BRES2018-0311Twit D � Qal4a
VOICE (760) 777-7125
78-495 CALLE TAMPICO 00 �� FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 2/26/2019
Permit Type/Subtype: BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED Owner:
Application Number: BRES2018-0311 DEBORAH CANEDO
Property Address: 48750 AVENIDA EL NIDO 31704 PEPPER TREE ST.
APN: 658300011 WINCHESTER, CA 09259-6
Application Description: CANEDO / 3,942SF DWELLING/VB/RES-3/CLASS A-FR/13D
Property Zoning:
Application Valuation: $357,166.70
Applicant: Contractor:
EDO
OWNER BUILD - DEBORAH CANEDO [� `� 31704PDEBORAH PER THE
LEI �� _�,
31704 PEPPER TREE ST. 31704 PEPPER TREE ST.
WINCHESTER, CA 92596 2 6 2019 WINCHESTER, CA 92596
FEBG I (619)846-5513
CITY OF LAQUiNTA Llc. No.::CONV:140528101254133574
DESIGN & DEVELOP RENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
{commencing with Section 7000) of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: _ License No.::CONV;140528101254133574
Date: Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or County that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
alteged exemption. Any violation of Sectian 7031.5 by any applicant for a permit
N applicant to a civil penalty of not more than five hundred dollars ($500).:
s owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale- If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or sh Id 'bt build or improve for the purpose of sale.).
-�1.Jjhb)wner of the property, am exclusively contracting with licensed contractors to
Hnstruct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractor(s) licensed pursuant to the
Cont�aetors' State License Law.).
` to exempt under Sec. . B.&P.C. for this reason
Date: i f Owner: [�
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's Add
WORKER'S COMPENSATION DECLARATION
hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers'
-ompensation, as provided for by Section 3700 of the Labor Code, for the performance
:)f the work for which this permit is issued.
_ I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
slued. My workers' compensation insurance carrier and policy number are:
rrner: Policy Number:
certify that in the performance of the work tar which this permit is issued, I
sh not employ any person In any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: Applicant: Ir
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance ofthis permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of Issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this ci ente pa above -
mentioned property for inspection purposes. ti
Date:}? � �%� Signature•(ApplicantorAgent�-
Application Number:
BRES2018-0311
Property Address:
48750 AVENIDA EL NIDO
APN:
658300011
Application Description:
CANEDO / 3,942SF DWELLING/VB/RES-3/CLASS A-FR/13D
Property Zoning:
Application Valuation:
$357,166.70
Applicant:
OWNER BUILD - DEBORAH CANEDO
31704 PEPPER TREE ST.
WINCHESTER, CA 92596
Date: 2/26/2019
Owner:
DEBORAH CANEDO
31704 PEPPER TREE ST.
WINCHESTER, CA 09259-6
Contractor:
DEBORAH CANEDO
31704 PEPPER TREE ST.
WINCHESTER, CA 92596
(619)846-5513
Llc. No.::CONV:140528101254133574
Detail: 3,942SF SINGLE FAMILY DWELLING [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL, SPA OR GATES. 2016
CALIFORNIA BUILDING CODES.
DESCRIPTION ACCOUNT CITY AMOUNT
ART IN PUBLIC PLACES - RESIDENTIAL 270-0000-43201 0 $392.91
Total Paid for ART IN PUBLIC PLACES - AIPP: $392.91
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$15.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $15.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - CIVIC CENTER
252-0000-43200
0
$942.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - COMMUNITY CENTERS
254-0000-43200
0
$129.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - FIRE PROTECTION
257-0000-43200
0
$433.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - LIBRARIES
253-0000-43200
0
$344.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - PARK MAINTENANCE
256-0000-43200
0
$40.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - PARKS/REC
251-0000-43200
0
$2,048.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - STREET MAINTENANCE
255-0000-43200
0
$116.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - TRANSPORTATION
250-0000-43200
0
$2,842.00
Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TEMP POWER SERVICE
101-0000-42403
0
$26.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TEMP POWER SERVICE PC
101-0000-42600
0
$18.20
Total Paid for ELECTRICAL: $44.21
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF
101-0000-42403
0
$66.30
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF, PC
101-0000-42600
0
$27.30
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$156.04
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600 1
0
$51.49
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $301.13
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF
101-0000-42408
0
$39.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT>7KSF PC
101-0000-42600 1
0 $195.05
Total Paid for GRADING: $234.06
DESCRIPTION
ACCOUNT
CITY
AMOUNT
AIR HANDLER
101-0000-42402
0
$312.08
DESCRIPTION
ACCOUNT
CITY
AMOUNT
AIR HANDLER PC
101-0000-42600
0
$104.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
CONDENSER/COMPRESSOR
101-0000-42402
0
$117.03
DESCRIPTION
ACCOUNT
CITY
AMOUNT
CONDENSER/COMPRESSOR PC
101-0000-42600
0
$78.03
DESCRIPTION
ACCOUNT
CITY
AMOUNT
EXHAUST HOOD
101-0000-42402
0
$26.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
EXHAUST HOOD PC
101-0000-42600
0
$10.40
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN
101-0000-42402
0
$117.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN PC
101-0000-42600
0
$46.80
Total Paid for MECHANICAL: $811.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
MULTI -SPECIES RESIDENTIAL 0-8 UNITS - 2018 UPDATE
101-0000-20310
0
$1,290.00
Total Paid for MULTI -SPECIES RESIDENTIAL: $1,290.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
NEW CONSTRUCTION PERMIT
101-0000-42400
0
$722.10
Total Paid for NEW CONSTRUCTION PERMIT: $722.10
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($1,200.00)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
NEW CONSTRUCTION PLAN CHECK
101-0000-42600
0
$1,200.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
NEW CONSTRUCTION PLAN CHECK
101-0000-42600
0
$344.39
Total Paid for NEW CONSTRUCTION PLAN CHECK: $344.39
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PLAN CHECK DEPOSIT - RESIDENTIAL
101-0000-42600
1
$1,200.00
Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $1,200.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BACKFLOW DEVICE
101-0000-42401
0
$13.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BACKFLOW DEVICE PC
101-0000-42600
0
$5.20
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$312.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$312.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 5+ OUTLETS
101-0000-42401
0
$39.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 5+ OUTLETS PC
101-0000-42600
0
$26.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ROOF DRAIN
101-0000-42401
0
$156.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ROOF DRAIN PC
101-0000-42600
0
$156.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SEPTIC SYSTEM
101-0000-42401
0
$13.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SEPTIC SYSTEM PC
101-0000-42600
0
$13.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER HEATER/VENT
101-0000-42401
0
$13.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER HEATER/VENT PC
101-0000-42600
0
$7.80
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$13.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$13.00
Total Paid for PLUMBING FEES: $1,092.02
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$46.43
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $46.43
DESCRIPTION ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE 502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SINGLE FAMILY DETACHED
224-0000-20320
0
$1,837.44
Total Paid for TUMF - RESIDENTIAL: $1,837.44
�+
G4J
--^— CS rt t4 nj-iie-r)FSFR'T
PERMIT # U5I15 -❑ l j
PLAN LOCATION:
Project Address/--Zl-
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
Applicant Name:
Address:
City, ST, Zip: G
Telephone: 16e' 9
F-Mail: *A
Valuation of Project $�
Contractor Name: I
New SFD Construction:
Address: ��
Conditioned Space
3 �ZSF
City, St, Zip k�
r
Garage
Patio/Porch
SF
SF
Telephone: 10 RAV6
Email: dJ � �-
AO
Fire Sprinklers
r F
State Lie: City Bus Lie:
Arch/Eng Name: d
Construction Type: Occupancy:
Grading:
Address:` S „ •
City, St, Zipw
Telephone: /� �-14t
Bedrooms: Stories: # Units:
Email:
State Lie: City Bus Lie:
IF
Property Owner's Name:
New Commercial / Tenant Improvements:
Address: 4-",5 1� �
Total Building SF
City, ST, Zip W
Construction Type: Occupancy:
Telephone:
Email:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
OFFICE USE ONLY
#
Submittal
Plan Sets
Req'd
Rec'd
Structural Calcs
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
CERTIFICATE OF COMPLIANCE
N,f�Fa
Desert Sands Unified School District
ry`��$
47950 Dune Palms Road
Date: 2/26/2019
La Quinta, CA 92253
No.: 19-01255-1
(760)771-8515
Nl �'"''I'
-
y'
Owner: Deborah Canedo & Alex Gerba
Email:
Address: 48750 Avenida El Nido
Jurisdiction:
La Quinta
City: La Quinta
Tract #:
Type: Single Family Residential
Lot # Street No.
48750
Comments:
Street Name Sq. Feet APN Permit No.
Avenida El Nido 3942 658-300-011
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fess imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $3.79 X 3942 S.F. or $14,940.18 have been paid for the property listed above and that building
permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Fees Paid By: CC/Mission,.,FP.d�era_(IQ
Bank Name/Recipient of Certificate
By Scott L. Bailey
Superintendent
Fee Collected/ Exempted by: Arianne Catano
Check No.: 150001233207
Telephone: 619-846-5516
Funding: Residential
Certificate Fees Due: $14,940.18
Original Paymert(s) Rec'd: $0.00
New Payment Rec:'d: $14,940.18
Over;/Linder: $0.00
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the Fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
RECORDING REQUESTED BY
Lawyers Title - LA
AND WHEN RECORDED MAIL TO:
Deborah C. Canedo
Alex M. Gerba
31704 Pepper Tree St.
Winchester, CA 92596
APN: 658-300-011-4
TITLE ORDER NO.: 618641623
ESCROW NO.: 18-2382-BC
DOC # 2018-0209677
05/24/2018 12:30 PM Fees: $30.00
Page 1 of 3
Recorded in Official Records
County of Riverside
Peter Aldana
Assessor -County Clerk -Recorder
"This document was electronically submitted
to the County of Riverside for recording"
Receipted by: CAROL #914
Space above this Ilne for Recarder's use
GRANT DEED
TRA: 020-003 SB2 — AFFORDABLE HOUSING EXEMPTION DECLARATION
CITY: LA QUINTA
OTT: $203.50
"Exempt from fee per GC 27388.1(a) (2); recorded concurrently "in connection with" a transfer
subject to the imposition of documentary transfer tax"
SEPARATE PAGE - PURSUANT TO GOVERNMENT CODE 27361.6
l �s r RScJ
o.
-FEB 2 6 2019
CITYCLAQr�JNTA
RECORDING REQUESTED BY:
Lawyers Title
WHEN RECORDED MAIL DOCUMENT AND
TAX STATEMENT TO:
Deborah C. Canedo
Alex M. Gerba
31704 Pepper Tree St.
Winchester, CA 92596
APN: 658-300-011-4
TITLE ORDER NO.: 618641623
ESCROW NO.: 18-2382-BC
TRA # 020-003
DOC #2018-0209677 Page 2 of 3
THIS SPACE FOR REGUKUtK'J ux UNLT
GRANT DEED
The undersigned Grantor(s) declare(s) that the DOCUMENTARY TRANSFER TAX IS: County $2 0 3.50
_computed on the full value of the interest of property conveyed, or
_computed on the full value less the value of liens or encumbrances remaining thereon at the time of sale.
OR transfer is EXEMPT from tax for the following reason:
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Michael D. Sheehy,
Deborah C. Canedo, a single woman and Alex M. Gerba,
an unmarried man as Joint Tenants
HEREBY GRANT(S) to
r*
All that real property situated in the City of La Quinta, County of Riverside, State of California, described as:00
� As
per Exhibit "A" attached hereto and made a part hereof for legal description. +l*rr- A yoI'+� YvO
jqrs 3d L3 pry
Commonly Known As: 48750 Avenida El Nido (Vacant Lot), La Quinta, CA 92253 �,py ulfrs Sri �+1
77Z& 0
Dated: May 15, 2018
rialttached,
notary public officer or other officer completing this certificate verifiesonly the
entity of the Individual who signed the document to which this certificate Is
and not the truthfulness, accurac cr validi of that document
STATE OF )
COUNTY OF
On l� before me,
a Notary Public
personallya1ppeare tG
r U]G � � �.� . Jr i] f.'t✓i1
who proved to me on the basis of satisfactory evidence to be the person(s)
whose name(s) Is/are subscribed to the within Instrument and acknowledged to
me that he/she/they executed the same in his/her/their authorized capacily(les),
and that by hislhedtheir signature(s) on the instrument the person(a), or the
entity upon behalf of which the person(s) acted, executed the instrument.
I certify under PENALTY OF PERJURY under the laws of the State of
California that the foregoing paragraph is true and correct.
WITNESS my hand and official seal
Signature
(SEAL)
AM Y S. ECCLES
; q. 02uuty Andilor, was hingtonCovi%, KrnssQI6
;. Nolanal officer (ex-o4llola notary public)
=': My term Is indetermNata
DOC #2018-0209677 Page 3 of 3
EXHIBIT "A"
All that certain real property situated In the County of Riverside, State of California, described as
follows:
THAT PORTION OF LOT 64 OF LA QUINTA GOLF ESTATES N0, 1, IN THE CITY OF LA QUINTA,
COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS SHOWN BY MAP ON FILE IN BOOK 37 PAGES
96 THROUGH 98 OF MAPS, RECORDS OF RIVERSIDE COUNTY, CALIFORNIA, MORE PARTICULARLY
DESCRIBED AS FOLLOWS:
BEGINNING AT THE SOUTHWEST CORNER OF SA10 LOT 84, SAID CORNER BEING ON A CURVE
CONCAVE TO THE SOUTHWEST HAVING A RADIAL BEARING OF SOUTH 640 49' 54" WEST, TO THE
CENTER OF SAID CURVE, AND A RADIUS OF 525.00 FEET;
THENCE NORTHWESTERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 90 01' 17" A
DISTANCE OF 82.56 FEET, TO A REVERSE CURVE, CONCAVE TO THE SOUTHEAST HAVING A
RADIUS OF 20.00 FEET, SAID CURVE ALSO BEING THE WESTERLY LINE OF SAID LOT 84;
THENCE NORTHEASTERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 820 05' 38", A
DISTANCE OF 28.66 FEET, TO A COMPOUND CURVE CONCAVE TO THE SOUTHEAST HAVING A
RADIUS OF 1675.00 FEET, SAID CURVE BEING THE NORTHWESTERLY LINE OF SAID LINE OF SAID
LOT 84;
THENCE NORTHEASTERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 30 09' 54", A
DISTANCE OF 92.53 FEET, SAID CURVE BEING A PORTION OF THE NORTHERLY LINE OF SAID LOT
84;
THENCE SOUTH 360 18' 55" EAST, A DISTANCE OF 45.67 FEET;
THENCE SOUTH 290 06' 51" EAST, A DISTANCE OF 65.54 FEET; THENCE SOUTH 220 08' 27"
WEST, A DISTANCE OF 9.15 FEET, TO A TANGENT CURVE CONCAVE TO THE SOUTHEAST HAVING
A RADIUS OF 6.86 FEET;
THENCE SOUTHERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 460 25, 2211, A
DISTANCE OF 5.56 FEET;
THENCE, TANGENT TO SAID CURVE, SOUTH 24° 48' 27" EAST, A DISTANCE OF 7.72 FEET, TO A
POINT ON THE SOUTHERLY LINE OF SAID LOT 84;
THENCE, SOUTHWESTERLY ALONG SAID LINE SOUTH 64* 49' 54" WEST, A DISTANCE OF 101.06
FEET TO THE SOUTHWEST CORNER OF SAID LOT 84, SAID POINT ALSO BEING THE POINT OF
BEGINNING;
Assessor's Parcel N mbe : 658-300-011-4
This must be in red to be a
"CERTIFIED COPY"
I hereby certify the foregoing instrument to
w1ticl1�t,his stamp has been affixed consisting
Of --:~ pages to be a full, true and co E�h'
correct copy of the original on file and �.
of record in my office.
y
En M
Assessor - County Clerk - Recorder
County of Riverside, State of California w
FEB 2 6 lr
Dated:. m 41
Certification must be in red to be a
"CERTIFIED COPY"
RECORDING REQUESTED BY and
WHEN RECORDED MAIL TO:
Bradley W. Nemeth
9635 Granite Ridge Drive, Ste. 320
San Diego, CA 92123
• MAIL TAX STATEMENTS TO
Alex M. Gerbe
Deborah C. Canedo
31704 Pepper Tree Street
Winchester, CA 92596
APN NO. 658-300-011-4
2019-0047645
02/11/2019 01:14 Piz Fee: $ 105.00
Page 1 of 3
Recorded in Official Records
County of Riverside
Peter Aldana
Assessor -County Clerk -Recorder
IIPWAYG;MASiMi]@PIIII
QUITCLAIM DEED 420
THE UNDERSIGNED GRANTOR(s) declare(s) under penalty of perjury that this is a transfer to a revocable
trust for the benefit of the Grantor(s) and is exempt under the Revenue and Taxation Code and THERE IS
NO CONSIDERATION FOR THIS TRANSFER.
DOCUMENTARY TRANSFER TAX is $0; CITY TAX $0
City of La Quinta, County of Riverside
GRANTOR(S): DEBORAH C. CANEDO, a single woman and ALEX M. GERBA, an unmarried man, as joint
tenants,
hereby REMISE(S), RELEASE(S) and FOREVER QUITCLAIM(S) to:
DEBORAH C. CANEDO, Trustee, U.T.D. December 13, 2018 and ALEX M. GERBA, Trustee,
U.T.D. December 13, 2018, as tenants in common
the following described real property in the City of La Quinta, County of Riverside, State of California:
That portion of Lot 84 of La Quinta Golf Estates No. 1, in the City of La Quinta, County of Riverside, State of
California, as shown by Map on File in Book 37 Pages 95 through 98 of Maps, Records of Riverside County,
California as more particularly described on Exhibit "A" attached hereto and incorporated by reference.
Commonly Known as: 48750 Avenida El Nido (Vacant Lot), La Quinta, CA 92253
Dated: December 13, 2018
Dated: December 13, 201 B
i7EBORAH C. CANEDO
ALEX M. GERBA
DOC #2019-0047645 Page 2 of 3
A notary public or other officer completing this
certificate verifies only the identity of the individual
who signed the document to which this certificate is
attached, and not the truthfulness, accuracy, or validity
of the document.
STATE OF CALIFORNIA
COUNTY OF SAN DIEGO ) SS
On December 13, 2018, before me, De Ann De Chellis, A Notary Public, personally appeared
DEBORAH C. CANDEO and ALEX M. GERBA, who proved to me on the basis of satisfactory
evidence to be the person(s) whose name(s) is/are subscribed to the within instrument, and
acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies),
and that by his/her/their signature(s) on the instrument the person(s) or the entity upon behalf of
which the person(s) acted, executed the instrument.
I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing
paragraph is true and correct.
WITNESS my hand and official seal.
Signat
M
DE CHELLIS jblic —California
San Diago County >
Commission 2197792
u" MyComm,ipJ1
. r. . . DOC #2019-0047645 Page 3 of 3
EXHIBIT `"A"
All that certain real property situated In the County of Riverside; State of California, described as
follows:
THAT PORTION OF LOT 84 OF LA QUINTA GOLF ESTATES NO. 1, IN THE CITY OF LA QUINTA,
COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS SHOWN BY MAP ON FILE IN BOOK 37 PAGES
96 THROUGH 98 OF MAPS, RECORDS OF RIVERSIDE COUNTY, CALIFORNIA, MORE PARTICULARLY
DESCRIBED AS FOLLOWS:
BEGINNING AT THE SOUTHWEST CORNER OF SAID LOT 84, SAID CORNER BEING ON A CURVE
CONCAVE TO THE SOUTHWEST HAVING A RADIAL BEARING OF SOUTH 640 49' 54" WEST, TO THE
CENTER OF SAID CURVE, AND A RADIUS OF 525.00 FEET;
THENCE NORTHWESTERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 90 01' 17" A
DISTANCE OF 82.56 FEET, TO A REVERSE CURVE, CONCAVE TO THE SOUTHEAST HAVING A
RADIUS OF 20.00 FEET, SAID CURVE ALSO BEING THE WESTERLY LINE OF SAID LOT 84;
THENCE NORTHEASTERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 820 05' 38% A
DISTANCE OF 28.66 FEET, TO A COMPOUND CURVE CONCAVE TO THE SOUTHEAST HAVING A
RADIUS OF 1675.00 FEET, SAID CURVE BEING THE NORTHWESTERLY LINE OF SAID LINE OF SAID
LOT 84;
THENCE NORTHEASTERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 30 09' 54', A
DISTANCE OF 92,53 FEET, SAID CURVE BEING A PORTION OF THE NORTHERLY LINE OF SAID LOT
84;
THENCE SOUTH 360 18' 55" EAST, A DISTANCE OF 45.67 FEET;
THENCE SOUTH 290 06' 51" EAST, A DISTANCE OF 65.S4 FEET; THENCE SOUTH 220 08' 27"
WEST, A DISTANCE OF 9.15 FEET, TO A TANGENT CURVE CONCAVE TO THE SOUTHEAST HAVING
A RADIUS OF 6.86 FEET;
THENCE SOUTHERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 460 25' 22', A
DISTANCE OF 5.56 FEET;
THENCE, TANGENT TO SAID CURVE, SOUTH 24° 48' 27' EAST, A DISTANCE OF 7.72 FEET, TO A
POINT ON THE SOUTHERLY LINE OF SAID LOT 84;
THENCE, SOUTHWESTERLY ALONG SAID LINE SOUTH 64* 49' 54" WEST, A DISTANCE OF 101.06
FEET TO THE SOUTHWEST CORNER OF SAID LOT 84, SAID POINT ALSO BEING THE POINT OF
BEGINNING;
Assessor's Parcel Number:,658-300-011-4
This must be in red to be a
"CERTIFIED COPY"
I hereby certify the foregoing instrument to
which this stamp has been affixed consisting GO��Tv Q r.
of _pages to be a full, true and
correct copy of the original on file and
of record in my office. y
* ._ _ Q
Assessor - County Clerk - Recorder
County of Riverside, State of California
Dated:
10
Certification must be in red to be a
"CERTIFIED COPY"
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
PROPERTY OWNER'S PACKAGE
(760)777-7012
FAX (760) 777-7011
Disclosures & Forms for Owner -Builders Applying for Construction Permits
IMPORTANT! NOTICE TO PROPERTY OWNER
Dear Property Owner:
An application for a building permit has been submitted in your name listing yourself as the builder of the property
improvements specified at Q L
We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your
responsibilities and possible risk you may incur by having this permit issued in your name as the
Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision,
signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice
unless you, the property owner, obtain the prior approval of the permitting authority.
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION
DRECTfONB: React and initial each statement below to sign6 you understand or verify this information.
- - I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner Builder"
ding permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as
an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while working on my. property. My homeowner's insurance may not provide coverage for those
injuries. I any willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers
on my property.
2. I understand building permits are not required to be signed by property owners unless they are responsible for the
nstruction and are not hiring a licensed Contractor to assume this responsibility.
pI understand as an "Owner Builder" I am the responsible party of record on the permit. I understand that I may protect
yse4li from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my
own.
4.1 understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on
exrrtits and contracts.
I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value
my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer"
under state and federal law.
166-I understand if I am considered an "employer" under state and federal law, I must register with the state and federal
ment, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment
compensation for each "employee." I also understand my failure to abide by these laves may subject me to serious financial
risk. I
�(�9. I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential
ructures cannot legally build them with the intent to offer them for sale, unless alt work is performed by licensed
subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed
under contract with a licensed general building Contractor.
I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any
racial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the
workmanship or materials.
4. I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue
ervice, the United States Small Business Administration, the California Department of Benefit Payments, and the California
Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-
800-321-CSLB (2752) or www.csib.ca.gov for more information about licensed contractors.
eay,
0. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the
legally and financially responsible for proposed construction activity at the following address:
s s ,s-3
I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all
licable laws and requirements that govern Owner -Builders as.well as employers.
2. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I
ve provided on this form. Licensed contractors are regulated by Iaws designed to protect the public. If you contract with
someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss
you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also
important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working
on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire. Contractors,
you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers'
compensation insurance coverage.
Before a building permit can be issued, this form must be completed and signed by the property owner and returned to
the agency responsible for issuing the permit. Note. A copy of the property owner's driver's license, form notarization, or
other verification acceptable to the agency is required to be presented when the perneir is issued to verb rite properly
owner's signature.
Signature of property o.w<z Date: IJ-112
Note: The following Authorization Form is required to be completed by theproperty owner only when designating
an agent of the property owner to apply for a construction per►nit for the Owner -Builder.
AUTHORIZATION Or, AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which l understand is my personal responsibility, I hereby authorize
the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder
Permit for my project.
Scope of Construction Project (or Description of Work):
Project Location or Address:
Name of Authorized Agent:
Address of Authorized Agent:
Tel No
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above
information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification
acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature.
Property Owner's Signature: Date:
CITY OF LA QUINTA SUB -CONTRACTOR, LIST
JOB ADDRESS,S��L.L /1/i�j D PERMIT NUMBER&" 3id;�/OWNER;BUILDER
This farm shall be _posted an the -job with the, SuildincL Inspection Card at all times in a conspicuous place. Only perso[fs appearing on this list or their employees are authorized to work
on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance
of building permit. For each aoolicable trade. all information ranuestP.d halnw m11ct hP rmmnlntPri by nnnlir-nnt "()n Fdl " is nn+
Trade-1. C..Lassifica;#ian
G'a tr.:aota..r
State Contractor.'s.License
Workers
Workers. Compensation In.s.uranGe.....---
cit Bus'
-
Classification
License Number
Exp. Date
Carrier Name
Policy Number
Exp. Date
License Number
'Exp. Date
Company Name
(e.g. A, B, C-8)
(xxxxxx)
(xx/xx/xx)
(e.g. State Fund, CalComp)
(Format Varies)
(xx/xx/xx)
(xxxx)
((x}x/xx/xx)
EARTHWORK
8 v2s P
ie -i-
178.
T
CONCRETE: {C:-8.)
�ES��2 F i�
.Z
S D
2 2 S-
FRAMING (C-5)
t^
STRUCT. STEEL (C.5 ()
R%• A
MASONRY (C-29.)
57-
1 Jo ,2 s'
PL<JMB[NG (.C-3.6)
4,e AQ
a d z
LATH;; PLASTER
Z 7/
cr
DRYWALL {G=9:)
2 OZ3f
HVAC. (:C-20.)
2 O
/OD 9
IF
�d 3!
o
Ae
ELECTRfCA1 (C-To)
T �` -L -
C "I7
AV
� J
2k/-Xo „/�y��d/a'�
ROOFING (C.39}
�
SHEET METAL (C-43)
�[.
FLOORING JC-15)
-*
G.LAZIN.G (.C47)
INSULATION. {C,2)
SEWAGE DISP. (C-421
-PAINTING W-331
oullyxx ---
CERAMIC TILE (C-54)
Le>EX - •L
CA..B.INETS (C-6)
--
FENCING (C-13)��
LANDSCAPING (C-27)�
POOL W-53)
Ira
r
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
La Quinta Residence
48750 El Nido
La Quinta, CA 92253
Project Designer:
Nader's Design Consulting, Inc
5959 Mission Gorge Road Ste. 203
San Diego, CA 92120
619-284-1848
Report Prepared by:
Brian Hansen
Technical Energy
4336 Goldfinch St
San Diego, Ca 92103
858-472-2680
Job Number:
18-294
Date:
2/12/2019
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE �'�� BYJ;�
9R%lo►b • 0311
i +®yTt r r
' 1 i
FEB 14 2019
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
I TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF-1 R-PRF-01-E Certificate of Compliance
2
3
i Form RMS-1 Residential Measures Summary 11
CtRTiFICATE OF (:OMNLIANCE - RESIUENI IAL PEkFORMANCE COMPLIANCE METHOD
Project Name: La Quinta Residence Calculation Date/Time: 07:34, Fri, Feb 08, 2019
Calculation Description: Title 24 Analysis Input File Name: 18-294.6 La Quinta.ribdl6x
GENERAL
INFORMATION
01
Project Name
La Quinta Residence
02
Calculation Description
Title 24 Analysis
03
Project Location
48750 El Nido
04
City
La Quinta
06
Zip Code
92253
08
Climate Zone
CZ15
10
Building Type
Single Family
12
Project Scope
Newly Constructed
14
Total Cond. Floor Area (ft2)
3942
16
Slab Area (ft2)
3942
18
Addition Cond. Floor Area(ft2)
n/a
20
Addition Slab Area (ft2)
n/a
CF1 R-PRF-01
Pagel of 8
05
Standards Version
Compliance 2017
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
Software Version
EnergyPro 7.2
Front Orientation (deg/Cardinal)
0
Number of Dwelling Units
1
Number of Zones
1
Number of Stories
1
Natural Gas Available
Yes
Glazing Percentage (%)
18.9%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
1.42
2.24
-0 82
-57 7%
Space Cooling
83.70
76.43
7.27
8.7%
IAQ Ventilation
0.98
0.98
0.00
0.0%
Water Heating
4.16
3.43
0.73
17.5%
Photovoltaic Offset
....
0.00
0.00
.----
Compliance Energy Total
90.26
83.08
7.18
8.0%
Registration Number: 218-Po10257254F-000-000-0000000-0000 Registration Date/Time: 2019-02-11 10:53:27 HERS Provider:
CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-08 07:35:54
CF1 R-PRF-01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: La Quinta Residence Calculation Date/Time: 07:34, Fri, Feb 08, 2019
Calculation Description: Title 24 Analysis
Input File Name: 18-294.6 La Quinta.ribd16x
Page 2 of 8 _
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency
EDR of Proposed Efficiency
EDR Value of Proposed PV + Battery
Final Proposed EDR
52.7
49.5
0.0
49.5
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV)
renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified.
Notes:
• Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Raised heel truss
• Cool roof
• Insulation below roof deck
• Window overhangs and/or fins
• Non-standard duct location (any location other than attic)
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Ducts located within the conditioned space (except < 12 lineal ft)
Domestic Hot Water System Verifications:
--None --
Registration Number: 218-Po10257254F-000-000-0000000-0000 Registration Date/Time: 2019-02-11 10:53:27 HERS Provider: CaICERTS ine.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-08 07:35:54
CLRTIFICATE OF (:OMPLIANCE - RESIUENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: La Quinta Residence Calculation Date/Time: 07:34, Fri, Feb 08, 2019
Calculation Description: Title 24 Analysis
Input File Name: 18-294.6 La Quinta.ribd16x
CF1 R-PRF-01
Page 3 of 8
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
La Quinta Residence
3942
1
5
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
1st floor
Conditioned
(n) heat pump1
3942
11
DHW Sys 1
n/a
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft)
Tilt (deg)
(n) Front Wall
1 st floor
R-19 Wall
0
Front
920
202
90
(n) Left Wall
1 st floor
R-19 Wall
90
Left
880
24.7
90
(n) Back Wall
1 st floor
R-19 Wall
180
Back
920
227
90
(n) Right Wall
1st floor
R-19 Wall
270
Right
880
315.345
90
Roof
1 st floor
R-38 Roof Attic
n/a
n/a
3942
n/a
n/a
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic 1 st floor
Attic Roof st floor
Unventilated
0
0.3
0.75
No
Yes
Registration Number: 218-Po10257254F-000-000-0000000-0000 Registration Date/Time: 2019-02-11 10:53:27 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-08 07:35:54
CERTIFICATE OF COMPLIANCE - RESIUENTIAL PERFORMANCE COMPLIANt;E METHOD
Project Name: La Quinta Residence Calculation Date/Time: 07:34, Fri, Feb 08, 2019
CF1 R-PRF-01
Page 4of8
Calculation Description: Title 24 Analysis
Input File Name: 18-294.6 La Quinta.ribd16x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft)
U-factor
SHGC
Exterior Shading
(n) 4080 door
Window
(n) Front Wall (Front-0)
----
•••.
1
32.0
0.51
0.23
Insect Screen (default)
(n) 8080 door
Window
(n) Front Wall (Front-0)
---•
1
64.0
0.51
0.23
Insect Screen (default)
(n) 8080 door 2
Window
(n) Front Wall (Front-0)
--
1
64.0
0.51
0.23
Insect Screen (default)
(n) 4620 window
Window
(n) Front Wall (Front-0)
----
----
1
9.0
0.34
0.24
Insect Screen (default)
(n) 4620 pool bath window
Window
(n) Front Wall (Front-0)
----
1
9.0
0.34
0.24
Insect Screen (default)
(n) 10018 window
Window
(n) Left Wall (Left-90)
--
--
1
16.7
0.34
0.24
Insect Screen (default)
(n) 4020 window
Window
(n) Left Wall (Left-90)
- -
-
1
8.0
0.34
0.24
Insect Screen (default)
(n) 5020 window
Window
(n) Back Wall (Back-180)
-•-
1
10.0
0.34
0.24
Insect Screen (default)
(n) 5050 window
Window
(n) Back Wall (Back-180)
----
----
1
25.0
0.34
024
Insect Screen (default)
(n) 6080 door
Window
(n) Back Wall (Back-180)
1
48.0
0.51
0.23
Insect Screen (default)
(n) 6080 door 2
Window
(n) Back Wall (Back-180)
1
48.0
0.51
023
Insect Screen (default)
(n) 6080 door 3
Window
(n) Back Wall (Back-180)
--
1
48.0
0.51
0.23
Insect Screen (default)
(n) 6080 door 4
Window
(n) Back Wall (Back-180)
----
1
48.0
0.51
0.23
Insect Screen (default)
(n) 4450 window
Window
(n) Right Wall (Right-270)
1
21.7
0.34
0.24
Insect Screen (default)
(n) 10018 window 2
Window
(n) Right Wall (Right-270)
-
1
16.7
0.34
0.24
Insect Screen (default)
(n) 10050 window
Window
(n) Right Wall (Right-270)
----
1
50.0
0.48
0.20
Insect Screen (default)
(n) 6050 window
Window
(n) Right Wall (Right-270)
6.0
5.0
1
30.0
0.34
0.24
Insect Screen (default)
(n) 8626 window
Window
(n) Right Wall (Right-270)
---
----
1
21.3
0.34
0.24
Insect Screen (default)
(n) 8626 window 2
Window
(n) Right Wall (Right-270)
--
1
21.3
0.34
0.24
Insect Screen (default)
(n) 4626 window
Window
(n) Right Wall (Right-270)
--
1
11.3
0.34
0.24
Insect Screen (default)
(n) 2720 pool bath window
Window
(n) Right Wall (Right-270)
----
----
1
5.0
0.34
0.24
Insect Screen (default)
(n) 14980 door
Window
(n) Right Wall (Right-270)
14.8
8.0
0.997
118.0
0.51
0.23
Insect Screen (default)
(n) 2680 door
Window
(n) Right Wall (Right-270)
----
--
1
20.0
0.51
0.23
Insect Screen (default)
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
3080 Door
(n) Front Wall
24.0
0.50
Registration Number: 218-Po10257254F-000-000-0000000-0000 Registration Date/Time: 2019-02-11 10:53:27 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-08 07:35:54
CERTIFICATE OF COMPLIANCE - RESIUENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: La Quinta Residence Calculation Date/Time: 07:34, Fri, Feb 08, 2019
CF1 R-PRF-01
Page 5 of 8
Calculation Description: Title 24 Analysis
Input File Name: 18-294.6 La Quinta.ribdl6x
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
(n) 6050 window
10
0.1
0
10
0
0
0
0
0
0
0
0
0
(n) 14980 door
10
0.1
0
10
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
• Around Roof Joists: R-25.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof st floor
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 38
0.037
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
R 19 in 5-1/2 in.
Cavity/Frame: R-19 in 5-1/2 in. (R-18) /2x6
R-19 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.0
cavity (R-18)
0.074
Exterior Finish: 3 Coat Stucco
Ceilings (below
2x4 @ 16 in. O C with Raised Heel
Inside Finish: Gypsum Board
R-38 Roof Attic
attic)
Wood Framed Ceiling
Truss Height 16 in
none
0.472
Cavity/Frame: no insul. /2x4
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Slab -on -Grade
1st floor
3942
360
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1 (1)
1
.0%
Registration Number: 218-P010257254F-000-000-0000000-0000 Registration Date/Time: 2019-02-11 10:53:27 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-08 07:35:54
CF1 R-PRF-01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: La Quinta Residence Calculation Date/Time: 07:34, Fri, Feb 08, 2019
Calculation Description: Title 24 Analysis
Input File Name: 18-294.6 La Quinta.ribd16x
Page 6 of 8
WATER HEATERS
01
02
03
04
05
06
07
08
09
` 10
11
12
Input Rating /
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss I
First Hour
NEEA Heat Pump
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
Brand / Model /
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Other
Condition
Consumer
DHW Heater 1
Gas
Instantaneous
1
0
0.96 UEF
<= 200 kBtu/hr
R-0/R-0
0
8 GPM
n/a
n/a
(UEF)
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
(n) heat pump1
Heat Pump Heating and
Cooling System
Heat Pump System 1
Heat Pump System 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEAT PUMPS
01
02
03
04
05
06
07
08
09
10
11
Name
System
Type
Number of
Units
Heating
Cooling
Zonally
Controlled
Compressor
Type
HERS
Verification
HSPF/COP
Cap 47
Cap 17
SEER
EER
Heat Pump System 1
SplitHeatPump
3
10.5
42000
32000
15.6
12.6
Not Zonal
Single Speed
Heat Pump System
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Heat Pump System 1-hers-cool
Required
350
Required
Required
Not Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctslnEx12
Sealed and tested
6
Conditioned zone
(except < 12')
None
Air Distribution System
1-hers-dist
Registration Number: 218-P010257254F-000-000-0000000-0000 Registration DatefTime: 2019-02-11 10:53:27 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-08 07:35:54
CF1 R-PRF-01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: La Quinta Residence Calculation Date/Time: 07:34, Fri, Feb 08, 2019
Calculation Description: Title 24 Analysis
Input File Name: 18-294.6 La Quinta.ribdl6x
Page 7 of 8
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
5.0
Required
Not Required
Not Required
Not Required
n/a
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
84
0.25
Default
0
Required
Registration Number: 218-Po10257254F-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration Date/Time: 2019-02-11 10:53:27
Report Version - CF1 R-01162019-1149
HERS Provider: CaICERTS inc.
Report Generated at: 2019-02-08 07:35:54
CERTIFICATE OF COMPLIANCE - RESIUENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: La Quinta Residence Calculation Date/Time: 07:34, Fri, Feb 08, 2019
CF1 R-PRF-01
Page 8 of 8
Calculation Description: Title 24 Analysis
Input File Name: 18-294.6 La Quinta.ribdl6x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Brian Hansen
Company:
Signature Date:
Technical Energy
2019-02-09 20:35:10
f��
�����r
Address:
CEA/HERS Certification Identification (If applicab
4336 Goldfinch St
R16-14-20069
-f*`— A'e�uFc. of Ruff u Flu•, (ra„alto„t
City/State/Zip:
Phone:
San Diego, CA 92103
858-472-2680
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature- _
_
z ���'
Nader Hedjran'�
Company:
Date Signed:
Nader's Design Consulting, Inc.
2019-02-11 10:53:27
Address:
License:
5959 Mission Gorge Rd. Ste. 203
NA
City/State/Zip:
Phone:
San Diego, CA 92120
619-284-1848
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 218-P010257254F-000-000-0000000-0000 Registration Date/Time: 2019-02-11 10:53:27
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149
0. 0
Easy to Verify
at CaICERTS.com
HERS Provider: CaICERTS inc
Report Generated at: 2019-02-08 07:35:54
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
La Quinta Residence
Building Type
10 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
211212019
Project Address
48750 El Nido La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,942
Addition
n/a
# of Units
1
INSULATION
Construction Type
Cavity
Area
(ft) Special Features
Status
Wall Wood Framed
R19
2,831
New
Door Opaque Door
-
no insulation
24
New
Roof Wood Framed Attic
- no insulation
3,942 Add=R-38.0 Cool Roof
New
Slab Unheated Slab -on -Grade
- no insulation
3,942 Perim = 360'
New
FENESTRATION
Orientation Area(ft)
I Total Area 745 Glazing Percentage. 18.9 %
U-Fac SHGC Overhang Sidefins
NewlAltered Average U-Factor 0-46
Exterior Shades Status
Front (N) 160.0
0.510
0.23 none
none
Bug Screen
New
Front (N) 18.0
0.340
0.24 none
none
Bug Screen
New
Left (E) 24.7
0.340
0.24 none
none
Bug Screen
New
Rear (S) 35.0
0.340
0.24 none
none
Bug Screen
New
Rear (S) 192.0
0.510
0.23 none
none
Bug Screen
New
Right (Vlq 97.3
0.340
0.24 none
none
Bug Screen
New
Right (Vtq 50.0
0.480
0.20 none
none
Bug Screen
New
Right (Vtq 30.0
0.340
0.24 10.0
none
Bug Screen
New
Right (Aq 118.0
0.510
0.23 10.0
none
Bug Screen
New
Right (lnq 20.0
0.510
0.23 none
none
Bug Screen
New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
3 Split Heat Pump
10.50 HSPF
Split Heat Pump 15.6 SEER
Setback
New
HVAC DISTRIBUTION
Location Heating
Cooling
Duct Location
Duct
R-Value Status
(n) heat pump Ducted
Ducted
Conditioned
6.0
New
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
1 Small Instantaneous Gas
0
0.96
Standard
New
EneravPro 7.2 byEneravSoft User Number- 1082
ID- 1R-294
Pana 11 of 1R
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. `Exceptions may apply.
Keviseo u4rzu-i r
Building Envelope Measures:
§ 110.6(a)1:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per
NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.'
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
110,6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.'
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 110.8 i when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a).
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceiling.*
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value
Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-
§ 150.0(c):
factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed
value of R-13 in a wood framed assembly.*
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.'
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration: and, when installed as part of a heated slab floor, meet the requirements of § 110.8 .
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
§ 150.0(g)1:
requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150,0(d).
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
§ 150.0(g)2:
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
150.0
§ (q)
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)1A:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1 B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)1 C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.*
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)5.
§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
§ 110.5:
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool ands a heaters.'
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150,0(h)l
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J usina design conditions specified in 6150.0(h)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
d er vent.
§ 150.0(h)3B:
Liquid Line Drier, Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 Inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.'
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve.'
§ 150.00)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.'
§ 150.0(j)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause de radation of the material.
§ 150.00)38:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II va or retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following a
§ 150.0(n)1:
120V electrical receptacle within 3 feet of the water heater; a Category Ili or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation SRCC or by a listing agency that is apj2roved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation the contractor must cerilly to the customer, in writin that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0. 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1:
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/< inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not Wcompressed to cause reductions in the cross -sectional area of the ducts.'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tape is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic -dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually aerated dampers in all openings to the outside, except combustion inlet and outlet air o enin s and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0m 1land Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pmssure dro and label in re uiremenls of § 150.0m 12.
2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced airs stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
§ 150.0(o)1A:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RAU.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.'
§ 110.4(b)l :
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light,
150.0
§ (p)'
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, piping, filters, and valves.'
Lighting Measures:
§ 110.9.
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of § 110.9.'
§ 110.9(e):
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)l B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)l D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors.
§ 150.0(k)1 F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(k).'
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)l G:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8.'
§ 150.0(k)l H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems."
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k .
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5 f ; and meets all other requirements in § 150.0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150,0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5 ; and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
Drovides the functionality of a dimmer according to S 110.9. and comolies with all other aDDlicable requirements in 6150.0(k)2.
el
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacant sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JA8, except luminaires in closets less than 70 square feet and luminaires in hallways:
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS.
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either § 150.0 k 3A or with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0 k 3B or 150.0 k 3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2. 130.4, 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7. and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in J§ 110.9,130.0.130.1, 130.4 140.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high Wicacy luminaires and controlled by an occu ant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 Rercent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requi of § 110.10 b through 1110.10 e ,
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.*
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest p2int of the solar zone, measured in the vertical lane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.1 0c must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and penanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
La Quinta Residence
System Name
(n) heat pump
Date
2/12/2019
Floor Area
3,942
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
3
COIL
CFM
Total Room Loads 2,970
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output perSystem
42,000
50,922
4,100
2,494
55,407
Total Output (Btuh)
126,000
0
Output Btuh/s ft
32.0
788
646
Cooling System
0
0
Output per System
36,0001
0
0
0
0
Total Output (Btuh)
108,000
2,579
4,100
-2,579
Total Output (Tons)
9.0'
788
646
Total Output (Btuh/s ft)
27.4
Total Output s ft/Ton
438.0,
1 55,078
54,120
Air System
CFM per System
1,200
HVAC EQUIPMENT SELECTION
Airflow cfm
3.600
Mitsubishi PUMY-P36NKMU
65,884
31,961
78,696
Airflow (cfm/sgft)
0.91
Airflow (cfm/Ton)
400.0
Outside Air (%
0-0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
65,884
31,961
78,696
Jan 1 AM
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS
Airstream Tem eratures at Time of Heating
Peak)
26 OF
Outside Air Ar
0 cfm
70 OF
70 OF 90 OF 91 OF
Heating Coil Supply Fan
3,600 cfm
� 1 I f �•
91 OF
ROOM >
70 °F
'
COOLING SYSTEM PSYCHROMETRICS
Airstream Tem eratures at Time of Cooling
Peak
112/78OF
Outside Air
0 cfm
78 / 66 OF
78/66°F 61 /60°F 62/60°F
0 0U I
Cooling Coil Supply Fan
3,600 cfm
n �_
r I
62 / 60 OF
53.7 % ROOM
11!_
78 / 66 OF
1
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: La Quinta Residence Calculation Date/Time: 07:34, Fri, Feb 08, 2019
CF1 R-PRF-01
Page 1 of 8
Calculation Description: Title 24 Analysis
Input File Name: 18-294.6 La Quinta.ribd16x
GENERAL INFORMATION
01
Project Name
La Quinta Residence
02
Calculation Description
Title 24 Analysis
03
Project Location
48750 El Nido
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3 1 (1149)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.2
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
0
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
3942
15
Number of Zones
1
16
Slab Area (ft2)
3942
17
Number of Stories
1
18
Addition Cond. Floor Area(ft2)
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ft2)
n/a
21
Glazing Percentage (IN
88.9%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
1.42
2.24
-0.82
-57.7%
Space Cooling
83.70
76.43
7.27
8.7%
IAQ Ventilation
0.98
0.98
0.00
0.0%
Water Heating
4.16
3.43
0.73
17.5%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
90.26
83.08
7.18
8.0%
Registration Number: 218-P010257254F-000-000-0000000-0000 Registration Date/Time: 2019-02-11 10:53:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-08 07:35:54
CtRTIFICATE OF L;OMNLIANCt - RESWEN NAL PEkFOKMANCE COMPLIANCE METHOD CF1 R-PRF-01
Project Name: La Quinta Residence Calculation Date/Time: 07:34, Fri, Feb 08, 2019 Page 2 of 8
Calculation Description: Title 24 Analysis Input File Name: 18-294.6 La Quinta.ribd16x
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR
52.7 49.5 0.0 49.5
❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV)
renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and Qli must be verified.
Notes:
• Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
Raised heel truss
• Cool roof
• Insulation below roof deck
• Window overhangs and/or fins
• Non-standard duct location (any location other than attic)
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Ducts located within the conditioned space (except < 12 lineal ft)
Domestic Hot Water System Verifications:
• --None --
Registration Number: 218-Po10257254F-000-000-0000000-0000 Registration Daterrime: 2019-02-11 10.53:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-08 07:35:54
i
CERTIFICATE -OF COMPLIANCE - kESIUENTIAL PEKFOKMANCE COMPLIANCE METHOD
Project Name: La Quinta Residence Calculation Date/Time: 07:34, Fri, Feb 08, 2019
CF1 R-NRF-01
Page 3 of 8
Calculation Description: Title 24 Analysis
Input File Name: 18-294.6 La Quinta.ribd16x
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ftZ)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
La Quinta Residence
3942
1
5
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ftZ)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
1st floor
Conditioned
(n) heat pump1
3942
11
DHW Sys 1
n/a
OPAQUE SURFACES
01
02
03
04
05
06 1
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ftZ)
Window & Door Area (ftZ)
Tilt (deg)
(n) Front Wall
1 st floor
R-19 Wall
0
Front
920
202
90
(n) Left Wall
1st floor
R-19 Wall
90
Left
880
24.7
90
(n) Back Wall
1st floor
R-19 Wall
180
Back
920
227
90
(n) Right Wall
1st floor
R-19 Wall
270
Right
880
315.345
90
Roof
1 st floor
R-38 Roof Attic
n/a
n/a
3942
n/a
n/a
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic 1 st floor
Attic Roof st floor
Unventilated
0
0.3
0.75
No
Yes
Registration Number: 218-Po10257254F-000-000-0000000-0000 Registration Date/Time: 2019-02-11 10:53:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-08 07:35:54
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: La Quinta Residence Calculation Date/Time: 07:34, Fri, Feb 08, 2019
CF1 R-PRF-01
Page 4 of 8
Calculation Description: Title 24 Analysis
Input File Name: 18-294.6 La Quinta.ribd16x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft)
U-factor
SHGC
Exterior Shading
(n) 4080 door
Window
(n) Front Wall (Front-0)
----
----
1
32.0
0.51
0.23
Insect Screen (default)
(n) 8080 door
Window
(n) Front Wall (Front-0)
----
----
1
64.0
051
023
1 Insect Screen (default)
(n) 8080 door 2
Window
(n) Front Wall (Front-0)
----
----
1
64.0
0.51
0.23
Insect Screen (default)
(n) 4620 window
Window
(n) Front Wall (Front-0)
----
----
1
9.0
0.34
0.24
Insect Screen (default)
(n) 4620 pool bath window
Window
(n) Front Wall (Front-0)
----
----
1
90
0.34
0.24
Insect Screen (default)
(n) 10018 window
Window
(n) Left Wall (Left-90)
--•-
1
16.7
0.34
0.24
Insect Screen (default)
(n) 4020 window
Window
(n) Left Wall (Left-90)
1
8.0
0.34
0.24
Insect Screen (default)
(n) 5020 window
Window
(n) Back Wall (Back-180)
1
10.0
0.34
0.24
Insect Screen (default)
(n) 5050 window
Window
(n) Back Wall (Back-180)
1
25.0
0.34
0.24
Insect Screen (default)
(n) 6080 door
Window
(n) Back Wall (Back-180)
-
-
1
48.0
0.51
0.23
Insect Screen (default)
(n) 6080 door 2
Window
(n) Back Wall (Back-180)
----
-
1
48.0
0.51
0.23
Insect Screen (default)
(n) 6080 door 3
Window
(n) Back Wall (Back-180)
----
----
1
48.0
0.51
0.23
Insect Screen (default)
(n) 6080 door 4
Window
(n) Back Wall (Back-180)
----
----
1
48.0
0.51
0.23
Insect Screen (default)
(n) 4450 window
Window
(n) Right Wall (Right-270)
1
21.7
0.34
0.24
Insect Screen (default)
(n) 10018 window 2
Window
(n) Right Wall (Right-270)
----
----
1
16.7
0.34
0.24
Insect Screen (default)
(n) 10050 window
Window
(n) Right Wall (Right-270)
.---
----
1
50.0
0.48
0.20
Insect Screen (default)
(n) 6050 window
Window
(n) Right Wall (Right-270)
6.0
5.0
1
30.0
0.34
0.24
Insect Screen (default)
(n) 8626 window
Window
(n) Right Wall (Right-270)
----
----
1
21.3
0.34
0.24
Insect Screen (default)
(n) 8626 window 2
Window
(n) Right Wall (Right-270)
--
1
21.3
0.34
0.24
Insect Screen (default)
(n) 4626 window
Window
(n) Right Wall (Right-270)
1
11.3
0.34
0.24
Insect Screen (default)
(n) 2720 pool bath window
Window
(n) Right Wall (Right-270)
.---
----
1
5.0
0.34
0.24
Insect Screen (default)
(n) 14980 door
Window
(n) Right Wall (Right-270)
14.8
8.0
0.997
118.0
0.51
0.23
Insect Screen (default)
(n) 2680 door
Window
(n) Right Wall (Right-270)
--
----
1
20.0
0.51
0.23
Insect Screen (default)
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ftZ)
U-factor
3080 Door
(n) Front Wall
24.0
0.50
Registration Number: 218-P010257254F-000-000-0000000-0000 Registration Date/Time: 2019-02-11 10:53:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-08 07:35:54
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: La Quinta Residence Calculation Date/Time: 07:34, Fri, Feb 08, 2019
CF1 R-PRF-01
Page 5 of 8
Calculation Description: Title 24 Analysis
Input File Name: 18-294.6 La Quinta.ribd16x
OVERHANGS AND FINS
01
02
03
04
05
06
07
08 09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
(n) 6050 window
10
0.1
0
10
0
0
0
0
0
0
0
0
0
(n) 14980 door
10
01
0
10
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
• Around Roof Joists: R-25.0 insul.
Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof st floor
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 38
0.037
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
R 19 in 5-1/2 in.
Cavity/Frame: R-19 in 5-1/2 in. (R-18) /2x6
R-19 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
cavity (R-18)
0.074
Exterior Finish: 3 Coat Stucco
Ceilings (below
2x4 @ 16 in. O.C. with Raised Heel
Inside Finish: Gypsum Board
R-38 Roof Attic
attic)
Wood Framed Ceiling
Truss Height 16 in
none
0.472
Cavity/Frame: no insul. /2x4
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Slab -on -Grade
1 st floor
3942
360
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1 (1)
1
.0%
Registration Number: 218-P010257254F-000-000-0000000-0000 Registration Date/Time: 2019-02-11 10:53:27 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-08 07:35:54
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: La Quinta Residence Calculation Date/Time: 07:34, Fri, Feb 08, 2019
CF1 R-PRF-01
Page 6 of 8
Calculation Description: Title 24 Analysis
Input File Name: 18-294.6 La Quinta.ribdl6x
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Input Rating /
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
NEEA Heat Pump
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
Brand / Model /
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Other
Condition
Consumer
DHW Heater 1
Gas
Instantaneous
1
0
0 96 UEF
<= 200 kBtu/hr
R-0/R-0
0
8 GPM
n/a
n/a
(UEF)
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
(n) heat pumpl
Heat Pump Heating and
Cooling System
Heat Pump System 1
Heat Pump System 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEAT PUMPS
01
02
03
04
05
06
07
08
09 1
10
11
Name
System
Type
Number of
Units
Heating
Cooling
Zonally
Controlled
Compressor
Type
HERS
Verification
HSPF/COP
Cap 47
Cap 17
SEER
EER
Heat Pump System 1
SplitHeatPump
3
10.5
42000
32000
15.6
12.6
Not Zonal
Single Speed
Heat Pump System
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Heat Pump System 1-hers-cool
Required
350
Required
Required
Not Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
Ducts1nEx12
Sealed and tested
6
Conditioned zone
(except < 12')
None
Air Distribution System
1-hers-dist
Registration Number: 218-Po10257254F-000-000-0000000-0000 Registration Date/Time: 2019-02-11 10:53:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-08 07:35:54
CERTIFICATE OF COMPLIANCE - RESWENT1AL PEkFORMANCE COMPLIANCE METHOD
Project Name: La Quinta Residence Calculation Date/Time: 07:34, Fri, Feb 08, 2019
CF1 R-PRF-01
Page 7 of 8
Calculation Description: Title 24 Analysis
Input File Name: 18-294.6 La Quinta.ribd16x
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
5.0
Required
Not Required
Not Required
Not Required
n/a
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
84
0.25
Default
0
Required
Registration Number: 218-P010257254F-000-000-0000000-0000 Registration Date/Time: 2019-02-11 10:53:27 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-08 07:35:54
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: La Quinta Residence Calculation Date/Time: 07:34, Fri, Feb 08, 2019
Calculation Description: Title 24 Analysis Input File Name: 18-294.6 La Quinta.ribdl6x
CF1 R-PRF-01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete
Documentation Author Name:
Documentation Author Signature:
Brian Hansen'Y'siaP,xi
Company:
Signature Date:
Technical Energy
2019-02-09 20:35:10-`
A E C
Address:
CEA/HERS Certification Identification (If applicabl
LR
4336 Goldfinch St
R16-14-20069
�IM1;r mA"�.1!. r Cr Y; l -:1 Fn-I r .- ill .- t%
- -
City/State/Zip:
Phone:
San Diego, CA 92103
858-472-2680
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature
Nader Hedjran
Company:
Date Signed:
Nader's Design Consulting, Inc.
2019-02-11 10:53:27
Address:
License:
5959 Mission Gorge Rd. Ste. 203
NA
City/State/Zip:
Phone:
San Diego, CA 92120
619-284-1848
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 218-P010257254F-000-000-0000000-0000 Registration Date/Time: 2019-02-11 10:53:27
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149
0�
Easy to Verify
at CaICERTS.com
HERS Provider: CaICERTS inc
Report Generated at: 2019-02-08 07:35:54