BRES2019-003378-495 CALLE TAMPICO D '111�fn, VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 3/20/2019
Permit Type/Subtype: BUILDING RESIDENTIAL/ADDITION Owner:
Application Number: BRES2019-0033 GOETSCH BRETT ROLAND
Property Address: 50795 CALLE RONDO 50795 CALLE RONDO
APN: 770101004 LA QUINTA, CA 92253
Application Description: GOETSCH / 232SF ADDITION TO MASTER BEDROOM [ENGINEERED]
Property Zoning:
Application Valuation: $10,000.00
Applicant:
Contractor:
BRETT GOETSCH OWNER BUILDER
50795 CALLE RONDO MAR 2 0 2019
LA QUINTA, CA 92253
CITY OF LA QUINTA
DESIGN & DEVELOPMENT DEPARTMENT Llc. No.:
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 70001 of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: License No.:
Date:
Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
pe(rhit subjects the applicant to a civil penalty of not more than five hundred dollars
I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
wi[[hin one year of Completion, the owner -builder will have the burden of proving that
Tshe did not build or Improve for the purpose of sale.).
rlf) 1, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
th reon, and who contracts for the projects with a contractors) lie nsed pursuant to
ontractor5' State License Law.).
[ ) I am exempt under Sec. or this season
Owner:
CONSTRUCTION LENDING(AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Car ' � Policy Number:
A1 certify that in the performance of the work for which this permit is issued, I
shal not employ any person to any manner so as to become subject t the workers'
compensation laws of California, and agree that, if I should become hject to the
workers' compensation provisions of Selof th bor Co I shall rthwith
comply with those provisions. !!
Date, r Zv �' Applicant:
WARNING: FAILURE TO SECURE WOR RS' COMPEN ION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2, Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating t uilding
construction, and hereby authorize representatives of es city en upon
above -mentioned property for inspection purposes.
Date V "Z ' Signature (Applicant or
�s
r
Application Number: BRES2019-0033 Owner: Date: 3/20/2019
Property Address: 50795 CALLE RONDO GOETSCH BRETT ROLAND
APN: 770101004 50795 CALLE RONDO
Application Description GOETSCH / 232SF ADDITION TO MASTER BEDROOM [ENGINEERED] LA QUINTA, CA 92253
Property Zoning:
Application Valuation: $10,000.00
Applicant: Contractor:
BRETT GOETSCH
50795 CALLE RONDO
OWNER BUILDER
LA QUINTA, CA 92253
Llc. No.:
---------------------------------------------------------------------------------------------
Detail: 232SF ADDITION TO MASTER BEDROOM [ENGINEERED] THIS PERMIT DOES NOT INCLUDE REMODEL TO EXISTING RESIDENCE OR PLUMBING
ALTERATIONS. 2016 CALIFORNIA BUILDING CODES.
DESCRIPTION ACCOUNT CITY
101-0000-42600
DESCRIPTION ACCOUNT CITY
DESCRIPTION
DESCRIPTION
ADDITION, EA ADDITIONAL 500 SF
DESCRIPTION
ADDITION, EA ADDITIONAL 500 SF PC
DESCRIPTION
ADDITION, FIRST 100 SF
DESCRIPTION
ADDITION, FIRST 100 SF
DESCRIPTION
ADDITION, FIRST 100 SF PC
DESCRIPTION
HOURLY CHARGE - ESGIL CIVIL ENGINEER
101-0000-42600
ACCOUNT
QTY
101-0000-42600
ACCOUNT
CITY
101-0000-42400
0
ACCOUNT
QTY
101-0000-42600
0
ACCOUNT
QTY
101-0000-42400
0
ACCOUNT
CITY
101-0000-42400
0
ACCOUNT
CITY
101-0000-42600
0
Total Paid for ADDITION:
ACCOUNT
OTY
101-0000-42600 1 2
Total Paid for BLDG CITY STAFF - PER HOUR:
DESCRIPTION
ACCOUNT CITY
BSAS SB1473 FEE
101-0000-20306 0
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA:
DESCRIPTION
ACCOUNT CITY
RESIDENTIAL, FIRST 1,000SF
101-0000-42403 0
DESCRIPTION
ACCOUNT CITY
RESIDENTIAL, FIRST 1,0005F, PC
101-0000-42600 0
Total Paid for ELECTRICAL - NEW CONSTRUCTION:
DESCRIPTION
ACCOUNT CITY
FURNACE
101-0000-42402 0
DESCRIPTION
ACCOUNT QTY
FURNACE PC
101-0000-42600 0
Total Paid for MECHANICAL:
DESCRIPTION
ACCOUNT QTY
PLAN CHECK DEPOSIT - ADDITION/REMODEL 101-0000-42600 1
Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL:
DESCRIPTION
ACCOUNT QTY
RECORDS MANAGEMENT FEE - MAJOR
101-0000-42416 0
Total Paid for RECORDS MANAGEMENT FEE - MAJOR:
AMOUNT
($36.95)
AMOUNT
($19.21)
AMOUNT
($68.84)
AMOUNT
$68.84
AMOUNT
$19.21
AMOUNT
$36.95
AMOUNT
$97.53
AMOUNT
$188.92
$286.45
AMOUNT
$210.00
$210.00
AMOUNT
$1.00
$1.00
AMOUNT
$160.10
AMOUNT
$52.83
$212.93
AMOUNT
$40.02
AMOUNT
$26.68
$66.70
AMOUNT
$125.00
$125.00
AMOUNT
$21.00
$21.00
DESCRIPTION_ I ACCOUNT QTY
AMOUNT
SMI - RESIDENTIAL 1101-0000-20308 0 $1.30
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1.30
DESCRIPTION ACCOUNT QTY AMOUNT
TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
rr r
Project Address: ��� ���' alle
APN #:
Applicant Name: 9/-ff 6--oe&A i
Address: cf®
City, ST, Zip: 110
Telephone: 11/0
Email:
Arch/Eng Name:
Address:
City, St, Zip
Telephone:
Email:
State Lic:
City Bus Lic:
PERMIT # �j4� Z N ( Od 3
PLAN LOCATION:
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
�e✓N Dale! ��%fi ovl %� ��5��.
Valuation of Project
Construction Type:
Grading:
Bedrooms: I Stories:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
Occupancy:
# Units:
Date: 3/20/2019
No.: 19-01273-1
Owner: Goetsch Brett Roland
Address: 50795 Calle Rondo
City: La Quinta
Type: Residential Addition < 500 sq ft
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
2Q Y
47950 Dune Palms Road
Rneec+lo rh �(($��'• n
I I4Ai170A i1KAL?I
La Quinta, CA 92253
Y PAN Elk RT H`
meuk"A
(760)771-8515Q
1r�'1y�
Lot # Street No. Street Name
50795 Calle Rondo
Comments:
Email:
Jurisdiction: La Quinta
Tract #:
Sq. Feet APN Permit No.
232 770-101-004
or,
0
cV
O
1ti �
- Q
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
Exempt
This certifies that school facility fess imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 232 S.F. or $0.00 have been paid for the property listed above and that building permits
and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Fees Paid By: Exempt/Brett Czoetsch Check No.:
Bank Name/Recipient of Certificate Telephone: 310-415-0554
Funding: Exempt
By Scott L. Bailey
Superintendent
Fee Collected/ Exempted by: Arianne Catano Certificate Fees Due: $0.00
Original Payment(s) Rec'd: $0.00
New Payment Rec'd: $0.00
X, / 0-ver/ under: $0.00
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you rr,zy protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District(`s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
ta 62aiwra
GF.LI afsbr OFSFU,
PROPERTY OWNER'S PACKAGE
MAR 18 2919
Disclosures & Forms for Owner -Builders Applying forte Permits
IMPORTANT! NOTICE TO RNPERTY OWNER
Dear Property Owner: T
An application for a d�1 f* permit for work within the public right-of-way has been
submitted in vour a�r e lis 'ng urs if as the builder of the cdGivaw(+y improvements
specified at ,$07V, 'C4 ie A* , v
We are providing you with an Owner -Builder Acknowledgment and Information
Verification Form to make you aware of your responsibilities and possible risk you may
incur by having this permit issued in your name as the Owner -Builder. We will not issue a
driveway permit until you have read, initialed your understanding of each provision,
signed, and returned this form to us at our official address indicated. An agent of the
owner cannot execute this notice unless you, the property owner, obtain the prior approval
of the permitting authority.
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION
DIRECTIONS: Read and initial each statement below to signify you understand or verify this
information.
understand a frequent practice of unlicensed persons is to have the property owner
obtain an "Owner -Builder" building permit that erroneously implies that the property
owner is providing his or her own labor and material personally. I, as an Owner -Builder,
may be held liable and subject to serious financial risk for any injuries sustained by an
unlicensed person and his or her employees while working on my property. My
homeowner's insurance may not provide coverage for those injuries. I am willfully acting
as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to
workers on my property.
1-11
R7. I understand driveway permits are not required to be signed by property owners
unless they are responsible for the construction and are not hiring a licensed Contractor to
assume this responsibility.
3. 1 understand as an "Owner -Builder" I am the responsible party of record on the
permit. I understand that I may protect myself from potential financial risk by hiring a
licensed Contractor and having the permit flied in his or her name instead of my own.
E4. I understand Contractors are required by law to be licensed and bonded in California
and to list their license numbers on permits and contracts.
® 5. l understand if I employ or otherwise engage any persons, other than California
licensed Contractors, and the total value of my construction is at least five hundred dollars
($500), including labor and materials, I may be considered an "employer" under state and
federal law.
'4T
6-6- 6. I understand if I am considered an "employer" under state and federal law, I must
register with the state and federal government, withhold payroll taxes, provide workers'
compensation disability insurance, and contribute to unemployment compensation for
each "employee." I also understand my failure to abide by these laws may subject me to
serious financial risk.
N7. I understand as an Owner -Builder if I sell the property for which this permit is issued, I
may be held liable for any financial or personal injuries sustained by any subsequent
owner(s) that result from any latent construction defects in the workmanship or materials.
W8. I understand I may obtain more information regarding my obligations as an
"employer" from the Internal Revenue Service, the United States Small Business
Administration, the California Department of Benefit Payments, and the California Division
of Industrial Accidents. I also understand I may contact the California Contractors' State
License Board (CSLB) at 1-800-321-CSLB (2752) or www.cs[b.co.gov for more information
about licensed contractors.
® 9. I am aware of and consent to an Owner -Builder driveway permit applied for in my
name, and understand that I am the party legally and financially responsible for proposed
construction activity at the following address:
o _7 cl - c►4-cLe ROQbC)
® 10. I agree that, as the party legally and financially responsible for this proposed
construction activity, I will abide by all applicable laws and requirements that govern
Owner -Builders as well as employers.
®11. I agree to notify the issuer of this form immediately of any additions, deletions, or
changes to any of the information I have provided on this form. Licensed contractors are
regulated by laws designed to protect the public. If you contract with someone who does
not have a license, the Contractors' State License Board may be unable to assist you with
any financial loss you may sustain as a result of a complaint. Your only remedy against
unlicensed Contractors may be .in civil court. It is also important for you to understand
that if an unlicensed Contractor or employee of that individual or firm is injured while
working on your property, you may be held liable for damages. If you obtain a permit as
Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or
not those Contractors are properly licensed and the status of their workers' compensation
insurance coverage.
Before a driveway permit can be issued, this form must be completed and signed by
the property owner and returned to the agency responsible for issuing the permit.
Note: A copy of property owner's driver's license, form notarization, or other verification
acceptable to the agency is required to be prese ted when the permit is issued to verify
the property owner's signotu
Signature of property owner: _ _ _ Date:
78-495 Calle Tampico La Quinta, CA 92253 760.777.7000
Note: The following Authorization Form is required to be completed by the property owner
only when designating an agent of the property owner to apply for a construction permit for
the Owner -Builder.
AUTHOR17ATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my
personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to
apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my
project.
Scope of Construction Project (or Description of Work): Ael,,ovI4
Project Location or Address: 6711e pr/("O
Name of Authorized Agent: A �7f7 � VY, Tel No.l'�f�
Address of Authorized Agent: �✓�S �O C7 �sA ��i?��"
I declare under penalty of perjury that I am the property owner for the address listed
above and I personally filled out the above information and certify its accuracy. Note: A
copy of the owner's driver's license, form notarization, or other verification acceptable to the
agency is required to be presented when the permit is issued to verify the property owner's
signature. n
Property Owner's Signature: Date:
78-495 Calle Tampico La Quinta, CA 92253 760.777.7000
CITY OF LA QUINTA SUB-CONTRACTORLIST
JOB ADDRESS _1-079,5 c4u_E Ram PERMIT NUMBER'_1!>9. 2.ol°t__ya33 OWNER 6ci7SC(� _ -BUILDER d%,Q`VEV�_
This form shall be 1osted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work
on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance
..4C i- .;I.J;... ...,;+ I:— r. , k nnH; kin trorla nil ;-Fr rmnt;nn rantinctarl halnlni miict ha nmm1-0atar1 hkl annlicant `,nn Fib-" IS not an arrpntable resoonse.
Workers C zsation Insurance City Business
W ❑ Compensation
License
Trade,.[ Ci�sst(lation.
Ca.ntraror
State Contractor I €re�S... .. ...
Company Name
Classification
(e.g. A, B, C-8)
License Number
(xxxxxx)
Exp. Date
(xx/),x/xx)
Carrier Name
(e.g. State Fund, CalComp)
Policy Number Exp. Date License Number
(Format Varies) (xx/xx/xx) (xxxx)
Exp. Date
(xx/xx/xx)
EARTHWORK IC•12).
CONCRETE (C-8)
EC /'"
FRAMING (C-5)'(_�
TRUCT. STEEL.:(C 51):
MAS:O:NRY (C 29:1
PLUMBING (C46.)
LATH, -PLASTER. (.C-35)
D13YWALL (C=9).
HVAC (C120)
ELECTRICAL (C=1 W
HOOFING (C•39)
S:H. EET :M:1=TAL (G-48)
FLOORING (C-15)
GLAZING (.C-17)
INSULATION (C-2)
SEWAGE DISP. (C-42)
PAINTING (C-33)
CERAMIC TILE (.0-54)
CABINETS (C-6)
FENCING (C=13)
LANDSCAPING (C-27)
POOL (C-53)
Plan Submittal D
Job Site Addr
Owner's Na
Number, Street, or PO I
City, State, Postal C�
Owner's Phone Num
Owner's E-Mail Addr
Project Manager's Na
Project Manager's Phone Num
Project Manager's E-mail Addr
Builder / Contras
Number, Street or PO I
City, State, Postal C(
Project Square Foot
Building Permit Number: 52ot ,
Project Description: SFR
Exempt: ❑
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
3/18/2019
50795 Calle Rondo
Brett Goetsch
50795 Calle Rondo
La Quinta, CA. 92253
310-415-0554
brett0m oatenco ro - con )
Ken Pugh
312-316-8330
Owner/Builder
50795 Calle Rondo
La Quinta, CA. 92253
Approx. 232 sq ft
City Approval By Renado Gouldlock-DEC/Burrtec Waste ,
40
Date of City Approval 06 I / Q. I f
Materials To Be Discarded:
Product Tons
0.90 Not recyclable
0.00 Recyclable
0.00 Recyclable
0.00 Recyclable
0.00 Recyclable
A0.00
RecyclablRecyclable
Recyclable
Trash
Asphalt
Brick/Block
Cardboard
Commingled
Concrete
Drywall
Donated / Reuse"
"Describe Items
Totals: Recycle Trash
1.7 0.9
Product
Masonry (broken)
Plaster
Scrap Metal
Tile (floor)
Tile (roof)
Wood
Landscape Debris
Tons
0.00 Recyclable
0.29 Recyclable
0.00 Recyclable
0.03 Recyclable
0.03 Recyclable
0.25 Recyclable
0.00 Recyclable
Projected Diversion:
65.65%
I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is
diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or
demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still
issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the
DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through
bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer
Owner / Developer / Project Manager / Superintendant
Date
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
GOETSCH RESIDENCE's addition
50795 CALLE RONDO
LA QUINTA, CA 92253
Project Designer:
ROMMEL FUENTES
760 898-6603
Report Prepared by:
Armando Chavez
44890 SEELEY
LA QUINTA, CA 92253
760 278.1840
Job Number:
18-RML-001
Date:
2/9/2019
CITY 0E-LA-QUINTiA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE S1 I
0%0,5 a`i • ftl3
RECZ; I v rao
FEB 12 &019
CITY CIF UA QUINTA
COMMUNITY DEVELOPMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
/Sr
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF-1 R-PRF-01-E Certificate of Compliance
Form RMS-1 Residential Measures Summary 11
Form MF-1 R Mandatory Measures Summary 12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: GOETSCH RESIDENCE Calculation Daterrime: 19:35, Sat, Feb 09, 2019
Calculation Description: Title 24 Analysis
Input File Name: 001 - 50795 CALLE RONDO.6bd16x
CF1 R-PRF-01
Page 1 of 8
GENERAL INFORMATION
01
Project Name
GOETSCH RESIDENCE
02
Calculation Description
Title 24 Analysis
03
Project Location
50795 CALLE RONDO
04
City
LA QUINTA
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
09
Software Version
CBECC-Res 2016.3.1 (1019)
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
90
12
Project Scope
Addition and/or Alteration
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
2067
15
Number of Zones
2
16
Slab Area (ft2)
2067
17
Number of Stories
1
18
Addition Cond. Floor Area (ft2)
232
19
Natural Gas Available
Yes
�20
Addition Slab Area (ft2)
232
21
Glazing Percentage (%)
11.0%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building DOES NOT require HERS Verification
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
3.23
3.42
-0.19
-5.9%
Space Cooling
183.74
175.56
8.18
4.5%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
12.20
12.20
0.00
0.0%
Photovoltaic Offset
--
0.00
0.00
---
Compliance Energy Total
199.17
191.18
7.99
4.0%
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-02-09 19:36:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: GOETSCH RESIDENCE Calculation Date/Time: 19:35, Sat, Feb 09, 2019
Calculation Description: Title 24 Analysis
REQUIRED SPECIAL FEATURES
Input File Name: 001 - 50795 CALLE R0ND0.ribd16x
T�following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cool roof
• Window overhangs and/or fins
• Exposed slab floor in conditioned zone
• New ductwork added is less than 40 ft. in length
HERS FEATURE SUMMARY
CF1 R-PRF-01
Page 2 of 8
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• —None—
Cooling System Verifications:
• —None —
HVAC Distribution System Verifications:
• —None —
Domestic Hot Water System Verifications:
• —None —
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
GOETSCH RESIDENCE
2067
1
2
2
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
A
Conditioned
HAVC1
1835
8
DHW Sys 1
n/a
B
Conditioned
HAVC1
232
8
DHW Sys 1
n/a 771
Registration Number: Registration Date[Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-02-09 19:36:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: GOETSCH RESIDENCE Calculation Daterrime: 19:35, Sat, Feb 09, 2019
Calculation Description: Title 24 Analysis Input File Name: 001 - 50795 CALLE RONDO.ribd16x
CF1 R-PRF-01
Page 3 of 8
OPAQUE SURFACES
01 02
03
04
05
06
07 08
09
10
11
Name Zone
N - 220 A
E - 420 A
S - 346 A
W - 216 A
TO GARAGE A»B
1835 A
N- 72 B21
S - 72 B21
W - 206 B
Construction
Def Wall '78 to '91
Def Wall 78 to '91
Def Wall 78 to '91
Def Wall '78 to '91
Def Wall Priorto 78
f '78 to Present
INSUL
INSUL
nR-21INSUL
Azimuth
0
90
180
270
0
180
270
Orientation
Right
Front
Left
Back
Right
Left
Back
Gross Area
(ftZ)
220
420
346
216
125
1835
72
72
206
Window£ Door Tilt
Area (ftZ) (deg)
0 90
122 90
9 90
80.999 90
0
p 90
0 90
t:��56 90
Wall
Exception
n/a
n/a
n/a
n/a
n/a
n/a
none
none
none
Status
Existing
Existing
Existing
Existing
Existing
Existing
New
New
New
Verified
Existing
Condition
No
No
No
No
No
No
n/a
n/a
n/a
OPAQUE SURFACES — Cathedral Ceilings
01 02
03 04
05
06
07
08 09
1 10:New
Name Zone
232 B
Area
Type Orientation (ft2)
R-38 + R-12 Right 232
Skylight
Area (ft2)
0
Roof Rise
(z in 12)
0.2
Roof Roof
Reflectance Emittance
0.86 0.88
Cool
Roof
Yes
*n/a
ATTIC
01 02
103
04
05
706
07 08
09
10
Name Construction
Attic A Attic RoofA
Type
Ventilated
Roof Rise
4
Roof
Reflectance
0.1
Roof
Emittance
0.85
Radiant Cool
Barrier Roof
No No
Status
Existing
Verified Existing
Condition
No
Registration Number: Registration Date/Time:
HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149
Report Generated at: 2019-02-09 19:36:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: GOETSCH RESIDENCE
Calculation Daterrime:
19:35, Sat, Feb 09, 2019
Page 4 of 8
Calculation Description: Title 24 Analysis
Input File Name: 001 - 50795 CALLE
RONDO.ribd16x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
Verified
Existing
Name
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multiplier
Area (ftZ)
U-factor
SHGC
Exterior Shading
Status
Condition
8040
E - 420 (Front-90)
8.0
4.0
1
32.0
0.71
0.60
Insect Screen (default)
Existing
No
80402
E - 420 (Front-90)
8.0
4.0
1
32.0
0.71
0.60
Insect Screen (default)
Existing
No
6030
E - 420 (Front-90)
6.0
3.0
1
18.0
0.71
0.60
Insect Screen (default)
Existing
No
3030
S - 346 (Left-180)
-
-
1
9.0
0.71
0.60
1 Insect Screen (default)
Existing
No
5036
W - 216 (Back-270)
2.0
2.0
6.25
25.0
0.71
0.60
Insect Screen (default)
Existing
No
2040
W - 216 (Back-270)
2.0
4.0
1
8.0
0.71
0.60
Insect Screen (default)
Existing
No
6068
W - 216 (Back-270)
6.0
6.7
0.995
40.0
0.71
0.60
Insect Screen (default)
Existing
No
2040 2
W - 216 (Back-270)
2.0
4.0
1
8.0
0.71
0.60
Insect Screen (default)
Existing
No
20403
W - 206 (Back-270)
-
-----
1
8.0
0.51
0.24
Insect Screen (default)
New
n/a
60682
W - 206 (Back-270)
-
--
1
40.0
0.51
0.24
Insect Screen (default)
New
n/a
20404
W - 206 (Back-270)
-
--
1
8.0
0.51
0.24
Insect Screen (default)
New
n/a
OPAQUE DOORS
01
02
03
04
05
06
Side Building
Area (ftZ)
U-factor
Status
Verified Existing Condition
Name
of
60683
E - 420
40.0
0.50
Existing
No
OVERHANGS AND FINS
01
02 03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
8040
4
0.1
4
4
0
0
0
0
0
0
0
0
0
80402
4
0.1
4
4
0
0
0
0
0
0
0
0
0
6030
4
0.1
4
4
0
0
0
0
0
0
0
0
0
5036
4
0.1
4
4
0
0
0
0
0
0
0
0
0
2040
4
0.1
4
4
0
0
0
0
0
0
0
0
0
6068
4
0.1
4
4
0
0
0
0
0
4
0
0
0
0
20402
4 0.1 4
4 0 0
0
0
0 0
0
0 0
Registration Number:
Registration Date/Time:
HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report
Version - CF1 R-06232018-1149
Report Generated at: 2019-02-09 19:36:25
CFI R-PRF-01
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Date/Time: 19:35, Sat, Feb 09, 2019
Page 5 of 8
Calculation
Project Name: GOETSCH RESIDENCE
Input File Name: 001 - 50795 CALLE RONDO.ribd16x
Calculation Description: Title 24 Analysis
OPAQUE SURFACE CONSTRUCTIONS
05 06
07
01 02
03
04
Total Cavity Winter Design
Assembly Layers
Type
Construction Name Surface T
Construction Type
Framing
R value U-factor
Cavity /Frame: no insul. / 2x4 Top Chrd
• Roof Deck: Wood Siding/sheathing/decking
2x4 Top Chord of Roof Truss-@ 24
p_400
• Tile Gap: FJr�ser�t
Roofing: r- P5r (RoofTle)
Attic RoofA Attic Roofs
Wood Framed Ceiling
in. O.C.
none
Inside Finish: Gypsum Board
• Cavity / Frame: R-9.1 / 2x4
Ceilings (below
2x4 @ 24 in. O.C.attic
R 19 0.049
Over Ceiling Joists: R-9.9 insul.
Def Roof '78 to Present )
Wood Framed Ceiling
Inside Finish: Gypsum Board
• Cavity / Frame: R-11 / 2x4
R 11 0.110
Exterior Finish: 3 Coat Stucco
Def Wall'78 to'91 Exterior Walls
Wood Framed Wall
2x4 16 in. O.C.
e
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
0.277
Other Side Finish: Gypsum Board
Def Wall Prior to '78 Interior Walls
Wood Framed Wall
2x4 °� 16 in. O.C.
none
Inside Finish: Gypsum Board
Cavity/Frame: R-38/2x12
Roof Deck. Wood Siding/sheathing/decking
Above Deck Insulation: R12 Sheathing
R 38 0.021
Roofing: Light Roof (Asphalt Shingle)
R-38 + R-12 Cathedral Ceilings
Wood Framed Ceiling
2x12 @ 24 in. O.C.
Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
121 0.069
Exterior Finish; 3 Coat Stucco
R-21 INSUL Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
SLAB FLOORS
03 04
05
06 07 08 09
01
02
Verified
Perimeter
Carpeted Existing
Edge Insul. R-value Fraction Heated Status Condition
Name
Zone
Area (ft) (ft)
None
0.8 No Existing No
18352
ANo
1835 01
None
New No
0
B
232 0 1
2322
BUILDING ENVELOPE - HERS VERIFICATION
03
04
01
02
of Spray Foam Insulation
Building Envelope Air Leakage CFM50
g
Quality Insulation Installation (QII)
Quality Installation
Not Required
n/a
Not Required
Not Required
HERS Provider:
Registration Date/Time:Registration Number: Report Generated at: 2019-02-09 19:36:25
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: GOETSCH RESIDENCE Calculation Date/Time: 19:35, Sat, Feb 09, 2019
Calculation Description: Title 24 Analysis
Input File Name: 001 - 50795 CALLE RONDO.ribdl6x
CF1 R-PRF-01
Page 6 of 8
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
0
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Name
Heater
Element
Type
Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor / Energy
Factor / Efficiency
Input Rating /
Pilot /
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand / Model
Tank Location
or Ambient
Condition
DHW Heater 1
Gas
Small Storage
1
50
0.525 EF
<= 75 kBtu/hr
0
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution
Name
Status
Verified Existing
Condition
HAVC1
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution
System 1
Existing
No
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFurnace
1
78 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Name
System Type
Number of Units
Efficiency
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
1
8.7
8.9
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-02-09 19:36:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: GOETSCH RESIDENCE CF1R-PRF-01
Calculation Date/Time: 19:35, Sat, Feb 09, 2019
Calculation Description: Title 24 Analysis Page 7 of 8
Input File Name: 001 - 50795 CALLE RONDO.ribd16x
HVAC COOLING . HERS VERIFICATION
01 02
03 04 05
06
Name Verified Airflow Airflow Target Verified EER Verified Refrigerant
Cooling Component 1-hers-cool Verified SEER
Not Required Charge HVAC -DISTRIBUTION SYSTEMS n/a
Not Required Not Required Not Required
01 02 03 04
05 06 07 08
Insulation Supply Duct Return Duct
09 10
Name Type Duct Leakage R-value Verified Existing HERS
Location Location Bypass Duct Status
Air Distribution Ducts located in attic Condition Verification
System 1 (Ventilated and Existing (not
Unventilated specked) 8.0 Attic Attic
None Existing + New No n/a
IAQ (Indoor Air Quality) FANS
01 02
03 04 05
06
Dwelling Unit IAQ CFM IAQ Recoveryffectiveness°I°
IAQ Watts/CFM IAQ Fan Type E
SFam IAQVentRpt 0 I ) HERS Verification
0.25 PROJECT NOTES Default 0
Not Required
--ALL pRDPDSEf3 INPUT t7ATA USED !N THfS CALCULATION WqS p}�pVlbi=D SY THE pLAfVS PREPARER, --ANY ALTERATION C3R OEViATIDN FRgiVI THIS CALCULATION WILL BE
GENERAL CONTRACTOR RESPQNSA8ILITY, _ LOA[a CALCULATIONS ANp AC SIZING EQUIPMENT SHALL 13E VERIFIEt7 BY THE AC CDNTRACTfDR PRIOR TO PLACEMENT OF ITS
oRf]ER. -- RC E{�LIIPMENT'S EFFICENCY SHALL BE EG�UAL (DR GETTER) THAN REt�UiREi7 BY TH15 REPORT.
Registration Number:
Registration
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Versionl CF1 R-06232018-1149
HERS Provider:
Report Generated at: 2019-02-09 19:36:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: GOETSCH RESIDENCE Calculation Date/Time: 19:34, Sat, Feb 09, 2019
Calculation Description: Title 24 Analysis
Input File Name: 001 - 50795 CALLE RONDO.ribd16x
CF1 R-PRF-01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Armando Chavez
Signature Date:
Company:
2/9/2019
Address:
CEA/HERS Certification Identification (If applicable):
44890 SEELEY
City/State z�p.' :QU I NTA, CA 92253
Phone: 760 278.1840
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the Califomia Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Company:
Date Signed:
ROMMEL FUENTES
Address:
License:
760 898-6603
City/State/Zip:
Phone:
Registration Number: Registration Date/Tme: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2019-02-09 19:34:40
RESIDENTIAL MEASURES SUMMARY
Project Name
Building Type
® Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
GOETSCH RESIDENCE'S addition
California Energy Climate Zone
Total Coed. Floor Area A232n
Project Address
50795 CALLE RONDO LA QUINTA
CA Climate Zone 15
2, 067
INSULATION
Area
ff Special Features
Construction T e
Cavit
Slab Unheated Slab -on -Grade
- no insulation
1,835 Perim = 0'
Roof Wood Framed Attic
R 19
1,835
Wall Wood Framed
R 11
990
Door Opaque Door
- no insulation
40
Demising Wood Framed
- no insulation
125
232 Add=R-12.0 Cool Roof
Roof Wood Framed Rafter
R 38
Slab Unheated Slab -on -Grade
- no insulation
232 Perim = 0'
Wall Wood Framed
R 21
294
11.0% NewlAltered Ave rs a LJ-Facto
FENESTRATN Total Area:
IO
228 G}a�in
Percents e:
Exterior Shades
Orientation Area ff U-Fac
SHGC OverhangSidefins
82.0 0.710
0.60 4.0
none Bug Screen
Front (E)
9.0 0.710
0.60 none
none Bug Screen
Left (S)
81.0 0.710
0.60 4.0
none Bug Screen
Rear (W
56.0 0.510
0.24 none
none Bug Screen
Rear (W)
HVAC SYSTEMS
Qty. Heating
1 Central Furnace
Min. Eff Cooling Min. Eff
78% AFUE Split Air Conditioner 8.9 SEER
HVAC DISTRIBUTION
Location Heatin
HA VC Ducted
WATER HEATING
Qtv. Tvpe
Coolina Duct Location
Ducted Attic
Gallons Min. Eff Distribution
RMS-1
Dates
2/9/2019
7#of Units
1
Status
Existing
�
Existing
Existing
Existing
Existing
New
New
New
0.51
Status
Existing
�
Existing
Existing
New
Thermostat Status
Setback Existing
Duct
R-Value Status
8.0 Altered
Status
1 by EnerQVSoft User Number: 20646
!D- 18 - RML . 001 page 11 of
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. 'Exceptions may apply,
Ori inai 08/2016
Building Envelope Measures:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfmlft' or less when tested per
§ 110.6(a)l:
NFRC400 or ASTM E283 or AAMAIWDMAICSA 10111.5.21A440-2011 '
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
U-factors and solar heat gain coefficient (SHGC) values from TABLES
Field fabricated exterior doors and fenestration products must use
§ 110.6(b):
110.6-A and 110.6-B for com fiance and must be caulked andlor weetherstri aed.'
and other openings in the building envelope that are potential sources of air leakage must be caulked,
§ 110.7:
Air Leakage. All joints, penetrations,
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
and aged solar reflectance values of the roofing
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance
material must meet the requirements of 110.8 i when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
in wood -frame ceiling; or the weighted average U-factor must not exceed 0,043.
Calling and Rafter Roof Insulation. Minimum R-22 insulation
average U-fa ctor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
Minimum R-19 or weighted
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent aif leakage. Insulation must be installed in
exfiliration as specified in § 110.7, including but not limited
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and
to lacing insulation either above or below the roof deck or on top of a dDLALall ceilin '
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a
less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a
§ 150.0(c):
wood framed assembly.'
§ 150.0(d):
Raised -floor Insulation. Minimum R 19 insulation in raised wood framed floor or 0.037 maximum U factor'
have water absorption rate, for the insulation material alone without
§ 150.0(f):
Slab Edge Insulation. Slab edge Insulation must meet all of the following: a
than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch, be protected from physical damage and UV light
facings, no greater
deterioration; and, when installed as art of a heated slab floor, meet the re uirements of 110.8 .
In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
§ 150.0(g)l:
Vapor Retarder.
requirement also applies to controlled ventilation crawls ace for buildin s com I in with the exce tivn to 150.0 d .
I Class II vapor retarder must be installed on the conditioned space side of all
Vapor Retarder. In Climate Zones 14 and 16, a Class or
§ 150.0(g)2:
insulation in all exterior walls vented attics, and unvented attics with air -permeable insulation.
Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
15 0.0
§ (q)
Fenestration
maximum U factor of 0.58; or the wet hted avers a U4actor of all fenestration must not exceed 0.58'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1 B: Combustion intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a read il accessible, operable, and ti ht-flttin damper or combustion -air control device.'
§ 150.0(e)1C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a fireboxjacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0 § 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified b the manufacturer to the Ener Commission:
§ 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for su lementa heatin
§ 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)5.
§ 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTUlhr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heatin systems to allow for water tank flushingwhen the valves are closed.
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central fumaces; household cooking appliances (appli
§ 110.5: ances without an electrical supply volla a connection with ilot li hts that consume less than 150 Btulhr are exempt); and ool and spa heaters.
Building Cooling and bleating toads. Heating andlor cooling loads are calculated in accordance with ASHRAs= Handbook, Equipment
§ 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions s ecified in 150.0 h 2.
2016 Low -Rise Residential Mandata Measures Summa
§ 150.0(h)3A: Clearances. installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
d er vent.
§ 150.0(h)36: Liquid Line Drier. installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water heating systems, must have
§ 150.00)1: R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line Insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.0(j)2A: nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade, and all hot water pipes from the heating source to
kitchen fixtures.'
§ ing system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
150.00)2B: Water piping and cool
and non -crushable casin or sleeve'
§ 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 15D_0(j)2A. Distribution
piping for steam and h dronic heati s stems or hot water s stems must meet the requirements in TABLE 120.3 A'
§ 150.O0)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation ofthe material.
§ 150.O0)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)1. 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater and allows natural drainingwithout um assistance; and a as su i line with a ca acit of at least 200,000 Btulhr.
§ 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be cerfifted and rated by the Solar Rating and Certification
Corporation SRCC or bby a listing agency that is approved b the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § that oftheCalifornia Mechanical Code ( if a
contractor installs the insulation, the contractor must certifyto the customer, in writing,that the insulation meets this requirement.
CMC compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMG
% 601.0. 602.0, 603.0, 604.0, 605.0 and ANSIlSMACNA-DD6.2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 for higher if required by CMG § 605.0) or
a minimum installed level of R4.2 when entirely In conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/. inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and su ort Natforms must not be corn n ressed to cause reductions 1n the cross•sectional area of the ducts.'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
to es unless such toe is used in combination with mastic and draw bands.
§ 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressu re-s ensi live tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dam ers.
§ 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible.
manuals o erated dam ers in all o enin s to the outside, exce t combustion inlet and outlet air openings and elevator shLvents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)g: wind. Insulation exposed to weather must be suitable for outdoor service For example, protected by aluminum. sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
'inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
§ 150.0(m)10: Porous Inner Core Flex Duct. Porous
itioning systems use forced air duct systems to supply conditioned air to an
Duct System Sealing and Leakage Test. When space cond
§ 150.0(m)l1: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with 150.4 m 1 i and Reference Residential endix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of 150.0 m 12.
YY ,:.
2016 Low -Rise Residential Mandatory Measures Summa
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy < 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced airs stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
rovldin whole-bui Idi nq ventilation.
§ 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heatin .'
§ 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar heatin .
§ 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0 Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
§ (p)' rate. nioinn. filters. and valves'
Lighting Measures:
§ 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of § 110.9'
§ 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JAB high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission accordin to Reference Joint A endix JAB.
§ 150.0(k)1A: Luminatre Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fanspeed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors,
§ 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 1% k .'
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1 G: with Reference Joint Appendix JAB. Installed lamps must be marked with "JAB-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JAB.'
§ 150.0(k)1H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JAB compliant and must be marked with "JAB-2016-E.'
§ 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems'
§ 150.0(k)2C: Interior Switches and Controls. luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0 k .
§ 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5 ;and meets all other re uirements in 150.0 k 2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130,5ft and all other re uirements in 150.0 k 2.
§ 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
❑rovides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0 k 2.
=2016 Low -Rise Residential Mandatary Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint ApRendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.'
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS).
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either § 150.0 k 3A or with the applicable requirements it §§ 110,9,130.0.130.2,130.4, 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0 k 39 or § 150.0 k 3D must comply with the applicable r uirements in §§ 110.9, 130.0, 130.2, 130.4. 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1. 130.4. 140.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fulIX on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1.
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of 110.10(b) through § 110.10(e).
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10ld),
Minimum Area. The solar zone must have a minimum total area as described below The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted a ui ment.'
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)313:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest 2oint of the solar zone, measured in the vertical lane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.10(c) must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and Lermanently marked as "For Future Solar Electric"