BPOL2019-0104cz? -
78-495 CALLE TAMPICO D V Qa4a VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 5/17/2019
Permit Type/Subtype:
POOL/PRIVATE
Owner:
Application Number:
BPOL2019-0104
LENNAR HOMES
Property Address:
54465 SEA HERO CIRs-
APN:
767780032
CA 0
Application Description:
LENNAR / POOL, SPA, [2) GAS OUTLETS
Property Zoning:
®
cn
Application Valuation:
$25,000.00
cOv
e~
Applicant:
Contractor:
�-
Q
TESERRA
TESERRA
>--
P O BOX 1280
P O BOX 1280
COACHELLA, CA 92236
COACHELLA, CA 9
q
(760)389-9222
Llc. No.: 656128
W
Q
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 70001 of Division 3 of the Business and Professions Code,
and my License is in full Force and effect.
License Class: CJ8 1 3 7 Lice se No.: 656128
Date: Contrac
OWNER -BUILDER DECLA N
I hereby affirm under penalty of perjury that I am empt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
() I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.),
() I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Addres
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of o for which this permit is issued.
ave and will maintain workers' compensation insurance, as required by
action 3700 of the Labor Code, for the performance of the work for which this permit
is issued, My workers' compensation insurance carrier and policy number are:
Carrier: BENCHMARK_I_N_ $QRANCE_COMPANY Policy Number: CST5014959
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with Lhasa pr isians.
Dot Applicant:
WARNi : FAILU E TO SECURE WORKERS' COMPEN N COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL P ALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). N ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above -mentioned operty for inspection purposes.
Date: Signature (Applicant or
Date: 5/17/2019
Application Number:
Property Address:
APN:
Application Description
Property Zoning:
Application Valuation:
Applicant:
TESERRA
P 0 BOX 1280
COACHELLA, CA 92236
BPOL2019-0104
54465 SEA HERO CIR
767780032
LENNAR / POOL, SPA, [2] GAS OUTLETS
$25,000.00
Owner:
LENNAR HOMES
,CA0
Contractor:
TESERRA
P 0 BOX 1280
COACHELLA, CA 92236
(760)389-9222
Llc. No.: 656128
Detail: POOL, SPA AND [2] GAS OUTLETS FRONT YARD (DOUGLAS FERRELL ENGINEERING.] NEW EQUIPMENT MUST BE LOCATED IN AN APPROVED
LOCATION EITHER WITHIN THE REAR YARD SETBACK OR 5' MINIMUM FROM THE SIDE P/L--FIELD VERIFY. THIS PERMIT DOES NOT INCLUDE EQUIPMENT
ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. SPECIAL INSPECTION REPORT REQUIRED AT PRE PLASTER.
2016 CALIFORNIA BUILDING CODE
DESCRIPTION ACCOUNT CITY AMOUNT
BSAS SB1473,FEE 101-0000-20306 0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20
101-0000-42403
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20 PC
101-0000-42600
0
$26.68
Total Paid for ELECTRICAL: $53.36
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS PC
101-0000-42600
0
$26.68
Total Paid for PLUMBING FEES: $40.02
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SWIMMING POOL/SPA
101-0000-42404
0
$200.12
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SWIMMING POOL/SPA PC
101-0000-42600
0
$108.87
Total Paid for POOL / SPA: $308.99
DESCRIPTION
ACCOUNT CITY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416 0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
Architect/Engineer Name:
Address:
City, St, Zip
Telephone:
Email:
State Lic: City Bus Lic:
Construction
Grading:
Bedrooms: I Stories:
Occupancy:
# Units:
78495 CALLE TAM PICO r�
LA QUINTA, CA 92253 k � � � �- ��� � ���v' 1
760-777-7000.�^-
OFFICE USE ONLY
I
# Submittal Required Received
Plan Sets
Structural Calcs
Truss Calcs
i Title 24 Calcs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
Permit Type:
Pool
Application Date:
05/10/2019
Parcel
767780032
Work Class:
Pool Construction (Private)
Issue Date:
05/17/2019
Address:
54465 SEA HERO CIR
Duane Clayton
- NO UNDERGROUND WORK COMPLETED
06/06/2019
Duane Clayton
LA QUINTA, CA 92253
Status:
Expired
Expiration Date:
03/04/2020
Description:
LENNAR / POOL, SPA, [2] GAS
JAN: 190716051249
Approved Julio Anaya
No Complete
Electrical
3281
OUTLETS """ POOL, SPA AND [2]
Underground Gas
JAN:190716051249
Approved Julio Anaya
No Complete
GAS OUTLETS FRONT YARD
3282
Underground
JAN:190716051249
[DOUGLAS FERRELL ENGINEERING.
No Complete
Plumbing
3283
NEW EQUIPMENT MUST BE LOCATE
IN AN APPROVED LOCATION EITHEF
WITHIN THE REAR YARD SETBACK
OR 5' MINIMUM FROM THE SIDE P/L-
-FIELD VERIFY. THIS PERMIT DOES
NOT INCLUDE EQUIPMENT
ENCLOSURE. ALARMS AND
BARRIERS REQUIRED TO BE
INSTALLED AT PRE -PLASTER
INSPECTION. SPECIAL INSPECTION
REPORT REQUIRED AT PRE PLASTE
2016 CALIFORNIA BUILDING CODE
Owner:
LENNAR HOMES
Contractor:
TESERRA TESERRA Applicant:
TESERRA TESERRA
Scheduled
Actual
Reinspection
Date
Start Date Inspection Type
Inspection No.
Inspection Status Primary Inspector
Required? Complete
06/05/2019
Pre-Gunite
JAN:190604044352
Approved
Duane Clayton
No Complete
2097
06/06/2019
Footing
JAN:190605045626
Not Ready
Duane Clayton
No Complete
3055
NOTES Created By
Duane Clayton
Duane Clayton
TEXT
Created Date
- NO FOOTING WORK COMPLETED. 06/06/2019
ADDITIONALLY, NO CMU WALLS ARE
INCLUDED IN THE SCOPE OF WORK FOR T
PERMIT.
- INSPECTION REQUEST WAS FOR PERMI' 06/06/2019
BPOL2019-0114.
Underground Gas
JAN:190605045626
Not Ready Duane Clayton
No Complete
3056
NOTES Created By
TEXT
Created Date
Duane Clayton
- NO UNDERGROUND WORK COMPLETED
06/06/2019
Duane Clayton
- INSPECTION REQUEST WAS FOR PERMI'
06/06/2019
BPOL2019-0114.
07/17/2019 Underground
JAN: 190716051249
Approved Julio Anaya
No Complete
Electrical
3281
Underground Gas
JAN:190716051249
Approved Julio Anaya
No Complete
3282
Underground
JAN:190716051249
Approved Julio Anaya
No Complete
Plumbing
3283
October 08, 2024
78-495 Calle Tampico
Page 1 of 2
Permit Type: Pool
Work Class: Pool Construction (Private)
Status: Expired
Application Date: 05/10/2019
Issue Date: 05/17/2019
Expiration Date: 03/04/2020
Parcel
Address
Description
Owner: LENNAR HOMES Contractor: TESERRA TESERRA Applicant:
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
08/19/2019 Deck Bond DCL:190816043731 Disapproved Duane Clayton
1691
09/06/2019
Pre-Plaste
NOTES Created By TEXT
767780032
54465 SEA HERO CIR
LA QUINTA, CA 92253
LENNAR / POOL, SPA, [2] GAS
OUTLETS "" POOL, SPA AND [2]
GAS OUTLETS FRONT YARD
[DOUGLAS FERRELL ENGINEERING.
NEW EQUIPMENT MUST BE LOCATE
IN AN APPROVED LOCATION EITHEF
WITHIN THE REAR YARD SETBACK
OR 5' MINIMUM FROM THE SIDE P/L-
-FIELD VERIFY. THIS PERMIT DOES
NOT INCLUDE EQUIPMENT
ENCLOSURE. ALARMS AND
BARRIERS REQUIRED TO BE
INSTALLED AT PRE -PLASTER
INSPECTION. SPECIAL INSPECTION
REPORT REQUIRED AT PRE PLASTE
2016 CALIFORNIA BUILDING CODE
TESERRA TESERRA
Reinspection
Required? Complete
No Complete
Created Date
Duane Clayton - UNABLE TO VERIFY CONTINUOUS BOND 08/19/2019
WIRE AND FOUR EQUIDISTANT BONDING
POINTS. WORK COVERED PRIOR TO
INSPECTION.
I
r JAN: 190905043203 Approved Duane Clayton No Complete
2652
NOTES Created By TEXT Created Date
Duane Clayton - SPECIAL INSPECTION REPORT FOR 09/06/2019
SHOTCRETE PLACEMENT RECEIVED. SEE
ATTACHMENTS.
October 08, 2024 78-495 Calle Tampico Page 2 of 2
09-06-2019 09:37:26 AM GPS X= 33.653229 Y=-116.250...
1
Jimenez
Special
Inspections
DAILY REPORT OF INSPECTION
Date of Inspection: 6-7-2019
Building Permit No.: BPOL2019-0104
Project Name: Griffin Ranch Lot 255
Protect Address: 54465 Sea Hero Circle, La Quinta, CA
Architect: Structural Engineer: Douglas R. Ferrell
General Contractor : Teserra Builders
79-735 Oxford Dr
Indio Ca. 92203
760-250-0884
Fax 760-772-7701
Sub Contractor: Valley Gunite
Job No.: 340-19
TYPE OF INSPECTION:./ Concrete Masonry ❑ Steel U Epoxy Others Gunite
Welder,Welding Operators & Certification Numbers:
Description of Work Inspected: 24393
1) Observed placement of gunite for in ground pool, Gunite placed per ACI 506
contractor placed 40 c.y. Placement -satisfactory
2) Sample taken from truck 73264M1 at the Southside wall from the spa stand alone waterfall
Rebar inspected by others
Unresolved Items:
1 hereby certify that 1 have inspected all of the above reported work, unless ortherwise noted, and to the best of my ability 1 have, found this work
to comply with the approved plans, specifications do applicable building laws. Final report issued at prplehon
Inspector's Name/No.Isaac Urrutia/01534147
All Inspections based un a minimum of 4 hours:
over 4 hours will be 8 hours minimum
inspector's Signature
Contractor's RepresentativeW.,....-en....--------°.--------..
•NO EXISTING LANDSCAPE LIGHTING IN REAR YARD 9iPECIEIcnnplNs. '"
15TSO.FT. POURED IN PLACE COPING ANO CMS mq
• NO EXISTING OVERHEAD UTILITY LINES IN REAR YARD
PE GUNITE SIZE AM'd" % 14'-G• N P
"PATIO FURNITURE FOR ILLUSTRATION PURPOSES ONLY nu so.Fr. PAVER DECKERS BY orrveas
ERIMEEAREA OF POOL ONLY 4DEPTHS. - IRm
0C.&ER�>BINED . DEPTHS MW_T�'r➢--MAX Qmm
COL&6PA COMBINED 54480 FT. /130 LRFi. CON
PA SPECIFICATIONS TILE 'ICN
SI $' Z-- " _ S¢Fl: �,1`$_LN. FT �88TIlE W..'B
WAl5WN III T.86. >_NQ
SADAM WALL WN RAN QE4.Z
pL -,u OWN DUNm
6• m 8PAAT+TAN'R MN�
5 LLWAYIYP NTT
S ECIM NOTE DECKING wmG
Y /� ••• PECAV&'��I J (STEEL $0 FT. SPE NOTE
MAI LIGHT BROOM poO
CITY OF LA ( UINTA E86iR STREET WITILE bI Oy
BUILDING DIVISION °�` OB£GxTILEE
L e. NO diN 2
C NCPEIE PEMWAL NO LOA GLEEV B
REVIEWED FOR DREMWAL NO L BIEPS
EE roN NEE
E BY ND' S DAN
CODE l¢O NEEMWALBY— TILER E
CA¶ON REPAW — EARGE V190UEEN
COMPLIANCE BB - BPRDB
R 86 MWI TRIP
10 FILL
SPA EO WEDAIREI
T41QGNG NC OPo YE8
,,.,, / N'flBB — WEIDSCUE...
DATE�BY� .RBB - REBAR
i &IELFBE%H 12 WO BARBECUE CCIINIERTOP
C iERB RBB. FACING TILE
SWLLWAYTI9E BTACKEC STONE SIYc 8'G'
LUM SING STEPS
R TER JANDY v&ZEm 5 0 O. FT. PROP. ER WALL — / /\ — p wMPJANDYE Wg 2HP V6P NETPLANN NGWALL— ■ / 1y�
L
— WMP�BI}E. ECUIR WALL.— iI ) P
/ EERCESCENTPUMP.SEE SAT 1y
L_� I
q CATER
� SEE — NPEPR ER P
LENNAR TO SUPPLY MAIN N Tea JANOy RN moas0 eru B. g! V PUN
------�
I I I I I I GAS, ELECTRIC AND WATER mR 114MAPOUBE BANos.r PAVE
c LORI'Mroq PLC1400 MURE sNC AT BPRBECUE
_ _ CONNECTIONS AT POOL ' ELEs6mxma I uralNrc PAIM A Ecu
EQUIPMENT AREA SIMMER WFE Du PORT
1 �- N LINE MPPRODUCTSAUTOFILL
________________
r I YES 5Iu B IFI 1 U RB 3- C U
II _ POOL EQUIPMENT TO BE WATER ER wE — Eap6Eow,I'N"ALL—
F.
BONDED AT THIS LOCATION L GIx a-nu4c1zw1o0 DEEpxEATREN
S IN 6P 1-JLWCSW50 DEEVO ES
POOL EQUIPMENT: 400,000 BTU HEATER a OG I WA. QGM INEm
e B6ELEWIp.EM YES FENCING
'ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED P BIN.. z+rz'sucTlaJaz+rr gETURN psNCEmE
IN HOUSE RS6 -- EPHEATPAG(AG N/A
I II I LOCATION I' POOL EQUIPMENT 50 AMP SUBPANEC Q INFLQCR WA GATE
I I — WITH 36` CLEARANCE AT FRONT AND SIDE. uM GAAI wA
7'-6"X3'HARD TROWELED AND SEALED SMOOTH COLOR L—__— IJ Iv Yes are REYER6PL
CONCRETE COUNTERTOP AT-36", ALFRESCO ALXE-38 1 -'� _--------_--� II' 12'-9" M c gEMovEa REHa,G
I —
36" BARBECUE, OLC3838" STAINLESS STEEL ACCESS 8
'X4'' FIRE PIT AT }18` WITH POURED IN PLACE LIGHT BROOM
DOORIDRAWER COMBO, LED FLEX LIGHT, STUCCO —� FINISH COLORED CONCRETE CAP, 2"1 BLACK LAVA ROCK UNITE
AND PAINT EXTERIOR TO MATCH ARCHITECTURE D TEND.AmP MEDIA, GAS VALVE AND KEY, BURNER ASSEMBLY, STUCCO NDEPENDRNNPP Yes
:ze+ AND PAINT EXTERIOR TO MATCH ARCHITECTURE L VF6FAr _ M18 C ELLAN EO US
PING CONCRETE µLgTyyBG
rye R. E-GEEBIEEL •18.8PA IRFLLI
�yE OWNER RESPONSIBILITIES UDN
NTO
15" WIDE POURED IN PLACE LIGHT BROOM FINISH Dp MWETTWPRGM.NTSELErnTGrvaF KAS SA 9CYTO rGFEOFvnnpl. A
COLORED CONCRETE COPING AROUND POOL -1" '-0' GLaI(ENeUECErw.rPW NN EaEPMRrt LournxsnvESI,E,EmtorccEP* -d/
PMNGOfl+PATMFM wTMEPME[f K6UNKEKPFAM i.
24'-C B,7 ry AARWWNCGEGERM PNF1L nTLE08TiWIfE pA0.YFpi6fl'EN WY6AFi[A I6TNLEp.
\a'�G.s MAIN HOUSE 200 AMP PANEL I+AQRE6mnTTEEERRe sxoTREEPpxmeLEFaquM>ERDRpuxocpxwnoxsoaoe,ems.
NpµYQF YNQNCNAB AEWµYSpNVE G UWN9 gimnERIA IN11l AfCE6GKFA.
POOL SPLIT MAIN DRAIN SUCTION MINIMUMS'APART. �"a INNU q>yMNTpxGlmµ�Ipaµwewais NFyTLGc.LCGpm Fan.FwLGKLowRE
ANTI -COVERS IO" ASME I ANSI APPROVED IM MPWLMMFAARY NTERPwTSe.IFGLLow nemucmpru-wNmusERBE6Eflnmel
t4'-O SB. I1)TNGE NGTI TINT Mp JGGGP ETxE I10L GNOPL +BFEIUN NF TEAT1Irus 11F)vr
"4 GAS VALVE 112' -17z" POLYPROPYLENE GAS PIPE TTEx FEAA,.MCNCPTEOBA.GFRMGREC
PAVER DECKING BY OTHERS wPmPE PE.N,PwL.EOEw�Pw',m,oc,*pNa.npll.eEW,IEEEFEooxPG,meE.EEEG D• a AnaEss DATE
A CUSTOM PROJECT FOR:
PAVER DECK DRAINS BY OTHERS 1z^wD 27 -°F\B. / J1 ME GRIFFIN RANCH LOT 255
-3 - .tB• �` °`8—`"`-0'v4—� •� Of MMUNITYGRIFFIN RANCH
5-D'wD G,n,wD UPS J BADDRESS 54-465 SEA' HERD CIRCLE ICITY LA DUINTA o
1T-7'S H' MEOWNER MOBILE
MEOWNER EMAIL '
POOLISPAUGHT UNCTIONBOX P WECTMANAGER MOBILE p6G 3541499
-10 POOL.I SPA LIGHT N GROUND FA T IRCUIT INTERRUPTER P OIECTMANAGER EMAIL aeon Immre.mm
TRANSFORMER 6ME DATE DESIGNED BY PROJECT MGR CHECKED BY
opw
9'-01SB. SPA AIR LINE I,. "=I' 05/09/19 JT. TANS, H.
BG REVISIONS �i
DATE:
SB. 1SAIETV FEATURES: _
t0B'-10"
TANNING SHELF AT 12" WATER DEPTH
AND ONE UMBRELLA SLEEVE
INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH
SECTION 114 - MANDATORY REQUIREMENTS
EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS
TO THE POOL
POOL HEATERS / PUMP EQUIPMENT SHALL BE INSTALLED PER MANU FAC
RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS
ALL DECKING EXPANSION JOINTS FOR REPRESENTAION ONLY,
FIELD LAYOUT WILL VARY
SPA SPLIT MAIN DRAIN SUCTION MINIMUM TAPART.
ANTI -COVERS IW ASME / ANSI APPROVED
RAISED SPA AT+18" WITH POURED IN PLACE LIGHT BROOM
FINISH COLORED CONCRETE CAP, STACKED STONE SPILLWAY
AND TILE VENEER EXTERIOR, (6) HYDRO THERAPY JETS AT
ALTERNATE HEIGHTS
SEA HERO CIRCLE
ELECTRICAL:
EGUIP°TENTIAL SLATING REQUIREMENTS SHALL BEIN.rANFU TO EUMWATE VOLTAGE
GMDIENTENTHEPOOLAREAAGPERCEGPRT. NNGN
01 6 CALIFDRNIA BUILDING CODE(BA%OONMTIIEBC) -
D16. CAL I FCRNIA MECHANICAL CODE OWEOCN=UMC)
016 CALIFORNIA PLUMBING CODE IRIOEDONO NUPC)"..a.
❑16'CALIFORNIA ELECTRICAL CODE (MSEDONoCa REP)
01 6''CALWORNIA ENERGY' EFFICIENCY STANDARDS
INSTRUCTION AUTHORIZATI❑
SALES FIELD
_GUNlTql
ELECTIONS