Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
7068
Finance Revenue Code E-1 F9 ENCROACHMENT PERMIT PUBLIC WORKS CONSTRUCTION For the construction of public or private curbs, driveways, pavements, sidewalks, parking lots, sewers, water mains and other like public works improvements in connection with MINOR IMPROVEMENTS and APPROVED SUBDIVISIONS. Subdivision Improvement Permit - Class 111 Minor Improvement Permit Class IV DATE:March 26, 2007 LOCATION OF CONSTRUCTION (Street address or Description): Verizon Upgrade #24 / Calle Temecula & Ave. Carranza / WO0543- 7PAOBU-H4019 PURPOSE OF CONSTRUCTION: Install PVC piping and various sized hand holes for fiber optics DESCRIPTION OF CONSTRUCTION: See attached maps and plans DIMENSION OFINSTALLATION OR REMOVAL: See attached maps and plans APPROXIMATE TIME WHEN WORK WILL BEGIN:April 1, 2007 TIME OF COMPLETION: December 31, 2007 ESTIMATED CONSTRUCTION COST: $117,000 (Including removal of all obstruction, materials, and debris, backfilling, compaction and placing permanent resurfacing and/or replacing improvements) COMMENTS: In consideration of the granting of this permit, the applicant hereby agrees to: Indemnify, defend and save the City, its authorized agents, officers, representatives and employees, harmless from and against any and all penalties, liabilities or loss resulting from claims or court action and arising out of any accident, loss or damage to persons or property happening or occurring as a proximate result of any work undertaken under the permit granted pursuant to this application. Notify the Administrative Authority at least twenty-four (24) hours in advance of the time when work will. be started at (760) 777- 7075. Comply with all applicable City Ordinances, the terms and conditions of'the permit and all applicable rules and regulations of the City of La Quinta and to pay for any additional replacement necessary as the result of this work. Signature of Applica or Agent Verizon - Darywl Bowden 870 Mountain Ave Upland CA 91786 (909) 608 1358 Name of Applicant (please print) Business Address Telephone No. Name of Contractor and Job Foreman Business Address TBA Contractor's License No. Applicant's Insurance Company FEES: Subdivision Improvement Permit - Class III Ct� F IF Minor Improvement Permit - Class IV Inspection Fee Permit Fee As -Built. Deposit Cash Deposit -Surety Bond, if required. TOTAL $3,510.00 $1.00.00 $0 $0 $ 3,610.00 Telephone No. ' 1 TBA ity Business License No. g 200� PAI4cv Number Public improvements: 3% of estimated construction costs Private improvements: 3% of estimated construction costs See attached schedule PERMIT NO.7068 DATE APPROVED: 144K Zf . 2.0p7 EXPIRATION DATE: N/,g,Q: Zg Zoo$ BY: Administrative Authority re vl �o W e n N 4 w wr o m p Ji J O ti tl � v N � O oz � N b t�O V h � o 0 0 �oo OO1110 �pON a rrrf�� a�o�$'000 �o . N ° � o 0 r' w !al'[[ w,7 lOYi ara np os' p 09 ^s m � cS ss oS RY• r a ti w ►C efi O?O -NO Ydl1 0 Or377VA VOMMAV e 09 - . r • - . - . L r a ••, a to to m. Of p 11 u, ®I t _: j® ® 08 �O e A 40 z�mv�r raolMD.. H M ro+c ;® ® oft 8:0 ip p0 . �O OS 09 7® 09 *sin B 0 _ e 04 A b I ? h o al oWv ® o o 9 . Va/N3RV 0 p �--'— M 8 78 b as Q �. VVIGAV °R sac -Oro rfu w� 090 rsi • 4 — Veu oh oa' b tt b �0 w to of S W p ►�W7 oo�-aw •rs OO -Oro nu W • J J o� oL 0 p OOV&VA7V °a . , VUMAV I� o of inn Nil YSWYoei4 ba? T / 4-2 25- 6/ r• R. A. 020-015 voR. N 112 SEC 13 r6S. R.6F tH/SMAP IS FOR 020-050 ASSESSMENT. PURPOSES ONLY 020 - 062 020-069 020- 076 020- 089 020-/02 2/ J eidr aiµ n raa ora • osa 9 /o 10,, 20 /42 N dro•Or8 N J ® ®3 N 4 ® rr oro• oer ©4 a tJ 1� S 6 O Ig 6 TNA Old. dd0 7 O �7 8 Q8 nA Ord • dye 9 9 kO it J MAOR/D off p4 @ / © r^ ago -Oro ° O • IM • 110 91 4MISA ra I Q %I 16 ® /O I®� W. oto•ose m /0 /p ® /0 v to, ro /4 ®// // // // _po 1.e_ a &V Bo Be 7e 'je p6 p /3 aplltd /2 Te 1e U�I�il �`on rr d arw ep, ' a/a1 p•� -arq „ 17e SAtT I 26 a/TII 161.dII� •80•IIa 50-1111. SANrA CARMrUMWVALELA QU,NM ter NQ 26 MB 20150 NO. 27MB /9182 • a J!/LY /967 rrmeCULA dATA ppIYNY +tyD•rlr0 . PoI fS.lfQ ' J 28 tJAN 181998 ASSESSOR'S AIAP K• S R/VERS/e cOUNTY CAL/ - - -...._... _ ..._........ .. ... ._ ...... �..-- -. _ .__.. _..._._...._._-.,..._...._...r. - ....ram + z3dl/mVY MVN3Ad a a W CL q 4. 'A ►. I. m o� I °. zz � ~Q A'�I � ai � .� � N N = o•. q m � b lam � b 8 � 76 I + 17NI+hQw D17/N3AV 60F o 79, ' e a orbat b ao A N °► ° R a %AN Bz I 79 1 0 0 ec ataoee aA1 oc AQi'J3!!80 VIWASAV w 'ter 0 Mrw rai � O Q ze ® Og ®� Q ®y Z Z mo I ti d W78 Z �o 0 c�'000 ooa ° a Op bo°O — a°ci000 0 0 0IR, Q W J V or OY � I N 0 h OOVWA7V VOIV3Ad A "s 1\ I 81 Z I I �� \ ap4 la I 01 b A b 01 u a m i YEN o a l 7�78 A I oY � a clone V0lN3AV a N, ws e G -e 8 G) © 'e-D E) o `` 8 it�0�3 ' � of of � •S � oS• y7 os � oso-lava � F O zvia t!OlN3At/ . h A N O A4a� rry w rr � ti4 >C\ 0 ah� " gam` a e (Z� e P, Q � r : r Yr• ai�Sg - — Z r, n i LOT � � � �� m 3&01" 5ei' �60.0e• 1- � � S0_00• � 9AOe' � Se.Oe- � •' 60.aP � _. Sq®• 10 5♦L 00• O Se_00'- m o� _o Do wo :ono ao 1 gym` L K 311 a sa Or mas OS WILM7 59_i� s saes' $ ace jib.@r 1 �F a VA Lr a��i/f-id-i-B"tF- -- LOT L.— Ed-e'---- — �g— 0 � r•t I � w r C r� �O Qs rn a 3 - �NNNNNNN! Apo 0000a?c mSgobbbo� Nq bPONaPDt t LD N \.. ., v w s w .. P . •P 119• s a 9e' : •AOe• SeeO- 50.®I � 1 d pO v r 13LK 13131 s - ge O ��� • p��o, m � �� o 0 0 0= - Ol SL*W mar a S s City of La Quinta The following General and Special Provisions are attached to and made a part of Permit Number 7068 The followina shall always apply: ENCROACHMENT ON PRIVATE PROPERTY: This permit authorizes work to be accomplished within the City of La Quinta's right of way ONLY. Whenever construction extends within private property, it is the responsibility of the permittee for his contractors to secure permission from abutting property owners. Such authorization must be secured by the permittee prior to starting work. TRACK -LAYING CONSTRUCTION EQUIPMENT: Cleated track -laying construction equipment shall not be permitted to operate on any paved surface unless fitted with smoother -faced street pads. All mechanical outriggers shall be fitted with rubber street shoes to protect the paving during excavations. Rubber -tired equipment only shall be used in backfill operation in paved areas. If the existing pavement is scarred, spalled, or broken during the term of this contract or if the pavement is marred, City of La Quinta shall request that these portions of road be resurfaced over their entire width. Resurfacing shall consist of one coat of two inches (2") of A.C. surfacing plus appropriate seal coat as specified above. PROTECTION OF TRAFFIC: All excavations and work areas shall be properly lighted and barricaded as deemed necessary by the City Engineer or City of La Quinta Public Works Inspectors. Suitable detours and detour signs shall be placed and maintained for the duration of the project. The City shall be notified twenty-four hours (24) in advance of any traffic detours or delineation. CARE OF DRAINAGE STRUCTURES: Any drainage structure to include corrugated metal pipe, concrete pipe, steel culvert and concrete structures encountered during excavation which necessitate removal shall be replaced in kind. In the event it becomes necessary to remove or cut existing drainage structures, City of La Quinta shall be notified prior to commencement of this work. Drainage structures and open drains shall be kept free of debris at all times for proper drainage. RIGHT-OF-WAY CLEANUP: Any surplus material resulting from excavation and backfill operations shall be removed from the right of way. All paved surfaces shall be broomed clean of earth and other objectionable materials immediately after backfill and compaction. Existing gutter line and drainage ditches shall be replaced to their original standard or better. All excess material shall be removed prior to paving. Water tanker shall be used, as required, to sprinkle the job site to keep down dust conditions and shall be used immediately after backfill. DE -WATER OPERTATIONS: If de -watering operations are required and pumps are forcing water on City of La Quinta roads, it shall be the responsibility of the permittee (contractor) to control this water and to provide off-street barricades when necessary. CLOSING STREETS: No street shall be closed. A minimum of one lane of traffic shall be maintained at all times to provide limited access for the adjoining property owners and emergency vehicles. In the event it is felt by the permittee that he must close a street for any length of time, permittee shall contact this,office to obtain the necessary permission. SPECIAL PROVISIONS The following shall apply when indicated: ® R1 NOTIFICATION: Permittee shall be notified the City at (760) 777 - 7097 at least forty-eight hours (48) in advance of starting construction. ® R2 UTILITY CLEARANCE: (Substructures) Prior to making any excavations within the City of La Quinta right-of-way authorized by permit, the permittee shall contact all concerned utility companies relative to the location of existing substructures. Damage to existing substructures resulting from operations conducted under this permit shall be the sole responsibility of the permittee. ® R3 UTILITY CLEARANCE (Surface Structures) No work shall be done under this permit until all utilities are clear of the proposed work site. The permittee shall notify all concerned utility companies of the proposed work. ❑ R4 PAVEMENT WIDENING: Area between the proposed concrete gutter line and the existing road pavement shall be surfaced with ( " N/A " ) inches of A.C. paving placed on ( " N/A " ) inches of ( " N/A " ) aggregate sub -base course having an "R" value of not less than ( " N/A ") and in conformance with the City of La Quinta Road Improvement Standards and Specifications, Ordinance #461. ® R5 PARKWAY GRADING: Area between the property line and top of the proposed concrete curb shall be graded to a slope of one-fourth inch (%") to one foot (1'). ❑ R6 GRADE CHECKING: City of La Quinta shall check grades upon receipt of plan and profile and/or grades as established by a licensed engineer. ❑ R7 CURB REMOVAL FOR DRIVEWAYS: A portion of the existing concrete curb and/or curb and gutter (" N/A ") feet shall be removed. Curb and/or curb and gutter shall be saw cut prior to removal. Depressed curb, matching concrete gutter and concrete driveway approach shall be constructed in conformance with City of La Quinta Standard #207. ❑ R8 DRIVEWAYS: A.C. driveways shall be constructed as not to alter existing drainage pattern. Surfacing between the property line and the existing road paving shall be two and a half inches (2 '%") of A.C. paving on (" N/A ") of class (" N/A " ) aggregate base. ® R9 SIGHT CLEARANCE: Sight Clearance of six -hundred feet (600') in all directions shall be assured and maintained at all times. ❑ R10 SOIL STERILIZER: The area to be surfaced shall be treated with soil strerilizer. Rate of application shall comply with the manufacturer's specifications. Citv of La Quinta ® R11 COORDINATE WORK: The proposed work shall be subordinated to any operation, which the State of California or City of La Quinta may conduct in this area during the period of this permit. Work shall be coordinated with the State or City of La Quinta forces to preclude delay or interference with State or City of La Quinta projects. ® R12 SURVEY MONUMENTS: Prior to excavation or beginning of construction, all survey monuments which exist on the centerline of all streets or property lines when included shall be completely tied out so they may be readily and correctly, replaced by a licensed civil engineer or surveyor at the expense of the permittee. A complete set of notes showing the ties to these monuments shall be furnished to the City Engineer prior to the removal of any monuments. This office shall be notified upon completion or replacement of all survey monuments for proper clearance. ® R13 PAVEMENT CUTTING: Pavement will be mechanically saw cut to a straight edge prior to excavation. Method of pavement cutting shall be approved through the office of the City Engineer. (Under no circumstances shall excavating equipment be used to excavate prior to cutting or pavement.) Excavation material shall be placed in such a position as to best facilitate the general flow traffic. Prior to final paving operations, any damage to pavement straight edges shall be corrected. ❑ R14 LIMIT OF EXCAVATIONS: Excavations shall be limited to one -thousand feet (1000') of open trench before backfill operations must begin. All excavations shall be properly barricaded with lights overnight, on weekends and holidays for the protection of the traveling public. The Public Works Inspector shall determine the suitability of excavation barricading in each case. No excavation shall remain open for a period exceeding five (5) days. No excavation shall be made unless the construction material is actually on the work site. ® R15 BACKFILL MATERIAL: Backfill shall be free of brush, roots or other organic substance detrimental to its use for purposes of producing and adequately consolidated backfill. Ant material which the City of La Quinta deems unsuitable (spongy or saturated material) which is encountered during excavation shall not be used for backfill, but shall be supplemented or replaced by an approved sand or gravel. ❑ R16 BACKFILL SAND: Backfill shall be approved transit -mix sand or equivalent and shall be placed on lifts not greater than three feet (3') and vibrated using vibrostamper or equivalent equipment. Alternate methods may be substituted, but in any case, a relative compaction of ninety-five percent (95%) shall be maintained with the structural section of the roadway. ❑ R17 BACKFILL PLACEMENT: Backfill shall be applied in layers of not more than fifty percent (50%) of the total depth of the trench before flooding or a maximum of five feet (5) lifts where trenches are of excessive depths. Care is to be exercised that the backfill material is not subjected to extreme swell by flooding operations. Backfill material shall be placed so that the resulting compaction shall not be less than ninety percent (90%) or equivalent to the surrounding ground, whichever is the greater compaction. Where ponding or flooding is used for a maximum settlement, adequate dikes will be constructed to retain the water. Where jetting is used, the jets shall be of sufficient length to reach the bottom of each layer and the water supply shall be continuos. ❑ R18 COMPACTION TESTS: If so required by the inspector, compaction test shall be made at intervals of not more than one - thousand (1000') feet and a maximum of one (1) test on each road. One (1) copy of each test shall be forwarded tot the City Engineer for approval and filed prior to making permanent repairs. Compaction tests shall be made as outlined in Section 6.3.01 of the Standard Specifications, Division of Highways, State of California, dated January 1973. ❑ R19 COMPACTION TESTS: If so required by the Inspector, compaction tests shall be made for each crossing or service line. One (1) copy of each test shall be forwarded to the City Engineer for approval and filed prior to making permanent repairs. Compaction tests shall be made as outlined in Sections 6.3.001 of the Standard Specifications, Division of Highways, State of California, dated January 1973. . ® R20 TEMPORARY PAVEMENT REPAIRS: After completion of backfill and compaction operations, a temporary patch consisting of two inches (2") of SC-800 shall be placed on a prepared sub -grade: The SC-800 temporary paving shall be placed after a maximum of three -thousand linear feet (3000') or trench has been excavated and backfill operations completed, but in no case shall the placement of the temporary pavement exceed a five (5) day limit. ® R21 PERMANENT PAVEMENT REPAIR: After backfill and compaction have been completed, a temporary patch consisting of two inches (2") of SC-800 shall be placed immediately. A permanent patch of ( " N/A " ) inches of A.0 surfacing placed on a ( " N/A ") inch ( crushed ) aggregate base shall be placed no later than ( 5 ) days after completion of temporary road repair. ❑ R22 FOG SEAL: A fog seal coat consisting of an application of asphaltic emulsion shall be applied over all patch areas as determined by the City Engineer. ® R23 STREET RESTRIPING: Where street striping is still visible on street to be excavated, such striping shall be replaced upon completion of permanent repairs. ® R24 TREE RELOCATION OR REMOVAL: Tree relocation within the City of La Quinta road right-of-way shall be accomplished by a licensed, bonded and insured tree service, and handled safely without interference or hazard to the traveling public. It shall be the responsibility of the permitte to maintain the tree in a vigorous growing condition at its new location. Trees to be removed shall be in sections, which can be handled safely without interference or hazard to highway traffic. The entire width of the tree stump, shall be removed and disposed of so that no debris remains in view of the highway. The stump hole shall be backfilled and thoroughly compacted as specified in the following paragraph. Where it becomes necessary to restrict traffic, the work shall be restricted to a maximum of five -hundred feet (500') at any one time. Adequate signs, flagmen and or barricades shall be provided to protect the traveling public at all times. Large holes resulting from tree removal shall be backfilled and compacted to not less than ninety percent (90%) or equivalent tot the surrounding ground, whichever is the greater compaction as determined by the impact or field method. Compaction tests shall comply with Section 6.3.01 of the Standard Specifications, Division of Highways, State of California, dated January 1973. 1 PERMIT NO.7068 Verizon Fiber Optic Upgrade #24 W.O.0543 — 7PFAOBU — H 4019 / Install PVC Piping for Fiber Optics/ Calle Temecula & Avenida Carranza In addition to the standard permit conditions; the following shall apply: Pursuant to Section 14.16.320 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), all work shall be performed in accordance with the latest edition of the Standard Specifications For Public Works Construction (SSPWC) and as directed by and to the satisfaction of the City Engineer. 2. Prior to commencing the excavation of a trench 5 feet in depth or greater and into which a person will be required to descend, the Contractor shall first obtain a permit to do so from the Division of Industrial Safety pursuant to 7-10.4.1. 3. "The permittee shall not construct an improvement that reduces vehicular sight distances. If such improvement is found to reduce the vehicular sight distance, then the permittee shall relocate the improvement prior to sign off of their encroachment permit." 4. The pennittee shall not install improvements with the intention ofproviding video transmission services unless the permittee obtains a valid Franchise Agreement. 5. The permittee shall remove any underground utility markings that are no longer being used for this project. The permittee shall remove markings on paved areas using high pressure wash or a method equivalent and at the discretion of the City Engineer. 6. Any asphaltic or concrete repairs shall closely match the existing paved areas in color at the discretion. of the City Engineer. A finish product with a checkerboard appearance will not be accepted. 7. The pennittee shall maintain the existing pedestrian path of travel and must maintain ADA complaint pathways leading to areas fur use of public transportation systems. 8. No stockpiling of any materials will be allowed within the City R/W without an approved permit explicitly stating the use for stockpiling and/or storage. 9. The permittee shall provide a list of individuals that can provide immediate assistance to the public. The permittee is responsible for assisting the public which have inquires with regard to this project. The list shall be provided to the city and attached to this permit. This list of individuals with phone numbers shall be identified on the proposed door hangers which the pennittee shall provide 481irs prior to start of any work, which includes marking of the underground utilities. The individuals identified on this list shall be capable of responding on any work day and within 1 hour of any work day. 10. Door hangers shall be provided to all residents affected by the project. At a minimum, the door hanger shall provide the following information: a. Short description of the improvements. (Include Verizon as the applicant and permit number.) b. Schedule of the improvements Special Conditions Page I of 8 PERMIT NO.7068 Verizon Fiber Optic Upgrade #24 W.O.0543 — 7PFAOBU = H 4019 / Install PVC Piping for Fiber Optics/ Calle Temecula & Avenida Carranza C. Suggested alternate routes of travel d. Phone numbers and individuals for questions and answers with the city being the last phone number, (760)-777-7075. 11. This permit or copy of it shall be on the work site (usually the job trailer) for inspection during the actual work performed. 12. Verizon and TBD Contractor, hereinafter referred to as "Permittee", shall be responsible for providing continuous dust and erosion control. 13. Streets shall be kept clean. They shall be completely cleaned at the end of each working day and more frequently, if required. 14. Pursuant to Section 6.08.050 of the La Quints Municipal Code (Ordinance 18 § 1, 1982), throughout the work site, the Permittee shall comply with City regulated work hours. Operation and maintenance of equipment within one-half mile of human occupancy shall be performed only during the following time periods: October 1 st to April 30: Monday -Friday 7:00 a.m. to 5:30 p.m. Saturday 8:00 a.m. to 5:00 p.m. May 1st to September 30: -Monday-Friday 6:00 a.m. to 7:00 p.m. Saturday 8:00 a.m. to 5:00 p.m. Work shall be prohibited on legal holidays and Sundays. Note: Construction work (including setting up traffic control devices) is not permitted on any Arterial street (ie any 4 lane street) before 8:00 a.m. . 15. Work within 500 feet of a signalized intersection shall be performed between the hours of 9 a.m. - 3 p.m. Traffic control shall be set up after 9 a.m. and removed before 3 p.m. The Permittee shall contact the Riverside Country Traffic Signal Maintenance Department at (951) 955-6894 if signal operation at the intersection is to be altered in any way. 16. Pursuant to Section 14.16.110 of the La .Quinta Municipal Code (Ordinance 10 § l (part), 1982), Permittee shall assume responsibility for repair of any pavement damage to any public or private street and for any damage to other City streets or facilities as a result of work performed under this permit. 17. This permit is not valid until the permittee submits, to the Public Works Department 2 weeks prior to start of construction, a letter from any owners of the driveways/access ways that will be closed down due to the construction. The letter must be approved by the city and at minimum state from the owner the following: Special Conditions Page 2 of 8 PERMIT NO.7068 Verizon Fiber Optic Upgrade #24 W:O.0543 - 7PFAOBU — H 4019 / Install PVC Piping for Fiber Optics/ Calle Temecula & Avenida Carranza A. Approval of the construction B. Plan identification C. Time Frame of Closure D. Alternative Routes 18. The permittee shall place temporary no parking signs along the parking area affected by the construction. The signs shall be placed along the area 48hrs prior to the start of closing the area, and removed immediately after the construction completion date. 19. Pursuant to Section 14.16.250 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), at residential streets, advance warning signs and traffic control shall be installed and maintained in accordance with Cal Trans Standards or the Work Area Traffic Control Handbook (WATCH Manual). A traffic control plan shall be prepared in accordance with the WATCH Manual. On Collector to Major Arterial Streets, the permittee must submit a traffic control plan which shall be prepared under the guidance of the Manual of Uniform Traffic Control Devices (MUTCD) 2003 Edition with Revision No. 1 Incorporated, dated November 2004 (HTML) and the California Supplement.. As of October of 2006, these documents can be observed at http://mutcd.fhwa.dot.gov/HTM/2003rl /part6/part6-toc.htm and http://www.dot.ca. og v/hg/traffops/signteclVmutcdsupp/pdf/CA-Chap6A-Chgp6F.pdf, respectively. It shall be the Permittee's responsibility to appropriately detour and barricade all construction sites. Pursuant to Section 14.16.290 of the La Quinta Municipal Code (Ordinance 10 § I (part), 1982), street closures shall not be permitted. A minimum of two (2) travel lanes of paved surface shall be maintained at all times. Special Conditions Page 3 of 8 PERMIT NO.7068 Verizon Fiber Optic Upgrade #24 W.O.0543 — 7PFAOBU — H 4019 / Install PVC Piping for Fiber Optics/ Calle Temecula & Avenida Carranza 20. Prior to excavating, if required, the Permittee shall contact Underground Service Alert at 1-800-422- 4133. It shall be the Pennittee's responsibility to notify the Public Works Department of anticipated excavation which impact City facilities, including but not limited to traffic signal conduits and loops, irrigation lines, electrical conduits, and storm drain facilities. 21. Should additional work, materials, or modifications of the work be required in order to meet City standards, safety requirements, signage requirements, or to fit actual field conditions, the work shall be performed by the Permittee as directed by and to the satisfaction of the City Engineer at no cost to the City of La Quinta. 22. The permittee shall be responsible for calling the city inspector to arrange the city inspector to observe random trench compaction testing performed by a city approved material testing firm. If the inspector's phone number is unknown, the permittee shall call the Public Works front counter phone at 777-7075 or the Assistant Engineer II at 777-7047 to determine the city inspector's phone number. The inspector shall determine the number and location of the test location/s. The above testing does not relieve the permittee's responsibility for future repairs due to settlement at and near the locations of the work area. Materials testing must be performed under direct supervision of a California Registered Civil Engineer. 23. The issuance of this permit and the City approval of the related construction improvement plans do not provide a vested entitlement for all design parameters that may have been utilized for the plans. As such, plans approved for this permit may be "at risk" for further modifications as it relates to any follow up improvement plan requirements as required by the city or existing errors & omissions by the architect or engineer of record. 24. This permit is not valid until the permittee submits, to the Public Works Department 2 weeks prior to start of construction, the name of the City approved contractor, who shall submit to the City the following items: a. General Liability Insurance Company and Policy Number b. City Business License c. Contractors State License Number 25. The permittee shall not encroach upon private property without prior written approval (submit to the Public Works Department, attention to the Assistant Engineer II) of the private land owner whom is being encroached upon. 26. Prior to performing construction work and closing any lanes in the Public Right of Way, the permittee shall call the City at (760) 777-7097 at least 48hrs prior to work and request an appointment for a preconstruction meeting with the City Inspection staff. 27. The permittee shall haul all offsite debris to a certified landfill. Prior to hauling debris, the permittee shall inform the City (Inspection staff or 777-7047) of the name and location of the certified dump site. Special Conditions Page 4 of 8 1 PERMIT NO.7068 Verizon Fiber Optic Upgrade #24 W.O.0543 — 7PFAOBU — H 4019 / Install PVC Piping for Fiber Optics/ Calle Temecula & Avenida Carranza 28. Prior to excavating in native soils, the owner of the project shall have employed by proposal contract an archaeological observer for the site excavations within native undisturbed soils. A copy of the contract must be submitted to the Public Works Department and attention this to the Assistant Engineer II. If the archaeologist determines the site note to be required to be observed, please submit a letter signed by the archaeologist stating their determination. 29. If public traffic lanes are required to be closed, this permit is not valid until the permittee submits, to the Public Works Department, an approved traffic control plan at least 2 weeks prior to start of construction or parking on the paved R/W. 3..0. The permittee is required to provide an informative message board (approved by the City Engineer) informing the commuters using the affected public Primary Arterial roads or heavier traffic of possible traffic delays, time of construction, and if possible alternate routes. The message board shall be provided for the commuters 48 hours prior to the start of traffic delays. 31. Pursuant to Section 14.16.370 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), backfill compaction within street rights -of -way shall conform to Section 306-1.3 of the latest edition of the Standard Specifications for Public Works Construction (SSPWC), except as otherwise specified herein. Native material may be used as backfill material provided that minimum compaction, achieved in the manner prescribed herein, is achieved. Backfill shall be performed by mechanical means; no water densified compaction via jetting or flooding or other means shall be allowed. It shall be the Permittee's responsibility to provide appropriate geotechnical supervision, testing, and inspection, onsite, at all times during backfill operations. Backfill compaction shall be achieved by the following conditions: A. When a firm foundation is not encountered due to soft, spongy or other unsuitable material, such material shall be removed to the limits directed by the Geotechnical Inspector and/or the City Inspector and the resulting excavation backfilled with pipe bedding material. B. Backfill materials shall be brought to or maintained at appropriate moisture content for compaction. The appropriate moisture content range shall be established at the onset of the project and ensured prior to use of the materials through progress testing on the stockpiles. C. The first length of trench backfilled shall be backfilled in the presence of the City Inspector. Compaction shall be tested at random depths at approximate three-foot vertical intervals as backfill is placed to ensure the effectiveness of the compaction methods and to establish the depth of lift that can be compacted. D. If lifts greater than one foot are attempted in this trial length of trench, compaction tests shall be taken within the lifts to ensure that the full depth of the lift is compacted. Upon satisfactory Special Conditions Page 5 of 8 PERMIT N0. 7068 Verizon Fiber Optic Upgrade #24 W.O.0543 — 7PFAOBU — H 4019 / Install PVC Piping for Fiber Optics/ Calle Temecula & Avenida Carranza completion of this portion of trench, the City Inspector shall establish the maximum lift thickness to be compacted for the remainder of.the project. E. In subsequent lengths of trench, the frequency of compaction tests shall equal one per each lift of backfill, per 300 linear feet of open trench, at randomly selected locations within the open length of trench. F. The depth of the randomly selected compaction tests shall also be randomly selected except that where multiple tests are required in a given length of trench, the tests shall be no closer than three feet (vertically) from each other. G. If any compaction test fails, previously placed backfill (in the same length of open trench or previous lengths of trench) which is represented by the failing test (as determined by the City Inspector), shall be tested for compliance with compaction requirements. H. All costs incurred due to the conditions above shall be borne by the Permittee. Copies of all test results shall be furnished to the City Inspector. 32. All excavations within City of La Quinta right-of-way shall be backfilled, and temporarily paved if within the existing travel way, at the end of every workday as directed by and to the satisfaction of the City Engineer for the protection of the public. Lengths of open trench shall not greatly exceed that which can not be backfilled in the same day. Excavated trenches shall not be allowed open overnight, however, Permittee may leave a length of excavated trench, not to exceed twenty (20) feet in length, open overnight at a point where construction will begin the next day, provided that this length of trench is completely covered by steel plating. 33. All landscaping, irrigation, decorative rock, decorative concrete, lighting, etc., shall be replaced to its original condition. 34. Access and egress to all local properties shall be maintained at all times 35. Pursuant to Section 14.16.375 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982), permanent pavement replacement shall be completed no later than seven (7) days after the completion of the work. Permanent pavement replacement shall conform to the following conditions: A. Existing asphalt concrete pavement shall be sawcut one (1) foot beyond trench edges. Edges shall be straight and clean. B. Permanent pavement replacement structural section, within all trenches, shall be 1" thicker than existing of asphalt concrete over the same existing thickness of crushed aggregate base or crushed miscellaneous base, meeting the requirements of Sections 200-2.2 and 200-2.4 of the Standard Special Conditions Page 6 of 8 PERMIT NO.7068 Verizon Fiber Optic Upgrade #24 W.O.0543 — 7PFAOBU — H 4019 / Install PVC Piping for Fiber Optics/ Calle Temecula & Avenida Carranza Specifications for Public Works Construction. The replaced pavement and base material shall be compacted to 95% relative compaction and respectively tested, for each 300 linear feet of trench. Verify exact structural replacement section thicknesses with the City prior to installation. C. Permanent pavement replacement shall be installed using a City approved 3/" max medium asphalt concrete as the base course lift and a City approved'h" max medium finish course lift for capping. Asphalt concrete mix design shall be approved by the City prior to its placement. D. Cold -Mill and Overlay - The existing pavement which was properly protected in place during the trenching operation located adjacent to the trench saw cut shall be cold -milled to a depth of 0.10 feet with butt joint created next to the existing unmilled pavement surface. The cold -milled area and base asphalt concrete in the trench area shall be overlaid with a City approved C2-AR-4000 asphalt concrete mix. The width of the cold milling area shall be as follows: For longitudinal trenches located in a parking lane: three (3) feet outside the sawcut removal lines. For longitudinal trenches located in a traffic lane: three (3) feet outside the sawcut removal lines, or to the lane line striping, whichever is greater. For transverse trenches across existing street: two (2) feet outside the sawcut removal lines. E. If grinding and capping operations are not performed in the same day as base paving operations, the base course lift of 3/" max medium asphalt concrete shall be installed from saw -cut edge to saw -cut edge flush with the existing street surface. The base course lift of paving shall not be left 0.10' low in anticipation of grinding and capping. F. Any existing lane striping or any existing detour lane striping affected by this resurfacing shall be replaced in kind by the Permittee, as directed by and to the satisfaction of the City Engineer. Affected traffic signal loops shall be removed and replaced in kind. The finished pavement surface shall be smooth, consistent, and shall conform to the surrounding grades. 36. Permittee shall permanently stabilize any and all soil that was disturbed as a result of work performed under this permit with an approved dust control treatment. Soil stabilization shall be done immediately after completing the operation. 37. Pursuant to Chapter 12.56 of the La Quinta Municipal Code (Ordinance 10 § 1 (part), 1982) the City has designated certain city streets as Truck Routes. The weight limit for restricted streets (i.e., streets not part of the Truck Route network) is three (3) tons; trucks exceeding the weight limit may use a restricted street if making a delivery or pickup on the subject street, or if this permit specifically grants permission to use the street to deliver street construction materials and/or equipment. 38. The City of La Quinta reserves the right to revoke, suspend or void this permit at any time. Special Conditions Page 7 of 8 7 PERMIT NO.7068 Verizon Fiber Optic Upgrade #24 W.O.0543 — 7PFAOBU — H 4019 / Install PVC Piping for Fiber Optics/ Calle Temecula & Avenida Carranza 39. The permittee shall indemnify, hold harmless and assume the defense of the City from all damages, delay costs, costs or expenses in law or equity that may arise out of work under this permit. 40. If it is the intent of the permittee to cut the pavement and have it restored by a third party, the permittee shall postpone cutting the pavement until the intended third party has acquired a permit from the City to perform the required restoration work. Special Conditions Page 8 of 8 w a i a VERIZON LEGEND IIIIIIIII0 IIIIIIIII PL FDH.288 PL FDH 288 HANDHOLE ASSEMBLY 36"X36"X36"- M#11022806 PL.250 GROUND PL 1-4" PVC - 50' ENV 3-1.25" SD ' 140' OW OW _ 50' W-E -, F iV C1V 1 s� CALLE TEMECULA 8 M T (p T OJ � T F CF— ow _ ROW } 6' LL LL U U 18' rY • Q U - °z J O J le Q U 1 7U l I =07 i A1iILI OBORE PIT QFIBER CALLOUT REFERENCE El HHIMH CALLOUT REFERENCE SUBDUCT CALLOUT REFERENCE TERMINAL CALLOUT REFERENCE FIBER DISTRIBUTION HUB (FOH) ❑ NEW HANDHOLE ® NEW MANHOLE / - SLACK I STORAGE LOOP III GROUND ROD 25ohm Q CABLE IN CONDUIT AERIAL —� POLE ANCHOR ® POLE DOWN GUY RISER DETAIL GENERAL ® PROPERTY ADDRESS ® SPLICE PROPOSED RUNNING LINE 'FDH BOUNDARY —CF— CURB PACE —EOP— EDGE OF PAVEMENT —FIL— FENCE LINE ---- RIGHT OF WAY GUARDRAIL —COM— COMMUNICATIONS LINE —DRN— STORM DRAIN LINE —GAS— GAS LINE —PWR— POWER LINE —SAN— SANITARY SEWER LINE —WTR— WATER LINE RAILROAD TRACKS CENTER LINE 1mwNnt Naticn e.ouw utivutT a tN op.«mw,t Ieep tpulm D Dlp AMd le.,entstlpn My It w a' M Im�O lnlalp -Pw„11t a u..t.- wtn w..11d Pw Den pp Mgt L. Mv,nMr-1 underground SeMro Alert D a^ cq � s centTaoo-aaTasoo U-. D nn volaoR ARnu eTATe1 CALIFORNIA DIWgq TMD1111e WIDBP Po.#.879 Grid#:F3 LA QUINTA Yrele 191TD14 �, LA QUINTA 054 ay1 PJ M B SHOP TAFAO Dnte 0713110s DeegweDen 7FFAOAF en JIM BISHOP — 07131106 - TRW COuM OF RIVERSIDE ERCROACWO PERMIT PTTP PgEft OIOT. ROVTL' ` VERI•ZON LEGEND BURIED PLANT .�ecroser�a BORE PIT O ALL WMAPPLrtSBLaSCROJ® OUT — ^'—'•• FIBER CALLOUT REFERENCE Q f 7NnmaaaemCa PANYMWdwurRrAr7v1•F� 7oe�mrLPumANDSHONVA•cIV13XV WMMWrYPOSCOIPAN.00MMOr PRELU=ANPOr12RpAWYMUC71MMAN"WV=A"&-" - .24 5"�W/DTH -•. ----' .-. -. otTARANre71MREARAMOo7HENMAdTRMMIXE I PAULMEOFTIMCOMPANY TOADWML N O HH/MH CALLOUT REFERENCE SIWFRUCTUAEJ Of 7r®I COM OVI LOCATION WILL NOr OA RAJM FORA CLAM PORAITRA tIOMAND TFdeawrNAetownuuraNaLemaAULwrAo�Toa�erRtxnal>®wrmnmoroNNaw %� SUBDUCT CALLOUT REFERENCE tRDr �oJ WP ALL IIDRK SMALLCO7077MLATOr1'MIDNOPVM*rAMMAMS.=S R=TW MRPLIRLWWORKS `TERMINAL CALLOUT REFERENCE AMP SUPP&Z ENTS TMT G O(AFWA04 OR�AND 70 NO ETAMTAID PLANMAID MACCONCATIONSOF TaeIMTM7RBdIlEeTOwOPlrMLe WIOMD. - ftELDAlNMONEfOfMDCR CRCOUN7YJWVMMWCUISF DL"MDXMMDSMALLJEOIAWA77NB JfQ7MM OF FIBER DISTRIBUTION HUB (FDH) • THE Cflr ORCaMrrCOMSTRRCTNMI RIWEL'IOIL ❑ NEW HANDHOLE ALL NHNCDNfROCMON(AIDAROYE OMOtOOAPPU1M04MCFD)JMALL CONFORM, TO C/TYINm COLORrl'RAIO/DAND " ddorvmraN otmIONANDEA O NEW MANHOLE COA@rAR71ON NOMOSARMUU MIOMMYN M MOLMC770A LIAIONUM OPmOfIOOr OPEN TAENCTArA ' TMMAND WOO HOWM CrWIEHOOOANAfM&WA%tOUAWALLM40MALA MAAIDIM4WCMC?r SC SLACK/STORAGE LOOP DT �� 42"HE/GHT OP��������� OXIALlIffrAL400144affONCTTYSTSMITM CURRt40UTTIONANDSOINAf/m I GROUND ROD 25ohm TO FAennAYEAC EMP fOINTENDED LOCA7DNS OF MOAK THE CONTRACTOR MUSTAPRIPIORA . iIJOONAR7'NOFAMOAA PWOUr AWN THE CrY.CODr►ra PNMLC MORRIS DJWANnWff � - O CABLE IN CONDUIT rRAFM CON1ROL FLAMSAMALL REFMPARm AND JM Offrrm MR ANVURFAMPAPPROVm Mr TMC"PR:daTT AERIAL MMS7WIC7/OR 7RRFACR aN/TlmL PLANPEEPARATIOW GUOMIJ M& No COXNECUTIM aNTmaEerIDAM arALL lIB CDEm .A CWACr7t3oTFam CORTANrOL-ECT 46#fDURJaADVANWOF _ POLE ANCHOR A NOTPTAL.UFUJMW,OH®IRILISTRUC7URE'MOM AND 9flOOORCNDSENHCEALOrrff W342 •I7aa) 7WOIIOA DAYXFRMYD COSMTRtN:ITOM ® POLE .L ND7PrL.O`ALMWANDPOLL°DaAR7MUWM48IMMINARVAMWTDOOIR'Rf/C"RN' 20" DEPTH DOWN L MvtPr R7tOK 75 LBS, _NOURSONADVANCUOP r • DET � RISER DETAIL rL CDNYM"T MCRrAMASrATIdgJaNaBIM7WASYFffrYE 4VA" MfMtWr RECOMOPfld CALO•CrMALARORCOOVRATEDS4.M LOCALCOMTRUCXOMPEMMVDOMOTAMRf7708MMM E1Wfff. GENERAL wM7NADHWMMOLTUMEAUNrAMMEY ALL,M® PEDESTAL MOUNT area PROPERTY ADDRESS MP =L fRAFTvee dNMWa1 TOLdMAO?AR®ersTWaDR4 &'00erA0A �TTIyAgTG wa slEC'OMD Ow 7NE SPLICE O COOMMUCTIONANDANTEMAL UM01970 CI DORM MITI WUr VM=N 7ELETWdDCOMTS7EC04GtlIONS, '1441216 FDH . PROPOSED RUNNING LINE f& CONFRACTON71PurovrM4IOML'D PWMTOAMYEAtAVA"OA IPSWUTACRMEASULtHEMRDEVu7emE FDH BOUNDARY PEEroRNQRAPRoM fac"OMLENOMS MTdML NO7Or T607N/NE#MDEUMM Crmour oww" m COYTSVL"MYO07EADMP77MOeVLA770MWDLC)OUCrW MCASWCRREWDL 8MA12"OPENING —CF— CURB FACE 1f MA7#VLEAMWPCLi0XEVTVAEPAAfJDSMUHCOOUffFACMWff aSPRDdZS=AO/ 5" W/DTH PAD —EOP— EDGE OF PAVEMENT '12. P IEM49rMAJORMILMAND ON POLL SOMM 70MERL7ONAMMMU=aF=(S)aCMSOPC M&DmOR .24 .IN —F/L— FENCE LINE YID RAni GOP Ob00A1S1 AND OSP9111.E00010CA ---- RIGHT OF WAY fA AIAMOLMAIDFUL.RO®TDLIRRACOD70 VERQ BPUCT=MWLgfLXM07OAWM SM MON • DETADJ OSP 6225002404 AID OW 911-200610r& . GUARDRAIL fL QED".,, raCAMIM AND 8MIECK &BNOTRIS (ORAW TO CEZING)TO SHOMIX —COM— COMMUNICATIONS LINE fL nauiroaoeDNETIOfBHACE0OfA8f.71rJffioWRTTVRBOLNC1Mt7RAN'CEAwIDORgTVAfa W• —DRN— STORM DRAIN LINE sRawPvrtDMatN:►LamTYNea —GAS— GAS LINE fL SFYCS SOAISWMCMARR7DOIIm1R�NOLt'�dfMAM�ORNNCODfOf "dLL 1S —PNR— POWER LINE [COOPED ADrM FNOL. a Has —SAN— SANITARY SEWER LINE n. ••• ormmAMDAMTeafeQD rAtNe 7DRAvew NmvMDM arao•eOPtaeaawourrm aRADArD Law LOM tAn®ssF�vdam7meHas 42" HE/GHT42" —MINK— WATER LINE rL atmAM►ArARL WIDdl/WpOfIDMAlwnADYAETYS orsmfauaeq wN.m7oNu AAMIDI PVT OCt®To Too; !/MCOLLM YlaI►7TMPNpCM:D OTRlQQAOE ON AOMtOM. ❑ {--f—}�• RAILROAD TRACKS 1L .MMACOOVITANYQ SDI® cwMCAMOORaDm COVER (_ )ALurnNr TOMINIAMALArm —_— CENTER LINE a7RAVALJALDAA rAT3NvtwlDwrAMo7rDattoar W7mmeort9m7vERsatMFrwNruurrrar AYERAOL m MAImTIIALLOlA.7J/MRoOAtMrCMOLMANDmmer�-FOfrOMr,a;'rotrsj-ODers,AMD I,.F..e..rx.m. spPIORw•atler. coe..wu.,..aaweoruMla..00 uoon� r. Olma7� RATTAN/d1Cf1ATf DM7Ul� aUAMa 17MCMSf7RUCMOM/� 71M►MWfRO ' II DISSITOD CONDUIT WOL MODERN RAAARANOMLN►(RASS• LOFEN, ON M{AV7 TD/�TPNdv euAYNeaWOW 0I71IO1 JfMMNueTtom OR PROP" arMAMCRam MANINMLM ' ueeerBreRE ai. AN CLA4440M OF SIX MINC® ANAL EVMAafAIMERAJOM mew, ON AMMOVAND SIOatOO 20ADEPTH 80" MAd)RYCHAC (®TIOJtTa1DAf►UAr91m, 75.LBS. sL wLL RAdLLMs7MANOTTD JSMrewamLNrTN CASSLD GOMML07B/FMOP/EAC7ffises•raD.m'aDA . m eewrRAD•rIOR 7IO vem►AruemwAU ANDANr WALL 7DMmafauererraenamAMAMnmm"a _ . ArcArum®r7s m®AtLOA1m fo7TMMWMwrIDOI. . m ,��. �tLL,D�..M.M�MRa�.7DNADM�M7DD„�WRr-YD�LR PEDESTAL MOUNT PAD FOR FDH 144, 216, 288 & 432 CAB/NETS 9 •n. PLACE i•PDurNeonLeaWarDLnorm DUDramneATr9 m •MVUMU/MALL TIOCIUMMIS OPJ7tlQ COMM AMA. RA— 2161288 .FDH Call: 1•800227.2800 m RAND DW MOeNr IO eaLOWN aW IONNC[OaTD CAJON6 WIOM SANDMtMEM1 PROVIOVA r7OP9aCT MML AfJO7M �SO►CAt0T6 - tlP 31" W/D7M . m 7W�Ld0"/tS077®MImeZ Ct®A/d dOffd, SlC sf. IOWEOW aRM 7RMDM/DN JIAIPO CAJLLi JP{Pla (NAUrJEAJLTUADLOrA71ONa70JE - . OR7G�1®IV NONIIOM ORIICtOq COMYCRW lVYC100LpYC IpSAIRtSN<MIMOM OMPLITIPM '2L 48"NEIGNT _ - XL OAM® CAARMtLCED IN OPEN 71MO01 YNm RACEPRL WILL WAMGLMtgZL AMdaia OFrifLAW AXMIT TM r7MCAAaG7 MAMOOLTOAW7 10"4=(APWA). - - aL IIfM1mNTtN{SP'WIIOI7 to DDONDau7seARLEDmTrv►AND FLA®rr. CON►ACT - O MNOURa POMR70*rAA COIMTIWICMOIL 7AATfOMHNA.�� $ MORMER►ANm LAIDPGPOPD AAL RSALJRA®fO fIMY7IDLCI1l0YOA0/ERIr OW11ER OR Da11 R D �n EM OOYA®NfALAOCr. •- 20" DEPTH as AVwVNgMto eawPm 7D SPLN9MtA7TONOr 7TMtanwudMrrl. vaAOox AuIA elan • CALIFORNIA sT: roAMNAerDR wDt A>ararewMDAMA®aRaW7®Iwm aeu7nu7®J7NODMt PArAmN►rAMDq aR om9ax, lxorwe oume• Pg.#: 879 Grid#:F3 PA M EMMrMAA7UDM MO►RD{ACEMOTTSMYL RBDOE TO THE YfYFACHOM OF TNU D CWMraIYIOLVA'L rDMcvwurrOw !!Jr_LBB. . cln or coxTNOL xo. 'm RWOL®7/MCOIRAC70KDfYI�M RS MTV�"iCdr7WOL TRAAWWWOCAMONALL MLIORAfN•l®AHD ONAMr0 PIMLCAfONT#WArASDOQCW iMESrATACOUNTY. ON ^ - M7r. IOCALAUrMDTMECOSTMOD TOLMWLUOOINMA®PRIZZ LA QUINTA "INA Ca"TEM a1CMi NOIMRMAr Tff=W d"M PEDESTAL MOUNT m CONTRACTION SMALL MOAT COMIDWALDRAYAREPLACm MOIWA MMPWVV MAYrVERMOL 432 FDH LAQUINATA 0543 er JIM BISHOP 7PFAOBU _ AL PMEam TZ U NlNNYJSAAATO RADAONMDDwHNI j'JlaA'OTADRoo AMOw7 meMOm NM6 AtAz a • mxeoen oJIM 7FFAOAF en BiSXOP SCALE +ra 07I71106 N.T.S. Trt FDH Number COUNTY OFRIVERAIOE H4O19 ENCROACHMENT PERMIT " _ FTTF OBER DIST. ROUTE FWMT 4 OF 4 k � VERIZON LEGEND NAM ALL M07WAP►LVCML CAS OUT 1. TO7ELOIIONECOAPAWMMEMAJOnrTLYAr7lar®70 COMMEMYLOCATMAND MMIPA•L BDXTOO PUMMORESARD OTI ED MlBS71UC1fA® IN THE MCMOTY OF 7PM MDIOG NI TIDE COMPAMT W=No► OWRAlff="MWw NDO"=SLWTIQACIVAMB PAOOROaTpDDMrMNrroBNDWALL MIYMTMI/Cn4=MIMMRCCA=WrLOCATNMMRLA TERARAMSPWACLAM FMMXTMAMOMTAND TI M CO IMtCTC M SMALL MEREEPIDOOMBLEFORALL CAKAOO TO 81/39FIRI CTOIPX WNVnM SHOW 07 MOT. ALL wpM[SMALL CONFUSION To THE LAYMBrAMMM OF IrM BrAMOAAD XPECIIICA71010 FOR POMIC INDOOR AIM SUPPLEMENTS 711O ZM (A IMNAO.#ITEEMMUM AND TO IMO7AMMARD KAME AND MIECMCAVOMM OP ME WIN 71M OMCTOR OF P40MIC MOMIm PmD AIYIMMAD,TO TO H7Y ON COMBIT►ANVWMm COMMTRfR71100! ORARDp STILL LO MAOMAr TIOOYfCOTR 7ME CITTONCO&WITCOM127RUCIFIONpOECTaR. ALL ATWOWTFELOM I(ANVAMOMMORpGOAPFL4rfEAMCCVMALL � 70 CTYANDCOLOTYXOAEIDA ..a®MtAIM OmOIAMICaO COIIIIMTRYC7AINN MOINONARWRIAL MID OWAYM 08MLAWr TOA ALAOMUA OPROO POO7 CAN 7AEMCMATA 7MIEAND NOIhViWL=MMNTEEMOMWANANV4 0PALLgU M ALLOAMAVALQ MARWM WCMCr►Y BrRMrM CUWr OUr M4 AMD M NWALJL FOLLOIWM MOMPIC N CO/f/i1DM OFP42D COAMTRUCTION4 IFYIN TRACfO7 N7p►REAIOMMALLOM NO ALERT MAeO MADE ON CITY 87E MM CORM4 QU" MAND MDEMANR To PACMITATMACCEMN To DMrGm® LOCATidm OF WORK TMV COM/RAC70R NLCTAPPLYFORA TEM04ORANY NO PARWM PENIVI/FROM TOM Crr/A704ONT'M P9MMX WOODS OMTARIIREMMr. TRAFMC mIIrRDs PLANX MIA. a W PREPARED AND 8=07"ID FOR WI NLIIAND APIPRCMED BY TNM ertT7conMrs MMmTILPe7M0Pr71APv4caeDLrrleaaPLANPAEAARATTONOLImZLARs MOf11omMMBeLPTIMe BIm�C7MMLE MMLL raaDam X. COM7AC7 TFLEPMOMO ODMIRALWOOMECTUR48 01010101 MAOVANCM OFCOAM7RLAL7MN. s NDTPYALL U7M/T®.OTPRX BLW7RW7W8 LMERLI AND 94131130RONm 8EWAWALEMT(TdQ501T2l) Two MORMON DA/! PMOw To CVA77NucMML. .A. NOTIFY LOCAL PUNIAND PCILMS OEPAR/1MMTM 49 PNNpD ONAOVAMCE TO COMDfRUCT10M. A NOTFI OP AT ---IXKaWpA ANOM OP G01W71DIICTIOLL. 6 COMTRACTpT TO Of►ADP A SrwrB DMX10N OF IMMIM171OAA,"My EXCAVATION POWI;(X6 XXTO OF 7NX A - •14LAMO RCOME04TI9SF7z Lac" CMYTIMN:vwmpmRnrXDONOrLLQ►7MsjwwDMJLOLf. '7 CONTRACNMPQM/r TDBEOITMJWW MATALLmwA. •6 TRAR7CMCQNTIO. TO NMMAEMlIO®ITV XTNO7N4M RIOCAM , PLAT7A1WM AD OMTME POfdT. L . ODMXlIK7NSFAIMMATflOALLIMFDW 70 CONFINEW WIM MERMN TLANAMNCOMPANYSPECMA7100R ,0. CON7RACTORTOLAYOU►AtlMOLEV PwM17fOANrA=4VATXWMS10oMC MEE46LM� MOM =PIIM FEET OR ANNO FROM SECTION{O107NS AMDwq NOTIFY TEXAPPIOIQ< DILSFECTIOM. EXIMMEaOMD SMALL AO CORW14,71M TO DATAfOAB IF THE A6NATIOM MILL CONDUCT WFN CABLE ONCEM6 . ,,. A94MMEAM00RFLAADCLMTOSBFLACmNWRBCDNWRr/YC9ff. OM625422JIMa•OT. ,i NIBJRYALAIDOLWAND ORF40L RO>®TO AMSBr OMA AmMNlN OFMX(S7 MOM OF COARXB ROOTOR SAIM BANG OSP OaDWBBOPAND OSPB,,.mDONOCL IA ALANNLIIES AIM FULL BaLxX fDQBRAL7®mVQADN rOEY97G7rar1�@IOTIAAIISP SMOMN OrN DETAILS ONP 0320408AN AND aXP Bf1.fDOS1MCA - 14 COMPLETED WALL 7TOCEX2SS AND MAR OLD MECK AEI10710(DRAOM TO CMILOIQ) TO RS SHOWN, ,S. P94AM OI MOM TO HE PLACED omwnyBELOWPUTIOE DOLT 971FJLUCM AND OR OPPOSITE WALL PNp1 FUI USN pMrOIT RANCIL ,L M{PCM AGAIN MMCPwNA 70 OINM SO116 POLE OR MAOANLM MIT/ COMPLUTSMALL ME FAIIMPm NT N FfaL p GAME. ' A ALL QUITEXANOMM MMOP CAMM TO MYNA MBNO(O OFW-COMER mAN OOIIfEX 0=0 AND PLAW - AM LAOAEXM MpmPIZD OlTAM1�. IS, OF MLAWYAYARFA ARGON PAGrDSED MWOAD RAN/MS Ne7tmP PLACED, "ADDITIONAL ISOiTml 087 nCPB IV rMe MINIMUM! COMER MELAW TIRE PMpOaY OUIITIRGUM OQ PLOLILOAB ,L MIOIDOLOALOXO R MA�GYRCAOMGMDm COYEXlJoOg% MTiDAMLRLOOB4AYMr pTlRVAIBAlGOTOOC/AND ATAMYOTIMR roOW N® COMO O6inC SOSXGMTLALLYIwON AYEXA06 m rALmRawu/DenroRLMunramc ALAIm1aroN,l-Po1rLRler,a;•PDEapDGen�AND af-PaR�wer. 1M. Pn0S7OOVACAWbL4VrAMOM MOtEMBE OOw COYTI1I47M PED=MM MUSrM .K nQMOb COMaLDr MOLn9L/OStnLEXAA CWPMOPYBP."ONER WM AMA AILMIL IIAp9 C"EAIAACQPia•OTTOM n/O/MICRAS G/RO=ONTIANOELMro AMMANQi AIL AM�//OSARANCMd�(S)OMD®SMYL SBNAOMD�AXOY$SOLO�pMDIO1E.LND WITOD MWrMLCROIB LmMow MLATOICAf►MACMPImA .SL .ALL RAOIEXITMAPItrm EXnN•-'-"IPI7NCUN3o CWN'EXrfPmfOOP1uOIA.7taof[lear, Em m cDLLI1AerMr 7o vem►wwumwALL wAQGAwAu ronm wDLlerBrArX:rAAmLWAMLALL�IIa AMAMAIamnX TDBraco®IDTWEXARmrraor. .m A'ECORMAQaY MALLrowALa EXMMUIL�IrrspM.rTAWwOIMmrrrOOIrERAOrM1AlI01PL6 'A7. PLACV#T YlOPTOEX/NLROMOOLCram/f m MOAaLN/wALL 71OCo®l AtIm CANIOODML SE m AANa ORLLIItQY1DEXLOMM OAPpE®prO L'ASM0. IMQ OLMM6 M A� - MXYATBOTNLMMMOI/CAIMq. TRIENCHniro m TIQBmAmWIMRIOT®LDmE1T C1OSAND OUTQ. R7G r. IOO 00 OPOI TmMMPaR SLIMM CAM IA SIIN:X(ex 87 MAYBE RESIDUE LO-JTOMa To EX OMrIR�®B►YF>�N pSIFCrO14 COMrBACrDR TO MCMML SP"1®PTEA/rE17MLCGIOA eGMDLnm as CAMMOJIAO._GL/O4 aMN_:wLm LBS PEX roof.-� ML MARCHED CAMBMPLACID Of OPEN TmIC4 RAND IACOML MILL SEAOXptRM AMMURRBOFVACOW wlm,rAMGME TrWDABLAt f>Z�/BACIDO"TON7TN:,OObfO (YWAL - 'aA •Mnl®IIOIM/SCTaB fD COwWOANGBLOO6/MIXYA"o ILACt�If. CONTACT T PIO/AS PROM fDXTAR/DM WAA/MR7Ppt fO ammaLMMLAWOR . a6 MDMTEIPwIm LAAmACTPMLD MDL BXMDL"CED fD „W XATCFICTIOIOFP�Tf OI@Q 0070 BAMOILLNUITBE COPMATMNAL 77Pl=-1.4e-7RFNCN ,TYPICAL NANDHOLEPLACEMENT WIMLATERA" IN BmEP IAOI 77PiC4L FOR MAW muff"NO CONDWT COJI97311IC77ON MOTE ___I ... 13MA �rmmrlvlmr msNlooa Ir1A[bI10 /LOCArmYOOOY I'O0B mr®rAL Nws®IorAeorMM To .�� enoMmLLa N®..Ae.,m • A>mlwO DAC lOrO1®Ii COOfIIIw[f >d AMPAYONWroCOOofIfo MMIOTCA/MOIM ar ITN C7fauCUpIA. fMaOIY fDAIITM• IOR�IMMLAtLMPRNfTD LmralerMwenRIL D,.OAmr.IeAx....BaoMmr. - we®rm.eMMr®rsl�M.er. >7 CwTRIC7oR woe AlJIORBAMILWYO®MOTRRITRX OSYI[AAT9 STmOL0. MM0EMTMANmM40f RMl01MV�rMAAN>Q; MOr@Mw®7►MYLL NOOEX fO f1W YIIDM6MOM ty TO MRAOCOM{/Tf a CamTYpMDLMrB AL ff-AMrIOCM7IIACfDPrSID tITY1D PwOY�1RAlIIt CONIROLAANOWAOARD OMALL _ MYORwR1®AEX tINAN►OIT®I POALKf1ONf-0RWA►N ACTED XV 1IO S►wr4 COLDITY, OM LOCALAWYARMI T: 1TOCOXTMro EXOOCOomp//O SCPRK6 _ fAM/TD m CONTRACTOR SNALL ANNAI7 MOIMGw1i TIOrDWTIW Ir�� OGNORTAIM MMNAEX/YCni NDrmLD 7oEXPA0YOA9rrYJLmLt rA�IMr. wALDm r"me m wLLPWOOMRWNO/M0S1A®roLnLl/DOOM/TMw �•XCOA04EX OwOwLM LQOMO/m lTti .YIOr MAIL matom , OffrA& FOX ORDW EX/BT7ND CONDO? TYPACAL RIMER DErA& OF aL/Ap►rYroMMawa df fo AOdC►IfANOAm COLDIAeTs fYIMO/UTILP7Y ' w[LL YIMY - /T�� PROFILE PROPOSED MNMMLe PMOONDaT ITYPIAL VACOYiALOCATE DMA& saw I. LWBBnaI®mALaNas LB orpNm Lma 1TOWADpEXAN /NRAX 1•LDMG /RC t O"OGALWA TOO PwOYIDmF XIID TID PLACE �u.Pe-7umA" MDeN ovu mm SBTAO p ltA®ITITM RAFX IDDf NYT: FND GROUNDING DETAIL BOIPB PIT 6 NANDIIOLE PLAC01PA7r0MAIL (NIB) BURIED PLANT BORE PIT El ❑ NEW HANDHOLE FIBER CALLOUT REFERENCE MHlMH CALLOUT REFERENCE SUBDUCT CALLOUT REFERENCE TERMINAL CALLOUT REFERENCE FIBER DISTRIBUTION HUB (FDH) (M NEW MANHOLE Y SLACKISTORAGELOOP _JII GROUND ROD t 25ohm O CABLE IN CONDUIT AERIAL —Q POLE ANCHOR ® POLE +��,,- DOWN GUY -(jjj- RISER DETAIL GENERAL se eaPROPERTY ADDRESS QSPLICE PROPOSED RUNNING LINE FDH BOUNDARY -CF- CURB FACE -EOP- EDGE OF PAVEMENT -FIL- FENCE LINE ---- RIGHT OF WAY GUARDRAIL -COM- COMMUNICATIONS LINE -DRN- STORM DRAIN LINE -GAS- GAS LINE -PWR- POWER LINE -SAN- SANITARY SEWER LINE -WrR- WATER LINE }-�-f-} RAILROAD TRACKS --- CENTER LINE :aea..Tw..a a Me AI.t M.Inea.m. NmnMr to Oa IataaA OaMa 9atmit to erteavab' MO Oa TN6 Im ram OIP Alrt L0. NuvOar om CAII : CALIFORNIA OIVI9101O TNOWIO 6OIOeP Pg.#:879 Grid#:F3 CITY OF CONTROL NO, LA QUINTA tTMe ttNTelx MxcN, LA QUINTA 0543 O— eI PIJIM BIsNoP 714A0BU em, 071911o5 omlRNeo eY, 7FFAOAF en JIM BISHOP SCALE LIn•, 07131106 N.T.S. TT- FDH Number couNTr of RlveaBlDE H4019 ENCROACIOIENT PERMIT FTTP FIBER D18T. ROVIE aMMT 3 OF 4 +a , i i i r i H4019 SIZES 288 ' 15R I POLE/RI ER DETAIL LU POLE/ S, 1 9- PL 1-4 PVC-so� E/V I -LOV al� _w'.Z • � 1- R • w cv SEE HUB DETAIL ago SEE GENERAL NOS P908430D 2701. w _w CALLE TEMECULA 4b6,w-w 4bb'w-w 4661w-w 315'w-w-= :. 54525 54525 VAC x3 54552L 54520 VAC * 77643 PL M, 1-Lw $n f 54545 _ __ _: _ __ -jl�� __ �. V-AC r— 2'x3' _ z'x3' 54560 54565 r 54550 54555 54550 L. -j PL 54575 1 �. 54585 -� I-- . � —� � 1 54580 PL Law i-Lov sD 54580 - 54585 54560 54575 2'X3' � r� 54595 54600 54605 _ 54590 54580 54595 • 54625 -. VAC 54625 154600 .. _*54605� 54600 54605 i F.....� 54645 VAC. 54645 54620 54625 54620 54621 J L F -I f -1 Q � . 54665 A54660 •� � 54665 g 54640 � � 54645 ; � 54640 �- � 54645 L _j 2'X3' _ `1 PL W 14w a• 54685 54680 *,54685 54660 *54665 r 54680 - 54685 4 W PL 44' jp ■ 54700 VAC 54690 54685 54700 54711 L SP47io5-s. sn J LJ P<. ion 1-1. sn L J PL 1Q2' i L2S Sn F PL 44' F -LEI' Sn 1-" F 54725 1-LIB" n VAC 54725 54700 54735 0 * 54725 a PL 51, 1-1" n J 77620 W 2'X3' 150X20' a 45"-to" Of - 77500 VAC 77550 VAC W 54740 � � 54750 , > _ L J L J L J L d A W W CALLE POTRERQ,... - :. a 517'w-w 54765 77575 54755 VAC oe r� I? 77711 * VAC ' 2'X3' W EDC 77615 77655 � Q 77671 54780 54785 54770 w VAC . �z �. 54775 �.. , — > F .1�' t 54840 f 54510 54515 � ,. 54530 -54535-- 54550 54555 ® P988520 VAC VAC 54595 54622 54615 P98853D r 54625 54646 54645 P93140D 54660 54665 •1 54700 VAC P931330 54722 54710 L 54740 VAC J s DETAIL POLE/RISER DETAIL i 326' 77705 F o� �. 77725 i _ 54540 VAC 54550 P93007D 54565 cl FARTHEST 54638 1 54585 TERMINAL 2,687 KFT a L VAC i w 7 C3 P98008D V� W 54625 Z J i W 54640 54655 > d 54685 i 54700 PGT74341) 54711 54740 L J . �, 1-LES' sn 1 Lw sa CIE- 54805 54805 54780 54795 r 54800 54795 VAC59 54820 f P906604D 54825 54820 J 54825 54800 VAC 54820. 54805 _A J VAC 1 L In � - � PL 441" 54845 54840 g 54845 v 54820 54815 54840 54835 54845 L k J L 54830 PL 44' PL 44' r Q`C 1- 54840 54835 F VAC 54865 54860 � 54865 i-'.es' s�° 54860- PL s1' 1-L23' sn L VAC '� r P R 54885 54880 54850 54855 S.:5488Q 548 55- L. .J ,, . J L N ...j PL s1' 1-um" L J 54881 � f D —I -1 fi 54941 J 54905 a 54900 fa 54860 54865 ra 54900 54905 , 19 SD .: 54925 54880 54925 4 1. t PL 51' 1-123' sa 54925 T 54940 54945 54945 r 54920 Z 54945 A&B L, PL 108' 1-LP'3• sa L,� a �------ 2 1s�x20• 54965 ' _ �' VAC > 54950 __j { 77600 54965 J 15'X20' 15'x20• 54965 I, 54985 77500 54985 L J L. J L. J Ldp r CAWS TECATE LEGEND ❑ MAWOLE �] PROPOSED HANDHOLES 0)0 FMH LOCATION (25 OHMS GROlM) 0 FIDER TERMINAL DE'MARK (PROTECTOR) J L.MOP FEED / STOP INDICATOR ® EXISTING PEDESTAL UV ) DME PIT X JOINT POLE VIRTUAL MULTI DWELLING UNIT N. 0L�S. 1. CONDUIT SHALL BE PLACED AT A MINIMUM DEPTH OF 30 INCHES. 2. SEAL ENDS OF ALL CONUIT PLACED. 3. ALL CONDUITS PLACED WILL BE PROVISIONED WITH A TONEABLE "MULE TAPE". 4. "MULE TAPE" TO BE BONDED AND GROUND EVERY 1000 FEET OR LESS. 5. FOLLOW ALL VERIZON BONDING AND GROUNDING PROCEDURES. 6. COIL FIBER AT TERMINAL AND SPLICE LOCATIONS AS PER M&P. 7. THIS DRAWING WAS DESIGNED AS PER M&P V1.5 8. ALL HANDHOLES ARE 17" X 30" UNLESS OTHERWISE SHOWN 9. FEEDER CABLE TO BE PLACED BY FEEDER WO # 7FFAOAF 10.ALL PROTECTORS ARE LOCATED AT THE BACK OF THE HOUSES i STREET TYPICAL CALLE PORTRERO AVENIDA RAMIREZ AVENIDA CARRANZA AVENIDA VALLEJO ROW - - - - -- — EOP � $36' 60' EOP ROW NOTE: NO SIDEWALKS OR PARKWAYS STREET TYPICAL AVENIDA VELASCO CALLE TEMECULA AVENIDA HERRERA ROW -- -- -- -- -- EOP 36" 60' EOP ROW NOTE: NO SIDEWALKS OR PARKWAYS QUIn PHASE IIII CONDUIT DRAWING VERIZON a _- r wrrrs wow mommam -rs� r,ar..rrrr -am- 6"-_= p W 000MW ovm 4•a.._ =�� VERIZON AREA: SOUTHERN CA WIRE CENTER NAME: LA QUINTA W.C.#:0543 EXCH CODE: RMT. CODE: I WO #. 7PFAOeU RELATED WO #: 7FFAOAF CONTROL #: WO TITLE: 0543-7PFAOBU-H4019 TAX DST: TWP: I RNG: SEC: SAL: FILE: REV # REV. DATE: REASON FOR CHANGE ENGR: QC'D: CADD: p 1 �la3 alo DRWG BY: PAUL SAYSON ENGR & OFC PH #: APRVD: DATE: 8/17/06 SCALE: NTS PRINT # 1 OF 2 i