BRES2018-037678-495 CALLE TAMPICO T4ht
UVOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Permit Type/Subtype: BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED Owner:
Application Number: BRES2018-0376 BR GROUP
Property Address: 54765 AVENIDA JUAREZ 54765 AVENIDA JUAREZ
APN: 774265031 LA QUINTA, CA 92253
Application Description: SIMONS / 2,568SF SINGLE FAMILY DWELLING
Property Zoning: ^
Application Valuation: $168,960.70 I`L•Jjk
?DApplicant: Contractor:
CORONEL ENTERPRISES INC APR 2 5 2019 CORONEL ENTERPRISES INC
42760 MADIO STREET 42760 MADIO STREET
INDIO, CA 92201 CITY OF LA QUINTA INDIO, CA 92201
DESIGN & DEVELOPMENT DEP,rtRTMENT (760)775-1234
Llc. No.: 727199
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 70001 of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B License No.: 7 7 99
Date'ntractor:
_�,_,A, CZn=:,Q
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
() I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
() I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C, for this reason
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Add
Date: 4/25/2019
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of tr for which this permit is issued.
! have and will maintain workers' compensation insurance, as required by
Section 700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: BENCHMARK INSURANCE COMPANY _ Policy Number: CST5014903 —
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section of he Labor Code, I shWVVrthwith
comply with those provisions.
Date: Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct,
I agree to comply with all city and county ordinances and state laws relating to bui g
construction, and hereby authorize representatives oftcity enter u the
above-mentioned property for inspection purposes.
Date: `i -•S -(9 `1 Signature (Applicant or Agent .
Application Number:
BRES2018-0376
Property Address:
54765 AVENIDA JUAREZ
APN:
774265031
Application Description:
SIMONS / 2,568SF SINGLE FAMILY DWELLING
Property Zoning:
Application Valuation:
$168,960.70
Applicant:
CORONEL ENTERPRISES INC
42760 MADIO STREET
INDIO, CA 92201
Owner:
BR GROUP
54765 AVENIDAJUAREZ
LA QUINTA, CA 92253
Contractor:
CORONEL ENTERPRISES INC
42760 MADIO STREET
INDIO, CA 92201
(760)775-1234
Llc. No.: 727199
Date: 4/25/2019
---------------------------------------------------------------------------------------------
Detail: 2,568SF DWELLING - [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2016
CALIFORNIA BUILDING CODES.
DESCRIPTION ACCOUNT QTY AMOUNT
BSAS SB1473 FEE 101-0000-20306 0 $7.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $7.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - CIVIC CENTER
252-0000-43200
0
$942.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - COMMUNITY CENTERS
254-0000-43200
0
$129.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - FIRE PROTECTION
257-0000-43200
0
$433.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - LIBRARIES
253-0000-43200
0
$344.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - PARK MAINTENANCE
256-0000-43200
0
$40.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - PARKS/REC
251-0000-43200
0
$2,048.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - STREET MAINTENANCE
255-0000-43200
0
$116.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - TRANSPORTATION
250-0000-43200
0
$2,842.00
Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SERVICES
101-0000-42403
0
$26.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SERVICES PC
101-0000-42600
0
$13.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TEMP POWER SERVICE
101-0000-42403
0
$26.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TEMP POWER SERVICE PC
101-0000-42600
0
$18.68
Total Paid for ELECTRICAL: $85.38
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF
101-0000-42403
0
$40.83
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF, PC
101-0000-42600
0
$16.80
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$160.10
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$52.83
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $270.56
DESCRIPTION ACCOUNT QTY AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF 101-0000-42408 0 $40.02
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF PC
101-0000-42600
0
$40.02
Total Paid for GRADING: $80.04
DESCRIPTION
ACCOUNT
CITY
AMOUNT
CONDENSER/COMPRESSOR
101-0000-42402
0
$80.04
DESCRIPTION
ACCOUNT
CITY
AMOUNT
CONDENSER/COMPRESSOR PC
101-0000-42600
0
$53.36
DESCRIPTION
ACCOUNT
CITY
AMOUNT
EXHAUST HOOD
101-0000-42402
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
EXHAUST HOOD PC
101-0000-42600
0
$5.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FURNACE
101-0000-42402
0
$80.04
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FURNACE PC
101-0000-42600
0
$53.36
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN
101-0000-42402
0
$53.36
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN PC
101-0000-42600
0
$21.36
Total Paid for MECHANICAL: $360.20
DESCRIPTION
ACCOUNT
CITY
AMOUNT
MULTI -SPECIES RESIDENTIAL 0-8 UNITS - 2018 UPDATE
101-0000-20310
0
$1,290.00
Total Paid for MULTI -SPECIES RESIDENTIAL: $1,290.00
DESCRIPTION ACCOUNT
CITY
AMOUNT
NEW CONSTRUCTION PERMIT 101-0000-42400
0
$614.54
Total Paid for NEW CONSTRUCTION PERMIT: $614.54
DESCRIPTION ACCOUNT QTY AMOUNT
NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,268.19
Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,268.19
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PLAN CHECK DEPOSIT- RESIDENTIAL
101-0000-42600
1
$750.00
Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $750.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BACKFLOW DEVICE
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BACKFLOW DEVICE PC
101-0000-42600
0
$5.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$160.08
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$160.08
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 5+ OUTLETS
101-0000-42401
0
$40.02
DESCRIPTION
ACCOUNT
QTY
AMOUNT
GAS SYSTEM, 5+ OUTLETS PC
101-0000-42600
0
$26.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SEPTIC SYSTEM
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SEPTIC SYSTEM PC
101-0000-42600
0
$13.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER HEATER/VENT
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER HEATER/VENT PC
101-0000-42600
0
$8.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$13.34
Total Paid for PLUMBING FEES. $480.24
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$21.97
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $21.97
DESCRIPTION
ACCOUNT QTY AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611 0 $5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
101-0000-42600
($750.00)
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SINGLE FAMILY DETACHED 2018 UPDATE
224-0000-20320
0
$750.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SINGLE FAMILY DETACHED 2018 UPDATE
224-0000-20320
0
$1,560.00
Total Paid for TUMF - RESIDENTIAL: $1,560.00
CERTIFICATE OF COMPLIANCE
Nor+gib
SC�0
Desert Sands Unified School District
}
r"�
47950 Dune Palms Road
"","'•'111, =
I; cuu n1•r e
Date: 4/22/2019 La Quinta, CA 92253
r .:- H
`0 .; T;',i
No.: 19-01309-1 (760)771-8515°
Owner: Coronel Enterprises
Address: 42760 Madio St
City: Indio
Type: Single Family Residential
Email:
Jurisdiction: Indio
Tract #:
Lot # Street No. Street Name Sq. Feet APN Permit No.
54-765 Avenida Juarez 2568 774-265-031
Comments:
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fess imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $3.79 X 2568 S.F. or $9,732.72 have been paid for the property listed above and that building
permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Fees Paid By: CCCaI' iia BanY,Lftr�.f-�.i.:..5.ir.7�c�ris
Bank Name/Recipient of Certificate
By Scott L. Bailey
Superintendent
Fee Collected/ Exempted by: Arianne Catano
Check No.: 608470
Telephone: 510-918-5020
Funding: Residential
Certificate Fees Due: $9,732.72
Original Payment(s) Recd: $0.00
New Payment Rec'd: $9,732.72
Over/Under: $0.00
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
RECORDING REQUESTED BY
Lawyers Title - IE
WHEN RECORDED MAIL THIS DOCUMENT
AND TAX STATEMENTS TO:
BR Group, a California Limited Partnership
1330 Neptune Avenue
I.eucadia, CA 92024
APN: 774-265-031-3
Escrow No: PDLISS93-LT139-NB
Title No: 618690888
rR A ' O 20- O I J` GRANT DEED
DOC # 2018-0089589
03/08/2018 04:34 PM Fees: $37.00
Page 1 of 2
Recorded in Official Records
County of Riverside
Peter Aldana
Assessor -County Clerk -Recorder
"This document was electronically submitted
to the County of Riverside for recording"
Receipted by: MARY #420
Space above this line for Recorder's use
THE UNDERSIGNED GRANTOR(S) DECLARE(S)
DOCUMENTARY TRANSFER TAX IS $165.00
® computed on full value of property conveyed
® City of La Qulnta
IM Exempt from fee per GC 27388.1 (a) (2); recorded concurrently in connection with a transfer subject to
the Imposition of documentary transfer tax , AND
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged,
Sergio Mejia, Trustee and Mary L. Mejia, Trustee of The Mejia Trust dated February 26, 2003
hereby GRANT(S) to
BR Group, a California Limited Partnership
the following described real property in the County of Riverside, State of CALIFORNIA.-
For
ALIFORNIA:For legal description of the real property herein, see Exhibit A attached hereto and
made a part hereof.
Commonly known as: APN 774-265-031-3 , La Quinta, CA 92253
Dated: Marc}, 2016
The M Ir'ust dated February 26, 2003
APR 10 2019
By: Mary r.�Nejla,
A notary public or other officer completing this certificate verifies only the Identity of the Individual who signed the
document to which this certificate Is attached, and not the truthfulness, accuracy, or validity of that document.
STATE OF CALIFORNIA )
�n �
COUNTY OF �/�,(/� i t )SS.
On 1 TMP before me, Notary Public, personally
appearedL1
who proved to me n the basis of satisfactory evidence to be the person(s) whose name(s) Is/are subscribed to
the within Instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized
capaclty(les), and that by hls/her/their signature(s) on the instrument the person(s), or the entity upon behalf of
which the person(s) acted, executed the Instrument.
I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph Is true
and correct.
WITNESS my hand and official seal.
Signature
_& J�4 A '9—
mail -fvl al oi(reS
5. Gl1ERPA
Notary Public . California
Riverside County a
Z
ComMfg SIort # 2:6$91 1 a
4 COMM. Expires NOY 3, 2020
4 L0 le—o-
Exhibit A
THE LAND REFERRED TO HEREIN IS SITUATED IN THE COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AND IS
DESCRIBED AS FOLLOWS:
LOT 1 AND THE NORTH 1/2 OF LOT 2, BLOCK 275, OF SANTA CARMELITA AT VALE LA QUINTA, UNIT NO. 25, IN THE
CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS SHOWN ON FILE IN BOOK 19, PAGES 50
AND 51, OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY.
ASSESSOR'S PARCEL NUMBER: 774-265-031-3
Building Permit Number: EOCSZQI - 0 370
Project Description: SFR
Exempt: r_1
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
Plan Submittal Date I 4/23/2019
Job Site Address I 54-765 Avenida Juarez
owners Neme
Dr. Robi Simons
Number, Street, or PO Box
54-765 Avenida Juarez
City, State, Postal Code
La Quinta, Ca. 92253
Owners Phone Number
c/o 760-775-1234
Owners E -Mail Add
Project Managers
Project Manager's Phone N
Project Managers E-mail Ai
Builder/ Contractor
Number, Street or PO Box
City, State, Postal Code
Project Square Footage
Ish Coronel
760-775-1234
co ro n e lvffice0corone le nt,co m
Coronel Enterprises
42760 Madio St
Indio, Ca. 92201
Approx. 2,568 sq ft
RECEIVED
APR 2 5 2019
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
City Approval By Renado Gouldlock-DEC/Buntec Wast
i��P,&awo�--�-)
Date of City Approval
Is To Be Discarded:
Product
Trash
Asphalt
Brick/Block
Cardboard
Commingled
Concrete
Drywall
Donated / Reuse*
`Describe Items
Tons
10.25 Not recyclable
0.00 Recyclable
0.00 Recyclable
0.00 Recyclable
0.00 Recyclable
11.25 Recyclable
1.25 Recyclable
0.00 Recyclable
Totals: Recycle Trash
1 20.01 F 10.3
Product
Masonry (broken)
Plaster
Scrap Metal
Tile (floor)
Tile (roof)
Wood
Landscape Debris
Tons
0.00 Recyclable
3.00 Recyclable
0,00 Recyclable
0.15 Recyclable
0.35 Recyclable
4.00 Recyclable
0,00 Recyclable
Projected Diversion:
66.12%
I understand it Is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste Is
diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP is issued in the name of the props owners) and shall remain their property throughout the construction and/or
demolition project. A contractor serving as agsnl of the owner may obtain a DMP for the owner. However, the DMP is still
issued in the name of the property oner(s) and the owner retains legal responsibility for ensuring that the provisions of the
QMP,are adhered to. The•property o ner(s)'and general contractor shall be kept informed of the diversion progress through
bl-mo lhly reports. If elf -hauling, all refused material from this project site must be taken to an approved recycler or transfer
Manager! S rintendant Dale
kro5p-241 F$ OW 0 31 to
BUILDING ENERGY ANALYSIS REPORT
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE Z Z g'y
RECE-NeD
PROJECT:
Dr. Robbi D Simons
34765 Avenida Juarez
La Quinta, Ca 92253
Project Designer:
Santiago Lopez Ocampo - Drafting & Design
P.O. Box 1018
La Quinta, Ca 92247
760.485.8927
Report Prepared by:
SLO
Santiago Lopez-Ocampo
P.O. Box 1018
La Quinta, Ca 92247
760.485.8927
SHgbs AI/ENlUA 00JOuAkE2
Job Number:
LQ 110518
Date:
FEB 0 6 2019
1/29/2019 coon;
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software - www.energysoft.com.
GI
42
TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form .CF -1 R -PRF -01-E Certificate of Compliance 3
Form RMS -1 Residential Measures Summary 11
Form MF -1 R Mandatory Measures Summary 13
j HVAC System Heating and Cooling Loads Summary 17
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Dr. Robbi D Simons
Calculation Description: Title 24 Analysis
Calculation Date/Time: 09:06, Tue, Jan 29, 2019
Input File Name: Dr. Simons - 54765 Avenida Juarez - Rev010919.ribd16x
CFI R -PRF -01
Page 1 of 8
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
0.64
1.95
-1.31
-204.7%
Space Cooling
80.09
71.28
8.81
11.0%
IAQ Ventilation
1.00
1.00
0.00
0.0%
Water Heating
5.06
4.36
0.70
13.8%
Photovoltaic Offset
0.00
0.00
—
Compliance Energy Total
86.79
78.59
8.20
9.4%
Registration Number: 218-Po10300033C-000-000-0000000-0000 Registration Date/Time: 2019-01-29 11:43:47 HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-29 09:08:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Dr. Robbi D Simons Calculation Date/Time: 09:06, Tue, Jan 29, 2019
Calculation Description: Title 24 Analysis
Input File Name: Dr Simons - 54765 Avenida Juarez - Rev010919 ribdl6x
CF1 R -PRF -01
Page 2 of 8
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency
EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR
53.2
49.5 0.0 49.5
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on-site photovoltaic (PV)
renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified.
Notes:
• Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cool roof
• Insulation below roof deck
• Exposed slab floor in conditioned zone
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
• -- None --
Registration Number: 218-Po10300033C-000-000-0000000-0000 Registration Date/Time: 2019-01-29 11:43:47 HERS Provider: CaiCERTs inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-01162019-1149 Report Generated at: 2019-01-29 09:08:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Dr Robbi D Simons Calculation Date/Time: 09:06, Tue, Jan 29, 2019
Calculation Description: Title 24 Analysis
Input File Name: Dr. Simons - 54765 Avenida Juarez - Rev010919.ribd16x
CFI R -PRF -01
Page 3 of 8
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Dr- Robbi D Simons
2568
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Whole House
Conditioned
HVAC System1
2568
11
DHW Sys 1
n/a
OPAQUE SURFACES
01
02
03
04
05
06
07
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ftZ)
Window & Door Area (ft)
Tilt (deg)
East
Whole House
R-21 Wall + 1 EPS
90
Front
210
95
90
South
Whole House
R-21 Wall + 1 EPS
180
Left
507
79.17
90
West
Whole House
R-21 Wall + 1 EPS
270
Back
490.41
134
90
North
Whole House
R-21 Wall + 1 EPS
0
Right
770
348.5
90
Interior Surface
Whole House
R-21 Wall
n/a
n/a
587.58
0
n/a
Roof 2
Whole House
R-38 HP Attic Option B w/
n/a
n/a
2551.76
n/a
n/a
OPAQUE SURFACES — Cathedral Ceilings
01
02
03
04
05
06
07
08
09
10
Name
Zone
Type
Orientation
Area (ft)
Skylight Area
(ft2)
Roof Rise
(x in 12)
Roof
Reflectance
Roof
Emittance
Cool Roof
Roof
Whole House
R-38 HP Attic Option B w/1
Left
1634
16.24
0.2
0.6
0.89
Yes
ATTIC
01
02 03 04 05 06 07 08
Name
Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Whole House
Attic RoofWhole House Unventilated 0.2 06 0.89 No Yes
Registration Number: 218-P010300033C-000-000-0000000-0000 Registration Date/Time: 2019-01-29 11:43:47 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-29 09:08:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Dr. Robbi D Simons Calculation Date/Time: 09:06, Tue, Jan 29, 2019
Calculation Description: Title 24 Analysis
Input File Name: Dr. Simons - 54765 Avenida Juarez - Rev010919.ribd16x
CF1 R -PRF -01
Page 4 of 8
FENESTRATION / GLAZING
01
02
03
04 05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Height
Width (ft) (ft)
Multiplier
Area
(ft)
U -factor
SHGC
Exterior Shading
10080 XXO MasterBed
Window
East (Front -90)
1
80.0
0.42
0.23
Insect Screen (default)
10016 FIX MasterBed
Window
East (Front -90)
- -
1
15.0
0.26
0.23
Insect Screen (default)
3040 SH Laundry
Window
South (Left -180)
1
12.0
0.27
0.25
Insect Screen (default)
3016 FIX Laundry
Window
South (Left -180)
1
4.5
0.26
0.23
Insect Screen (default)
5040 XO Bed 2
Window
South (Left -180)
1
20.0
0.27
0.25
Insect Screen (default)
5016 FIX Bed2
Window
South (Left -180)
--
1
7.5
0.26
0.23
Insect Screen (default)
2040 SH Bath2
Window
South (Left -180)
1
8.0
0.27
0.25
Insect Screen (default)
2016 FIX Bath2
Window
South (Left -180)
1
3.0
0.26
0.23
Insect Screen (default)
2854 Glass Block
Window
South (Left -180)
1
14.2
0.51
0.66
Insect Screen (default)
5020 FIX Bed3
Window
South (Left -180)
1
10.0
0.26
0.23
Insect Screen (default)
6080 SGD Bed3
Window
West (Back -270)
1
48.0
0.41
0.31
Insect Screen (default)
6016 FIX Bed2
Window
West (Back -270)
- --
1
9.0
0.26
0.23
Insect Screen (default)
3040 SH Office
Window
West (Back -270)
- --
1
12.0
0.40
0.24
Insect Screen (default)
3016 FIX Office
Window
West (Back -270)
- -
1
45
1 0.26
0.23
Insect Screen (default)
3080 FrDr GreatRoom
Window
West (Back -270)
-
1
24.0
0.29
0.21
Insect Screen (default)
3016 FIX GreatRoom
Window
West (Back -270)
----
1
4.5
0.26
0.23
Insect Screen (default)
4040 FIX GreatRoom
Window
West (Back -270)
-•-- ----
1
16.0
0.26
0.23
Insect Screen (default)
4040 FIX GreatRoom 2
Window
West (Back -270)
--- ---
1
16.0
0.26
0.23
Insect Screen (default)
16080 XXXO GreatRoom
Window
North (Right -0)
- -
1
128.0
0.42
0.23
Insect Screen (default)
16016 FIX Bed2
Window
North (Right -0)
---- •••.
1
24.0
0.26
0.23
Insect Screen (default)
3080 FrDr GreatRoom 2
Window
North (Right -0)
---- ----
1
24.0
0.29
0.21
Insect Screen (default)
3016 FIX GreatRoom 2
Window
North (Right -0)
---- ••••
1
4.5
0.26
0.23
Insect Screen (default)
10050 OXXO Kitchen
Window
North (Right -0)
1
50.0
0.40
0-24
Insect Screen (default)
10016 FIX Kitchen
Window
North (Right -0)
---- ---
1
15.0
0.26
0.23
Insect Screen (default)
4020 FIX MBath
Window
North (Right -0)
---- --
1
8.0
0.26
0-23
Insect Screen (default)
10080 XXO MasterBed 2
Window
North (Right -0)
---- •-••
1
80-0
0.42
0-23
Insect Screen (default)
10016 FIX MasterBed 2
Window
North (Right -0)
----
1
15.0
0.26 1
0.23
Insect Screen (default)
Velux FCM 2222 MBath
Skylight
Roof (Left -180)
1
3.5
0.48
0.27
Velux FCM 2222 MBath 2
Skylight
Roof (Left -180)
1
3.5
0.48
0-27
Registration Number: 218-P010300033C-000-000-0000000-0000 Registration DateRme: 2019-01-29 11:43:47 HERS Provider:
CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-29 09:08:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Dr Robbi D Simons Calculation Date/Time: 09:06, Tue, Jan 29, 2019
Calculation Description: Title 24 Analysis
Input File Name: Dr. Simons - 54765 Avenida Juarez - Rev010919.ribd16x
CF1 R -PRF -01
Page 5 of 8
Velux FCM 2222 Hallway Skylight Roof (Left -180) 1 3.5 0.48 0.27
Velux FCM 2222 Hallway 2 Skylight Roof (Left -180) 1 3.5 0.48 0.27
10 Solatube MCloset Skylight Roof (Left -180) 1 .5 0.51 022
10 Solatube Pantry Skylight Roof (Left -180) 1 .5 0.51 022
10 Solatube Bath2 Skylight Roof (Left -180) 1 .5 0.51 0.22
10 Solatube Powder. Skylight Roof (Left -180) 1 5 1 0.51 0.22
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R -value & Depth
Total Cavity
Winter Design
Slab -on -Grade
Construction Name
Surface Type
Construction Type
Framing
R -value
U -factor
Assembly Layers
Whole House
1000
0.1
None
1
No
• Around Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofWhole House
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0 078
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
Cavity/Frame: R-21 /2x6
Sheathing/ Insulation: R4.2 Sheathing
R-21 Wall + 1 EPS
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C-
R 21
0.050
Exterior Finish: 3 Coat Stucco
Inside Finish: Gypsum Board
Cavity/ Frame: R-21 / 2x6
R-21 Wall
Interior Walls
Wood Framed Wall
2x6 @ 16 in. 0 C
R 21
0.064
Other Side Finish: Gypsum Board
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 HP Attic Option B w/
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Sheathing /Insulation: R13 Sheathing
Cavity / Frame: R-38 / 2x4
• Roof Deck: Wood Siding/sheathing/decking
R-38 HP Attic Option B w/1
Cathedral Ceilings
Wood Framed Ceiling
2x4 @ 24 in. O.0
R 38
0.021
Roofing: Light Roof (Asphalt Shingle)
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R -value & Depth
Carpeted Fraction
Heated
Slab -on -Grade
Whole House
1568
0.1
None
0
No
Slab -on -Grade 2
Whole House
1000
0.1
None
1
No
Registration Number: 218-P010300033C-000-000-0000000-0000 Registration DateFl-ime: 2019-01-29 11:43:47 HERS Provider:
CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-29 09:08:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Dr. Robbi D Simons Calculation Date/Time: 09:06, Tue, Jan 29, 2019
Calculation Description: Title 24 Analysis
Input File Name: Dr. Simons - 54765 Avenida Juarez - Rev010919.ribd16x
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required n/a
CF1 R -PRF -01
Page 6 of 8
WATER HEATING SYSTEMS
01 02 03 04 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 DHW Standard DHW Heater 1 (1) 1 .0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Compressor
Type
HERS
Verification
HSPF/COP
Cap 47
Cap 17 SEER
I EER
Input Rating /
Tank
Standby
8.4
42500
29750 15
12
Heater
Single Speed
Heat Pump System
1 -hers -cool
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
NEEA Heat Pump
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R -value
Recovery
Rating /
Brand / Model /
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor/ Efficiency
Efficiency
(IntlExt)
Eff
Flow Rate
Other
Condition
DHW Heater 1
Gas
Small
1
0
0.95 EF
<= 200 kBtu/hr
R -0/R-0
0
n/a
n/a
n/a
Instantaneous
SPACE CONDITIONING SYSTEMS
01
01
02 03 04 05 06
SC Sys Name
System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name
HVAC Systeml
Heat Pump Heating and Heat Pump System 1 Heat Pump System 1 HVAC Fan 1 Air Distribution System 1
Cooling System
HVAC - HEAT PUMPS
01
02
03
04 05 ' 06 07 08
09
10
11
Name
System
Type
Number of
Units
Heating Cooling
Zonally
Controlled
Compressor
Type
HERS
Verification
HSPF/COP
Cap 47
Cap 17 SEER
I EER
Heat Pump System 1
SplitHeatPump
2
8.4
42500
29750 15
12
Not Zonal
Single Speed
Heat Pump System
1 -hers -cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Heat Pump System 1 -hers -cool
Required
350
Required
Required
Required
Registration Number: 218-P010300033C-000-000-0000000-0000 Registration Date/Time: 2019-01-29 11:43:47 HERS Provider: CaiCERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-01-29 09:08:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Dr. Robbi D Simons Calculation Date/Time: 09:06, Tue, Jan 29, 2019
Calculation Description: Title 24 Analysis
Input File Name: Dr. Simons - 54765 Avenida Juarez - Rev010919.ribd16x
CF1 R -PRF -01
Page 7 of 8
HVAC - DISTRIBUTION SYSTEMS
01
02 03
04
05 06 07
Name
Type Duct Leakage
Insulation R -value
Duct Location Bypass Duct HERS Verification
Air Distribution System 1
DuctsAttic Specified Lower Leakage
Target
8
Attic None Air Distribution System
1 -hers -dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1 -hers -dist
Required
50
Not Required
Not Required
Not Required
Not Required
Required
HVAC -FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM) HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan Required 0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
56
025
Default
0
Required
Registration Number: 218-Po10300033C-000-000-0000000-0000 Registration DateRme: 2019-01-29 11:43:47 HERS Provider:
CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-29 09:08:23
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Dr Robbi D Simons
Calculation Description: Title 24 Analysis
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Company:
Santiago Lopez-Ocampo
Address:
P.O. Box 1018
City/State/Zip:
La Quinta, CA 92247
RESPONSIBLE PERSON'S DECLARATION STATEMENT
Calculation DatefTime: 09:06, Tue, Jan 29, 2019
Input File Name: Dr. Simons - 54765 Avenida Juarez - Rev010919 ribd16x
Documentation Author Sior,a;wr
Signature Date:
2019-01-29 11:43:47
CEA/HERS Certification Identification (If applicable):
NA
Phone:
760-485-8927
CFI R -PRF -01
Page 8 of 8
I certify the following under penalty of perjury, under the laws of the State of California:
I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name: Responsible Designer Signature
Santiaoo Looez-Ocarnno
Company:
Santiago Lopez-Ocampo
Address:
P.O. Box 1018
City/State/Zip:
La Quinta, CA 92247
Date Signed:
2019-01-29 11:43:47
License:
NA
Phone:
760-485-8927
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 218-P010300033C-000-000-0000000-0000 Registration DateRme: 2019-01-2911:43:47
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149
Easy to Verify
at CaICERTS.com
HERS Provider: CaICERTS inc.
Report Generated at: 2019-01-29 09:08:23
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Dr. Robbi D Simons
Building Type
m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1/29/2019
Project Address
54765 Avenida Juarez La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area Addition
2,568 n/a
# of Units
1
INSULATION
Construction Type
Cavity
Area
( e) Special Features Status
Slab Unheated Slab -on -Grade
- no insulation
2,568 Perim = 0'
New
Wall Wood Framed
R 21
1,321 Add=R-4.2
New
Demising Wood Framed
R 21
588
New
Roof Wood Framed Attic
R 38
2,552 Add=R-13.0 Cool Roof New
FENESTRATION
Orientation Area(ft)
I Total Area: 673 Glazing Percenla e: 26-2
U -Fac SHGC Overhang Sidefins
New/Altered Avera ge U -Factor: 0-37
Exterior Shades Status
Front (E) 80.0
0-420 0.23 none
none
Bug Screen New
Front (E) 15.0
0.260 0.23 none
none
Bug Screen New
Left (S) 20.0
0.270 0.25 none
none
Bug Screen New
Left (S) 25.0
0.260 0.23 none
none
Bug Screen New
Left (S) 20.0
0.270 0.25 none
none
Bug Screen New
Left (S) 14.2
0.510 0.66 none
none
Bug Screen New
Rear (W) 48.0
0.410 0.31 none
none
Bug Screen New
Rear (W) 50.0
0.260 0.23 none
none
Bug Screen New
Rear (W 12.0
0.400 0.24 none
none
Bug Screen New
Rear (W) 24.0
0.290 0.21 none
none
Bug Screen New
Right (N) 208.0
0.420 0.23 none
none
Bug Screen New
Right (N) 66.5
0.260 0.23 none
none
Bug Screen New
Right (N) 24.0
0.290 0.21 none
none
Bug Screen New
Right (N) 50.0
0.400 0.24 none
none
Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
2 Split Heat Pump
8.40 HSPF
Split Heat Pump 15.0 SEER
Setback New
HVAC DISTRIBUTION
Location Heating
Cooling
Duct Location
Duct
R -Value Status
HVAC System Ducted
Ducted
Attic
8.0 New
WATER HEATING
Qty. Type
.......... _... -
Gallons Min. Eff Distribution Status
1 Small Instantaneous Gas
0
0.95
Standard
New
Ener Pro 7.2 by Enea7.vSoft User Number: 5732
ID: LQ110518 Pae 11 of 17
RESIDENTIAL MEASURES SUMMARY
I
0.37
Sidefins
Project Name
Dr. Robbi D Simons
Building Type m Single Family ❑ Addition Alone
RMS -1
Date
Project Address
❑ Multi Family
❑Existing+ Addition/Alteration
1/29/2019
54765 Avenida Juarez La Quints
California Energy Climate Zone
CA Climafe Zone 15
Total Cond. Floor Area Addition
2.568
# of Units
INSULATION
Area
n/a
1
0.480
Construction Tyee
Cavi# ftp Special
Features
Status
FENESTRATION
I
0.37
Sidefins
Exterior Shades
Total Area:
673
Glazin Pe
Orientation
Area ftp
U -Fac
SHGC
Overha
Skylight
3.5
0.480
0.27
none
Skylight
3.5
0.480
0.27
none
Skylight
3.5
0.480
0.27
none
Skylight
3.5
0.480
0.27
none
Skylight
0.5
0.510
0.22
none
Skylight
0.5
0.510
0.22
none
Skylight
0.5
0.510
0.22
none
Skylight
0.5
0.510
0.22
none
HVAC SYSTEMS
Qty. Heating Min. Eff Coolir
HVAC DISTRIBUTION
Location Heating Coolin
WATER HEATING
Qtv. Tvr)e
e; 26.2
New/Altered Average U -Factor:
0.37
Sidefins
Exterior Shades
Status
none
None
New
none
None
New
none
None
New
none
None
New
none
None
New
none
None
New
none
None
New
none
None
New
Min. Eff
Duct Location
Gallons Min. Eff Distribution
7.2 by En M Y -Soft User Number. 5732 i[]_ L01
Thermostat Status
Duct
R -Value Status
Status
12 of 17
2016 Low-Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. *Exceptions may apply.
(Revised 04/2017
Building Envelope Measures:
§ 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfrn/il= or less when tested per
NFRC-400 or ASTM E283 orAAMAIWDMAICSA 101/I.S.2]A440-2011,'
§ 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
110.6-A and 110.6-B for eom liance and must be Caulked and/or weatherstri
§ 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed or weather slri
§ 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal einittance and aged solar reflectance values of the roofing
material must meet the requirements of § 1110.8(l) when the installalion of a cool roof is specified on the CF1 R.
§ 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood-frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter root alteration. Attic access doors must have permanently attached
§ 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placiIig insulation either above or below the roof deck or on top of a drywall ceiling
§ 150.0(b): Loose-fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a Ll-factor of 0.102 or less (R-19 in 2x6 or U-
§ 150.0(c): factor of 0.074 or less). Opaque non-framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed
value of R-13 in a wood framed assembly.'
§ 150.0(d): Raised-floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.'
§ 150.0(0: Slab Edge insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration; and, when installed as pad of a heated slab floor, meet the requirements of § 110.8.
§ 150.0(g)1: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class 11 vapor retarder. This
requirement also applies to controlled ventilation crawls ace for buildings complynng with the exoe tion to § 150.0 d .
§ 150.0(g)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
insulation in all exterior walls, vented attics, and unvented attics with air-permeable insulation.
§ 150.0(q): Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U•faclor of 0.58; or the weighted average Ll-factor of all fenestration must not exceed 0,58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)lA: Closable Doors. Masonry or factory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)l B: Combustion Intake. Masonry or factory-built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible o le and ti ht-fitting damper or combustion air control device.'
§ 150.0(e)lC: Flue Damper. Masonry or factory-built fireplaces must have a flue damper with a readily accessible control'
§ 150,0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are rohibiled.
Space Conditioning, Water Heating, and Plumbing System Measures.
§ 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut-on temperature for compression heating is higher than the cut-on temperature for supplementary heating, and the cut-off temperature for
compression heatin is higher than the cut-off temperature for supplementary heatin
§ 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water healing recirculation loops serving multiple dwelling units must
§ 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
11 0.3c 5.
§ 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr.(2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
§ 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces; household cooking appliances (appli-
ances without an electrical supply vol! a connection with pilot lights that consume less than 150 Btu/hr are exempt): and pool and spa heaters:
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions specified in J 150.012.
WW 2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
d er vent.
§ 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures'
§ 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve.'
§ 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
;ioing for steam and h dronic heating systems or hot waters slems must meet the requirements in TABLE 120.3-A.'
§ 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
caused radalion of the material.
§ 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction
Class I or Class Is vapor retarder. piping located outside the conditioned space must have a
Gas or Propane Systems. Systennis using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a as supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Cor oration SRCC or by a listing agency that is approved by the Executive Director.
Ducts and Fans Measures:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604,0 of the California Mechanical Cods (CIVIC). If a
§ 110.8(d)3; contf actor installs the insulation, the contractor must certifyto the customer, in writing, that the insulation meets this requirement.
)
CMC Compliance. Ail air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
duces. Ducts installed in cavities and support platforms must not be com ressed to cause reductions in the crass -sectional area of the ducts.'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tae is used in combination with mastic and draw bands
§ 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other r uiremenls specified for duct construction.
§ 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dam
§ 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually o rated.dam rs in all openings'to the outside, except combustion intet and outlet air nlnO and elevator shaft vents.
Protection of Insulation. insulation must be protected from damage, including. that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9 wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0 m 11and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through duclwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of 150.0012.
` 2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Fllter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13: supply plenum, The space conditioning system must also demonstrate airflow 2t 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy _< 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced airs stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(0): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation
§ 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following a thermal efficiency
§ 110.4(a): that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.'
§ 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0 Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
§ (p)' rate, i in , filters, and valves.'
Lighting Measures:
§ 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of§ 110.9.'
§ 110.9(e): JAS High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k;, a residential light source must
be certified to the Energy Commission accordLng to Reference Joint Appendix JA8.
§ 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection In all recessed downli ht luminaires in ceilings.
§ 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night fight and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by v ncy sensors.
§ 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0 k
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8.'
§ 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions,
§ 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
4 150.0(k),
§ 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be usea to comply with dimmer requirements if it:
§ 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130_5M; ; and meets all other r uirements in § 150.0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150,0(k) if it meets all of the
§ 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5 ; and all other r uirements in § 150.Q(k)2-
§
50.0 k 2_§ 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
rovides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in 4150.0(k)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference JointAppendix JAB, except luminaires in closets less than 70 square feet and luminaires inhallways.'
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
FMCS,
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either 5 150.0(k)3A or with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0-
§ 150.0(k)3C:
Residentlal Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0 k B or § 150.0(k)3D must comoy with the applicable requirements In §J 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site mustcomply with the applicable requirements In §§ 110.9, 130.0. 130.2, 130.4, 140.7, and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
ower as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential gaLes in §§ 110.9, 130.0, 130.1, 130.4,140.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light full on and off from all desi ned aths of ingress and egres&
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.10 b 1hroug h 110.10 e .
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.*
ui ment.-
Shading.
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)38:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical lane."
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel), and a path2k for routing of Oumbi2q from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.10 c must be pfovided to the occu pant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric'.
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Dr. Robbi D Simons
Date
1/29/2019
System Name
HVAC System
Floor Area
2,568
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 1,533
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation F 0
Supply Fan
Supply Air Ducts1,762
TOTAL SYSTEM LOAD 1
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent i CFM
Sensible
Output per System 42,500
30,530
839 538
20,846
Total Output Btuh 85,000
0
Output Btuh/s ft 33.1
1,762
797
Cooling System
0
0
Output per System 47,500
0
0
0 0
Total Output Btuh 95,000
0
839
0
Total Output (Tons) 7.9
...................�
797
Total Output Btuh/s ft 37.0
Total Output s ft/Ton 324.4
34,055
22,440
Air System
CFM per System
0
HVAC EQUIPMENT SELECTION
Airflow cfm
0
Trane 4WCY5048A1
78,975 1,492
53,089
Airflow cfm/s ft
0.00
Airflow cfm/Ton
0.0
Outside Air %
0-0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
78,975 1,492
Aug 3 PM
53,089
Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions 1
HEATING SYSTEM PSYCHROMETRICS
lAirstrearn Temperatures at Time of Heating
Peak
2a OC
Outside Air
AP -
0 cfm
67 IF
Heating Coil
104 IF
ROOM
68 IF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling
Peak
Outside Air
0 cfm
7F T
14
4
h
Cooling Coil
Ai
56154 °F
46,7% ROOM
75162 7