Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BRES2019-0001
4vaal�lfm 78-495 CALLE TAMPICO LT VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT ate: 1/22/2019 Permit Type/Subtype: BUILDING RESIDENTIAL/ADDITION Owner: Application Number: Property Address: BRE52019-0001 79045 COYOTE CREEK DOUGLASS VANCE 79045 COYOTE CREEK. APN: 776030023 LA QUINTA, CA 9:225311. Application Description: VANCE / 499 SF ADDITION' Gd] Property Zoning: Application Valuation: $35,000.00�' r � r Applicant: Contractor: DOUGLASS VANCE DOUGLASS VANCE: 79045 COYOTE CREEK 79045 COYOTE CRE C: LA QUINTA, CA 92253 LA QUINTA, CA 922 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: _CONV:144528101254105125 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars rl', as owner of the property, or my employees with wages as them• sale compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that hJqp she did not build or improve for the purpose of sale.). } 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to PZ)tractors' State License Law.).m exempt under 5ec. . B.&P.C,; for this reason Date: 2� Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.), Lender's Name: Lender's Address: (760)963-3427 Llc. No.::CONV:140528101254105126 WORKER'S COMPENSATION DECLARATION I here affirm under penalty of perjury one of the following declarations: cor�l have and will maintain a certificate of consent to self -insure for workers' Ion, as provided for by Section 3700 of the Labor Code, for the performance of tholwork for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carr's Policy Number: 1. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree th t, If I should become subject to the workers' compensation provisions of Section 0 of the de, I shall forthwith comply with those provisions. to Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and stat aws relating to building construction, and hereby authorize representatives of this ci den on the above -mentioned pr�operty for inspection purposes. Date: 1 ■ Signature (Applicant arAgen Date: 1/22/2019 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: DOUGLASS VANCE 79045 COYOTE CREEK LA QUINTA, CA 92253 BRES2019-0001 79045 COYOTE CREEK 776030023 VANCE / 499 SF ADDITION $35,000.00 Owner: DOUGLASS VANCE 79045 COYOTE CREEK LA QUINTA, CA 92253 Contractor: DOUGLASS VANCE 79045 COYOTE CREEK LA QUINTA, CA 92253 (760)963-3427 Llc. No.::CONV:140528101254105126 Detail: 499 SF CASITA ADDITION WITH WALK IN CLOSET. THIS INCLUDES NEW HVAC AND WATER HEATER AT CASITA. 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNT CITY AMOUNT ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $68.84 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $19.21 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF 101-0000-42400 0 $134.48 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF PC 101-0000-42600 0 $188.92 Total Paid for ADDITION: $411.45 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $2.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES/FIXTURES, ADDITIONAL 101-0000-42403 0 $56.07 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES/FIXTURES, ADDITIONAL PC 101-0000-42600 0 $14.07 Total Paid for ELECTRICAL: $123.50 DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($10.28 ) DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($26.68) DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $40.02 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE 101-0000-42402 0 $10.28 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE 101-0000-42402 0 $29.74 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE PC 101-0000-42600 0 $26.68 Total Paid for MECHANICAL: $96.44 DESCRIPTION ACCOUNT QTY AMOUNT PLAN CHECK DEPOSIT - ADDITION/REMODEL 101-0000-42600 1 $125.00 Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00 DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($13.34) DESCRIPTION ACCOUNT CITY 4MOUNT 101-0000-42600 ($13.34) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($13.34) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($26.68) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($13.34) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($8.00) DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $8.00 Total Paid for PLUMBING FEES: $0.00 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $4.55 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $4.55 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 tev0"(ra PERMIT # 'J k( S , J 0 0) PLAN LOCATION: Project Address: 7� d ®()7oL �� Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: — O v D Zi r Applicant Name: Address: 7 6--e0 o "d a' City, ST, Zip: �c Telephone: (12 7 Email: r Valuation of Project $ c ,nq V Contractor Name: Address: City, St, Zip Telephone: Email: State Lic: City Bus Lic: �A e New SFD Construction: Conditioned Space SF Garage SF Patio/Porch SF Fire Sprinklers SF Arch/Eng Name: &Lir L4 Construction Type: Occupancy: Address: Grading: City, St, Zip MAL, AA Telephone: O Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: ` New Commercial / Tenant Improvements: — 6-1.4 t-11a Address: AA Total Building SF City, ST, Zip Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal Req'd Rec'd Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License Date: 1/17/2019 No.: 19-01229-1 Owner: Douglas Vance Address: 79045 Coyote Creek City: La Quinta Type: Detached Guest House Lot # Street No. 79045 Comments: CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 41 47950 Dune Palms Road 01 aFH.a,)ppuritsr R"mo�,�i[aI E G r xvow� La Quinta, CA 92253 y Z (760)771-8515 �[N kLl7n y�` Email: Jurisdiction: La Quinta Tract #: Street Name Sq. Feet APN Permit No. Coyote Creek 499 776-030-023 At the present time, the Desert Sands Unified school District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.79 X 499 S.F. or $1,891.21 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: MCJGwen K Vance Check No.: Credit / Debit Card Bank Name/Recipient of Certificate Telephone: 760-413-0584 Funding: Residential By Scott L. Ba i I ey Superintendent Fee Collected/ Exempted by: Arianne Catano Certificate Fees Due: $1,891.21 Credit Card Fees Due; $37.82 Original Payment(s) Rec'd: $0.00 New Payment Rec'd: $11929.03 Over/Under: $0.00 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. T44f 4 4 a" P.O. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT PROPERTY OWNER'S PACKAGE (760)777-7012 FAX (760) 777-7011 Disclosures & Forms for Owner -Builders Applying for Construction Permits IMPORTANT! NOTICE TO PROPERTY OWNER Dear Property Owner: An application for a building t has bee subnvtte in y ur name listing yourself as the builder of the property improvements specified at We are providing you with an Owner -Builder Acknr'wl gment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION — IRECTI�NS: Read and initial each statement below to signify you understand or verify this information. 1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder" building pemut that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property, My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers a my property. 2. I understand building permits are not required to be signed by property owners unless they are responsible for the ktion and are not hiring a licensed Contractor to assume this responsibility. understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect yrom potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my 0 4. I understand Contractors are required by law to be Iicensed and bonded in California and to list their license numbers on p is and contracts. 5. 1 understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars (S500), including labor and materials, I may be considered an "employer" er state and federal law. G. I understand if I am considered an "employer' under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee," I also understand my failure to abide by these laws may subject me to serious financial ri 7understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. $. I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the I,4 manship or materials. 9. I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue ee, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1- $ -3 -CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. 10. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the party legally^ and finaneia% responsible for proposed construction activity at the following address: 911. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all Vve1le lawsand requirements that govern Owner -Builders as well as employers. . I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I ovided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held 'liable for damages. if you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for iss ing be permit. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable o tl a agent is required to be presented when the permit is issued to verify the property owner's signature. t� � 4.. Signature of property o� Date: Z- r Note: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S SEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agents) to apply for, sign d file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: I < 6 Y� Name of Authorized Agent: Address of Authorized Agent: TPl Nn y ` V� 7 C I declare under penalty of perjury t t am the property owner for the address listed above and I personally filled out the above information and certify its accuracy ate: A copy of the owner's driver's license, form notarization, or other verification acceptable to the agency�isrequhre to b nted when the permit is issued to verify the property owner's signature. Property Owner's Signa CL:�_ Date: f Building Permit Number: Project Description: room addition Exempt: ❑ (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Plan Submittal Date 1/18/2019 Job Site Owner's Name Number, Street, or PO Box City, State, Postal Code Owner's Phone Number Owner's E-Mail Address Project Manager's Name Project Manager's Phone Number Project Manager's E-mail Address 79045 Coyote Creek Douglas & Gwen Vance 79045 Coyote Creek La Quinta, CA. 92253 c/o 760-902-0827 Jeff Paige 760-902-0827 jvpai e1 venzoLl et Builder / Contractor Owner/Builder Number, Street or PO Box 79045 Coyote Creek City, State, Postal Code La Quinta, CA. 92253 Project Square Footage Approx. 499 sq ft City Approval By Renado Gouldlock-DECBurrtec Waste' .� Date of City Approval o 1 Materials To Be Discarded: Product Tons Trash 1.80 Not recyclable Asphalt 0.00 Recyclable Brick/Block 0.00 Recyclable Cardboard 0.00 Recyclable Commingled 0.00 Recyclable Concrete I 2.00 Recyclable Drywall 0.20 Recyclable Donated / Reuse` 0.00 Recyclable "Describe Items Totals: Recycle Trash 3.5 1 1.8 Product Tons Masonry (broken) 0.00 Plaster 0.50 Scrap Metal 0.00 Tile (floor) 0.05 Tile (roof) 0.06 Wood 0.70 Landscape Debris 1 0.00 Projected Diversion: 66.10% I understand It Is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is diverted from landfIIli ng. The remaining material will be recycled or reused. I will divert, for recycling or w-use, remaining materials generated from the first day of the project through the completion or the project in accordance with this plan. This DMP is issued in the name of the property owners) and shall remain Iheir properly throughout the construclIon and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property owner(s) and the owner relains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer Owner / Dove oper / Project Manager! Superintendant Date CITY OF LA QUINTA SUI3- ONTRACTOR_LI T JOB ADDRESS ` co� PERMIT NUMBER 2'eDkq"-_ NNER Q-u_ Vr--E --BUILDER This forum shall be pasted an the job with the Building Inspection Card at all times in a conspiOnly peY4ons appearing on this list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance of hidir inn nPrmit_ For Parh annlicahle trade_ all information renuPsted hPlnw must he cmmn!eted by anolicant. "On File" is not an acceptable response. Trade 1 Classificatfon Contractor State. Contractor's License workers Compensation Insurance City Business License Company Name Classification (e.g. A, B, C-8) License Number (xxxxxx) Exp. Date (xx/xx/xx) Carrier Name (e.g. State Fund, CalComp) Policy Number (Format Varies) Exp. Date License Number (xx/xx/xx) (xxxx) Exp. Date (xx/xx/xx) EARTH WORK (.C=12) © ��. � �` 45-yd wecct'a s v��cA Got _� Q 16 r, CONCRETE (C-8) 09AS A 8 ti6s y 8 b -�-�-a WVJC, n a Iq FRAMING:(C-5) Yls gvcC 1 an —1 l7 l ` 3--o-10 t�,cd W'10 11) I S STRUGT. STEEL:(0: 511 MASONRY (C 29) - PLUMBING (C-36) LATH, PLASTER (0=35): DRYWALL(C-9:) ` 4�1VP. �u\AL ,�RL�v�lffl�s I 1 i q HVAC (C-20): S oL +� �� 1 l� �- �7 ���'�Q t� �� �1 V t'��L_ ' S lJ lti1 L- 9f �- S3 V �1 1: [ ^ E�\��``i�J •)ilC ELECTRICAL (C-10)�' 1^(1 ] � �di�u� N� �7�,t'r�c c1 j-I i )� U" ! l� 0 0 ROOFING (C-39): SHEET METAL (C-43) FLOORING (C-15:). GLAZING (C-77) N\.iRo 3 1C ktmi 0( 05)1 1-1—�o ukc,,V�Rq ` I INSULATION (C-2) SEWAGE DISP:.(C-421 PAINTING(C-3:3.) �'RC4,\ \� j 1 ,��Q� vrT�`�1 JaC{ N)tVJC9©-W ` �J CERAMIC TLLE (.C-54:) CABINET$ (C-6). LL,,, i G-�'�VM LVSIVm ( YI \ G ��-`-1L1. j'` I � Pt i �+ W FENCING (C43) LANDSCAPING (.C-27). POOL (C-53) BUILDING ENERGY ANALYSIS REPORT �ze 1,q-arot C-J-A� PROJECT: Vance Residence Addition 79-045 Coyote Creek La Quinta, CA 92253 Project Designer: Barry Brett White P.O. Box 10463 Palm Desert, CA 92255 (760) 861-8146 Report Prepared by: CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE Tim Scott I- Scott Design and Title 24, Inc, 74-818 Velie Way, Suite #8 Palm Desert, CA 92260 (760) 200-4780 Job Number: Date: 12/26/2018 BY .-% 1�tc'ENED Cl DF MENT COMML)NIV DEVELOP The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. I TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01-E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 12 Form MF-1 R Mandatory Measures Summary 15 HVAC System Heating and Cooling Loads Summary 19 Zone Load Summary 22 CERTI( TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: Vance Addn Calculation Description: Title 24 Analysis HOD Calculation Date/Time: 13:47, Wed, Dec 26, 2018 Input File Name: Vance Addn LQ-Coyote Creek.ribd16x CF ?RF-01 Page 1 of 9 GENERAL INFORMATION 01 Project Name Vance Addn 02 Calculation Description Title 24 Analysis 03 Project Location 79-045 Coyote Creek 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 180 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ftZ) 4457 15 Number of Zones 4 16 Slab Area (ftZ) 4457 17 Number of Stories 1 18 Addition Cond. Floor Area (ft) 480 19 Natural Gas Available Yes 20 Addition Slab Area (ft) 480 21 Glazing Percentage (%) 17.6% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ftZ-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 1.06 0.99 0.07 1 6.6% Space Cooling 175.11 175.23 -0.12 -0.1% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 7.24 7.00 0.24 3.3% Photovoltaic Offset ---- 0.00 0.00 -- Compliance Energy Total 183.41 183.22 0.19 0.1% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. NO SPECIAL FEATURES REQUIRED Registration Number: 218-P010336003A-000-000-0000000-0000 Registration Date/Time: 2018-12-26 14:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-26 13:47:55 CERTI( TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE' 'HOD CF IRF-01 Project Name: Vance Addn Calculation Date/Time: 13:47, Wed, Dec 26, 2018 Page 2 of 9 Calculation Description: Title 24 Analysis Input File Name: Vance Addn LQ-Coyote Creek.ribdl6x HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Refrigerant Charge verification required if a refrigerant containing component is altered HVAC Distribution System Verifications: • Duct Sealing • Duct Sealing required if a duct system component, plenum, or air handling unit is altered Domestic Hot Water System Verifications: -- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Vance Addn 4457 1 15 4 0 2 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Living Zone Conditioned HVAC-Livingl 2494 11.5 DHW Sys 1 n/a Sleeping Zone Conditioned HVAC-Sleeping2 1483 10.5 DHW Sys 1 n/a Closet Addition Conditioned HVAC-Sleeping2 172 10 DHW Sys 1 n/a New Casita Zone Conditioned HVAC-Casita3 308 10 DHW Sys 3 n/a Registration Number: 218-P010336003A-000-000-0000000-0000 Registration Date/Time: 2018-12-26 14:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-26 13:47:55 CERTIi, TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: Vance Addn Calculation Description: Title 24 Analysis HOD Calculation Date/Time: 13:47, Wed, Dec 26, 2018 Input File Name: Vance Addn LQ-Coyote Creek.ribdl6x CF JRF-01 Page 3 of 9 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ftZ) Tilt (deg) Wall Exception Status Verified Existing Condition N Wall Living Zone Existing Wall 0 Back 562 48 90 n/a Existing No E Wall Living Zone Existing Wall 90 Right 570 79 90 n/a Existing No S Wall Living Zone Existing Wall 180 Front 658 378.2 90 n/a Existing No W Wall Living Zone Existing Wall 270 Left 180 58.4 90 n/a Existing No Roof 3 Living Zone Existing Roof 2494 n/a Existing No N Wall 2 Sleeping Zone Existing Wall 0 Back 360 22 90 n/a Existing No E Wall 2 Sleeping Zone Existing Wall 90 Right 285 48 90 n/a Existing No S Wall 2 Sleeping Zone Existing Wall 180 Front 346 64 90 n/a Existing No W Wall 2 Sleeping Zone Existing Wall 270 Left 688 16 90 n/a Existing No Roof 4 Sleeping Zone Existing Roof 1483 n/a Existing No N Wall 3 Closet Addition R-21 Wall 0 Back 80 0 90 none New n/a W Wall 3 Closet Addition R-21 Wall 270 Left 215 0 90 none New n/a Interior Surface Closet Addition»New Casita Zone R-0 Interior Wall 80 0 n/a New n/a Roof 5 Closet Addition R-38 Roof Attic 77.3 n/a New n/a E Wall 3 New Casita Zone R-21 Wall 90 Right 195 72 90 none New n/a S Wall 3 New Casita Zone R-21 Wall 180 Front 133 0 90 none New n/a W Wall 4 New Casita Zone R-19 Wall (W. 1 9.2x6.16) 270 Left 195 0 90 none New n/a Interior Surface 2 New Casita Zone»Closet Addition R-0 Interior Wall 80 0 n/a New n/a Roof 6 New Casita Zone R-38 Roof Attic 307.65 n/a New n/a OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 11 12 Name Zone Type Orientation Area (ft) Skylight Area (ft2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Status Verified Existing Condifion Roof Closet Addition R-38 Roof Atticl Left 0.8 0.7 0 0.1 0.85 No New n/a Roof 2 New Casita Zone R-38 Roof Atticl Left 0.45 0.35 3 0.1 0.85 No I New n/a Registration Number: 218-P010336003A-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2018-12-26 14:03:38 Report Version - CF1 R-06232018-1149 HERS Provider: CaICERTS inc. Report Generated at: 2018-12-26 13:47:55 CERT[ LTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: Vance Addn Calculation Description: Title 24 Analysis 'HOD Calculation Date/Time: 13:47, Wed, Dec 26, 2018 Input File Name: Vance Addn LQ-Coyote Creek.ribdl6x CF ?RF-01 Page 4 of 9 ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance i Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Living Zone Attic RoofLiving Zone Ventilated 3 1 0.1 0.85 No No Existing No Attic Sleeping Zone Attic RoofSleeping Zone Ventilated 3 0.1 0.85 No No Existing No Attic Closet Addition Attic RoofCloset Addition Ventilated 0 0.1 0.85 Yes No New No Attic New Casita Zone Attic RoofNew Casita Zone Ventilated 3 0.1 0.85 Yes No New No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft) U-factor SHGC Exterior Shading Status Verified Existing Condition Exist. Win. N Wall (Back-0) - 1 48.0 0.71 0.60 Insect Screen (default) Existing No Exist. Win. 2 E Wall (Right-90) - 1 64.0 0.71 0.60 Insect Screen (default) Existing No Exist. Win. 3 E Wall (Right-90) 1 4.5 0.71 0.60 Insect Screen (default) Existing No Exist. Win. 4 E Wall (Right-90) - 1 4.5 0.71 0.60 Insect Screen (default) Existing No Exist. Win. 5 E Wall (Right-90) 1 6.0 0.71 0.60 Insect Screen (default) Existing No Exist. Win. 6 S Wall (Front-180) - 1 30.0 0.71 0.60 Insect Screen (default) Existing No Exist. Win. 7 S Wall (Front-180) - 1 80.0 0.71 0.60 Insect Screen (default) Existing No Exist. Win. 8 S Wall (Front-180) 1 215.0 0.71 0.60 Insect Screen (default) Existing No Exist. Win. 9 S Wall (Front-180) 1 53.2 0.71 0.60 Insect Screen (default) Existing No Exist. Win. 10 W Wall (Left-270) - 1 58.4 0.71 10.60 Insect Screen (default) Existing No Exist. Win. 11 N Wall 2 (Back-0) - - 1 16.0 0.71 0.60 Insect Screen (default) Existing No Exist. Win. 12 N Wall 2 (Back-0) - 1 6.0 0.71 0.60 Insect Screen (default) Existing No Exist. Win. 13 E Wall 2 (Right-90) 1 48.0 0.71 0.60 Insect Screen (default) Existing i No Exist. Win. 14 S Wall 2 (Front-180) - -- 1 64.0 0.71 0.60 Insect Screen (default) Existing No Exist. Win. 15 W Wall 2 (Left-270) - 1 16.0 1 0.71 0.60 Insect Screen (default) Existing No Skylight Roof (Left-270) - - 1 .4 0.30 0.30 None New n/a Skylight 2 Roof (Left-270) - - 1 .4 0.30 0.30 None New n/a New Win. E Wall 3 (Right-90) - -- 1 48.0 0.38 0.23 Insect Screen (default) New n/a New Win. 2 E Wall 3 (Right-90) - - 1 24.0 0.38 10.23 1 Insect Screen (default) New n/a Skylight 3 Roof 2 (Left-270) - 1 .4 0.30 1 0.30 1 None New n/a Registration Number: 218-P010336003A-000-000-0000000-0000 Registration DateMme: 2018-12-26 14:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-26 13:47:55 CERTi ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE HOD Project Name: Vance Addn Calculation Date/Time: 13:47, Wed, Dec 26, 2018 Calculation Description: Title 24 Analysis Input File Name: Vance Addn LQ-Coyote Creek.ribdl6x CF ;'RF-01 Page 5 of 9 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofLiving Zone Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Existing Roof attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 30 0.032 Over Ceiling Joists: R-20.9 insul. • Inside Finish: Gypsum Board R 19 in 5-1/2 in. Cavity/Frame: R-19 in 5-1/2 in. (R-18) /2x6 Existing Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. cavity (R-18) 0.074 Exterior Finish: 3 Coat Stucco • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofSleeping Zone Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofCloset Addition Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-38 / 2x4 • Roof Deck: Wood Siding/sheathing/decking R-38 Roof Atticl Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.041 Roofing. Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Sheathing/Insulation: R5Sheathing • Cavity/Frame: R-21/2x6 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.048 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 R-0 Interior Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.277 Other Side Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofNew Casita Zone Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board R 19 in 5-1/2 in. Cavity/Frame: R- 19 in 5-112 in. (R-18) /2x6 R-19 Wall (W.19.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. cavity (R-18) 0.074 Exterior Finish: 3 Coat Stucco Registration Number: 218-P010336003A-000-000-0000000-0000 Registration Date/Time: 2018-12-26 14:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-26 13:47:55 CERT( ,TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 7HOD Project Name: Vance Addn Calculation Date/Time: 13:47, Wed, Dec 26, 2018 Calculation Description: Title 24 Analysis Input File Name: Vance Addn LQ-Coyote Creek.ribd16x CF pRF-01 i Page 6 of 9 SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value Carpeted Fraction Heated Status Verified Existing Condition Slab -on -Grade Living Zone 2494 189 None 0.8 No Existing No Slab -on -Grade 2 Sleeping Zone 1483 189 None 0.8 No Existing No Slab -on -Grade 3 Closet Addition 172 40 None 0.8 No New No Slab -on -Grade 4 New Casita Zone 308 54 None 0.8 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 2 0 Existing No DHW Sys 3 DHW Standard DHW Heater 3 1 0 1 New No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Input Rating / Tank Standby Heater Tank Uniform Energy Pilot / Insulation Loss / First Hour Tank Location Element Number Volume Factor / Energy Thermal R-value Recovery Rating / NEEA Heat Pump or Ambient Name Type Tank Type of Units (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Brand / Model Condition DHW Heater 1 Gas Small Storage 2 50 0.61 EF <= 75 kBtu/hr 0 n/a n/a n/a n/a DHW Heater 3 Gas Small 1 0 0.96 EF <= 200 kBtu/hr 0 n/a n/a n/a n/a Instantaneous Registration Number: 218-P010336003A-000-000-0000000-0000 Registration DateMme: 2018-12-26 14:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-26 13:47:55 CERT( XE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: Vance Addn Calculation Description: Title 24 Analysis 'R� Calculation Date/Time: 13:47, Wed, Dec 26, 2018 Input File Name: Vance Addn LQ-Coyote Creek.ribdl6x CF ?RF-01 Page 7 of 9 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 Distribution Verified Existing SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Name Status Condition HVAC-Livingl Other Heating and Cooling Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution Existing No System System 1 HVAC-Sleeping2 Other Heating and Cooling Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution Altered No System System 2 HVAC-Casita3 Other Heating and Cooling Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution New No System System 3 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 2 CntrlFurnace 1 80 AFUE Heating Component 3 CntrlFurnace 1 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 2 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 2-hers-cool Cooling Component 3 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 3-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 2-hers-cool Required 350 Required Required Not Required Cooling Component 3-hers-cool Required 350 Required Required Required Registration Number: 218-Po10336003A-000-000-0000000-0000 Registration Date/Time: 2018-12-26 14:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-26 13:47:55 CERT.! LTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: Vance Addn Calculation Description: Title 24 Analysis •oa Calculation Date/Time: 13:47, Wed, Dec 26, 2018 Input File Name: Vance Addn LQ-Coyote Creek.ribd16x CF ?RF-01 Page 8 of 9 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R-value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not System 1 (Ventilated and specified) 6.0 Attic Attic None Existing No n/a Unventilated) Ducts located in attic Air Distribution Air Distribution (Ventilated and Sealed and tested 8.0 Attic Attic None Altered No System System 2 Unventilated) 2-hers-dist Air Distribution Ducts located in attic Air Distribution System 3 (Ventilated and Sealed and tested 8.0 Attic Attic None New No System Unventilated) 3-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Deeply Buried Low -leakage Name Verification Target (%) Location Design Ducts Ducts Air Handler Air Distribution System 2-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 3-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a HVAC - FAN SYSTEMS & HERS VERIFICATION 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 Required HVAC Fan 3 Single Speed PSC Furnace Fan 0.52 Required IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 0.25 Default 0 Not Required PROJECT NOTES QII - quality insulation installation- is addition only Registration Number: 218-P010336003A-000-000-0000000-0000 Registration Date/Time: 2018-12-26 14:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-26 13:47:55 CERT( TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 'HOD Project Name: Vance Addn Calculation Description: Title 24 Analysis Calculation Date/Time: 13AT Wed, Dec 26, 2018 Input File Name: Vance Addn LQ-Coyote Creek.ribdl6x CF ?RF-01 Page 9 of 9 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature- Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2018-12-26 14:03:38 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Tim Scott Company: Date Signed: Scott Design and Title 24, Inc. 2018-12-26 14:03:38 Address: License: 77085 Michigan Drive NA City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 1. r0 R L I . Easy to Verify at CaICERTS.com Registration Number: 218-P010336003A-000-000-0000000-0000 Registration DateMme: 2018-12-26 14:03:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2018-12-26 13:47:55 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Vance Residence Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family 10 Existing+ Addition/Alteration i Date 11212612018 Project Address 79-045 Coyote Creek La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,457 Addition 480 # of Units 1 INSULATION Construction Type Area Cavity ftz Special Features Status Roof Wood Framed Attic R 30 2,494 Existing Wall Wood Framed Wall Wood Framed R 19 514 R 19 491 Existing Existing Wall Wood Framed R 19 280 Existing Wall Wood Framed R 19 122 Existing Slab Unheated Slab -on -Grade - no insulation 2,494 Perim = 189' Existing Roof Wood Framed Attic R 30 1,483 Existing Wall Wood Framed R 19 338 Existing FENESTRATION Orientation Area(ft2) Total Area: 787 Glazing Percentage: 17.6 % New/Altered Average U-Factor. U-Fac SHGC Overhang Sidefins Exterior Shades 0-38 Status Rear (N) 70.0 0.710 0.60 none none Bug Screen Existing Right (E) 127.0 0.710 0.60 none none Bug Screen Existing Front (S) 442.2 0.710 0.60 none none Bug Screen Existing Left (W) 74.4 0.710 0.60 none none Bug Screen Existing Skylight 0.4 0.300 0.30 none none None New Skylight 0.4 0.300 0.30 none none None New Skylight 0.4 0.300 0.30 none none None New Right (E) 72.0 0.380 0.23 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% TE Split Air Conditioner 12.0 SEER Setback Existing 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback Altered 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status HVAC-Living Ducted Ducted Attic 6.0 Existing HVAC-Sleeping Ducted Ducted Attic 8.0 Altered HVAC-Casita Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Instantaneous Gas 0 0.96 Standard New EnerovPro 7.2 by EnerovSoft User Number: 6712 ID: Pepe 12 of 24 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Vance Residence Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1212612018 Project Address 79-045 Coyote Creek La Quinta California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 4,457 480 # of Units 1 INSULATION Construction Type Cavity Area ff Special Features Status Wall Wood Framed R 19 237 Existing Wall Wood Framed R 19 282 Existing Wall Wood Framed R 19 672 Existing Slab Unheated Slab -on -Grade - no insulation 1,483 Perim = 189' Existing Roof Wood Framed Attic R 38 385 New Wall Wood Framed R 21 551 Add=R-5.0 New Slab Unheated Slab -on -Grade no insulation 480 Perim = 94' New Demising Wood Framed no insulation 160 New FENESTRATION Total Area: 787 Glazing Percentage: 17.6 % New/Altered Average U-Factor: d-38 Orientation Area ftz U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Coolino Duct Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 7.2 by EneravSoft User Number: 6712 ID: Page 13 of 24 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Vance Residence Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1212612018 Project Address 79-045 Coyote Creek La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,457 Addition 480 # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Wall Wood Framed R 19 in 5-112 h 195 New FENESTRATION I Total Area: 767 Glazin Percents e: 17.6 % New/Altered Average U-Factor: 0.38 Orientation Area ft` U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener yPro 7.2 by EneriqySoft User Number: 6712 ID: Page 14 of 24 o , 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply. !Revised 0412011 Building Envelope Measures: § 110.6(a)l: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft' or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-201 V § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-13 for compliance and must be caulked and/or weatherstri ed.' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g), § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of .110.8 i when the installation of a cool roof is specified on the CF1 R. § 110.8Q): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.* § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U- § 150.0(c): factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.' § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This § 150.0(g)l: requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d). Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all § 150.0(g)2: insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58; or the wei. hted averse U-factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)lA: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)1 C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating! § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat: Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances. without an electrical supply voltage connection with pilot lights that consume less than 150 Btufhr are exempt): and pool and spa heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)1: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J usinq design conditions specified in § 150.0(h)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: _ Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's Instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12.extemal insulation or R-16 Internal insulation where the Internal Insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.0Q)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution piping for steam and hvdronic heatino systems or hot water systems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)36: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a as supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1 (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such toe is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier, Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m 11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labelinq requirements of § 150.0 m 12. _` � 1 '` 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <- 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RAU. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs stems' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.* § 110.4(b)1; Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off- eak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of 5 110.9.' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1 C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k).' Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(1k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 ; and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 ; and all other requirements in § 150.0 k 2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the funclonality of a dimmeraccording to § 110.8 and complies with all other applicable requirements in § 150.0(k)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with § Reference JointAppendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallwa s.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS). Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either .150.0 k 3A or with the applicable requirements in §§ 110.9 130.0 130.2 130.4 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B or § 150.0 k 3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the applicable requirements in §§ 110.9, 130.0, 130.2,130.4, 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of ower as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0 130.1,130.4 140.E and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and eqress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the req uirements of § 110.10 b thrvugh § 110.10 e , § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percpnt of the total roof area of the buildlng excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service anel)• and a pathway for routing of plumbing from the solar zone to the water -heating s stem. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 110.10(c) must be provided to the occupant, § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Vance Residence Addition 12/26/2018 System Name F€00F AFe:i HVAC-Living 2,494 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 2,191 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible output per System 890,000 43,389 3,175 1,033 37,374 Total Output (Btuh) 890,000 0 Output Btuhls ft 356.9 2,961 2,156 Cooling System 0 `0 Output per System 60,000 0 0 0 [a Total Output Btuh 60,000 0 3,175. 0 Total Output Tans 5.0 2,961 2.156 Total Output Btuhls ft 24.1 Total Output s ftlTon 498.8 1 49,311 41,686 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Exist. HVAC 45,779 5,336 890,000 Airflow (cfmis ft) 0.80 Airflow cfm]Ton 400.0 Outside Air (1° 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 45,779 5,336 890,000 Jan 1 AM Outside Air cfmis fF 0,00 Note: values above Len at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peaks 26 OF 69 OF 105 OF 105 OF Outside Air-4 M � i �H - r- 0 cfm Heating Coil Supply Fan 104 OF 2,000 cfm ROOM 69 OF Return Fan 69 OF 70 OF — L 1,400 cfm COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Conlin Peak 112/78OF 76/62°F 55/54°F 55/54°F O Outside Air 0 cfm Cooling Coil Supply Fan 56 / 54 OF 2,000 cfm — - 47.8 % ROOM Return Fan `J 76 / 62 OF 76 / 62 OF 75 � o lII4. 1,400 cfm HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name 'Dance Residence Addition pate 12/26/2018 System Name HVAC-Sleeping Floor Area 1,655 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,040 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 61,000 21,341 2,107 646 23.592 Total Output (Btuh) 61,000 0 Output Btuh/s ft 36.9 1,232 1,159 Cooling System 0 t Output per System 49,000 0 0 0 Total Output Btuh 49,000 0 1,732 23,805 2,107 Total Output Tons 4.1 1,159 Total Output Btuh/s ft 29.6 Total Output s ft/Ton 405.3 25,910 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 24ANB748-58CVX080 36.955 4,602 61,000 Airflow cfm/s ft 0.97 Airflow cfm/Ton 391.8 Outside Air (%) 0.0 % Total Adjusted System Output 36,955 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 4,602 Aug 3 PM 61,000 Jan 1 AM Outside Air (cfm/s ft) 0.00 1Note: values above given at ARI conditions 'HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 69 OF 69 OF 105 OF 105 OF Heating Coil Supply Fan 1,600 cfm 104 OF ROOM Imo_. 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak) 112/78OF Outside Air 0 cfm 76/62OF 76/62OF 55/54OF 55/54OF Cooling Coil Supply Fan 56 / 54 OF 1,600 cfm 47.6% ROOM 75/62OF y HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Vance Residence Addition Date 12/26/2018 System Name HVAC-Casita Floor Area 308 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 229 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 51.000 4,773 392 141 5,200 Total Output Btuh 51,000 0 Output Btuh/s ft 165.6 2761 256 Cooling System C)l n Output per System 18,000 0 0 0 0 Total Output Btuh 18,000 01 j 392 0 Total Output (Tons) 1.5 276 256 Total Output (Btuh/s ft) 58.4 Total Output s ft/Ton 205.3 5,324 , 5,711 Air System CFM per System 600 HVAC EQUIPMENT SELECTION Airflow cfm 600 copy of Carrier 24ANB718/58CVX070 j 13,556 1,632 51,000 Airflow cfm/s ft 1.95 Airflow cfm/Ton 400.0 Outside Air (%) 0.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 13,556 1.632 51,000 Jan 1 AM Outside Air cfmfs ft 0.00 Note: values above given at ARI conditions Aug 3 7 HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 70 OF 70 OF 105 OF 105 OF 0 U I Heating Coil Supply Fan 600 cfm n I I fl 105 OF ROOM 70 OF _ j COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air 0 cfm 75 / 62 °F 75/62OF 55/54OF 55/54OF Cooling Coil Supply Fan 600 cfm 4 AT-1 I U 55 / 54 OF 46.8 % ROOM -� 75 / 62 °F ZONE LOAD SUMMARY Project Name Vance Residence Addition Date 1212612018 System Name HVAC-Living Floor Area 2,494 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible Living Zone 1.0 0 Aug 3 PM 2,191 43,389 3,175 1,033 37,374 TOTALS 0 0 0 0 Aug 3 PM 43,389 3,175 37,374 (BLOCK LOAD] ZONE LOAD SUMMARY Project Name Vance Residence Addition Date 1212612018 System Name HVAC-Sleeping Floor Area 1,655 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible Sleeping Zone 1.0 0 Aug 3 PM 975 20,004 1,888 579 21,157 Closet Addition 1.0 0 Aug 3 PM 65 1,337 219 67 Z435 I TOTALS 01 0 0 0 Aug 3 PM 21,341 2,1071 23,592 (BLOCK LOAD) ZONE LOAD SUMMARY Project Name Date Vance Residence Addition 1212612018 System Name Floor Area HVAC-Casita 308 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible New Casita Zone 1.0 0 Aug 3 PM 229 4,773 392 141 5,200 I TOTALS 0 0 0 0 Aug 3 PM 4, 773 3921 5,200 (BLOCK LOAD)