12-0933 (RER)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 12-00000933
Property Address: 80055 MERION
APN: 762-191-010- - -
Application description: REMODEL - RESIDENTIAL
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 11000
Tityl °F 4Q"
Applicant: Architect or Engineer:
------------------
LICENSED CONTRACTOR'S DECLARATION
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
I hereby affirm under penalty of perj y th 1 am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the usines and Professionals Code, and my License is in full force and effect.
Licensee Class: 1B License No.: 594043
Date: I ^ I' Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
{ _) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed',
pursuant to the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 9/05/12
Owner:
CREIGHTON, SCOTT F.
80-055 MERION
LA QUINTA, CA 92253_
lu
'E
Contractor: 1I1 s �w=,:, r /s lluu�
7C'S CONSTRUCTION be MAIN'it'-(
48236 VISTA DE NODAL§
LA QUINTA, CA 922�3 L 66� e a 0i 4TA
(760) 564-5811 FINANCE DEPT._.-.- ---,-..
Lic. No.: 594043
•----------------------------------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 0028211-2011
_ 1 certify that, in the perfor of the work for which this permit is issued, I shall not employ any
person in any manner o as t become subject to the workers' compensation laws of California,
and agree that, if, I s ould be ome subject to the workers' compensation provisions of Section
(� 3700 of the Labor ode, I all fo it comp
comply with those provisions.
Date: 1 ^ ^��'�'Applicant:
WARNING: FAILURE TO SECURE ORKE COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL P ALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quints, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that th bove formation is correct. 1 agree to comply with all
city and county ordinances and state laws relating to bui ing co tructi ,and hereby authorize representatives
of,this county to enter pon the above -mentioned prop y for ' pecti purposes.
Date: �' ^ Signature (Applicant or Agent):
i'.
Application Number . . . . . 12-00000933
------ Structure Information EXISTING SFD -----
Construction Type . . . . . TYPE V, UNPROTECTED
Occupancy Type DWELLG/LODGING/CONG <=10
Other struct info . . . . . CODE EDITION 2010
----------------------------------------------------------------------------
Permit . . . BUILDING PERMIT
Additional desc . .
Permit Fee . . . . 126.00 Plan Check Fee 81.90
Issue Date . . . . Valuation . . . 11000
Expiration Date . . 3/04/13
Qty Unit Charge Per Extension
BASE FEE 45.00
9.00 9.0000 THOU BLDG 2,001-25,000 81.00
----------------------------------------------------------------------------
Special Notes and Comments
INTERIOR ENTRY AREA REMODEL; REPLACE
LIVING ROOM SL.GL. DRS. PER ENGINEERED
PLANS. ARCHITECT: CHARLES GARLAND C11991
2010 CODES.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00
ENERGY REVIEW FEE 8.19
HOURLY PLAN CHECK 87.50
STRONG MOTION (SMI) - RES 1.10
Fee summary Charged
Permit Fee Total 126.00
Plan Check Total 81.90
Other Fee Total 97.79
Grand Total 305.69
Paid Credited Due
.00 .00 126.00
.00 .00 81.90
.00 .00 97.79
.00 .00 305.69
LQPERMIT
DIII 1f
City of La Quinta
Building &I Safety Division
Permit # ��
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
I2�
Building Permit APPlication and Tracking Sheet
X
Project Address:,. �5 �Q s
1V
-ner's Name:
A. P. Number: �y
I�'
7 Address:
Legal Description:
z/
City, ST, Zip:
�%7iZs
V07—A I �
Contractor:
elephone:
Address.
Project Description -
City? ST, Zip:
n�tS I N
Telephone:
�C
State Lic. # :
-- C� —� ID A—u.
Arch., Engr., Designer:
City Lic. #:
!��g � S7. �1 O
Address: o•, SV
City, ST, Zip:
ZZ
Telephoner
Construction Type:
State Lic. #:
Occupancy:
Name of Contact Person:
Project type (circle one): New Add'n Ite Repair Demo
C_L Sq. Ft.: # Stories: # Units:
Telephone # of Contact Person: � �A!
Estimated Value of Project: I t3�7
APPLICANT: DO NOT WRITE BELOW THIS LINE
# Submittal
Req'd Rec'd TRACKING
Plan Sets
�y PERMIT FEES
3 Plan Check submitted b 1 r
Structural Calcs.
_
lw+ Item Amount
� Reviewed, ready for corrections
Truss Calcs.
Plan Check7Deposit
Called Contact Person
Plan Check Balance
Title 24 Calcs.
'Z� Plans picked up
Flood plain plan
Construction
Plans resubmitted
Grading plan
- Mechanical
2"d Review, read}' for correction issue
Subcontactor List
] Electrical
Called Contact Person
Grant Deed
Plumbing
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
3" Review, ready for corrections/issue Developer Impact Fee
Planning Approval
Called Contact Person
Pub. Wks. Appr
A.I.P.P.
Date of permit issue
School Fees
Total Permit Fees I 3p_'�F.
.,Pin I l -'5 , 17.
SEP/06/2012/THU 03:53 PM The Monarch Group FAX No,760 776 5111 F.001
FCA. WEST II RESIDENTIAL ASSOCIATION, INC.
39755 BERKEY DRIVE ST'E ,A,
PALM DESERT, CA 92211
PHONE (760) 776-5100 - FAX (760) 776-5111
August 17, 2012
Mr. Scott Creighton
31 Fieldway Rd.
Toronto, Ontario
Canada M8Z 31-4
Reference: 80-055 Merlon, La Quinta, CA
Architectural [Mange Request — Pocket Window/Door Column and Pony Wall
removal.
Dear Scott Creighton:
The Architectural Committee met on August ' 16, 2012 .and reviewed and approved your
architectural plans for a Pocket Window/Door Column and Pony Wall removal.
All other Architectural Rules & Regulations of PGA WEST II Residential Association dated
Revised 8/1/07 pertain.
■ A Maintenance Agreement will be required, one will be sent to you tear proper execution
as soon as it is prepared by counsel.
Your contractor must meet with Bob Pantanella, Director of Community Services prior to
commencing any work so they are aware of access, parking and other regulations of the
Association, Mr. Pantanella's phone numbers is 760-564-1032.
• Review Gar the Cbinnt ttee Is only for ,al con%rrrrarice with
Arclsitedurel Rules ..f#}s, ft of Me owner to holly undgrstanef
nrJ rrrnf(M W the Anftffiectural +EQi{!kw c7feria whether or not a1I deficr`encies
Brie noted &tjgg yiew� It is also Me ownel's f7rll resotv field rreri�
all exisrino Condltlons The o refs deglsslon with =dt d to or root
desl n o4if be . Please reefer to the Ar9►sil
' l ales for all r ui
sudmdtlals.
Please contact Luis Umana, Sunshine Landscape at 760/346-3999 and Joanne Rose, the
Association Manager, prior to any irrigation modifications associated with this change. Damage
to landscaping, i.e. shrubs, trees, flowers and turf is the responsibility of the contractor. The
original landscaping must be brought back to its original condition when the project Is completed.
Your contractor must schedule a meeting with Bob Pantanella, Director of Community Services
prior to commencing any work to review the Rules of the Master Association and Rules relating to
Res II regarding construction activity. Mr. Pantanella's phone number is 760/564-1032.
Approvals given by the Architectural Committee are good 'foes• only six months from the date
on the approval letter. If construction has not commenced withln six months after the project
approval date, a new application must he submitted.
SEP/06/2012/THU 03:54 PM The Monarch Group FAX No. 760 776 5111 P.002
Page .0
PGA WEST H Residential Association
Architectural/Creighton 8.16.12
Upon completion of your project, please complete and return 'Me Notice of Completion of
ArchRectural Change.
For additional information or questions, the Board has directed that you contact ]oanne Rose,
CaCAM, Association Manager, at 7601776-5100, Ext. 320. -
Sincerely,
PGA WEST H Residential Association
Joanne Rose, CCAM Manager for the
Architectural Committee
Cc: unit
Arch
I BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
7 C's Construction
80-055 Merion
La Quinta, CA
Project Designer:
Lench Design Studio
78215 Calle Cadiz
La Quinta, Ca 92253
760-564-1860
Report Prepared by:
Joan D. Hacker
Insu-form, Inc.
77810 Las Montanas Road, Suite 201
t4 Palm Desert, Ca 92211
760-345-1352
C1-TY OF LA EQTU`NTA
BUILDING & SA Y
APPROVED
FOR CONSTRUCTION
L2 Bar
Job Number:
RF` ��IVED
Date:
AUG 16 2012 8/16/2012
ThePro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 51 by EnergySoft User Number.' 2655 RunCode: 2012-08-16T10:20:18 ID:
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF-1 R Certificate of Compliance 3
Form MF-1 R Mandatory Measures Summary 9
HVAC System Heating and Cooling Loads Summary 12
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF-1 R
Project Name
7 Cs Construction
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
811612012
Project Address
80-055 Merion La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,355
Addition
0
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes IZI No HERS Measures -- If Yes, A CF-413 must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity ( Features (see Part 2 of 5) Status
Slab Unheated Slab -on -Grade None 3,355 Perim = 120' Existing
Wall Wood Framed R-11 1,300 Existing
Roof Wood Framed Attic R-19 3,355 Existing
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Front (NW) 87.9 0.710 0.73 2.0 none Bug Screen
Existing
Left (NE) 158.5 0.710 0.73 2.0 none Bug Screen
Existing
Rear (SE) 216.1 0.710 0.73 2.0 none Bug Screen
Existing
Rear (SE) 112.0 0.710 0.73 2.0 none Bug Screen
Removed
Rear (SE) 136.0 0.590 0.45 2.0 none Bug Screen
New
Right (SW) 1912 0.710 0.73 2.0 none Bug Screen
Existing
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
2 Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnergyPro 5.1 by EnerigySoft User Number: 2655 Run Code: 2012.0846T10:20:18 ID:
Page 3 of 12
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R
Project Name Building Type ® Single Family ❑ Addition Alone
7 Cs Construction ❑ Multi Family 0 Existing+ Addition/Alteration
Date
8/16/2012
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form for each of the measures listed below for final to be given.
EneravPro 5.1 by EneravSoft User Number.' 2655 RunCode: 2012-08-16T10:20:18 ID: Pace 4 of 12
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
7 Cs Construction
❑ Multi Family m Existing+ Addition/Alteration
811612012
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV (kBtu/ft2- r)
Space Heating 4.78 4.98 -0.20
Space Cooling 132.47 130.35 2.12
Fans 2853 28.06 0.47
Domestic Hot Water 12.18 12.18 0.00
Pumps 0.00 0.00 0.00
Totals 177.96 175.57 2.39
Percent Better Than Standard: 1 3
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (NVV) 315deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (NVt7 590 88
Fuel Available at Site: Natural Gas (NE) 450 159
Raised Floor Area: 0 (SE) 600 352
Slab on Grade Area: 3,355 (SK9 450 191
Average Ceiling Height: 10.0 Roof 3,355 0
Fenestration Average U-Factor: 0.69 TOTAL: 790
Average SHGC: 0.68 Fenestration/CFA Ratio: 23 5
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Insu-form, Inc.
8 620i
Address 77810 Las Montanas Road, Suite 201 Name Joan D. Hacker
Citv/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 5i n Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building enve)ope sealing require
.installer testing and certification and field verification by an approved HERS rater. -+
Designer or Owner (per Business & Professions Code)
Company Lench Design Studio
Address 78215 Calle Cadiz Name
City/State/Zip La Quinta, Ca 92253 Phone 760-564-166.0 fined � icense'#. Date
EnerovPro 5.1 by Ener vSoft User Number: 2655 Run Code: 2012-08-16T10:20:18 ID: Page 5 of 12
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R
Project Name Building Type m Single Family ❑ Addition Alone
7 Cs Construction l ❑ Multi Family 10 Existing+ Addition/Alteration
Date
1811612012
OPAQUE SURFACE
DETAILS
Surface
Type
Area
U-
Factor
Insulation
Azm
Tilt
Status
Joint Appendix
4
Location/Comments
Cavity
Exterior
Frame
Interior
Frame
Slab
3.355
0.730
None
0 180
Existing
.4.4-7-A1
Existing Living
Wall
502
0.110
R-11
315
90
Existing
4.3A-A2
Existing Living
Wall
292
0.110
R-11
45
90
Existing
.4.3.1-A2
Existing Living
Wall
248
0.110
R-11
135
90
Existing
4.3.1-A2
Existing Living
Wall
259
0.110
.13-11
225
901
Existing
.4.3.1-A2
Existing Living
Roof
3,355
0.049
R-19
315
0 Existin
-4.2.1-A4
Existing Living
FENESTRATION
SURFACE
DETAILS
ID
Type
Area
U-Factorl
SHGC
Azm
Status
Glazing Type
Location/Comments
1
Window
21.01
0.710
Default
0.73
Default
315
Existing Double
Metal Clear
Existing Living
2
Window
22.0
0.710
Default
0.73
Default
315
Existing Double
Metal Clear
Existing Living
3
'Window
18.8
0.710
Default
0.73
Default
315
Existing Double
Metal Clear
Existina Livin
4
Window
261
0.710
Default
0.73
Default
315
Existing Double
Metal Clear
Existing Living
5
Window
21.0
0.710
Default
0.73
Default
45
Existing Double
Metal Clear
Existing Living
6
Window
10-0
0.710
Default
0.73
Default
45
Existing Double
Metal Clear
Existing Living
7
Window
64.0
0.710
Default
0.73
Default
45rExisting
Double
Metal Clear
ExistingLivinq
8
Window
36.0
0.710
Default
0.73
Default
45Double
Metal Clear
Existing Living
9
Window
27.5
0.710
Default
0.73
Default
45Double
Metal Clear
Existing Living
10
Window
64.0
0.710
Default
0.73
Default
135Double
Metal Clear
Existing Living
11
Window
96-0
0.710
Default
0.73
Default
135Double
Metal Clear
Existing Living
12
Window
15.0
0.710
Default
0.73
Default
135Double
Metal Clear
Existing Living
13
Window
16.0
0.710
Default
0.73
Default
135
Existing Double
Metal Clear
Existing Living
14
Window
48.0
0.710
Default
0.73
Default
135
Removed Double
Metal Clear
Existing Living
15
Window
64.0
0.710
Default
0.73
Default
1351
Removed I Double
Metal Clear
Existing Living
16
Window
25-1
0.710
Default
0.73
Default
1351
Existing I Double
Metal Clear
Existing Living
(1) U-Factor Type: i i6-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC T 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR
SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
Ove hang
Left Fin
Right Fin
H t
Wd
Len
I Hq t
LExt
I RExt
Dist
Len
H t
Dist
Len
H t
1
Bug Screen
0.76
3.5
3.0
2.0
0.1
2.0
2.0
2
Bug Screen
0.76
3.5
3.0
2.0
0.1
2-0
2.0
3
Bug Screen
0.76
3.5
3.0
2.0
0.1
2.0
2.0
4
Bug Screen
0.76
3.5
3.0
2.0
0.1
2.0
2.0
5
Bug Screen
0.76
3.5
3.0
2.0
0-1
2-0
2.0
6
Bu Screen
0.76
3,5,
3.0
2.0
0.1
2.0
2.0
7
Bug Screen
0.76
8,01
8,0
2.0
0-1
2.01
2.0
8
Bug Screen
0.76
a 5
3.0
2.0
0.1
2.0
2.0
9
Buo Screen
0.76
3.5
3.0
2.0
0.1
2.0
2.0
10
Bug Screen
0.76
8.0
8.0
2.0
0.1
2.0
2.0
11
Bug Screen
0.76
8.0
12.0
2.0
0.1
2.0
2.0
12
Bua Screen
0.761
3.5
3.0
2.0
0.1
2.0
2.0
13
Bug Screen 1
0.761
3.5
3.0
20
0.1
2.0
2.0
14
Bug Screen
0.76
8.0
6.0
2.0
0.1
2.0
2.0
15
.Bu Screen
0.76
8.0
8.0
2.0
0.1
2.0
2.0
16
.Bu Screen
0.76
3.5
3.0
2.0
O. 11
2.01
2.0
EnergyPro 5.1 by FnergySoft User Number. 2655 RunCode: 2012-08-16T10:20.18 ID. Pa e 6 of 12
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R
Project Name
7 Cs Construction
Building Type m Single Family ❑ Addition Alone Date
❑ Multi Family 10 Existing+ Addition/Alteration 1811612012
OPAQUE SURFACE
DETAILS
Surface
Type
Area
U-
Factor
Insulation
Azm
Tilt
Status
Joint Appendix
4
Location/Comments
Cavity
Exterior
Frame
Interior
Frame
FENESTRATION
SURFACE
DETAILS
ID
Type
Area
U-Factor
SHGC
Azm
Status
Glazing Type
Location/Comments
17
Window
136.0
0.590
NFRC
0.45
NFRC
135
New IWC
6200 Alum/Low-E
Existing Living
18
Window
48.0
0.710
Default
0.73
Default
225
Existing Double
Metal Clear
Existing Living
19
Window
30.0
0.710
Default
0.73
Default
225
Existing Double
Metal Clear
Existing Living
20
Window
14.0
0.710
Default
0.73
Default
225
Existing Double
Metal Clear
Existing Living
21
Window
27.51
0.710
Default
0.73
Default
225
Existing Double
Metal Clear
Existing Living
22
Window
26.7
0. 7101
Default
0.73
Default
225
Existing Double
Metal Clear
Existing Living
23
Window
30.0
0.710
Default
0.73
Default
225
Existing Double
Metal Clear
Existing Living
24
Window
9.0
0.710
Default
0.73
Default
225
Existing Double
Metal Clear
Existing Living
25
Window
6.0
0 710
Default
0.73
Default
225
Existing Double
Metal Clear
Existing oving
(1) U-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR
SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
Ove hang
Left Fin
Right Fin
Hat I
Wd
Len
H t
LExt
REM
Dist
Len
H t
Dist
Len
H t
17
Bug Screen
0.76
8.01
5.0
2.0
0.1
2.0
2.0
18
Bug Screen
0.76
6.01
4.0
2.0
0.1
2.0
2.0
19
Bug Screen
0.76
3.5
3.0
2.0
0.1
2.0
2.0
20
Bug Screen
0.76
3.5
3.0
2.0
0.1
2.0
2.0
21
Bug Screen
0.76
3.5
3.0
2.0
0.1
2.0
2.0
22
Bug Screen
0.76
3.5
3.01
2.01
0.1
2.0
2.0
23
Bug Screen
0.76
3.5
3.0
2.01
0A
2.0
2.0
24
Bug Screen
0.76
3.5
3.0
2-01
0,1
2.0
2.0
25
8ua Screen
0.76
3.5
3.0
2.0
0.1
2.0
2.0
EnergyPro 5.1 by Ener ySoft User Number: 2655 RunCode: 2012-08-16T10:20:18 ID: Page 7 of 12
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R
Project Name Building Type ❑ Single Family ❑ Addition Alone
7 Cs Construction ❑ Multi Family 0 Existing+ Addition/Alteration
Date
811612012
BUILDING ZONE INFORMATION
System Name
Zone Name
Floor Area ft
Volume
Year Built
New
Existing
Altered
Removed
Living Zone Existing
Living
3,355
33,550
1978
Totals
01
3,3551
01
0
HVAC SYSTEMS
Svstem Name
Qty.
Heating Type
Min. Eff,
Cooling Type
Min. Eff.
Thermostat Type
Status
Living Zone
2
Central Furnace
78% AFUE
Split Air Conditioner
12. 0 SEER
Setback
Existing
HVAC DISTRIBUTION
System Name
Heating
Cooling
Duct Location
Duct
R-Value
Ducts
Tested?
Status
Living Zone Ducted
Ducted
Attic, Ceiling Ins, vented
4.2
❑
Existing
El
WATER HEATING SYSTEMS
System Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE I
Standby
Loss or
Pilot
Ext.
Tank
Insul. R
Value Status
Standard Gas 50 gal or Le:1
1
Small Gas No
Pipe Insulation
40,000
50
0.53
n/a
n/a Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
C:
0
i�
Q —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty.
HP
Plenum
Outside
Buried
EnergyPro 5.1 by En ergySaft User Number: 2655 Run Co de: 2012-08-16'r10.20.18 ID: Page 8of 12
MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF-1 R
Project Name Date
7 Cs Construction 1 811612012
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF-
1 R-ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R
Form with plans.
Building Envelope Measures:
116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-11 1 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118 a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF-1 R Form.
* 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U-factor.
150 b : Loose fill insulation shall conform with manufacturer's installed design labeled R-Value.
* 150 c : Minimum R-13 insulation in wood -frame wall orequivalent U-factor.
* 150 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U-factor.
150 f : Air retarding wrap is tested, labeled and installed according to ASTM E1677-95 2000 when s ecified on the CF-1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(I): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no qreater than 2.0 permAnch and shall be p.rigacted from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1A: Mason or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the buildin , are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve l ackftow prevenflon, pump isolation valve and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150 h : Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150 i : Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A; Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water p1pes ate insulated per Standards Table 150-B.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150 ' 3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150 ' 4: Solar water -heating systems and/or collectors are certified by. the Solar Rating and Certification Corporafion.
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-08-16T10:20:18 ID: Page 9 of 12
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R
Project Name Date
7 Cs Construction 811612012
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CIVIC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such toe is used in combination with mastic and draw bands.
150 m 7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on -off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating or a pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114 b 2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150(p): Residential pools stems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150 k 3: The watta a of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150 k 7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-08-16T10:20:18 ID: Page 10 of 12
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3) MF-1 R
Project Name
Date
7 Cs Construction
811612012
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150(k)11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceilin .
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1. Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion senso' ,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system ,'EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, o+ other location subject to Article 680 of the California Electric Code need not
be high eff icacy luminaires.
§150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined accordin to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of §119.
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2012-08-16T10:20:18 ID. Page 11 of 12
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
7 C's Construction
Date
8/16/2012
System Name
Living Zone
Floor Area
3,355
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total ROOM Loads 2,454
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent 1.
CFM
Sensible
Output per System
70,000
62,784
3,170
990
50,591
Total Output Btuh
140,000
0
Output Btuh/s ft
41.7
5,324
3,594
Cooling System
0
0
Output per System
46,000
0
0
0
0
Total Output Btuh
92,000
0
3,170
0
Total Out ut Tons
7.7
1 5,324
3,594
Total Output Btuh/s ft)
27.4
Total Out ut s ft/Ton
437.6
73,431
1 57,780
Air System
CFM per System
1,300
HVAC EQUIPMENT SELECTION
Airflow cfm
2,600
Existing HVAC
77,170
391
140,000
Airflow cfm/s ft
077
Airflow cfm/Ton
339.1
Outside Air (%)
0.0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
1 TIME OF SYSTEM PEAK
1 77,1701
391
140,000
I Jan 1 AM
Outside Air cfm/s ft)
0.00
Note: values above given at ARI conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating
Peak)
26 OF 69 OF 69 OF 119 OF
■
Outside Air
0 cfm Supply Fan Heating Coil
2,600 cfm
69 IF
118 IF
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78OF 80/62IF 80/62OF 52/51OF
Outside Air
0 cfm Supply Fan Cooling Coil
2,600 cfm
80 / 62 IF
III
54) 51 IF
37.5 % ROOM
78 f 6
EnergyPro 5.1 by EnergySoft
User Number: 2655 Run Code: 2012-08-16T10:20:18
ID: Page 12 of 12