Loading...
BELC2018-012878-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: ELECTRICAL/ BELC2018-0128 78136 FRANCIS HACK LN `e-d4t 4 4oQw;,rw DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT 770184007 SPRINT / (6) ANTENNA CHANGE OUT $15,000.00 Applicant: SPRINT-1USTIN DAVIS 200 SPECTRUM CENTER SUITE 1700 IRVINE, CA 92618 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 1/29/2019 Owner: Global Signal Acquisitions Iv P.O. BOX 277455 ATLANTA, GA 30384 Dontractor: HE W CORPORATION DBA VANTAGE COMPANY JAN 2 9 2019 643 WEST ORANGEGROVE AVE RANGE, CA 92868 O8 CITY OF LA QUINTA DESIGN & DEVELOPMENT DEPARTMEO114)532-8800 Llc. No.: 799597 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B. A. C10 License No: I �,� F ' � � f Cantracto�: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its Issuance, also requires the applicant for the permit to file a signed statement that he orshe is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applfcant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (--_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale, (Sec. 7044, Business and Professions Cade: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale.. If, however, the building or improvement is sold within one year of completion, the owner-bui€der will have the burden of proving that he or she did not build or improve for the purpose of sale.). (—) I, as owner of the property, am exclusively contracting with Iicensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' com ,m tion, as provided far by Section 3700 of the Labor Code, for the performance of a work for which this permlt is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 or the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier:.ORPQRAILON Policy Number: Al CW13721 800 _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith complywiththose provisions. Pat • i G Applicant: Rem WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La QuInta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation, I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above - mentioned property for inspection purposes. : } " v I l I \ .4NNNIII (Applicant or Agent): D61e:' " 1/29/2019 Application Number: BELC2018-0128 Property Address: 78136 FRANCIS HACK LN APN: 770184007 Application Description: SPRINT / (6) ANTENNA CHANGE OUT Property Zoning: Application Valuation: $15,000.00 Applicant: SPRINT - JUSTIN DAVIS 200 SPECTRUM CENTER SUITE 1700 IRVINE, CA 92618 Owner: Global Signal Acquisitions Iv P.O. BOX 277455 ATLANTA, GA 30384 Contractor: THEW CORPORATION DBA VANTAGE COMPANY 1643 WEST ORANGEGROVE AVE ORANGE, CA 92868 (714)532-8800 Llc. No.: 799597 Detail: REPLACEMENT OF SPRINT COMMUNICATIONS EQUIPMENT - REMOVE AND REPLACE (6) ANTENNAS, INSTALL (6) RRH'S, AND INSTALL NEW TOP HAT ON EXISTING EQUIPMENT CABINET. 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNT CITY AMOUNT HOURLY CHARGE - ESGIL CIVIL ENGINEER 101-0000-42600 2 $210.00 Total Paid for BLDG CITY STAFF - PER HOUR: $210.00 DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT Credit Card Fee 101-0000-43505 0 $6.85 Total Paid for Credit Card Fee: $6.85 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $26.68 Total Paid for ELECTRICAL: $53.36 DESCRIPTION ACCOUNT CITY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $101.40 Total Paid for PERMIT ISSUANCE: $101.40 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 CCCROWN CASTLE MEMO TO: Sprint PCS Kerri Shimer Sprint DO Macro Upgrade RTI Memo FROM: Justin Davis/ (949) 885-9879 /Justin.Davis@crowncastle.com DATE: January 11, 2019 SITE: RV54XC488 / 879934 78136 Francis Hack Lane La Quinta, CA 92253 Building; Pc:rniit Ready to Issue Crown Order Number: 408201 Equipment Configuration: Sprint proposes to remove (3) antennas, remove (3) combiners, remove (1) .5/8" hybrid line; & add (3) antennas, add (6) 800 RRU, add (1) 1-1/4" hybrid line Crown Castle has confirmed with the jurisdiction that the building permit application for the Scope of Work at the site referenced above has been reviewed and approved. The building permit is ready to be issued as of January 11, 2019, pending the following information: Jurisdiction Reauirements: RTI - GC needs to pick up Fees need to be paid at time of pick up; total owed is $380.76 Awarded Contactor information: N/A Jurisdiction Contact Information: Jurisdiction: CITY OF LA QUINTA, CA / Building Department Address: 78495 Calle Tampico La Quinta, CA 92253 Contact Name: Phone: (760) 777-7084 Permit Reference #: BELC2018-0128 Permitting Services Scope of Work. This Memo will service as notification and confirmation that Crown Castle has satisfied the terms of its agreement to provide Permitting Services, and the Awarded Contractor listed above is responsible for obtaining the building permit from the jurisdiction. It is recommended that the General Contractor contact the jurisdiction prior to their attempt to pick up the Building Permit and verify if any additional information is required to acquire the Permit beyond what is listed above. Area Real Estate -- Final Checklist -- (v.7*) BU # 879934 Customer Sprint Job# Real Estate Specialist 462409 App# 408201 Justin Davis jurisdiction (yDX) City of La Qu.inta Zorting Required Yes BP Required Yes Packages *Highlight what is applicable ZAP Package ZOK Package BAP Package BOK Package Application 6409 Letter Copy of Check Receipt from Planning Photosim RF Calculations EME Study Miscellaneous No Zone Letter Planning Approval Stamped Plans COA Letter Application Copy of Check Receipt from Bp Fire Approval w/ Check Copy No BP Letter I BP Approval I BP RTI I Closeout Mark "X" If No Zoning Fees Mark "X" If No BP Fees X :Summary of Real Estate Reimbursables :Zoning Payments Sub date Check # Amount Permit Date Application/Plan Review 12/7/2018 20744 $272.00 12/7/2018 Other Fees if/as required* BP Payments Sub Date Check # Amount Permit Date Application/Plan Review 1/0/1900 Other BP Fees if/as required* 1/0/1900 'TOTAL Real Estate Fees Paid (sum all) $272.00 Contract Limit on Reimbursables (subtract) $0.00 'TOTAL BILLABLE FEES $272.00 Preparer's Name: Lorena Soriano Date Completed 1/11/2019 Code 6220.37620 tevQaigra e GEM ed DESERTT - PERMIT# PLAN LOCATION: Project Address: 78136 Francis Hack Lane Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: 770-184-007 Remove and replace (6) antennas. Install (6) RRH's. Install top hat on to existing equipment cabinet. Applicant Name: Sprint - Justin Davis Address: 200 Spectrum Center Suite 1700 City, ST, Zip: Irvine, CA 92618 Telephone: 949-885-9879 Email: Justin�DaviQll (Ow r M Valuation of Project $ 15,000 Contractor Name: TBD New SFD Construction: Address: Conditioned Space SF City, St, Zip Garage SF Telephone: Patio/Porch SF Email: Fire Sprinklers SF State Lie: City Bus Lie: Arch/Eng Name: JRA Construction Type: Occupancy: Address: 131 Innovation Grading: City, St, Zip Irvine, CA 92617 Telephone: 949-760-3923 Bedrooms: Stories: # Units: Email: State Lie: C20876 City Bus Lie: Property Owner's Name: Global Signal Acquisitions IV LLC New Commercial / Tenant Improvements: Address: PO BOX 277455 Total Building SF City, ST, Zip Atlanta, GA 30384 Construction Type: Occupancy: Telephone: 941-308-5986 Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 • A ` " OFFICE USE ONLY # Submittal Req'd Rec'd Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License EsGilpany DATE: 1/3/2019 ❑ APPLICANT �JURIS. JURISDICTION: City of La Quinta PLAN CHECK #.: BELC2018-0128 SET: I PROJECT ADDRESS: 78136 Francis Hack Lane PROJECT NAME: Sprint Fire Station #32 RV54XC488 Crown Site : 879934 ® The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ❑ The applicant's copy of the check list has been sent to- ® EsGil staff did not advise the applicant that the plan check has been completed. ❑ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: bb ) Email: Maid Telephone Fax In Person REMARKS: structural review only. By: David Yao Enclosures: EsGil 12/21/18 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Date: October 03, 2018 Cathy Garziano Crown Castle 2055 S. Stearman Drive Chandler, AZ 85286 Subject: Carrier Designation: Crown Castle Designation GITY OF LA UUIIV I A 13UILDING DIVISION REVIEWED FOR CODE C MPLIANCE nATr- 114 uNRY Engineering Firm Designation: Site Data: Dear Cathy Garziano, Structural Analysis Report Sprint PCS Co -Locate Carrier Site Number: Carrier Site Name: C L S a �c�amon � �an�J�aiati CLS Group 319 Chapanoke Road, Suite 118 Raleigh, NC 27603 (405) 348-5460 Crown Castle BIJ Number: Crown Castle Site Name: Crown Castle JDE Job Number: Crown Castle Work Order Number: Crown Castle Order Number: CLS Group Project Number: RV54XC488 N/A 879934 FIRE STATION #32 462409 1640887 408201 Rev. 5 42285-CCI STR-879934-1640887 78136 Francis Hack Lane, La Quinta, Riverside County, CA Latitude 33° 40' 16.81 ", Longitude -116' 18' 5.04" 65 Foot - Monopole Tower CLS Group is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above mentioned tower. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC5: Proposed Equipment Configuration Sufficient Capacity The analysis has been performed in accordance with the TIA-222-H Standard. This analysis utilizes an ultimate 3-second gust wind speed of 110 mph as required by the 2016 California Building Code. Exposure Category C and Risk Category II were used in this analysis. Structural analysis prepared by: e Pat l� E.I. _ Respectfully submitted by: ' _ • , DEC 2 0 2018 Tyler M. Barker, P.E. Director of Engineering CITY OF LA QUINTA COMMUNITY DEVELOPMENT 1"� cuc, Z,6 19-- 0 12-- & tnxTower Report - version 8.0.4.0 C 80327 LM& �� CA4Ir gitally signed Ty'""by Tyler M. Group coup Dimtor of E*nwrUy Barker PE 0 C40327 Up. 9/30/2020 Date: 2018.10.04 18:13:25-04'00' October 03, 2018 65 Ft Monopole Tower Structural Analyses CC/ BU No 879934 Project Number 42285-CCI STR-879934-1640887, Order 408201, Revision 5 Page 2 TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Equipment Configuration Table 2 - Other Considered Equipment 3) ANALYSIS PROCEDURE Table 3 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 4 - Section Capacity (Summary) Table 5 — Tower Component Stresses vs. Capacity 4.1) Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations tnxTower Report - version 8.0.4.0 October 03, 2018 65 Ft Monopole Tower Structural Analysis CCI BU No 879934 Project Number 42285-CCI STR-879934-1640887, Order 408201, Revision 5 Page 3 1) INTRODUCTION This tower is a 65 ft Monopole tower designed by Aerial in November of 2001. The existing monopole has four major sections connected by slip joints. It has 18 sides and is evenly tapered from 24.75" (flat -flat) at the base to 14.0" (flat -flat) at the top. The structure is disguised in faux bark and has no aviation lighting. 2) ANALYSIS CRITERIA Building Code: TIA-222 Revision: Risk Category: Wind Speed: Exposure Category: Topographic Factor: Ice Thickness: Wind Speed with Ice: Seismic Ss: Seismic S1: Service Wind Speed: 2016 California Building Code TIA-222-H 11 110 mph C 1 0 in 30 mph 1.50 0.61 60 mph Table 1 - Proposed Equipment Configuration Center Number Number Feed Mounting Line of Antenna Antenna Model of Feed Line Level (ft) Elevation Antennas Manufacturer Lines Size (in) (ft) 6 alcatel lucent 1900MHz RRH (65MHz) 6 alcatel lucent 80OMHZ RRH 3 alcatel lucent TD-RRH8x20-25 65.0 65.0 3 cci antennas TPA65R-KE6D w/ Mount 4 1-1/4 Pipe 3 rfs celwave APXVTM14-ALU-120 w/ Mount Pipe 1 tower mounts T-Arm Mount [TA 702-31 Table 2 — Other Considered Equipment Center Mounting Line Number Antenna Number Feed Level (ft) Elevation of Manufacturer Antenna Model of Feed Line (ft) Antennas Lines Size (in) 1 andrew VHLPX1-18 _ 60.0 60.0 2 3/8 tower mounts Pipe Mount [PM 601-1] 1 HBX-3319DS-VTM w/ 6 andrew Mount Pipe 56.0 56.0 12 7/8 1 tower mounts Side Arm Mount [SO 102- 3] tnxTower Report - version 8 0.4.0 October 03, 2018 65 Ft Monopole Tower Structural Analysis CC/ BU No 879934 Project Number 42285-CCI STR-879934-1640887, Order 408201, Revision 5 Page 4 3) ANALYSIS PROCEDURE Table 3 - Documents Provided Document I Remarks { Reference I Source 4-GEOTECHNICAL REPORTS ATC 1577428 CCISITES 4-TOWER FOUNDATION Aerial/PJF ��� 2056740 CCISITES DRAWINGS/DESIGN/SPECS —� 4-TOWER MANUFACTURER Aerial/PJF 2056739 CCISITES DRAWINGS 3.1) Analysis Method tnxTower (version 8.0.4.0), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions 1) Tower and structures were built and maintained in accordance with the manufacturer's specifications. 2) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. This analysis may be affected if any assumptions are not valid or have been made in error. CLS Group should be notified to determine the effect on the structural integrity of the tower. 4) ANALYSIS RESULTS Tahlp 4 - Section Canarity 11Summarv1 Section No. Elevation (ft) Component Type Size Critical Element P (K) 5F*P_allow (K) % Capacity pass /Fail L1 I 65 - 49.75 Pole TP16.639xl4x0 25 1 -3.324 990.389 24.8 Pass L2 49.75 - 0 Pole TP24.75xl5.75x0.25 2 -7.809 1505.395 65.8 Pass Summary Pole (1-2) 65.8 Pass r� Rating = 65.8 Pass Tahlp 5 - Tnwpr Cmmnonent Stresses vs. Canacitv — LC5 Notes Component Elevation (ft) %Capacity Pass /Fail 1 Anchor Rods 0 73.5 Pass 1 Base Plate 0 57.3 Pass 1 Base Foundation 0 28.9 Pass 1 Base Foundation f 0 Soil Interaction 37.3 Pass Structure Rating (max from all components) = 73.5% Notes: 1) See additional documentation in "Appendix C — Additional Calculations" for calculations supporting the % capacity consumed. tnxTower Report - version 8.0,4.0 October 03, 2018 65 Ft Monopole Tower Structural Analysis CCI BU No 879934 Project Number 42285-CCI STR-879934-1640887, Order 408201, Revision 5 Page 5 4.1) Recommendations The tower and its foundation have sufficient capacity to carry the proposed load configuration. No modifications are required at this time. tnxTower Report - version 8.0.4.0 CLS GROUP SUPPLEMENTARY ASSUMPTIONS AND CONDITIONS This analysis considers only the theoretical capacity of structural components and it is not a condition assessment of the tower or foundation. The validity of the analysis is dependent on the accuracy of structural information supplied by others. The tower owner is responsible for verifying this information. If any provided information is revised after completion of this analysis, CLS Group should be notified immediately to revise results. This analysis assumes the following 1) The tower and foundation (if applicable) were properly constructed as per the original design and have been properly maintained in accordance with applicable code standards unless field information shows otherwise. 2) All prior structural modifications, if any, are assumed to be correctly installed and fully effective unless field information shows otherwise. 3) All mounts are assumed adequate to support their antenna loading. No structural verification of the mounts has been performed. This analysis is limited to analyzing only the tower its foundation (if applicable). 4) Some conservative assumptions are made regarding appurtenances and their projected areas based on careful interpretation of data supplied, previous experience and standard industry practice. All opinions and conclusions are considered accurate to a reasonable degree of engineering certainty based upon the evidence available at the time of the report and are subject to revision based upon receipt of new or updated information. All services are provided exercising a level of care and diligence equivalent to the standard of our profession. No warranty or guarantee, either expressed or implied, is offered. All services are confidential in nature and this report will not be released to any other party without the client's consent. All services were performed, results obtained and recommendations made in accordance with generally accepted engineering principles and practices. CLS Group is not responsible for the conclusions, opinions or recommendations made by others based on the information supplied in this analysis. October 03, 2018 65 Ft Monopole Tower Structural Analysis CC/ BU No 879934 Project Number 42285-CCI STR-879934-1640887, Order 408201, Revision 5 Page 6 APPENDIX A TNXTOWER OUTPUT tnxTower Report - version 8.0.4.0