BRES2019-0084T4'v 4 .fwQu,,�Krw
78-495 CALLE TAMPICO
VOICE (760) 777-7125
LA QUINTA, CALIFORNIA
92253
FAX (760) 777-7011
DESIGN &DEVELOPMENT DEPARTMENT
INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 4/24/2019
Permit Type/Subtype:
BUILDING RESIDENTIAL/ADDITION
Owner:
Application Number:
BRES2019-0084
THIS IS HOW WE DO IT LLC
Property Address:
53308 ROSS AVE
53308 ROSS AVENUE
APN:
Application Description:
767680012
THIS IS HOW WE DO
IT, LLC. / 76 S.F. GARAGE ADDITION
LA QUINTA, CA 92253
Property Zoning:
Application Valuation:
$1,400.00
Applicant:
Contractor:
HUGO CERVANTES
°
DISCOVERY BUILDERS CALIFORNIA INC DBA DB
LA QUINTA, CA 92253
orf 4 �0+.
# I
14605 N 73RD STREET
SCOTTSDALE, AZ 85260
'NTA
(480)624-5200
DESIGN & DEVELUM"VIEN I AMR, j
Llc. No.: 915336
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
(commencing with Section 70001 of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: B License No.: 015336--
` Contr;.actora .
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law For the following reason (Sec. 703 1.5, Business and Professions Code. Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to Its issuance, also requires the applicant for the permit to file a signed
statement that he a she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code] or that he a she is exempt therefrom and the basis for the
alleged exemp[ian. Any violation of Section 7031..5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_,) I, as owner of the property, a my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Prafesslons Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does Che work
himself a herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement Is sola
within one year of completion, the owner -bull will }lave the burden of proving that he APPLICANT ACKNOWLEDGEMENT
Or she did not build or improve far the purpose of sale.). IMPORTANT: Application is hereby.made to the Building Official for a permit subject to
L) I, as owner of the property, am extluslvely contract Ing with licensed contractors to the conditions and restrictions set forth on this application.
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State 1. Each person upon whose behalf this application is made, each person at whose
License Law does not apply 10 an owner of property who builds or improves thereon, request and for whose benefit work is performed under or pursuant to any permit issued
and who contracts for the projects with a contractors) licensed pursuant to the as a result of this application , the owner, and the applicant, each agrees to, and shall
Contractors' State License Law.). defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
(_) I am exempt under Sec. B.&P.C. for this reason employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Sectlan 3700 of the Labor Code, for the performance
of th ark f
ar which this permit is sissued.
' ' ave and will maintain workers' compensation insurance, as required.by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are.
Carrier TRAVELERS PRQEFRTY CAS JALTY COMPANY OF Policy Number.
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 a bar Code, I shall forthwith
comply with those provisions.
bate: U-20Applicant"— —�-
WARNING: FAILURE TO SECURE WO RS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER O CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
Date:
Owner
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Add
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city toe ` up n the above-
mentioned property for inspection purposes.
Date: 2 • C) Signatuher(Applicant or Agent
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
Applicant:
HUGO CERVANTES
LA QUINTA, CA 92253
BRES2019-0084
53308 ROSS AVE
767680012
THIS IS HOW WE DO IT, LLC. / 76 S.F. GARAGE ADDITION
$1,400.00
Date: 4/24/2019
Owner:
THIS IS HOW WE DO IT LLC
53308 ROSS AVENUE
LA QUINTA, CA 92253
Contractor:
DISCOVERY BUILDERS CALIFORNIA INC DBA DB
14605 N 73RD STREET
SCOTTSDALE, AZ 85260
(480)624-5200
Llc. No.: 915336
Detail: REVISION TO PLANS FOR SINGLE FAMILY DWELLING CURE MY -LY UNDtlk tO,NSTRUCTION--REFERENCE SFD PERMIT BRES2018-0422. ADD 76
ADDITIONAL SQUARE FEET AT GARAGE + NEW WINDOW NEAR ENTRY HALL. DOES NOT INCLUDE INSTALLATION OF FIREPLACE. 2016 CODES.
Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $103.90
FINANCIAL
DESCRIPTION
ACCOUNT QTY AMOUNT
PLAN CHECK DEPOSIT - ADDITION/REMODEL
101-0000-42600 1 $125.00
Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RECORDS MANAGEMENT FEE - MAJOR
101-0000-42416
0
$21.00
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
101-0000-42600
($0.50)
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$0.50
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
101-0000-42600
($17.77)
DESCRIPTION
ACCOUNT
QTY
AMOUNT
101-0000-42600
($106.73)
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DOOR/WINDOW, NEW/ALT, FIRST 1
101-0000-42400
0
$106.73
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DOOR/WINDOW, NEW/ALT, FIRST 1 PC
101-0000-42600
0
$17.77
DESCRIPTION
ACCOUNTQTY
AMOUNT
DOOR/WINDOW, NEW/ALT, FIRST 1 PC
101-0000-42600
0
$103.90
Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $103.90
acaQigra
Project Address:
A P N #: '7I T - i/q4' -,0,q C/
IT # 1dYE3 r3rJIC1'
PLAN LOCATION -
Project Description: 3�
Da,FD J7c��dNJ C,
42U riCY 7lJ J
FWN
Applicant Name: r�G `" ^►I y'JJ��l�� S A16OU 01 -1451s -JA [+
Address:
M
City,ST Zi 1 Gcy�4ci��� f
Telephone: A&Wm / j )
Email:A(rrvaii (Q Valuation of Project $
Contractor Name: New SFD Construction:
Address: Conditioned Space SF
City, St, Zip Garage f7 ! SF
Telephone: Patio/Porch SF
Email: Fire Sprinklers SF
State Lic: City Bus Lic:
Architect/ Engineer Name: V
Address: -" �
City, St, Zip
Telephone:
Email:
State Lic: City Bus Lic:
Property Owner's Name:
Address:
City, ST, ip'
D a L
Telephone:
Email:
' Construction
Grading:
Bedrooms: I Stories:
Occupancy: I
# Units:
New Commercial / Tenant Improvements:
Total Building SF
Construction Type: Occupancy:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
OFFICE USE ONLY
#� Submittal Required Received
Plan Sets
�
structural Calcs
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
1 City Business License
! BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Lot 50 Madison Club
53-308 Ross Ave.
La Quinta, CA 92253
Project Designer:
HC Design
51825 Avenida Volosco
La Quinta, CA 92253
7607995244
Report Prepared by:
Jon d. Scott
Scott Design and Title 24, Inc,
74818 Velie Way Suite 8
Palm Desert, CA 92260�7-Y OF LA QCJINTA
(760) 200-4780 BUILDING DIVISION
REVIEWED FOA
CODE
COMPLIANCE
Job Number: O Ce 55T
ptl
Date: APR 12 2019
4/12/2019 14
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
'..
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF -1 R -PRF -01-E Certificate of Compliance
Form RMS -1 Residential Measures Summary
1
2
3
16
Form MF -1 R Mandatory Measures Summary 18
CERTI' TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: 53-308 Ross Ave.
Calculation Description: Title 24 Analysis
■ o -
Calculation Date/Time: 12:54, Fri, Apr 12, 2019
Input File Name: Madison Lot 50-Hugo-18.dbd16x
CF 'RF -01
Page 1 of 13
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name 53-308 Ross Ave.
04
05
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location 53-308 Ross Ave.
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2017
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone CZ15
09
Software Version EnergyPro 7.2
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 180
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ftZ) 10326
15
Number of Zones 6
16
Slab Area (ftZ) 10326
17
Number of Stories 1
18
Addition Cond. Floor Area(ft2) n/a
19
Natural Gas Available Yes
20
Addition Slab Area (ft), n/a
21
Glazing Percentage (%) 14.5%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
Registration Number: 218-P010334437D-000-000-0000000-0000 Registration DateMme: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-011 62 01 9-11 49 Report Generated at: 2019-04-12 12:55:29
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
1.32
2.21
-0.89
-67.4%
Space Cooling
IAQ Ventilation
67.18
1.09
61.37
1.09
5.81
0.00
8.6%
0.0%
Water Heating
1.59
1.38
0.21
13.2%
Photovoltaic Offset
---
0.00
0.00
—
Compliance Energy Total
71.18
66.05
5.13
7.2%
Registration Number: 218-P010334437D-000-000-0000000-0000 Registration DateMme: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-011 62 01 9-11 49 Report Generated at: 2019-04-12 12:55:29
CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE HOD CF 'RF -01
Project Name: 53-308 Ross Ave.
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:54, Fri, Apr 12, 2019
Input File Name: Madison Lot 50-Hugo-18.ribd16x
Page 2 of 13
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 247 Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency
EDR of Proposed Efficiency
EDR Value of Proposed PV + Battery
Final Proposed EDR
47.8
45.2
0.0
45.2
❑ Design meets Tier 1 requirement of 15°/a or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
Q Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on-site photovoltaic (PV)
renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified.
Notes:
• Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Central parallel piping —
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
•
Minimum Airflow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
• -- None --
Registration Number: 218-Po10334437D-000-000-0000000-0000 Registration Date/Time: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29
CERTI' TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: 53-308 Ross Ave.
Calculation Description: Title 24 Analysis
HOD
Calculation Date/Time: 12:54, Fri, Apr 12, 2019
Input File Name: Madison Lot 50-Hugo-18.ribdl6x
CF 'RF -01
Page 3 of 13
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
53-308 Ross Ave.
10326
1
18
6
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
gym
Conditioned
HVACgym1
1252
9
DHW Sys 1
n/a
pickle
Conditioned
HVACpic2
2599
9
DHW Sys 1
n/a
Lounge
Conditioned
HVACsport3
2375
9
DHW Sys 1
n/a
living kitchen hall
Conditioned
HVACIiv4
2200
9
DHW Sys 1
n/a
master
Conditioned
HVACmstr5
1000
9
DHW Sys 1
n/a
Bedroom
Conditioned
HVACbed6
900
9
DHW Sys 1
n/a
Registration Number: 218-Po10334437D-000-000-0000000-0000 Registration Dateffime: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29
CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: 53-308 Ross Ave.
Calculation Description: Title 24 Analysis
.
We
Calculation Date/Time: 12:54, Fri, Apr 12, 2019
Input File Name: Madison Lot 50-Hugo-18.ribdl6x
CF 3RF-01
Page 4 of 13
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
N Wall
gym
R-21 Wall
0
Back
1020
504
90
E Wall
gym
R-21 Wall
90
Right
375
0
90
S Wall
gym
R-21 Wall
180
Front
125
0
90
W Wall
gym
R-21 Wall
270
Left
375
0
90
Interior Surface
gym
R-0 Interior Wall
n/a
n/a
566
0
n/a
RoofR38R13gym
gym
R-38 Roof Attic
n/a
n/a
1252
n/a
n/a
E Wall 2
pickle
R-21 Wall
90
Right
580
0
90
W Wall 2
pickle
R-21 Wall
270
Left
580
0
90
Interior Surface 2
pickle
R-0 Interior Wall
n/a
n/a
566
0
n/a
Interior Surface 3
pickle
R-0 Interior Wall
n/a
n/a
566
0
n/a
Interior Surface 4
pickle
R-0 Interior Wall
n/a
Na
566
0
n/a
Interior Surface 5
pickle
R-0 Interior Wall
n/a
n/a
566
0
n/a
Interior Surface 6
pickle
R-0 Interior Wall
n/a
n/a
566
0
n/a
Interior Surface 7
pickle
R-0 Interior Wall
n/a
n/a
566
0
n/a
RoofR38R13pic
pickle
R-38 Roof Attic
n/a
n/a
2599
n/a
n/a
E Wall 3
Lounge
R-21 Wall
90
Right
980
0
90
S Wall 2
Lounge
R-21 Wall
180
Front
1052
180
90
W Wall 3
Lounge
R-21 Wall
270
Left
620
0
90
Interior Surface 8
Lounge
R-0 Interior Wall
n/a
n/a
566
0
n/a
RoofR38R13sport
Lounge
R-38 Roof Attic
n/a
n/a
2375
n/a
n/a
N Wall 2
living kitchen hall
R-21 Wall
0
Back
560
272.4
90
E Wall 4
living kitchen hall
R-21 Wall
90
Right
380
0
90
S Wall 3
living kitchen hall
R-21 Wall
180
Front
300
159
90
W Wall 4
living kitchen hall
R-21 Wall
270
Left
560
0
90
Interior Surface 9
living kitchen hall
R-0 Interior Wall
n/a
n/a
412
0
n/a
RoofR38R13liv
living kitchen hall
R-38 Roof Attic
n/a
n/a
2200
Na
n/a
W Wall 5
master
R-21 Wall
270
Left
540
209
90
Interior Surface 10
master
R-0 Interior Wall
n/a
n/a
288
0
n/a
Interior Surface 11
master
R-0 Interior Wall
n/a
n/a
288
0
n/a
Interior Surface 12
master
R-0 Interior Wall
n/a
n/a
288
0
n/a
Registration Number: 218-P010334437D-000-000-0000000-0000 Registration Dateff-ime: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29
CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE HOD CF 'RF -01
Project Name: 53-308 Ross Ave.
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:54, Fri, Apr 12, 2019
Input File Name: Madison Lot 50 -Hugo -1 8.ribdl 6x
Page 5 of 13
Interior Surface 13
master
R-0 Interior Wall
n/a
n/a
288
0
n/a
Interior Surface 14
master
R-0 Interior Wall
n/a
n/a
288
0
n/a
Interior Surface 15
master
R-0 Interior Wall
n/a
n/a
288
0
n/a
Roofr38R13mstr
master
R-38 Roof Attic
n/a
n/a
1000
n/a
n/a
W Wall 6
Bedroom
R-21 Wall
270
Left
380
200
90
Interior Surface 16
Bedroom
R-0 Interior Wall
n/a
n/a
288
0
n/a
Interior Surface 17
Bedroom
R-0 Interior Wall
n/a
n/a
288
0
n/a
Interior Surface 18
Bedroom
R-0 Interior Wall
n/a
n/a
288
0
n/a
Interior Surface 19
Bedroom
R-0 Interior Wall
n/a
n/a
288
0
n/a
Interior Surface 20
Bedroom
R-0 Interior Wall
n/a
n/a
288
0
n/a
Interior Surface 21
Bedroom
R-0 Interior Wall
n/a
n/a
288
0
n/a
Roofr38R13bed
Bedroom
R-38 Roof Attic
i n/a
n/a
900
n/a
n/a
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic gym
Attic Roofgym
Ventilated
0
0.1
0.85
No
No
Attic pickle
Attic Roofpickle
Ventilated
0
1 0.1
0.85
No
No
Attic Lounge
Attic Roofl-ounge
Ventilated
0
0.1
0.85
No
No
Attic living kitchen hall
Attic Roofliving kitchen hall
Ventilated
0
0.1
0.85
No
No
Attic master
Attic Roofmaster
Ventilated
0
0.1
0.85
No
No
Attic Bedroom
Attic RoofBedroom
Ventilated
0
0.1
0.85
No
No
Registration Number: 218-P010334437D-000-000-0000000-0000 Registration Dateff-ime: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29
CERTG TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE HOD CF 'RF -01
Project Name: 53-308 Ross Ave. Calculation DatelTime: 12:54, Fri, Apr 12, 2019 Page 6 of 13
Calculation Description: Title 24 Analysis Input File Name: Madison Lot 50-Hugo-18.ribdl6x
FENESTRATION / GLAZING
01
02
03
04
05 06
07
08
09
10
Height
Area
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
(ft) Multiplier
(ftZ)
U -factor
SHGC
Exterior Shading
42x12
Window
N Wall (Back -0)
-
1
504.0
0.42
0.21
Insect Screen (default)
15x12
Window
S Wall 2 (Front -180)
----
-- 1
180.0
0.42
0.21
Insect Screen (default)
22.2x12
Window
N Wall 2 (Back -0)
-
1
272.4
0.42
0.21
Insect Screen (default)
5x10
Window
S Wall 3 (Front -180)
-
- 1
60.0
0.42
0.21
Insect Screen (default)
7.5x10
Window
S Wall 3 (Front -180)
- 1
75.0
0.42
0.21
Insect Screen (default)
15x11
Window
W Wall 5 (Left -270)
-- 1
165.0
0.42
0.21
Insect Screen (default)
6x6
Window
W Wall 5 (Left -270)
--
- 1
36.0
0.42
0.21
Insect Screen (default)
4x2
Window
W Wall 5 (Left -270)
--
- 1
8.0
0.42
0.21
Insect Screen (default)
10x10
Window
W Wall 6 (Left -270)
-
1
100.0
0.42
0.21
Insect Screen (default)
10x10 2
Window
W Wall 6 (Left -270)
I-
- 1
100.0
0.42
0.21
Insect Screen (default)
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ftZ)
U -factor
Door
S Wall 3
24.0
0.50
Registration Number: e18-Poi0334437D-000-000-0000000-0000 Registration Date/Time: 2019-04-12 13:01:24 HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29
CERTI' TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: 53-308 Ross Ave.
Calculation Description: Title 24 Analysis
;-IOD
Calculation Date/Time: 12:54, Fri, Apr 12, 2019
Input File Name: Madison Lot 50-Hugo-18.ribdl6x
CF 'RF -01
Page 7 of 13
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -factor
Assembly Layers
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R-13.0 /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck.' Wood Siding/sheathing/decking
Attic Roofgym
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing. Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R-21 /2x6
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
• Cavity/Frame: no insul. /2x4
R-0 Interior Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.277
Other Side Finish: Gypsum Board
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R -13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofpickle
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing., Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R -13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofl-ounge
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing., Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R -13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofliving kitchen hall
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing., Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R -13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofmaster
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing. Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R-13.0 /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck. Wood Siding/sheathing/decking
Attic RoofBedroom
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing. Light Roof (Asphalt Shingle)
Registration Number: 218-Po10334437D-000-000-0000000-0000 Registration Date/Time: 2019-04-1213:01:24 HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29
CERTI ,TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: 53-308 Ross Ave.
Calculation Description: Title 24 Analysis
■6o
Calculation Date/Time: 12:54, Fri, Apr 12, 2019
Input File Name: Madison Lot 50-Hugo-18.ribd16x
Cl 'RF -01
Page 8 of 13
SLAB FLOORS
01
02
03
04
05
06
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R -value & Depth
Carpeted Fraction
Heated
Slab -on -Grade
gym
1252
115
None
0.8
No
Slab -on -Grade 2
pickle
2599
85
None
0.8
No
Slab -on -Grade 3
Lounge
2375
136
None
0.8
No
Slab -on -Grade 4
living kitchen hall
2200
56
None
0.8
No
Slab -on -Grade 5
master
1000
36
None
0.8
No
Slab -on -Grade 6
Bedroom
900
35
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required n/a
WATER HEATING SYSTEMS
01 02 03 04 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 DHW Central Parallel Piping DHW Heater 1 (2) 2 .0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Input Rating!
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
NEEA Heat Pump
Tank Location
Element
Number
Volume
Factor/ Energy
Thermal
R -value
Recovery
Rating I
Brand / Model /
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Other
Condition
DHW Heater 1
Gas
Small
Instantaneous
2
0
0.96 EF
<= 200 kBtu/hr
R -0/R-0
0
n/a
n/a
n/a
Registration Number: 218-Po10334437D-000-000-0000000-0000 Registration Date/Tme: 2019-04-12 13:01-24 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29
CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: 53-308 Ross Ave.
Calculation Description: Title 24 Analysis
■*a
Calculation Date/Time: 12:54, Fri, Apr 12, 2019
Input File Name: Madison Lot 50-Hugo-18.ribd16x
CF, 'RF -01
Page 9 of 13
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC m1
gy
Heat Pump Heating and
Cooling System
Heat Pump System 1
Heat Pump System 1
HVAC Fan 1
Air Distribution System 1
HVACpic2
Heat Pump Heating and
Cooling System
Heat Pump System 2
Heat Pump System 2
HVAC Fan 2
Air Distribution System 2
HVACs ort3
p
Heat Pump Heating and
Cooling System
Heat Pum p System 3
Heat Pum p System 3
HVAC Fan 3
Air Distribution System 3
HVACliv4
Heat Pump Heating and
Cooling System
Heat Pump System 4
Heat Pump System 4
HVAC Fan 4
Air Distribution System 4
HVACmstr5
Heat Pump Heating and
Cooling System
Heat Pump System 5
Heat Pump System 5
HVAC Fan 5
Air Distribution System 5
HVACbed6
Heat Pump Heating and
Cooling System
Heat Pump System 6
Heat Pump System 6
HVAC Fan 6
Air Distribution System 6
HVAC - HEAT PUMPS
01
02
03
04 05 06
07 1 08
09
10
11
Name
System
Type
Number of
Units
Heating
Cooling
Zonally
Controlled
Compressor
Type
HERS
Verification
HSPF/COP
Cap 47
Cap 17
SEER
EER
Heat Pump System 1
SplitHeatPump
1
8
55600
33360
16
12.5
Not Zonal
Single Speed
Heat Pump System
1 -hers -cool
Heat Pump System 2
SplitHeatPump
2
8
55600
33360
16
12.5
Not Zonal
Single Speed
Heat Pump System
2 -hers -cool
Heat Pump System 3
SplitHeatPump
1
8
55600
33360
16
12.5
Not Zonal
Single Speed
Heat Pump System
3 -hers -cool
Heat Pump System 4
SplitHeatPump
1
8
55600
33360
16
12.5
Not Zonal
Single Speed
Heat Pump System
4 -hers -cool
Heat Pump System 5
SplitHeatPump
1
8
12000
7200
16
12.5
Not Zonal
Single Speed
Heat Pump System
5 -hers -cool
Heat Pump System 6
SplitHeatPump
1
8
12000
7200
16
12.5
Not Zonal
Single Speed
Heat Pump System
6 -hers -cool
Registration Number: 218-P010334437D-000-000-0000000-0000 Registration Date/-l-ime: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29
CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE HOD CF" 'RF -01
Project Name: 53-308 Ross Ave. Calculation Date/Time: 12:54, Fri, Apr 12, 2019 Page 10 of 13
Calculation Description: Title 24 Analysis Input File Name: Madison Lot 50 -Hugo -1 8.ribdl 6x
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Heat Pump System 1 -hers -cool
Required
350
Required
Required
Required
Heat Pump System 2 -hers -cool
Required
350
Required
Required
Required
Heat Pump System 3 -hers -cool
Required
350
Required
Required
Required
Heat Pump System 4 -hers -cool
Required
350
Required
Required
Required
Heat Pump System 5 -hers -cool
Required
350
Required
Required
Required
Heat Pump System 6 -hers -cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R -value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
1 -hers -list
Air Distribution System 2
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
2 -hers -dist
Air Distribution System 3
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
3 -hers -dist
Air Distribution System 4
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
4 -hers -dist
Air Distribution System 5
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
5 -hers -dist
Air Distribution System 6
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
6 -hers -dist
Registration Number: 218-P010334437D-000-000-0000000-0000 Registration DateRme: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-01162019-1149 Report Generated at: 2019-04-12 12:55:29
CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: 53-308 Ross Ave.
Calculation Description: Title 24 Analysis
0901
Calculation Date/Time: 12:54, Fri, Apr 12, 2019
Input File Name: Madison Lot 50-Hugo-18.ribd16x
CF 'RF -01
Page 11 of 13
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1 -hers -dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
Air Distribution System 2 -hers -dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
Air Distribution System 3 -hers -dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
Air Distribution System 4 -hers -dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
Air Distribution System 5 -hers -dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
Air Distribution System 6 -hers -dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
HVAC -FAN SYSTEMS
01
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.54
HVAC Fan 1 -hers -fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.54
HVAC Fan 2 -hers -fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.54
HVAC Fan 3 -hers -fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.54
HVAC Fan 4 -hers -fan
HVAC Fan 5
Single Speed PSC Furnace Fan
0.54
HVAC Fan 5 -hers -fan
HVAC Fan 6
Single Speed PSC Furnace Fan
0.54
HVAC Fan 6 -hers -fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan
Required
0.54
HVAC Fan 2 -hers -fan
Required
0.54
HVAC Fan 3 -hers -fan
Required
0.54
HVAC Fan 4 -hers -fan
Required
0.54
HVAC Fan 5 -hers -fan
Required
0.54
HVAC Fan 6 -hers -fan
Required
0.54
Registration Number: 218-P010334437D-000-000-0000000-0000 Registration DateMme: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29
CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE HOD CF 'RF -01
Project Name: 53-308 Ross Ave. Calculation Date/Time: 12:54, Fri, Apr 12, 2019 Page 12 of 13
Calculation Description: Title 24 Analysis Input File Name: Madison Lot 50-Hugo-18.ribd16x
IAQ (Indoor Air Quality) FANS
01 02 03 04 05 06
IAQ Recovery
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type Effectiveness(%) HERS Verification
SFam IAQVentRpt 246 0.25 Default 0 Required
Registration Number: 218-P010334437D-000-000-0000000-0000 Registration Date/Time: 2019-04-12 13:01:24 HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-01162019-1149 Report Generated at: 2019-04-12 12:55:29
CERTII TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: 53-308 Ross Ave.
Calculation Description: Title 24 Analysis
40D
Calculation Date/Time: 12:54, Fri, Apr 12, 2019
Input File Name: Madison Lot 50-Hugo-18.ribdl6x
CF 'RF -01
Page 13 of 13
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2019-04-12 13:01:24
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature.
Gfir,Jff/
Tim Scott
Company:
Date Signed:
Scott Design and Title 24, Inc.
2019-04-12 13:01:24
Address:
License:
77085 Michigan Drive
na
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 218-P010334437D-000-000-0000000-0000 Registration Date/Tme: 2019-04-12 13:01:24
CA Building Energy Efficiency Standards - 2016 Residential Compliance ReportVersion - CFIR-01162019-1149
t
L
Easy to Verify
HERS Provider: CaICERTS inc.
Report Generated at: 2019-04-12 12:55:29
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Lot 50 Madison Club
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
4/12/2019
Project Address
53-308 Ross Ave. La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area Addition
10,326 n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features
Status
Roof Wood Framed Attic
R 38 10,326 Add=R-13.0
New
Wall Wood Framed
R 21 6,903
New
Slab Unheated Slab-on-Grade
no insulation 10,326 Perim = 463'
New
Demising Wood Framed
no insulation 8,396
New
Door Opaque Door
no insulation 24
New
FENESTRATION Total Area: 7.500 Glazing Percentage: 14.5% New/Altered Average U•Factor:
Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades
0.42
Status
Rear (N) 776.4 0.420
0.21 none none Bug Screen
New
Front (S) 315.0 0.420
0.21 none none Bug Screen
New
Left (W) 409.0 0.420
0.21 none none Bug Screen
New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Split Heat Pump 8.00 HSPF
Split Heat Pump 16.0 SEER Setback
New
2 Split Heat Pump 8.00 HSPF
Split Heat Pump 16.0 SEER Setback
New
1 Split Heat Pump 8.00 HSPF
HVAC DISTRIBUTION
Location Heating
Split Heat Pump 16.0 SEER Setback New
Duct
Cooling Duct Location R-Value Status
HVACgym Ducted
HVACpic Ducted
Ducted Attic 8.0
Ducted Attic 8.0
New
New
HVACsport Ducted
Ducted Attic 8.0
New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
2 Small Instantaneous Gas 0
0.96 Parallel Piping
New
Ener Pro 7.2 by Ener Soft User Number. 6712
ID:
Pae 16 of 33
RESIDENTIAL MEASURES SUMMARY
Project Name Building Type m Single Family ❑ Addition Alone
Lot50 Madison Club ❑ Multi Family ❑ Existing+ Addition/Alteration
.. .
Project Address California Energy Climate Zone Total Cond. Floor Area Addition
53-308 Ross Ave. La Quinta CA Climate Zone 15 10,326 n/a
INSULATION Area
Construction Type Cavity (ft) Special Features
RMS -1
Date
4/12/2019
# of Units
1
Status
FENESTRATION Io[ai Area. 1.500 Glazing Percentage: 14.55e I NewlAltered Average U -Factor: 0.42
Orientation Area(ft2) U -Fac SHGC Overhang Sidefins Exterior Shades Status
HVAC SYSTEMS
Qty. Heating
1 Split Heat Pump
1 Split Heat Pump
HVAC DISTRIBUTION
Location
Heati
HVACIiv
Ducted
HVACmstr
Ducted
HVACbed
Ducted
WATER HEATING
8.00 HSPF
Ig
Qtv. Type
New
Min. Eff
Cooling
Min. Eff
8.00 HSPF
Split Heat Pump
16.0 SEER
8.00 HSPF
Split Heat Pump
16.0 SEER
8.00 HSPF
Ig
Split Heat Pump 16.0 SEER
Cooling Duct Location
New
Ducted Attic
New
Ducted Attic
Ducted Attic
Gallons Min. Eff Distribution
User Number: 5T 12
Thermostat Status
Setback
New
Setback
New
Setback
New
Duct
R -Value
Status
8.0
New
8.0
New
8.0
New
Status
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. 'Exceptions may apply.
(Revised 04/20171
Building Envelope Measures:
§ 110.6(a)l:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per
NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011 '
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U -factors and solar heat gain coefficient (SHGC) values from TABLES
110.6-A and 110.6-8 for compliance and must be caulked and/or weatherstri ed.'
§ 103:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed, or weather stried.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material,
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the re uirements of § 1 10.8 i when the installation of a cool roof is specified on the CF1 R.
§ 110.8U):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U -factor must not exceed 0.043.
Minimum R-19 or weighted average U -factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a d wall ceiling.'
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R -value,
Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or U-
§ 150.0(():
factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U -factor not exceeding 0.102, equivalent to an installed
value of R-13 in a wood framed assembly.'
§ 150.0(d):
Raised -Floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U -factor.'
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration- and when installed as pM of a heated slab floor, meet there uirements of § 110,8(g).
§ 150.0(8)1:
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 1 50.0 d .
§ 150.0(g)2:
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
insulation in all exterior walls, vented attics, and unvented altics with air - permeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum Ll -factor of 0.58; or the weighted average U -factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)1A:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1 B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)1C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K,'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in woich the
cut -on temperature for compression healing is higher than the cul -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.'
§ 110.2(():
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(()5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(()5.
§ 110.3(()7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heaft systems to allow forwater tank flushing when the valves are closed.
§ 110.5:
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot ll hts that consume less than 150 Btu/hr are exempt): and pool and spa heaters'
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)l:
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions specified in § 150.0 h)2.
2016 Low -Rise Residential Mandatory Measures Summa
Liquid Line Drier, Installed air conditioner and heat oumo systems must ha aniunnari LOh f nand lino ri+or ,ir;ore ;fro
.1r4r1T'?.TXtr.'r Offl
§ 150.0(m)l
§ 150.0(m)2:
%,villpildilir. hn au-uisuiouuun sy5wm ducts ano plenums must De installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support plalforms must not be compressed to cause reductions in the cross-sectional area of the ducts.'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tape is used in combination with mastic and draw bands.
§ 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements s ecified for duct construction
§ 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually derated dam ers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, Including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)l1; occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0('m 11 and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occuplable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labaling.requirements of § 150.0(m)12.
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the intemal insulation R -value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures:
§ 150.00)26:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve.'
§ 150.00)X:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
i in for steam and h drdnic heatin systems or hot waters stems must meet the requirements in TABLE 120.3-A.'
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover, The cover must be water retardant and provide shieiding from solar radiation that can
rniuzp danrmorfalion of the material.
§ 150.00)36:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class Il vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve Individual dwelling units must include al! of the following: a
§ 150.0(n)l:
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without Pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation SRCC or by a I[sting agena that is approved bX the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
)
contractor installs the Insulation, the contractor must certifyto the customer, in wrilin , that the Insulation meets this requirement.
§ 150.0(m)l
§ 150.0(m)2:
%,villpildilir. hn au-uisuiouuun sy5wm ducts ano plenums must De installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support plalforms must not be compressed to cause reductions in the cross-sectional area of the ducts.'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tape is used in combination with mastic and draw bands.
§ 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements s ecified for duct construction
§ 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually derated dam ers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, Including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)l1; occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0('m 11 and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occuplable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labaling.requirements of § 150.0(m)12.
§ 150.0(m)13:
2016 Low -Rise Residential Mandajqry Measures Summa
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return
u, a". I Vl iN.al Doxes. I Ile nur, UGI VI eleGUIGal UUXeS lrldl dre rllUre man A feel above the finished floor and do not contain a luminaire or
R1lZA NLID•..8.....1..,,L....,.._+L.............�_. a L__aL__..�L___r L_�______ rte___ .. ..
y ��•�\.� Iu.
grilles, and an air -handling unit fan efficacy s 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
§ 150.0(k)1C:
forced airs stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(0):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
§ 150.0(o)1A:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
§ 150.0(k)1 E:
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
by vacancy sensors.
Certification by Manufacturers. Any pco€ or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater
must meet the applicable requirements of § 150.0(1k .'
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
resistance heatin .'
§ 110.4(b)1:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
JA8.'
suction and return lines, or bullt-In or bulit-up connections to allow for future solar heating,
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover,
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
_
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0
§ (p)'
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
rate, ppingfilters, and valves'
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
§ 150.0(k)2F:
of § 110.9.'
§ 110.9(e):
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
§ 150.0(k)2G:
be certified to the EnqM Commission according to Reference Joint Appendix JAB.
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Dr....6 CI:....1 D........ TL_ _...L__ _[ _I__a___I L_..__ __ ... ...
u, a". I Vl iN.al Doxes. I Ile nur, UGI VI eleGUIGal UUXeS lrldl dre rllUre man A feel above the finished floor and do not contain a luminaire or
R1lZA NLID•..8.....1..,,L....,.._+L.............�_. a L__aL__..�L___r L_�______ rte___ .. ..
y ��•�\.� Iu.
VUIOI UUVIUO IIIUJI UO IIU ll ealel Ulan rlle nunluel uI ueuruunls. I nese eleuirlcal boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires fn cellln s.
§ 150.0(k)1 D:
Electronic Ballasts, Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors.
§ 150.0(k)1 R
Lighting Integral to Exhaust Fans. Lighling integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(1k .'
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1 G:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8.'
§ 150.0(k)1 H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0 k .
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5 ; and meels all other requirements in _ 150.0(k)2,
Interior Switches and Controls An EMCS ma be used to com I with vacanct ' 150 0 k 'f' I
§ 150.0(k)2H:
§ 150.0(k)21:
Y p y y sensor requiremon s In § . ( ) I It meets a I of the
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5,,'9. and all other requirements in § 150.0 k 2.
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to § 1 W.9, and complies with all other applicable reouirements in $150.Ofkt2.
M_
2016 Low -Rise Residential Mandatory Measures Summary.
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference. Joint Appendix JA8, except luminaires in closets less than 70 square feet and luminaires in hallwa ;
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS.
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either § 150.0(k)3A or with the applicable requirements in §§ 110.9130.0 130.2 130.4, 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0(k)3B or§ 150.0(k)3D must comply with the applicable requirements in §§ 110.9,130.07 130.2 130.4, 140.7 and 141.0.
§ 150.0(1k)3D:
Residential Outdoor Lighting, Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per slte must comply with the applicable requirements in §§ 110.9, 130.0. 130.2 130.4, 140.7, and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
vowe as determined accordi N to § 1 30.0 c ,
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in 110.9 130.0, 130.1 130.4,140.6 and 141.0:
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)66:
I. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percenL The occupant sensors must be capable of turning the light fully on and off from all designed paths of inoress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.10 b Ihrou h § 1 10.10 e .
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110,10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1.
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.'
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical lane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110,10(c):
routing of conduit from the solar zone to the point of interconnection with the eleclrlcaI service (for single family residences the point of
interconnection will be the main service panal); and a pathway for routi ng of piumbin from the solar zone to the wate r -h eat! ngsystem.
§ 110.10(d):
Documentation, A copy of the construction documents or a comparable document indicattrng the information from § 11110(b) through
110.10 c must be provided to the occu ant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Lot 50 Madison Club
Date
4/12/2019
System Name
HVACgym
Floor Area
1,252
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING
CFM Sensible
Total Room Loads 825 17,147
Return Vented Lighting 0
Return Air Ducts 990
Return Fan 0
Ventilation 0 0
Supply Fan Oj
Supply Air Ducts 990
TOTAL SYSTEM LOAD 19,127
PEAK
COIL HTG.
PEAK
Sensible
19,628
Heating System
Latent
CFM
Output per System 55,600
1,410
503
Total Output Btuh 55,600
Output Btuh/s ft 44.4
750
Cooling System
0
output per System 56,500
0 0
0
Total Output Btuh 56,500
1,410
0
Total Output Tons 4.7
750
Total Output Btuh/s ft 45.1
Total Output s ft/Ton 265.9
21,129
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 25BNB760-FX4DNF006 42,051
5,645
34,726
Airflow (cfm/s ft)
1.60
Airflow cfm/Ton
424.8
Outside Air %
0.0%
Total Adjusted System Output 42,051
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
5,645
Aug 3 PM
34,726
Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditio:n:
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak)
26 OF
Ok
Outside Air
0 cfm
68 OF
68 OF 105 IF 105 OF
Heating Coil Supply Fan
2,000 cfm
105 OF
ROOM
68 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak)
112/78°F
Outside Air
0 cfm
75 / 62 °FJ
75!62°F 55/54°F 55/54°F
Cooling Coil Supply Fan 55 / 54 OF
2,000 cfm -
46.9% ROOM
1;
75 / 62 OF
II
VAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name Date
Lot 50 Madison Club I A/19/9nia
System Name
HVACpic
68 OF 105 OF
105 OF
Floor Area
2,599
ENGINEERING CHECKS
f
SYSTEM LOAD
Outside Air
�
Number of S stems
2
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL
CFM
740
0
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System 55,600
15,584
2,926
320
12,570
Total Output Btuh 111,200
0
ROOM
68 OF
Output Btuh/s ft 42.8
900
481
Cooling System I
0
0
Output per System 56,500
0
0
0 0
Total Output Btuh) 113,000
0
2,926
0
Total Output Tons 9.4
Total Output Btuh/s ft 43.5
900
481
Total Output s ft/Ton 276.0
17,384
13,531
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
4,000
Carrier 25BNB760-FX4DNF006
83,371
11,928
69,453
Airflow cfm fsq ft
1.54
Airflow cfmfron
424.8
Outside Air °I°
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
83,371
11,928
Aug 3 PM
69,453
Jan 1 AM
Outside Air cfmis ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak)
26 OF
68 OF 105 OF
105 OF
�
f
Outside Air
�
0 cfm
Heating Coil
Supply Fan
105 IF
4,000 cfm
ROOM
68 OF
68 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F 75/62°F 55/54°F 55/54°F
Outside Air �__^ ,J _._..�_ _. �• _ _
0 cfm Cooling Coil Supply Fan 55 / 54 OF
4,000 cfm -• -
47.0% ROOM
9.
75 / 62 °F75 / 62 IF
D_ I I I U 4 1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
68 OF 105 OF 105 OF
Project Name
Lot50 Madison Club
—..... _ . ................
hk
0 cfm
Heating Coil Supply Fan
Date
4/12/2019
System Name
HVACsport
105 IF
ROOM
68 OF
Floor Area
2,375
ENGINEERING CHECKS
SYSTEM LOAD
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
Number of Systems
1
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL
CFM
964
0
1
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
55,600
19,958
2,674
527
20,542
Total output Btuh
55,600
0
Output Btuh/s ft
23.4
1,152
785
Cooling System
0
0
Output per System
56,500
0
0
0
0
Total Output Btuh
56,500
0
2,674
0
Total Output Tons
4.7
1,152
785
Total Output Btuh/s ft
23.8
Total Output s ft/Ton
504.4
22,263
22,112
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 25BNB760-FX4DNF006
41,712
6,172
34,726
Airflow cfm/s ft
0.84
Airflow (cfm/Ton)
424.8
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
41,712
6,172
Aug 3 PM
34,726
Jan 1 AM
Outside Air cfmis ft
0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
68 OF 105 OF 105 OF
0_4 OP
Outside Air
hk
0 cfm
Heating Coil Supply Fan
2,000 cfm
105 IF
ROOM
68 OF
tL�
68 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F
76/62°F 55/54°F 55/54°Fn
Air
a IOutside
0 cfm
Cooling Coil Supply Fan
56 / 54 OF
2,000 cfm
--
47.7% ROOM
76
_ IL -
75/62°F
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Lot 50 Madison Club
Date
4/12/2019
Floor Area __
2,200
System Name
HVACliv
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems__
1
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL
CFM
1,002
0
1
COOLING
PEAK COIL HTG. PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output perSystem 55,600
20,721
2,477 486
18,962
Total Output Btuh 55,600
0
Output Btuh/s ft 25.3
1,196
725
Cooling System
0
0
Output perSystem
56,500
0
4
0 0
Total Output Btuh
56,500
0
2,477
0
Total Output Tons
4.7
1,196
725
Total Output Btuh/s ft
25.7
Total Output s ft/Ton
467.3
23,114
20,412
Air System
CFM perSystem
Airflow cfm
2,000
2,000
HVAC EQUIPMENT SELECTION
Carrier 25BNB760-FX4DNF006
41,810
6,052
34,726
Airflow cfm/s ft
0.91
Airflow cfmfron
424.8
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
41,810
6,052
Aug 3 PM
34,726
Jan 1 AM
Outside Air cfmis ft
0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heatin Peak
26 OF 68 OF 105 OF 105 OF
�
Outside Air y U-1
0 cfm Heating Coil Supply Fan
2,000 cfm
68 OF
105 OF
ROOM
68 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Tem eratures at Time of Cooling Peak
112/78°F 76/62°F 55/54°F 55/54°F
Outside Air
0 cfm Cooling Coil Supply Fan 56 / 54 OF
2,000 cfm -
47.5% ROOM
76/62°F 1 75/62°F
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Lot 50 Madison Club
Date
4/12/2019
System Name
HVACmstr
Floor Area
1,000
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems 1
COIL
CFM
Total Room Loads 865
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System
12,000
17,086
1,126 213
8,290
Total Output (Btuh)
12,000
0
Output (Btuh/sqft.L
12.0
986
317
Cooling System
0
0
Output per System_
12,000
0
0
0 0
Total Output Btuh
12,000
0
1,126
0
Total Output Tons
1.0
986
317
Total output Btuh/s ft
12.0
Total Output s ft/Ton
1,000.0
19,059
8,924
Air System
CFM per System
Airflow cfm
640
640
HVAC EQUIPMENT SELECTION
ducted split heat pump 8,329 1,906 7,495
Airflow cfm/s ft
0.64
Airflow cfm/Ton
640.0
Outside Air %
0.0%
Total Adjusted System Output 8.329 1.906
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
7,495
Jan 1 AM
Outside Air cfm/s ft
0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Tem eratures at Time of Heatin Peak
26 OF 68 OF 105 OF 105 OF
Outside Air
0 cfm Heating Coil Supply Fan
640 cfm 105 °F
ROOM
68 OF _ _ - 68 OF
�I I. I
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F 76/62°F 55/54°F 55/54°F
Q
Outside Air
0 cfm Cooling Coil Supply Fan 56 / 54 OF
640 cfm
48.0% ROOM
76 / 62 OF r
I
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Pmpci Name
Lot 50 Madison Club
Elate
4119/9n1 q
System Name
HVACbed
Floor Area
900
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
Total Room Loads 1
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL
CFM
781
0
COOLING
PEAK
COIL HTG.
PEAT{
Heating System
Sensible
Latent
CFM
Sensible
Output per System 12,000
15,524
1,013
190
7,409
Total Output Btuh) 12,000
0
Out ut Btuh/s ft 13.3
896
283
Cooling System
0
0
Output per System 12,000
0
0
0
0
Total Output Btuh 12,000
0
1,013
0
Total Output Tons 1.0
896
283
Total Output Btuh/s ft) 13.3
Total Output s ft/Ton 900.0
17,317
7,975
Air System
CFM per System
640
HVAC EQUIPMENT SELECTION
Airflow cfm
640
ducted split heat pump
8,289
1,930
7,495
Airflow (cfm/s ft)
0.71
Airflow (cfm/Ton)
640.0
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
8,289
1,930
Aug 3 PM
7,495
Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions I
rites I INN sYZPI tM t'ZSYC;MKUMt I KI[;5 Airstream iem eratures at Time of Heating Peak
26 OF 68 OF 105 OF 105 OF
Outside Air R� �♦
0 cfm Heating Coil Supply Fan
640 cfm 105 ° F
68 OF
ROOM
68 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F 76/62°F 55/54°F 55/54°F
Outside Air
0 cfm Cooling Coil Supply Fan 56 / 54 OF
640 cfm
76/62°F
47.8% ROOM
75/62°F
ZONE LOAD SUMMARY
Project Name Date
Lot 50 Madison Club II 4/12/2019
Systern Name Floor Area
HVACgym 1,252
ZONE LOAD SUMMARY
_ ZONAL SYSTEM COOLING PEAK HEATING PEAK
ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible
9Ym 1.0 0 Aug 3 PM 825 17.1471 1,410 503 19,628
TOTALS 0 0 0 0 Aug 3 PM 17.1471 1,410 19,628
(BLOCK LOAD)
ZONE LOAD SUMMARY
Pro e : Name
Lot 50 Madison Club Date 411212019
System Name
HVACpic Floor Area ZONE LOAD SUMMARY Z599
ZONAL SYSTEM COOLING PEAK HEATING PEAK
ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr I CFM Sensible Latent CFM Sensible
pickle 1.0 0 A-g3PMI 740 15,584 2,926 320 12,570
TOTALS 0 0 0 01 Aug 3 PM 15,584 29261 12,570
(BLOCK LOAD)
ZONE LOAD SUMMARY
Project I'Qa+-:e Date
_Lot 50 Madison Club 4/12/2019
Sys.am Name
HVACsport Floor Area
2,375
ZONE LOAD SUMMARY
I ZONAL SYSTEM COOLING PEAK HEATING PEAK
.... ZONE NAME I SYSTEM NAME Mult. CFM Sensible Latent Heatin OA CFM Peak Hr CFM Sensible Latent CFM Sensible
Lounge 1.0 0 Aug 3 PM 964 19,958 2,674 527 20,542
TOTALS 0 0 0 0 Aug 3 PM 19,958 2,674 20,542
(BLOCK LOAD)
ZONE LOAD SUMMARY
Project Name
Lot 50 Madison Club
Date
4/12/2019
System Name
HVACliv
Floor Area
2,200
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME SYSTEM NAME
Mult. CFM Sensible Latent Heating
OA CFM Peak Hr CFM Sensible I
Latent CFM Sensible
living kitchen hall
1.0
0 Aug 3 PM 1,002 20,721
2477 486 18,962
....... ...... ......�.
TOTALS 01 0 01
0 Aug 3 PM 20,721
2477 18,962
BLOCK LOAD
ZONE LOAD SUMMARY
Project Name Date
Lot 50 Madison Club 4/1212019
System lame
Floor Area
HVACmstr 1,000
ZONE LOAD SUMMARY
ZONAL SYSTEM COOLING PEAK HEATING PEAK
ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heatin OA CFM Peak Hr CFM Sensible Latent CFM Sensible
master 1.0 0 Aug 3 PM 865 17,086 1,126 213 8,290
TOTALS 0 0 01 0 Aug 3PM 17,086' 1,126 8,290
(BLOCK LOAD)
ZONE LOAD SUMMARY
Project Name
Lot 50 Madison Club
Date
4/12/2019
System Name
HVACbed
Floor Area
900
ZONE LOAD SUMMARY
ZONAL SYSTEM COOLING PEAK
HEATING PEAK
ZONE NAME SYSTEM NAME
Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible
Latent CFM Sensible
Bedroom
1.0 0 Aug 3 PM 781 15,524
1,013 190 7,409
TOTALS 0 0 0 0 Aug 3 PM 15,524
1,013 7,409
(BLOCK LOAD)