BRES2019-000878-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type/Subtype:
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
c&hr 4 lwQ�w
DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED
BRES2019-0008
77660 CALLE POTRERO
774282023
LENNOX / 1,779 NEW SF DWELLING
$115,454.40
Applicant:
VINCENT LENNOX & APHRODITE VASILOPOULOS
62 COURTLAND DR.
BEDFORD, NH 03110
n Q 0
I__J
APR 0 5 2019
CITY OF LA QUINTA 0
DESIGN & DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
(commencing with Section 70001 of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: License No.:
Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business a
and Professions Code) or that he or she is exempt therefrom and the basis for the
ed exemption. Any violation of Section 7031.5 by any applicant for a permit
cilis the applicant to a civil penalty of not more than five hundred dollars ($500).:
, as owner of the property, or my employees with wages as their sole
nsatlon, will do the work, and the.structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
wy'tN one year of completion, the owne r- b u i I der wi I I have the burden of provi rig that he
_ s_h_ id not build or improve for the purpose of sale.].
f s owner of the property, am exclus[vely contracting with licensed contractors to
uct the project. (Sec. 7044; Business and Professions Code; The Contractors' State
License Law does not apply to an ewner of property who builds or improves thereon,
a who contracts for the projects with a contractor(s) licensed pursuant to the
Coolltrartore State License Law.).
Warn exempt under Sec. B.&P.C. for this reason
CONSTRUCTION 612NDING'AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 4/5/2019
Owner:
APHRODITE VASILOPOULOS
77-660 CALLE POTRERO
LA QUINTA, CA 92253
Contractor:
OWNER BUILD
Llc. No..
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
Issued. y workers'tompensation insurance carrier and policy number are:
Ca Policy Number.-
certify
umber;
certify that in the performance of the work for which this permit is issued, I
s* a employ.
mploy any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 the Labor Code, I shall forthwith
comply with thosse revisions.
Date: ] Ap • .'
r
WARNING: FAILURE TO SECURE WORKERS' MPEN 710N COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CR INAL PENALTIES AND CIVIL FINES UPTO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST. AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalfthis application is made, each person atwhose
request and for whose benefit work is performed under or pursuant to any permit issued
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this 4tter 2theabove-
mentioned
Cp apertyfor inspection purposes.
r r -I SignatUre.(ApplicantorAgent).
Application Number:
BRES2019-0008
Property Address:
77660 CALLE POTRERO
APN:
774282023
Application Description:
LENNOX / 1,779 NEW SF DWELLING
Property Zoning:
Application Valuation:
$115,454.40
Applicant:
VINCENT LENNOX & APHRODITE
VASILOPOULOS
62 COURTLAND DR.
BEDFORD, NH 03110
Owner:
APHRODITE VASILOPOULOS
77-660 CALLE POTRERO
LA QUINTA, CA 92253
Contractor:
OWNER BUILD
Llc. No.:
Date: 4/5/2019
Detail: 1,779SF DWELLING -[VB/RES-3/CLASS A-FR/13D] TH15 PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2016
CALIFORNIA BUILDING CODES.
pni IRI V rpAR(.F - rITV Al III flllklr. CTAFF
Total Paid for BLDG CITY STAFF - PER HOUR: $240.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$5.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $5.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - CIVIC CENTER
252-0000-43200
0
$942.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - COMMUNITY CENTERS
254-0000-43200
0
$129.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - FIRE PROTECTION
257-0000-43200
0
$433.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - LIBRARIES
253-0000-43200
0
$344.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - PARK MAINTENANCE
256-0000-43200
0
$40.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - PARKS/REC
251-0000-43200
0
$2,048.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - STREET MAINTENANCE
255-0000-43200
0
$116.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - TRANSPORTATION
250-0000-43200
0
$2,842.00
Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SERVICES
101-0000-42403
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SERVICES PC
101-0000-42600
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TEMP POWER SERVICE
101-0000-42403
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TEMP POWER SERVICE PC
101-0000-42600
0
$18.68
Total Paid for ELECTRICAL: $85.38
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, EA ADDITION 1,0005F
101-0000-42403
0
$27.22
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF, PC
101-0000-42600
0
$11.20
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$160.10
DESCRIPTION
ACCOUNT
I CITY
AMOUNT
RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 I $52.83
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $251.35
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF
101-0000-42408
0
$40.02
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF
PC
101-0000-42600
0
$40.02
Total Paid for GRADING: $80.04
DESCRIPTION
ACCOUNT
CITY
AMOUNT
CONDENSER/COMPRESSOR
101-0000-42402
0
$40.02
DESCRIPTION
ACCOUNT
CITY
AMOUNT
CONDENSER/COMPRESSOR PC
101-0000-42600
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
EXHAUST HOOD
101-0000-42402
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
EXHAUST HOOD PC
101-0000-42600
0
$5.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FURNACE
101-0000-42402
0
$40.02
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FURNACE PC
101-0000-42600
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN
101-0000-42402
0
$53.36
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN PC
101-0000-42600
0
$21.36
Total Paid for MECHANICAL: $226.80
DESCRIPTION
ACCOUNT
CITY
AMOUNT
MULTI -SPECIES RESIDENTIAL 8.1-14 UNITS - 2018 UPDATE
101-0000-20310
0
$537.00
Total Paid for MULTI -SPECIES RESIDENTIAL: $537.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
NEW CONSTRUCTION PERMIT
101-0000-42400
0
$566.31
Total Paid for NEW CONSTRUCTION PERMIT: $566.31
DESCRIPTION
ACCOUNT
CITY
AMOUNT
NEW CONSTRUCTION PLAN CHECK
101-0000-42600
0
$1,110.78
Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,110.78
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PLAN CHECK DEPOSIT- RESIDENTIAL
101-0000-42600
1
$750.00
Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $750.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BACKFLOW DEVICE
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BACKFLOW DEVICE PC
101-0000-42600
0
$5.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BUILDING SEWER
101-0000-42401
0
$26.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BUILDING SEWER PC
101-0000-42600
0
$18.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$146.74
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$146.74
DESCRIPTION
ACCOUNT
QTY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS PC
101-0000-42600
0
$26.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ROOF DRAIN
101-0000-42401
0
$40.02
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ROOF DRAIN PC
101-0000-42600
0
$40.02
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER HEATER/VENT
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER HEATER/VENT PC
101-0000-42600
0
$8.00
Total Paid for PLUMBING FEES: $498.92
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RECORDS MANAGEMENT FEE - MAJOR
101-0000-42416
0
$21.00
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$15.01
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $15.01
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SINGLE FAMILY DETACHED 2018 UPDATE
224-0000-20320
0
$2,310.00
Total Paid for TUMF - RESIDENTIAL: $2,310.00
ta Qaiara
-- ;L%1 ^J,/, DESERT -
PERMIT # � � (�.• 0 1 el WN'
PLAN LOCATION:
Project Address: 77-660 Calle Potrero
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #: 774-282-023
New single family residence
SF
City, St, Zip
Applicant Name: Vincent Lenox & Aphrodite Vasilopoulos
501
Address: 61 Courtland Dr.
Telephone:
City, ST, Zip: Bedford, NH 03110
172
Telephone: (603) 765-1061
Email:
Email: nuform@comcast.net & aphroditez@comcast.net
Valuation of Project $ $200,000.00
Contractor Name:
New SFD Construction:
Address: 49-901 Cinnabar Lane
Grading: No
Address:
Conditioned Space
1,779
SF
City, St, Zip
Garage
501
SF
Telephone:
Patio/Porch
172
SF
Email:
Fire Sprinklers
2,452
SF
State Lic: City Bus Lic:
Arch/Eng Name: Gabriel Rios
Construction Type: VB Occupancy: R-3
Address: 49-901 Cinnabar Lane
Grading: No
City, St, Zip Coachella, CA 92236
Construction Type: Occupancy:
Telephone: 760-485-7431
Bedrooms: 2 Stories: 1
# Units: N/A
Email: riosdesigns@yahoo.com
State Lic: NIA City Bus Lic:
Vincent Lenox & Aphrodite
Property Owner's Name: Vasilo oulos
New Commercial /Tenant Improvements:
Address: °
Total Building SF
City, ST, Zip
Construction Type: Occupancy:
Telephone:
Email:
78495 CALLE TAMPICO
LA QU I NTA, CA 92253
760-777-7000
Date: 4/4/2019
No.: 19-01295-1
Owner: Vincent Lennox
Address: 77-660 Calle Potrero
City: La Quinta
Type: Single Family Residential
Lot # Street No.
77-660
Comments:
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
o
47950 Dune Palms Road
�`''!�
41 RANC0.ilOn 7ZHE:
r i:;nu a AFu y
La Quinta, CA 92253
'r ,, eft.
(760)771-8515
Email:
Jurisdiction: La Quinta
Tract #:
Street Name Sq. Feet APN Permit No.
Calle Potrero 1779 774-282-023
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fess imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $3.79 X 1779 S.F. or $6,742.41 have been paid for the property listed above and that building
permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Fees Paid By: VISA/Vincent Lenox, Check No.: Credit / Debit Card
Bank Name/Recipient of Certificate Telephone: 603-765-1061
Funding: Residential
By Scott L. Bailey
Superintendent
Fee Collected/ Exempted by: Arianne Catano Certificate Fees Due: $6,742.41
Credit Card Fees Due: $134.85
Original Payment(s) Recd: $0.00
New Payment Rec'd: $6,877.26
Over/cinder: $0.00
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District(`s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
Tit!t44Q"
P.O. Box 1504
LA QUINTA, CALIFORNIA 92247-1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
PROPERTY OWNER'S PACKAGE
(760) 777-7012
FAX (760) 777-7011
Disclosures & Forms for Owner -Builders Applying for Construction Permits
IMPORTANT! NOTICE TO PROPERTY OWNER
Dear Property Owner:
An application for a building permit has been submitted in your name listing yourself as the builder of the property
improvements specified at '77-66 0 6:4 rI e_ Pc_srcry
We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your
responsibilities and possible risk you may incur by having this permit issued in your name as the
Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision,
signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice
unless you, the property owner, obtain the prior approval of the permitting authority.
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION
DIRECTIONS: Read and initial each statement below to sig -H6 you understand or verify this information.
�. 1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder"
building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as
an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those
injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers
XFy property,
2. I understand buildingpermits are not required to be e
p q signed by property owners unless they are responsible for the
1 c ;�Stc nstruCtion and are not hiring a licensed Contractor to assume this responsibility.
3. I understand as an "Owner -Builder" I am the responsible party tyof record on the permit. I understand that I may protect
myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my
qvjpl
I
4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on
eLmits and contracts.
d5. I understand if I employ or otherwise en age an persons, other P Y g g y p than California licensed Contractors, and the total value
of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer"
under state and federal law.
g6. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal
government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment
compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial
Oak
47. I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential
structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed
subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed
under contract with a licensed general building Contractor.
Ca8. I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any
ncial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the
w r nship or materials.
� 9. I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue
Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California
Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-
8 -321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors.
10. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the
party legally and financially responsible for proposed construction activity at the following address:
A11.
I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all
cabic laws and requirements that govern Owner -Builders as well as employers.
12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I
ave provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with
someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss
you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also
important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working
on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors,
you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers'
compensation insurance coverage.
Before a building permit can be issued, this form must be completed and signed by the property owner and returned to
the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or
other verification acceptable to the ag ncy is required to be presented when the permit is issued to verify the property
owner's signature.
Signature of property owner Date:
Note: The following Authorization Form is required to be completed by the property owner only when designating
an agent of the property owner to apply for a construction permit for the Owner -Builder.
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize
the following person(s) ct as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder
Permit for my project.
Scope of Construction Project (or"H.;scription of Work):
Project Location or Address:
Name of Authorized Agent:
Address of Authorized Agent:
Tel No
I declare under penalty of perjury that I am the property owner for the listed above and I personally filled out the above
information and certify its accuracy. Note: A copy of the owner's driver's icensw4crm notarization, or other verification
acceptable to the agency is required to be presented when the permit is issued to ve ' the property owner's signature.
Property Owner's Signature: Date:
Plan Submittal
Job Site
Building Permit Number:
Project Description: SFR
Exempt: I]
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
Owner's Name
Number, Street, or PO Box
City, State, Postal Code
Owner's Phone Number
Owner's E -Mail Address
4/5/2019
77660 Calle Potrero
Vincent Lenox
61 Cortland Dr
Bedford, NH. 03010
603-765-1061
nuform[a�comcast. net
Project Manager's Name Vincent Lenox
Project Manager's Phone Number 603-765-1061
Project Manager's E-mail Address I nufcrm@comcast.net
Builder/ Contractor I Owner/Builder
Number, Street or PO Box1 77660 calle Potrero
City, State, Postal Codel La Quinta, CA. 92253
Project Square Footagel Approx. 1,780 sf
CityApproval By Renado Gouldlock-DEC/Burrtec Waste -
Date of City Approval 0af-105 (1of
Materials To Be Discarded:
Product
Trash
Asphalt
Brick/Block
Cardboard
Commingled
Concrete
Drywall
Donated / Reuse*
*Describe Items
Tons
7.00 Not recyclable
0.00 Recyclable
0.00 Recyclable
0.00 Recyclable
0.00 Recyclable
8.00 Recyclable
0.90 Recyclable
0.00 Recyclable
Totals: Re c cle Trash
13.8 7.0
Product
Masonry (broken)
Plaster
Scrap Metal
Tile (floor)
Tile (roof)
Wood
Landscape Debris
Tons
0.00 Recyclable
2.00 Recyclable
0.00 Recyclable
0.19 Recyclable
0.24 Recyclable
2.50 Recyclable
0.00 Recyclable
Projected Diversion:
66.39%
I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is
diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or
demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still
issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the
DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through
bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer
Owner / Developer / Project Manager / Superintendant
Date
,� CITY OF LA QUINTA SUB -CONTRACTOR_ LIST
JOB ADDRESS 7 7 66G ��� ��'��� �' PERMIT NUMBER 6&ES,1c)15-��o,'J'OWNER 1icy�e e•`�� _ Y BUILDER
This form shall be posted on the 'ob with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work
on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance
of building oermit. For each applicable trade, all information requested below must be compieted by applicant. "On File" is not an acceptable response.
Trade. l: Class Cation
Contactor
State. C:pnttacvr.'s.-License.-:
W:orkers.: Campes�sation.lrsurance.. City Business License
--- -
-.:..
Company Name
Classification
(e.g. A, B, C-8)
License Number
(xxxxxx)
Exp. Date
(xx/xx/xx)
Carrier Name
(e.g. State Fund, CalComp)
Policy Number Exp. Date License Number
(Format Varies)(xx/xx/xx) (xxxx)
Exp. Date
(xx/xx/xx)
A THWORK (C-12)
fc � ►'
t 1
L GaoS
'5311,
,S
3101 %
dI�iCRETE'(:C-.8)
�JJ
,N G d C -SI. - ...
Wx�
STRU CT.. STEEL .:[G�15:'[ 1.
MASONRY (C-29)
'PLUMBING (C -3.C)
LATH, PLASTER: (C-351
DRYWALL (C-9)
VAG (C-2.0)
LECTRICAL (C=M.
ROOFING (G. 3.9): ...
S HET:METAL (C43) .- ..
FLOORING (CA 5.).
GLAZING (.0-17) .: . ..,
INSULATION .(C_-2)
SEWAGE DISP. {C -42•i
PA.INTkNG (:C-33.)
CERAMIC TILE (.0-54.)
CABINETS (C: -sl:
FFNC.ING :(C:-1.3)
LAN D:S.CAP1 NG:,(.0-27 ).
P4U.4..(C-53}
BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
Lennox/Vasilopoulos Residence
77-660 Calle Potrero
La Quinta, CA 92253 oypIck
Project Design
Rios Designs
49-901 Cinnabar LE
Coachella , Ca 922
760-485-7431
CITY OF LA C_UINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
ATE L,BY
_5U% 20I — 00
Report Prepared by:
Joan Hacker
Insu-form, Inc.
43585 Monterey Avenue, Suite 7 RECEIVED
Palm Desert, Ca 92260
760-345-1352 MAR 0 7 2019 C�
V-4TERWE•ST
BUILDING CODE COMPLIANCE REVIEW CONSULTING GROUP
THIS SET OF PLANS AND SPECIFICATIONS HAVE
BEEN REVIEWED FOR COMPLIANCE WITH THE
—
LOCALLY -ADOPTED CODES RELATED TO THIS
PROJECT'S STATED SCOPE OF WORK.
BY: DATE: � `1 �Ie
INTERWEST CONSULTING GROUPv r:
Date: `
2/15/2019""
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software – www.energysoft.com.
SND
TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF -1 R -PRF -01-E Certificate of Compliance 3
Form RMS -1 Residential Measures Summary 11
Form MF -1 R Mandatory Measures Summary 12
HVAC System Heating and Cooling Loads Summary 16
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 14:35, Fri, Feb 15, 2019
Calculation Description: Title 24 Analysis
Input File Name: Lennox_Vasilopoulos Residence.ribd16x
CF1 R -PRF -01
Page 1 of 8
GENERAL INFORMATION
01
Project Name Single Family Residence
02
Calculation Description Title 24 Analysis
03
Project Location 77-660 Calle Potrero
04
City La Quinta 05
Standards Version
Compliance 2017
06
Zip Code 92253 07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone CZ15 09
Software Version
EnergyPro 7.2
10
Building Type Single Family 11
Front Orientation (deg/Cardinal)
180
12
Project Scope Newly Constructed 13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft) 1779 15
Number of Zones
1
16
Slab Area (ft2) 1779 17
Number of Stories
1
18
Addition Cond. Floor Area(ft2) n/a 19
Natural Gas Available
No
20
Addition Slab Area (ft2) n/a 21
Glazing Percentage(%)
26.4%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
Registration Number: 419-P010020242A-000-000-0000000-0000 Registration Date/Time: 03/04/2019 12:59 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-15 14.35:31
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
2.66
4.75
-2.09
-78.6%
Space Cooling
101.18
100.58
0.60
0.6%
IAQ Ventilation
1.24
1.24
0.00
0.0%
Water Heating
13.79
12.21
1.56
11.5%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
118.87
118.78
0.09
0.1%
Registration Number: 419-P010020242A-000-000-0000000-0000 Registration Date/Time: 03/04/2019 12:59 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-15 14.35:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence
Calculation Description: Title 24 Analysis
Calculation DatelTime: 14:35, Fri, Feb 15, 2019
Input File Name: Lennox_Vasilopoulos Residence.ribd16x
CFI R -PRF -01
Page 2 of S
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency EDR of Proposed Efficiency
EDR Value of Proposed PV + Battery Final Proposed EDR
54.5 54.5
0.0 54.5
❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on-site photovoltaic (PV)
El
renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified.
Notes:
• Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering NEM rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
• --None --
Registration Number: 419-P010020242A-000-000-0000000-0000 Registration Date/Time: 03/04/2019 12:59 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-15 14:35:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 14:35, Fri, Feb 15, 2019
Calculation Description: Title 24 Analysis
Input File Name: Lennox_Vasilopoulos Residence.ribd16x
CFI R -PRF -01
Page 3 of 8
BUILDING - FEATURES INFORMATION
01
02
03
04
I 05
06
07
Project Name
Conditioned Floor Area (ftZ)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Single Family Residence
1779
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ftZ)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Whole House
Conditioned
Whole House1
1779
10
DHW Sys 1
n/a
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ftZ)
Window & Door Area (ftZ)
Tilt (deg)
Front Wall
Whole House
R-21 Wall
180
Front
400
174.068
90
Left Wall
Whole House
R-21 Wall
270
Left
380
26.4999
90
Rear Wall
Whole House
R-21 Wall
0
Back
400
77
90
Right Wall
Whole House
R-21 Wall
90
Right
300
60
90
Right Wall 2
Whole House
R-21 Wall
135
specify -
300
131.505
90
Roof
Whole House
R-38 Roof
n/a
n/a
1779
n/a
n/a
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Whole House Attic RoofWhole House Ventilated 0 0.1 0.85 Yes No
Registration Number: 419-P010020242A-000-000-0000000-0000 Registration Date/Time: 03/04/2019 12:59 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-15 14:35:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 14:35, Fri, Feb 15, 2019
Calculation Description: Title 24 Analysis
Input File Name: Lennox_Vasilopoulos Residence.ribd16x
CFI R -PRF -01
Page 4 of 8
FENESTRATION 1 GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
U -factor
SHGC
Exterior Shading
Window
Window
Front Wall (Front -180)
8.0
8.0
1
64.0
0.40
0.26
Insect Screen (default)
Window 2
Window
Front Wall (Front -180)
8.0
3.5
0.821
23.0
0.40
0.26
Insect Screen (default)
Window 3
Window
Front Wall (Front -180)
6.0
7.0
1.071
45.0
0.40
0.26
insect Screen (default)
Window 4
Window
Front Wall (Front -180)
6.0
1.1
1.227
8.1
0.40
0.26
Insect Screen (default)
Window 5
Window
Front Wall (Front -180)
4.0
4.5
1
18.0
0.40
0.26
Insect Screen (default)
Window 6
Window
Front Wall (Front -180)
1.0
8.0
1
8.0
0.40
0.26
Insect Screen (default)
Window 7
Window
Front Wall (Front -180)
1.0
8.0
1
8.0
0.40
0.26
Insect Screen (default)
Window 8
Window
Left Wall (Left -270)
3.0
8.0
1
24.0
0.40
0.26
Insect Screen (default)
Window 9
Window
Left Wall (Left -270)
3.0
.1
8.333
2.5
0.40
0.26
Insect Screen (default)
Window 10
Window
Rear Wall (Back -0)
----
----
1
8.0
0.40
0.26
Insect Screen (default)
Window 11
Window
Rear Wall (Back -0)
----
----
1
25.0
0.40
0.26
Insect Screen (default)
Window 12
Window
Rear Wall (Back -0)
--
--
1
20.0
0.47
0.24
insect Screen (default)
Window 13
Window
Rear Wall (Back -0)
--
---
1
12.0
0.40
0.26
Insect Screen (default)
Window 14
Window
Rear Wall (Back -0)
--
- -
1
12.0
0.40
0.26
Insect Screen (default)
Window 15
Window
Right Wall (Right -90)
----
--
1
20.0
0.40
0.26
Insect Screen (default)
Window 16
Window
Right Wall (Right -90)
---
----
1
10.0
0.40
0.26
Insect Screen (default)
Window 17
Window
Right Wall (Right -90)
- -
1
20.0
0.40
0.26
Insect Screen (default)
Window 18
Window
Right Wall (Right -90)
----
----
1
10.0
0.40
0.26
Insect Screen (default)
Window 19
Window
Right Wall 2 (- specify --135)
6.0
2.0
2
24.0
0.40
0.26
Insect Screen (default)
Window 20
Window
Right Wall 2 (- specify -135)
12.0
8.0
1
96.0
0.40
0.26
Insect Screen (default)
Window 21
Window
Right Wall 2 (- specify --135)
5.9
2.0
0.975
11.5
0.40
0.26
Insect Screen (default)
Registration Number: 419-P010020242A-000-000-0000000-0000 Registration Date/Time: 03/04/2019 12:59 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-15 14:35:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 14:35, Fri, Feb 15, 2019
Calculation Description: Title 24 Analysis
Input File Name: Lennox_Vasilopoulos Residence.ribd16x
CFI R -PRF -01
Page 5 of 8
OVERHANGS AND FINS
01
02
03
04
05
06
07
Area (ft2)
Perimeter (ft)
Edge Insul. R -value & Depth
Carpeted Fraction
Total Cavity
01
02
03
04
05
06
07
08
09
10
11
12 13
14
• Cavity/ Frame: no insul. /2x4 Top Chrd
Overhang
2x4 Top Chord of Roof Truss @ 24
Left Fin
Roof Deck: Wood Siding/sheathing/decking
Attic RoofWhole House
Right Fin
Wood Framed Ceiling
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up Dist R
Bot Up
Window
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 2
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 3
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 4
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 5
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 6
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 7
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 8
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 9
2
0.1
2
2
0
0
0
0
D
0
0 0
0
Window 19
8
0.1
8
8
0
0
0
0
0
0
0 0
0
Window 20
10
0.1
10
10
0
0
0
0
0
0
0 0
0
Window 2110
0.1
10
10
0
0
0
0
0
0
0 0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Area (ft2)
Perimeter (ft)
Edge Insul. R -value & Depth
Carpeted Fraction
Total Cavity
Winter Design
1779
Construction Name
Surface Type
Construction Type
Framing
R -value
U -f actor
Assembly Layers
• Cavity/ Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofWhole House
Attic Roofs
Wood Framed Ceiling
in. O.C.
none 1
0.644
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
R 19 in 5-1/2 in.
Cavity/Frame: R-19 in 5-1/2 in. (R-18) /2x6
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
cavity (R-18)
0.074
Exterior Finish: 3 Coat Stucco
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R -29.2/2x12
R-38 Roof
attic)
Wood Framed Ceiling
2x12 @ 16 in. O.C.
R38
0.027
Over Ceiling Joists: R-8.8 insul.
SLAB FLOORS
01 02
03
04
05
06
07
Name Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R -value & Depth
Carpeted Fraction
Heated
Slab -on -Grade Whole House
1779
485
None
1
No
Registration Number: 419-P010020242A-000-000-0000000-0000 Registration DateMme: 03/04/2019 12:59 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-02-15 14:35:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 14:35, Fri, Feb 15, 2019
Calculation Description: Title 24 Analysis
Input File Name: Lennox_Vasilopoulos Residence.ribd16x
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required n/a
CFI R -PRF -01
Page 6 of 8
WATER HEATING SYSTEMS
01 02
03 04 05
06
Name System Type
Distribution Type Water Heater Number of Heaters
Solar Fraction (%)
DHW Sys 1 DHW
Standard DHW Heater 1 (1) 1
0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Name
System Type
Number of Units
EER SEER
Input Rating I
Tank
Standby
Cooling Component 1
SplitAirCond
1
13
Heater
Not Zonal
Single Speed
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
NEEA Heat Pump
Tank Location
1 -hers -cool
Element
Number
Volume
Factor / Energy
Thermal
R -value
Recovery
Rating /
Brand / Model /
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Other
Condition
DHW Heater 1
Gas
Small Storage
1
50
0.98 EF
<= 75 kBtu/hr
R -0/R-0
0
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
01
02 03 04 05 06
SC Sys Name
System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name
Whole Housel
Other Heating and Cooling Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1
System
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Efficiency
Heating Component 1 CntrlFurnace 1 80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04 05
06
07
08
Efficiency
Name
System Type
Number of Units
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
1
13
F 16
Not Zonal
Single Speed
Cooling Component
1 -hers -cool
Registration Number: 419-P010020242A-000-000-0000000-0000 Registration DateMme: 03/04/2019 12:59
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149
HERS Provider: CHEERS
Report Generated at: 2019-02-15 14:35:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 14:35, Fri, Feb 15, 2019
Calculation Description: Title 24 Analysis
Input File Name: Lennox_Vasilopoulos Residence. ribd 1 6x
CFI R -PRF -01
Page 7 of 8
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01 02
03 04
05 06
07
Name Type
Duct Leakage Insulation R -value
Duct Location Bypass Duct
HERS Verification
Air Distribution System 1 DuctsAttic
Sealed and tested 8
Attic None
Air Distribution System
1 -hers -dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1 -hers -dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
HVAC -FAN SYSTEMS
01
02 03 04
Name
Type Fan Power (Watts/CFM) HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02
03
Name Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
48
0.25
Default
0
Required
Registration Number: 419-P010020242A-000-000-0000000-0000 Registration Date/Time: 03/04/2019 12:59 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-15 14:35:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation Date/Time: 14:35, Fri, Feb 15, 2019
Calculation Description: Title 24 Analysis
Input File Name: Lennox_Vasilopoulos Residence.ribd16x
CF1 R -PRF -01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Joan Hacker
JOGN T(acJ`ex
Company:
Signature Date:
Joan Hacker
03/04/2019
Address:
CEA/HERS Certification Identification (If applicable):
72875 Fred Waring Drive
City/State/Zip:
Phone:
Palm Desert, CA 92260
760-345-1352
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Gabriel Rios
G"'f"-CeZ7?C k
Company:
Date Signed:
Rios Designs
03/04/2019
Address:
License:
49-901 Cinnabar Lane
City/State/Zip:
Phone:
Coachella, CA 92236
760-485-7431
Digitally signed by CHEERS"*% This digital signature is provided in order to secure the content of this registered
document and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 419-P010020242A-000-000-0000000-0000 Registration DatelTime: 03/04/2019 12:59 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-02-15 14:35:31
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Lennox/Vasilopoulos Residence
Building Type 17 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
2115/2019
Project Address
77-660 Calle Potrero La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
1,779
Addition
n/a
# of units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features Status
Wall Wood Framed R 19 in 5-1/2 ii 1,311 New
Slab Unheated Slab -on -Grade - no insulation 1, 779 Perim = 485' New
Roof Wood Framed Attic R 38 1,779 New
FENESTRATION I Total Area: 469 Glazing Percentage: 26.4% 1 NeWAltered Avera a u -Factor. 0.40
Orientation Area(ft2) U -Fac SHGC Overhang Sidefins Exterior Shades Status
Front (S) 174.1 0.400
0.26 2.0 none Bug Screen New
Left (IM 26.5 0.400
0.26 2.0 none Bug Screen New
Rear (N) 57.0 0.400
0.26 none none Bug Screen New
Rear (N) 20.0 0.470
0.24 none none Bug Screen
New
Right (E) 60.0 0.400
0.26 none none Bug Screen
New
Right (SE) 24.0 0.400
0.26 8.0 none Bug Screen
New
Right (SE) 107.5 0.400
0.26 10.0 none Bug Screen
New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 16.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
Whole House Ducted
Ducted Attic 8.0
New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
1 Small Storage Gas 50
0.98 Standard
New
Ener Pro 7.2 by Ener Soft User Number: 2655
1D:
Pae 11 of 16
, n",;' '6
~i-" 2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. 'Exceptions may apply.
!Revised 04/20171
Building Envelope Measures:
§ 110.6(a)l
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per
NFRC-400 or ASTM E283 or AAMAIWDMAICSA I0111.S.21A440-2011
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use LI -factors and solar heat gain coefficient (SHGC) values from TABLES
110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.'
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 110.8(i) when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0,05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U -factor must not exceed 0.043.
Minimum R-19 or weighted average U -factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceiling.'
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R -value.
Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a LI -factor of 0.102 or less (R-19 in 2x6 or U-
§ 150.0(c):
factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U -factor not exceeding 0.102, equivalent to an installed
value of R-13 in a wood framed assembly.*
§ 150,0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U -factor.'
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 permfinch; be protected from physical damage and UV light
deterioration: and, when installed as part of a heated slab floor. meet the requirements of § 110.8( ).
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
1 50,0 1
§ (g)
requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d).
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
§ 150.0(g)2:
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U -factor of 0.58; or the weighted avers a Ll -factor of all fenestration must not exceed 0.58.`
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)1A:
Closable Doors. Masonry orfactory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)l B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight-fittinq damper or combustion -air control device.'
§ 150.0(e)1 C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission'
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.'
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)5.
§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
§ 110.5:
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool and spa heaters.`
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)1:
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions specified in § 150.0(h)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
dryer vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacture's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.*
§ 150,00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve.'
§ 150.00)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.0(j)2A. Distribution
piping for steam and hyrdronic heating systems or hot water systems must meet the requirements in TABLE 120.3-A.'
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.00)36:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)1:
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
y of at least 200,000 Btu/hr.
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacit
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation (SRCC) or by a listing agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certV to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)l:
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/. inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross-sectional area of the ducts:
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tae is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manuals operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with 150.0 m 11 and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of § 150.0(m)12.
4 1 2016 Low -Rise Residential Mandato Measures Summa
� r11 rY
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy 5 0.58 WlCFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced airs stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(0):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
§ 150.0(o)1A:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testin , in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating!
§ 110.4(b)1:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines. or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run onIv during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
§ 150.0(p):
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, piping, filters, and valves'
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
Of § 110.9'
§ 110.9(e):
JA8 High Efficacy Light Sources. To qualify as a JAS high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1 C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)1 D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors.
§ 150.0(k)1 F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the a0olicable requirements of § 150.0(k).*
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1G:
with Reference Joint Appendix JA8. Installed lamps must be marked with `JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8.'
§ 150.0(k)1 H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JAS compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5(8: and meets all other requirements in b 150.0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5(8; and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in 6 150.0(k)2.
X_' '1�
r 2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)21
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JAS, except luminaires in closets less than 70 square feet and luminaires in hallwa s.'
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS).
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either 6150.0(k)3A or with the applicable requirements in 110.9, 130.0, 130.2. 130.4, 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0(k)3B or§ 150.0(k)3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must comply with the applicable requirements in §4110.9,130.0, 130.2 130.4 140.7 and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
.
Dower as determined according to § 130.Wc).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
aoDlicable reouirements for nonresidential garages in §§ 110.9, 130.0. 130.1. 130.4. 140.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor,
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occu ant sensors must be capable of turning the liqht fully on and off from all desi ned paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of 110.10 b through § 110.10 e .
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 Dercent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.'
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical lane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearlv indicated on the construction documents.
Interconnection Pathways, The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.1 0 c must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Lennox/Vasilopoulos Residence
Date
2/15/2019
System Name
Whole House
Floor Area
1,779
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING PEAK
CFM Sensible
Total Room Loads 910 21,729
Return Vented Lighting 0
Return Air Ducts 1,254
Return Fan 0
Ventilation 0 0
Supply Fan 0
Supply Air Ducts 1,254
TOTAL SYSTEM LOAD] 1 24,238
COIL HTG,
PEAK
Heating System
Latent
CFM
Sensible
Output perSystem 86,000
1,758
926
33,754
Total Output Btuh 86,000
Output Btuh/s ft 48.3
1,659
Cooling System
0
Output perSystem
58,000
0
0
0
Total Output Btuh
58,000
1,758
0
Total Output Tons
4.8
1,659
Total Output Btuhls ft
32.6
Total Output s ftlTon
368.1
37,072
Air System
CFM perS tem
2,055
HVAC EQUIPMENT SELECTION
Airflow cfm
2,055
York GCGD 60S 415 3A 44,093
5,589
86,000
Airflow cfmis ft
1.16
Total Adjusted System Output 44,093
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
5,589 86,000
Aug 3 PM Jan 1 AM
Airflow cfm/Ton
425.2
Outside Air %
0.0%
Outside Air cfm/s ft
0.00
Note: values above giVen at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak)
26 IF 69 IF 69 IF
Outside Air
0 cfm Supply Fan Heating Coil
2,055 cfm
69 OF
104 IF
ROOM -v6
70 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak
1? 178 OF 63
Outside Air
0 cfm
79 / 63 OF
°[ 79 / 63 OF 55 154 OF
I
Supply Fan Cooling Coil 56 / 54 IF
2,055 cfm
42.0% ROOM
1.
78163 63