT LIMITED TO DESIGN AND IMPROVEMENT o0SM In (408) 866-5511 FAX (408) 866-55M INCURRED AS A RESULT OF ANY DESIGN REVISIONS SHALL BE BONE BY THE NPROVOWENT SPONSORS iS THESE PLANS ARE VAUD FOR A PERIOD NOT TO EXCEED ECRTEN (18) MOUTHS FROM DATE OF APPROVAL ASSESSORS PARCEL N0: TIE IMPROVEMENT SPONSOR SHALL BEAR ALL COSTS ASSOCA TED MTN UPDATING THE FUNS INCLUDING BUT NOT 762-240-11 LIMITED TO DESM AND IMPROVEMENT COSTS To AFFECT aMPUANGE WTH ANY NEW Cry STANDARDS ORDINANCES OR LAWS AND REGULATIONS ENACTED OR ADOPTED BY THE CITY OR OTHER VRMCIAONS WITH AUTHORITY SUBSEQUENT TO THE PLAN APPROVAL DATE CONTRACTOR NOTES: SHEET INDEX MAP. 1. ALL LOCAL DEPRESSIONS SHALL BE CONSTRUCTED PER STREET IMPROVEMENT PUNS IN ACCORDANCE WIN Cry OF U WNTA STANDARD PUNS HOWEVER, ALL CATCH BASINS WILL BE CONSTRUCTED PER ME STOW DRAIN PLANS EXCEPT FOR ME AVENUE 58 INLET W 04 WLL BE CONSTRUCTED PER TH£ STREET WPROVEMENT PUNS 2 ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS AND THOSE SHOWN ON THE RECORDS ARE OCC71D WIN THEN APPROXIMATE LOCATION AND EXTENT. THE OWNER. BY ACCEPTING THESE PUNS OR PRECEDING WITH THE IMPROVEMENTS PURSUANT 7 EREM AGREES TO ASSUME LIABILITY AND TO HOLD UNDERSIGNED HARMLESS FOR ANY DAMAGES REPORTED TO THE UNDERSIGNID, NOT INDICATED OR SHOWN ON THE RECORDS EXAMINED. THE CONTRACTOR IS REQUIRED TAKE WE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR STRUCTURES SHOWN AND ANY OTHER AMF49MS TO PR07ECT THE UIILIRES OR STRUCTURES SHOWN AND ANY OTHER U7TURES OR STRUCTURES FOUND AT THE SITE IT SHALL BE CONTRACTORS RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES CONCERNED BEFORE STARTING WORK. A CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WIN GENERALLY ACCEPTED CWSMUC77CIV PRACRCES CONSTRUCTION CONTRACTOR WILL BE REWIRED TO ASSUME SOLE AND COMPLETE RESPON-SIBILITY FOR JOB SITE CONDITIONS WRING THE COURSE OR CONSTRUCTION OF THE PROECr INCLUDING SAFETY OF ALL PERSONS AND SiEFF AID 777LE J COVER SHEET 2 FYPArAL DETAILS 3 UN£ A: LINE 9; LINE D• LINE E• AND UNE F• 4 LINE 9• AND LINE 'C• PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE 70 APPLY CONTINUOUSLY AND NOT BE NOTED 70 NORMAL m, M79 I37DIIU WWMC HOURS AND CONSTRUCTOR CONTRACTOR FURTHER AGREES 70 DEFEND, INDEMNITY AND HOLD DESIGN Bl9N NOT SIZED FOi PROFESSIONAL HARMLESS FROM ANY AND ALL UARUTY, REAL OR ALLEGED. IN CONNECTION WITH THE PERFORMANCE 0791E MANAGE FAO OF WORK ON THIS PRO.ECT, EXCEPTING UABUTY ARISING FROM ME SOLE NEGLIGENCE OF DESIGN PROFESSIONAL IR .T[HY4 I. P&D CONSULTING MAKES NO REPR£SENTAROV CONCERNING THE ESTIMATED QUANTITIES ON ' THESE PLAN$ OMER MAN THAT ALL SUCH FIGURES INCLUDING ALL EARTHNERK NUMBER; ARE PRELIMINARY ESTIMATES AND FOR PERMIT PURPOSES ONLY. IT 9OLL BE THE I CONTRACTORS RESPONSIBILITY TO PREPARE HIS OWN QUANTITY ESlIM47F FOR CONSIRUCRON _ AND OR COST PURPOSES ME ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY DEVIATIONS BETWEEN ESTIMATED QUANRRES AND THE ACTUAL QUANTITIES AT THE TIME ON S (FL000 ZONE DESIGNATION "X" pANEI 0709001OB DATED 08-19-91 i �-,1./I� I I�i VICINITY MAP \,lr 1 I - /,• . I I N7S P ( - it `. ti Jb5 }. . O - °"i ,/ CBB2 =a.a as i I •' ` -8.6 .CF'S - 4.p&7 CFS "' 0 . 1` =aCFS ( °' 100• 0' 100' 200' J00' i.q_ `•i•� T',N �� i %� '^. �` � ^. TI � f `�^�� GRAPHIC SCALE: 1*=100' '.°aka- r. �... � ,. .. •.� J-�`�..�1'-�--� ... CE Li I Y• 1� II i, - ,� ` �T �i- ;-TFMEREfNCX 01fRE1vN7/ _ SCALE.- 11-100' RMA77ON WA TER COACHEILA VALLEY WATER DISTRICT .......... (760) J98-2651 SEWER C A00 A VALLEY WATER DISTRICT , , , , , , , , , , (760) J98-2651 ELECTRIC IMPERIAL IRRIGATION DISTRICT ............... (800) J03-7756 GAS • THE GAS COMPANY.............................(800) 427-2200 TELEPHONE WRIZZON................................(800) 48.E-5000 CABLE TV RUE WARNER CABLE .......................(760) J40-IJ12 USA: UNDERGRQUND SERVICE ALERT ................. (760) 227-26W CONSTRUCTION NOTES AND QUANTITY ESTIMATES NOTE: USE TOPE V PORTEND CEMENT PLUS POZZOLAN WIN A MAXIMUM WATER CEMENT RATIO OF O45 USING A MINIMUM 4,500 PSI CONGRE7E MIX ON ALL CONCRETE STRUCTURES IN CONTACT WIN SOT. STORM DRAW NOTES: 1. ALL CONCRETE IN REINFORCED CONCRETE SIRUC711RES MUST BE 3250 POUNDS PER SOUARE INaI IN 28 DAM' TYPE OF PORTEND CEMENT CONCRETE TO BE DETERMINED BY COUNTY OF RIVERSIDE MATERIALS LAB. 2 ALL PIPE LENGTHS ARE HORIZONTAL PROECnONS UNLESS OTHERWISE SHOWN. J FOR TRENCH EXCAVATIONS IN NATIVE SOIL SHORING SHALL BE PROVIDED AS REWIRED TO SA RSFY STATE OF CALIFORNIA SAFETY REOUIREM00S. 4. PPE CONSTRUCTION IN FILL AREA MUST BE COORDINATED WITH THE GRADING TO ENSURE THAT WHEN THE FILL OPERATION HAS BEEN COMPLETED WIN THE GRADING TO ENSURE THAT WHEN THE FILL OPERATION HAS BEEN COMPLETED AT GRAD& THERE IS A MINIMUM 1 FEET OF FILL ABOVE THE TOP OF PIPE. S ALL WORK MUST BE IN ACCORDANCE WIN ME STANDARD PLANS OF THE CITY OF LA QUINTA AND THE STANDARD SPEanai nOR5 am PUBLIC WORKS CONSTRUCTION, LATEST EDITION` AND RIVERSIDE COUNTY STANDARDS AND SPECF1C417ONS ORDINANCE N0. 461. LATEST EDITION a THE CONTRACTOR MUST NOTIFY THE CITY OF U WINTA INSPECTOR AT LEAST TWO (2) WORKING DAYS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION. 7. ALL FILLS MUST BE COMPACTED 70 90% RELATIVE COMPACTION AS DETERMINED BY THE CAUTORNIA TEST METHOD NO 21a 1978 FIVE LAYER METHOD" ALL BACK FILL MUST BE FREE OF VEGETATION MATTER B. ALL SURVEYING REWIRED FOR VERTICAL AND HORIZONTAL AUORMENT MUST BE PROVIDED BY ME CONTRACTOR OF DEMOPER AND SUFFICIENT REFERENCE STAKING BUST BE IN ACCORDANCE WIN THE REQUIREMENTS OF THE CITY OF LA WINTA INSPECTOR 9. ALL REINFORCED CORatETE PIPE MUST BE BEDDED IN ACCORDANCE MTN PIPE BEDDING DErATL PER COUNTY OF RIMYSEE STANDARD PUN 81a is PRIOR 70 THE COMMENCEMENT OF CONSTRUCIM THE DEVELOPERS CONTRACTOR SHALL OBTAIN A PERMIT FORM ME STA IF ONSION OF INDUSTRIAL SAFETY. A COPY OF PERMIT SHALL BE KEPT OR THE XB 9TE AT ALL TIMES 11. PRIOR TO THE PLACEMENT OF STORM CRAIN IMPROVEMENTS THE OEVELOPERS SIKS ENGINEER SHALL CERTIFY IN WBTNG 70 THE Cry CE LA WINTA INSPECTOR THAT THE STORM DRAWY SIB GRADE IS OF ADEQUATE STRENGTH TO SUPPORT ME STRUCTURES AND ANY ANTIaPA70 LOADS 12. ALL SIM THAT IS M BE CON7IN000S 0 AND LESS 94AU BE LAPPED A MINIMUM OF 45 BAR DIAMETERS FOR BARS /9 AND LARGER THE MIN LAP IS 60 BAR DIAMETERS 11 ALL MATERIALS TESTING FOR THE DRAINAGE FACILITIES SHALL BE PROVIDED BY A MATERIALS LAB IN ACCORDANCE WM THE NUMBER LOCATION, AND FREQUENCY REQUESTED BY THE CITY OF LA WINTA INSPECTOR. It CHAMFER ALL DP0.® EDGES OF CONCRETE 3/4- MIN. IS LENGTH OF MANHOLE STRUCTURES MAY BE INCREASED TO MEET PIPE ENDS A T OP71ON Or CONTRACTOR AS LONG AS REINFORCING SIM IS CONTINUED AS REWIRED. ANY CHANGE IN SPUR LOCATION MUST BE APPROVED BY ME ENGINEER I& ROOK OF MANHOLE STRUCTURE 91AU BE STEEL IRONUM TO SPRING LINE 17. BUOY OF MANHOLE STRUCTURE NOLUONG SPUR MUST BE POURED ON ONE IXW77NUOUS OPERATION, EXCEPT THAT CONSTRUCTION JOINT AT THE SPRING LINE WIN A LONGITUDINAL KEY WAY IS PERMITTED. Ia ALL REINFORCING BARS MUST BE SECURELY HELD IN PUCE IN TIRE FORMS TWO WAY MATS OF SIM MUST BE WIRED TOGETHER BOTH WAYS AT ALTERNATE IN70MC170NI 11 STORM DRAW BAG( FILL FOR ALL FACILITIES WnffN STREET RIGYHT-OF-WAY b TO BE PLACED AND COMPACTED UNDER CITY INSPECTION AND MEET OR EXCEED CITY OF LA OWNTAS MINIMUM STANDARDS 2a ALL PIPE TO BE BANDED AND GROUTED (Q4• OUTSIDE ONLY, >24FNSIDE AND OU7SDE)L 21. RCP SHALL COMPLY WIN ALL AS774 APPLICABLE STANDARDS 22 ALL LOCAL DEPRESSIONS SMALL BE CONSTRUCTED PER STREET IMPROVEMENT PLANS IN ACCORDANCE MTN CITY OF U WNTA STANDARD PUNS HOWEVER ALL CATCH BASINS WILL BE CONSTRUCTED PER THE STDRM DRAW PLANS AND WILL ALSO BE SHOWN ON THE STREET WPROVEMENT PUNS 21 ME CONTRACTOR SHALL CONDUCT CONSTRUCTION OPERATIONS IN SUCH A MANNER THAT STORM OR OTHER WATERS MAY PROCEED UNOITERRIUPIED ALONG THEIR DOSTING STREET OR DRAINAGE COURSES 24. IN THE COURSE OF WATER QUALITY CONTROL THE CONTRACTOR SHALL CONDUCT CONSTRUCTION OPERATIONS W PROTECT WATERS FORM POLLUTION WIN FUELS OILS 817UMENS OR HARMFUL MATERIALS 11 LOCAL DEPRESSIONS AND DECKS OF CURB INLETS SHALL NOT BE POURED UNR ADJACENT CURB AND GUTTER HAS BEEN POURED. PROJECT NOTE: 1 THE INTERN RETENTION RASIN WTHIN ADJACENT TRACT N0. 113.T6 AND RELATED STORM DRAW / SAND FILTER FACU17ES SHALL BE CONSTRUCTED WIN TRACT Na 32279 IMPROVEMENTS AS SHOWN ON SHEET 3 ITEM / DESCRIPTION UNIT QUAN71 r CONSTRRCl SO MANHOLE PER RIV. CO STD. ONG. NO MN251 EA J O CONSTRUCT CEM INLET CATCH BASIN PER CITY OF U OVINTA SRO DING N. MO W & H PER PLAN EA a COST. WRIER DEPRESSION FOR CURB OPENING CATCH BASIN PER CITY OF LA OUNTA SOT. OM N. 3.T0 CASE C (SAGI EA 5 O COSST GUTTER DEPRESSION FOR CURB OPENING CATCH BASH PER CIFY OF LA °UINTA STD. DWG No. JJO CASE B GRADE EA 3 P CONSTRUCT OUTLET STRUCTURE PER DETNL SHEET 2 EA 3 O CONSTRUCT SAND FILTER AND LEACH LINE PER CITY OF LA DING No DNO 370 MER GPPLAN J A 0WEA ENCASEMENT PER RGF.0 M807 EA 2 a CONS7RUCT POLTEMYLENE ENCASEMENT EA 1 P COSST. 18 RCP D LOAD PER PLAN & PER CAL TRANS A62D LF. 230 N COAT. 24" RIPD LOAD PER PLAN & PER CAL TRANS A62D LF. 705 CITY of LA OUINTA Plan Set No. 052J0$ LEGEND: ILg SIM6QL PROPOSED SLOPE (2I MAX) ........................ - T__ : J PROECT BOUNDARY ................................. - - LOTLINE .......................................... TIGHT -OF -WAY AND FLOW LINE ...................... 6 A.C. DIKE ...................................... . PROPOSED CONTOUR ................................. 550 EXISTING CONTOUR ................................. PROPOSED SPOT ELEVA RON.......................... >rX� PEDESTRIAN RAMP ................ ....... _.... ADL STORM DRAIN CURB INLET STORM DRAIN MANHOLE 100 YR. FLOOD LIMIT..... DAYLIGHT LINE , , , , , , .... UNDOGROUND UMJ71ES ALL UNDERGROUND u77u7rts OR STRUCTURES R7>,aRTm BY THE OWNER OR OTHERS AND THOSE SHOWN ON THE RECORDS EXAMINED ARE INDICATED WITH BASIS OF BEARING 75 OR FOR OLDS MAP A WE Vr- PREPARED UNDER THE ORECnav OF• PAD CONSUL RANTS, INC. 6951 R70 SAN D/fC7 QRNVE SUNIE 6J0 IN RE CITY OF LA WNTA STATE OF CALIFORNIA ON -SITE STORM DRAIN - THEIR APPROXIMATE LOCATION AND EXTENT. THE OWNER, BY ACCEPTING THESE PLANS OR PROCEEDING WTH IMPROVEMENTS PURSUANT THERETO AGREES TO ANMERNNGS RANGE 7 E, 5AN s�AwDN°'MER'°IA" 'S 5T'°W RA E SOLMMY LINE OF SECTION 21, TOWN9IP 6 SOUTL R. p'ro R. Fy�Y Q� y A_____ 11 11.OS SAN DVE02 CAUFORNIA 921D6 IEEE' (619) 291-1IL75 FAX- (619) 191-1176 IMPROVEMENT PLANS TRACT N0. 32279 PAIL R. KAN ECP. DATE' 6/J0/07 ASSUME LIABILITY AND TO HOE) UNOFR9CRID HARMLESS FOR ANY DAMAGES 4E OR MACE NO 280.H, Ma25Hj/0. R89'4075" E y A R.CZ 44016 _ -, RESULTING FROM EM7ENCE OF UNDERGROUND UTILITIES OR STRUCTURES NOT REPORTED ro THE UNDERSIGNED!, NOT INDICATED OR SHOWN OR ME RECORDS EXAMINED. THE CONTRACTOR A REWIRED TO TAKE DUE PRECAUTIONARY Underground Service Alert Call:TOLL FREE N. 44M EIm- 6/30 6 ? APPROVED BY^ C7Y OF U OULNFA '� �MIRAGE SCALE SEE ABOVE CUT BOX LW SOU1HE.lST NENC WALL OF COAL BRDL� 2 MILES SOUTH ALONG JACKSLW STREET FROM HIGHWAY 111. OF LA QU I NTA QF�91R MEASURES TO PROTECT THE UlUl1E5 OR STRUCTURES SHOWN AND ANY OTHER - MARK REVISIONS APPR. DATE y CIVV H! y9 CIS / MEN 2 MILES NEST ALONG AVE 50. 45 FEET NEST OF U7RITES OR STRUCTURES FOUND Al THE SITE IT SHALL BE CONTRACTORS 1 -800-'227-2600 (#- \ DA7E.• MADISOV 51/ZEET, 18 iFET SCUM OF CfHTERL1Nf AVE 5D f 7 RESPONSIBILITY TO NOTIFY THE OWNERS Or THE UTILITIES OR STRUCTURES CONCERNED BEFORE STARTING WORK. 7w0 MRKDX DAYS BEFORE You Dp DESIGNED BY: DRAWN BY: - CHECKED BY: DMO R. OA; P.E R.GE. PUBIC NURNS' DIRECTOR/ EYP. DATE.- 12137 6 C17Y &1WNEJSR 27.941 (MEAN SETA LEVEL DATUM) PER pry OF LA OUIMA VERTICAL CONTROL DATA - FOR D.U.C. HOUSING PARTNERS, INC. P:\ENGR\175754-Lo Ouinto II\IMP\UnU11ES\STORM DRAIN\175754SD01.dwg 10/13/2005 9:10,.50 AM PST ' 1 - DATE: 07/29/2006 $ �Q a p'o r3 glR^ 'aiw �a�$ ozu@ f` i >g o b1 wSS� `�IoZWR $�-W x 8 ¢$W as WS a az �3tipZ 2U N W 1G aa`i ` $� p'_^ y $ a N W N_g 4"� as WUi zKp> bY$� 000yp� q c$ �o2y�ks a� w O?� 2�jA ONi o 20 P W W �a a N pWU 22 y 22 ya �uZe O O$ � �2�1l W 2W $ >?x >�� O p� 3U a 4� 6 W GOxc pZZ O d ��i�777{{V 02W %' ga N � < $� ¢ R � ag Na>' 6 aU Pis 2 g Sj,R� x - x� �m g t> a g $Na oQl'<n c�Q.,�o� W�P.l aaa4'x] S `In� �2mlI..�� $ "o bma2W'YhpmSaa W4_z 2 W�pateQ^aR�`$•' $Npo�vWCCf $eW6 2`iIgi$Y25 QFmgi av n 2 _I z e �'$ !W $o P aag<tzi ayydaq�i �Ka<��g°s<Woaz2 RwoQ$ �m�. m�N�$2aW�Uz<0mW>���3z `Sp$�a•I WoN33}a22x UNpg2RNa N$Ro$6�`2Q�•"°�oN_ �izo$,iW��G���a�u �yym,u„~z,�0.Gyya�ajSi �y3uc�'z' QNe �w$z-y2 �pWW�iZ�o-ZY�x N�ggCu< I=4WSZa�, UWo��e o�ozu b 8 = oe $� h �yao tl w$�W WzW IZYm EIg W 9 R o�`HLQI.,.� � i e WHsuis �•'� 1z�n be e2C�0 �R aCA �av aa5 2 m e pW o 0 2 �zm NN a bx ao �c 2 SoWpa 'V K b c`Y� aN x x S'd' bi "' a Pp W'p-:i Ra��i�u $'d �_ �ZQ�m w $ 0 pp 8 > S q$ 'd S�Y^a'SN2 Xol^og�Cu�a��Cx¢b 1G�N2���Kg$< �N O K $ �p I� Rei W CN t50� W Q y O :5 6 N U a �u <� I� $ Z > W ��UU�� R¢ 2R� '� �- < O oU `iZia W_Oaj �¢� Uy2 Nc -¢Xp I�`+2U 2W 2O(� O'_p3 Zp $ pW�N O �1 $ O F Z c O 9 2_ U3 O aU Wx�Q�� m6�a gN�5 W 3$ z 3 $ m Sao ^�R zCx m oo�zyy s WN s N z K�3� � �pR� 1uuo� y$ �r NQ22>$ w g Qg x0 � a abI �U N �03 CG , 2 8LS O -92Ue H<t Oa g�X+KQ i- UR - ^s ? UJ 2 a $2p2 < x< zQ R2 ?QN o zw I 2 30 �+ g� UU Y� M-Up LWN�u zg z6u 4^ $ wRQ Wx ,y$> ci p a > 6N z,g uo LT IN ¢ && Q o`" 'b $c� Wp p a oa a $ b:'3$�5 fsl2�� a $$ S2N �aS 9y a�R 2Zx W<V7 d$ gR^4s &�9$z 13 h g$mm aaoupZ� �N S �` z U 2 m ,N"WO S O p 6 FN� Fg p W e' < 5�s 3R < ~ aOFig m a o� S,RY m� Z Z � $o o i �$ 2 8 �m ( bxxzh PIS >zl � o ` '� zoo Csl za R� F3 zo 2 $ o zd e �a] 2� " 'a & yoza os yiz o Si ' > > c�W o pW aF $ 20o N , +7,$W W o � b � Fo Er < OZ� 89 - � ca `�'a Q 'd'� aNW <�'a n �WA 2p �'is C�z " W6m `� �N_ �'i ` �k �� N,n� �� �'a S�'a wN G 2 g z�21 $Z 2NN 2cs �Wu 'rj z_ R� Z o$ lzE� >$Z�~ O $W op��41 aWca��x�[ a� km uW Oa mpo �i3 < &$ $ 0 4 $u ul a(,' S '60�,,'•` 3' a < o� ok�p`J' c�`d"N$o� $A W$ a 22 x Qc8 8 x < z N �.Ia' C x� 1� yGK Q 1i O k' 'qyG QyK R a U a G 3$ G=� 22xa- 2 !]7�b1 i�2¢1S F. aW `R :EZS UGN 2 �n 2a U UOU N 2� p4f 34 a� WW j�2 6� �O a UH N V�4. V �NI.% S ? O O$2_� Lt 1W Wm gWa Qa WRi <� G a I'/> mW g oil cSka za zQz o¢ zWy�$Nm � m p ��xg�$� H IIj �po W �o ^� o� �T ^ G� ''aao m < �p ¢LY Pz �o " h6 h1� �K'a� $ oo W 3 W PAL vz `8 ago = ` b � �,3<e �N((($ay$o( 2C>O ��b[j $$ �y gRapN .CNN N3 r•f0 �Q N�C .p (�¢W a c6W vi$2 C� O i QO .ii Lia$ A. '���$Q 'id ep� �L�WO�U v{A + W2+ a 1N3NWd JO 3003 a p n b V W 2 G e, � 2 �-N�]mou_— m� a W Ni Wa� a �t V pl z O <z V) � W Q n d y F-< Z U1.13 J �WaN V O w. 2 NNZ M Q N < W J U l` U 4- c INIW Z O N a OZOF•- OwU W W O m a a Q- z z — F- S � s 2Q 3N< Wdm' gjF�lY f/o7 � ZF�8 W ep I �� 2 N m BIE v � LZ�i Q 'V 2 G O O a U 2 S t u 8o1W��i�u2C�g$g8 ZaAd° b m _ � ti y e j N ... �— ..--....J----II LI LI II 1. AI — 1I -1-1 t ItU -((10I --u.1I .11. Ii I o S W ' UU S `j,f �%'nQ O�W "'- t� � L-, l� • Ai,;L.. R y - IILLyy ' < m 4i c; e c) ---- ------ ' � � � r I � i�c'`i' mcPd •�(�� Z�� U i I�` Ci il�'�tFER �F bi o- Nnmr� as a(a s>rl ¢o�'do udo Ow M888RL .DMAIS BBi.eDNml�LALtB �� A-37 Ill III ® R R R A ar Nam A u00 I P, a 4 _ p t. MW aoa�e I� ,u Nln �_ I uci7 ire II _ pi III 1- II?I II lilo oae 15 OI� - - — --- --- - — r W — —_ LN — — — ———————— — J,--r Y R- � cc GRR< R _—W ,u ___ b UK•om j Gim CAW Nj Q ^iR2 n e3 N o n W z W 2a Ne Z 1 Ain a Ul to o� g epp t1 /Wy � O o� H 4 j oc L W o� •a n I e a AoM uooi �_ '15 vos!poN o:c1 oWn ]n non Q � C = O L 'q 'Nry IOJo•J I < 2)21 w O Vl orn b W d ,JI `O W `W T 1 N Q t � a y] e \ w1SI038 * �! j �: W KJJJW I:wd W N dddW W W W J4i dd 4i d d W N 1��1W R Z $g_ t Aar 's a �aaz�aa$. aaka�3$$pu' call i� g a a i C 2 N �020�����W I}''��zaNNz�]N�ziN 22 z6N�zJ U b b b V R 2 R 01 � W K $ 0Cw „gyp ♦n 2 N e$J 7 i gg $o E b 11 >pdaz g. WO ipV y b$e^ 7 aZW N Hk �n Q'i 8 1='gN 2 i2 �•,�t� ��,�2 4�P. ti �� 2��5 �<a Lei t�� �p� N �I � U ��� z qz W 3S� e�t•' �t171 Q �� �ik$� �71(� ��� � ti Li ZRZ rOr_ �� i_. (� W$c7< N Z �oi R•' OZo O %•t � iF c mN Gm aa� F12 U Cy a $ rF o 2oi du�q�t �G o93$ e$o �aR� T-;KaSZ$��3 4tn$�uo1 g 9a3_i 8A Aa gbl 3 W V i w&(,] =g� W22 z d> a 11yyY� Sau�CzCeo�= ct b 8 z all b E- N _ N ' k> W wd tia iiW z z� o �9 uw z¢$k k z SW z a `i E~ �"i E~-I3W� W ° ►�. big < `$ a -f a �zibmW 8 n Oa E Cii ��8 3uW Wka R R a, akOW�` tiyh H� :do?n K2�< eo n V H W R$� p� Lt �y1�C=q 2�g�3p `cYNS2- z 4Wu 2 � 266 N U zOz V i-Q�UttU��It>�K�z �`2Qyyyy.a�N�oY���Q a U �.�.Q 2NWaW xW L U I.fO�pQW� k o �ii�coi�`o`IexseZa�z wG 422�Us t. Ula4�<Ot�i �NN$ii x �pZ''WWNON JxW yp2 iQrG W Vim - S W1'�+=W��2aS Vp p b{L••W WWUO Op - City of La Quinta The following General and Special Provisions are attached to and made a part of Permit Number 05105 The following shall always apply: ENCROACHMENT ON PRIVATE PROPERTY: This permit authorizes work to be accomplished within the City of La Quinta's right of way ONLY. Whenever construction extends within private property, it is the responsibility of the permittee for his contractors to secure permission from abutting property owners. Such authorization must be secured by the permittee prior to starting work. TRACK -LAYING CONSTRUCTION EQUIPMENT: Cleated track -laying construction equipment shall not be permitted to operate on any paved surface unless fitted with smoother -faced street pads. All mechanical outriggers shall be fitted with rubber street shoes to protect the paving during excavations. Rubber -tired equipment only shall be used in backfill operation in paved areas. If the existing pavement is scarred, spalled, or broken during the term of this contract or if the pavement is marred, City of La Quinta shall request that these portions of road be resurfaced over their entire width. Resurfacing shall consist of one coat of two inches (2") of A.C. surfacing plus appropriate seal coat as specified above. PROTECTION OF TRAFFIC: All excavations and work areas shall be properly lighted and barricaded as deemed necessary by the City Engineer or City of La Quinta Public Works Inspectors. Suitable detours and detour signs shall be placed and maintained for the duration of the project. The City shall be notified twenty-four hours (24) in advance of any traffic detours or delineation. CARE OF DRAINAGE STRUCTURES: Any drainage structure to include corrugated metal pipe, concrete pipe, steel culvert and concrete structures encountered during excavation which necessitate removal shall be replaced in kind. In the event it becomes necessary to remove or cut existing drainage structures, City of La Quinta shall be notified prior to commencement of this work. Drainage structures and open drains shall be kept free of debris at all times for proper drainage. RIGHT-OF-WAY CLEANUP: Any surplus material resulting from excavation and backfill operations shall be removed from the right of way. All paved surfaces shall be broomed clean of earth and other objectionable materials immediately after backfill and compaction. Existing gutter line and drainage ditches shall be replaced to their original standard or better. All excess material shall be removed prior to paving. Water tanker shall be used, as required, to sprinkle the job site to keep down dust conditions and shall be used immediately after backfill. DE -WATER OPERTATIONS: If de -watering operations are required and pumps are forcing water on City of La Quinta roads, it shall be the responsibility of the permittee (contractor) to control this water and to provide off-street barricades when necessary. CLOSING STREETS: No street shall be closed. A minimum of one lane of traffic shall be maintained at all times to provide limited access for the adjoining property owners and emergency vehicles. In the event it is felt by the permittee that he must close a street for any length of time, permittee shall contact this office to obtain the necessary permission. SPECIAL PROVISIONS The following shall apply when indicated: ® R1 NOTIFICATION: Permittee shall be notified the City at (760) 777 - 7097 at least forty-eight hours (48) in advance of starting construction. ® R2 UTILITY CLEARANCE: (Substructures) Prior to making any excavations within the City of La Quinta right-of-way authorized by permit, the permittee shall contact all concerned utility companies relative to the location of existing substructures. Damage to existing substructures resulting from operations conducted under this permit shall be the sole responsibility of the permittee. ® R3 UTILITY CLEARANCE (Surface Structures) No work shall be done under this permit until all utilities are clear of the proposed work site. The permittee shall notify all concerned utility companies of the proposed work. ❑ R4 PAVEMENT WIDENING: Area between the proposed concrete gutter line and the existing road pavement shall be surfaced with (•• N/A "') inches of A.C. paving placed on ( " N/A ") inches of ( " N/A ") aggregate sub -base course having an "R" value of not less than ( ** N/A "") and in conformance with the City of La Quinta Road Improvement Standards and Specifications, Ordinance #461. ® R5 PARKWAY GRADING: Area between the property line and top of the proposed concrete curb shall be graded to a slope of one-fourth inch (%") to one foot (1'). ❑ R6 GRADE CHECKING: City of La Quinta shall check grades upon receipt of plan and profile and/or grades as established by a licensed engineer. ❑ R7 CURB REMOVAL FOR DRIVEWAYS: A portion of the existing concrete curb and/or curb and gutter ( '* N/A ** ) feet shall be removed. Curb and/or curb and gutter shall be saw cut prior to removal. Depressed curb, matching concrete gutter and concrete driveway approach shall be constructed in conformance with City of La Quinta Standard #207. ❑ R8 DRIVEWAYS: A.C. driveways shall be constructed as not to alter existing drainage pattern. Surfacing between the property - Fine and the existing road paving shall be two and a half inches (2 %") of A.C. paving on ('* N/A ") of class (" N/A " ) aggregate base. ® R9 SIGHT CLEARANCE: Sight Clearance of six -hundred feet (600') in all directions shall be assured and maintained at all times. ❑ R10 SOIL STERILIZER: The area to be surfaced shall be treated with soil stredlizer. Rate of application shall comply with the manufacturer's specifications. ON of La Quinta ® R11 COORDINATE WORK: The proposed work shall be subordinated to any operation, which the State of California or City of La Quinta may conduct in this area during the period of this permit. Work shall be coordinated with the State .or City of La Quinta forces to preclude delay or interference with State or City of La Quinta projects. ® R12 SURVEY MONUMENTS: Prior to excavation or beginning of construction, all survey monuments which exist on the centerline of all streets or property lines when included shall be completely tied out so they may be readily and correctly, replaced by a licensed civil engineer or surveyor at the expense of the permittee. A complete set of notes showing the ties to these monuments shall be furnished to the City Engineer prior to the removal of any monuments. This office shall be notified upon completion or replacement of all survey monuments for proper clearance. ® R13 PAVEMENT CUTTING: Pavement will be mechanically saw cut to a straight edge prior to excavation. Method of pavement cutting shall be approved through the office of the City Engineer. (Under no circumstances shall excavating equipment be used to excavate prior to cutting or pavement.) Excavation material shall be placed in such a position as to best facilitate the general flow traffic. Prior to final paving operations, any damage to pavement straight edges shall be corrected. ❑ R14 LIMIT OF EXCAVATIONS: Excavations shall be limited to one -thousand feet (1000') of open trench before backfill operations must begin. All excavations shall be properly barricaded with lights overnight, on weekends and holidays for the protection of the traveling public. The Public Works Inspector shall determine the suitability of excavation barricading in each case. No excavation shall remain open for a period exceeding five (5) days. No excavation shall be made unless the construction material is actually on the work site. ® R15 BACKFILL MATERIAL: Backfill shall be free of brush, roots or other organic substance detrimental to its use for purposes of producing and adequately consolidated backfill. Ant material which the Cityof La Quinta deems unsuitable (spongy or saturated material) which is encountered during excavation shall not be used for backfill, but shall be supplemented or replaced by an approved sand or gravel. ❑ R16 BACKFILL SAND: Backfill shall be approved transit -mix sand or equivalent and shall be placed on lifts not greater than three feet (3') and vibrated using vibrostamper or equivalent equipment. Alternate methods may be substituted, but in any case, a relative compaction of ninety-five percent (95%) shall be maintained with the structural section of the roadway. ❑ R17 BACKFILL PLACEMENT: Backfill shall be applied in layers of not more than fifty percent (50%) of the total depth of the trench before flooding or a maximum of five feet (6) lifts where trenches are of excessive depths. Care is to be exercised that the backfill material is not subjected to extreme swell by flooding operations. Backfill material shall be placed so that the resulting compaction shall not be less than ninety percent (90%) or equivalent to the surrounding ground, whichever is the greater compaction. Where ponding or flooding is used for a maximum settlement, adequate dikes will be constructed to retain the water. Where jetting is used, the jets shall be of sufficient length to reach the bottom of each layer and the water supply shall be continuos. ❑ R18 COMPACTION TESTS: If so required by the inspector, compaction test shall be made at intervals of not more than one - thousand (1000') feet and a maximum of one (1) test on each road. One (1) copy of each test shall be forwarded tot the City Engineer for approval and filed prior to making permanent repairs. Compaction tests shall be made as outlined in Section 6.3.01 of the Standard Specifications, Division of Highways, State of California, dated January 1973. ❑ R19 COMPACTION TESTS: If so required by the Inspector, compaction tests shall be made for each crossing or service line. One (1) copy of each test shall be forwarded to the City Engineer for approval and filed prior to making permanent repairs. Compaction tests shall be made as outlined in Sections 6.3.001 of the Standard Specifications, Division of Highways, State of California, dated January 1973. ® R20 TEMPORARY PAVEMENT REPAIRS: After completion of backfill and compaction operations, a temporary patch consisting of two inches (2") of SC-800 shall be placed on a prepared sub -grade. The SC-800 temporary paving shall be placed after a maximum of three -thousand linear feet (3000') or trench has been excavated and backfill operations completed, but in no case shall the placement of the temporary pavement exceed a five (5) day limit. ® R21 PERMANENT PAVEMENT REPAIR: After backfill and compaction have been completed, a temporary patch consisting of two inches (2") of SC-800 shall be placed immediately. A permanent patch of ( " N/A " ) inches of A.0 surfacing placed on a ( " N/A ") inch ( crushed ) aggregate base shall be placed no later than ( 5 ) days after completion of temporary road repair. ❑ R22 FOG SEAL: A fog seal coat consisting of an application of asphaltic emulsion shall be applied over all patch areas as determined by the City Engineer. ® R23 STREET RESTRIPING: Where street striping is still visible on street to be excavated, such striping shall be replaced upon completion of permanent repairs. ® R24 TREE RELOCATION OR REMOVAL: Tree relocation within the City of La Quinta road right-of-way shall be accomplished by a licensed, bonded and insured tree service, and handled safely without interference or hazard to the traveling public. It shall be the responsibility of the permitte to maintain the tree in a vigorous growing condition at its new location. Trees to be removed shall be in sections, which can be handled safely without interference or hazard to highway traffic. The entire width of the tree stump, shall be removed and disposed of so that no debris remains in view of the highway. The stump hole shall be backfilled and thoroughly compacted as specified in the following paragraph. Where it becomes necessary to restrict traffic, the work shall be restricted to a maximum of five -hundred feet (500') at any one time. Adequate signs, flagmen and or barricades shall be provided to protect the traveling public at all times. Large holes resulting from tree removal shall be backfilled and compacted to not less than ninety percent (90%) or equivalent tot the surrounding ground, whichever is the greater compaction as determined by the impact or field method. Compaction tests shall comply with Section 6.3.01 of the Standard Specifications, Division of Highways, State of California, dated January 1973. x- a I - " PERMIT NO.5105 Mirage of La Quinta II / Onsite Street & Storm Drain / Tract No. 32279 In addition to the standard permit conditions, the following shall apply: Pursuant to Section 14.16.320 of the La Quinta- Municipal Code (Ordinance 10 § 1 (part), 1982), all work shall be performed in accordance with the latest edition of the Standard Specifications For Public Works Construction (SSPWC) and as directed by and to the satisfaction of the City Engineer. 2. This permit or copy of it shall be on the work site (usually the job trailer) for inspection during the actual work performed. 3. Standard Pacific Homes, (Contact Rosie Lara a), 218-8258), hereinafter referred to as "Permittee", shall be responsible for providing continuous dust and erosion control. 4. Streets shall be kept clean. They shall be completely cleaned at the end of each working day and more frequently, if required. 5. Pursuant to Section 6.08.050 of the La Quinta Municipal Code (Ordinance 18 § 1,1982), throughout the work site, the Permittee shall comply with City regulated work hours. Operation and maintenance of equipment within one-half mile of human occupancy shall be performed only during the following time periods: October 1st to April 30: Monday -Friday 7:00 a.m. to 5:30 p.m. Saturday 8:00 a.m. to 5:00 p.m.. May 1 st to September 30: Monday -Friday 6:00 a.m. to 7:00 p.m. Saturday 8:00 a.m. to 5:00 p.m. Work shall be prohibited on legal holidays and Sundays Note: Construction work (including setting up traffic control devices) is not permitted on any Arterial street (ie any 4 lane street) before 8:00 a.m. 6.. The permittee and/or contractor placing engineered fill must provide adequate time and safety for the Geotechnical Engineer of Record to perform soils testing during engineered fill placement. The testing frequency shall be determined by the Geotechnical Engineer of Record such that the fill -can be determined to be placed according to the city approved plans. 7. The permittee and/or contractor shall provide surveyor staking information adequate for the City Inspector to determine horizontal and vertical locations relative to the approved city plans. The minimum required wood lath type stakes shall be placed at all proposed building corners, and they shall state the horizontal location relative to building corner and the elevation of the top of hub next to the lath. Special Conditions Page 1 of 5 PERMIT NO.5105 Mirage of La Quinta II / Onsite Street & Storm Drain / Tract No. 32279 8. Pursuant to Section 14.16.110 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), Permittee shall assume responsibility for repair of any pavement damage to any public or private street and for any damage to other City streets or facilities as a result of work performed under this permit. 9. Any land on which Williamson Act contracts apply shall remain undisturbed. 10. Pursuant to Section 14.16.250 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), advance warning signs and traffic control shall be installed and maintained in accordance with Cal Trans Standards or the Work Area Traffic Control Handbook (WATCH Manual). A traffic control plan shall be prepared in accordance with the WATCH Manual and submitted to the City for review and approval one (1) week prior to starting any construction. It shall be the Permittee's responsibility to appropriately.detour and barricade all construction sites. Pursuant to Section 14.16.290 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), street closures shall not be permitted. A minimum of two (2) travel lanes of paved surface shall be maintained at all times. 11. Prior to excavating, if required, the Permittee shall contact Underground Service Alert at 1-800-422- 4133. It shall be the Permittee's responsibility to notify the Public Works Department of anticipated excavation which impact City facilities, including but not limited to traffic signal conduits and loops, irrigation lines, electrical conduits, and storm drain facilities. 12. Should additional work, materials, or modifications of the work be required in order to meet City standards, safety requirements, signage requirements, or to fit actual field conditions, the work shall be performed by the Permittee as directed by and to the satisfaction of the City Engineer at no cost to the City of La Quinta. 13. The permittee shall be responsible for calling the city inspector to arrange the city inspector to observe random trench compaction testing performed by a city approved material testing firm. If the inspector's phone number is unknown, the permittee shall call the Public Works front counter phone at 777-7075 or the Associate Engineer at 777-7089 to determine the city inspector's phone number. The inspector shall determine the number and location of the test location/s. The above testing does not relieve the permittee's responsibility for future repairs due to settlement at and near the locations of the work area. Materials testing must be performed under direct supervision of a California Registered Civil Engineer. 14. The issuance. of this permit and the City approval of the related construction improvement plans do not provide a vested entitlement for all design parameters that may have been utilized for the plans. As such, plans approved for this permit may be "at risk" for further modifications as it relates to any follow up improvement plan requirements as required by the city or existing errors & omissions by the architect or engineer of record. Special Conditions Page 2 of 5 PERMIT NO.5105 Mirage of La Quinta II / Onsite Street & Storm Drain / Tract No. 32279 15. This permit is not valid until the permittee submits, to the Public Works Department 2 weeks prior to start of construction, the name of the City approved contractor, who shall submit to the Citythe following items: a. General Liability Insurance Company and Policy Number b. City Business License c. Contractors State License Number 16. The permittee shall not encroach upon private property without prior written approval (submit to the Public Works Department, attention to the Associate Engineer) of the private land owner whom ' is being encroached upon. 17. Prior to performing construction work and closing any lanes in the Public Right of Way, the permittee shall call the City at (760) 777-7097 at least 48hrs prior to work and request an appointment for a preconstruction meeting with the City Inspection staff. 18. The permittee shall haul all offsite debris to a certified landfill. Prior to hauling debris, the permittee shall inform the City (Inspection staff or 777-7089) of the name and location of the certified dump site. 19. Pursuant to Section 14.16.370 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), backfill compaction within street rights -of -way shall conform to Section 306-1.3 of the latest edition of the Standard Specifications for Public Works Construction (SSPWC), except as otherwise specified herein. Native material may be used as backfill material provided that minimum compaction, achieved in the manner prescribed herein, is achieved. Backfill shall be performed by mechanical means; no water densified compaction via jetting or flooding or other means shall be allowed. It shall be the Permittee's responsibility to provide appropriate geotechnical supervision, testing, and inspection, onsite, at all times during backfill operations. Backfill compaction shall be achieved by the following conditions: A. When a firm foundation is not encountered due to soft, spongy or other unsuitable material, such material shall be removed to the limits directed by the Geotechnical Inspector and/or the City Inspector and the resulting excavation backfilled with pipe bedding material. B. Backfill materials shall be brought to or maintained at appropriate moisture content for compaction. The appropriate moisture content range shall be established at the onset of the project and ensured prior to use of the materials through progress testing on the stockpiles. C. The first length of trench backfilled shall be backfilled in the presence of the City Inspector. Compaction shall be tested at random depths at approximate three-foot vertical intervals as backfill is placed to ensure the effectiveness of the compaction methods and to establish the depth of lift that can be compacted. D. If lifts greater than one foot are attempted in this trial length of trench, compaction tests shall be taken within the lifts to ensure that the full depth of the lift is compacted. Upon satisfactory Special Conditions Page 3 of 5 PERMIT NO.5105 Mirage of La Quinta II / Onsite Street & Storm Drain / Tract No. 32279 completion of this portion of trench, the City Inspector shall establish the maximum lift thickness to be compacted for the remainder of the project. E. In subsequent lengths of trench, the frequency of compaction tests shall equal one per each lift of backfill, per 300 linear feet of open trench, at randomly selected locations within the open length of trench. F. The depth of the randomly selected compaction tests shall also be randomly selected except that where multiple tests are required in a given length of trench, the tests shall be no closer than three feet (vertically) from each other. G. If any compaction test fails, previously placed backfill (in the same length of open trench or previous lengths of trench) which is represented by the failing test (as determined by the City Inspector), shall be tested for compliance with compaction requirements. H. All costs incurred due to the conditions above shall be borne by the Permittee. Copies of all test results shall be furnished to the City Inspector. 20. All excavations within City of La Quinta right-of-way shall be backfilled, and temporarily paved if within the existing travel way, at the end of every workday as directed by and to the satisfaction of the City Engineer for the protection of the public. Lengths of open trench shall not greatly exceed that which can not be backfilled in the same day. Excavated trenches shall not be allowed open overnight; however, Permittee may leave a length of excavated trench, not to exceed twenty (20) feet in length, open overnight at a point where construction.will begin the next day, provided that this length of trench. is completely covered by steel plating. 21. All landscaping, irrigation, decorative rock, decorative concrete, lighting, etc., shall be replaced to its original condition. 22. Access and egress to all local properties shall be maintained at all times. 23. Pursuant to Section 14.16.375 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), permanent pavement replacement shall be completed no later than seven (7) days after the completion of the work. Permanent pavement replacement shall conform to the following conditions: A. Existing asphalt concrete pavement shall be sawcut one (1) foot beyond trench edges. Edges shall be straight and clean. B. Permanent pavement replacement structural section, within all trenches, shall be 1" thicker than existing of asphalt concrete over the same existing thickness of crushed aggregate base or crushed miscellaneous base, meeting the requirements of Sections 200-2.2 and 200-2.4 of the Standard Specifications for Public Works Construction. The replaced pavement and base material shall be compacted to 95% relative compaction and respectively tested, for each 300 linear feet of trench. Verify exact structural replacement section thicknesses with the City prior to installation. Special Conditions Page 4'of 5 PERMIT NO.5105 Mirage of La Quinta II / Onsite Street & Storm Drain / Tract No. 32279 C. Permanent pavement replacement shall be installed using a City approved 3/" max medium asphalt concrete as the base course lift and a City approved'/2" max medium finish course lift for capping. Asphalt concrete mix design shall be approved by the City prior to its placement. D. Cold -Mill and Overlay - The existing pavement which was properly protected in place during the trenching operation located adjacent to the trench saw cut shall be cold -milled to a depth of 0.10 feet with butt joint created next to the existing unmilled pavement surface. The cold -milled area and base asphalt concrete in the trench area shall be overlaid with a City approved C2-AR-4000 asphalt concrete mix. The width of the cold, milling area shall be as follows: • For longitudinal trenches located in a parking lane: three (3) feet outside the sawcut removal lines. • For longitudinal trenches located in a traffic lane: three (3) feet outside the sawcut removal lines, or to the lane line striping, whichever is greater. • For transverse trenches across existing street: two (2) feet outside the sawcut removal lines. E. If grinding and capping operations are not performed in the same day as base paving operations, the base course. lift of 3/" max medium asphalt concrete shall be installed from saw -cut edge to saw -cut edge flush with the existing street surface. The base course lift of paving shall not be left 0.10' low in anticipation of grinding and capping. F. Any existing lane striping or any existing detour lane striping affected by this resurfacing shall be replaced in kind by the Permittee, as directed by and to the satisfaction of the City Engineer. Affected traffic signal loops shall be removed and replaced in kind. The finished pavement surface shall be smooth, consistent, and shall conform to the surrounding grades. 24. Permittee shall permanently stabilize any and all soil that was disturbed as a result of work performed under this permit with an approved dust control treatment. Soil stabilization shall be done immediately after completing the operation. 25. Pursuant to Chapter 12.56 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982) the City has designated certain city streets as Truck Routes. The weight limit for restricted streets (i.e., streets not part of the Truck Route network) is three (3) tons; trucks exceeding the weight limit may use a restricted street if making a delivery or pickup on the subject street, or if this permit specifically grants permission to use the street to deliver street construction materials and/or equipment. 26. The City of La Quinta reserves the right to revoke, suspend or void this permit at any time. 27. The permittee shall .indemnify, hold harmless and assume the defense of the City from all damages, delay costs, costs or expenses in law or equity that may arise out of work under this permit. 28.. If it is the intent of the permittee to cut the pavement and have it restored by a third party, the permittee shall postpone cutting the pavement until the intended third party has acquired a permit from the City to perform the required restoration work. Special Conditions Page 5 of 5 .0 . 41