Loading...
BWFE2019-006078-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: c&t�p 4 i4P Qa6t&) DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT WALL/FENCE/CITY STANDARD/PRE-APPROVED B W FE2019-0060 77841 CALLE SONORA 773272023 PALMER / 42LF GARDEN WALLS AT EAST AND WEST SIDE YARD $2,000.00 Applicant: KEVIN FARMER CONSTRUCTION D 53460 AVENIDA MADERO LA QUINTA, CA 92253 APR 0 5 2019 U CITY OF LAQUINTA DESIGN & DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000} of Division 3 of the Bus] s and Professions Code, and my License is in full force and effect. License Class: B License No.: 678677 J Date:Ar--Tt .11 I' I Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: () I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). () I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/5/2019 Owner: PALMER LUANNE M & GERALD B 77841 CALLE SONORA LA QUITA, CA 92253 Contractor: KEVIN FARMER CONSTRUCTION 53460 AVEN IDA MADERO LA QUINTA, CA 92253 (760)469-7057 Llc. No.: 678677 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit Is issued. My workers' compensation Insurance carrier and policy number are: CarrlevUI MPT Policy Number: I certifythat in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of SA3700bor Code, I shall forthwith comply with those provisions. 4Date: ApplicaWARNING: FAILURE TO SECURE WORKN COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned 1P roperty for inspection purposes.2 Date: ' / Signature (Applicant or Agent). Application Number: BWFE2019-0060 Property Address: 77841 CALLE SONORA APN: 773272023 Application Description: PALMER / 42LF GARDEN WALLS AT EAST AND WEST SIDE YARD Property Zoning: Application Valuation: $2,000.00 Applicant: KEVIN FARMER CONSTRUCTION 53460 AVENIDA MADERO LA QUINTA, CA 92253 Owner: PALMER LUANNE M & GERALD B 77841 CALLE SONORA LA QUITA, CA 92253 Contractor: KEVIN FARMER CONSTRUCTION 53460 AVENIDA MADERO LA QUINTA, CA 92253 (760)469-7057 Llc. No.: 678677 Dat^: .4/5/2019 Detail: 22LF OF G GARDEN WALL AT EAST EXTERIOR SIDE YARD [ANGELUS S -1.11-Q SPECIFICATIONS] NOT TO ENCROACH INTO THE PUBLIC 12' RIGHT-OF- WAY, AND 20LF OF 6' GARDEN WALL AT WEST SIDEYARD. [ANGELUS S-1.0LQ SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. 2016 CALIFORNIA BUILDING CODES. DESCRIPTION FINANCIAL .• ♦. ACCOUNT QTY AMOUNT WALL/FENCE - FIRST 100 LF 101-0000-42404 0 $53.37 DESCRIPTION ACCOUNT QTY AMOUNT WALL/FENCE - FIRST 100 LF PC 101-0000-42600 0 $66.71 Total Paid for BLOCK WALL: $120.08 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 ta Qwkra CALIFORNIA — PERMIT # PLAN LOCATION: Project Address: -77gqI C1R_�L S600 _Project Description: APN #:� Garage y SF Telephone: Patio/Porch SF Applicant Name:��� Fire Sprinklers SF Address: -� -7 City, ST, Zip: Telephone: - _ �(✓�j Email: Valuation of Project $ Contractor Name: New SFD Construction: Address: Q J Conditioned Space SF City, St, Zip Garage y SF Telephone: Patio/Porch SF Email: Fire Sprinklers SF State Lic: -�7 City Bus Lic: Architect/ Engineer Name: Construction Occupancy: Address: Total Building SF Grading: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: New Commercial / Tenant Improvements: Address: �A(-Afto z, Total Building SF City, ST, Zip1 i'ATelephone:Cj Construction Type: Occupancy: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal Required Received Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License Y APR 0 4 M9 CITYOFLAQUINTA COMMUNITY DEVELOPMENT CITY OF I �UILDING & APPF FOR COP m 14 111041c�t�� 5ao1 I k OUINTA AFETY DEPT juCTICN -dp" a F ,.,i w7i� -77s& 4t t A v A 'P 11 . " ql. �N 04WBLOCK�nClMj, INC. ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2016 CBC 2. ALLOWABLE SOIL BEARING PRESSURE = 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf 4. COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf 5. CANTILEVER ACTIVE = 30pcf 6. MASONRY COMPRESSIVE STRENGTH, fm = 1500psi. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. NOTES: 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE. 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMEIFRS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 2. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD -DRAWN STEEL WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES. 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi ® 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE -AND -GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E -Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E -Z MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000psi. 7. FIRST COURSE MAY BE WET -SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. 8. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'-0"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED 10. GROUT ALL CELLS WITH REINFORCEMENT 11. INSPEC11ONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK-OUT DETAILS SEE DETAIL SHEET S-5.1. 13. DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE MASONRY FENCE WALL SCHEDULE 'H' MAX. ____'X'BARS 16' LONG CMU 18" LONG CMU 'B' MIN. 711- 6'-13" 4040"o.c. 4®45"o.c. 2'-1" 7'-4" 4032"o.c. 4036"o.c. 1 2'-3" 8' 0" 4®24"o.c. 1 44027"o.c. 1 2'-6" CIML228 INC. ITECTURE � ENGINEERING Badillo Street j Covina, CA 91723 38 1595 38 0485 6' to 8' High Site Wall Concentric Spread Footing C o 110mph (ult) Risk Category I 6' Wide CMU OPTIONAL WALL CAP 6 STD. LADDER TYPE #5 STI] FOR SLUMPSTONE) JOINT REINF. AT TOP COURSE AT FIRST COURSE, AND 24"o.c. 6" WIDE (NOM.) CMU GROUT CELLS — w/ REINF. 'X' BARS PER SCHEDULE CTR. OF WALL DWLS. TO MATCH VERT. REINF. LAP 24" MIN. EQ. F.G. - WET -SET FIRST COURSE 2-#4 CONT w X 0 ¢ _ � U x En uj w o_ w z o EQ. w Z g x J 0 CONT. CONC. FTG., - ALT. BENDS 'B' MIN. PER SCHEDULE CITY OF LA QUINTA BUILDING DIVISION APPROVED FOR CONSTRUCTION BY: A. DATE: 09/21/2018 of ESSIO, a 3" CLR, TYP. Na' 85681 I EXP. 9-30-20 # C I V OF C pG�F DATE SIGNED 9-10-18 S-1.OLQ #16-077 10 B*CM, ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2016 CBC 2. ALLOWABLE SOIL SEARING PRESSURE = 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf 4. COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf 5. CANTILEVER ACTIVE = 30pcf 6. MASONRY COMPRESSIVE STRENGTH, fm = 1500psi. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. NOTES: 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 6' to 8' High Site Wail Eccentric Spread Footing C a 110mph Wit) Risk Category I 6" Wide CMU OPTIONAL WALL CAP 1 I t STD. LADDER TYPE /5 STD FOR SLUMPSI JOINT REINF. AT TOP COURSE, AT FIRST COURSE, AND 24"o.c. 2. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD—DRAWN STEEL 'H' MAX.X BARS 16' LONG CMU 18' LONG CMU WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES 6'-0" 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi ® 28 DAYS, UNLESS 6" WIDE (NOM.) CMU GROUT CE LS OTHERWISE REQUIRED BY SOILS REPORT. w/ REINF_ 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR 7'-4" 4032'o.c. 4036"o.c. WITHOUT MORTARLESS HEAD JOINTS (TONGUE—AND—GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 8'-0" 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPORTIONS AND 'X' BARS PER REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS SCHEDULE MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPERTY CTR. OF WALL REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000psi. 7. FIRST COURSE MAY BE WET—SET 1 1/2 INCHES MAX. WHILE CONCRETE DWLS. TO MATCH IS PLASTIC. VERT. REINF. LAP - 8. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH 24" MIN. VERTICAL CONTINUITY OF THE CELLS. 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF F. G. 40'-0"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED WET—SET FIRST 10. GROUT ALL CELLS WITH REINFORCEMENT. COURSE 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL 2—#4 CONT REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK—OUT DETAILS SEE DETAIL SHEET S-5.1. CONT. CONC. F1 13. DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE MASONRY FENCE WALL SCHEDULE 'H' MAX.X BARS 16' LONG CMU 18' LONG CMU 'B' MIN 6'-0" 4 48' o.c. 4054"o.c. 2'--6" 6'-8" 4040"o. c. 4045"o.c. 2'-9" 7'-4" 4032'o.c. 4036"o.c. 3'-0'' 8'-0" 4®24"o.c.4®27"o.c. S-3" GHL INC. ARCHITECTURE - ENGINEERING 228 East Badillo Street I Covina, CA 91723 T. 626.938.1595 F: 626.93&0485 _ www ghloe-com CITY OF LA QUINTA BUILDING DIVISION APPROVED FOR CONSTRUCTION BY: A.DATE: 09/21/2018 w J J rn 1a 3" CLR. TYP. 'B' MIN. PER SCHEDULE NO. 85681 # EXP. 9-30-20 �} S'9T C I V OF' CA��F DATE SIGNED 9-10-18 S-1.1LQ #16-077