BSIG2018-002178-495 CALLE'TAMPICO .i VOICE (760).777-7125
. Ct� U
LA QUINTA, CALIFORNIA 92253' DESIGN & DEVELOPMENT DEPARTMENT
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 7/18/2018
Permit Type/Subtype: SIGN/ Owner:
Application Number: BSIG2018-0021 MAUREEN SHARPE
Property Address: 79174 HIGHWAY 111 101 3025 HIGHLAND PARKWAY #350
APN: 600390029 DOWNERS GROVE, IL 60515
Application Description: CHIPOTLE / REPLACE EXISTING.SIGNS
Property Zoning:
Application Valuation: $15,000.00 0�
Applicant: D®�L—®� \� Contractor:
MICHAEL ROBERTS LOREN INDUSTRIES DBA LOREN ELECTRIC SIGN
JUL 1 2018 12226 COAST DRIVE
WHITTIER, CA 90601
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT (562)946-7545
Llc. No.: 455415
1
-----------------------------------------------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: 5 B License No.: 455415
drl i cow, Pw /1.
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
.city or county that requires a permit to construct, alter, improve, demolish, or repair
any.structure, prior to its issuance, also requires the applicant for the.permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant,for a li
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not,
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.):
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the. Contractors' State License Law.).
I I I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the w for which this permit is issued. '
have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: REPUBLIC INDEMNITY COMPANY OF AMERICA Policy Number:
25169401
I certify that in the performance of the work for which this.permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of4he Labor de, I shall forthwith
comply with thgse'prpvisions. / / J n l
� 7 ll S llS Art
WARNING: FAILURE'TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or.pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend,.indemnify and.hold harmless the City of:La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit. '
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
CONSTRUCTION LENDING AGENCY I certify that I have read this application and state that the above information is co rect.
o
I hereby affirm under penalty of perjury that there is a construction lending'agency for I agree to comply with all city and county ordinances and state laws relating to b Iding
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). construction, and hereby authorize representatives of this city o enter upon the
above-m , ntio ed roperty for inspection purposes.
Lender's Name:
�$ 711�[ [i - Sign p p I i c a n t or Agent):
Lender's Address:
Date: 7/18/2018
Application Number:
BSIG2018-0021
Owner:
Property Address:
79174 HIGHWAY 111 101
MAUREEN SHARPE
APN:
600390029
3025 HIGHLAND PARKWAY #350
Application Description:
CHIPOTLE / REPLACE EXISTING SIGNS ,•
DOWNERS GROVE, IL 60515
Property Zoning:
Application Valuation;
$15;000.00
Applicant:
Contractor:
MICHAEL ROBERTS
LOREN INDUSTRIES DBA LOREN ELECTRIC SIGN '
12226 COAST DRIVE
WHITTIER, CA 90601
(562)946-7545
Llc. No.: 455415
Detail:
f
FINANCIAL •R•
':DESCRIPTION ACCOUNT CITY AMOUNT
BSAS SB1473 FEE
101-0000-20306 0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20
101-0000-42403
0
$26.01
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DEVICES, FIRST 20 PC
101-0000-42600
0.
$26.01
Total Paid for ELECTRICAL: $52.02
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $10. 0
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WALL/AWNING SIGN, EA ADDITIONAL
101-0000-42404
0
$26.53
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WALL/AWNING SIGN, EA ADDITIONAL PC
101-0000-42600
0
$26.53
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WALL/AWNING SIGN, FIRST
101-0000-42404
0
$26.53
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WALL/AWNING SIGN, FIRST PC
101-0000742600
0
$93.62
Total Paid for SIGN: $173.21
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00,
Total Paid for TECHNOLOGY ENHANCEMENTTEE: $5.00
' 6
_ ,.; w
PERMIT #
PLAN LOCATION:
Project Address: 7?/7y �(,�Y fit 10
Project - Description:* Pool, Remodel, Add't, Elect, Plumb, Mech
Applicant Name: A
Address:
City, ST, Zip:
Telephone: W -26t — 1c 3 7 7L'^
Email:
Valuation of Project $ /, , oy (7
Contractor Name:zcew
I 'tectVyL
New SFD Construction:
Address: �2� C�.�
�Pt��
v
Conditioned Space SF
City, St, Zip�at i
Garage SF
Telephone: S�z ••G
T.
Patio/Porch SF
Email:
Fire Sprinklers SF
State Lic:. 4/ f ��s` City Bus Lic: G y,Q
Arch/Eng Name:. X/,�
Construction Type: Occupancy:
Address:
Grading:
City, St, Zip
Telephone:
Bedrooms:
Stories:
# Units: ;
Email:
State Lic: City Bus Lic:
-Property Owner's Name:
New Commercial/ Tenant Improvements:
Address: 30
Total Building SF
City, ST, Zip Np���
Construction Type: Occupancy:
Telephone:
Email:
78495 CALLE TAMPICO
LA QUINTA;'CA 92253
ti 760-777-7000
7 - 7
July 3, 2018�
Dennis Stout k
504 E. Palmyva Avenue
Orange, CA 92866
SUBJECT: SIGN PERMIT APPLICATION 2018-0037: CVS Pharmacy
Dear Mr. Stout:
The Design and Development Department has reviewed your request for two (2) new
wall mounted illuminated signs for Chipotle located at 79-174 Highway 111, Unit 101,
within the Pavilions Sign Program. The signs are approved per the sign exhibit on file
and attached, and subject to the following Conditions of Approval:
1. This sign permit grants two (2) new wall mounted illuminated signs to be
designed and located per the approved plan on file (attached).
2. The applicant is required to obtain a building permit prior to installation.
. f
Should you have. any questions or need additional information please feel free to
contact me at (760) 777-7069.
Sincerely,
Carlos Flores
Associate Planner
78-495 Calle Tampico La Quinta, CA 92253 760.777.7000
Must lnven.�
Properties
May 24.i,2018
RE: - 446H /Pavillions at La. Quinta. La. Qu - i n ta,f CA
CHYROTLE"
Dear Tenant:
The signage -drawings for the above referenced'. space prepared by Loren Industries and dated 5/24/18
have been reviewed anal ,approved as noted.
6 All, electrical connections shall be below the roof deck,
Through bolting is only alloweA as.a. last resort method and -Only With Landlord's express Written
In no even ' t shall "the roof or the -parapet, wall of the 'building be penetrated. Any damage to the: roof
or any other compOnent.of tl�!5 buil:dihg.sh.all be: the Tenant's resp6 "bi r t.
onsi i i y o coi 9c
Any penetrations through exterior fagade must have water tight :seal (provide' detail).
Method of attachment must be secure to structure to. support sign (provide. detail).
This .approval is subject to Tenant's compli'ance 'with ...the .lease. Landlord's approval .is in no way a
representation
presentation that, the drawings conform with ;applicable llaws,,.builcling codes- or standards of design,
such. being Tenant's res pons i. bill ity.,
Tenahf!s signage vendors and Contractors are alloweO on the Premises provided that the .Tenants. lease is
fully 'executed and the following requiremen_ts� have, been subm , I - tted to
,maureen,sharpec InvenTrUstpmxom
• Certificate:of,ins.vraftce from all vendors and contractors'
• Copy of sign permit;
Upon completion of installation, photos, must be submitted. include the :$to*reifeOht ,and 'the connection.
a I
Landlord has final right `tb:accept the finished work.
Should you have any questioRs, please contact, me Using my. informati.on, 401.0m.
Sincerely,
Maureen E.. Sharpe
Tenant Coordination Manager
Direc ' t phone: Q.57Q.,0737
Email: 'in aureen,,sha'rpe@lnvenTrus�fOM.to* m
lovenTrust Property Management, LLC
3025.Hj9h16ri! Parkw6y
Suite.156'
Downers Grove; IL 60515
(630) 5704700
lriven'.ty.ListPicfl�L,rti!es,coir, I
1' +
STATE OF CALIFORNIA r
SIGN LIGHTING
:EC-NRCC-L'rS-ot-E(Revised 08/16)" _ CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE "�` NRCC-LTS-01-E
Sign Lighting (Page 1 of 5)
Project Name: /e l Date Prepared: i y !S
A. General Information
Project Address:
Location of Sign
0 oor�SiiGgns ❑ Indoor Signs
Phase of Sign Construction
ew Signs ❑ Sign Alterations
Type of Lighting Control
❑ New Lighting Controls ❑ Replaced Lighting Controls of Installing Lighting Controls
This Certificate of Compliance includes
the following components (check all that apply):
❑ Mandatory Measures (Lighting Controls) ❑ Maximum Allowed Lighting Power Cli pecific Lighting Sources
1. Mandatory Sign Lighting Controls
NOTES:
1. The some responsible person may install both the sign lighting power and the sign lighting controls, or a different responsible
person may install the sign lighting controls than the responsible person installing the sign lighting power.
2. The Mandatory Measures (sign lighting controls) are required for compliance with the sign lighting Standards. If the person
responsible for installing the sign lighting power is not also responsible for the sign lighting controls, then the owner of the sign,
general contractor, or architect shall be responsible to have the sign lighting controls installed.
3. If more than one person has responsibility for compliance, each responsible person shall prepare and sign a Certificate of
Compliance and an Installation Certificate applicable to the portion of construction for which they are responsible; alternatively,
the person with chief responsibility for construction shall prepare and sign the Certificate of Compliance Declaration Statement
for the entire construction (e.g. a C-10 contractor may complete parts la and 1b on one compliance document and a C-45
contractor may complete parts 20 and 2b on a separate compliance document — the Responsible Designer shall submit the two
compliance documents together for the some complete•installotio
I have responsibility for installing the sign lighting controls:
❑ Yes, I have responsibility for the sign lighting controls, and will No, I do not have responsibility for installing the sign lighting controls.
complete parts la and lb of this compliance document Someone else will complete parts la and 1b of this compliance document.
la. Check Y or No for all of the following statements:
The are existing sign lighting controls that comply with the applicable provisions of §110.9 and §130.3
l
Yes ❑ No
_
There are no existing sign lighting controls and I will be installing sn lighting controls that comply with the applicable
2
provisions of §110.9 and §130.3
❑ Yes No
There are existing sign lighting controls that do not comply with the applicable provisions of §110.9 and §130.3 and I will be
3
installing sign lighting controls that comply with the applicabl provisions of §110.9 and §130.3
ElYes [9 No
4
CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance
August 2016
�r •
STATE OF CALIFORNIA
SIGN LIGHTING
CEC-NRCC-LTS-01-E(Revised 08/16) ' CALIFORNIA ENERGY COMMISSION '"w'
CERTIFICATE OF COMPLIANCE NRCC-LTS-01-E
Sign Lighting (Page 2 of 5)
Project Name: Date Prepared:
1b. Mandatory Sign Lighting Controls
If the person signing the Certificate of Compliance Declaration Statement on this NRCC-LTS-01-E is responsible for complying with
the sign lighting control requirements, that person shall answer all of the following questions:
If there are construction documents, indicate where on the building plans'the
mandatory measures (sign lighting control) note block can be located:
1
§130.3(a)1. All indoor sign lighting is controlled with an automatic time -switch control or astronomical time-
Y
N
NA
switch control.
O
O
§130.3(a)2A. All outdoor sign lighting is controlled with a photocontrol in addition to an automatic time-
Y
N
NA
switch control, or an astronomical time -switch control.
2
EXCEPTION to Section 130.3(a)2A: Outdoor signs in tunnels; and signs in large permanently covered outdoor
Y
NA
areas that are intended to be continuously lit, 24 hours per day and 365 days per year.
§130.3(a)2B. All outdoor sign lighting that is ON both day and night is controlled with a dimmer that provides
the ability to automatically reduce sign lighting power by a minimum of 65% during nighttime hours. Signs that
Y
N
NA
3
are illuminated at night and for more than 1 hour during daylight hours shall be considered ON both day and
p
p
night. r
EXCEPTION to Section 130.3(a)2B: Outdoor signs in tunnels and large covered areas that are intended to be
Y
NA
illuminated both day and night.. ' '
0
§130.3(a)3. Demand Responsive'Electronic Message Center Control. An Electronic Message Center (EMC)
'having a new connected lighting power load greater than 1S kW has a control installed that is capable of
Y
N
N/A
4
reducing the lighting power by a minimum of 30% when receiving a demand response signal.
0
�
EXCEPTION to Section 130.3(a)3: Lighting for EMCs that is not permitted by a health or life safety statute,
Y
NA
ordinance, or regulation to be reduced by 30%.
Field Inspector Notes:
F
CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance
August 2016
STATE OF CALIFORNIA
SIGN LIGHTING
'EC
-NRCC-LTS-01-E(Revised 08116) CALIFORNIA ENERGY COMMISSION''
CERTIFICATE OF COMPLIANCE NRCC-LTS-01-E
Sign Lighting (Page 3 of S)
Date Prepared:
Project Name:
Elite Cabinetry 7/3/18
2. Mandatory Sign Lighting Measures
I have responsibility for installing the sign lighting
❑ Yes, I have responsibility for the sign lighting, and will complete ❑ No, I do not have responsibility for installing the sign lighting. Someone
parts 2a and 2b of this compliance document else will complete parts 2a and 2b of this compliance document.
2a. Maximum Allowed Lighting Power Method of Compliance
Certificate of Compliance and Field Inspection Energy Checklist.
Complete this part if there are signs using the maximum allowed lighting power method of compliance. (Complete part 2b of this
Certificate of Compliance if there are signs using the Specific Lighting Sources method of compliance):
A
B
C
D E F G
H
1
J
OPTIONAL —
Symbol or
y
Description of the Sign
Energy Verified
Label (see
Allotted Watts
Design
Complies
Field
Inspector
Code
instructions
Watts
Y/N
Check that
below)
Sign Complies
"
y^
p -
N Nam..
N
�+
Gl tw
A
�l
—
X
Q
c E
3� N'a
CD
v
c N
te
T
59
in
Cl X p
UJ
II I I
Q-w
p
Q
a+
�3
a
0
U
✓
✓
N1
LED
❑
45.8
1
12
549.6
120
Yes
I ❑
N2
LED
❑
45.8
1
12
549.6
120
Yes
❑
❑
0
❑
❑
0
❑
❑
0
❑
❑
0
❑
❑
0
❑
❑
0
❑
❑
0
❑
❑
0
❑
A
Symbol or code used on the plans (when plans are required) and other documents.
B
A description.of the sign, or location of sign on the building; and the location of sign on construction documents.
OPTIONAL - Check this box only if this sign has a permanent, pre-printed, factory -installed, ENERGY VERIFIED label, confirming that
the sign complies with the Section 140.8 of the California 2016 Title 24, Part 6 Standards, using the Maximum Allowed Lighting
Power.method of compliance. The only labels that will be recognized for this purpose are ENERGY VERIFIED Certification Marks:
C
authorized by Underwriters Laboratories (UL) or other Product Certification Body accredited to ISO/IEC Guide 65 by the American
National Standards Institute in accordance with ISO/IEC 17011. Surveillance by the Accredited Certification Body shall be an
ongoing annual inspection program carried out by aType A Inspection body in accordance with ISO/IEC 17020. For signs with such
an ENERGY VERIFIED label, columns 'D' through '1' are not required to be filled out. Note: Using an ENERGY VERIFIED label is an
optional method to validate compliance. An ENERGY VERIFIED label is not needed for compliance.
D
The sign area in square feet.
E
List "I" if the sign is internally illuminated. List "E" if the sign is externally illuminated.
F
Allowed watts per square foot. Enter 12 if the sign is listed as "I" in column E. Enter 2.3 if sign is listed as "E" in column E.
G
Multiply'the square footage in column D times the allowed Lighting Power Density. (LPD = watts) in column F.
H
Show the total installed watts in the sign, as determined according to the applicable provisions of §130(c).
I_
Enter Y if the number in column H is less than or equal to the number in column G. Otherwise, the sign does not comply.
J
This page doubles as a field inspection checklist.
Field Inspector Notes:
CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance August 2016
a�
2; STAVE OF CALIFORNIA
'SIGN LIGHTING
Ral
CEC-NRCC-LTS-01-E(Revised 08/16) CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-LTS-01-E
Sign Lighting (Page 4 of 5)
Project Name: Date Prepared:
,Q` rS /� des
2b. Specific Lighting Source Method of Compliance
Certificate of Compliance and Field Inspection Energy Checklist
Complete this part if there are signs using the Specific Lighting Source method of compliance. (Complete part 2 of this Certificate of
Compliance if there are signs using the maximum allowed lighting power method of compliance)
A
B
C
D
E
OPTIONAL
ENERGY
Specific light source used for
Symbol
VERIFIED
compliance
Field Inspector
or
Description
label
Shall include only lighting
Check that Sign
Code
(see
technologies listed below
Complies
instructions
(List all that apply)
below)
All
/ vmj
❑
❑
Nt
WAY V"W
❑
7
❑
❑
O
❑
❑
A
Symbol or code used on the plans (when plans are required) and other documents.
B
A narrative description of the sign, or location of sign on the building; and the location of sign on construction documents
OPTIONAL - Check this box only if this sign has a permanent, pre-printed, factory -installed ENERGY VERIFIED label, confirming that this sign
complies with the Section 140.8 of the California 2016 Title 24, Part 6 Standards, using the Specific Lighting Source Method of Compliance.
The only labels that will be recognized for this purpose are ENERGY VERIFIED Certification Marks authorized by Underwriters Laboratories
C
(UL) or other Product Certification Body accredited to ISO/IEC Guide 65 by the American National Standards Institute in accordance with
ISO/IEC 17011. Surveillance by the Accredited Certification Body shall be an ongoing annual inspection program carried out by a Type A
Inspection body in accordance with ISO/IEC 17020. For signs with such an ENERGY VERIFIED label, column 'D' is not required to be filled
out. Note: Using an ENERGY VERIFIED label is an optional method to validate compliance. An ENERGY VERIFIED label is not needed for
compliance.
Specific Light Source Compliance Method. The sign(s) identified above use only the following lighting technologies:
List all applicable numbers (1 through 9) that apply in column D above for each row.
1
High pressure sodium lamps
Metal halide lamps that are pulse start or ceramic served by a ballast that has a minimum efficiency of 88% or greater.
2
Ballast efficiency is the measured output wattage to the lamp divided by the measured operating input wattage when
tested according to ANSI C82.6-2005.
Metal halide lamps that are pulse start that are 320 watts or smaller, are not 250 watt or 17S watt lamps, and are
3
served by a ballast that has a minimum efficiency of 80%.
Ballast efficiency is the measured output wattage to the lamp divided by the measured operating input wattage when
tested according to ANSI C82.6-2005.
Neon or cold cathode lamps with transformer or power supply efficiency greater than or equal to a minimum efficiency of 75% when
D
4
the transformer or power supply rated output current is less than 50 mA. The ratio of the output wattage to the input wattage is at
100%tubing load.
Neon or cold cathode lamps with transformer or power supply efficiency greater than or equal to a minimum efficiency of 68% when
5
the transformer or power supply rated output current is 50 mA or greater. The ratio of the output wattage to the input wattage is at
100% tubing load.
6
Fluorescent lighting systems meeting one of the following requirements: A.) Use only lamps with a minimum color rendering index
(CRI) of 80; or B.) Use only electronic ballasts with a fundamental output frequency not less than 20 kHz.
7
Light emitting diodes (LEDs) with a power supply having an efficiency of 80% or greater.
Single voltage external power supplies that are designed to convert 120 volt AC input into lower voltage DC or AC output, and have a
8
nameplate output power less than or equal to 250 watts, shall comply with the applicable requirements of the Appliance Efficiency
Regulations (Title 20).
9
Compact fluorescent lamps that do not contain a medium screw base sockets (E24/E26).
E I
This page doubles as a field inspection checklist.
Field Inspector Notes:
CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance August 2016
STARE OF CALIFORNIA
',SIGN LIGHTING
GEC-NRCC-LTS-01-E(Revised 08/16) CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-LTS-01-E
Sign Lighting (Page 5 of 5)
Project Name: Date Prepared:
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: /fA��l�
/
Documentation Author Signature:
/�
Company: - //-
G.Q/1QA�
Signature Date:
Address:
laa� G Co ,04 C"
CF.A Certification Identification (if applicable): -
City/State/Zip:
Phone:
7
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified
on this Certificate of Compliance (responsible designer).
3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system
design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information
provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement
agency for approval with this building permit application.
5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building perm' s) issued for the
building, and made available to the enforcement agency for all applicable inspections. I understand that a completed sited copy of this
Certificate of Compliance is required to be included with the documentation the builder provides to th Iding caneoccupancy.
Responsible Designer Name: %J/f
/Y! ry/
Responsible Designer Signature:
Company:
Date Signed:
Address: -
�DO1�
License:
• o
/j
City/State/Zip: 7 e4 0 t4 /•
Phone: '
Y
t_
r
CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance
`, August 2016
S C H E D U L E
N1 - SIGN TYPE BW-3: LED ILLUMINATED FLAT PEPPER LOGO Et CHANNEL LETTERS WITH HALO
N2 - SIGN TYPE BW-3: LED ILLUMINATED FLAT PEPPER LOGO Et CHANNEL LETTERS WITH HALO
N3 - STORE DOOR VINYL GRAPHICS
CITY OF LA UINTA
E3UILDING & SAFETY DEPT:
APPROVED
FOR CONSTRUCTION
noTt= L1�BY
R
A P P R O V A L
?ate
v
Q Q Q Q ;
DSW Desgner
`,,hoe W 1re11UUSf-
Q SITE
O #79174 California 111
ra -_
Q
T�e 11PS �'�orr -
OMa,snars
O°:�'- velSrnarl
CHIPOTLE #1094
79-174 Highway 111 Unit 101
La Quinta, CA 92253
S I G N C 0 D E
ALLOWABLE SQ. FT. 000 PROPOSED SQ. FT. 000
L E G E N D
NEW EXISTING SIGN EXISTING SIGN EXISTING SIGN
N1 PROPOSED R1 TO BE REPLACED X1 TO BE REMOVED --[E
1 TO REMAIN
fir J6
14
�y A
i
VICINITY MAP NOT TO SCALE AERIAL PHOTO / SITE PLAN
FA
LDR=N
LOREN INDUSTRIES
12226 Coast Drive
Whittier, CA 90601
Tel: (562) 946 7545
Fax: (562) 949-5707
St. Lic.: 455415
Las Angeles, CA
D RAW I fv.'. ..
03-18-0001 R1
1 7
CHIPOTLE
r
ADDRESS
79-174 Highway 111 Unit 101
La Quinta, CA 92253
Approval Signature
DATE:
03/19/2018
PROJECT MANAGER
Carla T.
DESIGNER:
EC
REVISION DATE:
d05-10-2018
tti-
! REVISION BY:
IF
Gilbert S. V
e�
1 ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY LOREN
ELECTRIC SIGN CORPORATION AND
SHALL NO BE REPRODUCED. USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
u""�►w. --.--�'''i;i;i:,,y4 PURPOSE WHATSOEVER WITHOUT
PERMISSION OF LOREN ELECTRIC
NOT TO SCALE SIGN CORPORATION.
SITE PLAN
11
0
Now lolp-mmw
f
_ ille'
one Ilk
Scale: N.T.S.
FA
LOREN
LOREN INDUSTRIES
12226 Coast Drive
Whittier, CA 90601
Tel: (562) 946-7545
Fax: (562) 949-5707
St. Lic.: 455415
Los Angeles, CA
03-18-0001 R1
2 r 7
CHIPOTLE
ADDRESS
79-174 Highway 111 Unit 101
La Quinta, CA 92253
Approval Signature
DATE:
03/19/2018
PROJECT_ MANAGER
Carla I
DESIGNER:
EC
REVISION DATE:
05-10-2018
REVISION BY:
Gilbert S.
ALL IDEAS, PLANS, AIID ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY LOREN
ELECTRIC SIGN CORPORATION AND
SHALL NOT BE REPRODUCED, USED
BY OR UISLLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF LOREN ELECTRIC
SIGN CORPORATION.
A ij 79-1 a 4
a,
NOTE:
CHANNEL LETTER SIGN TO BE INSTALLED
VERTICALLY CENTERED FROM OLD SIGN
Ft BOTTOM OF SIGN ALIGNS WITH ROOF EDGE AS SHOWN.
EXISTING
PROPOSED
F-1
NORTH ELEVATION (STOREFRONT)
NIGHT VIEW
Scale- NTS
FA
LOREN
LOREN INDUSTRIES
12226 Coast Drive
Whittier, CA 90601
Tel: (562 ) 946-7545
Fax: (562 ) 949-5707
St. Lic-: 455415
Los Angeles, CA
oaa.wr+cawlsloN NO
03-18-0001 R1
3 (IF 7
CLIENT:
CHIPOTLE
ADDRESS
79-174 Highway 111 Unit 101
La Quinta, CA 92253
Approvat Signature
DATE:
03/19/2018
PROJECT MANAGER
Carla T.
DESIGNER:
EC
REVISION DATE:
05-10-2018
REVISION BY:
Gilbert S.
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY LOREN
ELECTRIC SIGN CORPORATION AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF LOREN ELECTRIC
SIGN CORPORATION.
NIGHT VIEW
EXISTING
,F
n SOUTH ELEVATION (BACK)
l-�
Scale- NTS
FA
LOREN
LOREN INDUSTRIES
'ill ih I.n1,r unvr
Whittier, CA 90601
Tel: (562) 946-7545
Fax: (562) 949-5707
St. Lic.: 455415
Los Angeles, CA
DRAWING/REVISION NO.:
03-18-0001 R1
'AGE �c
4 2( 7
CLI[NT:
CHIPOTLE
ADDRESS
79-174 Highway 111 Unit 101
La Quinta, CA 92253
Approval Signatwe
DATE:
03/19/2018
PROJECT MANAGER
Carla T.
DESIGNER:
EC
REVISION DATE:
05-10-2018
REVISION BY:
Gilbert S.
ALL IDEAS. PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY LOREN
ELECTRIC SIGN CORPORATION AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF LOREN FI FrTRir
SIGN CORPORATION.
5'-Y18
2'- 6'/2'
N1 IN2 SIGN TYPE BW-3: LED ILLUMINATED FLAT PEPPER LOGO Et CHANNEL LETTERS WITH HALO
TOTAL SQ. FT.: 45.8
SPECIFICATIONS:
FACE LIT CHANNEL LETTERS
FACES: ............... .177" CYRO #2447 MILK -WHITE ACRYLIC W/ "ADOBO BROWN" VINYL
RETURNS:......... .040" X 3" PRE -FINISHED PTM PMS #4625-C "ADOBO BROWN"
BACKS: .............. '/8" ACM
TRIM CAP:.......... 1" JEWELITE TRIMCAP BROWN
ILLUMINATION:.. WHITE LED'S
PEPPER LOGO & LETTERS WIREWAY.
FACES-. .............. .090" ALUMINUM PTM PMS #484-C "ROASTED RED & PMS #4625-C
"ADOBO BROWN"
RETURNS:......... 2" ALUMINUM ANGLE & .063" FORMED RADIUS CORNERS
PTM PMS #484-C "ROASTED RED & PMS #4625-C "ADOBO BROWN"
BACKS: .............. .090" ALUM.,NOTCHED BACKS W/ .177" WHITE ACRYLIC STRIPS
AND VHB TAPE TO 1"ALUM SQ TUBE FRAME
STAND-OFFS:.... 3/al' ALUM ROUND TUBE, 1 '/2" LONG PAINTED WHITE
BACKER PANEL:
FACE: .................
FRAME: .............
.090" ALUMINUM PAINTED WHITE
1'/2" X 1'/2" ALUM RECT TUBE & .063" FORMED RADIUS CORNERS
PAINTED WHITE
2' -
COLOR SPECIFICATIONS:
Roasted Red"
PAINT: PMS #484-C FINISH
Adobo Brown"
PAINT: PMS #4625-C FINISH
177" CYRO #2447 MILK WHITE ACRYLIC FACES
PAINT: WHITE
GENERAL NOTES:
CHP-CL-BG-BW3
1.) INSTALLATION OF THIS SIGN SHALL CONFORM
TO THE REQUIREMENTS OF ARTICLE 600 OF NEC, UL48 AND/OR
OTHER APPLICABLE LOCAL CODES.
2.) BRANCH CIRCUIT:
A.) ALL BRANCH CIRCUITS FOR SIGNS MUST BE TOTALLY
DEDICATED TO SIGNS (INCLUDING DEDICATED
GROUND AND DEDICATED NEUTRAL PER CIRCUIT).
B.) SIGN CIRCUITS MUST NOT BE SHARED WITH OTHER LOADS
SUCH AS LIGHTING, AIR CONDITIONING
AND OTHER EQUIPMENT.
C.) PROPERTY SIZED GROUND WIRE THAT CAN BE TRACKED
TO THE BREAKER PANEL MUST BE PROVIDED.
3.) U.L. AND DATA LABELS REQUIRED
4.) SIGN SATISFIES ALL REQUIREMENTS OF TITLE 24.
5.) OUTDOOR SIGNAGE TO EMPLOY EITHER PHOTOCELL
OR OUTDOOR ASTRONOMICAL TIMER.
Scale: 1/4" = 1'-0"
1 1/2 "
1/2 "
2"
3"
SIDE VIEW
Scale: 1 " = 1 ' -0"
FA
LOREN
LOREN INDUSTRIES
12226 Coast Drive
Whittier, CA 90601
Tel: (562) 946-7545
Fax: (562) 949-5707
St. Lic.: 455415
Los Angeles, CA
Cr�`P O T<cn
3 � �
F
+MCA N C'
DRAWING- REVISICN '.C.
03-18-0001 R1
1a G l
5 7
CHIPOTLE
ADDRESS
79-174 Highway 111 Unit 101
La Quinta, CA 92253
Approval Signature
x
DATE:
03/19/2018
PROJECT MANAGER
Carla I
DESIGNER:
EC
REVISION _ DATE.
05-10-2018
REVISION BY:
Gilbert S.
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY LOREN
ELECTRIC SIGN CORPORATION AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF LOREN ELECTRIC
SIGN CORPORATION.
11/2"
3/4" X 3/" X .090" ALUM, ANGLE
W/ POP -RIVET TO ALUM. BACK
.063" ALUM. RETURN WELDED TO
ALUM. CABINET FACE
11/2"
2"
I
.090" ALUM. CABINET FACE
#10 TEK SCREWS
3"
1 " BROWN JEWELITE TRIM CAP
—t
3/16" CYRO #2447 MILK WHITE ACRYLIC \
I'
ALUMINUM OVERLAY (PEPPER LOGO ONLY)
BACKS: /8" ACM (LETTERS)
A
WHITE L.E.D.
li
PRIMARY ELECTRICAL
POWER SUPPLY W/ TOGGLE SWITCH
WHITE LED'S W/ .040"
BREAK -FORMED ALUMINUM BAFFLE.
r u
090" ALUM, NOTCHED BACKS W/ .177"
WHITE ACRYLIC STRIPS AND VHB TAPE
WEEP HOLES
FASTENERS AS REQUIRED
(PER WALL CONDITION)
3/8"X3" SCREWS INTO WOOD FRAMING
(8 SCREWS MINIMUM)
EXISTING WALLS ARE STUCCO
WITH WOOD FRAMING.
INSTALLATION SPECIFICATIONS:
ALL HARDWARE SHOULD BE CORROSION RESISTANT.
RECOMMENDED MOUNTING HARDWARE:
1/2"x8" THREADED RODS W/NUTSPLIT WASHER Et FLAT
WASHERS THROUGH BOLTED TO 2"x2"x3/16" ALUMINUM
ANGLE SPANNING A MINIMAL OF TWO STUDS.
GENERAL NOTES, -
ELECTRICAL COMPONENTS TO BE UL LISTED
AND INSTALLED IN ACCORDANCE WITH THE
NATIONAL ELECTRIC CODE (NEC)
ALL WIRING SHALL BE 12 GA
(1) 20 AMP-120V CIRCUIT TO BE BROUGHT
TO JOB SITE BY LICENCED ELECTRICIAN.
ALL SIGNAGE WILL BE UL2161 COMPLIANT
AND CARRY UL LABELS.
SECTION DETAIL: LED ILLUMINATED FLAT PEPPER LOGO Et CHANNEL LETTERS WITH HALO
@LISTED
THIS SIGN IS INTENDED TO BE
INSTALLED IN ACCORDANCE
WITH THE REQUIREMENTS OF
ARTICLE 600 OF THE NATIONAL
ELECTRICAL CODE Et ALL OTHER
APPLICABLE LOCAL CODES.
THIS INCLUDES PROPER
GROUNDING AND BONDING OF
THE SIGN.
COLOR SPECIFICATIONS:
■ P.T.M. PMS 484 C "Roasted Red"
■ P.T.M. PMS 4625 C "Adobo Brown"
"PEPPER" LOGO FACE 3/16" CYRO #2447 MILK WHITE ACRYLIC
WITH ALUMINUM OVERLAY
3/16" CYRO #2447 MILK WHITE ACRYLIC
Scale: NTS
FA
LOREN
LOREN INDUSTRIES
12226 Coast Drive
Whittier, CA 90601
Tel: (562) 946-7545
Fax: (562) 949-5707
St. Lic.: 455415
Los Angeles, CA
t/Cc�"
A N C'
03-18-0001 R1
6 7
CHIPOTLE
ADDRESS
79-174 Highway 111 Unit 101
La Quinta, CA 92253
Approval Signature
DATE:
03/19/2018
PROJECT MANAGER
Carla T.
DESIGNER:
EC
REVISION DATE:
05-10-2018
REVISION BY:
Gilbert S.
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY LOREN
ELECTRIC SIGN CORPORATION AND
SHALL NOT BE REPRODUCED. USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF LOREN ELECTRIC
SIGN CORPORATION.
12"
F3M WHITE VINYL STORE DOOR LOGO
3
QTY. (4)
Manufacture and install vinyl first
surface white opaque door vinyl.
Center of "LOGO GRAPHIC" to be
4'-2" above finished floor (AFF).
3M BLOCKOUT FILM WHITE MATTE
(3635-20B)
SCALE: 3"=1 ' -O"
14"
AV I
co OIE:]]
OAM
0
v
M
NDA
QTY. (1)
3M WHITE VINYL STORE SERVICE HOURS
V-1 1 /2"
'Single Door Application
•
SERVI ;F= DOOR
00
T
r.
Manufacture and install vinyl first
surface white opaque door vinyl. o
QTY. (1 1 Center line of text to be T-4" above finished floor (AFF).
I n n:oo .l¢ao
3M BLOCKOUT FILM WHITE MATTE
(3635-20B) o 00
3M WHITE VINYL STORE SERVICE DOOR LETTERS
N3 A,,.
DOOR VINYL GRAPHICS
*Double Door Application
Manufacture and install vinyl first
surface white opaque door vinyl.
Center line of text to be 2'-0" above finished floor (AFF).
3M BLOCKOUT FILM WHITE MATTE
(3635-20B)
--T T"",
T
SCALE: 1 "=2"
"Service Door Application
t
--� seRvlc,� Dooa
STANDARD APPLICATION REQUIREMENTS (ACTUAL HOURS AND GRAPHICS WILL VARY BY STORE)
SCALE: 1 "=2" F-1SCALE: 3/8"=1'-O"
SCALE: AS NOTED
FA
LOR=N
LOREN INDUSTRICS
12226 Coast Drive
Whittier, CA 90601
Tel: (562) 946-7545
Fax: (562) 949-5707
St. Lic.: 455415
Los Angeles, CA
DRAWING: REV1610N 1,1`
03-18-0001 R1
PAGE : U _
7 OF 7
CLIENT:
CHIPOTLE
ADDRESS
79-174 Highway 111 Unit 101
La Quinta, CA 92253
Approval Signature
DATE:
03/19/2018
PROJECT_ MANAGER
Carla T.
DESIGNER:
EC
REVISION DATE:
05-10-2018
REVISION BY:
Gilbert S.
ALL IDEAS. PLANS. AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY LOREN
ELECTRIC SIGN CORPORATION AND
SHALL NOT BE REPRODUCED. USED
BY OR DISCLOSED TO ANY PERSONS,
h IRM UK LUKKU KAI IUN FUK ANY
PURPOSE WHATSOEVER WITHOUT
PFRMISSION OF I nRFN FI FCTR.IC
SIGN CORPORATION.