BMCH2019-0023DflL1CRJ VOICE (760) 777-7125
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 1/16/2019
Permit Type/Subtype: MECHANICAL/ Owner:
Application Number: BMCH2O19-0023 STITZ DAVID D & CLAUDIA E
Property Address: 50590 NECTAREO ST ST 50590 NECTAREO
APN: 776280024 LA QUINTA, CA 92253
Application Description: STITZ/ (3)HVAC CHANGEOUTS-18 ANDI4SEER/80AFUE SPLIT SYSTEMS
Property Zoning:
Application Valuation: $18,914.00
Applicant: z�, Contractor:
IE INC. l� TIMO'S AIR CONDITIONING & HEATING INC
32115 LA BAYA 72232 CORPORATE WAY
WESTLAKE VILLAGE, CA 91362 JAN 16 2019 THOUSAND PALMS, CA 92276
CITY OF LA QUINTA (760)770-4357
DESIGN & DEVELOPMENT DEPARTMENT Llc. No.: 920062
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: License No.: 42t70&Z
■
Date: I ) 9 Contractor:.
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031,5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.),
(_) I am exempt under Sec. B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Ad
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
ofarkfor which this permit is issued.
'M, I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: N RGUARD INSURANCE COMPANY Policy Number: TIWC985097
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date:' Illb Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above -mentioned property For inspection purposes.
Date: llll� I Signature(ApplicantorAgent):�—
Date: 1/16/2019
Application Number:
BMCH2O19-0023
Owner:
Property Address:
50590 NECTAREO ST ST
STITZ DAVID D & CLAUDIA E
APN:
776280024
50590 NECTAREO
Application Description:
STITZ/ (3)HVAC CHANGEOUTS-18 ANDI4SEER/80AFUE SPLIT SYSTEMS
LA QUINTA, CA 92253
Property Zoning:
Application Valuation:
$18,914.00
Applicant:
Contractor:
IE INC.
TIMO'S AIR CONDITIONING & HEATING INC
32115 LA BAYA
72232 CORPORATE WAY
WESTLAKE VILLAGE, CA 91362
THOUSAND PALMS, CA 92276
(760)770-4357
Llc. No.: 920062
Detail: (1) MINI -SPLIT SYSTEM CHANGE OUT 18SEER/80AFUE. (2) HVAC CHANGE OUTS - (2) -TON, AND (3) -TON 14 SEER/80 AFUE SPLIT SYSTEMS. CARBON
MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. PER 2016 CALIFORNIA BUILDING CODES.
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT QTY AMOUNT
BSAS SB1473 FEE
101-0000-20306 0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM
101-0000-42402
0
$120.06
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM PC
101-0000-42600
0
$240.15
Total Paid for CHANGEOUT: $360.21
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PERMIT ISSUANCE
101-0000-42404
0
$101.40
Total Paid for PERMIT ISSUANCE: $101.40
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
tev
— GEM nfde DESERT —
PERMIT # A4 c- H ZO l ct ^ O�j Z2j
PLAN LOCATION:
Project Address: 50590 Nectareo
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #:
Replace 1.5 ton ductless mini split system in back yard
Replace 3 ton / 60,000 BTU complete HVAC system
Applicant Name: Steven Schnierer
Replace 2 ton / 40,000 BTU complete HVAC system
Address: 31225 La Baya Drive Suite 213
City, ST, Zip: Westlake Village, CA 91362
Telephone: 818-735-7876
Email: swschnierer@roadrunner.com
Valuation of Project s 18,914.00
Contractor Name: Timo's A/C $ Heating
Address: 72232 Corporate Way
New SFD Construction:
Conditioned Space
SF
City, St, Zip Thousand Palms, CA 92276
Garage
SF
Telephone: 760-770-4357
Patio/Porch
SF
Email:
Fire Sprinklers
SF
State Lic: 920062 City Bus Lic:
Arch/Eng Name:
Construction Type: Occupancy:
Address:
Grading:
City, St, Zip
Telephone:
Bedrooms: Stories:
# Units:
Email:
State Lic: City Bus Lic:
Property Owner's Name: David Stitz
New Commercial / Tenant Improvements:
Address: 50590 Nectareo
Total Building SF
City, ST, Zip La Quinta, CA 92253
Construction Type: Occupancy:
Telephone: 760-564-8410
Email:
78495 CALLE TAMPICO
LA QU I NTA, CA 92253
760-777-7000
OFFICE USE ONLY
#
Submittal
Req'd
Ree'd
Plan Sets
Structural Calcs
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
Jack Lima
From: Steven Schnierer <swschnierer@roadrunner.com>
Sent: Wednesday, January 16, 2019 11:33 AM
To: Jack Lima
Subject: RE: Permit Request 3 of 4 - HVAC Replacement At 50590 Nectareo
Per Timo's, the mini split is on the back side of the casita towards the left side property line and it is serving the casita
only. There is currently a mini split system there that they are changing out.
-------- Original message --------
From: Jack Lima <jlima@laquintaca.gov>
Date: 1/16/19 11:12 AM (GMT-08:00)
To: Steven Schnierer <swschnierer@roadrunner.com>
Subject: RE: Permit Request 3 of 4 - HVAC Replacement At 50590 Nectareo
Sounds good.
Please be sure to depict the equipment location and dimensions from the setbacks. This appears to be a new
unit because we could not find an initial permit for a mini -split system.
Chat with you soon,
Jdck Limci I Permit Technician
City of La Quinta
78495 Calle Tampico , La Quinta, CA 92253
760.777.7195
From: Steven Schnierer
ilima@aLquintaca.gov
<swschnierer@road run ner.com>
Sent: Wednesday, January 16, 2019 10:54 AM
To: Jack Lima <jlima@laquintaca.gov>
Subject: RE: Permit Request 3 of 4 - HVAC Replacement At 50590 Nectareo
I'll have to draw something when I get there. The order says it is in the back yard. In the far back corner of the property
there is an area that has what looks like the pool equipment. Not sure if that is where it is located. Waiting to hear back
from Timo's for the precise location.
Original message
From: Jack Lima <0lima lag uintaca. ov>
Date: 1/16/19 9:38 AM (GMT-08:00)
To: Steven Schnierer <swschnierer , roadrunner.Com>
Subject: RE: Permit Request 3 of 4 - HVAC Replacement At 50590 Nectareo
Hi Steven,
For this changeout we need a site plan depicting the location of the mini -split system before we can issue the
permit. Please let me know if you have any questions.
Respectfully,
Jack Lima I Permit Technician
City of La Quinta
78495 Calle Tampico o La Quinta, CA 92253
760.777.7195
it i ma@ laqui ntaca-Rov
<5wschnierer2roadrunner.com>
Sent: Wednesday, January 16, 2019 6:34 AM
From: Steven Schnierer
To: Aaron Hickson <ahickson@Iaguintaca.goV>; Armando Magallon <am aga lion@ laauintaca,gov>; Jack Lima
<"lima la uintaca. ov>; Stephanie Swanstrom <5swanstromelaguintaca.gov>
Subject: Permit Request 3 of 4 - HVAC Replacement At 50590 Nectareo
Steven Schnierer
I Permit E Raters
31225 La Baya Drive Suite 213
Westlake Village, CA 91362
Office: (818) 735-7876
Fax: (818) 735-3575
Cell: (951) 334-9978
Email: swschnierer@roadrunner.com
Website: www.ipermiteraters.com
NOTICE: This email message and any attachments hereto may contain confidential information. Any unauthorized
review, use, disclosure, or distribution of such information is prohibited. If you are not the intended recipient, please
contact the sender by reply email and destroy the original message and all copies of it.
NOTICE: This email message and any attachments hereto may contain confidential information. Any unauthorized
review, use, disclosure, or distribution of such information is prohibited. If you are not the intended recipient, please
contact the sender by reply email and destroy the original message and all copies of it.
3
CERTIFICATE OF COMPLIANCE
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC)
CF1R-ALT 02-E
(Page 2 of 4)
C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib)
This section does not apply to this project.
D. Altered Space Conditioning System (Sections 150.2(b)lE and F)
01 02 03 04 05 06 07 08 09 10
11 12
Heating Cooling
System Heating Altered Heating Minimum Altered Cooling Minimum Required
New or
Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat
Replaced New Duct
or Name Type Components Type Value System Type Components Type Value Type
Duct Length R-Value
Central as All new All new
System 2 g heating AFUE 0 g CentACl split cooling SEER 14 Setback
furnace
This field or This field or
section is not section is not
components components
applicable applicable
Central as All new All new
System 3 g heating AFUE 0 g CentACl split cooling SEER 14 Setback
furnace
This field or This field or
section is not section is not
components components
applicable applicable
Required Documentation:
CF211-MCH-01-E - Space Conditioning Systems
- Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16)
CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced
-Leakage rate compliance: <= 15 percent or <=10 percent leakage to outside, or seal all accessible leaks.
CF211 and CF311-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH-25 is required.
Exceptions:
Duct systems registered with HERS provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements.
Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MCH-25.
-Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements.
E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)lE, F)
This section does not apply to this project.
Registration Number: 419-A020004574A-000-000-0000000-0000
Registration Date/Time: 2019-01-15 12:30:31
HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-01-15 12:30:30
Srhama Varcinn: rav 2MRn4Jf
CF111-ALT-02-E
CERTIFICATE OF COMPLIANCE
(Page 3 of 4)
Alterations to Space Conditioning Systems (formerly CF-IR-ALT HVAC)
1
Complete Re n 150.2(b)1C)
F. Entirely New or Comp Replacement Space Conditioning System (Sectio
p
02 03 04
05
06
07
08
09
10 11
01
Cooling
Heating
Cooling
Minimum
Required
Heating
System
Altered Heating Efficiency
Minimum
Efficiency
Cooling
Altered Cooling
Efficiency
Efficiency
Thermostatew Duct
tat NR-Value
Identification or Heating System
Component Type
Value
System Type
Component
Type
Name Type
This field
Annual Fuel
Ductless
Ductless
All new cooling
18
SetbackTher or section
All new heating Utilization
System 1 Multi -Split Heat components Efficiency
0 8
Multi -Split
Heat Pump
components
SEER
mostat is not
applicable
Pump (AFUE)
Required Documentation:
CF2R-MCH-01-E - Space Conditioning Systems
- Duct insulation requirement for the new portions of supply air and return air ducts or plenums: R6 (CZ 1-50, 12 and 13) and R8 (CZ 11 and 14-16)
CF2R and CF3R-MCH-20-H Duct Leakage Test required
- Leakage rate compliance: <= 5%.
CF2R and CF311-MCH-22 Fan Efficacy
CF2R and CF3R-MCH-23 Airflow Rate Verification
Compliance: Fan Efficacy <= 0.58 W per cfm and System Airflow >= 350 cfm per ton.
Alternative Compliance: CF2R and CF3R-MCH-28 Return Duct Design verification is an alternative to MCH-22 and MCH-23 .,Lr itication.
CF2R and MR-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
Exceptions:
Heating -only systems are exempt from the 0.58 W per cfm and 350 cfm per ton requirements. y registers,
Ne: An "entirely new or replacement duct system" means at least 75% of the dud system is new duct material, and up to 25% may consist of reused parts from the dwellingunit's existing ducts stem (e.g., g
grilles, boots, air handler, coil, plenums, duct material) if the reused parts are accessible and can be sealed to prevent leakage
Registration Number: 419-A020004574A-000-000-0000000-0000
Registration Date/Time: 2019-01-15 12:30:31
HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Report Version: 2018.0.001
Srhpma Vprcinn: rpv 7n1 R0476
Report Generated: 2019-01-15 12:30:30
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-1R-ALT HVAC) (Page 4 of 4)
Documentation Author's Declaration Statement
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Drew Queen
'Drm Quze*v
Company:
Signature Date:
I Permit E Raters
2019-01-15
Address:
CEA/ HERS Certification Identification (if applicable):
31225 La Baya Drive
City/State/Zip:
Phone:
Westlake Village CA 91362
818-735-7876
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Responsible Designer Signature:
Joey Timo
J6?,y rLff�
Company:
Date Signed:
Timo's Air Conditioning & Heating
2019-01-15
Address:
License:
72232 Corporate Way
City/State/Zip:
Phone:
Thousand Palms CA 92276
760-770-4357
Digitally signed by CHEERS"". This digital signature is provided in order to secure the content of this registered
document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 419-A020004574A-000-000-0000000-0000 Registration Date/Time: 2019-01-15 12:30:31 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-01-15 12:30:30
Srhpma Vpminn- rpv 2n1Rn42f,
CF1R-ALT-02-E
CERTIFICATE OF COMPLIANCE
(Page i of 4)
Alterations to Space Conditioning Systems (formerly CF-1R-ALT HVAC)
Davi�Stitz [DatePrepared: 2019-01-15
Project Name: :��
A. General Information
ained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF1R-ALT-02 is applicable to multiple space conditioning systems cont
CF1R-ALT-02 document for each dwelling unit.
01
Project Name
02
Date Prepared
2019-01-15
Project Location
Nectareo
04
Building Type
Single family
03
qDaStitz
CA Citynta
Zip Code
06
08
Dwelling Unit NameDavid
Dwelling Unit Conditioned
Floor Area (ftz)
Stitz
2577
05
07
Number of Space
09
Climate Zone
15
10
Conditioning (SC) Systems in
this Dwelling Unit:
3
B. Space Conditioning (SC) System Information
01
02
03
04
Is the SC
SC System
SC System
CFA served
system a
Identification or
Location or Area
by this SC
ducted
Name
Served
System (ftz)
system?
System 1
System 2
System 3
05
06
07
08 09
Installing a
refrigerant
Installing new SC
Installing
Installing Installing
containing
system
more than 40
entirely new entirely new
component?
components?
feet of ducts?
duct system? SC system?
Location 1
859
No
No
Yes
No
No Yes
Location 2
859
Yes
Yes
Yes
No
No No
Location 3
859
Yes
Yes
Yes
No
No No
10
Alteration Type
Entirely new or
complete
replacement space
conditioning system
Altered space
conditioning system
Altered space
conditioning system
g
Re istration Date/Time: 2019-01-15 12:30:31
HERS Provider: CHEERS
Registration Number:419-A020004574A-000-000-0000000-0000
Report Version: 2018.0.001 Report Generated: 2019-01-15 12:30:30
CA Building Energy Efficiency Standards 2016 Residential Compliance Srhama Varcinn: rPv 7nl Rn496
i.j AOVI
M l'y.l Spki Systeri
r Cc�si�ic. �
-wolw-z
Is
SDSCIO `V eG�0.rep
Lc- &u;ria , c [--,
PL
Po I
N ec 6,k,�p
2