Loading...
BMCH2019-006578-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T4hf 4 sq� Railtroi DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: IE INC 31225 LA BAYA WESTLAKE VILLAGE, CA 91362 MECHANICAL/ BMCH2O19-0065 81640 RUSTIC CANYON DR 764540002 HENRY / INSTALL NEW (1)16SEER/8AFUE SPLIT SYSTEM IN GARAGE $12,900.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C36, C10.C20 License No.: 765074 Date: Z T4' I Contractor:�� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. . B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: Date: 2/28/2019 Owner: HENRY, GREGORY P & PATRICIA G 81640 RUSTIC CANYON DU LA QUINTA, CA 92253 Ga m rn -::� m CD Contractor: IV A R S AMERICAN RESIDEN�IAtYER;5 ❑ 965 RIDGE LAKE BLVD. # z o MEMPHIS, TN 38120 n 39 (951)276-9744 M Llc. No.: 765074 z WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance or the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: LIBERTY INSURANCE CORPORATION Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: ?4 I ri Applicant' ` 4 -- l ----- — WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE 15 UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to .he conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose 'equest and for whose benefit work is performed under or pursuant to any permit ssued as a result of this application , the owner, and the applicant, each agrees to, and ;hall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and ?mployees for any act or omission related to the work being performed under or 'ollowing issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is iot commenced within 180 days from date of issuance of such permit, or cessation of Nork for 180 days will subject permit to cancellation. certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building :onstruction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. )ate: Zc Signature (Applicant or ,Date: 2/28/2019 Application Number: BMCH2019-0065 Property Address: 81640 RUSTIC CANYON DR APN: 764540002 Application Description: HENRY / INSTALL NEW (1)16SEER/8AFUE SPLIT SYSTEM IN GARAGE Property Zoning: Application Valuation: $12,900.00 Applicant: IE INC 31225 LA BAYA WESTLAKE VILLAGE, CA 91362 Owner: HENRY, GREGORY P & PATRICIA G 81640 RUSTIC CANYON DR LA QUINTA, CA 92253 Contractor: A R S AMERICAN RESIDENTIAL SERVICES OF C 965 RIDGE LAKE BLVD. #201 MEMPHIS, TN 38120 (951)276-9744 Llc. No.: 765074 Detail: ADD (1)HVAC 16SEER/8AFUE SPLIT SYSTEM IN GARAGE. SPILT SYSTEM IS NOT TITLE 24 COMPLIANT, NOT TO BE USED AS HABITABLE SPACE. REPLACE (21) RUNS OF DUCT WORK FOR (2)EXISTING UNITS. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT HVAC CHANGEOUT - REPAIR/ALTERATION 101-0000-42402 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT HVAC CHANGEOUT - REPAIR/ALTERATION PC 101-0000-42600 0 $10.68 Total Paid for CHANGEOUT: $37.36 DESCRIPTION ACCOUNT CITY AMOUNT AIR HANDLER 101-0000-42402 0 $40.02 DESCRIPTION ACCOUNT QTY AMOUNT AIR HANDLER PC 101-0000-42600 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE 101-0000-42402 0 $40.02 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE PC 101-0000-42600 0 $26.68 Total Paid for MECHANICAL: $120.06 DESCRIPTION ACCOUNT CITY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $101.40 Total Paid for PERMIT ISSUANCE: $101.40 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 TOTALS: CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) Project Name: HENRY, GREG I Date Prepared: CF1R-ALT-02-E (Page 1 of 4) 2018-12-03 A. General Information CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 Project Name HENRY, GREG 02 Date Prepared 2019-02-28 03 Project Location 81640 RUSTIC CANYON DR. 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name HENRY,GREG 07 Zip Code 92253 08 Dwelling Unit Conditioned 2520 Floor Area (ft) Number of Space 09 Climate Zone 15 10 Conditioning (SC) Systems in 3 this Dwelling Unit: B. Space Conditioning (SC) System Information 01 02 03 04 05 06 07 08 09 10 Is the SC Installing a SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 Location 1 840 Yes No No Yes No No Extension of existing duct system System 2 Location 2 840 Yes No No Yes No No Extension of existing duct system Entirely new or System 3 Location 3 840 No No Yes No No Yes complete replacement space conditioning system Registration Number: 419-A020019343A-000-000-0000000-0000 Registration Date/Time: 2019-02-28 12:41:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-02-28 12:41:10 Schama Varainn- rPv 7nlRn4?F CERTIFICATE OF COMPLIANCE CHR-ALT 02-E Alterations to Space Conditioning Systems (formerly CF-lR-ALT HVAC) (Page 2 of 4) C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)1Diib) 01 02 System Identification or New Duct R-Value Name System 1 R-8 System 2 R-8 Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16) CF2R and MR-MCH-20-1-1 Duct Leakage Test - Leakage rate compliance: <= 15%, or <= 10% leakage to outside, or seal all accessible leaks Exceptions: Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 duct leakage testing requirements D. Altered Space Conditioning System (Sections 150.2(b)lE and F) This section does not apply to this project. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)1E, F) This section does not apply to this project. Registration Number: 419-A020019343A-000-000-0000000-0000 Registration Date/Time: 2019-02-28 12:41:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-02-28 12:41:10 Srhpma Varcinn: rpv ?ol Rn4?6 CERTIFICATE OF COMPLIANCE CF111-ALT 02-E Alterations to Space Conditioning Systems (formerly CF-lR-ALT HVAC) (Page 3 of 4) F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) O1 02 03 04 05 06 07 08 09 10 11 Heating Cooling System Heating Minimum Cooling Minimum Required Identification or Heating System Altered Heating Efficiency Efficiency Cooling Altered Cooling Efficiency Efficiency Thermostat New Duct Name Type Component Type Value System Type Component Type Value Type R-Value Heating Seasonal This field System 3 Ductless All new heating Performanc 8 Ductless All new cooling SEER 16 SetbackTher or section mini -split HP components e Factor mini -split HP components mostat is not (HSPF) applicable Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16) CF211 and CF3R-MCH-20-H Duct Leakage Test required - Leakage rate compliance: <= 5%. CF2R and CF3R-MCH-22 Fan Efficacy CF2R and CF3R-MCH-23 Airflow Rate Verification Compliance: Fan Efficacy <= 0.58 W per cfm and System Airflow >= 350 cfm per ton. Alternative Compliance: CF2R and CF3R-MCH-28 Return Duct Design verification is an alternative to MCH-22 and MCH-23 verification. CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). Exceptions: Heating -only systems are exempt from the 0.58 W per cfm and 350 cfm per ton requirements. Note: An "entirely new or replacement duct system" means at least 75% of the duct system is new duct material, and up to 25% may consist of reused parts from the dwelling unit's existing duct system (e.g., registers, grilles, boots, air handler, coil, plenums, duct material) if the reused parts are accessible and can be sealed to prevent leakage Registration Number: 419-A020019343A-000-000-0000000-0000 Registration Date/Time: 2019-02-28 12:41:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-02-28 12:41:10 irhpma Vprcinn- rpv 701 Rn426 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 4 of 4) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Jo Anne Orona J&An*,L&0rona• Company: Signature Date I Permit E Raters 2019-02-28 Address: CEA/ HERS Certification Identification (if applicable): 31225 La Baya Drive City/State/Zip: Phone: Westlake Village CA 91362 818-735-7876 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature: Christina Calhoun ChrLsMna,Ca.11wuvv Company: Date Signed: Rightime Home Services 2019-02-28 Address: License: 965 Ridge lake Blvd, Suite 201 765074 City/State/Zip: Phone: Memphis TN 38120 951-276-9744 Digitally signed by CHEERS"". This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 419-A020019343A-000-000-0000000-0000 Registration Date/Time: 2019-02-28 12:41:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-02-28 12:41:10 Schema VPrcinn: rav 2f11 R0426 FPERMIT# — G PO # eh, D tii H RT — PLAN LOCATION: Project Address: C, Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: Or Cl car e- Applicant Name: &-eV[hG , ..CeC $ Z1 Gw' a far Address: 31 Z?-5 U City, ST, Zip: ",s �c�k e V�11 rx A CA 916 2- Telephone: Email: Valuation of Project r Name:._ � ' New SFD Construction: _ .�;rv�ce FAddress: u p- Lc L , Zgl Conditioned SpaceSF ,,p em �.� s YN $ Z0 nSF Garage g Telephone: qr> l _ Z--) I _ Q Patio/Porch SF Email: Fire Sprinklers SF State Lic: 2Iv50 74 City Bus Lic: Arch/Eng Name: Construction Type: Occupancy: P Y: Address: Grading: City, St, Zip Telephone: Bedrooms: TSories: # Units: Email: State Lic: City Bus Lic: } Property Owner's Name: New Commercial / Tenant Improvements: Address:�� Total Building SF City, ST, Zipf r-. a C 4, y Z25 3 Construction Type: Occupancy: Telephone, 5,2- 5(v— 2 17p Email: 78495 CALLE TAMPICO J LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY z February 28, 2019 City of La Quinta The garage of our residence at 81640 Rustic Canyon Drive, in the City of La Quinta has insulated walls, ceiling and garage door. The walls and ceiling are covered with dry wall. We are not trying to be Title 24 compliant and the garage will only be used to store our vehicles. Sincer,etk, ureg rrenry Home Owner Ic PL CA to I�sse�les5 A Sys��� ro. 5c am so CC" CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCT ON DATEP�{�yLBY