Loading...
BRES2019-003378-495 CALLE TAMPICO D '111�fn, VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 3/20/2019 Permit Type/Subtype: BUILDING RESIDENTIAL/ADDITION Owner: Application Number: BRES2019-0033 GOETSCH BRETT ROLAND Property Address: 50795 CALLE RONDO 50795 CALLE RONDO APN: 770101004 LA QUINTA, CA 92253 Application Description: GOETSCH / 232SF ADDITION TO MASTER BEDROOM [ENGINEERED] Property Zoning: Application Valuation: $10,000.00 Applicant: Contractor: BRETT GOETSCH OWNER BUILDER 50795 CALLE RONDO MAR 2 0 2019 LA QUINTA, CA 92253 CITY OF LA QUINTA DESIGN & DEVELOPMENT DEPARTMENT Llc. No.: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a pe(rhit subjects the applicant to a civil penalty of not more than five hundred dollars I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold wi[[hin one year of Completion, the owner -builder will have the burden of proving that Tshe did not build or Improve for the purpose of sale.). rlf) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves th reon, and who contracts for the projects with a contractors) lie nsed pursuant to ontractor5' State License Law.). [ ) I am exempt under Sec. or this season Owner: CONSTRUCTION LENDING(AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Car ' � Policy Number: A1 certify that in the performance of the work for which this permit is issued, I shal not employ any person to any manner so as to become subject t the workers' compensation laws of California, and agree that, if I should become hject to the workers' compensation provisions of Selof th bor Co I shall rthwith comply with those provisions. !! Date, r Zv �' Applicant: WARNING: FAILURE TO SECURE WOR RS' COMPEN ION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2, Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating t uilding construction, and hereby authorize representatives of es city en upon above -mentioned property for inspection purposes. Date V "Z ' Signature (Applicant or �s r Application Number: BRES2019-0033 Owner: Date: 3/20/2019 Property Address: 50795 CALLE RONDO GOETSCH BRETT ROLAND APN: 770101004 50795 CALLE RONDO Application Description GOETSCH / 232SF ADDITION TO MASTER BEDROOM [ENGINEERED] LA QUINTA, CA 92253 Property Zoning: Application Valuation: $10,000.00 Applicant: Contractor: BRETT GOETSCH 50795 CALLE RONDO OWNER BUILDER LA QUINTA, CA 92253 Llc. No.: --------------------------------------------------------------------------------------------- Detail: 232SF ADDITION TO MASTER BEDROOM [ENGINEERED] THIS PERMIT DOES NOT INCLUDE REMODEL TO EXISTING RESIDENCE OR PLUMBING ALTERATIONS. 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNT CITY 101-0000-42600 DESCRIPTION ACCOUNT CITY DESCRIPTION DESCRIPTION ADDITION, EA ADDITIONAL 500 SF DESCRIPTION ADDITION, EA ADDITIONAL 500 SF PC DESCRIPTION ADDITION, FIRST 100 SF DESCRIPTION ADDITION, FIRST 100 SF DESCRIPTION ADDITION, FIRST 100 SF PC DESCRIPTION HOURLY CHARGE - ESGIL CIVIL ENGINEER 101-0000-42600 ACCOUNT QTY 101-0000-42600 ACCOUNT CITY 101-0000-42400 0 ACCOUNT QTY 101-0000-42600 0 ACCOUNT QTY 101-0000-42400 0 ACCOUNT CITY 101-0000-42400 0 ACCOUNT CITY 101-0000-42600 0 Total Paid for ADDITION: ACCOUNT OTY 101-0000-42600 1 2 Total Paid for BLDG CITY STAFF - PER HOUR: DESCRIPTION ACCOUNT CITY BSAS SB1473 FEE 101-0000-20306 0 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: DESCRIPTION ACCOUNT CITY RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 DESCRIPTION ACCOUNT CITY RESIDENTIAL, FIRST 1,0005F, PC 101-0000-42600 0 Total Paid for ELECTRICAL - NEW CONSTRUCTION: DESCRIPTION ACCOUNT CITY FURNACE 101-0000-42402 0 DESCRIPTION ACCOUNT QTY FURNACE PC 101-0000-42600 0 Total Paid for MECHANICAL: DESCRIPTION ACCOUNT QTY PLAN CHECK DEPOSIT - ADDITION/REMODEL 101-0000-42600 1 Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: DESCRIPTION ACCOUNT QTY RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: AMOUNT ($36.95) AMOUNT ($19.21) AMOUNT ($68.84) AMOUNT $68.84 AMOUNT $19.21 AMOUNT $36.95 AMOUNT $97.53 AMOUNT $188.92 $286.45 AMOUNT $210.00 $210.00 AMOUNT $1.00 $1.00 AMOUNT $160.10 AMOUNT $52.83 $212.93 AMOUNT $40.02 AMOUNT $26.68 $66.70 AMOUNT $125.00 $125.00 AMOUNT $21.00 $21.00 DESCRIPTION_ I ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 1101-0000-20308 0 $1.30 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1.30 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 rr r Project Address: ��� ���' alle APN #: Applicant Name: 9/-ff 6--oe&A i Address: cf® City, ST, Zip: 110 Telephone: 11/0 Email: Arch/Eng Name: Address: City, St, Zip Telephone: Email: State Lic: City Bus Lic: PERMIT # �j4� Z N ( Od 3 PLAN LOCATION: Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech �e✓N Dale! ��%fi ovl %� ��5��. Valuation of Project Construction Type: Grading: Bedrooms: I Stories: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 Occupancy: # Units: Date: 3/20/2019 No.: 19-01273-1 Owner: Goetsch Brett Roland Address: 50795 Calle Rondo City: La Quinta Type: Residential Addition < 500 sq ft CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 2Q Y 47950 Dune Palms Road Rneec+lo rh �(($��'• n I I4Ai170A i1KAL?I La Quinta, CA 92253 Y PAN Elk RT H` meuk"A (760)771-8515Q 1r�'1y� Lot # Street No. Street Name 50795 Calle Rondo Comments: Email: Jurisdiction: La Quinta Tract #: Sq. Feet APN Permit No. 232 770-101-004 or, 0 cV O 1ti � - Q At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less Exempt This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 232 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: Exempt/Brett Czoetsch Check No.: Bank Name/Recipient of Certificate Telephone: 310-415-0554 Funding: Exempt By Scott L. Bailey Superintendent Fee Collected/ Exempted by: Arianne Catano Certificate Fees Due: $0.00 Original Payment(s) Rec'd: $0.00 New Payment Rec'd: $0.00 X, / 0-ver/ under: $0.00 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you rr,zy protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District(`s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. ta 62aiwra GF.LI afsbr OFSFU, PROPERTY OWNER'S PACKAGE MAR 18 2919 Disclosures & Forms for Owner -Builders Applying forte Permits IMPORTANT! NOTICE TO RNPERTY OWNER Dear Property Owner: T An application for a d�1 f* permit for work within the public right-of-way has been submitted in vour a�r e lis 'ng urs if as the builder of the cdGivaw(+y improvements specified at ,$07V, 'C4 ie A* , v We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a driveway permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION DIRECTIONS: Read and initial each statement below to signify you understand or verify this information. understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. 1-11 R7. I understand driveway permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. 3. 1 understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit flied in his or her name instead of my own. E4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. ® 5. l understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. '4T 6-6- 6. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. N7. I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. W8. I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800-321-CSLB (2752) or www.cs[b.co.gov for more information about licensed contractors. ® 9. I am aware of and consent to an Owner -Builder driveway permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the following address: o _7 cl - c►4-cLe ROQbC) ® 10. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner -Builders as well as employers. ®11. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be .in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a driveway permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of property owner's driver's license, form notarization, or other verification acceptable to the agency is required to be prese ted when the permit is issued to verify the property owner's signotu Signature of property owner: _ _ _ Date: 78-495 Calle Tampico La Quinta, CA 92253 760.777.7000 Note: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHOR17ATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work): Ael,,ovI4 Project Location or Address: 6711e pr/("O Name of Authorized Agent: A �7f7 � VY, Tel No.l'�f� Address of Authorized Agent: �✓�S �O C7 �sA ��i?��" I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature. n Property Owner's Signature: Date: 78-495 Calle Tampico La Quinta, CA 92253 760.777.7000 CITY OF LA QUINTA SUB-CONTRACTORLIST JOB ADDRESS _1-079,5 c4u_E Ram PERMIT NUMBER'_1!>9. 2.ol°t__ya33 OWNER 6ci7SC(� _ -BUILDER d%,Q`VEV�_ This form shall be 1osted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance ..4C i- .;I.J;... ...,;+ I:— r. , k nnH; kin trorla nil ;-Fr rmnt;nn rantinctarl halnlni miict ha nmm1-0atar1 hkl annlicant `,nn Fib-" IS not an arrpntable resoonse. Workers C zsation Insurance City Business W ❑ Compensation License Trade,.[ Ci�sst(lation. Ca.ntraror State Contractor I €re�S... .. ... Company Name Classification (e.g. A, B, C-8) License Number (xxxxxx) Exp. Date (xx/),x/xx) Carrier Name (e.g. State Fund, CalComp) Policy Number Exp. Date License Number (Format Varies) (xx/xx/xx) (xxxx) Exp. Date (xx/xx/xx) EARTHWORK IC•12). CONCRETE (C-8) EC /'" FRAMING (C-5)'(_� TRUCT. STEEL.:(C 51): MAS:O:NRY (C 29:1 PLUMBING (C46.) LATH, -PLASTER. (.C-35) D13YWALL (C=9). HVAC (C120) ELECTRICAL (C=1 W HOOFING (C•39) S:H. EET :M:1=TAL (G-48) FLOORING (C-15) GLAZING (.C-17) INSULATION (C-2) SEWAGE DISP. (C-42) PAINTING (C-33) CERAMIC TILE (.0-54) CABINETS (C-6) FENCING (C=13) LANDSCAPING (C-27) POOL (C-53) Plan Submittal D Job Site Addr Owner's Na Number, Street, or PO I City, State, Postal C� Owner's Phone Num Owner's E-Mail Addr Project Manager's Na Project Manager's Phone Num Project Manager's E-mail Addr Builder / Contras Number, Street or PO I City, State, Postal C( Project Square Foot Building Permit Number: 52ot , Project Description: SFR Exempt: ❑ (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan 3/18/2019 50795 Calle Rondo Brett Goetsch 50795 Calle Rondo La Quinta, CA. 92253 310-415-0554 brett0m oatenco ro - con ) Ken Pugh 312-316-8330 Owner/Builder 50795 Calle Rondo La Quinta, CA. 92253 Approx. 232 sq ft City Approval By Renado Gouldlock-DEC/Burrtec Waste , 40 Date of City Approval 06 I / Q. I f Materials To Be Discarded: Product Tons 0.90 Not recyclable 0.00 Recyclable 0.00 Recyclable 0.00 Recyclable 0.00 Recyclable A0.00 RecyclablRecyclable Recyclable Trash Asphalt Brick/Block Cardboard Commingled Concrete Drywall Donated / Reuse" "Describe Items Totals: Recycle Trash 1.7 0.9 Product Masonry (broken) Plaster Scrap Metal Tile (floor) Tile (roof) Wood Landscape Debris Tons 0.00 Recyclable 0.29 Recyclable 0.00 Recyclable 0.03 Recyclable 0.03 Recyclable 0.25 Recyclable 0.00 Recyclable Projected Diversion: 65.65% I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer Owner / Developer / Project Manager / Superintendant Date BUILDING ENERGY ANALYSIS REPORT PROJECT: GOETSCH RESIDENCE's addition 50795 CALLE RONDO LA QUINTA, CA 92253 Project Designer: ROMMEL FUENTES 760 898-6603 Report Prepared by: Armando Chavez 44890 SEELEY LA QUINTA, CA 92253 760 278.1840 Job Number: 18-RML-001 Date: 2/9/2019 CITY 0E-LA-QUINTiA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE S1 I 0%0,5 a`i • ftl3 RECZ; I v rao FEB 12 &019 CITY CIF UA QUINTA COMMUNITY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. /Sr I TABLE OF CONTENTS I Cover Page Table of Contents Form CF-1 R-PRF-01-E Certificate of Compliance Form RMS-1 Residential Measures Summary 11 Form MF-1 R Mandatory Measures Summary 12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: GOETSCH RESIDENCE Calculation Daterrime: 19:35, Sat, Feb 09, 2019 Calculation Description: Title 24 Analysis Input File Name: 001 - 50795 CALLE RONDO.6bd16x CF1 R-PRF-01 Page 1 of 8 GENERAL INFORMATION 01 Project Name GOETSCH RESIDENCE 02 Calculation Description Title 24 Analysis 03 Project Location 50795 CALLE RONDO 04 City LA QUINTA 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version CBECC-Res 2016.3.1 (1019) 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 2067 15 Number of Zones 2 16 Slab Area (ft2) 2067 17 Number of Stories 1 18 Addition Cond. Floor Area (ft2) 232 19 Natural Gas Available Yes �20 Addition Slab Area (ft2) 232 21 Glazing Percentage (%) 11.0% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 3.23 3.42 -0.19 -5.9% Space Cooling 183.74 175.56 8.18 4.5% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 12.20 12.20 0.00 0.0% Photovoltaic Offset -- 0.00 0.00 --- Compliance Energy Total 199.17 191.18 7.99 4.0% Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-02-09 19:36:25 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: GOETSCH RESIDENCE Calculation Date/Time: 19:35, Sat, Feb 09, 2019 Calculation Description: Title 24 Analysis REQUIRED SPECIAL FEATURES Input File Name: 001 - 50795 CALLE R0ND0.ribd16x T�following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins • Exposed slab floor in conditioned zone • New ductwork added is less than 40 ft. in length HERS FEATURE SUMMARY CF1 R-PRF-01 Page 2 of 8 The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • —None— Cooling System Verifications: • —None — HVAC Distribution System Verifications: • —None — Domestic Hot Water System Verifications: • —None — BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems GOETSCH RESIDENCE 2067 1 2 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 A Conditioned HAVC1 1835 8 DHW Sys 1 n/a B Conditioned HAVC1 232 8 DHW Sys 1 n/a 771 Registration Number: Registration Date[Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-02-09 19:36:25 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: GOETSCH RESIDENCE Calculation Daterrime: 19:35, Sat, Feb 09, 2019 Calculation Description: Title 24 Analysis Input File Name: 001 - 50795 CALLE RONDO.ribd16x CF1 R-PRF-01 Page 3 of 8 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 11 Name Zone N - 220 A E - 420 A S - 346 A W - 216 A TO GARAGE A»B 1835 A N- 72 B21 S - 72 B21 W - 206 B Construction Def Wall '78 to '91 Def Wall 78 to '91 Def Wall 78 to '91 Def Wall '78 to '91 Def Wall Priorto 78 f '78 to Present INSUL INSUL nR-21INSUL Azimuth 0 90 180 270 0 180 270 Orientation Right Front Left Back Right Left Back Gross Area (ftZ) 220 420 346 216 125 1835 72 72 206 Window£ Door Tilt Area (ftZ) (deg) 0 90 122 90 9 90 80.999 90 0 p 90 0 90 t:��56 90 Wall Exception n/a n/a n/a n/a n/a n/a none none none Status Existing Existing Existing Existing Existing Existing New New New Verified Existing Condition No No No No No No n/a n/a n/a OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 1 10:New Name Zone 232 B Area Type Orientation (ft2) R-38 + R-12 Right 232 Skylight Area (ft2) 0 Roof Rise (z in 12) 0.2 Roof Roof Reflectance Emittance 0.86 0.88 Cool Roof Yes *n/a ATTIC 01 02 103 04 05 706 07 08 09 10 Name Construction Attic A Attic RoofA Type Ventilated Roof Rise 4 Roof Reflectance 0.1 Roof Emittance 0.85 Radiant Cool Barrier Roof No No Status Existing Verified Existing Condition No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-02-09 19:36:25 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: GOETSCH RESIDENCE Calculation Daterrime: 19:35, Sat, Feb 09, 2019 Page 4 of 8 Calculation Description: Title 24 Analysis Input File Name: 001 - 50795 CALLE RONDO.ribd16x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 Verified Existing Name Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ftZ) U-factor SHGC Exterior Shading Status Condition 8040 E - 420 (Front-90) 8.0 4.0 1 32.0 0.71 0.60 Insect Screen (default) Existing No 80402 E - 420 (Front-90) 8.0 4.0 1 32.0 0.71 0.60 Insect Screen (default) Existing No 6030 E - 420 (Front-90) 6.0 3.0 1 18.0 0.71 0.60 Insect Screen (default) Existing No 3030 S - 346 (Left-180) - - 1 9.0 0.71 0.60 1 Insect Screen (default) Existing No 5036 W - 216 (Back-270) 2.0 2.0 6.25 25.0 0.71 0.60 Insect Screen (default) Existing No 2040 W - 216 (Back-270) 2.0 4.0 1 8.0 0.71 0.60 Insect Screen (default) Existing No 6068 W - 216 (Back-270) 6.0 6.7 0.995 40.0 0.71 0.60 Insect Screen (default) Existing No 2040 2 W - 216 (Back-270) 2.0 4.0 1 8.0 0.71 0.60 Insect Screen (default) Existing No 20403 W - 206 (Back-270) - ----- 1 8.0 0.51 0.24 Insect Screen (default) New n/a 60682 W - 206 (Back-270) - -- 1 40.0 0.51 0.24 Insect Screen (default) New n/a 20404 W - 206 (Back-270) - -- 1 8.0 0.51 0.24 Insect Screen (default) New n/a OPAQUE DOORS 01 02 03 04 05 06 Side Building Area (ftZ) U-factor Status Verified Existing Condition Name of 60683 E - 420 40.0 0.50 Existing No OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 8040 4 0.1 4 4 0 0 0 0 0 0 0 0 0 80402 4 0.1 4 4 0 0 0 0 0 0 0 0 0 6030 4 0.1 4 4 0 0 0 0 0 0 0 0 0 5036 4 0.1 4 4 0 0 0 0 0 0 0 0 0 2040 4 0.1 4 4 0 0 0 0 0 0 0 0 0 6068 4 0.1 4 4 0 0 0 0 0 4 0 0 0 0 20402 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-02-09 19:36:25 CFI R-PRF-01 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Date/Time: 19:35, Sat, Feb 09, 2019 Page 5 of 8 Calculation Project Name: GOETSCH RESIDENCE Input File Name: 001 - 50795 CALLE RONDO.ribd16x Calculation Description: Title 24 Analysis OPAQUE SURFACE CONSTRUCTIONS 05 06 07 01 02 03 04 Total Cavity Winter Design Assembly Layers Type Construction Name Surface T Construction Type Framing R value U-factor Cavity /Frame: no insul. / 2x4 Top Chrd • Roof Deck: Wood Siding/sheathing/decking 2x4 Top Chord of Roof Truss-@ 24 p_400 • Tile Gap: FJr�ser�t Roofing: r- P5r (RoofTle) Attic RoofA Attic Roofs Wood Framed Ceiling in. O.C. none Inside Finish: Gypsum Board • Cavity / Frame: R-9.1 / 2x4 Ceilings (below 2x4 @ 24 in. O.C.attic R 19 0.049 Over Ceiling Joists: R-9.9 insul. Def Roof '78 to Present ) Wood Framed Ceiling Inside Finish: Gypsum Board • Cavity / Frame: R-11 / 2x4 R 11 0.110 Exterior Finish: 3 Coat Stucco Def Wall'78 to'91 Exterior Walls Wood Framed Wall 2x4 16 in. O.C. e Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 0.277 Other Side Finish: Gypsum Board Def Wall Prior to '78 Interior Walls Wood Framed Wall 2x4 °� 16 in. O.C. none Inside Finish: Gypsum Board Cavity/Frame: R-38/2x12 Roof Deck. Wood Siding/sheathing/decking Above Deck Insulation: R12 Sheathing R 38 0.021 Roofing: Light Roof (Asphalt Shingle) R-38 + R-12 Cathedral Ceilings Wood Framed Ceiling 2x12 @ 24 in. O.C. Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 121 0.069 Exterior Finish; 3 Coat Stucco R-21 INSUL Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. SLAB FLOORS 03 04 05 06 07 08 09 01 02 Verified Perimeter Carpeted Existing Edge Insul. R-value Fraction Heated Status Condition Name Zone Area (ft) (ft) None 0.8 No Existing No 18352 ANo 1835 01 None New No 0 B 232 0 1 2322 BUILDING ENVELOPE - HERS VERIFICATION 03 04 01 02 of Spray Foam Insulation Building Envelope Air Leakage CFM50 g Quality Insulation Installation (QII) Quality Installation Not Required n/a Not Required Not Required HERS Provider: Registration Date/Time:Registration Number: Report Generated at: 2019-02-09 19:36:25 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: GOETSCH RESIDENCE Calculation Date/Time: 19:35, Sat, Feb 09, 2019 Calculation Description: Title 24 Analysis Input File Name: 001 - 50795 CALLE RONDO.ribdl6x CF1 R-PRF-01 Page 6 of 8 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 0 Existing No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R-value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model Tank Location or Ambient Condition DHW Heater 1 Gas Small Storage 1 50 0.525 EF <= 75 kBtu/hr 0 n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Status Verified Existing Condition HAVC1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Existing No HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace 1 78 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 8.7 8.9 Not Zonal Single Speed Cooling Component 1-hers-cool Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-02-09 19:36:25 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: GOETSCH RESIDENCE CF1R-PRF-01 Calculation Date/Time: 19:35, Sat, Feb 09, 2019 Calculation Description: Title 24 Analysis Page 7 of 8 Input File Name: 001 - 50795 CALLE RONDO.ribd16x HVAC COOLING . HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified Refrigerant Cooling Component 1-hers-cool Verified SEER Not Required Charge HVAC -DISTRIBUTION SYSTEMS n/a Not Required Not Required Not Required 01 02 03 04 05 06 07 08 Insulation Supply Duct Return Duct 09 10 Name Type Duct Leakage R-value Verified Existing HERS Location Location Bypass Duct Status Air Distribution Ducts located in attic Condition Verification System 1 (Ventilated and Existing (not Unventilated specked) 8.0 Attic Attic None Existing + New No n/a IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Recoveryffectiveness°I° IAQ Watts/CFM IAQ Fan Type E SFam IAQVentRpt 0 I ) HERS Verification 0.25 PROJECT NOTES Default 0 Not Required --ALL pRDPDSEf3 INPUT t7ATA USED !N THfS CALCULATION WqS p}�pVlbi=D SY THE pLAfVS PREPARER, --ANY ALTERATION C3R OEViATIDN FRgiVI THIS CALCULATION WILL BE GENERAL CONTRACTOR RESPQNSA8ILITY, _ LOA[a CALCULATIONS ANp AC SIZING EQUIPMENT SHALL 13E VERIFIEt7 BY THE AC CDNTRACTfDR PRIOR TO PLACEMENT OF ITS oRf]ER. -- RC E{�LIIPMENT'S EFFICENCY SHALL BE EG�UAL (DR GETTER) THAN REt�UiREi7 BY TH15 REPORT. Registration Number: Registration CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Versionl CF1 R-06232018-1149 HERS Provider: Report Generated at: 2019-02-09 19:36:25 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: GOETSCH RESIDENCE Calculation Date/Time: 19:34, Sat, Feb 09, 2019 Calculation Description: Title 24 Analysis Input File Name: 001 - 50795 CALLE RONDO.ribd16x CF1 R-PRF-01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Armando Chavez Signature Date: Company: 2/9/2019 Address: CEA/HERS Certification Identification (If applicable): 44890 SEELEY City/State z�p.' :QU I NTA, CA 92253 Phone: 760 278.1840 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the Califomia Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Company: Date Signed: ROMMEL FUENTES Address: License: 760 898-6603 City/State/Zip: Phone: Registration Number: Registration Date/Tme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2019-02-09 19:34:40 RESIDENTIAL MEASURES SUMMARY Project Name Building Type ® Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration GOETSCH RESIDENCE'S addition California Energy Climate Zone Total Coed. Floor Area A232n Project Address 50795 CALLE RONDO LA QUINTA CA Climate Zone 15 2, 067 INSULATION Area ff Special Features Construction T e Cavit Slab Unheated Slab -on -Grade - no insulation 1,835 Perim = 0' Roof Wood Framed Attic R 19 1,835 Wall Wood Framed R 11 990 Door Opaque Door - no insulation 40 Demising Wood Framed - no insulation 125 232 Add=R-12.0 Cool Roof Roof Wood Framed Rafter R 38 Slab Unheated Slab -on -Grade - no insulation 232 Perim = 0' Wall Wood Framed R 21 294 11.0% NewlAltered Ave rs a LJ-Facto FENESTRATN Total Area: IO 228 G}a�in Percents e: Exterior Shades Orientation Area ff U-Fac SHGC OverhangSidefins 82.0 0.710 0.60 4.0 none Bug Screen Front (E) 9.0 0.710 0.60 none none Bug Screen Left (S) 81.0 0.710 0.60 4.0 none Bug Screen Rear (W 56.0 0.510 0.24 none none Bug Screen Rear (W) HVAC SYSTEMS Qty. Heating 1 Central Furnace Min. Eff Cooling Min. Eff 78% AFUE Split Air Conditioner 8.9 SEER HVAC DISTRIBUTION Location Heatin HA VC Ducted WATER HEATING Qtv. Tvpe Coolina Duct Location Ducted Attic Gallons Min. Eff Distribution RMS-1 Dates 2/9/2019 7#of Units 1 Status Existing � Existing Existing Existing Existing New New New 0.51 Status Existing � Existing Existing New Thermostat Status Setback Existing Duct R-Value Status 8.0 Altered Status 1 by EnerQVSoft User Number: 20646 !D- 18 - RML . 001 page 11 of 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply, Ori inai 08/2016 Building Envelope Measures: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfmlft' or less when tested per § 110.6(a)l: NFRC400 or ASTM E283 or AAMAIWDMAICSA 10111.5.21A440-2011 ' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). U-factors and solar heat gain coefficient (SHGC) values from TABLES Field fabricated exterior doors and fenestration products must use § 110.6(b): 110.6-A and 110.6-B for com fiance and must be caulked andlor weetherstri aed.' and other openings in the building envelope that are potential sources of air leakage must be caulked, § 110.7: Air Leakage. All joints, penetrations, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). and aged solar reflectance values of the roofing § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance material must meet the requirements of 110.8 i when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. in wood -frame ceiling; or the weighted average U-factor must not exceed 0,043. Calling and Rafter Roof Insulation. Minimum R-22 insulation average U-fa ctor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): Minimum R-19 or weighted insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent aif leakage. Insulation must be installed in exfiliration as specified in § 110.7, including but not limited direct contact with a continuous roof or ceiling which is sealed to limit infiltration and to lacing insulation either above or below the roof deck or on top of a dDLALall ceilin ' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a § 150.0(c): wood framed assembly.' § 150.0(d): Raised -floor Insulation. Minimum R 19 insulation in raised wood framed floor or 0.037 maximum U factor' have water absorption rate, for the insulation material alone without § 150.0(f): Slab Edge Insulation. Slab edge Insulation must meet all of the following: a than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch, be protected from physical damage and UV light facings, no greater deterioration; and, when installed as art of a heated slab floor, meet the re uirements of 110.8 . In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This § 150.0(g)l: Vapor Retarder. requirement also applies to controlled ventilation crawls ace for buildin s com I in with the exce tivn to 150.0 d . I Class II vapor retarder must be installed on the conditioned space side of all Vapor Retarder. In Climate Zones 14 and 16, a Class or § 150.0(g)2: insulation in all exterior walls vented attics, and unvented attics with air -permeable insulation. Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a 15 0.0 § (q) Fenestration maximum U factor of 0.58; or the wet hted avers a U4actor of all fenestration must not exceed 0.58' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)1 B: Combustion intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a read il accessible, operable, and ti ht-flttin damper or combustion -air control device.' § 150.0(e)1C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a fireboxjacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0 § 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified b the manufacturer to the Ener Commission: § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for su lementa heatin § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTUlhr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heatin systems to allow for water tank flushingwhen the valves are closed. Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central fumaces; household cooking appliances (appli § 110.5: ances without an electrical supply volla a connection with ilot li hts that consume less than 150 Btulhr are exempt); and ool and spa heaters. Building Cooling and bleating toads. Heating andlor cooling loads are calculated in accordance with ASHRAs= Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions s ecified in 150.0 h 2. 2016 Low -Rise Residential Mandata Measures Summa § 150.0(h)3A: Clearances. installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any d er vent. § 150.0(h)36: Liquid Line Drier. installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water heating systems, must have § 150.00)1: R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line Insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.0(j)2A: nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures.' § ing system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof 150.00)2B: Water piping and cool and non -crushable casin or sleeve' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 15D_0(j)2A. Distribution piping for steam and h dronic heati s stems or hot water s stems must meet the requirements in TABLE 120.3 A' § 150.O0)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation ofthe material. § 150.O0)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1. 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater and allows natural drainingwithout um assistance; and a as su i line with a ca acit of at least 200,000 Btulhr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be cerfifted and rated by the Solar Rating and Certification Corporation SRCC or bby a listing agency that is approved b the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § that oftheCalifornia Mechanical Code ( if a contractor installs the insulation, the contractor must certifyto the customer, in writing,that the insulation meets this requirement. CMC compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMG % 601.0. 602.0, 603.0, 604.0, 605.0 and ANSIlSMACNA-DD6.2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 for higher if required by CMG § 605.0) or a minimum installed level of R4.2 when entirely In conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/. inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and su ort Natforms must not be corn n ressed to cause reductions 1n the cross•sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct to es unless such toe is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressu re-s ensi live tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dam ers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible. manuals o erated dam ers in all o enin s to the outside, exce t combustion inlet and outlet air openings and elevator shLvents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)g: wind. Insulation exposed to weather must be suitable for outdoor service For example, protected by aluminum. sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. 'inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. § 150.0(m)10: Porous Inner Core Flex Duct. Porous itioning systems use forced air duct systems to supply conditioned air to an Duct System Sealing and Leakage Test. When space cond § 150.0(m)l1: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with 150.4 m 1 i and Reference Residential endix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of 150.0 m 12. YY ,:. 2016 Low -Rise Residential Mandatory Measures Summa Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy < 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of rovldin whole-bui Idi nq ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heatin .' § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heatin . § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow § (p)' rate. nioinn. filters. and valves' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JAB high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission accordin to Reference Joint A endix JAB. § 150.0(k)1A: Luminatre Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fanspeed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors, § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 1% k .' Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JAB. Installed lamps must be marked with "JAB-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JAB.' § 150.0(k)1H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JAB compliant and must be marked with "JAB-2016-E.' § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems' § 150.0(k)2C: Interior Switches and Controls. luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0 k . § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 ;and meets all other re uirements in 150.0 k 2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130,5ft and all other re uirements in 150.0 k 2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it ❑rovides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0 k 2. =2016 Low -Rise Residential Mandatary Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint ApRendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS). Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0 k 3A or with the applicable requirements it §§ 110,9,130.0.130.2,130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 39 or § 150.0 k 3D must comply with the applicable r uirements in §§ 110.9, 130.0, 130.2, 130.4. 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1. 130.4. 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fulIX on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1. application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of 110.10(b) through § 110.10(e). § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10ld), Minimum Area. The solar zone must have a minimum total area as described below The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted a ui ment.' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)313: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest 2oint of the solar zone, measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 110.10(c) must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and Lermanently marked as "For Future Solar Electric"