Loading...
BRES2017-031478-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: SUNROSE CORPORATION 72-850 SOMERA ROAD PALM DESERT, CA 92260 T4,tivl 4 41 Qa4a DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED BRES2017-0314 53747 VIA STRADA 777200009 TOWNSEND / 8,410SF DWELLING/VB/RES-3/CLASS A-FR/13D VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 1/16/2019 Owner: MICHAEL TOWNSEND / AMBER TOWNSEND 53747 VIA STRADA LA QUINTA, CA 92253 $729,065.00 D Contractor: MARIO A YANEZ CONSTRUCTION JAN 16 2019 PO BOX 580925 DD NORTH PALM SPRINGS, CA 92258 CITY OF LA QUINTA DESIGN &DEVELOPMENT DEPARTMENT (760)285-1532Llc. No.: 1026884 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section_7000j of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: Br7 License No.: 1026884 Date:. �T�F Contractor: OWNER -BUILDER DEGLARA I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: () 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). () I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's WORKER'S COMPENSATION DECLARATION I here nder penalty of perjury one of the following declarations: will maintain a certificate of consent to self -insure for workers' c7elh-ave vided for by Section 3700 of the Labor Code, for the performance othis permit is issued. will maintain workers' compensation insurance, as required by abor Code, for the performance of the work for which this permit is ' compensation insurance carrier and policy number are: CaN C E COMPANY Policy Number: MAWC990876 at in the performance of the work for which this permit is issued, I shperson in any manner so as to become subject I the workers' Coe California, and agree that, if I should 0 subje e workers' compensation provisions of Section 3700 oft Cod , sh rthwith comply with those ��prrovisions. Dater 'W05r Applicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION OVERAGE IS NLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIESES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to b Id, construction, and hereby authorize representatives of this city to ente01 above -mentioned property for inspection purposes. DateyMnature (Applicant orAge Date: 1/16/2019 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: SUNROSE CORPORATION 72-850 SOMERA ROAD PALM DESERT, CA 92260 BRES2017-0314 53747 VIA STRADA 777200009 TOWNSEND / 8,410SF DWELLING/VB/RES-3/CLASS A-FR/13D $729,065.00 Owner: MICHAEL TOWNSEND / AMBER TOWNSEND 53747 VIA STRADA LA QUINTA, CA 92253 Contractor: MARIO A YANEZ CONSTRUCTION PO BOX 580925 NORTH PALM SPRINGS, CA 92258 (760)285-1532 Llc. No.: 1026884 Detail: 8,410SF 2-STORY SINGLE FAMILY DWELLING [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($104.55) DESCRIPTION ACCOUNT CITY AMOUNT PLAN CHECK/PERMIT EXTENSION PROCESSING 101-0000-42600 0 $104.55 Total Paid for ADMINISTRATIVE: $0.00 DESCRIPTION ACCOUNT CITY AMOUNT ART IN PUBLIC PLACES - RESIDENTIAL 270-0000-43201 0 $1,322.66 Total Paid for ART IN PUBLIC PLACES - AIPP: $1,322.66 DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($234.00) DESCRIPTION ACCOUNT CITY AMOUNT HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 1.5 $234.00 Total Paid for BLDG CITY STAFF - PER HOUR: $0.00 DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $30.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $30.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DESCRIPTION ACCOUNT I CITY I AMOUNT DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - LIBRARIES 253-0000-43200 0 $344.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARKS/REC 251-0000-43200 0 $2,048.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 DESCRIPTION ACCOUNT CITY AMOUNT TEMP POWER SERVICE 101-0000-42403 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT TEMP POWER SERVICE PC 101-0000-42600 0 $18.20 Total Paid for ELECTRICAL: $44.21 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EAADDITION 1,000SF 101-0000-42403 0 $119.34 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $49.14 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,OOOSF 101-0000-42403 0 $156.04 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $51.49 Total Paid for ELECTRICAL- NEW CONSTRUCTION: $376.01 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT>7KSF 101-0000-42408 0 $39.01 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT>7KSF PC 101-0000-42600 0 $195.05 Total Paid for GRADING: $234.06 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $234.06 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $156.06 DESCRIPTION ACCOUNT QTY AMOUNT EXHAUST HOOD 101-0000-42402 0 $13.00 DESCRIPTION ACCOUNT QTY AMOUNT EXHAUST HOOD PC 101-0000-42600 0 $5.20 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE 101-0000-42402 0 $234.06 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE PC 101-0000-42600 0 $156.06 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN 101-0000-42402 0 $221.00 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN PC 101-0000-42600 0 $88.40 Total Paid for MECHANICAL: $1,107.84 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PERMIT 101-0000-42400 0 $949.02 Total Paid for NEW CONSTRUCTION PERMIT: $949.02 DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($861.45) DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $861.45 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,146.05 Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,146.05 DESCRIPTION ACCOUNT QTY AMOUNT PLAN CHECK DEPOSIT- RESIDENTIAL 101-0000-42600 1 $1,200.00 Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $1,200.00 DESCRIPTION ACCOUNT QTY AMOUNT BACKFLOW DEVICE 101-0000-42401 0 $13.00 DESCRIPTION ACCOUNT CITY AMOUNT BACKFLOW DEVICE PC 101-0000-42600 0 $5.20 DESCRIPTION ACCOUNT CITY AMOUNT BUILDING SEWER 101-0000-42401 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT BUILDING SEWER PC 101-0000-42600 0 $18.20 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $429.00 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $429.00 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $39.01 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT ROOF DRAIN 101-0000-42401 0 $104.00 DESCRIPTION ACCOUNT CITY AMOUNT ROOF DRAIN PC 101-0000-42600 0 $104.00 DESCRIPTION ACCOUNT QTY AMOUNT SEWER CONNECTION/SEPTIC ABANDON 101-0000-42401 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT SEWER CONNECTION/SEPTIC ABANDON PC 101-0000-42600 0 $18.20 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $26.00 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $15.60 DESCRIPTION ACCOUNT CITY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $13.00 DESCRIPTION ACCOUNT CITY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $13.00 Total Paid for PLUMBING FEES: $1,305.24 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $20.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $20.00 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $94.78 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $94.78 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT I CITY I AMOUNT SINGLE FAMILY DETACHED I 224-0000-20320 I 0 $1,837.44 Total Paid for TUMF - RESIDENTIAL: $1,837.44 ---_ — — -�.�—_ 1ERMIT11 (2" PLAN LOCATION S-Fjj D Project Address: r Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech Applicant Name: Te%elnseneW Address: * /d 80,. 6 1 City, ST, Zip: �;. i r Telephone: 760 f 77 ` Email: �) r 6 Valuation of Project S U Contractor Name: �. New SFD Construction: Address: Conditioned Space 6gYQ SF City, St, Zip Garage (��n�� SF Telephone: Patio/Porch 6 ^/v SF Email: Fire Sprinklers SF State Lic: • City Bus Lic: Arch/Eng Name: 1 Construction Type: �� Occupancy; Address: 02�0 Grading: City, St, Zip�� jG� C ;zv (, .. - � Telephoner _�{r� it "L Bedrooms: 6 Stories: � # Units: Email: State Lic: City Bus Lic: Property Owner's Name: �l! New Commercial / Tenant Improvements: Address: Total Building SF City, ST, Zip Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 Project Name: M,ich.4?:3 Owner's Name: Michael Townsend Project Address: 53-747 Via Strada, La This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: I COMMAND. AMOUNT: DATE: RECEIPT: CHECK #: IMTIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) , CA 92253 Project Description: Single Family Dwelling Unit APN: 777-200-009 Tract #: Date: January 15, 2019 Phone No. Lot #'s: L11 Type of Development: Residential ? Commercial Industrial Total Square Feet of Building Area: 8,410 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement ECE1V-u ee to Fee 17620 65995 Approval Prior to 1/1�8 III���--- equirement Note: JAN RECI— 20"' Number of Sq.Ft. 8,410 Amount per Sq.Ft. $3.79 [x`fi'Y OF LA QUINTA Amount Collected $31,873.90 MMt4UNny E)EVELOPMENT Building Permit Application Completed: Yes/No By: Larry Moen, Director of Facilities _ Certificate issued by: Leticia Torres, Facilities Analyst Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90-day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90-day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. 11/2010 COACHELLA VALLEY UNIFIED SCHOOL DISTRICT 3 4 8 6 P.O. Box 847 • Thermal, California 92274 CC Phone: (760) 399-5137 DATE 20 n 9 RECEIVED FROM I 4. CU 71,r DOLLARS $ D FOR Amount of Account $ Amount Paid $ 9 D THANK Balance Due $ Cash ❑ Check/ M.0�C7 Form No_ 1793 1� By (/�� sAVE.e°asoiVT o} Payee: COACHELLA VALLEY UNIFIED SCHOOL DISTRICT Borrower: KADENWOOD DEVELOPMENT / TOWNSEND Builder: SUNROSE CORPORATION Property: LOT 257 - THE HIDEAWAY CC, RIVERSIDE, CA Invoice: CaCego:ry Code RECURRING COSTS B - 220 PERMITS AND FEES B - 207 462107595 82-504/1070 Amount 57.11 29,209.69 AUTHORIZED SIGNATURE 01/15/2019 $29,266.80 SUNROSE CORPORATION CONTRACTOR LIC. 533670 20728 Coachella Valley Unified School District Lot 257/ School fees 1/16/2019 2,607.10 Sunrose Corporation Lot 257 School fees 2,607.10 RECORDING REQUESTED BY: Title 305 AND WHEN RECORDED MAIL TO: Michael and Amber Townsend 80120 Via Palacio La Quinta, CA 92253 Order No.: CA510-16003194-51 Escrow No.: F51819 A.P.N.: 777-200-009.4 TRA: 020-160 DOC # 2016-0281130 07/07/2016 08:00 AM Fees: $24.00 Page 1 of 4 Recorded in Official Records County of Riverside Peter Aldana Assessor -County Clerk -Recorder "This document was electronically submitted to the County of Riverside for recording— Receipted by: CLAUDIA #061 SPACE ABOVE THIS LINE IS FOR RECORDER'S USE GRANT DEED THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX IS $ 1,127.50 [ X ] computed on full value of property conveyed, or [ ] computed on full value less value of liens or encumbrances remaining at time of sale. [ ] unincorporated area [ X ] City of La Quinta FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Robert A. Rovner and Irene G. Rovner, Trustees of The Rovner Family Trust U/D/T Date June 6,1988 hereby GRANT(S) to Michael Townsend and Amber Townsend, Husband and Wife as Joint Tenants the following described real property in the County of Riverside, State of California See Exhibit "A' attached hereto and made a part hereof. Commonly known as: 53747 Via Strada Lot 257 (Vacant Lot: APN: 777-200-009-4) , La Quinta, CA 92253 Dated: May 16, 2016 A notary public or other officer completing this certificate verifies only the identity of the individual who si Ad the document to which this certificate is attached nd not the truthfulness, accuracy, or validity of that do mant. STATE OF CALIFORNIA COUNTY OF On personally appeared before me, a notary public, who proved to me on the �dsis of satisfactory evidence to be the person(s) whose names) Ware subscribed to the within instrument and ac&nowl6dged to me that he/she/they executed the same in his/her/tlseir authorized capacity(ies), and that by his/her/their signatuce(s) on the instrument the person(s), or the entity upon behalf 6f which the person(s) acted, executed the instrument. r' I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. Signature The Rovner Family Trust U/DR Date June 6, 1988 lqt3 SS. By: abort Ro er,Irrustee By: Irene G. Rovner, Trustee R F C," F-1 V E D ad JAN 16 REC'D - 2oi 4 QTY OF LA QUINTA OOMMUNTTY DEVELOPMENT (Seal) (This area for official notary seal) MAIL TAX STATEMENTS AS DIRECTED ABOVE DOC #2016-0281130 Page 2 of 4 ACKNOWLEDGMENT A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. State Countyf California �)m � Coun of l On before me, Jennifer Simi, Notary Public (insert name and title of the officer) personally appeared 1 • Uf WX 1-7 V who proved to me on the basis of satisfactory evidence to be the personTs) whose name(s) Ware subscribed to the within instrument and acknowledged to me that hew"/they executed the same in hisAn-rltheir authorized capacity(ies), and that by hWhedtheir signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. JENN&ER SIMI } WITNESS my hand and official seal. . ; Commission # 2014378 t Notary Public - California z Contra Costa County '— M Comm. Ex ires Mar 24.2a17 Signature O ok l VY) (Seal) DOC #2016-0281130 Page 3 of 4 ksf4 LARRY W. WARD Recorder P.O. Box 751 COUNTY OF RIVERSIDE Riverside, CA 92502-0751 r z ASSESSOR -COUNTY CLERK -RECORDER (951)486-7000 NOTARY CLARITY Under the provisions of Government Code 27361.7, 1 certify under the penalty of perjury that the notary seal on the document to which this statement is attached reads as follows: Name of Notary: JENNIFER SIMI Commission #: 2014378 VIN #NNA1 Place of Execution: CONTRA COSTA Date Commission Expires: MAR 24, 2017 Date: July 7, 2016 Signature: ;-.1 Print Name: BH Estrada/TITLE365 ACR 186 (Rev. 09/2006) Available in Alternate Formats DOC #2016-0281130 Page 4 of 4 EXHIBIT A Legal Description The land hereinafter referred to is situated in the City of La Quinta, County of Riverside, State of CA, and is described as follows: Parcel 1: Lot 257 of amended Tract No. 29894-2, in the City of La Quinta, County of Riverside, State of California, as per Map recorded in Book 327, Pages 56 through 88, inclusive of Maps, in the Office of the County Recorder of said County. Except therefrom the oil, gas, minerals, and other hydrocarbon substances lying below the surface of said land, as provided in Deeds of Record. Parcel 2: Non-exclusive easements for access, ingress and egress, drainage, maintenance, repairs and for other purposes, all as described in the Declaration. APN: 777-200-009-4 Legal Description CA0510-16D03194-60124 Sunrose Corporation EM To whom it may concern: I Mike Tuvell of Sunrose Corporation would like to transfer the building permit from Sunrose Corporation to Mario Yanez Construction Inc. Sunrose Corporation Mike Tuvell, President RFC- EIVEur" ? ad, JAN 1'6 REC'D -zotq CrV OF LA QUINTA COMMUNITY DEVELOPMENT b14tF-S2i7-031V CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 9/25/2009 Green Sheet a rovals are forwarded to the Building & Safety,De artment directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date: 04 113 / 201 E Developer: Sunrose Corporation Tract No.:29894-2 Tract Name: Hideaway Address(s): 53-747 Via Strada La Quinta CA 92253 Lot No.(s):257 Phone Number: (760 ) 218-0566 The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the Building & Safety Department: ❖ CUSTOM HOMES: PROVIDE ITEMS #2 #3 #4 #5 & #7 BELOW TRACT HOMES: PROVIDE ITEMS #1. #2, #3 & #5 BELOW ❖ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1 #2 #3 #5 & #7 BELOW ❖ WALLS SIGNS OTHER: PROVIDE ITEM #6 BELOW 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation Certificate can be provided. 2. Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils Engineer. Recently rough graded residential developments which have a previously approved geotechnical certification are exempt from this requirement. 3. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots. 4. Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 certification number is required. 5. Attach a copy of the rough or precise grading plan to the Public Works Department showing building location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain development plan. 6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. 7. Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW approved building construction projects require either a WQMP or a completed WQMP exemption form. Approved maps/plans may be viewed at the following link: http://www.la-guirnta.org/PlanChecklm search.aspx I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff. i Recommended by: Date: / �/ 1� Public Works Distribution: ( Green Sheet to Building & Safety ( ) Green Sheet to Planning Department Declined for approval for reason(s) as follow(s), please correct and resubmit: ! I TAChecklists - Forms & AppllcationsWorms & Applications\GREEN SHEET cover & PM10 less than 1 Acre City of La Quinta - PM10 Fugitive Dust Control Project Information Construction Phase PM10 Agreement (<1 acre/lot or Infill Proiect) Prolect Information Project Phase (check one) Construction ❑ Demolition Total Acres in Active Construction (<1 acre per Lot): 23049 Contractor: Sunrose Corporation Project Name: Townsend Residence Project Tract/Lot Numbers: 29894-2 / Lot 257 Project Street Address: 53-747 Via Strada La Quinta CA 92253 � Anticipated Start Date: 04 113 /2018Anticipated Completion Date: 04 J 13 12018 PM10 Contact Please note: Dust Information construction status. non -business hours. Name: I Cole Tuvell Title: I Administration Company Name: Sunrose Corporation control is required 24 hours a day, 7 days a week, regardless of Person listed below is responsible for dust control during business and Mailing Address: 140101 Monterey Ave. B1-214 City, State, ZIP Code: I Rancho Mirage, CA 92270 Primary Phone #: � 760-218-0566 Fax M 24 Hour Emergency Phone#: 760-218-0566 Cell Phone M j same Email Address: 1_ Sunrose.sedona@gmail.com PM10 Certificate M CV1802-005850-5908 The above stated propedy owner or authorized representative : Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; ❖ Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. ❖ Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; ❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; ❖ Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes; ❖ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control plan or any City/County initiated abatement activities. - le- /E3 Signature of Property Owner or Authorized Representative Date TAChecklists - Forms & ApplicatlonsVorms & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc Water Quality Management Plan (WQMP) Exemption Form - Whitewater River Reaion Documentation of Project Not Requiring a WQMP but Requiring Site Design BMPs and Source Control BMPs by Entitlement Conditions of Approval or Permit Conditions — WQMP Required for the Listed Change of Land Uses or for Changes of Pollutant Stream (All Questions Below Must be Answered "No" To Exempt Project) Yes No Entitlement or construction of new single-family hillside residence(s) that create 10,000 square feet, or more, of impervious area where the pre -development natural slope is 25% orgreater? ❑ Entitlement or construction of new single-family hillside residence(s) that create 10,000 square feet, or more, of impervious area where the pre -development natural slope is 10% or greater where erosive soil conditions are known? ❑ ❑✓ Entitlement or construction of new commercial and industrial development(s) of 100,000 square feet more? Entitlement or construction of new automotive repair shop(s) including body, upholstery, paint, exhaust, tire, transmission, engine or other automotive specialty repair. [Standard Industrial Classification (SIC) codes 5013, 7532, 7533, 7534, 7537, 7538, and 7539]? Entitlement or construction of new retail gasoline outleffsj disturbing greater than 5,000 square feet? Entitlement or construction of new restaurant(s) (or potential restaurant shell space) disturbing greater than 5,000 square feet. Elor Fv ❑ ❑✓ ❑ ❑� ❑ Entitlement or construction of new home subdivisions with 10 or more housing units? Entitlement or construction of new parking lot(s) of 5,000 square feet or more, or with 25 or more parking spaces, and potentially exposed to Urban Runoff? ❑ ❑ Applicant Name and Title Information Mike Tuvell, President Company Sunrose Corporation Phone 760-218-0566 Email Sunrose.sedona@gmail.com Project Information Project Name Type (SFH, Multi -Family, Commercial, Etc.) Townsend Residence SFR Location or Street Address 53-747 Via Strada Via Pessaro Nearest Cross Streets Municipality/County/Zip Code La Quinta Tract Number(s) and/or Assessor Parcel Number(s) 29894-2 / 777-200-009 Other Location Information Watershed Whitewater River Source Control BMP Information Size of Project Area (nearest 0.1 acre) 23049 Project Area managed with Site Design or Low Impact Development (LID) BMPs (nearest 0.1 acre) Is the project subject to onsite retention by City ordinance or policy? yes Sunrose Corporation p Name of the Entity that will implement, operate, and maintain the Source Control BMPs Contact Name Cole Tuvell Street or Mailing Address 40101 Monterey Ave. B1-214 City Rancho Mirage Zip Code Phone 92270 760-218-0566 T:\Checklists - Forms & Applications\Forms & Applications\GREEN SHEET cover & PM10 less then 1 Acre Revised 9-25-09.doc Check Item To be Performed Source Control BMP Requirements - All Projects Require Non -Structural BMP Source Control Non -Structural BMP (See Appendix H, Section 4.5.2.1) Ongoing Irrigation System and Landscape Maintenance Ongoing Litter Control Ongoing Drainage System Inspection & Maintenance Education/Training for Property Owner, Operators, Occupants, or Employees Activity Restrictions — Prohibition of Debris Blowing/Sweeping/Washing into Street/Storm Drain, Closed Trash Lids, Restriction of Vehicle Washing Ongoing Street Sweeping at Private Streets and Private Parking Lots Check Item To be Provided Source Control BMP Requirements — Small Sloped Lots, Small Commercial, <10 Unit Subdivisions, <5,000 Square Ft. Parking Lots, Etc. Structural BMP (See Appendix H, Section 4.5.2.2) Storm Drain Inlet Stenciling and Signage Landscape and Irrigation System Design to Minimize Erosion & Nuisance Runoff Protection of Slopes and Channels to Minimize Erosion Multi -Family Project Use of Community Car Wash Racks Wash Water Controls for Food Preparation Areas to Use Sanitary Sewer Fueling Area (Design & Maintenance) Including PCC Surface, Canopy & Spill Prevention Air/Water Supply Area Drainage (Design & Maintenance) Including Spill Area Containment Trash Storage Areas (Design & Maintenance) Including Attached Lids, Storm Water Controls ❑ Loading Docks (Design & Maintenance) Including Storm Water Controls, Dry & Frequent Cleaning Procedures Maintenance Bays (Design & Maintenance) Including Indoor Location & Storm Water Containment Vehicle and Equipment Wash Areas (Design & Maintenance) Including Canopy & Containment Outdoor Material Storage Areas (Design & Maintenance) Including Canopy & Containment Outdoor Work Areas or Processing Areas (Design & Maintenance) Including Canopy & Containment CC&R's, Maintenance Agreements or Other mechanisms will be used to ensure the ongoing operation, maintenance, funding, transfer and implementation of the project -specific WQMP requirements. Legal description and plat stamped by Registered Surveyor to be attached to the applicable CC&R or Maintenance Agreement for recordation at Riverside County. (Optional Requirement to be reviewed on a Project by Project basis) BMP The applicant shall comply with listed BMPs and applicable provisions of the City's NPDES stormwater discharge permit, LQMC Sections 8.70.010 et seq. (Stormwater Management and Discharge Controls), and 13.24.170 (Clean Air/Clean Water); Riverside County Ordinance No. 457; the California Regional Water Quality Control Board — Colorado River Basin Region Board Order No. R7-2008-0001 and the State Water Resources Control Board's Order No. 99-08-DWQ. nt Signature: Print Name: Cole Tuvell Title: Administration Date: 04 / 13 12018 Phone: (760 ) 218-0566 TAChecklists - Forms & ApplicationsWorms & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc 0 Applicant Certification I certify that I have read this form in its entirety and understand the City's submittal and review process and the requirements for this form. I understand and agree that if during the processing of the form, it is determined the information contains errors or omissions, clarification and/or supplemental information may be required and the preparation of such information may be considered, in the Community Development Director's judgment, an unreasonable delay and will result in a suspension of processing time limits in accordance with the California Code of Regulations, Title 14, Section 15109. Print Name: /41/ Title - Date: -I-T4 Phone: (760) 7V2_ a �l Owner Certification I certify under the penalty of the laws of the State of California that I am the property owner of the property that is the subject matter of this application and I am authorizing and hereby do consent to the filling of this application and acknowledge that the final approval by the City of La Quinta, if any, may result in -restriction, limitations and construction obligations being imposed on this real property. Signature: Print Name: 1.tl?ip I�sIJ]y1 SAY Title: W'q ef- Date:I/ Phone: Building Permit Number: Project Description: SFR Exempt: ❑ (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Plan Submittal Date Job Site Address Owner's Name Number, Street, or PO Bo)i City, State, Postal Code Owner's Phone Number Owner's E-Mail Address Project Manager's Name Project Manager's Phone Number Project Manager's E-mail Address Builder / Contractor Number, Street or PO Box City, State, Postal Code Project Square Footage 4/13/2018 53747 Via Strada (Lot #257) Michael & Amber Townsend C/o 40101 Monterey Ave B1-214 Rancho Mirage, CA. 92270 c/o 760-702-0119 c/o Tracy Tuvell 760-702-0119 sunrose.sedona@Umall.com Sunrose Corp 40101 Monterey Ave B1-214 Rancho Mirage, CA, 92270 Approx. 8,410 sq ft City Approval By Renado Gouldlock-DEC/Burrtec Waste Date of City Approval , Is To Be Discarded: Product Tons Trash 34.50 Not recyclable Asphalt 0.00 Recyclable Brick/Block 0.00 Recyclable Cardboard 0.00 Recyclable Commingled 0.00 Recyclable Concrete 38.00 Recyclable Drywall 4.25 Recyclable Donated / Reuse* 0.00 Recyclable "Describe Items Totals: Rec cle Trash 66.9 [__ 34.5 Product Masonry (broken) Plaster Scrap Metal Tile (floor) Tile (roof) Wood Landscape Debris Tons 0.00 10.00 0.75 Recyclable 1.18 Recyclable 12.75 Recyclable 0.00 Recyclable Projected Diversion: Si5.99s I understand It is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer Q� 1 Owner / Developer 1 Project Manager / Sup erfntendant Date b j p A Inc 4i.JAI June 28 h 2018 To: The City of La Quinta Building Department. From: Brock Payton / Designer/ Project Agent Project: 53747 Via Strada (BRES2017-0314) To whom it may concern, We were recently informed during our 2nd Plan check correction (resubmittal) that our application has become expired and a request for an extension is required. The Clients, Michael and Amber Townsend, were in the process finishing another home as an income project, along with the contractor, Michael Tuvell and we all just lost track of the timeline in the process. At this point we only have a few corrections and are diligently working to get them corrected (an (11) item list from AJ Ortega received June 11). A few of the items are just small paperwork and a few are requiring a bit more work from the structural engineer. We expect this will only require us to replace a few sheets in the plans and move forward quickly. We would like to receive an extension while we add the final touches to the plans, then we can all check this off our list and move forward building this project with the help of the City of La Quinta. Our structural engineer has been on Vacation for the past week, but I would assume we could have this all finished up in a week to 10 days if we could please be granted that time. Have a great day. Sincerely, Brock Payton Brock J. Payton, Inc. 310.720.6589 Brock J Payton Inc. —1';_-! ._ N.—.. 310.720.6589 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Townsend Residence Calculation Date/Time: 14:40, Mon, Feb 12, 2018 Page 1 of 14 Calculation Description: Title 24 Analysis Input File Name: Townsend Res -Lot 257-Hideaway-Paytin-Sedona.ribd16x COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ftz-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.53 2.22 0.31 12.3% Space Cooling 77.42 75.31 2.11 1 2.7% IAQ Ventilation 0.75 0.75 0.00 0.0% Water Heating 1.95 4.28 -2.33 -119.5% Photovoltaic Offset -- 0.00 0.00 Compliance Energy Total 82.65 82.56 0.09 A ...1 Registration Number. 217-P010194533C-000-000-0000000-0000 Registration Dateffime: 2018-02-12 14:50:40 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 MAy C.��18 MY Or- LA QUIN7A OOf sjf&idi�EVELOPMe.1� tCaICERTS inc. Report Generated at: 2018-02-12 14:41:22 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Townsend Residence Calculation DatelTime: 14:40, Mon, Feb 12, 2018 Page 2 of 14 Calculation Description: Title 24 Analysis Input File Name: Townsend Res -Lot 257-Hideaway-Paytin-Sedona.ribd16x ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Titie 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 46.7 46.7 0.0 1 46.7 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit mff violate Net Energ Metering NEE rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs andlor fins • Central parallel piping HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (Oil) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • —None — Registration Number: 217-Po10194533C-00o-000-0000000-000o Registration Date/Time: 2018-02-12 14:50:40 HERS Provider CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-02-12 14:41:22 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Townsend Residence Calculation Date/Time: 14:40, Mon, Feb 12, 2018 Page 3 of 14 Calculation Description: Title 24 Analysis Input File Name: Townsend Res -Lot 257-Hideaway-Paytin-Sedona.ribd16x BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Number of Dwelling Number of Ventilation Number of Water Project Name Conditioned Floor Area (ftz) Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems Townsend Residence 8410 1 6 5 1 0 1 ZONE INFORMATION 01 02 03 04 05 Zone Floor Area Avg. Ceiling Zone Name Zone Type HVAC System Name (ft2) Height Master Bdrm Zone Conditioned HVAC-Masterl 1056 11.8 Bdrm 1, 2 & 3 Zone Conditioned Conditioned Conditioned Conditioned HVAC-Bedrooms2 HVAC-Living3 HVAC-Casita4 HVAC-2nd Floor5 1128 4526 620 1080 11.8 11.8 11.8 11.8 Great/Kit/Lou./Off Zone Casita Zone 2nd Floor Zone Registration Number: 217-PO10194533C-000-000-0000000-0000 Registration DatelTime: 2018-02-12 14:50:40 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 06 07 Water Heating System 1 1 Water Heating System 2 DHW Sys 1 n/a DHW Sys 1 n/a DHW Sys 1 n/a DHW Sys 1 n/a DHW Sys 1 n/a HERS Provider. CaICERTS inc. Report Generated at: 2018-02-12 14:41:22 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Townsend Residence Calculation Date/Time: 14:40, Mon, Feb 12, 2018 Page 4 of 14 Calculation Description: Title 24 Analysis Input File Name: Townsend Res -Lot 257-Hideaway-Paytin-Sedona.ribd16x OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) 55d Wall Master Bdrm Zone R-21 Wall 55 Right 116 24 90 235d Wall Master Bdrm Zone R-21 Wall 235 Left 120 48 90 325d Wall Master Bdrm Zone R-21 Wall 325 Back 570 277.5 90 Interior Surface Master Bdrm R-0 Interior Surface n/a n/a 793 0 n/a Zone>>Great/Kit/Lou./Off Zone Roof 2 Master Bdrm Zone R-38 Roof Attic W/ R-19 n/a n/a 1056 nla n/a 20d Wall Bdrm 1, 2 & 3 Zone R-21 Wall 20 - specify - 70 0 90 110d Wall Bdrm 1, 2 & 3 Zone R-21 Wall 110 - specify - 150 0 90 200d Wall Bdrm 1, 2 & 3 Zone R-21 Wall 200 - specify - 670 184 90 290d Wall Bdrm 1, 2 & 3 Zone R-21 Wall 290 - specify - 230 77.6 90 Interior Surface 2 Bdrm 1, 2 & 3 R-0 Interior Surface n/a n/a 680 0 n/a Zone>>Great/IGULou./Off Zone Roof 3 Bdrm 1, 2 & 3 Zone R-38 Roof Attic W/ R-19 n/a n/a 1128 n/a n/a 55d Wall 2 Great/Kit/Lou./Off Zone R-21 Wall 55 Right 1122 274.3 90 145d Wall Great/Kit/Lou./Off Zone R-21 Wall 145 Front 911 243.317 90 235d Wall 2 Great/Kit/Lou./Off Zone R-21 Wall 235 Left 527 270 90 325d Wall 2 Great/Kit/Lou./Off Zone R-21 Wall 325 Back 1021 655.008 90 Interior Surface 3 Great/Kit/Lou./Off Zone>>Bdrm 1, 2 R-0 Interior Surface n/a n/a 680 0 n/a & 3 Zone Interior Surface 4 Great/Kit/Lou./Off Zone»Master R-0 Interior Surface n/a n/a 793 0 n/a Bdrm Zone Interior Surface 5 Great/Kit/Lou./Off Zone»Casita R-0 Interior Surface n/a n/a 170 0 n/a Zone Interior Surface 6 Great/Kit/Lou./Off R-0 Interior Surface n/a nla 540 0 n/a Zone»Great/Kit/Lou./Off Zone Roof 4 Great/KiVLou./Off Zone R-38 Roof Attic W/ R-19 n/a n/a 3954 n/a n/a 55d Wall 3 Casita Zone R-21 Wall 55 Right 272 0 90 145d Wall 2 Casita Zone R-21 Wall 145 Front 419 93.7 90 235d Wall 3 Casita Zone R-21 Wall 235 Left 231 4.8 90 325d Wall 3 Casita Zone R-21 Wall 325 Back 323 56 90 Interior Surface 7 Casita Zone»Great/Kit1LouJ0ff R-0 Interior Surface n/a n/a 170 0 nla Zone Registration Number: 217-P010194533C-000-000-0000000-0000 Registration Dateffime: 2018-02-12 14:50:40 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-0205201 B-1016 SP2 Report Generated at: 2018-02-12 14:41:22 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Townsend Residence Calculation DatelTime: 14:40, Mon, Feb 12, 2018 Page 5 of 14 Calculation Description: Title 24 Analysis Input File Name: Townsend Res -Lot 257-Hideaway-Paytin-Sedona.ribdl6x Roof 5 Casita Zone 2nd Floor Zone 2nd Floor Zone 2nd Floor Zone 2nd Floor Zone 2nd Floor Zone»Great/Kit/Lou./Off Zone 2nd Floor Zone 2nd Floor Zone R-38 Roof Attic W/ R-19 R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-0 Interior Surface R-38 Roof Attic W/ R-19 R-19 Floor (F.19.2x8.16) n/a 55 145 235 325 n/a n/a n/a n/a Right Front Left Back n/a n/a n/a 620 495 335 495 323 540 1080 540 n/a 37.6 24.8 10 111.3 0 n/a n/a n/a 90 90 90 90 n/a n/a n/a 55d Wall 4 145d Wall 3 235d Wall 4 325d Wall 4 Interior Surface 8 Roof 6 Raised Floor OPAQUE SURFACES — Cathedral Ceilings 11 01 02 03 04 05 06 07 08 09 10 Orientatio Skylight Area Roof Rise Roof Roof Tilt Roof Roof Framing Type n Area (ft2) (ft2) (x in 12) Pitch (deg) Reflectance Emittance Factor Name Zone Roof Great/Kit/Lou./Off R-38 Roof Attic W/ R-191 - specify - 32.1 32 3 0.25 14.04 0.1 0.85 0.1 Zone ATTIC 03 Type Ventilated Ventilated Ventilated Ventilated Ventilated 04 Roof Rise 3 3 3 3 3 05 Roof Reflectance 0.1 0.1 0.1 0.1 0.1 06 1 Roof Emittance 0.85 0.85 0.85 0.85 0.85 07 Radiant Barrier Yes Yes Yes Yes Yes 08 Cool Roof No No No No No 01 02 Name Construction Attic Master Bdrm Zone Attic RoofMaster Bdrm Zone Attic Bdrrn 1, 2 & 3 Zone Attic RoofBdrm 1, 2 & 3 Zone Attic RoofGreat/KIVLou./Off Zone Attic RoofCasita Zone Attic Great/Kit/Lou./Off Zone Attic Casita Zone Attic 2nd Floor Zone Attic Roof2nd Floor Zone Registration Dateffime: 2018-02-12 14:50:40 HERS Provider: CaiCERTS inc Registration Number: 217-P010194533C-000-000-0000000-0000 -02052018-1016 SP2 Report Generated at: 2018-02-12 14:41:22 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Townsend Residence Calculation DatelTime: 14:40, Mon, Feb 12, 2018 Page 6 of 14 Calculation Description: Title 24 Analysis Input File Name: Townsend Res -Lot 257-Hideaway-Paytin-Sedona.ribd16x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Wig W17 D09 W15 W16 W18 W18a D10 W12 D06 RDQ7 13 14 08 14 21 D05 D01 D03 W22 D02 D12 W24 D11 W20 D13 Skylight Skylight 2 Type Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Skylight Skylight Surface {orientation -Azimuth) 55d Wall (Right-55) 235d Wall (Left-235) 235d Wall (Lest-235)1 325d Wall (Back-325) 325d Wall (Back-325) 325d Wall (Back-325) 325d Wall (Back-325) 325d Wall (Back-325) 200d Wall (- specify -200) 200d Wall (- specify -200) 200d Wall (- specify -200) 200d Wall (- specify -200) 200d Wall (- specify -200) 290d Wall (- specify -290) 55d Wall 2 (Right-55) 55d Wall 2 (Right-55) 55d Wall 2 (Right-55) 55d Wall 2 (Right-55) 145d Wall (Front-145) 145d Wall (Front-145) 145d Wall (Front-145) 235d Wall 2 (Left-235) 235d Wall 2 (Left-235) 325d Wall 2 (Back-325) 325d Wall 2 (Back-325) 325d Wall 2 (Back-325) 325d Wall 2 (Back-325) Roof (- specify -0) Roof (- specify-0) Width (ft) -- -- - -- 9.7 6.0 -- - --- 7.4 7.0 6.1 12.0 12.5 6.1 25.5 -- - Height (ft) M17.110.0 - - -- - -- 8.0 8.0 --- -23 ---- 13.5 8.0 9.5 10.0 12.0 9.5 12.0 - Multiplier 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.057 1 1.001 1 1 1.001 1 1 1 1 1 Area (ftz) 24.0 24.0 24.0 6.0 6.0 75.0 19.5 171.0 12.0 77.6 77.6 12.0 4.8 77.6 48.0 47.5 98.8 80.0 105.3 56.0 58.0 120.0 150.0 58.0 306.0 84.0 207.0 4.0 4.0 U-factor 0.22 0.22 0.27 0.22 0.22 0.22 0.22 0.25 0.22 0.25 0.25 0.22 0.22 0.25 0.27 0.22 0.22 0.25 0.94 0.25 0.22 0.25 0.25 0.22 0.25 0.22 0.25 0.21 0.21 SHGC 0.32 0.32 0.25 0.32 0.32 0.32 0.32 0.27 0.32 0.27 0.27 0.32 0.32 0.27 0.25 0.32 0,32 0.27 0.39 0.27 0.32 0.27 0.27 0.32 0.27 0.32 0.27 0.24 0.24 Exterior Shading Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Insect Screen (default) Registration Number: Registration DatelTime: g 217-P010194533C-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 2018-02-12 14:50:40 SP2 HERS Provider: CaICERTS inc. Re ort Generated at: 2018-02-12 14:41:22 P CF1 R-PRF-01 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Calculation DatelTime: 14:40, Mon, Feb 12, 2018 Page 7 of 14 Project Name: Townsend Residence File Name: Townsend Res -Lot 257-Hideaway-Paytin-Sedona.ribd16x Calculation Description: Title 24 Analysis Input Skylight Roof (- specify --0) 1 4.0 0.21 ..24 Skylight Roof (- specify --0) gEj1 4.0 0.21 0.24 ffSgkylight3 Skylight Roof (- specify -0) 1 4.0 0.21 0.24 Skylight Roof (- specify -0) 1 4.0 0.21 0.24 Skylight 7 Skylight Roof (- specify --0) 1 4.0 0.21 0.24 Skylight 8 Skylight Roof (- specify -0) 1 1 4.0 13.3 0.21 0.22 0.24 0.32 Insect Screen (default) W05 Window 145d Wall 2 (Front-145) - - 1V35 0.22 0,32 Insect Screen (default) W06 Window 145d Wall 2 (Front-145) - -- 1 0.22 0.32 Insect Screen (default) W07 Window 145d Wall 2 (Front-145) - - 1 0.22 0.32 Insect Screen (default) W08 Window 145d Wall 2 (Front-145) - - 1 0.22 0.32 Insect Screen (default) W09 Window 145d Wall 2 (Front-145) - - 1 0.22 0.32 Insect Screen (default) W10 Window 145d Wall 2 (Front-145) -- - 1 0.22 0.32 Insect Screen (default) W11 Window 235d Wall 3 (Left-235) - - 1 0.25 0,27 Insect Screen (defaW36 D04 Window 325d Wall 3 (Back-325) - - 1 0.22 0.32 Insect Screen (default) Window 55d Wall 4 (Right-55) - 6.4 0.22 0.32 Insect Screen (default) Wg5 Window 55d Wall 4 (Right-55) - 1 6.4 0.22 0.32 Insect Screen (default) W34 Window 55d Wall 4 (Right-55) -- - 1 8.0 0.22 0.32 Insect Screen (default) W33 Window 55d Wall 4 (Right-55) - - 1 10 0.22 0.32 Insect (default) Screen W32 Window 55d Wall 4 (Right-55) - -- 1 .4 5.2 0.22 0,32 Insect Screen (default) W31 Window 145d Wall 3 (Front-145) - - 1 5.2 0.22 0.32 Insect Screen (default) W30 Window 145d Wall 3 (Front-145) - -- 1 5.2 0.22 0.32 Insect Screen (default) W29 Window 145d Wall 3 (Front-145) - -- 1 5.2 0.22 0.32 Insect Screen (default) W28 Window 145d Wall 3 (Front-145) - - 4.0 0.22 0.32 Insect Screen (default) W27 Window 145d Wall 3 (Front-145) - -- 1 1 5.0 0.22 0.32 Insect Screen (default) W26 Window 235d Wall 4 (Left-235) - - 1 5.0 0.22 0.32 Insect Screen (default) W25 Window 235d Wall 4 (Left-235) - - 95.3 0.27 0.25 Insect Screen (default) D51 Window 325d Wall 4 (Back-325) 1 1 4.0 0.22 0.32 Insect Screen (default) W40 Window 325d Wall 4 (Back-325) - - 1 4.0 0.22 0.32 Insect Screen (default) W39 Window 325d Wall 4 (Back-325) - - 1 4.0 1 0.22 0,32 Insect Screen (default) W38 Window 325d Wall 4 (Back-325) - 1 4.0 0.22 0.32 Insect Screen (default) W37 Window 325d Wall 4 (Back-325) -- - 1 Registration Number: 217-P010194533C-000-000-0000000-0000 Registration DatelTime: 2018-02-12 14:50:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-02-12 14:41:22 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Townsend Residence Calculation DatelTime: 14:40, Mon, Feb 12, 2018 Page 8 of 14 Calculation Description: Title 24 Analysis Input File Name: Townsend Res -Lot 257-Hideaway-Paytin-SedonaAbd 1 6x OPAQUE DOORS 04 01 02 03 Side of Building Area (W) U-factor Name D19 I 145d Wall 24.0 0.50 OVERHANGS AND FINS 09 10 11 12 13 14 01 02 03 04 05 06 07 08 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up D10 10 0.1 10 10 0 0 0 0 0 0 0 0 0 D08 2 0.1 2 2 0 0 0 0 0 0 0 0 0 D14 4 0.1 4 4 0 0 0 0 0 0 0 0 0 D01 4 0.1 4 4 0 0 0 0 0 0 0 0 0 D03 4 0.1 4 4 0 0 0 0 0 0 0 0 0 W22 4 0.1 4 4 0 0 0 0 0 0 0 0 0 D02 4 0.1 4 4 0 0 0 0 0 0 0 0 0 D12 14 0.1 14 14 0 0 0 0 0 0 0 0 0 W24 6 0.1 6 6 0 0 0 0 0 0 0 0 0 D11 18 0.1 18 18 0 0 0 0 0 0 0 0 0 Registration Number: 217-P010194533C-000-000-0000000-0000 Registration Date[Time: 2018-02-12 14:50:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-02-12 14:41:22 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Calculation DatelTime: 14:40, Mon, Feb 12, 2018 Page 9 of 14 Project Name: Townsend Residence Input File Name: Townsend Res -Lot 257-Hideaway-Paytin-Sedona.ribdl6x Calculation Description: Title 24 Analysis OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Around Roof Joists: R-6.0 insul. • Cavity/Frame: R-13.012x4 Top Chid 2x4 Top Chord of Roof Truss @ 24 Roof Deck Wood Siding/sheathingldecking Attic RoofMaster Bdrm Zone Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.059 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Cavity/Frame: R-9.1 /2x4 Ceilings (below R-38 Roof Attic W/ R-19 attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 •Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 R-21 Wall Exterior Walls Wood Framed Wall I 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Cavity / Frame: no insul. / 2x4 R-0 Interior Surface Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.277 Other Side Finish: Gypsum Board • Around Roof Joists: R-6.0 insul. • Cavity / Frame: R-13. 0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathingldecking Attic RoofBdnn 1, 2 & 3 Zone Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.059 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-6.0 insul. • Cavity I Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofGreaUKiULou./Off Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.059 Roofing: Light Roof (Asphalt Shingle) Zone • Inside Finish: Gypsum Board • Sheathing/Insulation: R19 Sheathing • Cavity / Frame: R-36 / 2x4 • Roof Deck Wood Sidinglsheathing/decking R-38 Roof Attic W/ R-191 Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.019 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-6.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chat 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofCasita Zone Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.059 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-6.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chid 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof2nd Floor Zone Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.059 Roofing: Light Roof (Asphalt Shingle) • Floor Surface: Carpeted • Floor Deck: Wood Siding/sheathing/decking Floors Over R-19 Floor (F.19.2x8.16) Crawlspace Wood Framed Floor 2x8 @ 16 in. O.C. R 19 0.047 •Cavity/Frame: R-19/2x8 g 217-P010194533C-000-000-0000000-0000 Registration Number: Registration Date�me: 2018-02-12 14:50:40 HERS Provider: CaICERTS inc. Report Generated at: 2018-02-12 14:41:22 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Townsend Residence Calculation Date/Time: 14:40, Mon, Feb 12, 2018 Page 10 of 14 Calculation Description: Title 24 Analysis Input File Name: Townsend Res -Lot 257-Hideaway-Paytin-Sedona.ribdl6x SLAB FLOORS 01 02 03 04 05 06 07 Zone Area (ft) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Name Slab -on -Grade Master Bdrm Zone 1056 74 None 0.8 No Slab -on -Grade 2 Bdrm 1, 2 & 3 Zone 1128 119 None 0.8 No Slab -on -Grade 3 Great/Kit/Lou./Off Zone 4526 74 None 0.8 No Slab -on -Grade 4 Casita Zone 620 84 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 Quality Insulation Installation (QII) Required WATER HEATING SYSTEMS 01 Name DHW Sys 1 WATER HEATERS 01 02 03 02 Quality Installation of Spray Foam Insulation Not Required 02 03 System Type Distribution Type DHW Central Parallel Piping Heater Element Name Type Tank Type DHW Heater 1 Gas Large Storage 03 Building Envelope Air Leakage Not Required 04 Water Heater DHW Heater 1 (3) 04 05 06 07 08 09 Input Rating I Tank Standby Tank Uniform Energy Pilot 1 Insulation Loss I Number Volume Factor I Energy Thermal R-value Recovery of Units (gal) Factor I Efficiency Efficiency (IntlExt) Eff 3 100 0.86 frac 77,000 Btu/hr R-O/R-0 0.0085 05 Number of Heaters 3 04 CFM60 n/a 06 Solar Fraction (%) .0% 12 First Hour NEEA Heat Pump Tank Location Rating I Brand I Model / or Ambient Flow Rate Other I Condition n/a n/a n/a Registration Number: 217-PO10194533C-000-000-0000000-0000 Registration DatelTime: 2018-02-12 14:50:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-02-12 14:41:22 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: Townsend Residence Calculation DateMme: 14:40, Mon, Feb 12, 2018 Page 11 of 14 Calculation Description: Title 24 Analysis Input File Name: Townsend Res -Lot 257-Hideaway-Paytin-Sedona.ribd16x SPACE CONDITIONING SYSTEMS 05 06 01 02 03 04 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Other Heating and Cooling Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC-Masterl System Other Heating and Cooling Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC-Bedrooms2 System Other Heating and Cooling Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 HVAC-Livin 3 g System Other Heating and Cooling Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution System 4 HVAC-Casita4 System Other Heating and Cooling Heating Component 5 Cooling Component 5 HVAC Fan 5 Air Distribution System 5 HVAC-2nd Floor5 System HVAC - HEATING UNIT TYPES 04 01 02 03 System Type Number of Units Efficiency Name 1 80 AFUE Heating Component 1 CntdFumace Heating Component 2 CntdFumace 1 80 AFUE Heating Component 3 CntrlFumace 3 80 AFUE Heating Component 4 CntdFumace 1 80 AFUE Heating Component 5 H CntdFumace 1 80 AFUE HVAC - COOLING UNIT TYPES 07 08 01 02 03 04 05 06 Efficiency System Type Number of Units EER SEER Zonally Controlled Compressor Type HERS Verification Name Cooling Component 1 SplitAirCond 13 16 Not Zonal Single Speed 1-hers-cool ECoolingComponent SplitAirCond t 13 16 Not Zonal Single Speed Cooling Component 2-hers-cool Component 2 SplitAirCond 3 13 16 Not Zonal Single Speed Cooling Component 3-hers-cool Cooling Component 3 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 4-hers-cool Cooling Component 4 Cooling Component Cooling Component 5 SplitAirCondr 1 13 16 Not Zonal - Single Speed 5-hers-cool Registration Number: Registration Date/Time: 2018-02-12 14:50:40 HERS Provider: CaICERTS inc. g 217-P010194533C-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-02-12 14:41:22 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Townsend Residence Calculation DaterTime: 14:40, Mon, Feb 12, 2016 Page 12 of 14 Calculation Description: Title 24 Analysis Input File Name: Townsend Res -Lot 257-Hideaway-Paytin-Sedona.ribdl6x HVAC COOLING - HERS VERIFICATION 01 Name Cooling Component 1-hers-cool Cooling Component 2-hers-cool Cooling Component 3-hers-cool Cooling Component 4-hers-cool Cooling Component 5-hers-cool HVAC - DISTRIBUTION SYSTEMS 02 03 04 05 06 Verified Refrigerant Verified Airflow Airflow Target Verified EER Verified SEER Charge Required 350 Required Required Required Required 350 Required Required Required Required 350 Required Required Required Required 350 Required Required Required Required 350 Required Required Required 01 02 Name Type Air Distribution System 1 DuctsAttic Air Distribution System 2 DuctsAttic Air Distribution System 3 DuctsAttic Air Distribution System 4 DuctsAttic Air Distribution System 5 DuctsAttic HVAC DISTRIBUTION - HERS VERIFICATION 01 1 02 Name Air Distribution System 1-hers-list Air Distribution System 2-hers-list Air Distribution System 3-hers-dist Air Distribution System 4-hers-dist Air Distribution System 5-hers-dist Duct Leakage Verification Required Required Required Required Required 03 04 05 06 07 Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Specified Lower Leakage 8 Attic None Air Distribution System 1-hers-list Target Air Distribution System Specified Lower Leakage 8 Attic None 2-hers-dist Target Air Distribution System Specified Lower Leakage B Attic None 3-hers-dist Target Air Distribution System Specified Lower Leakage 8 Attic None 4-hers-dist Target Air Distribution System Specified Lower Leakage 8 Attic None 5-hers list Target 03 04 05 06 07 08 Duct Leakage Verged Duct Verified Duct Buried Deeply Buried Low -leakage Target (%) Location Design Ducts Ducts Air Handler 5.0 Not Required Not Required Not Required Not Required Required 5.0 Not Required Not Required Not Required Not Required Required 5.0 Not Required Not Required Not Required Not Required Required 5.0 Not Required Not Required Not Required Not Required Required 5.0 Not Required Not Required Not Required Not Required Required Registration Number: 217-P010194533C-000-000-0000000-0000 Registration Date/Time: 2018-02-12 14:50:40 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-0205201 &1016 SP2 Report Generated at: 2018-02-12 14:41:22 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Townsend Residence Calculation Date/Time: 14:40, Mon, Feb 12, 2018 Page 13 of 14 Calculation Description: Title 24 Analysis Input File Name: Townsend Res -Lot 257-Hideaway-Paytin-Sedona.ribdl6x HVAC-FAN SYSTEMS 01 02 Type Single Speed PSC Furnace Fan Single Speed PSC Furnace Fan Single Speed PSC Furnace Fan Single Speed PSC Furnace Fan Single Speed PSC Furnace Fan 03 Fan Power (WattsICFM) 0.54 0.54 0.54 0.54 0.54 Name HVAC Fan 1 HVAC Fan 2 HVAC Fan 3 HVAC Fan 4 HVAC Fan 5 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 Name Verified Fan Watt Draw HVAC Fan 1-hers-fan Required HVAC Fan 2-hers-fan Required HVAC Fan 3-hers-fan Required HVAC Fan 4-hers-fan Required Required HVAC Fan 5-hers-fan IAQ (Indoor Air Quality) FANS 01 02 03 04 Dwelling Unit IAQ CFM IAQ Watts1CFM IAQ Fan Type SFam IAQVentRpt 137 0.25 Default 04 HERS Verification HVAC Fan 1-hers-fan HVAC Fan 2-hers-fan HVAC Fan 3-hers-fan HVAC Fan 4-hers-fan HVAC Fan 5-hers-fan 03 Required Fan Efficiency (Watts/CFM) 0.54 0.54 0.54 0.54 0.54 05 IAQ Recovery Effectiveness(%) 0 06 HERS Verification Required Registration Number: 217-P010194533C-000.000-0000000.0000 Registration DateMme: 2018-02-12 14:50:40 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 Report Generated at: 2018-02A2 14:41:22 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Townsend Residence Calculation DatelTime: 14:40, Mon, Feb 12, 2018 Calculation Description: Title 24 Analysis Input File Name: Townsend Res -Lot 257-Hideaway-Paytin-Sedona.ribd16x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Tim Scott Company: Scott Design and Title 24, Inc. Address: 77085 Michigan Drive City/State/Zip: Palm Desert, CA 92211 RESPONSIBLE PERSON'S DECLARATION STATEMENT Documentation Author Signature: Tz;W&�c011r Signature Date: 2018-02-12 14:50:40 CEA/HERS Certification Identification (If applicable): Phone: 760-200-4780 CFI R-PRF-01 Page 14 of 14 I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Tim Scott Company: Scott Design and Title 24, Inc. Address: 77085 Michigan Drive City/State/Zip: Palm Desert, CA 92211 Responsible Designer Signature: �LfYi�CB�I Date Signed: 2018-02-12 14:50:40 License: NA Phone: 760-2004780 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 217-P010194533C-000-000-0000000-0000 Registration DatelTime: 2018-02-12 14:50:40 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02052018-1016 SP2 W-1 Easy to Verify at CaICERTS.com HERS Provider. CaICERTS inc. Report Generated at: 2018-02-12 14:41:22