Loading...
BRES2018-037678-495 CALLE TAMPICO T4ht UVOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Permit Type/Subtype: BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED Owner: Application Number: BRES2018-0376 BR GROUP Property Address: 54765 AVENIDA JUAREZ 54765 AVENIDA JUAREZ APN: 774265031 LA QUINTA, CA 92253 Application Description: SIMONS / 2,568SF SINGLE FAMILY DWELLING Property Zoning: ^ Application Valuation: $168,960.70 I`L•Jjk ?DApplicant: Contractor: CORONEL ENTERPRISES INC APR 2 5 2019 CORONEL ENTERPRISES INC 42760 MADIO STREET 42760 MADIO STREET INDIO, CA 92201 CITY OF LA QUINTA INDIO, CA 92201 DESIGN & DEVELOPMENT DEP,rtRTMENT (760)775-1234 Llc. No.: 727199 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 7 7 99 Date'ntractor: _�,_,A, CZn=:,Q OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: () I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). () I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C, for this reason Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Add Date: 4/25/2019 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of tr for which this permit is issued. ! have and will maintain workers' compensation insurance, as required by Section 700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: BENCHMARK INSURANCE COMPANY _ Policy Number: CST5014903 — I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section of he Labor Code, I shWVVrthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct, I agree to comply with all city and county ordinances and state laws relating to bui g construction, and hereby authorize representatives oftcity enter u the above-mentioned property for inspection purposes. Date: `i -•S -(9 `1 Signature (Applicant or Agent . Application Number: BRES2018-0376 Property Address: 54765 AVENIDA JUAREZ APN: 774265031 Application Description: SIMONS / 2,568SF SINGLE FAMILY DWELLING Property Zoning: Application Valuation: $168,960.70 Applicant: CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO, CA 92201 Owner: BR GROUP 54765 AVENIDAJUAREZ LA QUINTA, CA 92253 Contractor: CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO, CA 92201 (760)775-1234 Llc. No.: 727199 Date: 4/25/2019 --------------------------------------------------------------------------------------------- Detail: 2,568SF DWELLING - [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $7.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $7.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - LIBRARIES 253-0000-43200 0 $344.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - PARKS/REC 251-0000-43200 0 $2,048.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 DESCRIPTION ACCOUNT QTY AMOUNT SERVICES 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT SERVICES PC 101-0000-42600 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT TEMP POWER SERVICE 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT TEMP POWER SERVICE PC 101-0000-42600 0 $18.68 Total Paid for ELECTRICAL: $85.38 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $40.83 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $16.80 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $160.10 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $52.83 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $270.56 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF 101-0000-42408 0 $40.02 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF PC 101-0000-42600 0 $40.02 Total Paid for GRADING: $80.04 DESCRIPTION ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $80.04 DESCRIPTION ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $53.36 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD 101-0000-42402 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD PC 101-0000-42600 0 $5.34 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE 101-0000-42402 0 $80.04 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE PC 101-0000-42600 0 $53.36 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN 101-0000-42402 0 $53.36 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN PC 101-0000-42600 0 $21.36 Total Paid for MECHANICAL: $360.20 DESCRIPTION ACCOUNT CITY AMOUNT MULTI -SPECIES RESIDENTIAL 0-8 UNITS - 2018 UPDATE 101-0000-20310 0 $1,290.00 Total Paid for MULTI -SPECIES RESIDENTIAL: $1,290.00 DESCRIPTION ACCOUNT CITY AMOUNT NEW CONSTRUCTION PERMIT 101-0000-42400 0 $614.54 Total Paid for NEW CONSTRUCTION PERMIT: $614.54 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,268.19 Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,268.19 DESCRIPTION ACCOUNT CITY AMOUNT PLAN CHECK DEPOSIT- RESIDENTIAL 101-0000-42600 1 $750.00 Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $750.00 DESCRIPTION ACCOUNT QTY AMOUNT BACKFLOW DEVICE 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT BACKFLOW DEVICE PC 101-0000-42600 0 $5.34 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $160.08 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $160.08 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $40.02 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT SEPTIC SYSTEM 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT SEPTIC SYSTEM PC 101-0000-42600 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $8.00 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $13.34 Total Paid for PLUMBING FEES. $480.24 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $21.97 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $21.97 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($750.00) DESCRIPTION ACCOUNT QTY AMOUNT SINGLE FAMILY DETACHED 2018 UPDATE 224-0000-20320 0 $750.00 DESCRIPTION ACCOUNT QTY AMOUNT SINGLE FAMILY DETACHED 2018 UPDATE 224-0000-20320 0 $1,560.00 Total Paid for TUMF - RESIDENTIAL: $1,560.00 CERTIFICATE OF COMPLIANCE Nor+gib SC�0 Desert Sands Unified School District } r"� 47950 Dune Palms Road "","'•'111, = I; cuu n1•r e Date: 4/22/2019 La Quinta, CA 92253 r .:- H `0 .; T;',i No.: 19-01309-1 (760)771-8515° Owner: Coronel Enterprises Address: 42760 Madio St City: Indio Type: Single Family Residential Email: Jurisdiction: Indio Tract #: Lot # Street No. Street Name Sq. Feet APN Permit No. 54-765 Avenida Juarez 2568 774-265-031 Comments: At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.79 X 2568 S.F. or $9,732.72 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: CCCaI' iia BanY,Lftr�.f-�.i.:..5.ir.7�c�ris Bank Name/Recipient of Certificate By Scott L. Bailey Superintendent Fee Collected/ Exempted by: Arianne Catano Check No.: 608470 Telephone: 510-918-5020 Funding: Residential Certificate Fees Due: $9,732.72 Original Payment(s) Recd: $0.00 New Payment Rec'd: $9,732.72 Over/Under: $0.00 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. RECORDING REQUESTED BY Lawyers Title - IE WHEN RECORDED MAIL THIS DOCUMENT AND TAX STATEMENTS TO: BR Group, a California Limited Partnership 1330 Neptune Avenue I.eucadia, CA 92024 APN: 774-265-031-3 Escrow No: PDLISS93-LT139-NB Title No: 618690888 rR A ' O 20- O I J` GRANT DEED DOC # 2018-0089589 03/08/2018 04:34 PM Fees: $37.00 Page 1 of 2 Recorded in Official Records County of Riverside Peter Aldana Assessor -County Clerk -Recorder "This document was electronically submitted to the County of Riverside for recording" Receipted by: MARY #420 Space above this line for Recorder's use THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX IS $165.00 ® computed on full value of property conveyed ® City of La Qulnta IM Exempt from fee per GC 27388.1 (a) (2); recorded concurrently in connection with a transfer subject to the Imposition of documentary transfer tax , AND FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Sergio Mejia, Trustee and Mary L. Mejia, Trustee of The Mejia Trust dated February 26, 2003 hereby GRANT(S) to BR Group, a California Limited Partnership the following described real property in the County of Riverside, State of CALIFORNIA.- For ALIFORNIA:For legal description of the real property herein, see Exhibit A attached hereto and made a part hereof. Commonly known as: APN 774-265-031-3 , La Quinta, CA 92253 Dated: Marc}, 2016 The M Ir'ust dated February 26, 2003 APR 10 2019 By: Mary r.�Nejla, A notary public or other officer completing this certificate verifies only the Identity of the Individual who signed the document to which this certificate Is attached, and not the truthfulness, accuracy, or validity of that document. STATE OF CALIFORNIA ) �n � COUNTY OF �/�,(/� i t )SS. On 1 TMP before me, Notary Public, personally appearedL1 who proved to me n the basis of satisfactory evidence to be the person(s) whose name(s) Is/are subscribed to the within Instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capaclty(les), and that by hls/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the Instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph Is true and correct. WITNESS my hand and official seal. Signature _& J�4 A '9— mail -fvl al oi(reS 5. Gl1ERPA Notary Public . California Riverside County a Z ComMfg SIort # 2:6$91 1 a 4 COMM. Expires NOY 3, 2020 4 L0 le—o- Exhibit A THE LAND REFERRED TO HEREIN IS SITUATED IN THE COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AND IS DESCRIBED AS FOLLOWS: LOT 1 AND THE NORTH 1/2 OF LOT 2, BLOCK 275, OF SANTA CARMELITA AT VALE LA QUINTA, UNIT NO. 25, IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS SHOWN ON FILE IN BOOK 19, PAGES 50 AND 51, OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. ASSESSOR'S PARCEL NUMBER: 774-265-031-3 Building Permit Number: EOCSZQI - 0 370 Project Description: SFR Exempt: r_1 (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Plan Submittal Date I 4/23/2019 Job Site Address I 54-765 Avenida Juarez owners Neme Dr. Robi Simons Number, Street, or PO Box 54-765 Avenida Juarez City, State, Postal Code La Quinta, Ca. 92253 Owners Phone Number c/o 760-775-1234 Owners E -Mail Add Project Managers Project Manager's Phone N Project Managers E-mail Ai Builder/ Contractor Number, Street or PO Box City, State, Postal Code Project Square Footage Ish Coronel 760-775-1234 co ro n e lvffice0corone le nt,co m Coronel Enterprises 42760 Madio St Indio, Ca. 92201 Approx. 2,568 sq ft RECEIVED APR 2 5 2019 CITY OF LA QUINTA DESIGN AND DEVELOPMENT DEPARTMENT City Approval By Renado Gouldlock-DEC/Buntec Wast i��P,&awo�--�-) Date of City Approval Is To Be Discarded: Product Trash Asphalt Brick/Block Cardboard Commingled Concrete Drywall Donated / Reuse* `Describe Items Tons 10.25 Not recyclable 0.00 Recyclable 0.00 Recyclable 0.00 Recyclable 0.00 Recyclable 11.25 Recyclable 1.25 Recyclable 0.00 Recyclable Totals: Recycle Trash 1 20.01 F 10.3 Product Masonry (broken) Plaster Scrap Metal Tile (floor) Tile (roof) Wood Landscape Debris Tons 0.00 Recyclable 3.00 Recyclable 0,00 Recyclable 0.15 Recyclable 0.35 Recyclable 4.00 Recyclable 0,00 Recyclable Projected Diversion: 66.12% I understand it Is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste Is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the props owners) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agsnl of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property oner(s) and the owner retains legal responsibility for ensuring that the provisions of the QMP,are adhered to. The•property o ner(s)'and general contractor shall be kept informed of the diversion progress through bl-mo lhly reports. If elf -hauling, all refused material from this project site must be taken to an approved recycler or transfer Manager! S rintendant Dale kro5p-241 F$ OW 0 31 to BUILDING ENERGY ANALYSIS REPORT CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE Z Z g'y RECE-NeD PROJECT: Dr. Robbi D Simons 34765 Avenida Juarez La Quinta, Ca 92253 Project Designer: Santiago Lopez Ocampo - Drafting & Design P.O. Box 1018 La Quinta, Ca 92247 760.485.8927 Report Prepared by: SLO Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, Ca 92247 760.485.8927 SHgbs AI/ENlUA 00JOuAkE2 Job Number: LQ 110518 Date: FEB 0 6 2019 1/29/2019 coon; The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software - www.energysoft.com. GI 42 TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form .CF -1 R -PRF -01-E Certificate of Compliance 3 Form RMS -1 Residential Measures Summary 11 Form MF -1 R Mandatory Measures Summary 13 j HVAC System Heating and Cooling Loads Summary 17 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Dr. Robbi D Simons Calculation Description: Title 24 Analysis Calculation Date/Time: 09:06, Tue, Jan 29, 2019 Input File Name: Dr. Simons - 54765 Avenida Juarez - Rev010919.ribd16x CFI R -PRF -01 Page 1 of 8 COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 0.64 1.95 -1.31 -204.7% Space Cooling 80.09 71.28 8.81 11.0% IAQ Ventilation 1.00 1.00 0.00 0.0% Water Heating 5.06 4.36 0.70 13.8% Photovoltaic Offset 0.00 0.00 — Compliance Energy Total 86.79 78.59 8.20 9.4% Registration Number: 218-Po10300033C-000-000-0000000-0000 Registration Date/Time: 2019-01-29 11:43:47 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-29 09:08:23 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Dr. Robbi D Simons Calculation Date/Time: 09:06, Tue, Jan 29, 2019 Calculation Description: Title 24 Analysis Input File Name: Dr Simons - 54765 Avenida Juarez - Rev010919 ribdl6x CF1 R -PRF -01 Page 2 of 8 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 53.2 49.5 0.0 49.5 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on-site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Insulation below roof deck • Exposed slab floor in conditioned zone HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • -- None -- Registration Number: 218-Po10300033C-000-000-0000000-0000 Registration Date/Time: 2019-01-29 11:43:47 HERS Provider: CaiCERTs inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-01162019-1149 Report Generated at: 2019-01-29 09:08:23 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Dr Robbi D Simons Calculation Date/Time: 09:06, Tue, Jan 29, 2019 Calculation Description: Title 24 Analysis Input File Name: Dr. Simons - 54765 Avenida Juarez - Rev010919.ribd16x CFI R -PRF -01 Page 3 of 8 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Dr- Robbi D Simons 2568 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Whole House Conditioned HVAC System1 2568 11 DHW Sys 1 n/a OPAQUE SURFACES 01 02 03 04 05 06 07 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ftZ) Window & Door Area (ft) Tilt (deg) East Whole House R-21 Wall + 1 EPS 90 Front 210 95 90 South Whole House R-21 Wall + 1 EPS 180 Left 507 79.17 90 West Whole House R-21 Wall + 1 EPS 270 Back 490.41 134 90 North Whole House R-21 Wall + 1 EPS 0 Right 770 348.5 90 Interior Surface Whole House R-21 Wall n/a n/a 587.58 0 n/a Roof 2 Whole House R-38 HP Attic Option B w/ n/a n/a 2551.76 n/a n/a OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 Name Zone Type Orientation Area (ft) Skylight Area (ft2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Roof Whole House R-38 HP Attic Option B w/1 Left 1634 16.24 0.2 0.6 0.89 Yes ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Whole House Attic RoofWhole House Unventilated 0.2 06 0.89 No Yes Registration Number: 218-P010300033C-000-000-0000000-0000 Registration Date/Time: 2019-01-29 11:43:47 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-29 09:08:23 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Dr. Robbi D Simons Calculation Date/Time: 09:06, Tue, Jan 29, 2019 Calculation Description: Title 24 Analysis Input File Name: Dr. Simons - 54765 Avenida Juarez - Rev010919.ribd16x CF1 R -PRF -01 Page 4 of 8 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height Width (ft) (ft) Multiplier Area (ft) U -factor SHGC Exterior Shading 10080 XXO MasterBed Window East (Front -90) 1 80.0 0.42 0.23 Insect Screen (default) 10016 FIX MasterBed Window East (Front -90) - - 1 15.0 0.26 0.23 Insect Screen (default) 3040 SH Laundry Window South (Left -180) 1 12.0 0.27 0.25 Insect Screen (default) 3016 FIX Laundry Window South (Left -180) 1 4.5 0.26 0.23 Insect Screen (default) 5040 XO Bed 2 Window South (Left -180) 1 20.0 0.27 0.25 Insect Screen (default) 5016 FIX Bed2 Window South (Left -180) -- 1 7.5 0.26 0.23 Insect Screen (default) 2040 SH Bath2 Window South (Left -180) 1 8.0 0.27 0.25 Insect Screen (default) 2016 FIX Bath2 Window South (Left -180) 1 3.0 0.26 0.23 Insect Screen (default) 2854 Glass Block Window South (Left -180) 1 14.2 0.51 0.66 Insect Screen (default) 5020 FIX Bed3 Window South (Left -180) 1 10.0 0.26 0.23 Insect Screen (default) 6080 SGD Bed3 Window West (Back -270) 1 48.0 0.41 0.31 Insect Screen (default) 6016 FIX Bed2 Window West (Back -270) - -- 1 9.0 0.26 0.23 Insect Screen (default) 3040 SH Office Window West (Back -270) - -- 1 12.0 0.40 0.24 Insect Screen (default) 3016 FIX Office Window West (Back -270) - - 1 45 1 0.26 0.23 Insect Screen (default) 3080 FrDr GreatRoom Window West (Back -270) - 1 24.0 0.29 0.21 Insect Screen (default) 3016 FIX GreatRoom Window West (Back -270) ---- 1 4.5 0.26 0.23 Insect Screen (default) 4040 FIX GreatRoom Window West (Back -270) -•-- ---- 1 16.0 0.26 0.23 Insect Screen (default) 4040 FIX GreatRoom 2 Window West (Back -270) --- --- 1 16.0 0.26 0.23 Insect Screen (default) 16080 XXXO GreatRoom Window North (Right -0) - - 1 128.0 0.42 0.23 Insect Screen (default) 16016 FIX Bed2 Window North (Right -0) ---- •••. 1 24.0 0.26 0.23 Insect Screen (default) 3080 FrDr GreatRoom 2 Window North (Right -0) ---- ---- 1 24.0 0.29 0.21 Insect Screen (default) 3016 FIX GreatRoom 2 Window North (Right -0) ---- •••• 1 4.5 0.26 0.23 Insect Screen (default) 10050 OXXO Kitchen Window North (Right -0) 1 50.0 0.40 0-24 Insect Screen (default) 10016 FIX Kitchen Window North (Right -0) ---- --- 1 15.0 0.26 0.23 Insect Screen (default) 4020 FIX MBath Window North (Right -0) ---- -- 1 8.0 0.26 0-23 Insect Screen (default) 10080 XXO MasterBed 2 Window North (Right -0) ---- •-•• 1 80-0 0.42 0-23 Insect Screen (default) 10016 FIX MasterBed 2 Window North (Right -0) ---- 1 15.0 0.26 1 0.23 Insect Screen (default) Velux FCM 2222 MBath Skylight Roof (Left -180) 1 3.5 0.48 0.27 Velux FCM 2222 MBath 2 Skylight Roof (Left -180) 1 3.5 0.48 0-27 Registration Number: 218-P010300033C-000-000-0000000-0000 Registration DateRme: 2019-01-29 11:43:47 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-29 09:08:23 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Dr Robbi D Simons Calculation Date/Time: 09:06, Tue, Jan 29, 2019 Calculation Description: Title 24 Analysis Input File Name: Dr. Simons - 54765 Avenida Juarez - Rev010919.ribd16x CF1 R -PRF -01 Page 5 of 8 Velux FCM 2222 Hallway Skylight Roof (Left -180) 1 3.5 0.48 0.27 Velux FCM 2222 Hallway 2 Skylight Roof (Left -180) 1 3.5 0.48 0.27 10 Solatube MCloset Skylight Roof (Left -180) 1 .5 0.51 022 10 Solatube Pantry Skylight Roof (Left -180) 1 .5 0.51 022 10 Solatube Bath2 Skylight Roof (Left -180) 1 .5 0.51 0.22 10 Solatube Powder. Skylight Roof (Left -180) 1 5 1 0.51 0.22 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Zone Area (ft) Perimeter (ft) Edge Insul. R -value & Depth Total Cavity Winter Design Slab -on -Grade Construction Name Surface Type Construction Type Framing R -value U -factor Assembly Layers Whole House 1000 0.1 None 1 No • Around Roof Joists: R-0.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofWhole House Attic Roofs Wood Framed Ceiling in. O.C. R 13 0 078 Roofing: Light Roof (Asphalt Shingle) Inside Finish: Gypsum Board Cavity/Frame: R-21 /2x6 Sheathing/ Insulation: R4.2 Sheathing R-21 Wall + 1 EPS Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C- R 21 0.050 Exterior Finish: 3 Coat Stucco Inside Finish: Gypsum Board Cavity/ Frame: R-21 / 2x6 R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. 0 C R 21 0.064 Other Side Finish: Gypsum Board Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 HP Attic Option B w/ attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Sheathing /Insulation: R13 Sheathing Cavity / Frame: R-38 / 2x4 • Roof Deck: Wood Siding/sheathing/decking R-38 HP Attic Option B w/1 Cathedral Ceilings Wood Framed Ceiling 2x4 @ 24 in. O.0 R 38 0.021 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated Slab -on -Grade Whole House 1568 0.1 None 0 No Slab -on -Grade 2 Whole House 1000 0.1 None 1 No Registration Number: 218-P010300033C-000-000-0000000-0000 Registration DateFl-ime: 2019-01-29 11:43:47 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-29 09:08:23 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Dr. Robbi D Simons Calculation Date/Time: 09:06, Tue, Jan 29, 2019 Calculation Description: Title 24 Analysis Input File Name: Dr. Simons - 54765 Avenida Juarez - Rev010919.ribd16x BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required n/a CF1 R -PRF -01 Page 6 of 8 WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 (1) 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER I EER Input Rating / Tank Standby 8.4 42500 29750 15 12 Heater Single Speed Heat Pump System 1 -hers -cool Tank Uniform Energy Pilot / Insulation Loss / First Hour NEEA Heat Pump Tank Location Element Number Volume Factor / Energy Thermal R -value Recovery Rating / Brand / Model / or Ambient Name Type Tank Type of Units (gal) Factor/ Efficiency Efficiency (IntlExt) Eff Flow Rate Other Condition DHW Heater 1 Gas Small 1 0 0.95 EF <= 200 kBtu/hr R -0/R-0 0 n/a n/a n/a Instantaneous SPACE CONDITIONING SYSTEMS 01 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC Systeml Heat Pump Heating and Heat Pump System 1 Heat Pump System 1 HVAC Fan 1 Air Distribution System 1 Cooling System HVAC - HEAT PUMPS 01 02 03 04 05 ' 06 07 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER I EER Heat Pump System 1 SplitHeatPump 2 8.4 42500 29750 15 12 Not Zonal Single Speed Heat Pump System 1 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Heat Pump System 1 -hers -cool Required 350 Required Required Required Registration Number: 218-P010300033C-000-000-0000000-0000 Registration Date/Time: 2019-01-29 11:43:47 HERS Provider: CaiCERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-01-29 09:08:23 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Dr. Robbi D Simons Calculation Date/Time: 09:06, Tue, Jan 29, 2019 Calculation Description: Title 24 Analysis Input File Name: Dr. Simons - 54765 Avenida Juarez - Rev010919.ribd16x CF1 R -PRF -01 Page 7 of 8 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 1 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1 -hers -dist Required 50 Not Required Not Required Not Required Not Required Required HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 56 025 Default 0 Required Registration Number: 218-Po10300033C-000-000-0000000-0000 Registration DateRme: 2019-01-29 11:43:47 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-01-29 09:08:23 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Dr Robbi D Simons Calculation Description: Title 24 Analysis DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Company: Santiago Lopez-Ocampo Address: P.O. Box 1018 City/State/Zip: La Quinta, CA 92247 RESPONSIBLE PERSON'S DECLARATION STATEMENT Calculation DatefTime: 09:06, Tue, Jan 29, 2019 Input File Name: Dr. Simons - 54765 Avenida Juarez - Rev010919 ribd16x Documentation Author Sior,a;wr Signature Date: 2019-01-29 11:43:47 CEA/HERS Certification Identification (If applicable): NA Phone: 760-485-8927 CFI R -PRF -01 Page 8 of 8 I certify the following under penalty of perjury, under the laws of the State of California: I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature Santiaoo Looez-Ocarnno Company: Santiago Lopez-Ocampo Address: P.O. Box 1018 City/State/Zip: La Quinta, CA 92247 Date Signed: 2019-01-29 11:43:47 License: NA Phone: 760-485-8927 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 218-P010300033C-000-000-0000000-0000 Registration DateRme: 2019-01-2911:43:47 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Easy to Verify at CaICERTS.com HERS Provider: CaICERTS inc. Report Generated at: 2019-01-29 09:08:23 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Dr. Robbi D Simons Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/29/2019 Project Address 54765 Avenida Juarez La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area Addition 2,568 n/a # of Units 1 INSULATION Construction Type Cavity Area ( e) Special Features Status Slab Unheated Slab -on -Grade - no insulation 2,568 Perim = 0' New Wall Wood Framed R 21 1,321 Add=R-4.2 New Demising Wood Framed R 21 588 New Roof Wood Framed Attic R 38 2,552 Add=R-13.0 Cool Roof New FENESTRATION Orientation Area(ft) I Total Area: 673 Glazing Percenla e: 26-2 U -Fac SHGC Overhang Sidefins New/Altered Avera ge U -Factor: 0-37 Exterior Shades Status Front (E) 80.0 0-420 0.23 none none Bug Screen New Front (E) 15.0 0.260 0.23 none none Bug Screen New Left (S) 20.0 0.270 0.25 none none Bug Screen New Left (S) 25.0 0.260 0.23 none none Bug Screen New Left (S) 20.0 0.270 0.25 none none Bug Screen New Left (S) 14.2 0.510 0.66 none none Bug Screen New Rear (W) 48.0 0.410 0.31 none none Bug Screen New Rear (W) 50.0 0.260 0.23 none none Bug Screen New Rear (W 12.0 0.400 0.24 none none Bug Screen New Rear (W) 24.0 0.290 0.21 none none Bug Screen New Right (N) 208.0 0.420 0.23 none none Bug Screen New Right (N) 66.5 0.260 0.23 none none Bug Screen New Right (N) 24.0 0.290 0.21 none none Bug Screen New Right (N) 50.0 0.400 0.24 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Split Heat Pump 8.40 HSPF Split Heat Pump 15.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status HVAC System Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type .......... _... - Gallons Min. Eff Distribution Status 1 Small Instantaneous Gas 0 0.95 Standard New Ener Pro 7.2 by Enea7.vSoft User Number: 5732 ID: LQ110518 Pae 11 of 17 RESIDENTIAL MEASURES SUMMARY I 0.37 Sidefins Project Name Dr. Robbi D Simons Building Type m Single Family ❑ Addition Alone RMS -1 Date Project Address ❑ Multi Family ❑Existing+ Addition/Alteration 1/29/2019 54765 Avenida Juarez La Quints California Energy Climate Zone CA Climafe Zone 15 Total Cond. Floor Area Addition 2.568 # of Units INSULATION Area n/a 1 0.480 Construction Tyee Cavi# ftp Special Features Status FENESTRATION I 0.37 Sidefins Exterior Shades Total Area: 673 Glazin Pe Orientation Area ftp U -Fac SHGC Overha Skylight 3.5 0.480 0.27 none Skylight 3.5 0.480 0.27 none Skylight 3.5 0.480 0.27 none Skylight 3.5 0.480 0.27 none Skylight 0.5 0.510 0.22 none Skylight 0.5 0.510 0.22 none Skylight 0.5 0.510 0.22 none Skylight 0.5 0.510 0.22 none HVAC SYSTEMS Qty. Heating Min. Eff Coolir HVAC DISTRIBUTION Location Heating Coolin WATER HEATING Qtv. Tvr)e e; 26.2 New/Altered Average U -Factor: 0.37 Sidefins Exterior Shades Status none None New none None New none None New none None New none None New none None New none None New none None New Min. Eff Duct Location Gallons Min. Eff Distribution 7.2 by En M Y -Soft User Number. 5732 i[]_ L01 Thermostat Status Duct R -Value Status Status 12 of 17 2016 Low-Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. *Exceptions may apply. (Revised 04/2017 Building Envelope Measures: § 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfrn/il= or less when tested per NFRC-400 or ASTM E283 orAAMAIWDMAICSA 101/I.S.2]A440-2011,' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-B for eom liance and must be Caulked and/or weatherstri § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed or weather slri § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal einittance and aged solar reflectance values of the roofing material must meet the requirements of § 1110.8(l) when the installalion of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood-frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter root alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placiIig insulation either above or below the roof deck or on top of a drywall ceiling § 150.0(b): Loose-fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a Ll-factor of 0.102 or less (R-19 in 2x6 or U- § 150.0(c): factor of 0.074 or less). Opaque non-framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.' § 150.0(d): Raised-floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.' § 150.0(0: Slab Edge insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as pad of a heated slab floor, meet the requirements of § 110.8. § 150.0(g)1: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class 11 vapor retarder. This requirement also applies to controlled ventilation crawls ace for buildings complynng with the exoe tion to § 150.0 d . § 150.0(g)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air-permeable insulation. § 150.0(q): Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U•faclor of 0.58; or the weighted average Ll-factor of all fenestration must not exceed 0,58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)lA: Closable Doors. Masonry or factory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory-built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible o le and ti ht-fitting damper or combustion air control device.' § 150.0(e)lC: Flue Damper. Masonry or factory-built fireplaces must have a flue damper with a readily accessible control' § 150,0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are rohibiled. Space Conditioning, Water Heating, and Plumbing System Measures. § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut-on temperature for compression heating is higher than the cut-on temperature for supplementary heating, and the cut-off temperature for compression heatin is higher than the cut-off temperature for supplementary heatin § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water healing recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 11 0.3c 5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr.(2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces; household cooking appliances (appli- ances without an electrical supply vol! a connection with pilot lights that consume less than 150 Btu/hr are exempt): and pool and spa heaters: Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions specified in J 150.012. WW 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any d er vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures' § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution ;ioing for steam and h dronic heating systems or hot waters slems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can caused radalion of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction Class I or Class Is vapor retarder. piping located outside the conditioned space must have a Gas or Propane Systems. Systennis using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a as supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Cor oration SRCC or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604,0 of the California Mechanical Cods (CIVIC). If a § 110.8(d)3; contf actor installs the insulation, the contractor must certifyto the customer, in writing, that the insulation meets this requirement. ) CMC Compliance. Ail air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain duces. Ducts installed in cavities and support platforms must not be com ressed to cause reductions in the crass -sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other r uiremenls specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dam § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually o rated.dam rs in all openings'to the outside, except combustion intet and outlet air nlnO and elevator shaft vents. Protection of Insulation. insulation must be protected from damage, including. that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9 wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m 11and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through duclwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of 150.0012. ` 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Fllter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum, The space conditioning system must also demonstrate airflow 2t 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy _< 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(0): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.' § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow § (p)' rate, i in , filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of§ 110.9.' § 110.9(e): JAS High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k;, a residential light source must be certified to the Energy Commission accordLng to Reference Joint Appendix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection In all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night fight and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by v ncy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0 k Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions, § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 4 150.0(k), § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be usea to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130_5M; ; and meets all other r uirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150,0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 ; and all other r uirements in § 150.Q(k)2- § 50.0 k 2_§ 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it rovides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in 4150.0(k)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference JointAppendix JAB, except luminaires in closets less than 70 square feet and luminaires inhallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or FMCS, Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either 5 150.0(k)3A or with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0- § 150.0(k)3C: Residentlal Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k B or § 150.0(k)3D must comoy with the applicable requirements In §J 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site mustcomply with the applicable requirements In §§ 110.9, 130.0. 130.2, 130.4, 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of ower as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential gaLes in §§ 110.9, 130.0, 130.1, 130.4,140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light full on and off from all desi ned aths of ingress and egres& Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.10 b 1hroug h 110.10 e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.* ui ment.- Shading. Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)38: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane." § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel), and a path2k for routing of Oumbi2q from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 110.10 c must be pfovided to the occu pant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric'. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Dr. Robbi D Simons Date 1/29/2019 System Name HVAC System Floor Area 2,568 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 1,533 Return Vented Lighting Return Air Ducts Return Fan Ventilation F 0 Supply Fan Supply Air Ducts1,762 TOTAL SYSTEM LOAD 1 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent i CFM Sensible Output per System 42,500 30,530 839 538 20,846 Total Output Btuh 85,000 0 Output Btuh/s ft 33.1 1,762 797 Cooling System 0 0 Output per System 47,500 0 0 0 0 Total Output Btuh 95,000 0 839 0 Total Output (Tons) 7.9 ...................� 797 Total Output Btuh/s ft 37.0 Total Output s ft/Ton 324.4 34,055 22,440 Air System CFM per System 0 HVAC EQUIPMENT SELECTION Airflow cfm 0 Trane 4WCY5048A1 78,975 1,492 53,089 Airflow cfm/s ft 0.00 Airflow cfm/Ton 0.0 Outside Air % 0-0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 78,975 1,492 Aug 3 PM 53,089 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions 1 HEATING SYSTEM PSYCHROMETRICS lAirstrearn Temperatures at Time of Heating Peak 2a OC Outside Air AP - 0 cfm 67 IF Heating Coil 104 IF ROOM 68 IF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak Outside Air 0 cfm 7F T 14 4 h Cooling Coil Ai 56154 °F 46,7% ROOM 75162 7