Loading...
BRES2018-041878-495 CALLE TAMPICO T4h/ D " P Qum& VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 3/29/2019 Permit Type/Subtype: BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY ATTACHED Owner: Application Number: BRES2018-0418 KJT 232, LLC. Property Address: 53584 VIA PALACIO 53584 VIA PALACIO APN: 777220018 LA QUINTA, CA 92253 Application Description: THOMAS / 5,725SF DWELLING Property Zoning: Application Valuation: $501,685.20 Applicant: y ` Contractor: KJT 232, LLC. u OWNER BUILDER - RYAN THOMAS 73399 EL PASEO STE # 101 D 80135 VIA VALEROSA PALM DESERT, CA 92260 MAR 2 9 2019 LA QUINTA, CA 92253 CIT`f OF IAQuINTA (760)972-7504 DESIGN & DEVELOPMENT DEPARTMENT Llc. No.: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit s the applicant to a civil penalty of not more than five hundred dollars ($500).: s owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he 0 Id not build or improve for the purpose of sale.), ass owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date Owner : CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: CaPolicy Number: rri_ ertify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Da t plic WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above - mentioned property for inspection purposes. , Oat . Signature (Applicant or Agent Date: 3/29/2019 Application Number: BRES2018-0418 Property Address: 53584 VIA PALACIO APN: 777220018 Application Description. THOMAS / 5,725SF DWELLING Property Zoning: Application Valuation: $501,685.20 Applicant: KJT 232, LLC. 73399 EL PASEO STE # 101 PALM DESERT, CA 92260 Owner: KJT 232, LLC. 53584 VIA PALACIO LA QUINTA, CA 92253 Contractor: OWNER BUILDER - RYAN THOMAS 80135 VIA VALEROSA LA QUINTA, CA 92253 (760)972-7504 Llc. No.: Detail: 5,725SF DWELLING - [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2016 CALIFORNIA BUILDING CODES. FINANCIAL DESCRIPTION ACCOUNT CITY AMOUNT ART IN PUBLIC PLACES - RESIDENTIAL 270-0000-43201 0 $754.21 Total Paid for ART IN PUBLIC PLACES - AIPP: $754.21 DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($250.00) DESCRIPTION ACCOUNT CITY AMOUNT HOURLY CHARGE - INTERWEST STRUCTURAL PLAN REVIEW 101-0000-42600 2 $250.00 Total Paid for BLDG CITY STAFF - PER HOUR: $0.00 DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $21.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $21.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - LIBRARIES 253-0000-43200 0 $344.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARKS/REC 251-0000-43200 0 $2,048.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 DESCRIPTION ACCOUNT CITY AMOUNT SERVICES 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT SERVICES PC 101-0000-42600 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT TEMP POWER SERVICE 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT CITY I AMOUNT TEMP POWER SERVICE PC 101-0000-42600 1 0 $18.68 Total Paid for ELECTRICAL: $85.38 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $95.27 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $39.20 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $160.10 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $52.83 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $347.40 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT>7KSF 101-0000-42408 0 $40.02 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF PC 101-0000-42600 0 $200.12 Total Paid for GRADING: $240.14 DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($133.40) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($200.10) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($5.34) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($13.34) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($133.40) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($200.10) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($53.40) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($133.40) DESCRIPTION ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $200.10 DESCRIPTION ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $133.40 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD 101-0000-42402 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD PC 101-0000-42600 0 $5.34 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE 101-0000-42402 0 $200.10 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE PC 101-0000-42600 0 $133.40 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN 101-0000-42402 0 j $133.40 DESCRIPTION ACCOUNT CITY I AMOUNT VENT FAN PC 101-0000-42600 10 $53.40 Total Paid for MECHANICAL: $0.00 DESCRIPTION ACCOUNT CITY AMOUNT NEW CONSTRUCTION PERMIT 101-0000-42400 0 $829.23 Total Paid for NEW CONSTRUCTION PERMIT: $829.23 DESCRIPTION ACCOUNT CITY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,789.67 Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,789.67 DESCRIPTION ACCOUNT CITY AMOUNT PLAN CHECK DEPOSIT- RESIDENTIAL 101-0000-42600 1 $1,200.00 Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $1,200.00 DESCRIPTION ACCOUNT CITY AMOUNT BACKFLOW DEVICE 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT BACKFLOW DEVICE PC 101-0000-42600 0 $5.34 DESCRIPTION ACCOUNT CITY AMOUNT BUILDING SEWER 101-0000-42401 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT BUILDING SEWER PC 101-0000-42600 0 $18.68 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $320.16 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $320.16 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $40.02 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT ROOF DRAIN 101-0000-42401 0 $106.72 DESCRIPTION ACCOUNT CITY AMOUNT ROOF DRAIN PC 101-0000-42600 0 $106.72 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $40.02 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT PC 101-0000-42600 ❑ $24.00 Total Paid for PLUMBING FEES: $1,048.52 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 DESCRIPTION I ACCOUNT I CITY I AMOUNT SMI - RESIDENTIAL I 101-0000-20308 1 0 $65.22 J Total Paid for STRONG MOTION INSTRUMENTATION SMI: $65.22 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($77.52) DESCRIPTION ACCOUNT CITY AMOUNT SINGLE FAMILY DETACHED 2018 UPDATE 224-0000-20320 0 $77.52 DESCRIPTION ACCOUNT CITY AMOUNT SINGLE FAMILY DETACHED 2018 UPDATE 224-0000-20320 0 $2,232.48 Total Paid for TUMF - RESIDENTIAL: $2,232.48 0"L(ra za PERMIT# 'EtS2_0 i8 . ®Cfl PLAN LOCATION: Project Address: S �l-1 l io Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: N2\J �irLS�t - wk 1•l �-Le Applicant Name: CT a 3 R LL L Address: 5,) 1 �'e lA 13 3 0 M E 1 P� s 'o \` City, ST, Zip: �.`V'� eser4 (A qZ 6o Telephone:( Email: l�l 1 1 w� �k Co Valuation of Project $ �✓1Ps .�� �c�C'� Contractor Name:�4 New SFD Construction: Address: �(� v ; V ert7 S Conditioned Space SF City, St, Zip v ` 4,i r �Z2 S Garage SF Telephone: +6 0 Z S L/ Patio/Porch SF Email: `— 6L n -�'� Vic 11� �r"t G��"" Fire Sprinklers SF State Lic: City Bus Lic: Property Owner's Name: Address: to `o 1 City, ST, Zip 1 1-, D� Pry Telephone: q72- Email: -� �] +1 Z LJ_ New Commercial / Tenant Improvements: Total Building SF -1 Z2 6 d Construction Type: Occupancy: 78495 CALLE TAMPICO LA QU I NTA, CA 92253 760-777-7000 Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 Kilt, MAR 0 8 2019 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: I COMMIIND. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS O;ITY Of, LA QUIN TA CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMINT (California Education Code 17620) Project Name: The Hideaway Date: March 8, 2019 Owner's Name: Ryan Thomas Project Address: 53-584 Via Palacio, LaQuinta Project Description: New SFD APN: 777-220-018 Tract #: Type of Development: Residential xx Commercial Total Square Feet of Building Area: 5,725 sq. ft. Phone No. 760-972-7504 Lot #'s: Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: March 4, 2019 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code 65995 5725 $3.79 $21697.75 Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement Building Permit Application Completed: Yes/No By: Larry Moen, Director Facilities Dev. & Planning Note: Pursuant to AB 181 any room additions or enclosures of 500 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within the same school district's jurisdiction are exempt from developer fees. 1 _ Certificate issued by: Laurie Howard, Administrative Spec. Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this -District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90-day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90-day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. 11/2010 pKr5 LDIS-041 LY) CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 9/25/2009 Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date: 0 /N/ 1 �1 Developer: K, 3 Z LL L Tract No. L'b " (6� Tract Name: �� �11QSN 4 f Lot No.(s): .2-I`Z PQP 1�-ZZ0 �df8 I Address(s): S 3S� `� V 4 1 J ejriJ Phone Number: The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the Building & Safety Department: ❖ CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4, #5 & #7 BELOW ❖ TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW ❖ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1. #2 #3 #5 & #7 BELOW ❖ WALLS SIGNS OTHER: PROVIDE ITEM #6 BELOW 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please withhold• green sheet submittal until a Pad Elevation Certificate can be provided. 2. Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils Engineer. Recently rough graded residential developments which have a previously approved geotechnical certification are exempt from this requirement. 3. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots. 4. Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 certification number is required. 5. Attach a copy of the rough or precise grading plan to the Public Works Department showing building location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain development plan. 6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. 7. Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW approved building construction projects require either a WQMP or a completed WQMP exemption form. Approved maps/plans may be viewed at the following link: htt :/�1www.1a ug inta.or /g PlanCheck/m search.aspx, I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff. Recomrnbnded.by: Date: Public Works Distribution: ( uI) Green Sheet to Building & Safety ( ) Green Sheet to Planning Department Declined for approval for reason(s) as follow(s), please correct and resubmit: T:\Checklists- Forms & Applications\Fors & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc Cjly,F,iof<<La,Quinta - PM10 Fugitive Dust Control Project Information Construction Phase PM10 Agreement 1<1 acre/lot or Infill Proiectl Project Information Project Contractor: l n o rx 5 Project Phase (check one) El Construction Demolition Project Name: KST 2-32- �/ Project Tract/Lot Numbers: TO. 0Zd - 160 /Tf ` "�I 'r^Z20 � 0IS �. \� Project Street Address: _55tL-1 V 16, YGI4C[� Total Acres in Active Construction (<1 acre per Lot): _ a Anticipated Start Date. U'� /,�,5! �L Anticipated Completion Date: 1 PM10 Contact Information Please note: Dust control is required 24 hours a day, 7 days a. week, regardless of construction status. Person listed below is responsible for dust control during business and non -business hours. ��an ` w1a yam► Name: Title: 0W ne(' Company Name: VST - 23 Z 1--L- �- Mailing Address: ° s v U4 �Q�ds 14 City, State, ZIP Code: IU��� L Zt44 �� r1Z253 Primary Phone M Fax M 24 Hour Emergency Phone#: '1 J 0 oil- 2- - L 1 Cell Phone �Tjb� /� ) T�� "L�Z T -_-) UL/ Email Address:n� _ PM10 Certificate #: �- L,0 3 '- OD The above stated owerty owner or authorized representative): ❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; ❖ Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. ❖ Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; ❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; ❖ Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes; ❖ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control plan or any City/County initiated abatement activities. Signature of Property Owner or Authorized Representative Date T:\Checklists - Forms & Applications\Forms & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doe RECORDING REQUESTED BY: DJT - 232 LLC AND WHEN RECORDED MAIL TO: DJT - 232 LLC Escrow No.: FS2623 A.P.N.: 777-220-018-4 TRA: 020-160 2018-0328503 08/15/2018 02:19 PM Fee: $ 92.00 Page 1 of 2 Recorded in Official Records County of Riverside Peter Aldana Assessor -County Clerk -Recorder 4 SPACE ABOVE THIS LINE IS FOR RECORDER'S USE GRANT DEED THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX IS $0.00 R&T Code Section 11911 [ X ] computed on full value of property conveyed, or [ ] computed on full value less value of liens or encumbrances remaining at time of sale. [ ] unincorporated area [ X ] City of La Quinta FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Christine de Clercq, A Single Woman hereby GRANT(S) to KJT-232 LLC, A California Limited Liability Company the following described real property in the County of Riverside, State of California See Exhibit "A" attached hereto and made a part hereof Commonly known as: 53232 Via Palacio (Lot 232) , La Quinta, CA 92253 Dated: August 2, 2018 A notary public or other officer completing this certificate 7 verifies only the identity of the individual who signed the _ document to which this certificate is attached, and not the _�- truthfulness, accuracy, or validity of that document. ~ Christine de Clercq STATE OF CALIF NIA. COUNTY OF 18 c On Zd k before me, a notary public, personally appea ed who proved to me on the basis of satisfactory evidence to be the person(s) whose name(eislare subscribed to the within instrument and acknowledged to me that helsWthey executed the same In hlsl /their authorized capaclty(!q and that by his/her/theirsignatureA on the instrument the personw, the entity upon behatf of which the person acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. ) SS. LEETA A. SLAMA Notary Public - California a Riverside County z Commission of 2171626 n M Comm. EK iris Nov 12. 2020 (Seal) Signature -3-�. _? (This area for official notary Iff1T MAIL TAX STATEMENTS AS DIRECTED ABOVE 4` V_ a FEB 2 4 CITY OF LA QuvyTA CC?blf VNIITY DEVELOPMENT DOC #2018-0328503 Page 2 of 2 EXHIBIT " A" PARCELI: LOT 232 OF AMENDED TRACT NO.29894-2, IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 327, PAGE(S) 56 THROUGH 88, INCLUSIVE OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. EXCEPTING THEREFROM TO GRANTOR, AND ITS SUCCESSORS AND ASSIGNS, INTEREST IN ALL WATER, MINERALS, OIL, GAS, PETROLEUM, OTHER HYDROCARBON SUBSTANCES AND ALL GEOTHERMAL ENERGY SOURCES IN OR UNDER SAID LAND OR WHICH MAY BE PRODUCED FROM SAID LAND. PARCEL2: NON-EXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, EGRESS, DRAINAGE, MAINTENANCE, REPAIRS AND FOR OTHER PURPOSES, ALL AS DESCRIBED IN THE DECLARATION. "END OF LEGAL DESCRIPTION' December 24, 2018 KJT — 232, LLC 73-399 El Paseo Drive, Suite 101 Palm Desert, CA 92260 Re: Lot 232 at 53584 Via Palacio Construction Document Review #1 Dear KJT — 232 LLC: This correspondence shall serve as notification that the Hideaway Design Review Committee (DRC) reviewed your construction document submittal as part of the December 18, 2018 meeting. The project was approved to move forward to the construction phase subject to the following comments being addressed. All comments must be addressed no later than January 29, 2019, for review at the February 5, 2019 meeting, or one -week prior to your request for a Pre - Construction Meeting (whichever comes first). The comments are as follows: 1. There appears to be discrepancies with regard to the site walls. The walls heights, and step-downs, are called out differently on the grading plans and other plan sheets. As a reminder, walls in the rear yard view corridors may not exceed 3' in height. (Ex: Sheet A1.2 and the Landscape plan show a 24" vs 32" wall shown on various sheets.) 2. The light fixture specification sheet provided was approved subject to bulbs being installed that are consistent with the guidelines. 3. The pool tile sample was approved subject to a matte finish being utilize where visible to public view. 4. Details and dimensions are required for the chimney caps to verify visual screening of the metal flues as well as other architectural detailing (ex. railing). 5. The door and window details do not appear to be consistent with the plans. The 6" minimum recessing must be provided on the appropriate doors and windows; however, in some areas (ex. Doors 8 & 10 and Window G) the walls do not appear to be 6" wide therefore the committee does not understand how the recess will be achieved. Please clarify. 6. The gate details don't match throughout the plan set. As the gates will not be visible, either design is acceptable but the plans must be updated to be consistent. 7. Courtesy comment: The irrigation details for the palms do not appear to be correct. 8. On sheet L-1 three trees appear to be mislabeled. 9. Courtesy comment: The plans will be easier to read if unnecessary layers are turned off (ex. difficult to read existing contours). 10. Please label the location of the steel edging as the symbol in the legend is unclear. 11. The committee suggestions changing the Agave Americana to Agave Weberii. In addition, changing the Euphorbia Millii that is located between the Agave, and along the walkway to the gate, to something less susceptible to reflected heat may help the survival of the plants. 12. The use of Equisetum hymale cannot be approved. RECiII FEB 2 7 ;d4 0 CITY OF LA QUINTA COMMUNITY DEVELOPMENT 13. Courtesy comment: The use of Morea Iris, as proposed in full sun, may not be a suitable selection. The committee suggests the use of Dianella as an alternate. The use of Asparagus Meyerii, as proposed in the courtyard, may also be problematic. 14. The Tehevitia peruviana should be noted as a standard in the plant legend which will provide a tree form. 15. Please clarify the type of Lemon proposed and if both grapefruit trees are meant to be pink. 16. Courtesy comment: Please consult with CVWD regarding water requirements, appropriate sizing of real turf lawns, etc. 17. The irrigation plan typically calls out lateral lines, emitter locations, etc. 18. The fire pit detail indicates sand as the backfill instead of 1/4" gravel. Please clarify if this is the intent. 19. Please clarify the definition of "native soil mixture" to be utilized as a back fill. 20. Detail M: Please submit the pot details and specifications for review. 21. Please provide a detail illustrating the sub -meter connection and flow sensor per CVWD's requirements. 22. Gerry Tarsitano, on behalf of the Golf Club, must review any off -property grading or planting proposed. In addition, any approved extensions must transitional appropriately to the neighboring properties and the golf course. Please contact Brook Marshall at 760-219-8057 or by email at DRCFacilitator@gmaii.com with any questions or to schedule your Pre -Construction Meeting once a Building Permit has been obtained. As a reminder, no preparatory work can be done on site prior to the Pre -Construction Meeting being held. Sincerely, THE HIDEA WA Y DESIGN RE VIE W COMMITTEE By: Title: cc: James Ciofri Gustavo Magana DRC File 1114 KLEY - iR Date: Pursuant to Cal. Civil Code. any rejection by the DRC may be appealed to the Board of Directors for the Association. If you ivish to pursue an anipal- nlease contact the Association's ❑mnerl)P Ina+xrRer d1r er dy. Water Qualitv Manaaexnent Plan (WQMP) Exemption Form - Whitewater River Region Documentation of Project Not Requiring a WQMP but Requiring Site Design BMPs and Source Control BMPs by Entitlement Conditions of Approval or Permit Conditions — WQMP Required for the Listed Change of Land Uses or for Changes of Pollutant Stream (All Questions Below Must be Answered "No" To Exempt Project), Yes No Entitlement or construction of new single-family hillside residence(s) that create 10,000 square feet, or more, of impervious area where the re-develo ment natural slope is 25% or greater? El 0 j Entitlement or construction of new single-family hillside residence(s) that create 10,000 square feet, or more, of impervious area where the pre -development natural slope is 10% or greater where erosive soil conditions are known? ❑ Entitlement or construction of new commercial and industrial development(s) of 100,000 square feet or more? ❑ ❑ Entitlement or construction of new automotive repair shop(s) including body, upholstery, paint, exhaust, tire, transmission, engine or other automotive specialty repair. [Standard Industrial Classification (SIC) codes 5013, 7532, 7533, 7534, 7537, 7538, and 7539]? ❑ Entitlement or construction of new retail gasoline outlet(s) disturbing greater than 5,000 square feet? ❑ Entitlement or construction of new restaurant(s) (or potential restaurant shell space) disturbing greater than 5,000 square feet?� ❑ Entitlement of construction of new home subdivisions with 10 or more housing units? ❑ �I Entitlement or construction of new parking lot(s) of 5,000 square feet or more, or with 25 or more parkingspaces, and potentiallyexposed to Urban Runoff? ❑ Applicant Information Name and Title , -> "I er Company Z ILL Phone G Z -4�;DR- Email _ Project Information Project Name Type (SFH,_M_ ulti-Family, Commercial, Etc.) Location or Street Address 4 ° d Nearest Cross Streets Wtdt Municipality/County/Zip Code La Quinta Tract Number(s) and/or Assessor Parcel Number(s) Q"Lp - Ito Af :+1-J -22© " a (-, Other Location Information Watershed Whitewater River Source Control BMP Information Size of Project Area (nearest 0.1 acre) 0 -4 Project Area managed with Site Design or Low Impact Development (LID) BMPs (nearest 0.1 acre) Is the project subject to onsite retention by City ordinance or policy? Name of the Entity that will implement, operate, andT maintain the Source Control BMPs Z3Z �L G Contact Name A Street or Mailing Address { j ie� 4 elvSS City LAQlI1'n. q Zip Codes Phone Z T:\Checklists - Forms & Applications\Forms & Applications\GREEN SHEET cover & PM10less than 1 Acre Revised 9-25-09 doc Check item To be Performed source Control BMP Requirements -All Projects Require Non -Structural BMP Source Control Non -Structural BMP (See Appendix H, Section 4.5.2.1) Ongoing Irrigation System and Landscape Maintenance Ongoing Litter Control Ongoing Drainage System Inspection & Maintenance Education/Training for Property Owner, Operators, Occupants, or Employees Activity Restrictions — Prohibition of Debris Blowing/Sweeping/Washing into Street/Storm Drain, Closed Trash Lids, Restriction of Vehicle Washing Ongoing Street Sweeping at Private Streets and Private Parking Lots Check Item To be Provided Source Control BMP Requirements — Small Sloped Lots, Small Commercial, <10 Unit Subdivisions, <5,000 Square Ft. Parking Lots, Etc. Structural BMP (See Appendix H, Section 4.5.2.2) Storm Drain Inlet Stenciling and Signage Landscape and Irrigation System Design to Minimize Erosion & Nuisance Runoff Protection of Slopes and Channels to Minimize Erosion Multi -Family Project Use of Community Car Wash Racks Wash Water Controls for Food Preparation Areas to Use SanitarySewer Fueling Area (Design & Maintenance) Including PCC Surface, Canopy & Spill Prevention Air/Water Supply Area Drainage (Design & Maintenance) Including Spill Area Containment Trash Storage Areas (Design & Maintenance) Including Attached Lids, Storm Water Controls ❑ Loading Docks (Design & Maintenance) Including Storm Water Controls, Dry & Frequent Cleaning Procedures Maintenance Bays (Design & Maintenance) Including Indoor Location & Storm Water Containment Vehicle and Equipment Wash Areas (Design & Maintenance) Including Canopy & Containment Outdoor Material Storage Areas (Design & Maintenance) Including Canopy & Containment Outdoor Work Areas or Processing Areas (Design & Maintenance) Including Canopy & Containment ❑ CC&R's, Maintenance Agreements or Other mechanisms will be used to ensure the ongoing operation, maintenance, funding, transfer and implementation of the project -specific WQMP requirements. Legal description and plat stamped by Registered Surveyor to be attached to the applicable CC&R or Maintenance Agreement for recordation at Riverside County. (Optional Requirement to be reviewed on a Project by Project basis) _ BMP Acknowledgement The applicant shall comply with listed BMPs and applicable provisions of the City's NPDES stormwater discharge permit, LQMC Sections 8.70.010 et seq. (Stormwater Management and Discharge Controls), and 13.24.170 (Clean Air/Clean Water); Riverside County Ordinance No. 457; the California Regional Water Quality Control Board — Colorado River Basin Region Board Order No. R7-2008-0001 and the State Water Resources Control Board's Order No. 99-08-DWQ. Signature: nJ Print Name: ►` 1� / '� `6 Phone: j) ) ` -► Z :7�/ TAChecklists - Forms & Applications\Forms & Applications\GREEN SHEET cover & PM10less than 1 Acre Revised 9-25-09 doc Applicant Certification I certify that I have read this form in its entirety and understand the City's submittal and review process and the requirements for this form. I understand and agree that if during the processing of the form, it is determined the information contains errors or omissions, clarification and/or supplemental information may be required and the preparation of such information may be considered, in the Community Development Director's judgment, an unreasonable delay and will result in a suspension of processing time limits in accordance with the California Code of Regulations, Title 14, Section 15109. Signature: Print Name: Title: owel VI �.f Date: / I C/ Phone: ( _-tb# ) `Tz- Owner Certification I certify under the penalty of the laws of the State of California that I am the property owner of the property that is the subject matter of this application and I am authorizing and hereby do consent to the filling of this application and acknowledge that the final approval by the City of La Quinta, if any, may result in restriction, limitations and construction obligations being imposed on this real property. Signature:A_ Print Name: t, Phone: (�Mq ) Building Permit Number: 312,e " 20 t - y (ib Project Description: SFR Exempt: ❑ (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Plan Submittal Datel Job Site Address) Owner's Name Number, Street, or PO Box City, State, Postal Code Owner's Phone Number Owner's E-Mail Address Project Manager's Project Manager's Phone N Project Manager's E-mail A Builder / Contractor Number, Street or PO Box City, State, Postal Code 2/12/2019 53584 Via Palacio KJT 232 LLC 76245 Via Saturnia Indian Wells, CA. 92210 760-972-7504 Ryan Thomas 760-972-7504 an l'miI_Iw�rk.com KJT 232 LLC 76245 Via Saturnia Indian Wells, CA, 92210 Project Square Footagel Approx. 5,700 scl ft A CityApproval By Renado Gouldlock•DEC/BurrteC waste` Date of City Approval 0 / 2J 19 Materials To Be Discarded: Product Tons Trash 23.50 Not recyclable Asphalt 0.00 Recyclable Brick/Block 000 Recyclable Cardboard 0.00 Recyclable Commingled 0.00 Recyclable Concrete 25.00 Recyclable Drywall 2.90 Recyclable Donated / Reuse* 0.00 Recyclable *Describe Items REQ-412Ue FEB 2 7#09,-a�U CITY OF !A QUINTA COMMUNITY DEVELOPMENT Product Tons Masonry (broken) 0.00 Plaster 6.75 Scrap Metal 0.00 Tile (floor) 0.60 Tile (roof) 0.75 Wood 10.50 Landscape Debris 0.00 Totals: Recycle Trash Projected Diversion: 46.5 L 23.5 66.43% I understand it Is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (OMP) for the above named project shall guarantee that at least 65% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property owner(s) and the owner retains tegal responsibility for ensuring that Ih a of the OMP are adhered to. The property owner(s) and general contractor shall be kept Informed of the diversio r§Q0 bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved c . 6rvr Irant;fer :. j Owner /Developer /Project Manager / Superintendant Date 0 7� f CIYY �.;, %i IA T44f 4 4aum& P.O. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT (760)777-7012 FAX (760) 777-7011 PROPERTY OWNER'S PACKAGE Disclosures & Forms for Owner -Builders Applying for Construction Permits IMPORTANT! NOTICE TO PROPERTY OWNER Dear Property Owner: An application for a building Penrut, has b en sub ed, . in your name listing yourself as the builder of the property improvements specified at�(���U tYA.1 We are providing you with an Owner -Builder AcknowIedgn_ie and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority, OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION DIRECTIONS: Read and initial each statement below to signs you understand or verb this information. fZ 1, I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. �L2. I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. _&t 3. I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. 4.1 understand Contractors are required bylaw to be licensed and bonded in California and to list their license numbers on permits and contracts. Ar 5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value Of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. "(5. 1 understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers, compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. 7�I understand under California Contractors' State License Law, an Owner -Builder who builds dential structures cannot legally build them with the intent to offer them for sale, unless all work is Performed 1 byesilicensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor, ST -8. I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. 9. I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, -the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1- 800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. h�l 0. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the party legally 4nd fi nc1 Ily r onsihle f r prq osed construction activity at the following address: :a M1- 11. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner -Builders as mell as employers. f12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature. Signature of property owner Date: Note: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: Name of Authorized Agent: T Address of Authorized Agent: Tel No I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owners signature. Property Owner's Signature: Date: L L L .� 117 CITY OF LA QUINTA SUB -CONTRACTOR LIST JOB ADDRESS `' 1� Cil���� PERMIT NUMBER ��j ��ZC7lf -- QyI OWNER! �� �Z. L LL ( _ a BUILDER This form shall be posted on the job with the Building Inspection Card at all ti_rnes in a_ conspicuous place. Only persons appearing on this list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance of building Dermit. For each aDDlicable trade. all information reouested below must be completed by aDDlicant. "On File" is not an acceptable response. Trade 1 Classification Carztra, ter. State Contractor's.-L.icei�se Workers -Comp rls�tion.ir�su.:r ncg; C:.it.. 6usines$. License Company Name Classification (e.g. A, B, C-8) License Number (xxxxxx) Exp. Date (xx/xx/xx) Carrier Name (e.g. State Fund, CalComp) Policy Number (Format Varies) Exp. Date (xx/xx/xx) License Number (xxxx) Exp. Date (xx/xx/xx) EARTHwotzx (c-12) �,, r� ti �` "° `'�3�0 V— ��s�' �1'�`�-i 3'� +'J12 1� �l�t2z b.�11Q .-CONCRETE (C-s) q44 3 40-O' � Z��Z� ;-�I � ,FRAMING(C-5) � r ? �[I'rW�i ', 1 1 J i�6�7! �" �Qr4J4 STRU:CT. STEEL (C-511: MASONRY (C-29) LIMB.ING OCT, �� ,..� � vC -vt LATH, PL..ASTE..R: (:C=35): DRYWALL (C-9.) :.HVAC (C 20) bcq r�s 4C d 84 -7`' (-2-0 GA 1©A?KV��'T��.� -ELECTRICAL (C-10) 17%A91 Dec-�W c l L2 v v33i 2=' Pkf�1-J l �11; �f' Z to ' Z!!J) 20 ROOFING (C-39) SHEET:WTAL. (C-43): FLOORING (.C-1:5). GLAZING (.C-17) INSULATION (C-2) SEWAGE DISP. (G42): PAINTING• fG-3-3) CERAMIC TILE (.C=54) CABINETS (C•S) FENCING (C-13) LA.ND.S.CAPING (C-27) POOL (C-53) BUILDING ENERGY ANALYSIS REPORT RECEIVED FEB 81N 'rry QF to ouffrA COM10"M [DE!,ELO P140T PROJECT: Residence The Hideaway KJT232 La Quinta, CA 9225 Project Designer: cam{ CITY OF LA QUINTA BUILDING DIVISION LC REVIEWED FOR CODE COMPLIANCE DAT 1 ))INKY �• $QG52.d16 — csi1$ Cioffi Architect 2121 E Tahquitz Canyon Palm Springs, CA 92262 (760) 325-1557 Report Prepared by: Jon d. Scott Scott Design and Title 24, Inc, 74818 Velie Way Suite 8 Palm Desert, CA 92260 (760) 200-4780 Job Number: Date: 12/19/2018 REVIEWED MAR 21 2019 TRI LAKE CONSULTANTS, INC. RECEIVED r,z MAR 41 2019 CONSULTING�G7. ROUP The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. I TABLE OF CONTENTS 1 Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01 -E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 16 Form MF-1 R Mandatory Measures Summary 18 HVAC System Heating and Cooling Loads Summary 22 Zone Load Summary 97 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: KJT232LLC Calculation Date/Time: 08:40, Wed, Dec 19, 2018 Calculation Description: Title 24 Analysis Input File Name: Hideaway KJT232LLC-Cioffi-18.ribd16x CFI R-PRF-01 Page 1 of 13 GENERAL INFORMATION 01 Project Name KJT232LLC 02 Calculation Description Title 24 Analysis 03 Project Location The Hideaway KJT232LLC 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ftZ) 5725 15 Number of Zones 5 16 Slab Area (ftZ) 4941 17 Number of Stories 2 18 Addition Cond. Floor Area(ft2) n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ftZ) n/a 21 Glazing Percentage (%) 23.0% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ftZ-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 1.66 1.94 -0.28 -16.9% Space Cooling 95.71 91 26 4.45 4.6% IAQ Ventilation 1.73 1.73 0.00 ° Water Heating 2.87 2.47 0.40 1 y 47/4 Photovoltaic Offset — 0.00 0.00 — Compliance Energy Total 101.97 n97.40 4.57 ` 4.5% DEC 21 ZV 1N T rR1%,'EST CONSUL-VtiNG GROUP Registration Number: 218-Po1033287OA-000-000-0000000-0000 Registration Date/Time: 2018-12-19 08:45:01 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 CITY OF LA QUINTA COMMUNITY DEVELOPMENT HERS Provider CaiCERTS inc. Report Generated at: 2018-12-19 08:41:50 (/P sexri�. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: KJT232LLC Calculation Date/Time: 08:40, Wed, Dec 19, 2018 Page 2 of 13 Calculation Description: Title 24 Analysis Input File Name: Hideaway KJT232LLC-Cioffi-18.ribd16x ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energ y gy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen 9� 70 Notes EDR of Standard Efficiency 57.0 EDR of Proposed Efficiency EDR Value of Proposed PV + Battery 55.2 0.0 Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. Final Proposed EDR 55.2 Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified. PV Generation EDR PV size limit may violate REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • --None -- Registration Number: 218-Po1033287oA-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2018-12-19 08:45:01 Report Version - CF1 R-11302018-1149 HERS Provider: CaICERTS inc. Report Generated at: 2018-12-19 08:41:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: KJT232LLC Calculation Date/Time: 08:40, Wed, Dec 19, 2018 Calculation Description: Title 24 Analysis Input File Name: Hideaway KJT232LLC-Cioffi-18.ribd16x BUILDING - FEATURES INFORMATION 01 02 03 f 04 05 Project Name 2 Number of Dwelling 1 Conditioned Floor Area (ft) Units Number of Bedrooms Number of Zones KJT232LLC 5725 1 20 5 ZONE INFORMATION 01 02 03 Zone Name Zone Type HVAC System Name casita Conditioned HVAC casita1 master Conditioned HVAC mstr2 Great room Dining Conditioned HVAC grt3 bedroom Conditioned HVAC bed4 second Conditioned HVAC 2nd5 06 Number of Ventilation Cooling Systems 0 CFI R-PRF-01 Page 3 of 13 07 Number of Water Heating Systems 1 04 07 ater Heating System 1 Water Heating System 2 DHW Sys 1 n/a U(fft,2 q06 DHW Sys 1 n/a DHW Sys 1 n/a DHW Sys 1 n/a DHW Sys 1 n/a Registration Number: 218-Po1033287oA-000-000-0000000-0000 Registration DateTme: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-114918 12 1 s os:a5:o1 HERS Provider: CaICERTS inc Report Generated at: 2018-12-19 08:41:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: KJT232LLC Calculation Date/Time: 08:40, Wed, Dec 19, 2018 Calculation Description: Title 24 Analysis Input File Name: Hideaway KJT232LLC-Cioffi-18.ribd16x OPAQUE SURFACES 01 Name N Wall R21 E wall R21 S Wall R21 W Wall R21 Interior Surface R-38 Radiant UnVntR19 N Wall R21 2 E wall R21 2 S Wall R21 2 W Wall R21 2 Interior Surface 2 R-38 Radiant UnVntR19 2 N Wall R21 3 E wall R21 3 S Wall R21 3 W Wall R21 3 Interior Surface 3 R-38 Radiant UnVntR19 3 N Wall R21 4 E wall R21 4 S Wall R21 4 W Wall R21 4 Interior Surface 4 R-38 Radiant UnVntR19 4 N Wall R21 5 E wall R21 5 S Wall R21 5 W Wall R21 5 Interior Surface 5 R-38 Radiant UnVntR19 5 02 Zone casita casita casita casita casita casita master master master master master master Great room Dining Great room Dining Great room Dining Great room Dining Great room Dining Great room Dining bedroom bedroom bedroom bedroom bedroom bedroom second second second second second second Registration Number: 218-P010332870A-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance 03 Construction R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-0 WALL R-38 Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-0 WALL R-38 Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-0 WALL R-38 Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-0 WALL R-38 Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-0 WALL R-38 Attic 04 Azimuth 10 100 190 280 n/a n/a 10 100 190 280 n/a n/a 10 100 190 280 n/a n/a 10 100 190 280 n/a n/a 10 100 190 280 n/a n/a 05 FOrientation specify - specify specify - ��ssp�ecify n/a n/a - specify - - specify - - specify - - specify - n/a n/a specify - - specify - - specify - specify - n/a n/a - specify - - specify - specify - - specify - n/a An/a Registration DateMme: 2018-12-19 08:45:01 Report Version - CF1 R-11302018-1149 CF1 R-PRF-01 Page 4 of 13 06 07 08 Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) 264 24 90 196 16 90 82 0 90 264 72 90 503 0 n/a 503 n/a n/a 375 0 90 268 211 90 82 0 90 190 0 90 366 0 n/a 1200 n/a n/a 380 40 90 870 440 90 380 90.9 90 380 1033 90 503 0 n/a 2435 n/a n/a 280 79 90 82 0 90 280 78 90 82 0 90 503 0 n/a 803 n/a n/a 460 37.8 90 460 46 90 460 18.9 90 460 82.5 90 455 0 n/a 784 n/a n/a HERS Provider: CaICERTS inc Report Generated at: 2018-12-19 08:41:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: KJT232LLC Calculation Date/Time: 08:40, Wed, Dec 19, 2018 Calculation Description: Title 24 Analysis Input File Name: Hideaway KJT232LLC-Cioffi-18.ribd16x ATTIC 01 Name Attic casita Attic master Attic Great room Dining Attic bedroom Attic second 02 Construction Attic Roofcasita Attic Roofmaster Attic RoofGreat room Dining Attic Roofbedroom Attic Roofsecond 03 Type Unventilated Unventilated Unventilated Unventilated Unventilated 04 Roof Rise 3 3 3 3 3 05 Roof Reflectance 0.1 0.1 0.1 0.1 0.1 O6 Roof Emittance 0.85 0.85 0.85 0.85 0.85 07 Radiant Barrier Yes Yes Yes Yes Yes CF1 R-PRF-01 Page 5 of 13 08 Cool Roof No No No No No Registration Number: 218-Po1033287oA-000-000-0000000-0000 Registration DateRme: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-114918 12 1 s oe:as:o1 HERS Provider: Ca:inc. Report Generated at: 2018-12-19 08:41:5041:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: KJT232LLC CF1R-PRF-01 Calculation Date/Time: 08:40, Wed, Dec 19, 2018 Page 6 of 13 Calculation Description: Title 24 Analysis Input File Name: Hideaway KJT232LLC-CiofB-18.ribd16x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Height Surface (Orientation -Azimuth) Width (ft) (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading 13 Window N Wall R21 (-specify --10) -- 1 24.0 0.42 0.25 Insect Screen (default) V Window E wall R21 (-specify - 100) -- --- 1 16.0 0.42 0.25 Insect Screen (default) O Window W Wall R21 (- specify --280) -- 1 24.0 0.42 0.25 Insect Screen (default) P Window W Wall R21 (- specify --280) - - - 1 24.0 0.42 0.25 Insect Screen (default) O Window W Wall R21 (- specify --280) -- - 1 24.0 0A2 0.25 Insect Screen (default) E Window E wall R21 2 (- specify - 100) ---- - 1 51.0 0.42 0.25 Insect Screen (default) 7 Window E wall R21 2 (-specify - 100) -- - 1 160.0 0.42 0.25 Insect Screen (default) F Window N Wall R21 3 (-specify - 10) -- -- 1 40.0 0.42 025 Insect Screen (default) 8 Window E wall R21 3 (- specify --100) --- - 1 240.0 0.42 0.25 Insect Screen (default) G Window E wall R21 3 (- specify --100) -- 1 40.0 0.42 0.25 Insect Screen (default) 10 Window E wall R21 3 (-specify --100) -- 1 160.0 0.42 0.25 Insect Screen (default) 9 Window S Wall R21 3 (- specify --190) --- 1 48.0 0.42 0.25 Insect Screen (default) H Window S Wall R21 3 (- specify - 190) - -- 1 6.3 0.42 0.25 Insect Screen (default) J Window S Wall R21 3 (- specify -190) - 1 6.3 0.42 0.25 Insect Screen (default) K Window S Wall R21 3 (-specify --190) - -- 1 Insect Screen (default) L Window S Wall R21 3 (-specify --190) .25 Insect Screen (default) 1 Window W Wall R21 3 (- specify --280) - -- 1 .25 Insect Screen (default) T Window N Wall R21 4 (- specify --10) - 1.25 %4225.25 Insect Screen (default) 15 Window N Wall R21 4 (- specify --10) --- -- 1 425 Insect Screen (default) U Window N Wall R21 4 (- specify --10) - -- 125 Insect Screen (default) M Window S Wall R21 4 (- specify - 190) - - 1 15.0 0.42 0.25 Insect Screen (default) 11 Window S Wall R21 4 (- specify --190) -- 1 48.0 0.42 0.25 Insect Screen (default) N Window S Wall R21 4 (-specify -A 90) -- -- 1 15.0 0.42 0.25 Insect Screen (default) W Window N Wall R21 5 (- specify --10) -- -- 1 6.3 0.42 0.25 Insect Screen (default) X Window N Wall R21 5 (- specify --10) - - 1 6.3 0.42 0.25 Insect Screen (default) Y Window N Wall R21 5 (- specify --10) -- 1 6.3 0.42 0.25 Insect Screen (default) Z Window 1 N Wall R21 5 (- specify --10) E4�_ 6.3 0.42 0.25 Insect Screen (default) AA Window N Wall R21 5 (- specify - 10) - 1 6.3 0.42 0.25 Insect Screen (default) BB Window N Wall R21 5 (-specify --10) --- 1 6.3 0.42 0.25 Insect Screen (default) Registration Number: 218-P01033287oA-000-000-0000000-0000 Registration Date/Time: 2018-12-19 08:45:01 HERS Provider: A Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 CaICERTS inc. Report Generated at: 2018-12-19 08:41:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: KJT232LLC METHOD Calculation Description: Title 24 Analysis Calculation Date/Time: 08:40, Wed, Dec 19, 2018 CF1R-PRF-01 Input File Name: Hideaway KJT232LLC-Cioffi-18.ribd16x Page 7 of 13 CC 1 Window E wall R21 5 (- specify --100 --- 35 Window) E wall R21 5 (- specify -•100) 1 12.5 0.42 0.25 Insect Screen (default) DID Window E wall R21 5 specify --100) (- 1 21 0 0.42 , 0.25 Insect Screen (default) EE Window S Wall R21 5 (- specify •-190) _ 12.5 __ 0.42 0.25 Insect Screen (default) FF Window S Wall R21 5 specify (- P fy -• � 90) __ 1 6.3 ____ 0.42 0.25 Insect Screen (default) GG Window S Wall R21 5 (- specify --190) _ 1 6.3 _ 0.42 0.25 Insect Screen (default) HH Window W Wall R21 5 (- specify --280) 1 6.3 ___ 0.42 0.25 Insect Screen (default) Window W Wall R21 5 (- specify --280) __ 1 6.3 0.42 0.25 Insect Screen (default) KK Window W Wall R21 5 (- specify --280) 1 63 0.42 0.25 Insect Screen (default) LL Window W Wall R21 5 (- specify --280) ` 1 6.3 _ 0.42 0.25 Insect Screen (default) MM Window W Wall R21 5 (- specify --280) ` - 1 6.3 0.42 0.25 Insect Screen (default) 34 Window W Wall R21 5 (- specify --280) '- 1 6.3 1 ____ 0.42 0.25 Insect Screen (default) ' Window W Wall R21 5 (- specify --280) 1 24.0 ____ 0.42 0.25 Insect Screen (default) OPAQUE DOORS 1 27.0 0.42 0.25 Insect Screen (default) 01 02 Name 03 04 Side of Building Door15 W Wall R21 3 Area ft2 ( ) U-factor 20.1 0.50 Registration Number: 218-Po1033287oA-000-000-0000000-0000 Registration DateMme: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-114918 12 1 s 08:45:01 HERS Provider: CaICERTS inc Report Generated at: 2018-12-19 08:41:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: KJT232LLC CF1 R-PRF-01 Calculation Date/Time: 08:40, Wed, Dec 19, 2018 Calculation Description: Title 24 Analysis Input File Name: Page 8 of 13 Hideaway KJT232LLC-Cioffi-18.ribdl6x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Construction Name Surface Type Construction Type Framing Total Cavity R-value F'�W�inter Design U-factor Assembly Layers • Under Roof Joists: R-6.0 insul. 2x4 Top Chord of Roof Truss @ 24 • Cavity/Frame: R-13.0/2x4 Top Chrd Attic Roofcasita Attic Roofs Wood Framed Ceiling in O.C. R 19 0.052 Roof Deck: Wood Siding/sheathing/decking Roofing: Light Roof (Asphalt Shingle) Ceilings (below Inside Finish: Gypsum Board R-38 Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 • Cavity / Frame: R-9 1 / 2x4 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.048 Insulation: R5 ExhteriorFinish. 3 Coat Stuccoeathing • Inside Finish: Gypsum Board R-0 WALL Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.277 • Cavity/Frame: no insul. /2x4 Other Side Finish: Gypsum Board • Under Roof Joists: R-6.0 insul. 7Attic 2x4 Top Chord of Roof Truss @ 24 • Cavity/Frame: R-13.0/2x4 Top Chrd Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.052 Roof Deck., Wood Siding/sheathing/decking Roofing: Light Roof (Asphalt Shingle) • Under Roof Joists: R-6.0 insul. Attic RoofGreat room Dining Attic Roofs Wood Framed Ceiling 2x4 Top Chord of Roof Truss @ 24 in. O.C. • Cavity/Frame. R-13.0/2x4 Top Chrd Roof Deck: Wood Siding/sheathing/decking R 19 0.052 Roofing: Light Roof (Asphalt Shingle) • Under Roof Joists: R-6.0 insul. Attic Roofbedroom Attic Roofs Wood Framed Ceiling 2x4 Top Chord of Roof Truss @ 24 in. O.C. • Cavity/Frame: R-13.0/2x4 Top Chrd Roof Deck: Wood Siding/sheathing/decking R 19 0.052 Roofing: Light Roof (Asphalt Shingle) • Under Roof Joists: R-6.0 insul. Attic Roofsecond Attic Roofs Wood Framed Ceiling 2x4 Top Chord of Roof Truss @ 24 in. O.C. • Cavity/Frame: R-13.0/2x4 Top Chrd Roof Deck: Wood Siding/sheathing/decking R 19 0.052 Roofing., Light Roof (Asphalt Shingle) Registration Number: 218-P010332870A-000-000-0000000-0000 Registration Date/Time: 2018-12-19 08:45:01 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-19 08:41:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: KJT232LLC Calculation Date/Time: 08:40, Wed, Dec 19, 2018 Calculation Description: Title 24 Analysis Input File Name: Hideaway KJT232LLC-Cioffi-18.ribd16x SLAB FLOORS 01 Name Slab -on -Grade Slab -on -Grade 2 Slab -on -Grade 3 Slab -on -Grade 4 BUILDING ENVELOPE - HERS VERIFICATION 01 Quality Insulation Installation (QII) Required WATER HEATING SYSTEMS 01 Name DHW Sys 1 WATER HEATERS 01 02 03 Heater Element Name Type DHW Heater 1 1 Gas CF1 R-PRF-01 Page 9 of 13 02 ! 03 04 + 05 06 07 Zone Area (ft) Perimeter (ft) TEdge Insul. R-value & Depth Carpeted Fraction Heated casita 503 75 None 0.8 No master 1200 68 None 0.8 No Great room Dining 2435 155 None 0.8 No bedroom 803 55 None 0.8 No 02 03 04 Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required n/a 02 03 04 05 06 System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Standard DHW Heater 1 (1) 1 0% Tank Type Small Instantaneous 04 05 06 07 08 09 10 11 12 Input Rating / Tank Standby Tank Uniform Energy Pilot / Insulation Loss / First Hour NEEA Heat Pump Tank Location Number Volume Factor / Energy Thermal R-value Recovery Rating / Brand / Model / or Ambient of Ugits (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Other Condition 1-F 07- 0.95 EF <= 200 kBtu/hr R-0/R-0 ' 0 n/a n/a fE n/a V Registration Number: 218-P010332870A-000-000-0000000-0000 Registration DateMme: 2018-12-19 08:45:01 HERS Provider. CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-19 08:41:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: KJT232LLC Calculation Date/Time: 08:40, Wed, Dec 19, 2018 Calculation Description: Title 24 Analysis Input File Name: Hideaway KJT232LLC-Cioffi-18.ribd16x C F1 R-PRF-01 Page 10 of 13 SPACE CONDITIONING SYSTEMS 01 02 03 04 I 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC casital Heat Pump Heating and Cooling System Heat Pump System 1 Heat Pump System 1 HVAC Fan 1 Air Distribution System 1 HVAC mstr2 Heat Pump Heating and Cooling System Heat Pump System 2 Heat Pump System 2 HVAC Fan 2 Air Distribution System 2 HVAC grt3 Heat Pump Heating and Cooling System Heat Pump System 3 Heat Pump System 3 HVAC Fan 3 Air Distribution System 3 HVAC bed4 Heat Pump Heating and Cooling System Heat Pump System 4 Heat Pump System 4 HVAC Fan 4 Air Distribution System 4 HVAC 2nd5 Heat Pump Heating and Cooling System Heat Pump System 5 Heat Pump System 5 HVAC Fan 5 Air Distribution System 5 HVAC - HEAT PUMPS 01 02 03 04 I 05 06 07 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor' Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 1 SplitHeatPump 1 7.7 35500 21300 16 12.5 Not Zonal Single Speed Heat Pump System 1-hers-cool Heat Pump System 2 SplitHeatPump 1 7.7 35500 21300 16 12.5 Not Zonal Single Speed Heat Pump System 2-hers-cool Heat Pump System 3 SplitHeatPump 1 7.7 35500 21300 16 12.5 Not Zonal Single Speed Heat Pump System 3-hers-cool Heat Pump System 4 SplitHeatPump 1 7.7 35500 21300 16 12.5 Not Zonal Single Speed Heat Pump System 4-hers-cool Heat Pump System 5 SplitHeatPump 1 7.7 35500 21300 16 12.5 Not Zonal Single Speed Heat Pump System 5-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Heat Pump System 1-hers-cool Required 350 Required Required Required Heat Pump System 2-hers-cool Required 350 Required Required Required Heat Pump System 3-hers-cool Required 350 Required Required Required Heat Pump System 4-hers-cool Required 350 Required Required Required Heat Pump System 5-hers-cool Required 350 Required Required Required Registration Number: 218-P010332870A-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration DateMme: 2018-12-19 08:45:01 Report Version - CF1 R-11302018-1149 HERS Provider: CaICERTS inc. Report Generated at: 2018-12-19 08:41:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: KJT232LLC Calculation Date/Time: 08:40, Wed, Dec 19, 2018 Calculation Description: Title 24 Analysis Input File Name: Hideaway KJT232LLC-Cioffi-18.ribdl6x CF1 R-PRF-01 Page 11 of 13 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1-hers-dist Air Distribution System 2 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 2-hers-dist Air Distribution System 3 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 3-hers-dist Air Distribution System 4 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 4-hers-dist Air Distribution System 5 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 5-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 2-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 3-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 4-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 5-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2-hers-fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3-hers-fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4-hers-fan HVAC Fan 5 Single Speed PSC Furnace Fan 0.58 HVAC Fan 5-hers-fan Registration Number: 218-PO1033287OA-000-000-0000000-0000 Registration DateMme: 2018-12-19 08:45:01 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-19 08:41:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: KJT232LLC Calculation Date/Time: 08:40, Wed, Dec 19, 2018 Calculation Description: Title 24 Analysis Input File Name: Hideaway KJT232LLC-Cioffi-18.ribd16x CF1 R-PRF-01 Page 12 of 13 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 HVAC Fan 2-hers-fan Required 0.58 HVAC Fan 3-hers-fan Required 058 HVAC Fan 4-hers-fan Required 0.58 HVAC Fan 5-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 215 0.25 Default 0 Required Registration Number: 218-Po1033297OA-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2018-12-19 08:45:01 Report Version - CF1 R-11302018-1149 HERS Provider: CaICERTS inc. Report Generated at: 2018-12-19 08:41:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: KJT232LLC Calculation Description: Title 24 Analysis Calculation Date/Time: 08:40, Wed, Dec 19, 2018 Input File Name: Hideaway KJT232LLC-Cioffi-18.ribd16x Page 13 of 13 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott''�� Company: Signature Date: Scott Design and Title 24, Inc. 2018-12-19 08:45:01 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance ate consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application Responsible Designer Name: Responsible Designer Signature Tim Scott Company: Date Signed: Scott Design and Title 24, Inc. 2018-12-19 08:45:01 Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. FEE 0 t Easy to Verify at CaICERTS.com Registration Number: 218-Po1033287oA-000-000-0000000-0000 Registration Date/Time: 2018-12-19 08:45:01 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 HERS Provider: CaICERTS inc. Report Generated at: 2018-12-19 08:41:50 RESIDENTIAL MEASURES SUMMARY Project Name Residence Building Type 10 Single Family C7 Addition Alone Project Address — — — ❑ Multi Family ❑ Existing+ Addition/Alteration — date ate 12/19/2018 The Hideaway KJT232LLC La Quinta California Energy Climate Zone Total Cond. Floor Area Addition # of Units CA Climate Zone 95 INSULATION 5, 725 n/a Construction Type Area a Roof Wood Framed Attic Cavit ft ( Special Features Status Wall Wood Framed R 38 5,725 Add=R-19.0 New Slab Unheated Slab -on -Grade R 21 4,956 Add=R-5.0 — — — New Demising Wood Framed - no insulation 4,941 Perim = 353' New Door Opaque Door - no insulation 2,330 New - no insulation 20 New r;FENTRATION tion Area{ft) Total Area. U-Fac SHGC 1,319 nta 00.42 Averactor. 180.8 Overhan Sidefins Exterior ShadesNew/Altered Status 713.0 0,4200.25 none none BugScreen New _ Front W) 23 ( 7.7 0.420 0.420 0.25 none none Bug Screen New Right (S) 187.8 0.420 0.25 none none Bug Screen New 0.25 none none Bug Screen New HVAC SYSTEMS -- - -- - - -- - -- -__ Q'It . Heatin Min. Eff Coolin Min. Eff 7 Split Heat Pump 7.70 HSPF Split Heat Pump 16.0 Thermostat Status 1 Split Heat Pump 7.70 HSPF SEER Split Heat Pump Setback New __ 1 Split Heat Pump 7.70 HSPF 16.0 SEER Split Heat Pump 16.0 Setback New _ HVAC DISTRIBUTION SEER Setback New Location HeatingDuct Cooling Duct Location - HVAC casita Ducted R-Value Status HVAC mstr D Ducted Ducted Attic - — 8.0 New HVAC rt D g Ducted Ducted Attic — _ - - — 80 ._ New WATER HEATING _ D Ducted Attic — 8 0 _ New Qty. Type Gallons Min. Eff Distribution _ ? Small Instantaneous Gas 0 StatuS — — — — 0.95 Standard — — - — New 16of49 RESIDENTIAL MEASURES SUMMARY Project Name Residence Building Type ❑ Single Family p Addition Alone RMS-1 Date Project Address — ❑ Multi Family ❑ Existing+ Addition/Alteration 121191201 The Hideaway KJT232LLC La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area Addition # of Units INSULATION 5, 725 n�a 1 Construction Type Area Cavity tf,2 Special Features Status FENESTRATION Orientation Area HVAC SYSTEMS Qt Heatin 1 Split Heat Pump 1 Split Heat Pump HVAC DISTRIBUTION Location Heati HVAC bed _ Ducted HVAC 2nd Ducted WATER HEATING Qty. Tvae 7.2 Total Area: -4191 Glazing Percents e; 23.0% 1 New/Altered Aver a a U-Factor: 0.42 U-Fac SHGC Overhan Sidefins Exterior Shades Status Min. Eff Cooling Min. Eff Thermostat Status 7.70 HSPF Split Heat Pump 16 0 SEER Setback New 7.70 HSPF Split Heat Pump 16.0 SEER Setback New Duct W Cooling Duct Location R-Value Status Ducted Attic 8.0 New Ducted Attic _ 8.0 New Gallons Min. Eff Distribution Status ID: Paoe 17 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review flee respective section for more informalion. 'Exceptions may apply, Revised 04/2017 Building Envelope Measures: § 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfmlft2 or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011: § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use Wactors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.E-13 forcom fiance and must be caulked andlarwe3therstri ed.' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, aSketed, or weather slipped. § 110.7: Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing § 110.8(i): material must meet the r uirements of 110:. i when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or'less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit Infiltration and exfiltration as specified in § 110.7, including but not limited to lacin insulation eitlier above or below the roof deck or on Lop of a d all cell.. ' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factorof 0.102 or less (R-19 in 2x6 or U- § 150.0(c): factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembl ' § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; arid, when installed as art of a heated slab floor, meet the r uir$menls of 110.8 1. Vapor Retarder. In Climate Zones 1.16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This § 150.0(g)1: ulrement also a ties to controlled ventilation crawls a for bu'ildt s Com I 'n with the exception to 1160.0(d). Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class It vapor retarder must be installed on the conditioned space side of all § 150.0(g)2: insulation in all exteriorwalls, vented attics, and unvented attics with air -permeable insulation. 150.0 Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a § (q)' maximum U-factor of 0.58; or the weighted averse U-factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150,0(e)1 B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is 2guir. ed with a re!adtly accessible, operable, and ii ht fitlin dam r ar combustion air control dOce.' § 150.0(e)1 C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated a Alances must be certed the manufacturer to the Energy Commission: § 110,2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2 A through TABLE 110.2 K: Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for con ression heating is h1 her than the.cut off ten erature for su lementa heat: ' § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3 C 5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTUlhr (2 kW) must have isolation valves with hose bibbs or other fiiiin s on both cold water and hot water lines of water heatin systems to allow for water tank flushi when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without.an electrical su t volts a connection with Iloi li hts that consume less than 150 Btu/hr are exem t ;and a4 and S heaters. Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions s ecified in § 150.0 h 2. 2016 Low -Rise Residential MandatorI Measures Summa § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any d er vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturers Instructions. § 150.0(j)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must ll be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures' Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof § 150.0(j)2B: and non -crushable casIN or sleeve' Water piping and cooling system line Insulation. Pipe for cooling system lines must be insulated as specified in § 150.0(j)2A. Distribution § 150.O0)2C: i in for steam and h dronic heailn2 systems or hot waters stems must meet the requirements in TABLE 120.3-A' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be Installed with a cover suitable for outdoor service. For example, protected by § 150.06)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the materiai. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II va v retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural drainin without um assistance; and a as su i line with a capacity of at least 200,000 f3tufhr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(tl)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certif to the customer, in writing, that the insulation meets this requirement. CHIC Compiiance. All air-distribufion system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC. §§ 601.0, 602A 6030, 604.0. 605.0 and ANSIISMACNA-006.2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return•air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3,1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/. inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or ccnstrucled with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying condilioned air. Building cavities and support plalforms may contain ducts. Ducts installed in cavities and su ort atforms must not be compressed to cause reductions in the cross -sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such toe is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field4abricated duct systems must comply with applicable requirements for: pressure sensitive tapes, mastics, sealants, and other re uiremenis s ❑tiled for duct construction. § 150.0(m)7, Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dam rs. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manuall . rated dampers in all o enin s to the outside, exoe t comhusiiorR inlet and outlet air a eni s and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with q 150.0 m 11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure dfoo, and labelln9 requirements of 150.D m 12. - 2016 Low -Rise Residential Mandato Measures Summa Duct System Sizing and Air Filter Gd1le Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The space conditioning system must also demonstrate airflow ? 350 CFM per ton of nominal cooling capacity through the return § 150 0(m)13: grilles, and an air -handling unit fan efficacy <_ 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central foB92 stems' Vfor Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard U.Z. Neither window operation no §150.0(0): cperation of central forced air system air hanl fitegrated ventilation systems are permissible methods of ole iiuildin ventilation.Fcation and Diagnostic Testing. Whole-builtiltion airflow must be confirmed through field verification and diagnostic § 150.0(o)lA: tcordance with Reference Residential A end'ix RA3.7. Pool and Spa Systems and Equipment Measures: Certlficabon try Manufacturers. Any pool or spa heating system of equipment must be certified to have ail of the following: a thermal effir;ieiicy § 110.4(a): that complies wills the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heatin F10A 1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filler and the heater, or dedicate suction and return lines, or built-in or built-up connections to allow for future sotar heatin . 2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. §.)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that w141 allow all um s to be set or ra rammed to run onlydurtn off-peak electric demand rieds. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. _ 150.0 Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow § (p) ratp nininn. filters. and valves' Lighting Measures: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements § 110.9: of 110.9.' JAB High Efficacy Light Sources. To qualify as a JAB high efficacy light source for compliance with § 150.0(k), a residential light source must § 110.9(e): be certified to the Enem Commission acomording to Reference Joint Appendix JAB. § I50.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)l B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. 7-1 Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1 C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)l C. A JA8-2016-E light source rated for elevated tem erature must be installed b final InsMotion in all recessed downfi ht luminaires in ceilin . Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output Frequency no less than § 150.0(k)l D: 20 kHz. ht lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no Night Lights. Permanently installed nig or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled § 150.0(k)1 E: more than 5 watts of power per luminaire b vacant r sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods must meet the a iicabte fe uirements of 150. k Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)l G: with Reference Joint Appendix JAB. Installed lamps must be marked with "JA8-2016" or"JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)l H. Enclosed Luminaires. Light sources installed in enclosed luminaires must be JAB compliant and must be marked with "JA8-2016-E.' § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with - 150.0 k . § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (FMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 f ; and meets all other requirements in § 150.0 k 2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 ;and all other r ulrements in 150.0 k 2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the funclionaiity of a dimmer accordin to 110.9 and com lies with all other a licabie r uiremenls in 150.t7 k 2. 2016 Low -Rise Residential Mandatory Measures Summa § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, exce l luminaires:in closets less than 70 §quare feet and luminaires in hallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0 k 3A or with the app4cable requirementsin §§ 110.9 130.0 130.2 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0(k)39 or§ 150.0 k 3D mustcomply with the applicatAe requirements in §§ 110.9, 130.0,130.2,130.4 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the a stable re uirements in 110.9,130.0, i30.2,130.4 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of over ascleterrinined according to § 130.0 c . § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the a licable r uirements for nonresidential airages in §§ 110.9 130.0.130.1 130.4, 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9,130.0,130.1,140.6 and 141.0; and K. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be ca able of turning the light fully on and off from all designed paths of Ingress and Less. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.10 b throe h § 110.10. e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feel each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane! § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathAay for routing of plumbing from the solar zone to the water -healing s stem. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 11 0.10c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric" HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Residence Dare Systein Name 12/19/2018 HVAC casita EFloor Area Sulstuhis G CHE7;70 SYSTEM LOAD 503 Systems 1 m COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible Outor S stem0 Total Room Loads 331 6,932 t Stuh0 157 186 7,30, Return Vented Lighting p his ft6 Return Air Ducts 327 Cooling, System 221 Return Fan p p Output per System 35,400 Ventilation 0 p 0 0 0 Total Out ut Htuh 35,400 Supply Fan 89 $� Total Out ut Tons 3.0 Supply Air Ducts 327 221 Total Output Btuhls ft 70.4 Total Out ut s ftlTon 170.5 TOTAL SYSTEM LOAD Air S stem 7,675 157 7,655 CFM erS stem 1,200 HVAC EQUIPMENT SELECTION All cfm 1,200 Carrier 3 Ton Split HP Airflow cfmis ft 2.39 24,537 5,215 22,172 Airflow CfmlTon 406.8 Cl Air j°Io 0.0°/n Total Adjusted System Output 24,537 5,215 Outside Air cfmis ft 0.00 (Adjusted for Peak Design condifionsy 22,172 Note: values above iven at ARI conditions TIME OF SYSTEM PEAK HEATING SYSTEM PSYCHROMETRICAirstream Tem eratures at Time of Heatin peak Aug 3 PM Jan 1 AM 26 OF 68 OF 105 OF 105 °F Outside Air @ U I 0 cfm Heating Coil Supply Fan + 1,200 cfm 105 °F 68 "F ROOM I � f 68 OF COOLING SYSTEM PSYChfROMETRICS Airstream en'llperatures at Time of Cooling Beak 112 / 73 OF 75/62 OF 55 / 54 OF � If - Outside / 54 r Outside Air 0 cfTO m Supply Fan Cooling Coil 1,200 cfm 55 / 54 OF 46.2% ROO 75 / 61 OF 75 / 61 OF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Residence 12/19/2018 System Name Floor Area HVAC mstr 1,200 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 685 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Sensible Heating System Sensible Latent CFM Output per System 35,500 35,500 14,151 375i 280 10,978 Total Output Btuh 0 Output Btuh/s ft 29.6 667 332 Cooling System 0 0 Output per System 35,400 0 0 0 0 Total Output Btuh 35,400 S9 667 15,574 375 -a9 Total Out ut Tons 3•0 332 Total Output Btuh/s ft 29.5 Total Output s ft/Ton 406.8 11,553 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 3 Ton Split HP 24,668 5,157 22,172 Airflow (cfm/s ft) 1 00 22,172 Airflow cfm/Ton) 4068 0•0% Outside Air (%) Total Adjusted System Output (Adjusted for Peak Design conditions) 24,668 5,157 Outside Air (cfm/sqft) 0.00 Aug 3 PM Note: values above given at ARI conditions TIME OF SYSTEM PEAK Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 IF 68 OF 105 IF 105 OF op b a Z "H Outside Air -4 k-- 0 cfm Heating Coil Supply Fan 1,200 cfm 105 OF ROOM 68 "F 68 IF 1 COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak) 112 173 °F 76 / 62 °F 55 / 54 OF 55 ! 54 OF Outside Air 0 cfm Cooling Coil Supply Fan 56 ! 54 OF 1,200 cfm 46.4% ROOM 76 / 62 °F 75 1 61 IF: HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Residence System Name HVAC grt ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 ❑u ut er system 35,500 Total Room Loads Total Output Btuh 35,500 Return Vented Lighting Out ut Btuhls ft 14.6 Return Air Ducts Coolie 5 tern Return Fan output per System 35.400 Ventilation Total Output Stuh 35,400 Supply Fan Total Output Tons 3.0 Supply Air Ducts Total output Btuhfs ft 14.5 ".I 825A TOTAL SYSTEM LOAD Dale 12/19/2018 Floor Area 2,435 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 1,737 34,494 761 697 27,005 0 1,625 817 0 0 0 0 0 0 0 — - gg 1,625 37,834 761 -89 817 28,551 Total Out ut s on - Air !C�F mer5 tern 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 3 Ton Split HP 25,158 4,821 22.172 Airflow (cfm1s ft 0.49 Airflow cfm1Ton 406.8 ___ _ _ _ — _: Outside Air(°It 0.0% Total Adjusted System Output 25,158 4,821 22,172 Outside Air cft 0.00 (Adjusted for Peak Design conditions) Aug 3 PM Jan 1 AM Note: values above given at ARI conditions TIME OF SYSTEM PEAK HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heatin Peak 2.6 IF 67 OF 105 OF 105 OF f l Outside Air Supply Fan 104 OF 0 cfm Heating Coil 1,200 cfm _ ROOM 68 OF 1 I I COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Coolie Peaks 112 173 OF 76 162 °F 551 54 °F 551 54 OF Outside Air Supply Fan 561 54 OF 0 cfm Cooling Coil 1,200 cfm 46.7% ROOM a 75 162 OF 76 ! 62 OF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Residence System Name HVAC bed ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Out ut er System 35,500 Total Room Load Total Output Btuh 35,5.00 Return Vented Lighting Out ut l3tuh1s ft 44.2 Return Air Duct Coolin System Return Fa Output per System 35,400 Ventilation Total output Stuh 35,400 Supply Fa Total Out ut Tons 3.0 Supply Air Duct Total Output (Btuh1s ft 44.1 T t l O t t H1Tan 272.2 TOTAL SYSTEM LOA Date 12/19/2018 Floor Area 803 COIL COOLING PEAK S s n n n s D COIL HTG. PEAK CFM Sensible Latent CFM Sensible 388 8,116 251 207 8,122 0 382 246 0 0 0 0 0 o 0 89 382 ,970 251 -89 246 8,525 oa u u s Air System CFM er 5 tam 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 3 Ton Split HP Airflow c#mfs ft 1.49 Airflow cfm/Ton 406.8 Outside Air % 0.0% Total Adjusted System Output Outside Air c#mis ft 0.00 (Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heat 26 OF 68 °F 105 OF 105 OF o Outside Air 0 cfm Heating Coil Supply Fan 1,200 cfm 68 OF 1 � I COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cool 112 1 73 OF 75 162 OF 55 / 54 OF 551 54 OF -ti: • Outside Air IN J— U. Supply Fan 0 cfm Cooling Coil 1,200 cfm 75 162 OF 5,2521 1 22,172 24,526 5,252 L 22,172 Aug 3 PM Jan 1 AM F--� 105 OF ROO M - 68 OF 55154 "F= 46.3% ROOM HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Residence Date 12/19/2018 Floor Area 784 System Name HVAC 2nd ENGINEERING CHECKS SYSTEM LOAD Number of S stems 1 COIL CFM Total Room Loads 567 Return Vented Lighting Return Air Ducts Return Fan Ventilation [ 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. Sensible Latent CFM 11,772 245 235 0 555 0 0 0 0 89 555 12,971 245 PEAK Heating System Sensible_ Output per System 35,500 9,220 Total Output Btuh 35,500 Output Btuh/s ft 45.3 279 Cooling System 0 Output per System 35,400 0 Total Output (Btuh 35,400 -89 Total Output Tons 3.0 279 Total Output Btuh/s ft 45.2 Total Output s ft/Ton 265.8 F 9,688 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 3 Ton Split HP 24,640 5,155 22,172 Airflow cfm/s ft 1.53 Airflow cfm/Ton 406.8 Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 24,640 5,155 22,172 Aug 3 PM Jan 1 AM Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak. 26 OF Outside Air Ar 0 cfm 68 OF 105 OF 105 OF ° U I 0 ♦ Heating Coil Supply Fan 1,200 cfm I 1 ROOM > 68 COOLING SYSTEM PSYCHROMETRICS JAirstrearn Temperatures at Time of Cooling Peak 112 / 73 °F= Outside Air 0 cfm 75 / 62 OF 75 162 °F= 55 / 54 °F 55 / 54 OF Cooling Coil Supply Fan 1,200 cfm 56 ! 54 "F 46 3% ROOM V" r _ ZONE LOAD SUMMARY Project Name Date Residence 1211912018 System Name Floor Area HVAC casita 503 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM I Sensible Latent CFM I Sensible casita 1.0 0 Aug 3 PM 3311 6,932 157 1861 7,302 TOTALS 0 0 0 01 Aug 3 PM 6,9321 157 7,302 (BLOCK LOAD) ZONE LOAD SUMMARY Residence HVAC mstr ZONE LOAD UMMMARY master 1.0 ro t'Peak Hr CFM Sensible 3 PM 6851 14,151 Aug 3PM + 14,151 375 Cate 1211912018 Floor Area 1,200 3751 280 10,978 10,976 ZONE LOAD SUMMARY Project Name Residence System Name HVAC grt ZONE LOAD SUMMARY Great room Dining 1.0 TOT OA Date 1211912018 Floor Area 2, 435 0 Aug 3 PM 1, 737 34, 494 761 697 ` 27, 005 0 0 01 0 Aug 3 PM 34,494 76> 27,005 {BLOCK LOAa1 ZONE LOAD SUMMARY Project Name Residence System Name HVAC bed ZONE LOAD SUMMARY NAM bedroom 1.0 OA 0 Aug 3 PM 1 388 8,116 01 01 0 0 Aug 3PM 8,116 251 1211912018 Area 803 2511 207 8,122 8,122 ZONE LOAD SUMMARY Project Name Residence System !Name HVAC 2nd ZONE LOAD SUMMARY 1211912018 r Area 784 wIYC IYXIVIC SE4E YSTEM NAME LULILING PEAK HEATING PEAK second Mult. CFM Sensible Latent Heatin OA CFM Peak Hr CFM Sensible Latent CFM Sensible 1.0 0 Aug 3 PM 567 11,772 245 235 9,220 TOT. 0 0 0 0 Aug 3 PM 11,772 2451 9,220 j ROOM LOAD SUMMARY Project Name Residence System Name HVAC casita ROOM LOAD SUMMARY 1211912018 Floor Area 503 Zone Name Room Name Mult. ROOM COOLING PEAK CFM Sensible Latent COIL COOLING PEAK CFM I Sensible Latent COIL HTG. PEAK CFM Sensible casita Casita Guest Quarters 1 331 6,932 157 331 6,932 157 186 7,302 PAGE TOTAL I 331 6,932 TOTAL " II 3311 6,932 Total irtchides ventilalion load for zonal 7,302 7,302 ROOM LOAD SUMMARY Project Name Date Residence 1211912018 System Name Floor Area HVAC grt 2,435 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible Latent CFM Sensible Latent CFM Sensible Great room Dining Great Room Dining Living 1 1 1,7371 34,494 761 1,737 34,494 761 697 27,005 PAGE TOTAL TOTAL" " Total includes ventilation load for zonal 1,737 34,494 761 697 27,0055 1,737 34,494 J 761 697 27,005 ROOM LOAD SUMMARY Project Name Date Residence 12/19/2018 System Name Floor Area HVAC bed 803 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible bedroom Bedrooms 2 & 3 1 388 8,116 251 388 8,116 251 207 8,122 PAGE TOTAL 388 8,116 251 267 8,122 TOTAL ' 388 8,116 Z 1 2 17 8,122 " Total includes ventilation load For zonal s stervis. ROOM HEATING PEAK LOADS Project Name Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Guest Quarters Time of Peak Floor Area 503.00 ftZ Outdoor Dry Bulb Temperature 68 OF Indoor Dry Bulb Tem erature Conduction R-38 Attic R-21 Wall Residential Window.42.25 Slab -On -Grade Area U-Value 0.0169 X 0.0513 X 0.4200 X 0.7300 X X X X X X x X x X x X x X x x x x x x x x x x x x x x x x x x x x 1 x� Items shown with an asterisk (') denote conduction through an interior surface to another room AT OF Date 1211912018 ■ 1 1 1 I Jan 1 AM 26 OF Btu/hr 358 1,495 1,976 2,300 6,129 503 9.00 X 0.348 / 60 J X 42 = 1,174 Infiltration:[ 1.00 X 1.064 X X AT Schedule Air Sonsitile Area Celltng Height ACH Fraction -- 7.302 TOTAL HOURLY HEAT LOSS FOR ROOM ROOM HEATING PEAK LOADS Project Name Residence DESIGN CONDITIONS ROOM INFORMATION Master Bedroom Time of Peak Room Name 1,200.00 ftZ Outdoor Dry Bulb Temperature Floor Area 68 OF Indoor Dry Bulb Temper Conduction R-38 Attic R-21 Wall Residential Window.42.25 Slab -On -Grade Area U-Value 0.0169 X 0.0513 X 0.4200 X 0.7300 X X X X X X X X X X X X X X X y X X X X X X X X X X X X X X X X Items shown with an asterisk (") denote conduction through an interior surface to another room AT OF Date 1211912018 Page Total Jan 1 AM 26 OF Btu/hr 854 1,517 3,722 2,085 8,178 1.00 X 1,200 X 9.00 0.348 X / 60 J X AT 42 = 2,800 Infiltration:[ X 1.064 Schedule Air Sensible Area Ceiling Height ACii Fraction 10.978 TOTAL HOURLY HEAT LOSS FOR ROOM ROOM HEATING PEAK LOADS Project Name Residence DESIGN CONDITIONS ROOM INFORMATION Room Name Great Room Dining Living Time of Peak 2,435.00 ftz Outdoor Dry Bulb Temperature Floor Area 68 °F Indoor Dry Bulb Temperature Conduction R-38 Attic R-21 Wall Residential Window.42.25 Wood Door Slab -On -Grade Area U-Value 0.0169 x 0.0513 x 0.4200 x 0.5000 x 0.7300 x X X X X X X X X x x x x x x x x x x x x x x x x x x x x Items shown with an asterisk (') denote conduction through an interior surface to another room AT OF 1)atu, 1211912018 Page Total Jan 1 AM 26 OF Btulhl 1,733 2,878 11,538 422 4,752 21,324 7 q2 _ 5,681 1:064 2, 435 x 9.00 x 0.348 i 60 J X Infiltration:[ 1.00 x X Area Ceilingiieigt�l RCH AT Schedule Rlr Sensible Fraction 27,005 TOTAL HOURLY HEAT LOSS FOR ROOM ROOM HEATING PEAK LOADS Project Name Residence ROOM INFORMATION DESIGN CONDITIONS Bedrooms 2 & 3 Time of Peak Room Name 803.00 ftz Outdoor Dry Bulb Temperature Floor Area 68 OF Indoor Dry Bulb Tem erature Conduction R-38 Attic R-21 Wall Residential Window.42.25 Slab -On -Grade Area U-Value 0.0169 x 0.0513 x 0.4200 x 0.7300 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Items shown with an asterisk (') denote conduction through an interior surface to another room AT OF Date 12/19/2018 1 1 1 1 1 1 Jan 1 AM 26 OF Btulhr 572 1,222 2,769 1,686 6,249 1.00 1.064 x 803 x 9.00 x 0.348 / 60 ] X 42 1,873 Infiltration:[ x b Area Ceiling Height ACH AT Schedule Air Sensible Fraction 8,122 TOTAL HOURLY HEAT LOSS FOR ROOM ROOM HEATING PEAK LOADS Project Name Residence ROOM INFORMATION Room Name Floor Area Indoor Dry Bulb Temperature Conduction R-38 Attic R-21 Wall Residential Window.42.25 DESIGN CONDITIONS 2nd Floor Time of Peak 784.00 ft2 Outdoor Dry Bulb Temperature 68 OF Area U-Value 0.0169 X 0.0513 X 0.4200 X X X X X X X X X X X X x x x x x x x x x x x x x x x x x x x Items shown with an asterisk (') denote conduction through an interior surface to another room Infiltration:[ 1.00 x sctiadule Fraction AT OF Qalc 1211912018 Page Total Jan 1 AM 26 OF Btulhr 558 3,566 3,267 7,391 1.064 X 784 x 9.00 x 0.348 160 X 42 = 1,829 Air Sensible Area Ceiling Ho�gfzt ACH AT 9.220 TOTAL HOURLY HEAT L OS5 FOR RODM RESIDENTIAL ROOM COOLING LOAD SUIVIMARY-771�� Date Project Name 12/19/2018 Residence ROOM INFORMATION DESIGN CONDITIONS 112 OF Room Name Casita Guest Quarters Outdoor Dry Bulb Temperature 73 OF 503.00 ft2 Outdoor Wet Bulb Temperature 34 OF Floor Area o indoor Dry Bulb Temperature 75 F Outdoor Dail Ran e: opaque Surfaces R-38 Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall Orientation Area U-Factor CLTD' 503.0 X 0.0169 X 56.0 = 240.0 X 0.0513 X 24.3 = 180.0 X 0.0513 X 32.6 = 82 0 X 0.0513 X 27.1 = 192.0 X 0.0513 X 32.4 = X X = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature DMcrence (CU D) Shaded Unshaded Orientation Area GLF Area GLF Fenestration 17.7 + 24.0 XMUMO.ox 19.5 = X 17.7 + 16.0 X 32.0 XX 17.7 + 24.0 X 31.0 17.7 + 24.0 X 31.0 X 17.7 + 24.0 X 31.0 X = X + X + X = X + X = X + X = Page Total Internal Gain - Occupants X 245} Btuh/occ cu = Ocants E50 _ - - I1 - E u's meni Floor Area X 0.50 w/sgft 1.064 X 1.20 X 20.75 X 37 = Infiltration: ELA AT Air Sensible CFM TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain 1551 Btuh/occ. pccupants 1.5 � Occupants X 4,771 X 1.20 X � _ 20.75 X-0.00065 = Infiltration: Air Latent CFM Ei A nW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM Btulhr 114 319 1,511 Btulhr 467 512 744 744 744 3,21 Btulhr Btulhr -77 RESIDENTIAL ROOM COOLING LOAD SUMMARY )-,,iC Project Name 1211912018 Residence =ft'Outdoor CONDITIONS 112 °F ROOM INFORMATION Masry Bulb Temperature 73 OF Room Name et Bulb Temperature 34 °F Floor Area Dail Ran e: Indoor Dry Bulb Temperature O a ue Surfaces R-38 Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall orientation Area U-Factor CLTD' Btulhr 0.0169 X 56. 1 = X 0.0513 X 24.3 = 0.0513 X 32.6=X 0.0513 X 27.1 =X0.0513 01,2000X X X 32.4 = E2, X X = X X = X X = X X _ Page Total Items shown with an asterisk (") denote conduction through an interior surface to another room- 1 . Cooling Load Temperature Difference (CLI-D) Shaded Unshaded Fenestration E 7 Orientation Area 0.0 XX GLF 17.7 ++Area 51.0 XX GLF32.0 2.0 = 0.0 X 17.7 + 160.0 X 32.0 = X + X X + X X + X X + X X + X = X + X Page Total Internal Gain 245 Btuh/occ. _ Occu ants 3.6 Occupants X — 1= ui meni 1,200 Floor Area X 0.50 w/sgft 1.064 X 1.20 X ELA 9.49 X Infiltration: A 3� _ Air Sensible CFM TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain 155 Btuh/occ. _ 3.6 Occupants X ❑ccupants 4 771 X 1 20 X 49.49 X-0.00065 = Infiltration: ELA oW Air Latent CFM TOTAL HOURLY LATENT HEAT GAIN FOR ROOM — — -- — — Btulhr 1,63 5,11 6,745 Btulhr 883 2, 048 q34 14,151 Btu/hr 559 -183 RESIDENTIAL ROOM COOLING LOAD SUMMARY Date Proiect Name 1211912018 Residence ROOM INFORMATION DESIGN CONDITIONS 112 OF Room Name Great Room Dining Living Outdoor Dry Bulb Temperature 73 OF Floor Area 2,435.00 V Outdoor Wet Bulb Temperature 34 OF 75 OF Indoor Dry Bulb Tem erature Outdoor Dail Ran e: Opaque Surfaces R-38 Attic R-21 Wall R-21 Wall R-21 Wall R-21 Wall Wood Door Orientation Area U-Factor CLTD' Btulhr 2,435.0 XM.0169 X 56.0 = 340.0 X .0513 X 24.3 = 430.0.0513 X X 32.6 = 289.1 X .0513 X 27.1 = 276.7 X.0513 X 32.4 = 04,641 XXX .5000 X 32.4 =20.1 = X X X X - Page Total asterisk (') denote conduction through an interior surface to another room Items shown with an 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Orientation Area GLF Area - GLF Btulhr 779 Fenestration X 17.7 + 40.0 X 19.5 = (N) F 17.7 X + 240.0 X 32.0 = 7,673 8 (E) 17.7 X + 40.0 X 32.0 = 1,279 G (E) 17.7 X goo + 160.0 X 32.0 = 5,115 - 10 (E) X 17.7 48.0 +9(S) X 19.0 = 912 X 17.7 + 6.3 X 19.0 = 120 H (S) X 17.7 + 6.3 X 19.0 -_ 120 i (s) 17.7 0.0 X + 6.3 X 19.0 - 120 K (S) 0.0 X 17.7 + 24.0 X 19.0 -_ 45f (S) Page Total 16, 57, Btulhr Internal Gain 7.3 Occupants X i - - 2451 Btuh/occ. - 1,M 4,15 occupants `N/sgft = 2,435 Floor Area X L E ui ment 1.064 X 1.20 X 0.43 X 37 � 4, 75 Infiltration: ELA AT CFM Par Sensible TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM - - Btu/hr Latent Gain � 155 gtuhlocc. _ Occupants 7.3 Occupants X 4,771 X 1.20 X 100.43 X-0.00065 = Infiltration: ELA ❑rV Air Latent CFM 1,1 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Residence ROOM INFORMATION DESIGN CONDITION Room Name Floor Area Indoor Dry Bulb ue Surfaces S Great Room Dining Living Outdoor Dry Bulb Temperature 2,435.00 ftz Outdoor Wet Bulb Temperature 75 OF Outdoor Dai1v Ranrie: Orientation 1211912018 Area U-Factor CLTD' X X = X X = X X99 = X X = X X = X X = X X = X X = X X = Pa a Total Items shown wilh an asterisk (') denote conduction through an interior surface to another room g 1. Cooling Load Temperature Difference (CLTD) Fenestration 1 Internal Gain Orientation W Shaded Unshaded Area GLF Area GLF 0.0 X 17.7 + 83.2 X 31.0 = X + X _ X + X _ X + X _ X + X = X + X = X + X = X + X _ X + X = Page Total 112 OF 73 OF 34 OF Btu/hr Btulhr 2, 580 2, Btu/hr 7-3 245 Btuh/occ. = 1, 712. 2,435 Floor Area X Occupants X F _ 0.50� N,/sgft = 4,155 Infiltration: 1.064 X 1.20 X 100.43 X � v" 1 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 34,4 Latent Gain _ Btu/hr Occupants 7•3 Occupants X 155 Btuh/occ. Infiltration: 4,771 X X 100.43 X-0.000651 _ 3 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,1