Loading...
BRES2018-0279OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: I ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. . B.&P.C. for this reason 78-495 CALLE TAMPICO Twit D 4QuIAto LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTM BUILDING PERMIT Permit Type/Subtype: BUILDING RESIDENTIAL/DWELLING -SINGLE FAMILY DETACHED Application Number: BRES2018-0279 Property Address: 59895 SEVILLE APN: 764710017 Application Description: ANDALUSIA / NEW SFD / PLAN 25C MODIFICATION Property Zoning: Application Valuation: $551,358.10 Applicant: T D DESERT DEVELOPMENT LIMITED PARTNERSH 81570 CARBONERAS LA QUINTA, CA 92253 ----------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter I hereby affirm under penalty of perjury one of the following declarations: 9 {commencing with Section 7000) of Division 3 of the Business an fessions Code, I have and will maintain a certificate of consent to self -insure for workers' and my License is in full force and effect. compensation, as provided for by Section 3700 of the Labor Code, for the performance License Class: License No.: 29 of"37,n hich this permit is issued. i r - and will maintain workers' compensation insurance, as required by Date: r' �/ ' Contrae r �eehe Labor Code, forthe performance of the work for which this permit is issued. My arkers' compensation insurance carrier and policy number are: Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD503905300 Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 ENT INSPECTIONS (760) 777-7153 Date: 1/11/2019 Owner: v rn T D DESERT DEV cn G? 81570 CARBONERAS LA QU I NTA, CA 0 v n D 3� CD z D m --I r� Contractor: m y rcm T D DESERT DEVELOPMENT LIMBED PARTNERSH� 81570 CARBONERAS LA QUINTA, CA 92253 �O—I M (760)777-1001 Llc. No.: 762987 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Cod forthwith comply with vse p ovlsivns. t Date: / Appll nt: WARNING: FAILURE TO SECURE WORKERS' CON(P6PFS�ON COVERAGE IS U WFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINE UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit Issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 190 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above infar on is correct. I agree to comply with all city and county ordinances and state la rela g to building construction, and hereby authorize represenMocpon the above-menti ned roperty for inspection puDate: /� Signature (Applica Date; 1/11/2019 Application Number: BRES2018-0279 Property Address: 59895 SEVILLE APN: 764710017 Application Description: ANDALUSIA / NEW SFD / PLAN 25C MODIFICATION Property Zoning: Application Valuation: $551,358.10 Applicant: T D DESERT DEVELOPMENT LIMITED PARTNERSH 81570 CARBONERAS ; LA .QU I NTA, CA 92253 Owner: T D DESERT DEV 81570 CARBONERAS LA QU I NTA, CA 0 Contractor: T D DESERT DEVELOPMENT LIMITED PARTNERSH 81570 CARBONERAS LA QUINTA, CA 92253 (760)777-1001 Llc. No.: 762987 Detail: SITE SPECIFIC MODIFICATION OF APPROVED TRACT PLAN 25C TO ADD AN ART STUDIO, POOL BATH, DEN ADDITION AND OUTDOOR COVERED PATIO AREA FOR A TOTAL OF 6,228SF LIVING SPACE. [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2016 CALIFORNIA BUILDING CODE. DESCRIPTION ACCOUNT CITY AMOUNT ART IN PUBLIC PLACES - RESIDENTIAL 270-0000-43201 0 $878.39 Total Paid for ART IN PUBLIC PLACES - AIPP: $878.39 DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $23.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $23.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - LIBRARIES 253-0000-43200 0 $344.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARKS/REC 251-0000-43200 0 $2,048.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 DESCRIPTION ACCOUNT CITY AMOUNT SERVICES 101-0000-42403 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT SERVICES PC 101-0000-42600 0 $13.00 Total Paid for ELECTRICAL: $39.01 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $92.82 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $38.22 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $156.04 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $51.49 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $338.57 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL PRECISE GRADING - TRACT HOME 101-0000-42408 0 $143.56 Total Paid for GRADING: $143.56 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $156.04 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $104.04 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD 101-0000-42402 0 $13.00 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD PC 101-0000-42600 0 $5.20 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE 101-0000-42402 0 $156.04 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE PC 101-0000-42600 0 $104.04 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN 101-0000-42402 0 $104.00 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN PC 101-0000-42600 0 $41.60 Total Paid for MECHANICAL: $683.96 DESCRIPTION ACCOUNT CITY AMOUNT MULTI -SPECIES RESIDENTIAL 0-8 UNITS - 2018 UPDATE 101-0000-20310 0 $1,290.00 DESCRIPTION ACCOUNT QTY AMOUNT MULTI -SPECIES RESIDENTIAL 0-8 UNITS - 2018 UPDATE 101-0000-20310 0 $1,290.00 Total Paid for MULTI -SPECIES RESIDENTIAL: $2,S80.00 DESCRIPTION ACCOUNT CITY AMOUNT NEW CONSTRUCTION PERMIT 101-0000-42400 0 $840.44 Total Paid for NEW CONSTRUCTION PERMIT: $840.44 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,812.11 Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,812.11 DESCRIPTION ACCOUNT QTY AMOUNT BACKFLOW DEVICE 101-0000-42401 0 $13.00 DESCRIPTION ACCOUNT QTY AMOUNT BACKFLOW DEVICE PC 101-0000-42600 0 $5.20 DESCRIPTION ACCOUNT CITY AMOUNT BUILDING SEWER 101-0000-42401 0 $26.01 DESCRIPTION ACCOUNT QTY AMOUNT BUILDING SEWER PC 101-0000-42600 0 $18.20 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $273.00 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $273.00 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $39.01 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $26.00 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $15.60 DESCRIPTION ACCOUNT CITY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $13:00 DESCRIPTION ACCOUNT CITY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $13.00 Total Paid for PLUMBING FEES: $741.03 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $71.68 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $71.68 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT CITY AMOUNT SINGLE FAMILY DETACHED 2018 UPDATE 224-0000-20320 0 $2,310.00 Total Paid for TUMF - RESIDENTIAL: $2,310.00 Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 Project Name: Andalusia Country Club Owner's Name: Sunrise LQ, LLC Project Address: 59-895 Seville, LaQuinta Project Description: APN: 764-710-017 New Single Family This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT; LEVEL TWO AMOUNT: MITIGATION AMOUNT: I COMMAND. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Tract #: Type of Development: Residential xx Commercial Total Square Feet of Building Area: 6,228 sq. ft. Date: December 20, 2018 Phone No. 760-777-1000 Lot #'s: Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer, Dated: December 20, 2018 Signature: ***************************************************1-"***************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code 65995 6228 $3.79 $23604.12 Building Permit Application Completed: Yes/No By: Larry Moen, Director Facilities Dev. & Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement Note: Pursuant to AB 181 any room additions or enclosures of 500 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within the same school district's jurisdiction are exempt from developer fees. Certificate issued by: Laurie Howard, Administrative Spec. Signature: r4t�V/�w ac NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90-day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90-day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. 11/2010 Bin #City ►`� of La Qulnta Building & Safety Division P.O. Box 1504, 78-495 Calk Tampico La.Quinta, G4 92253 - (760) 777-70I2 Budding Permit Application and Tracking Sheet Permit 71 I� Project Address: 51 8 75 $.e V % I ( e Owner's Name: % . � Ps t i ��J ei❑ • L L A. P. Number: 7 M *' % (ap ( % Address: 6 ( 5'to t�['r Legal Description: -Tr*&: 31 (O C Q City, ST, Zip: (-e, fyL4c, C + Q 2 Z- Contractor.-; p _ 0'—'ef - if, ie)a '14 e'L7�_ L , Telephone:'7G7c, t �1 PZ ( � Address: Prajet t Description: I City, ST, Zip: �.j t.t • � CA ct Z2-53 'z f 1C Telephone..'760 1-11 (�a- I= t++ f of q �C r CI ►Q State Lic. #: -7lp L T O -7 City Lic. 72 J � �,7 f � it ♦ � 1 i f �f'►a � yr� Arch., Engr., Designer. L. Address: Ij- f�'� �7 City, ST, Zip: Pr fj u 2-1 10 Telephone: State Lic. #: Name of Contact Person: /� Gg .I Construction Type: Occupancy: Project type (circle wie): New Add'u Alter Repair Demo ] � 5 Sq. Ft.: � Z Z # Stories: # Units: Telephone # of Contact Person: i lb o n D i�-> o L o Estimated Value of Project APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Reed TRACENG PERMITFEES Plan Sets Plan Check submitted Beat Amount Structural CaicS. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flow plain plan Plans resubmitted Mecbartical Grading plan Z'iReview, ready for correctionsrmue Electrical Subcontattor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading M HOUSE:•. '"` Review, ready for cormcdonsJUsae Developer Impact Fee Planning Approval Called Contact Person A I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees Building Permit Number: Project Description: �SFR� Exempt: ❑ (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Plan Submittal Date Job Site Address Owner's Name Number, Street, or PO Box City, State, Postal Code Owner's Phone Number Owner's E-Mail Address Project Manager's Name Project Manager's Phone Number Project Manager's E-mail Address Builder / Contractor Number, Street or PO Box City, State, Postal Code Project Square Footage City Approval By Date of City Approval 1/10/2019 5�895 Seville (lot #191) Sunrise LQ, LLC 81570 Carboneras La Quinta, CA. 92253 c/o 760-408-0108 Nolan Sparks 760-408-0106 N$Aarkr{7a rancholaouirta.com Sunrise LQ, LLC 81570 Carboneras La Quinta, CA. 92253 Approx. 4,502 sq ft Renado Gouldlock-DEC/Burrtec Waste ti . �)I ) iv h I Materials To Be Discarded: Product Tons Trash 19.00 Not recyclable Asphalt 0.00 Recyclable Brick/Block 0.00 Recyclable Cardboard 0.00 Recyclable Commingled 0.00 Recyclable Concrete 21.00 Recyclable Drywall 2.25 Recyclable Donated / Reuse* 0.00 Recyclable *Describe Items Totals: Recycle Trash 37.8 1 19.0 Product Masonry (broken) Plaster Scrap Metal Tile (floor) Tile (root)i Wood Landscape Debris Tons 0.00 5.50 0.00 0.40 0.60 8.00 0.00 Projected Diversion: BIi.l52°/0 I understand It Is the property owners responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, Implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property ow s) and a owner retains legal responsibility for ensuring that the provisions of the DMP are adhe a perty ner(s) a general contractor shall be kept informed of the diversion progress through bi-monthly ports. If self- ulln , all refuse aterfaI from this project site must betaken to an approved cycler or transfer C' Own r`t-QeveloperI PFrole&Agarrhger / S u perin tendbot Date EsGil A SAC Ebuilt Company DATE: December 3, 2018 JURISDICTION: La Quinta PLAN CHECK #.: BRES2018-0279 REV SET: II PROJECT ADDRESS: 59895 Seveille PROJECT NAME: Andalusa, Lot 191 Add Art Studio ❑ APPLICANT ❑ JURIS. ® The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ❑ The applicant's copy of the check list has been sent to: ® EsGil staff did not advise the applicant that the plan check has been completed. ❑ EsGil staff did advise the a licant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: 0 Email: Mail Telephone Fax In Person ❑ REMARKS: By: Kurt Culver EsGil 11/14/18 Enclosures: Previously -approved plans 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: lot 191 art studio Calculation Description: Title 24 Analysis Calculation Date/Time: 10:51, Fri, Oct 05, 2018 Input File Name: Andalusia -Lot 191-Pekerek-18.ribd16x CF1 R-PRF-01 Page 1 of 10 GENERAL INFORMATION 01 Project Name lot 191 art studio 02 Calculation Description Title 24 Analysis 03 Project Location Coral Mountains 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 1460 15 Number of Zones 1 16 Slab Area (ft2) 1460 17 Number of Stories 1 18 Addition Cond. Floor Area(ft2) n/a 19 Natural Gas Available yes 20 Addition Slab Area (ft2) n/a 21 Glazing Percentage (%) 25.3% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Poa-r D� O CITY OF LA CCU DIVISIONLDING NA B REVIEWED FOR CODE COMPLIANCE JF DATE Il 0 �L 2 BY -a271-f Registration Number: 218-P010150253E-000-000-0000000-0000 Registration Dateffime: 2018-10-05 10:55:49 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 CFI Cc 6'ovPy V; HERS Provider: CaICE 7S inc. Report Generated at: 2018-10-05 10:51:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: lot 191 art studio Calculation Date/Time: 10:51, Fri, Oct 05, 2018 CF1 R-PRF-01 Page 2 of 10 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Pekerek-18.ribdl6x ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 0.67 1.90 -1.23 -183.6% Space Cooling 98.84 72.33 26.51 26.8% IAQ Ventilation 1.40 1.40 0.00 0.0% Water Heating 8.50 17.15 -8.65 -101.8% PV Credit 0.00 0.00 .--- North Facing Compliance Total 109.41 92.78 16.63 15.2% Space Heating 0.67 1.89 -1.22 -182.1% Space Cooling 98.84 77.25 21.59 21.8% IAQ Ventilation 1.40 1.40 0.00 0.0% Water Heating 8.50 17.15 -8.65 -101.8% PV Credit 0.00 0.00 -- East Facing Compliance Total 109.41 97.69 11.72 10.7% Space Heating 0.67 1.91 -1.24 -185.1% Space Cooling 98.84 72.01 26.83 27.1% IAQ Ventilation 1.40 E Ro 1.40 0.00 0.0% Water Heating 8.50 17.15 -8.65 -101.8% PV Credit --- 0.00 0.00 - South Facing Compliance Total 109.41 92.47 16.94 15.5% Space Heating 0.67 2.00 -1.33 -198.5% Space Cooling 98.84 73.25 25.59 25.9% IAQ Ventilation 1.40 1.40 0.00 0.0% Water Heating 8.50 17.15 -8.65 -101.8% PV Credit ... 0.00 0.00 --- West Facing Compliance Total 109.41 93.80 15.61 14.3% Registration Number: 218-P010150253E-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:55:49 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:51:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: lot 191 art studio Calculation Description: Title 24 Analysis Calculation DatelTime: 10:51, Fri, Oct 05, 2018 Input File Name: Andalusia -Lot 191-Pekerek-18.ribdl6x Page 3 of 10 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR North 56.7 50.8 0.0 50.8 East 56.7 52.5 0.0 52.5 South 56.7 50.7 0.0 50.7 West 56.7 51.2 0.0 51.2 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. Notes: - Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Materin (NEM) rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. Cool roof • Insulation below roof deck • Window overhangs and/or fins • Central parallel piping Registration Number: 218-P010150253E-000-000-0000000-0000 Registration Date(fime: 2018-10-05 10:55:49 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:51:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: lot 191 art studio Calculation Date/Time: 10:51, Fri, Oct 05, 2018 CFI R-PRF-01 Page 4 of 10 Calculation Description: Title 24 Analysis HERS FEATURE SUMMARY Input File Name: Andalusia -Lot 191-Pekerek-18.ribdl6x The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow, • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Wafts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • --None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems lot 191 art studio 1460 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 art studio Conditioned HVAC1 1460 9 DHW Sys 1 n/a OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) N Wall art studio R-21 Wall (W.21.2x6.16) 0 Front 560 49.5 90 E Wall art studio R-21 Wall (W.21.2x6.16) 90 Left 230 41.415 90 S Wall art studio R-21 Wall (W.21.2x6.16) 180 Back 560 178.114 90 W Wall art studio R-21 Wall (W.21.2x6.16) 270 Right 230 100.512 90 Interior Surface art studio R-0 Interior Wall n/a n/a 288 0 n/a Roof art studio R-38 Roof Attic n/a n/a 1460 n/a n/a Registration Number: 218-P010150253E-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:55:49 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:51:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: lot 191 art studio Calculation Date/Time: 10:51, Fri, Oct 05, 2018 CF1 R-PRF-01 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Pekerek-18.ribdl6x Page 5 of 10 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic art studio Attic Roofart studio Unventilated 3 0.3 0.75 Yes Yes FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading 3 2x2 ---- .30./.17 Window N Wall (Front-0) 2.0 2.0 1 4.0 0.30 0.17 Insect Screen (default) 4 2x2 ---- .30./.17 Window N Wall (Front-0) 2.0 2.0 1 4.0 0.30 0.17 Insect Screen (default) 5 2x2 ---- .30./.17 Window N Wall (Front-0) 2.0 2.0 1 4.0 0.30 0.17 Insect Screen (default) 6 2x2 ---- .30./.17 Window N Wall (Front-0) 2.0 2.0 1 4.0 0.30 0.17 Insect Screen (default) 7 2x2 ---- .30./.17 Window N Wall (Front-0) 2.0 2.0 1 4.0 0.30 0.17 Insect Screen (default) 8 2x2 ---- .30./.17 Window N Wall (Front-0) 2.0 2.0 1 4.0 0.30 0.17 Insect Screen (default) 9 2x2 ---- .30./.17 Window N Wall (Front-0) 2.0 2.0 1 4.0 0.30 0.17 Insect Screen (default) 10 2x2 ---- .30./.17 Window N Wall (Front-0) 2.0 2.0 1 4.0 0.30 0.17 Insect Screen (default) 11 2x2 ---- .30./.17 Window N Wall (Front-0) 2.0 2.0 1 4.0 0.30 0.17 Insect Screen (default) 12 2x2 ---- .30./.17 Window N Wall (Front-0) 2.0 2.0 1 1 4.0 0.30 0.17 Insect Screen (default) 13 2x2 ---- .30./.17 Window N Wall (Front-0) 2.0 2.0 1 4.0 0.30 0.17 Insect Screen (default) 14 1x5.5 ---- .30./.17 Window N Wall (Front-0) 1.0 5.5 1 5.5 0.30 0.17 Insect Screen (default) 15 2.5x5.5 ---- .30./.17 Window E Wall (Left-90) 2.5 5.5 1.004 13.8 0.30 0.17 Insect Screen (default) 16 2.5x5.5 ---- .30./.17 Window E Wall (Left-90) 2.5 5.5 1.004 13.8 0.30 0.17 Insect Screen (default) 17 2.5x5.5 ---- .30./.17 Window E Wall (Left-90) 2.5 5.5 1.004 13.8 0.30 0.17 Insect Screen (default) 18 1x6.5 ---- .30./.17 Window S Wall (Back-180) 2.5 5.5 0.473 6.5 0.30 0.17 Insect Screen (default) 19 2.5x5.5 ---- .30./.17 Window S Wall (Back-180) 2.5 5.5 1.004 13.8 0.30 0.17 Insect Screen (default) 20 2.5x5.5 ---- .30./.17 Window S Wall (Back-180) 2.5 5.5 1.004 13.8 0.30 0.17 Insect Screen (default) 21 6x8 ---- .32.30 Window S Wall (Back-180) 6.0 8.0 1 48.0 0.30 0.20 Insect Screen (default) 22 6x8 ---- .32.30 Window S Wall (Back-180) 6.0 8.0 1 48.0 0.30 0.20 Insect Screen (default) 23 6x8 ---- .32.30 Window S Wall (Back-180) 6.0 8.0 1 48.0 0.30 0.20 Insect Screen (default) 1 1.5x3 ---- .32.30 Window W Wall (Right-270) 6.0 8.0 0.094 4.5 0.30 0.20 Insect Screen (default) 2 12x8---- .32.30 Window W Wall (Right-270) 6.0 8.0 2 96.0 0.30 0.20 Insect Screen (default) Registration Number: 218-P010150253E-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:55:49 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:51:43 CF1 R-PRF-01 Page 6 of 10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: lot 191 art studio Calculation Date/Time: 10:51, Fri, Oct 05, 2018 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Pekerek-18.ribd16x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 3 2x2 ---- .30./.17 6 0.1 6 6 0 0 0 0 0 0 0 0 0 4 2x2 ---- .30.1.17 6 0.1 6 6 0 0 0 0 0 0 0 0 0 5 2x2 ---- .30./.17 6 0.1 6 6 0 0 0 0 0 0 0 0 0 6 2x2 ---- .30./.17 6 0.1 6 6 0 0 0 0 0 0 0 0 0 7 2x2 ---- .30./.17 6 0.1 6 6 0 0 0 0 0 0 0 0 0 8 2x2 --- .30./.17 6 0.1 6 6 0 0 0 0 0 0 0 0 0 9 2x2 ---- .30./.17 6 0.1 6 6 0 0 0 0 0 0 0 0 0 10 2x2 ---- .30./.17 6 0.1 6 6 0 0 0 0 0 0 0 0 0 11 2x2 ---- .30./.17 6 0.1 6 6 0 0 0 0 0 0 0 0 0 12 2x2 ---- .30./.17 13 2x2 ---- .30./.17 14 1 x5.5 ---- .30./.17 15 2.5x5.5 ---- .30./.17 16 2.5x5.5 ---- .30./.17 17 2.5x5.5 ---- .30./.17 18 1 x6.5 --- .30./.17 6 6 6 6 6 6 6 0.1 0.1 0.1 0.1 0.1 0.1 0.1 6 6 6 6 6 6 6 6 6 6 6 6 6 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 19 2.5x5.5 ---- .30./.17 20 2.5x5.5 ---- .30./.17 6 6 0.1 0.1 6 6 6 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 21 6x8 ---- .32.30 18 0.1 18 18 0 0 0 0 0 0 0 0 0 22 6x8 ---- .32.30 23 6x8 ---- .32.30 1 1.5x3 ---- .32.30 2 12x8---- .32.30 18 18 18 18 0.1 0.1 0.1 0.1 18 18 18 18 18 18 18 18 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Registration Number: 218-P010150253E-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:55:49 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:51:43 CF1 R-PRF-01 Page 7 of 10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: lot 191 art studio Calculation Date/Time: 10:51, Fri, Oct 05, 2018 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Pekerek-18.ribd16x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Around Roof Joists: R-6.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofart studio Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.059 Roofing: Light Roof (Asphalt Shingle) Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Cavity / Frame: no insul. / 2x4 R-0 Interior Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.277 Other Side Finish: Gypsum Board SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Covered Slab ex art studio 1460 88 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Central Parallel Piping DHW Heater 1 (1) 1 .0% Registration Number: 218-P010150253E-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:55:49 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:51:43 CF1 R-PRF-01 Page 8 of 10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: lot 191 art studio Calculation Date/Time: 10:51, Fri, Oct 05, 2018 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Pekerek-18.ribdl6x WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot I Thermal Efficiency Tank Insulation R-value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model / Other Tank Location or Ambient Condition DHW Heater 1 Gas Large Storage 1 75 0.76 TE 76,000 Btu/hr R-0/R-0 0.02 n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC1 Heat Pump Heating and Cooling System Heat Pump System 1 Heat Pump System 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP I Cap 47 Cap 17 SEER EER Heat Pump System 1 SplitHeatPump 1 8.2 32500 19920 15 12.2 Not Zonal Single Speed Heat Pump System 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 1 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Heat Pump System 1-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a Registration Number: 218-P010150253E-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:55:49 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:51:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: lot 191 art studio Calculation Date/Time: 10:51, Fri, Oct 05, 2018 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Pekerek-18.ribd16x CF1 R-PRF-01 Page 9 of 10 HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 45 0.25 Default 0 Required � CaICERTS,I Inc. Registration Number: 218-P010150253E-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:55:49 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:51:43 CF1 R-PRF-01 Page 10 of 10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: lot 191 art studio Calculation Date/Time: 10:51, Fri, Oct 05, 2018 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Pekerek-18.ribdl6x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: TuW,.�cor Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2018-10-05 10:55:49 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature, Tim Scott%'b.0 Company: H r Date Signed: Scott Design and Title 24, Inc. E 2018-10-05 10:55:49 Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 0 Easy to Verify at CaICERTS.com Registration Number: 218-P010150253E-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:55:49 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 HERS Provider: CaICERTS inc. Report Generated at: 2018-10-05 10:51:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 191 Main w casita Residence Calculation Date/Time: 10:21, Fri, Oct 05, 2018 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Main-Plan 25-Pekerek-18.ribd16x CF1 R-PRF-01 Page 1 of 12 GENERAL INFORMATION 01 Project Name Lot 191 Main w casita Residence 02 Calculation Description Title 24 Analysis 03 Project Location Coral Mountains 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) Cardinal 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 4502 15 Number of Zones 1 16 Slab Area (ft) 4502 17 Number of Stories 1 18 Addition Cond. Floor Area(ft2) n/a 19 Natural Gas Available yes L720 Addition Slab Area (ftZ) n/a 21 Glazing Percentage (%) 20.1% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below - M A, 1'i �6usca. CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE L N (017'018 BY Registration Number: 218-P010262971C-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:33:18 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Oir Y `� 1.3 HERS Provider. CaICERTS lrxc. Report Generated at: 2018-10-0510:22:35 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 191 Main w casita Residence Calculation Date/Time: 10:21, Fri, Oct 05, 2018 CFI R-PRF-01 Page 2 of 12 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Main-Plan 25-Pekerek-18.ribd16x ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/ft2-yr) Design Design Margin Improvement Space Heating 1.84 2.92 -1.08 -58.7% Space Cooling 80.04 64.20 15.84 19.8% IAQ Ventilation 0.77 0.77 0.00 0.0% Water Heating 2.88 8.50 -5.62 -195.1% PV Credit 0.00 0.00 --- North Facing Compliance Total 85.53 76.39 9.14 10.7% Space Heating 1.84 2.91 -1.07 -58.2% Space Cooling 80.04 58.20 21.84 27.3% IAQ Ventilation 0.77 0.77 0.00 0.0% Water Heating 2.88 8.50 -5.62 -195.1% PV Credit - 0.00 0.00 --- East Facing Compliance Total 85.53 70.38 15.15 17.7% Space Heating 1.84 2.75 -0.91 -49.5% Space Cooling 80.04 60.93 19.11 23.9% IAQ Ventilation 0.77 ' CEP8.50 0.77 1 n 0.00 0.0% Water Heating 2.88 5.62 -195.1% PV Credit i- t 5 S # i ti _ 0.00 E) [ .• 0.00 South Facing Compliance Total 85.53 72.95 12.58 14.7% Space Heating 1.84 2.99 -1.15 -62.5% Space Cooling 80.04 58.06 21.98 27.5% IAQ Ventilation 0.77 0.77 0.00 0.0% Water Heating 2.88 8.50 -5.62 -195.1% PV Credit ---- 0.00 0.00 ---- West Facing Compliance Total 85.53 70.32 15.21 17.8% Registration Number: 218-P010262971C-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:33:18 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:22:35 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 191 Main w casita Residence Calculation Date/Time: 10:21, Fri, Oct 05, 2018 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Main-Plan 25-Pekerek-18.ribd16x CF1 R-PRF-01 Page 3 of 12 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR North 49.5 45.2 0.0 45.2 East 49.5 42.4 0.0 42.4 South 49.5 43.6 0.0 43.6 West 49.5 42.3 0.0 42.3 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. rNotes_photovoltaic : Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (HEM) rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Insulation below roof deck • Window overhangs and/or fins • Central parallel piping Registration Number: 218-P010262971C-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:33:18 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:22:35 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 191 Main w casita Residence Calculation Date/Time: 10:21, Fri, Oct 05, 2018 CF1 R-PRF-01 Page 4 of 12 Calculation Description: Title 24 Analysis HERS FEATURE SUMMARY Input File Name: Andalusia -Lot 191-Main-Plan 25-Pekerek-18.ribd16x The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • --None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Lot 191 Main w casita Residence 4502 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ftZ) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 residence Conditioned HVAC1 4502 9 DHW Sys 1 n/a OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ftZ) Window & Door Area (ftZ) Tilt (deg) N Wall residence R-21 Wall (W.21.2x6.16) 0 Front 1280 125 90 E Wall residence R-21 Wall (W.21.2x6.16) 90 Left 920 206.8 90 S Wall residence R-21 Wall (W.21.2x6.16) 180 Back 1280 150.416 90 W Wall residence R-21 Wall (W.21.2x6.16) 270 Right 920 448.015 90 Interior Surface residence R-13 Wall n/a n/a 388 0 n/a Roof residence R-38 Roof Attic n/a n/a 4502 n/a n/a Registration Number: 218-P010262971C-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:33:18 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:22:35 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 191 Main w casita Residence Calculation Date/Time: 10:21, Fri, Oct 05, 2018 CF1 R-PRF-01 Page 5 of 12 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Main-Plan 25-Pekerek-18.ribd16x ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic residence I Attic Roofresidence Ventilated 3 0.3 0.75 Yes Yes � CaICERTS,I Inc. Registration Number: 218-P010262971C-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:33:18 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:22:35 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 191 Main w casita Residence Calculation Date/Time: 10:21, Fri, Oct 05, 2018 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Main-Plan 25-Pekerek-18.ribdl6x CF1 R-PRF-01 Page 6 of 12 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading _= 1.5x3---- .32.30 Window N Wall (Front-0) 2.0 2.0 1 4.0 0.32 0.30 Insect Screen (default) 21 --- .32.30 Window N Wall (Front-0) 2.0 2.0 1 4.0 0.32 0.30 Insect Screen (default) 22 ---- .32.30 Window N Wall (Front-0) 5.0 5.5 1 27.5 0.32 0.30 Insect Screen (default) =6x8 38---- .32.30 Window N Wall (Front-0) 3.0 8.0 2 48.0 0.32 0.30 Insect Screen (default) ==2x3 39---- .38.35 Window N Wall (Front-0) ---- -- 1 6.0 0.38 0.35 Insect Screen (default) 30 ---- .32.30 Window N Wall (Front-0) 1.5 3.0 1 4.5 0.32 0.30 Insect Screen (default) ===1.5x3 ---- .38.35 Window N Wall (Front-0) 1.5 3.0 1 4.5 0.38 0.35 Insect Screen (default) 31 ---- .30.17 Window N Wall (Front-0) 1.5 3.0 1 4.5 0.30 0.17 Insect Screen (default) 1 ---- .30.17 Window N Wall (Front-0) 2.0 5.5 1 11.0 0.30 0.17 Insect Screen (default) 2 - .30.17 Window N Wall (Front-0) 2.0 5.5 1 11.0 0.30 0.17 Insect Screen (default) 24 ---- .32.30 Window E Wall (Left-90) 9.0 12.0 1 108.0 0.32 0.30 Insect Screen (default) 25 ---- .32.30 Window E Wall (Left-90) 6.0 1 8.0 1 48.0 0.32 0.30 Insect Screen (default) 43 ---- .38.35 Window E Wah (Left-90) --- ---- 1 2.4 0.38 0.35 Insect Screen (default) 5 -- .32.30 Window E Wag (Left-90) 4.0 5.5 1 22.0 0.32 0.30 Insect Screen (default) 6 ---- .30.17 Window E Wall (Left-90) - - ---- 1 2.4 0.30 0.17 Insect Screen (default) 34 ---- .30.17 Window S Wall (Back-180) 2.0 5.5 1 11.0 0.30 0.17 Insect Screen (default) 35 ---- .30.17 Window S Wall (Back-180) 1.5 3.0 1 4.5 0.30 0.17 Insect Screen (default) 36 ---- .30.17 Window S Wall (Back-180) 5.0 5.5 1 27.5 0.30 0.17 Insect Screen (default) 17 ---- .30.17 Window S Wall (Back-180) 1.5 3.0 1 4.5 0.30 0.17 Insect Screen (default) 16 ---- .30.17 Window S Wall (Back-180) 2.5 5.5 1.004 13.8 0.30 0.17 Insect Screen (default) 15 ---- .30.17 Window S Wall (Back-180) 2.5 5.5 1.004 13.8 0.30 0.17 Insect Screen (default) 14 ---- .30.17 Window S Wall (Back-180) 1.5 3.0 3.067 13.8 0.30 0.17 Insect Screen (default) 13 ---- .30.17 Window S Wall (Back-180) 3.0 5.5 0.273 4.5 0.30 0.17 Insect Screen (default) 19 ---- .30.17 Window S Wall (Back-180) 3.0 5.5 1 16.5 0.30 0.17 Insect Screen (default) 18 ---- .30.17 Window S Wall (Back-180) 3.0 5.5 1 16.5 0.30 0.17 Insect Screen (default) 8 -- .38.35 Window S Wall (Back-180) 3.0 4. 22 24.0 0.38 0.35 Insect Screen (default) 28 ---- .32.30 Window W Wall (Right-270) 12.0 8.0 1 96.0 0.32 0.30 Insect Screen (default) 27 ---- .32.30 Window W Wall (Right-270) 12.0 8.0 1 96.0 0.32 0.30 Insect Screen (default) 29 ---- .32.30 Window W Wall (Right-270) 17.3 12.0 1 1.002 208.0 0.32 0.30 Insect Screen (default) Registration Number: 218-P010262971C-000-000-0000000-0000 Registration Date(fime: 2018-10-05 10:33:18 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:22:35 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 191 Main w casita Residence Calculation Date/Time: 10:21, Fri, Oct 05, 2018 CF1 R-PRF-01 Page 7 of 12 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Main-Plan 25-Pekerek-18.ribd16x 7 ---- .32.30 Window W Wall (Right-270) 6.0 8.0 1 1 1 48.0 1 0.32 1 0.30 1 Insect Screen (default) OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Door E Wall 24.0 0.50 � CaICERTS, Inc. Registration Number: 218-Po10262971C-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:33:18 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:22:35 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 191 Main w casita Residence Calculation Date/Time: 10:21, Fri, Oct 05, 2018 CF1 R-PRF-01 Page 8 of 12 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Main-Plan 25-Pekerek-18.ribd16x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up _= 1.5x3---- .32.30 8 0.1 8 8 0 0 0 0 0 0 0 0 0 21 ---- .32.30 8 0.1 8 8 0 0 0 0 0 0 0 0 0 22 ---- .32.30 8 0.1 8 8 0 0 0 0 0 0 0 0 0 =6x8 38---- .32.30 8 0.1 8 8 0 0 0 0 0 0 0 0 0 30 ---- .32.30 8 0.1 8 8 0 0 0 0 0 0 0 0 0 ===1.5x3 ---- .38.35 8 0.1 8 8 0 0 0 0 0 0 0 0 0 31 ---- .30.17 8 0.1 8 8 0 0 0 0 0 0 0 0 0 1 --- .30.17 8 0.1 8 8 0 0 0 0 0 0 0 0 0 2 ---- .30.17 8 0.1 8 8 0 0 0 0 0 0 0 0 0 24 ---- .32.30 10 0.1 10 10 0 0 0 0 0 0 0 0 0 25 ---- .32.30 10 0.1 10 10 0 0 0 0 0 0 0 0 0 5 ---- .32.30 10 0.1 10 10 0 0 0 0 0 0 0 0 0 34 ---- .30.17 10 0.1 10 10 0 0 0 0 0 0 0 0 0 35 ---- .30.17 10 0.1 10 10 0 0 0 0 0 0 0 0 0 36 ---- .30.17 10 0.1 10 10 0 0 0 0 0 0 0 0 0 17 ---- .30.17 10 0.1 10 10 0 0 0 0 0 0 0 0 0 16 ---- .30.17 10 0.1 10 10 0 0 0 0 0 0 0 0 0 15 ---- .30.17 10 0.1 10 10 0 0 0 0 0 0 0 0 0 14 ---- .30.17 10 0.1 10 10 0 0 0 0 0 0 0 0 0 13--.30.17 10 0.1 10 10 0 0 0 0 0 0 0 0 0 19 ---- .30.17 10 0.1 10 10 0 0 0 0 0 0 0 0 0 18 ---- .30.17 10 0.1 10 10 0 0 0 0 0 0 0 0 0 8— .38.35 10 0.1 10 10 0 0 0 0 0 0 0 0 0 28 ---- .32.30 10 0.1 10 10 0 0 0 0 0 0 0 0 0 27 --- .32.30 10 0.1 10 10 0 0 0 0 0 0 0 0 0 29 ---- .32.30 18 0.1 18 18 0 0 0 0 0 0 0 0 0 7---- .32.30 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Registration Number: 218-P010262971C-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:33:18 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:22:35 CF1 R-PRF-01 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 191 Main w casita Residence Calculation Date/Time: 10:21, Fri, Oct 05, 2018 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Main-Plan 25-Pekerek-1 8.ribd 1 6x Page 9 of 12 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Around Roof Joists: R-6.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofresidence Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.059 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 R-21 Wall (W.21.2x6 16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Cavity / Frame: R-13 / 2x4 R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 Other Side Finish: Gypsum Board SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Covered Slab ex residence 4502 266 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Central Parallel Piping DHW Heater 1 (2) 2 .0% Registration Number: 218-P010262971C-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:33:18 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:22:35 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 191 Main w casita Residence Calculation Date/Time: 10:21, Fri, Oct 05, 2018 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Main-Plan 25-Pekerek-1 8.ribd 1 6x CF1 R-PRF-01 Page 10 of 12 WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Input Rating / Tank Standby Heater Tank Uniform Energy Pilot / Insulation Loss / First Hour NEEA Heat Pump Tank Location Element Number Volume Factor / Energy Thermal R-value Recovery Rating / Brand / Model / or Ambient Name Type Tank Type of Units (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Other Condition DHW Heater 1 Gas Large Storage 2 75 0.76 TE 76,000 Btu/hr R-0/R-0 0.02 n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC1 Heat Pump Heating and Cooling System Heat Pump System 1 Heat Pump System 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 1 SplitHeatPump 4 8.2 34250 20550 15 12.2 Not Zonal Single Speed Heat Pump System 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Heat Pump System 1-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handier Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a Registration Number: 218-P010262971C-000-000-0000000-0000 Registration DatefTime: 2018-10-05 10:33:18 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:22:35 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 191 Main w casita Residence Calculation Date/Time: 10:21, Fri, Oct 05, 2018 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Main-Plan 25-Pekerek-18.ribdl6x CF1 R-PRF-01 Page 11 of 12 HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 75 0.25 Default 0 Required � CaICERTS,I 11 F R • HERS PROV Registration Number: 218-P010262971C-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:33:18 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-05 10:22:35 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 191 Main w casita Residence Calculation Date/Time: 10:21, Fri, Oct 05, 2018 Calculation Description: Title 24 Analysis Input File Name: Andalusia -Lot 191-Main-Plan 25-Pekerek-18.ribd16x CF1 R-PRF-01 Page 12 of 12 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete Documentation Author Name: Documentation Author Signature: Tim Scott ;�'s _:5�e Company: Signature Date: Scott Design and Title 24, Inc. 2018-10-05 10:33:18 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: 7A'w5aoi' Tim Scott Company: Date Signed: Scott Design and Title 24, Inc. 2018-10-05 10:33:18 Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. 00 Easy to Verify at CaICERTS.com Registration Number: 218-Po10262971C-000-000-0000000-0000 Registration Date/Time: 2018-10-05 10:33:18 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 HERS Provider: CaICERTS inc. Report Generated at: 2018-10-05 10:22:35