BRES2018-041978-495 CALLE TAMPICO a. VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Permit Type/Subtype: BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED Owner:
Application Number: BRES2018-0419 BOB & ROBIN THOMAS
Property Address: 54260 AVENIDA RAM IREZ 54305 AVENIDA VALLEJO
APN: 774244040 LA QUINTA, CA 92253
Application Description: THOMAS / 2,012 SF DWELLING - [VB/RES-3/CLASS A-FR/13D]
Property Zoning:
Application Valuation: $133,621.20
Applicant: Contractor:
BOB THOMAS MAR O / 2019 JOE W STEMMERJR
54305 AVENIDA VALLEJO F 0 42215 WASHINGTON ST #355
LA QUINTA, CA 92253 CITY OF LA QUINTA PALM DESERT, CA 92211
DESIGN & DEVELOPMENT DEPARTMENT (760)880-3525
Llc. No.: 605857
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 70001 of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Cl ss: B License No.: 605857
Date; Contractor:
OWNER -BUILD EC[ARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
() I am exempt under Sec. B.&P.C. for this reason
Date,
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's Address:
Date: 3/7/2019
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier. XEMPT Policy Number:
certify that in the performance of the work for which this permit Is issued, I
shall n t employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700} f the Lahgr�gde, I shall forthwith
comply with those provisions. !! rrjj �
'7
Date: Applicant: ti
WARNING: FAILURE TO SECURE WORKE ' OMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
Following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relati o building
construction, and hereby authorize representatives of this c y t enter he
above mention d property for inspection purposes.
Date: Signature (Applicant or Agent
Date: 3/7/2019
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
Applicant:
BOB THOMAS
54305 AVENIDA VALLEJO
LA QUINTA, CA 92253
BRES2018-0419
54260 AVENIDA RAMIREZ
774244040
THOMAS / 2,012 SF DWELLING - [VB/RES-3/CLASS A-FR/13D]
$133,621.20
Owner:
BOB & ROBIN THOMAS
54305 AVENIDA VALLEJO
LA QUINTA, CA 92253
Contractor:
JOE W STEMMER JR
42215 WASHINGTON ST#355
PALM DESERT, CA 92211
(760)880-3525
Llc. No.: 605857
Detail: 2,012 SF DWELLING - SANTA CARMELITA VALE LA-QUINTA UNIT 26, LOT 24[VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA,
BLOCK WALLS OR DRIVEWAY APPROACH [GLS ARCHITECTURE]. 2016 CALIFORNIA BUILDING CODES.
DESCRIPTION ACCOUNT QTY AMOUNT
BSAS SB1473 FEE 101-0000-20306 0 $6.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $6.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
Credit Card Fee
101-0000-43505
0
$13.50
Total Paid for Credit Card Fee: $13.50
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - CIVIC CENTER
252-0000-43200
0
$942.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - COMMUNITY CENTERS
254-0000-43200
0
$129.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - FIRE PROTECTION
257-0000-43200
0
$433.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF- LIBRARIES
253-0000-43200
0
$344.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - PARK MAINTENANCE
256-0000-43200
0
$40.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - PARKS/REC
251-0000-43200
0
$2,048.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - STREET MAINTENANCE
255-0000-43200
0
$116.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - TRANSPORTATION
250-0000-43200
0
$2,842.00
Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF
101-0000-42403
0
$27.22
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, EA ADDITION 1,00051', PC
101-0000-42600
0
$11.20
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$160.10
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$52.83
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $251.35
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF
101-0000-42408
0
$40.02
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT>7KSF PC
101-0000-42600
0
$200.12
Total Paid for GRADING: $240.14
DESCRIPTION
ACCOUNT QTY
AMOUNT
MULTI -SPECIES RESIDENTIAL 0-8 UNITS - 2018 UPDATE
101-0000-20310 0
$1,290.00
Total Paid for MULTI -SPECIES RESIDENTIAL: $1,290.00
DESCRIPTION ACCOUNT CITY AMOUNT
NEW CONSTRUCTION PERMIT 101-0000-42400 0 $582.69
Total Paid for NEW CONSTRUCTION PERMIT: $582.69
DESCRIPTION
ACCOUNT
CITY
AMOUNT
NEW CONSTRUCTION PLAN CHECK
101-0000-42600
0
$1,164.24
Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,164.24
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PLAN CHECK DEPOSIT- RESIDENTIAL
101-0000-42600
1
$750.00
Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $750.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BACKFLOW DEVICE
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BACKFLOW DEVICE PC
101-0000-42600
0
$5.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BUILDING SEWER
101-0000-42401
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BUILDING SEWER PC
101-0000-42600
0
$18.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$160.08
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$160.08
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 5+ OUTLETS
101-0000-42401
0
$40.02
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 5+ OUTLETS PC
101-0000-42600
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ROOF DRAIN
101-0000-42401
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ROOF DRAIN PC
101-0000-42600
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER HEATER/VENT
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER HEATER/VENT PC
101-0000-42600
0
$8.00
Total Paid for PLUMBING FEES: $525.60
DESCRIPTION
ACCOUNT CITY
AMOUNT
RECORDS MANAGEMENT FEE - MAJOR
101-0000-42416 0
$21.00
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$17.37
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $17.37
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE , 502-0000-43611 1 0 1 $5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
101-0000-42600
($750.00)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SINGLE FAMILY DETACHED 2018 UPDATE
224-0000-20320
0
$750.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SINGLE FAMILY DETACHED 2018 UPDATE
224-0000-20320
0
$1,560.00
Total Paid for TUMF - RESIDENTIAL: $1,560.00
f,AJ/9
Qali�fr&
ta
— GEM nf,b, DESERT —
PERMIT#
PLAN LOCATION:
Project Address:
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #:
Applicant Name:
Address: &eAlzliz1t'
City, ST, Zip: JVZhz
,
Telephone' 70 -
i d 06
Email:R, A C�
Valuation of Project S_�& I Q
Contractor Name: W/vP
New SFD Construction:
Address:
Conditioned Space
J5J6 SF
City, St, Zip
Garage
SF
Telephone:
Patio/Porch
_ SF
Email:
Fire Sprinklers
SF
State Lie: City Bus Lie:
Arch/Eng Name:
Construction Type: Occupancy:
Address: 7q— Q q' T /l,+'
Grading:
City, St, Zip
Telephone: `7�� !,40 r4:) +� 2�
Bedrooms: Stories: IT
Units:
}
Email:
State Lie: I q City Bus Lie:
Property Owner's Name: 7161VI� f .
New Commercial / Tenant Improvements:
Address: ULc f
Total .Building SF
City, ST, Zip Z 6 z 2 r 3
Construction Type: Occupancy:
Telephone: — 7 7 - 9alml 9
I;niai1:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
OFFICE USE ONLY
#
Submittal
Req'd
Rec'd
Plan Sets
Structural Calcs
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
CERTIFICATE OF COMPLIANCE
coo
Desert Sands Unified School District
zy
47950 Dune Palms Road
"=R„u°" "':= 2
�nNcira rxa_;r o
Y MRsAIt E[1.5 y
La Quinta, CA 92253
Date: 3/7/2019 Q ►
C,0A%H JN
u ou,rrr,� �~
No.: 19-01257-1 (760)771-8515
v �n�,n y
Owner: Rob & Robin Thomas Email:
Address: 54305 Jurisdiction: La Quinta
City: La Quinta Tract #:
Type: Single Family Residential
Lot # Street No. Street Name Sq. Feet APN Permit No.
54-260 Avenida Ramirez 2012 772-244-040
[.iAR 0 7 2019
Comments: -•
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fess imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $3.79 X 2012 S.F. or $7,625.48 have been paid for the property listed above and that building
permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Check No.: Credit / Debit Card
Fees Paid By: VISA/Rob Thomas Bank Name/Recipient of Certificate Telephone: 760-777-9603Funding: Residential
By Scott L. Bailey
Superintendent
Fee Collected/ Exempted by:
Arianne Catano
r
Certificate Fees Due: $7,625.48
Credit Card Fees Due: $152.51
Original Payment(s) Rec'd: $0.00
New Payment Rec'd: Y7,777.99
Over/ Under: $0.00
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District(`s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
RECORDING REQUESTED BY:
Lawyers Title Company
WHEN RECORDED MAIL TO:
MAIL TAX STATEMENTS TO:
Rob Thomas and Robin Thomas
54305 Avenida Vallejo
La Quinta CA 92253
DOC # 2018-0191122
05/15/2018 04:32 PM Fees: $14.00
Page 1 of 1
Recorded in Official Records
County of Riverside
Peter Aldana
Assessor -County Clerk -Recorder
"'This document was electronically submitted
to the County of Riverside for recording"
Receipted by: ALYCIA #778
THIS SPACE FOR RECORDER'S USE ONLY:
Order No. 618692442 Escrow No. 070811-JS
APN: 774-244-040-6 GRANT DEED TRA: 020-015
THE UNDERSIGNED GRANTOR(S) DECLARE(S)
DOCUMENTARY TRANSFER TAX is $155.10
[X] computed on full value of property conveyed, or
[ ] computed on full value less value of liens or encumbrances remaining at time of sale.
[ ] Unincorporated area [X] City of La Quinta AND
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged,
Dolores De Luna, Trustee of The Family Trust of Dolores De Luna dated March 28, 2017
hereby GRANT(s) to:
Rob Thomas and Robin Thomas , husband and wife as joint tenants.
WIN
the real property in the City of La Quinta, County of Riverside, State of California, described as: AV
Lot 23 and 24 in Block 289 of Unit 26, Santa Carmelita at Vale La Quinta, as shown by map on file in Boob
Page 50 of Maps Records of Riverside County, California.
Dated May 10, 2018
Dolores De Luna, Trustee of The Family Trust of Dolores
De Luna dated March 28, 2017
By d /hP S ri(I ea. r2r 4 S J_
Dolores De Luna, Trustee
A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to
which this certificate is attached, and not the truthfulness, accuracy, or validity of that document.
STATE OF
COUNTY OF 'm
On it before me, A Notary Public personally
appeareA�=who proved to me on the
basis of satisfactory evidence to be the parson(s) whose name(s) islare subscribed to the within instrument and acknowledged
to me that helshelthey executed the same in his/harltheir authorized capacity(ies), and that by histherltheir signatures) on the
instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument.
I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and
correct.
WITNESS nd an official seal.
Signature (Seal) V AMBRIZ
Notary Public - California
i a Riverside County z
' Commission # 2175004
' My Comm. Expires Dec 9. 2020
Mail tax statements to:
ReMm address as shown above
IN
Page 1 of 1 Requested By: tlivingston, Printed: 3/7/2019 10:06 AM
Doc: RV:2018 00191122-06065
Building Permit: Number: _OaE.S2ots —ig(q
Project Description: SFR
Exempt:
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
Plan Submittal Date'
Job Site Address.
Owners Name
Number, Street, or PO Box
City, State, Postal Code
Owner's Phone Number
Owner's E-Mail Address
Project Managers Name
Project Manager's Phone Number
Project Manager's E-mail Address)
2/28/2019
54260 Avenida Ramirez
Brian Stemmer
74478 Hwy 111 #355
Palm Desert, CA. 92260
760-880-3525
;stem me rcai d c.fr. cem
Joe Stemmer Jr.
760-880-3525
j�t�mmer�:: dam. rr, rtem
r YL
I;n n 7 2019
Builder I Contractorl Joe Stemmer Jr.
Number, Street or PO Box1 42215 Washington St. #355 t_
City, State, Postal Code Palm Desert, CA. 92211
Project Square Footage; Approx. 2,012 sq ft
City Approval By Renado Gouldlock-DEC/Burrtec Waste
Date of City Approval L2-8 /
Materials To Be Discarded:
Product
Tons
Trash
8.25 Not recyclable Product
Tons
Asphalt
0.00 Recyclable
Masonry (broken)
0.00 Recyclable
Brick/Block
0.00 Recyclable
Plaster
2.25 Recyclable
Cardboard
0.00 Recyclable
Scrap Metal
0.00 Recyclable
Commingled
0.00 Recyclable
Tile (floor)
0.00 Recyclable
Concrete
9.00 Recyclable
Tile (roof)
0.25 Recyclable
Drywall
1.00 Recyclable
Wood
3.25 Recyclable
Donated /Reuse"
0,00 Recyclable
Landscape Debris
0.00 Recyclable
"Describe Items
_
Totals: Recycle Trash
Projected Diversion:
15.8
1 8.31
165,63°le
I understand it Is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is
diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or
demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still
issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the
DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through
bi-monthly reports- If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer
Owner I Developer 1 Project Manager I Superintendant Date
BUILDING ENERGY ANALYSIS REPORT
p� �, zotg- 0H 19
PROJECT:
THOMAS RESIDENCE
LOT 24 AVENIDA RAMIREZ
LA Q U I NTA, CA 92253
Project Designer:
RUBEN ROMERO
74991 JONI DR #9
PALM DESERT, CA 92260
Report Prepared by:
Armando Chavez
44890 SEELEY
LA Q U I NTA, CA 92253
iVI1V fA 0278.1840
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE BY
Job Number:
2017-GLS-103
Date:
12/18/2018
RECEIVED
FEB 21 2019 c�
INTERWE.ST
CONSULTING GROUP
RECEIVED
FEB 18 REC'D
cmrOFLAA
AlII'111' DrMx*mewr
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
I TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF-1 R-PRF-01-E Certificate of Compliance 3
Form RMS-1 Residential Measures Summary 12
Form MF-1 R Mandatory Measures Summary 13
HVAC System Heating and Cooling Loads Summary 17
I EnergyPro 7.1 by EnergySoft _ Job Number: ID: 2017-GLS-103 User Number: 20648 1
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: THOMAS RESIDENCE Calculation Date/Time: 13:04, Tue, Dec 18, 2018
Calculation Description: Title 24 Analysis
Input File Name: 104 - LOT 24 AVENIDA RAMIREZ.ribd16x
CF1 R-PRF-01
Page 1 of 9
GENERAL INFORMATION
01
Project Name
THOMAS RESIDENCE
02
Calculation Description
Title 24 Analysis
03
Project Location
LOT 24 AVENIDA RAMIREZ
City
LA QUINTA
05
Standards Version
Compliance 2017
L04
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
09
Software Version
CBECC-Res 2016.3.1 (1019)
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
270
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ftZ)
2012
15
Number of Zones
1
16
Slab Area (ft)
2012
17
Number of Stories
1
18
Addition Cond. Floor Area(ft2)
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ftZ)
n/a
21
Glazing Percentage (%)
16.4%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ftZ-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
0.28
2.04
-1.76
-628.6%
Space Cooling
81.31
65.81
15.50
19.1%
IAQ Ventilation
1.15
1.15
0.00
0.0%
Water Heating
6.33
10.32
-3 99
-63.0%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
89.07
79.32
9.75
10.9%
Registration Number: 218-P010332255A-000-000-0000000-0000 Registration Date/Time: 2018-12-18 13:13:02 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-18 13:04:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: THOMAS RESIDENCE Calculation Date/Time: 13:04, Tue, Dec 18, 2018
Calculation Description: Title 24 Analysis Input File Name: 104 - LOT 24 AVENIDA RAMIREZ.ribd16x
CFI R-PRF-01
Page 2 of 9
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency EDR of Proposed Efficiency
EDR Value of Proposed PV + Battery T Final Proposed EDR
53.4 49.3
0.0 49.3
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV)
renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified.
Notes:
• PV generation will be capped @ proposed design electric use no battery)
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cool roof
• Insulation below roof deck
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
--None --
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Number of Dwelling
Number of Ventilation
Number of Water
Project Name
Conditioned Floor Area (ft2)
Units
Number of Bedrooms
Number of Zones
Cooling Systems
Heating Systems
THOMAS RESIDENCE
2012
1
3
1
0
1
Registration Number: 218-P010332255A-000-000-0000000-0000 Registration Date/Time: 2018-12-18 13:13:02 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-18 13:04:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: THOMAS RESIDENCE Calculation Date/Time: 13:04, Tue, Dec 18, 2018
Calculation Description: Title 24 Analysis
Input File Name: 104 - LOT 24 AVENIDA RAMIREZ.ribdl6x
CFI R-PRF-01
Page 3 of 9
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Z1
Conditioned
HVAC-Z11
2012
10
DHW Sys 1
n/a
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door Area (ftZ)
Tilt (deg)
N-518
Z1
R-21 -
0
Left
518
131.007
90
E- 470
Z1
R-21 --
90
Back
470
35.5
90
S - 518
Z1
R-21 --
180
Right
518
77
90
W -240
Z1
R-21-
270
Front
240
79.5036
90
N - 50
Z1
R-21 --
0
Left
50
0
90
E -46
Z1
R-21 --
90
Back
46
0
90
S - 50
! Z1
R-21
180
Right
50
0
90
W- 46
Z1
R-21 --
270
Front
46
0
90
20122
Z1
R-38 + R-13
n/a
n/a
2005
n/a
n/a
OPAQUE SURFACES — Cathedral Ceilings
01
02
03
04
05
06
07
08
09
10
Name
Zone
Type
Orientation
Area (ft)
Skylight Area
(ft2)
Roof Rise
(x in 12)
Roof
Reflectance
Roof
Emittance
Cool Roof
2012
Z1
R-38 + R-131
Left
7.1
7
0.2
0.86
0.88
Yes
ATTIC
01
02
03
04 05
06
07
08
Name
Construction
Type
Roof Rise Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Z1
Attic RoofZ1
Ventilated
0.2 0.86
0.88
No
Yes
Registration Number: 218-P010332255A-000-000-0000000-0000 Registration Date/Time: 2018-12-18 13:13:02 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-18 13:04:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: THOMAS RESIDENCE Calculation Date/Time: 13:04, Tue, Dec 18, 2018
Calculation Description: Title 24 Analysis
Input File Name: 104 - LOT 24 AVENIDA RAMIREZ.ribd16x
CF1 R-PRF-01
Page 4 of 9
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
3056 - 19
Window
N- 518 (Left-0)
3.0
5.5
1
16.5
0.33
0.25
Insect Screen (default)
6080 - 17
Window
N- 518 (Left-0)
6.0
8.0
1
48.0
0.33
0.25
Insect Screen (default)
3056 - 17
Window
N- 518 (Left-0)
3.0
5.5
1
16.5
0.33
0.25
Insect Screen (default)
3013 - 20
Window
N- 518 (Left-0)
3.0
1.3
0.962
3.8
0.33
0.25
Insect Screen (default)
6013 - 18
Window
N- 518 (Left-0)
6.0
1.3
0.962
7.5
0.33
0.25
Insect Screen (default)
3013 - 21
Window
N- 518 (Left-0)
3.0
1.3
0.962
3.8
0.33
0.25
Insect Screen (default)
3650 - 12
Window
N- 518 (Left-0)
-
-
1
17.5
0.33
0.25
Insect Screen (default)
3650 - 11
Window
N- 518 (Left-0)
-
- -
1
17.5
0.33
0.25
Insect Screen (default)
1616 - 10
Window
E- 470 (Back-90)
----
1
2.3
0.33
0.25
Insect Screen (default)
3020 - 9
Window
E- 470 (Back-90)
1
6.0
0.33
0.25
Insect Screen (default)
5050 - 8
Window
E- 470 (Back-90)
----
---
1
25.0
0.33
0.25
Insect Screen (default)
1616 - 7
Window
E- 470 (Back-90)
----
1
2.3
0.33
0.25
Insect Screen (default)
3020 - 6
Window
S - 518 (Right-180)
--
1
6.0
0.33
0.25
Insect Screen (default)
5050 - 5
Window
S - 518 (Right-180)
----
----
1
25.0
0.33
0.25
Insect Screen (default)
3020 - 6 2
Window
S - 518 (Right-180)
--
-
1
6.0
0.33
0.25
Insect Screen (default)
5040 - 3
Window
S - 518 (Right-180)
----
-
1
20.0
0.33
0.25
Insect Screen (default)
5040 - 2
Window
S - 518 (Right-180)
---
-
1
20-0
0.33
0.25
Insect Screen (default)
6080 - 1
Window
W - 240 (Front-270)
6.0
8.0
1
48.0
0.33
0.25
Insect Screen (default)
3080 - 15
Window
W - 240 (Front-270)
3.0
8.0
1
24.0
0.33
0.25
Insect Screen (default)
6013 - 16
Window
W - 240 (Front-270)
6.0
1.3
0.962
7.5
0.33
0.25
Insect Screen (default)
TUB SKLT.
Skylight
2012 (Left-0)
1
1.0
0.48
0.23
TUB SKLT. 2
Skylight
2012 (Left-0)
1
1.0
0.48
0.23
TUB SKLT. 3
Skylight
2012 (Left-0)
1
1.0
0.48
0.23
TUB SKLT. 4
Skylight
2012 (Left-0)
1
1.0
0.48
0.23
TUB SKLT. 5
Skylight
2012 (Left-0)
1
1.0
0.48
0.23
TUB SKLT. 6
Skylight
2012 (Left-0)
1
1.0
0.48
0.23
TUB SKLT. 7
Skylight
2012 (Left-0)
1
1.0
0.48
0.23
Registration Number: 218-P010332255A-000-000-0000000-0000 Registration Date/Time: 2018-12-18 13:13:02 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-18 13:04:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: THOMAS RESIDENCE Calculation Date/Time: 13:04, Tue, Dec 18, 2018
Calculation Description: Title 24 Analysis
Input File Name: 104 - LOT 24 AVENIDA RAMIREZ.ribd16x
CF1 R-PRF-01
Page 5 of 9
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12 13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
3056 - 19
12
0.1
12
12
0
0
0
0
0
0
0
0
0
6080 - 17
12 1
0.1
12
12
0
0
0
0
0
0
0
0
0
3056 - 17
12
0.1
12
12
0
0
0
0
0
0
0
0
0
3013-20
12
0.1
12
12
0
0
0
0
0
0
0
0
0
6013-18
12
0.1
12
12
0
0
0
0
0
0
0
0
0
3013-21
12
0.1
12
12
0
0
0
0
0
0
0
0
0
6080 - 1
2
0.1
2
2
0
0
0
0
0
0
0
0
0
3080 - 15
12
0.1
12
12
0
0
0
0
0
0
0
0
0
6013-16
12
0.1
12
12
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Constructlon Type
Framing
R-value
U-factor
Assembly Layers
Under Roof Joists: R-0.0 insul.
Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofZ1
Attic Roofs
Wood Framed Ceiling
in. O C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 + R-13
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Sheathing / Insulation: R13 Sheathing
• Cavity / Frame: R-38 / 2x4
• Roof Deck: Wood Siding/sheathing/decking
R-38 + R-131
Cathedral Ceilings
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
0.021
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
R-21 --
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
Registration Number: 218-P010332255A-000-000-0000000-0000 Registration Date/Time: 2018-12-18 13:13:02 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-18 13:04:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: THOMAS RESIDENCE Calculation Date/Time: 13:04, Tue, Dec 18, 2018
Calculation Description: Title 24 Analysis
Input File Name: 104 - LOT 24 AVENIDA RAMIREZ.ribdl6x
CF1 R-PRF-01
Page 6 of 9
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
20123
Z1
2012
0.1
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
+ 02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1 (1)
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Name
Heater
Element
Type
Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor / Energy
Factor / Efficiency
Input Rating /
Pilot /
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand / Model /
Other
Tank Location
or Ambient
Condition
DHW Heater 1
Gas
Small Storage
1
50
0.62 EF
<= 75 kBtu/hr
R-0/R-0
0
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC-Z11
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFurnace
1
80 AFUE
Registration Number: 218-P010332255A-000-000-0000000-0000 Registration Date/Time: 2018-12-18 13:13:02 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-18 13:04:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: THOMAS RESIDENCE Calculation Date/Time: 13:04, Tue, Dec 18, 2018
Calculation Description: Title 24 Analysis
Input File Name: 104 - LOT 24 AVENIDA RAMIREZ.ribd16x
CFI R-PRF-01
Page 7 of 9
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
I 07
08
Name
System Type
Number of Units
Efficiency
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
PkgAirCond
1
11
14
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
I Not Required
Not Required
Not Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification,
Air Distribution System 1
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
Registration Number: 218-P010332255A-000-000-0000000-0000 Registration Date/Time: 2018-12-18 13:13:02 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-18 13:04:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: THOMAS RESIDENCE Calculation DatefTime: 13:04, Tue, Dec 18, 2018
Calculation Description: Title 24 Analysis
Input File Name: 104 - LOT 24 AVENIDA RAMIREZ.ribd16x
CF1 R-PRF-01
Page 8 of 9
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
50
0.25
Default
0
Required
PROJECT NOTES
ALL EXISTING AND PROPOSED INPUT DATA USED IN THIS CALCULATION WAS PROVIDED BY THE PLANS PREPARER. ANY ALTERATION OR DEVIATION FROM THIS CALCULATION
WILL BE GENERAL CONTRACTOR RESPONSABILITY.
Registration Number: 218-P010332255A-000-000-0000000-0000 Registration Date/Time: 2018-12-18 13:13:02 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-18 13:04:58
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: THOMAS RESIDENCE Calculation Date/Time: 13:04, Tue, Dec 18, 2018
Calculation Description: Title 24 Analysis
Input File Name: 104 - LOT 24 AVENIDA RAMIREZ.ribdl6x
CF1 R-PRF-01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature
ARMANDO CHAVEZ
��`G
Company:
Signature Date:
TITLE 24 OF THE DESERT
2018-12-18 13:12:23
Address:
CEA/HERS Certification Identification (If applicable):
74800 Shirley #62
N.A.
City/State/Zip:
Phone:
PALM DESERT, CA 92260
760-278-1840
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets. calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature -
Ruben Romero
f�
Company:
Date Signed:
GLS ARCHITECTURE GROUP INC
2018-12-18 13:13:02
Address:
License:
74491 JONI DR SUITE #9
N.A.
City/State/Zip:
Phone:
Palm Desert, CA 92260
760-340-3528
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
Easy to Verify
at CaICERTS.com
Registration Number: 218-P010332255A-000-000-0000000-0000 Registration Date/Time: 2018-12-18 13:13:02
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149
HERS Provider: CaICERTS inc
Report Generated at: 2018-12-18 13:04:58
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name Building Type 0 Single Family ❑ Addition Alone
THOMAS RESIDENCE ❑ Multi Family ❑ Existing+ Addition/Alteration
Project Address California Energy Climate Zonl Cond. Floor Area Additi
LOT 24 AVENIDA RAMIREZ LA QUINTAL CA Climate Zone 15e Tota2, 012 n/a
Date
12/1812018on # of
Units
1
INSULATION
Construction Type
Cavity
Area
ftz Special Features
Status
Roof Wood Framed Attic
Slab Unheated Slab -on -Grade
Wall Wood Framed
R 38
- no insulation
R 21
2,005 Add=R-13 0 Cool Roof
2,012 Perim = 0'
1,615
New
New
New
FENESTRATION
Orientation Area(ft)
I Total Area: 330 Glazinn Percentage: 16.4%
U-Fac SHGC Overhang Sidefins
New/Altered Average U-Factor:
Exterior Shades
0.33
Status
Skylight 1.0
0.480
0.23 none
none
None
New
Skylight 1.0
0.480
0.23 none
none
None
New
Skylight 1.0
0.480
0.23 none
none
None
New
Skylight 1.0
a480
0.23 none
none
None
New
Skylight 1.0
0.480
0.23 none
none
None
New
Skylight 1.0
a480
0.23 none
none
None
New
Skylight 1.0
0.480
0.23 none
none
None
New
Left (N) 96.0
0.330
0.25 12.0
none
Bug Screen
New
Left (N) 35.0
0.330
0.25 none
none
Bug Screen
New
Rear (E) 35.5
0.330
0.25 none
none
Bug Screen
New
Right (S) 77.0
0.330
0.25 none
none
Bug Screen
New
Front (W) 48.0
0.330
0.25 2.0
none
Bug Screen
New
Front (W) 31.5
0.330
0.25 12.0
none
Bug Screen
New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat
Status
1 Central Furnace
80% AFUE
Packaged Air Condition 14.0 SEER
Setback
New
HVAC DISTRIBUTION
Location Heating
Cooling
Duct Location
Duct
R-Value
Status
HVAC-Z1 Ducted
WATER HEATING
Qty. Type
Ducted Attic 8.0
Gallons Min. Eff Distribution
New
Status
1 Small Storage Gas
50
0.62
Standard
New
EnarqyPro 7.1 by Ener Soft User Number.' 20M
ID: 2017-GLS-103
Pa e 12 of 17
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. "Exceptions may apply.
fOrinin2i f1R 9nis1
Building Envelope Measures:
§ 110.6(a)l:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfmlft' or less when tested per
NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 10l/I.S.2/A440-2011 '
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
§ 110.6(b):
110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.'
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
§ 110.7:
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emiftance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 110.8 i when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceiling.*
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value,
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or
§ 150.0(c):
less). Opaque non -framed assemblies must have,an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a
wood framed assembly.*
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.'
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 11g.$ .
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
§ 150.0(g)1:
requirement also applies to controlled ventilation crawls ace for buildings complying with the exceptiori to § 150.0(d).
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
§ 150.0(g)2:
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)lA:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1 B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)1 C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the buildin , are . rohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.'
§ 1102(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.'
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)5.
§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTUlhr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves afe Closed.
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool and spa heaters'
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)l-
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions s ecified in 150.0(h)2.
2016 Low -Rise Residential Mandatory Measures Summary
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
§ 150.0(h)3A:
dryer vent.
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
§ 150.0(h)3B:
manufacturer's instructions.
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
§ 150.00)1:
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures."
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
§ 150.00)2B:
and non -crushable casing or sleeve.'
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
§ 150.00)2C:
piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.-
§ 150.0@3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
§ 150.00)3B:
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
§ 150.0(n)1:
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance' and a Las supply line with a copwAy of at least 200,000 BtAir.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
§ 150.0(n)3:
Corporation SRCC or by a listing agency that is approved by the Executive Director.
Ducts and Fans Measures:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CIVIC). If a
§ 110.8(d)3:
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CIVIC
§§ 601,0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CIVIC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3,8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
§ 150.0(m)1:
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/< inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such toe is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
§ 150.0(m)7:
automatic dampers.
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
§ 150.0(m)8:
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0 m 11 and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of 150.0 m 12.
2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced air systems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
raVidi whole-buildingventilation,
§ 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating'
§ 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak. electric demand periods.
§ 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0 Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
§ (p)' rate, piping, filters and valves.'
Lighting Measures:
§ 110.9.. Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of§ 110.9.,
§ 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JA8_
§ 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for
elevated temperature must be installed by final Inspection in all recessed downll ht luminaires in ceilings.
§ 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
§ 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of 6 150.0(k).'
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8'
§ 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5(f); and meets all other requirements in § 150:0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5(1; and all other requirements in § 150.0(k)2.
§ 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
orovldes the functionality of a dimmer according to 4 110.9, and complies with all other applicable requirements in § 150.0(k)2.
NP 2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JA8 except luminaires in closets less than 70 square feet and luminaires in hallways.'
§ 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either 150.0 k 3A orwith the applicable requirements in 110.9,130.0, 130.2 130.4 140.7 and 141.0.
§ 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0 k 3B or § 150.0(k)30 most comply with the applicable requirements in §§ 110.9 130.0 130.2, 130.4 140.7 and 141.0.
§ 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must comply with the applicable requirements in §§ 11 0.9130.0.. 130.2, 130.44 140,7 and 141.0.
§ 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0(c).
§ 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garaes in 110.9 130.0,130.1, 130.4 140.E and 141.0,
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
buildlnq must be high efficacy luminaires and controlled §Y an Occupant ant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9,130.0,130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.10 b through § 110.10(e).
§ 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d),
Minimum Area. The solar zone must have a minimum total area as described below, The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1: greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
_ than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment'
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)313; distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical Oane.'
§ 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel): and a pathway for routing of plumbing from the solar zone to the water-heatin system.
§ 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
11 0.10c must be provided to the occupant.
§ 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric"
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
THOMAS RESIDENCE
12/18/2018
System Name
Floor Area
HVAC-Z1
2,012
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 798
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
COOLING PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
55,000
19,380
2,455
366
15,515
Total Output Btuh
55,000
0
Output Btuh/s ft
27.3
1,119
762
Cooling System
0
0
Output per System
58,000
0
0
0
0
Total Output Btuh
58,000
0
0
Total Output (Tons)
4.8
1,119
762
Total Output Stuh/s ft
28.8
TOTAL SYSTEM LOAD
2,455
Total Output s ft/Ton
416.3
21,617
17,040
Air System
CFM per System
5,700
HVAC EQUIPMENT SELECTION
Airflow cfm
5,700
4WCY406OB1000C
37,570
12,162
55,000
55,000
Jan 1 AM
Airflow cfm/s ft
2.83
Airflow cfm/Ton
1,179.3
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
Outside Air %
0.0%
37,570
12,162
Outside Air cfm/s ft
0.00
Note: values above given at ARI
conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF 70 OF 70 OF 110 OF
- 11N.
Outside Air
0 cfm Supply Fan Heating Coil
110 OF
5,700 cfm
ROOM
70 OF
70 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling
Peak
111 178 OF 78 / 62 OF 78 162 OF 55 / 54 OF
Q
Outside Air
0 cfm Supply Fan Cooling Coil
55154 °F
5,700 cfm
41.6% ROOM
78 / 62 of
78162 OF
EnergyPro 7.1 by EnergySoft User Number: 20648