BRES2018-008778-495 CALLE TAM PICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: BRIAN FERGUSON 52293 EISENHOWER LA QUINTA, CA 92253 Tur°d lwQU&rw DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT BUILDING RESIDENTIAL/REMODEL BRES2018-0087 52293 EISENHOWER DR 773265013 ZARDENETA / REMODEL $18,000.00 :e FEB 1 2019 D CITY OF LA QUINTA DESIGN & DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.::CONV:140528101254091610 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a I,iper sub'eCts the applicant to a civil penalty of not more than five hundred dollars , as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold with, one year of completion, the owner -builder will have the burden of proving that �# 5e did not build or Improve for the purpose of sale:). +_], as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves hereon, and who contracts for the projects with a contractor(s) licensed pursuant to tractors' State License Law.). I,CL) I am exempt under sec. . B.&P.C. for this reason Date: _44 ` CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/14/2019 Owner: BRIAN FERGUSON 52293 EISENHOWER DRIVE LA QUINTA, CA 92253 Contractor: BRIAN FERGUSON 81162 FRED WARING DRIVE #104 INDIO, CA 92201 Llc. No.::CONV:140528101254091610 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is Issued. My workers' compensation insurance carrier and policy number are: Carriz,rVl Policy Number: _ pwiI certify that In the performance of the work for which this permit Is issued, I OMIAnot employ any person In any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Sect lon 37 of the Labor Code, I shall forthwith comply ith asepr❑vls o�r - Date: [ (� r/ . Applicant: + WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentionedMSIgnature yforInspection purposes. Dater 44 (Applicant or Agent): Date: 2/14/2019 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: Applicant: BRIAN FERGUSON 52293 EISENHOWER LA QUINTA, CA 92253 BRES2018-0087 52293 EISENHOWER DR 773265013 ZARDENETA / REMODEL $18,000.00 Owner: BRIAN FERGUSON 52293 EISENHOWER DRIVE LA QUINTA, CA 92253 Contractor: BRIAN FERGUSON 81162 FRED WARING DRIVE #104 INDIO, CA 92201 Llc. No.::CONV:140528101254091610 Detail: ZARDENETA / 245 SF ADDITION + INTERIOR REMODEL TO EXISTING 1,115 S.F. HOME, RESULTING IN A TOTAL OF 1,360 SF. ENCLOSE 49 SF PATIO UNDER EXISTING ROOF AND CONVERT TO LIVING SPACE. REMODEL KITCHEN AND BEDROOMS.THIS PERMIT DOES NOT INCLUDE THE REPLACEMENT OF THE EXISTING HVAC EQUIPMENT OR ELECTRICAL SERVICE PANEL. 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $67.10 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $18.72 DESCRIPTION ACCOUNT CITY AMOUNT ADDITION, FIRST 100 SF 101-0000-42400 0 $131.07 DESCRIPTION ACCOUNT CITY AMOUNT ADDITION, FIRST 100 SF PC 101-0000-42600 0 $184.13 Total Paid for ADDITION: $401.02 DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($119.50) DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - ESGIL PLANS EXAMINER 101-0000-42600 3 $119.50 DESCRIPTION ACCOUNT CITY AMOUNT HOURLY CHARGE - ESGIL PLANS EXAMINER 101-0000-42600 0 $3.00 Total Paid for BLDG CITY STAFF - PER HOUR: $3.00 DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $39.01 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE 101-0000-42402 0 $39.01 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE PC 101-0000-42600 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN 101-0000-42402 0 $13.00 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN PC 101-0000-42600 0 $5.20 Total Paid for MECHANICAL: $148.24 DESCRIPTION ACCOUNT QTY AMOUNT PATIO COVER, DESIGNED 101-0000-42404 0 $143.56 DESCRIPTION ACCOUNT QTY AMOUNT PATIO COVER, DESIGNED PC 101-0000-42600 0 $181.01 Total Paid for PATIO COVER / COVERED PORCH / LATTICE: $324.57 DESCRIPTION ACCOUNT QTY AMOUNT PLAN CHECK DEPOSIT - ADDITION/REMODEL 101-0000-42600 1 $125.00 Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $39.00 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $39.00 Total Paid for PLUMBING FEES: $78.00 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $70.23 DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $56.16 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 100 SF 101-0000-42400 0 $53.05 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 0 $145.12 Total Paid for REMODEL: $324.56 DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($0.50) DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $0.50 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.00 DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($5.00) DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $0.00 DESCRIPTION ACCOUNT QTY AMOUNT DOOR/WINDOW, RETRO/REPAIR, FIRST 7 101-0000-42400 0 $65.54 DESCRIPTION ACCOUNT CITY AMOUNT DOOR/WINDOW, RETRO/REPAIR, FIRST 7 PC 101-0000-42600 0 $63.98 Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $129.52 �+ • W W PERMIT 2o IT- - 00 ' PLAN LOCATION: Project Address: �Z2 /S �rl` j,J't'� t� Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: a(Ad L c, Applicant Name: __fi Address: 2 �-, ,1 42 City, ST, Zip: `-4r- Telephone: ` &0 Email: f 2'a f C� /� ��� ` �sJ ,I � �yl Valuation of Project $ �� LTV�� Contractor Name: Dv� t j�4� �j�J t L�� (� New SFD Construction: Address: Conditioned Space _ _ SF City, St, Zip Garage SF Telephone: Patio/Porch SF Email: Fire Sprinklers SF State Lic: City Bus Lic: Arch/Eng Name: Construction Type: Occupancy: Address: Grading: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: Fur26, usp/v hierA o New Commercial / Tenant Improvements: Address: Total Building SF City, ST, Zip Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QU I NTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal Req'd -Rec'd Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License Tjhf 4.fwa" P.O. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALL-FORNIA 92253 BUILDING & SAFETY DEPARTMENT - PROPERTY OWNER'S PACKAGE (760)777-7012 FAX (760) 777-701 1 Disclosures & Forms for Owner -Builders Applying for Construction Permits IMPORTANT! NOTICE TO PROPERTY OWNER Dear Property Owner: An application for a building permit has been submitted in our name listing > . Y g yourself as the builder of the roperty improvements specified at • :1; �-, y� �-'• We are providing p g you with anOwner-Bur der Acknowledgment an Information Verification Forrr► c make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION DIRECTIONS: Read and initial each statement below to signOY you understand or ver fy this information. I understand a Frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder" bu ukg permit that erroneously implies that theproperty owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held Iiable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property, My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. C62. I understand buildingpermits are not required to be signed b p q g y property owners unless they are responsible for the , ruction and are not hiring a licensed Contractor to assume this responsibility. r3. I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect m elf from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. 4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on is and contracts. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value ai?yriy construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. 6. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal g ernment, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential struc ures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed su ontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. 8. I understand as an Owner -Builder if I sell the property for which this permit is.issued, I may be held liable for any fi' ncial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Slice, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1- 800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. 10. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the legally� and panciall xespo ible for proposed construction activity at the following address: 4_ 1. 1 agree that, as the parry legally and financially responsible for this proposed construction activity, I will abide by all ap able laws and requirements that govem Owner -Builders as well as employers. 4,1-2-:-1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. -It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature, f Y Signature of property owner L'' f Date: Note: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGENT TO ACTON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work):. Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: Tel No I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification acceptable to the agency is required to be presented when the permit is issued to verb the property owner's signature. Property Owner's Signature: Date: Twyl 4 4a" P.O. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT PROPERTY OWNER'S PACKAGE (760) 7 77 -7012 FAX (760) 777-7011 Disclosures & Forms for Owner -Builders Applying for Construction Permits IMPORTANT! NOTICE TO PROPERTY OWNER Dear Property Owner: An application for a build�permi i b n s bmitted in yo�r name listing urs s the builde of he prvpe improvements specified at j���G� (� We are providing you with an Owner -Builder AciaiowLedgme tan Info Verification Form to make you aware of yopr L�pb responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION DIRECTIONS: Read and initial each statement below to signs you understand or verb this information. �rlI understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the lirnits of my insurance coverage for injuries to workers on mVLK2, y property. I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. yI understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect thyself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my 0I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on perZ�', nd contracts. + L . understand if employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars (S500), including labor and materials, I may be considered an "employer" under state and federal law. K5. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal overnment, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. W 8. I understand as an Owner -Builder if I sell the property for which this permit is issued, ! may be held liable for any [financial or personal injuries sustained b an subsequent owner(s) that result from any latent construction defects in the Pe J Y Y �1 workmanship or materials. )/ 4. 1 understand i may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1- 800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. 1 lQ, I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the party legally and financially responsible f proposed construe n activity at the following address: _ �-� YLS1. I agree that, as the partylegally a'L' financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner -Builders as well as emptoyers. klia12.I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I Je �' provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with p someone who does not have a license, the Contractors' State License Board maybe unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. N : A copy of the property owner's driver's license, form notarization, or other verification acceptable to the agency is ired to be presented when the permit is issued to verify the property owner's signature. INC— c� / ! �� C , Signature of property owner Date: 7 `-(�/ Note: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: Tel No I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: CITY OF LA QUINTA SUB-CONT ACTO LIST JOB ADDRESS_ .�Z Z`l l SE�1 fnw�l� Dy2) VZ PERMIT NUMBER�9�� --cC7 OWNER _ a BUILDER +� W►JE'� 3y I -D62 This form shall -be posted on the job with the Building Inspection Card at all times in a conspiquous place. Only persons appearing on this list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance .,f k *.I d;- .. . ;t F—r oo k nnnlir•nhln trarla all infnrmatinn roninnCtorl h0lnlA/ mimt hi-_ rmmnlntari by nnnlir.ant- "On File" is not an acceptable response. Trade.-/.Glass.:i#ication. Contract r •., St.a.te. C.:ontracta.r'..s L.iCenSe Workers Compensation Insurance City Busine.ss,Lic.e.rkse Company Name Classification License Number Exp. Date Carrier Name Policy Number Exp. Date License Number Exp. Date (e.g. A, B, C-8) (xxxxxx) (xx/xx/xx) (e.g. State Fund, CalComp) (Format Varies) (xx/xx/xx) (xxxx) (xx/xx/xx) EARTHWORK (G-12). CONCRETE (.C=$.) .FRAMING (C-5) . STRU.CT. STEEL (C.=51.) MASONRY (.0 29) PLUMBING (C-3:6) i :LATH, PLASTER (C-3.5) DRYWALL (C-9): ,I-IVAC (C-20) ELECTRICAL (C-10.) SHEET METAL.(C-43) -FLOORING, (C-15) .GLAZING (C-1:7) INSULATION (C-2) SEWAGE DISP..(C-42) PAINTING (C-33) CERAMIC TILE (C-54) CABINETS (:C % FENCING (C43) LANDSCAPING (C-27) Pool- (C-53) . CERTIFICATE OF COMPLIANCE ��►���° s Desert Sands Unified School District oy c0. 47950 Dune Palms Road '-"A "^°�ryF:r RIWDIi[1 hDUN � G }" INWAN WELLS y )ate: 1/28/2019 La Quinta, CA 92253 °� P""���A` aY ��LAr (7lDT� yn, Vo.: 19-01239-1 (760)771-8515 )wner: Brian Ferguson Email: address: 52293 Eisenhower Jurisdiction: La Quinta -ity: La Quinta Tract #: hype: Residential Addition < 500 Sq ft -ot # Street No. Street Name Sq. Feet APN Permit No. 52293 Eisenhower 245 773-265-013 :omments: kt the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions ender 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement nobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less Exempt Fhis certifies that school facility fess imposed pursuant to :ducation Code Section 17620 and Government Code 65995 Et Seq. n the amount of $0.00 X 245 S.F. or $0.00 have been paid for the property listed above and that building permits end/or Certificates of Occupancy for this square footage in the proposed project may now be issued. :ees Paid By: Exempt / Philip Moore Bank Name/Recipient of Certificate 3y Scott L. Bailey Superintendent Fee Collected/ Exempted by: Rodney Slagle Check No.: Telephone: 951-377-6262 Funding: Residential Certificate Fees Due: $0.00 Original Paymert(s) Rec'd: $0.00 l New Payment Rec'd: $0.00 I Over/Under: $0.00 J 40TICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or ether payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on vhich those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. V EsGil A SAFEhuilt'Company DATE: 2/ 12/2019 D 6PPLICANT .fURIS. JURISDICTION: City of La Quinta PLAN CHECK #.: BRES2018-0087 SET: II PROJECT ADDRESS: 52293 Eisenhower PROJECT NAME: Residential Addition for Ferguson Residence — Structural Only ❑ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ® The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ❑ The applicant's copy of the check list has been sent to: ® EsGil staff did not advise the applicant that the plan check has been completed. ❑ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: Email: Mail Telephone Fax 41 ®rson ® REMARKS: Person responsible for plan preparation to add note clouded in red on sheet S1.0 to the set of plans held at the city to match the plan set being approved. By: Rich Moreno EsGil 2/4/2019 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 BUILDING ENERGY ANALYSIS REPORT PROJECT: SINGLE HOUSE ADDITION 52293 EISENHOWER LA QUINTA, CA 92253 Project Designer: Report Prepared by: PERFECT DESIGN & INVESTMENT CITY OF LA QUANTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DAT4J4J-A,01q BY Job Number: A18-1318 Date: 2/16/2018 RECEIVED MAR 0 7 2018 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the Calirornia Energy Commission for use with both the Residential and Nonresidential 201t G1"rG1!J_efpW1q4;tff Standards. This program developed by EnergySoft Software — www.energysoit:Av UNITY DEVELOPMENT Is � TABLE OF CONTENTS Cover Page Table of Contents 1 Form CF-1 R-PRF-01-E Certificate of Compliance 2 Form RMS-1 Residential Measures Summary 3 Form MF-1 R Mandatory Measures Summary 10 HVAC System Heating and Cooling Loads Summary Zone Load Summary 11 Room Load Summary 16 Room Heating Peak Loads 17 Room Cooling Peak Loads 18 20 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPL aNCE METHOD CF1 R-PRF-01 Project Name: SINGLE HOUSE ADDITION Calculation Date/Time: 12:22, Fri, Feb 16, 2018 Page 1 of 7 Calculation Description: Title 24 Analysis Input File Name: tmpCOC1.tmp.xml GENERAL INFORMATION 01 Project Name SINGLE HOUSE ADDITION 02 Calculation Description Title 24 Analysis 03 Project Location 52293 EISENHOWER 04 City LA QUINTA 05 Standards Version Compliance 2017 06 Zip Code 92253 08 07 Compliance Manager Version BEMCmpMgr 2016.3.0 (1016 SP2) Climate Zone CZ15 10 09 Software Version EnergyPro 72 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Addi?ior. and/or Alteration 13 14 Number of Dwelling Units 1 Total Cond. Floor Area (ft2) 1360.5 15 Number of Zones 2 16 Slab Area (ft2) 1360.5 17 Number of Stories 1 16 Addition Cond. Floor Area (ft) 245.5 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 245.5 21 Glazing Percentage (%) 12.0% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building incorporates one or more Special Features shoe below AERGY USE SUMMARY 04 05 Energy Use (kTDV/ft2-yr) Standard Design 06 Proposed Design 07 08 Compliance Margin p Space Heating 13AI g Percent Improvement Space Cooling 429.15 13.24 0.17 1.3% lAQ Ventilation 0.00 412.11 17.04 4.0% Water Heating 16.75 0.00 0.00 0.0% Photovoltaic Offset 16.75 0.00 0.0% -- Compliance Energy Total 459.31 0.00 0.00 442.10 17.21 3.7% RE4UIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled e; rgy performance for this computer analysis. • New ductwork added is less than 40 ft. in length Registration Number: 418-P010009727A-000-000-0000000-0000 Registration Date/Time: 02116/2018 12:31 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02082018-1016 SP2 HERS Provider: CHEERS Report Generated at: 2018-02-1612:23:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPL INCE METHOD Project Name: SINGLE HOUSE ADDITION Calculation Date/Time: 12:22, Fri, Feb 16, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpCOC1 tmp.xmi CF1 R-PRF-01 Page 2 of 7 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HER. Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building4evel Verifications: • --None-- o Coling System Verifications: • -- None — HVAC Distribution System Verifications: • --None -- Domestic Hot Water System Verifications: • —None — BUILDING - FEATURES INFORMATION 01 02 03 Project Name Conditioned Floor Area (ft2) Number of Dwell: Units SINGLE HOUSE ADDITION 1360.5 1 ZONE INFORMATION 01 02 03 Zone Name Zone Type HVAC System ADDITION AREA EXISTING AREA Conditioned Conditioned WHOLE HO: WHOLE HOi 04 05 06 07 Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 3 2 0 1 04 05 06 07 Vame Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 3Ei 3Ell 245.5 1115 8 1 8 DHW Sys 1 DHW Sys 1 n/a n/a Registration Number: 418-P010009727A-000-000-OD00000-0000 Registrati, .i DatelTime: 02/16/2018 12:31 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Vc, sion - CF1 R-02082018-1016 SP2 Report Generated at: 2018-02-16 12:23:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPI -,NCE METHOD Project Name: SINGLE HOUSE ADDITION Calculation Datemme: 12:22, Fri, Feb 16, 2018 Calculation Description: Title 24 Analysis OPAQUE SURFACES 01 02 03 Name Zone Constructior WEST WALL ADDITION AREA R-15 Wall EAST WALL ADDITION AREA R-15 Wall SOUTH WALL ADDITION AREA R-15 Wall Wall to Addition ADDITION AREA»EXISTING AREA R-15 Walll New Roof ADDITION AREA R-38 Roof Atti WEST WALL 2 EXISTING AREA Default Wall Prior' EAST WALL 2 EXISTING AREA Default Wall Prior, NORTH WALL EXISTING AREA Default Wall Prior SOUTH WALL 2 EXISTING AREA Default Wall Prior Wall to Addition 2 EXISTING AREA»ADDITION AREA R-15 Wall1 EXISTING ROOF EXISTING AREA Default Roof 1950 ATTIC 01 02 03 Name Construction Type Attic ADDITION AREA Attic RoofADDITION AREA Ventilated Attic EXISTING AREA Attic RoofEXISTING AREA Ventilated FENESTRATION / GLAZING 01 02 03 Name Surface (Orientation -Azimuth) Width (ft) WINDOWS WEST WALL (Back-270) — WINDOWS 2 WEST WALL 2 (Back-270) ---- WINDOWS 3 EAST WALL 2 (Front-90) — WINDOWS 4 NORTH WALL (Right-0) — WINDOWS 5 SOUTH WALL 2 (Left-180) Input File Name: tmpC0C1.tmp.xml CFI R-PRF-01 Page 3 of 7 04 05 06 07 08 09 10 Azimuth Orientation Gross Area (ft) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition 270 Back 116 53.6 90 New n/a 90 Front 88 0 90 New n/a 180 Left 112 0 90 New n/a 352 0 New n/a 245.5 New n/a i0 t 270 Back 220 44 90 Existing No i0 t 90 Front 248 20 90 Existing No i0 It 0 Right 280 28 90 Existing No ;0 t 180 Left 1 168 17.5 90 Existing No 352 0 New n/a Pre1 1115 Existing No 04 05 06 07 08 09 10 Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition 4 0.1 0.85 Yes No New No 4 0.1 0.85 No No Existing No 04 05 06 07 08 09 10 11 =fight (ft) Multiplier Area (ft)Existing U-factor SHGC Exterior Shading Status Verified Condition -- 1 53.6 0.32 0.25 Insect Screen (default) New n/a - 1 1 44.0 20.0 1.19 1.19 0.83 0.83 Insect Screen (default) Insect Screen (default) Existing Existing No No — 1 28.0 1.19 0.83 Insect Screen (default) Existing No — 1 17.5 1.19 0.83 Insect Screen (default) Existing No Registration Number: 418-P010009727A-000-000-0000000-0000 Registration Daterrime: 02/16/2018 12:31 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance ReportVc sion - CF1 R-02082018-1016 SP2 Report Generated at: 2018-02-16 12:23:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPL' kNCE METHOD Project Name: SINGLE HOUSE ADDITION Calculation Description: Title 24 Analysis OPAQUE SURFACE CONSTRUCTIONS 01 02 03 Construction Name Surface Type Construction Type Attic RoofADDITION AREA Attic Roofs Wood Framed Ceiling 2x4 Tot R-38 Roof Attic Ceilings (below attic) Wood Framed Ceiling R-15 Wall Exterior Walls Wood Framed Wall R-15 Wall1 Interior Walls Wood Framed Wall Attic RoofEXISTING AREA Attic Roofs Wood Framed Ceiling 2x4 To' Default Roof 1950 to Pre Ceilings (below attic) Wood Framed Ceiling Default Wall Prior 1950 t Exterior Walls Wood Framed Wall SLAB FLOORS 01 Name 02 Zone 03 Area (fl Covered Slab ADDITION AREA 245 Covered Slab 2 EXISTING AREA 1115 BUILDING ENVELOPE - HERS VERIFICATION 01 02 Calculation Date/Time: 12:22, Fri, Feb 16, 2018 input File Name: tmpC0C1.tmp.xm1 CF1 R-PRF-01 Page 4 of 7 04 05 06 07 Total Cavity Winter Design Framing R-value U-factor Assembly Layers • Cavity/Frame: no insul. /2x4 Top Chrd 3hord of Roof Truss @ 24 Roof Deck., Wood Siding/sheathing/decking in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • inside Finish: Gypsum Board • Cavity/Frame: R-9.1 /2x4 x4 @ 24 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • inside Finish: Gypsum Board • Cavity / Frame: R-15 / 2x4 x4 @ 16 in. O.C. R 15 0.095 Exterior Finish: 3 Coat Stucco • inside Finish: Gypsum Board • Cavity/Frame: R-15/2x4 x4 @ 16 in. O.C. R 15 0.086 Other Side Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 Top Chrd :fiord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • inside Finish: Gypsum Board 2x4 @ 16 in. O.C. none 0.472 Cavity/Frame: no insul. /2x4 • Inside Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 ?x4 @ 16 in. O.C. none 0.361 Exterior Finish: 3 Coat Stucco 04 Perimeter (ft) 05 Edge Insul. R-value 06 Carpeted Fraction 07 Heated 08 Status 09 Verified Existing Condition 39.5 None 0.8 No New No 114.5 None 0.8 No Existing No 03 Quality Insulation Installation (CAI) Quality Installation of Spi . y Foam Insulation Building Envelope Air Leakage Not Required Not Requ; i ad Not Required Registration Number. 418-P010009727A-000-000-0000000-0000 Registratic:;; Date/Time: 02/16/2018 12:31 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Vei lion - CF1 R-02082018-1016 SP2 04 CFM50 n/a HERS Provider: CHEERS Report Generated at. 2018-02-16 12:23:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPI aNCE METHOD Project Name: SINGLE HOUSE ADDITION Calculation Date/Time: 12:22, Fri, Feb 16, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpC0C1.tmp.xml WATER HEATING SYSTEMS 01 02 03 Name System Type Distribution Type DHW Sys 1 DHW Standard WATER HEATERS 01 02 03 04 05 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniforr Factor Factor / DHW Heater 1 Gas Small Storage 1 50 0.5i SPACE CONDITIONING SYSTEMS 01 02 03 SC Sys Name System Type Heating Unit Name WHOLE HOUSEI Other Heating and Cooling System Heating Component 1 HVAC - HEATING UNIT TYPES 01 Name Heating Component 1 HVAC - COOLING UNIT TYPES 01 02 03 Name System Type Number of I Cooling Component 1 SplitAirCond 1 CFI R-PRF-01 Page 5 of 7 04 05 06 07 08 Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Heater 1 1 0 Existing No 07 08 09 10 11 12 nergy nergy iciency Input Rating I Pilot / Thermal Efficiency Tank Insulation R-value (IntlExt) Standby Loss / Recovery Eff First Hour Rating I Flow Rate NEEA Heat Pump Brand / Model Tank Location or Ambient Condition =F 37,000 Btu/hr 0 n/a n/a n/a n1a 04 05 06 07 08 Cooling Unit Name Fan Name Distribution Name Status Verified Existing Condition Cooling Component onent 1 HVAC Fan 1 Air Distribution System 1 Existing No 02 istem Type nrlFurnace 04 1 05 Efficiency pits EER SEER 9.2 10 Registration Number 418-P010009727A-000-000-0000000-0000 Registrati� i Date/Time: 02/16/2018 12:31 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Vc; sion - CF1 R-02082018-1016 SP2 03 Number of Units 1 06 07 04 Efficiency 80 AFUE 08 Zonally Controlled Compressor Type I HERS Verification _F_ Not Zonal Single Speed Cooling Component 1-hers-coo! HERS Provider. CHEERS Report Generated at: 2018-02-16 12:23:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLI. tiNCE METHOD Project Name: SINGLE HOUSE ADDITION Calculation Date/Time: 12:22, Fri, Feb 16, 2018 Calculation Description: Title 24 Analysis Input File Name: trnpC0C1.tmp.xmi HVAC COOLING - HERS VERIFICATION 01 02 Name Verified Airflow Cooling Component 1-hers-cool Not Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 Name Type Duct Leakage Insulation R-value Air Distribution System 1 Ducts located in attic (Ventilated and Unventilated) Existing (not specified) 6.0 IAQ (Indoor Air Quality) FANS 01 02 Name IAQ CFM SFam IAQVentRpt 0 CF1 R-PRF-01 Page 6 of 7 03 04 05 06 irflow Target Verified EER Verified SEER Verified Refrigerant Charge n/a Not Required Not Required Not Required 05 06 07 08 09 10 Supply Duct Location Return Duct Location Bypass Duct Status Verified Existing Condition HERS Verification Attic Attic None Existing + New No n/a 03 04 05 IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification Default 0 Not Required Registration Number. 418-P010009727A-000-000-0000000-0000 Registration Date/Time: 02/16/2018 12:31 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02082018-1016 SP2 Report Generated at: 2018-02-16 12:23:06 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPL, NCE METHOD Project Name: SINGLE HOUSE ADDITION Calculation DatelTime: 12:22, Fri, Feb 16, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpC0C1.tmp.xm1 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Raymond Zhong Company: Perfect Design Address: 2416 W. Valley Boulevard CitylState/Zip: Alhambra, CA91803 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept r< 2. 1 certify that the energy features and performance specifications identified on thi Regulations. 3. The building design features or system design features identified on this Certific worksheets, calculations, plans and specifications submitted to the enforcement pon Ressible Designer Name: Company: INAPA [DESIGNS: Address: MI$51 1 VIEJO, CA 92592 City/State/Zip: EMAIL: MARKDESIGNS201`WGMAIL.COM.. CF1 R-PRF-01 Page 7 of 7 1~SSf Documentation Author fdaymrrrrifrZD�rsru� 'O�!E'VGy� Signature Date: 02/16/2018 M-276395 M w3br- "�'n r, - 2 0 CEA/HERS Certificati ff If a pl' s� �CHAc,►"o¢ Phone: 626-289-8808 -=slbility for the building design identified on this Certificate of Compliance. :ertificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of of Compliance are consistent with the information provided on other applicable compliance documents, aency for approval with this building permit application. Responsible Design ignature: Date Signed: License: Phone: Digitally signed by CHEERSTm. This digital signature is provided j, order to secure the content of this registered document, and in no way implies Registration Provider responsit i;:y for the accuracy of the information. Registration Number: 418-P010009727A-000-000-000000o-0000 Registratic:i DatelTime: 02116/2018 12:31 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Ve, _ion - CF1 R-02082018-1016 SP2 Report Generated at: 2018-02-16 12:23:06 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name SINGLE HOUSEADDITION Building Type ® Single Family ❑ Addition Alone ❑ Multi Family m Existing+Addition/Alteration Date 211612018 Project Address 52293 EISENHOWER LA QUINTA California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 1,361 246 4 of Units 1 INSULATION Area Construction Type Cavity ff Special Features Status Roof Wood Framed Attic R 38 246 New Wall Wood Framed R 15 966 New Slab Unheated Slab -on -Grade no insulation 246 Perim = 40' New Roof Wood Framed Attic - no insulation 1,115 Existing Wall Wood Framed no insulation 807 Existing Slab Unheated Slab -on -Grade no insulation 1,115 Perim = 115' Existing FENESTRATION Total Area: -Orientation Area ft2 U-Fac 163 Glazing Percentage: 12.0% ° IVewiAltered Average U-Factor: SHGC Overhang Sidefins Exterior Shades 0.32 Status Rear (W) 53.6 0.320 0.25 none none Bug Screen New Rear (W) 44.0 1.190 0.83 none none Bug Screen Existing Front (E) 20.0 1.190 0.83 none none Bug Screen Existing Right (N) 28.0 1.190 0.83 none none Bug Screen Existing Left (S) 17.5 1.190 0.83 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Setback Existing HVAC DISTRIBUTION Location Heatin Cooling Duct Location Duct R-Value Status WHOLE HOUSE Ducted Ducted Attic 6.0 Altered WATER HEATING Qty. Type Gallons Min. Eff Distribution Status I-EneroyPra 726 EneraySoft User Number 1919 ID-A18-131R PA&. rn ,f 7i 00k, 2016 Low -Rise Residential Mandatory Measures Summary NOTE. Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. *Exceptions may apply. Un Inal ud"ZU110 Building Envelope Measures: § 110.6(a)l : Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per NFRC-400 or ASTM E283 or AAMAIWDMA/CSA I Ol/I.S.2/A440-2011 ' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.13•A and 110.E-B for compliance and must be caulked and/or weatherstd ed,' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather slri ed. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g).- Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of 110.8 i when the installation of a cool roof is specified on the CF1R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on 1,op of a dryolali ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or § 150.0(c): less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed as5e!nbl .' § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 permiinch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8 . § 150.0(g)1: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class i or Class II vapor retarder. This r uirement also applies to controlled ventilation crawls ace forbuildin s complying with the exception to § 150.0(d). 150.0(g)2 Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be Installed on the conditioned space side of all § r^ i + n it n!I "n to4 ..u;, - 4 ­,, n+,4 -,u , 11141�,­­r kl, - •i +;- 150.0 § (q)' rdoaairauuu r'r4uuCt8. renesuation, INIUUIng sKyugnrs, separating conditoned space tiom unconamoned space or outdoors must have a maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)18: Combustion Intake, Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is a u ipped with a madit accessible, operable, and tig ht-ft[tin g dam er oreombustion-air control device.' § 150.0(e)l C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110 0 § 110 3: Certification, Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.' § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110-3(c)5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushinU when the valves are closed. § 110.5: Pilot Lights. Continuously buming pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supp1y voltage connection with pilot lights that consume less than 150 Btu/hr are exempt): and pool and spa heaters,' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions s ecifled in § 150.0 h 2_ 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: _ Liquid Line Drier- Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 mtemal insulation where the internal insulation R-va[ue is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures-- § 150.00)28: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.` § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00?2A. Distribution i ping for steam and h ydronic h eating systems or hat waters stems must meet the requirements in TABLE 120-3-A-' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause d radation of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)l : 120V electrical receptacle within 3 feet of the water heater, a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200.000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Co oration SRCC or bX a [isfing agencythat is apgwyed lby the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CIVIC). If a contractor installs the insulation, the contractor must certify to the customer, in writin , that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604A, 605.0 and ANSUSMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CIVIC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing and ,inner ^!'' "le'•.,I mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts: Factory -Fabricated Duct Systems, Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems mustcomply with applicable requirements for: pressure-sensilive tapes, mastics, sealants, and other requirements specified for duct construction, § 150,0(m)7: Backdraft Dampers, All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dam ers- § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside except combustion inlet and outlet air openings and elevator shaft vents. Protection of insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m l land Reference Residential Appendix RA3. Air Filtration, Mechanical systems that supply airto an occupiable space through ducrviork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, ressure dro , and labelin re uirements of 150.0 m 12. 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airsystems * Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Aependix RAU. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting: a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.' § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 11 U., § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JAB high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JAB. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) elevated tern erature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of & 150.0(kl' Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix -JAB. Installed lamps must be marked with "JAB-2016" or JA8-2016-E" as specified in Reference Joint Appendix JAB.* § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JAB compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5(f); and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 1 30.5ft and all other requirements in § 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmer according to J 110.9, and complies with all other a icabie requirements in § 150.0 k . 2016 Low -Rise Residential Mandatary Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. _ § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS) Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0(k)3A or with the applicable requirements in 110.9, 130.0,130.2.130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0(k)3B or § 150.0 k 3D must comply with the applicable requirements in §§ 110.9. 130.0, 130.2. 130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the a2plicable requirements in §§ 110,9, 130.0, 130.2, 130A. 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 waits of power as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the apDlicable requirements for nonresidential garages in 110.9.130.0, 130.1. 130.4, 140.6. and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0,130.1, 140.6 and 141.0; and ii Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all desi ned paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110A0(b) through 6110.10(e). § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local /or,e iu[a! �! ea s cc r,u :ur sY❑ U71 clt,la 'J!dl !,E,v r , .: _ :c i;e c. ,._ each tar buildings with root areas less than or equal to 1u,uuu square teet or no less than IbU square feet each for buildings with roof areas § 110.10(b)1 greater than 10,OOO square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 Dercent of the total roof area of the building excluding any skylight area' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment! Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)38: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel): and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 110.10(c) must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location: and pennanentiv marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name SINGLE HOUSE ADDITION Date 2/16/2018 System Name WHOLE HOUSE Floor Area 1,361 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1 3.028 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 54,000 43,256, 1,202 983 40,412 Total Output Btuh 54,000 0 Output Btuh/s ft 39.7 2,952 2,331 Cooling System 0 0 Output per System 34,000 0 0 0 0 Total Output Btuh 34,000 0 2,952 49,160 1,202 0 Total Output Tons 2.8 2,331 Total Output Btuhls ft 25.0 Total Output s ft/Ton 480.2 E:id Air S tem CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow (cfm) 1,200 EXISTING A/C UNIT 22,248 9,255 54,000 Airflow (cfm/sgft) 0.88 Airflow cfm/Ton 423.5 Outside Air (%) 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 22,248 9.2551i 54,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions I Aug 3 PN7 HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) L-1 1 Outside Air 1 - - 0 cfm Supply Fan Heating Coil 107 OF 1,200 cfm ROOM- Z 66 OF 68 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak 112/78'IF 80/67OF 80/68'IF 63/62OF � !rti Outside Air !` 0 cfm Supply Fan Cooling Coil 65 / 62 OF 1,200 cfm 80 / 67 OF 56.6% ROOM 78/67OF I EnergyPro 7.2 by EnergySoft User Number: 1919 ID: A18-1318 Page 15 of 211 ZONE LOAD SUMMARY Project Name SINGLE HOUSE ADDITION Date 211612018 System Name WHOLE HOUSE Floor Area 1,361 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible ADDI T10N AREA 10 0 Aug 3 PM 253 3,609 217 88 3,612 EXISTING AREA 10 0 Aug 3PM 2,776 39,647 985 895 36,800 ROOM LOAD SUMMARY Project Name SINGLE HOUSE ADDITION Date 211612018 System Name WHOLE HOUSE Floor Area 1,361 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible ADDITION AREA ADDITION AREA 1 253 3,609 217 253 3,609 217 88 3, 612 EXISTING AREA EXISTING AREA 1 2,776 39,647 985 2,776 39,647 9851895 36,800 PAGE TOTAL 3,0281 43,256 1.2021 983 40,412 3,028 43,256 1.202 983 40,412 ROOM HEATING PEAK LOADS Project Name SINGLE HOUSE ADDITION Date 211612018 ROOM INFORMATION DESIGN CONDITIONS Room Name ADDITION AREA Floor Area 245.50 ff2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area R-38 Roof Attic 245.5 R-15 wall 262.4 Doubt® Non Metal Clear (6y 53.6 'R-15 Wall 352.0 Slab -On -Grade Perim = 39.5 Items shown with an asterisk () denote conduction through an interior surface Infiltration:[ 1.00 X 1.064 X 246 X Schedule Air Sensible Area Fraction X X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x to Coiling U-Value AT °F Btu/hr X 42 = 258 X 42 = 1,047 X 42 = 720 X 0 = 0 X 42 = 1,211 x x x = x = x = x = x = x = x = x = x = x = x x = x x = x = x = x = x = x = x = x = x = x = x J= Page Total 3,236 / 60 ] X 42 = 376 AT 0.0250 0.0950 0.3200 0.0950 0.7300 another room 8.00 X 0.257 Height ACH TOTAL HOURLY HEAT LOSS FOR ROOM 3,612 EnergyPrc 7.2 by Enertgy5oft user Number.' 1919 (D: A 18-1218 Pege i8 of 21 ROOM HEATING PEAK LOADS Project Name SINGLE HOUSE ADDITION Room Name Floor Area Indoor Dry Bulb Conduction Default Roof 1950 to Present. Default Wall Prior 1950 to Present Default Single Metal Clear 'R-15 Wall Slab -On -Grade EXISTING AREA I Time of Peak 1,115.00 ftz Outdoor Dry Bulb Temperature 68 °F Area U-Value X X 0.3000 X X 0.3560 X 1.1900 X X 0.0950 X X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X X /\ X X X X X X X X X X X X Items shown with an asterisk (") denote conduction through an interior surface to another room Date 211612018 AT OF Page Total Jan 1 AM 26 OF Btu/hr 14,049 12,059 5,473 0 3,511 1 35,0911 1.00 X 1.064 X 1,115 X 8.00 X 0.257 / 60 ] X 42 = Infiltration:[ Schedule Air Sensible Area Ceiling Height ACH AT Fraction AL HOURLY HEAT LOSS FOR 1 1,7091 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date SINGLE HOUSE ADDITION 211612018 ROOM INFORMATION DESIGN CONDITIONS Room Name ADDITION AREA Outdoor Dry Bulb Temperature 112 OF Floor Area 245.50 ft2 Outdoor Wet Bulb Temperature 78 of Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btulhr R-38 Roof Attic (N) 245.5 X 0.0250 X 56.0 = 344 R-15 Wall (W) 62.4 X 0,0950 X 33.0 = 196 R-15 Wall (E) 88.0 X 0.0950 X 33.0 = 276 R-15 Wall (S) 112.0 X 0.0950 X 26.0 = 277 *R-15 Wall 352.0 X 0.0950 X 0.0 = 0 X X = X X = X X = X X = Page Total 1,092 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btulhr WINDOWS fW) 0.0 X 15.7 + 53.6 X 30.5 = 1,636 x + X = X + X = X + X = X + X = X + X + - X = X + X = X + X = Page Total 1-636 Internal Gain Btulhr Occupants 0•7 Occupants X 245 Btuh/occ. Fsgft - F�4109 18 Equipment 246 Floor Area X 0.50 w/ = Infiltration: 1.064 X 0•87 X 9-D0 X 34 = 282 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 3.609 Latent Gain Btulhr Occupants 0 7 Occupants X 155 Btuh/occ. = 1 r4 Infiltration: 4,771 X 0.87 X 9.001 X I00276 = 103 Air Sensible CFM ELh AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 114 EnarqyEro 7.2 by EneraySoft User Number: 1919 ID: A 18-13 18 Pa e 20 of 21 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date SINGLE HOUSE ADDITION 211612018 ROOM INFORMATION DESIGN CONDITIONS Room Name EXISTING AREA Outdoor Dry Bulb Temperature 112 OF Floor Area 1,115.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Ranae: 34 OF 0nanue Surfar_ac Default Roof 1950 to Present, Default Wall Prior 1950 to Present Default Wall Prior 1950 to Present Default Wall Prior 1950 to Present Default Wall Prior 1950 to Present *R-15 Wall Orientation (N) (S) Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = = = 1,115.0 0.3000 56.0 176.0 0.3560 33.0 228.0 0.3560 33.0 252.0 0.3560 23.0 150.5 0,3560 26.6 352.0 0.0950 0. C Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestratlon WINDOWS WINDOWS WINDOWS WINDOWS Orientation Area GLF Area GLF 0.0 X 52.6 + 44.0 X 98.6 = 0.0x 52.6 + 20.0X 98.6= 0.0 X 52.6 + 28.0 X 52.6 = 0.0X 52.6+ 17.5X 52.8= X + X = X + T X = X + X - X + X = Page Total Internal Gain Occupants 3 3 Occupants X 245 Btuh/occ. Eauipment 1,115 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 0,87 X 40.88 X 31 = Alr Sensible CFM ELA AT TOTAL HOURLY SENSIBLE: HEAT GAIN FOR ROOM Latent Gain 3.3 Occupants X I Btuh/occ. _ Infiltration: 4,771 X 0.87 X 40.88 X 0.00276 = Air5ensible CFM ELA AW Btu/hr 98, 732 2, ose 2, 679 1 26, Btu/hr 4,340 1,973 1,472 8, Btu/hr 2 1.6 39, f Btulhr TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 51M l knergyPro 7.2 by_EnergySoft_ User Number: 1919 ID: A18-1318 Paae 21 of 211