Loading...
BRES2019-0084T4'v 4 .fwQu,,�Krw 78-495 CALLE TAMPICO VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN &DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 4/24/2019 Permit Type/Subtype: BUILDING RESIDENTIAL/ADDITION Owner: Application Number: BRES2019-0084 THIS IS HOW WE DO IT LLC Property Address: 53308 ROSS AVE 53308 ROSS AVENUE APN: Application Description: 767680012 THIS IS HOW WE DO IT, LLC. / 76 S.F. GARAGE ADDITION LA QUINTA, CA 92253 Property Zoning: Application Valuation: $1,400.00 Applicant: Contractor: HUGO CERVANTES ° DISCOVERY BUILDERS CALIFORNIA INC DBA DB LA QUINTA, CA 92253 orf 4 �0+. # I 14605 N 73RD STREET SCOTTSDALE, AZ 85260 'NTA (480)624-5200 DESIGN & DEVELUM"VIEN I AMR, j Llc. No.: 915336 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 015336-- ` Contr;.actora . OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law For the following reason (Sec. 703 1.5, Business and Professions Code. Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to Its issuance, also requires the applicant for the permit to file a signed statement that he a she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code] or that he a she is exempt therefrom and the basis for the alleged exemp[ian. Any violation of Section 7031..5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_,) I, as owner of the property, a my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Prafesslons Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does Che work himself a herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement Is sola within one year of completion, the owner -bull will }lave the burden of proving that he APPLICANT ACKNOWLEDGEMENT Or she did not build or improve far the purpose of sale.). IMPORTANT: Application is hereby.made to the Building Official for a permit subject to L) I, as owner of the property, am extluslvely contract Ing with licensed contractors to the conditions and restrictions set forth on this application. construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State 1. Each person upon whose behalf this application is made, each person at whose License Law does not apply 10 an owner of property who builds or improves thereon, request and for whose benefit work is performed under or pursuant to any permit issued and who contracts for the projects with a contractors) licensed pursuant to the as a result of this application , the owner, and the applicant, each agrees to, and shall Contractors' State License Law.). defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and (_) I am exempt under Sec. B.&P.C. for this reason employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Sectlan 3700 of the Labor Code, for the performance of th ark f ar which this permit is sissued. ' ' ave and will maintain workers' compensation insurance, as required.by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are. Carrier TRAVELERS PRQEFRTY CAS JALTY COMPANY OF Policy Number. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 a bar Code, I shall forthwith comply with those provisions. bate: U-20Applicant"— —�- WARNING: FAILURE TO SECURE WO RS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER O CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. Date: Owner CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Add I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city toe ` up n the above- mentioned property for inspection purposes. Date: 2 • C) Signatuher(Applicant or Agent Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: HUGO CERVANTES LA QUINTA, CA 92253 BRES2019-0084 53308 ROSS AVE 767680012 THIS IS HOW WE DO IT, LLC. / 76 S.F. GARAGE ADDITION $1,400.00 Date: 4/24/2019 Owner: THIS IS HOW WE DO IT LLC 53308 ROSS AVENUE LA QUINTA, CA 92253 Contractor: DISCOVERY BUILDERS CALIFORNIA INC DBA DB 14605 N 73RD STREET SCOTTSDALE, AZ 85260 (480)624-5200 Llc. No.: 915336 Detail: REVISION TO PLANS FOR SINGLE FAMILY DWELLING CURE MY -LY UNDtlk tO,NSTRUCTION--REFERENCE SFD PERMIT BRES2018-0422. ADD 76 ADDITIONAL SQUARE FEET AT GARAGE + NEW WINDOW NEAR ENTRY HALL. DOES NOT INCLUDE INSTALLATION OF FIREPLACE. 2016 CODES. Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $103.90 FINANCIAL DESCRIPTION ACCOUNT QTY AMOUNT PLAN CHECK DEPOSIT - ADDITION/REMODEL 101-0000-42600 1 $125.00 Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($0.50) DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $0.50 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.00 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($17.77) DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($106.73) DESCRIPTION ACCOUNT QTY AMOUNT DOOR/WINDOW, NEW/ALT, FIRST 1 101-0000-42400 0 $106.73 DESCRIPTION ACCOUNT QTY AMOUNT DOOR/WINDOW, NEW/ALT, FIRST 1 PC 101-0000-42600 0 $17.77 DESCRIPTION ACCOUNTQTY AMOUNT DOOR/WINDOW, NEW/ALT, FIRST 1 PC 101-0000-42600 0 $103.90 Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $103.90 acaQigra Project Address: A P N #: '7I T - i/q4' -,0,q C/ IT # 1dYE3 r3rJIC1' PLAN LOCATION - Project Description: 3� Da,FD J7c��dNJ C, 42U riCY 7lJ J FWN Applicant Name: r�G `" ^►I y'JJ��l�� S A16OU 01 -1451s -JA [+ Address: M City,ST Zi 1 Gcy�4ci��� f Telephone: A&Wm / j ) Email:A(rrvaii (Q Valuation of Project $ Contractor Name: New SFD Construction: Address: Conditioned Space SF City, St, Zip Garage f7 ! SF Telephone: Patio/Porch SF Email: Fire Sprinklers SF State Lic: City Bus Lic: Architect/ Engineer Name: V Address: -" � City, St, Zip Telephone: Email: State Lic: City Bus Lic: Property Owner's Name: Address: City, ST, ip' D a L Telephone: Email: ' Construction Grading: Bedrooms: I Stories: Occupancy: I # Units: New Commercial / Tenant Improvements: Total Building SF Construction Type: Occupancy: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY #� Submittal Required Received Plan Sets � structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval 1 City Business License ! BUILDING ENERGY ANALYSIS REPORT PROJECT: Lot 50 Madison Club 53-308 Ross Ave. La Quinta, CA 92253 Project Designer: HC Design 51825 Avenida Volosco La Quinta, CA 92253 7607995244 Report Prepared by: Jon d. Scott Scott Design and Title 24, Inc, 74818 Velie Way Suite 8 Palm Desert, CA 92260�7-Y OF LA QCJINTA (760) 200-4780 BUILDING DIVISION REVIEWED FOA CODE COMPLIANCE Job Number: O Ce 55T ptl Date: APR 12 2019 4/12/2019 14 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. '.. I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R -PRF -01-E Certificate of Compliance Form RMS -1 Residential Measures Summary 1 2 3 16 Form MF -1 R Mandatory Measures Summary 18 CERTI' TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: 53-308 Ross Ave. Calculation Description: Title 24 Analysis ■ o - Calculation Date/Time: 12:54, Fri, Apr 12, 2019 Input File Name: Madison Lot 50-Hugo-18.dbd16x CF 'RF -01 Page 1 of 13 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name 53-308 Ross Ave. 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location 53-308 Ross Ave. Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 180 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ftZ) 10326 15 Number of Zones 6 16 Slab Area (ftZ) 10326 17 Number of Stories 1 18 Addition Cond. Floor Area(ft2) n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ft), n/a 21 Glazing Percentage (%) 14.5% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 218-P010334437D-000-000-0000000-0000 Registration DateMme: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-011 62 01 9-11 49 Report Generated at: 2019-04-12 12:55:29 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 1.32 2.21 -0.89 -67.4% Space Cooling IAQ Ventilation 67.18 1.09 61.37 1.09 5.81 0.00 8.6% 0.0% Water Heating 1.59 1.38 0.21 13.2% Photovoltaic Offset --- 0.00 0.00 — Compliance Energy Total 71.18 66.05 5.13 7.2% Registration Number: 218-P010334437D-000-000-0000000-0000 Registration DateMme: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-011 62 01 9-11 49 Report Generated at: 2019-04-12 12:55:29 CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE HOD CF 'RF -01 Project Name: 53-308 Ross Ave. Calculation Description: Title 24 Analysis Calculation Date/Time: 12:54, Fri, Apr 12, 2019 Input File Name: Madison Lot 50-Hugo-18.ribd16x Page 2 of 13 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 247 Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 47.8 45.2 0.0 45.2 ❑ Design meets Tier 1 requirement of 15°/a or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. Q Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on-site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Central parallel piping — HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • -- None -- Registration Number: 218-Po10334437D-000-000-0000000-0000 Registration Date/Time: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29 CERTI' TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: 53-308 Ross Ave. Calculation Description: Title 24 Analysis HOD Calculation Date/Time: 12:54, Fri, Apr 12, 2019 Input File Name: Madison Lot 50-Hugo-18.ribdl6x CF 'RF -01 Page 3 of 13 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 53-308 Ross Ave. 10326 1 18 6 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 gym Conditioned HVACgym1 1252 9 DHW Sys 1 n/a pickle Conditioned HVACpic2 2599 9 DHW Sys 1 n/a Lounge Conditioned HVACsport3 2375 9 DHW Sys 1 n/a living kitchen hall Conditioned HVACIiv4 2200 9 DHW Sys 1 n/a master Conditioned HVACmstr5 1000 9 DHW Sys 1 n/a Bedroom Conditioned HVACbed6 900 9 DHW Sys 1 n/a Registration Number: 218-Po10334437D-000-000-0000000-0000 Registration Dateffime: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29 CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: 53-308 Ross Ave. Calculation Description: Title 24 Analysis . We Calculation Date/Time: 12:54, Fri, Apr 12, 2019 Input File Name: Madison Lot 50-Hugo-18.ribdl6x CF 3RF-01 Page 4 of 13 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) N Wall gym R-21 Wall 0 Back 1020 504 90 E Wall gym R-21 Wall 90 Right 375 0 90 S Wall gym R-21 Wall 180 Front 125 0 90 W Wall gym R-21 Wall 270 Left 375 0 90 Interior Surface gym R-0 Interior Wall n/a n/a 566 0 n/a RoofR38R13gym gym R-38 Roof Attic n/a n/a 1252 n/a n/a E Wall 2 pickle R-21 Wall 90 Right 580 0 90 W Wall 2 pickle R-21 Wall 270 Left 580 0 90 Interior Surface 2 pickle R-0 Interior Wall n/a n/a 566 0 n/a Interior Surface 3 pickle R-0 Interior Wall n/a n/a 566 0 n/a Interior Surface 4 pickle R-0 Interior Wall n/a Na 566 0 n/a Interior Surface 5 pickle R-0 Interior Wall n/a n/a 566 0 n/a Interior Surface 6 pickle R-0 Interior Wall n/a n/a 566 0 n/a Interior Surface 7 pickle R-0 Interior Wall n/a n/a 566 0 n/a RoofR38R13pic pickle R-38 Roof Attic n/a n/a 2599 n/a n/a E Wall 3 Lounge R-21 Wall 90 Right 980 0 90 S Wall 2 Lounge R-21 Wall 180 Front 1052 180 90 W Wall 3 Lounge R-21 Wall 270 Left 620 0 90 Interior Surface 8 Lounge R-0 Interior Wall n/a n/a 566 0 n/a RoofR38R13sport Lounge R-38 Roof Attic n/a n/a 2375 n/a n/a N Wall 2 living kitchen hall R-21 Wall 0 Back 560 272.4 90 E Wall 4 living kitchen hall R-21 Wall 90 Right 380 0 90 S Wall 3 living kitchen hall R-21 Wall 180 Front 300 159 90 W Wall 4 living kitchen hall R-21 Wall 270 Left 560 0 90 Interior Surface 9 living kitchen hall R-0 Interior Wall n/a n/a 412 0 n/a RoofR38R13liv living kitchen hall R-38 Roof Attic n/a n/a 2200 Na n/a W Wall 5 master R-21 Wall 270 Left 540 209 90 Interior Surface 10 master R-0 Interior Wall n/a n/a 288 0 n/a Interior Surface 11 master R-0 Interior Wall n/a n/a 288 0 n/a Interior Surface 12 master R-0 Interior Wall n/a n/a 288 0 n/a Registration Number: 218-P010334437D-000-000-0000000-0000 Registration Dateff-ime: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29 CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE HOD CF 'RF -01 Project Name: 53-308 Ross Ave. Calculation Description: Title 24 Analysis Calculation Date/Time: 12:54, Fri, Apr 12, 2019 Input File Name: Madison Lot 50 -Hugo -1 8.ribdl 6x Page 5 of 13 Interior Surface 13 master R-0 Interior Wall n/a n/a 288 0 n/a Interior Surface 14 master R-0 Interior Wall n/a n/a 288 0 n/a Interior Surface 15 master R-0 Interior Wall n/a n/a 288 0 n/a Roofr38R13mstr master R-38 Roof Attic n/a n/a 1000 n/a n/a W Wall 6 Bedroom R-21 Wall 270 Left 380 200 90 Interior Surface 16 Bedroom R-0 Interior Wall n/a n/a 288 0 n/a Interior Surface 17 Bedroom R-0 Interior Wall n/a n/a 288 0 n/a Interior Surface 18 Bedroom R-0 Interior Wall n/a n/a 288 0 n/a Interior Surface 19 Bedroom R-0 Interior Wall n/a n/a 288 0 n/a Interior Surface 20 Bedroom R-0 Interior Wall n/a n/a 288 0 n/a Interior Surface 21 Bedroom R-0 Interior Wall n/a n/a 288 0 n/a Roofr38R13bed Bedroom R-38 Roof Attic i n/a n/a 900 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic gym Attic Roofgym Ventilated 0 0.1 0.85 No No Attic pickle Attic Roofpickle Ventilated 0 1 0.1 0.85 No No Attic Lounge Attic Roofl-ounge Ventilated 0 0.1 0.85 No No Attic living kitchen hall Attic Roofliving kitchen hall Ventilated 0 0.1 0.85 No No Attic master Attic Roofmaster Ventilated 0 0.1 0.85 No No Attic Bedroom Attic RoofBedroom Ventilated 0 0.1 0.85 No No Registration Number: 218-P010334437D-000-000-0000000-0000 Registration Dateff-ime: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29 CERTG TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE HOD CF 'RF -01 Project Name: 53-308 Ross Ave. Calculation DatelTime: 12:54, Fri, Apr 12, 2019 Page 6 of 13 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 50-Hugo-18.ribdl6x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Height Area Name Type Surface (Orientation -Azimuth) Width (ft) (ft) Multiplier (ftZ) U -factor SHGC Exterior Shading 42x12 Window N Wall (Back -0) - 1 504.0 0.42 0.21 Insect Screen (default) 15x12 Window S Wall 2 (Front -180) ---- -- 1 180.0 0.42 0.21 Insect Screen (default) 22.2x12 Window N Wall 2 (Back -0) - 1 272.4 0.42 0.21 Insect Screen (default) 5x10 Window S Wall 3 (Front -180) - - 1 60.0 0.42 0.21 Insect Screen (default) 7.5x10 Window S Wall 3 (Front -180) - 1 75.0 0.42 0.21 Insect Screen (default) 15x11 Window W Wall 5 (Left -270) -- 1 165.0 0.42 0.21 Insect Screen (default) 6x6 Window W Wall 5 (Left -270) -- - 1 36.0 0.42 0.21 Insect Screen (default) 4x2 Window W Wall 5 (Left -270) -- - 1 8.0 0.42 0.21 Insect Screen (default) 10x10 Window W Wall 6 (Left -270) - 1 100.0 0.42 0.21 Insect Screen (default) 10x10 2 Window W Wall 6 (Left -270) I- - 1 100.0 0.42 0.21 Insect Screen (default) OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ftZ) U -factor Door S Wall 3 24.0 0.50 Registration Number: e18-Poi0334437D-000-000-0000000-0000 Registration Date/Time: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29 CERTI' TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: 53-308 Ross Ave. Calculation Description: Title 24 Analysis ;-IOD Calculation Date/Time: 12:54, Fri, Apr 12, 2019 Input File Name: Madison Lot 50-Hugo-18.ribdl6x CF 'RF -01 Page 7 of 13 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -factor Assembly Layers • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0 /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck.' Wood Siding/sheathing/decking Attic Roofgym Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing. Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 R-0 Interior Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.277 Other Side Finish: Gypsum Board • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R -13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofpickle Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing., Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R -13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofl-ounge Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing., Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R -13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofliving kitchen hall Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing., Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R -13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofmaster Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing. Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0 /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck. Wood Siding/sheathing/decking Attic RoofBedroom Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing. Light Roof (Asphalt Shingle) Registration Number: 218-Po10334437D-000-000-0000000-0000 Registration Date/Time: 2019-04-1213:01:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29 CERTI ,TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: 53-308 Ross Ave. Calculation Description: Title 24 Analysis ■6o Calculation Date/Time: 12:54, Fri, Apr 12, 2019 Input File Name: Madison Lot 50-Hugo-18.ribd16x Cl 'RF -01 Page 8 of 13 SLAB FLOORS 01 02 03 04 05 06 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated Slab -on -Grade gym 1252 115 None 0.8 No Slab -on -Grade 2 pickle 2599 85 None 0.8 No Slab -on -Grade 3 Lounge 2375 136 None 0.8 No Slab -on -Grade 4 living kitchen hall 2200 56 None 0.8 No Slab -on -Grade 5 master 1000 36 None 0.8 No Slab -on -Grade 6 Bedroom 900 35 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Central Parallel Piping DHW Heater 1 (2) 2 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Input Rating! Tank Standby Heater Tank Uniform Energy Pilot / Insulation Loss / First Hour NEEA Heat Pump Tank Location Element Number Volume Factor/ Energy Thermal R -value Recovery Rating I Brand / Model / or Ambient Name Type Tank Type of Units (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Other Condition DHW Heater 1 Gas Small Instantaneous 2 0 0.96 EF <= 200 kBtu/hr R -0/R-0 0 n/a n/a n/a Registration Number: 218-Po10334437D-000-000-0000000-0000 Registration Date/Tme: 2019-04-12 13:01-24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29 CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: 53-308 Ross Ave. Calculation Description: Title 24 Analysis ■*a Calculation Date/Time: 12:54, Fri, Apr 12, 2019 Input File Name: Madison Lot 50-Hugo-18.ribd16x CF, 'RF -01 Page 9 of 13 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC m1 gy Heat Pump Heating and Cooling System Heat Pump System 1 Heat Pump System 1 HVAC Fan 1 Air Distribution System 1 HVACpic2 Heat Pump Heating and Cooling System Heat Pump System 2 Heat Pump System 2 HVAC Fan 2 Air Distribution System 2 HVACs ort3 p Heat Pump Heating and Cooling System Heat Pum p System 3 Heat Pum p System 3 HVAC Fan 3 Air Distribution System 3 HVACliv4 Heat Pump Heating and Cooling System Heat Pump System 4 Heat Pump System 4 HVAC Fan 4 Air Distribution System 4 HVACmstr5 Heat Pump Heating and Cooling System Heat Pump System 5 Heat Pump System 5 HVAC Fan 5 Air Distribution System 5 HVACbed6 Heat Pump Heating and Cooling System Heat Pump System 6 Heat Pump System 6 HVAC Fan 6 Air Distribution System 6 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 1 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 1 SplitHeatPump 1 8 55600 33360 16 12.5 Not Zonal Single Speed Heat Pump System 1 -hers -cool Heat Pump System 2 SplitHeatPump 2 8 55600 33360 16 12.5 Not Zonal Single Speed Heat Pump System 2 -hers -cool Heat Pump System 3 SplitHeatPump 1 8 55600 33360 16 12.5 Not Zonal Single Speed Heat Pump System 3 -hers -cool Heat Pump System 4 SplitHeatPump 1 8 55600 33360 16 12.5 Not Zonal Single Speed Heat Pump System 4 -hers -cool Heat Pump System 5 SplitHeatPump 1 8 12000 7200 16 12.5 Not Zonal Single Speed Heat Pump System 5 -hers -cool Heat Pump System 6 SplitHeatPump 1 8 12000 7200 16 12.5 Not Zonal Single Speed Heat Pump System 6 -hers -cool Registration Number: 218-P010334437D-000-000-0000000-0000 Registration Date/-l-ime: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29 CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE HOD CF" 'RF -01 Project Name: 53-308 Ross Ave. Calculation Date/Time: 12:54, Fri, Apr 12, 2019 Page 10 of 13 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 50 -Hugo -1 8.ribdl 6x HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Heat Pump System 1 -hers -cool Required 350 Required Required Required Heat Pump System 2 -hers -cool Required 350 Required Required Required Heat Pump System 3 -hers -cool Required 350 Required Required Required Heat Pump System 4 -hers -cool Required 350 Required Required Required Heat Pump System 5 -hers -cool Required 350 Required Required Required Heat Pump System 6 -hers -cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1 -hers -list Air Distribution System 2 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 2 -hers -dist Air Distribution System 3 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 3 -hers -dist Air Distribution System 4 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 4 -hers -dist Air Distribution System 5 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 5 -hers -dist Air Distribution System 6 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 6 -hers -dist Registration Number: 218-P010334437D-000-000-0000000-0000 Registration DateRme: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-01162019-1149 Report Generated at: 2019-04-12 12:55:29 CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: 53-308 Ross Ave. Calculation Description: Title 24 Analysis 0901 Calculation Date/Time: 12:54, Fri, Apr 12, 2019 Input File Name: Madison Lot 50-Hugo-18.ribd16x CF 'RF -01 Page 11 of 13 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1 -hers -dist Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 2 -hers -dist Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 3 -hers -dist Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 4 -hers -dist Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 5 -hers -dist Required 5.0 Not Required Not Required Not Required Not Required n/a Air Distribution System 6 -hers -dist Required 5.0 Not Required Not Required Not Required Not Required n/a HVAC -FAN SYSTEMS 01 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.54 HVAC Fan 1 -hers -fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.54 HVAC Fan 2 -hers -fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.54 HVAC Fan 3 -hers -fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.54 HVAC Fan 4 -hers -fan HVAC Fan 5 Single Speed PSC Furnace Fan 0.54 HVAC Fan 5 -hers -fan HVAC Fan 6 Single Speed PSC Furnace Fan 0.54 HVAC Fan 6 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.54 HVAC Fan 2 -hers -fan Required 0.54 HVAC Fan 3 -hers -fan Required 0.54 HVAC Fan 4 -hers -fan Required 0.54 HVAC Fan 5 -hers -fan Required 0.54 HVAC Fan 6 -hers -fan Required 0.54 Registration Number: 218-P010334437D-000-000-0000000-0000 Registration DateMme: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-04-12 12:55:29 CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE HOD CF 'RF -01 Project Name: 53-308 Ross Ave. Calculation Date/Time: 12:54, Fri, Apr 12, 2019 Page 12 of 13 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 50-Hugo-18.ribd16x IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 IAQ Recovery Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type Effectiveness(%) HERS Verification SFam IAQVentRpt 246 0.25 Default 0 Required Registration Number: 218-P010334437D-000-000-0000000-0000 Registration Date/Time: 2019-04-12 13:01:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-01162019-1149 Report Generated at: 2019-04-12 12:55:29 CERTII TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE Project Name: 53-308 Ross Ave. Calculation Description: Title 24 Analysis 40D Calculation Date/Time: 12:54, Fri, Apr 12, 2019 Input File Name: Madison Lot 50-Hugo-18.ribdl6x CF 'RF -01 Page 13 of 13 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2019-04-12 13:01:24 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature. Gfir,Jff/ Tim Scott Company: Date Signed: Scott Design and Title 24, Inc. 2019-04-12 13:01:24 Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 218-P010334437D-000-000-0000000-0000 Registration Date/Tme: 2019-04-12 13:01:24 CA Building Energy Efficiency Standards - 2016 Residential Compliance ReportVersion - CFIR-01162019-1149 t L Easy to Verify HERS Provider: CaICERTS inc. Report Generated at: 2019-04-12 12:55:29 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Lot 50 Madison Club Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/12/2019 Project Address 53-308 Ross Ave. La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area Addition 10,326 n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic R 38 10,326 Add=R-13.0 New Wall Wood Framed R 21 6,903 New Slab Unheated Slab-on-Grade no insulation 10,326 Perim = 463' New Demising Wood Framed no insulation 8,396 New Door Opaque Door no insulation 24 New FENESTRATION Total Area: 7.500 Glazing Percentage: 14.5% New/Altered Average U•Factor: Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades 0.42 Status Rear (N) 776.4 0.420 0.21 none none Bug Screen New Front (S) 315.0 0.420 0.21 none none Bug Screen New Left (W) 409.0 0.420 0.21 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 8.00 HSPF Split Heat Pump 16.0 SEER Setback New 2 Split Heat Pump 8.00 HSPF Split Heat Pump 16.0 SEER Setback New 1 Split Heat Pump 8.00 HSPF HVAC DISTRIBUTION Location Heating Split Heat Pump 16.0 SEER Setback New Duct Cooling Duct Location R-Value Status HVACgym Ducted HVACpic Ducted Ducted Attic 8.0 Ducted Attic 8.0 New New HVACsport Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Small Instantaneous Gas 0 0.96 Parallel Piping New Ener Pro 7.2 by Ener Soft User Number. 6712 ID: Pae 16 of 33 RESIDENTIAL MEASURES SUMMARY Project Name Building Type m Single Family ❑ Addition Alone Lot50 Madison Club ❑ Multi Family ❑ Existing+ Addition/Alteration .. . Project Address California Energy Climate Zone Total Cond. Floor Area Addition 53-308 Ross Ave. La Quinta CA Climate Zone 15 10,326 n/a INSULATION Area Construction Type Cavity (ft) Special Features RMS -1 Date 4/12/2019 # of Units 1 Status FENESTRATION Io[ai Area. 1.500 Glazing Percentage: 14.55e I NewlAltered Average U -Factor: 0.42 Orientation Area(ft2) U -Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating 1 Split Heat Pump 1 Split Heat Pump HVAC DISTRIBUTION Location Heati HVACIiv Ducted HVACmstr Ducted HVACbed Ducted WATER HEATING 8.00 HSPF Ig Qtv. Type New Min. Eff Cooling Min. Eff 8.00 HSPF Split Heat Pump 16.0 SEER 8.00 HSPF Split Heat Pump 16.0 SEER 8.00 HSPF Ig Split Heat Pump 16.0 SEER Cooling Duct Location New Ducted Attic New Ducted Attic Ducted Attic Gallons Min. Eff Distribution User Number: 5T 12 Thermostat Status Setback New Setback New Setback New Duct R -Value Status 8.0 New 8.0 New 8.0 New Status 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply. (Revised 04/20171 Building Envelope Measures: § 110.6(a)l: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011 ' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U -factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-8 for compliance and must be caulked and/or weatherstri ed.' § 103: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stried. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material, § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the re uirements of § 1 10.8 i when the installation of a cool roof is specified on the CF1 R. § 110.8U): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U -factor must not exceed 0.043. Minimum R-19 or weighted average U -factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a d wall ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R -value, Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or U- § 150.0((): factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U -factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.' § 150.0(d): Raised -Floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U -factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration- and when installed as pM of a heated slab floor, meet there uirements of § 110,8(g). § 150.0(8)1: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 1 50.0 d . § 150.0(g)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented altics with air - permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum Ll -factor of 0.58; or the weighted average U -factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)1 B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)1C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K,' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in woich the cut -on temperature for compression healing is higher than the cul -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.' § 110.2((): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(()5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(()5. § 110.3(()7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heaft systems to allow forwater tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot ll hts that consume less than 150 Btu/hr are exempt): and pool and spa heaters' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions specified in § 150.0 h)2. 2016 Low -Rise Residential Mandatory Measures Summa Liquid Line Drier, Installed air conditioner and heat oumo systems must ha aniunnari LOh f nand lino ri+or ,ir;ore ;fro .1r4r1T'?.TXtr.'r Offl § 150.0(m)l § 150.0(m)2: %,villpildilir. hn au-uisuiouuun sy5wm ducts ano plenums must De installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support plalforms must not be compressed to cause reductions in the cross-sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements s ecified for duct construction § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually derated dam ers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, Including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)l1; occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0('m 11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occuplable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labaling.requirements of § 150.0(m)12. manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the intemal insulation R -value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures: § 150.00)26: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.00)X: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution i in for steam and h drdnic heatin systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover, The cover must be water retardant and provide shieiding from solar radiation that can rniuzp danrmorfalion of the material. § 150.00)36: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class Il vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve Individual dwelling units must include al! of the following: a § 150.0(n)l: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without Pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a I[sting agena that is approved bX the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a ) contractor installs the Insulation, the contractor must certifyto the customer, in wrilin , that the Insulation meets this requirement. § 150.0(m)l § 150.0(m)2: %,villpildilir. hn au-uisuiouuun sy5wm ducts ano plenums must De installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support plalforms must not be compressed to cause reductions in the cross-sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements s ecified for duct construction § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually derated dam ers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, Including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)l1; occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0('m 11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occuplable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labaling.requirements of § 150.0(m)12. § 150.0(m)13: 2016 Low -Rise Residential Mandajqry Measures Summa Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return u, a". I Vl iN.al Doxes. I Ile nur, UGI VI eleGUIGal UUXeS lrldl dre rllUre man A feel above the finished floor and do not contain a luminaire or R1lZA NLID•..8.....1..,,L....,.._+L.............�_. a L__aL__..�L___r L_�______ rte___ .. .. y ��•�\.� Iu. grilles, and an air -handling unit fan efficacy s 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central § 150.0(k)1C: forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(0): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic § 150.0(k)1 E: testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: by vacancy sensors. Certification by Manufacturers. Any pco€ or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater must meet the applicable requirements of § 150.0(1k .' without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply resistance heatin .' § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated JA8.' suction and return lines, or bullt-In or bulit-up connections to allow for future solar heating, § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover, § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: _ Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. rate, ppingfilters, and valves' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements § 150.0(k)2F: of § 110.9.' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must § 150.0(k)2G: be certified to the EnqM Commission according to Reference Joint Appendix JAB. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Dr....6 CI:....1 D........ TL_ _...L__ _[ _I__a___I L_..__ __ ... ... u, a". I Vl iN.al Doxes. I Ile nur, UGI VI eleGUIGal UUXeS lrldl dre rllUre man A feel above the finished floor and do not contain a luminaire or R1lZA NLID•..8.....1..,,L....,.._+L.............�_. a L__aL__..�L___r L_�______ rte___ .. .. y ��•�\.� Iu. VUIOI UUVIUO IIIUJI UO IIU ll ealel Ulan rlle nunluel uI ueuruunls. I nese eleuirlcal boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires fn cellln s. § 150.0(k)1 D: Electronic Ballasts, Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 R Lighting Integral to Exhaust Fans. Lighling integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(1k .' Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0 k . § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 ; and meels all other requirements in _ 150.0(k)2, Interior Switches and Controls An EMCS ma be used to com I with vacanct ' 150 0 k 'f' I § 150.0(k)2H: § 150.0(k)21: Y p y y sensor requiremon s In § . ( ) I It meets a I of the following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5,,'9. and all other requirements in § 150.0 k 2. Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmer according to § 1 W.9, and complies with all other applicable reouirements in $150.Ofkt2. M_ 2016 Low -Rise Residential Mandatory Measures Summary. § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference. Joint Appendix JA8, except luminaires in closets less than 70 square feet and luminaires in hallwa ; § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0(k)3A or with the applicable requirements in §§ 110.9130.0 130.2 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0(k)3B or§ 150.0(k)3D must comply with the applicable requirements in §§ 110.9,130.07 130.2 130.4, 140.7 and 141.0. § 150.0(1k)3D: Residential Outdoor Lighting, Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per slte must comply with the applicable requirements in §§ 110.9, 130.0. 130.2 130.4, 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of vowe as determined accordi N to § 1 30.0 c , § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in 110.9 130.0, 130.1 130.4,140.6 and 141.0: Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)66: I. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percenL The occupant sensors must be capable of turning the light fully on and off from all designed paths of inoress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.10 b Ihrou h § 1 10.10 e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110,10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1. greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110,10(c): routing of conduit from the solar zone to the point of interconnection with the eleclrlcaI service (for single family residences the point of interconnection will be the main service panal); and a pathway for routi ng of piumbin from the solar zone to the wate r -h eat! ngsystem. § 110.10(d): Documentation, A copy of the construction documents or a comparable document indicattrng the information from § 11110(b) through 110.10 c must be provided to the occu ant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lot 50 Madison Club Date 4/12/2019 System Name HVACgym Floor Area 1,252 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 825 17,147 Return Vented Lighting 0 Return Air Ducts 990 Return Fan 0 Ventilation 0 0 Supply Fan Oj Supply Air Ducts 990 TOTAL SYSTEM LOAD 19,127 PEAK COIL HTG. PEAK Sensible 19,628 Heating System Latent CFM Output per System 55,600 1,410 503 Total Output Btuh 55,600 Output Btuh/s ft 44.4 750 Cooling System 0 output per System 56,500 0 0 0 Total Output Btuh 56,500 1,410 0 Total Output Tons 4.7 750 Total Output Btuh/s ft 45.1 Total Output s ft/Ton 265.9 21,129 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 25BNB760-FX4DNF006 42,051 5,645 34,726 Airflow (cfm/s ft) 1.60 Airflow cfm/Ton 424.8 Outside Air % 0.0% Total Adjusted System Output 42,051 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 5,645 Aug 3 PM 34,726 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditio:n: HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 26 OF Ok Outside Air 0 cfm 68 OF 68 OF 105 IF 105 OF Heating Coil Supply Fan 2,000 cfm 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak) 112/78°F Outside Air 0 cfm 75 / 62 °FJ 75!62°F 55/54°F 55/54°F Cooling Coil Supply Fan 55 / 54 OF 2,000 cfm - 46.9% ROOM 1; 75 / 62 OF II VAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Lot 50 Madison Club I A/19/9nia System Name HVACpic 68 OF 105 OF 105 OF Floor Area 2,599 ENGINEERING CHECKS f SYSTEM LOAD Outside Air � Number of S stems 2 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 740 0 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 55,600 15,584 2,926 320 12,570 Total Output Btuh 111,200 0 ROOM 68 OF Output Btuh/s ft 42.8 900 481 Cooling System I 0 0 Output per System 56,500 0 0 0 0 Total Output Btuh) 113,000 0 2,926 0 Total Output Tons 9.4 Total Output Btuh/s ft 43.5 900 481 Total Output s ft/Ton 276.0 17,384 13,531 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 4,000 Carrier 25BNB760-FX4DNF006 83,371 11,928 69,453 Airflow cfm fsq ft 1.54 Airflow cfmfron 424.8 Outside Air °I° 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 83,371 11,928 Aug 3 PM 69,453 Jan 1 AM Outside Air cfmis ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 26 OF 68 OF 105 OF 105 OF � f Outside Air � 0 cfm Heating Coil Supply Fan 105 IF 4,000 cfm ROOM 68 OF 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 75/62°F 55/54°F 55/54°F Outside Air �__^ ,J _._..�_ _. �• _ _ 0 cfm Cooling Coil Supply Fan 55 / 54 OF 4,000 cfm -• - 47.0% ROOM 9. 75 / 62 °F75 / 62 IF D_ I I I U 4 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY 68 OF 105 OF 105 OF Project Name Lot50 Madison Club —..... _ . ................ hk 0 cfm Heating Coil Supply Fan Date 4/12/2019 System Name HVACsport 105 IF ROOM 68 OF Floor Area 2,375 ENGINEERING CHECKS SYSTEM LOAD COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 964 0 1 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 55,600 19,958 2,674 527 20,542 Total output Btuh 55,600 0 Output Btuh/s ft 23.4 1,152 785 Cooling System 0 0 Output per System 56,500 0 0 0 0 Total Output Btuh 56,500 0 2,674 0 Total Output Tons 4.7 1,152 785 Total Output Btuh/s ft 23.8 Total Output s ft/Ton 504.4 22,263 22,112 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 25BNB760-FX4DNF006 41,712 6,172 34,726 Airflow cfm/s ft 0.84 Airflow (cfm/Ton) 424.8 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 41,712 6,172 Aug 3 PM 34,726 Jan 1 AM Outside Air cfmis ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 105 OF 105 OF 0_4 OP Outside Air hk 0 cfm Heating Coil Supply Fan 2,000 cfm 105 IF ROOM 68 OF tL� 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 76/62°F 55/54°F 55/54°Fn Air a IOutside 0 cfm Cooling Coil Supply Fan 56 / 54 OF 2,000 cfm -- 47.7% ROOM 76 _ IL - 75/62°F HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lot 50 Madison Club Date 4/12/2019 Floor Area __ 2,200 System Name HVACliv ENGINEERING CHECKS SYSTEM LOAD Number of Systems__ 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 1,002 0 1 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 55,600 20,721 2,477 486 18,962 Total Output Btuh 55,600 0 Output Btuh/s ft 25.3 1,196 725 Cooling System 0 0 Output perSystem 56,500 0 4 0 0 Total Output Btuh 56,500 0 2,477 0 Total Output Tons 4.7 1,196 725 Total Output Btuh/s ft 25.7 Total Output s ft/Ton 467.3 23,114 20,412 Air System CFM perSystem Airflow cfm 2,000 2,000 HVAC EQUIPMENT SELECTION Carrier 25BNB760-FX4DNF006 41,810 6,052 34,726 Airflow cfm/s ft 0.91 Airflow cfmfron 424.8 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 41,810 6,052 Aug 3 PM 34,726 Jan 1 AM Outside Air cfmis ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heatin Peak 26 OF 68 OF 105 OF 105 OF � Outside Air y U-1 0 cfm Heating Coil Supply Fan 2,000 cfm 68 OF 105 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Tem eratures at Time of Cooling Peak 112/78°F 76/62°F 55/54°F 55/54°F Outside Air 0 cfm Cooling Coil Supply Fan 56 / 54 OF 2,000 cfm - 47.5% ROOM 76/62°F 1 75/62°F HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lot 50 Madison Club Date 4/12/2019 System Name HVACmstr Floor Area 1,000 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 865 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 12,000 17,086 1,126 213 8,290 Total Output (Btuh) 12,000 0 Output (Btuh/sqft.L 12.0 986 317 Cooling System 0 0 Output per System_ 12,000 0 0 0 0 Total Output Btuh 12,000 0 1,126 0 Total Output Tons 1.0 986 317 Total output Btuh/s ft 12.0 Total Output s ft/Ton 1,000.0 19,059 8,924 Air System CFM per System Airflow cfm 640 640 HVAC EQUIPMENT SELECTION ducted split heat pump 8,329 1,906 7,495 Airflow cfm/s ft 0.64 Airflow cfm/Ton 640.0 Outside Air % 0.0% Total Adjusted System Output 8.329 1.906 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 7,495 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Tem eratures at Time of Heatin Peak 26 OF 68 OF 105 OF 105 OF Outside Air 0 cfm Heating Coil Supply Fan 640 cfm 105 °F ROOM 68 OF _ _ - 68 OF �I I. I COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 76/62°F 55/54°F 55/54°F Q Outside Air 0 cfm Cooling Coil Supply Fan 56 / 54 OF 640 cfm 48.0% ROOM 76 / 62 OF r I HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Pmpci Name Lot 50 Madison Club Elate 4119/9n1 q System Name HVACbed Floor Area 900 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads 1 Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 781 0 COOLING PEAK COIL HTG. PEAT{ Heating System Sensible Latent CFM Sensible Output per System 12,000 15,524 1,013 190 7,409 Total Output Btuh) 12,000 0 Out ut Btuh/s ft 13.3 896 283 Cooling System 0 0 Output per System 12,000 0 0 0 0 Total Output Btuh 12,000 0 1,013 0 Total Output Tons 1.0 896 283 Total Output Btuh/s ft) 13.3 Total Output s ft/Ton 900.0 17,317 7,975 Air System CFM per System 640 HVAC EQUIPMENT SELECTION Airflow cfm 640 ducted split heat pump 8,289 1,930 7,495 Airflow (cfm/s ft) 0.71 Airflow (cfm/Ton) 640.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 8,289 1,930 Aug 3 PM 7,495 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions I rites I INN sYZPI tM t'ZSYC;MKUMt I KI[;5 Airstream iem eratures at Time of Heating Peak 26 OF 68 OF 105 OF 105 OF Outside Air R� �♦ 0 cfm Heating Coil Supply Fan 640 cfm 105 ° F 68 OF ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 76/62°F 55/54°F 55/54°F Outside Air 0 cfm Cooling Coil Supply Fan 56 / 54 OF 640 cfm 76/62°F 47.8% ROOM 75/62°F ZONE LOAD SUMMARY Project Name Date Lot 50 Madison Club II 4/12/2019 Systern Name Floor Area HVACgym 1,252 ZONE LOAD SUMMARY _ ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible 9Ym 1.0 0 Aug 3 PM 825 17.1471 1,410 503 19,628 TOTALS 0 0 0 0 Aug 3 PM 17.1471 1,410 19,628 (BLOCK LOAD) ZONE LOAD SUMMARY Pro e : Name Lot 50 Madison Club Date 411212019 System Name HVACpic Floor Area ZONE LOAD SUMMARY Z599 ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr I CFM Sensible Latent CFM Sensible pickle 1.0 0 A-g3PMI 740 15,584 2,926 320 12,570 TOTALS 0 0 0 01 Aug 3 PM 15,584 29261 12,570 (BLOCK LOAD) ZONE LOAD SUMMARY Project I'Qa+-:e Date _Lot 50 Madison Club 4/12/2019 Sys.am Name HVACsport Floor Area 2,375 ZONE LOAD SUMMARY I ZONAL SYSTEM COOLING PEAK HEATING PEAK .... ZONE NAME I SYSTEM NAME Mult. CFM Sensible Latent Heatin OA CFM Peak Hr CFM Sensible Latent CFM Sensible Lounge 1.0 0 Aug 3 PM 964 19,958 2,674 527 20,542 TOTALS 0 0 0 0 Aug 3 PM 19,958 2,674 20,542 (BLOCK LOAD) ZONE LOAD SUMMARY Project Name Lot 50 Madison Club Date 4/12/2019 System Name HVACliv Floor Area 2,200 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible I Latent CFM Sensible living kitchen hall 1.0 0 Aug 3 PM 1,002 20,721 2477 486 18,962 ....... ...... ......�. TOTALS 01 0 01 0 Aug 3 PM 20,721 2477 18,962 BLOCK LOAD ZONE LOAD SUMMARY Project Name Date Lot 50 Madison Club 4/1212019 System lame Floor Area HVACmstr 1,000 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heatin OA CFM Peak Hr CFM Sensible Latent CFM Sensible master 1.0 0 Aug 3 PM 865 17,086 1,126 213 8,290 TOTALS 0 0 01 0 Aug 3PM 17,086' 1,126 8,290 (BLOCK LOAD) ZONE LOAD SUMMARY Project Name Lot 50 Madison Club Date 4/12/2019 System Name HVACbed Floor Area 900 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible Bedroom 1.0 0 Aug 3 PM 781 15,524 1,013 190 7,409 TOTALS 0 0 0 0 Aug 3 PM 15,524 1,013 7,409 (BLOCK LOAD)