Loading...
BRES2018-0411T4'!t D+tU VOICE (760) 777-7125 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 4/16/2019 Permit Type/Subtype: BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED Owner: Application Number: BRES2018-0411 GT LLC. Property Address: 77234 CASA DEL SOL 4776 WEST MILL RIVER COURT APN: 773360002 COEUR D'ALENE, ID 83814 Application Description: GERVAIS / 3353SF DWELLING LOT 2 [VB/RES-3/CLASS A-FR/13D Property Zoning: Application Valuation: $234,866.20 Applicant:Contractor: n CORONEL ENTERPRISES INC V CORONEL ENTERPRISES INC 42760 MADIO STREET 42760 MADIO STREET INDIO, CA 92201 APR 16 2019 INDIO, CA 92201 CITY OF LA QUINTA (760)775-1234 DESIGN & DEVELOPMENT DEPARTMENT LIc. No.: 727199 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B / `I License No.: Dat@: 1 — 1v 0 Contractor: —L—L OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herselfthrough his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of t fog forwhich this permit is issued. r I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: BENCHMARK INSURANCE COMP NA Y Policy Number: CST5014903 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Sect 3700Iof the Labor Code, I a orthwith comply with those provisions. 1\ 11 r Dim Lt- IC -1 WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives ofcity LL enterE:r mentioned property for inspection purposes. Date: —� �— J_(_ (Applicant or Agent)r Date: 4/16/2019 Application Number: BRES2018-0411 Owner: Property Address: 77234 CASA DEL SOL GT LLC. APN: 773360002 4776 WEST MILL RIVER COURT Application Description: GERVAIS / 3353SF DWELLING LOT 2 [VB/RES-3/CLASS A-FR/13D COEUR D'ALENE, ID 83814 Property Zoning: Application Valuation: $234,866.20 Applicant: Contractor: CORONEL ENTERPRISES INC CORONEL ENTERPRISES INC 42760 MADIO STREET 42760 MADIO STREET INDIO, CA 92201 INDIO, CA 92201 (760)775-1234 } ? Llc. No.: 727199 ----------------------------------i-.-------------------------------------------------------- Detail: 3353 SF DWELLING - LOT 2 [VB/RES-3/CLASS A-FR)13D) THIS PERMIT. DOESjN;QT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH, 2016 CALIFORNIA BUILDING CODES. Total Paid for ART IN PUBLIC PLACES - AIPP: $0.00 DESCRIPTION ACCOUNT QTY FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT 0 101-0000-42600 $942.00 ($87.16) DESCRIPTION ACCOUNT QTY AMOUNT ART IN PUBLIC PLACES - RESIDENTIAL 270-0000-43201 0 $87.16 Total Paid for ART IN PUBLIC PLACES - AIPP: $0.00 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $10.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $10.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - LIBRARIES 253-0000-43200 0 $344.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - PARKS/REC 251-0000-43200 0 $2,048.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $54.44 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $22.40 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $160.10 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $52.83 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $289.77 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT>7KSF 101-0000-42408 0 $40.02 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF PC 101-0000-42600 0 $200.12 Total Paid for GRADING: $240.14 DESCRIPTION ACCOUNT I QTY I AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $120.06 DESCRIPTION ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $80.04 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD 101-0000-42402 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD PC 1 101-0000-42600 0 $5.34 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE 101-0000-42402 0 $120.06 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE PC 101-0000-42600 0 $80.04 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN 101-0000-42402 0 $80.04 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN PC 101-0000-42600 0 $32.04 Total Paid for MECHANICAL: $530.96 DESCRIPTION ACCOUNT CITY AMOUNT MULTI -SPECIES RESIDENTIAL 0-8 UNITS - 2018 UPDATE 101-0000-20310 0 $1,290.00 Total Paid for MULTI -SPECIES RESIDENTIAL: $1,290.00 DESCRIPTION ACCOUNT CITY AMOUNT NEW CONSTRUCTION PERMIT 101-0000-42400 0 $663.69 Total Paid for NEW CONSTRUCTION PERMIT: $663.69 DESCRIPTION ACCOUNT CITY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,410.53 Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,410.53 DESCRIPTION ACCOUNT CITY AMOUNT PLAN CHECK DEPOSIT- RESIDENTIAL 101-0000-42600 1 $750.00 Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $750.00 DESCRIPTION ACCOUNT CITY AMOUNT BACKFLOW DEVICE 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT BACKFLOW DEVICE PC 101-0000-42600 0 $5.34 DESCRIPTION ACCOUNT CITY AMOUNT BUILDING SEWER 101-0000-42401 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT BUILDING SEWER PC 101-0000-42600 0 $18.68 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $240.12 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $240.12 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $40.02 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT ROOF DRAIN 101-0000-42401 0 $213.44 DESCRIPTION ACCOUNT CITY AMOUNT ROOF DRAIN PC 101-0000-42600 0 $213.44 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $8.00 Total Paid for PLUMBING FEES: $1,059.20 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $30.53 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $30.53 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($662.84) DESCRIPTION ACCOUNT CITY AMOUNT SINGLE FAMILY DETACHED 2018 UPDATE 224-0000-20320 0 $1,647.16 DESCRIPTION ACCOUNT CITY AMOUNT SINGLE FAMILY DETACHED 2018 UPDATE 224-0000-20320 0 $662.84 Total Paid for TUMF - RESIDENTIAL: $1,647.16 Cipy of La Quire °I_i!die;5 Sa`ery Divisior P.O. Eox 1 Soo P rrr 78-495 C l!� Tampico La Wcj, CA 92256 '0411 Building Permit Application and Tracking Sheet �rojecr�ddress: ��� 'S Coos �lct on Type: v OccttDancr: Own�r's?va[oe �]re. . �rCC�Zcdv._c Proje- ryoz cir_le one;: rie Ikdd'u ad*=r R=p it i cmc iaine of Contact F_rson: Sq. Fs.: aj S3 m Stories: \ T [mils: 1 Lal escription: a ►�r C � eD Ciry,ST, Zip: �.� �1 Cantr3_t�;' C -1 ,A A L� Tel. pone: 71. 7- , �. �CA, ._0.❑T;�It:!:E;tv�t Trtlstlra r: Address: a� ��� <� Project Desc prion: Pla o Scts.. Cit'ST. Zio �I S Teiepnorn!:'A a 77 j—�11-f `SSW. uCfll:r3: {:...[�::_'... .� . '. : ` ^. ....---i"�..�_._.._.T�.. Srar= r ic_ _:-70--7 Cicv Lic. �. Truss: Caic; r .. �i!isii C surcct:.i �r-s.�b 4 cli.. Eri=.. Desi�er: � c13�� t 1-5 Trtl[.3A CzL_�. i. Plar[,i.R!c'�c . up rr Address: l Q j: ijbMic-td Cir:. ST. Ziaw��\� �.�iC ridOI. C�-'i. •I' �'��:i � r1� ': 'i�C-4'rt�l'CJ... ['ri';I Y.: fI'i �13�12t 7 ....... . •::. �.. �•......... ..:.:i '--:i.]:�? ... ..: � Coos �lct on Type: v OccttDancr: Scare Li=- _. Proje- ryoz cir_le one;: rie Ikdd'u ad*=r R=p it i cmc iaine of Contact F_rson: Sq. Fs.: aj S3 m Stories: \ T [mils: 1 Tele none=orCoarscrPerson:7Lp -S% csamatedValueofProjec: �. �CA, ._0.❑T;�It:!:E;tv�t Trtlstlra r: Pla o Scts.. t :tik sii'buurcc3 E'.l[u'..h . `SSW. uCfll:r3: {:...[�::_'... .� . '. : ` ^. ....---i"�..�_._.._.T�.. T [Y[C Svtli: C:t ii Y.'to-r.rn erz stinxjs I� a ch6c-D.C'r3V . Truss: Caic; r .. �i!isii C surcct:.i �r-s.�b ff iYian=.hbck$iEftcr:.;:>:=:"":. . Trtl[.3A CzL_�. i. Plar[,i.R!c'�c . up rr - ! Canstrrc�rior{;:; .::._.,..-.:;.'„..,3..... j: ijbMic-td j�t��� R ar �.�iC ridOI. C�-'i. •I' �'��:i � r1� ': 'i�C-4'rt�l'CJ... ['ri';I Y.: fI'i �13�12t ....:..::,.:. � :: �,rCC_rT'l l;.tr:� �:. .. .. .=-�: :": �': .::: .... .. •.. ....... . •::. �.. �•......... ..:.:i '--:i.]:�? ... ..: it :.: .... ..: ::..I; . �g Q� A' oarr'aCrar:Ip�s- - Y:: c'.� rti Ila�tc'' ... .. � n o. Ci. $usia ;.� .. ; �. '>: ::..:.: t:ci�liis�::: >i'>'•>:..;.: . r. . p]aA¢ru„ .t.(rnrn ar .,. ...: �.�.:� r:• .'�;:.::S. .. ..... :s ...::: .....:., ...... .. rcb. ti4.ks.A r_ .. .......... Pp. _ .. h 1 ]Y4 V.Yr�:'':: ,4$L rH [7 Rf'pK1i >3S TG6Il j,i.`1 tt.5pcctfoit Date: 4/16/2019 No.: 19-01302-1 Owner: Greg & Terri Gervais Address: 77-234 Casa Del Sol City: La Quinta Type: Single Family Residential Lot # Street No. 77-234 Comments: CERTIFICATE OF COMPLIANCE ���t�ro s Desert Sands Unified School District ""A �''�f•, �o 47950 Dune Palms Road Q La Quinta, CA 92253 w (760)771-8515 Email: Jurisdiction: La Quinta Tract #: Street Name Sq. Feet APN Permit No. Casa Del Sol 3353 773-360-002 At the present time, the Desert Sands Unified School District does not collect fees on garages carports, covered pathos/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.79 X 3353 S.F. or $12,707.87 have ber-:n paid for the property listed alcove and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: CC__Rab4 an Jury Rosa a� Bank Name/Recipient of Certificate By Scott L. Bailey Superintendent Check No.: 7015148 Telephone: 760-775-1234 Funding: Residential Certificate Fees Due: $12,707.87 Original Payment(s) Rec'd: $0.00 New Payment Rec'd: $12,707.87 Over/Under: $0.00 NOTICE: pursuant to Government Code Section 660201dj(1), this will serve to notify you that the 30 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the buliding or installation permit for this project is issued, or from the date on which those amounts are paid to the Districtfs) or to another public �ntitau hori ct them on the District('s) behalf, whichever is earlier. Notice to Building Department: T�fm Y IF IMPRINTED WITH EMBOSSED SEAL. APR 16 2019 CITY OF LA QUINTA COMMUNilY DEVELOPMENT RcCORDING REQUESTED BY: Lawyers Title AND WHEN RECORDED MAIL TO: GT, LLC 4773 W. Mill River Court Coeur d'Alene ID 83814 Order No.: 617692999 Escrow No.: F52237 A.P.N.: 773-360.002-4 TRA: 020-143 :: �10 CE-RTfFY TH.�T irllS }S A Tr L, �i.:IR fi5R571t5CROW. INC. SPACE ABOVE THIS LINE IS FOR F THE UNDERSIGNED GRANTOR(S) DECLARE(S) GRANT DEED DOCUMENTARY TRANSFER TAX IS $ 247.50 [ X ] computed on full value of property conveyed, or [ ] computed on full value less value of liens or encumbrances remaining at time of sale, ] unincorporated area [ X ] City of La Quinta FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Robert James, An Unmarried Man hereby GRANT(S) to GT- LLC, an Idaho Limited Liability Company the following described real property in the County of Riverside, State of California See Exhibit "A" attached hereto and made a part hereof Commonly known as: Vacant Land (APN: 773-360-002-41), La Quinta, CA 92253 Dated: May 12, 2017 A notary public or other officer complet=andnot verifies only the identity of the individua document to which this certificate Is atttruthfulness, accuracy, or validity of tha STATE OF GA4FGRfM W AI COUNTY OF , �,. } SS. On /,-( /"? .Z `' l _7Z before me, f/-' r ---s' , a notary public, personally appeared �J +•rim— " who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the perscn(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is trua7and correct ^f] WITNESS my hand and0fffcjal,seal. Signature.._._ - Robert James S USE RECEIVED APR 16 204419 IioOANMli N fl , OF—Ve •iNimEwr rib$• �' � i d0N�' L �t (This area for official notary seal) / MAIL TAX STATEMENTS AS DIRECTED ABOVE Z--. File No: 617692999 EXHIBIT "A""41SIST0CERTIFY THAT THIS IS.«;F;:E kl41) CORRECT COPY OF THE ORiG NAL HE320F ' I GY: Pt'r'v I !ilk wr FE -U -h 55RECIS �CPCnv, MIC THE LAND REFERRED TO HEREIN IS SITUATED IN THE COUN MY OF RIVERSIDE, STATE OF CALIFORNIA, AND IS DESCRIBED AS FOLLOWS: LOT 2 CF TRACT NO. 28409, IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALiFOi NIA- AS PER MAP RECORDED IN BOOK 295, PAGES 81 THROUGH 84, INCLUSIVE OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY, ASSESSOR'S PARCEL NUMBER: 773-360-002-4 =LTA Preliminary Reoort Form - M;ocified (11-17-06) Page Building Permit Number: 1 Project Description: New Room Addition Exempt: ❑ (Materials may contain hazardous wastes and am not subject to recycling provisions) — `r Construction Debris Management Plan Plan Submittal Date 1 3/25/2019 Job Site Address/ 77234 Casa Del Sol Owner's Name Number, Street, or PO Box City, State, Postal Code Owners Phone Number Owners E -Mail Address Project Managers Name Project Managers Phone Number Project Managers E-mail Address Greg & Tem Gervais 77234 Casa Del Sol La Quints, Ca. 92253 c/o 760-775-1234 Ish Coronel 760-775-1234 cor nelaffice ronelent.com REC�BVED APR 16 7019 Builder/Contractor Coronel Enterprises CIT1OFLA•QUINTA Number, Street or PO Box 42760 Madio St COMP"Nny')WELOPMEWT City, State, Postal Code Indio, Ca. 92201 Project Square Footage Approx. 3,353 sq ft City Approval By Renado Gouldlock-DECBurrtec Waste Date of City Approval 25 /Jg Is To Be Discarded: Product Trash Asphalt Brick/Block Cardboard Commingled Concrete Drywall Donated / Reuse" "Describe Items Tons 13.50 Not recyclable 0.00 Recyclable 0.00 Recyclable 0.00 Recyclable 14.50 Recyclable 1.50 Recyclable 0.00 Recyclable Product Tons Masonry (broken) 0.00 Plaster 3.75 Scrap Metal 0.00 Tile (floor) 0.20 Tile (roof) 0.40 Wood 5,50 Landscape Debris 0.00 Totals: Recycle Trash Projected Diversion: 25.911 13.5 F65.69 . Recyclable I understand It Is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, ft DMP is still issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the Dm, ire adhered to. The property awn (t).and general contractor shall be kept informed of the diversion progress through bi-monthly reports. If self -hauling, all ref se fnateria I from this project site must be taken to an approved recycler or transfer Owner 1'Developer 1 Project Manager 1 Superintendent Date Domestic Water System Flow Analysis AT Coachella Valley Water District 75515 Hovley Lane East Palm Desert, CA 92211 Domestic Water System Flow Analysis (Hydraulic Model) Requested By: CORONEL ENTERPRISES, INC. Date: 1/29/19 T Address: 42760 MADIO STREET APN: INDIO, CA 92201 Req. Fire Flow: gpm at 20psi for hours. Contact Name: ISH CORONEL Project Name: 77234 CASA DEL SOL. LA QUINTA Phone: 760-775-1234 Email: coroneloffice@coronelent.com Cell: Domestic Water System FIRE FLOW ANALYSIS -HYDRANT CLOSEST TO 77234 CASA DEL SOL, LA QUINTA, GEO 6-6-1-3, Flow Analysis Location: PZ 19-9631 Model Information Flow Analysis Description •"'Lo Requested • Test 1 Test 2 Test 3 Test 4 Flow Domestic Elevation (Ft): 66 None system flow available without Steady State, Dynamic (psi): 86.26 Residual Pressure (psi): 79.11 — exceeding Fire Flow Tested (gpm): 750 N/A Combined Total: N/A criteria. Tested Model Junction: J1956 Duration: 2 hours Demand Conditions: Peak Day Demand (PDD) Reservoir No./Level (s): 6630-1/24.63' Pumps Operating No's: Pumps On Pressure Zone and HGL: Lower La Quinta (235') Model Casa Del Sol FF-CVWD DomesticWater 012616 Comments: The domestic water system is capable of providing 750 gpm for 2 hours that satisfies CVWD's minimum pressure, velocity, and/or head loss criteria. This simulated system flow analysis may not include all facilities that may be required for this development/project. Please check with Development Services for further information on all required facilities. The theoretical flow to drop the residual pressure to 20 psi is 2,750 gpm. Please note the theoretical flow exceeds CVWD's design criteria on the domestic water network. These results are based on hydraulic modelling and not a guarantee that CVWD's domestic water system will have the capacity to supply water to the project at the flows or pressures indicated. It is important to note that the capacity of the on-site fire system, meters, service lines, backflow assemblies and other appurtenances were not considered in this analysis, which may alter actual flows or pressures. Due to continuous changes in the system, CVWD only considers this system flow analysis valid for six months from date of modelling/analysis. These system flow analysis comments are for plan check purposes only. The ultimate design responsibility resides with the Engineer -of -Record for this Project. Should you have any questions or need additional information, please contact me at (760) 398-2661, ext. 2397. 4_��&� Completed By: "- FEB 15 2019 Date: -2-Z/ r •a —� Page 1 of 1 ENG DS -016 `'C (8/31/15) SRIL } I t I 1 1 I I l i i + 1 1 1 I I i I 1; 1 � •I 1' Fire Flow Analysis jj • r , hydrant s GEO 6-6-1-3 -------------------------------- WF: ----------------WF: 801151 (PZ 19-9631) Tech: Ruben IP � - �--',• ..,test j I I 1 r I i I I I e il•i�i� l 1 U.FS 2b (F- c)q 11 CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 9/25/2009 Green Sheet approvals are forwarded to the Building & Safcty Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date:/:J(d Developer: 0 tJ V 1 vt n 1, �- Tract No.: ��� Tract Name: i f���S �t' �rk?C SLot No. (s): Address(s): 1La } { '� Phone Number: The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the Building & Safety Department: CUSTOM HOMES: PROVIDE. ITEMS #2, #3, #4, #5 & #7 BELOW TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1, #2, #3, #5 & #7 BELOW WALLS, SIGNS, OTHER: PROVIDE ITEM #6 BELOW 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation Certificate can be provided. 2. Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils Engineer. Recently rough graded residential developments which have a previously approved geotechnical certification are exempt from this requirement. 3. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots. 4. Complete the attached < 1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 certification number is required. 5. Attach a copy of the rough or precise grading plan to the Public Works Department showing building location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain development plan. 6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. 7. Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW approved building construction projects require either a WQMP or a completed WQMP exemption form. Approved maps/plans may be viewed at the following link: http://www.la-ciuinta.org/PlanCherk/m search.aspx I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff. i, Recommended by: Date: -�) / f T/ 1 67 Public Works Distribution: ( _-)` Green Sheet to Building & Safety ( ► Green Sheet to Planning Department Declined for approval for reason(s) as follow(s), please correct and resubmit: T:\Checklists - Forms & Applications\Forms & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 10-02-12.doc MAR 13 2019 City of La Quinta - PM10 Fugitive Dust Control Project Information Construction Phase PM 10 Agreement (< 1 acre/lot or Infill Protect) Information Project Phase (check one) Construction Demolition Total Acres in Active Construction (< 1 acre per Lot): Contractor: Project Name: Project Tract/Lot Numbers: MTM 2s11-110 Cl "2- Project 2Project Street Address: l Anticipated Start Date: 03_//� Anticipated Completion Date: PM10 Contact Information Please note: Dust control is required 24 hours a day, 7 days a week, regardless of construction status. Person listed below is responsible for dust control during business and non -business hours. Name: La 0'C \ 1 Title•�eSlc� Company Name: — e S Mailing Address: State, ZIP Code: ib CAA Cl? Primary Phone #: Fax #:-1 7�5' 24 Hour Emergency Phone#: Cell Phone #: --I ( d) --Rjo— Email Address: i Qi(_')Y-k�rvt l - -7LAk-4U __ _2D 3 UF7 l PM 10 Certificate #; I �V �� V �� ZS' LA I �( LQ The above stated property owner (or authorized representative): ❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. ❖ Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; ❖ Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes; ❖ Sha'' old harmless the City/County and its representatives from liability for any actions related to this dust n6 trol plan or any City/County initiated abatement activi[ Signatur of/Pyo r 0*ffer or Authorrz-Rejar_" a Date Water Quality Management Plan (WQMP) Exemption Form - Whitewater River Region Documentation of Project Not Requiring a WQMP but Reguiring Site Desmon BMPs and Source Control BMPs by Entitlement Conditions of Approval or Permit Conditions — WQMP Required for the Listed Change of Land Uses or for Changes of Pollutant Stream (All Questions Below Must be Answered "No" To Exempt Project) Entitlement or construction of new single-family hillside residence(s) that create 10,000 square feet, or more, of impervious area where the pre -development natural slope is 25% or greater? Yes No / Entitlement or construction of new single-family hillside residence(s) that create 10,000 square feet, or more, of impervious area where the pre -development natural slope is 10% or greater where erosive soil conditions are known? Entitlement or construction of new commercial and industrial development(s) of 100,000 square feet or more? / Entitlement or construction 'of new automotive repair shop(s) including body, upholstery, paint, exhaust, tire, transmission, engine or other automotive specialty repair. [Standard Industrial Classification (SIC) codes 5013, 7532, 7533, 7534, 7537, 7538, and 75391? Entitlement or construction of new retail gasoline outlet(s) disturbing greater than 5,000 square feet? / / / / Entitlement or construction of new restaurant(s) (or potential restaurant shell space) disturbing greater than 5,000 square feet? , Entitlement or construction of new home subdivision(s) with 10 or more housin units? Entitlement or construction of new parking lot(s) of 5,000 square feet or more, or with 25 or more parking spaces, and potentially exposed to Urban Runoff? Applicant Information Name and Title 1`C&DYVAC L�� Company j� �� r Phone LA Email n I w 1 Project Information Project Name Type (SFH, Multi -Family, Commercial, Etc.) 1Y� VIA Location or Street Address Nearest Cross Streets,�� Municipality/County/Zip Code La Quinta Tract Number(s) and/or Assessor Parcel Number(s) (- �1 \-0+2- -1-1?2-3U 0 Other Location Information Watershed Whitewater River Source Control BMP Information Size of Project Area (nearest 0.1 acre) 220 bLit Project Area managed with Site Design or Low Impact Development (LID) BMPs (nearest 0.1 acre) Is the project subject to onsite retention by City ordinance or policy? Name of the Entity that will implement, operate, and maintain the Source Control BMPs vcJ` Contact Name Street or Mailing Address ti j Lad to rr City Tww Zip Code jw, Check Item To be Performed Source Control BMP Requirements - All Projects Require Non -Structural BMP Source Control Non -Structural BMP (See Appendix H, Section 4.5.2.1) Ongoing Irrigation System and Landscape Maintenance Ongoing Litter Control i Ongoing Drainage System Inspection & Maintenance i Education/Training for Property Owner, Operators, Occupants, or Employees Activity Restrictions — Prohibition of Debris Blowing/Sweeping/Washing into Street/Storm Drain, Closed Trash Lids, Restriction of Vehicle Washing Ongoing Street Sweeping at Private Streets and Private Parking Lots Source Control BMP Requirements — Small Sloped Lots, Small Commercial, < 10 Unit Subdivisions, < 5,000 Square Ft. Parking Lots, Etc. Structural BMP (See Appendix H, Section 4.5.2.2) Check Item To be Provided Storm Drain Inlet Stenciling and Signage Landscape and Irrigation System Design to Minimize Erosion & Nuisance Runoff Protection of Slopes and Channels to Minimize Erosion Multi -Family Project Use of Community Car Wash Racks Wash Water Controls for Food Preparation Areas to Use Sanitary Sewer Fueling Area (Design & Maintenance) Including PCC Surface, Canopy & Spill Prevention Air/Water Supply Area Drainage (Design & Maintenance) Including Spill Area Containment Trash Storage Areas (Design & Maintenance) Including Attached Lids, Storm Water Controls Loading Docks (Design & Maintenance) Including Storm Water Controls, Dry & Frequent Cleaning Procedures Maintenance Bays (Design & Maintenance) Including Indoor Location & Storm Water Containment Vehicle and Equipment Wash Areas (Design & Maintenance) Including Canopy & Containment Outdoor Material Storage Areas (Design & Maintenance) Including Canopy & Containment Outdoor Work Areas or Processing Areas (Design & Maintenance) Including Canopy & Containment CC&R's, Maintenance Agreements or Other mechanisms will be used to ensure the ongoing operation, maintenance, funding, transfer and implementation of the project -specific WQMP requirements. Legal description and plat stamped by Registered Surveyor to be attached to the applicable CC&R or Maintenance Agreement for recordation at Riverside County. (Optional Requirement to be reviewed on a Project by Project basis) BMP Acknowledge The applicant shall comply with listed BMPs and applicable provisions of the City's NPDES stormwater discharge permit, LQMC Sections 8.70.010 et seq. (Stormwater Management and Discharge Controls), and 13.24.170 (Clean Air/Clean Water); Riverside County Ordinance No. 457; the California Regional Water Quality Control Board — Colorado River Basin Region Board Order No. 137-2008-0001 and the State Water Resources Control Board's Order No. 99-08-DWQ. Signature: Print Name:k Title: )=�,, Date:/_13_d� Phone: (-)LLC)) ��� 11-3,J Applicant Certification I certify that I have read this form in its entirety and understand the City's submittal and review process and the Signature: requirements for this form. I understand and agree that if during the processing of the form, it is determined the Print Name: information contains errors or omissions, clarification and/or supplemental information may be required and the Title: t preparation of such information may be considered, in the Community Development Director's judgment, an Date: 2 P21 � unreasonable delay and will result in a suspension of processing time limits in accordance with the California Code f phone: 1](Z) -]-7S l 2 2-,y of Regulations, Title 14, Section 15109. Owner Certification I certify under the penalty of the laws of the State of California that I am the property owner of the property that is the subject matter of this application and I am authorizing and hereby do consent to the filling of this application and acknowledge that the final approval by the City of La Quinta, if any, may result in restriction, limitations and construction obligations being imposed on this real property. Signature: Print Name: Title: Date: / Phone:l BUILDING ENERGY ANALYSIS REPORT � -7 Z 3 y GesR 19 6?!�- soL PROJECT: Gervais Residence Lot 2 - Casa Del Sol La Quinta, CA 92253 Project Designer: CITY OF LA QUINTA y - BUILDING DIVISION ° REVIEWED FOR CODE COMPLIANCE DATE BY � Je Rios Designs 901 Cinnabar Lane achella , Ca 92236 760-485-7431 port Prepared by: Joan Hacker Insu-form, Inc. 43585 Monterey Avenue, Suite 7 Palm Desert, Ca 92260 760-345-1352 Job Number: Date: 12/12/2018 RE;�:FlVED DEC 18 2018 C1 ! Y i, 7 r- i r'� r� i i r h± ;r A r :VL Of MENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www energysoft.com I TABLE OF CONTENTS 1 Cover Page 1 ` Table of Contents 2 Form CF -1 R -PRF -01-E Certificate of Compliance 3 Form RMS -1 Residential Measures Summary 13 Form MF -1 R Mandatory Measures Summary 14 HVAC System Heating and Cooling Loads Summary 18 ....... ... ............. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 14:56, Wed, Dec 12, 2018 Calculation Description: Title 24 Analysis Input File Name: Gervis Residence. ribd 1 6x CF1 R -PRF -01 Page 1 of 10 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name Single Family Residence 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ftZ-yr) 03 Project Location Lot 2 - Casa Del Sol Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 135 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ftZ) 3353 15 Number of Zones 2 16 Slab Area (ftZ) 3353 17 Number of Stories 1 78 Addition Cond. Floor Area(ftZ) n/a 19 Natural Gas Available I Yes 20 Addition Slab Area (ftZ) n/a 21 Glazing Percentage (%) 34.9% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 418-P010098313A-000-000-0000000-0000 Registration Date/Time: 12/12/2018 16:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-12 14:57:32 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ftZ-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 5.15 9.70 -4.55 -88.3% Space Cooling 104.61 100.13 4.48 4.3% IAQ Ventilation 0.87 0.87 0.00 0.0% Water Heating 3.87 3.41 0.46 11.9% Photovoltaic Offset Compliance Energy Total — 114.50 0.00 114.11 0.00 0.39 --- 0.3% Registration Number: 418-P010098313A-000-000-0000000-0000 Registration Date/Time: 12/12/2018 16:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-12 14:57:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Dateitime: 14:56, Wed, Dec 12, 2018 Calculation Description: Title 24 Analysis Input File Name: Gervis Residence. ribd16x CFI R -PRF -01 Page 2 of 10 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed EfficiencyEDR Value of Proposed PV + Battery Final Proposed EDR 53.3 53.1 0.0 53.1 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on-site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • -- None -- Registration Number: 418-P010098313A-000-000-0000000-0000 Registration DateMme: 12/12/2018 16:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-12 14:57:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 14:56, Wed, Dec 12, 2018 Calculation Description: Title 24 Analysis Input File Name: Gervis Residence. ribd16x BUILDING - FEATURES INFORMATION 01 02 03 04 05 Number of Dwelling Project Name Conditioned Floor Area (ftZ) Units Number of Bedrooms Number of Zones Single Family Residence 3353 1 3 2 ZONE INFORMATION 01 02 Zone Name Zone Type Zone 1 Conditioned Zone 2 Conditioned 06 Number of Ventilation Cooling Systems 0 CF1 R -PRF -01 Page 3 of 10 07 Number of Water Heating Systems 1 03 04 05 06 07 Zone Floor Area Avg. Ceiling HVAC System Name (ftZ) Height Water Heating System 1 Water Heating System 2 Zone 11 1377 111 DHW Sys 1 n/a Zone 22 1976 11 DHW Sys 1 n/a OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ftZ) Window & Door Area (ftZ) Tilt (deg) Front Wall Zone 1 R-21 Wall 135 Front 420 185.5 90 Left Wall Zone 1 R-21 Wall 225 Left 500 0 90 Rear Wall Zone 1 R-21 Wall 315 Back 800 416 90 Right Wall Zone 1 R-21 Wall 45 Right 500 0 90 Interior Surface Zone 1 —Zone 2 R-21 Wall1 n/a n/a 1 0 n/a Roof Zone 1 R-38 Roof Attic n/a n/a 1377 n/a n/a Front Wall 2 Zone 2 R-21 Wall 135 Front 420 90 90 Left Wall 2 Zone 2 R-21 Wall 225 Left 500 84 90 Rear Wall 2 Zone 2 R-21 Wall 315 Back 800 271 90 Right Wall 2 Zone 2 R-21 Wall 45 Right 500 125 90 Roof 2 Zone 2 R-38 Roof Attic n/a n/a 1976 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Zone 1 Attic RoofZone 1 Ventilated 0 0.5 0.75 Yes Yes Attic Zone 2 Attic RoofZone 2 Ventilated 0 0.5 0.75 Yes Yes Registration Number: 418-P010098313A-000-000-0000000-0000 Registration Date/Time: 12/12/2018 16:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance ReportVersion - CF1 R-11302018-1149 Report Generated at: 2018-12-12 14:57:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 14:56, Wed, Dec 12, 2018 Calculation Description: Title 24 Analysis Input File Name: Gervis Residence. ribd 1 6x CF1 R -PRF -01 Page 4 of 10 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (W) U -factor SHGC Exterior Shading Window Window Front Wall (Front -135) 8.0 8.0 1 64.0 0.40 0.29 Insect Screen (default) Window 2 Window Front Wall (Front -135) 1.5 10.0 1 15.0 0.40 0.29 Insect Screen (default) Window 3 Window Front Wall (Front -135) 6.0 10.0 1 60.0 0.40 0.29 Insect Screen (default) Window 4 Window Front Wall (Front -135) 1.5 10.0 1 15.0 0.40 0.29 Insect Screen (default) Window 5 Window Front Wall (Front -135) 2.0 2.5 1 5.0 0.40 0.29 Insect Screen (default) Window 6 Window Front Wall (Front -135) 2.0 2.5 1 5.0 0.40 0.29 Insect Screen (default) Window 7 Window Front Wall (Front -135) 2.0 2.5 1 5.0 0.40 0.29 Insect Screen (default) Window 8 Window Front Wall (Front -135) 11.0 1.5 1 16.5 0.40 0.29 Insect Screen (default) Window 9 Window Rear Wall (Back -315) 4.0 7.0 1 28.0 0.40 0.29 Insect Screen (default) Window 10 Window Rear Wall (Back -315) 4.0 2.5 1 10.0 0.40 0.29 Insect Screen (default) Window 11 Window Rear Wall (Back -315) 10.0 10.0 1 100.0 0.40 0.29 Insect Screen (default) Window 12 Window Rear Wall (Back -315) 100 2.5 1 04 26.0 0.40 0.29 Insect Screen (default) Window 13 Window Rear Wall (Back -315) 10.0 2.5 4 100.0 0.40 0.29 Insect Screen (default) Window 14 Window Rear Wall (Back -315) 10.0 2.5 1.04 26.0 0.40 0.29 Insect Screen (default) Window 15 Window Rear Wall (Back -315) 10.0 10.0 1 100.0 0.40 0.29 Insect Screen (default) Window 16 Window Rear Wall (Back -315) 10.0 2.5 1.04 26.0 0.40 0.29 Insect Screen (default) Window 17 Window Front Wall 2 (Front -135) 2.0 2.5 1 5.0 0.40 0.29 Insect Screen (default) Window 18 Window Front Wall 2 (Front -135) 2.0 2.5 1 5.0 0.40 0-29 Insect Screen (default) Window 19 Window Front Wall 2 (Front -135) 8.0 10.0 1 80.0 0.40 1 0.29 Insect Screen (default) Window 20 Window Left Wall 2 (Left -225) 6.0 7.0 1 42.0 0.40 0.29 Insect Screen (default) Window 21 Window Left Wall 2 (Left -225) 3.0 6.0 1 18.0 0.40 0.29 Insect Screen (default) Window 22 Window Left Wall 2 (Left -225) 3.0 3.0 1 9.0 0.40 0.29 Insect Screen (default) Window 23 Window Left Wall 2 (Left -225) 6.0 2.5 1 15.0 0.40 0.29 Insect Screen (default) Window 24 Window Rear Wall 2 (Back -315) 8.0 10.0 1 80.0 0.40 0.29 Insect Screen (default) Window 25 Window Rear Wall 2 (Back -315) 8.0 7.0 1 56.0 0.40 0.29 Insect Screen (default) Window 26 Window Rear Wall 2 (Back -315) 10.0 10.0 1 100.0 0.40 0.29 Insect Screen (default) Window 27 Window Rear Wall 2 (Back -315) 5.0 7.0 1 35.0 0.40 0.29 Insect Screen (default) Window 28 Window Right Wall 2 (Right -45) 7.0 10.0 1 1 70-0 0.40 0.29 Insect Screen (default) Window 29 Window Right Wall 2 (Right -45) 5.0 7.0 1 35.0 1 0.40 0.29 1 Insect Screen (default) Registration Number: 418-P010098313A-000-000-0000000-0000 Registration DateRme: 12/12/2018 16:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance ReportVersion - CF1 R-11302018-1149 Report Generated at: 2018-12-12 14:57:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 14:56, Wed, Dec 12, 2018 Calculation Description: Title 24 Analysis Input File Name: Gervis Residence. ribd 1 6x CF1 R -PRF -01 Page 5of10 Window 30 Window Right Wall 2 (Right -45) 2.0 2.5 1 5.0 0.40 0.29 Insect Screen (default) Window 31 Window Right Wall 2 (Right -45) 6.0 2.5 1 15.0 0.40 0.29 Insect Screen (default) Registration Number: 418-P010098313A-000-000-0000000-0000 Registration DateRme: 12/12/2018 16:46 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 HERS Provider: CHEERS Report Generated at: 2018-12-12 14:57:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 14:56, Wed, Dec 12, 2018 Calculation Description: Title 24 Analysis Input File Name: Gervis Residence. ribd 1 6x CF1 R -PRF -01 Page 6 of 10 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 2 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Window 3 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 4 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 7 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 8 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Window 9 14 0.1 14 14 0 0 0 0 0 0 0 0 0 Window 10 14 0.1 14 14 0 0 0 0 0 0 0 0 0 Window 11 14 0.1 14 14 0 0 0 0 0 0 0 0 0 Window 12 14 01 14 14 0 0 0 0 0 0 0 0 0 Window 13 14 0.1 14 14 0 0 0 0 0 0 0 0 0 Window 14 14 0.1 14 14 0 0 0 0 0 0 0 0 0 Window 15 14 0.1 14 14 0 0 0 0 0 0 0 0 0 Window 16 14 0.1 14 14 0 0 0 0 0 0 0 0 0 Window 17 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 18 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 19 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 20 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 21 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 22 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 23 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 24 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 25 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 26 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 27 2 1 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 28 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 418-P010098313A-000-000-0000000-0000 Registration Dateffime: 12/12/2018 16:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-12 14:57:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: Single Family Residence Calculation Date/Time: 14:56, Wed, Dec 12, 2018 Page 7 of 10 Calculation Description: Title 24 Analysis Input File Name: Gervis Residence. ribd 1 6x Window 29 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 30 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 31 2 0.1 2 2 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 02 03 04 05 Total Cavity Winter Design Name Construction Name Surface Type Construction Type Framing R -value U -factor Assembly Layers Zone 1 1377 998 None 1 No • Cavity/ Frame: no insul. / 2x4 Top Chrd Zone 2 1976 998 2x4 Top Chord of Roof Truss @ 24 1 No Roof Deck: Wood Siding/sheathing/decking Attic RoofZone 1 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 R-21 Walll Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.064 Other Side Finish: Gypsum Board • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofZone 2 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated Slab -on -Grade Zone 1 1377 998 None 1 No Slab -on -Grade 2 Zone 2 1976 998 None 1 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 (1) 1 .0% Registration Number: 418-P010098313A-000-000-0000000-0000 Registration Date[Time: 12/12/2018 16:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-12 14:57:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 14:56, Wed, Dec 12, 2018 Calculation Description: Title 24 Analysis Input File Name: Gervis Residence. ribd 1 6x CF1 R -PRF -01 Page 8 of 10 WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Zone 11 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Input Rating / Tank Standby Cooling Component 2 HVAC Fan 2 Air Distribution System 2 2 Heater 18 Not Zonal Tank Uniform Energy Pilot / Insulation Loss / First Hour NEEA Heat Pump Tank Location Element Number Volume Factor / Energy Thermal R -value Recovery Rating / Brand / Model / or Ambient Name Type Tank Type of Units (gal) Factor/ Efficiency Efficiency (Int/Ext) Eff Flow Rate Other Condition DHW Heater 1 Gas Small Storage 1 75 L 0.98 EF — 75 kBtu/hr R -0/R-0 0 n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Zone 11 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Zone 22 L Other Heating and Cooling I System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC - HEATING UNIT TYPES 01 02 03 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace 1 80 AFUE Heating Component 2 CntrlFurnace 2 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 14 18 Not Zonal Single Speed Cooling Component 1 -hers -cool Cooling Component 2 SplitAirCond 2 14 18 Not Zonal Single Speed Cooling Component 2 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 350 Required Required Required Cooling Component 2 -hers -cool Required 350 Required Required Required Registration Number: 418-P010098313A-000-000-0000000-0000 Registration DateRme: 12/12/2018 16:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-12 14:57:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 14:56, Wed, Dec 12, 2018 Calculation Description: Title 24 Analysis Input File Name: Gervis Residence. ribd 1 6x CFI R -PRF -01 Page 9 of 10 HVAC - DISTRIBUTION SYSTEMS 01 02 01 01 02 03 01 Name 02 03 04 HVAC Fan 1 Single Speed PSC Furnace Fan 05 06 07 Name 0.58 Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 1 -hers -dist Air Distribution System 2 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 2 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1 -hers -dist Required 6.0 Not Required Not Required Not Required Not Required Required Air Distribution System 2 -hers -dist Required 5.0 Not Required I Not Required Not Required Not Required Required HVAC -FAN SYSTEMS 01 02 01 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 HVAC Fan 2 -hers -fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 64 0.25 Default 0 Required Registration Number: 418-P010098313A-000-000-0000000-0000 Registration DateMme: 12/12/2018 16:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance ReportVersion - CF1 R-11302018-1149 Report Generated at: 2018-12-12 14:57:32 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 14:56, Wed, Dec 12, 2018 Input File Name: Gervis Residence. ribd 1 6x CF1 R -PRF -01 Page 10 of 10 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Joan Hacker Jaa#vRac1e'- Company: Signature Date: Joan Hacker 12/12/2018 Address: CEA/HERS Certification Identification (If applicable): 72875 Fred Waring Drive City/State/Zip: Phone: Palm Desert, CA 92260 760-345-1352 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Gabriel Rios Company: Date Signed: Rios Designs 12/12/2018 Address: License: 49-901 Cinnabar Lane City/State/Zip: Phone: Coachella, CA 92236 760-485-7431 Registration Number: 418-P010098313A-000-000-0000000-0000 Registration Dateffime: 12/12/2018 16:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-12 14:57:32 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Gervais Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 12/12/2018 Project Address Lot 2 - Casa Del Sol La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,353 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity fe) S ecial Features Status Wall Wood Framed R 21 3,270 New Roof Wood Framed Attic R 38 3,353 Cool Roof New .......... Slab Unheated Slab-on-Grade - no insulation 3,353 Perim = 1996' New FENESTRATION Total Area: 1, 172Glazing Percents e: 34.9°% NewlAltered Average U-Factor Orientation Area(ft) U-Fac SHGC Overhang Sidefins Exterior Shades 4.40 Status Front (SE) 244.0 0.400 0.29 2.0 none Bug Screen New .......... Front (SE) 31.5 0.400 0.29 6.0 none Bug Screen New Rear (NVV) 416.0 0.400 0.29 14.0 none Bug Screen New Left (SVV) 84.0 0.400 Rear (NVtq 271.0 0.400 0.29 2.0 none Bug Screen 0.29 2.0 none Bug Screen New New Right (NE) 125.0 0.400 0.29 2.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 18.0 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 18.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status Zone 1 Ducted Ducted Attic 8.0 New Zone 2 Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Storage Gas 75 0.98 Standard New Ener Pro 7.2 by EneroySoft User Number: 2655 /D: Pae 13 of 19 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. *Exceptions may apply. rpi,vigPri n4nn17! Building Envelope Measures: § 110.6(a)l: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per NFRC-400 or ASTM E283 or AAMAIWDMAICSA 101/I.S.2/A440-2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U -factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.80) when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U -factor must not exceed 0.043 Minimum R-19 or weighted average U -factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R -value. Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a Ll -factor of 0.102 or less (R-19 in 2x6 or U- § 150.0(c): factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U -factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.' § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U -factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration: and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This § 150.0(g)1: requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0 d . Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the ccndiIioned space side of all § 150.0(g}2: nsulation in all exterior walls, vented attics, and unvented attics with air- ermeab€e insulation. § 150.0(q): Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U -factor of 0.58; or the weighted aver 22e U -f actor of all fenestration must not exceed 0.58: Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)lA: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)1C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.* § 110,2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU)hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with piiol lights that consume less than 150 Stulhr are exempt); and pool and spa heaters.' Building Cooling and Beating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions specified in § 150.0(h)2. 2016 Low -Rise Residential Mandatory Measures Summarv° Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet Rom the outlet of any §150.0(h)3A: dryer vent. Liquid Line Drier. Installed air conditioner and Beat pump systems must be equipped with liquid line filter driers if required, as specified by § 150.0(h)3B: manufacturer's instructions. Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have § 150.00)1: R-12 external insulation or R-16 internal insulation where the internal insulation R-value'is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof § 150.00)2B: and non -crushable casing or sleeve." Water piping and cooling system line insulation. Pipe for cooling system fines must be insulated as specified in § 150.00)2A, Distribution § 150.00)2C: piping for steam and h dronic heating systems or hot waters stems must meet the r ulrements in TABLE 120.3-A' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. Insulation Protection. insulalion covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a § 150.00)3B: Class I or Class I I vapor retarder. Gas or Propane Systems. Systems u5mg gas or propane water heaters to serve individual dwelling units must include all of the following: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside § 150.0(n)l. termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and all natural drainin without tom assistance; and a as su I line with a Ca ap . of at least 200,000 Btulhr, § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification § 150.0(n)3: Corporation SIRCC or hy a listing agency that is approved by the Executive Director. Ducts and Fans Measures: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a § 110.8(d)3: contractor installs the insulation, the contractor must certil[y to the customer, in wr;lin , that the insulation meets this requirement. CMC Compliance. All air -distribution system duc!s and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI ISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened Openings must be sealed with § 150.0(m)l mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181. UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than %inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and supELft platforms must not be compressed to cause reductions in the cross-sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply wilh applicable requirements for duct construction, § 150.0(m)2 connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tap2 is used in combination with mastic and draw bands. Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, § 150.0(m)3: mastics, sealants, and Other re uirements s ecified for duct construction. Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or § 150.0(m)7: automatic dampers. Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, § 150.0(m)8: manually operated dampers in all openings to the outside, except combustion inlet and outlet air openiand elevatorshaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or § 150.0(m)9: plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)l l occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with 150.0 m t 1 and Reference residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space lhrourah ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure dfOI)r and labeft requirements of fi 11510.1)(m) 12. i7llk2016 Low -Rise Residential Mandatory Measures Summa Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airf low > 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs tems ' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(0): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of rovidi whole-buildingventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing. in accordance with Reference Residential Appendix RAV. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.' § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines or built in ar built u connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a lime switch that will allow all ximps to be set or pLogrammed to run only during off-peak electric demand enols § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow § (p)' rate. Dioina. Fillers, and valves." Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of 5 110.9.' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission aecordin to Reference Joint A endix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1 C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilin s. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 wafts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vac a ncy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of 5 150.0(k)-' Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1G: with Reference Joint Appendix JA8. Installed lamps must be marked with *JA8-2016" or "JA8-20]6-E' as specified in Reference Joint Appendix JA8.' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E.' § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor funclion if the control is installed to comply with 150.4 k § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCs) may be used to comply with dimmer requirements if It: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5ft and meets all other r uirements in 150.0(k)2. Interior Switches and Controls. An FMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.6(0: and all other requirements in § 150.0 k 2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it ❑rovides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in 150.O(k)2. kmh 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint A ndix JAB, exce I luminaires in closets fess than 70 s uare feet and luminaires in hallwa s.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either 150.0(k)3A or with the applicable r uirements in 110.9, 130.0. 130.2, 130-4. 140.7 and 141-0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150-0(k)3B or § '150.0(k)30 mustcomply with the applicable requirements in §§ 110.9, 130.0, 130-2. 130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles r site mustcomply with the applicable requirements in q 110A 130.0. 130.2, 130.4. 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of ower as determined according to.§ 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the a licable r uirements for nonresidential araqes in §§ 110.9, 130.0. 130.1, 130.4, 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)613: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1. 140.6 and 1410; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all desi ped paihs of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of 110.1 0 b through § 110.1 0 e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1. greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110,10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features. and roof mounted equipment.' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clear!y indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service ane) : and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 1 10.10 c must be provided to the occupant. § 110.10(e)1. Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location-. and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Gervais Residence 12/12/2018 System Name Floor Area Zone 1 1,377 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,133 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 64,800 26,639 1,433 1,463 52,164 Total Output Btuh) 64,800 0 Output Btuh/s ft 47-1 1,538 2,564 Cooling System_ 0 0 output perSystem 47,000 0 0 0 0 Total Output Btuh) 47,000 0 1,433 0 Total Output Tons 3.9 1,538 2,564 Total Output Btuhls ft 34.1 Total Output s ft/Ton 351.6 29,715 57,291 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 CARRIER 48SSO48080511 36,166 4,160 64,800 Airflow (cfm/s ft) 1.16 Airflow (cfm/Ton) 408.5 64,800 Outside Air (%) 0.0% Total Adjusted System Output 36,166 (Adjusted for Peak Design conditions) 4,160 0.00 Outside Air cfm/s ft 1 TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 68 OF 105 IF Outside Air 0 cfm Supply Fan Heating Coil 103 IF 1,600 cfm ROOM 68 IF 70 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak 112/78°F 79/63°F 79/63°F 55/54°F Q - Outside Air Ar 0 cfm Supply Fan Cooling Coil 56 / 54 IF 1,600 cfm 42.0% ROOM 78 / 62 OF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Gervais Residence 12/12/2()1 A System Name Zone 2 at Time of Heating Peak 69 IF 69 IF 105 °F Floor Area 1,976 ENGINEERING CHECKS —*—� M SYSTEM LOAD IR I Outside Air Number of Systems 2 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 1,221 0 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent I CFM Sensible Output perSystem 53.000 29,155 2,056 1,480 53,710 Total Output Btuh 106,000 0 69 IF Output Btuh/s ft 53.6 1,683 2,640 Cooling System 0 0 Output perSystem 35,600 0 0 0 0 Total Output Btuh 71,200 0 2.056 0 Total Output Tons 5.9 1,6831 32,521 2,640 Total Output Btuh/sgft) 36.0 I Total Output s ft/Ton 333.0 58,989 Air System CFM perSystem Airflow cfm 1,395 2,790 HVAC EQUIPMENT SELECTION Carrier 38ETGO3630 53,845 7,101 106,000 Airflow cfm/s ft 1.41 78 / 62 OF Airflow cfm/Ton 470.2 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 53,845 7,101 Aug 3 PM 106,000 F Jan 1 AM Outside Air cfmis ft 0,00 Note: values above given at ARI conditions nr-r, iry%2 a r a 1 tm rb r t mKumt r Kit;z� Airstream temperatures at Time of Heating Peak 69 IF 69 IF 105 °F —*—� M I IR I Outside Air 0 cfm Supply Fan Heating Coil 104 OF 2,790 cfm M�ff 69 IF 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cool Ing Peak) 112 / 78 IF 79163 IF 79 / 63 OF 55 / 54 OF O Outside Air I 0 cfm Supply FanAL Cooling Coil 56 / 54 OF 2,790 cfm 41.9% ROOM -Z 78 / 62 OF